Anda di halaman 1dari 4

www.pcd- owmeter.

com

we measure the facts


Inline Flow Meters for Liquid Measurement
1 GAS FLOW METER

Thermal Mass Flow Meter Series


IC-LPM Brochure 2015/1
www.pcd- owmeter.com

1 Types

INTEGRAL OR REMOTE INSTALLATION

Description
Our Thermal mass ow meter is a standard solution optimal for various gas ow applications. This is specially designed for
applications with temperatures up to 150 °C. Both of the thermal gas ow series works on the anemometric principle
and consists of two platinum resistors on one chip which is immersed in a ow channel- a small resistance which is
which is immersed in a ow channel- a small resistance which is used as heater and a high resistance which is used
for the measuring of the gas temperature. The anemometric principle is based on a function of the ow speed and
utilizes heat transfer principles to determine the ow velocity. The heater is set to a constant temperature di erence
above the ambient temperature detected by the temperature sensor.

THEMAL MASS FLOW METER WITH FLOW INDICATOR


TOTALIZER AND TRANSMITTERS
Type : PCD-TMF-IL
Rugged Die cast aluminum Enclouser
Power Supply : 24 VDC / 230 VAC
2-line, 12-character LCD display
Total / accumulated total / ow rate
Integral or remote installation
Voltage input
RS 485 MODUS (Option)
4-20 mA output
SIZE: DN 15 UP TO DN 200

LOW FLOW THEMAL MASS FLOW METER WITH


FLOW INDICATOR TOTALIZER AND TRANSMITTERS
Type : PCD-TMF-LF
Rugged Die cast aluminum Enclouser
Power Supply : 24 VDC / 230 VAC
2-line, 12-character LCD display
Total / accumulated total / ow rate
Integral or remote installation
Voltage input
RS 485 MODUS (Option)
4-20 mA output
SIZE: 1/8 UP TO 1/2

PANEL MOUNT FLOW INDICATOR


AND TOTALIZER
Type : PCD-PMI-100
Enclosure : weather Proof
Dimensions : 96 X 96 X 130 Mm
Input Supply : 230 VAC / 50 Hz
Display : 0.36 , 7 Segment, Red LED / 16 X 2 LCD
Input : 4-20 mA, Optically Isolated, Pulse
Mounting : Panel Cutout with Fastening Clamps
www.pcd- owmeter.com
Speci cation

THE PCD THERMAL MASS FLOW METERS

Nominal size Dn15, DN20, DN25, DN40, DN80, DN100, DN150

Process connection BSP threaded, DIN & ANSI fanged; other on request eg
ti-clamp, NPT

Flange rating PN 16, 40, 100 (BS EN 1092-1); ANSI 150, 300, 600 RF (ANSI B16.5)

Compatibility Air, Oxygen, Nitrogen, Argon, Hydrogen, Natural Gas, LPG gas, Bio Gas, Compressed Air,
Co2 Gas, Ammonia, Ethane, Helium, Methene

Flow range 0 to 3356 M3/HR

Operating temperature Standard: -40 to 150 C

Max operating pressure All threaded bodies: up to 15 bar


Flanged bodies: depends on ange rating and operating temperature range
Higher pressure rating on request

OutPut 3.5 to 10 Volt

Pressure drop Very low (in term of water column)

Accuracy Better Than ± 2 % FSD

Repeatability ±0.5% of reading

Materials Body: 304 stainless steel (standard); 316 (optional); other materials available on request
Sensor Platinum Winding encapluted in SS316L
Enclosure Die-cast Aluminum

Output/display Analogue output , 4-20 mA , RS 485 on request

Installation Horizontal or Vertical ow

Approvals PESO Certi ed to gas group IIA, IIB

Features
SCFM, NM3/hr, Lbs/hr, Kg/hr and more
Dirt Insensitive
No Moving Parts
Ease of Installation
Negligible pressure drop
Wide turndown capability of 100 to 1
Economical solution for large diameters
Output both ow rate and temperaturesimultaneously
Accurate measurement and operation at very low gas pressures and ow rates
Measures mass ow directly - without additional Pressure and temperature inputs
Insertion and in-line models
we measure the facts

www.pcd- owmeter.com

Plot No. 22, Rautara Industrial Estate


Shil-Mahape Road,
Shil Phata, Thane 400 612
Maharashtra, India
+91 7666 298 298 / 86555 87403