Anda di halaman 1dari 120

Q a tm A tmain- 1V le d e R s l r u nu uo t o # au A d d e el e

I- o s , nn &O -i Ta i nH u e O le i nSt rin e ng O -i Po u t e n t t n nSt rd c D mo s ai s e ro 2 H u E re c S p ot 4 o r meg n y u p r L c le h i l u p r o a T c n a S p ot c We t o s Iv noy s C a tn e tr Po u t in rd c Kt g t i Maei U a eR p r U o R q e t tr l s g e ot p n e u s a s V n o P r r n eMer s v ib e d r ef ma c o tc A aa l i l e S mePi a A tmai Drc a r e s uo t n i t c o e

www. a tmA t ma inc m |1. 4 80 Qu n u uo t . o o 74 5. 0 8 0

CLICK PLCs
Section 1

In this interactive PDF you can:

Programmable Controllers

DL05/06 PLC
Section 2

Use bookmarks to navigate by product category Use bookmarks to save, search, print or e-mail the catalog section Click on part #s to link directly to our online store for current pricing, specs, stocking information and more

DL105 PLC
Section 3

DL205 PLC
Section 4

DL305 PLC
Section 5

DL405 PLC
Section 6

Productivity3000
Section 7

Volume 13

e7-1

Some call it a PAC.


Whats a PAC?

Advanced control from AutomationDirect


Some call it a PLC.

A programmable automation controller* (PAC) is a compact controller that combines the features and capabilities of a PC-based control system with that of a typical programmable logic controller (PLC). PLC Feel

We call it ...

Modular footprint Industrial reliability Wide array of I/O modules and system configurations PC Power Large memory and high-speed processing High-level data handling and enterprise connectivity Extensive communications capability, multiple protocols and field networks PACs are most often used for advanced machine control, process control, data acquisition and equipment monitoring. With Productivity3000, you can get all the power you need for advanced applications. The great thing is, even if you dont need every bell and whistle, you still get an easy-to-use, super-flexible machine that costs less than most traditional PLCs.

Visit www.productivity3000.com for complete details and FREE software download

Do these with ease


Large I/O Count Data Collection/ Exchange Networked Communications Multiple HMI

Who wouldnt want a controller with seven built-in communication ports, easy local and remote I/O connection, USB or Ethernet programming and an integrated LCD display - and thats just the CPU!

Integrated Drive Control

Process Control

Volume 13

e7-2

Programmable Controllers

1 - 80 0 - 633 - 0405

Its our job to make you more productive


More Productive
With Productivity3000, were giving you advanced PAC features in a rugged PLC frame at a fraction of the cost compared to similarly equipped competitive products. Expansive communications capability built into the CPU is standard. The FREE (for a limited time, $495 value) full-featured Productivity Suite software lets you take a test drive before you buy, plus no licenses to register, track or transfer.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors

when specifying

More Productive
Its pretty simple - install the CPU in a rack, add local and/or remote I/O, even GS drives. Theres no power budget to calculate or other restrictions - install any module in any base. Local and remote I/O ports are built into the CPU, as well as Ethernet and serial ports for device and network communications.

when configuring

Practical prices

Once youve connected the components, let the system autodiscover the hardware configuration and save it in your project. Modules are then electronically keyed to prevent incorrect replacement.

More Productive
Programming and commissioning a system with any type of automation controller is time consuming and can be a large part of your overhead. Weve created powerful processes in the programming environment to reduce your development time.

when programming

Simpler means fewer mistakes

Timesavers include combined ladder logic and function block programming; tag name database for easier documentation; task management that minimizes scan time; advanced instructions that simplify complex tasks, and an exhaustive HELP file that covers both hardware and software topics.

More Productive

Run-time editing, hot-swappable I/O modules and onboard program documentation are tools that help you commission and troubleshoot your system more quickly and conveniently. Use the built-in LCD display on the CPU and Remote Slave modules for system diagnostics, configuration and troubleshooting.

when troubleshooting

Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Time is Money

Advanced Diagnostics

The patent-pending LCD interface built into each analog module allows you to view field signal levels without the hassle of an external meter.

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-3

PAC features at a PLC price!


High-performance CPU with 50Mb memory, fast scan time Modular rack-based footprint with 36 discrete and analog I/O option modules, up to 115K+ I/O Unmatched built-in communications capabilities, including local and remote I/O ports and networking Integrated GS drive communications over Ethernet LCD on CPU and Remote Slave for diagnostics Patent-pending LCD on ALL analog modules - helpful in troubleshooting and reading process values Hot-swappable I/O No module placement restrictions any module in any slot, any base No power budget limitations Optional I/O terminal blocks or easy ZIPLink plug-and-play wiring

TOP 10 Hardware Highlights

and a two-year warranty to boot!

CPU just $599, with 7 communication ports

LCD aids troubleshooting

The 50Mb of memory and fast scan time is just for starters - this CPU does the work of at least four or five pieces of hardware compared to other controllers. With its seven built-in communication ports, it does the usual CPU stuff like storing and running the program, plus Plug-and-play USB programming (uses standard A-B cable) Tag database and program documentation storage in CPU (Program pre-loaded on PC not necessary) USB local I/O expansion (no local I/O expansion master module needed) Ethernet remote I/O expansion (no Ethernet remote master module needed) High-speed Ethernet port for HMI and peer-to-peer or business system networking (no Ethernet communications module needed) Two serial ports for peripheral device interface or controller networking (no serial port module or ASCII module needed) USB data logging right from the CPU
Volume 13

USB Programming Port

Ethernet Network Port Ethernet remote I/O

The built-in display can show system alarms and information, or it can be configured to display user-defined messages with instructions triggered by the program.

USB Data port

One RS232 and one RS485 serial port both support Modbus or ASCII protocols to connect to other controllers or peripherals.

Serial ports for master/slave or custom device connections

USB local I/O expansion

Connect up to four additional I/O bases from the USB local expansion port.

e7-4

Programmable Controllers

1 - 80 0 - 633 - 0405

We used technology to simplify your job


Field access with display on analog modules
The patent-pending LCD on all analog modules gives you quick and easy access to field signal values - no need to drag out a multimeter or other measurement tool. Module and signal faults are also shown.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders

To make I/O wiring fast and easy, use our ZIPLink cables and connector modules.

Over 35 I/O modules capture and control a wide range of field signals. Up to 64-point DC I/O Up to 16-point AC I/O, isolated or non-isolated Up to 16-point analog I/O; voltage, current or temperature I/O modules can be placed in any slot, in any base - no need to remember special restrictions or calculate power budgets. And for critical systems, the hot-swap feature can save you from a downtime or worse.

Plenty of discrete and analog I/O modules

The convenient USB port on the Remote Slave module lets you program and monitor from any remote I/O location; plus two serial ports support Modbus or ASCII devices.

Connect up to 32 remote base groups from the Ethernet remote expansion port. Each remote group supports up to four additional local bases. You could end up with over 115,000 I/O!

Ethernet remote I/O like youve never seen

Easy drive integration

Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix

Drive-intensive applications are a snap with this remote I/O network. Connect up to 64 AutomationDirect GS series AC drives on the Ethernet remote I/O network (using GS-EDRV option cards). Units are auto-discovered when configuration update is requested - its that easy.

Compatible with Connection Systems

Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-5

Full-featured FREE Software


Auto set-up and discovery of hardware Tag name database programming Task management Advanced fill-in-the-blank instructions Seamless corporate database connectivity Graphical HTML-based Help File Run-time editing Project file and user documentation stored in CPU USB data logging on the CPU Tag database export to C-more HMI

TOP 10 Software Highlights

The Productivity3000 is a brand-new controller, and we want everyone to see just how feature-packed it is and how productive it can make you. Thats why were offering the software for FREE (downloadable online) for a limited time - check out the tools, instruction set and programming/debug environment that will let you configure and program a system in less time than you can imagine.

Full-featured Productivity Suite software FREE ($495 value)

Hardware auto-discovery

all in an intuitive Windows-based programming environment

Task management boosts program speed and efficiency

WIth the ample memory in the CPU, theres plenty of room for the program, tag name database and all the program documentation. This means the helpful descriptions and comments are available to anybody with a PC and Productivity Suite software. This can be pretty important when its 1 a.m., the machine is down and youre the one that has to look at the program and figure out whats wrong.

All project files in CPU means its not all Greek to you

One click is all it takes to detect and auto-configure the hardware connected to the system, including local and remote bases and I/O. GS drives on the internal Ethernet network are also discovered during any configuration update. This can save you literally hours and hours of setup time. Or, configure the system offline by dragging and dropping bases and modules.

There are so many time-saving instructions, and they all have one thing in common - their fill-in-theblank approach makes it easy to configure even the more complex tasks that previously required a whole bunch of program code. Scaling, calculator-style math, statistics, send email, it goes on and on ...

Advanced instructions are timesavers

The Task Manager helps organize program code and execute it for maximum speed and efficiency. Create functional tasks, name them and schedule their execution frequency - every scan, every second, or when called. A First Scan only task lets you initialize values and conditions. Store specialized tasks that help debug and troubleshoot in the Disabled Tasks section. Programmable Controllers

Volume 13

e7-6

1 - 80 0 - 633 - 0405

Saves you time from start to finish


Also, a tag name database means no more confusing and ambiguous memory and I/O references - add descriptive names as you program or enter all the tags before you even write one line of code. The data is stored in true database format so you can search, filter and sort; import a .csv file or use the one created every time you save the project for importing into other databases. Data memory ranges in the Productivity3000 are not fixed by data type, which is more efficient because you have the freedom to define the data types you need instead of having wasted memory for ones you do not.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

Tag name database is friendly and flexible

Easy data logging on CPU

Help File really does help

Easily log data to a removable mass storage device (USB) on an event or time basis. Track up to 64 data values and system errors through the Data Logger tool. The CPU will hold the data internally until an external device is replaced.

Detailed hardware and software information is at your fingertips with the exhaustive HTML-based Help file. From Getting Started to detailed program instruction descriptions, its all there when you need it. Find the help you need on a specific topic quickly, and read only whats relevant to you at the time.

Run-time editing

Commissioning or troubleshooting a system can be less time-consuming if you can make program edits on the fly. Download edits to the CPU without pausing I/O updates or stopping/restarting the program. From melting rubber to making paper, you can keep your process running, avoiding downtime and product waste.

With the integrated DataWorx instruction, connectivity to Microsoft Access, SQL or ODBC databases has never been easier (DataWorx P3K server for PC sold separately). The controller can retrieve, add, delete and update data records in the remote database.

Seamless corporate database connectivity

C-more HMI software has a direct import feature for the Productivity3000 tag database. No duplicating work - bring in all the tag names from the controller program right into C-mores database with just a few keystrokes.

Import tags into C-more database

Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-7

Lets Start with the Basics ...


Now you have the freedom to define your application tags with no limits or fixed boundaries for timers, counters, integer words or any other data type. With Tag name based programming, there are no specific pre-defined memory ranges, only data types; you define the elements specifically for your project. This is much more efficient because you define the data types you need and have no wasted memory for unused, fixed ranges.

Tag name Based Programming

In addition, the Productivity3000 offers the ability to descriptively identify the tags in your program. Older, fixed memory controllers force the use of pre-defined nomenclature for the data types; for example, if you were creating a timer to be used as an oven purge cycle you had to use a timer such as T4:01, and use the corresponding words and bits for the timer preset and status bits. Now you can create a descriptive tag name: Oven1 Purge Timer.Pre and identify it as a numeric tag for your preset, and create a similar tag name: Oven1 Purge Timer.Dn and identify it as a boolean tag for your status bit. These are just examples; you can pick any naming scheme and tagnames that you wish. Sort tag data by any column, ascending or descending. Filter by data types or by specific text. Many people create detailed process flow charts before they begin programming. This true database format allows you to create the tag database based on your process flow charts and then import it directly into your Productivity3000 project. For added convenience, a .csv file can becreated every time you save your project. Use it for import into other tagname-based devices, like our C-more HMI.

Fully Customizable

True Database Format

By default, the Tagname database populates all necessary tag options for each data type including retentive value requirements, forceable options and even accessibility for external Modbus devices. As you settle into your project creation, you will determine the fields that you use most often. You can easily re-arrange or hide columns to suit your needs or click the Reset Table button to return to the factory defaults.

Still need more? Add up to 32 Remote Slave racks, each with its own set of four local expansion racks and the number is truly staggering - well over 100,000 I/O points.

Start with high-density I/O modules - up to 64 inputs or outputs per module, install those in an 11- slot base, and you've got over 700 I/O in a single rack! Add up to 4 local racks to your local base group, and the possible I/O total grows to over 3,500 I/O points.

Huge I/O Capacity

Add up to 32 Remote Base Groups!

Have you ever felt unproductive configuring stop bits, parity, or baud rates in order to connect to a programmable controller? The Productivity3000 uses USB programming for true plug-and-play functionality. Plug in your USB cable and move on to more productive activities like configuration and programming.

Plug-and-Play Programming

Volume 13

e7-8

Programmable Controllers

1 - 80 0 - 633 - 0405

Tremendous Processing Power


Sub-millisecond Scan Times Powerful and Efficient

... Power AND Grace!

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

The P3-550 CPUs lightning fast processor executes your ladder code quickly and efficiently! The performance benchmark used for testing the Productivity3000 includes 3 kbytes of Boolean logic, and 1k of I/O. The Productivity3000 P3-550 CPU consistently executes this test with a scan time of less than 650 microseconds. This processing power also means that there are practically no limits on the number of timers, counters, and PID loops for your application. And the powerful task management tools built in to the software help you streamline your ladder code for maximum efficiency.

Generous 50 Mb of Memory

Plenty of storage for your program AND...

Documentation Stored On-board

Store your entire project with ALL documentation in the CPU, and never hunt for that old laptop again. You know, the only one that has the updated code from last year when you made all those changes. Sure, we recommend that you keep a backup of all your code and documentation, but who hasnt been burned by this classic PLC problem?

Place Any Module in Any Slot

You can install any I/O module in any I/O slot of any base in a Productivity3000 system with no restrictions. The only fixed positions are shown in the figure below; a power supply must be in the power supply slot, and one of the three controllers must go in the CPU slot. Other than this, there are no special slots or rules governing placement of your discrete, analog, or specialty I/O modules. Both the AC and the DC power supply are powerful enough to power any combination of I/O modules in any size base. You can program across Ethernet as well, but we wanted Productivity3000 to have a fast reliable way to get started. When combined with autodiscovery of I/O modules, the USB plug-and-play capability helps you be productive right away.

No power budgeting required!

Save time and avoid long start-up operations or other down-time related inconveniences. All Productivity3000 I/O modules support hot-swap.

Hot Swap I/O Modules

Once you have determined the desired placement of the I/O modules in your Productivity3000 system, you can enable electronic keying to prevent inadvertent rearrangement or improper replacement of any I/O module.

Electronic Keying

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-9

Work Smarter ...


There are so many time-saving instructions, and they all have one thing in common - their "fill-in-the-blank" approach makes it easy to configure even the more complex tasks that used to require a whole bunch of program code. Scaling, calculator-style math, statistics, send email, it goes on and on.

Application Specific Instructions

Consider these two frequent ladder logic headaches finding an average value from a dynamic tag value or its min./max. values. With Productivity3000, you just fill in the blanks. How productive is that!

In this non-linear scaling example, the volume of a cylindrical tank needs to be determined based on an ultrasonic sensor signal.

Affordable ZIPLinks Save Hours of Wiring

We strongly recommend the use of ZIPLink cables and wiring modules, which eliminate the need for hand wiring of I/O modules to DIN rail terminals. In fact, many of the Productivity3000 I/O modules do not include the terminal block for direct connection of I/O. In particular, the high-density (32-point and 64-point) modules require the use of the ZIPLink cables (there simply isnt enough room on the front of these module to terminate that many I/O points).

With the SCLN instruction it's a simple matter to enter a few pairs of values, and the Productivity3000 interpolates between the points!

Choose a ZIPLink module and cable...

...or a ZIPLink pigtail

Volume 13

e7-10

Programmable Controllers

1 - 80 0 - 633 - 0405

... with these Intelligent Strategies


Advanced Diagnostics
All Productivity3000 analog modules have a four-line LCD on the front panel which provides a quick and easy way to troubleshoot many problems without needing a meter or a programming PC. Just as you can quickly check the front panel of a discrete module to determine the state of an I/O point, now you can check the status of your analog signals just as easily. The LCD allows non-invasive measurements; no need to connect a multimeter in line with the analog signal (which might even affect the signal being measured). View the signal in volts or milliamps (depending on the module) or view the resulting tag value - i.e. 0-65535 (Decimal or Hex) that is being processed by the PAC.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection

Patent Pending LCD on all Analog Modules!

Non-Invasive Measurements

LCD on CPU aids troubleshooting


The built-in display on the CPU can show system alarms and information, or it can be configured to display userdefined messages with instructions triggered by the program.

Software Configurable I/O Modules

Most of the analog I/O modules allow software configuration - no dip switches to set! Just pull up the hardware configuration dialog box, and select your range, resolution, etc. right on the screen.

Module Status Bits (MST) are automatically created for each module when you select (or auto-discover) that module in your hardware configuration. These bits are added to your tagname database and you can change or augment the tagnames to be even more descriptive. Use these MST bits for error checking and reporting, and to simplify the troubleshooting process.
Volume 13

Module Status Bits

Enclosures Tools Pneumatics Appendix Product Index Part # Index

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-11

Create custom Data View windows to organize and access the exact tag values that matter for various troubleshooting and debugging tasks. Edit values, force bits, and check Modbus addresses. You can even choose to view the native tag values, or have the Data View window convert to more convenient formats: hex, binary, BCD, etc. Then give your Data View windows their own descriptive names and save them for future sessions.

Analysis Tools put you in Control

Organize, Analyze and Log Data

Bit and Word Histograms

Create powerful real-time graphs with the Bit Histogram and Word Histogram tools and see your data like never before. Isolate chase conditions, visualize intricate processes, or make sense of rapidly changing numbers. Select a specific sample rate, and trigger the plots manually or based on a specific trigger tag.

The Productivity3000 accepts the SanDisk USB "Pen Drive" and offers this easy-to-configure Data Logger dialog box shown at left. USB drives can be used to log system errors or any type of controller data. Capture data periodically or when certain events occur.

Data Logging

USB drives can also be used to upload or download a project to/from a Productivity3000 without having a PC present. This feature is great for updating remotely located PACs - just send your project on a USB drive to any factory in the world, and the controller can be updated with the most current files.

SDCZ4-2048-A10

Volume 13

e7-12

Programmable Controllers

1 - 80 0 - 633 - 0405

Enterprise Connectivity
Connect and pass data to all the common database formats: MS Access, ODBC, and SQL Server. Productivity3000 was designed with database connectivity in mind. The DataWorx Request (DWX) instruction helps you define all aspects of the connection to a DataWorx server, and even allows tags to be assigned for In Progress, Complete, Success, Error, Timeout, and more. Define your own mapping table, 'where' table, and SQL View, and configure automatic polling with custom polling periods. The Productivity Suite Software comes with a trial version of DataWorx P3K (the software that runs on your server), so you can experiment with and test your database application with no risk (this trial version is fully functional, but the server will disconnect after 30 minutes).

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters

Built-in Database Connectivity

Free Trial of DataWorx P3K

Stride Industrial Ethernet Switch

Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors

Single License: $595.00 (PC-DATP3K-1)

Allows a single Productivity3000 PAC to retrieve, add, delete and update data records in a standard database. Allows an unlimited number of Productivity3000 PACs to retrieve, add, delete and update data records in a standard database.
From: myPAC@myFactory.com Sent: Thursday, January 21, 2010 4:30 PM To: Maintenance Foreman Subject: Oven 2 is over-temp

Unlimited License: $1,595.00 (PC-DATP3K-UN)

Setpoint is: 450 degrees Date: 1/21/2010

Actual temp is: 524 degrees

Time: 16:29:03

If your Productivity3000 is on a network with an SMTP server, it can send e-mails right from your ladder logic. Embed tag data for even more informative messaging. A dedicated instruction makes it simple.

Built-in E-mail Capability

Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures

The Remote slave module installs in the CPU slot of the first base in each remote base group. It includes two serial communication ports (both supporting Modbus RTU Master/Slave and ASCII In/Out up to 115.2K baud rate): one (1) RS-232 port and one (1) RS-485 port. So each of your remote base groups can connect to additional serial devices. You can even program your P3550 CPU from the USB port on any remote slave; just plug in a USB cable and be productive - even in a remote location!

Remote Slave Connectivity Options

Main Control System

Remote Location

Tools Pneumatics Appendix Product Index Part # Index

Even Supports Remote Programming USB Plug and Play


Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-13

The P3-550 CPU has seven ports available to handle most of your communication needs. You shouldn't have to pay extra or take up valuable slots for each communication port required to solve your application. From plug-and-play programming to database connectivity, the Productivity3000 is designed to meet all your communication needs.

Seven Ports on the P3-550 CPU

Incredible Communications Capabilities ...

Two Ethernet Ports

The P3-550 CPU has two built in Ethernet ports. One connects to Remote Slave I/O racks (up to 32) and up to 64 variable frequency drives. The other can connect the CPU to HMIs, other controllers, and to your factory network.

CPU programming and monitoring including: Real-time data view Error history monitoring Task management Security account management PAC configuration Ladder logic editing

Ethernet capabilities include: Database/enterprise connectivity Sending e-mail Connecting to other factory devices
Database

Remote data monitoring

Email Internet Local data monitoring Programming laptop SMTP Gateway LAN Server running DataWorx

DL205 C-more HMI Bar code reader

Message board

Two Serial Ports

ASCII Communications

The P3-550 CPU has two serial ports built-in: One (1) RS-232 (RJ12) One (1) RS-485 ( 3-wire terminal block)

Both ports support: Modbus RTU Master connections Modbus RTU Slave connections ASCII incoming and outgoing communications Custom Protocol incoming and outgoing communications

Use ASCII communications instructions to send and receive nonsequenced String data via a serial port. ASCII communications are typically used for receiving bar code strings from a scanner or sending statistical data to a terminal or serial printer.

Write your own protocol if needed

Send and receive non-sequenced byte arrays with the custom protocol capability. This function is typically used for communicating with devices that don't support the Modbus protocol but do support some other serial protocol.

Volume 13

e7-14

Programmable Controllers

1 - 80 0 - 633 - 0405

... All Built in to the CPU!

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors

Connecting your Productivity3000 to variable frequency drives couldn't be easier! Connect up to 64 of our GS1, GS2, or Durapulse (GS3) drives via Ethernet (using our GS-EDRV modules), and the Productivity3000 will automatically detect them. The auto-discovery process eliminates the configuration headaches - your drives are ready to program in just a few minutes. After the auto-discovery process, the dedicated instructions "GS Drives Read" and "GS Drives Write" will prompt the programmer with all the available parameters (in both "run mode" and "stop mode") that can be configured for each model of drive - then it's a cinch to fill in the blanks and program your drives!

Connect up to 64 VFDs

Perfect Match for Our C-More HMI

Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Export your tagname database from the Productivity3000 and import it into C-more software to jumpstart your HMI development. No more digging through your notes, or hunting through your ladder logic to find the right tagname.

Specific instruction designed for database communication

The DataWorx P3K data logging software provides an easy and inexpensive way to collect data from the Productivity3000 controller by connecting it to enterprise database systems powered by Microsoft Access, SQL or ODBC compatible servers. Report-by-exception operation eases network traffic by sending information only when needed. The data logging software starts at $595.00 for a single controller connection.

Easy data logging

The DataWorx Request (DWX) instruction lets you define all aspects of the connection to a DataWorx server (software sold separately), and even allows tags to be assigned for In Progress, Complete, Success, Error, Timeout, and more. Define your own mapping table, 'where' table, and SQL View, and configure automatic polling with custom polling periods.

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-15

From Configuration to Debug - access all your tools quickly and easily

Application Tools at your fingertips

Productivity Suite Software...

Windows look & feel

Comprehensive

All panes & toolbars can be undocked, tabbed, and relocated to optimize your workflow

Combined ladder & fun

The Task Management pane allows quick and easy prioritization of your Ladder Logic code. Break your code into logical tasks, and then use the task manager to easily change the priorities, or even disable parts of your code.
Volume 13

Task Manager for organizing your code

Create (and save) multip

e7-16

Programmable Controllers

1 - 80 0 - 633 - 0405

...enables fast and efficient development


Help Files Run-time Edits & Project Transfers

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Drag and Drop Instructions...

...then simply fill in the blanks, for super-productive development

ction block programming

ple data view windows for easy debugging

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-17

Change of Value (CHG) Instruction

Productive Instructions ...


Ramp Generator (GEN) Instruction
Increase or Decrease the value of an Output at a defined rate.

Read two consecutive Values from a Tag at a predetermined Sample Rate and Output the Amount of Change.

Find Min/Max Values (MIMX) Instruction

Store the Lowest and Highest Values of a Numerical Tag.

Selected Summation (SUM) Instruction


Sum the values for up to eight Selected Inputs.

Send an Email to up to four Email recipients via the P3-550 Ethernet port. Note: requires an SMTP server on the local network. Use in conjunction with the Pack String Instruction to combine predefined text with tag data for informative messages.

Send Email (EMAL) Instruction

Pack String (PKS) Instruction

Combine data from two or more Numeric, Boolean, or String Tags into one common String Tag.

Alarm (ALM) Instruction

Monitor an Input Value and enable Alarm Bit Outputs based on predefined Setpoints.

Volume 13

e7-18

Programmable Controllers

1 - 80 0 - 633 - 0405

... Here are Just a Few!

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Nimble Math Editor (MATH) Instruction

The Productivity Suite makes mathematical operations a cinch. Simply type your formula into the formula box area, or use the calculator style keypad to enter equations. Insert tagnames wherever they are needed, and make sure to enter a tagname for the result. You can type the tagnames or use the tagname chooser to look up a specific tag and insert it. How much more productive could this make you?

In addition to the Math Instruction, Productivity Suite offers the Data Statistics instruction for calculating sums, averages, or median values or for determining the Min. or Max. value from a group of tags.

Data Statistics (DATA) Instruction

PID is used for precise control of a process or system by monitoring a process variable and dynamically varying an output to achieve a desired set point. The Productivity3000 offers advanced PID, a cascade mode for handling a second (minor) PID loop, and fillin-the-blank simplicity for a wide range of parameters and alarm values.

Advanced PID Loop (PID) Instruction

Need to secure your Productivity3000? Enable the two security options, and create the desired user accounts. You can allow users to read the project and monitor data only, and/or allow them to transfer projects into the PAC (make changes). Manage the user accounts independently, or quickly turn the security levels on and off globally for all users.

Multi-Level Security Options

We dont have room to show you all the time-saving instructions, so please download the software and see for yourself! Thats right, for a limited time were offering the Productivity Suite software as a free download from our Web site. Give it a try and see all the great instructions, the intuitive user interface, and the extensive help files. Remember, just click the Help button on any instruction for a detailed description of that instruction.
Volume 13

And theres so much more...

Free Download for a limited time!

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-19

AutomationDirect HQ and mega-warehouse, just north of Atlanta, GA USA

Keep it simple, pass along the value.


We were originally founded as PLCDirect in 1994 and have grown from a tiny PLC company to one of the best value choices in the industry.

Saving you money every day since 1994 . . .

In 1999, we changed our name to AutomationDirect.com, and brought that pass along the value philosophy online. We have been serving tens of thousands of satisfied customers ever since. Whether the economy is up or down, we are prepared to serve our customers efficiently, with better service and value than traditional suppliers.

As the first industrial controls company to successfully use a telephone supported direct sales catalog for PLC products, we learned that the way its always been done approach is not necessarily the most efficient way. So we worked smarter to develop in-house processes that maximized productivity to keep costs low. Then we passed those savings on to our customers.

And weve been voted tops in service by several other independent industry sources as well.

OEMs spoke, and they spoke our name ten years in a row! The Reader s Choice survey hosted by Control Design magazine aims to identify the best products and service in the industry. Results for every year going back to 2001 indicate we consistently provide top-notch support to our customers in several product categories.

. . . and always #1 rated service for FREE

1-800-633-0405

www.automationdirect.com

Productivity3000 Overview
Bases
Four bases are available, with 3, 5, 8, and 11 slots.

Company Information Systems Overview Programmable Controllers

Productivity3000 Bases
Part Number P3-03B P3-05B P3-08B P3-11B Description
3-slot base 5-slot base 8-slot base 11-slot base

Price
<---> <---> <---> <--->

Field I/O Software C-more & other HMI Drives Soft Starters

Power Supplies

Productivity3000 Power Supplies


Part Number Description Power supply (powered from AC source) P3-01AC Power supply (powered from DC source) P3-01DC Price
<---> <--->

Two power supplies are available; one accepts AC input and one accepts DC input.

Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders

P3-01AC

CPU Module

One CPU module is currently available.

Productivity3000 CPU Module


Part Number P3-550 Description
CPU module

Current Sensors

Price
<--->

Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring

UNLOCK

Expansion and Remote Slave Modules

P3000 Expansion, Remote Slave Modules


P3-EX
P3-RS REMOTE SLAVE
CPU
UNLOCK UNLOCK UNLOCK

Power Circuit Protection Enclosures Tools

One local expansion module and one remote slave module are available.

Local Expansion Module

Part Number P3-EX P3-RS

Description
Expansion module Remote slave module

Price
<---> <--->

EX
UNLOCK UNLOCK UNLOCK

RUN ERR

REMOTE I/O

LNK

Pneumatics Appendix Product Index

EXP I/O IN

SLAVE ADDRESS X1 X10

P3-EX Expansion Module

EXP I/O OUT

PWR

UNLOCK

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

23

EXP I/O OUT

456

78

23

LNK

456

78

901 901

P3-RS Remote Slave Module


Volume 13

Part # Index

Programmable Controllers

e7-21

Productivity3000 Overview
Discrete I/O Modules
Seven discrete input and thirteen discrete output modules are available.

Discrete Input Modules


Part Number P3-16SIM P3-08ND3S P3-16ND3 P3-32ND3 P3-64ND3 P3-08NAS P3-16NA Description
Input Simulator Isolated Sinking /Sourcing Input Sinking/Sourcing DC Input Sinking/Sourcing Input Sinking/SourcingInp ut Isolated AC Input AC input

Discrete Output Modules


Part Number P3-08TD1S P3-08TD2S P3-16TD1 P3-16TD2 P3-32TD1 P3-32TD2 P3-64TD1 P3-64TD2 P3-08TAS P3-16TA P3-08TRS P3-08TRS-1 P3-16TR Description
Isolated Sinking Output Isolated Sourcing Output Sinking Output Sourcing Output Sinking Output Sourcing Output Sinking Output Sourcing Output Isolated AC Out AC Output Isolated Relay Output Isolated Relay Output Relay Output

Price
<---> <---> <---> <---> <---> <---> <--->

Price
<---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <--->

Six analog input, seven analog output, and two analog input/output modules are available.

Analog I/O Modules

Analog Input Modules


Part Number P3-04ADS P3-08AD P3-16AD-1 P3-16AD-2 P3-08RTD P3-08THM Description
Isolated Analog Input Analog Input Analog Current Input Analog Voltage Input Analog RTD Input Analog Thermocouple

Analog Output Modules


Price
<---> <---> <---> <---> <---> <--->

Part Number P3-04DA P3-08DA-1 P3-08DA-2 P3-06DAS-1 P3-06DAS-2 P3-16DA-1 P3-16DA-2

Description
Analog Output Analog Current Output Analog Voltage Output Isolated Analog Current Output Isolated Analog Voltage Output Analog Current Output Analog Voltage Output

Price
<---> <---> <---> <---> <---> <---> <--->

Analog Input/Output Modules


Part Number P3-8AD4DA-1 P3-8AD4DA-2 Description
Analog Input/Output Analog Input/Output

Price
<---> <--->

Volume 13

e7-22

Programmable Controllers

1 - 80 0 - 633 - 0405

Productivity3000 Overview
Of course, what youll need for your system depends on your particular application, but this overview shows you what youll need for a simple system.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches

What youll need:

1.

Select your base.

2.

Select a 24 VDC or 120 VAC power supply.


P3-01AC

3.

Order a P3-550 CPU module.

4.

Order and install the Productivity Suite programming software in your PC.

UNLOCK

Encoders Current Sensors Pressure Sensors Temperature Sensors

5.

At the same time, select and order your ZIPLink wiring system or removable terminal blocks.

Select and order your I/O modules.

Pushbuttons/ Lights Process Relays/ Timers Comm.

6.

You will need a standard USB or Ethernet cable for programming, depending on whether you use the USB or Ethernet programming port on the P3-550 CPU.

Select your PC-to-PAC programming cable.

Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

7.

Select tools, wire, and provide power.


Screwdriver DN-SS1 Wire Strippers DN-WS Hookup Wire

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-23

Programming Software
P3-PGMSW
for a limited time

($495 value)

FREE

Productivity Suite is user-friendly programming software designed to allow quick and easy programming of ladder logic programs for the Productivity3000 PAC.

Productivity Suite programming software works with Windows 2000 Service Pack 4, XP Home or Professional, or Vista (32 bit only). These are the minimum system requirements: Personal Computer with a 333 MHz or higher processor (CPU) clock speed recommended; Intel Pentium/Celeron family or AMD K6/Athlon/Duron family, or compatible processor recommended SVGA 800x600 pixels resolution. (1024x768 pixels resolution recommended) 150MB free hard-disk space 128MB free RAM (512MB recommended) CD-ROM or DVD drive for installing software from the CD USB or Ethernet port for project transfer to PAC

PC Requirements

The online help file provides information that will help you get acquainted with the software quickly.

Main window

The Main Window is displayed when the program opens. It is divided into Menus, Toolbars, and Windows that work together to make project development as simple as possible.

Programming Cable

You will need a standard USB or Ethernet cable for programming, depending on whether you use the USB or Ethernet programming port on the P3-550 CPU. We recommend using a USB programming cable; just plug it in and it works. We sell these A-to-B USB cables: USB-CBL-AB3 (3 ft.) USB-CBL-AB6 (6 ft.) USB-CBL-AB10 (10 ft.) USB-CBL-AB15 (15 ft.) Application
Tool Panel

Task Management Panel

Ladder Editor Window

Instruction Panel Window

Volume 13

e7-24

Programmable Controllers

1 - 80 0 - 633 - 0405

Bases
P3-03B P3-05B P3-08B P3-11B <---> <---> <---> <--->

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox

See Dimensions and Installation for base dimensions.

The P3-03B, P3-05B, P3-08B, and P3-11B are 3, 5, 8, and 11-slot, local, expansion, and remote I/O bases.
P3-05B 5-Slot Base

Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors

Input or Output Modules per Base Power Supply Slots CPU Slots Module Types Supported Module Placement Restrictions

3, 5, 8, or 11 1 (P3-01AC or P3-01DC) 1 (P3-550, P3-RS and P3-EX compatible) Discrete, analog and specialty None. Any I/O module may be installed in any I/O slot without power supply budget or module type restrictions. I/O Module Hot Swap Support Yes. (All discrete and analog modules can be software enabled for Hot Swap operation) Module Keying Electronic to slot Maximum Number of Local Bases 5

Base Specifications

Base Configuration

General Specifications
Operating Temperature Storage Temperature Humidity Shock Environmental Air Vibration Heat Dissipation

0 to 60C (32 to 140F)

-20 to 70C (-4 to 158F) IEC60068-2-6 (Test Fc) 2.5W

5 to 95% (non-condensing) IEC60068-2-27 (Test Ea)

AC Power Supply

No corrosive gases permitted

C P U
or

Discrete, Analog and Specialty I/O

Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers

or DC Power Supply

Agency Approvals

Weight

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. P3-03B: 1.365 lbs (21.8oz.), 619g P3-05B: 1.658 lbs (26.5oz.), 752g P3-08B: 2.158 lbs (34.5oz.), 978g P3-11B: 2.682 lbs (42.9oz.), 1216g

E x p a n s i o n

or

R e m o t e I/O

Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-25

Power Supplies
P3-01AC <---> P3-01AC Specifications
P3-01AC User Specifications
Input Voltage Range (Tolerance) Rated Operating Frequency Maximum Input Power Cold Start Inrush Current Maximum Inrush Current (Hot Start) Input Fuse Protection (Internal) Efficiency Output 100 to 240 VAC (-15% / +10%) 50 to 60 Hz with 5% tolerance 72W 12A 3mS 12A 3mS Micro fuse 250V, 2A, slow blow Non-replaceable 83% 24VDC @ 1.4A (10%) 5VDC @ 2.1A ( 5%) 3.3VDC @ 6.1A ( 5%)

The P3-01DC input power supply requires power from an external 24-48 VDC source.

The P3-01AC input power supply requires power from an external 100-240 VAC source.

There are two power supplies available; both provide isolated 24 VDC, 5 VDC, and 3.3 VDC to the Productivity3000 bases.

No power budgeting is required with either power supply. Any combination of I/O modules may be installed in any slots without power budget considerations.

No Power Budgeting

Maximum Output Power Heat Dissipation Isolated User 24VDC Output Output Protection for Over Current, Over Voltage, and Over Temperature Under Input Voltage Lock-out Over Input Voltage Lock-out Input Transient Protection Operating Design Life

57W Combined 17W None Self resetting for all three voltage outputs to base 55-65 VAC 265-280 VAC Varistor, plus input choke and filter 10 years at full load at 40C ambient and 5 years at 60C ambient

P3-01AC General Specifications


Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Enclosure Type Agency Approvals

Voltage Withstand (dielectric) Insulation Resistance Module Location EU Directive Weight

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.
P3-01AC

>10M @ 500VDC Power supply slot in any local, expansion, or remote base in a Productivity3000 System. See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 345g (12.1 oz)

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. 1900 VDC applied for 2 seconds

AC Input Power Supply

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Terminal Block Specifications


Number of Positions Pitch Wire Range Screw Driver Width Screw Size Screw Torque

IMPORTANT!
Note: This device cannot be Hot Swapped.
Volume 13

Hot-Swapping Information

4 Screw Terminals 0.3 inch (7.62 mm) 22-14AWG (0.324 to 2.08 sq. mm) Solid Conductor 22-14AWG (0.324 to 2.08 sq. mm) Stranded Conductor 3/64 inch (1.2mm) insulation maximum 1/4 inch (6.5mm) maximum M3 size 7- 9 inch-pounds (0.882 - 1.02 Nm)

e7-26

Programmable Controllers

1 - 80 0 - 633 - 0405

Power Supplies
P3-01DC <---> P3-01DC Specifications
P3-01DC User Specifications
Input Voltage Range (Tolerance) Maximum Input Ripple Maximum Input Power Cold Start Inrush Current Maximum Inrush Current (Hot Start) Input Fuse Protection (Internal) Input Reverse Polarity Protection Output 24 to 48 VDC (-10% / +20% at 60C) < 5% 67W 10.5A, 210S @ 24VDC 10.5A, 210S @ 24VDC Micro fuse 250V, 4A, Slow blow Non-replaceable Yes 24VDC @ 1.4A (10%) 5VDC @ 2.1A ( 5%) 3.3VDC @ 6.1A ( 5%) 57W Combined 14W None Self resetting for all three voltage outputs to base < 19.8 VDC None Varistor, plus input choke and filter 10 years at full load at 40C ambient and 5 years at 60C ambient 24 to 48 VDC (-15% / +20% at 55C)

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

The P3-01DC input power supply requires power from an external 24-48 VDC source.

The P3-01AC input power supply requires power from an external 100-240 VAC source.

There are two power supplies available; both provide isolated 24 VDC, 5 VDC, and 3.3 VDC to the Productivity3000 bases.

No power budgeting is required with either power supply. Any combination of I/O modules may be installed in any slots without power budget considerations.

No Power Budgeting

Maximum Output Power Heat Dissipation Isolated User 24VDC Output Output Protection for Over Current, Over Voltage, and Over Temperature Under Input Voltage Lock-out Over Input Voltage Lock-out Input Transient Protection Operating Design Life

P3-01DC General Specifications


Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Enclosure Type Agency Approvals

Voltage Withstand (dielectric) Insulation Resistance Module Location EU Directive Weight


P3-01DC

>10M @ 500VDC Power supply slot in any local, expansion, or remote base in a Productivity3000 System. See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 558g (19.7 oz)

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. 750 VDC applied for 2 seconds

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

DC Input Power Supply

impair suitability for Class I, Division 2.

WARNING: Explosion hazard Substitution of components may

Terminal Block Specifications


Number of Positions Pitch Wire Range Screw Driver Width Screw Size Screw Torque

IMPORTANT!
Note: This device cannot be Hot Swapped. Hot-Swapping Information

4 Screw Terminals 0.3 inch (7.62 mm) 22-14AWG (0.324 to 2.08 sq. mm) Solid Conductor 22-14AWG (0.324 to 2.08 sq. mm) Stranded Conductor 3/64 inch (1.2mm) insulation maximum 1/4 inch (6.5mm) maximum M3 size 7- 9 inch-pounds (0.882 - 1.02 Nm)

Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-27

Power Supplies
Power Supply Installation
Step One:

Power Connections
P3-01AC P3-01DC

Locate the left most socket in the base.

Insert the Power Supply at a 45 angle into the notch located at the top of the base and rotate down until seated in socket.

Step Two:

ACL ACN GND LOGIC GND

+V -V GND LOGIC GND

Step Three:

Snap the two retaining tabs into the locked position.

WARNING: Explosion hazard Do not connect or disconnect connectors


or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot swap.

A good common ground reference (earth ground) is essential for proper operation of the Productivity3000 system. One side of all control circuits, power circuits and the ground lead must be properly connected to earth ground by either installing a ground rod in close proximity to the enclosure or by connecting to the incoming power system ground. There must be a single-point ground (i.e. copper bus bar) for all devices in the enclosure that require an earth ground.

Grounding

Volume 13

e7-28

Programmable Controllers

1 - 80 0 - 633 - 0405

P3-550 CPU Module


The P3-550 is a full-featured, highperformance CPU. Features include a 4 line x 10 character LCD and seven communications ports which support USB, Ethernet and serial devices. Each Productivity3000 system requires one CPU module mounted in the controller slot in the first base of the local base group. The CPU stores and executes the users program.

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos

P3-550

<--->

P3-550

The system can be expanded with the P3-RS or P3-EX modules. The local, expansion, and remote I/O are assigned preconfigured or user-defined tagnames which can be easily referenced in the ladder logic program.
USB 2.0 (Type B) Port - Programming - Online monitoring 10/100 MB Ethernet Port - Programming - Online monitoring - Email (SMTP client) - Modbus TCP Client and Server Local Ethernet Network - GS Series drives - Remote IO USB 2.0 (Type A) Port - USB Flash Drive data logger - Project Transfer USB 2.0 (Type A) Port Local expansion bases (connect up to 4 expansion) bases per base group
UNLOCK

LCD - 4 x 10 character - 8 control buttons - User defined messages - User adjustable settings - PAC system errors / information CPU Status Indicators

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power

RS-232 Serial Port (RJ12) - Modbus/ASCII (master or slave) peripheral device RS-485 Serial Port (TB Style) - Modbus/ASCII (master peripheral device or multiple slave devices) using the same protocol

CPU Status Indicators


PWR RUN CPU

Green LED is illuminated when power is on Green LED is illuminated when CPU is in RUN mode Red LED is illuminated during power on reset, power down, or watch-dog time-out.

Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

CPU Run/Stop Switch


RUN position STOP position

Executes user program, run-time edits possible

Does not execute user program, normal program load position


Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-29

P3-550 CPU Module


The CPU incorporates a 4 line x 10 character LCD Display for system alarms and information or for displaying user-defined messages.

LCD Message Display

For user-defined messages, the display is configured using the Productivity Suite Programming Software. An LCD Page instruction allows the user to program text into user-defined tags and display the messages based on the ladder execution.

LCD control buttons located beneath the display allow the user to navigate through a menu, and arrow buttons allow for configuration of time and date settings.

Specifications
CPU Specifications
User Memory Memory Type Retentive Memory Scan Time Display Communications; 7 Integrated Ports 50MB (Includes program, data and documention) Flash and Battery Backed RAM 100K 600s (3K Boolean, 1K I/O) LCD, 4x10 characters, backlit, 8 control buttons; LCD characters are 5x7 with a dot pitch of 0.45mm; 2.25mm x 3.15mm USB IN: Programming, Monitoring, Debug, Firmware ETHERNET: (10/100Mbps Ethernet) Programming, Monitoring, Debug, Firmware, Email SMTP Client, Modbus TCP Master (64 Slaves) and Slave (8 Masters) REMOTE I/O: (10/100Mbps Ethernet) 32 P3-RS Remote Base Groups, and 64 GS-EDRV (GS Drives) USB OUT: (2.0) Data Logging or Project Transfer using SDCZ4-2048-A10 Pen Drive EXP I/O OUT: (2.0 Proprietary) 4 P3-EX Local Expansion Bases RS-232: (RJ12, 1200-115.2k Baud) ASCII, Modbus RS-485: Removable Terminal Included, (1200-115.2k Baud) ASCII, Modbus 33 Base Groups 1 Local (P3-550) + 32 Remote (P3-RS) 5 Bases per Base Group 1 P3-550 or P3-RS + 4 Expansion (P3-EX) 64 GS Series Drives as Remote I/O 165 Bases Total 1 P3-550, 32 P3-RS, & 132 P3-EX Instruction Types Application Functions Array Functions Counters/Timers Communications Data Handling Drum Sequencers Math Functions PID Program Control String Functions System Functions Contacts Coil

General Specifications
Storage Temperature Humidity Shock Environmental Air Vibration Heat Dissipation

Operating Temperature 0 to 60C (32 to 140F)

-20 to 70C (-4 to 158F) IEC60068-2-6 (Test Fc) 7W

5 to 95% (non-condensing) IEC60068-2-27 (Test Ea)

No corrosive gases permitted

Enclosure Type Agency Approvals

Module Location EU Directive

Hardware Limits of System

116,160 Hardware I/O Points (All 64-point I/O Modules)

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

Weight

260g (9 oz)

See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com

Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Controller slot in the local base in a Productivity3000 System

IMPORTANT!

Note: This device cannot be Hot Swapped.

Hot-Swapping Information

Volume 13

e7-30

Programmable Controllers

1 - 80 0 - 633 - 0405

P3-550 CPU Module


A battery is included with the P3-550 CPU, but is not installed. The battery can be installed to retain the Time and Date along with any Tagname values that are set up as retentive.

Company Information Systems Overview Programmable Controllers

Battery (Optional)

Step One:
Press spring lock and swing battery compartment away from CPU.

+
Step Tw Two:
Insert battery and ba close com compartment.

Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls

The battery is not needed for program backup.

Take care to insert battery behind metal tab.

Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers

Battery (Optional)

CPU Installation
Locate the two sockets next to the power supply; the CPU will be inserted into this location.

Coin type, 3.0V Lithium D2-BAT-1 battery, 560mA, battery number CR2354

Step One:

Insert the CPU at a 45 angle into the notch located at the top of the base and rotate down until seated.

Step Two:

Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

Step Three:

Snap retaining tab into the locked position.

Pneumatics Appendix Product Index Part # Index

WARNING: Explosion hazard Do not connect or disconnect connectors or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot swap.
Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-31

P3-550 CPU Module - Communications


Port Specifications
The P3-550 CPU has seven communications ports. The following pages list specifications and pin-out diagrams for these ports.

USB IN Port

Used exclusively for connecting to a PC running the Productivity Suite programming software.

USB Type B Slave Input Specifications


Port Name Description USB IN Standard USB 2.0 Slave input for programming and online monitoring, with built-in surge protection. Not compatible with older full speed USB devices.

Transfer Rate Port Status LED Cables

480 Mbps Green LED is illuminated when LINK is established to programming software. USB Type A to USB Type B: 3 ft. cable part # USB-CBL-AB3 6 ft. cable part # USB-CBL-AB6 10 ft. cable part # USB-CBL-AB10 15 ft. cable part # USB-CBL-AB15
4

1 2

Pin # 1 2 3 4

Signal +5 Data +Data GND

Mating face of USB type B female

Ethernet Port

RJ-45 style connector used for: Connection to a PC running the Productivity Suite programming software Modbus TCP Client connections (Modbus requests sent from the P3-550) Modbus TCP Server connections (Modbus requests received by the P3-550) Outgoing E-mail

RJ-45 style connector used for connecting to a Remote I/O network consisting of P3-RS Remote Slaves and/or GS-EDRV units with GS drives.

Remote I/O Port

Crossover Cable
TD+ 1 TD 2 RD+ 3 4 5 RD 6 7 8 RJ45 TD+ 1 TD 2 RD+ 3 4 5 RD 6 7 8 RJ45
OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN GRN/WHT GRN OR/WHT BLU BLU/WHT OR BRN/WHT BRN

10/BASE-T/100BASE-TX

Ethernet Specifications

1 2 3 4 5 6 7 8

TD+ TD RD+ RD

8 1

Patch (Straight-through) Cable


OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN

RJ45 1 2 3 4 5 6 7 8 TD+ TD RD+ RD

Port Name ETHERNET Description Standard transformer isolated Ethernet port with built-in surge protection for programming, online monitoring, Email (SMTP client) and Modbus/TCP client/server connections (fixed IP or DHCP).

REMOTE I/O Standard transformer isolated Ethernet port with built-in surge protection for connection to the P3-RS Remote I/O system. Supports 32 Remote I/O slaves and 64 GS Series drives.

Transfer 10/100 Mbps Rate Port Status Green LED illuminated when network LINK is established. Yellow LED LED is illuminated when port is active (ACT).
8-pin RJ45 Connector (8P8C)

12345678

Cables

Use a Patch (straight through) cable when a switch or hub is used. Use a Crossover cable (not offered by ADC) when a switch or hub is not used.

RJ45

Volume 13

e7-32

Programmable Controllers

1 - 80 0 - 633 - 0405

P3-550 CPU Module - Communications


Port Specifications
USB OUT Port
Used for data logging or project transfers to and from a SDCZ4-2048-A10 Pen Drive.
Port Name Description

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

EXP I/O OUT Port

USB port used only for Expansion I/O connections to local P3-EX modules in a Productivity3000 base with I/O.
EXP I/O OUT Proprietary USB 2.0 Master output for connection with up to four P3-EX local expansion bases, with built-in surge protection.

USB Type A Master Output Specifications


USB OUT Standard USB 2.0 Master output for connection to high-speed Flash drive (Sandisk SDCZ4-2048-A10) for data logging or program transfer with built-in surge protection. Not compatible with older full speed USB devices. A 0.5m male-to-female port extender cable is included to assist with Flash drive connection.

Transfer Rate 480 Mbps Port Status LED Cables

Green LED is illuminated when LINK is established to connected device None required

USB Type A to USB Type B:

6 ft. cable part # P3-EX-CBL6 (included with P3-EX module)


2 1

USB OUT

Pin # 1 2 3

Signal +5 Data + Data GND

RS-232 Port

Mating face of USB type A female

RJ-12 style connector used for: Modbus RTU Master connections Modbus RTU Slave connections ASCII Incoming and Outgoing communications Custom Protocol Incoming and Outgoing communications

EXP I/O OUT

Pin # 1 2 3 4

Signal Reset Data + Data GND

RS-232 Non-isolated RS-232 DTE port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable,1200, 2400, 9600, 19200, 33600, 38400, 57600, and 115200. +5V Cable Power 210mA maximum at 5V, +/- 5%. Reverse polarity and overSource load protected. TXD RTS RXD GND Maximum Output Load (TXD/RTS) Minimum Output Voltage Swing Output Short Circuit Protection Port Status LED Cable Options RS-232 Transmit output RS-232 Receive input Logic ground 3K , 1,000pf +/-5V Handshaking output for modem control.

Port Name Description

RS-232 Specifications

6 1
6-pin RJ12 Female Modular Connector

Pin # 1 2 3 4 5 6 GND +5V RXD TXD RTS GND

Signal Logic Ground 210 mA Maximum RS-232 Input RS-232 Output RS-232 Output Logic Ground

+/-15mA

Green LED is illuminated when active for TXD, RXD and RTS D2-DSCBL USB-RS232 with D2-DSCBL FA-CABKIT FA-ISOCON for converting RS-232 to isolated RS-485
Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-33

P3-550 CPU Module - Communications


Port Specifications
RS-485 Port
A 3-pin removable terminal block used for: Modbus RTU Master connections Modbus RTU Slave connections ASCII Incoming and Outgoing communications Custom Protocol Incoming and Outgoing communications

RS-485 Port Specifications


Port Name Description RS-485 Non-isolated RS-485 port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active.

Data Rates

TXD+/RXD+ TXD-/RXDGND Input Impedance

Selectable, 1200, 2400, 9600, 19200, 33600, 38400, 57600, and 115200. RS-485 transceiver high RS-485 transceiver low Logic ground 19K 50 transceivers, 19K

Removable connector included. Spare connectors available (part no. P3-RS485CON).

Maximum load Output Short Circuit Protection Electrostatic Discharge Protection Electrical Fast Transient Protection Minimum Differential Output Voltage Fail safe inputs Maximum Common Mode Voltage Port Status LED Cable Options

+/- 250mA, thermal shut-down protection +/-8KV per IEC1000-4-2 1.5V with 60 load +/-2KV per IEC1000-4-4.

each, 60

termination

Logic high input state if inputs are unconnected -7.5V to 12.5V. Green LED illuminated when active for TXD and RXD Recommend Belden #9841 or equivalent

Pin # G
Removable connector included. Spare connectors available (part no. P3-RS485CON).

Signal GND TXD-/RXDTXD+/RXD+

Volume 13

e7-34

Programmable Controllers

1 - 80 0 - 633 - 0405

P3-EX Expansion Module


The P3-EX high-performance expansion module provides local I/O expansion to a CPU or Remote I/O. Includes 6-foot USB expansion cable.

Company Information Systems Overview Programmable Controllers

P3-EX

<--->

P3-550 CPU

Field I/O Software

P3-EX
CPU
UNLOCK UNLOCK UNLOCK

P3-EX

Local Expansion Module

C-more & other HMI Drives Soft Starters

EX
UNLOCK UNLOCK UNLOCK

RUN ERR

P3-EX

Motors & Gearbox Steppers/ Servos

LNK

EXP I/O IN

P3-EX

Motor Controls Proximity Sensors Photo Sensors Limit Switches

LNK

EXP I/O OUT PWR

P3-EX

A 6-foot USB cable is included with the P3-EX module (Replacement cable: part number P3-EX-CBL6).

UNLOCK

ADC Stride Ethernet Switch

Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

The system can have up to 132 expansion bases by adding four expansion bases at the CPU base and four expansion bases per Remote I/O Slave (up to 32 slaves). Each expansion base uses the P3-EX expansion module for USB-based I/O bus connectivity.

Local Base Group

Remote Base Group

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-35

P3-EX Expansion Module


Module Specifications
Mounting Location Expansion Connectors Maximum Number of Expansion Modules per CPU or Remote Slave Maximum Distance Between Modules Status Indicators Controller slot of expansion base 1 USB 2.0 Type A, 1 USB 2.0 Type B 4 15 feet

I/O Capabilities Max. Number of I/O per CPU System Max. Number of Expansion I/O Bases

PWR - Green LED is illuminated when power is on. RUN - Green LED is illuminated when not in reset. Reset occurs during power-up, a watchdog timeout, or if an expansion cable is disconnected. ERR - Red LED is illuminated when a USB fault is detected. LINK - Green LED is illuminated when a USB link is established. 116,160 (CPU Base with 4 Expansion Bases plus 32 Remote Bases with 4 Expansion Bases per Remote, with 11 64-point I/O modules per base) 132 (4 per CPU, 4 per Remote Base) Automatic hardware verification Automatic via Tag Names 6 foot: P3-EX-CBL6 (USB Type A to USB Type B)

P3-EX
Local Expansion Module

CPU

Module Setup Expansion I/O Addressing USB Cables

EX

RUN

General Specifications
Operating Temperature Storage Temperature Humidity Shock Environmental Air Vibration Heat Dissipation

ERR

0 to 60C (32 to 140F)

LNK

-20 to 70C (-4 to 158F) IEC60068-2-6 (Test Fc) 1W

5 to 95% (non-condensing) IEC60068-2-27 (Test Ea)

No corrosive gases permitted

EXP I/O IN

USB 2.0 (Type B) Port - Input from P3-550, P3-RS or preceding expansion module

LNK

EXP I/O OUT PWR

Enclosure Type Agency Approvals

Module Location EU Directive Weight

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 194g (6.24 oz)

Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Controller slot in a local expansion base in a Productivity3000 System

USB 2.0 (Type A) Port - Output to subsequent expansion module

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

IMPORTANT!

Note: This device cannot be Hot Swapped.

Hot-Swapping Information

Expansion Module Status Indicators


PWR RUN ERR LNK

Green LED is illuminated when power is on. Green LED is illuminated when not in reset. Reset occurs during power-up, a watchdog timeout, or an expansion cable is disconnected. Red LED is illuminated when a USB fault is detected. Green LED is illuminated when a USB link is established.

Volume 13

e7-36

Programmable Controllers

1 - 80 0 - 633 - 0405

P3-EX Expansion Module


Port Specifications
Exp I/O Port Specifications
Port Name Description EXP I/O IN Proprietary USB 2.0 Slave input for connection with a CPU, Remote Slave, or preceding P3-EX expansion base. The P3-EX Expansion Module includes the 6 foot USB cable P3-EX-CBL6. Transfer Rate 480 Mbps Port Status LED Cables

Company Information Systems Overview Programmable Controllers Field I/O


4

EXP I/O IN
EXP I/O OUT Proprietary USB 2.0 Master output for connection with the next P3-EX expansion base. Includes built-in surge protection.
2 1

Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors

Mating face of USB type B female

Pin # 1 2 3 4

Signal Reset Data + Data GND

EXP I/O OUT


4 3 2 1

6 ft. cable part no. P3-EX-CBL6

Green LED is illuminated when LINK is established to connected device USB Type A to USB Type B:

Mating face of USB type A female

Installation Procedure
Step One:

Locate the two sockets next to the Power Supply.

Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

Step Two

Insert P3-EX at a 45 angle into the notch located at the top of the base and rotate down until seated.

Snap retaining tab into the locked position.

Step Three

or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot swap.

WARNING: Explosion hazard Do not connect or disconnect connectors

Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-37

P3-RS Remote Slave Module


The P3-RS is a full-featured, highperformance, Remote Slave module. Features include a 4 line x 10 charactor LCD display and five communications ports which support USB, Ethernet, and serial devices. Up to 32 P3-RS Remote Slaves can be connected to a single P3-550 CPU for a remote I/O network.

P3-RS

<--->

Rack with CPU Module

Racks with P3-RS Modules

Node 1 Node 1 P3-550

Node 1 Node 1

Stride Ethernet Switch

Node 2

P3-RS REMOTE SLAVE

SLAVE ADDRESS X1 X10

EXP I/O OUT

Add up to 32 Remote Base Groups using P3-RS Remote Slave modules and up to 64 GS Drives on the Remote I/O Ethernet Network.
Local Base Group Remote Base Group Remote Base Group

Add up to 4 bases to each group using P3-EX expansion modules with USB connections.

Volume 13

e7-38

Programmable Controllers

23

456

78

23

456

78

Configure each node with unique address.

REMOTE I/O

Up to Node 32

901 901

1 - 80 0 - 633 - 0405

P3-RS Remote Slave Module


Controller slot LCD, 4x10 characters, backlit, 8 control buttons; LCD characters are 5x7 with a dot pitch of 0.45mm; 2.25mm x 3.15mm Communications USB IN: (2.0, Type B) Programming, Monitoring, Debug 5 Integrated Ports REMOTE I/O: (10/100Mbps Ethernet) 1 P3-550 EXP I/O OUT: (2.0, Type A, Proprietary) 4 P3-EX Local Expansion Bases RS-232: (RJ12, 1200-115.2k Baud) ASCII, Modbus RS-485: (Removable Terminal Included, 1200-115.2k Baud) ASCII, Modbus Max. Number of Ethernet 32 Remote I/O Bases Max. Number of 132 (4 per CPU, 4 per Remote Base) Expansion I/O Bases Max. Number of I/O per 116,160 (CPU Base with 4 Expansion Bases plus 32 CPU System Remote Bases with 4 Expansion Bases per Remote, with 11 64-point I/O modules per base) Mounting Location Display

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Remote Slave Specifications

General Specifications
Operating Temperature Storage Temperature Humidity Shock Environmental Air Vibration Heat Dissipation

0 to 60C (32 to 140F)

-20 to 70C (-4 to 158F) IEC60068-2-6 (Test Fc) 4W

5 to 95% (non-condensing) IEC60068-2-27 (Test Ea)

No corrosive gases permitted

Enclosure Type Agency Approvals

Module Location EU Directive Weight

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Controller slot in a remote base in a Productivity3000 System See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 260g (9 oz)

IMPORTANT!

Note: This device cannot be Hot Swapped.


impair suitability for Class I, Division 2.

Hot-Swapping Information

WARNING: Explosion hazard Substitution of components may

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-39

P3-RS Remote Slave Module


Front Panel Status Indicators
RS Status Indicators
PWR RUN CPU Green LED is backlit when power is on

P3-RS REMOTE SLAVE

USB 2.0 (Type B) Port - Programming - Online monitoring

LCD - Backlit screen - 4 x 10 character - User defined alarms/ messages - PLC system alarms / information

Green LED is backlit when CPU is in RUN mode Red LED is backlit during power on reset, power down, or watch-dog time-out.

Status Indicators 10/100 MB Ethernet connection to the Remote I/O port on the P3-550 CPU.
REMOTE I/O

SLAVE ADDRESS X1 X10

EXP I/O OUT

The P3-RS incorporates a 4 line x 10 character LCD for system errors and information or for displaying userdefined messages.

LCD

USB 2.0 (Type A) Port Local expansion bases (connect up to 4 expansion bases per base group)

LCD characters are 5x7 with a dot pitch of 0.45mm; 2.25mm x 3.15mm.

For user-defined messages, the display is configured using the Productivity Suite Programming Software. An LCD Page instruction allows the user to program text into user-defined tags and display the messages based on the ladder execution. See the Productivity Suite Programming Software Help Files for complete details.
Volume 13

e7-40

Programmable Controllers

23

Address Rotary Switch Set the Remote I/O Slave Address (1-99) using the rotary switches.

456

78

23

456

78

RS-232 Serial Port (RJ12) - Modbus/ASCII (master or slave) peripheral device

901 901

RS-485 Serial Port (TB Style) - Modbus/ASCII (master peripheral device or multiple slave devices using the same protocol)

P3-RS

1 - 80 0 - 633 - 0405

P3-RS Remote Slave Module


Each Remote Slave must have a unique address between 1 and 99. The address is set using the two rotary switches located on the face of the module, X10 for setting the tens units and X1 for setting the ones unit.

Company Information Systems Overview Programmable Controllers Field I/O


P3-RS REMOTE SLAVE

Setting the Remote Slave Address

Software C-more & other HMI Drives

SLAVE ADDRESS SLAVE ADDRESS ADDRESS X1 X10

SLAVE ADDRESS X1 X10

X1 X1

456

For example, if connected online to a P3000 system with slaves installed, go to Hardware Configuration and select the Read Configuration (1) button. The CPU will automatically read the addresses of the remote slaves and add them to the configuration.

It is also necessary to configure the remote addresses using the Productivity Suite Programming Software.

1 2 3

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

23

IMPORTANT NOTES: The factory setting of 00 is not a valid address. Address selection must be set prior to power-up. Slave addresses are only read on power-up. If there are duplicate P3-RS slave addresses on the same network, a critical error will be displayed on the CPU.

EXP I/O OUT

Programmable Controllers

23

78

456

78

23

23

23

For example, to set a remote slave address to 21, turn the X10 arrow until it points at number 2 and the X1 arrow until it points at number 1.

456

78

REMOTE I/O

456

X10 X10

456

23

456

78

901 901
78
78

Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

901

901 901

901

Volume 13

e7-41

P3-RS Remote Slave Module


The P3-RS has five communications ports. The following pages have specifications and pin-out diagrams for these ports.

Port Specifications

Standard USB 2.0 (Type B) Slave input for remote CPU programming and online monitoring, with built-in surge protection.

USB IN Port

USB IN Specifications
Description Transfer Rate Port Status LED Cables

480 Mbps Green LED is illuminated when LINK is established to programming software. USB Type A to USB Type B: 10 ft. cable part # USB-CBL-AB10 6 ft. cable part # USB-CBL-AB6 3 ft. cable part # USB-CBL-AB3

Standard USB 2.0 (Type B) Slave input for remote CPU programming and online monitoring, with built-in surge protection. Not compatible with older full speed USB devices.

2 1

Pin # 1 2 3 4

Signal +5 Data +Data GND

Mating face of USB type B female

15 ft. cable part # USB-CBL-AB15

Isolated Ethernet Port with built-in surge protection for connection to P3-550 CPU Remote I/O Master port.
Crossover Cable
TD+ 1 TD 2 RD+ 3 4 5 RD 6 7 8 RJ45 TD+ 1 TD 2 RD+ 3 4 5 RD 6 7 8 RJ45
OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN GRN/WHT GRN OR/WHT BLU BLU/WHT OR BRN/WHT BRN

Remote I/O Port

Description Port Status LEDs Cables

Transfer Rate

Green LED is illuminated when network LINK is established. Yellow LED backlit when port is active (ACT).

Proprietary transformer isolated Ethernet Port with built-in surge protection for connection to CPU Remote I/O Master port. 10/100 Mbps

1 2 3 4 5 6 7 8

TD+ TD RD+ RD

8 1

Use a Patch (straight-through) cable when a switch or hub is used. Use a Crossover cable when a switch or hub is not used.

Patch (Straight-through) Cable


OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN OR/WHT OR GRN/WHT BLU BLU/WHT GRN BRN/WHT BRN

RJ45 1 2 3 4 5 6 7 8 TD+ TD RD+ RD

RJ45

8-pin RJ45 Connector (8P8C)

12345678

Volume 13

e7-42

Programmable Controllers

1 - 80 0 - 633 - 0405

REMOTE I/O

Remote I/O Port Specifications

P3-RS Remote Slave Module


Port Specifications
EXP I/O OUT Port
USB 2.0 (Type A) Master output for connection to up to four P3-EX local expansion bases, with built-in surge protection.
4 3 2 1

Company Information Systems Overview Programmable Controllers

Pin # 1 2 3 4

Signal Reset Data + Data GND

Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches

Mating face of USB type A female

EXP I/O OUT Specifications


Description Port Status LED Cables Transfer Rate 480 Mbps

Proprietary USB 2.0 (Type A) Master output for connection with up to four P3-EX local expansion bases, with built-in surge protection.

Green LED is illuminated when LINK is established to connected device USB Type A to USB Type B. The P3-EX Expansion Module includes a 6 foot USB cable, part number P3-EX-CBL6.

RS-232 Serial Port

Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Non-isolated RS-232 DTE port connects the P3-RS as a Modbus or ASCII master or slave to a peripheral device.

6 1
6-pin RJ12 Female Modular Connector

Pin # 1 2 3 4 5 6 GND +5V RXD TXD RTS GND

Signal Logic Ground 210 mA Maximum RS-232 Input RS-232 Output RS-232 Output Logic Ground

Non-isolated RS-232 DTE port connects the P3-RS as a Modbus or ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable,1200, 2400, 9600, 19200, 33600, 38400, 57600, and 115200. +5V Cable Power 210mA maximum at 5V, +/- 5%. Limited by resettable fuse. Source Reverse polarity protected. TXD RTS RXD GND Maximum Output Load (TXD/RTS) Minimum Output Voltage Swing Output Short Circuit Protection Port Status LED Cable Options RS-232 Transmit output RS-232 Receive input Logic ground 3K , 1,000pf +/-5V Handshaking output for modem control.

Description

RS-232 Specifications

+/-15mA

Green LED is illuminated when active for TXD, RXD and RTS D2-DSCBL USB-RS232 with D2-DSCBL FA-CABKIT FA-ISOCON for converting RS-232 to isolated RS-485

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-43

P3-RS Remote Slave Module


Port Specifications
Non-isolated RS-485 port connects the P3-RS as a Modbus or ASCII master or slave to a peripheral device.

RS-485 Serial Port

Pin # G
Removable connector included. Spare connectors available (part no. P3-RS485CON).

Signal GND TXD-/RXDTXD+/RXD+

Removable connector included. Spare connectors available (part no. P3-RS485CON).

RS-485 Specifications
Description Data Rates

TXD+/RXD+ TXD-/RXDGND Input Impedance

Selectable, 1200, 2400, 9600, 19200, 33600, 38400, 57600, and 115200. RS-485 transceiver high RS-485 transceiver low Logic ground 19K 50 transceivers, 19K

Non-isolated RS-485 port connects the P3-RS as a Modbus or ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active.

Maximum load Output Short Circuit Protection Electrostatic Discharge Protection Electrical Fast Transient Protection Minimum Differential Output Voltage Fail safe inputs Maximum Common Mode Voltage Port Status LED Cable Options

+/- 250mA, thermal shut-down protection +/-8KV per IEC1000-4-2 1.5V with 60 load +/-2KV per IEC1000-4-4.

each, 60

termination

Installation Procedure
Locate the two sockets next to the power supply; the P3-RS will be inserted into this location.

Logic high input state if inputs are unconnected -7.5V to 12.5V. Green LED is illuminated when active for TXD and RXD Recommend Beldon #9841 or equivalent

Step One:

Insert P3-RS at a 45 angle into the notch located at the top of the base and rotate down until seated.

Step Two:

Step Three:

Snap retaining tab into the locked position.

WARNING: Explosion hazard Do not connect


or disconnect connectors or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot swap.

Volume 13

e7-44

Programmable Controllers

1 - 80 0 - 633 - 0405

Dimensions and Installation


It is important to review and understand the installation requirements for your Productivity3000 system. Your knowledge of these requirements will help ensure that your system operates within its environmental and electrical limits. This catalog should never be used as a replacement for the product inserts and user manual. Each base, CPU, power supply, I/O module, remote slave, and expansion module comes with a product insert. You can purchase, download for free, or view online the Productivity3000 user manual (P3-USER-M). These documents, along with the software help files, contain important safety information that must be followed.
2 50mm min 2 50mm min 3 76mm min 7 2 7.2 183mm min

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm.

Plan for Safety

3 76mm min

Enclosures

The system installation should comply with all appropriate electrical codes and standards.
2 50mm min

Your selection of a proper enclosure is important to ensure safe and proper operation of your Productivity3000 system. Applications for the Productivity3000 system vary and may require additional hardware considerations. The minimum considerations for enclosures include: Conformance to electrical standards Protection from the elements in an industrial environment Common ground reference Maintenance of specified ambient temperature Access to the equipment Security or restricted access Sufficient space for proper installation and maintenance of the equipment

OK

AIRFLOW

Mount the bases horizontally, as shown in the illustration, to provide proper ventilation. Do not mount the bases vertically, upside down, or on a flat horizontal surface.

Mounting Position

3 [76mm]
NOTE: Add 3 inches (76 mm) to mounting depth when using ZIPLink cable ZL-CBL40.

Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-45

Dimensions and Installation


Provide a minimum clearance of 2 inches (50mm) between the bases and all sides of the enclosure. Allow extra door clearance for operator panels and other door mounted items. There should be a minimum of 3 inches (76mm) clearance between the base and any wire duct, and a minimum of 7.2 inches (183mm) from base to base in a multiple base installation. A good common ground reference (earth ground) is essential for proper operation of the Productivity3000 system. One side of all control circuits, power circuits and the ground lead must be properly connected to earth ground by either installing a ground rod in close proximity to the enclosure or by connecting to the incoming power system ground. There must be a single-point ground (i.e. copper bus bar) for all devices in the enclosure that require an earth ground.

Mounting Clearances

Base Dimensions
8.50 [215.9] 4.75 [120.7]

6.00 [152.4]

P3-03B P3-03B

5.63 [143.0]

Grounding

7.56 [192.0] 11.25 [285.6]

6.00 [152.4]

P3-05B P3-05B

5.63 [143.0]

inches [mm]

10.31 [261.9] 15.44 [392.2]

6.00 [152.4]

P3-08B P3-08B

5.63 [143.0]

The Productivity3000 system should be installed within the operating temperature specifications as listed in this document. If the temperature deviates above or below the specification, measures such as cooling or heating the enclosure should be taken to maintain the specification.

Temperature Considerations

14.50 [368.3] 19.56 [496.8]

6.00 [152.4]

P3-11B P3-11B

5.63 [143.0]

9.88 [251.0]

8.75 [222.3]

Power Considerations

The Productivity3000 system is designed to be powered by 110/220 VAC or 24/48 VDC via one of the P3000 power supplies. The Productivity3000 has achieved CE certification without requiring EMF/RFI line noise filters on the AC power supply. Please review the "EU Directives" document, located in the User Manual or at www.productivitypac.com, for applications which require CE Compliance.

Volume 13

e7-46

Programmable Controllers

1 - 80 0 - 633 - 0405

Base Installation
The Productivity3000 bases can be secured to the cabinet using mounting rails. You should use rails that conform to DIN EN standard 50 022. We offer a complete line of DIN rail, DINnectors and DIN rail mounted apparatus. These rails are approximately 35mm high, with a depth of 7.5mm. If you mount the base on a rail, you should also consider using end brackets on each side of the base. The end brackets help keep the base from sliding horizontally along the rail. This helps minimize the possibility of accidentally pulling the wiring loose.

Company Information Systems Overview Programmable Controllers

Using Mounting Rails

End Bracket (Part No. DN-EB35)

DIN Rail Dimensions


7.5 mm

Field I/O Software C-more & other HMI Drives

35 mm

DIN Rail (Part No. DN-R35S1)

Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors

If you examine the bottom of the base, you'll notice retaining clips. To secure the base to a DIN rail, place the base onto the rail and gently push up on the retaining clips. The clips lock the base onto the rail. To remove the base, pull down on the retaining clips, slightly lift up the base, and pull it away from the rail.

Hook base onto DIN rail at top of mounting slot.

Photo Sensors Limit Switches Encoders

2
Rotate base into position.

Gently push up retaining clips.

Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring

Retaining Clips

Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-47

Wiring I/O Modules


There are two available methods for wiring most I/O modules: The ZIPLink wiring system or hand wiring to the optional removable I/O module terminal blocks.

Note: The high-density 32-point and 64point I/O module design requires the use of the ZIPLink wiring system. Thermocouple and RTD modules are not compatible with the ZIPLink system and are shipped with the optional terminal blocks included. For wiring I/O modules, we strongly recommend using pre-wired ZIPLinks wiring systems, which eliminate the need for hand wiring modules to terminal blocks.

ZIPLinks Wiring Systems

See the selection matrix on the following page.

ZIPLink Module

ZIPLink Pre-Wired Terminal Block Cable

ZIPLink Pigtail Cable

Removable Terminal Blocks

Terminal Block Removal


2. Loosen selfjacking screws to disengage terminal block.

For most I/O modules you can also purchase a removable terminal block (part no. P3-RTB).

3. Grip opened door along edge to avoid flexing door and pull terminal block from module.

Note: P3-RTB supplied with thermocouple and RTD modules. P3-RTB not compatible with 32-point and 64-point I/O modules.

1. Pull hinged door open here.

NOTE: Do not grip door in middle.

Removable Terminal Block P3-RTB

Volume 13

e7-48

Programmable Controllers

1 - 80 0 - 633 - 0405

Specify your ZIPLink system


Use the Compatibility Matrix table below. Step 1 Step 2 Step 3
1

Wiring System for Productivity3000

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives

Locate the I/O module part number. Locate Connector Module Type. (Feedthrough Module, Fuse Module, etc...) Select the cable length by replacing the # symbol with: Blank = 0.5m, -1 = 1.0m, -2 = 2.0m1

Note: Cable part number denotes compatibility between Connector Module and I/O Modules.

ZipLink Wiring System Compatibility Matrix for Productivity3000


Step 2: Connector Module Feedthrough Modules Type ZL-RTB40 Step 1: I/O Number of ZL-RTB20 Module Terminals Step 3: Cables P3-08NAS P3-08ND3S P3-16NA P3-16ND3 P3-32ND3 P3-64ND3* P3-08TAS P3-08TD1S P3-08TD2S P3-08TRS P3-16TA P3-16TD1 P3-16TD2 P3-16TR P3-08TRS-1*** P3-32TD1 P3-32TD2 P3-64TD1* P3-64TD2* P3-04ADS P3-08AD P3-16AD-1 P3-16AD-2 P3-08RTD** P3-08THM** P3-04DA P3-08DA-1 P3-08DA-2 P3-06DAS-1 P3-06DAS-2 P3-16DA-1 P3-16DA-2 P3-8AD4DA-1 P3-8AD4DA-2
20 20 20 20 40 40 20 20 20 20 20 20 20 20 20 40 40 40 40 20 20 20 20 Matched Only T/C Wire Only ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20# ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-CBL40# ZL-CBL40# ZL-CBL40# ZL-CBL40# ZL-P3-CBL20-#L ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-CBL40# ZL-CBL40# ZL-CBL40# ZL-CBL40# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20# ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-CBL40# ZL-CBL40# ZL-P3-CBL20-#L ZL-CBL40# ZL-CBL40#

Fuse Modules
ZL-RFU20 ZL-RFU40

Relay Modules
ZL-RRL16-24

Sensor Input Modules


ZL-LTB16-24 ZL-LTB32-24

Pigtail Cable

Soft Starters Motors & Gearbox

Inputs
ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P

Steppers/ Servos Motor Controls Proximity Sensors

Outputs
ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P

Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process

I/O Module

Analog In
ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P

Relays/ Timers Comm. Terminal Blocks & Wiring Power

Analog Out
20 20 20 20 20 20 20 20 20 ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P ZL-P3-CBL20-#P

Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Analog Combo
ZL-P3-CBL20-#L ZL-P3-CBL20-#L ZL-P3-CBL20-#P ZL-P3-CBL20-#P

*The P3-64ND3, P3-64TD1, and P3-64TD2 modules have two 32-point connectors and require 2 ZIPLink cables and 2 ZIPLink connector modules. **These modules are not supported by the ZIPLink wiring system. Removable terminal block P3-RTB included. ***The P3-08TRS-1 output module is derated, not to exceed 2A per point maximum when used with the ZIPLink wiring system.
Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-49

I/O Modules
A variety of discrete and analog I/O modules are available for use in local, expansion, and remote I/O bases. Specifications for each module are on the following pages. A filler module is available for unused I/O module slots (part number P3-FILL).

Discrete Output Modules


Productivity3000 Discrete Output Modules
Part Number Number of Outputs 8 P3-08TD1S 8 P3-08TD2S 16 P3-16TD1 16 P3-16TD2 32 P3-32TD1* 32 P3-32TD2* 64 P3-64TD1* 64 P3-64TD2* 8 P3-08TAS 16 P3-16TA 8 P3-08TRS 16 P3-16TR 8 P3-08TRS-1
*ZIPLink required.

Description
Isolated Sinking Output Isolated Sourcing Output Sinking Output Sourcing Output Sinking Output Sourcing Output Sinking Output Sourcing Output Isolated AC Output AC Output Isolated Relay Output Relay Output Isolated Relay Output

Price
<---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <---> <--->

Discrete Input Modules


Productivity3000 Discrete Input Modules
Part Number Number of Inputs 16 P3-16SIM 8 P3-08ND3S 16 P3-16ND3 32 P3-32ND3* 64 P3-64ND3* 8 P3-08NAS 16 P3-16NA
*ZIPLink required.

Description
Input Simulator Module Isolated Sinking/Sourcing DC Input Sinking/Sourcing DC Input Sinking/Sourcing DC Input Sinking/Sourcing DC Input Isolated AC Input AC Input

Price
<---> <---> <---> <---> <---> <---> <--->

Analog I/O Modules


Productivity3000 Analog Input Modules
Description
Isolated Analog Input Analog Input Analog Input (Current) Analog Input (Voltage) Analog RTD Input Analog Thermocouple Input

Module Installation Procedure


Align here

WARNING: Do not apply field power until the

Part Number Number of Channels 4 P3-04ADS 8 P3-08AD 16 P3-16AD-1 16 P3-16AD-2 8 P3-08RTD 8 P3-08THM

Price
<---> <---> <---> <---> <---> <--->
Align here

following steps are completed. See hot-swapping procedure for exceptions.

Step One: Align circuit card with slot


and press firmly to seat module into connector.

Step Two: Pull top and

bottom locking tabs toward module face. Click indicates lock is engaged.

Productivity3000 Analog Output Modules


Part Number Number of Channels 4 P3-04DA 8 P3-08DA-1 8 P3-08DA-2 6 P3-06DAS-1 6 P3-06DAS-2 16 P3-16DA-1 16 P3-16DA-2 Description
Analog Output Analog Output (Current) Analog Output (Voltage) Isolated Analog Output (Current) Isolated Analog Output (Voltage) Analog Output (Current) Analog Output (Voltage)

Price
<---> <---> <---> <---> <---> <---> <--->

wiring using optional terminal block or ZIPLink wiring system and install cover.

Step Three: Attach field

To install or remove terminal block cover, press middle to flex cover.

Productivity3000 Analog Input/Output Modules


Part Number P3-8AD4DA-1 P3-8AD4DA-2 Number of Channels
8/4 8/4

Description
Analog Input/Output (Current) Analog Input/Output (Voltage)

Price
<---> <--->

WARNING: Explosion hazard Do not connect or disconnect connectors


or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot-swap modules unless the area is known to be non-hazardous.

Volume 13

e7-50

Programmable Controllers

1 - 80 0 - 633 - 0405

Input Simulator / Filler Module


P3-16SIM <--->
The P3-16SIM Input Simulator module provides 16 toggle switches to simulate input devices.
C

Company Information Systems Overview Programmable Controllers

Input Simulator Module

Input Specifications
Inputs per Module OFF to ON Response ON to OFF Response Status Indicators

16 Internal switches Max. 20 ms Max. 20 ms Logic Side (16 points)

Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Heat Dissipation Enclosure Type Agency Approvals

UL
R

US

2 3 4 5

6 7 8 16

9 10 11

12 13 14 15

Input Simulator

P3-16SIM

OFF ON 1 2 3 4 5 6 7 8

OFF ON 9 10 11 12 13 14 15 16

Module Location EU Directive Weight

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 0.25W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 120g (4.23 oz)

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

P3-16SIM

P3-FILL

Filler Module

<--->

The P3-FILL filler module protects unused I/O module slots in the base.

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-51

DC Input Modules
P3-08ND3S
Isolated Sinking/Sourcing Input

<--->

Input Specifications
Inputs per Module Operating Voltage Range (Tolerance) Peak Voltage Input Current (Typical) CE UL

The P3-08ND3S DC Input Module provides eight 12-24 VDC sinking or sourcing isolated inputs.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Terminal Type (not included) Commons

8 (sinking / sourcing) 12-24 VDC ( 10%) 12-24 VDC ( 10%) 26.4 VDC 5 mA @ 12 VDC 11 mA @ 24 VDC 12.5 mA @ 60 C (26.4 VDC) 2.2k @ 12-24 VDC > 10 VDC < 3 VDC 4 mA 2 mA Max. 2 ms Typical 1ms Max. 2 ms Typical 1ms Logic Side (8 points) 20-position removable terminal block 8 Isolated (1 point / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500 VAC applied for 1 minute >10M @ 500 VDC 2.81W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 80g (2.82 oz) Weight

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Volume 13

e7-52

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Input Modules
P3-08ND3S (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI

Sinking Field Device

Sourcing Field Device

Drives Soft Starters Motors & Gearbox


Sinking Field Device Sourcing Field Device

Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-53

DC Input Modules
P3-16ND3
Sinking/Sourcing Input

<--->

The P3-16ND3 DC Input Module provides sixteen 12-24 VDC sinking or sourcing inputs with four isolated commons.
C

Inputs per Module Operating Voltage Range (Tolerance) Peak Voltage Input Current (Typical)

Input Specifications
CE UL

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Terminal Type (not included) Commons

16 (sinking / sourcing) 12-24 VDC ( 10%) 12-24 VDC ( 10%) 26.4 VDC 5 mA @ 12 VDC 11 mA @ 24 VDC 12.5 mA @ 60 C (26.4 VDC) 2.2k @ 12-24 VDC > 10 VDC < 3 VDC 4 mA 2 mA Max. 2 ms Typical 1ms Max. 2 ms Typical 1ms Logic Side (16 points) 20-position removable terminal block 4 Isolated (4 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 5.61W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 80g (2.82 oz)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Volume 13

e7-54

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Input Modules
P3-16ND3 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI

Sinking Field Device

Sourcing Field Device

C1 1 2 3 4 C2 5 6 7 8 C3 9 10 11 12 C4 13 14 15 16
Sinking Field Device Sourcing Field Device

Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-55

DC Input Modules
P3-32ND3
Sinking/Sourcing Input

<--->

The P3-32ND3 DC Input Module provides thirty-two 24 VDC sinking or sourcing inputs with four isolated commons.
C

UL
R

US

No terminal block sold for this module; ZIPLink required.

Inputs per Module Operating Voltage Range (Tolerance) Peak Voltage Input Current (Typical) Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Connector Type Commons

Input Specifications
CE UL

32 (sinking / sourcing) 24 VDC ( 10%) 24 VDC ( 10%) 26.4 VDC 5 mA @ 24 VDC 6 mA @ 60 C (26.4 VDC) 4.7k @ 24 VDC > 18 VDC < 8 VDC 3.5 mA 2 mA Max. 2 ms Typical 1ms Max. 2 ms Typical 1ms Logic Side (32 points) 40-pin IDC 4 Isolated (8 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 5.96W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 120g (4.23 oz)

Connector Specifications
See Wiring Systems for part numbers of ZIPLink cables and connection modules required with this I/O module.
Connector Type Number of Pins Pitch

IDC style header with latch, Omron XG4A-4034 40 point 0.1 in. (2.54 mm)

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-56

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Input Modules
P3-32ND3 (contd)
Wiring Diagrams
Sinking Field Device Sourcing Field Device

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos
Sinking Field Device Sourcing Field Device

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-57

DC Input Modules
P3-64ND3
The P3-64ND3 DC Input Module provides sixty-four 24 VDC sinking or sourcing inputs with eight isolated commons.
UL
R

Sinking/Sourcing Input

<--->

US

Inputs per Module Operating Voltage Range (Tolerance) Peak Voltage Input Current (Typical) Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Connector Type Commons

Input Specifications
CE UL

64 (sinking / sourcing) 24 VDC ( 10%) 24 VDC ( 10%) 26.4 VDC 2.7 mA @ 24 VDC 3.5 mA @ 60 C (26.4 VDC) 8.2k @ 24 VDC > 18 VDC < 8 VDC 2 mA 1.1 mA Max. 2 ms Typical 1ms Max. 2 ms Typical 1ms Logic Side (32 points x 2) Two 40-pin IDC 8 Isolated (8 points / common)

2.7mA

General Specifications
No terminal block sold for this module; ZIPLink required.
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 6.91W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com 170g (6.00 oz) Weight

Connector Specifications
See Wiring Systems for part numbers of ZIPLink cables and connection modules required with this I/O module.
Connector Type Number of Pins Pitch

IDC style header with latch, Omron XG4A-4034 40 point x 2 0.1 in. (2.54 mm)

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-58

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Input Modules
P3-64ND3 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI

24VDC Sourcing Sinking Field Device Field Device

24VDC Sourcing Sinking Field Device Field Device

Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors
C2 C2

C1

C1

Photo Sensors Limit Switches Encoders

C3

C3

Current Sensors Pressure Sensors Temperature Sensors

C4

C4

Pushbuttons/ Lights Process Relays/ Timers Comm.

24VDC
Sinking Field Device Sourcing Field Device

Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-59

AC Input Modules
P3-08NAS
AC Isolated Input

<--->

Input Specifications
Inputs per Module Operating Voltage Range (Tolerance) AC Frequency Input Current (Typical) CE UL

The P3-08NAS AC Isolated Input Module provides eight 100-240 VAC isolated inputs.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Terminal Type (not included) Commons

8 100-240 VAC ( 20%) 100-240 VAC ( 20%) 47 - 63 Hz 8.5 mA @ 100 VAC (50 Hz) 10 mA @ 100 VAC (60 Hz) 17 mA @ 240 VAC (50 Hz) 20 mA @ 240 VAC (60 Hz) 26 mA @ 60 C (288 VAC) 15k (50 Hz), 12k (60 Hz) > 70 VAC < 20 VAC 5 mA 2 mA < 10 ms < 25 ms Logic side (8 points) 20-position removable terminal block 8 Isolated (1 point / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 4.38W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 95g (3.35 oz)

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Volume 13

e7-60

Programmable Controllers

1 - 80 0 - 633 - 0405

AC Input Modules
P3-08NAS (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

50 - 60 Hz

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-61

AC Input Modules
P3-16NA
AC Input

<--->

Input Specifications
Inputs per Module Operating Voltage Range (Tolerance) AC Frequency Input Current (Typical) CE UL

The P3-16NA AC Input Module provides sixteen 100-240 VAC isolated inputs with four isolated commons.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Maximum Input Current @ Temp Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Terminal Type (not included) Commons

16 100-240 VAC ( 20%) 100-240 VAC ( 20%) 47 - 63 Hz 8.5 mA @ 100 VAC (50 Hz) 10 mA @ 100 VAC (60 Hz) 17 mA @ 240 VAC (50 Hz) 20 mA @ 240 VAC (60 Hz) 26 mA @ 60 C (288 VAC) 15k (50 Hz), 12k (60 Hz) > 70 VAC < 20 VAC 5 mA 2 mA < 10 ms < 25 ms Logic side (16 points) 20-position removable terminal block 4 Isolated (4 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 8.76W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 95g (3.35 oz)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.
Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Removable Terminal Block Specifications

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Volume 13

e7-62

Programmable Controllers

1 - 80 0 - 633 - 0405

AC Input Modules
P3-16NA (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-63

DC Output Modules
P3-08TD1S <--->
Sinking Output
The P3-08TD1S DC Output Module provides eight 6-27 VDC sinking outputs with four isolated commons.
C

Output Specifications

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Terminal Type (not included) Status Indicators External 24 V Error Indicator Commons External DC Power required

Note:

8 (sinking) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / + 10%) 2A / point, 4A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.4 VDC @ 2A 4A for 10 ms, per point 1 ms 1 ms 20-position removable terminal block Logic Side (8 points) Logic Side (4 points) 4 Isolated (2 points / common) 24 VDC 10%, 30 mA

FLT (fault) indicates the absence of 24 VDC at a V1, V2, V3, or V4 terminal.

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 7.69W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 110g (3.88 oz)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-64

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-08TD1S (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI

C1 +V1 2 Shown rating in figure is an operating voltage C2 3 C3 +V3 6 C4 7

C1 +V1 2 C2 3 C3 +V3 6 C4 7

Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Each C4 terminal is connected inside the module.

Each C3 terminal is connected inside the module.

Each C2 terminal is connected inside the module.

Each C1 terminal is connected inside the module.

24VDC

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-65

DC Output Modules
P3-08TD2S
Sourcing Output

<--->

Output Specifications

The P3-08TD2S DC Output Module provides eight 6-27 VDC sourcing outputs with four isolated commons.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Terminal Type (not included) Status Indicators Commons

8 ( sourcing) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / + 10%) 2A / point, 4A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.4 VDC @ 2A 4A for 10 ms 1 ms 1.5 ms 20-position removable terminal block Logic Side (8 points) 4 Isolated (2 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 8.46W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 110g (3.88 oz)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-66

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-08TD2S (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-67

DC Output Modules
P3-16TD1
Sinking Output

<--->

Output Specifications

The P3-16TD1 DC Output Module provides sixteen 6-27 VDC sinking outputs with two isolated commons.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Terminal Type (not included) Status Indicators External 24 V Error Indicator Commons External DC Power required

16 (sinking) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / + 10%) 0.5A / point, 4A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.12 VDC @ 0.5A 2A for 10 ms 1 ms 1 ms 20-position removable terminal block Logic Side (16 points) Logic Side (2 points) 2 Isolated (8 points / common) 24 VDC 10%, 30 mA

Note: FLT (fault) indicates the absence of 24 VDC at V1 or V2 terminal.

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 2.41W Open Equipment UL508 and UL 1604 (Certified for Canada and USA) CE (EN61131-2*) This equipment is suitable for use in Class I, Division 2/Zone 2, Groups A, B, C, and D or nonhazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 125g (4.41 oz) *Meets EMC and Safety requirements. See the Declaration of Conformity for details.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-68

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-16TD1 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

Dual Power Source

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos

Single Power Source

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring

24VDC

Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-69

DC Output Modules
P3-16TD2
The P3-16TD2 DC Output Module provides sixteen 6-27 VDC sourcing outputs with two isolated commons.
C

Sourcing Output

<--->

Output Specifications

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Terminal Type (not included) Status Indicators Commons

16 (sourcing) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / + 10%) 0.5A / point, 4A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.2 VDC @ 0.5A 2A for 10 ms 1 ms 2 ms 20-position removable terminal block Logic Side (16 points) 2 Isolated (8 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 120g (4.23 oz)

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 5.38W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only.

Removable Terminal Block Specifications


We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems. Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.
Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Volume 13

e7-70

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-16TD2 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-71

DC Output Modules
P3-32TD1
The P3-32TD1 DC Output Module provides thirty-two 6-27 VDC sinking outputs with four isolated commons.
C

Sinking Output

<--->

UL
R

US

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Connector Type Status Indicators Commons External DC Power Required

Output Specifications

32 (sinking) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / +10%) 0.3A / point, 2.4A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.3 VDC @ 0.3A 0.5A for 10 ms 0.2 ms 0.3 ms 40-pin IDC Logic Side (32 points) 4 Isolated (8 points / common) 24VDC 10% @ 250mA

General Specifications
No terminal block sold for this module; ZIPLink required.
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 10.74W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 110g (3.88 oz)

Connector Specifications
Derating Chart
Points

Connector Type Number of Pins Pitch

IDC style header with latch, Omron XG4A-4034 40 point 0.1 in. (2.54 mm)

32

16

0
0 32 10 50 20 68 30 86 40 104 50 60 C 122 140 F

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Ambient Temperature ( C/ F)

See Wiring Systems for part numbers of ZIPLink cables and connection modules required with this I/O module.

Volume 13

e7-72

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-32TD1 (contd)
Wiring Diagrams
Dual Power Source

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders

Single Power Source

Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures

24VDC

Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-73

DC Output Modules
P3-32TD2
Sourcing Output

<--->

The P3-32TD2 DC Output Module provides thirty-two 24 VDC sourcing outputs with four isolated commons.
C

UL
R

US

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Connector Type Status Indicators Commons

Output Specifications

32 (sourcing) 24 VDC (-15% / + 20%) 24 VDC (-20% / + 25%) 0.2A / point, 1.6A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.3 VDC @ 0.2A 0.5A for 10 ms 0.5 ms 0.5 ms 40-pin IDC Logic Side (32 points) 4 Isolated (8 points / common)

General Specifications
No terminal block sold for this module; ZIPLink required.
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 6.69W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 110g (3.88 oz)

Connector Specifications
Connector Type Number of Pins Pitch

IDC style header with latch, Omron XG4A-4034 40 point 0.1 in. (2.54 mm)

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

See Wiring Systems for part numbers of Z IPLink cables and connection modules required with this I/O module.

Volume 13

e7-74

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-32TD2 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-75

DC Output Modules
P3-64TD1
The P3-64TD1 DC Output Module provides sixty-four 6-27 VDC sinking outputs with eight isolated commons.
C

Sinking Output

<--->

UL
R

US

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Connector Type Status Indicators Commons External DC Power Required

Output Specifications

64 (sinking) 6.25 24 VDC (-15% / + 20%) 6 27 VDC (-15% / +10%) 0.1A / point, 0.8A / common @ 60C 0.4 mA 0.3 mA @ 30 VDC 0.3 VDC @ 0.1A 0.5A for 10 ms 0.2 ms 0.3 ms Two 40-pin IDC Logic Side (32 points x 2) 8 Isolated (8 points / common) 24VDC 10% @ 210mA

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

No terminal block sold for this module; ZIPLink required.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 11.35W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 160g (5.64 oz)

Connector Specifications
Connector Type Number of Pins Pitch

Der
Points 64 56 48 40 32 24 16 8 0 0 32 10 50

WARNING: Explosion hazard Substitution of components may


ating Derating Chart
impair suitability for Class I, Division 2.

IDC style header with latch, Omron XG4A-4034 40 point x 2 0.1 in. (2.54 mm)

45 C 113 F

See Wiring Systems for part numbers of ZIPLink cables and connection modules required with this I/O module.

20 68

30 86

40 104

50 60 C 122 140 F

Ambient Temperature ( C/ F)

Volume 13

e7-76

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-64TD1 (contd)
Wiring Diagrams
Dual Power Source

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox

24VDC

24VDC

24VDC

Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors

24VDC

24VDC

24VDC

Single Power Source


24VDC 24VDC 24VDC

Pressure Sensors Temperature Sensors Pushbuttons/ Lights

24VDC 24VDC 24VDC

Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

24VDC

Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-77

DC Output Modules
P3-64TD2
Sourcing Output

<--->

The P3-64TD2 DC Output Module provides sixty-four 24 VDC sourcing outputs with eight isolated commons.
C

UL
R

US

Outputs per Module Operating Voltage Range CE (Tolerance) UL Maximum Output Current @ Temp Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Connector Type Status Indicators Commons

Output Specifications

64 (sourcing) 24 VDC (-15% / + 20%) 24 VDC (-20% / + 25%) 0.1 A / point, 0.8A / common @ 60 C 0.4 mA 0.3 mA @ 30 VDC 0.6 VDC @ 0.1A 0.5A for 10 ms 0.5 ms 0.5 ms Two 40-pin IDC Logic Side (32 points x 2) 8 Isolated (8 points / common)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

No terminal block sold for this module; ZIPLink required.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 11.57W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Use ZIPLink wiring system. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 160g (5.64 oz)

Connector Specifications
Connector Type Number of Pins Pitch

IDC style header with latch, Omron XG4A-4034 40 point x 2 0.1 in. (2.54 mm)

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

See Wiring Systems for part numbers of Z IPLink cables and connection modules required with this I/O module.

Volume 13

e7-78

Programmable Controllers

1 - 80 0 - 633 - 0405

DC Output Modules
P3-64TD2 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors

24VDC

24VDC

24VDC

24VDC

Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights

24VDC

24VDC

24VDC

24VDC

Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-79

AC Output Modules
P3-08TAS
Isolated Output

<--->

The P3-08TAS AC Output Module provides eight 100-240 VAC isolated outputs with eight fused commons.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module 8 Operating Voltage Range (CE) 100 240 VAC (-15% / +10%) (UL) 100 240 VAC (-20% / +20%) (Tolerance) 1A / point @ 40C Maximum Output Current @ Temp 0.7A / point @ 60C AC Frequency 47 - 63 Hz Minimum Load (TYPE 2) 10 mA Maximum Leakage Current (TYPE 2) 4 mA @ 264 VDC On Voltage Drop 1.5 VAC @ > 50 mA 4.0 VAC @ < 50 mA Maximum Inrush Current 10A for 10 ms OFF to ON Response 1 ms + 1/2 cycle ON to OFF Response 1 ms + 1/2 cycle Status Indicators Logic Side (8 points) Error Status Indicator Blown Fuse (one for each point) Terminal Type (not included) 20-position removable terminal block Commons 8 Isolated (1 point / common) Fuses 3.15A user replaceable fuse per common For replacement, order P3-FUSE-1. (Qty. 5/pkg.)

Output Specifications

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 12.46W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 125g (4.41 oz)

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.
Volume 13

e7-80

Programmable Controllers

1 - 80 0 - 633 - 0405

AC Output Modules
P3-08TAS (contd)
Derating Chart
Points

Company Information Systems Overview Programmable Controllers Field I/O Software

8 6 4 2 0

Replaceable Fuses
0.7A 1.0A

Order Part Number P3-FUSE-1 (Qty. 5 per pkg.) One spare included with module.

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos

0 32

10 50

20 68

30 86

40 104

50 60 C 122 140 F

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools

Ambient Temperature ( C/ F)
Current 1.0A 0.7A 8 8 8 8 4 8

0 40 60

Wiring Diagrams

Temp

3.15A

Pneumatics

ZC

Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-81

AC Output Modules
P3-16TA
AC Output

<--->

The P3-16TA AC Output Module provides sixteen 100-240 VAC outputs with two isolated fused commons.
C

UL
R

US

Terminal block sold separately; terminal block cover included with module.

Outputs per Module 16 Operating Voltage Range (CE) 100 240 VAC (-15% / +10%) (UL) 100 240 VAC (-20% / +20%) (Tolerance) AC Frequency 47 - 63 Hz Maximum Output Current @ Temp 0.5A / point , 4A / common @ 60 C (Type 2) Minimum Load (TYPE 2) 10 mA Maximum Leakage Current (TYPE 2) 4 mA @ 264 VDC On Voltage Drop 1.5 VAC @ > 50 mA 4.0 VAC @ < 50 mA Maximum Inrush Current 10A for 10 ms OFF to ON Response 1 ms + 1/2 cycle ON to OFF Response 1 ms + 1/2 cycle Status Indicators Logic Side (16 points) Error Status Indicator Blown Fuse (one for each common) Terminal Type (not included) 20-position removable terminal block Commons 2 Isolated (8 points / common) Fuses 6.3A user replaceable fuse per common For replacement, order P3-FUSE-2. (Qty. 5/pkg.)

Output Specifications

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 12.69W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 125g (4.41 oz)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Removable Terminal Block Specifications


Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.
Volume 13

e7-82

Programmable Controllers

1 - 80 0 - 633 - 0405

AC Output Modules
P3-16TA (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

Order Part Number P3-FUSE-2 (Qty. 5 per pkg.) One spare included with module.

Replaceable Fuses

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights

6.3A

ZC

Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-83

Relay Output Modules


P3-08TRS
Isolated Relay Output

<--->

The P3-08TRS Isolated Relay Output Module provides eight 1.75A relay outputs with eight fused commons and blown fuse indicators.
C

Outputs per Module Operating Voltage Range (Tolerance)

Output Specifications
(CE) (UL)

UL
R

Output type AC Frequency Maximum Output Current @ Temp Minimum Load Current Maximum Inrush Current OFF to ON Response ON to OFF Response Status Indicators Error Status Indicator Terminal Type (not included) Commons Fuses

US

Terminal block sold separately; terminal block cover included with module.

8 6.25 - 24 VDC (-15% / + 20%) 6 - 240 VAC (-15% / + 10%) 6 - 27 VDC (-15% / + 10%) 6 - 240 VAC (-10% / + 10%) Relay, form A (SPST) 47 - 63 Hz 1.75A per point @ 60C for both AC and DC 5 mA @ 5 VDC 4A for 10 ms 10 ms 10 ms Logic Side (8 points) Blown Fuse (one for each point) 20-position removable terminal block 8 Isolated (1 point / common) 3.15A user replaceable fuse per common For replacement, order P3-FUSE-1. (Qty. 5/pkg.)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 3.04W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 135g (4.76 oz)

Typical Relay Life


Voltage & Type of Load 30VDC Resistive 30VDC Solenoid 120VAC Resistive

Load Current 2A 150K 210K 140K 150K 100K 75K

Removable Terminal Block Specifications


Description Wire Range

240VAC Solenoid

240VAC Resistive

120VAC Solenoid

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Screw Driver Width Screw Size Screw Torque

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-84

Programmable Controllers

1 - 80 0 - 633 - 0405

Relay Output Modules


P3-08TRS (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

Replaceable Fuses

Order Part Number P3-FUSE-1. (Qty. 5 per pkg.) One spare included with this module.

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-85

Relay Output Modules


P3-16TR
Relay Output

<--->

The P3-16TR Relay Output Module provides sixteen 1.25A relay outputs with two isolated fused commons.
UL
R

Outputs per Module Operating Voltage Range (Tolerance)

Output Specifications
(CE) (UL)

Output type AC Frequency Maximum Output Current @ Temp Minimum Load Current Maximum Inrush Current OFF to ON Response ON to OFF Response Status Indicators Error Status Indicator Terminal Type (not included) Commons per module Fuses

US

Terminal block sold separately; terminal block cover included with module.

16 6.25 - 24 VDC (-15% / + 20%) 6 - 240 VAC (-15% / + 10%) 6 - 27 VDC (-15% / + 10%) 6 - 240 VAC (-10% / + 10%) Relay, form A (SPST) 47 - 63 Hz 1.25A / point, 6.3A / common @ 60C for both AC and DC 5 mA @ 5 VDC 4A for 10 ms 10 ms 10 ms Logic Side (16 points) Blown Fuse (one for each common) 20-position removable terminal block 2 Isolated (8 point / common) 6.3A user replaceable fuse per common For replacement, order P3-FUSE-2. (Qty. 5/pkg.)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

Typical Relay Life


Voltage & Type of Load 30VDC Resistive 30VDC Solenoid 120VAC Resistive

Load Current 1.25A 240K 110K 320K 210K 240K 140K

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1500VAC applied for 1 minute >10M @ 500 VDC 3.93W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 160g (5.64 oz)

120VAC Solenoid 240VAC Solenoid

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

240VAC Resistive

Removable Terminal Block Specifications


Description Wire Range

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Volume 13

e7-86

Programmable Controllers

1 - 80 0 - 633 - 0405

Relay Output Modules


P3-16TR (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

C1 1 3 5 7 C2 9 11 13 15

Order Part Number P3-FUSE-2. (Qty. 5 per pkg.) One spare included with this module.

Replaceable Fuses

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-87

Relay Output Modules


P3-08TRS-1
The P3-08TRS-1 High-Current Isolated Relay Output Module provides eight 5A relay outputs with eight fused commons.
C

Isolated Relay Output

<--->

UL
R

US

Terminal block sold separately; terminal block cover included with module.

8 relays (non-latching) 8 (isolated) (CE) 6.25-24 VDC (-15% / +20%) 6-240 VAC (-15% / +10%) (UL) 5-30 VDC (-0% / +10%) 5-240 VAC (-0% / +10%) Output Type 4 Form C (SPDT-NO/NC), 4 Form A (SPST-NO) AC Frequency 47-63 Hz On Voltage Drop Minimal (90 mV max for fuse at 10A) Max Output Current 6.3A at 23C, 5.0A at 60C @ Temperature (Resistive)* For both AC and DC Maximum Leakage Current Minimal (5 A for TVS diode) Minimum Load 10 mA @ 5 VDC Maximum Inrush Current 12A External DC Required None OFF to ON Response 10 ms ON to OFF Response 5 ms (Excluding NO bounce) Terminal Type (not included) 20-position removable terminal block Status Indicators Logic side Fuses 6.3A user replaceable fuse per common For replacement, order P3-FUSE-2 (5/Pkg.) Dielectric Strength (Between nor- 1500 VAC @ 1 min logic to output and mally open and normally closed isolated output to output, 750 VAC @ 1 min contacts on the same relay) between contacts on same relay (Same as 1800 VAC @ 1 sec and 900 VAC @ 1 sec) Transient Voltage Suppression 482V clamp at 1.25A peak pulse current (Bi-directional TVS diode) Mechanical Life Expectancy >100,000 at 30 operations per minute *Rating is for a normally-open conact. Normally-closed contacts have 1/2 the current handling capability.

Outputs per Module Commons per Module Operating Voltage Range (Tolerance)

Output Specifications

Amps
8 6 4 2 0 0 32

Output Derating

*Ratings are for normally-open conacts. Normally-closed contacts have 1/2 the current handling capability.

Voltage & Type of Load 24VDC Resistive 24VDC Solenoid 120VAC Resistive 120VAC Resistive 120VAC Solenoid 240VAC Resistive 240VAC Resistive 1/4 HP Motor

Typical Relay Life*

Operating Current 6.3A 0.2A 6.3A 3A 0.5A 6.3A 3A 1.5 x FLA (motor)

Operations 600,000 1,000,000 600,000 1,000,000 500,000 450,000 600,000 30,000

Removable Terminal Block Specifications


Description Wire Range

10 20 30 40 50 50 68 86 104 122 Ambient Temperature ( C/ F)

60 C 140 F

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

All 8 outputs on, 100% duty cycle allowed.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Volume 13

e7-88

Programmable Controllers

1 - 80 0 - 633 - 0405

Relay Output Modules


P3-08TRS-1 (contd)
0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 3W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 286g (10.08 oz)

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

Replaceable Fuses

Order Part Number P3-FUSE-2 (Qty. 5/Pkg.) One spare included with this module.

F7

F8 F6

F5 F4

F3 F2

F1

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

5-30VDC 5-240VAC

C1

L
C2

NO1 NO2 C3 NO3 C4 NO4 NC5 C5 NO5 NC6 C6 NO6 NC7 C7 NO7 NC8 C8 NO8

L L L L L L L L L L L

Outputs NO1 NO4

5-30VDC = 5-240VAC

COM

Internal module circuitry 6.3A

Pushbuttons/ Lights Process

L
NO
5-30VDC = 5-240VAC

Relays/ Timers Comm. Terminal Blocks & Wiring Power

Outputs NO5 / NC5 NO8 / NC8

Internal module circuitry COM 6.3A

L L

NO NC

Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-89

Analog Input Modules


P3-04ADS
The P3-04ADS Isolated Voltage/Current Analog Input Module provides four isolated channels for receiving 10 VDC, 0 to 5 VDC, 0 to 10 VDC and 0 to 20mA signals.
C

Isolated Voltage/Current Analog Input

<--->

Input Specifications
Input Channels Module Signal Input Ranges

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Terminal block sold separately; terminal block cover included with module.

4 Channel-to-Channel Isolated 10VDC, 0 - 5 VDC, 0 - 10 VDC, 0 - 20 mA Resolution 15 bit + sign Value of LSB (least significant bit) 10V = 305 V, 16 bit 0-5V = 152 V, 14 bit 0-10V = 305 V, 15 bit 0-20mA = 0.610 A, 14 bit Data Range 0 to 65535 counts unipolar -32768 to +32767 counts bipolar Isolated Loop Pwr for Ext. Xmitters 20-30VDC, current limited to < 30 mA Input Type Differential Common Mode Rejection Ratio -75 dB min. @ DC, -500 kHz Maximum Continuous Overload 31 mA. , current input 100V, voltage input Input Impedance 205k V 5% voltage input 250 V 0.1% W. current input Filter Characteristics Active low pass, -3dB @ 30Hz, -10dB @ 55Hz Sample Duration Time 1.28 ms per channel (does not include ladder scan time) All Channel Update Rate 5.2 ms Open Circuit Detection Time Zero reading within 1s Conversion Method Successive Approximation Accuracy vs. Temperature 25 PPM / C max Maximum Inaccuracy 0.1% of range voltage, 0.2% of range current (including temperature drift) Linearity Error (End to End) 0.025% of range maximum, Monotonic with no missing codes Input Stability and Repeatability 0.02% of range maximum after 10 min. Full Scale Calibration Error 0.05% of range maximum (not including Offset) Offset Calibration Error 0.05% of range maximum Max Crosstalk -96 dB 1 LSB Channel to Channel Isolation 900 VDC applied for 1 second Recommended Fuse (external) Edison S500-32-R, 0.032A fuse on current inputs only External DC Power Required NONE for the module

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.
Volume 13

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VAC applied for 1 second >10M @ 500 VDC 2.6 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 61g (2.14 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

e7-90

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-04ADS (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

INTERNAL MODULE CIRCUITRY


CH1 ADC ISOLATED ANALOG INPUT CH2 ADC ISOLATED ANALOG INPUT

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls

V1+ V2+ V1V2I1+ I2+ I1I2-

V3+ V4+ V3V4I3+ I4+ I3I4-

CH3 ADC ISOLATED ANALOG INPUT CH4 ADC ISOLATED ANALOG INPUT

Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights

Unused Circuits V+

An Edison S500-32-R 0.032A fast-acting fuse is recommended for all 4-20mA current loops.

Current Input Circuits

Process Relays/ Timers

V
fuse

Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics

Jumper unused circuits as shown

V-

2-Wire 4-20 mA Transmitter

.032A

I+ I-

2-Wire Transmitter Voltage Input Circuits V+


4-Wire Voltage Transmitter
Optional Transmitter Power Supply

Transmitter Power Supply

Optional Transmitter Power Supply

+
3-Wire 4-20 mA Transmitter

VI+ I-

V-

fuse

.032A

AC or DC

4-Wire Transmitter
NOTES: 1. Shield connected to signal source common. 2. If current is chosen, I- MUST be jumpered to V-. For example, when using 4-20 mA source for Input 3, I3- must be connected to V3-.

3-Wire Transmitter
Optional Transmitter Power Supply

AC or DC

VI+ I-

Appendix Product Index Part # Index

4-Wire Current Transmitter

.032A
fuse

4-Wire Transmitter

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-91

Analog Input Modules


P3-08AD
Voltage/Current Input

<--->

The P3-08AD Voltage/Current Analog Input Module provides 8 channels for receiving 10 VDC, 5 VDC, 0 to 5 VDC, 0 to 10 VDC, and 0 to 20mA signals.
C

Input Channels Module Signal Input Ranges Signal Resolution Resolution Value of LSB (least significant bit)

Input Specifications

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Maximum Continuous Overload Input Impedance Hardware Filter Characteristics Sample Duration Time All Channel Update Rate Open Circuit Detection Time Conversion Method Accuracy vs. Temperature Maximum Inaccuracy Linearity Error (end to end)

Data Range

Terminal block sold separately; terminal block cover included with module.

Input Stability and Repeatability Full Scale Calibration Error (not including offset) Offset Calibration Error Max Crosstalk Recommended Fuse (external) External DC Power Required

0 to 65535 counts unipolar -32768 to +32767 counts bipolar 31mA, current input 100V, voltage input 1M 10% voltage input 250 0.1% 1/4W. current input Low pass 1st order, -3dB@48Hz 455s per channel (does not include ladder scan time) 4ms Zero reading within 1s (current input only) Successive Approximation 10PPM / C Maximum 0.1% of range voltage, 0.2% of range current (including temperature drift) 0.01% of range max., 10V & 5V 0.015% of range max., 0-10V, 0-5V & 0-20mA Monotonic with no missing codes 0.035% of range (after 10 min. warmup) 0.1% of range maximum .065% of range maximum -96dB Edison S500-32-R, .032A fuse on current inputs only 24VDC (-20% / + 25%) 33mA

8 10VDC, 5VDC, 0 - 5VDC, 0 - 10VDC, 0 - 20mA 16 bit 1 LSB = 1 count 10V = 305V 5V = 152V 0 - 5V = 76V 0 - 10V = 152V 0 - 20mA = 0.305A

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VAC applied for 1 second >10M @ 500 VDC 1.1 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-92

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-08AD (contd)
Wiring Diagrams
Current Sinking Input Circuits
An Edison S500-32-R 0.032A fast-acting fuse is recommended for all current loops.
V+
fuse

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches
V+

INTERNAL MODULE CIRCUITRY


V1+ V2+ I1+ I2+ V3+ V4+ I3+ I4+ COM COM V5+ V6+ I5+ I6+ V7+ V8+ I7+ I8+ 24VDC24VDC+ + ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON CH7 ADC CH8 ADC CH5 ADC CH6 ADC CH3 ADC CH4 ADC CH1 ADC CH2 ADC

2-Wire 4-20 mA Transmitter


+

.032A

I+ COM

2-Wire Transmitter
+ 3-Wire Current + Transmitter

fuse

.032A

3-Wire Transmitter

24VDC User Supplied Power V+

4-Wire 4-20 mA Transmitter AC or DC

+ User Supplied Transmitter Power

fuse

.032A

4-Wire Transmitter

Voltage Input Circuits


4-Wire Voltage Transmitter
Optional Transmitter Power Supply COM

AC or DC

4-Wire Transmitter
V+ COM

3-Wire Transmitter

24 VDC User Supplied Power

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

24 VDC User Supplied Power

3-Wire Voltage + Transmitter

Power Supply I+ V+ COM

I+ COM

Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Volume 13

e7-93

Analog Input Modules


P3-16AD-1
The P3-16AD-1 Current Analog Input Module provides sixteen channels for receiving current sinking 0 to 20mA input signals.
C

Current Analog Input

<--->

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Input Channels Module Signal Input Range Signal Resolution Resolution Value of LSB (least significant bit) Data Range Input Type Maximum Continuous Overload Input Impedance Filter Characteristics Sample Duration Time All Channel Update Rate Open Circuit Detection Time Conversion Method Accuracy vs. Temperature Maximum Inaccuracy Linearity Error (end to end)

Input Specifications

Input Stability and Repeatability Full Scale Calibration Error (not including offset) Offset Calibration Error Max Crosstalk Recommended Fuse (external) External DC Power Required

16 sinking 0 - 20mA 16 bit 0-20mA = 305A per count (1 LSB = 1 count) 0-65535 counts Single-ended (1 common) 31mA 250 0.1% W Low Pass, -3dB @ 100Hz 7 ms per channel (does not include ladder scan time) 112 ms Zero reading within 1s Successive approximation 25PPM / C maximum 0.1% of range (including temperature drift) 10 LSB maximum (0.015% of range) Monotonic with no missing codes 10 LSB 10 LSB maximum (0.015% of range) 10 LSB maximum -76 dB, 10 LSB Edison S500-32-R, .032A fuse 24VDC (-20% / + 25%) 20mA

Terminal block sold separately; terminal block cover included with module.

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 2.1 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-94

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-16AD-1 (contd)
Wiring Diagrams
Current Input Circuits

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives

INTERNAL MODULE CIRCUITRY


I1+ I2+ I3+ I4+ I5+ I6+ I7+ I8+ COM COM I9+ I10+ I11+ I12+ I13+ I14+ I15+ I16+ 24VDC24VDC+ + CH9 ADC CH10 ADC CH11 ADC CH12 ADC CH13 ADC CH14 ADC CH15 ADC CH16 ADC ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON CH1 ADC CH2 ADC CH3 ADC CH4 ADC CH5 ADC CH6 ADC CH7 ADC CH8 ADC

An Edison S500-32-R 0.032A fast-acting fuse is recommended for current loops.

fuse

2-Wire 4-20 mA Transmitter


+

.032A + +24VDC User Supplied Power

I+

Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls

2-Wire Transmitter

COM

+ 3-Wire Current Transmitter + +

fuse

.032A

I+

Proximity Sensors Photo Sensors Limit Switches Encoders

+24VDC User Supplied Power COM

3-Wire Transmitter

4-Wire 4-20 mA Transmitter AC or DC

+ User Supplied Transmitter Power

fuse

.032A

I+ COM

Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

4-Wire Transmitter
Note: Do not connect both ends of shield.

24 VDC User Supplied Power

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-95

Analog Input Modules


P3-16AD-2
Voltage Analog Input

<--->

The P3-16AD-2 Voltage Analog Input Module provides sixteen channels for receiving 0 to 10 VDC signals.
C

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Input Channels Module Signal Input Range Signal Resolution Resolution Value of LSB (least significant bit) Data Range Input Type Maximum Continuous Overload Input Impedance Filter Characteristics Sample Duration Time All Channel Update Rate Open Circuit Detection Time Conversion Method Accuracy vs. Temperature Maximum Inaccuracy Linearity Error (end to end)

Input Specifications

Input Stability and Repeatability Full Scale Calibration Error (not including offset) Offset Calibration Error Max Crosstalk External DC Power Required

16 0 - 10 VDC 16 bit 0 - 10 VDC = 152 V per count (1 LSB = 1 count) 0 to 65535 counts Single-ended (one common) 100V 250K (typical) Low Pass, -3dB @ 100Hz 7 ms per channel (does not include ladder scan time) 112 ms Zero reading within 1s Successive approximation 25 PPM / C Maximum 0.1% of range (including temperature drift) 10 LSB maximum (0.015% of range) Monotonic with no missing codes 10 LSB 10 LSB maximum (0.015% of range)

10 LSB maximum -76 dB, 10 LSB 24 VDC (-20% / + 25%), 41mA maximum

Terminal block sold separately; terminal block cover included with module.

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VAC applied for 1 second >10M @ 500 VDC 1.4 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Volume 13

e7-96

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-16AD-2 (contd)
Wiring Diagrams

Company Information Systems Overview Programmable Controllers Field I/O Software

INTERNAL MODULE CIRCUITRY


V1+ V2+ V3+ V4+ V5+ V6+ V7+ V8+ COM COM V9+ V10+ V11+ V12+ V13+ V14+ V15+ V16+ 24VDC24VDC+ + CH9 ADC CH10 ADC CH11 ADC CH12 ADC CH13 ADC CH14 ADC CH15 ADC CH16 ADC ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON

Voltage Input Circuits


CH1 ADC CH2 ADC CH3 ADC CH4 ADC CH5 ADC CH6 ADC CH7 ADC CH8 ADC

C-more & other HMI Drives

V+

4-Wire Voltage Transmitter

Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls

COM

AC or DC

4-Wire Transmitter

Transmitter Power Supply

+
3-Wire Voltage + Transmitter

V+ COM

Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

3-Wire Transmitter

24 VDC User Supplied Power

24 VDC User Supplied Power

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

+
Volume 13

e7-97

Analog Input Modules


P3-08RTD
RTD Analog Input

<--->

RTD Input Specifications


Input Channels Max. Common Mode Voltage Data Format Common Mode Rejection Absolute Maximum Ratings Internal Resolution Input Ranges (RTD Types)

The P3-08RTD input module provides eight differential channels for receiving RTD and resistance input signals.
C

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

RTD Linearization Excitation Current (all ranges) Accuracy vs. Temperature Full Scale Calibration Offset Calibration Error Linearity Error (end to end) Maximum Inaccuracy

Warm-up Time Sample Duration (Single channel update rate) Filter Characteristics

All Channel Update Rate

Terminal Block P3-RTB and Cover included. Not compatible with ZIPLink.

Open Circuit Detection Time Conversion Method External DC Power Required

2 minutes for 0.2% repeatability Dependent on Digital Filter Settings -488ms @ 10Hz, 88ms @ 50 Hz, 75ms @ 60Hz, 56ms @ 100Hz, 48ms @ 250Hz Digital filter cutoff frequencies: 10Hz, 50Hz, 60Hz, 100Hz, or 250Hz Single channel update rate times the number of enabled channels Positive full scale reading within 2s Sigma-Delta None

8 Differential 5VDC Floating Point -90dB min. @ DC, -150dB min. @ 50/60Hz Fault protected input, 50V 16 bit, 0.1C or F (up to 100 Hz filter) Pt100 -200C/850C (-328F/1562F) Pt1000 -200C/595C (-328F/1103F) JPt100 -100C/450C (-148F/ 842F) 10 Cu. -200C/260C (-328F/ 500F) 25 Cu. -200C/260C (-328F/ 500F) 120 Ni. -80C/260C (-112F/ 500F) Automatic 200A 5ppm per C (maximum) 1C 1 count (negligible) 0.5C maximum, 0.01C typical, Monotonic with no missing codes 1C maximum (excluding RTD error) (including temperature drift)

Resistance Input Specifications


Resistance Input Ranges and PAC Resolution Internal Resolution

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Accuracy vs. Temperature Full Scale Calibration Offset Calibration Error Linearity Error (end to end) Maximum Inaccuracy

16 bit, .0015% of full scale range in ohms (up to 100Hz filter) 0-10,000 , Resolution 1 0-6,250 , Resolution 0.1 0-3,125 , Resolution 0.1 0-1,562.5 , Resolution 0.1 0-781.25 , Resolution 0.1 0-390.625 , Resolution .01 0-195.3125 , Resolution .01 25ppm per C (maximum) .02% of full scale range .0015% of full scale range in ohms .0015% of full scale range maximum at 25C, Monotonic with no missing codes 0.10% of full scale range

Diagnostics

Module Diagnostics Failure Module Not Ready Channel Burn-out (RTD only) Under-range (RTD only) Over-range

1 1 1 1 1

bit bit bit bit bit

per per per per per

module module channel channel channel

Volume 13

e7-98

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-08RTD (contd)
0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 0.33 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (included). The P3-08RTD module is not compatible with the ZIPLink wiring system. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type 20-position removable terminal block (included) 107.8g (3.79 oz) Weight

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.
INTERNALMODULE CIRCUITRY
R1+ R1R2+ R2COM COM R3+ R3R4+ R4R5+ R5R6+ R6COM COM R7+ R7R8+ R8CH7 RTD INPUT CH8 RTD INPUT CH3 RTD INPUT CH4 RTD INPUT CH5 RTD INPUT CH6 RTD INPUT CH1 RTD INPUT CH2 RTD INPUT

Resistance Input
R+

RTD Input Circuits


2-wire RTD
R+ RCOM Note: Connect two wires to one side of a 2-wire RTD.

Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

RCOM

3-wire RTD

R+

RCOM

4-wire RTD

R+

RNote: Leave 4th wire unattached as shown. COM

ANALOG CIRCUIT COMMON

Notes for maximum accuracy: 1. For 2-wire RTD, attach third wire to module common. 2. R+, R-, and COM wires to an RTD must be equal length and type. Refer to RTD manufacturers recommendations. 3. Do not use cable shield as sensing wire. 4. When applicable, connect shield to RTD common only, otherwise connect to module common only. Do not connect shield to both ends. R+ 5. Jumper unused inputs to common.
RCOM

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-99

Analog Input Modules


P3-08THM
The P3-08THM Thermocouple Input Module provides eight differential channels for receiving thermocouple and voltage input signals.
C

Thermocouple Analog Input

<--->

UL
R

US

Input channels Data Format Common Mode Range Common Mode Rejection Input Impedance Maximum Ratings Resolution Thermocouple Input Ranges

T/C Input Specifications

Patent-pending LCD gives access to field signal values, as well as module and signal faults.
Cold Junction Compensation Thermocouple Linearization Accuracy vs. Temperature Linearity Error Maximum Inaccuracy Warm-up Time

8 differential Floating point 1.25V 100dB @ DC and 130dB @ 60Hz >5M ohms Fault-protected inputs to 50VDC 16-bit, 0.1C or F Type J -190 to 760C (-310 to 1400F); Type E -210 to 1000C (-346 to 1832F); Type K -150 to 1372C (-238 to 2502F); Type R 65 to 1768C (149 to 3214F); Type S 65 to 1768C (149 to 3214F); Type T -230 to 400C (-382 to 752F); Type B 529 to 1820C (984 to 3308F); Type N -70 to 1300C (-94 to 2372F); Type C 65 to 2320C (149 to 4208F); Automatic Automatic 50PPM / C Maximum 1C Maximum (0.5C typical), Monotonic with no missing codes 3C Max (excluding thermocouple error) (including temperature drift) 30 Minutes for 1C Repeatability 2 minutes to reach voltage specifications 270ms 2.16s Within 2s Sigma-Delta NONE

Terminal Block P3-RTB and Cover included. Not compatible with ZIPLink.

Sample Duration Time All Channel Update Rate Open Circuit Detection Time Conversion Method External DC Power

Linear mV Device Input Ranges

Voltage Input Specifications

Max Max Max Max

Voltage Voltage Voltage Voltage

Input Input Input Input

Offset Error Gain Error Linearity Error Inaccuracy

0-39.0625 mVDC, +/-39.0625 mVDC, +/-78.125 mVDC, 0-156.25 mVDC, +/-156.25 mVDC, 0-1250 mVDC 0.05% @ 0 - 60C, typical 0.04% @ 25C 0.06% @ 25C 0.05% @ 0 - 60C, typical 0.03% @ 25C 0.2% @ 0 - 60C, typical 0.06% @ 25C

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

* Use shielded, twisted themocouple wire that matches the thermocouple type.

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent.* 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Configuration/Diagnostics

Burn-out Detection Enable/Disable C/F (T/C only) Module Diagnostics Failure Burn-out (on if T/C input is open no connection between TCn+ and TCn-) Channel Under-range (T/C only) Channel Over-range (T/C only)

1-bit per module 1 bit per module 1 bit per module

1 bit per channel 1 bit per channel 1 bit per channel

Volume 13

e7-100

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input Modules


P3-08THM (contd)
0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 0.36 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (included). The P3-08THM module is not compatible with the ZIPLink wiring system. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type 20-position removable terminal block (included) Weight 150g (5.3 oz)

Company Information Systems Overview Programmable Controllers Field I/O


TC1+ TC1TC2+ TC2CH1 mV INPUT CH2 T/C INPUT

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors

INTERNAL MODULE CIRCUITRY


TC3+ TC3TC4+ TC4TC5+ TC5TC6+ TC6CH3 T/C INPUT CH4 T/C INPUT CH5 T/C INPUT CH6 T/C INPUT

TC7+ TC7TC8+ TC8-

CH7 T/C INPUT CH8 T/C INPUT

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Thermocouple Input Circuits


Ungrounded/Shielded Thermocouple
TC+ TC-

Voltage Input Circuits


4-wire Voltage Transmitter
AC or DC TC+ TC-

Pressure Sensors Temperature Sensors Pushbuttons/ Lights

Transmitter Power Supply

Grounded/Shielded Thermocouple

TC+ TC-

Load Cell or Strain Gauge


AC or DC

TC+ TC-

Process Relays/ Timers Comm.

Excitation Power Supply Voltage Divider

Infrared Thermocouple

TC+ TC-

TC+ TC-

Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

NOTES: 1. Connect shield to thermocouple signal/ground only. Do not connect to TC+ both ends. 2. Install jumper wire on each unused input, TCTC+ to TC-. 3. With grounded thermocouples, take precautions to prevent having a voltage potential between thermocouple tips. A voltage of 1.25V or greater between tips will skew measurements. 4. Use shielded, twisted thermocouple extension wire that matches the thermocouple type. Use thermocouple-compatible junction blocks.

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-101

Analog Output Modules


P3-04DA
The P3-04DA Voltage/Current Analog Output Module provides four channels of 10 VDC or 4 - 20mA sink/source selectable outputs.
C

Voltage/Current Analog Output

<--->

Output Specifications
Output Channels Module signal output range Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output Type

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Output Value in Fault Mode Load Impedence (Minimum External Power Supply) Maximum Capacitive Load Maximum Inductive Load Allowed Load Type Maximum Inaccuracy (% of range) Maximum Full Scale Calibration Error (not including offset error) Accuracy vs. Temperature Max Crosstalk Linearity Error (End to End) Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection

4 10V or 4-20mA sink or source selectable each channel 16-bit 10V = 305V/ count 4-20mA = 0.244A/ count 1 LSB = 1 count 0 - 65535 counts uni-polar and -32768 to +32767 counts bi-polar Voltage outputs sourcing/sinking at 10mA max, or Current outputs sink or source at 20mA max. Voltage outputs 0V or 0mA current outputs >1000 voltage outputs )(19.2 - 30 VDC) 0-755 Sinking, 0-600 Sourcing (19.2 VDC) 0-875 Sinking, 0-700 Sourcing (21.6 VDC) 0-1000 Sinking, 0-855 Sourcing (24.0 VDC) 0-1110 Sinking, 0-970 Sourcing (26.4 VDC) 0-1350 Sinking, 0-1150 Sourcing (30 VDC) .01F maximum voltage outputs 1 mH maximum current outputs Grounded 0.1% voltage, 0.1% current (including temperature drift) .025% of range maximum voltage outputs .025% of range maximum current outputs 25 ppm/ C max f.s. calibration change ( .0025% of range / C) -80 dB, 6 LSB 16 LSB maximum (0.025% of full scale) Monotonic with no missing codes 10 LSB after 10 minute warm-up (typical)

Terminal block sold separately; terminal block cover included with module.

Output Signal (power-up, down) External DC Power Required

.05% of Full Scale 0.3 ms max, 5 s min (full scale change) 0.6ms Voltage Outputs current limited to 35mA typical. Current Outputs open circuit protected 15VDC Peak Output Voltage Current outputs current limited to <=20mA 0V voltage outputs, 0mA current outputs 94mA voltage operation 4 channels 126mA current operation 4 channels 24VDC -20% / + 25%

Removable Terminal Block Specifications


We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.
Description Wire Range

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Volume 13

e7-102

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-04DA (contd)
General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals 0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10MV @ 500 VDC 2.6 W voltage outputs 3.4 W current outputs Open Equipment UL508 file E157382, Canada & USA CE (EN61131-2*)

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process
I+ COM

UL1604 file E200031, Canada & USA

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only.

INTERNAL MODULE CIRCUITRY

V1+ COM I1 I1+ V2+ COM I2 I2+ 24VDC+ 24VDC+ V3+ COM I3 I3+ V4+ COM I4 I4+ 24VDC 24VDC+ + -

voltage sink/source CH1 DAC


0 - 10 VDC Load

Voltage Output

Current Source Output


(Field device is sinking)

4-20 mA current sinking 4-20 mA current sourcing voltage sink/source

V+ COM 4 - 20mA Load 24 VDC User Supplied Power + + -

Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures

4-20 mA current sinking 4-20 mA current sourcing

CH2 DAC

AC or DC

I-

V+ 10 VDC Load COM

4-wire 4 - 20mA Load

I+ COM

voltage sink/source
AC or DC

AC or DC Transmitter Power Supply

I-

4-20 mA current sinking 4-20 mA current sourcing voltage sink/source

CH3 DAC

24 VDC User Supplied Power

Current Sink Output


(Field device is sourcing)
+24VDC User Supplied Power ICOM I+

4-20 mA current sinking 4-20 mA current sourcing

CH4 DAC

2-wire 4 - 20mA Load

Tools Pneumatics Appendix Product Index Part # Index

NOTE: Shield is connected to common at the source device.

Install Jumper

ANALOG CIRCUIT POWER

24 VDC User Supplied Power ANALOG CIRCUIT COMMON

4-wire 4 - 20mA Load Install Jumper

24VDC+ ICOM I+

AC or DC Transmitter Power Supply

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-103

Analog Output Modules


P3-08DA-1
Current Analog Output

<--->

The P3-08DA-1 Current Analog Output Module provides eight channels of 4 to 20mA sourcing outputs.
C

UL
R

US

Output Channels (commons) Module Signal Output Range Output Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output Type (sourcing) Output Value in Fault Mode Load Impedence

Output Specifications

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (end to end)

Maximum Inductive Load Allowed Load Type Maximum Inaccuracy

8 4-20mA 16-bit 4-20mA = 0.244A / count 1 LSB = 1 count 0 to 65535 counts Current: 20mA max Near 0mA 0-570 (19.2 VDC) 0-690 (21.6 VDC) 0-810 (24.0 VDC) 0-930 (26.4 VDC) 0-1100 (30.0 VDC) Minimum Load 0 @ 0-45C 125 @ 45-60C 1 mH Grounded 0.1% of range (including temperature drift) .025% of range maximum

Terminal block sold separately; terminal block cover included with module.

Output Stability and Repeatability Output Ripple Output Settling Time All channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal at Power-up and Power-down External DC Power Required

.025% of range maximum 25 ppm/ C maximum full-scale calibration change ( .0025% of range / C) -96 dB, 1 LSB 16 LSB maximum (0.025% of full scale) monotonic with no missing codes 10 count after 10 min. warm-up (typical) .05% of full scale 0.3 ms max, 5 s min (full scale change) 0.6 ms Outputs open circuit protected Electronically current limited to 20mA or less 4 mA 24VDC (-20% / + 25%), 180mA

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

impair suitability for Class I, Division 2.


Volume 13

WARNING: Explosion hazard Substitution of components may

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 4.7 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

e7-104

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-08DA-1 (contd)
FIELD WIRING INTERNAL MODULE CIRCUITRY

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI

I1+ I2+ I3+ I4+ I5+ I6+ I7+ I8+


COM COM COM COM

4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing

CH1 DAC CH2 DAC CH3 DAC CH4 DAC CH5 DAC CH6 DAC CH7 DAC CH8 DAC
Note: Shield is connected to common at the source device. 4 - 20mA Load

Current Source Output Circuit

Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors

24VDC24VDC+ + ISOLATED ANALOG CIRCUIT POWER

Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

24 VDC User Supplied Power ISOLATED ANALOG CIRCUIT COMMON

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-105

Analog Output Modules


P3-08DA-2
The P3-08DA-2 Voltage Analog Output Module provides eight channels of 10 VDC sinking/sourcing outputs.
C

Voltage Analog Output

<--->

Output Channels Module Signal Output Range Output Signal Resolution Resolution Value of LSB (least significant bit)

Output Specifications

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (End to End)

Data range Output Type (sourcing/sinking) Output Value in Fault Mode Load Impedance Maximum Capacitive Load Allowed Load Type Maximum Inaccuracy

8 10VDC 16-bit 10V = 305v/count 1 LSB = 1 count

Terminal block sold separately; terminal block cover included with module.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate (typical) Maximum Continuous Overload Type of Output Protection Output Signal (power-up, -down) External DC Power Required

.025% of range maximum 25 ppm/ C maximum full scale calibration change ( .0025% of range / C) -96 dB, 1 LSB 16 LSB maximum (0.025% of full scale) Monotonic with no missing codes 10 LSB after 10 min. warm-up (typical) .05% of full-scale 0.3 ms max, 5 s min (full scale change) 0.6ms Outputs current limited to 40mA typical Continuous overloads on multiple outputs can damage the module. 0.1f Transient Suppressor 0V 24VDC (-20% / + 25%), 120mA

-32768 to +32767 Voltage (10mA max current) 0V 1000 .01F maximum Grounded 0.1% of range (including temperature drift) .025% of range maximum

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VAC applied for 1 second >10M @ 500 VDC 3.3 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

Volume 13

e7-106

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-08DA-2 (contd)
INTERNAL MODULE CIRCUITRY

Company Information Systems Overview Programmable Controllers Field I/O

Voltage Output Circuits


V+

Software C-more & other HMI Drives Soft Starters Motors & Gearbox
V+

V1+ V2+ V3+ V4+ V5+ V6+ V7+ V8+ COM COM COM COM

voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source

CH1 DAC CH2 DAC CH3 DAC CH4 DAC CH5 DAC CH6 DAC CH7 DAC CH8 DAC

0 - 10 VDC Load

COM

AC or DC Power Supply

10 VDC Load

COM

Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Load Power Supply

V+ -10 - 0 VDC Load COM

Load Power Supply

24VDC24VDC+ + ISOLATED ANALOG CIRCUIT POWER

24 VDC User Supplied Power ISOLATED ANALOG CIRCUIT COMMON

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-107

Analog Output Modules


P3-06DAS-1
Isolated Current Analog Output

<--->

The P3-06DAS-1 Current Analog Output Module provides six channel-to-channel isolated 4-20mA outputs.
C

Output channels (commons) Module Signal Output Range Signal Resolution Resolution Value of LSB (least significant bit)

Output Specifications

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Data Range Output Type (sourcing) Channel to AUX Power Isolation Channel to Channel Isolation Output Value in Fault Mode Load Impedance Maximum Inductive Load Allowed Load Type Maximum Inaccuracy Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature

6 (6 isolated) 4-20mA 16-bit 4-20mA = 0.244A/count 1 LSB = 1 count

Terminal block sold separately; terminal block cover included with module.

.065% of range maximum 25 ppm/ C maximum full scale calibration change ( 0.0025% of range / C) Max Crosstalk (DC, 50 Hz, 60 Hz) -96 dB, 1 LSB** Linearity Error (end to end) 16 LSB maximum (0.025% of full scale) monotonic with no missing codes Output Stability and Repeatability 16 LSB after 10 min. warm-up (typical) Output Settling Time 0.3 ms maximum, 5 s minimum (full scale change) All Channel Update Rate 0.6 ms Type of Output Protection Electronically current limited to 20mA or less Output Signal (power-up, -down) Less than or equal to 4mA*** External DC Power Required 24 VDC (-20% / + 25%), 250mA **To achieve maximum crosstalk per spec, isolation must be maintained, all commons have to be separated *Module generates isolated loop power for each channel

0 to 65535 counts Current: 20mA max (isolated)* 1800VDC applied for 1.8 second (100% tested) 900VDC applied for 1.8 second (100% tested) Less than 4mA 0-750 1mH Floating or Grounded 0.1% of range .065% of range maximum

***Less than 4mA, if the module is not configured or in the RESET stage

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VDC applied for 1.8 seconds (100% tested) >10M @ 500 VDC 3.38 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 108.8g (3.82 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

Volume 13

e7-108

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-06DAS-1 (contd)
INTERNAL MODULE CIRCUITRY
CH1 DAC ISOLATED ANALOG OUPUT CH2 DAC ISOLATED ANALOG OUPUT CH3 DAC ISOLATED ANALOG OUPUT CH4 DAC ISOLATED ANALOG OUPUT CH5 DAC ISOLATED ANALOG OUPUT CH6 DAC ISOLATED ANALOG OUPUT
Current Output Circuits

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls
NOTES: 1. Shield connected to signal source common. 2. Isolated analog outputs can work with sinking and sourcing field devices.

I1+ I2+ I1 I2 Unused Unused I3+ I4+ I3 I4 Unused Unused I5+ I6+ I5 I6 Unused Unused 24VDC 24VDC+ + -

+
4-20 mA Load

Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

MODULE POWER SUPPLY

24 VDC User Supplied Power

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-109

Analog Output Modules


P3-06DAS-2
Isolated Voltage Analog Output

<--->

The P3-06DAS-2 Voltage Analog Output Module provides six channel-to-channel isolated 10 VDC outputs.
C

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Output channels Module Signal Output Range Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output Type (sourcing/sinking) Channel to AUX Power Isolation Channel to Channel Isolation Output Value in Fault Mode Load Impedance Maximum Capacitive Load Allowed Load Type Maximum Inaccuracy Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Maximum Crosstalk Linearity Error (End to End)

Output Specifications

6 (6 isolated) 10V 16 bit 16 Bit Resolution 10V = 305V -32768 to +32767 counts Voltage (10mA max current) 1800VDC applied for 1.8 second (100% tested) 900VDC applied for 1.8 second (100% tested) 0V 1000 .01F maximum Floating or grounded 0.1% of range .065% of range maximum voltage

Terminal block sold separately; terminal block cover included with module.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal (power-up, -down) External DC Power Required

.065% of range maximum 25 ppm/ C maximum f.s. calibration change ( .0025% of range / C) -96 dB, 1 LSB 16 LSB maximum (0.025% of full scale) Monotonic with no missing codes 10 LSB after 10 min. warm-up (typical) .01% of full scale .100 s max, 40 s min (full scale change) 1.05ms Outputs current limited to 15mA typical 15VDC Peak Output Voltage 0V 24 VDC (-20% / + 25%), 287mA

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800 VDC applied for 1.8 seconds (100% tested) >10M @ 500 VDC 5.8 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 108.8g (3.82 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.
Volume 13

e7-110

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-06DAS-2 (contd)
INTERNAL MODULE CIRCUITRY
CH1 DAC ISOLATED ANALOG OUTPUT CH2 DAC ISOLATED ANALOG OUTPUT CH3 DAC ISOLATED ANALOG OUTPUT CH4 DAC ISOLATED ANALOG OUTPUT CH5 DAC ISOLATED ANALOG OUTPUT CH6 DAC ISOLATED ANALOG OUTPUT
Voltage Output Circuits

Company Information Systems Overview Programmable Controllers Field I/O Software


V- can be either isolated or grounded. V+ 0 - 10 VDC Load V-

Voltage sink/source V1+ V2+ V1V2Voltage sink/source

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls

Transducer Power Supply

Voltage sink/source V3+ V4+ V3V4Voltage sink/source

V+ 10 VDC Load V-

Transducer Power Supply

Voltage sink/source V5+ V6+ V5V6Voltage sink/source

V+ -10 - 0 VDC Load V-

Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

Transducer Power Supply

NOTES: Shield connected to signal source common.

24VDC+ 24VDC+

6 OUTPUT DC/DC CONVERTER ISOLATED ANALOG POWER

24 VDC User Supplied Power

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-111

Analog Output Modules


P3-16DA-1
Current Analog Output

<--->

The P3-16DA-1 Current Analog Output Module provides sixteen channels of 4-20mA sourcing outputs.
C

UL
R

US

Output Channels Module Signal Output Range Output Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output Value in Fault Mode Load Impedence (Minimum External Power Supply)

Output Specifications

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Maximum Inductive Load Allowed Load Type Maximum Inaccuracy

Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (end to end)

16 (non-isolated) 4-20mA 16-bit 4-20mA = .244A/count 1 LSB = 1 count 0 to 65535 counts Less than 4mA 0-570 (19.2 VDC) 0-690 (21.6 VDC) 0-810 (24.0 VDC) 0-930 (26.4 VDC) 0-1100 (30.0 VDC) Minimum Load 0 0-45C, 125 ambient 1 mH Grounded 0.1% of range (including temperature drift) 0.025% of range maximum

45-60C,

Terminal block sold separately; terminal block cover included with module.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal at Power-up and Power-down External DC Power Required

.025% of range maximum 25 ppm/ C maximum full scale calibration change ( .0025% of range / C) -96 dB, 1 LSB 16 LSB maximum (0.025% of full scale) monotonic with no missing codes 10 LSB after 10 min. warm-up (typical) 0.05% of full scale 0.3 ms max, 5 s min (full scale change) 0.6 ms Outputs open circuit protected Electronically current limited to 20mA or less 4mA 24 VDC (-20% / + 25%), 356mA

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 9.0 W Open Equipment UL508 and UL1604 (Certified for Canada and USA) CE (EN61131-2:2003) This equipment is suitable for use in Class I, Division 2/Zone 2, Groups A, B, C, and D or nonhazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Volume 13

e7-112

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-16DA-1 (contd)
FIELD WIRING
I 1+ I 2+ I 3+ I 4+ I 5+ I 6+ I 7+ I 8+
COM COM

Company Information Systems Overview Programmable Controllers Field I/O

INTERNAL MODULE CIRCUITRY


4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing CH1 DAC CH2 DAC CH3 DAC CH4 DAC CH5 DAC CH6 DAC CH7 DAC CH8 DAC
4 - 20mA Load I+ COM

Software C-more & other HMI Drives Soft Starters

Current Source Output Circuit

Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

I 9+ I10+ I11+ I12+ I13+ I14+ I15+ I16+


24VDC24VDC+ + -

4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing 4-20 mA current sourcing

CH9 DAC CH10 DAC CH11 DAC CH12 DAC CH13 DAC CH14 DAC CH15 DAC CH16 DAC
NOTE: Shield is connected to common at the source device.

ISOLATED ANALOG CIRCUIT POWER

24 VDC User Supplied Power ISOLATED ANALOG CIRCUIT COMMON

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-113

Analog Output Modules


P3-16DA-2
Voltage Analog Output

<--->

The P3-16DA-2 Voltage Analog Output Module provides sixteen channels of 10VDC outputs.
C

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (end to end)

Output Channels Module Signal Output Range Output Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output type (sourcing/sinking) Output Value in Fault Mode Output Impedance Load Impedance Maximum Capacitive Load Allowed Load Type Maximum Inaccuracy

Output Specifications

Terminal block sold separately; terminal block cover included with module.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection External DC Power Required

.025% of range maximum 25 ppm/ C maximum f.s. calibration change ( .0025% of range / C) -96 dB, 1 LSB 16 LSB maximum (0.025% of full scale) Monotonic with no missing codes 10 LSB after 10 min. warm-up (typical) 0.05% of full scale 0.3 ms max, 5 s min (full scale change) 0.6 ms Outputs current limited to 40mA typical Continuous overloads on multiple outputs can damage the module. 0.1F Transient Suppressor 24 VDC (-20% / + 25%), 252mA

16 10VDC 16-bit 10V = 305V/count 1 LSB = 1 count -32768 to +32767 Voltage (10mA max current) 0V 0.2 typical 1000 .01F maximum Grounded 0.1% of range (including temperature drift) 0.025% of range maximum

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 6.4 W Open Equipment UL508 and UL1604 (Certified for Canada and USA) CE (EN61131-2*) This equipment is suitable for use in Class I, Division 2/Zone 2, Groups A, B, C, and D or nonhazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

WARNING: Explosion hazard Substitution of components may impair suitability for Class I, Division 2.

Volume 13

e7-114

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Output Modules


P3-16DA-2 (contd)

Company Information Systems Overview Programmable Controllers Field I/O Software

FIELD WIRING
V1+ V2+ V3+ V4+ V5+ V6+ V7+ V8+ COM COM V9+ V10+ V11+ V12+ V13+ V14+ V15+ V16+ 24VDC+ 24VDC+

INTERNAL MODULE CIRCUITRY


voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source CH1 DAC CH2 DAC CH3 DAC CH4 DAC CH5 DAC CH6 DAC CH7 DAC CH8 DAC

Voltage Output Circuits


V+ 0 - 10 VDC Load COM

C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos
V+

AC or DC Power Supply

voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source voltage sink/source

10 VDC Load CH9 DAC CH10 DAC CH11 DAC CH12 DAC CH13 DAC CH14 DAC CH15 DAC CH16 DAC -10 - 0 VDC Load Load Power Supply

COM

Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index

V+ COM

ISOLATED ANALOG CIRCUIT POWER

24 VDC User Supplied Power ISOLATED ANALOG CIRCUIT COMMON

Load Power Supply

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-115

Analog Input/Output Modules


P3-8AD4DA-1
Current Analog Input/Output

<--->

The P3-8AD4DA-1 Current Analog Input/ Output Module provides eight channels of current sinking 0-20mA inputs and four channels of current sourcing 4-20mA outputs.
C

Input channels Module Signal Input Range Signal Resolution Input Resolution & Update Rate See Note 1 Data Range Input Type Maximum Continuous Overload Input Impedance Hardware Filter Characteristics All Channel Update Rate See Note 2 All Channel Update Rate Open Circuit Detection Time Conversion Method Accuracy vs. Temperature Maximum Inaccuracy Linearity Error (end to end)

Input Specifications

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Terminal block sold separately; terminal block cover included with module.

Note 1: The Input Resolution of Fine returns 16 bit resolution. Medium and Coarse are 14 and 12 bit respectively. The 12 and 14 bit input values are scaled to 0-65535. Note 2: Valid when all channels are set for the same Input Resolution.

Input Stability and Repeatability Full Scale Calibration Error (not including offset) Offset Calibration Error Maximum Crosstalk Recommended Fuse (external) External DC Power Required

8 (1 common) 0 - 20mA 12-16 bit, depending on input resolution Fine: 7.1ms, 0.305A, 16 bit Medium: 1.78ms, 1.22A, 14 bit Coarse: 444s, 4.88A, 12 bit 0-65535 counts Single Ended (one common) 31mA 250 0.1% W Low pass 1st order, -3dB @ 48Hz Fine: 56.8ms Medium: 14.24ms Coarse: 3.55ms 56.8ms Zero reading within 1s Successive approximation 15PPM / C maximum 0.1% of range 0.015% of range maximum Monotonic with no missing codes 0.015% of range (after 10 min. warm up) 0.05% of range maximum

.0.05% of range maximum -96 dB 1 - 0.015% of full scale maximum Edison S500-32-R, 0.032A fuse 24 VDC (-20% / + 25%), 183mA maximum

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Outputs per module Module signal output range Output Signal resolution Resolution Value of LSB (least significant bit) Data Range Output Type Output Value in Fault Mode Load Impedance (Minimum Ext. Power Supply)

Output Specifications

4 (1 common) 4-20mA 16-bit 0.244A/count 1 LSB = 1 count 0 - 65535 counts Current sourcing, 20mA max 4mA 0-480 (19.2 VDC) 0-600 0-715 0-840 (21.6 VDC) (24.0 VDC) (26.4 VDC)

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Maximum Inductive Load Allowed Load Type Maximum Inaccuracy Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Maximum Crosstalk Linearity Error (end to end)

0-1010 (30.0 VDC) 1 mH Grounded 0.1% of range 0.065% of full scale

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal (power-up, -down)

0.065% of full scale 15 ppm/ C maximum full scale calibration change ( 0.025% of range / C) -96 dB 0.015% of range maximum Monotonic with no missing codes .015% after 10 min. warm-up typical .01% of Full Scale at 50/60 Hz Rising Time 200s Falling Time 135s (full scale change) 3.55 ms Outputs open circuit protected Electronically current limited to 20mA or less 4mA

Volume 13

e7-116

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input/Output Modules


P3-8AD4DA-1 (contd)
0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 3.8 W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 106.9g (3.76 oz)

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors
An Edison S500-32-R 0.032A fast-acting fuse is recommended for all current loops.

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

WARNING: Explosion hazard Substitution of components may


impair suitability for Class I, Division 2.
INTERNAL MODULE CIRCUITRY
I1+ I2+ I3+
250 250 250 250 250 250 250 250

Current Input Circuits

fuse

Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers

2-Wire 4-20 mA Transmitter


CH1 ADC CH2 ADC CH3 ADC CH4 ADC CH5 ADC CH6 ADC CH7 ADC CH8 ADC

.032A

+24VDC User Supplied Power


fuse

2-Wire Transmitter
+ 3-Wire Current Transmitter +

Input Channels

I4+ I5+ I6+ I7+ I8+ COM COM COM COM

.032A COM + +24VDC User Supplied Power


fuse

Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix

3-Wire Transmitter
+ User Supplied Transmitter Power

Output Channels

I1+ I2+ I3+ I4+ COM COM 24VDC+ 24VDC+

4-Wire 4-20 mA Transmitter


CH1 DAC CH2 DAC CH3 DAC CH4 DAC

.032A

AC or DC

4-Wire Transmitter
Note: Do not connect both ends of shield.

Current Output Circuits


ISOLATED ANALOG CIRCUIT POWER

24 VDC User Supplied Power

ISOLATED ANALOG CIRCUIT COMMON

4 - 20mA Load

Product Index Part # Index

Note: This module includes input and output channels. Before connecting field wiring, verify that you are connecting to the appropriate terminals.

Note: Shield is connected to common at the source device.

Volume 13

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

Programmable Controllers

e7-117

Analog Input/Output Modules


P3-8AD4DA-2
The P3-8AD4DA-2 Voltage Analog Input/ Output Module provides eight channels of 0-5 VDC and 0-10 VDC inputs and four channels of 0-5 VDC and 0-10 VDC outputs.
C

Voltage Analog Input/Output

<--->

Input channels Input ranges Signal resolution 0-5V Input Resolution & Update Rate See Note 1

UL
R

US

Patent-pending LCD gives access to field signal values, as well as module and signal faults.

Terminal block sold separately; terminal block cover included with module.

Note 1: The Input Resolution of Fine returns 16 bit resolution. Medium and Coarse are 14 and 12 bit respectively. The 12 and 14 bit input values are scaled to 0-65535. Note 2: Valid when all channels are set for the same Input Resolution.

8 inputs (1 common) 0 - 5V, 0 - 10V 12-16 bit, depending on input resolution Fine: 7.1ms, 76V, 16 bit Medium: 1.78ms, 305V, 14 bit Coarse: 444s, 1.22mV, 12 bit 0-10V Input Resolution & Update Rate Fine: 7.1ms, 152V, 16 bit See Note 1 Medium: 1.78ms, 610V, 14 bit Coarse: 444s, 2.44mV, 12 bit Data Range 0 - 65535 counts Maximum continuous overload 100V, voltage input Input impedance 1M ( 10%) voltage input Hardware Filter Characteristics Low pass 1st order, -3dB @ 80Hz All Channel Update Rate Fine: 56.8ms See Note 2 Medium: 14.24ms Coarse: 3.55ms Conversion Method Successive Approximation Accuracy vs. Temperature 15PPM / C Maximum Maximum Inaccuracy 0.1% of range Linearity Error (end to end) 0.015% of range maximum Monotonic with no missing codes Input Stability and Repeatability 0.025% of range (after 10 min. warm up) Full Scale Calibr. Error (minus offset) .05% of range maximum Offset Calibration Error .05% of range maximum Max Crosstalk -96dB External DC Power Required 24 VDC (-20% / + 25%), 90mA maximum

Input Specifications

Removable Terminal Block Specifications


Description Wire Range

Screw Driver Width Screw Size Screw Torque

Part No. P3-RTB; 20 screw terminals 22-14 AWG (0.324 to 2.08 sq. mm) Solid / stranded conductor 3/64 in. (1.2 mm) insulation maximum "USE COPPER CONDUCTORS , 60C" or equivalent. 1/4 inch (6.5 mm) maximum M3 size Field terminals 7 - 9 in./lb (.0.882 - 1.02 Nm) Self-jacking screws 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Do not overtighten screws when installing terminal block.

Data Range Output Type Output Value in Fault Mode Load Impedance Maximum capacitive load Allowed Load Type Maximum Inaccuracy Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (end to end)

Output channels Output ranges Output Signal resolution Resolution Value of LSB (least significant bit)

Output Specifications

4 (1 common) 0 - 10V, 0 - 5V 16-bit 0 - 5V = 76V/count 0 - 10V = 152V/count 1 LSB = 1 count 0 - 65535 counts Voltage sourcing/sinking at 10mA max. 0V 1125 .01F maximum Grounded 0.1% of range 0.065% of range maximum

We recommend using prewired ZIPLink cables and connection modules. See Wiring Systems.

Terminal block cover included. If you wish to handwire your module, a removable terminal block is sold separately. Order part number P3-RTB.

Output Stability and Repeatability Output Ripple Output Settling Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal (power-up, -down)

0.065% of range maximum 25 ppm/ C maximum full scale calibration change ( 0.0025% of range / C) -96 dB 0.015% of full scale Monotonic with no missing codes 0.015% after 10 min. warm-up typical .01% of Full Scale at 50/60 Hz 0.5 ms max, 5 s min (full scale change) 5ms Outputs current limited to 15mA typical 15VDC peak output voltage 0V

Volume 13

e7-118

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog Input/Output Modules


P3-8AD4DA-2 (contd)
0 to 60C (32 to 140F), -20 to 70C (-4 to 158F) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second >10M @ 500 VDC 2.5W Open Equipment UL508 file E157382, Canada & USA UL1604 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Keying to Backplane Electronic Module Location Any I/O slot in any local, expansion, or remote base in a Productivity3000 System. Field Wiring Removable terminal block (not included). Use ZIPLink wiring system or optional terminal block. See Wiring I/O Modules. EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Terminal Type (not included) 20-position removable terminal block Weight 105g (3.73 oz)

Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors
V+ COM Transmitter Power Supply

General Specifications
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Agency Approvals

*Meets EMC and Safety requirements. See the Declaration of Conformity for details.

impair suitability for Class I, Division 2.

WARNING: Explosion hazard Substitution of components may

Voltage Input Circuits


INTERNAL MODULE CIRCUITRY
V1+ V2+ V3+
4-Wire Voltage Transmitter AC or DC

Temperature Sensors Pushbuttons/ Lights Process

CH1 ADC CH2 ADC CH3 ADC CH4 ADC CH5 ADC CH6 ADC CH7 ADC CH8 ADC

4-Wire Transmitter +
3-Wire Voltage Transmitter
V+ COM +

Input Channels

V4+ V5+ V6+ V7+ V8+ COM COM COM COM

Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics

+ 3-Wire Transmitter

24 VDC User Supplied Power

Voltage Output Circuits

Output Channels

V1+ V2+ V3+ V4+ COM COM 24VDC+

CH1 DAC CH2 DAC CH3 DAC CH4 DAC

0-5 VDC Load

V+ COM

24VDC+

24 VDC User Supplied Power

ISOLATED ANALOG CIRCUIT POWER

0-10 VDC Load

V+ COM

Appendix Product Index Part # Index

w w w. a u t o m a t i o n d i r e c t . c o m / PA C s

ISOLATED ANALOG CIRCUIT COMMON

Note: This module includes input and output channels. Before connecting field wiring, verify that you are connecting to the appropriate terminals.

Volume 13

Programmable Controllers

e7-119

Anda mungkin juga menyukai