WIRELESS INTELLIGENT SECURITY AND PROTECTION ALARM SYSTEM

SYSTEM USER MANUAL

In order to completely understand the functions of this system, please have a thorough reading of this manual

1
Table of Contents

1. MAIN FUNCTION AND FEATURES.....................................................................................................3

2. GUARD AREA SETTING.......................................................................................................................4

3. OPERATION METHOD.........................................................................................................................5

4. PIR MOTION DETECTOR INSTALLATION AND USE.........................................................................6

5. DOOR/WINDOW DETECTOR INSTALLATION AND USE...................................................................7

6. SYSTEM MAINTENANCE AND PROTECTION...................................................................................7

7. ENCODING AND DECODING METHOD OF WIRELESS DETECTORS............................................8

2
1. MAIN FUNCTION AND FEATURES

● DC 9V power supply, standby current less than 25mA


● Six groups of telephone numbers can be pre-stored
● 10 seconds pre-recorded memo message
● Remote distance (via telephone network) set arm status or disarm to the alarm system
● Remote distance (via telephone network) monitor the background sound around the alarm system
● Exit delay (arm system with delay) option (0-90 seconds selectable by user)
● Entrance delay (trigger alarm with delay) option (0-90 seconds selectable by user)
● Siren alarm time length control option (1-20 minutes selectable by user)
● Telephone line cut off alarm function option
● Fourteen wireless zones plus two wired zones, zone 2 to 5 can be closed or opened independently
● One emergency key for help is provided on the main unit
● Emergency key for help is provided on each remote controller which will trigger the alarm system
● Option to set whether give out siren sound or not, as well as auto-dial when being triggered.
● Convenient keypad is provided on the main panel
● 110dB siren speaker provided
● Various of door magnetic switch and motion infra-red detector are configurable
● Rechargeable DC9V backup battery provided for power cut backup

3
2. GUARD AREA SETTING

Alarm SC model is a sixteen-zone alarm panel. Its encoding method is listed below:

Encoding list:

Zone Zon e
N um b er Cod e Detectors Option Function
1 2212 Panic button with alarm voice Always guarding
2 2 211 PIR, door contacts, smoke and gas The zone can be
detectors etc. closed independently
3 2 12 1 As above As above
4 2112 As above As above
5 2111 As above As above
6 1 22 2 Panic button without alarm voice Always guarding
PIR, door contacts, smoke and gas
7 1221 detectors etc.
8 1 21 2 As above
9 1 211 As above
10 11 22 As above
11 11 2 1 As above
12 1112 As above
13 1111 As above
14 2 22 2 As above
15 Wired zone Normally closed
16 Wired zone Normally closed

4
3. OPERATION METHOD
Set full arm: You can press the key on the receiving phone to perform different commands as
Each guard zone can be configured with several door entry detectors, follow:
PIR sensors, gas leakage detectors, and smoke detectors. “1”: set arm “2”: set disarm
Full arm: Password + Press “Fullarm” button on panel “5”: turn on siren “6”: shut off siren
Disarm: Password + Press “Disarm” button on panel “7”: open background sound monitor
“8”: close background sound monitor
Zone 2 to 5 are part arm zones. They can be turned on or off as “9”: set diarm and auto-dialer hang up
follows: If you want to extend the monitor time, you can press the key “7” again
Part arm: Password + Press "Partarm" button on panel no longer than 20 seconds interval.
Disarm: Password + Press "Disarm" button on panel
Telecommunication setting by telephone:
Zone 1 is panic button zone with siren sound, and zone 6 is panic If you need to operate the alarm system far away, you can dial the alarm
button zone without siren sound. Both zones will trigger the alarm system by any other phone. After hearing eight times ring tone, the alarm
when received the panic button signal even under disarm state. system will automatically answer the phone. You can set the alarm system by
input numbers on the phone you used. At first, input four-digit password code
Zone 15 and Zone 16 are wired zones. There are short slips connecting on your phone no later than ten seconds. Then input the below number code
the two zone terminals on the back side of the main unit. Disconnecting as operation command:
the slips will trigger the alarm. “1”: arm the alarm system “2”: disarm the alarm system
“3”: setting alarm with sound “4”: setting alarm with no sound
Emergency alarm function : “5”: startup the horn “6”: shut off the siren
For any emergency event, you can press the emergency key or panic “7”: open background monitor “8”: close background monitor
button, and the system will immediately put into emergency alarm state. “9”: exit setting and hook on
If you press the emergency key on the remote controller, the system's If you want to extend the monitor time, you can press the key “7” again
siren speaker will give out loud sound as well as dial out the pre-stored no longer than 20 seconds interval. If no key is pressed more than 10
telephone number. If you press the emergency key “S” on the remote seconds, the alarm system auto-dialer will hang up automatically.
controller, the system's siren speaker will not give out loud sound but
dial out the pre-stored telephone number as usual. Alarm system setting method :
1. Store alarm telephone number, press:
Alarm process: “password+sto” + “group number (1~6)” + “ * ” + phone number + “sto”
When alarm is triggered, the siren will hoot (if siren on option is selected). The 2. Cancel alarm telephone number, press:
system will automatically dial out the pre-stored telephone number and send “password+sto” + “group number (1~6)” + “ * ” + “sto”
pre-recorded alert message to the receiving phone. 3. Alarm memo recording, press:
“password+rec” + speak memo message to mic + “rec”
5
Press “password+rec” and release, you can hear a beep sound. You can “password+pro” + “5” + “pro” + “time (0~90sec)” + “pro”, setting arm
start recording, speaking time no more than 10 seconds. The MIC is status with delay time can be set to range between 0~90 seconds.
located on one side of the alarm unit. When finished, press the “rec” 9. Trigger alarm with delay time option, press:
again. You can hear two beeps to indicate the completion of the recording “ password+pro” + “6” + “pro” + “time (0~90sec)” + “pro”, trigger
process. alarm with delay time can be set to range between 0~90 seconds.
4. Setting alarm with siren sound, press: 10. Turn on telephone line cut-off detect function, press:
“password+pro” + “1”, the siren will give sound when alarm is triggered.
“password+pro” + “7”, this function will trigger the alarm and make the
5. Setting alarm with no siren sound, press:
“password+pro” + “2”, the siren will not give sound when alarm is triggered. siren hoot when alarm telephone line is cut off.
6. Alarm siren hooting time option, press: 11. Turn off telephone line cut-off detect function, press:
“password+pro” + “3” + “pro” + “time (1~20min)” + “pro”, the siren “password+pro” + “8”, this function will NOT trigger the alarm and will
hooting time can be set to range between 1~20 minutes. NOT make the siren hoot when alarm telephone line is cut off.
7. Clear all settings, press: 12. Modify main unit password, press:
“password+pro” + “4”, this function clear all settings including pre-stored
“password+pro” + “9” + “pro” + “four-digit password” + “pro”, this four
telephone numbers. All settings will be restored to its initial setting as it was
first manufactured out. digit password is used in main unit operation and phone operation. The default
8. Setting arm status with delay time option, press: password is “1234”.

4. PIR MOTION DETECTOR INSTALLATION AND USE

To power up, turn on the power switch on the side of the detector. Mounting height should adjust to about 2.2m. Mounting the detector at the corner of
the room is preferable and setting its detecting direction perpendicular to the people walking direction will give the best effect.

Mounting method: take out the bracket in the accessories pack and fix it on your wall. Fix the detector to the bracket and adjust its detection angle to
the best position.

The following aspects should be noted:


1. The infrared detector should not face the outward window.
2. Obstacles on its front have negative effect.
3. More than two infrared detectors should not be installed in the same area.
4. Strong wind flow, fire, radiator should be avoided, for it may make the detector give false alarm.
5. When the infrared detector powered up, it will take five minutes to adapt itself to normal working mode.
6. The infrared detector can only be used in closed room, not be used in open ground.

6
5. DOOR/WINDOW DETECTOR INSTALLATION AND USE

1. The emitter of door entry detector is mounted on the edge of movable door, and the magnetic bar is
mounted on the fixed doorframe. The two pieces of devices must be no more than lcm distance when the
door is closed.
2. The magnetic bar must be installed near to the emitter side of LED indicator.
3. When the door is opened from the closed position, the emitter's upper LED indicator will light up for one
second. This means the door entry detector works well .
4. The upper LED indicates that it is sending alarm message to the main alarm unit, and the lower LED
indicates that the power supply has low battery.

6. SYSTEM MAINTENANCE AND PROTECTION

1. Avoid direct sunlight, excessive high or low temperature, and moist environment.
2. Avoid placing on unstable location.
3. Avoid liquid flowing into the device.
4. Do not use other power supply for substitution.
5. The battery of remote controller, PIR infrared detector, and door detector need to be replaced while they have low battery (the battery usually has
several month life time).

7
7. ENCODING AND DECODING METHOD OF WIRELESS DETECTORS

Encoding and decoding method of the wireless alarm system

This alarm system uses wireless transmission style to communicate with its
wireless detectors. To protect alarm systems from interfering each other, the
wireless signal can use different encoding style for different alarm systems. you
can add detectors to an alarm system by encoding the detectors.
Each alarm system has its unique wireless communication code. This includes
8-bit address code A0, A1, A2, A3, A4, A5, A6, A7, and 4-bit zone code (or data
code) D0, D1, D2, D3. Each set of alarm system has only one address code, but
can have several zone code. The address code is used for communications
between main unit and detectors only. We printed it out at the back side of the
alarm set and marked as "Serial No". The zone code is used to group different
detectors into different wireless alarm zones (SC model has 14 wireless zones
and 2 wired zones). For example, we have 16 LED indicators on the alarm main
unit. The “alarm 1” LED is corresponding to zone 1, the “alarm 2” LED is
corresponding to zone 2, the “alarm 3” LED is corresponding to zone 3, the
"alarm 4" LED is corresponding to zone 4, and so on.
We use the "short jumper slip" option to realize the encoding, you can use a
screw driver to take off the screw of the PIR motion sensor and open the cover.
On the power switch side of the electronic circuit board, you can see 36 metal
pins (12 rows with 3 pins on each row). This 36 metal pins are used to encode
the 8-bit address code and 4 bit zone code.

8
You can also open the emitter part of the door detector. There are If a pin in the middle row is not connected by a short jumper slip (or in
also 36 metal pins on the side of the electronic circuit board. This float state), we called the pin encoded as “0”. The 8 pins for address code
36 metal pin are also used to encode the 8-bit address code and 4-bit has three encoding state, “1”, “0”, and “2”. The 4 pins for zone code has
zone code. only two encoding state, “1”, “2”. Which means the 4-bit zone code must
have jumper slips connecting from middle row pins to either H or L row
pins, and cannot has float state “0”.

There are total 3 rows of pins. Each row has 13 pins. The 13 pins in
the top row near the IC SC2262 (or HS 2262, or PT2262) is high
electric level, marked by H. The 12 pins in the bottom row near the
side of the electric circuit board is low electric level, marked by L.
The 13 pins in the middle row is to be set by short jumper slip. If a pin
in the middle row is connected by a short jumper slip to the H row pin,
we called the pin encoded as “1”. If a pin in the middle row is connected
by a short jumper slip to the L row pin, we called the pin encoded as “2”.
9
Figure below shows the 8-bit address code in the middle row is Figure below shows the 8-bit address code in the middle row is
“21120102”, the 4-bit zone code is “2211” (zone2). “22212011”, the 4-bit zone code is “2112” (zone4).

Figure below shows the 8-bit address code in the middle row is Figure below shows the 8-bit address code in the middle row is
“11100222”, the 4-bit zone code is “2121” (zone3). “11011220”, the 4-bit zone code is “2111” (zone5).

Figure below shows the 8-bit address code in the middle row is If you want to add detector to your alarm set, there will be two method,
“12202011”, the 4-bit zone code is “2112” (zone4). the first method is to configure the detectors according to the short jumper
slip setting exactly the same as the detectors programmed in your
standard kit. The second method is you set the 8-bit address for the
detector accordingly to the “Serial No.” at the back of your alarm main
unit, and encode the 4-bit zone code following the encoding list on P.4.

10
The wireless smoke detector and gas leakage detectors each has
a wireless emitting module inside the plastic cover. There are also 36
pins to set the 8-bit address code and 4-bit zone code on the
emitting module.
The 8-bit address code is at the bottom side, and the 4-bit zone
code is on the right side. The 8-bit address code is also the same as
infrared motion detectors for the same alarm set. But we can set the
4-bit zone code as 24 hours guard zone. Of course your can also set the
zone code as zone 1, 2, 3, 4, or other zones as you like. The 24 hours
guard zone will report alarm messages even if your alarm unit is in
disarm state.
A wireless emergency button is generally configured as 24 hours
guard zone in the same method.

The manufacturer reserves the right to change and modify the product design and specifications without notice.
All materials have been carefully checked to ensure accuracy.
This Company holds no responsibility for consequences caused by printing missing or translation errors on this manual.
Copyright 2010 ©