Directional Controls
Pilot Operated
Directional Control Valves
DG5S4-10**-53 DG4S4-01-50 Air Gap Pilot Valve
DG5S4-10**-80 DG4S4-01-60 Wet Armature Pilot Valve
DG5S4 -10** -90 DG4V-3S-60 Pilot Valve
DG5S4 -10** -100 DG4V-3-60 Pilot Valve, High Performance
NFPA D10, ISO-4401-10
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features and Benefits
Functional Symbols
Minimum Pilot Pressure
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Basic Characteristics
Mounting Interface
Shifting Action
Mounting Position
Installation Data
Optional Features
Service Information
Flow Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Subplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2
Introduction
DG5S4-10**- 100 uses a DG4V-3-60 Solid cast body and core passages for
high performance D03 pilot valve maximum strength and minimal
207 bar (3000 psi). pressure drop.
Functional Symbols
Double Solenoid - Spring centered, Double Solenoid - No-spring, Double Solenoid - Pressure centered,
all spools 0, 2, 6, 9 spools all spools
a A B b a A B b a A B b
PR PR
P T drain drain P T P T drain
Single Solenoid - Shift to center, Single Solenoid - Spring offset, Single Solenoid - Spring centered,
all spools 0, 2, 6, 9 spools all spools
A B b A B b A B b
On pressure centered models end covers cannot be interchanged. Pilot pressure is not available through use of integral check valves.
3
General Information
DG5S4-10**-** Pilot Operated Directional Valves
Basic Characteristics Pressure centered models: Valve Internal drain may be used with all
spool is returned to center position valves, however, an integral pressure
Max. pressure: 207 bar (3000 psi) by pilot pressure, when solenoids port check valve (see optional check
Max. flow: 946 l/min (250 USgpm) are de-energized. If pilot pressure valve note) is required for valves using
Max. pressure port T (external drain): fails or falls below the required an internal pilot source with an open
. . . . . . . . . . . . . . . 207 bar (3000 psi) minimum, the valve spool will spring center spool (0, 4, 8 and 9 types) in
Max. pressure port T (internal drain): return to center position. (At spring order to maintain pilot pressure. If an
DG5S4-10**-53 – 69 bar (1000 psi) centered valve flow rates.) external pilot source is used then an
DG5S4-10**-80 – 69 bar (1000 psi) integral check is not required. When
DG5S4-10**-90 – 100 bar (1450 psi) Caution internal pilot drain is required, order
DG5S4-10**-100 – 207 bar (3000 psi) according to model code. (Pressure
Surges of oil in a common tank line
Max. pilot pressure: centered valves not included.)
serving these and other valves can
. . . . . . . . . . . . . . . 207 bar (3000 psi)
be of sufficient magnitude to cause
Weights: - See installation drawings. External: When the possibility of
inadvertent shifting of these valves.
Click here for Fluid Cleanliness This is particularly critical in the pressure surges in the tank line exists,
information. no-spring detented type valves. externally drained valves are
Separate tank lines or a vented recommended. For externally drained
Mounting Interface manifold with a continuous models, the pilot valve drain line must
downward path to tank is necessary. be piped directly to tank through a
ISO 4401-10
surge-free line so there will be no back
NFPA D10
pressure at this drain. (Reference
NOTE
Shifting Action connection “Y”.)
Any sliding spool valve, if held for
Spring centered, pressure centered and long periods of time, may stick and Pressure Centered Drain
spring offset models must be energized not spring return due to fluid residue (external only)
continuously to maintain the shifted formation and therefore, should be External pilot drain explanation above
position. Detented no-spring models cycled periodically to prevent this applies to “Y” drain port. Pressure centered
may be energized momentarily from happening. “W” drain connection must be piped
(approximately 0.1 second). directly to tank through a surge free line so
When used as other than a normal
there will be no back pressure at this drain.
Pressure centered and spring centered 4-way valve, consult your Vickers
models return valve spool to center representative. Optional Features
position when solenoids are de-energized.
Mounting Position Pressure Centered Valves
Integral Check Valves
Spring offset models return spool to No-spring detented valves must be
Fast Response
offset position by pilot pressure when installed with the longitudinal axis
Electrical Options
solenoid is de-energized. horizontal for good machine reliability.
The mounting position of spring-offset
When no-spring detented models are models is unrestricted provided that the Service Information
de-energized, the pilot and main spools pilot pressure supply is maintained as
remain in the last position attained, required. (Spring offset valves do not Refer to specific Vickers parts drawing
provided there is no shock, vibration, have a spring in the main spool section.) for service parts information. A complete
unusual pressure transients and the parts breakdown is contained in this
spool axis is horizontal. If pilot pressure Installation Data drawing.
fails or falls below the minimum, the Order by literature number.
Pilot Valve Drain
main spool will spring center (at spring DG5S4-10*(A/B/C/F/N)-*-90/100 . . I-3890-S
Internal: To provide maximum flow
centered flow rates) and cannot drift to DG5S4-10*(A/B/C/N)-*-80 . . . . . . . . I-3883-S
without malfunction, pilot pressure of
reversal of flow (pilot stage remains in DG5S4-10*(A/B/C/N)-*-5* . . . . . . . . I-3624-S
internally drained valves must always
detented position). DG5S4(L)-10*D(X)-*-5* . . . . . . . . . . I-3625-S
exceed tank line back pressure by a
DG5S4-10**-**DC-5* . . . . . . . . . . . . I-3499-S
minimum of 5,2 bar (75 psi) for spool
Caution XDG5S4-10**-5* . . . . . . . . . . . . . . . . I-3501-S
types 0, 4, 8 & 9 and a minimum of 10,3
Because of this, flow conditions of bar (150 psi) for all other spools.
the spring centered position must be
selected with care, both for the effect
on the direction of the flow, and the
pilot pressure. (The “9” main spool
will not ensure sufficient pilot
pressure in the center position.)
4
Model Code
D05 Pilot Operated Directional Valves
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 Special Solenoid Features 8 Spool/Spring Arrangement 14 Pressure Port Check Valve Option
X- Solenoids for hazardous A -Spring offset K- 0,34 bar (5 psi) cracking press.
locations B -Spring centered with solenoid “A” R- 3,4 bar (50 psi) cracking press.
XM - Solenoids for mining applications removed. S- 5,2 bar (75 psi) cracking press.
Blank - Omit if not required. C -Spring centered. Blank - Omit if not required
D -Pressure centered.
Note: “X” or “XM” not available on plug-in type valves
or with solenoid indicator lights. F - Shift to center from spring offset -
single solenoid. 15 Wet Armature Solenoids
N -No-spring detented (pilot valve only) W - Wet armature solenoids &
2 Electrical Plug-in Options non-serviceable core tubes.
PB - Insta-plug (male & female 9 Pilot Pressure
receptacle).
(required for pressure centered ”D” 16 DIN 43650 Std. Electric Plug
PA3 - NFPA 3-pin conduit connector.
models)
PA5 - NFPA 5-pin conduit connector. Blank - Omit if not required.
Use “W” wiring housing in model A -14-69 bar (200-1000 psi)
code with connector. B -69-138 bar (1000-2000 psi)
Blank - Omit if not required. Omit for 138-207 bar (2000-3000 psi) 17 Electrical Service
Wet armature solenoids:
3 Directional Control Valve 10 Fast Response B - 115/120 V - 60 Hz & 110 V - 50 Hz
(omit for standard low shock models) D - 230 V - 60 Hz & 220/230 V - 50 Hz
Subplate mounting; solenoid controlled; F - 6 V DC
Note: Not available with pressure centered “D” and
pilot operated; sliding spool; 4-way flow “DB” models. G - 12 V DC
direction. H - 24 V DC
Air Gap solenoids:
11 Main Stage Spool Control Options Blank for standard 115V-60 Hz.
4 Solenoid Indicator Lights
1- Spool stroke length adjustments. Specify non-standard voltages
(omit if not required) (i.e. 230V-60 Hz, 24V DC, etc.)
2- Pilot choke adjustments
(DGMFN-5-Y-AW-BW-20) spool
5 “W” Wiring Housing Option shift control.
3 - Pilot choke & stroke adjustments.
18 Design Number
6 Valve Size 7 - Stroke adjustment “A” port end only Subject to change.
8 - Stroke adjustment “B” port end only -53 design uses a DG4S4-01-50 Air Gap
1-1/4”valve size NFPA - D10 2-7 - Pilot choke adjustment & stroke pilot.
(ISO-4401-10) mounting interface. adjustment “A” port end only. -80 design uses a DG4S4-01-60 Wet
2-8 - Pilot choke adjustment & stroke Armature pilot.
7 Spool Types adjustment “B” port end only.
5
Pressure Drop
6
Flow Ratings
Pressure Drop Across Total must be greater than minimum determined from pressure drop chart for
bar/psi for good machine reliability. standard valve and adding pressure
Check Valve drop induced by check valve (see
Total pressure drop is determined from To determine check valve cracking graph). Total must be greater than the
the pressure drop induced by check pressure needed to provide pilot minimum for good machine reliability.
valve and other sources. (See graph, pressure, calculate total pressure drop (See pilot pressure and integral check
pilot pressure and integral valve notes.) through valve (P to T) on center at valve notes.)
minimum flow. Total pressure drop is
Flow - USgpm
10 20 30 40 50 60 70 80 90 100 110 120 130 140
11,0 160
9,7 140
Pressure Drop - bar
6,9 100
“S” Model
5,5 80
“R” Model
4,1 60
2,6 40
“K” Model
1,4 20
0 0
38 76 114 151 189 227 265 303 341 379 416 454 492 530
Flow - l/min.
Flow Ratings
Recommended Flow Maximum Flow
Valve Type Spool Type Capacity l/min (USgpm) without Malfunction
l/min (USgpm) @ bar (psi)
No-spring detented 0, 2, 6 & 9
Spring centered & 0, 4 & 8 473 (125) 946 (250) @ 207 (3000)
Shift to center 2, 3, 6, 31 & 33
322 (85) @ 207 (3000)
1, 9 & 11 322 (85) 473 (125) @ 138 (2000)
568 (150) @ 69 (1000)
Spring offset 0, 2, 6 & 9
Pressure centered 1, 0, 2, 3, 4, 6, 8, 9, 11, 473 (125) 946 (250) @ 207 (3000)
31 & 33
As system flow increases the minimum pilot pressure required increases. These spools will operate satisfactorily in excess of
946 l/min (250 USgpm) with higher pilot pressures.
NOTE: For the type 52 spool flow recommendations contact your Vickers representative.
Fast valve switching of large oil volumes, without adequate decompression circuitry, can develop instantaneous flows well
above the maximum ratings. The type 8 spool may spin within the body, causing unusual valve body bore wear when applied in
this type of circuit. With this and other spool types, valve malfunction might occur. Where these applications exist use the DG5S4-10**-S534
special designator for the 4C and 8C anti-spin spools/spring.
7
Installation Dimensions
DG5S4-102C-WB-80
Double Solenoid No Spring Detented
& Spring Centered Models
Millimeters (inches)
Weight @ 45,4 kg (100 lbs.)
Pressure port
77 190,5
(3.03) (7.50) Pilot port Y
76,2
(3.00)
158,8
(6.25)
Tank port 196,9
(7.75)
79,2
(3.12)
Pilot port X
19,1 (.75) R.
114,3
(4.50)
Port A Port B
∅ 19,8 (.781) 6 holes for
mounting. Maximum torque
285 Nm (210 ft.lbs.)
241,3 69,9
(9.50) (2.75)
35,1
(1.38)
Test connections
.4375-20 UNF-2B thd.
201,2
(7.92)
258,3 235
(10.17) (9.25)
252 165,1
(9.92) (6.50)
7,1
(.28)
82,6 65
(2.56) 22,4 35,1
(3.25) 98,6
(.88) (1.38)
288,6 6,4 (3.88)
(9.00) ∅ (.25)
378,0
(14.88)
8
Installation Dimensions
173,8 (6.84) AC
Single Solenoid - Spring 212,4 (8.36) DC
Offset, Single Solenoid 45,3
(1.78)
Spring Centered & Shift to
Center Models
Millimeters (inches)
Weight @ 44 kg (97 lbs.)
263,8
(10.4)
Mounting Surface
DG5S4–10*D
Pressure Centered Pilot
Operated Models
This option provides faster spring
centering time by using pilot pressure to 124
center the spool. The centering springs 263,8
(4.88)
(10.4)
are used in addition to pilot pressure to
insure positive centering of the spool.
The valve spool is returned to center
position by pilot pressure and centering
springs. If pilot pressure fails or falls
below the required minimum, the spool
will return to center position at minimum
pilot pressure flow rates for pressure 446
centered valves. (17.56)
DGMFN-5-Y-A1W-B1W-30
Pilot Choke
Pilot choke is adjusted by backing off
Nut 13,0 (.51)
locknuts and turning adjusting screws across flats
inward (clockwise) to decrease rate of 50,8
M8 x 1.0 thread (2.00)
spool travel and outward
(counterclockwise) to increase the rate. 22,1
Pilot oil for models with this feature (.87)
Pilot choke
should be taken from a source having a 302,8
constant pressure. See spool control (11.92)
Screwdriver slot
modifications in model code.
Stroke Adjustments
Stroke Stroke
Stroke adjustment limits movement of adjustment adjustment
the main stage spool. Backing off the 63,5
jam nut and turning the adjusting screw (2.50)
inward (clockwise) decreases spool
stroke. See spool control modifications 256,7 256,7
in model code. (10.11) (10.11)
9
Electrical Information
Solenoid Energizing
When solenoid “A” is energized, flow is
Click here for information on
always P to A. When solenoid “B” is
DG4V3-60 (M in model code) optional
energized, flow is always P to B. This is pilot.
in accordance with the ANSI-B93.9
standard. Spring offset valves as shown
(not LH) port P to A in the offset
position. Solenoids “A” and “B” are
identified on the diagram plate on the
side of the pilot valve.
Solenoid Energizing
Solenoid Solenoid
Identification Voltage Inrush Amps Holding Amps
Letter Rating (rms) (rms) Holding Watts
B 120V AC 60 Hz 3.80 0.69 35
110V AC 50 Hz 4.10 0.85 33
D 240V AC 60 Hz 2.10 0.34 36
220V AC 50 Hz 2.30 0.45 34
ED 240V AC 50 Hz 1.85 0.27 28
A 110V AC 50 Hz 3.80 0.63 29
C 220V AC 50 Hz 2.00 0.30 28
G 12V DC 3.67 44
H 24V DC 1.83 44
J 48V DC – 0.92 44
X 250V DC 0.17 44
DP 125V DC 0.35 44
Solenoid Current
115V-60 Hz solenoids are standard.
Specify in model number if other than
115V-60 Hz service is desired. See
model code.
Solenoid Current
Approximate Maximum Inrush Amps* Holding Amps Holding Watts
115V AC - 60 Hz 5.1 .61 –
115V AC - 50/60 Hz (50) 3.25 - 60 4.97 (50) .56 - 60 .59 –
230V AC - 60 Hz 2.55 .32 –
460V AC - 60 Hz 1.27 .16 –
6V DC – – 24
12V DC – – 24
24V DC – – 24
10
Electrical Information
NFPA Hydraulic Valve The five pole plug has four leads 101,6 terminals. The #4 and #2 leads are
(4.0) long and one 177,8 (7.0) long. The attached to the “A” solenoid and the #5
Electrical Connector three pole plug has two leads 101,6 and #1 leads are attached to the “B”
The receptacle is a standard three or (4.0) long and one 177,8 (7.0) long. solenoid. The green wire is used for the
five pole electrical connector with ground connection (#8 screw is
shortened leads and terminals added. All of the wires have Underwriters furnished).
recognized non-solder insulated eyelet
104,3
(4.11)
“W” models ∆
11
Electrical Information
1,5
(0.06)
Seal
M3
5,5
thread 30,5 (0.22)
78,5 106,9 (1.20)
(3.09) (4.21)
92
(3.62)
26,5
27,5 (1.04) 22,5
(1.08) ∅ (0.88)
12
Electrical Information
are not available for hazardous duty a ground wire with customer’s #8 self
type models. tapping screw. Units can be series
grounded if desired. The DG4S4-01 pilot
valve bodies have a cast “ground”
symbol adjacent to the drilled hole.
129,0
(5.08)
104,3 137,4
(4.11) (5.41)
Insta-Plug Option housing to complete the circuit. The Wire leads approximately 177.8 mm
assembly is held together by two slotted (7.00”) long are provided when no lights
The insta-plug consists of the following thumb screws. are specified. Models with lights have
features: terminals inside the receptacle housing.
The top housing is removed form the
Section “A”, a four–pronged self lower “A” housing to break the electrical After initial installation, electrical and
aligning electrical plug secured in a connections to the valve solenoids or hydraulic connections need not be
housing that is mounted on top pressed onto the “A” housing to disturbed when valve with insta–plug
center of the valve body where the complete the circuit. The assembly is is removed.
solenoid leads terminate; or: held together by two slotted thumb
screws. NOTE
A “B” complete insta–plug assembly
that includes the “A” housing on top Solenoids “A” and “B” are identified
A nameplate and solenoid indicator on the plug-in and receptacle
of which rests a similar housing lights are part of the receptacle when
containing the mating receptacle. housing; they correspond with
specified. solenoid identification plate. In case
The two housings are keyed to
assure proper hook–up. of tandem valves (#8 spool and LH
Connections to the electric power are models), the insta-plug is rotated
made through the end of the receptacle 180° and conduit connection is on
The top housing is removed from the housing and can be pre-wired by the
lower (“A”) housing to break the the opposite end.
customer. End location of electrical
electrical connections to the valve conduit port permits space–saving
solenoids, or pressed onto the “A” side-by-side valve mounting.
12,7
(.50) Electrical receptacle
Warning
plate WARNING 8-32 Tapped hole for
customer to connect
ground
126,2 154,9
(4.97) (6.10)
146,8
(5.77)
34,9
PBĆL"
(1.38)
PB" models models 69,8
(2.75)
71,4
Electrical conduit connection is over solenoid on Warning (2.81)
single solenoid models, and over “b” solenoid on
Electrical power must be disconnected before
dual solenoid models. See diagram plate for “b”
removing or replacing this receptacle.
solenoid location.
14
Air Gap Solenoid Pilot Options
Centered Models
144,5
(To order air gap pilot delete “W” in (5.69)
Sol. a Sol. b Clearance to remove
solenoid cover. - each end
model code.) Spring offset, single
57,9
solenoid and spring centered models (2.28)
also available.
Weight @ 44 kg (98 lbs.)
Centered Models
Spring offset, single solenoid and spring Sol. a Sol. b
centered models also available. 45,3
(1.78) 60,5
∅ (2.38) 263,8
Weight @ 45,4 kg (100 lbs.) (10.4)
285 226,6
(11.22) (8.92) 15,2
285 (.60)
(10.92)
173,7
(6.84)
15
Model Code
D03 Pilot Operated Directional Valve
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1 Directional Control Valve 8 Main Stage Spool Control Options 14 Spool indicator switch
(Available on models with high
Subplate mounting; solenoid controlled; 1- Spool stroke length adjustments.
performance pilot DG4V3 only)
pilot operated; sliding spool; 4-way flow 2- Pilot choke adjustments
direction. (DGMFN-5-Y-AW-BW-20) spool S3 - Normally open (available on valves
shift control. with code P* only)
3 - Pilot choke & stroke adjustments. S4 - Normally closed (available on
2 Valve Size 7 - Stroke adjustment “A” port end only valves with code P* only)
1-1/4”valve size NFPA - D10 8 - Stroke adjustment “B” port end only S5 - Free leads (available on valves with
(ISO-4401-10) mounting interface. 2-7 - Pilot choke adjustment & stroke coil type code F only)
adjustment “A” port end only. S6 - LVDT type DC switch with Pg7
2-8 - Pilot choke adjustment & stroke connector plug
3 Spool Types adjustment “B” port end only.
0, 1, 2, 3, 4, 6, 8, 9, 11, 31, 33 & 52 15 Coil type
(See flow rating and tabulation for 9 Pilot pressure
description.) U- ISO 4400
E- External pilot pressure F- Flying lead
Blank - Internal pilot pressure SP1 - Single 6,3 mm spade to IEC 760
4 Spool/Spring Arrangement SP2 - Dual 6,3 mm spade to IEC 760
A -Spring offset 10 Pilot drain
B -Spring centered with solenoid “A” 16 Electrical connections
T- Internal pilot drain
removed. (Code F coil only, see pages 15 & 16)
Blank - External pilot drain
C -Spring centered.
D -Pressure centered. T- Wired terminal block
F - Shift to center from spring offset - PA - Insta-plug male receptacle only
11 Pressure Port Check Valve Option PB - Insta-plug male & female
single solenoid.
N -No-spring detented (pilot valve only) K- 0,34 bar (5 psi) cracking press. receptacle
R- 3,4 bar (50 psi) cracking press. PA3 - NFPA 3-pin connector
S- 5,2 bar (75 psi) cracking press. PA5 - NFPA 5-pin connector
5 Manual Override Operator Blank - Omit if not required Blank - Omit if not required
(For single solenoid models only.)
Omit if not required. 12 Solenoid energization identity 17 Housing
(Code F coil only)
V -Solenoid identification determined by
6 Left Hand Build position of solenoid (solenoid “A” at port W - 1/2 NPT thread wiring housing
“A” end and/or solenoid “B” at port “B” J - 20 mm thread wiring housing
(For single solenoid models only.)
end) Blank - Omit if not required
Omit for right hand assembly (for left
Blank - Standard arrangement for ANSI
hand assembly “b” solenoid used, flow is
B93.9 (energize solenoid “A” for flow
P to B when “b” solenoid is energized) 18 Solenoid indicator lights
P to A port)
for single solenoid “A” and “B” models (Code F coil w/Code T electrical
(Code V for any valve with code 4 or
only. connections only)
code 8 spool)
L - Indicator lights
7 Response type Blank - Omit if not required
13 Flag symbol/Pilot Valve
X- Fast response
DG4V3-60 (NFPA D03) Pilot Valve &
Blank - Standard low shock models
Adapter Plate.
M - Electrical options and features
16
19 Coil identification 21 Pilot valve port orifices 22 Design number
A- 110V/50 Hz Code Orifice Diameter Subject to change. Installation
B- 110V/50 Hz, 120V/60 Hz *00 - Solid plug dimensions remain as shown for designs
C- 220V/50 Hz *03 - 0,30 mm (0.012 in) 90 through 99 and 100 through 109.
D- 230V/50 Hz, 240V/60 Hz *06 - 0,60 mm (0.024 in) 90 – DG4V3S–60 pilot valves
G- 12V DC *08 - 0,80 mm (0.030 in) 100 – DG4V3–60 pilot valves
H- 24V DC *10 - 1,00 mm (0.040 in)
DJ - 98V DC *13 - 1,30 mm (0.050 in)
23 Special Feature
P- 110V DC *15 - 1,50 mm (0.060 in)
*20 - 2,00 mm (0.080 in) EN460 Anti-spin feature for type 4&8 spools.
*23 - 2,30 mm (0.090 in)
20 Pilot valve tank pressure rating Blank - Omit if not required
2 - 10 bar (145 psi) DG4V3-60 with S3, (* = P, T, A, and/or B as required)
S4, or S5 spool indicator switch Click here for more information on the
4 - 70 bar (1000 psi) hazardous model pilot control valve,.
5 - 100 bar (1450 psi) DG4V3S-60
6 - 160 bar (2285 psi) DG4V3-60 with
AC solenoids and optional S6 spool
indicator switch
6 - 207 bar (3000 psi) DG4V3-60 with
DC solenoids and optional S6 spool
indicator switch
17
Installation Dimensions
DG5S4-102C-M-M-WB-90/100
Single & Double Solenoid
Spring Offset,Spring Centered
& No Spring Detented Models
Millimeters (inches)
Pressure port
77 190,5
(3.03) (7.50)
76,2
(3.00)
158,8
(6.25)
Tank port 196,9
(7.75)
79,2
(3.12)
19,1 (.75) R.
114,3
(4.50)
Port A Port B
∅ 19,8 (.781) 6 holes for
mounting. Maximum torque
285 Nm (210 ft.lbs.)
69,9
200 (7.87) AC (2.75)
220 (8.66) DC 49,3
(1.94)
23,0
(.91)
35,1
(1.38)
Test connections
.4375-20 UNF-2B thd.
284,2 193,5
(11.2) (7.62)
218,4
(8.60)
244,3 165,1
(9.62) (6.50)
7,1
(.28)
82,6 65
(2.56) 22,4 35,1
(3.25) 98,6
(.88) (1.38)
288,6 6,4 (3.88)
(9.00) ∅ (.25)
378,0
(14.88)
Gasket surface for mounting.
Sealing rings furnished.
18
Electrical Information
28,50 30,00
(1.12) (1.18)
1. For DC coils the +ve lead(s) must be connected 2. For correct light indication of energized solenoid
to the terminal(s) marked +. When using 3-wire ensure that solenoid leads are correctly connected:
incoming leads to double solenoid valves (i.e. light terminals are common with each outer pair of
common neutral) the inner pair of terminals must solenoid terminals according to the side with + mark.
be interconnected.
Insta-Plug
DG4V-3(S)---FPA---60 a wire housing with external terminals The PBW configuration combines both
DG4V-3(S)---FPBW---60 for machine wire connections. male and female plugs in the wiring
housing for a self-contained plug-in unit.
Vickers 2-part “Insta-Plug” eliminates Captive thumb screws, when loosened,
breaking electrical inputs for valve permit the wire housing to be pulled Optional solenoid indicator lights are
disconnect. A male half is pre-wired to clear of the valve for disconnect. A pre-wired to the female plug. Solenoids
the valve body. The mating plug is inside longer ground post provides first “A” and/or “B” are identified on the
make/last break ground connection. wiring housing.
98,5
71,1 (3.88)
WARNING TAG
(2.80) 69,0
“Electrical power
(2.72)
47,5 must be
ref.
(1.87) disconnected
ref. before removing or
replacing this
receptacle“.
Port A Port A Port B
Port B
The conduit box dimensions used for the PA/BBW type connector are different from
those on the other “F” type coil models.
19
Connection details and model type/model code references
NFPA Connector T3.5.29-1980 0.875-16UN-2A thd. Warning tag:
DG4V-3(S)---FPA3W(L)-**-60 “Electrical power must be
DG4V-3(S)---FPA5W(L)-**-60 16,00 disconnected before removing
DG4V-3---S3-FPA5W(L)-**-60 (0.62) or replacing electrical plug.“
DG4V-3---S4-FPA5W(L)-**-60
1 – lead to
1 – green lead (ground) solenoid 5 – lead to 1 – lead to solenoid B 5 – lead to
solenoid solenoid B
3 – lead 4 – lead 4 – lead to
1 to solenoid 5 capped 5 solenoid A
2 1 1 4
4
3 2 3 2 3
25,4 (1.00)
hex (reference
all types)
20
DIN Standard 43650
Plug-in Connectors
Plug connector Connector can be positioned at 90
(Order separately) intervals on valve by reĆassembling
(ISO4400/DIN 43650) contact holder into appropriate
position inside connector housing.
Cable diameter range: Ø6–10 mm (0.24–0.40)
Wire section range: Ø,5–1,5 mm2 (0.0008–0.0023 in2) Connectors with and without indicator
Terminals: Screw type lights are available (order separately):
Type of protection: IEC144 class IP65, when plugs are fitted correctly to 51
(2.01)
the valves with the interface seals 18 27
(supplied with plugs) in place. (0.71) (1.06)
1,5
(0.06)
Seal
M3
5,5
thread 30,5 (0.22)
(1.20)
87,0
(3.42) 100
(4.00)
26,5
27,5 (1.04) 22,5
(1.08) ∅ (0.88)
21
Optional Features
22
Subplate
Mounting Subplate
DGSM-10-24S-11
304,8
Port connection A (12.0)
266,7
“X” – External pilot 190,5 (10.5)
pressure connection (7.5) 38,1
.8750-14 UNF-2B thd. (1.5)
from rear (2 holes) 150,9
(5.94) .750-10 UNC-2B thd
∅16,7 (.656) 147,6 (6 holes)
(4 holes for mounting) (5.81) 44,5
30,7 (1.75)
36,6 35,1 (1.21) 22,9
(1.44) (1.38) 9,5 (.375) drill (.90)
26,2 (1.03) deep
Port connection B
123,7
(4.87)
28,5 “P” – Pressure connection 25,4
122,2 (1.00)
158,8 (1.12)
(4.81)
(6.25) “Y” – Pilot valve 196,9
drain connection (7.75)
(not required for internally
drained models)
23