High-Current and

Generator Switchgear
Reliable and cost-efficient – in every way

Power Transmission and Distribution


Siemens –
Partner of the power plant sector

The growing energy demand calls for As a pioneer for vacuum switching tech- Therefore, generator switchgear from
more and fail-safe power from the nology, Siemens has developed solutions Siemens offers maximum efficiency and
power plants – and the cost pressure and technologies for the reliable trans- safety – on the whole as well as for every
on the market demands a higher ef- mission and distribution of electrical single component, e.g. especially for the
ficiency in the provision of energy. power from power plants to consumers centerpiece of the switchgear, the genera-
for more than 30 years. The resulting tor vacuum circuit-breaker: To guarantee
comprehensive know-how is reflected in availability and performance, high-current
our high-quality solutions and services. and generator switchgear assemblies are
equipped with circuit-breakers that with-
Be it availability, cost-efficiency or safety: stand maximum stress.
As power plant builders or operators you
are confronted with maximum require-
ments at all times. So, it is just reasonable
to expect the same from crucial compo-
nents such as the generator switchgear.

More safety and reliability – from Siemens

With our generator switchgear you are always on the safe side.
Regardless of the switchgear type you decide for, you will obtain:

 H
 igh reliability due to the intelligent and proven switchgear design
and the use of reliable components tested to the standards

 High security of operation due to clear switching operations

 High personal safety due to safety-oriented design of the switchgear

 High cost-efficiency due to maintenance-free or low-maintenance components

2
Switchgear details that pay off:
Our high-current and generator switch- More efficiency –
gear with the proven vacuum switching with powerful circuit-breakers
technology from Siemens is designed to
withstand maximum normal currents,  H igh mechanical stability
featuring durable contact materials,  Low fire load due to omission
an optimized design in respect of cool- of solid insulation
ing as well as maximum mechanical  Without forced cooling up to maximum
stability. The generator circuit-breaker current ratings – thanks to the utilization
meets the severe requirements of the of natural convection
generator circuit-breaker standard  Ecological and, at the same time,
IEEE C37.013, demonstrating its out- operationally safe vacuum switching
standing qualities. technology

This increases the performance, reliability,


and cost-efficiency of the complete
generator switchgear.

3
HIGS 8BK40
Highly integrated Metal-enclosed generator switchgear
generator switchgear with truck-type circuit-breaker

Technical data

Air-insulated, metal-enclosed

For indoor installation

Rated voltage: Max. 17.5 kV


With the highly integrated generator Technical data (95 kV BIL / 38 kV PFWV)
switchgear, Siemens enables more func-
tionality on less space. For the first time, Air-insulated, metal-enclosed Rated short-circuit-breaking current ISC:
the neutral treatment of the generator as 50 kA / 63 kA
For indoor and outdoor installation
well as the auxiliary feeder are integrated Rated normal currents:
in a single generator switchgear. The Rated voltage: Max. 13.8 kV
 Rated normal current of the
switchgear can be installed both indoors (110 kV BIL / 50 kV PFWV)
busbar, max. 5,000 A
and outdoors: close to the generator,
Rated short-circuit-breaking current ISC:  Rated normal current of the
without expensive cabling.
31.5 – 63 kA feeder, max. 5,000 A

All functions are therefore available out Rated normal current: 2,000 – 3,150 A Circuit-breaker:
of one hand – without time-consuming Generator circuit-breaker according
coordination between different suppliers, Circuit-breaker: to IEEE C37.013, or circuit-breaker
which offers considerable cost savings Generator circuit-breaker according according to IEC 62271-100
due to ... to IEEE C37.013, or circuit-breaker
Dimensions (L x W x H):
according to IEC 62271-100
... lower expenditure for: 2,300 x 1,100 x 2,500 mm
 Planning Dimensions (L x W x H):
3,430 x 1,200 x 2,500 mm Equipment (optional):
 Investment  Generator circuit-breaker
 Installation Equipment (optional):  Disconnecting function by means
 Generator circuit-breaker in of truck-type circuit-breaker
… lower demand for: the main transformer feeder  Earthing switch on generator and
 Space  Disconnector in the main transformer side
 Material (cabling) transformer feeder
 Service  Current and voltage transformers
 Earthing switch on generator  Surge arresters
and transformer side
 Surge capacitors
 Current and voltage transformers
 Surge arresters
 Surge capacitors

Options:
 Integrated auxiliary feeder with
disconnector and generator circuit-
breaker or with switch-disconnector
and fuses

4
HB1 HB1 Outdoor HB3
Horizontal busbar switchgear – Horizontal busbar switchgear – Horizontal busbar switchgear –
not phase-segregated not phase-segregated phase-segregated

Technical data Technical data Technical data

Air-insulated, metal-enclosed Air-insulated, metal-enclosed Air-insulated, metal-enclosed

For indoor installation For outdoor installation For indoor and outdoor installation

Rated voltage: Max. 17.5 kV Rated voltage: Max. 17.5 kV Rated voltage: Max. 17.5 kV
(110 kV BIL / 50 kV PFWV) (110 kV BIL / 50 kV PFWV) (110 kV BIL / 50 kV PFWV)

Rated short-circuit-breaking current ISC: Rated short-circuit-breaking current ISC: Rated short-circuit-breaking current ISC:
50 kA / 63 kA / 72 kA 50 kA / 63 kA / 72 kA 50 kA / 63 kA / 72 kA

Rated normal current Rated normal current Rated normal current


(with natural cooling): (with natural cooling): (with natural cooling):
Max. 6,100 A Max. 5,400 A Max. 10,000 A

Circuit-breaker: Circuit-breaker: Circuit-breaker:


Generator circuit-breaker according Generator circuit-breaker according Generator circuit-breaker according
to IEEE C37.013 to IEEE C37.013 to IEEE C37.013

Dimensions (L x W x H): Dimensions (L x W x H): Dimensions (L x W x H):


4,000 x 1,900 x 2,500 mm 6,300 x 1,900 x 2,600 mm 2,900 x 4,040 x 2,400 mm
(can vary depending on the (can vary depending on the (can vary depending on the
equipment) equipment) equipment)

Equipment (optional): Equipment (optional): Equipment (optional):


 Generator circuit-breaker  Generator circuit-breaker  Generator circuit-breaker
 Disconnector  Disconnector  Disconnector
 Earthing switch on generator and  Earthing switch on generator and  Earthing switch on generator and
transformer side transformer side transformer side
 Current and voltage transformers  Current and voltage transformers  Current and voltage transformers
 Surge arresters  Surge arresters  Surge arresters
 Surge capacitors  Surge capacitors  Surge capacitors

Options: Options: Options:


 Integrated SFC starter  Integrated SFC starter  Integrated SFC starter
 Integrated auxiliary feeder, with  Integrated auxiliary feeder, with  Integrated auxiliary feeder, with
generator circuit-breaker or with generator circuit-breaker or with generator circuit-breaker or with
switch-disconnector and fuses switch-disconnector and fuses switch-disconnector and fuses
 Integrated excitation feeder  Integrated excitation feeder  Integrated excitation feeder
 Brake switch  Brake switch  Brake switch

5
Siemens AG If you have any question about Subject to change without prior notice
Power Transmission and Distribution Power Transmission and Distribution, Order no. E50001-U229-A262-X-7600
Printed in Germany
Medium Voltage Division our Customer Support Center is
Dispo 40400
Mozartstraße 31 c available around the clock. GB 071139 101855 WS 1207
D-91052 Erlangen
Germany Tel.: +49 180 / 524 70 00
Fax: +49 180 / 524 24 71
www.siemens.com/energy (Charges depending on provider)

E-mail: support.energy@siemens.com
www.siemens.com/energy-support