1) Be sure you have connected the CAT-5 cable correctly. Note that the
stripe/solid pattern should match the labels on the product. Miss-wiring can
cause distorted sound or prevent the system from working at all!
2) Be sure you have connected the speakers in phase. Follow the label on the
C HANNEL V ISION TM
product. Out of phase speakers can rob the system of its bass. Especially when TM
driving dual-voice-coil speakers.
3) Be sure IR emitters are directly over the IR receiver for all devices you wish to
system
control. AB-114 / AB-202
AB-404 / AB-301
Specifications: (typical @25º C) AB-T2454
Operating Voltage : 24±.5VDC
Status input: 9-20VDC <20mA
Multi-room audio
Cable requirements: CAT-5 or better distribution system
Speaker impedance: 6-8 ohm
IR repeating: 38-56kHz
IR sensor range (AB-114): 40’@40kHz 25’@56kHz IN OUT 1 2 3 4
BRN
WHT/BRM
CHANNEL VISION by
C HANNEL V ISION TM
AUDIO STATUS
Line level inputs 12VDC
Channel Vision Technology will repair or replace any defect in material or workmanship which L R
occurs during normal use of this product with new or rebuilt parts, free of charge in the USA, for
two years from the date of original purchase. This is a no hassle warranty with no mail in By C HANNEL V ISION TM
STATUS
warranty card needed. This warranty does not cover damages in shipment, failures caused by AB-202 IR
A-BUS OUTPUT IR EMITTERS
other products not supplied by Channel Vision Technology, or failures due to accident, misuse,
abuse, or alteration of the equipment. This warranty is extended only to the original purchaser,
and a purchase receipt, invoice, or other proof of original purchase date will be required before
warranty repairs are provided.
Mail in service can be obtained during the warranty period by calling (800) 840-0288 toll free.
A Return Authorization number must be obtained in advance and can be marked on the outside
of the shipping carton.
This warranty gives you specific legal rights and you may have other rights (which vary from
C HANNEL V ISION TM
state to state). If a problem with this product develops during or after the warranty period, please
contact Channel Vision Technology, your dealer or any factory-authorized service center. 234 Fischer Avenue · Costa Mesa, CA 92626
(714) 424-6500 · (800) 840-0288 · (714) 424-6510 fax
www.channelvision.com · email: sales @ channelvision.com
500-012 rev J1
© 2004 Channel Vision Technology
The Channel Vision A-BUS system
can distribute high-quality audio to every room in your house over Balance ... The two potentiometers on the AB-
ordinary CAT5 data wire. Power for the entire system is delivered via 114 adjust the volume levels of each speaker
the same CAT5 cable so only a single run of CAT5 is required. Each channel. Use these to adjust the speaker
pair of speakers is powered and controlled from a local wall plate with balance in this zone.
a dedicated amplifier for that zone. Volume in that zone can be
controlled manually or by an infrared remote. IR signals are also
routed back to the source components enabling control of sources and Gasket ... The AB-114 is
functions from any zone. shipped with a gasket. This
allows you to adjust the height
Required components and fit of a decorator trim plate.
Leave the gasket as is for a
AUDIO STATUS
flush fit. Remove the gasket to
12VDC
L R
AB-202 ... Single source module. 1 per have the AB-114 stand above
system. Interfaces sources to the the plate.
By C HANNEL V ISION TM
system. Mount near audio components
AB-202
STATUS
IR
(CD player, receiver etc.)
A-BUS OUTPUT IR EMITTERS
Input/Output ... To simplify
installation, the AB-301 has both 110
IN OUT and RJ-45 inputs and outputs. Only
IN OUT 1 2 3 4 AB-404 ... Distribution module. 1 per one of the inputs and one of the
BRN
WHT/BRM
BLU every 4 amplified keypads. All CAT-5 outputs should be used at a time.
WHT/BLU
GRN
WHT/GRN
ORG
cables terminate here. Also inserts
WHT/ORG
power. Mount in a structured wire panel
Gasket ... The AB-301 is
or screw to a wall. Compatible with
C HANNEL V ISION
shipped with a gasket. This
by TM
IR emitters
panels from Channel Vision CentralTM,
allows you to adjust the height
OpenHouseTM, OnQTM, or LevitonTM.
and fit of a decorator trim plate. Line level inputs
Power
Select
Learn
Tuner
Rew<<
VCR
Channel Vision
4
7
1
Comes pre-programmed to control the
AB-500
AB-404
Tx Batt
Play>
Stop
DVD
CD
Ch
5
0
2
volume of the AB-114. Learns IR codes for
Learn Error
Pause
All Off
FF>>
-/--
TV
Vol
Off
Sat
6
9
3
TM
IN OUT 1 2 3 4
up to 6 sources.
BRN
WHT/BRM
BLU
WHT/BLU
GRN
WHT/GRN
ORG AB-114 IR-3001 & IR-3002 ... Single and dual
head IR flashers. Use one head per
WHT/ORG
Follow the
by
C HANNEL V ISION TM
AB-202
STATUS
IR
The top LED flashes as IR
A-BUS OUTPUT IR EMITTERS information is received.
Point any
Option ... To add more zones, connect slave IR remote control
AB-404s as shown. Each AB-404 requires a at the AB-114
separate power supply (AB-T2454) and will
support another four keypads. You may have Re
w<
<
Tx
Ba
7 5 3
Po
we
r 8 6
0 9
Ch -/-
-
Vo
IN OUT 1 2 3 4 IN OUT 1 2 3 4 l
BRN
WHT/BRM
BLU
BRN
WHT/BRM
BLU VC
R
Tu
ne
r
Se
le
ct
CD
Al
Le
l Of
f
ar
n
Er
ro
r
CD player
Of
1 Loop out ... Use this to expand to an additional AB-404. IR emitters IR emitters
GRN
WHT/GRN
ORG Line level inputs
WHT/ORG
by
C HANNEL V ISION TM
music a part of your house. Line level inputs Line level inputs Line level inputs
4 9
Advanced system
Sat radio
Using the AB-301 as a universal input module Inputs ... IR-3001 flasher placed over
DVD player IR receiver on all sources. (IR option).
Connect audio L/R on the AB-202 to
In this system the tape monitor output of the receiver.
CD player Plug 5019 power supply into switched
The first AB-301 1 is used to input the main audio
the AC outlet on the receiver. (Status
source. The second AB-301 2 is used to input audio
option.)
from a paging system. The AB-301 in each room 3 is
used to input audio that will only be heard in that room’s Receiver
speakers.
Using the IR option, you can control the components from
Optional
any room. You can change the system input from FM to
AB-202
the CD player, select another satellite radio station, or
pause the CD. L
AUDIO
R
STATUS
12VDC
Room 4
AB-T2454
The AB-301 is activated by audio. The system mutes and power supply
conserves power whenever there is no audio feeding AB- By C HANNEL V ISION TM
STATUS
by
C HANNEL V ISION TM
AB-114 Room 1
3
8 5
Advanced system Each room can listen to a different local source.
The RCA inputs on the AB-301 will override the main input
Using the AB-301 as a local source input module source, allowing each room to listen to a different local
source.
DVD player
IR emitters
Room 4
CD player Line level inputs
AUDIO STATUS
L R 12VDC
AB-202
Receiver
By C HANNEL V ISION TM
AB-202
STATUS
IR AB-T2454
IR EMITTERS
A-BUS OUTPUT
power supply
IN OUT 1 2 3 4
BRN
WHT/BRM
BLU
IR emitters
Room 3
WHT/BLU
AB-404 GRN
WHT/GRN
ORG
WHT/ORG
AB-301
IN OUT
IR emitters
Room 2
OUT
IR emitters
AB-114
6 7