0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
28 tayangan1 halaman
Siemens LCP3000EZ panels are designed to meet virtually any lighting control application. Each panel is equipped with an RS232 interface for easy configuration of inputs and outputs. There is no central or master controller; Each device holds its own operating program in non-volatile memory.
Siemens LCP3000EZ panels are designed to meet virtually any lighting control application. Each panel is equipped with an RS232 interface for easy configuration of inputs and outputs. There is no central or master controller; Each device holds its own operating program in non-volatile memory.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PDF, TXT atau baca online dari Scribd
Siemens LCP3000EZ panels are designed to meet virtually any lighting control application. Each panel is equipped with an RS232 interface for easy configuration of inputs and outputs. There is no central or master controller; Each device holds its own operating program in non-volatile memory.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PDF, TXT atau baca online dari Scribd
virtually any lighting control application. Each panel is equipped with an RS232 LIGHTING CONTROLS
interface for easy configuration of inputs
and outputs. Any panel in the network can be configured from any other panel in the same network. Other options include Ethernet interface, PC software, two different time clocks (4 and 16 control points, which provide the ability to set 324 or 500 schedules respectively), motion sensors, dual sensors for light and temperature and more. These options enable you to have System Features a lighting control system that can meet any relay from a PC. Password protection The Siemens LCP3000EZ is fully even the most demanding applications. allows partial control to individual users. assembled and delivered with all For example, the employee can turn ON specified relays, digital inputs, power Each individual device holds its own or OFF the office lights from any PC. supply and RS232 interface installed in operating program in non-volatile the enclosure. Wall mount the enclosure. memory. There is no central or master Enclosure Connect the 120V AC power supply. controller. This feature prevents entire The LCP3000EZ is enclosed in a NEMA connect the loads to the relays. Connect system shut down, which could happen 1, UL listed enclosure with hinged door the inputs. Then with a PDA with serial on systems with a central logic board. and hinged dead fronts. There are two port support (RS232) (running Palm OS dead fronts, one for the low voltage 3.5 or higher), configure which inputs Networking (24V) section and one for the line control which output/s (relay/s) and the Up to 10 panels can be networked voltage load relays. There is a barrier system is ready to go. The configuration together without the need for any between the two sections. software also can be run on a PC using additional cards or devices. With Palm Emulator software. The optional Web access devices and Technical Literature configuration software and the Palm ComBridge Studio Software, the user You are able to review and download a Emulator are provided with every order can network up to 500 panels. The copy of the LCP3000EZ Lighting Control at no charge. LCP3000EZ interfaces with any Building Selection and Application Guide at Automation System using OPC. http://www.sea.siemens.com/power/pr If your system has more than one panel, oduct/pdprodlc_3000ez.html. A printed simply interconnect the panels with an Web Access Software version of the Selection and Application 18 AWG solid copper twisted pair. Guide, No. LCSA-03000-0604, or the The optional Web access software allows the user access any device in the Technical Data Sheet, No. LCSS-01002- The Siemens LCP3000EZ lighting 0304, can be requested through the control system comes with an LCP3000EZ system. This allows control of Siemens Call Center at 1-800-427-2256. System Specifications ▪ NEMA 1, surface mount, - Are rated 20 Amp, 277 Volt (480V - Time of day (TOD) schedules optional key lock and flush mount kit “Y” with ground three phase loads) - Warn Off - 5 minutes ▪ Enclosures are always 20" wide and ▪ All panel size accept a maximum of ▪ RS-232 interface in every panel 32 digital (switch) inputs: Network up to 10 panels twisted pair 53⁄4" deep; height depends on ▪ number of outputs: - Rated 24V AC/DC wire, without additional cards - 24" high for up to 16 outputs - Can be configured to accept Network up to 500 panels with ▪ - 32" high for up to 32 outputs maintained, or momentary inputs optional Web access devices and - 40" high for up to 48 output relays - Four inputs per module ComBridge Studio Software ▪ Load relays: ▪ 4 control channels time clock allows Ambient Conditions: 324 schedules ▪ - Mechanically held - Ambient operating temperature: - Visual position indicator ▪ 16 control channels time clock allows 23˚F - 113˚F (-5... +45˚C) - Have manual override 500 schedules. Four channels have astronomical clock feature - Ambient temperature (non-op): - Built in timer which can be set in -13˚F - 158˚F (-25... +70˚C) - Both time clocks have 10 years 30 minute intervals up to 6 hours - Relative Humidity battery back up - Eight relays per module (non-condensing): 5% to 93% - Automatic day light savings time - Can be programmed as groups to adjustment control two or three pole loads
11-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog