Anda di halaman 1dari 4

TeSys contactors

Dimensions

Model d contactors
Control circuit: a.c.

LC1 D09D18 (3-pole)

LC1 D25D38 (3-pole), LC1 DT20DT40 (4-pole)


44

44
Minimum electrical
clearance

Minimum electrical
clearance

LA4

b1

b1

LA4

10

12,5
(LAD 8)

c
c1
c2
c3

LC1
b without add-on blocks
b1 with LAD 4BB
with LA4 Dp2
with LA4 DF, DT
with LA4 DW, DL
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
c2 with LA6 DK10, LAD 6K10
c3 with LAD T, R, S
with LAD T, R, S and sealing cover
(1) Including LAD 4BB

45

10

12,5
(LAD 8) (1)

D09D18 D093
D123
77
99
94
107
110 (1)
123 (1)
119 (1)
132 (1)
126 (1)
139 (1)
84
84
86
86
117
117
129
129
137
137
141
141

12,5
(LAD 8)

c
c1
c2
c3

D099
D129
80
95.5
111.5 (1)
120.5 (1)
127.5 (1)
84
86
117
129
137
141

LC1 D40D65 (3-pole), LC1 D65004, D40008 & D65008 (4-pole)

D25
D38
85
98
114 (1)
123 (1)
130 (1)
90
92
123
135
143
147

D183
D323
99
107
123 (1)
132 (1)
139 (1)
90
92
123
135
143
147

DT20 &
DT25
85
98
114
129
190
97
99
123
135
143
147

c
c1
c2
c3

LC1
a
b1 with LA4 Dp2
with LA4 DB3
with LA4 DF, DT
with LA4 DM, DW, DL
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N (1 contact)
with LAD N or C (2 or 4 contacts)
c2 with LA6 DK
c3 with LAD T, R, S
with LAD T, R, S and sealing cover

DT323 &
DT403
105

105
107
131
143
151
155

32 44
Minimum electrical
clearance

12

12,5
(LAD 8)

D40D65
75
135

142
150
114
119
139
147
159
167
171

b1

LA4

127

b1
12,5
(LAD 8)

DT32 &
DT40
91

105
107
131
143
151
155

LC1 D80 & D95 (3-pole), LC1 D80004 & D80008 (4-pole)

LA4

127
12

12,5
(LAD 8) (1)

DT203 &
DT253
99

97
99
123
135
143
147

32 44
Minimum electrical
clearance

45

D40008
85
135

142
150
125

139
147
159
167
171

c
c1
c2
c3

12,5
(LAD 8)

D80, D65004
85
135
135
142
150
125
130
150
158
170
178
182

D95, D65008
85
135

142
150
125
130
150
158
170
178
182

12,5
(LAD 8)

D80004
96
135

142
150
125

150
158
170
178
182

D80008
96
135

142
150
140

150
158
170
178
182

LC1 D115 and D150 (3-pole), LC1 D115004 (4-pole)

Selection :
pages 24565/2 to 24572/5

24531-EN_Ver7.0.fm/2

D115004
150
174
185
188
188
132

150
155
168
172

Characteristics :
pages 24505/2 to 24505/7

D115006
120
174
185
188
188
115

150
155
168
172

D150006
120
174
185
188

115

150
155
168
172

D1150046
155
174
185
188
188
115

150
155
168
172

References :
pages 24501/2 to 24502/3

Minimum electrical
clearance

LAD 8

LA4

10
b1

D115, D150
120
174
185
188
188
132
136
150
155
168
172

158

LC1
a
b1 with LA4 DA2
with LA4 DF, DT
with LA4 DM, DL
with LA4 DW
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
c2 with LA6 DK20
c3 with LAD T, R, S
with LAD T, R, S and sealing cover

c
c1
c2
c3

Schemes :
pages 24532/2 and 24532/3

TeSys contactors

Dimensions

Model d contactors
Control circuit: d.c. or low consumption

LC1 D09D18 (3-pole)

LC1 D25D38 (3-pole)

Minimum electrical
clearance

10

Minimum electrical
clearance

45

45

10

c1
c2
c3

c1
c2
c3

LC1
b
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
c2 with LA6 DK10
c3 with LAD T, R, S
with LAD T, R, S and sealing cover

D09D18
77
93
95
126
138
146
150

D093D123
99
93
95
126
138
146
150

D099D129
80
93
95
126
138
146
150

D25D38
85
99
101
132
144
152
156

D183D323
99
99
101
132
144
152
156

DT20 & DT25


D098 & D128
85
99
123
135
143
147

DT203 & DT253


D0983 & D1283
99
99
123
135
143
147

DT32 & DT40


D188D258
91
107
131
143
151
155

DT323 & DT403


D1883 & D2583
105
107
131
143
151
155

LC1 DT20 to DT40 (4-pole)

Minimum electrical
clearance

45

10
c1
c2
c3
LC1
b
c
c1
c2
c3

with cover
with LAD N or C (2 or 4 contacts)
with LA6 DK10
with LAD T, R, S
with LAD T, R, S and sealing cover

LC1 D40D65 (3-pole)


LC1 D65004, LP1 D40008D65008 (4-pole)

LC1 D80 & D95 (3-pole)


LP1 D80004, LP1 D80008 (4-pole)
Minimum electrical
clearance

127

127

Minimum electrical
clearance

12

85

12

c1
c2
c3
LC1
D40D65
c without cover or add-on blocks
171
with cover, without add-on blocks
176
c1 with LAD N (1 contact)
196
with LAD N or C (2 or 4 contacts)
202
c2 with LA6 DK10
213
c3 with LAD T, R, S
221
with LAD T, R, S and sealing cover
225
LC1 D115ppp and LC1 D150ppp with c coil: see page 24531/2
Selection :
pages 24565/2 to 24572/5

96

c1
c2
c3

Characteristics :
pages 24505/2 to 24505/7

LP1 D65004
171

196
202
213
221
225

References :
pages 24501/2 to 24502/3

LP1 D40008
& D65008
182

196
202
213
221
225

LC1
D80 & D95
181
186
204
210
221
229
233

LP1 D80004

LP1 D80008

181

204
210
221
229
233

196

204
210
221
229
233

Schemes :
pages 24532/2 and 24532/3

24531-EN_Ver7.0.fm/3

TeSys contactors

Mounting

Model d contactors

LC1 D09D38, DT20DT40

LC1 D40 to D95, LP1 D40 to D80


On mounting rail AM1 DL200 or DL201 (width 75 mm)
On mounting rail AM1 EDppp or AM1 DE200 (width 35 mm)

127

On mounting rail AM1 DP200, DR200 or AM1 DE200 (width 35 mm)

c
c

LC1
b
c
c

D09D18 D25D38 DT2


& DT25
77
85
85
(AM1 DP200 or DR200) (1)88
94
94
(AM1 DE200) (1)
96
102
102

Control circuit: d.c.


b
77
c (AM1 DP200 or DR200) (1)97
c (AM1 DE200) (1)
105

85
103
110

94
103
111

Control circuit: a.c.


LC1

DT32
& DT40
100
109
117

c
c
c

109
118
1236

Control circuit: d.c.


LC1
c (AM1 DL200) (1)
c (AM1 DL201) (1)

(AM1 DL200) (1)


(AM1 DL201) (1)
(AM1 EDppp or DE200) (1)

LP1
c (AM1 DL200)
c (AM1 DL201)
(1) with safety cover.

(1) with safety cover.

D40D65

D80 & D95

136
126
126

147
137
137

D40D65
193
183

D80 & D95


203
203

D40
188
178

D65
188
178

D80
198
198

LC1 D115, D150

158

100

On 2 mounting rails DZ5 MB on 120 mm centres

Control circuit: a.c. or d.c.


LC1
c (AM1 DP200 or DR200)
c (AM1 DE200 or EDppp)

D115 & D150


134.5
142.5

D1156 & D1506


117.5
125.5

Control circuit: a.c.


LC1
c with cover

D40D65
119

D80 & D95


130

Control circuit: d.c.


LC1
c with cover

D40D65
176

D80 & D95


186

LP1
c

D40 & D65


171

D80
181

LC1 D40D95, LP1 D40D80


On 2 mounting rails DZ5 MB on 120 mm centres

Selection :
pages 24565/2 to 24572/5

24531-EN_Ver7.0.fm/4

15

110

120

DZ5 ME5

40

Characteristics :
pages 24505/2 to 24505/7

References :
pages 24501/2 to 24502/3

Schemes :
pages 24532/2 and 24532/3

TeSys contactors

Mounting (continued)

Model d contactors

LC1 D09 to D38 and LC1 DT20DT40


On 2 mounting rails DZ5 MB
Control circuit:
LC1
c with cover
G
H
H1
4-pole contactors
LC1

H1

DZ5 ME8

15

c
G
H
H1

LC1 D09D38 and LC1 DT20DT40

a.c.
D09D18
86
35
60
70

D25D38
92
35
60
70

d.c.
D09D18
95
35
70
70

D25D38
101
35
70
70

DT20
& DT25
92
35
60
70

DT32
& DT40
100
35
60
70

DT20
& DT25
101
35
70
70

DT32
& DT40
109
35
70
70

LC1 D40D95, LP1 D40D80


On pre-slotted mounting plate AM1 PA, PB, PC

110

On pre-slotted mounting plate AM1 PA, PB, PC

AF1 EA4

c
Control circuit:
LC1
c with cover
G
H
LC1

a.c.
D09D18
86
35
60/70
DT20
& DT25
80
35
60

c with cover
G
H

d.c.
D09D18
95
35
70
DT20
& DT25
118
35
60

D25D38
92
35
60/70
DT32
& DT40
93
35
60

D25D38
101
35
70
DT32
& DT40
132
35
60

LC1 D09D38

40

Control circuit:
LC1
c with cover
LP1
c without cover

a.c.
D40D65
119

D80 & D95


130

AF1 EA6
d.c.
D40D65
176
D40 & D65
171

LC1 D40D95, LP1 D40 D80


DC

AC

Panel mounted

2xM4

2x4,5

Control circuit:
LC1
c with cover
4-pole contactors
LC1
c

with cover

35

100/110
=

50

60/70

2xM4

Panel mounted

D80 & D95


186
D80
181

35

a.c.
D09D18
86

D25D38
92

d.c.
D09D18
95

D25D38
101

DT20
& DT25
90

DT32
& DT40
98

DT20
& DT25
90

DT32
& DT40
98

Control circuit:
LC1
c with cover
LP1
c

without cover

40

3x6,5

a.c.
D40D65
119

D80 & D95


130

d.c.
D4D65
176

D40 & D65 D80

171

181

D115
132
96/110
130/144

D1156
115
96/110
130/144

D150
132
96/110

D1506
115
96/110

D80 & D95


186

LC1 D115, D150

130
158

Panel mounted

Selection :
pages 24565/2 to 24572/5

Characteristics :
pages 24505/2 to 24505/7

LC1
c
G (3-pole)
G (4-pole)
References :
pages 24501/2 to 24502/3

Schemes :
pages 24532/2 and 24532/3

24531-EN_Ver7.0.fm/5