GIL 3.06.00
Additional elements
GHL Top-hung 3.02.04
roof window
GIU 3.06.02
Additional elements
A R C H I T E C T 3.00.00
012005 © 2005 VELUX Group
GIR
A R C H I T E C T 3.00.01
012005 © 2005 VELUX Group
VELUX roof windows
Exterior cladding
As standard the window is supplied with
maintenance-free exterior cladding of grey
aluminium. The grey colour has colour code
NCS S-7500-N, making it easy to fit in
with different colours and types of roofing
materials. The colour has also been selected
to obtain harmony, even under very different
light conditions, between the grey cladding
and the window glass. One of the reasons
why NCS (Natural Color System) has been
selected is that the colours in this system
do not contain environmentally damaging
pigments.
Barrel bolt
VELUX roof windows can be fully rotated
and securely locked with the barrel bolt for
easy cleaning of the exterior pane.
In addition, the centre-pivot roof windows
can be secured in open position.
A R C H I T E C T 3.00.02
012005 © 2005 VELUX Group
GGL Centre-pivot
roof window
Centre-pivot window
Application
GGL roof window can be installed in
roof pitches between 15° and 90°.
For easy operation and free view
it is recommended to place the top
frame of the window 1.85 – 2.20m
above the floor.
Features
GGL versions
The centre-pivot window features a
control bar which, when operated, Standard Variants
opens the ventilation flap. The friction
hinges keep the window in an open Frame
Nordic pine with TOPfinishTM White paint, PAINTfinishTM
position, and if additional ventilation and sash
is required it can be opened further
and secured with a barrel bolt.
Exterior Titanium zinc, pre-patinated zinc,
Operation Grey aluminium
cladding copper or other cladding colours
GGL window is operated by means
of the control bar at the top of the
window sash. The control bar is used
Standard insulating (--00)
for opening of the ventilation flap and Panes PROTEC-STARTM (--73)
See section 8
the window.
The window can be opened
approx. 5° and locked for ventilation.
GGL can be combined with:
The sash can also be fully
rotated and locked for easy cleaning Flashings for Exterior sunscreening
of the exterior of the pane. • Single installation • Awning blind
• Twin installation • Roller shutter
• Combi installation
A R C H I T E C T 3.01.00
012005 © 2005 VELUX Group
Technical data GGL
P25
Sizes
Pane
62
GGL GGL variant C01 C02 C04 F04 F06 M04 M06 M08 M10 M12 P04 P06
70
C02
GGL GGL GGL GGL GGL
Ventilation open window --00 0.27 0.31 0.40 0.50 0.61 0.60 0.74 0.89 1.03 1.17 0.74 0.91
98
[m2] --73
C04 F04 M04 P04 U04
GGL GGL GGL GGL
--00
Effective daylight area [m2] 0.17 0.20 0.27 0.35 0.45 0.44 0.56 0.69 0.82 0.94 0.56 0.71
118
--73
F06 M06 P06 S06
GGL GGL GGL GGL
Sizes
140
Pane
variant P08 P10 P25 S01 S06 S08 S10 U04 U08 U10
M08 P08 S08 U08
GGL GGL GGL GGL
Ventilation flap --00 5 5 5 6.2 6.2 6.2 6.2 7.4 7.4 7.4
[103 mm2] --73
160
--00
Effective daylight area [m2] 0.88 1.03 0.23 0.43 0.90 1.11 1.30 0.85 1.34 1.57
--73
M12
cm 55 66 78 94 114 134
--00 Class 2
12.5 Air permeability EN 12207
30 --73 Class 3
147
Light transmittance, τ v --00 0.76 EN 410
--73 0.75
f I H
Exterior Visible Lining
Measurements [mm]: frame
dimension
glass rebate
100.5
Exterior Visible Lining Size H f l
frame glass rebate
29 dimension P25 550 302 491
Height
A R C H I T E C T 3.01.01
012005 © 2005 VELUX Group
GGU Centre-pivot
roof window
Application
GGU roof window can be installed
in roof pitches between 15° and 90°
with the recommended installation
height the same as the GGL. The
elegant white polyurethane window is
resistant to humidity and condensation GGU versions
making it particulary suited for use in
Standard Variants
a kitchen or bathroom.
A R C H I T E C T 3.01.02
012005 © 2005 VELUX Group
Technical data GGU
C02 Pane
GGU GGU GGU
variant C02 CO4 F06 M04 M06 M08 P06 P08 S06 S08
98
--34
C04 F04 M04 Ventilation flap
GGU GGU GGU GGU --59 2.7 2.7 3.4 4 4 4 5 5 6,2 6.2
[103 mm2] --73
118
--34
F06 M06 P06 S06 Ventilation open window
GGU GGU GGU
--59 0.31 0.40 0.61 0.60 0.74 0.89 0.91 1.10 1.12 1.35
[m2] --73
140
--34
Effective daylight area [m2] --59 0.20 0.27 0.45 0.44 0.56 0.69 0.71 0.88 0.90 1.11
M08 P08 S08
--73
160
Size H f l
100.5
C02 778 530 719
Height
A R C H I T E C T 3.01.03
012005 © 2005 VELUX Group
GPL Emergency escape/
access roof window
Top-hung
roof window
Application
GPL roof window can be installed in
roof pitches between 15° and 55°
(with special springs up to 75°).
Certain sizes of GPL window
meet the Building Regulations for
emergency escape/access. For
further details see 2.10.00. GPL versions
Emergency escape/access roof
windows should not be fitted with Standard Variants
locks, restrictors, shutters or any other
product that will restrict their use. Frame
Nordic pine with TOPfinishTM White PAINTfinishTM
and sash
Features
Top-hung window with control bar,
ventilation flap with air filter, opens in Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
various positions up to 45°. Barrel cladding copper or other cladding colours
bolt for keeping the window locked in
cleaning position. The handle at the
bottom sash can keep the window in
THERMO-STARTM (--59)
ventilation position. Panes PROTEC-STARTM (--73)
See section 8
Operation
The window is opened by means of
GPL can be combined with:
a handle placed at the bottom sash.
The control bar at the top of the Flashings for Exterior sunscreening
window sash is used for opening the • Single installation • Awning blind
• Twin installation • Roller shutter
ventilation flap or for fully rotating the • Combi installation
sash for cleaning of the exterior pane.
A R C H I T E C T 3.02.00
012005 © 2005 VELUX Group
Technical data GPL
Pane
variant M06 M08 M10 P06 P08 P10 S06 S08 S10 U08
98
--59
Effective daylight area [m2] 0.56 0.69 0.82 0.71 0.88 1.03 0.90 1.11 1.3 1.34
M08 P08 S08 U08
--73
GPL GPL GPL
160
--59 32
Sound insulation, Rw [dB] EN ISO 140-3/EN ISO 717-1
180
--73 35
--59
cm 55 66 78 94 114 134
Air permeability --73 Class 3 EN 12207
27.5 k
f I H
W Size H f l
M06,P06,S06 1178 930 1119
Height
100.5 M08,P08,S08,
U08 1398 1150 1339
29 M10,P10,S10 1600 1352 1541
A R C H I T E C T 3.02.01
012005 © 2005 VELUX Group
GPU Top-hung
roof window
Application
GPU roof window can be installed
in roof pitches between 15° and 55°
(with special springs up to 75°).
The maintenance free poly-
urethane surface makes the window
resistant to humidity and condensation. GPU versions
It is therefore ideal for kitchens,
Standard Variants
bathrooms, shower rooms, etc.
Some sizes of GPU meet
Frame EVERfinish® - white varnished
Building Regulation requirements for
and sash polyurethane with wooden core
emergency escape/access. Please
refer to 2.10.00 for further details.
Emergency escape/access roof
windows should not be fitted with Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
locks, restrictors, shutters or any other
product that will restrict their use.
A R C H I T E C T 3.02.02
012005 © 2005 VELUX Group
Technical data GPU
Sizes
78
Pane
variant
GPU GPU F06 M06 M08 P06 P08 S06 S08
98
--34
C04 M04 Ventilation flap
GPU GPU GPU GPU --59 3.4 4 4 5 5 6.2 6.2
[103 mm2] --73
118
--34
F06 M06 P06 S06 Ventilation open window
GPU GPU GPU --59 0.63 0.76 0.91 0.94 1.13 1.15 1.39
[m2] --73
140
--34
Effective daylight area [m2]
--59 0.45 0.56 0.69 0.71 0.88 0.90 1.11
M08 P08 S08
GPU GPU --73
160
--34
Thermal transmittance, --59 1.6
M10 P10 pr EN ISO 12567-2
Uw [W/m2K] --73
--34 32
180
f I H 27.5 k
W Size H f l
Height
F06,M06,P06,
100.5 S06 1178 930 1119
M08,P08,S08 1398 1150 1339
29
A R C H I T E C T 3.02.03
012005 © 2005 VELUX Group
GHL Top-hung
roof window
Top-hung
roof window
Application
GHL roof window can be installed in
roof pitches between 15° and 55°
(with special springs up to 75°).
The bottom edge of the window
must be placed approx. 0.90 – 1.20m
above the floor.
GHL versions
Features
Top-hung window with control bar, Standard Variants
ventilation flap with air filter, three
different opening positions, 5°, 15° Frame
Nordic pine with TOPfinishTM White paint, PAINTfinishTM
and 30°, barrel bolt for keeping the and sash
window locked in cleaning position,
handle at the bottom sash can keep
the window locked in ventilation Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
position. cladding copper or other cladding colours
Operation
The window is opened by means of
THERMO-STARTM (--59)
a handle placed at the bottom sash. Panes PROTEC-STARTM (--73)
See section 8
The control bar at the top of the
window sash is used for opening
the ventilation flap or for fully rotating
GHL can be combined with:
the sash for cleaning of the exterior
pane. Flashings for Exterior sunscreening
• Single installation • Awning blind
• Twin installation • Roller shutter
• Combi installation
A R C H I T E C T 3.02.04
012005 © 2005 VELUX Group
Technical data GHL
Pane
GHL GHL GHL GHL variant C04 F06 M04 M06 M08 P04 S06 S08 U04
98
--59
Effective daylight area [m2] 0.27 0.45 0.44 0.56 0.69 0.56 0.90 1.11 0.85
M08 S08 --73
160
--59 32
180
--59
cm 55 66 78 94 114 134 Air permeability Class 3 EN 12207
--73
VELUX GB/IRL product programme
Light transmittance, τ v --59 0.76 EN 410
--73 0.75
Measurements [mm]:
Cross-sections and measurements
Exterior Visible Lining
frame glass groove
168 dimension
Size W e k
12.5 30
Width
f I H 27.5 k
W
Size H f l
C04,M04,U04 978 730 919
Height
100.5
F06,M06,S06 1178 930 1119
M08,S08 1398 1150 1339
29
A R C H I T E C T 3.02.05
012005 © 2005 VELUX Group
GEL + VEA/B/C
Roof Terrace System
Application
The VELUX Roof Terrace System can
be installed in roof pitches between
35° and 53°. The system offers the
possibility of creating a roof terrace
with access from the building. The
number of units installed is according
to individual wishes. VELUX do not
supply the exterior terrace weathering GEL+VEA/B/C versions
or railing elements.
Standard Variants
Features
The system consists of: Frame
Nordic pine with TOPfinishTM White paint, PAINTfinishTM
GEL: The top-hung top element opens and sash
45°, barrel bolt for locking the sash in
cleaning position, ventilation flap with
air filter, control bar. Exterior Titanium zinc, pre-patinated zinc,
VEA: Side-hung bottom element Grey aluminium
cladding copper or other cladding colours
opens 90° and is hinged on the left
hand side seen from the outside.
VEB: Side-hung bottom element opens
90° and is hinged on the right hand Panes PROTEC-STARTM (--73) See section 8
side seen from the outside.
VEC: Fixed bottom element.
The appropriate flashing and the EBY
adjustable support trimmer are also Roof Terrace System can be combined with:
supplied as part of the system.
Flashings for Interior sunscreening
• Combi installation • Siesta blinds
Operation
• Roller blinds
GEL can be opened by means of • Pleated blinds
a handle at the bottom sash. The • Venetian blinds
window opens up to 45°.
The control bar on GEL is used
for operating the ventilation flap or for Linings for Exterior sunscreening
fully rotating the sash for cleaning the • Specially made on request • Awning blind
- please contact VELUX - for top element GEL only
exterior pane.
The bottom element is opened
by means of a handle at the side
sash. When both the top and the
bottom element are open, there is
free access to the roof terrace.
A R C H I T E C T 3.03.00
012005 © 2005 VELUX Group
Technical data GEL + VEA/B/C
Roof Terrace System
Ventilation flap
--73 4 –
[103 mm2]
VEC M35 VEC M35
VEA M35 FIXED FIXED VEB M35
109
Right hand
outward
opening Light transmittance, τ v --73 0.75 EN 410
238
Total solar energy
--73 0.54 EN 410
VELUX GB/IRL product packages transmittance, g
Cross-sections and 7
14
measurements 6
6
13
50
11
147
603
69 GEL
696
725 27,5
GEL
780
63
147
1093
1049
930
603
VEA
56
696
15
VEA 725
VEB
VEB VEC
44
780
VEC
A R C H I T E C T 3.03.01
012005 © 2005 VELUX Group
GDL CABRIO™ Roof
Window Balcony System
Application
The GDL CABRIO Roof Balcony
window can be used on its own
in roof pitches 35° and 53°.
It can also be used, to great effect,
in conjunction with a combination
comprising GPL top-hung and GIL
fixed lower window elements. Further GDL versions
combinations are also available.
Standard Variants
Features
The GDL upper sash and GPL can Frame
Nordic pine with TOPfinishTM White paint, PAINTfinishTM
open up to 45° and have control and sash
bars, ventilation flaps with air filters
and barrel bolts to secure the sash
when reversed for cleaning. The GDL Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
bottom sash has integral railings cladding copper or other cladding colours
which automatically slide into place.
Operation
Comprising of GDL, GPL and GIL roof Panes PROTEC-STARTM (--73) See section 8
windows, the system retains all the
functions of a VELUX roof window.
The GDL CABRIO balcony opens and
closes easily on powerful, spring The CABRIO Roof Window Balcony System can be combined with:
assisted hinges.
Flashings for Interior sunscreening
GDL CABRIO upper element
• Single installation • Siesta blinds
and GPL are opened by means of a • Combi installation • Roller blinds
handle on the bottom of the sash. • Pleated blinds
The control bar at the top of the sash • Venetian blinds
is used to open the ventilation flap or
to fully rotate the window into the
cleaning position. When pushed Linings for Exterior sunscreening
gently forward into the vertical • Roof • Awning blind
– only for top element.
position the lower section of the
GDL forms an instant balcony with
side railings. GIL is a fixed window
element which fits directly below Additional accessories
the GPL. • Insect screen
A R C H I T E C T 3.04.00
012005 © 2005 VELUX Group
Technical data CABRIO™
Roof Window Balcony System
[103 mm2]
Top hung
GDL GPL
CABRIO P10 Thermal transmittance,
--73 1.6 pr EN ISO 12567-2
252
Uw [W/m2K]
Fixed
Available in Sound insulation, Rw [dB] --73 35 EN ISO 140-3/EN ISO 717-1
GIL
P34 sets including
flashings
198 Air permeability --73 Class 3 EN 12207
Fixed
GIL Fixed
P34 GIL
P34
302
Cross-sections and measurements
Vertical section Horizontal section, top element Horizontal section, bottom element
168
12.5 1022
30
147
49.3
233
1352
12.5 765
858
147
27.5 887
942
49.3
765
27.5 887
942
730
100.5
12.5
29
A R C H I T E C T 3.04.01
012005 © 2005 VELUX Group
GGL + VFE Combined roof and vertical
window element
Operation
VFE is operated by means of a handle
at the top of the sash. Ventilation is VFE can be combined with:
obtained through a limited opening
Roof windows Interior sunscreening
for safety. A release button makes it • GGL • Siesta blinds
possible to open the window completely • GHL • Roller blinds
for easy cleaning of the exterior pane. • GPL • Pleated blinds
• Venetian blinds
A R C H I T E C T 3.05.00
012005 © 2005 VELUX Group
Technical data VFE
GGL
variant M31 M34 P31 P34 S31 S34 U31 U34
118
140
118
M06 M08
M06 M08
VFE VFE
Ventilation open window [m2] --73 0.33 0.58 0.41 0.72 0.51 0.88 0.61 1.05
95
95
VFE VFE
60
60
GGL*
Measurements [mm]:
Exterior Visible Lining
frame glass groove
dimension
GGL*
11 Size W e k
Width
f I H
Size H f l
VFE 12.5 e
M31,P31,
Height
A R C H I T E C T 3.05.01
012005 © 2005 VELUX Group
VFA/B Vertical
window element
Application
VFA and VFB can be combined with
VELUX roof windows GGL, GHL and
GPL. It is the ideal solution for rooms
with a high inner wall where an
extended view is required.
The top of the frame is profiled VFA/B versions
so that it fits into the bottom frame of
Standard Variants
the roof window. Can be installed in
a roof pitch between 15° and 55°.
Frame
The vertical window elements Nordic pine with TOPfinishTM White paint, PAINTfinishTM
and sash
are delivered in standard widths.
Features
VFA vertical window element is left- Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
hung. VFB is right-hung. Both vertical
windows open inwards. Handle for
opening the window in tilting
position.
Panes PROTEC-STARTM (--73) See section 8
Operation
VFA and VFB are operated by means
of the handle at the side sash and
the window is opened to ventilation VFA/B can be combined with:
position. Roof windows Linings for
A release button makes it possible to • GGL • Roof and vertical elements
open the window up to 90°, and • GHL
thereby used as emergency esape. • GPL
Additional accessories
• Insect screen
A R C H I T E C T 3.05.02
012005 © 2005 VELUX Group
Technical data VFA/B
M34 P34 S34 M34 M36 M38 P34 P36 P38 S34 S36 S38
VFA VFA VFA
VFB VFB VFB
115
Effective daylight area [m2] 0.44 0.56 0.69 0.56 0.71 0.88 0.70 0.90 1.11
M36 P36 S36
VFA VFA VFA
VFB VFB VFB
Ventilation open window [m3] 0.56 0.70 0.87 0.70 0.89 1.07 0.86 1.09 1.32
137
Thermal transmittance,
Available to order 1.6 pr EN ISO 12567-2
U-value [W/m2K]
Size W e k
Width
26
A R C H I T E C T 3.05.03
012005 © 2005 VELUX Group
GIL
Additional elements
Application
GIL roof window can be installed in
roof pitches between 15° and 90°.
The window is installed directly
against the frame of the roof window
positioned above. The design of
the window gives new architectural GIL versions
possibilities and increases the field
Standard Variants
of vision downwards.
Frame
Features Nordic pine with TOPfinishTM White paint PAINTfinishTM
and sash
GIL roof window has a fixed sash.
Ventilation takes place through the
roof window positioned above.
Frame and sash are delivered with Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
the same inner and outer profiles as
the roof windows with which the
window is combined.
Interior sunscreening
• Siesta blind
• Roller blind
• Pleated blind
• Venetian blind
A R C H I T E C T 3.06.00
012005 © 2005 VELUX Group
Technical data GIL
Size W e k
Width
Size H f l
M34,P34,S34,U34 920 730 879
100.5
29
A R C H I T E C T 3.06.01
012005 © 2005 VELUX Group
GIU
Additional elements
Application
GIU roof window can be installed in
roof pitches between 15° and 90°.
The window is installed directly
against the frame of the roof window
positioned above. The design of the
window gives new architectural GIU versions
possibilities and increases the field
Standard Variants
of vision downwards.
Interior sunscreening
• Siesta blind
• Roller blind
• Pleated blind
• Venetian blind
A R C H I T E C T 3.06.02
012005 © 2005 VELUX Group
Technical data GIU
Size W e k
Width
27.5 k
Size H f l
Height
W
f I H
M34,P34,S34 920 729 879
100.5
29
A R C H I T E C T 3.06.03
012005 © 2005 VELUX Group
GIR
GI–
Additional elements
Application
GI- roof window can be installed in
all roofing materials in roof pitches
between 15° and 90°. The window
is installed directly against the frame
of the roof window positioned below.
The design of the window gives new GI– versions
architectural possibilities and increases
Standard Variants
the field of vision upwards.
Frame
Features Nordic pine with TOPfinishTM White paint PAINTfinishTM
and sash
GI- roof window has a fixed sash.
Ventilation takes place through the
roof window positioned below. Frame
and sash are delivered with the same Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
inner and outer profiles as the roof
windows with which the window is
combined.
A R C H I T E C T 3.06.04
012005 © 2005 VELUX Group
Technical data GI–
Extending the roof window upwards 78 94 114 134
with GI- elements can now shape 57 GIV M50 GIV P50 GIV S50 GIV U50
your thinking in new ways. There are
three standard shapes, GIV, GID and
GIR with the GIA/GIE available as 116
99
specials each available in four sizes, 67 GID
81
GID GID GID
M51 P52 S54 U56
plus the opportunity to specify your
own shape if required. For further
information please contact VELUX.
57 GIA/ GIA/ GIA/ GIA/
GIE GIE GIE GIE
57
GIR M50 GIR P50 GIR S50 GIR U50
A R C H I T E C T 3.06.05
012005 © 2005 VELUX Group
Conservation Roof
Window System
Centre-pivot window
Application
The VELUX Conservation Roof Window
System offers all the superior technical
features of a VELUX roof window but
in a traditional conservation style.
It allows you to make the area under
the roof truly habitable – not previously
possible with a rooflight. The system
blends in perfectly in sensitive GGL versions
conservation areas with its:
– mullion (Central glazing bar) Standard Standard Variants
– recessed installation
– external black metal work. Frame
Nordic pine with TOPfinishTM White paint, PAINTfinishTM
and sash
Features
Consisting of a GGL centre-pivot roof
window with vertical glazing bar and Exterior Titanium zinc, pre-patinated zinc,
associated flashing. Three different Black aluminium
cladding copper or other cladding colours
versions are available depending on
the roofing material:
• for slate up to a maximum thickness
of 8mm with roof pitches of 35°-90°. Panes PROTEC-STARTM (--73) See section 8
• for profiled roofing material up to a
maximum of 120mm in profile with
roof pitches of 15° - 90°.
Conservation Roof Window System can be combined with:
• for plain tiles up to 15mm thick with
roof pitches of 25° - 90°. Flashings for Exterior sunscreening
An emergency escape/access • Single installation • Awning blind (MHL only)
system is also available which • Twin installation – • Roller shutter
tile only
includes a GPL top-hung window with • Combi installation
vertical glazing bar and associated slate/tile only
flashing. Again choose from the
variants listed above depending on Linings for Controls
roofing material and roof pitch for • Roof • Rod
GPL. • Vertical walls • Electrical
Operation
See section 3.01.00 for GGL and
section 3.02.02 for GPL. Interior sunscreening Additional accessories
• Siesta blinds • Insect screen
• Roller blinds
• Pleated blinds
• Venetian blinds
A R C H I T E C T 3.07.00
012005 © 2005 VELUX Group
Technical data Conservation
Roof Window System
27.5 k Size H f l
f I H W
C04 978 730 919
Height
29
A R C H I T E C T 3.07.01
012005 © 2005 VELUX Group
GVA
Rooflight
Application
GVA rooflight can be installed in all
roof pitches between 20° and 60° in
flat or profiled roofing material up to
60mm in profile.
The traditional style of GVA roof-
light with horizontal top edge and GVA
vertical glazing bar makes it ideal for
historic buildings or for replacing old
cast-iron rooflights.
Frame Black polyurethane
Features
The flashing is an integral part of the
rooflight, which facilitates installation.
GVA has an interior and exterior Sash Black anodised aluminium
A R C H I T E C T 3.08.00
012005 © 2005 VELUX Group
Technical data GVA
GVA
Pane
61
variant
cm 46
Effective daylight area [m2] --59 0.22
VELUX GB/IRL product programme
408
418
424
696
852
550
565
559
190
A R C H I T E C T 3.08.01
012005 © 2005 VELUX Group
GVT Emergency escape/
access rooflight
Side-hung emergency
escape/access rooflight
Application
The side-hung GVT rooflight can be
installed in all roof pitches between
20° and 65° in flat or profiled roofing
materials up to 60mm in profile.
The sash can be opened to 90°
and secured when used for emergency
escape/access. GVT
Features
The flashing is an integral part of the
window, which facilitates installation. Frame Black polyurethane
A R C H I T E C T 3.08.02
012005 © 2005 VELUX Group
Technical data GVT
Pane
154 variant
56
VELUX GB/IRL product programme Effective daylight area [m2] --59 0.45
500
558
794
1220
900
978
*
190
A R C H I T E C T 3.08.03
012005 © 2005 VELUX Group
VLT Rooflight
Application
VLT rooflight is for uninhabited attics
where light and/or ventilation is
required. The window can be used
for both new buildings and for
renovation.
VLT rooflight can be installed in all
roof pitches between 15° and 60° in
flat or profiled roofing material up to
60mm in profile. The window is not
suitable for habitable rooms. VLT – FOR UNINHABITED ATTICS
In the case of a loft conversion
VELUX roof windows are Standard
recommended.
Frame Black polyurethane
Features
The flashing is an integral part of the
window frame, which facilitates
installation. The frame is made of
Sash Black anodised aluminium, top-hung
black polyurethane and the sash of
black anodised aluminium.
Operation
VLT is a top-hung rooflight that opens Pane Standard pane (--00)
outwards.
The window is opened by means
of the handle placed in the bottom
VLT flashings
sash. The sash can be located in
three positions. • Integral part of the frame
• For flat or profiled
roofing material up to
60mm in profile
• Pleated apron
• Single installation only
A R C H I T E C T 3.08.04
012005 © 2005 VELUX Group
Technical data VLT
VLT Pane
61
variant
408
424
460
696
608
550
610
852
565
190
A R C H I T E C T 3.08.05
012005 © 2005 VELUX Group
Electric Skylight System
Application
To bring daylight to inner rooms or
additional daylight to areas not
generally associated with roof
windows because of high level
installation and operation.
Electric Skylight System versions
Features
Based on the GGL/GGU centre-pivot Standard Variants
roof window the Electric Skylight Pine with TOPfinishTM or
Frame
System is provided with all main EVERfinishTM white varnished White paint, PAINTfinishTM
and sash polyurethane with wooden core
electrical components and motor
pre-fitted. It is installed in the same
manner as a standard roof window
and only needs the infra-red receiver Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
unit to be fitted and connection to a
mains supply to be ready for
operation. The system comprises of
the GGL INTEGRA roof window, with
appropriate flashing. The optional Panes PROTEC-STARTM (--73) See section 8
A R C H I T E C T 3.09.00
012005 © 2005 VELUX Group
Technical data Electric Skylight System
Other sizes/combination of
Light transmittance, τ v --73 0.75 EN 410
GGL/GGU are available
Total solar energy
--73 0.54 EN 410
transmittance, g
EASE OF INSTALLATION
• Fit window and flashings like any VELUX window
• Attach rain sensor and infra red receiver
• Connect single power cable to a power point or fused outlet
A R C H I T E C T 3.09.01
012005 © 2005 VELUX Group
Flat Roof Window System
Application
Allows for the installation of a GGL
roof window on to a flat roof
between the pitches of 0-15 degrees.
Features
The Flat Roof Window System
comprises of a GGL roof window
and ECX insulated kerb. The GGL
centre-pivot window is supplied with
the PROTEC-STARTM pane whilst the
ECX kerb is manufactured from
plywood with polystyrene insulation. Flat Roof Window System
Other types of VELUX roof
Standard Variants
windows can also be used.
Frame
Operation Pine with TOPfinishTM White paint, PAINTfinishTM
and sash
Manual and electrical versions are
available.
Flat Roof Window System can be Exterior Titanium zinc, pre-patinated zinc,
Grey aluminium
cladding copper or other cladding colours
combined with:
Interior sunscreening
• Siesta blinds†
• Roller blinds† Panes PROTEC-STARTM (--73) See section 8
• Pleated blinds†
• Venetian blinds†
Exterior sunscreening
• Awning blinds†
• Electrical roller shutter.
†Manual or electric possible.
A R C H I T E C T 3.09.02
012005 © 2005 VELUX Group
Technical data Flat Roof Window System
Size
Pane
98
98
118
measurements
105 mm 55 mm
X
200 mm
H W
71.5° 71.5°
A R C H I T E C T 3.09.03
012005 © 2005 VELUX Group
Smoke
Ventilation System
Application
For providing automatic smoke
ventilation within stairwells or
lobbies. VELUX Service can provide
installation, commissioning and
annual servicing of the system
(see section 2.08.00). Smoke Ventilation System versions
A R C H I T E C T 3.09.04
012005 © 2005 VELUX Group
Technical data Smoke Ventilation System
M08 S06
A R C H I T E C T 3.09.05
012005 © 2005 VELUX Group
Product overview
VELUX roof windows
116
99
GID GID
82
GID
68
351 452 654 856
M51 P52 S54 U56
GGU: Centre-pivot roof window, GIR GIR GIR GIR
Code for interior surface
570
57
61
46
PAINTfinishTM.
624
62
101 601
C01 S01
GGL GFL
GGU
54
TOPfinishTM.
GPU: Top-hung roof window,
778
78
102
C02 GVT VLT
GHL GFL
98
6 1 7 46
104 204 304 404 804 54
C04 F04 M04 P04 U04
GGL GPU GGL GPL GGL GGL GPL
98
GPU
(5) 14 4
11
312
M12 (308)
M08
GIL GIL GIL GIL VEA
VEB
VEC: Roof Terrace, bottom element/ GIU GIU GIU
Pane code
920
VEC
109
92
element. M36
VFA VFA
P36
VFA
S36
A R C H I T E C T 3.10.00
012005 © 2005 VELUX Group