Generator Switchgear
Reliable and cost-efficient – in every way
The growing energy demand calls for As a pioneer for vacuum switching tech- Therefore, generator switchgear from
more and fail-safe power from the nology, Siemens has developed solutions Siemens offers maximum efficiency and
power plants – and the cost pressure and technologies for the reliable trans- safety – on the whole as well as for every
on the market demands a higher ef- mission and distribution of electrical single component, e.g. especially for the
ficiency in the provision of energy. power from power plants to consumers centerpiece of the switchgear, the genera-
for more than 30 years. The resulting tor vacuum circuit-breaker: To guarantee
comprehensive know-how is reflected in availability and performance, high-current
our high-quality solutions and services. and generator switchgear assemblies are
equipped with circuit-breakers that with-
Be it availability, cost-efficiency or safety: stand maximum stress.
As power plant builders or operators you
are confronted with maximum require-
ments at all times. So, it is just reasonable
to expect the same from crucial compo-
nents such as the generator switchgear.
With our generator switchgear you are always on the safe side.
Regardless of the switchgear type you decide for, you will obtain:
H
igh reliability due to the intelligent and proven switchgear design
and the use of reliable components tested to the standards
2
Switchgear details that pay off:
Our high-current and generator switch- More efficiency –
gear with the proven vacuum switching with powerful circuit-breakers
technology from Siemens is designed to
withstand maximum normal currents, H igh mechanical stability
featuring durable contact materials, Low fire load due to omission
an optimized design in respect of cool- of solid insulation
ing as well as maximum mechanical Without forced cooling up to maximum
stability. The generator circuit-breaker current ratings – thanks to the utilization
meets the severe requirements of the of natural convection
generator circuit-breaker standard Ecological and, at the same time,
IEEE C37.013, demonstrating its out- operationally safe vacuum switching
standing qualities. technology
3
HIGS 8BK40
Highly integrated Metal-enclosed generator switchgear
generator switchgear with truck-type circuit-breaker
Technical data
Air-insulated, metal-enclosed
All functions are therefore available out Rated normal current: 2,000 – 3,150 A Circuit-breaker:
of one hand – without time-consuming Generator circuit-breaker according
coordination between different suppliers, Circuit-breaker: to IEEE C37.013, or circuit-breaker
which offers considerable cost savings Generator circuit-breaker according according to IEC 62271-100
due to ... to IEEE C37.013, or circuit-breaker
Dimensions (L x W x H):
according to IEC 62271-100
... lower expenditure for: 2,300 x 1,100 x 2,500 mm
Planning Dimensions (L x W x H):
3,430 x 1,200 x 2,500 mm Equipment (optional):
Investment Generator circuit-breaker
Installation Equipment (optional): Disconnecting function by means
Generator circuit-breaker in of truck-type circuit-breaker
… lower demand for: the main transformer feeder Earthing switch on generator and
Space Disconnector in the main transformer side
Material (cabling) transformer feeder
Service Current and voltage transformers
Earthing switch on generator Surge arresters
and transformer side
Surge capacitors
Current and voltage transformers
Surge arresters
Surge capacitors
Options:
Integrated auxiliary feeder with
disconnector and generator circuit-
breaker or with switch-disconnector
and fuses
4
HB1 HB1 Outdoor HB3
Horizontal busbar switchgear – Horizontal busbar switchgear – Horizontal busbar switchgear –
not phase-segregated not phase-segregated phase-segregated
For indoor installation For outdoor installation For indoor and outdoor installation
Rated voltage: Max. 17.5 kV Rated voltage: Max. 17.5 kV Rated voltage: Max. 17.5 kV
(110 kV BIL / 50 kV PFWV) (110 kV BIL / 50 kV PFWV) (110 kV BIL / 50 kV PFWV)
Rated short-circuit-breaking current ISC: Rated short-circuit-breaking current ISC: Rated short-circuit-breaking current ISC:
50 kA / 63 kA / 72 kA 50 kA / 63 kA / 72 kA 50 kA / 63 kA / 72 kA
5
Siemens AG If you have any question about Subject to change without prior notice
Power Transmission and Distribution Power Transmission and Distribution, Order no. E50001-U229-A262-X-7600
Printed in Germany
Medium Voltage Division our Customer Support Center is
Dispo 40400
Mozartstraße 31 c available around the clock. GB 071139 101855 WS 1207
D-91052 Erlangen
Germany Tel.: +49 180 / 524 70 00
Fax: +49 180 / 524 24 71
www.siemens.com/energy (Charges depending on provider)
E-mail: support.energy@siemens.com
www.siemens.com/energy-support
The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases.
The required features should therefore be specified in each individual case at the time of closing the contract.