Vickers®

Directional Controls

Pilot Operated
Directional Control Valves
DG5S4-10**-53 DG4S4-01-50 Air Gap Pilot Valve
DG5S4-10**-80 DG4S4-01-60 Wet Armature Pilot Valve
DG5S4 -10** -90 DG4V-3S-60 Pilot Valve
DG5S4 -10** -100 DG4V-3-60 Pilot Valve, High Performance
NFPA D10, ISO-4401-10

Released 5/94 669


Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features and Benefits
Functional Symbols
Minimum Pilot Pressure

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Basic Characteristics
Mounting Interface
Shifting Action
Mounting Position
Installation Data
Optional Features
Service Information

DG5S4-10-53/80 Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

DG5S4-10-53/80 Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Flow Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

DG5S4-10-80 Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

DG5S4-10-80 Electrical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

DG5S4-10-53 Air Gap Pilot Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

DG5S4-10-90/100 Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

DG5S4-10-90/100 Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

DG5S4-10-90/100 Electrical Informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

DG5S4-10-90/100 Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Subplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

2
Introduction

General Description Features and Benefits


These valves are generally used to  Suitable for the most demanding
control the direction of flow in a industrial applications with flow
hydraulic circuit. This, in turn, would capacities up to 946 l/min (250
control the direction of movement of a USgpm) and rated pressure of
hydraulic cylinder, or the rotation of a 207 bar (3000 psi).
fluid motor.
 Available with a wide variety of spool
 DG5S4-10**- 90 uses a DG4V-3S-60 and spring arrangements, stroke and
standard D03 pilot valve 100 bar pilot choke adjustments, integral check
(1450 psi). valves, and port orifices.

 DG5S4-10**- 100 uses a DG4V-3-60  Solid cast body and core passages for
high performance D03 pilot valve maximum strength and minimal
207 bar (3000 psi). pressure drop.

 DG5S4-10**- 53 uses a DG5S4-01-50  Designed and backed by Vickers, with


air gap pilot valve. over 70 years as the global leader in
fluid power and motion control.
 DG5S4-10**- 80 uses a DG5S4-01-60
wet armature pilot valve 69 bar
(1000 psi).

 XDG5S4-10**-5* Hazardous Duty.

Functional Symbols
Double Solenoid - Spring centered, Double Solenoid - No-spring, Double Solenoid - Pressure centered,
all spools 0, 2, 6, 9 spools all spools
a A B b a A B b a A B b
     
PR PR
P T drain drain P T P T drain

Single Solenoid - Shift to center, Single Solenoid - Spring offset, Single Solenoid - Spring centered,
all spools 0, 2, 6, 9 spools all spools
A B b A B b A B b
  

P T drain P T drain P T drain

Minimum Pilot Pressure


Shifting P to A Shifting P to B
bar (psi) bar (psi)
Spool Type Flow l/min Pressure Centered All Other Pressure Centered All Other
(USgpm) Models Models Models Models
All Spools 0 5,2 (75) 5,2 (75) 13,8 (200) 5,2 (75)
0, 4, 8 & 9 946 (250) 5,2 (75) 5,2 (75) 13,8 (200) 5,2 (75)
2, 3, 6 & 33 946 (250) 10,3 (150) 10,3 (150) 27,6 (400) 10,3 (150)

 On pressure centered models end covers cannot be interchanged. Pilot pressure is not available through use of integral check valves.

3
General Information
DG5S4-10**-** Pilot Operated Directional Valves

Basic Characteristics Pressure centered models: Valve Internal drain may be used with all
spool is returned to center position valves, however, an integral pressure
Max. pressure: 207 bar (3000 psi) by pilot pressure, when solenoids port check valve (see optional check
Max. flow: 946 l/min (250 USgpm) are de-energized. If pilot pressure valve note) is required for valves using
Max. pressure port T (external drain): fails or falls below the required an internal pilot source with an open
. . . . . . . . . . . . . . . 207 bar (3000 psi) minimum, the valve spool will spring center spool (0, 4, 8 and 9 types) in
Max. pressure port T (internal drain): return to center position. (At spring order to maintain pilot pressure. If an
DG5S4-10**-53 – 69 bar (1000 psi) centered valve flow rates.) external pilot source is used then an
DG5S4-10**-80 – 69 bar (1000 psi) integral check is not required. When
DG5S4-10**-90 – 100 bar (1450 psi) Caution internal pilot drain is required, order
DG5S4-10**-100 – 207 bar (3000 psi) according to model code. (Pressure
Surges of oil in a common tank line
Max. pilot pressure: centered valves not included.)
serving these and other valves can
. . . . . . . . . . . . . . . 207 bar (3000 psi)
be of sufficient magnitude to cause
Weights: - See installation drawings. External: When the possibility of
inadvertent shifting of these valves.
Click here for Fluid Cleanliness This is particularly critical in the pressure surges in the tank line exists,
information. no-spring detented type valves. externally drained valves are
Separate tank lines or a vented recommended. For externally drained
Mounting Interface manifold with a continuous models, the pilot valve drain line must
downward path to tank is necessary. be piped directly to tank through a
ISO 4401-10
surge-free line so there will be no back
NFPA D10
pressure at this drain. (Reference
NOTE
Shifting Action connection “Y”.)
Any sliding spool valve, if held for
Spring centered, pressure centered and long periods of time, may stick and Pressure Centered Drain
spring offset models must be energized not spring return due to fluid residue (external only)
continuously to maintain the shifted formation and therefore, should be External pilot drain explanation above
position. Detented no-spring models cycled periodically to prevent this applies to “Y” drain port. Pressure centered
may be energized momentarily from happening. “W” drain connection must be piped
(approximately 0.1 second). directly to tank through a surge free line so
When used as other than a normal
there will be no back pressure at this drain.
Pressure centered and spring centered 4-way valve, consult your Vickers
models return valve spool to center representative. Optional Features
position when solenoids are de-energized.
Mounting Position  Pressure Centered Valves
 Integral Check Valves
Spring offset models return spool to No-spring detented valves must be
 Fast Response
offset position by pilot pressure when installed with the longitudinal axis
 Electrical Options
solenoid is de-energized. horizontal for good machine reliability.
The mounting position of spring-offset
When no-spring detented models are models is unrestricted provided that the Service Information
de-energized, the pilot and main spools pilot pressure supply is maintained as
remain in the last position attained, required. (Spring offset valves do not Refer to specific Vickers parts drawing
provided there is no shock, vibration, have a spring in the main spool section.) for service parts information. A complete
unusual pressure transients and the parts breakdown is contained in this
spool axis is horizontal. If pilot pressure Installation Data drawing.
fails or falls below the minimum, the Order by literature number.
Pilot Valve Drain
main spool will spring center (at spring DG5S4-10*(A/B/C/F/N)-*-90/100 . . I-3890-S
Internal: To provide maximum flow
centered flow rates) and cannot drift to DG5S4-10*(A/B/C/N)-*-80 . . . . . . . . I-3883-S
without malfunction, pilot pressure of
reversal of flow (pilot stage remains in DG5S4-10*(A/B/C/N)-*-5* . . . . . . . . I-3624-S
internally drained valves must always
detented position). DG5S4(L)-10*D(X)-*-5* . . . . . . . . . . I-3625-S
exceed tank line back pressure by a
DG5S4-10**-**DC-5* . . . . . . . . . . . . I-3499-S
minimum of 5,2 bar (75 psi) for spool
Caution XDG5S4-10**-5* . . . . . . . . . . . . . . . . I-3501-S
types 0, 4, 8 & 9 and a minimum of 10,3
Because of this, flow conditions of bar (150 psi) for all other spools.
the spring centered position must be
selected with care, both for the effect
on the direction of the flow, and the
pilot pressure. (The “9” main spool
will not ensure sufficient pilot
pressure in the center position.)
4
Model Code
D05 Pilot Operated Directional Valves

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 Special Solenoid Features 8 Spool/Spring Arrangement 14 Pressure Port Check Valve Option
X- Solenoids for hazardous A -Spring offset K- 0,34 bar (5 psi) cracking press.
locations B -Spring centered with solenoid “A” R- 3,4 bar (50 psi) cracking press.
XM - Solenoids for mining applications removed. S- 5,2 bar (75 psi) cracking press.
Blank - Omit if not required. C -Spring centered. Blank - Omit if not required
D -Pressure centered.
Note: “X” or “XM” not available on plug-in type valves
or with solenoid indicator lights. F - Shift to center from spring offset -
single solenoid. 15 Wet Armature Solenoids
N -No-spring detented (pilot valve only) W - Wet armature solenoids &
2 Electrical Plug-in Options non-serviceable core tubes.
PB - Insta-plug (male & female 9 Pilot Pressure
receptacle).
(required for pressure centered ”D” 16 DIN 43650 Std. Electric Plug
PA3 - NFPA 3-pin conduit connector.
models)
PA5 - NFPA 5-pin conduit connector. Blank - Omit if not required.
Use “W” wiring housing in model A -14-69 bar (200-1000 psi)
code with connector. B -69-138 bar (1000-2000 psi)
Blank - Omit if not required. Omit for 138-207 bar (2000-3000 psi) 17 Electrical Service
Wet armature solenoids:
3 Directional Control Valve 10 Fast Response B - 115/120 V - 60 Hz & 110 V - 50 Hz
(omit for standard low shock models) D - 230 V - 60 Hz & 220/230 V - 50 Hz
Subplate mounting; solenoid controlled; F - 6 V DC
Note: Not available with pressure centered “D” and
pilot operated; sliding spool; 4-way flow “DB” models. G - 12 V DC
direction. H - 24 V DC
Air Gap solenoids:
11 Main Stage Spool Control Options Blank for standard 115V-60 Hz.
4 Solenoid Indicator Lights
1- Spool stroke length adjustments. Specify non-standard voltages
(omit if not required) (i.e. 230V-60 Hz, 24V DC, etc.)
2- Pilot choke adjustments
(DGMFN-5-Y-AW-BW-20) spool
5 “W” Wiring Housing Option shift control.
3 - Pilot choke & stroke adjustments.
18 Design Number
6 Valve Size 7 - Stroke adjustment “A” port end only Subject to change.
8 - Stroke adjustment “B” port end only -53 design uses a DG4S4-01-50 Air Gap
1-1/4”valve size NFPA - D10 2-7 - Pilot choke adjustment & stroke pilot.
(ISO-4401-10) mounting interface. adjustment “A” port end only. -80 design uses a DG4S4-01-60 Wet
2-8 - Pilot choke adjustment & stroke Armature pilot.
7 Spool Types adjustment “B” port end only.

0, 1, 2, 3, 4, 6, 8, 9, 11, 31, 33 & 52 19 LH - Left Hand Assembly


(See flow rating and tabulation for 12 External Pilot Pressure
Omit for right hand assembly (“b”
description.) (omit for internal pilot pressure
solenoid used - flow is P to B when “b”
models)
solenoid is energized). For single
solenoid “A” and “B” models only.
13 Internal Pilot Drain
(omit for external pilot drain models)
20 Special Feature
S534 Anti-spin feature for type 4&8 spools.

5
Pressure Drop

Pressure Drop bar (psi) @ 473 l/min (125 USgpm)


1. Figures in the pressure drop
Spool Type & P!T
Description P!A B!T P!B A!T chart give approximate pressure
Center Position on Center
A B
drop (∆P) when passing 473
Open center 3,10 5,03 3,52 4,48 3,79 l/min (125 USgpm) flow (Q) of
“0”
all ports (45) (73) (51) (65) (55) 21 cSt (100 SUS) fluid(s) having
P T
.865 specific gravity.
A B
Open center 3,10 5,72 3,79 4,48 15,2
“1” 2. For any other flow rate (Q1), the
P&A (45) (83) (55) (65) (220)
P T pressure drop (∆P1) will be
AB
Closed center 3,79 5,72 3,79 5,24 approximately: ∆P1 =
“2” all ports (55) (83) (55) (76)
– ∆P(Q1/Q)2
P T
A B 3. For any other viscosity(s), the
Closed P & B 3,79 5,72 3,79 3,31 pressure drop (∆P), will
“3” –
A open to T (55) (83) (55) (48) change as follows:
P T
AB Tandem -
5,52 10,3 5,52 11,7 5,52
“4” Closed Viscosity
Crossover (80) (150) (80) (170) (80) cSt 14 32 43 54 65 76 86
P T
(SUS) (75)(150) (200) (250) (300) (350) (400)
AB
Closed center 3,79 5,17 3,79 3,17 % of DP
“6” –
P only (55) (75) (55) (46) (Approx.) 93 111 119 126 132 137 141
P T
AB Tandem -
Open 4,27 8,41 4,34 9,51 5,52
“8”
Crossover (62) (122) (63) (138) (80) 4. For any other specific gravity
P T
A B Open center (G1)*, the pressure drop (∆P1) will
partial - 3,17 5,17 3,45 4,83 27,6 be approximately:
“9”
all ports (46) (75) (50) (70) (400) ∆P1 = ∆P(G1/G)
P T
A B * Specific gravity of fluid may be obtained from its
Open center 3,79 5,03 3,52 5,24 15,2 producer. The value is higher for fire-resistant
“11” fluids than for oil.
P&B (55) (73) (51) (76) (220)
P T
AB
“31” Closed P & A 3,79 3,31 3,79 5,72

P T
B open to T (55) (48) (55) (83)
A B
Closed center 3,79 5,72 3,79 5,24
“33” –
bleed A & B (55) (83) (55) (76)
P T
AB
Closed center 3,79 Contact your 3,79 5,24
“52” Vickers rep- –
all ports (55) resentative (55) (76)
P T
Note
When solenoid “a” is energized, flow is always P to A. When solenoid “b” is energized, flow is
always P to B. This is in accordance with the ANSI-B93.9 standard. Standard spring offset
valves are assembled right hand, such that flow is P to A in the spring offset position
(solenoid is de-energized). Solenoid “a” and “b” are identified on the diagram plate.

6
Flow Ratings

Pressure Drop Across Total must be greater than minimum determined from pressure drop chart for
bar/psi for good machine reliability. standard valve and adding pressure
Check Valve drop induced by check valve (see
Total pressure drop is determined from To determine check valve cracking graph). Total must be greater than the
the pressure drop induced by check pressure needed to provide pilot minimum for good machine reliability.
valve and other sources. (See graph, pressure, calculate total pressure drop (See pilot pressure and integral check
pilot pressure and integral valve notes.) through valve (P to T) on center at valve notes.)
minimum flow. Total pressure drop is

Flow - USgpm
10 20 30 40 50 60 70 80 90 100 110 120 130 140
11,0 160

9,7 140
Pressure Drop - bar

Pressure Drop - psi


8,3 120

6,9 100
“S” Model

5,5 80
“R” Model
4,1 60

2,6 40
“K” Model
1,4 20

0 0
38 76 114 151 189 227 265 303 341 379 416 454 492 530
Flow - l/min.

Flow Ratings
Recommended Flow Maximum Flow
Valve Type Spool Type Capacity l/min (USgpm) without Malfunction
l/min (USgpm) @ bar (psi)
No-spring detented 0, 2, 6 & 9 
Spring centered & 0, 4 & 8  473 (125) 946 (250) @ 207 (3000)
Shift to center 2, 3, 6, 31 & 33 
322 (85) @ 207 (3000)
1, 9 & 11 322 (85) 473 (125) @ 138 (2000)
568 (150) @ 69 (1000)
Spring offset 0, 2, 6 & 9 
Pressure centered 1, 0, 2, 3, 4, 6, 8, 9, 11, 473 (125) 946 (250) @ 207 (3000)
31 & 33 

 As system flow increases the minimum pilot pressure required increases. These spools will operate satisfactorily in excess of
946 l/min (250 USgpm) with higher pilot pressures.
NOTE: For the type 52 spool flow recommendations contact your Vickers representative.
 Fast valve switching of large oil volumes, without adequate decompression circuitry, can develop instantaneous flows well
above the maximum ratings. The type 8 spool may spin within the body, causing unusual valve body bore wear when applied in
this type of circuit. With this and other spool types, valve malfunction might occur. Where these applications exist use the DG5S4-10**-S534
special designator for the 4C and 8C anti-spin spools/spring.

7
Installation Dimensions

DG5S4-102C-WB-80
Double Solenoid No Spring Detented
& Spring Centered Models
Millimeters (inches)
Weight @ 45,4 kg (100 lbs.)

Pressure port
77 190,5
(3.03) (7.50) Pilot port Y
76,2
(3.00)

158,8
(6.25)
Tank port 196,9
(7.75)

79,2
(3.12)

Pilot port X
19,1 (.75) R.
114,3
(4.50)
Port A Port B
∅ 19,8 (.781) 6 holes for
mounting. Maximum torque
285 Nm (210 ft.lbs.)

241,3 69,9
(9.50) (2.75)
35,1
(1.38)

Test connections
.4375-20 UNF-2B thd.

201,2
(7.92)
258,3 235
(10.17) (9.25)

252 165,1
(9.92) (6.50)

7,1
(.28)

82,6 65
(2.56) 22,4 35,1
(3.25) 98,6
(.88) (1.38)
288,6 6,4 (3.88)
(9.00) ∅ (.25)
378,0
(14.88)

Gasket surface for mounting.


Sealing rings furnished.

8
Installation Dimensions

173,8 (6.84) AC
Single Solenoid - Spring 212,4 (8.36) DC
Offset, Single Solenoid 45,3
(1.78)
Spring Centered & Shift to
Center Models
Millimeters (inches)
Weight @ 44 kg (97 lbs.)
263,8
(10.4)

Mounting Surface

DG5S4–10*D
Pressure Centered Pilot
Operated Models
This option provides faster spring
centering time by using pilot pressure to 124
center the spool. The centering springs 263,8
(4.88)
(10.4)
are used in addition to pilot pressure to
insure positive centering of the spool.
The valve spool is returned to center
position by pilot pressure and centering
springs. If pilot pressure fails or falls
below the required minimum, the spool
will return to center position at minimum
pilot pressure flow rates for pressure 446
centered valves. (17.56)

DGMFN-5-Y-A1W-B1W-30
Pilot Choke
Pilot choke is adjusted by backing off
Nut 13,0 (.51)
locknuts and turning adjusting screws across flats
inward (clockwise) to decrease rate of 50,8
M8 x 1.0 thread (2.00)
spool travel and outward
(counterclockwise) to increase the rate. 22,1
Pilot oil for models with this feature (.87)
Pilot choke
should be taken from a source having a 302,8
constant pressure. See spool control (11.92)
Screwdriver slot
modifications in model code.

Stroke Adjustments
Stroke Stroke
Stroke adjustment limits movement of adjustment adjustment
the main stage spool. Backing off the 63,5
jam nut and turning the adjusting screw (2.50)
inward (clockwise) decreases spool
stroke. See spool control modifications 256,7 256,7
in model code. (10.11) (10.11)

9
Electrical Information
Solenoid Energizing
When solenoid “A” is energized, flow is
Click here for information on
always P to A. When solenoid “B” is
DG4V3-60 (M in model code) optional
energized, flow is always P to B. This is pilot.
in accordance with the ANSI-B93.9
standard. Spring offset valves as shown
(not LH) port P to A in the offset
position. Solenoids “A” and “B” are
identified on the diagram plate on the
side of the pilot valve.

Wet Armature Type


Solenoids (Standard)
DG5S4-102A-W-B-5* - (DG4S4-01 pilot)

Solenoid Energizing

Solenoid Solenoid
Identification Voltage Inrush Amps Holding Amps
Letter Rating (rms) (rms) Holding Watts
B 120V AC 60 Hz 3.80 0.69 35
110V AC 50 Hz 4.10 0.85 33
D 240V AC 60 Hz 2.10 0.34 36
220V AC 50 Hz 2.30 0.45 34
ED 240V AC 50 Hz 1.85 0.27 28
A 110V AC 50 Hz 3.80 0.63 29
C 220V AC 50 Hz 2.00 0.30 28
G 12V DC 3.67 44
H 24V DC 1.83 44
J 48V DC – 0.92 44
X 250V DC 0.17 44
DP 125V DC 0.35 44

Solenoid Current
115V-60 Hz solenoids are standard.
Specify in model number if other than
115V-60 Hz service is desired. See
model code.

Solenoid Current
Approximate Maximum Inrush Amps* Holding Amps Holding Watts
115V AC - 60 Hz 5.1 .61 –
115V AC - 50/60 Hz (50) 3.25 - 60 4.97 (50) .56 - 60 .59 –
230V AC - 60 Hz 2.55 .32 –
460V AC - 60 Hz 1.27 .16 –
6V DC – – 24
12V DC – – 24
24V DC – – 24

10
Electrical Information

NFPA Hydraulic Valve The five pole plug has four leads 101,6 terminals. The #4 and #2 leads are
(4.0) long and one 177,8 (7.0) long. The attached to the “A” solenoid and the #5
Electrical Connector three pole plug has two leads 101,6 and #1 leads are attached to the “B”
The receptacle is a standard three or (4.0) long and one 177,8 (7.0) long. solenoid. The green wire is used for the
five pole electrical connector with ground connection (#8 screw is
shortened leads and terminals added. All of the wires have Underwriters furnished).
recognized non-solder insulated eyelet

Electrical Connector Plug


Millimeters (inches)
103,5
65,4
14,2 (4.08)
(2.58)
32,7 (.56)
(1.29)

.8750-16 Warning tag:


WARNING
UN-2A Thd. Electrical power must
be disconnected
before removing or
Wiring decal replacing this
25,4
Hex 137,4 receptacle.
(1.00)
(5.41)
129,0
(5.08)

104,3
(4.11)

“W” models ∆

“LW” models  2 lead ( to monitor switch,


common, black lead)
1 lead to solenoid
1 lead to solenoid B" 5 lead to solenoid
1 green lead (ground) 1 lead to solenoid
5 lead to
3 lead to solenoid 5 lead to solenoid
solenoid B" 4 lead to monitor
4 lead capped 4 lead to switch, N.O.,
solenoid A" plain lead

3 green lead (ground) 3 green lead (ground) 3 green lead


2 lead to solenoid
2 lead capped 2 lead to solenoid A" (ground)

PA3DG4S*W/LW-01**-*-5* PA5DG4S*W/LW-01**-*-5* PA5DG4S4W/LW-01**-*-5* SPA5DG4S4W/LW-01**-*-5*

A models A models C models A models only


C models C models N models
F models F models

Electrical connection is over solenoid


on single solenoid models, and over “b”
solenoid on dual solenoid models. See
diagram plate for “b” solenoid location.

Electrical rating 600 volts, 3 pole, 10


amps and 5 pole, 8 amps. The female
portable plug to be furnished by
customer.

11
Electrical Information

DIN Standard 43650


Plug-in Coils
Plug connector Connector can be positioned at 90
(Order separately) intervals on valve by reĆassembling
(ISO4400/DIN 43650) contact holder into appropriate
position inside connector housing.
Cable diameter range . . . Ø6–10 mm (0.24–0.40)
Connectors with and without indicator
Wire section range . . . . . Ø,5–1,5 mm2 (0.0008–0.0023 in2)
lights are available (Order separately):
Terminals . . . . . . . . . . . . . . Screw type
Type of protection . . . . . . IEC144 class IP65, when plugs are fitted 51
(2.01)
correctly to the valves with the interface seals 18 27
(supplied with plugs) in place.  (0.71) (1.06)

1,5
(0.06)
Seal

M3
5,5
thread  30,5 (0.22)
78,5 106,9 (1.20)
(3.09) (4.21)

92
(3.62)

26,5
27,5 (1.04) 22,5
(1.08) ∅ (0.88)

Voltage Gray - Black -


Receptacle (AC or DC)
A" sol. B" sol.
Without
710776 710775
lights
12Ć24 977467 977466
With
100Ć125 977469 977468
lights
200Ć240 977471 977470

12
Electrical Information

Electrical Accessories & Wiring Housing (W) NOTE


The wiring housing (W) is a 39,6 (1.56) Electrical accessories shown are not
Options high riser block mounted on top of the available with hazardous duty type
Wiring Housing - Lights for pilot valve. A 1/2” NPTF thread models identified by model prefix “X”
DG4S4-01-60 Valves connection is provided in one end of the or “XM”.
The electrical accessories options are housing. The housing can be rotated
available on the basic DG4S4-01-* 180 if the connection is required on
Electrical Diagram
directional control and all valves that the opposite end. This connection will
use the DG4S4-01* as pilot valve. An readily accept common electrical quick
Elect. Circuit
electrical wiring diagram is provided on disconnect assemblies on the market. Diagram
the bottom of the nameplate, and shown The wiring housing is available with
below, for installation instructions. most options. Elect.
Input Indicator
Light
term
Lights (L) Grounding strip Sol.
Lights are “on” when there is voltage A drilled hole is provided for a #8 self
across the solenoids. (Only double lights tapping screw which will permit a ground
are available.) Lights are available with wire to be secured to the pilot valve
most options. (The light option has an body. Elect. Circuit
Diagram
integral terminal strip) and are for use
Repeat for
with 100 through 125 and 192 through Wiring housing “W” has a cast hole second solenoid
233 volt service solenoids only. They (see below) which also permits securing Installation Wiring

are not available for hazardous duty a ground wire with customer’s #8 self
type models. tapping screw. Units can be series
grounded if desired. The DG4S4-01 pilot
valve bodies have a cast “ground”
symbol adjacent to the drilled hole.

Lights & Wiring Housing


W, LW Models
Millimeters (inches) .50 NPTF Dryseal thread.
65,4 LW" models For type 4 & 8 spools conduit
connection location on end
(2.58)
32,7
W" models of W" housing is reversed.
(1.29)

129,0
(5.08)

104,3 137,4
(4.11) (5.41)

 Receptacle will be prewired directly insulated with black electrical tape.


to the terminals on the solenoid (For exception see note “ ”).
indicator light package.
(For exception see note  "). For models with monitor switch,
wires to be supplied and connected by
∆ Receptacle will be prewired to the customer.
solenoid eyelets. The connection will be
made via No. 6 screws and nuts
13
Electrical Information

Insta-Plug Option housing to complete the circuit. The Wire leads approximately 177.8 mm
assembly is held together by two slotted (7.00”) long are provided when no lights
The insta-plug consists of the following thumb screws. are specified. Models with lights have
features: terminals inside the receptacle housing.
The top housing is removed form the
Section “A”, a four–pronged self lower “A” housing to break the electrical After initial installation, electrical and
aligning electrical plug secured in a connections to the valve solenoids or hydraulic connections need not be
housing that is mounted on top pressed onto the “A” housing to disturbed when valve with insta–plug
center of the valve body where the complete the circuit. The assembly is is removed.
solenoid leads terminate; or: held together by two slotted thumb
screws. NOTE
A “B” complete insta–plug assembly
that includes the “A” housing on top Solenoids “A” and “B” are identified
A nameplate and solenoid indicator on the plug-in and receptacle
of which rests a similar housing lights are part of the receptacle when
containing the mating receptacle. housing; they correspond with
specified. solenoid identification plate. In case
The two housings are keyed to
assure proper hook–up. of tandem valves (#8 spool and LH
Connections to the electric power are models), the insta-plug is rotated
made through the end of the receptacle 180° and conduit connection is on
The top housing is removed from the housing and can be pre-wired by the
lower (“A”) housing to break the the opposite end.
customer. End location of electrical
electrical connections to the valve conduit port permits space–saving
solenoids, or pressed onto the “A” side-by-side valve mounting.

Lights & Wiring Housing


Insta-Plug
4 leads approx. 178 mm (7.00”) long. White leads are connected to Insta-plug without lights
solenoid “a” and black leads are connected to solenoid “b”. (See
Millimeters (inches) diagram plate) For type “8” spool and left hand models, conduit 88,9
(3.50)
connection location is reversed.
44,4
(1.75)

20,2 Clearance required to remove


Stripped and (.80) female receptacle 63,5
twisted wire (2.50)

12,7
(.50) Electrical receptacle
Warning
plate  WARNING 8-32 Tapped hole for
customer to connect
ground

Center line of .5000 160,3 Insta-plug with solenoid


NPTF Dryseal thread (6.31) indicator lights

126,2 154,9
(4.97) (6.10)
146,8
(5.77)

34,9
PBĆL"
(1.38)
PB" models models 69,8
(2.75)
71,4
Electrical conduit connection is over solenoid on  Warning (2.81)
single solenoid models, and over “b” solenoid on
Electrical power must be disconnected before
dual solenoid models. See diagram plate for “b”
removing or replacing this receptacle.
solenoid location.

14
Air Gap Solenoid Pilot Options

AC Solenoids (double) - 261,9


(10.3)
No-spring Detented,
131
Pressure Centered & Spring (5.16)

Centered Models
144,5
(To order air gap pilot delete “W” in (5.69)
Sol. a Sol. b Clearance to remove
solenoid cover. - each end
model code.) Spring offset, single
57,9
solenoid and spring centered models (2.28)
also available.
Weight @ 44 kg (98 lbs.)

DC Solenoids (double) - 306,3


167,4
(12.06)
No-spring Detented, (6.59) Clearance to remove
153,2 solenoid cover. - each end
Pressure Centered & Spring (6.03)

Centered Models
Spring offset, single solenoid and spring Sol. a Sol. b
centered models also available. 45,3
(1.78) 60,5
∅ (2.38) 263,8
Weight @ 45,4 kg (100 lbs.) (10.4)

Hazardous Locations (X) &


Mining Applications (XM) XM - Valves for mining applications are
built to MSHA schedule 2G - file X/P
Spring offset, single solenoid and spring 837. For specific models covered by
centered models also available. this certification contact your Vickers
X - Valves for hazardous locations are representative. Clearance to
117,3
240,5 (4.62)
Underwriters approved - Class 1 (9.47)
remove solenoid
Group D, Class 2 Group E - F - G, for - each end. 95,3
Electrical Conduit 116,6
Connection (3.75)
115 and 230 V, 60 Hz service only. (4.59) 58,7
1/2 NPTF thd. (2.31)

Weight @ 47 kg (104 lbs.)


328,7 333
(12.94) (13.11)

285 226,6
(11.22) (8.92) 15,2
285 (.60)
(10.92)

173,7
(6.84)

15
Model Code
D03 Pilot Operated Directional Valve

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

1 Directional Control Valve 8 Main Stage Spool Control Options 14 Spool indicator switch
(Available on models with high
Subplate mounting; solenoid controlled; 1- Spool stroke length adjustments.
performance pilot DG4V3 only)
pilot operated; sliding spool; 4-way flow 2- Pilot choke adjustments
direction. (DGMFN-5-Y-AW-BW-20) spool S3 - Normally open (available on valves
shift control. with code P* only)
3 - Pilot choke & stroke adjustments. S4 - Normally closed (available on
2 Valve Size 7 - Stroke adjustment “A” port end only valves with code P* only)
1-1/4”valve size NFPA - D10 8 - Stroke adjustment “B” port end only S5 - Free leads (available on valves with
(ISO-4401-10) mounting interface. 2-7 - Pilot choke adjustment & stroke coil type code F only)
adjustment “A” port end only. S6 - LVDT type DC switch with Pg7
2-8 - Pilot choke adjustment & stroke connector plug
3 Spool Types adjustment “B” port end only.
0, 1, 2, 3, 4, 6, 8, 9, 11, 31, 33 & 52 15 Coil type
(See flow rating and tabulation for 9 Pilot pressure
description.) U- ISO 4400
E- External pilot pressure F- Flying lead
Blank - Internal pilot pressure SP1 - Single 6,3 mm spade to IEC 760
4 Spool/Spring Arrangement SP2 - Dual 6,3 mm spade to IEC 760
A -Spring offset 10 Pilot drain
B -Spring centered with solenoid “A” 16 Electrical connections
T- Internal pilot drain
removed. (Code F coil only, see pages 15 & 16)
Blank - External pilot drain
C -Spring centered.
D -Pressure centered. T- Wired terminal block
F - Shift to center from spring offset - PA - Insta-plug male receptacle only
11 Pressure Port Check Valve Option PB - Insta-plug male & female
single solenoid.
N -No-spring detented (pilot valve only) K- 0,34 bar (5 psi) cracking press. receptacle
R- 3,4 bar (50 psi) cracking press. PA3 - NFPA 3-pin connector
S- 5,2 bar (75 psi) cracking press. PA5 - NFPA 5-pin connector
5 Manual Override Operator Blank - Omit if not required Blank - Omit if not required
(For single solenoid models only.)
Omit if not required. 12 Solenoid energization identity 17 Housing
(Code F coil only)
V -Solenoid identification determined by
6 Left Hand Build position of solenoid (solenoid “A” at port W - 1/2 NPT thread wiring housing
“A” end and/or solenoid “B” at port “B” J - 20 mm thread wiring housing
(For single solenoid models only.)
end) Blank - Omit if not required
Omit for right hand assembly (for left
Blank - Standard arrangement for ANSI
hand assembly “b” solenoid used, flow is
B93.9 (energize solenoid “A” for flow
P to B when “b” solenoid is energized) 18 Solenoid indicator lights
P to A port)
for single solenoid “A” and “B” models (Code F coil w/Code T electrical
(Code V for any valve with code 4 or
only. connections only)
code 8 spool)
L - Indicator lights
7 Response type Blank - Omit if not required
13 Flag symbol/Pilot Valve
X- Fast response
DG4V3-60 (NFPA D03) Pilot Valve &
Blank - Standard low shock models
Adapter Plate.
M - Electrical options and features

16
19 Coil identification 21 Pilot valve port orifices 22 Design number
A- 110V/50 Hz Code Orifice Diameter Subject to change. Installation
B- 110V/50 Hz, 120V/60 Hz *00 - Solid plug dimensions remain as shown for designs
C- 220V/50 Hz *03 - 0,30 mm (0.012 in) 90 through 99 and 100 through 109.
D- 230V/50 Hz, 240V/60 Hz *06 - 0,60 mm (0.024 in) 90 – DG4V3S–60 pilot valves
G- 12V DC *08 - 0,80 mm (0.030 in) 100 – DG4V3–60 pilot valves
H- 24V DC *10 - 1,00 mm (0.040 in)
DJ - 98V DC *13 - 1,30 mm (0.050 in)
23 Special Feature
P- 110V DC *15 - 1,50 mm (0.060 in)
*20 - 2,00 mm (0.080 in) EN460 Anti-spin feature for type 4&8 spools.
*23 - 2,30 mm (0.090 in)
20 Pilot valve tank pressure rating Blank - Omit if not required
2 - 10 bar (145 psi) DG4V3-60 with S3, (* = P, T, A, and/or B as required)
S4, or S5 spool indicator switch Click here for more information on the
4 - 70 bar (1000 psi) hazardous model pilot control valve,.
5 - 100 bar (1450 psi) DG4V3S-60
6 - 160 bar (2285 psi) DG4V3-60 with
AC solenoids and optional S6 spool
indicator switch
6 - 207 bar (3000 psi) DG4V3-60 with
DC solenoids and optional S6 spool
indicator switch

17
Installation Dimensions

DG5S4-102C-M-M-WB-90/100
Single & Double Solenoid
Spring Offset,Spring Centered
& No Spring Detented Models
Millimeters (inches)
Pressure port
77 190,5
(3.03) (7.50)
76,2
(3.00)

158,8
(6.25)
Tank port 196,9
(7.75)

79,2
(3.12)

19,1 (.75) R.
114,3
(4.50)
Port A Port B
∅ 19,8 (.781) 6 holes for
mounting. Maximum torque
285 Nm (210 ft.lbs.)

69,9
200 (7.87) AC (2.75)
220 (8.66) DC 49,3
(1.94)
23,0
(.91)

35,1
(1.38)

Test connections
.4375-20 UNF-2B thd.

284,2 193,5
(11.2) (7.62)
218,4
(8.60)

244,3 165,1
(9.62) (6.50)

7,1
(.28)

82,6 65
(2.56) 22,4 35,1
(3.25) 98,6
(.88) (1.38)
288,6 6,4 (3.88)
(9.00) ∅ (.25)
378,0
(14.88)
Gasket surface for mounting.
Sealing rings furnished.

18
Electrical Information

Terminal strip and lights


For valves with type “F” coils.
Dim mm (in.)

Terminal strip Conduit box cover and


(part number nameplate complete with
890345) clips to sealing gasket and 4 screws.
cover and can
be field-fitted
Light assembly is held in place
4 terminal screws M3 x 0,5-6H by end pair of M3 screws; can
M3 x 0,5-6H screws (part number 02-113355) be fitted to terminal strip.
(part number 186006) Connections to solenoid A
2 each end (or B, according to model type)

28,50 30,00
(1.12) (1.18)

Anti-rotation tab ensures


Connections to correct orientation of cover
solenoid B Rubber gasket to junction box.
(or A, according 2 lenses in cover
to model type)

1. For DC coils the +ve lead(s) must be connected 2. For correct light indication of energized solenoid
to the terminal(s) marked +. When using 3-wire ensure that solenoid leads are correctly connected:
incoming leads to double solenoid valves (i.e. light terminals are common with each outer pair of
common neutral) the inner pair of terminals must solenoid terminals according to the side with + mark.
be interconnected.

Insta-Plug
DG4V-3(S)---FPA---60 a wire housing with external terminals The PBW configuration combines both
DG4V-3(S)---FPBW---60 for machine wire connections. male and female plugs in the wiring
housing for a self-contained plug-in unit.
Vickers 2-part “Insta-Plug” eliminates Captive thumb screws, when loosened,
breaking electrical inputs for valve permit the wire housing to be pulled Optional solenoid indicator lights are
disconnect. A male half is pre-wired to clear of the valve for disconnect. A pre-wired to the female plug. Solenoids
the valve body. The mating plug is inside longer ground post provides first “A” and/or “B” are identified on the
make/last break ground connection. wiring housing.

PA configuration PBW configuration


Dim mm (in.)
Customer connection solenoid at port A
16,25 Clearance to remove
end of body to female receptacle plate.
(0.64) M4-6H thd. female receptacle
20,25 (0.79) Customer connection
48,0 solenoid at port B end of
(1.89) body to female receptacle
plate.
89,0
23,1 (0.91) (3.50) Ground connection
24,0 (0.95) in terminal box
(ref.)
15,5 (0.61)
32,50
(1.28)

98,5
71,1 (3.88)
WARNING TAG
(2.80) 69,0
“Electrical power
(2.72)
47,5 must be
ref.
(1.87) disconnected
ref. before removing or
replacing this
receptacle“.
Port A Port A Port B
Port B
The conduit box dimensions used for the PA/BBW type connector are different from
those on the other “F” type coil models.

19
Connection details and model type/model code references
NFPA Connector T3.5.29-1980 0.875-16UN-2A thd. Warning tag:
DG4V-3(S)---FPA3W(L)-**-60 “Electrical power must be
DG4V-3(S)---FPA5W(L)-**-60 16,00 disconnected before removing
DG4V-3---S3-FPA5W(L)-**-60 (0.62) or replacing electrical plug.“
DG4V-3---S4-FPA5W(L)-**-60

The receptacle is a standard three or


five pole connector with shortened leads
and terminals added. The five pole plug
has four leads 101,6 (4.0) long and one
177,8 (7.0) long. The three pole plug
has two leads 101,6 (4.0) long and one 68,65
177,8 (7.0). All wires have underwriters (2.71)
recognized non-solder insulated eyelet
terminals. The green wire is used for the
ground (earth) connection (No. 8 screw
furnished). Valves are supplied
pre-wired.

3 pin connector 5 pin connector 5 pin connector


Use with single solenoid valve Use with single solenoid valve Use with double solenoid valve
Key model code designations: Key model code designations: Key model code designations:
DG4V-3(S)-*A(L)(-**)-(V)M-FPA3W(L) DG4V-3(S)-*A(L)(-**)-(V)M-FPA5W(L) DG4V-3-*A(L)(-**)-(V)M-S4-FPA5W(L)
DG4V-3(S)-*B(L)(-**)-(V)M-FPA3W(L) DG4V-3(S)-*B(L)(-**)-(V)M-FPA5W(L)

1 – lead to
1 – green lead (ground) solenoid 5 – lead to 1 – lead to solenoid B 5 – lead to
solenoid solenoid B
3 – lead 4 – lead 4 – lead to
1 to solenoid 5 capped 5 solenoid A
2 1 1 4
4
3 2 3 2 3
25,4 (1.00)
hex (reference
all types)

2 – lead to solenoid 3 – green lead (ground) 3 – green lead (ground)


2 – lead capped 2 – lead to solenoid A

5 pin connector 5 pin connector


Use with single solenoid valve with S3 Use with single solenoid valve with S4
spool position monitor switch spool position monitor switch
Key model code designations: Key model code designations:
DG4V-3-*A(L)(-**)-(V)M-S3-FPA5W(L) DG4V-3-*A(L)(-**)-(V)M-S4-FPA5W(L)

1 – lead to solenoid 5 – lead to 1 – lead to solenoid


solenoid 5 – lead to solenoid
4 – lead to monitor 4 – lead to monitor
5 switch, n.o. 5 switch, n.c.
1 4 1 4
2 3 2 3

3 – green lead (ground)


2 – lead to monitor switch, common
3 – green lead (ground)
2 – lead to monitor switch, common

20
DIN Standard 43650
Plug-in Connectors
Plug connector Connector can be positioned at 90
(Order separately) intervals on valve by reĆassembling
(ISO4400/DIN 43650) contact holder into appropriate
position inside connector housing.
Cable diameter range: Ø6–10 mm (0.24–0.40)
Wire section range: Ø,5–1,5 mm2 (0.0008–0.0023 in2) Connectors with and without indicator
Terminals: Screw type lights are available (order separately):
Type of protection: IEC144 class IP65, when plugs are fitted correctly to 51
(2.01)
the valves with the interface seals 18 27
(supplied with plugs) in place.  (0.71) (1.06)

1,5
(0.06)
Seal

M3
5,5
thread  30,5 (0.22)
(1.20)
87,0
(3.42) 100
(4.00)

26,5
27,5 (1.04) 22,5
(1.08) ∅ (0.88)

Voltage Gray - Black -


Receptacle (AC or DC)
A" sol. B" sol.
Without
710776 710775
lights
12-24 977467 977466
With
100-125 977469 977468
lights
200-240 977471 977470

21
Optional Features

Pressure Centered Valves Integral Check Valves Fast Response


This option provides more positive For open center spools using internal Use of this option decreases the shift
centering through greater force. pilot pressure and internal pilot drain, time, however, the system shock
Centering springs are used, in addition select appropriate spring model (K, R or generation is increased.
to pilot pressure, to ensure centering S) from “check valve pressure drop vs.
(flow must be within the spring centering flow” curve shown on page 7. The following chart provides shift times
ratings) should pilot pressure fail. for fast response and standard spring
Total pressure drop required is 5,2 bar centered models for various pilot
Springs can be removed by the user if (75 psi), therefore, determine valve ∆P pressures.
not wanted. Pressure centered models (P to T) at the actual application flow
require a minimum of 14 bar (200 psi) rate. Subtract this value from 5,2 bar (75 Typical Shift Time in
for pilot pressure. This pressure is not psi) and call its value “C”. Refer to the Seconds for AC Models
available through use of an integral “check valve pressure drop” curve at the
check valve. application flow rate and select the Pilot Standard Fast
spring model letter whose curve is Pressure Center to Response
The following chart provides centering above the bar (psi) value “C” (See “pilot bar (psi) “A” or “B” Center to
times for pressure centered models. pressure” note for external drain “A” or “B”
Centering times for pressure centered models.) 34,5 (500) .120 .060
models are shown with various pilot 69 (1000) .085 .050
pressures Example:
Model selected - DG5S4-100C-T-*-5* 138 (2000) .070 .040
DG5 - Pressure Centering and flow in neutral 189 l/min (50 207 (3000) .055 *
DG Valves USgpm). Assuming no pressure or
pressure surges in the tank line. To Note:
Typical centering times in seconds. All spring centered models require
select proper integral check valve
consider: approximately .125 of a second to
Model Pilot “B” to “A” to
Pressure Center Center ∆P (P to T) from chart = approx. center from either side.
bar (psi) 4 bar (55 psi) at 473 l/min When using the wet armature solenoid
(125 USgpm) operated pilot (“W” in model
10,3 (150) .104 .144 code) add .010 seconds to the times
DA 17,2 (250) .080 .108 ∆P at 208 l/min (55 USgpm) = 4 bar shown. The DG4V3-60 pilot
69 (1000) .056 .064 (55 psi) (50/125)2 = 0,6 bar (9 psi) is not recommended where fast
response is of concern.
DB 69 (1000) .064 .085
5,2 bar (75 psi) – 0,6 bar (9 psi) =
138 (2000) .060 .080 4,6 bar (66 psi) additional pilot * Because of the high drain line pressure
pressure to be obtained through transients generated during shifting,
D 138 (2000) .065 .092 use of the fast response option is not
207 (3000) .060 .076 integral check valve, value “C”. recommended for pilot pressure exceeding
138 bar (2000 psi). DC shift times will be
Notes: From check valve pressure drop curves approximately three or four times the
for DG5S4-10 series at 189 l/min (50 above AC values.
Above figures for “DA” model are with
fast response option (“X” in model USgpm). 4,6 bar (66 psi) is generated
code). between the R and S check valves.
Fast response option not available with
Select “S” for DG5S4-100C-T-S-W*-5*
“D” or “DB” models.

Above data based on air gap type


solenoid pilot valve. When using the wet
armature solenoid pilot (“W” in model
code) add .010 seconds to the times
shown. Models with the DG4V3-60
pilots (“M” in model code) not
recommended for this feature.

22
Subplate

Subplates & Bolt Kits


Valves, subplates and mounting bolts When subplate is not used, a machined
must be ordered separately. pad must be provided for mounting. Pad
must be flat within 0,0127 mm (.0005
Example: inch) and smooth within 1,6 µm (63
One (1) DG3S-102C-5* Valve microinch). Mounting bolts, when
One (1) DGSM-10-24S-11 Subplate provided by customer, should be SAE
One (1) BKDG10-636 Bolt Kit grade 7 or better.
(bolt length 69,9 (2.75)

Mounting Subplate
DGSM-10-24S-11

304,8
Port connection A (12.0)
266,7
“X” – External pilot 190,5 (10.5)
pressure connection (7.5) 38,1
.8750-14 UNF-2B thd. (1.5)
from rear (2 holes) 150,9
(5.94) .750-10 UNC-2B thd
∅16,7 (.656) 147,6 (6 holes)
(4 holes for mounting) (5.81) 44,5
30,7 (1.75)
36,6 35,1 (1.21) 22,9
(1.44) (1.38) 9,5 (.375) drill (.90)
26,2 (1.03) deep

Port connection B
123,7
(4.87)
28,5 “P” – Pressure connection 25,4
122,2 (1.00)
158,8 (1.12)
(4.81)
(6.25) “Y” – Pilot valve 196,9
drain connection (7.75)
(not required for internally
drained models)

“T” Tank connection 28,6 (1.125) drill


41,1 22,4 (.88) deep
∅28,6 (1.125) (1.62)
(4 holes) - system 75,2 (4 holes)
ports1.875-12 UN-2B thd. (2.96)
(from rear) (4 holes) - system 114,3
(4.5)
connections ∅7,1 (.281) - 7,9 (.31) deep
168,1 (2 holes for rest pins)
(6.62)
168,1
(6.62)

Manifolds or other mounting interface can


be drilled to 33,3 (1.312) dia. Fitting size and fitting
spacing limit the subplate port size to 28,6 (1.125) dia.

23
Application Data

Fluid Cleanliness contacting Vickers, Incorporated. Vickers products, as any components,


Proper fluid condition is essential for Recommendations on filtration and the will operate with apparent satisfaction in
long and satisfactory life of hydraulic selection of products to control fluid fluids with higher cleanliness codes than
components and systems. Hydraulic condition are included in 561. those described. Other manufacturers
fluid must have the correct balance of will often recommend levels above
cleanliness, materials, and additives for Recommended cleanliness levels, using those specified. Experience has shown,
protection against wear of components, petroleum oil under common conditions, however, that life of any hydraulic
elevated viscosity, and inclusion of air. are based on the highest fluid pressure component is shortened in fluids with
levels in the system and are coded in higher cleanliness codes than those
Essential information on the correct the chart below. Fluids other than listed below. These codes have been
methods for treating hydraulic fluid is petroleum, severe service cycles, or proven to provide a long, trouble-free
included in Vickers publication 561 temperature extremes are cause for service life for the products shown,
“Vickers Guide to Systemic adjustment of these cleanliness codes. regardless of the manufacturer.
Contamination Control” available from See Vickers publication 561 for exact
your local Vickers distributor or by details.

System Pressure Level


bar (psi)
Product <70 (<1000) 70-207 (1000-3000) 207+ (3000+)
Vane Pumps – FIxed 20/18/15 19/17/14 18/16/13
Vane Pumps – Variable 18/16/14 17/15/13
Piston Pumps – Fixed 19/17/15 18/16/14 17/15/13
Piston Pumps – Variable 18/16/14 17/15/13 16/14/12
Directional Valves 20/18/15 20/18/15 19/17/14
Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14
CMX Valves 18/16/14 18/16/14 17/15/13
Servo Valves 16/14/11 16/14/11 15/13/10
Proportional Valves 17/15/12 17/15/12 15/13/11
Cylinders 20/18/15 20/18/15 20/18/15
Vane Motors 20/18/15 19/17/14 18/16/13
Axial Piston Motors 19/17/14 18/16/13 17/15/12
Radial Piston Motors 20/18/14 19/17/13 18/16/13

Fluids and Seals


Flourocarbon seals are standard and
are suitable for use with phosphate
ester type fluids or their blends, water
glycol, water-in-oil emulsion fluids and
petroleum oil.