DETAILS OF BEAMS AT SLAB LEVEL-

Ld OR 0.25 x L1 Ld OR 0.25 x L1 Ld OR 0.25 x L2


(WHICH EVER IS MORE) (WHICH EVER IS MORE) (WHICH EVER IS MORE)
SLAB LVL.

SLAB
Ast1 (Thro.) Ast2(Extra) Ast2(Extra) Ast1 (Thro.) Ast1 (Thro.)

Ld+10Ø
Ld+10Ø
D Stirrups

Asb2(Extra) Asb2(Extra) Asb1 (Thro.)


Asb1 (Thro.)

0.1xL1 0.15xL1 0.15xL2

STPS. IN END ZONE STPS. IN MIDDLE ZONE STPS. IN END ZONE STPS. IN END ZONE
END COL. 2D MIDDLE ZONE 2D 2D
L1 INTERMEDIATE
L2 COLUMN

TYP.REINF. DETAILS IN THE BEAMS SPANNING BETWEEN SUPPORT TO SUPPORT


FOR DETAILS REFER TABLE [3] BELOW
NOTE : AT THE JUNCTION OF TWO DIFF. NUMBER OF BEAMS THE HEIGHER REINFORCEMENT AT THE SUPPORT SHALL BE ADDOPTED.
TABLE -3 DETAILS OF BEAMS AT SLAB LVL-

LONGITUDINAL REINFORCEMENT STIRRUPS


BEAM NO.

BEAM SIDE FACE


SR. NO.

SIZE TOP FACE REINFORCEMENT BOTTOM FACE REINFORCEMENT END MIDDLE REINF.
(ON EACH FACE)
W D Ast1 Ast2 Asb1 Asb2 ZONE ZONE
mm mm (Thro.at Top) (Extra at support) (Thro.at Bottom) (Extra at middle) '2L'STPS '2L'STPS
1 B1 230 450 2#16 - 2#16 - #8@100 #8@150 -
2 B2 230 450 3#16 2#16 3#16 2#16 #8@100 #8@150 -
3 B3 230 450 3#16 - 3#16 - #8@100 #8@150 -
4 B4 230 450 2#16 1#12 2#16 1#12 #8@100 #8@150 -
5 B5 230 450 2#12 - 2#12 - #8@100 #8@150 -

TYPICAL DETAIL OF LINTELS AND LINTEL BANDS


TOP BARS OF LINTEL 2#10
450 REFERENCES: IS 456 - 2016, IS 13920 - 2016, IS 1893 PART (1) : 2016, IS 4326,SP-16,SP-34
2#10 450 2#10
a ARCH. DRG. NO. - ALL ARCH. DRGS

150
#8@200 REVISION

2#10 S.N. DATE DESCRIPTIONS INITIAL

a 2#10 BARS OF R.C.C. BAND b PROJECT


BOTTOM BARS OF LINTEL
2#10 PROPOSED VIVECHANA ROOM FOR 4 NOS. S.I.
BRICK WALL CLEAR OPENING
BRICK WALL DETAIL OF R.C.C. BAND AT IN THANA COMPLEX, ELIYA, DISTT. - CHANDAULI, U.P.

DETAIL OF CONNECTION IN R.C.C. LINTEL & LINTEL BAND LINTEL LVL. AT SEC. a - a DRG. TITLE:

DETAIL OF BEAMS & LINTEL DETAILS


(b = WALL THICKNESS)
(FOR LINTEL REFER TABLE -3)
DATE JAN - 2020 CONSTRUCTION AGENCY : SHEET
NO.
TABLE-3 DETAIL OF LINTELS FOR DOOR / WINDOW LINTELS: DRN.
CKD. Er.S.B.Chaudhary U. P. P. W. D.
TCD.
SCALE N.T.S. DRG. NO.
ST-03
FOR 230 TH WALL FOR 115 TH WALL ARCHITECT:

Lintel Cross Longitudinal Reinforcememnt VASTUVID VARG


Lintel Cross Longitudinal Reinforcement
S. No.

DOOR/ Stirrups DOOR/ Stirrups KARYALAYA PRAMUKH ABHIYANTA


WINDOW Section WINDOW Section LOK NIRMAN VIBHAG , U.P. LUCKNOW
BOTTOM BARS TOP BARS '2L' STPS BOTTOM BARS TOP BARS '2L' STPS
OPENING (L) ( B X D ) OPENING (L) ( B X D )
1 >750<1000 230 X150 2 # 12 2 # 10 #8@200 >750<1000 115 X150 2 # 10 2 # 10 #8@200 Structural Consultants:

2 >1000<1500 230 X175 2 # 10 +2#12 2 # 10 #8@175 >1000<1500 115 X175 2 # 12 SILHOUETTE ILLUSION
2 # 10 #8@175
ARCHITECTS & ENGINEERS
3 >1500<2000 230 X200 2 # 12 +2#12 2 # 10 #8@150 >1500<2000 115 X200 2 # 12 2 # 10 #8@150 D-217, VIBHUTI KHAND, GOMTI NAGAR
LUCKNOW. Ph.-7752944777,9795499036.