This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Input data
Geometry
Biggest floor area: 142 [m2]
Brutto floor area: 142 [m2]
Net floor area: 142 [m2]
Heated floor area: 142 [m2]
Average ceiling height: 2.70 [m]
Building perimeter: 43.0 [m]

Lowest floor slab


Floor slab on the soil: 142 [m2]
Unheated basement: 0 [m2]
Heated space: 0 [m2]
Unheated space: 0 [m2]
Arcade: 0 [m2]

Vertical insulation
Geodetic height: 0.30 [m]
Thermal resistance: 4.50 [m2K/W]
Depth of thermal insulation: 0.50 [m]
Horizontal insulation
Geodetic height: 0.30 [m]
Thermal resistance: 4.00 [m2K/W]

Roof: Garret with outer parapet


Pitched roof: Exists
Heated attic Exists

Density of internal partitions: Average


Configuration in layout: Simple
Configuration in section: Compact

Elevation areas:
Wall between heated and unheated spaces: 10 [m2]
Elevation area, including exposed and facing to sunspace
Facing to N: 25 [m2]
Facing to NE: 0 [m2]
Facing to E: 50 [m2]
Facing to SE:: 68 [m2]
Facing to S: 82 [m2]
Facing to SW: 68 [m2]
Facing to W: 50 [m2]
Facing to NW: 0 [m2]

Facade elements in section Facade elements in projection


N: None -----------
E: None -----------
SE: None -----------
S: None -----------
SW: None -----------
W: None -----------
This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Transparent elements
Glazing
N: 4 [m2] Direct input (U=1.90 g=0.75)
E: 3 [m2] triple glazing,wooden+Alu frame
SE: 0 [m2] triple glazing,wooden+Alu frame
S: 1 [m2] triple glazing,wooden+Alu frame
SW: 0 [m2] triple glazing,wooden+Alu frame
W: 4 [m2] triple glazing,wooden+Alu frame

Mullion
Orient. Mullion Perimeter/area Movable shading
N: Sparse Average External blind
E: Average Average External blind
SE: Very sparse Very small Curtain
S: Sparse High Direct input (R=0.18 g=0.30)
SW: Very sparse Very small Curtain
W: Average Average External blind

Tilted glazing
Orient. Area Tilt Window type
NE: 3 [m2] 45 Medium 0.9 - 1.2 m2, 2 rtg
SE: 3 [m2] 45 Direct input (U=2.10 g=0.40)

Indirect systems
Sunspace data:
Orient. Area [m2] Window area [m2] ACH. [1/h] Window type Glazing type.

Orient. Frame Roof Layout Movable shading

Mass wall data:


Orient. Area Mullion Glazing Night insulation Surface finishing

Trombe wall data:


Orient. Area Mullion Glazing Movable shading Surface finishing

Transparent insulation data:


Orient. Area Mullion Movable shading Transmittance TRI R Opaque wall R

Solar access
Solar access:
Orient. Building in layout Building in section Deciduous vegetation Evergreen vegetation
N: none none none none
E: none none none none
SE: none none none none
S: none none none none
SW: none none none none
W: none none none none
This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Constructional data
Constructional data
Floor covering in rooms, facing to
Orient. Floor covering
N: Medium
E: Medium
SE: Light
S: Heavy
SW: Light
W: Medium

Position of thermal insulation: External


Specific mass of exposed wall: 1400-1700 kg/m3
Specific mass of floor slabs: medium
Specific mass of partition walls: 160-200 kg/m2

Building use
Indoor set temperature: 20.0 [°C]
Design external temperature: -13.0 [°C]
Air change per hour: 0.7 [1/h]
Heat recovery: None
Building use: Residential
Heating system control: average
Number of occupants - conventional heat gain: 5 [capita]

Summer ventilation of rooms facing to


N: intensive
E: intensive
SE: not intensive
S: intensive
SW: not intensive
W: intensive

Fuel data:
Fuel price per MJ: 3.0
Heat value per other unit: ------
Efficiency of heating system: 81.00
This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Output
Regarding summer overheating the thermal mass is :
for N orientation acceptable
for E orientation acceptable
for S orientation acceptable
for W orientation acceptable

Heat transfer coefficient {thermal resistance}:


Exposed walls: 0.25 { 4.00}
Walls between heated and unheated spaces: 0.00 { 0.00}
Heated attic envelope: 0.00 { 0.00}

Heat load: 8.4 [kW]


Yearly heating energy cost: 166401

Average U value: 0.169 [W/m2K]


Average thermal resistance: 5.905 [m2K/W]
Average U value including thermal bridge effect: 0.201 [W/m2K]
Average thermal resistance including thermal bridge effect: 4.965 [m2K/W]
Transmission heat loss coefficient: 162.987 [W/K]
Transmission heat loss coefficient per floor area: 1.148 [W/Km2]
Transmission heat loss coefficient per volume: 0.425 [W/Km3]
Heat loss coefficient: 254.236 [W/K]
Heat loss coefficient per floor area: 1.790 [W/Km2]
Heat loss coefficient per volume: 0.663 [W/Km3]
Net balance of transmission losses and utilised direct solar gains: 152.228 [W/K]
Net balance of transmission losses and utilised direct solar gains per floor area: 1.072 [W/Km2]
Net balance of transmission losses and utilised direct solar gains per volume: 0.397 [W/Km3]
Net heat loss coefficient: 165.722 [W/K]
Net heat loss coefficient per floor area: 1.167 [W/Km2]
Net heat loss coefficient per volume: 0.432 [W/Km3]
Heating energy consumption per floor area: 88 [W/m2]
Heating energy consumption per volume: 33 [W/m3]

Informative data

Month Total heat gain Utilised heat gain Heating energy consumption
[kWh/day] [kWh/day] [kWh/month]
1. 28.5 28.5 3050.7
2. 31.4 31.4 2350.2
3. 35.6 34.9 1546.9
4. 40.5 36.9 486.2
5. -- -- 0.0
6. -- -- 0.0
7. -- -- 0.0
8. -- -- 0.0
9. -- -- 0.0
10. 34.0 31.0 590.9
11. 29.7 29.7 1781.2
12. 27.8 27.8 2674.0

Sum: 12480.0
This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Energy consumption of auxiliary heating

[kWh/month]
5000.0

4000.0

3000.0

2000.0

1000.0

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12.