Anda di halaman 1dari 5

Maintenance Panel Listrik

Diperiksa oleh: Fajar Ismoyo


Tanggal Pemeriksaan:
Nama Panel: Main Distribution Panel SDP 1

Diperiksa
Prosedur LOTO: oleh
1 Sumber Energi Dimatikan
2 Sarung Tangan Listik/Rubber Mat/Sepatu Listrik digunakan
3 instrument pengukur

No. Item Pekerjaan Sub Item Nilai


1 Pengukuran Tegangan R-S
S-T
R-T
R-N
S-N
T-N
2 Pengukuran arus beban R
S
T
N
Gnd
3 Pengukuran frekuensi R
S
T
4 Pengukuran temperature kabel R
S
T
N
5 Pengukuran Tahanan Kabel Grounding ke Body Panel Gnd-PEN
6 Pemeriksaan Fisik
Kunci Panel
Inner Cover Panel
Separator antar fasa pada breaker
Exhaust Fan Panel
Keadaan Panel
Bekas Terbakar
Baut/Cable Shoe/Lug
Peralatan indicator (Lampu Indikator, Analog Meter)
Gland Packing Kabel/Cable Duct
7 pembersihan debu/kotoran

Dilakukan oleh,
Electricians
Maintenance Panel Listrik Mingguan
PT. ESA MEDIKA M

Tanda Tangan

Limit Kondisi
380 V (-5%/+10%)
380 V (-5%/+10%)
380 V (-5%/+10%)
220 V (-5%/+10%)
220 V (-5%/+10%)
220 V (-5%/+10%)
Max 85% X In
Max 85% X In
Max 85% X In
Must be 0
Must be 0
50 Hz
50 Hz
50 Hz
< 65°C
< 65°C
< 65°C
< 65°C
< 5 Ohm
ingguan