Anda di halaman 1dari 6

23.

COOLER BOTTOM
Fungsi : Mendinginkan produk bawah Menara Distilasi ( Bottom ), sebelum masuk ke
dehidrator.
Tipe : Shell and Tube
Media : Air
Temperatur : 28 – 40oC
1. Berdasarkan Neraca Massa dan Neraca Panas
Jumlah panas yang didinginkan ( Q )
Q = kkal/jam x 3,968 Btu/kkal
= Btu/jam
Jumlah air pendingin yang digunakan ( Wair )
Wair = kg/jam x 2,205 lb/kg
= lb/jam
Jumlah larutan yang akan didinginkan ( Wlar )
Wlar = kg/jam x 2,205 lb/kg
= lb/jam
2. Selisih Temperatur Rata-rata ( Δt )

( GAMBAR )

t1 = oC = oF
t2 = oC = oF
T1 = oC = oF
T2 = oC = oF
Δth = T1 - t2 = oF
= oF
Δtc = T2 – t1 = oF
Maka :
Δt h− Δt c
LMTD =
ln Δt h/ Δt c
=
= oF
3. Temperatur Kalorik ( Tc dan tc )
Temperatur rata-rata fluida panas ( Tc )
T 1+T 2
Tc =
2

= 2

= oF
t 1+t 2
tc =
2

= 2

= oF
Δt = Ft x LMTD
T 1−T 2
R =
t 2−t 1
T 1– T 2
=
t2– t1
=
t 2−t 1
S =
T 1−t 1
t 2−t 1
=
T 1−t 1
=
Berdasarkan R dan S, maka dari Fig.19 Kern diperoleh Ft = 0,90
Δt = 0,90 x LMTD
= oF
Dari Table 8 Kern diperoleh UD = 250 – 500 Btu/jam.ft2 oF
Dicoba UD = 298 Btu/jam.ft2 oF
Sehingga :
Q
Ao =
UD x Δt
Btu/ jam
=
Btu / jam . ft 2 o F
= ft2
Pemilihan Heat Exhanger :
Dipilih HE ukuran ¾ in OD, 16 BWG, 15/16 in Triangular Pitch, dengan panjang pipa
16 inch, maka dari Tabel 10 Kern, diperoleh :
OD = 0,75 in
ID = 0,62 in = 0,0517 ft
Pt = 15/16 in
a’t = 0,302
a” = 0,1963
L = 16 ft
C = 0,1875 in
Jumlah pipa yang digunakan ( Nt ) :
Ao
Nt =
a”x L
ft 2
= 0,1963 ft 2
x 12 ft
ft
= buah
Dari Tabel 9 Kern, diperoleh :
IDshell = 10 in
Nt = buah
n = 4 pass
Luas penampang terkoreksi ( A ) :
A = Nt x a” x L
=
= ft2
Koefisien perpindahan panas terkoreksi ( UD )
Q
UD =
A x∆t
Btu / jam
=
ft 2 x❑o F
= Btu/jam.ft2.oF
( Memenuhi syarat, karena UD terkoreksi lebih besar dari UD trial )
Fluida panas ( Shell side )
4. Luas penampang ( As )
ID x C x B
As =
144 x Pt
ID x C x B
=
144 x Pt
= ft2
5. Kecepatan alir massa ( Gs )
Ws
Gs =
As
lb / jam
=
ft 2
= lb/jam ft2
6. Bilangan Reynold ( Res )
Sifat fisis pada Tc = 154,4oF
k = 0,355 lb/jam.ft2
Cp = 1,00 Btu/lboF
µ = 0,86 cp x 2,42 = 2,0812 lb/jam.ft
De = 0,73 in = 0,0608 ft
Gs x De
Res =
µ
lb
. ft 2 x 0,0608 ft
jam
=
lb
2,0812 . ft
jam
=
7. JH = 38 …………………………………… ( Table 29. Kern )
8. Koefisien perpindahan panas ( ho )
k
ho = JH x ( ) x( µwµ )
De
x
Cp x µ
k
1 /3 0,14

k Cp x µ µ
x( ) x(
µw )
1 /3 0,14
= 57 x
De k
= Btu/jam.ft2oF
9. Koefisien perpindahan panas keseluruhan bersih ( Uc )
hio x ho
Uc =
hio +ho
hio x ho
=
hio +ho
= Btu/jam.ft2oF
10. Faktor pengotor ( Rd )
Dari data fouling factors Table 8 Kern
Rd = 0,001
Sehingga :
Uc−UD
Rd =
Uc x UD
Uc−UD
=
Uc x UD
= jam.ft2.oF
Karena Rd rancang ≥ Rd ketentuan, maka dilakukan pengecekan terhadap Pressure
Drop.
Penetuan Pressure Drop
Fluida panas ( Shell Side )
1. Res =
f = 0,0021 ……………………………...... ( Fig 29 Kern )
2. Jumlah lewatan ( Nt )
12 x L
N+1 =
B
12 x L
=
B
= kali
s = 0,0967 ……………………………… ( Fig 6 Kern )
8
Ds =
12
= ft
3. Menentukan Pressure Drop ( Δ Ps )
f x Gs2 x Ds x ( N +1 )
Δ Ps =
5,22.1010 x De x ϴs
f x Gs2 x Ds x ( N +1 )
=
5,22.1010 x De x ϴs
= Psi
Fluida dingin ( Tube )
1. Menentukan Friction Loss ( f )
Gt = lb/ft2jam
Ret =
F = 0,00009 ………………………………….( Fig.26 Kern )
f x ¿2 x L x N
2. Δ Pt = ½ x
5,22.1010 X De x s x ϴ
f x ¿2 x L x N
=½x
5,22.1010 X De x s x ϴ
= Psi
3. Menentukan Pressure Drop rancang ( Δ PT )
4 x n (V )2
Δ PT = x
sg 2g
4 x n (V )2
= x
sg 2g
= Psi
4. Menentukan Pressure Drop total ( ΔP )
ΔPtot = Δ Pt + Δ PT
=
= Psi
Kesimpulan :
Karena ΔPtot = Psi ≤ 10 Psi, maka perancangan alat ini memenuhi syarat dan layak
digunakan.