Technical Advice
Fixing specialists will offer immediate advice and
recommendations over the telephone.
Field Engineers
Are available to offer fixing advice at your office or on site.
Site Testing
Rawl Fixings engineers will conduct site testing to ensure
the appropriate fixing is specified and used. A detailed
report is provided with recommendations.
Contractor Training To ensure that we continue to meet the future requirements of the industry, Rawlplug
Rawl Fixings engineers will be pleased to carry out practical has a policy of continuous product development supported by extensive design and
training for contractors to ensure anchors are installed
correctly. test centre facilities. Rawlplug therefore reserves the right to modify product designs
without prior notice. Rawlplug also reserves the right to modify information contained
Technical Calculation Software within this guide without notifying existing holders of the document. While this
l An innovative calculation CD ROM from Rawl Fixings. document gives guidance relating to the use and nature of the products and
l Allows calculations and product selections to be made
variety of applications, the ultimate responsibility for correct selection of a product for
in concrete.
l Includes both mechanical and chemical anchor a specific application must lie with the customer. Rawlplug recommendations are
made in good faith but do not constitute a guarantee.
solutions.
l For your free CD, please e-mail Rawl Fixings
at technical@rawlplug.co.uk
2 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
Company Profile 4 R-CAS Capsule 46
INTRODUCTION
HIGH PERFORMANCE
BONDED ANCHORS
Rawl Calculation 10 CFS RM50 52
Rawlbolt Eyebolt 38
Rawlbolt Hookbolt 39
Heritage
For 88 years, the Rawlplug brand
has been synonymous with
innovation, reliability and safety in
the development and manufacture
of construction anchors and ancillary
products.
Product Approval
The proven quality and performance of Rawlplug and Rawl Fixings
anchors is demonstrated by the numerous independent approvals that
Rawlplug and Rawl Fixings products carry. In fact, in 1999, Rawlplug
became the first UK manufacturer to obtain European approvals (ETA)
for the R-HPT and R-SPT throughbolt range.
Link - up ®
4 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
COMPANY PROFILE
z Technical seminars
z Distributor training
Background
October 1997 marked the first significant step in the development, selection
and use of structural and safety critical anchor bolts. The European
These parts of the ETAG cover torque controlled anchors such as Rawl R-HPT
and Rawl R-SPT Throughbolts. Adoption of the ETAG 001 marked the first
end users for many years, allowing products to be compared on a like for like
Scope
ETAG 001 covers all structural and safety relevant applications where there
Suitability tests determine the functionality of the anchor under the most
likely and extreme deviations from installation and service conditions. This
The mean ultimate load in all suitability tests must attain a given percentage
of the reference values obtained in the Admissible Service Condition tests and
CE Marking
all test results must have limited scatter. To affix CE marking to an anchor, it must have two important documents:
published and accepted performance. Only then can an anchor possess CE marking.
6 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWL APPROVALS
Benefits
ETAG approved and CE marked products will enable specifiers, distributors,
contractors and end users to have the utmost confidence in specifying, selling
and installing these products, where safety and reliability are paramount and
Rawl Fixings
Rawlplug and Rawl Fixings have continued to develop their range of products
to meet these requirements to ensure their customers can satisfy current and
future market needs with new, improved anchors with increased safety.
Rawl Fixings has been awarded ETA approvals and CE marking for the new
range of Rawl R-HPT and Rawl R-SPT Throughbolts i.e. ETA’s 98/0003 and
Rawlplug and Rawl Fixings were the first UK manufacturer of any construction
This ensures that customers are supplied with world class products of the
Rawlplug Ltd. is proud to be a member of the Construction Fixings Association
highest quality and technical performance which can be independently
(CFA) which represents major fixings suppliers within the UK
certified.
and whose aims are summarised in the phrase:
use of these products. This particularly applies to the definition and the scope Technical Approval of anchors
market place can still be used during this transition period. This situation is * Downloadable free from the website which also carries articles,
complex and confusing, but during this stage customers can rely on Rawlplug news and technical advice www.fixingscfa.co.uk
Direction of Loading
The direction of the applied load must be considered to determine
the most appropriate anchor. The tension and shear components
must be less than the recommended load/design resistance in the
direction concerned.
8 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
TECHNICAL INFORMATION
Installation
Anchor choice may be affected by certain aspects of the installation,
Fig.5 for instance the desirability of a through fixing.
The fixture can then be used as a template, and the fixing made
through nominal clearance holes without the need for the object to
be removed and replaced.
Key Points
To achieve published performance values, it is essential that all
anchors are installed correctly in accordance with Rawl Fixings’
installation instructions. Some basic points to remember are:
z Drill correct diameter hole, to the correct depth.
z Clean the hole thoroughly. This is important for all anchors,
but critical for bonded anchors.
z Use the correct setting equipment and procedure.
z Tighten to the recommended torque.
Fig.6
Expanding Fixings Any reduction in the projected area, for example when anchors
Torque controlled anchors transmit expansion forces by locally are placed too close together or too near the edge of the concrete
compressing the substrate. The forces are exerted at the point (see fig.8 and fig. 9) will result in reduced performance and should
of expansion, not over the whole length of the fixing. be avoided if possible.
On applying the load to the anchor, additional forces are exerted Where unavoidable, the appropriate reduction factors shown
as shown by the light blue area ie. concrete cone (see fig.6). for reduced spacing or edge distance should be applied to the
It is this projected area which relates to the performance of the recommended load/design resistance indicated for the anchor.
anchor. Therefore as the embedment depth is increased the larger
the cone and the greater the performance of the anchor (see fig.7).
Fig.7 Fig.8
Fig.9
In previous editions of our Specification & Design Guide we quoted e Design Resistance is based upon the Characteristic Resistance
Ultimate Loads and Safe Working Loads (SWL), however, since divided by Partial Safety Factors as determined from testing.
the introduction of Ultimate Limit State theory, we have received Design Resistance should never be thought of as the load a
increasing requests to publish data in accordance with these new fixing can safely hold.
methods.
e Design Action is a factored load taking into account variable
The safety concept is based upon the Partial Safety Factor actions and should always be below the Design Resistance of
approach rather than the Global Safety Factor approach, as the anchor.
previously adopted by Rawlplug.
Those who prefer to use the Global Safety Factor method, can
Engineers familiar with the Partial Safety Factor concept can now continue to do so, using the Recommended Load (previously called
use our new Characteristic and Design Resistance figures, where: Safe Working Load).
γM
γF
10 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWL CALCULATIONS
Concrete Strength Calculation
(Loads shown are for 30N/mm2 (C20/25) concrete. For other grades
of concrete between 20 and 50N/mm2 where the anchor is in
tension the load can be calculated using this formula.)
N
rec
30N/mm Concrete
/N
2
rd
in
x √ Actual Concrete Strength
30
Global Method
(Edge and spacing reduction factors, if applicable, should be applied 1.5 1.5
to the safe tensile and shear loads.) Nact Vact ≤1.2
Nrec
+ Vrec ≤1.0
Partial Method
(Edge and spacing reduction factors, if applicable, should be applied
1.5 1.5
to the tensile and shear design resistance loads.) Nsd Vsd
Nrd + Vrd ≤1.0
Installation Depth
Glossary of abbreviations
AF = Across flats fuk = Ultimate tensile strength Nsd = Design action tension
Ccr,N = Characteristic edge distance in H = Diameter of hook S = Shield length
tension fyk = Yield strength Scr = Characteristic edge distance
Ccr,V = Characteristic edge distance in hef = Effective embedment depth in tension & shear
shear (distance from surface to point Sw = Bolt head diameter
d = Bolt thread size of expansion)
Tfix = Fixture thickness
Dcsk = Countersunk bolt head diameter hmin = Minimum substrate thickness
Tinst = Recommended torque
df = Hole diameter in fixture ho = Minimum hole depth
Vact = Applied shear load
do = Hole diameter in concrete l = Bolt length
VRk = Characteristic resistance in shear
Dw = Washer diameter lcsk = Countersunk head depth
E = Diameter of eye lg = Thread length VRd = Design resistance in shear
Fd = Design load Nact = Applied tensile load Vrec = Recommended load in shear
Frec = Recommended load Nrec = Recommended load in tension Vsd = Design action shear
FRu,m = Mean ultimate load NRd = Design resistance in tension γ = Partial safety factor for material
M
FRk = Characteristic load (95% fractile) NRk = Characteristic resistance in tension γQ = Partial safety factor for actions
THREAD
DESCRIPTION ETA PAGE
RANGE
R-CAS 46 M8-M30
R-HAC 48 M8-M30
Pending
CFS RV200 50 M8-M24
HIGH PERFORMANCE
2007
BONDED ANCHORS
R-KEX 56 M8-M30
R-KEA 58 M8-M24
R-KEM + 60 M8-M24
R-KF2/R-KSF 62 M8-M24
Insulation Fixings 68
MASONRY
12 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
PRODUCT SELECTOR
BASE MATERIAL
CONCRETE BRICKWORK BLOCKWORK
PLASTER HOLLOW
STRUCTURAL STONE LOW PLYWOOD
STANDARD SOLID PERFORATED HOLLOW BOARD DOOR
LIGHTWEIGHT DENSITY
Product Information
Sw
Dw
DESCRIPTION FEATURES
SafetyPlus™ is an all steel high performance expansion 1. 8.8 grade bolt.
anchor, suitable for the most demanding safety critical 2. High strength steel washer.
applications. This range offers exceptional tension, 3. Integral controlled collapse and anti-rotation
shear and combined load performance in concrete. feature ensures fixture is firmly secured.
4. Unique zig-zag feature provides balanced expansion
SUITABLE FOR USE IN: ensuring secure setting and maximum load carrying
Concrete capacity.
ho 5. Case-hardened nut with optimum angle taper for
maximum expansion.
90 15 50-010 SPL-08090/15
M8 13 21 14 12 80 60 120 25
110 40 50-015 SPL-08110/40
100 20 50-020 SPL-10105/20
M10 120 17 24 40 17 15 90 70 140 50 50-025 SPL-10120/40
140 60 50-030 SPL-10140/60
120 25 50-035 SPL-12120/25
M12 19 30 20 18 105 80 160 80
150 50 50-040 SPL-12150/50
145 25 50-050 SPL-16145/25
M16 24 40 26 24 125 100 200 180
170 50 50-055 SPL-16170/50
M20 175 30 50 30 30 28 155 125 240 275 50-065 SPL-20175/30
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert SafetyPlus™ anchor through 4. Tighten to the recommended
diameter and depth thoroughly clean hole. fixture into hole and tap home. torque.
through clearance hole in
the fixture into concrete.
14 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
SAFETYPLUS™ LOOSE BOLT
FOR CONCRETE
Specification Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr,V )
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the lines intersect (interpolate as required). Multiply
Distances For SafetyPlus™ Loose Bolt. tables below must be applied to the DESIGN this factor by the DESIGN RESISTANCE or
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. RECOMMENDED LOAD quoted in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found.
Where these dimensions are not achievable, Read off the reduction factor where the two
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 M20 (mm) M8 M10 M12 M16 M20 (mm) M8 M10 M12 M16 M20
70 0.72 70 60 0.70
80 0.75 0.70 80 80 0.75 0.70
90 0.78 0.73 0.70 90 100 0.80 0.74 0.65
100 0.81 0.76 0.73 100 0.55 140 0.90 0.83 0.74 0.72
120 0.87 0.82 0.78 0.72 120 0.70 0.55 180 1.00 0.91 0.82 0.78 0.70
140 0.94 0.88 0.84 0.75 0.70 140 0.85 0.70 0.55 220 1.00 0.91 0.83 0.76
160 1.00 0.94 0.89 0.79 0.73 160 1.00 0.85 0.70 260 1.00 0.89 0.82
180 1.00 0.94 0.82 0.77 180 1.00 0.85 0.55 300 0.94 0.88
200 1.00 0.86 0.80 200 1.00 0.70 0.55 340 1.00 0.94
240 0.93 0.87 240 0.85 0.70 380 1.00
280 1.00 0.93 280 1.00 0.85
320 1.00 320 1.00
Product Information
Sw
DESCRIPTION FEATURES
Dw A high performance steel expansion anchor, suitable 1. 8.8 grade stud with slot for final adjustment.
for the most demanding safety critical applications. 2. High strength steel washer.
This range offers exceptional tension, shear and com- 3. Sleeve provides maximum shear load performance.
bined load performance in concrete. 4. Integral controlled collapse and anti-rotation
feature ensures fixture is firmly secured.
SUITABLE FOR USE IN: 5. Unique zig-zag feature provides balanced expansion
Concrete ensuring secure setting and maximum load carrying
capacity.
6. Case-hardened nut with optimum angle taper for
ho
maximum expansion.
7. Nut and washer allow for fixture to be removed and
relocated easily.
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert SafetyPlus™ anchor through 4. Tighten to the recommended
diameter and depth thoroughly clean hole. fixture into hole and tap home. torque.
through clearance hole in
the fixture into concrete.
16 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
SAFETYPLUS™ BOLT PROJECTING
FOR CONCRETE
Specification Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr,V )
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the required). Multiply this factor by the DESIGN
Distances For SafetyPlus™ Bolt Projecting. tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. in the table. On the occasion that multiple
shown in the table above are the minimum Choose the required bolt diameter across the close edge and/or spacing distances occur, the
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the appropriate reduction factors must be applied.
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing
design method. distance is found. Read off the reduction factor
Where these dimensions are not achievable, where the two lines intersect (interpolate as
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 M20 (mm) M8 M10 M12 M16 M20 (mm) M8 M10 M12 M16 M20
70 0.72 70 60 0.70
80 0.75 0.70 80 80 0.75 0.70
90 0.78 0.73 0.70 90 100 0.80 0.74 0.65
100 0.81 0.76 0.73 100 0.55 140 0.90 0.83 0.74 0.72
120 0.87 0.82 0.78 0.72 120 0.70 0.55 180 1.00 0.91 0.82 0.78 0.70
140 0.94 0.88 0.84 0.75 0.70 140 0.85 0.70 0.55 220 1.00 0.91 0.83 0.76
160 1.00 0.94 0.89 0.79 0.73 160 1.00 0.85 0.70 260 1.00 0.89 0.82
180 1.00 0.94 0.82 0.77 180 1.00 0.85 0.55 300 0.94 0.88
200 1.00 0.86 0.80 200 1.00 0.70 0.55 340 1.00 0.94
240 0.93 0.87 240 0.85 0.70 380 1.00
280 1.00 0.93 280 1.00 0.85
320 1.00 320 1.00
Product Information
Sw
Dw
DESCRIPTION FEATURES
A high performance steel expansion anchor, suitable 1. 8.8 grade bolt.
for the most demanding safety critical applications. 2. High strength steel washer.
This range offers exceptional tension, shear and com- 3. Sleeve provides maximum shear load performance.
bined load performance in concrete. 4. Integral controlled collapse and anti-rotation feature
ensures fixture is firmly secured.
SUITABLE FOR USE IN: 5. Unique zig-zag feature provides balanced expansion
ho Concrete ensuring secure setting and maximum load carrying
capacity.
6. Case-hardened nut with optimum angle taper for
maximum expansion.
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert SafetyPlus™ anchor through 4. Tighten to the recommended
diameter and depth thoroughly clean hole. fixture into hole and tap home. torque.
through clearance hole in
the fixture into concrete.
18 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
SAFETYPLUS™ LIMITED EMBEDMENT
FOR CONCRETE
Specification Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr ,V)
Reduction Factors - Edge and Spacing Where these dimensions are not achievable, where the two lines intersect (interpolate as
Distances For SafetyPlus™ Limited the appropriate reduction factor/s from the required). Multiply this factor by the DESIGN
Embedment. tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found. Read off the reduction factor
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 (mm) M8 M10 M12 M16 (mm) M8 M10 M12 M16
Product Information
AF
DESCRIPTION FEATURES
Dcsk High performance countersunk all steel high 1. 8.8 grade countersunk bolt for flush fitting
performance expansion anchor for safety critical installation.
Lcsk applications where a flush fixing is required in concrete. 2. High strength steel washer.
3. Sleeve provides maximum shear load performance.
SUITABLE FOR USE IN: 4. Integral controlled collapse and anti-rotation feature
Concrete ensures fixture is firmly secured.
5. Unique zig-zag feature provides balanced expansion
ensuring secure setting and maximum load carrying
capacity.
6. Case-hardened nut with optimum angle taper for
ho maximum expansion.
SAFETYPLUS™ Countersunk
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert SafetyPlus™ anchor through 4. Tighten using hexagon driver
diameter and depth thoroughly clean hole. fixture into hole to the recommended torque.
through clearance hole in and tap home.
the fixture into concrete..
20 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
SAFETYPLUS™ COUNTERSUNK
FOR CONCRETE
Specification Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr ,V)
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the required). Multiply this factor by the DESIGN
Distances For SafetyPlus™ Countersunk. tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. in the table. On the occasion that multiple
shown in the table above are the minimum Choose the required bolt diameter across the close edge and/or spacing distances occur, the
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the appropriate reduction factors must be applied.
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing
design method. distance is found. Read off the reduction factor
Where these dimensions are not achievable, where the two lines intersect (interpolate as
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 (mm) M8 M10 M12 M16 (mm) M8 M10 M12 M16
70 0.72 70 60 0.70
80 0.75 0.70 80 80 0.75 0.70
90 0.78 0.73 0.70 90 100 0.80 0.74 0.65
100 0.81 0.76 0.73 100 0.55 140 0.90 0.83 0.74 0.72
120 0.87 0.82 0.78 0.72 120 0.70 0.55 180 1.00 0.91 0.82 0.78
140 0.94 0.88 0.84 0.75 140 0.85 0.70 0.55 220 1.00 0.91 0.83
160 1.00 0.94 0.89 0.79 160 1.00 0.85 0.70 260 1.00 0.89
180 1.00 0.94 0.82 180 1.00 0.85 0.55 300 0.94
200 1.00 0.86 200 1.00 0.70 340 1.00
240 0.93 240 0.85
280 1.00 280 1.00
Product Information
lg
DESCRIPTION FEATURES
A versatile problem-solving fixing, providing 1. Internally threaded socket for stud or rebar.
a permanent high performance threaded socket for 2. Integral controlled collapse and anti-rotation
a wide variety of studding applications, including feature ensures fixture is firmly secured.
ho deep embedment applications. 3. Unique zig-zag feature provides balanced
expansion ensuring secure setting and maximum
SUITABLE FOR USE IN: load carrying capacity.
Concrete 4. Case-hardened nut with optimum angle taper for
maximum expansion.
SOCKET ANCHOR
MAX. RECOMMENDED
HOLE DIAMETER SET FLUSH TO SURFACE SET AT DEPTH ZINC PLATED
INTERNAL TORQUE (Nm)
ANCHOR
THREAD THREAD MINIMUM EFFECTIVE MINIMUM MINIMUM EFFECTIVE MINIMUM
LENGTH IN IN
SIZE LENGTH HOLE EMBEDMENT SUBSTRATE HOLE EMBEDMENT SUBSTRATE
(mm) FIXTURE CONCRETE 4.6 STUD 8.8 STUD PRODUCT
(d) (mm) DEPTH DEPTH THICKNESS DEPTH DEPTH THICKNESS NEW CODE
(l) (mm) (mm) (Tinst ) (Tinst ) CODE
(lg ) (mm) (mm) (mm) (mm) (mm) (mm)
(df ) (do )
(df ) (hef ) (hmin ) (df ) (hef ) (hmin )
Installation
1. Screw studding into socket. 2. Ensuring nuts are securely 3. Apply fixture, washer and hexagon nut. 4. Apply torque to ensure clamping of
Assemble two nuts at the locked together, apply the fixture against concrete surface.
other end of the studding. recommended torque through
the top nut. Carefully slacken
and remove nuts.
22 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
SOCKET ANCHOR
FOR CONCRETE
Specification Data
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the required). Multiply this factor by the DESIGN
Distances for Socket Anchor. tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. in the table. On the occasion that multiple
shown in the table above are the minimum Choose the required bolt diameter across the close edge and/or spacing distances occur, the
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the appropriate reduction factors must be applied
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing
design method. distance is found. Read off the reduction factor
Where these dimensions are not achievable, where the two lines intersect (interpolate as
EDGE TENSILE: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 M20 (mm) M8 M10 M12 M16 M20
70 0.72 60 0.70
80 0.75 0.70 80 0.75 0.70
90 0.78 0.73 0.70 100 0.80 0.74 0.65
100 0.81 0.76 0.73 140 0.90 0.83 0.74 0.72
120 0.87 0.82 0.78 0.72 180 1.00 0.91 0.82 0.78 0.70
140 0.94 0.88 0.84 0.75 0.70 220 1.00 0.91 0.83 0.76
160 1.00 0.94 0.89 0.79 0.73 260 1.00 0.89 0.82
180 1.00 0.94 0.82 0.77 300 0.94 0.88
200 1.00 0.86 0.80 340 1.00 0.94
240 0.93 0.87 380 1.00
280 1.00 0.93
320 1.00
Product Information
Sw
DESCRIPTION FEATURES
The RAWL® Throughbolt range has been developed to 1. Standard and limited embedment depth markings to
Dw meet the changing demands of the market in terms ensure correct installation.
of product approval levels, ease of fixing and product 2. Cold formed body ensures constant dimensional
Standard
quality. accuracy.
embedment
The versatile through fixing for use in a wide range of 3. Stainless steel expander provides an enhanced
Reduced
embedment applications in concrete of 20N/mm2 and over. performance in cracked concrete.
Available in: Zinc plated steel. 4. Optimum cone angle for controlled expansion.
For European Approvals 5. Tested and approved by the independent UK and
see p 6/7. international approval bodies.
ho ho
SUITABLE FOR USE IN:
Cracked or Uncracked Concrete
50 14 — — — 26 5 56-314 R-HPT-08050/5
M8 65 25 — — — 33 15 56-316 R-HPT-08065/15
13 17 9 40 100 15
8 mm 80 40 55 48 15 33 30 56-320 R-HPT-08080/15
115 65 55 48 50 33 65 56-325 R-HPT-08115/50
65 22 — — — 37 5 56-328 R-HPT-10065/5
80 30 60 53 7 40 16 56-330 R-HPT-10080/7
M10
95 07 21 46 11 60 53 22 50 40 32 100 25 56-332 R-HPT-10095/22
10 mm
115 65 60 53 42 40 52 56-334 R-HPT-10115/42
130 80 60 53 57 40 67 56-336 R-HPT-10130/57
80 30 — — — 48 5 56-338 R-HPT-12080/5
100 40 80 74 4 48 24 56-340 R-HPT-12100/4
M12
120 19 24 60 13 80 74 24 60 48 44 10 60 56-342 R-HPT-12120/24
12 mm
135 75 80 74 39 48 58 56-344 R-HPT-12135/39
150 90 80 74 54 48 73 56-346 R-HPT-12150/54
105 55 — — — 65 5 56-350 R-HPT-16105/5
M16 140 60 100 89 20 67 40 56-352 R-HPT-16140/20
24 30 18 80 130 110
16 mm 180 100 100 89 60 67 80 56-354 R-HPT-16180/60
220 140 100 89 100 67 120 56-356 R-HPT-16220/100
125 65 — — — 80 5 56-360 R-HPT-20125/5
M20 160 65 120 105 20 85 40 56-362 R-HPT-20160/20
30 37 22 100 160 180
20 mm 200 100 120 105 60 85 80 56-364 R-HPT-20200/60
300 100 120 105 160 85 180 56-366 R-HPT-20300/160
Installation
1. Drill a hole of required 2. Remove debris and thoroughly 3. Lightly tap the throughbolt 4. Tighten to the recommended
diameter and depth. clean hole with brush through the fixture into hole torque.
and pump. with a hammer, until fixing
depth is reached.
24 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWL® R-HPT THROUGHBOLT
FOR CONCRETE
Specification Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr,V )
M8 11.1 16.8 5.1 9.3 4.3 7.8 9.2 9.6 4.3 5.3 3.6 4.4 80 80 100
M10 17.5 19.3 8.1 10.7 6.8 8.9 11.1 15.3 5.2 8.5 4.3 7.1 100 100 120
M12 26.3 32.2 12.2 17.9 10.2 14.9 17.2 23.3 8.0 12.9 6.7 10.8 120 120 150
M16 42.6 48.8 19.7 27.1 16.4 22.6 25.6 44.0 11.9 24.2 9.9 20.2 160 160 180
M20 60.3 75.9 27.9 42.1 23.3 35.1 47.1 65.6 21.8 36.5 18.2 30.4 190 190 260
For further explanations on calculations please see pages 10 and 11
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N ) (Scr,V )
M8 6.7 15.1 3.1 8.4 2.6 7.0 5.5 8.6 2.6 4.8 2.2 4.0 80 80 100
M10 10.9 17.6 5.0 9.7 4.2 8.1 6.9 13.9 3.2 7.7 2.7 6.4 100 100 120
M12 16.8 29.6 7.8 16.5 6.5 13.7 11.0 21.4 5.1 11.9 4.3 9.9 120 120 150
M16 28.1 45.4 13.0 25.2 10.8 21.0 16.9 40.9 7.9 22.5 6.5 18.8 160 160 180
M20 41.0 71.3 19.0 39.6 15.8 33.0 32.0 61.7 14.8 34.3 12.4 28.6 190 190 260
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the required). Multiply this factor by the DESIGN
Distances for Rawl® R-HPT. tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. in the table. On the occasion that multiple
shown in the table above are the minimum Choose the required bolt diameter across the close edge and/or spacing distances occur, the
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the appropriate reduction factors must be applied.
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing
design method. distance is found. Read off the reduction factor
Where these dimensions are not achievable, where the two lines intersect (interpolate as
40 0.60 40
50 0.73 0.62 50 0.65
60 0.87 0.65 0.74 0.60 60 0.77 0.65
80 1.00 0.83 0.65 1.00 0.80 0.67 80 0.88 0.77 0.65
100 1.00 0.83 0.65 1.00 0.84 0.62 100 1.00 0.88 0.77 0.65
120 1.00 0.77 0.65 1.00 0.74 0.58 120 1.00 0.88 0.77
140 0.88 0.77 0.87 0.73 150 1.00 0.88 0.74
160 1.00 0.88 1.00 0.82 180 1.00 0.83
190 1.00 1.00 220 0.91
260 1.00
Product Information
Sw
DESCRIPTION FEATURES
The RAWL® Throughbolt range has been developed to 1. Embedment depth markings
meet the changing demands of the market in terms to ensure correct installation.
Dw
of product approval levels, ease of fixing and product 2. Cold formed body ensures
Standard quality. constant dimensional accuracy.
embedment The versatile through fixing for use in a wide range of 3. Optimum cone angle
Reduced applications in concrete of 20N/mm2 and over. for controlled expansion.
embedment
Available in: 4. Tested and approved by
Zinc plated steel, the independent UK and
Hot dip galvanized, international approval bodies.
ho
Stainless steel grade A4.
ho For European Approvals see p. 6/7
26 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWL® R-SPT THROUGHBOLT
FOR CONCRETE
Product Information
Specification Data
RAWL® SPT Throughbolt Zinc Plated Performance Data
CONCRETE, fck,cube = 30N/mm2 (C20/25)
Installation
1. Drill a hole of required 2. Remove debris and thoroughly 3. Lightly tap the throughbolt through the 4. Tighten to the recommended
diameter and depth. clean hole with brush and pump. fixture into hole with a hammer, until torque.
fixing depth is reached.
28 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
BRASS ANCHORS
FOR CONCRETE, BRICKWORK AND STONE
Product Information
Brass Anchors
Installation
Product Information
MAXIMUM
ANCHOR HOLE HOLE
THREAD THREAD LENGTH RECOMMENDED
LENGTH DIAMETER DEPTH PRODUCT
SIZE (mm) TORQUE NEW CODE
(mm) (mm) (mm) CODE
(d) (lG ) (Nm)
(l) (do) (ho )
(Tinst )
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert wedge anchor, 4. Use the setting tool to 5. Alternatively use mechanical
diameter and depth. thoroughly clean hole with slotted end first. drive the internal wedge setting tool with appropriate
brush and pump. into the anchor. drilling machine.
30 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-DCA WEDGE ANCHOR
FOR CONCRETE & STONE
Specification Data
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE RECOMMENDED LOAD CHARACTERISTIC EDGE CHARACTERISTIC SPACING
SIZE (kN) (Factored) (kN) (Unfactored) (kN) DISTANCE (mm) * (mm)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V)
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the lines intersect (interpolate as required). Multiply
Distances for Wedge Anchor tables below must be applied to the DESIGN this factor by the DESIGN RESISTANCE or
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. RECOMMENDED LOAD quoted in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found.
Where these dimensions are not achievable, Read off the reduction factor where the two
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M6 M8 M10 M12 M16 M20 (mm) M6 M8 M10 M12 M16 M20 (mm) M6 M8 M10 M12 M16 M20
70 70 50 0.80
80 1.00 80 1.00 60 0.85 0.80
90 1.00 90 1.00 70 0.90 0.84 0.80
100 100 90 1.00 0.92 0.86 0.80
120 1.00 120 1.00 110 1.00 0.91 0.85 0.80
140 140 140 1.00 0.93 0.84 0.80
160 1.00 160 1.00 170 1.00 0.88 0.84
190 190 210 0.94 0.89
220 1.00 220 1.00 250 1.00 0.94
250 1.00 250 1.00 300 1.00
* It is recommended that Wedge anchors are not installed below the “characteristic” edge
distances quoted in the table above.
Product Information
DESCRIPTION FEATURES
The Lipped Wedge Anchor provides an easy to install 1. Internally threaded to take stud or bolt.
fixing. 2. Easy to install flush to the surface.
Allows for bolts and studs to be installed and removed 3. Ideal for setting in cavity ceilings.
without effecting the anchor.
Available in zinc plated steel.
Install with manual setting tool or mechanical setting
tool for use with hammer action drilling machines.
MAXIMUM
ANCHOR THREAD HOLE HOLE
THREAD RECOMMENDED
LENGTH LENGTH DIAMETER DEPTH PRODUCT
SIZE TORQUE NEW CODE
(mm) (mm) (mm) (mm) CODE
(d) (Nm)
(l) (lG ) (do) (ho )
(Tinst )
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert wedge anchor, 4. Use the setting tool to 5. Alternatively use mechanical
diameter and depth. thoroughly clean hole slotted end first. drive the internal wedge setting tool with appropriate
with brush and pump. into the anchor. drilling machine.
32 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-DCL LIPPED WEDGE ANCHOR
FOR CONCRETE & STONE
Specification Data
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE RECOMMENDED LOAD CHARACTERISTIC EDGE CHARACTERISTIC SPACING
SIZE (kN) (Factored) (kN) (Unfactored) (kN) DISTANCE (mm) * (mm)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V)
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the lines intersect (interpolate as required). Multiply
Distances for Lipped Wedge Anchor. tables below must be applied to the DESIGN this factor by the DESIGN RESISTANCE or
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. RECOMMENDED LOAD quoted in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found.
Where these dimensions are not achievable, Read off the reduction factor where the two
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M6 M8 M10 M12 M16 (mm) M6 M8 M10 M12 M16 (mm) M6 M8 M10 M12 M16
70 70 50 0.80
80 1.00 80 1.00 60 0.85 0.80
90 1.00 90 1.00 70 0.90 0.84 0.80
100 100 90 1.00 0.92 0.86 0.80
120 1.00 120 1.00 110 1.00 0.91 0.85 0.80
140 140 140 1.00 0.93 0.84
160 1.00 160 1.00 170 1.00 0.88
190 190 210 0.94
220 1.00 220 1.00 250 1.00
250 250 300
* It is recommended that Wedge anchors are not installed below the “characteristic” edge
distances quoted in the table above.
Product Information
Sw
Dw
DESCRIPTION FEATURES
World’s most popular expanding shield anchor. 1. Bolt lengths suitable for fixture thickness up to
Easy to use with good load carrying capacity. 150mm.
Ideal general purpose anchor bolt with excellent 2. Ferrule marked with hole
tolerance to variation in hole size. diameter for correct installation.
The collapsible ferrule ensures positive clamping 3. Pressed steel segments
ho force is transmitted to the fixture. ensure consistent
dimensional accuracy.
SUITABLE FOR USE IN: 4. Optimum taper nut angle
Concrete for maximum expansion
Brickwork in all substrates.
Stone. 5. Shield available seperately.
RAWLBOLT® Shield
34 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLBOLT® SHIELD ANCHOR LOOSE BOLT
Specification Data
RAWLBOLT® Shield Anchor Loose Bolt Performance Data
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE RECOMMENDED LOAD CHARACTERISTIC EDGE DISTANCE CHARACTERISTIC SPACING RECOMMENDED LOAD
SIZE (kN) (Factored) (kN) (Unfactored) (kN) (mm) (mm) (Unfactored) (kN)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V) (Nrec) (Vrec)
Reduction Factors - Edge and Spacing Where these dimensions are not achievable, Read off the reduction factor where the two
Distances for Rawlbolt Shield Anchor Loose the appropriate reduction factor/s from the lines intersect (interpolate as required). Multiply
Bolt tables below must be applied to the DESIGN this factor by the DESIGN RESISTANCE or
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. RECOMMENDED LOAD quoted in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found.
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M6 M8 M10 M12 M16 M20 M24 (mm) M6 M8 M10 M12 M16 M20 M24 (mm) M6 M8 M10 M12 M16 M20 M24
50 0.70 60 0.50 60 0.70
60 0.80 0.70 70 0.64 80 0.80 0.70
70 0.90 0.80 0.70 80 0.76 0.50 100 0.90 0.80 0.70
80 1.00 0.90 0.80 0.70 100 1.00 0.75 0.50 120 1.00 0.90 0.80 0.70
100 1.00 0.90 0.78 0.70 120 1.00 0.69 0.50 150 1.00 0.90 0.78 0.70
120 1.00 0.85 0.78 0.70 160 1.00 0.85 180 1.00 0.85 0.78 0.70
140 0.93 0.85 0.76 0.70 170 0.93 0.50 210 0.93 0.85 0.78 0.70
160 1.00 0.93 0.82 0.76 180 1.00 0.55 250 1.00 0.93 0.85 0.76
190 1.00 0.88 0.82 220 0.76 0.50 290 1.00 0.93 0.82
220 0.94 0.88 260 1.00 0.75 0.50 330 1.00 0.88
250 1.00 0.94 300 1.00 0.75 370 0.94
280 1.00 350 1.00 420 1.00
Brickwork Application
When installing into brickwork and there is a combined load in tension and shear,
the resultant load must not exceed the quoted performance figure.
Installation
1. Drill a hole of required 2. Remove debris and 3. Remove bolt and washer. 4. Insert bolt with washer
diameter and depth. thoroughly clean hole with Insert shield and place through the fixture and
Note: When fixing into brush and pump. fixture over the hole. tighten to the
brickwork, mortar joints recommended torque.
should be avoided.
Product Information
Sw
DESCRIPTION FEATURES
Dw World’s most popular expanding shield anchor. 1. Provides a projecting stud to support fixture
Easy to use with good load carrying capacity. during installation and removal.
Ideal general purpose anchor bolt with excellent 2. Ferrule marked with hole diameter for correct
tolerance to variation in hole size. installation.
The collapsible ferrule ensures positive clamping 3. Pressed steel segments ensure consistent
force is transmitted to the fixture. dimensional accuracy.
4. Optimum taper nut angle for maximum
ho SUITABLE FOR USE IN: expansion in all substrates.
Concrete
Brickwork
Stone.
FIXTURE RECOMMENDED
HOLE DIAMETER
NUT THICKNESS MINIMUM EFFECTIVE MINIMUM TORQUE
BOLT WASHER SHIELD (mm)
BOLT DIAMETER (mm) HOLE EMBEDMENT SUBSTRATE (Nm)
LENGTH DIAMETER LENGTH PRODUCT
REFERENCE SIZE (mm) IN IN DEPTH DEPTH THICKNESS NEW CODE
(mm) (mm) (mm) MAX. MIN. CODE
(d) (AF) FIXTURE STRUCT. (mm) (mm) (mm) 30N/mm2 20.5N/mm2
(l) (Dw) (s) (mm) (mm) CONCRETE BRICKWORK
(Sw) (mm) (mm) (ho) (hef) (hmin)
(Tfix) (Tfix) (Tinst) (Tinst)
(df) (do)
M6 10P 65 10 44-505 RBP-M06/10
M6 25P M6 80 10 12.5 45 25 0 6.5 12 50 35 70 6.5 5.0 44-510 RBP-M06/25
M6 60P 15 60 44-515 RBP-M06/60
M8 10P 75 10 44-555 RBP-M08/10
M8 25P M8 90 13 17 50 25 0 9.0 14 55 40 80 15 7.5 44-560 RBP-M08/25
M8 60P 125 60 44-565 RBP-M08/60
M10 15P 90 15 44-605 RBP-M10/15
M10 30P M10 105 17 21 60 30 0 11 16 65 50 100 27 13 44-610 RBP-M10/30
M10 60P 135 60 44-615 RBP-M10/60
M12 15P 110 15 44-655 RBP-M12/15
M12 30P M12 125 19 24 75 30 0 13 20 85 60 120 50 23 44-660 RBP-M12/30
M12 75P 170 75 44-665 RBP-M12/75
M16 15P 150 15 0 44-705 RBP-M16/15
M16 35P M16 170 24 30 115 35 10 17 25 125 95 190 120 – 44-710 RBP-M16/35
M16 75P 210 75 35 44-715 RBP-M16/75
M20 15P 170 15 0 44-755 RBP-M20/15
M20 30P M20 185 30 37 130 30 10 22 32 140 115 220 230 – 44-760 RBP-M20/30
M20 100P 255 100 30 44-765 RBP-M20/100
M24 75P 255 75 0 44-805 RBP-M24/75
M24 36 50 150 26 38 160 125 240 400 –
M24 120P 300 120 75 44-810 RBP-M24/150
Installation
1. Drill a hole of required 2. Remove debris and 3. Remove nut and washer 4. Add washer and nut and
diameter and depth. thoroughly clean hole with and insert anchor into tighten to recommended
Note: When fixing into brush and pump. hole. Position fixture over torque.
brickwork, mortar joints the thread.
should be avoided.
36 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLBOLT® SHIELD ANCHOR BOLT PROJECTING
FOR CONCRETE, BRICKWORK & STONE
Specification Data
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE RECOMMENDED LOAD CHARACTERISTIC EDGE CHARACTERISTIC SPACING RECOMMENDED LOAD
SIZE (kN) (Factored) (kN) (Unfactored) (kN) DISTANCE (mm) (mm) (Unfactored) (kN)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V) (Nrec) (Vrec)
M8 12.1 12.8 5.6 7.1 4.7 5.9 100 120 150 2.3
M10 16.7 20.9 7.7 11.6 6.4 9.7 120 160 180 2.9
M12 24.6 30.5 11.4 16.9 9.5 14.1 160 180 250 4.3
Bolts above M12
M16 57.4 55.3 26.6 30.7 22.2 25.6 190 260 290 are not recommended
in brickwork.
When calculating loads in
M20 79.4 88.1 36.8 48.9 30.7 40.8 250 300 330 brickwork, apply the published
edge distance and spacing for
concrete and assume these figures
to be the absolute minimums.
M24 99.0 122.8 45.8 68.2 38.2 56.8 280 350 420 Concrete reduction factors must
NOT be applied.
For further explanations on calculations please see pages 10 and 11
Reduction Factors - Edge and Spacing the appropriate reduction factor/s from the Multiply this factor by the DESIGN RESISTANCE
Distances for Rawlbolt Bolt Projecting tables below must be applied to the DESIGN or RECOMMENDED LOAD quoted in the table.
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. Choose On the occasion that multiple close edge and/
shown in the table above are the minimum the required bolt diameter across the top of the or spacing distances occur, the appropriate
allowable for the quoted DESIGN RESISTANCE appropriate table and read down the left hand reduction factors must be applied.
or RECOMMENDED LOAD, depending on your column until actual edge or spacing distance
design method. is found. Read off the reduction factor where
Where these dimensions are not achievable, the two lines intersect (interpolate as required).
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M6 M8 M10 M12 M16 M20 M24 (mm) M6 M8 M10 M12 M16 M20 M24 (mm) M6 M8 M10 M12 M16 M20 M24
50 0.70 60 0.50 60 0.70
60 0.80 0.70 70 0.64 80 0.80 0.70
70 0.90 0.80 0.70 80 0.76 0.50 100 0.90 0.80 0.70
80 1.00 0.90 0.80 0.70 100 1.00 0.75 0.50 120 1.00 0.90 0.80 0.70
100 1.00 0.90 0.78 0.70 120 1.00 0.69 0.50 150 1.00 0.90 0.78 0.70
120 1.00 0.85 0.78 0.70 160 1.00 0.85 180 1.00 0.85 0.78 0.70
140 0.93 0.85 0.76 0.70 170 0.93 0.50 210 0.93 0.85 0.78 0.70
160 1.00 0.93 0.82 0.76 180 1.00 0.55 250 1.00 0.93 0.85 0.76
190 1.00 0.88 0.82 220 0.76 0.50 290 1.00 0.93 0.82
220 0.94 0.88 260 1.00 0.75 0.50 330 1.00 0.88
250 1.00 0.94 300 1.00 0.75 370 0.94
280 1.00 350 1.00 420 1.00
Brickwork Application
When installing into brickwork and there is a combined load in tension and shear,
the resultant load must not exceed the quoted performance figure.
Product Information
DESCRIPTION FEATURES
Suitable for temporary or permanent anchorage. 1. Eye designed & manufactured for maximum
Supplied complete with shield, washer and hex nut. performance.
Must not be used for safety harness applications or 2. Ferrule marked with hole diameter to ensure
for lifting where shock load could be applied. correct installation.
3. Pressed steel segments ensure consistent
SUITABLE FOR USE IN: dimensional accuracy.
Concrete 4. Optimum geometry taper angle for maximum
Brickwork expansion in all substrates.
ho
Stone.
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert the Eye Bolt and 4. Tighten to recommended
diameter and depth. thoroughly clean hole with position accordingly. torque, using the nut (not
Note: When fixing into brush and pump. the eye).
brickwork, mortar joints
should be avoided.
38 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLBOLT® SHIELD ANCHOR HOOK BOLT
FOR CONCRETE, BRICKWORK & STONE
Product Information
DESCRIPTION FEATURES
Suitable for temporary or permanent anchorage. 1. Eye designed & manufactured for maximum
Supplied complete with shield, washer and hex nut. performance.
Must not be used for safety harness applications or 2. Ferrule marked with hole diameter to ensure
H for lifting where shock load could be applied. correct installation.
3. Pressed steel segments ensure consistent
SUITABLE FOR USE IN: dimensional accuracy.
Concrete 4. Optimum geometry taper angle for maximum
Brickwork expansion in all substrates.
Stone.
ho
Specification Data
RAWLBOLT® Shield Anchor Hook Bolt Performance Data
CHARACTERISTIC CHARACTERISTIC
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE RECOMMENDED LOAD
EDGE DISTANCE SPACING
SIZE (kN) (Factored) (kN) (Unfactored) (kN)
(mm) (mm)
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert the Hook Bolt and 4. Tighten to recommended
diameter and depth. thoroughly clean hole with position accordingly. torque, using the nut (not
Note: When fixing into brush and pump. the hook).
brickwork, mortar joints
should be avoided.
Product Information
Sw
DESCRIPTION FEATURES
The Rawlok® is a torque controlled expansion anchor 1. Bolt and drill size marked
comprising a split sleeve and a bolt incorporating an on sleeve to ensure correct installation.
Dw expander wedge. 2. Integral collapse feature to ensure maximum
It is a through fixing, thus allowing the hole in the clamping force is applied to the fixture.
substrate to be drilled through the pre-positioned 3. Anchor designed for optimum performance in
fixture, eliminating the need for marking out, most base material types.
ensuring fast and simple installation. 3. One piece flange nut.
Installation
1. Drill a hole of required 2. Remove debris and 3. Insert Rawlok® Sleeve 4. Tighten to recommended
diameter and depth. thoroughly clean hole with Anchor through torque with torque wrench.
Note: Fixing into mortar brush and pump. the fixture into the hole.
joints should be avoided.
40 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLOK® BOLT PROJECTING
FOR CONCRETE, BRICK, BLOCK & STONE
Specification Data
RECOMMENDED LOAD
CHARACTERISTIC LOAD DESIGN LOAD FACTORED CHARACTERISTIC EDGE DISTANCE CHARACTERISTIC SPACING
UNFACTORED
SIZE (kN) (kN) (mm) (mm)
(kN)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N) (Scr,V)
M5 2.4 3.4 1.1 1.9 0.9 1.6 1.9 3.4 0.9 1.9 0.8 1.6 1.5 2.3 0.7 1.3 0.6 1.1
M6 3.7 5.2 1.7 2.9 1.4 2.4 3.2 5.2 1.5 2.9 1.3 2.4 2.4 2.5 1.1 1.4 0.9 1.2
M8 5.0 8.6 2.3 4.8 1.9 4.0 4.5 8.6 2.1 4.8 1.8 4.0 3.5 2.7 1.6 1.5 1.3 1.3
M10 6.0 10.3 2.8 5.7 2.3 4.8 5.6 10.3 2.6 5.7 2.2 4.8 4.5 3.1 2.1 1.7 1.8 1.4
M12 7.3 13.1 3.4 7.3 2.8 6.1 6.9 13.1 3.2 7.3 2.7 6.1 5.8 3.4 2.7 1.9 2.3 1.6
For further explanations on calculations please see pages 10 and 11
When calculating loads in brickwork and blockwork apply the published edge distance and spacing for
concrete and assume these figures to be the absolute minimums. Concrete reduction factors must NOT
be applied.
Reduction Factors - Edge and Spacing Where these dimensions are not achievable, Read off the reduction factor where the two
Distances for Rawlok® Sleeve Anchor Bolt the appropriate reduction factor/s from the lines intersect (interpolate as required).
Projecting. tables below must be applied to the DESIGN Multiply this factor by the DESIGN RESISTANCE
The full characteristic edge and spacing distances RESISTANCE or RECOMMENDED LOAD. or RECOMMENDED LOAD quoted in the table.
shown in the table above are the minimum Choose the required bolt diameter across the On the occasion that multiple close edge and/
allowable for the quoted DESIGN RESISTANCE top of the appropriate table and read down the or spacing distances occur, the appropriate
or RECOMMENDED LOAD, depending on your left hand column until actual edge or spacing reduction factors must be applied.
design method. distance is found.
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M5 M6 M8 M10 M12 (mm) M5 M6 M8 M10 M12 (mm) M5 M6 M8 M10 M12
40 0.75 40 0.58 40 0.80
50 0.87 0.79 50 0.79 0.53 50 0.90 0.77
60 1.00 0.89 0.81 60 1.00 0.69 0.50 60 1.00 0.85 0.76
70 1.00 0.91 0.77 70 0.84 0.62 0.48 70 0.92 0.82 0.75
80 1.00 0.85 80 1.00 0.75 0.58 80 1.00 0.88 0.80
90 0.92 0.81 90 0.87 0.69 0.45 90 0.94 0.85 0.74
100 1.00 0.87 100 1.00 0.79 0.53 100 1.00 0.90 0.77
120 1.00 120 1.00 0.69 120 1.00 0.85
140 140 0.84 140 0.92
160 160 1.00 160 1.00
Product Information
Sw
DESCRIPTION FEATURES
Dw All purpose expansion anchor for use in medium weight 1. 5.8 grade bolt for high
applications in brickwork, blockwork and hard masonry. performance.
Through fixing, allows drilling through pre-positioned 2. Bolt and drill size marked on sleeve for accurate
fixture. installation.
No marking out required. 3. Integral collapse feature to ensure maximum
Available in yellow passivated zinc plated steel and clamping force is applied to the fixture.
stainless steel. 4. Anchor designed for optimum performance in
most base materials.
SUITABLE FOR USE IN:
Concrete
minimum ho Brickwork
Blockwork
Stone.
42 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
RAWLOK® LOOSE BOLT
FOR CONCRETE, BRICKWORK & STONE
Specification Data
RECOMMENDED LOAD
CHARACTERISTIC LOAD DESIGN LOAD FACTORED CHARACTERISTIC EDGE DISTANCE CHARACTERISTIC SPACING
UNFACTORED
SIZE (kN) (kN) (mm) (mm)
(kN)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk ) (VRk ) (NRd ) (VRd ) (Nrec ) (Vrec ) (Ccr,N ) (Ccr,V ) (Scr,N) (Scr,V)
M5 2.4 3.4 1.1 1.9 0.9 1.6 1.9 3.4 0.9 1.9 0.8 1.6 1.5 2.3 0.7 1.3 0.6 1.1
M6 3.7 5.2 1.7 2.9 1.4 2.4 3.2 5.2 1.5 2.9 1.3 2.4 2.4 2.5 1.1 1.4 0.9 1.2
M8 5.0 8.6 2.3 4.8 1.9 4.0 4.5 8.6 2.1 4.8 1.8 4.0 3.5 2.7 1.6 1.5 1.3 1.3
M10 6.0 10.3 2.8 5.7 2.3 4.8 5.6 10.3 2.6 5.7 2.2 4.8 4.5 3.1 2.1 1.7 1.8 1.4
For further explanations on calculations please see pages 10 and 11
When calculating loads in brickwork and blockwork apply the published edge distance and spacing for
concrete and assume these figures to be the absolute minimums. Concrete reduction factors must NOT
be applied.
Reduction Factors - Edge and Spacing Where these dimensions are not achievable, the Read off the reduction factor where the two
Distances for Rawlok® Loose Bolt. appropriate reduction factor/s from the tables lines intersect (interpolate as required).
The full characteristic edge and spacing distances below must be applied to the DESIGN RESISTANCE Multiply this factor by the DESIGN RESISTANCE
shown in the table above are the minimum or RECOMMENDED LOAD. Choose the required or RECOMMENDED LOAD quoted in the table.
allowable for the quoted DESIGN RESISTANCE bolt diameter across the top of the appropriate On the occasion that multiple close edge and/
or RECOMMENDED LOAD, depending on your table and read down the left hand column until or spacing distances occur, the appropriate
design method. actual edge or spacing distance is found. reduction factors must be applied.
EDGE TENSILE: EDGE REDUCTION FACTORS EDGE SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M5 M6 M8 M10 (mm) M5 M6 M8 M10 (mm) M5 M6 M8 M10
40 0.75 40 0.58 40 0.80
50 0.87 0.79 50 0.79 0.53 50 0.90 0.77
60 1.00 0.89 0.81 60 1.00 0.69 0.50 60 1.00 0.85 0.76
70 1.00 0.91 0.77 70 0.84 0.62 0.48 70 0.92 0.82 0.75
80 1.00 0.85 80 1.00 0.75 0.58 80 1.00 0.88 0.80
90 0.92 90 0.87 0.69 90 0.94 0.85
100 1.00 100 1.00 0.79 100 1.00 0.90
120 120 1.00 120 1.00
Installation
1. Drill a hole of required diameter 2. Remove debris and 3. Insert Rawlok® Sleeve 4. Tighten to recommended
and depth. thoroughly clean hole with Anchor through torque with torque wrench.
Note: When fixing into brickwork, brush and pump. the fixture into the hole.
mortar joints should be avoided.
Product Information
1
DESCRIPTION FEATURES
Fast, economical through fixing for securing timber 1. Collar holds fixture firmly in place, no screw
and metal profiles to solid brickwork and masonry. required.
No marking out or screwing required, simply 2. Spring steel anchor expands along its full length
hammers through fixture into pre-drilled hole. to provide a secure fixing.
2
SUITABLE FOR USE IN:
Concrete,
Stone,
Brickwork & Blockwork.
INSTALLATION
Installation
1. Drill hole trough fixture and 2. Insert anchor. 3. Hammer until flush to
into substrate. surface.
Clean out debris.
44 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
CONCRETE SCREWS
FOR CONCRETE, STONE, BRICKWORK & BLOCKWORK
Product Information
MATERIAL INSTALLATION TIPS
hardened steel, electro-zinc coated ~10 μm Minimum screw anchorage depth:
for dense building materials - 30 mm,
SUITABLE FOR USE IN: for aerated concrete and
Pre-drilled Ø 6mm: timber - 60 mm.
concrete,
solid and hollow brick, FEATURES
clinker brick, 1. No expansion force therefore imposes less stress
stone, on substrate during installation.
structural clay tile. 2. Small hole diameter giving high loads.
Without pre-drilling: 3. Easily removed for temporary works.
aerated concrete,
timber.
Installation
1. Pre-drilled Ø 6mm in concrete, full and hollow brick, clinker brick, stone, structural clay tile.
2. Without pre-drilling in aerated concrete, timber.
Product Information
DESCRIPTION FEATURES
R-CAS is a high performance resin anchor system 1. High performance.
for use in safety critical applications. The system 2. Quick and easy to install.
relies on the adhesion between the concrete and 3. Capsule contains exact amounts of ingredients
resin, which is free from expansion forces. This making it a very consistent product.
makes it an ideal choice where there are close edge 4. Adhesive strength is not affected by unpolluted
and spacing distances. water (curing time will be affected).
5. Suitable for overhead applications.
SUITABLE FOR USE IN: 6. Suitable for use in wet conditions.
Concrete.
M8 80 17 10 9 80 11 10 60-428 R-CAS-08
M10 80 28 12 11 90 22 10 60-430 R-CAS-10
M12 95 36 14 13 110 38 10 60-432 R-CAS-12
M16 95 42 18 17 125 95 10 60-436 R-CAS-16
M20 175 65 25 22 170 150 6 60-442 R-CAS-20
M24 210 55 28 26 210 200 6 60-446 R-CAS-24
M30 265 65 35 33 280 320 6 60-450 R-CAS-30
Boxes of M8 to M16 contain a socket driver suitable for a standard drill chuck.
Please see accessories on page 64 for additional socket drivers.
For range of internally threaded sockets see accessories page 65.
RAWL® R-CAS Studs (Also suitable for all cartridge resin systems)
BASE MATERIAL
> 20 11 – 20 6 – 10 1–5 -5 – 0
TEMPERATURE (oC)
Curing time dry 30 mins 1 hour 3 hours 6 hours 15 hours
Curing time wet 1 hour 2 hours 6 hours 12 hours 30 hours
46 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-CAS® RAWL CAPSULE
FOR CONCRETE
Specification Data
Reduction Factors – Edge and Spacing Distances. top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE or where the two lines intersect (interpolate as required). Multiply this
RECOMMENDED LOAD, depending on your design method. factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
Where these dimensions are not achievable, the appropriate reduction in the table. On the occasion that multiple close edge and/or spacing
factor/s from the tables below must be applied to the DESIGN RESISTANCE distances occur, the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
TENSILE: EDGE REDUCTION FACTORS SHEAR: EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
EDGE
(mm) (mm) M8 M10 M12 M16 M20 M24 M30
M8 M10 M12 M16 M20 M24 M30 M8 M10 M12 M16 M20 M24 M30
60 0.76 0.50 60 0.80
70 0.82 0.75 0.58 0.50 70 0.83 0.80
80 0.88 0.80 0.74 0.66 0.57 0.50 80 0.87 0.83 0.80
90 0.94 0.85 0.78 0.75 0.64 0.56 90 0.90 0.86 0.83
100 1.0 0.90 0.83 0.77 0.83 0.71 0.62 0.52 100 0.93 0.89 0.85 0.81
110 0.95 0.87 0.81 0.92 0.78 0.69 0.58 0.50 110 0.97 0.91 0.87 0.83 0.80
130 1.0 0.96 0.89 0.77 1.0 0.93 0.81 0.68 0.59 0.50 130 1.0 0.97 0.92 0.87 0.84 0.80
150 1.0 0.96 0.83 0.76 1.0 0.94 0.79 0.68 0.57 150 1.0 0.97 0.92 0.87 0.83
170 1.0 0.88 0.81 1.0 0.89 0.77 0.65 0.50 170 1.0 0.96 0.91 0.86 0.80
190 0.94 0.86 0.75 1.0 0.86 0.73 0.56 190 1.0 0.95 0.89 0.82
220 1.0 0.93 0.80 1.0 0.85 0.65 220 1.0 0.94 0.85
260 1.0 0.88 1.0 0.76 260 1.0 0.90
300 0.92 0.88 300 0.95
340 1.0 1.0 340 1.0
Installation
1. Drill correct diameter and 2. Clean the hole using brush 3. Insert R-CAS capsule into 4. Offer stud or socket up
depth of hole for the stud and air three times. the hole. Connect stud or to capsule and switch on
or socket. socket to drilling machine machine. Drive stud or 5. Position fixture and tighten
using the appropriate socket into capsule. To to recommended torque.
driver system. prevent over mixing, stop as
soon as bottom of hole is
reached. Leave undisturbed
until resin has set.
Product Information
DESCRIPTION FEATURES
R-HAC capsule range is a high performance fixing 1. High performance.
system that offers a quick and simple method of 2. Quick and easy to install.
fixing either threaded studs or rebar into solid 3. No expensive tooling required for installation.
concrete. 4. Long shelf life.
Simply installed by hammering the stud or rebar 5. Double capsules can be used for deep
through the capsule using a hammer or embedment.
mechanical drill. 6. Ideal for starter bar applications.
Not suitable for overhead applications.
Rebar
BASE MATERIAL
> 20 11 – 20 1 – 10 -5 – 0
TEMPERATURE (°C)
Curing time 1 hour 2 hours 5 hours 10 hours
Installation
48 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-HAC® RAWL CAPSULE
FOR CONCRETE
Specification Data
RAWL® R-HAC Performance Data
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V)
Reduction Factors – Edge and Spacing Distances. top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE or where the two lines intersect (interpolate as required). Multiply this factor
RECOMMENDED LOAD, depending on your design method. by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted in the table.
Where these dimensions are not achievable, the appropriate reduction On the occasion that multiple close edge and/or spacing distances occur,
factor/s from the tables below must be applied to the DESIGN RESISTANCE the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
EDGE TENSILE : EDGE REDUCTION FACTORS SHEAR : EDGE REDUCTION FACTORS SPACING TENSILE & SHEAR REDUCTION FACTORS
(mm) M8 M10 M12 M16 M20 M24 M30 M8 M10 M12 M16 M20 M24 M30 (mm) M8 M10 M12 M16 M20 M24 M30
Product Information
DESCRIPTION SUITABLE FOR USE IN:
TYPICAL APPLICATIONS RV200 is a high performance, Concrete
e Curtain walling styrene free vinylester resin Stone
e Balustrading that is suitable for use in
e Handrails concrete, and other solid
ETA PENDING 2007 e Canopies
masonry structures. This
makes it ideal for applications
e Rebar
Available from June 2007 where conventional expansion
anchors present problems.
CFS NOZZLE
QUANTITY PRODUCT CODE
4 Pack CFS-NOZ-4
24 Pack CFS-NOZ-24
Stud Data
HOLE HOLE STANDARD RECOMMENDED STUD PRODUCT CODES APPROX.
STUD STUD MAXIMUM TORQUE
WASHER DIAMETER DIAMETER EMBEDMENT No.
THREAD OVERALL FIXTURE (Nm) STAINLESS STEEL GRADE
DIAMETER IN IN IN ZINC PLATED OF HOLES
SIZE LENGTH THICKNESS (Tinst) 316 A4
(mm) CONCRETE FIXTURE CONCRETE PER 300ML
(mm) (mm) (mm)
(D w) (mm) (mm) (mm) CARTRIDGE
(d) (l) (Tfix)
(do) (df) (ho) CONCRETE NEW CODE NEW CODE
The specification of longer studs will allow We recommend that for embedment above BASE MATERIAL
TEMPERATURE WORKING TIME CURING TIME
greater fixture thicknesses than shown 500 mm and 20 mm in diameter a power (°C)
for the standard studs quoted. Minimum operated resin gun should be used. Please -5 - 0 40 mins 6 hours
embedment should be observed. contact the Rawl Technical Advisory Service 0-5 30 mins 3 hours
for further advice. 5 - 10 18 mins 2 hours
10 - 20 12 mins 1 hour 20 mins
20 - 30 6 mins 45 mins
30 - 35 3 mins 25 mins
> 35 1,5 mins 20 mins
50 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
CFS RV200 VINYLESTER STYRENE FREE RESIN
FOR CONCRETE AND STONE
Specification Data
Performance Data
CHARACTERISTIC RESISTANCE DESIGN RESISTANCE (Factored) RECOMMENDED LOAD CHARACTERISTIC EDGE CHARACTERISTIC
(kN) (kN) (Unfactored) (kN) DISTANCE SPACING
(mm) (mm)
SIZE
TENSION SHEAR TENSION SHEAR TENSION SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) TENSION & SHEAR
TENSION SHEAR (Scr)
5,8 8,8 5,8 8,8 5,8 8,8 5,8 8,8 5,8 8,8 5,8 8,8
(Ccr,N) (Ccr,V)
Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade Grade
M8 17.2 26.9 9.9 15.4 9.1 14.1 7.9 12.3 6.5 10.1 5.7 8.8 120 135 120
M10 27.6 42.6 15.7 24.1 13.1 20.3 12.6 19.3 9.4 14.5 9.0 13.8 135 165 135
M12 39.9 54.1 22.9 35.2 18.1 24.6 18.3 28.2 12.9 17.6 13.1 20.1 165 190 165
M16 74.5 74.5 42.5 65.1 32.4 32.4 34.0 52.1 23.1 23.1 24.3 37.2 190 235 190
M20 103.3 103.3 66.8 106.4 43.0 43.0 53.4 85.1 30.7 30.7 38.2 60.8 235 255 235
M20 DEEP 115.8 115.8 66.8 106.4 48.3 48.3 53.4 85.1 34.5 34.5 38.2 60.8 255 255 255
M24 128.9 128.9 95.7 152.5 51.6 51.6 76.6 122.0 36.8 36.8 54.7 87.1 280 315 280
M24 DEEP 145.8 145.8 95.7 152.5 58.3 58.3 76.6 122.0 41.6 41.6 54.7 87.1 315 315 315
M30 210.1 210.1 155.7 248.6 77.8 77.8 124.6 198.8 55.6 55.6 89.0 142.0 440 440 440
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE where the two lines intersect (interpolate as required). Multiply this
or RECOMMENDED LOAD, depending on your design method. Where factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
these dimensions are not achievable, the appropriate reduction factor/s in the table. On the occasion that multiple close edge and/or spacing
from the tables below must be applied to the DESIGN RESISTANCE or distances occur, the appropriate reduction factors must be applied.
RECOMMENDED LOAD. Choose the required bolt diameter across the
Product Information
DESCRIPTION
RM50 is a high performance, styrene SUITABLE FOR USE IN:
free resin that is suitable for use in Concrete
concrete, and other solid or hollow
masonry structures. This makes it ideal Brickwork
for applications where conventional Blockwork
expansion anchors are not appropria- Stone
te.
300 ml CFS-GUN
CFS NOZZLE
QUANTITY PRODUCT CODE
4 Pack CFS-NOZ-4
24 Pack CFS-NOZ-24
Stud Data
HOLE HOLE Standard RECOMMENDED STUD PRODUCT CODES APPROX
STUD MAXIMUM
STUD THREAD WASHER DIAMETER DIAMETER embedment TORQUE No.
OVERALL FIXTURE ZINC STAINLESS STEEL GRADE
SIZE DIAMETER IN IN IN (Nm) OF HOLES
LENGTH THICKNESS PLATED 316 A4
(mm) (mm) CONCRETE FIXTURE CONCRETE (Tinst) PER 300ML
(mm) (mm)
(d) (D w) (mm) (mm) (mm) CARTRIDGE
(l) (Tfix) PRODUCT PRODUCT
(do) (df) (ho) CONCRETE BRICKWORK NEW CODE NEW CODE
CODE CODE
M8 110 17 17 10 9 80 11 2 60-708 STUDS-08110 60-906 STUDS-08110-A4 66
M10 130 21 28 12 11 90 22 6 60-710 STUDS-10130 60-911 STUDS-10130-A4 48
M12 160 24 36 14 13 110 38 11 60-712 STUDS-12160 60-916 STUDS-12160-A4 33
M16 190 30 42 18 17 125 95 24 60-716 STUDS-16190 60-921 STUDS-16190-A4 22
M20 260 37 90 24 22 145 150 - 60-720 STUDS-20260 60-926 STUDS-20260-A4 6
M20 DEEP 260 37 55 24 22 180 150 - 60-720 STUDS-20260 60-926 STUDS-20260-A4 5
M24 295 44 85 28 26 180 200 - 60-724 STUDS-24295 60-931 STUDS-24295-A4 5
M24 DEEP 295 44 55 28 26 210 200 - 60-724 STUDS-24295 60-931 STUD-24295-A4 4
Note: For perforated brickwork and hollow block work a mesh sleeve must be inserted into the hole prior to the resin being pumped.
The specification of longer studs will allow For embedment above 500 mm and BASE MATERIAL
TEMPERATURE WORKING TIME CURING TIME
greater fixture thicknesses than shown diameters above M20 please consult the (°C)
for the standard studs quoted. Minimum Rawlplug Technical Advisory Service. 30 3 mins 25 mins
embedment should be observed. 20 7 mins 50 mins
10 22 mins 1 hour 30 mins
5 30 mins 3 hours 20 mins
Installation Solid Substrates
1. Drill hole 2. Clean 3. Insert foil into CFS 4. Insert stud or
to correct the hole gun and attach socket with a
diameter using nozzle. twisting action.
and depth brush Dispense to waste Leave the anchor
for stud size and air until an even undisturbed until
being used. three colour. the resin has
times. Then insert nozzle cured and then
and pump into attach fixture.
hole.
52 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
CFS RM50 POLYESTER STYRENE FREE RESIN
FOR CONCRETE, BRICK, BLOCK AND STONE
Specification Data
Performance Data at Standard Embedment Depth
CONCRETE, fck,cube = 30N/mm2 (C20/25) RECOMMENDED LOAD (kN) (Unfactored)
CHARACTERISTIC CHARACTERISTIC EDGE CHARACTERISTIC TENSION OR SHEAR (Frec)
DESIGN RESISTANCE RECOMMENDED LOAD SIZE
RESISTANCE DISTANCE SPACING BRICKWORK BLOCKWORK BLOCKWORK BLOCKWORK
SIZE (Factored) (kN) (Unfactored) (kN)
(kN) (mm) (mm) 20.5N/mm2 7N/mm2 3.5N/mm2 2.8N/mm2
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR M8 1.4 0.6 0.5 0.4
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V)
M10 2.9 1.3 0.9 0.7
M8 11.5 9.9 5.1 7.9 3.6 5.7 80 100 100 M12 4.0 2.0 1.1 0.9
M10 20.0 15.7 8.3 12.6 5.9 9.0 90 130 130 M16 5.0 3.0
M12 28.7 22.9 11.5 18.3 8.2 13.1 110 150 150 M20
SIZES ABOVE M12
SIZES ABOVE M16 ARE NOT RECOMMENDED
M16 45.7 42.5 16.6 34.0 11.9 24.3 130 170 170 ARE NOT RECOMMENDED
M24
M20 62.0 66.8 20.9 53.4 15.0 38.2 150 190 210
M20 DEEP 69.7 66.8 23.2 53.4 16.6 38.2 180 190 230 When calculating loads in brickwork and blockwork, apply the
M24 79.3 95.7 26.4 76.6 18.9 54.7 190 240 240 published edge distance and spacing for concrete and assume these
figures to be the absolute minimums. Concrete reduction factors must
M24 DEEP 87.9 95.7 29.3 76.6 20.9 54.7 220 240 270 NOT be applied.
For further explanations on calculations please see pages 10 and 11.
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE where the two lines intersect (interpolate as required). Multiply this
or RECOMMENDED LOAD, depending on your design method. Where factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
these dimensions are not achievable, the appropriate reduction factor/s in the table. On the occasion that multiple close edge and/or spacing
from the tables below must be applied to the DESIGN RESISTANCE or distances occur, the appropriate reduction factors must be applied.
RECOMMENDED LOAD. Choose the required bolt diameter across the
EMBEDMENT
REBAR
Concrete Strength Class: DIA. HOLE DIA.
RECOMMENDED LOAD (Frec) DEPTH TO
C20/25 (kN) FAIL REBAR
(mm)
(mm)
(25N/mm2 150mm Cylinder; 8 10 7.1 8.9 10.7 12.5
14.2 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 164
30N/mm2 150mm Cube). 10 12 9.9 11.9 13.9
15.9 17.9 19.9 21.9 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 230
Reinforcement Bar: 12 15 13.1 15.3
17.4 19.6 21.7 23.9 26.1 28.3 30.5 32.7 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 301
Minimum Yield Strength 14 18 MINIMUM 16.5
18.8 21.1 23.5 25.9 28.2 30.5 32.9 35.3 37.6 39.9 42.3 44.6 44.6 44.6 44.6 44.6 44.6 44.6 379
16 20 REBAR DEPTH 20.1 22.6 25.1 27.7 30.1 32.7 35.2 37.7 40.2 42.7 45.3 47.7 50.3 52.8 55.3 57.8 58.3 58.3 464
fyk 460N/mm2.
DEPTH (mm) 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
Note: Performance based 20 25 28.1 31.6 35.1 41.2 44.9 52.5 56.2 63.2 70.3 77.3 84.3 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 648
on clean holes; blown and 25 32 37.9 41.7 45.5 53.1 60.7 68.3 75.9 84 91 106 121 137 142 142 142 142 142 142 142 142 937
then brushed with 32 40 MINIMUM 49.7 58.1 66.3 74.7 83 91 100 116 133 149 166 182 199 216 233 233 233 233 1406
a stiff nylon brush. 40 50 REBAR DEPTH 71.5 80.5 89 98 107 125 143 161 179 197 215 232 268 304 340 364 2037
DEPTH (mm) 200 225 250 275 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1300 1500 1700 1900 2100
Product Information
DESCRIPTION SUITABLE FOR USE IN:
RP30 is general purpose Concrete
resin, for solid and hollow Brickwork
structures having a relatively Blockwork
short cure time. Stone
300 ml CFS-GUN
CFS NOZZLE
QUANTITY PRODUCT CODE
4 Pack CFS-NOZ-4
24 Pack CFS-NOZ-24
Stud Data
RECOMMENDED STUD PRODUCT CODES
HOLE STANDARD APPROX.
STUD STUD MAXIMUM HOLE TORQUE
WASHER DIAMETER EMBEDMENT No.
THREAD OVERALL FIXTURE DIAMETER (Nm) ZINC PLATED STAINLESS STEEL GRADE 316 A4
DIAMETER IN IN OF HOLES
SIZE LENGTH THICKNESS IN FIXTURE (Tinst)
(mm) CONCRETE CONCRETE PER
(mm) (mm) (mm) (mm)
(D w) (mm) (mm) PRODUCT PRODUCT 300ML
(d) (l) (Tfix) (df) CONCRETE BRICKWORK NEW CODE NEW CODE
(do) (ho) CODE CODE CARTRIDGE
BASE MATERIAL
The specification of longer studs will allow For embedment above 500 mm and WORKING CURING
TEMPERATURE
TIME TIME
(°C)
greater fixture thicknesses than shown for diameters above M20 please consult the
the standard studs quoted. Minimum Rawlplug Technical Advisory Service. 30 4 mins 30 mins
embedment should be observed. 25 7 mins 1 hour
15 15 mins 2 hours
5 30 mins 3 hours
54 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
CFS RP30 POLYESTER RESIN
FOR CONCRETE, BRICK, BLOCK AND STONE
Specification Data
Performance Data at Standard Embedment Depth
CONCRETE, fck,cube = 30N/mm2 (C20/25) RECOMMENDED LOAD (kN) (Unfactored)
TENSION OR SHEAR (Frec)
RECOMMENDED CHARACTERISTIC EDGE CHARACTERISTIC SIZE
CHARACTERISTIC DESIGN RESISTANCE
LOAD (Unfactored) DISTANCE SPACING BRICKWORK BLOCKWORK BLOCKWORK BLOCKWORK
SIZE RESISTANCE (kN) (Factored) (kN)
(kN) (mm) (mm) 20.5N/mm2 7N/mm2 3.5N/mm2 2.8N/mm2
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR M8 1.4 0.6 0.5 0.4
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V) M10 2.9 1.3 0.9 0.7
M8 9.5 9.9 4.1 7.9 2.9 5.7 60 80 80 M12 4.0 2.0 1.1 0.9
M10 16.4 15.7 6.5 12.6 4.7 9.0 70 90 90 M16 5.0 3.0
M12 25.7 22.9 9.7 18.3 6.9 13.1 80 110 110 SIZES ABOVE M12
M20 SIZES ABOVE M16 ARE NOT RECOMMENDED
M16 42.5 42.5 14.7 34.0 10.5 24.3 90 130 130 M24 ARE NOT RECOMMENDED
M20 52.0 66.8 17.6 53.4 12.6 38.2 110 150 150 When calculating loads in brickwork and blockwork, apply the
M24 61.9 95.7 20.0 76.6 14.3 54.7 130 170 170 published edge distance and spacing for concrete and assume these
figures to be the absolute minimums. Concrete reduction factors must
For further explanations on calculations please see pages 10 and 11. NOT be applied.
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE or where the two lines intersect (interpolate as required). Multiply this
RECOMMENDED LOAD, depending on your design method. factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
Where these dimensions are not achievable, the appropriate reduction in the table. On the occasion that multiple close edge and/or spacing
factor/s from the tables below must be applied to the DESIGN RESISTANCE distances occur, the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
EMBEDMENT
If you are bonding rebar into REBAR
HOLE DESIGN RESISTANCE (F d) DEPTH TO
DIA.
reinforced concrete, where (mm)
DIA. (kN) FAIL REBAR
(mm)
the size, position etc. of the
8 10 10.0 12.4 14.9 17.4 19.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 21.9 176
reinforcing is known, then 10 12 13.9 16.7 19.5 22.3 25.0 27.8 30.6 33.4 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 34.2 246
design principles contained 12 15 18.3 21.3 24.4 27.4 30.5 33.5 36.6 39.6 42.7 45.7 48.8 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 323
within Eurocode 2 can be 14 18 MINIMUM 23.0 26.3 29.6 32.9 36.2 39.5 42.8 46.1 49.4 52.7 56.0 59.2 62.5 65.8 66.9 66.9 66.9 66.9 66.9 407
16 20 REBAR DEPTH 28.1 31.7 35.2 38.7 42.2 45.7 49.3 52.8 56.3 59.8 63.3 66.9 70.4 73.9 77.4 80.9 84.4 87.4 497
adopted instead of the design DEPTH (mm) 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
recommendations contained 20 25 39.3 44.3 49.2 54.1 59.0 68.8 78.7 88.5 98.3 108 118 128 137 137 137 137 137 137 137 137 137 137 694
within this manual. 25 32 53.0 58.3 63.6 74.2 84.8 95.4 106 117 127 138 148 170 191 212 214 214 214 214 214 214 1007
32 40 MINIMUM 69.3 80.9 92.4 104 116 127 139 150 162 185 208 321 277 323 350 350 350 350 1514
40 50 REBAR DEPTH 99.3 112 124 137 149 161 174 199 224 248 298 348 397 447 497 546 2200
DEPTH (mm) 200 225 250 275 300 350 400 450 500 550 600 650 700 800 900 1000 1200 1400 1600 1800 2000 2200
EMBEDMENT
REBAR
HOLE RECOMMENDED LOAD (Frec) DEPTH TO
Concrete Strength Class: DIA.
DIA. (kN) FAIL REBAR
(mm)
C20/25 (mm)
(25N/mm2 150mm Cylinder; 8 10 6.7 8.3 9.9 11.6
13.3 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 176
30N/mm2 150mm Cube). 10 12 9.3 11.1 13.0
14.9 16.7 18.5 20.4 22.3 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 246
12 15 12.2 14.2
16.3 18.3 20.3 22.3 24.4 26.4 28.5 30.5 32.5 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 323
Reinforcement Bar: 14 18 MINIMUM 15.3
17.5 19.7 21.9 24.1 26.3 28.5 30.7 32.9 35.1 37.3 39.5 41.7 43.9 44.6 44.6 44.6 44.6 44.6 407
Minimum Yield Strength 16 20 REBAR DEPTH 18.7 21.1 23.5 25.8 28.1 30.5 32.9 35.2 37.5 39.9 42.2 44.6 46.9 49.3 51.6 53.9 56.3 58.3 497
fyk 460N/mm2. DEPTH (mm) 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
20 25 26.2 29.5 32.8 36.1 39.3 45.9 52.5 59.0 65.5 72.1 78.7 85.3 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 694
Note: Performance based
25 32 35.3 38.9 42.4 49.5 56.5 63.6 70.7 78 85 92 99 113 127 141 142 142 142 142 142 142 1007
on clean holes; blown and 32 40 MINIMUM 46.2 53.9 61.6 69.3 77 85 92 100 108 123 139 154 185 216 233 233 233 233 1514
then brushed with 40 50 REBAR DEPTH 66.2 74.5 83 91 99 108 116 132 149 166 199 232 265 298 331 364 2200
a stiff nylon brush. DEPTH (mm) 200 225 250 275 300 350 400 450 500 550 600 650 700 800 900 1000 1200 1400 1600 1800 2000 2200
Product Information
Curing Times
BASE MATERIAL TEMPERATURE (°C) WORKING TIME CURING TIME
25 12 mins 5 hours
20 25 mins 9 hours
15 75 mins 20 hours
5 120 mins 35 hours
The specification of longer studs will allow Suitable for greater than standard embedment We recommend that for embedment above
greater fixture thicknesses than shown for the for enhanced performance. 500mm and 20mm in diameter, a power
standard studs quoted. Minimum embedment operated resin gun should be used. Please
should be observed. contact the Rawl Technical Advisory Service for
further advice.
Installation
INSTALLATION
Solid substrates
1. Drill hole to correct 2. Clean the hole using brush 3. Insert cartridge into 4. Insert stud or socket with
diameter and depth for stud and air three times. cartridge gun and attach a twisting action. Leave the
size being used. nozzle. Dispense to waste anchor undisturbed until
until an even colour and the resin has cured and
then pump into hole. then attach fixture.
56 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-KEX® RAWL CARTRIDGE
FOR CONCRETE
Specification Data
Performance Data at Standard Embedment Depth
CONCRETE, fck,cube = 30N/mm2 (C20/25)
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE where the two lines intersect (interpolate as required). Multiply this fac-
or RECOMMENDED LOAD, depending on your design method. Where tor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted in the
these dimensions are not achievable, the appropriate reduction factor/s table. On the occasion that multiple close edge and/or spacing distances
from the tables (next page) must be applied to the DESIGN RESISTANCE occur, the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
Product Information
Curing Times
30 3 mins 20 mins
25 5 mins 30 mins
15 10 mins 1 hour
5 20 mins 2 hours
The specification of longer studs will allow Suitable for greater than standard embedment We recommend that for embedment above
greater fixture thicknesses than shown for the for enhanced performance. 500mm and 20mm in diameter, a power
standard studs quoted. Minimum embedment operated resin gun should be used. Please
should be observed. contact the Rawl Technical Advisory Service for
further advice.
Installation
INSTALLATION
Solid substrates
1. Drill hole to correct diameter 2. Clean the hole using brush 3. Insert cartridge into 4. Insert stud or socket with
and depth for stud size and air three times. cartridge gun and attach a twisting action. Leave the
being used. nozzle. Dispense to waste anchor undisturbed until
until an even colour and then the resin has cured and
pump into hole. then attach fixture.
58 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-KEA® RAWL CARTRIDGE
FOR CONCRETE
Specification Data
Performance Data at Standard Embedment Depth
CHARACTERISTIC RESISTANCE RECOMMENDED LOAD (Unfactored) CHARACTERISTIC EDGE DISTANCE CHARACTERISTIC SPACING
DESIGN RESISTANCE (Factored)(kN)
SIZE (kN) (kN) (mm) (mm)
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR
(NRk) (VRk) (NRd) (VRd) (Nrec) (VRec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V)
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE or where the two lines intersect (interpolate as required). Multiply this
RECOMMENDED LOAD, depending on your design method. factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
Where these dimensions are not achievable, the appropriate reduction in the table. On the occasion that multiple close edge and/or spacing
factor/s from the tables below must be applied to the DESIGN RESISTANCE distances occur, the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
Product Information
60-270 DESCRIPTION FEATURES
R-KEM-300 R-KEM+ is a high performance, styrene free system 1. Suitable for solid and hollow substrates.
(300ml) that is suitable for use in concrete, and other solid 2. Suitable for overhead applications (with care).
or hollow masonry structures. This makes it ideal for 3. R-KEM+ fits a standard mastic gun.
applications where conventional expansion anchors 4. Styrene free.
present problems. 5. Suitable for use in confined spaces
Curing Times
BASE MATERIAL TEMPERATURE (°C) WORKING TIME CURING TIME
30 3 mins 25 mins
20 7 mins 50 mins
10 22 mins 1 hour 30 mins
5 30 mins 3 hours 20 mins
The specification of longer studs will allow Note: For perforated brickwork and hollow We recommend that for embedment above
greater fixture thicknesses than shown for the block work a mesh sleeve must be inserted 500mm and 20mm in diameter a power
standard studs quoted. Minimum embedment into the hole prior to the resin being pumped. operated resin gun should be used. Please
should be observed. contact the Rawl Technical Advisory Service for
further advice.
Installation
INSTALLATION
Solid substrates
1. Drill hole to correct 2. Clean the hole using brush 3. Insert cartridge into 4. Insert stud or socket with
diameter and depth for stud and air three times. cartridge gun and attach a twisting action. Leave the
size being used. nozzle. Dispense to waste anchor undisturbed until
until an even colour and then the resin has cured and
pump into hole. then attach fixture.
INSTALLATION
Hollow substrates
& substrates with voids
1. Drill hole to correct 2. Insert sleeve into hole. 3. Insert cartridge into 4. Insert stud or socket with
diameter and depth for cartridge gun and attach a twisting action. Leave the
mesh sleeve size being used. nozzle. Dispense to waste until anchor undisturbed until
even colour. Then insert nozzle the resin has set and then
and pump to fill sleeve. attach fixture.
60 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-KEM+® RAWL CARTRIDGE
FOR CONCRETE, BRICK, BLOCK AND STONE
Specification Data
Performance Data at Standard Embedment Depth
CONCRETE, fck,cube = 30N/mm2 (C20/25) RECOMMENDED LOAD (kN) (Unfactored)
CHARACTERISTIC CHARACTERISTIC EDGE CHARACTERISTIC TENSION OR SHEAR (Frec)
DESIGN RESISTANCE RECOMMENDED LOAD SIZE
RESISTANCE DISTANCE SPACING BRICKWORK BLOCKWORK BLOCKWORK BLOCKWORK
SIZE (Factored) (kN) (Unfactored) (kN)
(kN) (mm) (mm) 20.5N/mm2 7N/mm2 3.5N/mm2 2.8N/mm2
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR M8 1.4 0.6 0.5 0.4
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V) M10 2.9 1.3 0.9 0.7
M8 11.5 9.9 5.1 7.9 3.6 5.7 80 100 100 M12 4.0 2.0 1.1 0.9
M10 20.0 15.7 8.3 12.6 5.9 9.0 90 130 130 M16 5.0 3.0
SIZES ABOVE M12
M12 28.7 22.9 11.5 18.3 8.2 13.1 110 150 150 M20 SIZES ABOVE M16 ARE NOT RECOMMENDED
M16 45.7 42.5 16.6 34.0 11.9 24.3 130 170 170 M24 ARE NOT RECOMMENDED
M20 62.0 66.8 20.9 53.4 15.0 38.2 150 190 210 When calculating loads in brickwork, apply the published edge
M20 DEEP 69.7 66.8 23.2 53.4 16.6 38.2 180 190 230 distance and spacing for concrete and assume these figures to
M24 79.3 95.7 26.4 76.6 18.9 54.7 190 240 240 be the absolute minimums. Concrete reduction factors must
M24 DEEP 87.9 95.7 29.3 76.6 20.9 54.7 220 240 270
NOT be applied.
For further explanations on calculations please see pages 10 and 11.
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE where the two lines intersect (interpolate as required). Multiply this
or RECOMMENDED LOAD, depending on your design method. Where factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
these dimensions are not achievable, the appropriate reduction factor/s in the table. On the occasion that multiple close edge and/or spacing
from the tables below must be applied to the DESIGN RESISTANCE or distances occur, the appropriate reduction factors must be applied.
RECOMMENDED LOAD. Choose the required bolt diameter across the
EMBEDMENT
Concrete Strength Class: REBAR
RECOMMENDED LOAD (Frec) DEPTH TO
DIA. HOLE DIA.
C20/25 (mm)
(kN) FAIL REBAR
(25N/mm2 150mm Cylinder; (mm)
30N/mm2 150mm Cube). 8 10 7.1 8.9 10.7 12.5
14.2 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 164
10 12 9.9 11.9 13.9
15.9 17.9 19.9 21.9 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 230
Reinforcement Bar: 12 15 13.1 15.3
17.4 19.6 21.7 23.9 26.1 28.3 30.5 32.7 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 301
Minimum Yield Strength 14 18 MINIMUM 16.5
18.8 21.1 23.5 25.9 28.2 30.5 32.9 35.3 37.6 39.9 42.3 44.6 44.6 44.6 44.6 44.6 44.6 44.6 379
fyk 460N/mm2. 16 20 REBAR DEPTH 20.1 22.6 25.1 27.7 30.1 32.7 35.2 37.7 40.2 42.7 45.3 47.7 50.3 52.8 55.3 57.8 58.3 58.3 464
DEPTH (mm) 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
Note: Performance based 20 25 28.1 31.6 35.1 41.2 44.9 52.5 56.2 63.2 70.3 77.3 84.3 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 648
on clean holes; blown and 25 32 37.9 41.7 45.5 53.1 60.7 68.3 75.9 84 91 106 121 137 142 142 142 142 142 142 142 142 937
then brushed with 32 40 MINIMUM 49.7 58.1 66.3 74.7 83 91 100 116 133 149 166 182 199 216 233 233 233 233 1406
a stiff nylon brush. 40 50 REBAR DEPTH 71.5 80.5 89 98 107 125 143 161 179 197 215 232 268 304 340 364 2037
DEPTH (mm) 200 225 250 275 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1300 1500 1700 1900 2100
Product Information
60-200 DESCRIPTION FEATURES
R-KF2-380 R-KF2 and R-KSF are 1. Suitable for Solid and Hollow
(380ml) general purpose resins, for solid substrates.
and hollow structures with both 2. 150ml R-KSF is ideal for small
products having a relatively short applications.
cure time. 3. R-KSF fits a standard
mastic gun.
SUITABLE FOR USE IN: 4. R-KSF Odourless and
Concrete Styrene free.
60-150 Brickwork
R-KSF-150 Blockwork
(150ml) Stone
Overhead Applications
R-KF2 R-KSF
BASE MATERIAL BASE MATERIAL
WORKING CURING WORKING
TEMPERATURE TEMPERATURE CURING TIME
TIME TIME TIME
(°C) (°C)
30 4 mins 30 mins 30 4 mins 30 mins
25 7 mins 1 hour 20 8 mins 50 mins
15 15 mins 2 hours 15 14 mins 2 hours
5 30 mins 3 hours 5 30 mins 4 hours
The specification of longer studs will allow We recommend that embedment above Please contact the Rawl Technical Advisory
greater fixture thicknesses than shown for the 500mm and 20mm in diameter a power Service for further advice.
standard studs quoted. Minimum embedment operated resin gun should be used.
should be observed.
Installation
INSTALLATION
Solid substrates
1. Drill hole to correct 2. Clean the hole using brush 3. Insert cartridge into 4. Insert stud or socket with
diameter and depth for stud and air three times. cartridge gun and attach a twisting action. Leave the
size being used. nozzle. Dispense to waste anchor undisturbed until the
until an even colour and then resin has cured and then
pump into hole. attach fixture.
INSTALLATION
Hollow substrates &
substrates with voids
1. Drill hole to correct 2. Insert sleeve into hole. 3. Insert cartridge into 4. Insert stud or socket with
diameter and depth for cartridge gun and attach a twisting action. Leave the
mesh sleeve size being used. nozzle. Dispense to waste until anchor undisturbed until
even colour. Then insert nozzle the resin has set and then
and pump to fill sleeve. attach fixture.
62 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
R-KF2/KSF® RAWL CARTRIDGE
FOR CONCRETE, BRICK, BLOCK AND STONE
Specification Data
Performance Data at Standard Embedment Depth
CONCRETE, fck,cube = 30N/mm2 (C20/25) RECOMMENDED LOAD (kN) (Unfactored)
TENSION OR SHEAR (Frec)
RECOMMENDED CHARACTERISTIC EDGE CHARACTERISTIC SIZE
CHARACTERISTIC DESIGN RESISTANCE
LOAD (Unfactored) DISTANCE SPACING BRICKWORK BLOCKWORK BLOCKWORK BLOCKWORK
SIZE RESISTANCE (kN) (Factored) (kN)
(kN) (mm) (mm) 20.5N/mm2 7N/mm2 3.5N/mm2 2.8N/mm2
TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION SHEAR TENSION & SHEAR M8 1.4 0.6 0.5 0.4
(NRk) (VRk) (NRd) (VRd) (Nrec) (Vrec) (Ccr,N) (Ccr,V) (Scr,N) (Scr,V) M10 2.9 1.3 0.9 0.7
M8 9.5 9.9 4.1 7.9 2.9 5.7 60 80 80 M12 4.0 2.0 1.1 0.9
M10 16.4 15.7 6.5 12.6 4.7 9.0 70 90 90 M16 5.0 3.0
M12 25.7 22.9 9.7 18.3 6.9 13.1 80 110 110 SIZES ABOVE M12
M20 SIZES ABOVE M16 ARE NOT RECOMMENDED
M16 42.5 42.5 14.7 34.0 10.5 24.3 90 130 130 M24 ARE NOT RECOMMENDED
M20 52.0 66.8 17.6 53.4 12.6 38.2 110 150 150 When calculating loads in brickwork, apply the published edge
M24 61.9 95.7 20.0 76.6 14.3 54.7 130 170 170 distance and spacing for concrete and assume these figures to
For further explanations on calculations please see pages 10 and 11. be the absolute minimums. Concrete reduction factors must
NOT be applied.
Reduction Factors – Edge and Spacing Distances top of the appropriate table and read down the left hand column until
The full characteristic edge and spacing distances shown in the table actual edge or spacing distance is found. Read off the reduction factor
above are the minimum allowable for the quoted DESIGN RESISTANCE or where the two lines intersect (interpolate as required). Multiply this
RECOMMENDED LOAD, depending on your design method. factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted
Where these dimensions are not achievable, the appropriate reduction in the table. On the occasion that multiple close edge and/or spacing
factor/s from the tables below must be applied to the DESIGN RESISTANCE distances occur, the appropriate reduction factors must be applied.
or RECOMMENDED LOAD. Choose the required bolt diameter across the
EMBEDMENT
REBAR
HOLE RECOMMENDED LOAD (Frec) DEPTH TO
DIA.
Concrete Strength Class: DIA. (kN) FAIL REBAR
(mm)
(mm)
C20/25
8 10 6.7 8.3 9.9 11.6
13.3 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6 176
(25N/mm2 150mm Cylinder; 10 12 9.3 11.1 13.0
14.9 16.7 18.5 20.4 22.3 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 22.8 246
30N/mm2 150mm Cube). 12 15 12.2 14.2
16.3 18.3 20.3 22.3 24.4 26.4 28.5 30.5 32.5 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 32.8 323
Reinforcement Bar: 14 18 MINIMUM 15.3
17.5 19.7 21.9 24.1 26.3 28.5 30.7 32.9 35.1 37.3 39.5 41.7 43.9 44.6 44.6 44.6 44.6 44.6 407
16 20 REBAR DEPTH 18.7 21.1 23.5 25.8 28.1 30.5 32.9 35.2 37.5 39.9 42.2 44.6 46.9 49.3 51.6 53.9 56.3 58.3 497
Minimum Yield Strength
DEPTH (mm) 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
fyk 460N/mm2.
20 25 26.2 29.5 32.8 36.1 39.3 45.9 52.5 59.0 65.5 72.1 78.7 85.3 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 91.1 694
Note: Performance based 25 32 35.3 38.9 42.4 49.5 56.5 63.6 70.7 78 85 92 99 113 127 141 142 142 142 142 142 142 1007
on clean holes; blown and 32 40 MINIMUM 46.2 53.9 61.6 69.3 77 85 92 100 108 123 139 154 185 216 233 233 233 233 1514
then brushed with 40 50 REBAR DEPTH 66.2 74.5 83 91 99 108 116 132 149 166 199 232 265 298 331 364 2200
a stiff nylon brush. DEPTH (mm) 200 225 250 275 300 350 400 450 500 550 600 650 700 800 900 1000 1200 1400 1600 1800 2000 2200
Product Information
60-687 60-980 Brushes and Blow Pump
HOLE SIZE BRUSHES PACK QUANTITY PRODUCT CODE NEW CODE
Dispenser Guns
DESCRIPTION SUITABLE FOR PACK TYPE QUANTITY PRODUCT CODE NEW CODE
400ml CARTRIDGE GUN R-KEX POLYBAG 1 60-645 R-GUN-400ml
380ml CARTRIDGE GUN R-KF2 / R-KEA POLYBAG 1 60-660 R-GUN-380ml
300ml SKELETON GUN R-KSF / R-KEM POLYBAG 1 60-160 R-GUN-300ml
CFS Gun 300ml CARTRIDGE GUN R-KEM+ POLYBAG 1 60-172 R-GUN-300ml-C
300ml CFS GUN CFS BOXED 1 - CFS GUN
BOX PRODUCT
DESCRIPTION NEW CODE
QUANTITY CODE
MIXER NOZZLE (R-KF2, R-KSF, R-KEA) 10 60-640 NOZ-10
MIXER NOZZLE (R-KF2, R-KSF, R-KEA) 100 60-642 NOZ-100
DESCRIPTION DRILLING MACHINE PRODUCT CODE NEW CODE MIXER NOZZLE (R-KEX) 10 60-228 NOZ-RKEX-10
ADAPTOR SDS Plus 60-780 SDS-ADAPTOR MIXER NOZZLE (CFS) 4 - CFS-NOZ-4
SETTING HEAD SDS Plus 60-782 SDS-SETTING MIXER NOZZLE (CFS) 12 - CFS-NOZ-12
64 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
BONDED ANCHOR ACCESSORIES
INTERNALLY THREADED SOCKETS
Product Information
Internally Threaded Sockets
SOCKET HOLE HOLE SOCKET PRODUCT CODES
SOCKET HOLE
TYPE AND DIAMETER DIAMETER TIGHTENING TORQUE (Nm) ZINC STAINLESS STEEL GRADE
OVERALL DEPTH IN USE WITH SOCKETS DRIVE SYSTEM
INTERNAL IN IN PLATED 303 A2
LENGTH CONCRETE CAPSULE PER BOX/
THREAD CONCRETE FIXTURE
(mm) (mm) Ref 2 2
30 N/mm 20.5 N/mm 7.0 N/mm 2 PACK RODUCT PRODUCT PRODUCT
LENGTH (mm) (mm) NEW CODE NEW CODE NEW CODE
(l) (ho) CONCRETE BRICKWORK BLOCKWORK CODE CODE CODE
(lg) (do) (df)
M6x24 75 12 75 7 R-CAS-10 5 3 1.5 10 60-620 ITS-Z-06075 — — 60-690 ITS-DRIVE-06
M6x24 75 14 75 7 R-CAS-10 5 3 1.5 10 — — 60-985 ITS-SS-06075 60-690 ITS-DRIVE-06
M8x25 75 14 75 9 – 11 6 3 10 60-622 ITS-Z-08075 60-987 ITS-SS-08075 — —
M8x25 90 14 90 9 R-CAS-12 11 6 3 10 60-623 ITS-Z-08090 60-988 ITS-SS-08090 60-692 ITS-DRIVE-08
M10x30 75 20 75 11 – 22 13 6 10 60-624 ITS-Z-10075 60-989 ITS-SS-10075 — —
M10x30 100 20 100 11 R-CAS-16 22 13 3 10 60-626 ITS-Z-10100 60-992 ITS-SS-10100 60-694 ITS-DRIVE-10
M12x35 100 20 100 13 R-CAS-16 38 21 6 6 60-628 ITS-Z-12100 — — 60-696 ITS-DRIVE-12
M12x35 100 22 100 13 R-CAS-16 38 21 6 6 — — 60-993 ITS-SS-12100 60-696 ITS-DRIVE-12
M16x50 125 28 125 17 R-CAS-20 95 30 – 6 60-630 ITS-Z-16125 60-995 ITS-SS-16125 60-698 ITS-DRIVE-16
All sockets can be used with cartridge systems and in these circumstances a drive system is not required.
lg
Plastic Sleeves
HOLE DIAMETER
STUD SIZE SLEEVE LENGTH BOX
IN STRUCTURE PRODUCT CODE NEW CODE
(mm) (mm) QUANTITY
(mm)
M6/M8 16 13 x 80 10 60-607 PLS-13080-10
M6/M8 16 13 x 80 5 60-608 PLS-13080-5/5
M10 16 13 x 130 10 60-609 PLS-13130-10
M10 16 13 x 130 5 60-614 PLS-13130-5/5
M12/M16 20 18 x 85 10 60-615 PLS-18085-10
M12/M16 20 18 x 85 5 60-616 PLS-18085-5/5
Mesh Sleeves
HOLE DIAMETER
STUD SIZE SLEEVE LENGTH BOX
IN STRUCTURE PRODUCT CODE NEW CODE
(mm) (mm) QUANTITY
(mm)
M6/M8 12 11 x 85 10 60-805 MS-11085
M10 16 15 x 95 10 60-807 MS-15095
M10 16 15 x 130 10 60-809 MS-15130
M10 16 15 x 200 10 60-111 MS-15200
M12 18 17 x 95 10 60-113 MS-17095
M12 18 17 x 200 10 60-115 MS-17200
M16 22 21 x 200 10 60-117 MS-21200
Mesh Sleeves x 1m
THREADED RODS
MATERIAL
Grade 4.8, Length 1m
steel DIN 975 - zinc plated.
THREAD QUANTITY PRODUCT CODE
M6 50 975-06-1000-ZN
M8 50 975-08-1000-ZN
M10 25 975-10-1000-ZN
M12 20 975-12-1000-ZN
M16 10 975-16-1000-ZN
M20 10 975-20-1000-ZN
M6 10 975-06-1000-88-ZN
M8 5 975-08-1000-88-ZN
M10 5 975-10-1000-88-ZN
M12 5 975-12-1000-88-ZN
M16 5 975-16-1000-88-ZN
M20 5 975-20-1000-88-ZN
66 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
NUTS & WASHERS
Product Information
COUPLING NUT
MATERIAL QUANTITY
DESCRIPTION PRODUCT CODE
Low carbon steel, electro zinc plated. BOX OUTER
Product Information
Installation
Product Information
Installation
68 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
INSULATION FIXINGS
FOR CONCRETE, MASONRY, BLOCKWORK, STONE.
Product Information
10MM INSULATION FIXINGS WITH HAMMER-IN NYLON PIN
Installation
INSULATION
PLUG HOLE DIAMETER QUANTITY
THICKNESS PRODUCT CODE
DESCRIPTION (mm) PACK
(mm)
35 x 70 8 30-40 400 KIK-070
35 x 90 8 50-60 400 KIK-090
Product Information
METAL FIRE RESISTANT INSULATION SUPPORT
Installation
PLUG LENGTH HOLE DIAMETER QUANTITY
PRODUCT CODE
(mm) (mm) PACK
90 8 250 MKI-090/8
110 8 250 MKI-110/8
140 8 250 MKI-140/8
170 8 250 MKI-170/8
200 8 250 MKI-200/8
Product Information
INSULATION FLANGE WITH COVER CAP
MATERIAL INSTALLATION TIPS
TYPICAL APPLICATIONS
Impact resistant co-polymer e Anchorage depth: min. 30 mm
e For fixing both light polystyrene
of polypropylene PP
and heavy mineral wool boards in
or polyamide PA 6.0 (Nylon)
combination with appropriate screws to
to order.
facade walls made from: timber, sheet
metal, plasterboard, etc.
Installation
FLANGE
QUANTITY
DIAMETER PRODUCT CODE
PACK
(mm)
60 200 KC
Product Information
DESCRIPTION FEATURES
Developed for SDS rotary hammer 1. Twin spiral shank for fast,
drilling machines. effective, clearance of spoil.
Provides faster, easier drilling with 2. Specially designed tip
lower power consumption. outperforms other brands for
performance and longevity.
3. Can be extended with
SDS extension sleeves in
conjunction with impactor
drill range marked.
SDS
DIAMETER LENGTH DIAMETER LENGTH
PRODUCT CODE NEW CODE PRODUCT CODE NEW CODE
(mm) (mm) (mm) (mm)
4.0 110 34-006 SDS-40110 14.0 150 34-128 SDS-14150
5.0 110 34-010 SDS-50110 14.0 200 34-230 SDS-14200
5.0 160 34-110 SDS-50160 14.0 250 34-328 SDS-14250
5.5 110 34-011 SDS-55110 14.0 300 34-388 SDS-14300
5.5 160 34-111 SDS-55160 14.0 450 34-428 SDS-14450
6.0 110 34-012 SDS-60110 15.0 150 34-130 SDS-15150
6.0 160 34-112 SDS-60160 15.0 250 34-330 SDS-15250
6.0 210 34-210 SDS-60210 16.0 150 34-132 SDS-16150
6.5 110 34-013 SDS-65110 16.0 200 34-232 SDS-16200
6.5 160 34-113 SDS-65160 16.0 300 34-390 SDS-16300
6.5 210 34-212 SDS-65210 16.0 450 34-432 SDS-16450
7.0 110 34-014 SDS-70110 16.0 600 34-532 SDS-16600
7.0 160 34-114 SDS-70160 16.0 800 34-538 SDS-16800
7.0 210 34-214 SDS-70210 18.0 200 34-236 SDS-18200
8.0 110 34-016 SDS-80110 18.0 300 34-392 SDS-18300
8.0 160 34-116 SDS-80160 18.0 450 34-436 SDS-18450
8.0 210 34-216 SDS-80210 18.0 600 34-536 SDS-18600
8.0 260 34-318 SDS-80260 18.0 1000 34-592 SDS-181000
9.0 210 34-218 SDS-90210 20.0 200 34-240 SDS-20200
10.0 110 34-020 SDS-100110 20.0 450 34-440 SDS-20450
10.0 160 34-120 SDS-10160 20.0 600 34-540 SDS-20600
10.0 260 34-320 SDS-10260 20.0 1000 34-594 SDS-201000
10.0 310 34-380 SDS-10310 22.0 250 34-344 SDS-22250
10.0 450 34-420 SDS-10450 22.0 450 34-442 SDS-22450
10.0 600 34-520 SDS-10600 22.0 1000 34-596 SDS-221000
11.0 310 34-382 SDS-11310 24.0 250 34-348 SDS-24250
12.0 160 34-124 SDS-12160 24.0 450 34-448 SDS-24450
12.0 250 34-324 SDS-12250 25.0 250 34-350 SDS-25260
12.0 300 34-384 SDS-12300 25.0 450 34-450 SDS-25450
12.0 450 34-424 SDS-12450 25.0 600 34-550 SDS-25600
12.0 1000 34-586 SDS-121000 26.0 450 34-452 SDS-26450
13.0 150 34-126 SDS-13150
13.0 250 34-326 SDS-13250
13.0 450 34-426 SDS-13450
70 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
IMPACTOR ®
FOR CONCRETE, BRICKWORK & HARD MASONRY
Product Information
DESCRIPTION FEATURES
Masonry bit for mains and cordless 1. High grade alloy tool steel and
drilling machines. furnace hardened to SDS
Drills more holes per battery charge standards, making bits stronger,
than other masonry bits. more durable and safer to use.
Sizes and lengths of up to 400 mm. 2. Geometrically designed flute
Extension bars available for deeper maximises spoil evacuation.
drilling. 3. Copper brazed carbide tip,
Packed in re-sealable tubes. strengthens the bond between
tip & body.
IMPACTOR®
DIAMETER LENGTH
QUANTITY PRODUCT CODE NEW CODE
(mm) (mm)
4.5 85 1x10 32-009 IMP-45085-10W
5.0 100 1x10 32-010 IMP-50100-10W
5.0 150 1 32-110 IMP-50150-W1
5.5 100 1x10 32-011 IMP-55100-10W
5.5 150 1 32-111 IMP-55150-W1
6.0 100 1x10 32-012 IMP-60100-10W
6.0 150 1 32-112 IMP-60150-W1
6.5 100 1x10 32-013 IMP-65100-10W
6.5 150 1 32-113 IMP-65150-W1
7.0 100 1x10 32-014 IMP-70100-10W
7.0 150 1 32-114 IMP-70150-W1
7.0 300 1 32-314 IMP-70300-W1
8.0 120 1x10 32-016 IMP-80120-10W
8.0 150 1 32-116 IMP-80150-W1
8.0 200 1 32-216 IMP-80200-W1
8.0 300 1 32-316 IMP-80300-W1
10.0 120 1x10 32-020 IMP-10120-10W
10.0 150 1 32-120 IMP-10150-W1
10.0 200 1 32-220 IMP-10200-W1
10.0 300 1 32-320 IMP-10300-W1
10.0 400 1 32-420 IMP-10400-W1
12.0 150 1 32-124 IMP-12150-W1
12.0 200 1 32-224 IMP-12200-W1
12.0 300 1 32-324 IMP-12300-W1
12.0 400 1 32-424 IMP-12400-W1
13.0 150 1 32-126 IMP-13150-W1
13.0 400 1 32-426 IMP-13400-W1
14.0 150 1 32-128 IMP-14150-W1
u 14.0 300 1 32-328 IMP-14300-W1
14.0 400 1 32-428 IMP-14400-W1
15.0 150 1 32-130 IMP-15150-W1
16.0 150 1 32-132 IMP-16150-W1
u 16.0 300 1 32-332 IMP-16300-W1
16.0 400 1 32-432 IMP-16400-W1
18.0 160 1 32-136 IMP-18160-W1
18.0 400 1 32-436 IMP-18400-W1
19.0 160 1 32-138 IMP-19160-W1
20.0 160 1 32-140 IMP-20160-W1
u 20.0 300 1 32-340 IMP-20300-W1
Extension Sleeve 20.0 400 1 32-440 IMP-20400-W1
22.0 160 1 32-144 IMP-22160-W1
PRODUCT EFFECTIVE LENGTH PRODUCT NEW u 22.0 300 1 32-344 IMP-22300-W1
QANTITY
DESCRIPTION (mm) CODE CODE
25.0 160 1 32-150 IMP-25160-W1
u 14-16 mm 250 1 83-032 EXS-1416 u 25.0 300 1 32-350 IMP-25300-W1
u 20-25 mm 250 1 83-050 EXS-2025 25.0 400 1 32-450 IMP-25400-W1
Product Information
DESCRIPTION FEATURES
All-purpose masonry drill bit for 1. Brass brazed tungsten carbide
rotary percussive drilling machines. tip, for high drilling speeds.
Blue Flash™
DIAMETER LENGTH
QUANTITY PRODUCT CODE NEW CODE
(mm) (mm)
72 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
NOTES
74 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
The Technical Department offers a variety of
services to specifiers, distributors and users of
Rawl Fixings products.
Technical Advice
Fixing specialists will offer immediate advice and
recommendations over the telephone.
Field Engineers
Are available to offer fixing advice at your office or on site.
Site Testing
Rawl Fixings engineers will conduct site testing to ensure
the appropriate fixing is specified and used. A detailed
report is provided with recommendations.
Contractor Training To ensure that we continue to meet the future requirements of the industry, Rawlplug
Rawl Fixings engineers will be pleased to carry out practical has a policy of continuous product development supported by extensive design and
training for contractors to ensure anchors are installed
correctly. test centre facilities. Rawlplug therefore reserves the right to modify product designs
without prior notice. Rawlplug also reserves the right to modify information contained
Technical Calculation Software within this guide without notifying existing holders of the document. While this
l An innovative calculation CD ROM from Rawl Fixings. document gives guidance relating to the use and nature of the products and
l Allows calculations and product selections to be made
variety of applications, the ultimate responsibility for correct selection of a product for
in concrete.
l Includes both mechanical and chemical anchor a specific application must lie with the customer. Rawlplug recommendations are
made in good faith but do not constitute a guarantee.
solutions.
l For your free CD, please e-mail Rawl Fixings
at technical@rawlplug.co.uk
2 Technical Advisory Service Tel: +44 (0) 1530 812 857, Fax: +44 (0) 1530 812 862
Cl/SfB Xt6
August 2007