ZED
SS
PT BINTANG INSPEKSINDO INDONESIA
omplek Pergudangan EHA Blok 8-02
‘J. Raya Legok Km 6 No.77, RT 002/001
Bojong Nangka, Kelapa Oua, Tangerang, Indonesia
INSPEKSINDO __Telp : 021 2222 7029
Testing Report
Customer PT Sentra Prima Services Roport Number: BIVTR/1220/001
Address Unimas Garden Regency JL.Imermotors -«‘Totalof Page =: tof 2
1 Blok D 12 & B-06 Weru Sidoaro Date of Recelved 30 November 2020
Date of Tested 01 Desember 2020
Tested for 1: Material Testing Project Name -
Test Method ASTIMASTO: 2018 PO Number iy
Reference Code ASTMA3TO: 2018 Sample Marking: 11.SPS1
Object tobe tested (as received) Unique Code: DXZKK
Description Carbon steel Pipe Test sample, Size: 20 Inch (14.5 mm Thickness), Material Spec: API SL X 65 PSL1
Type of Test ‘Tensile Test Material (Longitudinal)
Testing Machine Used: COMPUTERIZED ELECTRO-HYDROLIC SERVO UNIVERSAL TESTING MACHINE
Model : WAW-1000E, Capacity : 1000 kN
Remarks * Yield Stress taken at 0.2% Offset Method; BBGM : Broke Between Gauge Mark
Environment Temp 25+2°C
Specimen No Tensile 2
Measured Diameter di. (mm) - :
Measured Thickness o (mm) 1408 14.06
Measured Width ‘be (mm) 1262 12.52
Effective Area Ag (mm) 17566 176.03
Yield Load Fp (kN) 89.50 88.78
jeld Strength* Ry (Nimm') 510 504
Ultimate Tensile Load Fin (kN) 99.94 100.20
Ultimate Tensile Strength Rm (Nimm?) 569 569
Gauge Length Lote) 50 50.
Final Gauge Length Lu(mm) 67.88 69.24
Elongation Ac 36.0 385
Final of Area ‘Ay (mm?) __ 49.83 46.71
Reduction of rea Ze) 715 735
Location of Faure Becm Bec
Note: Hasil pengujfan diatas hanya berfeku untuk sampel yang dij
Test Conducted By
Checked By
Witnessed By
‘rests pate ron hve Baan,
‘Agnes Stephani
‘Albertus Tonggak Onny Juniardi
Mr. Firman $ of PT Sentra Prima Services
Mr. Suwanto of PT Pandawa Pasifk indonesia
a
czimont yr bo eedced cr a il scp wh pr on Spee a aay
(114 1A0-B1-Toat et Rev.2,
07.12.2018)
Date of Issued :01 Desember 2020
Approved By
=a
Albertus Tonggak Onny J.
Laboratory Manager
in acoinee wih bo abreast ccrestatn andr Kae sedis Nason (AEC 70852017)PT SENTRA PRIMA SERVICES
1ISPS1-T1
[SampielO 20.11SPSITI [TestDate fen20z0
[Type Fiat Size(mm) haosi2s2
JAo(mm9 175.66 Lote) 50
Lugar 67.88 lA) 360
rz) ris
am(M4Pe) 569
Re@Pay 510
Load(kN\) Load-fatension Curve
70.00
60.00
50.00
40.00
30.00
20.00
0 300 600 900 120 150 180 210 240 270 300
Extension(mm)PT SENTRA PRIMA SERVICES
11.SPS1-T2
[SampielO [20.11SPSIT2 [TesDete hienyeoz0
[Type Fiat Size(mm) 14.06%12.52
[aoc 176.03 Lo(mmy 50
69.24 Ae) 38.5
46.71 2%) 735
100.20 im(MPa) 569
e878 Re(wPe) 504
Load(kN)
1200
Load-Time Curve
108.0
96.00
84.00
72.00
60.00
48.00
36.00
24.00
12.00
0
0 160 320 480 640 800 960 1
2
128
144 160
Time(s)ZEN PT BINTANG INSPEKSINDO INDONESIA
Si) Sete eas, || Sema VIKAN
OO err a Nps ua Tenge, onesie ee ie
INSPEKSINDO_ Telp: 021 22227020 aoe riae
NDONESTA Exnail: marketing @bintanginspeksindo.com
Testing Report
Customer 1 PTSentra Prima Services Roport Number —: BIUTR/220004
Addrees "Unies Garden Regency JL mermotors Total of Page: 2 of2
1 BK D 12 & 6-06 Wars Sidoao Date of Received: 30 November 2020
Date of Tested: 01 Desember 2020
Toate for + Welding Procedure Speccaon ProjectNamo
Test Method 1 APL 104 2013 po ware if see
Reference Code: API 1104: 2013 Sample Marking: 11.8PS1
Objectto be tested (es eceved) Uniquecode:OxzKK
Description : Carbon steel T Joint Pipe to Pipe Test sample, Size: 20 Inch (14.5 mm Thickness) to 4 Inch, Material
Spec: API SLX 65 PSL1 to API SL SCH 120 Grade B
Type of Test Nick Break Test ( Transverse Specimen)
‘Testing Machine Used; COMPUTERIZED ELECTRO-HYDROLIC SERVO UNIVERSAL TESTING MACHINE
ie Model : WAW-1000E, Capacity : 1000 kN
remarks
Testspecimen Width =: 25mm
Teet Specimen Thickness 148 rm
eee Wek Break Nek Brak
Wind of
; wn :
Depth (mm) bai #
Dimansion of Defect
Leng : :
result contd ;
‘Note: Hasil pengujian diatas hanya berfaku untuk sampel yang diy
Test Conducted By = Agnes Stephani
Checked By Albertus Tonggak Onny Juniardi
Witnessed By Mr. Fitman S of PT Sentra Prima Services
‘Mr. Suwanto of PT Pandawa Pasifk Indonesia
Date of Issued :01 Desember 2020
Approved By
ot
Albertus Tonggak Onny J.
Laboratory Manager
‘eres meats hv bon prtmodin carte win he abate ol coco unr Kane esa Nason ISOAEG 170252017)
Decanters eer tan Mec we Bm! Wr Saw he Sarg ae
(148.04 Be 00 Re.2, 0712-2019)