Update on Cardiac Anesthesia Glenn P. Gravlee, M.D. Aurora, Colorado

Like most medical subspecialties, cardiac anesthesia continues to move at a rapid pace. The three topics chosen for this years update affect day-to-day life in the cardiac ORs more often than in non-cardiac ones, but they nevertheless increasingly affect the clinical practice of anesthesiology outside the cardiac operating suites as well. These topics are ventricular assist devices, recombinant Factor VIIa, and cerebral oximetry. Ventricular Assist Devices. Over 500,000 new cases of congestive heart failure (CHF) present each year in the United States, and over 5 million patients are undergoing treatment for CHF. Only a subset of CHF patients can or should receive one of the limited number of cardiac transplants available each year (approximately 2,500), but continuing improvement in outcomes for ventricular assist devices (VAD) patients is increasing the appeal of that option. For the purpose of this lecture, principally destination-type left ventricular assist devices (LVADs) will be discussed. The term destination refers to using a VAD as the intended permanent treatment for advanced heart failure, as opposed to using it as a bridge to transplantation or recovery. Although most VAD therapy is still considered experimental by the FDA, a trial known as REMATCH (Randomized Evaluation of Mechanical Assistance in the Treatment of Congestive Heart Failure) showed survival benefit and improvement in the quality of life when VAD therapy was compared to medical management (Sun 2008). Although medical management of CHF has improved markedly over the past decade, the prospects for long-term survival appear less promising than do those for mechanical support. In 2006 Parides (2006) noted that the potential exists for implantation of 20,000-60,000 VADs per year as destination therapy for CHF, yet fewer than 500 implantations were then being performed annually in the US. He attributed this to a variety of causes including a cumbersome FDA approval process and refusal by some health insurance plans to reimburse for this procedure. The concurrent presence of several experimental VADs has impaired acquisition of sufficient numbers of patient implantations and long-term outcome measurements for any single device to attain standard-of-care status, but this limitation is diminishing as the Heartmate II nonpulsatile pump takes center stage. Since 2006 the annual number of LVAD implants has risen to a total approximating 1,000 in 2009, but this still falls far short of the projected need (INTERMACS). Most LVADs provide assistance by taking inflow from the apex of the left ventricle and delivering outflow into the ascending aorta. The greatest experience accumulated to date has been with the Thoratec Heartmate (Thoratec, Inc., Pleasanton, CA) series of pumps, which provide pulsatile assistance via a device implanted into a pocket in the anterior abdominal wall; the device contains inflow (mitral) and outflow (aortic) valves. Biocompatibility of the blood contact surfaces is sufficiently favorable that patients can usually be managed long-term with just aspirin antithrombosis prophylaxis. The device is a bit bulky and requires an external power source, but the external hardware required is equivalent to that of many pulmonary patients who require round-the-clock oxygen supplementation. Axial flow pumps (e.g., Heartmate II, Thoratec, Inc., Pleasanton, CA; Jarvik 2000 (Cardiowest), Syncardia, Tucson, AZ; DeBakey VAD, Micromed Cardiovascular, Inc. Houston, TX) provide sufficient flows with less bulk by using a continuous flow mechanism that requires no valves (Sun 2008). This nonpulsatile mechanism is efficient but complicates and sometimes precludes noninvasive assessment of blood pressure and SPO2. The Heartmate II appears to have become the dominant player among destination LVADs, and accumulating experience shows substantially better durability with fewer complications as compared to the pulsatile Heartmate devices that previously dominated destination LVAD implantations. In a prospective comparison among 200 destination LVAD patients, Slaughter et al. recently reported a 58% two-year stroke free survival rate using the nonpulsatile Heartmate II, as compared to 24% for the most current version of the pulsatile Heartmate pump (Heartmate XVE) (Slaughter 2009). Heartmate II can generate flows up to 10 L/min, but it does require traditional anticoagulation rather than just aspirin, i.e., typically heparin or a direct thrombin inhibitor for short-term use and warfarin for longer-term use. Clinical trials will soon begin for an impeller-driven pump (MVAD for Miniature VAD, HeartWare, Inc., Miramar, FL) that displaces only 15 mL of blood and can be implanted in the pericardium without an external pocket. This pump runs at very high RPMs, generates over 5 LPM flow in calves, and may not require anticoagulation (Slaughter 2009 B). This pump could potentially revolutionize destination VAD therapy.

110 Page 2 If a temporary RVAD is needed, the most commonly used pump is a nonpulsatile centrifugal unit called Centrimag (Levitronix LLC, Waltham, MA) (Bhama 2009). This pump can also be used as an LVAD or in series for both ventricles (BiVAD), typically as a bridge to transplantation. This pump generates up to 10 L/min flow, so it should be sufficient as an RVAD for almost any situation except pumping against very high PA pressures. Anesthetic considerations. The considerations that apply to patients with advanced cardiomyopathy mostly apply to VAD implantation as well. TEE is even more essential because one needs to diagnose and close any patent foramen ovale, diagnose and remove thromboses in the left atrium or ventricle, and diagnose and repair any aortic insufficiency (which can be devastating). In addition, TEE is used to assess for air evacuation, for appropriate VAD inflow and outflow characteristics, and for left and right ventricular filling and function. Often the initiation of LVAD flow unmasks RV dysfunction that may require aggressive pharmacologic management or even mandate the use of a right VAD as well. Often these patients experience a systemic vasoparesis after initiation of LVAD support, which requires the use of alpha-adrenergic agonists or vasopressin in order to sustain adequate systemic arterial pressures. Whereas pulsatile valved VADs are afterload insensitive (analogous to CPB with a roller pump), continuous flow VADs are afterload sensitive (analogous to CPB with a centrifugal pump), hence higher systemic vascular resistance levels can seriously compromise systemic blood flow even in the presence of normal systemic arterial pressures. Most of these patients will require mechanical ventilation at least overnight, so there is little advantage to fast-track anesthesia. Complex coagulation disturbances, anticoagulation regimens, and re-exploration for bleeding are fairly common. Over 50% of destination VAD patients experience abdominal complications (Bhama 2010), and just over a third of those patients will require abdominal surgery, so the potential to see a VAD patient in a noncardiac operating room is substantial. Patients with nonpulsatile VADs appear to be more susceptible to upper GI bleeding than patients with pulsatile VADs (Crow 2009). When patients with indwelling nonpulsatile VADs present for noncardiac or cardiac surgery, blood pressure and SPO2 monitoring prove challenging when arterial blood flow predominantly passes through the VAD, as no arterial pulse is then present. Noninvasive BP measurements will be ineffective, and arterial catheter placement is complicated by the absence of a palpable pulse. In this scenario, ultrasound guidance facilitates placement of an arterial catheter. Doppler flow detectors can also be used with a traditional BP cuff and an anaeroid manometer to approximate mean arterial pressure. If there is any native pulsatility whatsoever (representing arterial blood flow through the aortic valve rather than the LVAD), pulse oximetry has a chance for success. When pulsatility is absent, a pulse oximeter may not detect a signal, and one might then consider transcutaneous cerebral oximetry for continuous monitoring of oxygenation. Both cardiac and noncardiac anesthesiologists may benefit from some familiarity with the Tandem Heart percutaneous LVAD (pVAD), because this device is sometimes used to rescue patients with cardiogenic shock from a myocardial infarction or high-risk percutaneous coronary artery procedures that have gone awry. The potential involvement of anesthesiologists with these patients ranges from monitoring and urgent intubation up to general anesthesia for a deteriorating patient who needs completion of a stent procedure or a rescue sternotomy for CABG and/or cardiac tamponade. This centrifugal pump obtains venous return from the left atrium via the femoral vein and a trans-atrial septal puncture, and provides arterial return via the femoral artery to the approximate level of the aortic bifurcation (Kar 2006). The pump can deliver flows as high as 4 L/min, but it will fail if the lungs insufficiently oxygenate the blood or if the right ventricle is also failing. Tandem pVADs typically require heparin anticoagulation. We are seeing increasing use of this device at our referring hospitals as a means for stabilization prior to transportation to our established VAD center. The Tandem device will not suffice as a long-term VAD, and it may provide insufficient flow for patients with large body surface areas or very high systemic oxygen demands (e.g., septic patients). Factor VIIa Off-label use of recombinant Factor VIIa (rVIIa) has become a popular rescue therapy for coagulopathy after cardiopulmonary bypass. The paucity of prospective, randomized clinical trials continues to obfuscate attempts to establish consensus guidelines for its use. Scattered reports of thrombotic complications, including some fatalities, serve as a sobering reminder that use of this drug should not be taken lightly, as does its astounding expense (Syburra 2010, Mazer 2007, Mahmoud 2008). Since most clinicians agree that the use of this drug can have a profound and even life-saving effect, it is not surprising that clinical reports, reviews, and observational

110 Page 3 studies continue to proliferate. An Ovid database search of the topic recombinant VIIa and cardiac surgery over the past 5 years yielded almost 100 hits. This section will briefly review recent additions to the literature on this topic. Efficacy: Recent uncontrolled studies confirm the apparent efficacy of rVIIa in reducing the magnitude of bleeding and/or transfusion in adults or children who have a refractory coagulopathy after CPB (Millan 2009, Karsies 2010, Masud 2009, Tatoulis 2009, Guzetta 2009, Kylasam 2009, Gelsomino 2008, Karkouti 2008). A 2009 metaanalysis including 5 clinical trials and 298 patients showed trends toward a reduced incidence of surgical reexploration as well as toward an increased incidence of strokes when rVIIa was used as rescue therapy (Zangrillo 2009). A systematic review of 29 reports containing 169 pediatric cardiac surgical patients supported improved hemostasis while also finding a troubling 20% incidence of thrombotic complications in ECMO patients (Warren 2009). A rare prospective, randomized, dose-escalating clinical trial in 182 bleeding cardiac surgical patients showed reduced reoperation and transfusion in the rVIIa groups and a nonsignificant (but nearly double) difference in the incidence of severe adverse events in patients receiving rVIIa (Gill 2009). The study lacked sufficient power to draw conclusions about the latter findings, since the highest incidence of severe adverse events in any group was 14%. Some analyses suggest a positive relationship between dose and thrombotic events (Mazer 2007, Johnson 2007). A recent review by Hardy et al. casts doubt upon rVIIas hemostatic efficacy when assessing only randomized control trials involving off-label use (with or without cardiac surgery) in hemorrhaging patients (Hardy 2009). Dosing: Willis et al. retrospectively reviewed a multi-institutional registry to assess the relationship between rVIIa dosing and outcomes in 804 cardiac surgical patients who received this drug (Willis 2010). Although most clinicians selected a dose of 81-100 U/kg (N=368), a dose of < 40 U/kg (N=42) performed just as well in terms of bleeding, thromboembolic, and mortality outcomes. This makes sense, because in medical patients, doses around 30 u/kg have fairly reliably restored INR with coumadin overdose or profound hepatic dysfunction, whereas doses >80 u/kg have mainly been required only in situations such as refractory hemophilia. Johnson et al. suggest that the optimal trade-off among efficacy, thrombosis risk, and cost may occur at an initial dose level of 45 U/kg in bleeding cardiac surgical patients (Johnson 2007). Perhaps only in situations of very rapid bleeding (hence faster turnover of blood volumes) would a higher initial dose be appropriate. Summary: Factor VIIa use in cardiac surgery continues to evolve. Results from a limited number of randomized trials are much less encouraging than those from numerous observational studies. More randomized trials are needed. At present, no firm best practice guideline can be offered, but it seems reasonable to use rVIIa if post-CPB coagulopathy remains substantial after 1-2 rounds of traditional clotting factors have been given, especially if rapid bedside coagulation testing then shows laboratory deficits likely to respond to rVIIa (e.g., prolonged PT/INR, aPTT, or r or k time on TEG). If rVIIa is used, an initial dose of 30-50 U/kg seems appropriate for most cardiac surgery patients. Cerebral Oximetry The need for a CNS monitoring technique that could reduce the incidence of perioperative stroke and neurocognitive dysfunction has been ongoing for decades. The incidence of stroke after cardiac surgery ranges from 1% to over 10%, and the incidence is influenced by such factors as increasing patient age, open vs closed cardiac surgery, preexisting aortic atherosclerosis, pre-existing cerebrovascular disease, and duration of cardiopulmonary bypass (Tan 2008). Both strokes and neurocognitive deficits after cardiac surgery substantially correlate with embolic phenomena that occur as a result of events surrounding CPB, but global hypoperfusion can also contribute to these deficits (Tan 2008). If a cerebral monitor could serve as an early warning device and then alter patient management in a way that would reduce perioperative neurologic and neurocognitive deficits, this would constitute a major advance, especially in view of an increasingly elderly cardiac surgical patient population. Transcutaneous cerebral oximetry has been advanced as a means to that end. A number of case reports have cited regional cerebral oxygen saturation (rSO2) measurements as an early warning system for catastrophic events that were thought to have been avoided as a result of the measurements obtained (Tan 2008). Transcutaneous near-infrared oximetry (NIRS) utilizes many of the same two-wavelength near-infrared spectroscopic principles as pulse oximetry, but differs by being based on nonpulsatile reflectance spectroscopy that

110 Page 4 uses a mathematical algorithm to approximate a 75% venous/25% arterial oximetry mixture. Therefore, the most commonly used device (INVOS, Somanetics Corp., Troy, MI) approximates jugular bulb oxygen saturation by performing transcutaneous measurements from the forehead overlying the frontotemporal cerebral cortex. A similar device called NIRO is manufactured in Japan (Hamamatsu Photonics) and lacks FDA approval to my knowledge. Relatively recently a transcutaneous cerebral oximeter called FORE-SIGHT (CAS Medical Systems, Inc., Branford, CT) has received FDA approval. This device purports to non-invasively measure and report brain tissue oxygen saturation every two seconds via near-infrared sensors placed on the forehead. Whereas interpatient variation in the baseline values obtained by the INVOS causes its manufacturer to strongly recommend a baseline determination prior to anesthesia and surgery, the FORE-SIGHT manufacturer believes that its determination of absolute brain oxygen saturation reduces or eliminates this need. Both devices provide bilateral frontotemporal information. In a preliminary study, intraoperative FORE-SIGHT mean values in 32 CABG patients varied from 60% (CPB) to 72% (pre-CPB) (MacLeod 2006). Subsequent comments will be limited to the INVOS, the device on which most clinical reports about cerebral oximetry have been based. INVOS rSO2 readings may be adversely affected by the overlying skull and bone, by abnormal hemoglobins (i.e., methemoglobin and carboxyhemoglobin), by dyes such as methylene blue, and by high bilirubin levels (Tan 2008). At times unexplained asymmetry may occur in healthy patients (Tan 2008). As noted above, interpatient variability has confounded attempts to define a normal range, and a 20% decrease from baseline values has been defined as a likely threshold for concern and intervention. Recommended interventions have included increasing CPB blood flows, increasing blood pressure, increasing hemoglobin, adjusting cannula positions, deepening anesthesia, increasing PaO2, initiating pulsatile perfusion, and increasing PaCO2 (Tan 2008). Two observational or retrospective studies suggested that optimization of rSO2 during cardiac surgery reduced neuropsychologic deficits or strokes (Yao 2004, Goldman 2004). Hong et al. prospectively correlated rSO2 declines with postoperative cognitive dysfunction in 100 patients undergoing valve surgery (Hong 2008). They found no correlation between rSO2 and cognitive dysfunction, but patients with greater cerebral desaturation did require longer hospital stays. Murkin et al. performed a prospective, randomized study in 200 patients in which the control group had blinded rSO2 measurements and no interventions. Control patients experienced longer periods of rSO2 desaturation, longer ICU stays, and greater overall major organ morbidity and mortality (Murkin 2007). The outcomes of mortality, stroke, renal failure requiring dialysis, prolonged ventilation, deep sternal infection, and re-operation were combined to reach statistical significance. The Murkin study was elegantly performed, but the lumping of outcomes does raise some concern. One wonders if similar improvements might have been achieved by simply setting aggressive systemic perfusion targets involving flows, arterial pressures, and mixed venous O2 saturation levels. Operations involving particular risk to global or regional cerebral perfusion (e.g., circulatory arrest, selective antegrade cerebral perfusion, retrograde cerebral perfusion) have been advanced as particularly appealing situations for the use of cerebral oximetry. Accordingly, Kussman et al. recently monitored rSO2 during CPB in 104 infants undergoing biventricular repairs requiring CPB, 39 of whom required deep hypothermic circulatory arrest (Kussman 2009). They found no correlation between rSO2 and early postoperative outcomes after adjustment for diagnosis. There was some variation in rSO2 with anatomic diagnosis, however. Some authors advocate multimodal CNS monitoring during cardiac surgery, combining usual global perfusion markers with various combinations of cerebral oximetry, transcutaneous Doppler, and multilead EEG monitoring. These approaches have not as yet been subjected to prospective placebo-controlled or comparison trials. (Yeh 2003, Lozano 2004). The pros and cons of cerebral oximetry have been reviewed relatively recently, and few or no prospective investigations appear to be ongoing. Nevertheless, the various manufacturers of cerebral oximeters have mounted a marketing blitz targeted at cardiothoracic surgeons and anesthesiologists. The manufacturers appear to astutely recognize that many cardiac surgeons can be convinced to advocate for any monitor that might improve patient outcomes, even if the outcome data supporting any single cerebral monitor or combination of cerebral monitors during cardiac surgery remains rather sparse. The expense of NIRS is not prohibitive, but neither is it negligible at $150-250 per case depending upon the device and upon the particulars of a contract.

110 Page 5 Summary: Although there is justifiable enthusiasm for a monitoring technique that can diagnose cerebral insults in time to permit meaningful preventive intervention during cardiac surgery, the outcomes-based evidence supporting cerebral oximetry or multimodal cerebral monitoring used for that purpose remains thin. Anecdotal reports and some clinical studies are encouraging, but more prospective studies are needed before routine or even selective use can be strongly recommended. References Ventricular Assist Devices Parides MK. Ann Thorac Surg 2006;82:1140-6 Sun BC. Devices of cardiac replacement, in Hensley et al., editors. A Practice of Cardiac Anesthesia, 2008, 4th Edition, Philadelphia, Lippincott Williams and Wilkins INTERMACS registry, statistical report, www.INTERMACS.com Slaughter MS, NEJM 2009;361:2241-51 Slaughter MS, Texas Heart Inst J 2009;36:12-16 (B) Bhama JK, J Heart Lung Tplt 2009; Bhama JK, Ann Thorac Surg 2010;89:522-9 Crow S, J Thorac Cardiovasc Surg 2009;137:208-15 Kar B, Texas Heart Inst J 2006;33:111-5 Factor VIIa Syburra T, Ann Thorac Surg 2010;89:1643-5 Mazer CD, Sem Cardiothorac Vasc Anes 2007;11:261-4 Mahmoud A, Texas Heart Inst J 2008;34:485-8 Millan C, Revista Espaniola de Anestesiologia y Reanimacion 2009;56:485-92 Karsies TJ, Ann Thorac Surg 2010;89:570-6 Masud F, J Cardiothorac Vasc Anes 2009;23:28-33 Tatoulis J, Interactive Cardiovasc Thorac Surg 2009;9:459-62 Guzetta NA, Paediatric Anaesthesia 2009;19:364-70 Kylasam S, J Intens Care Med 2009;24:116-21 Gelsomino S, Eur J Cardiothorac Surg 33: 64-71 Karkouti K, Circulation 2008;118:331-8 Zangrillo A, J Cardiothorac Vasc Anes 2009;23:34-40 Warren OJ, Ped Crit Care Med 2009; 10:604-5 Gill R, Circulation 2009;120:21-7 Johnson S, Am J Health-System Pharm 2007;64:1808-12 Hardy J-F, Curr Opin Anaesthesiol 2009;22:95-9 Willis C, Vox Sanguinis 2010;98:531-7 Cerebral Oximetry Tan ST, Hong Kong Med J 2008;14:220-5 MacLeod D, Anesth Analg 2006;102:S162 Yao FS, J Cardiothorac Vasc Anes 2004;18:552-8 Goldman S, Heart Surg Forum 2004;7:E376-8 Hong SW, Eur J Cardio-thor Surg 2008;33:560-5 Murkin JM, Anesth Analg 2007;104:51-8 Kussman BD, Anesth Analg 2009;108:1122-31 Yeh T, J Thorac Cardiovasc Surg 2003;126:589-91 Lozano S, J Cardiothorac Vasc Anes 2004;18:645-56