Anda di halaman 1dari 9

Overseas Bechtel, Inc.

PACKAGE 61: AIRPORT OPERATIONS FACILITIES


Contract No.: 25045-000-FC1-C000-00061 Document No.: 25045-C1000-61-3PS-A-02361 REV. 0

Architectural Specifications Section 02361 Termite Control


ISSUED FOR CONSTRUCTION (IFC) SUBMITTTAL
DECEMBER 2009

REV.NO.
0

DATE
DECEMBER09

DESCRIPTION
ISSUEDFORCONSTRUCTION

PREPARED
MICHAELBAILEY

CHECKED
DEANESTREMADURA

APPROVED
JOHNWINDRUM

Section 02361 Termite Control

Rev. 0

SECTION 02361 TERMITE CONTROL PART 1 GENERAL


1.1 A. RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. SUMMARY A. This Section includes the following: 1. 2. 3. 4. B. 1. 2. Soil treatment with termiticide. Wood treatment with borate Bait-station system. Metal mesh barrier system. Division 1 Section "LEED Requirements" for additional LEED requirements. Division 6 Section "Rough Carpentry" for wood preservative treatment by pressure process.

1.2

Related Sections include the following:

1.3 A. B. C. D. 1.4 A.

ACRONYMS AND ABBREVIATIONS EPA ASHRAE LEED HCFC Environmental Protection Agency American Society of Heating, Refrigerating, and Air-Conditioning Engineers Leadership in Energy and Environmental Design Hydrochlorofluorocarbons

UNIT PRICES Basis of Bids: Unit price for each termite bait station(s) provided. 1. See Division 1 Section "Unit Prices" for list of unit prices.

1.5 A.

PERFORMANCE REQUIREMENTS Comply with the following: International Building Code (IBC 2003); Qatar Construction Standards; Applicable Qatar local codes and standards and all other applicable specifications, codes and standards described in the NDIA Design Basis. Service Life of Soil Treatment: Soil treatment by use of a termiticide that is effective for not less than 10 years against infestation of subterranean termites. SUBMITTALS A. Product Data: For termiticide, borate, bait-station system, and metal mesh barrier system. 1. Include the EPA-Registered Label and Material Safety Data Sheet
Page 1 of 8 25045-C1000-61-3PS-A-02361 New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

B.

1.6

Section 02361 Termite Control

Rev. 0

(MSDS) for termiticide and borate products. B. C. D. Product Certificates: For termite control products, signed by product manufacturer. Qualification Data: For Installer of termite control products. Equipment Certification: Certificates of calibration tests conducted on the equipment used in the termiticide application. Soil Treatment Application Report: After application of termiticide is completed, submit report for Engineers record information, including the following: 1. 2. 3. 4. 5. 6. 7. F. Date and time of application. Moisture content of soil before application. Brand name and manufacturer of termiticide. Quantity of undiluted termiticide used. Dilutions, methods, volumes, and rates of application used. Areas of application. Water source for application.

E.

Wood Treatment Application Report: After application of borate is completed, submit report for Employer's record information, including the following: 1. 2. 3. 4. 5. Date and time of application. Brand name and manufacturer of borate. Quantity of undiluted borate used. Dilutions, methods, volumes, and rates of application used. Areas of application.

G.

Bait-Station System Application Report: After installation of bait-station system is completed, submit report for Employer's records information, including the following: 1. 2. 3. Location of areas and sites conducive to termite feeding and activity. Plan drawing showing number and locations of monitoring stations and bait stations. Dated report for each monitoring and inspection occurrence indicating level of termite activity, procedure, and treatment applied before time of Substantial Completion. Brand name and manufacturer of termiticide. Quantities of termite bait used. Schedule of inspections for one year from date of Substantial Completion.

4. 5. 6.

H.

Warranty: Special warranty specified in this Section.

Page 2 of 8 25045-C1000-61-3PS-A-02361

New Doha International Airport (Package No. 61) Airport Operations Facilities

December 2009 Issued For Construction

Section 02361 Termite Control

Rev. 0

1.7

QUALITY ASSURANCE A. Unless accepted otherwise by the Engineer, use manufacturers and installers that employ a Quality Management System complying with the program described in ISO 9001-2000, or similar system. B. Installer Qualifications: A specialist who is licensed according to regulations of authorities having jurisdiction to apply termite control treatment and products in jurisdiction where Project is located, and who employs workers trained and approved by bait-station system manufacturer to install manufacturer's products. Regulatory Requirements: Formulate and apply termiticides according to the EPARegistered Label. Source Limitations: Obtain termite control products from a single manufacturer for each product. Preinstallation Conference: Conduct conference at Project site to comply with requirements in Division 1 Section "Project Management and Coordination" to schedule application of termiticide products. Copies of daily records signed by an officer of the Contractor. SUSTAINABLE DEVELOPMENT Refer to Division 1 specifications for sustainable development and LEEDS requirements. CORROSION PROTECTION A. The climate at the project site is particularly corrosive due to its proximity to the ocean, the resulting saline atmosphere, and the high average temperatures. The intense solar radiation is also a cause of accelerated aging of materials, as is the significant accumulation of fine sand and dust due to the nature of local soils. The Contractor will make all provisions necessary to propose, for the prior approval of the Engineer, and then to install, non-corroding products and materials where appropriate including aluminum, stainless steel, other non-corroding metals, and plastics. In the case where no alternative to steel or other oxidizing metal is possible (or where the specifications specifically indicate the use of steel), the steel or other material must be effectively protected against corrosion (by galvanization and/or protective paint coatings, for example) with an anticorrosion guarantee of 10 years. In all other cases, the Contractor will be asked to modify if necessary the proposed product (even if a catalogue or manufactured item) and to replace the corroding-type materials by non- corroding materials. MAINTENANCE AND REPAIR Where possible the Contractor is to use suppliers of materials, products and equipment from companies having an office and maintenance service based in Qatar. WORK REASONABLY INFERRED Contractor shall execute the Work in accordance with the intent and meaning of the Drawings and Specification and shall supply all accessories and other items essential for the proper Performance and Completion of the Work and shall execute all Work, including the supply of necessary materials, which can be reasonably
Page 3 of 8 25045-C1000-61-3PS-A-02361 New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

C. D.

E.

F. 1.8 A.

1.9

1.10 A.

1.11 A.

Section 02361 Termite Control

Rev. 0

inferred, whether or not specifically shown or described in the Drawings and Specification. 1.12 A. PROJECT CONDITIONS Environmental Limitations:To ensure penetration, do not treat soil that is water saturated. Do not treat soil while precipitation is occurring. Comply with requirements of the EPA-Registered Label and requirements of authorities having jurisdiction. COORDINATION Coordinate soil treatment application with excavating, filling, grading, and concreting operations. Treat soil under footings, grade beams, and groundsupported slabs before construction. Apply borate treatment after framing, sheathing, and exterior weather protection is completed but before electrical and mechanical systems are installed. Install bait-station monitoring system during construction to determine areas of termite activity. Install bait-station system after construction, including landscaping, is completed. WARRANTY Special Warranty: Manufacturer's standard form, signed by Applicator and Contractor certifying that termite control work, consisting of applied soil termiticide treatment, will prevent infestation of subterranean termites. If subterranean termite activity or damage is discovered during warranty period, re-treat soil and repair or replace damage caused by termite infestation. 1. 1.15 A. Warranty Period: 10 years from date of Final Acceptance.

1.13 A.

B. C. D. 1.14 A.

MAINTENANCE SERVICE Continuing Service: Beginning at Final Acceptance, provide 12 months' continuing service including monitoring, inspection, and re-treatment for occurrences of termite activity. Provide a standard continuing service agreement. State services, obligations, conditions, and terms for agreement period; and terms for future renewal options.

PART 2 PRODUCTS
2.1 A. MANUFACTURERS Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 1. Termiticides: a. b. c. d.
Page 4 of 8 25045-C1000-61-3PS-A-02361

Aventis Environmental Science USA LP; Termidor. Bayer Corporation; Premise 75. Dow AgroSciences LLC. FMC Corporation, Agricultural Products Group.
New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

Section 02361 Termite Control

Rev. 0

2.

Borates: a. b. c. Nisus Corp.; Bora-Care, Jecta. NovaGuard Technologies, Inc.; Armor-Guard, Shell-Guard. U.S. Borax Inc.; Tim-Bor. Dow AgroSciences LLC; Sentricon System. Ensystex, Inc.; Quarterra System. FMC Corporation, Agricultural Products Group; First Line Systems.

3.

Bait-Station Systems: a. b. c.

2.2 A.

SOIL TREATMENT Termiticide: Provide an EPA-registered termiticide complying with requirements of authorities having jurisdiction, in an aqueous solution formulated to prevent termite infestation. Provide quantity required for application at the label volume and rate for the maximum termiticide concentration allowed for each specific use, according to product's EPA-Registered Label. WOOD TREATMENT A. Borate: Provide an EPA-registered borate complying with requirements of authorities having jurisdiction, in an aqueous solution for spray application and a gel solution for pressure injection, formulated to prevent termite infestation in wood. Provide quantity required for application at the label volume and rate for the maximum diffusible borate concentration allowed for each specific use, according to product's EPA-Registered Label. BAIT-STATION SYSTEM A. Provide bait stations and monitoring stations based on the dimensions of building perimeter indicated on Drawings, according to manufacturer's EPARegistered Label for product, manufacturer's written instructions, and the following: 1. Not less than 1 station per 6.1 linear meters.

2.3

2.4

2.5 A. B.

METAL MESH BARRIER SYSTEM Product: Subject to compliance with requirements, provide "TERMI-MESH" by TERMIMESH, Inc. Stainless-Steel Mesh: 0.64 by 0.45mm mesh of 2.0mm diameter, stainless-steel wire, Type 316.

PART 3 EXECUTION
3.1 A. EXAMINATION Examine substrates, areas, and conditions, with Applicator present, for compliance with requirements for moisture content of soil, interfaces with earthwork, slab and foundation work, landscaping, and other conditions affecting performance of termite control. 1.
Page 5 of 8 25045-C1000-61-3PS-A-02361

Proceed with application only after unsatisfactory conditions have been


New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

Section 02361 Termite Control

Rev. 0

corrected. 3.2 A. PREPARATION General: Comply with the most stringent requirements of authorities having jurisdiction and with manufacturer's written instructions for preparation before beginning application of termite control treatment. Remove all extraneous sources of wood cellulose and other edible materials such as wood debris, tree stumps and roots, stakes, formwork, and construction waste wood from soil within and around foundations. Soil Treatment Preparation: Remove foreign matter and impermeable soil materials that could decrease treatment effectiveness on areas to be treated. Loosen, rake, and level soil to be treated except previously compacted areas under slabs and footings. Termiticides may be applied before placing compacted fill under slabs if recommended in writing by termiticide manufacturer. 1. Fit filling hose connected to water source at the site with a backflow preventer, complying with requirements of authorities having jurisdiction.

B.

3.3 A.

APPLICATION, GENERAL General: Comply with the most stringent requirements of authorities having jurisdiction and with manufacturer's EPA-Registered Label for products. APPLYING SOIL TREATMENT A. Application: Mix soil treatment termiticide solution to a uniform consistency. Provide quantity required for application at the label volume and rate for the maximum specified concentration of termiticide, according to manufacturer's EPARegistered Label, to the following so that a continuous horizontal and vertical termiticidal barrier or treated zone is established around and under building construction. Distribute treatment evenly. 1. Slabs-on-Grade and Basement Slabs: Under ground-supported slab construction, including footings, building slabs, and attached slabs as an overall treatment. Treat soil materials before concrete footings and slabs are placed. Foundations: Adjacent soil including soil along the entire inside perimeter of foundation walls, along both sides of interior partition walls, around plumbing pipes and electric conduit penetrating the slab, and around interior column footers, piers, and chimney bases; also along the entire outside perimeter, from grade to bottom of footing. Avoid soil washout around footings. Crawlspaces: Soil under and adjacent to foundations as previously indicated. Treat adjacent areas including around entrance platform and equipment bases. Apply overall treatment only where attached concrete platforms are on fill or ground. Masonry: Treat voids. Penetrations: At expansion joints, control joints, and areas where slabs will be penetrated.

3.4

2.

3.

4. 5. B.

Avoid disturbance of treated soil after application. Keep off treated areas until completely dry.
Page 6 of 8 25045-C1000-61-3PS-A-02361 New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

Section 02361 Termite Control

Rev. 0

C.

Protect termiticide solution, dispersed in treated soils and fills, from being diluted until ground-supported slabs are installed. Use waterproof barrier according to EPARegistered Label instructions. Post warning signs in areas of application. Reapply soil treatment solution to areas disturbed by subsequent excavation, grading, landscaping, or other construction activities following application. APPLYING BORATE TREATMENT

D. E.

3.5 A.

Application: Mix wood treatment borate solution to a uniform consistency. Provide quantity required for application at the label volume and rate for the maximum specified concentration of borate, according to manufacturer's EPARegistered Label, so that wood framing, sheathing, siding, and structural members subject to infestation receive treatment. 1. 2. 3. Framing and Sheathing: Apply borate solution by spray to bare wood for complete coverage. Wood Members Thicker Than 100mm: Inject borate gel solution under pressure into holes of size and spacing required by manufacturer for treatment. Exterior Uncoated Wood Trim and Siding: Apply borate solution to bare wood siding. After 48 hours, apply a seal coat of paint as specified in Division 9 painting Sections.

3.6 A.

INSTALLING BAIT-STATION SYSTEMS Place bait stations and, if applicable, monitoring stations, according to the EPA- Registered Label for the product and manufacturer's written instructions, in areas that are conducive to termite feeding and activity, as follows: 1. 2. 3. 4. 5. 6. 7. 8. B. Conducive sites and locations indicated on Drawings. In mulch beds. Where wood directly contacts soil. Areas of high soil moisture. Near irrigation sprinkler heads. Each area where roof drainage system, including downspouts and scuppers, drains to soil. At plumbing penetrations through ground-supported slabs. Other sites and locations as determined by licensed Installer.

Inspect and service stations from time of their application until completion of time period established by continuing service agreement, according to the EPARegistered Label for product and manufacturer's written instructions for termite management system and bait products.

3.7 A.

INSTALLING METAL MESH BARRIER SYSTEM Metal Mesh Barrier: Place metal mesh barrier where indicated to provide a continuous barrier to entry of subterranean termites. 1.
Page 7 of 8 25045-C1000-61-3PS-A-02361

Fit mesh tightly around pipe or other penetrations, and terminate at slab and
New Doha International Airport (Package No. 61) Airport Operations Facilities December 2009 Issued For Construction

Section 02361 Termite Control

Rev. 0

foundation perimeters. 2. Install mesh under the perimeter of concrete slab edges and joints after vapor barrier and reinforcing steel are in place, and comply with manufacturer's written installation methods. END OF SECTION 02361

Page 8 of 8 25045-C1000-61-3PS-A-02361