SURPLUS EQUIPMENT CATALOGUE
8-10 TONNE GOLD ROOM AND REFINERY
The Company
Apex Minerals is a mining company based in Malaysia with operating mineral properties in the
Phillipines and other exploration/development prospects in various areas of the world
It was incorporated in 1970 and its purpose is to acquire, develop and operate mines in various
areas of the world. Current operations include an operating gold mine located in the Phillipines
on the island of Mindanao about 115 kilometres by road from the port city of Daveo.
This equipment was purchased in 2007/2008 for the purposes of carrying out a significant
expansion at the Masara Mine planned by Crew Minerals, the then owners of Apex Mining.
Soon after the equipment had been delivered, the project was put on hold by new management
at Apex while further studies and evaluation were carried out. In the meantime the equipment
was securely stored for future use in a secure warehouse in Jade valley where it has remained
ever since.
In 2009 Crew Minerals sold Apex Mining to a Malaysian company who after completing further
review have decided to approach the expansion of the plant on a more gradual basis and
consider the equipment to be surplus to their needs.
The equipment available consists of all the major items required for a state-of-the-art gold room
with the capability of processing 8-10 tonnes of activated carbon per day.
Summary Description
The process is designed with a Split Zadra elution system, basketless cathode electrowinning
cells, an electrically heated horizontal carbon regeneration kiln, induction smelting furnace and
all the supporting equipment required for a complete gold room including structural steel,
platforms, stairways, guard rails etc required for the plant. Much of the equipment still remains
in its original shipping crates and packaging and is in very good condition.
It has been recently inspected and a detailed list prepared. Brief notes are included in the
Detailed Inspection list below of the findings of that inspection for each piece of equipment.
It is Apex’s intention to offer all of the equipment for sale as a package. It will suit anyone who
requires a complete gold room package. The equipment is all of good quality privided by
reputable suppliers to the industry and will give sterling service. Engineering drawings including
general arrangement, P&ID’s will be made available on request Installation and Operating
manuals, steel erection drawings electrical and structural steel drawings are extant and will be
available from the manufacturers to buyers to support their subsequent design and construction
activities. We are sure it will meet any technical requirements for such a plant It is available
for inspection any time with suitable notice and would be made available to the buyer
immediately upon settlement.
For further information please direct any queries to:
Frank Metcalfe
Surplus Equipment Sales Representative
APEX Mining Company Ltd
MMM Services P/L
Lvl 4 15-17 Young Street
Sydney, NSW, 2000
Australia
Ph: +61 2 9252-7910
Fax: +61 2 9975-7839
Mobile: (+61) 0417 678 071
SECTION 2
REPRESENTATIVE
PICTURES
Carbon Strip Elution Boilers and heat exchangers on skid in Warehouse
Electrowinning cell on support frame with piping and crated goods
Structural steel and railing stored in warehouse
Structural steel with dust collector and acid tanks in background, stored in yard
Grating and structural steel stored in warehouse with E/W sludge filter in background
General view of storage items in warehouse
Carbon storage tanks and structural steel
Packaged Duct Materials on pallet in Warehouse
Agitator Tank in warehouse
General stored items in warehouse including sump pump, stairway and mold rack for gold
pour
Agitator drive units for carbon tanks
General pallet and crated items stored in warehouse
Carbon Regeneration Kiln Feed Hopper stored in yard
Carbon Kiln on Factory floor ready to ship
Feed end of kiln showing drive and sealing systems
Kiln covered and stored in warehouse yard
Agitated carbon storage tank
Electrowinning Sludging Cells (2)
Elution Columns (2) with Acid Wash Column
Elution Columns and Acid wash with Bullion Furnace Dust Collector on right
Sump Pump and other boxed equipment inside warehouse
Acid Wash Fan, mould trolley and other equipment stored in warehouse
Crated equipment stored in warehouse
Structural Steel stored in yard with acid tanks and dust collector in background left
Structural steel and railings stored in Warehouse with E/W cell in the background
Carbon storage tanks in the yard outside of the warehouse
Platform grating sections with the E/W sludge filter in background
Dust Collector internal parts
For Independent Sale
Other Non Gold Room
Surplus Items
Thermoscientific Weigh Belt Feeder (not part of Gold room)
Overhead crane at mine (not part of the gold room)
Seven (7) KEMIX Intertank CIL/ CIP Screens Model AAC MPS-
EQUIPMENT LIST
AND
INSPECTION REPORT
Equipment list and Inspection Report
SVEE No of
ITEM NAME DESCRIPTION COMMENTS
Equipment ID units
Carbon Fines Plate Seimens J‐Press Model Very good condition essentially as
FL801 1
and Frame Filter 800G32‐29‐15DYLW new. No rust or corrosion
Electrowinning
Siemens J‐Press Model Very good condition essentially as
FL701 SludgePlate and 1
630p32‐15‐4MYLW new No rust or corrosion
Frame Filter
Boilers and heat Very good as new condition.
800 kW Solution
HS601 exchangers for elution 1 Opened and inspected control
Heater Skid
circuit panels etc Pristine
Activated Carbon Wemco Torque flow
PC801 1 As new No damage or corrosion
Transfer Pump pump and motor
Stripped Carbon Wemco Torque flow
PC802 1 As new No damage or corrosion
Attrition Pump pump and motor
PC401 Carbon Pump Acid Wash 1 As new No damage or corrosion
PC501 Carbon pump Stripped Carbon pump 1 As new
Acid Area Sump Model SG‐PY800HA 16
PS401 1 As New Very good condition
Pump cu m /hr
CPVC Schedule 80
Piping 20 ft lengths 1 lot As new
various sizes
HCl mixer/pump?
PP402 TEFC 1 Boxed
motor
Concentrated HCl
PP402 MDL PFP‐40 1 Boxed
Barrel Pump
Flux Mixer Small cement mixer Sold
Still in box. Never unpacked No
evidence of any damage. Controls
etc likewise still crated/boxed but
Bullion Induction ISOTHERM Induction
MF701‐1 1 only inspected for shipping
Furnace Furnace Package
damage. None discovered.
Equipment should be essentially
as new.
SE Equipment No of
ITEM NAME DESCRIPTION COMMENTS
ID units
Still in crate. Not inspected but
Induction Furnace
MF701 ‐2 As above 1 expected to be as new. No visible
Power Supply
damage or corrosion
Induction Furnace
MF701‐3 crucible, power leads As above 1 lot Still in crate As new
pipe fittings etc
Induction Furnace
Sitting in open. Dusty but
closed circuit dry air
MF701‐4 4 radiator/fan units etc 1 otherwise as new. No visible
cooler, DC pump ,
damage
pump module
MF701‐5 Fume Exhauster Arm 1 Good condition on pallet
With 7 ea Pressure
guage , pressure 0‐100
SCR 480V 350 Ap/n
MF701‐6 psi , 6 ea thermometers 2 Still in crates
18EZ‐4‐3503P‐21C
50 ‐ 400 degrees F.
+bolts flanges etc
1000oz Au side pour
MF701‐7 5 In crate
molds
MF701 ‐8 Slag Pot 19" cast Iron 2 in crate
MF701‐9 Slag Pot Cart 1 Strapped on top of crate As new
Durco Centrifugal pump
PP601 Strip Solution Pump 1 As new. Very good condition
and motor
Minor damage to Motor Fan
Durco Centrifugal pump
PP602 Strip Solution Pump 1 cowling. Otherwise Very good
and motor
condition
PP701 Filter Feed Pump 1 Boxed
Durco Centrifugal pump
Barren Solution
PP702 and motor 1 As new. Very good condition
Pump
SVEE
No of
Equipment ITEM NAME DESCRIPTION COMMENTS
units
ID
Pump has suffered significant
shipping damage (dropped??).
Motor fan cowling needs
Durco Centrifugal replacement. Both motor and pump
PP801 Carbon Fines Pump 1
pump displaced from base (maybe
attempted repair). Both motor and
pump revolved freely suggesting
damage is not major
FRP Radial Fume
FA401 Acid Wash Vent Fan 1 Fan is in pristine condition. As new
Exhauster
Condition as new. No rust or
New York Blower corrosion. Paint and shaft
FA701 EW Cell Exhaust Fan 1
Centrifugal Fan protection coating still in place
Rotates freely
Very minor rust on fan shaft with
protective coating still in place and
Dust Collector Fan
FA702 New York Blower 1 no harm done. Shroud and other
and panel
painted surfaces in very good
condition
PS 701 Refinery Sump Pump 1 As new condition
Trench Collector
PS1001 1 As new condition
Pump
Acid Wash Feed As new. Currently some plates
PP401 1
Pump dismounted for shipping
Drive as new on pallet. Shaft dirty
Carbon Fines Tank Vertical tank mounted
AG801 1 but undamaged Agitator in
Agitator agitator
unopened box. V.G. condition
Drive as new on pallet. Shaft dirty
Carbon Attrition Tank Vertical tank mounted
AG802 1 but undamaged . Agitator in
Agitator agitator
unopened box. V.G. condition
Screen Wedgewire
PV501‐2 6 Unopened in crate
316 SS
Screen Wedgewire
TK401‐2 2 Unopened in crate
woven pvc
Lot Thermocouple wire 550 ft Boxed
SVEE No of
ITEM NAME DESCRIPTION COMMENTS
Equipment ID units
PLC Data logging
DSC384 Communication Cable 500 ft Boxed
System
LI2407‐1 Siemens MultiRanger 1 Boxed
LE2407 Seimens Echomax 1 Boxed
Misc PVC Assembly 1 Boxed
HX602 Heat Exchanger 1 Boxed
Assemblies for 3/8"
Gland seal 6 Boxed
piping
E/W Cell Cable Cutter For locomotive cable 1 Boxed
E/W Cells Cable lugs For locomotive cable 16 Boxed
Zinc Plated Washers 2 boxes
Serrated Washers 3 boxes
Hex 7/16 Nuts Zinc Plted 1 box
Bolts Hex 7/16 20 x
Zinc Plated 2 boxes
2"
Bolts Hex 7/16 20 x
Zinc Plated 2 boxes
2.5"
Gas Monitor and
Toxigard II 1 Boxed
Alarm
AI‐2403 pH Analyser probe 1 Boxed
TI 2575/TI Temperature
3 Boxed
2626/ TI 2637 Indicators
PI ‐
2636/PI2635/
PI2634/PI2791/ Pressure Indicators 7 Boxed
PI2701/PI2501/
PI2504
PI‐2804 Pressure Indicators w/diaphragm 1 Boxed
Misc Hose Clamps 7‐10" 18 2 boxes
Valves 1" Sharpe 58876 Ball threaded 4 Boxed
SVEE
No of
Equipment ITEM NAME DESCRIPTION COMMENTS
units
ID
Hose for 501‐1, 1.25
Hose Clear HCl compatible 30 ft Boxed
dia
Clamps 4 Boxed
1 in Thread to BARG
Misc 2 Boxed
Adapter
Pressure Control 5‐150 psi 1/2"NPT
2 Boxed
Valve 4759K23 w/guage
Pressure Control 5‐125 psi 1‐1/2"NPT
1 Boxed
Valve 4759K7 w/guage
Level Indicators with
LI2625 fittings, valves and 2 Boxed
tubing
TK401 1.5" PVC Nozzle 1 Boxed
PV 501/502/ Nozzle spray 1.5"
316 SS full cone 3 Boxed
SC 802 TF56FC
TK Nozzle spray 1.5"
316 SS Hollow cone 3 Boxed
802/803/804 TF56FC
Insertion/Submersion
AE 2403 ABB TBX551Ph/ORP 1 Boxed
Sensor
Hose Red Water 100 ft Boxed
Spiralite 090 water
Hose clear 090‐8 8" dia. 5 ft Boxed
suction
Hose HT‐8 Blue Flex hose 8" dia 5ft Boxed
Safety Eye Wash
Safety Encon 1 Still In box Very good condition
Shower
Model Still in Crate SS construction VG
SC802 Carbon Sizing Screen 1
SAA46BD1Xw/16# 48" Condition
Carbon Dewatering Model Still in Crate SS construction VG
SC801 1
Screen SAA46BD1Xw/16# 48" Condition
SVEE
No of
Equipment ITEM NAME DESCRIPTION COMMENTS
units
ID
Heavy duty Security As new condition Handle missing
Safe LACA Safe 1
safe (dismounted for shipping??)
New and undamaged in box Not
Piping Lot of Pipe Fittings Various Sizes CPVC 1
counted
Very good condition Tanks
Summit Valley
essentially stainless steel Complete
EW 701/702 E/W Cells Basketless Cathode 2
with supporting MS frames for
E/Wcells
installation on concrete foundation
For Summit Valley
Basketless Cathode
EW 701/702 Anodes and Cathodes As new in unopened crate
E/W cells 33 cathodes
36 anodes
Heavy Duty Locomotive
EW 701/702 Cell Cabling 825 ft On reel in good condition
cable
Lot of Carbon Steel Pipe flanges nuts and
Piping 1 As new for entire plant
Pipe and fittings bolts Schedule 40
Various sizes both
Piping Lot of valves 1
metal and plastic
Screens Screen wedgewire PVC 3" 2 As new still in box
No evidence of damage. Stored
TK 401 Acid Wash Vessel Fibre glass construction 1
outside under tarpaulins
Stored outside in yard Minor mostly
4 Tonne carbon cosmetic paint damage, with some
Carbon Elution Strip
PV 501/502 capacity ASME certified 2 rust areas in legs where standing
Vessels
CS Pressure Strip Vessel water was present. Minor internal
rust in non painted area
Stored outside under cover Good
Fibreglass holding tank
TK402 Dilute Acid Tank 1 condition except one external loose
for acid wash section
metal tab (shipping) Minor repair
Carbon Regeneration
KN801 Horizontal electric kiln 1 Stored outside under cover
Kiln
Complete with Bags
DC701 Dust Collector 1 Stored outside Good condition
internal bag supports
DC701 Ladder 1 Good condition in Warehouse
SVEE No of
ITEM NAME DESCRIPTION COMMENTS
Equipment ID units
High Pressure
SP701 Cathode wash 1 As New in box
Sprayer
Copper/Brass Piping
Piping For Drinking Water?? 1 lot Boxed as new
and fittings
Duct parts and
KN801/VFD801/ Duct parts in bag VFD's Boxed
fillings, 5HP VFD, 8 For kiln 1 lot
VFD501 unopened
HP VFD
Crated for shipping. Unopened box
KN801 SCR Panels Kiln 2 in good condition. No evidence of
damage/moisture
Remote Data logging
panel and local 2 Crates in good condition No
DCS384
panels/spool of crates evidence of damage or moisture
green wire
Galvanised Piping Package unopened no damage
Ducting Ducting accessories 1Pkg
Fittings visible
SA/701/702 Solution Samplers 2
PV501/502 Outlet Screens MS 2
Overflow Screens
PV501/502 2
MS
PV501/502 Spray Assembly MS 2
TK401 PVC Outlet ‐ Solution 1
TK401 PVC Inlet ‐ Solution 1
SS Inlet Flange 1
SS Outlet Flange 1 Crated. Not opened. No Evidence
SS Dust Collector 1 of any damage. Expected to be as
Carbon Discharge new condition. Vent fan stack
2 strapped on top, SS ,as new
Manifold
Carbon Dish cone 2
Fibreglass Flange
TK401 2
Adapters
FO2651 Flow Orifice 1
TK401 PVC Spray Assembly 1
EW Cell Fan Vent
1
Stack
1.5x 12 Johnson
MR901 1
Screen
SVEE
No of
Equipment ITEM NAME DESCRIPTION COMMENTS
units
ID
Mold Cart 1
PSV2505/
PVR Parts 1 lot
PSV2506
For Blow off protection
PRV manifolds 2
Columns
On small pallet‐ two blue 6" dia. x
Blow off Protection
2 36' pipe with flange for bolting
Columns
down
3" x 21" CS Pipe for
2 Loose on Warehouse floor
PRV manifolds
Includes nuts and bolts bagged on
Piping Pipe Materials
pallet
Fittings on Pallet OK. Ducting not
316 304 SS Duct
12‐VP‐PVC‐713 all there. Remaining: 2ea 8"dia x
and fittings
~3m long, 2 ea 14' dia. x 10’ long
w/ start stop High
Hand Stations Sold
low
Stored outside In good condition
Hopper/ Feed Bin Minor rust in interior. Some rust
TK801 98"W x 96"H x 18'6" L
for kiln development on legs (Sandblast
and paint.)
Section 4
Plant Layout
Drawings
Section 5