Anda di halaman 1dari 2

http://digilib.its.ac.

id

SUMMARY

PEMODELAN TRANSFORMATOR SATU FASA MENGGUNAKAN


CONSTRUCTIVE BACKPROPAGATTON

MODELING ONE PHASE TRANSFORMER USING CONSTRUCTIVE BACK PROPAGATION

Created by RIJANTO, TRI

Keyword : : Jaringan saraf tiruan; constructive backpropagation; transformator satu fasa.

Description :
Model transformator menjadi penting diinformasikan karena digunakan untuk kebutuhan operasi. Untuk memodelkan
transformator digunakan jaringan saraf tiruan, sedangkan pembelajaran yang digunakan adalah constructive
backpropagation (CBP). Algoritma jaringan saraf tiruan yang digunakan menerapkan metode pemetaan non linier yang
akan mempolakan input data transformator satu fasa keadaan berbeban, beban kosong, dan hubung singkat. Untuk
efisiensi kerja jaringan, data input terlebih dahulu dinormalisasi.
Hasil penelitian menunjukkan bahwa constructive backpropagation neural network dapat digunakan untuk memodelkan
transformator kondisi berbeban, beban kosong, dan hubung singkat. Konfigurasi jaringan terbaik berturut-turut adalah
(1) pada kondisi transformator berbeban terdiri dari 4 unit input dan 3 unit output tanpa adanya penambahan hidden unit
baru dengan persentase rata-rata kesalahan 2,3866%, (2) pada kondisi transformator beban kosong terdiri dari 3 unit
input dan 1 unit output tanpa adanya penambahan hidden unit baru dengan persentase rata-rata kesalahan 4,8552%, dan
(3) pada kondisi transformator hubung singkat terdiri dari 2 unit input dan 3 unit output dengan penambahan 1 hidden
unit baru dengan persentase rata-rata kesalahan 6,316%. Dan hasil pelatihan memperlihatkan model transformator
berbeban, beban kosong, dan hubung singkat sesuai dengan model referensi

Description Alt:
Transformer model is very important to be known for operation demand. Transformer was modelled using artificial
neural network with constructive backpropagation algorithm for learning process. The artificial neural network
employed non linier for to draw the pattern input data of one phase transformer in load, no load, and short circuit
condition. To determine network efficiency, input data were normalized previously.
Analysis result shown that constructive backpropagation neural network can be used for modelling transformer in load,
no load, and short circuit condition. The best configurations network were respectively (1) 4 input unit and 3 output unit
without new hidden unit added result average sum of square error 2.3866% for the load condition, (2) 3 input unit and 1
output unit without new hidden unit added result average sum of square error 4.8552% for no load condition, and (3) 2
input unit and 3 output unit with 1 new hidden unit added result average sum of square error 6.316% for the short circuit
condition.. Training result shows that transformer model in load, no load, and short circuit can achieve reference model
succesfully.

Contributor : Dr. Ir. Mauridhi Hery Purnomo, M.Eng.

Date Create : 07/01/2007

Type : Text

Format : Pdf; 50 pages

Language : Indonesian

Page 1
Identifier : ITS-Master-3100097008566

Collection : 3100097008566

Call Number : 621.384 56 And

Source : Theses Power System RSE 621.384 56 And s-1, 1996

COverage : ITS Community

Right : Copyright @1996 by ITS Library. This publication is protected by copyright and permission
should be obtained from the ITS Library prior to any prohibited reproduction, storage in a
retrievel system, or transmission in any form or by any means, electronic, mechanical,
photocopying, recording, or likewise. For information regarding permission(s), write to ITS
Library

Full file - Member Only


If You want to view FullText...Please Register as MEMBER

Contact Person :
Mr. Edy Suprayitno (edy_supra@its.ac.id)
Mrs. Ansi M. Putri(ansi@its.ac.id)
Mr. Agus Setiawan (setiawan04@its.ac.id)
Mrs. Dewi Eka Agustina (dee@its.ac.id)

Thank You,

Nur Hasan
ITS Digilib Supervisor

Page 2

Anda mungkin juga menyukai