Approvals
Eden E for harsh environments
96 www.jokabsales.com 1-877-268-3700
Gross Automation, 1725 South Johnson Road, New Berlin, WI 53146, www.jokabsales.com, 800-349-5827
Application Examples - Eden
Eden to Detect Position
Adam and Eva has contact only if they
are within 15 mm from each other.
Eden Hidden in
Doors and Hatches
Non-metallic door material
between Adam and Eva allows
signal through.
Mounting - Eden 80
mm
115
Mounting with one protection plate (DA1) mm DA1
for Adam M12 using prewired molded M12
connector.
120
mm
Mounting with two protection plates (DA1) for DA1 x 2
Adam M12 using M12 connector with
glanded cable.
DA2
1-877-268-3700 www.jokabsales.com 97
Gross Automation, 1725 South Johnson Road, New Berlin, WI 53146, www.jokabsales.com, 800-349-5827
Connection of Eden to Vital 1
98 www.jokabsales.com 1-877-268-3700
Gross Automation, 1725 South Johnson Road, New Berlin, WI 53146, www.jokabsales.com, 800-349-5827
Technical Data - Eden
Manufacturer................................. JOKAB SAFETY, Sweden Minimum distance to metal when
Ordering Data.....................................Adam M12, Adam 3 m there is metal on one or more sides.
Adam 10 m, Adam E10, Adam EC, Adam/Eva (1)...................................................................0 mm
Eva, Eva E and Eva EC Adam/Eva (more)..........................................................2.5 mm
(Adam EC and Eva EC can only be ordered together.) Adam EC/Eva EC, Adam E/Eva E (1)..............................0 mm
Safety Category together with Vital Adam EC/Eva EC, Adam E/Eva E (more)........................0 mm
(according to EN 954-1).........................................................4 Minimum Distance between Eden Pairs.................. 50 mm
Color............................................................ yellow and black Material.................................Macromelt (based on polyamid)
(Eden E and Eden EC is also covered by polyurethane)
Weight
Adam M12........................................................................ 30 g Chemical Resistance
Adam 3 m............................................ 220 g (including cable) Macromelt
Adam 10 m.......................................... 650 g (including cable) Good....... cutting oils, vegetable and animal oils, hydrogen
Adam E10 m........................................ 660 g (including cable) peroxide, diluted acids and bases
Adam EC..............................................660 g (including cable) Not recommended........................ alcohol and strong acids
Eva.................................................................................... 26 g PU (Eden E and Eden EC)
Eva E................................................................................. 36 g Good........ cutting oils, vegetable and animal oils,hydrogen
Eva EC...............................................................................36 g peroxide, diluted acids and bases, alcohols
Power Supply..........................17 - 27 VDC, ripple max 10% Not recommended............................ strong oxidating acids
Power Consumption LED on Adam
Adam without info output..............................................45 mA Green................................................. Eva within range, safety
Adam with info output.......................................... max. 55 mA circuit closed (door closed)
Flashing............................................. Eva within range, earlier
Max. Cable Length........................... see Vital Technical Data safety circuit open (door closed)
Ambient Temperature Red.................................................... Eva out of range, safety
Operation........................................................ -40ºC to +70ºC circuit open (door open)
Storage........................................................... -40ºC to +70ºC Fast Flashing........................Eva within 2 mm from maximum
Protection Class sensing distance (door closed)
Eden/Eden E.......................................................... IP67/IP69K Cable.................................... 3 or 10 m, 0/ 5.7 mm, black PVC
Mounting............................. 4 pcs. M4 screws + DA2 spacer 5 x 0.34 mm2 + screen, UL 2464
Max torque 0.5 Nm Connector........................................M12: 5-pin male contact
(screws, not included, should be locked with loctite or similar) Connections
Detection Distance Max Brown (1)................................................................... +24 VDC
Adam/Eva 15 +/- 2 mm......... Flash 2 mm before red position White (2)...................................................... dynamic signal in
Adam/Eva 12 +/- 2 mm......... Flash 2 mm before red position Blue (3)........................................................................0 VDC
Adam/Eva EC 10 +/- 2 mm....Flash 2 mm before red position Black (4)....................................................dynamic signal out
Grey (5)............................................. info output (see below)
Hysteresis.......................................................... approx. 1 mm
Metal may have influence on detection distance. 24 VDC when LED is green or flashing
This can be prevented by protection plates, DA1. (tolerance -2 VDC) 10mA max
0 VDC when LED is red (tolerance +2 VDC)
Life........................................................................ >107 cycles
Warning: Incorrect connection may cause
permanent damage to Adam devices.
12
18
Adam 3 m
Adam 10 m
15
18 Eva
Adam
30 0/ 4.1 25 6.5 M12
(2x)
21
70
90
66
36
60
M12
19 12
Adam E/EC
10 m and Eva
17.5
18
1-877-268-3700 www.jokabsales.com 99
Gross Automation, 1725 South Johnson Road, New Berlin, WI 53146, www.jokabsales.com, 800-349-5827