1.1.1 This specification sets out the minimum requirements for the supply and installation of a Category I Instrument Landing System (ILS) complete with high intensity approach lighting and Tower(s). 1.1.2 The installed system shall include the Localizer and Glideslope stations and the necessary accessory equipment for a complete installation. The systems shall be of a solid state design and each shall include an electronics subsystem, antenna system, shelter-to-antenna system cables, installation and interface kits, no-break battery backup system of the maintenance free design and necessary accessory items such as extender boards and cables and wattmeter elements. 1.1.3 The systems shall all be microprocessor controlled and shall have been designed for ease of installation, high reliability, maximum attention to fail safe characteristics in all monitoring systems, enhanced system security, the minimum number of required control and telephone lines and maximum attention to equipment and personnel safety. Circuit breakers and fuses on AC & DC power lines and internal circuits shall offer maximum protection for the equipment. Surge suppression devices shall be installed in all electronic equipment shelters. System software shall have been designed in accordance with RTCA DO-178. The systems shall be designed around a plug and play philosophy to the maximum extent possible where replacement modules are automatically configured for their correct operating parameters when inserted in the system cabinet. Operator interfaces to the system using computers shall be designed around Windows based operating software. 1.1.4 The Localizer and Glideslope Electronic Subsystems shall consist of a Capture-Effect dual transmitter, dual monitor configuration of a modular design. The all solid state systems shall be housed in a single cabinet which is designed for mounting on the wall of an equipment shelter. The cabinets shall feature front access for all major components and may be designed in a hinged, swingout arrangement to allow access for installation and any rear mounted components. The Localizer and Glideslope shall be easily field upgradeable from Category I to Category III with the addition of a FFM ( Far Field Monitor ) 1.1.5 The Localizer antenna system shall consist of a 14-element, wide aperture Log Periodic Dipole (LPD) array of the Capture-effect design. The antenna system shall be furnished with all antenna elements and frangible supports, centrally mounted RF distribution/monitor combining unit, cable raceway, all coaxial feed and monitor cables, obstruction lighting and all civil and grounding kits needed for a complete installation. The array shall include integral monitoring pickup devices in each of the antenna elements. The antenna system shall include Antenna/ Feedline/ RF Distribution unit/ RF Combining unit, Fault monitoring circuitry, as well as provisions for generating a station alarm should any of the elements in the array become misaligned from its normal position. The height of the array shall be the minimum practical for the design. 1.1.6 The Glideslope antenna system shall be of the capture-effect design and utilize an array of three directional antennas mounted on a triangular steel tower with integral ladder. The system shall be furnished with antenna elements, transmitting tower, coaxial feed and monitor cables, obstruction lighting and all civil and grounding kits needed for a complete installation. The antenna system shall include integral monitoring using pickup devices in each of the array elements.
Page 1
c) Monitor bypass capability with indications for the Main and Standby Transmitter monitoring systems. d) Provisions for either Local or Remote control of the transmitting equipment. e) System reset capability.
f) Automatic transfer capability from the Main to the Standby transmitting equipment in the event of an alarm condition.
Page 2
i) Monitoring of environmental parameters including Intrusion detector, temperature and smoke sensors, obstruction lighting; j) Monitoring of Primary AC power applied to the system and Standby Battery Voltage and Current.
Page 3
1.2.1 The ILS system shall operate in a fixed, sheltered environment but with ambient operating temperature from (-10 Celsius to +50 Celsius) while the antenna, and associated cables, connectors and mounting hardware will operate in an outdoor environment. 1.3. Applicable Documents
1.3.1 The following Specifications, Standards and Publication of the issue in effect on the date of Invitation to Tender form a part of this specification to the extent specified herein. 1.3.1.1 ICAO - Annex 10, Volume I, International Standards and Recommended Practices th Aeronautical Telecommunications Annex 10 to the convention on International Civil Aviation, 6 Edition, dated July 2006 including all amendments up to the date of the contract. 1.3.1.2 ICAO Publications Documents Sales Unit International Civil Aviation Organization 999 University Street Montreal, Quebec Canada H3C 5H7 Precedence of Specification
1.4
1.4.1 Where a conflict occurs between this Specification and any other Specification or document referred to in paragraph 1.3 above, the requirements of this specification shall take precedence.
Page 4
1.5
General Requirements
1.5.1 Unless specified to the contrary (in subsequent parts hereof) the requirements stated in this Section 1 shall apply to the overall equipment. Each equipment furnished by the Bidder shall be complete in accordance with all specification requirements. 1.6 Patent and Claims Release
1.6.1 The successful Bidder shall protect, and defend and save harmless the City against any demand for patent fees or other claims of any description for any patented invention, article or arrangement that may be used in the construction or form any part of the articles delivered under the contract or the method necessitated by their use. 1.7 Spares
1.7.1 Sparing shall be carried out according to the criteria stated in the following paragraphs, with life cycle spares requirements being determined before delivery. 1.7.1.1 Spare Parts - Bidders shall include in their proposal the quantities of spares and their costs and breakdown which they deem the City should purchase in order to support all systems over the life expectancy of the equipment. The spares considered shall be: 1.7.1.1.1 1.7.1.1.2 Station Spares Consumable Spares
1.7.1.2 Station Spares - Station spares shall consist of spare Printed Wiring Boards (PWBs), modules, and assemblies to permit equipment repair. These shall be chosen according to the principle of one spare for each unique module in the system 1.7.1.3 Quality of Spares - Spares (modules, PWBs, assemblies and components parts) shall be of the same quality as originally installed. Spares shall be subject to the same parts selection criteria, quality control and testing (including temperature cycling) as original equipment. 1.7.1.4 Delivery of Spares - The delivery of spares shall be coincident with system delivery. They shall be considered part of the delivered system. 1.8 Test Equipment
1.8.1 The Bidder shall provide a list of test equipment which will be required to maintain the system. Information provided for each item of test equipment shall include, but not be limited to, the following: 1.8.1.1 Intended use. 1.8.1.2 Suggested Model. 1.8.1.3 Manufacturer or source of supply. 1.8.1.4 Approximate cost. 1.9 Packing and Shipping
1.9.1 The successful bidder shall be responsible for the packing, marking of cartons, invoices and ensuring equipment and spares arrive at the destination listed on the Schedule in an undamaged and serviceable condition, packaged and ready for onward shipment to a final destination.
Page 5
1.10
Safety Requirements
1.10.1 The successful bidder shall ensure that the equipment meets all applicable safety requirements and codes. 1.11 Definitions
1.11.1 For the purpose of this specification, in addition to the definitions given in related documents, the following terms shall have the given meanings: 1.11.1.1 Alarm - The term alarm used in conjunction with monitoring, shall denote a situation in which an out-of-tolerance condition, as sensed by the monitor equipment, has existed for a minimum period of time. 1.11.1.2 Local - Refers to the site where the ILS is located.
1.11.1.3 Lowest Replaceable Module (LRM) - An LRM is a subassembly which is designed for easy removal from the system. It cannot be disassembled except for removal of permanently fixed device leads. A part which has no effect on system performance or integrity, such as chassis indicator or display, will not be considered an LRM. Hereafter, the word module shall refer to Lowest Replaceable Module. 1.11.1.4 Maintenance Mode - A system is said to be in a maintenance mode when it has been placed out-of-service by a technician for maintenance purposes and/or configuration changes. The executive monitors continue functioning except that all executive actions are inhibited. 1.11.1.5 Normal Mode - A system is said to be in a normal mode when its executive monitors are fully enabled and capable of performing executive actions, such as causing an equipment changeover or shutdown when an out-of-tolerance condition occurs. No maintenance actions are to be performed on a system in the normal mode. 1.11.1.6 designated. 1.11.1.7 Remote - Refers to the Maintenance Center, Control Tower, or any other position so
Site - The place where the ILS system and other equipment is located.
1.11.1.8 Special Tools and Test Equipment - Those that are not carried as a standard off-theshelf line by the Contractor or any other manufacturer. 1.12 1.12.1 1.12.2 1.12.3 1.12.4 1.12.5 1.12.6 1.12.7 Abbreviations ANSI: American National Standards Institute BITE: CLR: CSB: DDM: FRP: Built-In Test Equipment Clearance Signal Carrier Plus Sidebands Signal Difference in Depth of Modulation Fiberglass Reinforced Plastic
Page 6
Instrument Landing System Lowest Replaceable Module Power Amplifier Printed Wiring Board Sidebands-Only Signal Sum of the Depths of Modulation of 90 Hz and 150 Hz signals
2.1.1 This section defines the mechanical requirements for the electronic equipment and the antenna systems. 2.2 Electronic Equipment
2.2.1 Configuration - All electronic assemblies, with the exception of the antenna systems, portable maintenance date terminal and remote equipment, shall be mounted in cabinet assemblies. The cabinet assemblies shall be wall mountable. 2.2.2 Equipment Unit Construction - The equipment shall be designed so that all modules and chassis components are easily accessible for maintenance. 2.2.3 Special Tools - Special tools, if required, shall be supplied as detailed in Section 1.9 of this Specification. 2.2.4 Hardware - The hardware configuration shall be such as to facilitate the repair and replacement of mechanical parts. Where required for measurement or adjustment, one printed wiring extender board shall be provided for each unique type of connector used in the system. 2.2.5 Wiring - All wiring materials shall be marked, identified, arranged and protected according to good practices. In addition, all primary power wiring within the equipment and incoming A.C. supply wiring shall be color coded. 2.2.6 Module Insertion and Removal - All modules and PWB's shall be fitted with a handle or lever to enable them to be easily and positively inserted and removed. Where practicable, handles or levers shall be permanently affixed to each module or PWB. Removable handles or levers shall be stored in the equipment chassis, close to where they are to be used. 2.2.7 Module Keying - Means shall be provided to ensure that plug-in modules and PWB'S can only be installed in their designated locations and attitudes in the equipment. Keying shall be positive and easy to use. 2.2.8 Printed Wiring Board Markings - all identification markings on PWB'S shall be oriented such that they are easily and logically readable.
Page 7
2.2.11.4 Finish - Finish of the antenna assemblies and any exterior metal surfaces shall have a finish suitable for all-weather exposure. 2.2.11.5 Obstruction Lighting - The antenna assemblies shall be fitted with obstruction lighting. Provision shall be made to enable removal and repair of the obstruction lights. 2.2.11.6 Toxic Material Warning - Toxic material shall not be used in any location accessible to the technician installing or maintaining the equipment. Warning signs shall be posted within the systems if toxic materials are present, and the equipment manual shall outline the safety precautions to be taken while handling these materials.
Page 8
PART 3 - GENERAL SYSTEM SPECIFICATIONS 3.1 3.1.1 Instrument Landing System System Power Requirements 120/240 V AC 15%, 47-66 Hz, single phase. Shall be of the no-break battery backup design with a charger to provide a minimum of 6 hours operation in the event of an AC line failure. The Charger must restore the batteries to full capability from a 50% discharge condition in 8 hours or less. The batteries are to be of the sealed lead acid design.
3.1.2
Environmental Specifications
3.1.2.1 Ambient Temperature Range Outdoor Equipment: Indoor Equipment: 3.1.2.2 Relative Humidity Outdoor Equipment: Indoor Equipment: 3.1.2.3 Wind 3.1.2.4 Ice: 3.1.2.5 Altitude: 3.1.2.6 Duty Cycle: 3.1.3 to 100% to 95% (non-condensing) To 100 mph (161 km/hr) with 0.5" (12.7 mm) ice Encased in 0.5" (12.7 mm) clear ice To 15,000 ft MSL (4500 m) Continuous 4000 Hours minimum 4000 Hours minimum -50C to +70C -10C to +50C
Mean Time Between Failures (MTBF) as Localizer: calculated by Mil Handbook 217F shall be as follows for the various system Glideslope: components: Mechanical Requirements
3.1.4
To be of a Single-Cabinet design. The cabinet shall be suitable for mounting on the wall of the equipment shelter. Synthesizer, 40-Channel (Standard ILS Channels)
Page 9
3.1.5.5.2 Main to Standby Transmitter Isolation (as 50 dB measured at the antenna outputs) with Standby transmitter operating into a dummy load 3.1.5.5.3 Power Transmitters ratio, Course to Clearance 10 dB nominal as measured on the runway centerline (adjustable)
3.1.5.6 Transmitter Modulation Characteristics 3.1.5.6.1 Modulating Tones 90/150 Hz Navigation 1020 Hz Identification 90 Hz 0.1% 150 Hz 0.1% 1020 Hz 1.0%
3.1.5.6.3 Modulating Tones Total Harmonic Distortion 90 Hz 150 Hz 1020 Hz 3.1.5.6.4 Modulation Depth 90/150 Hz navigation tones Nominal Setting Adjustment Range Identification tone Nominal Setting Adjustment Range
20% nominal for each tone 17 to 23% in 0.1% steps 8% or 10% 0 to 15% in 1% steps
3.1.5.6.5 Modulation balance, 90 Hz/150 Hz Nominal Setting Adjustment Range 3.1.5.6.6 Audio Phase Lock, 90 & 150 Hz Modulating Tones 0.000 DDM 0.030 DDM in 0.001 DDM steps < 5 (Course and Clearance Transmitters)
Page 10
# 5.0% # 5.0%
Shall be programmable through the maintenance terminal Up to four international morse code letters. The normal setting is the letter I followed by a three letter station identifier. Approximately 7 times per minute. A2A using a 1020 HZ Tone
Identification rate Modulation class 3.1.5.6.10.1 Keying Outputs a) Collocated DME (Distance Measuring Equipment)
Means shall be provided for keying a companion DME station which may be co-located with the Localizer station. Every fourth cycle of the identification sequence shall key the DME. The Localizer shall not be keyed during this time. It shall be possible to aurally monitor the Keyed 1020 Hz Identification tone at the equipment or remotely at the Remote Status and Control equipment.
b) Aural Monitoring
Page 11
3.1.5.8 Course Alignment Accuracy at runway threshold 3.1.5.9 Displacement Sensitivity/Course Width
3.1.5.9.2 Clearance transmitter sideband amplitude Shall provide for a smooth transition from the control Course signal to the Clearance signal and for a maximum DDM beyond the normal course sector width. 3.1.5.10 Off Course DDM ( 10 to 35 from the 0.180 (minimum) front course line) 3.1.5.11 Antenna System 14 element, wide aperture LPD (Log Periodic Dipole) dual frequency configuration. 108.00 to 111.975 MHZ Horizontal # 0.005 DDM within a sector bounded by 0.02 DDM on either side of the course line (as measured by an aircraft in a roll attitude of 20 degrees from horizontal). 7 26 dB nominal 50 ohms 1.2:1 maximum Integral
3.1.5.11.4 Vertical Coverage Limit 3.1.5.11.5 Front-to-Back ratio 3.1.5.11.6 Input Impedance 3.1.5.11.7 VSWR 3.1.5.11.8 Monitoring
Page 12
a)
Course Position Alarm (Centerline DDM) (*) CAT I: 0.015 DDM 0.002DDM to 0.020 DDM in 0.001 DDM steps
b) Displacement Sensitivity Alarm (Width DDM) (*). Nominal Alarm Setting Alarm Adjustment Range CAT I: 17% from 0.155 DDM 0.100 DDM to 0.225 DDM in 0.001 DDM steps (For monitor Wide and Narrow alarm limits)
c)
Page 13
e)
f)
g) Reduction in Identification Modulation Percentage (*) Nominal Alarm Setting Alarm Adjustment Range 2% nominal from 8% or 10% modulation 2.5% to 12.5% in 0.1% steps
h)
System shall alarm and immediately shut down in the event of reverse sensing of the navigation information as seen in the far field. An Open or Short in any antenna element, on any antenna element feed or integral monitor pickup cable or within the antenna distribution or monitor combining networks shall initiate an immediate station shutdown. A mechanical misalignment of any of the elements in the antenna array shall be detected an initiate an immediate station shutdown. It shall be possible to bypass this feature through the maintenance terminal.
i)
Cable Fault
j)
Antenna misalignment
Page 14
Nominal Alarm Setting Alarm Adjustment Range 0.002 DDM to 0.020 DDM in 0.001 DDM steps.
b) Displacement Sensitivity Alarm (Width DDM) (*) Nominal Alarm Setting Alarm Adjustment Range CAT I: 17% from 0.155 DDM 0.100 DDM to 0.225 DDM in 0.001 DDM steps (For Monitor Wide and Narrow alarm limits)
c)
d) Change in Carrier Modulation Percentage (SDM) (*) Nominal Alarm Setting Alarm Adjustment Range 4% (nominal) from 40% 30% to 50% in o.1% steps (For Low and High Alarms)
Page 15
f)
g) Reduction in Identification Modulation Percentage (*) Nominal Alarm Setting Alarm Adjustment Range 2% nominal from 8% or 10% modulation 2.5% to 12.5% in 0.1% steps
h) RF Frequency Difference: Course-toClearance Transmitter Nominal Alarm Setting Alarm Adjustment Range 500 Hz (nominal) from 8 kHz 0 to 10,000 Hz in 1 Hz steps
3.1.5.12.3 Maintenance Monitoring Parameters. (*) indicates both Course and Clearance The following Maintenance Monitoring Parameters Transmitters shall be provided as a minimum: a) High CSB Feedline VSWR (*) b) c) d) e) f) g) h) High SBO Feedline VSWR (*) High Transmitter PA Current (*) Reduction in Primary AC Supply voltage Primary DC Voltage Primary DC Current Battery Charge Current On/Off status of a co-located DME
Page 16
3.1.5.12.6 Monitor Memory 3.1.5.12.7 Test Generator Shall provide the following programmable signals for monitor test and certification: 1) a) b) c) d) Course (Centerline) position: Monitor Centering Test: Left Alarm limit for Cert Test: Right Alarm limit for Cert Test: Adjustment Range:
Shall retain at least the last three fault conditions in non-volatile memory.
0.000 DDM 0.001 DDM 0.015 DDM 0.015 DDM 0.000 DDM to 0.020 DDM in 0.001 DDM steps
2) a) b)
Course Width (Displacement Sensitivity) Monitor Width Test: Wide Alarm limit for Cert Test: 155 DDM 0.001 DDM (nominal) 0.129 DDM (-17% from 0.155 DDM nominal ) 0.181 DDM (+17% from 0.155 DDM nominal ) 0.100 DDM to 0.225 DDM in 0.001 DDM steps)
c) e)
Page 17
4) a) b) c)
RF Level: Normal: Low Level alarm limit: Adjustment Range: Corresponds to normal carrier power output 80% (1 dB reduction) from normal carrier output -10 dB to +3 dB
5) a) b) c)
Identification: Normal: Low Modulation alarm limit: Adjustment Range Corresponds to normal identification modulation level 2% reduction nominal from normal level 2.5% to 12.5% modulation 10 sec. Nominal for CAT I systems 0.5 to 20 seconds
3.1.5.12.8 Monitor transfer/shutdown delay times. Adjustment Range 3.1.6 Glideslope System Specifications
3.1.6.1 Frequency Control 3.1.6.1.1 Frequency Range 3.1.6.1.2 Frequency Stability 3.1.6.1.3 Carrier Frequency Separation - Capture Effect Systems 3.1.6.2 Power Output 3.1.6.2.1 Carrier Harmonic Suppression
40-Channel Synthesizer (channel frequency is to be paired with the Localizer) 329.15 - 335.00 MHZ (Standard ILS Channels) 0.0005% 8 kHz As required to achieve the required coverage 60 dB
3.1.6.2.2 Main to Standby Transmitter isolation with 50 dB Standby transmitter operating into dummy load
Page 18
# 5% # 5%
40% nominal for each tone 36 to 44% in 0.1% steps 80% nominal 50 to 90% in 0.1% steps
3.1.6.3.5 Modulation Balance Nominal Setting Adjustment Range 3.1.6.3.6 Audio Phase Lock, 90 & 150 Hz Modulating Tones 3.1.6.3.7 Distortion Products (Demodulated Navigation Tones) a) CSB: 30 Hz 60 Hz 180 Hz 240 Hz 270 Hz 300 Hz 450 Hz With each frequency referenced to 90 Hz or 150 Hz, whichever is the larger signal. b) SBO 90 Hz 150 Hz With each frequency referenced to 60 Hz or 240 Hz whichever is the larger signal.
# 5% # 5%
Page 19
In sectors of 8 in azimuth on each side of the center line of the ILS glide path to a distance of 10 NM up to 1.75 times the glide angle and down to 0.45 times the glide angle above the horizontal, or down to 0.30 times the glide angle as required.
0.0875 DDM at 0.120 0.02 below path, upper and lower sectors symmetrical within 0.070 and 0.14
Provides for full sector path width adjustment from 0.8 to 2.0 Shall be of the broadband, fixed design and provide the following outputs to antenna system: Ant. CSB SBO -6 dB, 0 0 dB, 180 -6 dB, 0 CLR 0 dB, 0 N/A 0 dB, 0
All amplitudes within 0.2 dB All phases within 5 Note: Relative Amplitudes/Phases apply only within columns above 3.1.6.9 Antenna System Capture-Effect array consisting of three identical directional antennas mounted on a self-supporting transmitting tower. Continuously adjustable from 2 to 4 including corresponding antenna offset adjustment in 1" increments (18" max) 10 dBi minimum 16 dB minimum Horizontal Vertical component 26 dB down within 25 of runway centerline 50 Ohms
3.1.6.9.2 Gain 3.1.6.9.3 Front-to-Back Ratio 3.1.6.9.4 Polarization 3.1.6.9.5 Vertical Polarization
Page 20
3.1.6.9.9 Antenna System VSWR 3.1.6.10 System Monitoring 3.1.6.10.1 Monitor Configuration
Integral Standby Transmitter Monitoring Dual Monitors (Selectable AND/OR Configuration) Optional Near Field Path Position Monitor
3.1.6.10.2 Integral Monitoring Parameters a) Change in Path Position (Path DDM) 0.2 deg (0.05 DDM) from 3-degree nominal Glidepath 0.02 to 0.1 DDM in 0.001 DDM steps
b) DDM)
25% from 0.175 DDM (nominal) Monitor Wide and Narrow alarm limits 0.075 DDM to 0.275 DDM in 0.001 DDM steps
c) Carrier Output Power of the Course Transmitter Normal Alarm Setting Alarm Adjustment Range Resolution of Adjustment 80% (-1dB) -10 to +3 dB 0.1 dB
Page 21
e) Change in Carrier Modulation Percentage (SDM), Course Transmitter Normal Alarm Setting Alarm Adjustment Range 4% from 80% (nominal) 70% to 90% in 0.1% steps
f) Change in Clearance Transmitter 150 Hz Modulation Percentage Normal Alarm Setting Alarm Adjustment Range -15% from 80% (nominal) 60% to 95% in 0.1% steps
g) RF Frequency Difference: Course-toClearance Transmitter Normal Alarm Setting Alarm Adjustment Range 500 Hz (nominal) from 8 kHz 0 to 10,000 Hz in 1 Hz steps
Page 22
b)
Change in Displacement Sensitivity (Width DDM) 25% from 0.175 DDM (nominal) Monitor Wide and Narrow alarm limits 0.075 DDM to 0.275 DDM in 0.001 DDM steps
Page 23
d) Carrier Output Power of the Clearance Transmitter Normal Alarm Setting Alarm Adjustment Range -1.25 dB -10 to +3dB in 0.1 dB steps
e) Change in Carrier Modulation Percentage (SDM), Course Transmitter Normal Alarm Setting Alarm Adjustment Range 4% from 80% (nominal) 70% to 90% in 0.1 % steps
f) Change in Clearance Transmitter 150 Hz Modulation Percentage Normal Alarm Setting Alarm Adjustment Range -15% from 80% (nominal) 60% to 95% in 0.1% steps
g) RF Frequency Difference: Course-toClearance Transmitter Normal Alarm Setting Alarm Adjustment Range 500 Hz (nominal) from 8 kHz 0 to 10,000 Hz in 1 Hz steps
Page 24
All Executive and Maintenance Monitoring parameters shall be equipped with a second set of alarm limits which may be adjusted to initiate a maintenance alert when the respective parameter reaches approximately 75% of its normal alarm limit. a) High or Low Shelter Temperature -10C and +40C nominal limits (adjustable) High or Low Outdoor Temperature -10C and +40C nominal limits (adjustable) Fire Alarm Building Security
b)
c) d) 3.1.6.10.8 Monitor Memory 3.1.6.10.9 Test Generator Shall provide the following programmable signals for monitor test and certification:
Shall retain the last three fault conditions on firstin, first-out basis.
Page 25
3) a) b) c) d)
Modulation (SDM): Monitor SDM Test: SDM Low Alarm for Cert Test: SDM High Alarm for Cert Test: Adjustment Range 80.0% (nominal) 76.0% (-4% from nominal) 84.0% (+4% from nominal) Adjustable from 70% to 90% in 0.1% steps
4) a) b) c) c) 5) a) b) c)
Modulation (150 Hz Clearance): Clearance Normal for Generator Test: Clearance Low Alarm for Cert Test: Clearance High Alarm for Cert Test: Adjustment Range RF Level: Normal for Generator Test: Low Level alarm for Cert Test: Adjustment Range Corresponds to normal carrier power output 80% (1dB reduction) from normal carrier output -10 dB to +3 dB 80.0% (nominal) 76.0% (-4% from nominal) 84.0% (+4% from nominal) Adjustable from 70% to 90% in 0.1% steps
Page 26
3.1.7
UNIT
3.1.7.1
Controls
The following controls shall be available as a minimum on the front panel of the equipment and through the Portable Maintenance Data Terminal a) b) c) d) e) f) g) h) j) Main Transmitter Selection Local/Remote Control AC and DC Power Controls for No. 1 and No. 2 transmitters No. 1 and No. 2 Transmitter RF ON/OFF System Reset Lamp Test Integral Monitor Bypass Standby Transmitter Monitor Bypass Wattmeter Channel Select Main transmitter selection No.1/No.2 transmitter RF ON/OFF Equipment transfer No. 1/No.2 System Reset Integral Monitor Bypass Standby Transmitter Monitor Bypass Transmitter and Monitor Control, Parameter Display, Adjustment and Calibration Diagnostics and Self Test
3.1.7.1.2 Control functions available through a) Portable Maintenance Data Terminal (PMDT) b) c) d) e) f) g) h) 3.1.7.2 Front Panel Lamps and Indicators
The following lamps and indicators shall be provided as a minimum on the front panel of the equipment. a) b) c) e) f) g) h) i) j) AC Power indication System Operating on Batteries Main Transmitter Selected (No. 1 or No. 2) No. 1/No. 2 Transmitter OFF No. 1/No. 2 Transmitter ON ANTENNA No. 1/No. 2 Transmitter ON DUMMY LOAD Maintenance Alert Remote Control Fault Integral Monitor No. 1 Normal No. 1 Alarm No. 2 Normal No. 2 Alarm Bypass Standby Transmitter Monitor No. 1 Normal No. 1 Alarm No. 2 Normal No. 2 Alarm Bypass Local/Remote Control
3.1.7.2.1 Lamps
k) l)
Page 27
Localizer Standby Transmitter CSB (Course): SBO (Course): CSB (Clearance): SBO (Clearance): Fwd Pwr Fwd Pwr Fwd Pwr Fwd Pwr
Glideslope System CSB (Course): SBO (Course): CSB (Clearance): Upper Antenna: Middle Antenna: Lower Antenna: Fwd Pwr, Refl Pwr Fwd Pwr, Refl Pwr Fwd Pwr, Refl Pwr Fwd Pwr, Refl Pwr Fwd Pwr, Refl Pwr Fwd Pwr, Refl Pwr
Glideslope Standby Transmitter CSB (Course): SBO (Course): CSB (Clearance): Fwd Pwr Fwd Pwr Fwd Pwr
Page 28
PART 4 REMOTE CONTROL & STATUS UNIT (RCSU) and REMOTE STATUS UNIT (RSU) SPECIFICATIONS 4.1 4.1.1 a) System Power Requirements Primary Power Remote Status & Control Unit (RCSU) 120/240 V AC 15%, 47-66 Hz, single phase 90 to 264 V AC, 47-63 Hz, single phase
b) 4.1.2 a)
Remote Status Unit (RSU) Standby Power (Optional) Remote Control & Status Unit (RCSU)
No-break battery backup system with charger provides 1 hr operation. Charger will restore batteries to full charge in 6 hours. 8.4 V DC no-break battery backup system with charger provides 1 hour operation. Charger will restore batteries to full charge in 24 hours.
b)
4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 217F) 4.3 4.3.1 4.3.2 Size
Environmental Specifications Ambient Temperature Range Relative Humidity Altitude Duty Cycle MTBF (as calculated by MIL Handbook +10C to + 50C 10 to 80% (non-condensing) to 10,000 ft MSL (4500 m) Continuous 20,000 hours minimum
Dimensional Data Remote Status & Control Unit (RCSU) Remote Status Unit (RSU) 195 mm(7.69") Wide x 133 mm (5.22") High x 76 mm (3") Deep including connectors. 0.79 kg (1.75 lb) Remote Status & Control Unit (RCSU) Switches & Indicators Localizer and Glideslope Systems
Page 29
4.4.2.1 Switches
System On/Off System Transfer System Reset Main Transmitter On Standby Transmitter On Off Communications Failure Monitor Normal Monitor Alarm
4.4.2.2 Indicators
4.4.3
DME (When Installed with ILS Localizer or Glideslope) a) b) c) System On/Off System Transfer System Reset
4.4.3.1 Switches
Page 30
4.4.4
VOR/DME Systems (separate co-located facilities installed at the same location as ILS)
4.4.4.1 VOR System 4.4.4.1.1 Switches a) b) c) a) b) c) d) e) f) System On/Off System Transfer System Reset Main Transmitter On Standby Transmitter On Off Communications Failure Monitor Normal Monitor Alarm
4.4.4.1.2 Indicators
4.4.4.2 DME System 4.4.4.2.1 Switches a) b) c) a) b) c) d) e) f) System On/Off System Transfer System Reset Main Transmitter On Standby Transmitter On Off Communications Failure Monitor Normal Monitor Alarm
4.4.4.2.2 Indicators
4.4.5
RCSU Front Panel a) b) Audio Selection - LOC & DME Identification/Communications Alarm Silence On Battery (When optional Battery Backup is installed) Audible Alarm Portable Maintenance Data Terminal (PMDT)
4.4.5.2 Indicators
a) b)
4.4.5.3 Connector
a)
Page 31
4.5.2
Indicators
a) b)
c)
d)
e)
f)
g)
h)
i)
j) k) l) m) n) o)
Runway Selected Display System Operational Status Indicators CAT III CAT II CAT I LOC Only Localizer System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert Glideslope System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert Outer Marker System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert Middle Marker System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert Inner Marker System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert VOR System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert DME System Main On Standby On Main Alarm/Off Standby Alarm/Off Maintenance Alert Auxiliary 1 On/Off Auxiliary 2 On/Off RSU AC Power Ok/On Batteries (when Optional Battery Backup is installed) RSU Communications Failure Audible Alarm Far Field Monitor On/Off & Bypass
Page 32
CAT III CAT II CAT I LOC Only CAT III CAT II CAT I LOC Only CAT III CAT II CAT I LOC Only CAT III CAT II CAT I LOC Only CAT III CAT II CAT I LOC Only CAT III CAT II CAT I LOC Only
Blink Blink On Off Off Blink On Off Off On On Off Off On On OFF Off Off On Off Off Off Off On
FFM detects Localizer course misalignment in e) excess of CAT III tolerance for nominal 2 seconds (adjustable from 1 to 10 seconds)
f) FFM detects Localizer course misalignment in excess of CAT III tolerance for nominal 5 seconds (adjustable from 1 to 120 seconds)
PART 5 - QUALITY REQUIREMENTS 5.1 ISO-9000 5.2 Factory Acceptance Tests The Contractor shall be ISO-9000 certified. The Contractor shall conduct final acceptance tests on the equipment to be delivered. The Purchaser reserves the right to witness the tests. The Contractor shall furnish a copy of the Final Acceptance Test results with the equipment.
Page 33
6.1.1 The general requirements for Bidder supplied documentation are described in the following paragraphs. 6.2 Final Manuals
6.2.1 Manuals shall be divided into logical sections which contain installation instructions, operating instructions, alignment and adjustment procedures, detailed theory of operation (in particular pertaining to the interactions of the sub-assemblies and modules and associated interfaces as part of the total system), maintenance routines, fault finding and troubleshooting procedures, detailed parts lists and drawings. Associated software and hardware descriptions, in particular as they relate to system operation, shall be included. The contents shall be sufficiently detailed to enable the Citys technical personnel to understand clearly how the system functions and to be able to trace and measure signals throughout the system down to the PWB/module level. Schematics and diagrams shall be of a quality to enable clear and unambiguous comprehension. PART 7 - TRAINING REQUIREMENTS 7.1.1 The Bidder shall provide a price for the presentation of a course of instruction for installation and maintenance personnel. Details of the course including subjects, length, student requirements, and materials furnished, etc. shall be provided with the proposal. 7.2 The technical training shall cover in detail, the theory, operation, test and alignment procedures and fault recognition techniques relevant to the ILS equipment. Preventive maintenance procedures (where applicable) shall be covered, however, more emphasis is to be placed on alignment and operating procedures, fault finding and techniques for efficient and expeditious repair of equipment failures. Emphasis shall be placed on understanding of system hardware and software by means of block diagrams, logic diagrams, state diagrams, flow charts, signal identifications, memory maps, etc. The ratio of practical sessions to the amount of classroom theory should be as large as practicable, recognizing the total time available for training. 7.3 Course Scheduling - It is intended that the first maintenance training course on the ILS system will be completed prior to the shipment of the first system. 7.4 Course Presentation - In drawing up the syllabus, the Bidder shall schedule no more than six hours of formal classroom instruction in any one day. Classroom practical training together shall not exceed seven hours in any one day. 7.5 Reports on Training - An examination shall be held at a suitable interval during, and at the end of each training course to monitor the progress of each trainee and to check on the effectiveness of the instructional method. Following each course, the Bidder shall report on the performance of each trainee. During each course, should a trainee experience such difficulty as to warrant withdrawal from the course, the contractor shall immediately advise the City. 7.6 Bidders Personnel - The Bidders shall provide a suitable number of competent and qualified instructors fully capable of providing the required training to a high standard. The City reserves the right to examine the background, training and experience of the Bidders instructors in order to assess their competency and decide on their acceptability.
Page 34
7.7 Citys Personnel - Candidates for training may be either Electrical Engineers or Electrical Technicians as well as any other City personnel associated with airport operations. The academic requirements for the electrical classifications are: Electrical Engineers: A recognized degree in Electrical Engineering
Electronics Technicians:Two year post-secondary school training in electronics plus some years of experience in maintenance or installation of electronic equipment. 7.8 Materials To Be Provided By The Bidder - The following materials shall be supplied by the Bidder: 7.8.1 A detailed list of course objectives, based on the ILS system maintenance philosophy and stated in terms of what the student will be able to do on completion of the course. The submission of course objectives shall also contain a statement of how student achievement of the course objectives will be measured. 7.8.2 Classroom and laboratory facilities, which will provide suitable environments for good teaching practices. 7.8.3 One copy each of the equipment hardware and software manuals for each student as part of handout material. These manuals will be retained by the student. PART 8 WARRANTY AND MAINTENANCE SERVICE 8.1 Bidders are to list the items covered under warranty and under what circumstances the warranty covers as well as state the time period of the warranty. 8.1.2 Bidders are to advise what type of Maintenance Services they can provide for the ILS System once the system is operational. Please indicate the cost per year for each type of service and the length of term desired. Example 1 year, 3 year, 5 year, etc.
Page 35