HIDROLIKA
BAB 10
METODE-METODE PERHITUNGAN
C2 y4
x=
g
y− (
4 yc 3
+ Constant)
Where C is Chezy’s resistance factor.
dy So−Sf
=
dx Q2 y
1−
g A3 ( )
For a wide rectangular channel, by considering unit width
T =1 , A= y∧Q=q=Vy , R= y
Also by Chezy formula
V =C √ RSf =C √ ySf
v2 q2
Sf = =
C2 y C 2 y 3
3
−g yc
dy C 2 y ( ) q = yc 2
dx
=
yc (g )
3
3
1−
y ( )
yc 3
( )
dx=
1
−g yc
c2 (
y
3
+
y
g yc
( ) ( )( )
c2 y
3
) dy
−c 2 y 4 c 2 y
x= ( +
4 gy c3 g )
+Cosntant
C2 y4
x=
g
y− (
4 yc 3
+ Constant)
10.2 Show that the condition for the existence of a point of inflecion on the flow profile may be
expressed as
M
yn
Mu N −N ( )
yc
u M + N−M =0
At the point of inflection shows that the equation is equals to 0.
1 2 n yn m
=
2
M u −NM
yc ( )
u M m + NM + c
9 3
= −3 X 9+3 X 0+ c=0
2
= 4,5 – 243 + 0 + c = 0
= C = -238,5
dy −S 0−S
=
dx 1+ αd (V 2 /2 g)/dy
u N −M
u
∫ 1+u N
du
0
L=2.1 [ 0.476−(−0.877 ) +0.197 ×(−1.08) ]
10.5 Show that the flow profile in a frictionless rectangular channel expressed as:
Answer:
dh Se
=
dx hc
3
1− ( )
h
y 3 x
hc
∫
yc
[ ( )]
1−
h
dh=Se ∫ dx
0
yc 3 3
y+ − yc=2 Sex+ c 1
2 y2 2
y
x= ¿
2 Se
10-6 Selesaikanlah contoh 10-1 dengan menganggap α = 1,0 lalu selidikilah pengaruh nilai α
terhadap bentuk profil aliran.
Penyelesaian:
α v2 y4
X= (y - 3 ) + konstanta
g yc
2α v 4 y3
X= (y - )
g 3 y2
Subsitusikan α = 1,0 ; g = 10
2x 1x v 4 y3
X= (y - )
10 3 y2
v 4
X= ( )
5 3
4
X= v
15
10-7 Hitung profil aliran dalam saluran seperti diuraikan dalam contoh 10-1 bila So = 0.0169.
Anggaplah bahwa profil dimulai pada lokasi bending pada kedalaman 5 kaki dan berakhir di hulu
pada kedalaman kritis. Pakailah :
Penyelesain :
QA 2
dy S 0−
dx
= C ( ).R
1−a ( QA )2 . D /g
A=Bxh
= 1.524 m x 0.45 m
= 0.6858 m 2
P = B + 2h
=1.524 + 2 (0.45)
= 2.424 m
A
R=
P
0.6858
=
2.424
= 0.2829 m
2 1
1
V = ( R) 3 (S )2
n
2 1
1
= ( 0.2829) 3 (0.0169) 2
0.01
= 5.6022 m/s
Q=AxV
= 0.6858 x 5.6022
= 3.84 m3 /s
10-8
2 1 2 1
1 1
Q = An Rn 3 S 2 =B hn R n 3 S 2
n n
2 1
1 1
Q = h n Rn 3 S 2 2,5 = h n 5 ¿
n 3 0,015
5
h n3 =1,186 h n=1,1076 m
Kedalaman Kritik:
√ √ q2 2
3 3 2,5
h c= =¿ ¿= 0,8605m
g 9,81
10-9. Bila kemiringan suatu saluran memiliki ciri-ciri penampang seperti di ujung hilir saluran seperti
diuraikan dalam contoh 10-1 dengan suatu perubahan berangsur dari 0,0016 di bagian hulu menjadi
0,0169 di bagian hilir, hitung profil aliran di bagian hilir dari titik perubahan ke suatu penampang
yang kedalamannya 1% lebih besar dari kedalaman normal.
Pakailah :
1. Metode integrasi-grafis
2. Metode integrasi-langsung
3. Metode tahapan langsung
4. Metode tahapan standar
Penyelesaian :
QA 2
dy
dx
=
S 0−
C ( ).R
1−a ( QA )2 . D /g
Q : debit mula-mula
yn 3
1−( )
dy y
=S 0
dx y 3
1−( c )
y
A
A=Bxh R=
P
0.225
= 0.5 m x 0.45 m =
1.4
= 0.225 m 2 = 0.16 m
P = B + 2h
= 0.5 + 2 (0.45)
= 1.4 m
2 1
1
V = ( R) 3 (S )2
n
2 1
1
= ( 0.16)3 (0.015) 2
0.01
= 3.6 m/det
W =√ 0.5 h
¿ √ 0.5 x 0.45
= 0.4 m
Q hitung = A x V
= 0.225 x 3.6
= 0.81 m3/det
Q hitung = Q rencana
Q 2 13
y c =[
( )
B
]
g
25 2 13
y c =[
( )
12
]
9,81
4,34 13
y c =[ ]
9,81
y c =0,762 m
10.10 Bila kemiringan suatu saluran memiliki ciri-ciri penampang seperti diuraikan dalam contoh 10-
1 dengan suatu perubahan berangsur dari 0.0169 di bagian hulu menjadi. 0.0016 di bagian hilir,
hitung profil aliran pada bagian hilir dari titik belok sampai penampang kritis. Aliran di saluran hulu
dianggap seragam. Gunakanlah:
dy So−Sf
=
dx 2
Q y
1− ( )
g A3
T =1 , A= y∧Q=q=Vy , R= y
V =C √ RSf =C √ ySf
v2 q2
Sf = =
C2 y C 2 y 3
3
−g yc
dy C 2 y ( ) q = yc
2
dx
=
yc (g )
3
3
1−
y ( )
yc 3
( )
dx=
1
−g yc
c2 (
y
3
+
y
g yc
( ) ( )( )
c2 y
3
) dy
−c 2 y 4 c 2 y
x= ( +
4 gy c3 g )
+Cosntant
C2 y4
x=
g
y− (
4 yc 3 )
+ Constant
0.01692 0.00164
x=
9.807 (
0.0016−
4 x 0.0016 x 0.001693 )
+Constant
x=−6,131818087 x 10−6
10.11 Water flows from under a sluice into a trapezoidal channel having b = 20 ft, z =2, S 0 =
0.0016, α = 1.10, and n= 0.025. The sluice gate is regulated to discharge 400 cfs with a depth
equal to 0.55 It at the vena contracta. Compute the flow profile. If a hydraulic jump occurs at
the downstream end, starting with a depth of 1.6 ft, determine the distance from the vena
contracta to the foot of the Jump.
Answer
Giv.
yn = 2.67 ft
yc = 2.22 ft.
Considering an average depth of 1.61 ft
The hydrauhc exponents are N = 3.43 and M = 3.17. Thus, J = 2.72, N/J = 1.26, and
(yc/yn) MJ/N = 0,442.
Q = 400
Kn= Q / √ S 0 Zc = Q / √ g
y T A R R2/3 K z dx/dy ΔA x
54.256 1.28570 1.18239 3823.50 74.3674 20.2577 12.4625 12.4625
2.22 28.88
8 6 1 4 1 6 3 3
51.959 1.25505 1.16352 3603.15 70.0833 21.0507 12.6265 13.6265
2.14 28.56
2 3 2 9 1 5 9 9
44.393 1.14712 1.09582 2899.40 56.4254 23.0904 12.9298 14.9298
1.87 27.48
8 7 4 9 6 9 7 7
1.03111 1.02063 2258.00 44.0159 24.3721 12.9481 15.9481
1.6 26.4 37.12
1 5 3 4 2 7 7
30.137 0.90503 0.93564 1680.61 32.8802 25.0679
1.33 25.32 12.7602 16.7602
8 9 6 9 8 7
23.689 0.77165 0.84129 1187.83 25.2416 12.4117 17.4117
1.07 24.28 23.4001
8 5 6 6 5 4 4
0.61714 0.72486 746.529 14.9132 24.8479 11.8526 17.8526
0.8 23.2 17.28
3 5 8 3 8 9 9
11.161 0.44117 385.528 7.92882 23.5843 10.9697 17.9697
0.53 22.12 0.57953
8 8 3 4 4 5 5
0.24430 0.39080 129.172 2.84453 20.6139 9.40429
0.27 21.08 5.5458 17.4043
8 4 3 3 8 7
0 20 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0!
y u v F(u,N) F(v,J) x L
0.83146 0.79250 2.13198 0.46877 49.4558 36.9933
2.22
1 2 8 1 4 2
0.80149 0.75668 1.88023 0.53155 31.1285
2.14 44.7551
8 9 2 9 1
0.70037 0.63843 1.41797 0.70493 35.3549 20.4250
1.87
5 4 7 6 4 7
0.59925 1.20869 30.1759 14.2277
1.6 0.52455 0.82709
1 7 3 6
0.49812 0.41557 1.10083 0.90822 26.6890 9.92881
1.33
7 4 2 5 1 2
0.40074 0.31595 1.04540 0.95645 24.1394 6.72772
1.07
9 1 9 2 7 6
0.29962 0.21902 1.01628 0.98392 21.9660 4.11340
0.8
5 3 1 6 9 7
0.19850 0.13037 1.00391 20.0723
0.53 0.99608 2.10262
2 2 8 7
0.10112 0.05573 1.00038 0.99961 18.3884 0.98416
0.27
4 3 6 1 6 4
0 0 0 1 1 1 #DIV/0!
0
0.27
2.14 7.698348 51.9592 1.8193 3.651706 0.926009 3.066009 0.003234 0.004569 0.004127 0.012773 0.25316 -7.31372
0
2
0.05560
1.87 9.010267 44.3938 1.615495 2.270393 1.268514 3.138514 -0.07251 0.010067 0.007318 0.009582 -7.56688 398.3669
0
0.1
1.6 10.77586 37.12 1.406061 1.302851 1.814363 3.414363 -0.27585 0.025092 0.01758 -0.00068 405.9338 426.3594
0
0.055
1.33 13.27237 30.1378 1.190276 0.669068 2.752434 4.082434 -0.66807 0.074123 0.049608 -0.03271 20.42558 29.8513
0
6
2.31705
1.07 16.8849 23.6898 0.975692 0.302085 4.454687 5.524687 -1.44225 0.265702 0.169913 -0.15301 9.425721 13.71121
0
6
2.31705
0.8 23.14815 17.28 0.744828 0.102589 8.372449 9.172449 -3.64776 1.470475 0.868089 -0.85119 4.285492 5.543165
0.53 35.83651 11.1618 0.504602 0.021611 20.0665 20.5965 -11.424 16.73029 9.10038 -9.08348 1.257673 1.388219
0.27 72.12665 5.5458 0.263083 0.001597 81.28522 81.55522 -60.9587 917.203 466.9667 -466.95 0.130547 0.130547
station y A V V2/2g R R4/3 Sf BetweenSf Delta x hf
73+13 2.14 51.9592 7.698348 0.926009 1.8193 3.651706 0.004569 0.004127 0.25316 0.001045
d. The standard step method
39+83 1.87 44.3938 9.010267 1.268514 1.615495 2.270393 0.010067 0.007318 -7.56688 -0.05537
42+63 1.6 37.12 10.77586 1.814363 1.406061 1.302851 0.025092 0.01758 405.9338 7.136129
29+85 1.33 30.1378 13.27237 2.752434 1.190276 0.669068 0.074123 0.049608 20.42558 1.013264
13+71 1.07 23.6898 16.8849 4.454687 0.975692 0.302085 0.265702 0.169913 9.425721 1.601548
55+43 0.8 17.28 23.14815 8.372449 0.744828 0.102589 1.470475 0.868089 4.285492 3.720187
13+88 0.53 11.1618 35.83651 20.0665 0.504602 0.021611 16.73029 9.10038 1.257673 11.4453
466.9666 60.96109
1+30 0.27 5.5458 72.12665 81.28522 0.263083 0.001597 917.203 0.130547
632 698
10-13 Air mengalir dari suatu penguras ke dalam saluran trapezium dengan b=20 kaki, z=2,S 0= 0,
α=1.10 dan n=0.025. pintu penguras diatur untuk debit 400 kaki kubik per detik dengan kedalaman
0.55 kaki di kontraksi aliran. Hitung profil alirannya. Bila terjadi loncatan hidrolik di ujung hilir,
dimulai pada kedalaman 1.6 kaki, tentukan jarak dari kontraksi aliran ke kaki lonatan air.
y u v F(u,N) F(v,J) x L
0.83146 0.79235
2.22 1 2 0.979 0.962 0 0
0.80149 0.75651
2.14 8 6 0.917 0.888 0 0
0.70037
1.87 5 0.6382 0.756 0.699 0 0
0.59925 0.52427
1.6 1 4 0.627 0.552 0 0
0.49812 0.41527
1.33 7 6 0.511 0.431 0 0
0.40074 0.31565
1.07 9 3 0.404 0.319 0 0
0.29962 0.21875
0.8 5 1 0.301 0.219 0 0
0.19850 0.13015
0.53 2 5 0.2 0.132 0 0
0.10112 0.05560
0.27 4 2 0.1 0.055 0 0
0 0 0 0 0 0 0
Metode Tahapan Langsung
Metode Tahapan Standar
10-15. If the channel described in Prob. 10-8 is horizontal, compute the flow profile from the control
section to an upstream section where the depth of flow is 10 ft. Use:
S0 = -0,0016
Tabel S0 – Sf rata-rata
S0 – Sf rata-rata
-0,000166376664
-0,000167779729
-0,000169380234
-0,000161142413
-0,000161389241
-0,000161715729
-0,000160839483
-0,000161947394
-0,000160446734
-0,000159234103
-0,000160375938
-0,000159374532
-0,000159222238
-0,000159839432
-0,000159849375
-0,000158437294
-0,000158237383
-0,000158478493
Penyelesaian.
Dari data, yc = 4,35 kaki dan yn = 2,60 kaki. Karena ye > yn, kemiringan saluran bersifat
terjal. Dari Gambar 10-7 penampang kontrol terletak di tempat pemasukan; air masuk ke
gorong-gorong dengan kedalaman kritis berarti tinggi aliran kurang dari yo, namun lebih
besar dari yn. Profil aliran adalan jenis S2.
Tabel 10-5 memperlihatkan perhitungan profil aliran yang cukup jelas. Profil hasil hitungan
digambarkan pada Gambar 10-7. Juga digambarkan garis energi yang menunjukkan variasi
energi sepanjang gorong-gorong. Pethitungan dibuat melebihi panjang gorong-gorong agar
tinggi air di tempat pengeluaran dapat dihitung. Tinggi ini terbukti 2,81 kaki dan kecepatan di
tempat pengeluaran 19,4 kaki per detik. Perlu dicatat bahwa bila aliran terisi penuh di tempat
pengeluaran, kecepatannya hanya mencapai 10 kaki per detik.
Jika α = 1,1
α V2 / 2g
0,6314
0,65615
0,6633
0,78265
0,87175
0,98175
1,0318
1,0615
1,09175
10.17
d = 72 in = 6 ft
L = 250 ft
So = 0.02
Q = 252 cfs
n = 0.012
a=1
yc = 4.35 ft
yn = 2.6 ft
y 1=2.6+ ( 2.6 ) ( 0.01 )=2.626 ft
y 2=( 0.02 ) ( 250 )=5 ft
2.626+5
y avg = =3.812 ft
2
y 3.812
= =0.6353
b 6
Fig 4-2, M = 3.9
Fig 6-2, N = 2.9
J = 2.7/(2.7 – 3.9 + 1) = -9
Berdasarkan lampiran tabel D,
y u=y/yn v=u^(N/J) F(u,N) F(v,J)
5 1.923 0.81 0.183 0.823
2.626 1.01 0.9968 1.572 1.41
dif 0.913 -1.389 -0.587
A = 2.6/0.02 = 130
B = (4.35/2.6)3.9(-9/2.9) = -23.097
L = 130[0.913 – (-1.389) + -23.097 x -0.587 = 2061.79 ft
10.18
Suatu pelimpah trapesium prismatis terbuat dari tanah dengan kemirian tebing 3:1
mengalirkan debit 1500 kaki kubik per detik. Dasar pelimpah mendatar, sepanjang 200
kaki dan lebar 75 kaki dibagian saluran diantara penampang kontrol kritis di hilir dan
reservoar di hulu. Nilai n manning dianggap 0.035. Dengan suatu cara seperti diuraikan
dalam bab ini, tentukan
a. Profil aliran diantara reservoar dan penampang kontrol
b. Kehilangan energi akibat gesekan melalui pelimpah dihitung dalam kaki
c. Tinggi taraf air reservoir
b = 200 ft
L = 75 ft
Q = 1500 ft3/s
n = 0.035
z=3
S0= 0
Pelimpah Trapesium dengan kemiringan tebing 3 : 1
a. Profil Aliran
15002 (200+2 x 3 x y c )
yc=
√
3
9.81(3+3 x y c )3
=60.253 ft
1 (200+3 y n ) y n 32 1
1500= ( 200+3 y n ) y n x
(
0.035 200+2 x y n √ 1+3 2
+ S0 2
)
y n=63.825 ft
A = y (200+3 y )
y ( 200+3 y )
R=
200+3 y √ 5
y T A R 2
K Z dx ∇A x
R3 dy
1.5 12 306.75 1.46 1.29 872.42 15.4 143001.4
1.4 11.6 285.88 1.365 1.23 755.47 12.9 16705.98 8123.329 815.155
1.3 11.2 265 1.27 1.17 647.21 12.1 7166.18 1254.748 9621.42
1.2 10.8 244.32 1.174 1.11 565.2 10.74 3892.37 584.78 9841.11
LV2 75 x 302
h L =f h L =0.731 =2514.91 ft
D2 g 1 x 2(9.81)
10.19
Suatu pelimpah trapesium primatis terbuat dari tanah dengan kemiringan 3:1 dan lebar dasar 75
kaki mengalirkan debit 1.500 kaki kubik per detik. Pelimpah memiliki dasar yang mendatar di hulu
suatu penampang kontrol kritis sepanjang 90 kaki, dan kemiringan menanjak 10:1 untuk jarak ke
hulu 100 kaki dari reservoir. Nilai n Manning adalah 0.035 dengan salah satu cara seperti yang
diuraikan dalam bab ini tentukan :
jawab
A.
So = 0.0016
α = 1.10
Yc = 2.22 kaki
Yn = 3.36 kaki
n = 0.035
S0 -
y A R R^(4/3) V V^2/2g E ∆E Sf Śf S0− Ś f ∆X x
9
0 18000 42.60433 148.8007 0.083333 0.000347 90.00035 2.57523E-08
8
5 16150 40.36173 138.45 0.092879 0.000431 85.00043 4.999916 3.43817E-08 3.0067E-08 0.0016 3125.006 3125.006
8
0 14400 38.11834 128.2858 0.104167 0.000543 80.00054 4.999889 4.66726E-08 4.0527E-08 0.0016 3125.01 6250.016
7
5 12750 35.87404 118.3152 0.117647 0.000692 75.00069 4.99985 6.45513E-08 5.5612E-08 0.0016 3125.015 9375.031
B.
Garis Energi
0
0
0.5 1 1.5 2 2.5 3 3.5 4 4.5
10.20
Solve the problem in Example 10-10 by the standard step method , for a design of 500.000 cfs.