Anda di halaman 1dari 174

DISEO SISMORRESISTENTE DEL CONCRETO REFORZADO

por

Prof. Richard E. Klingner
La Universidad de Texas en Austin






Junio 2011



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


1

CONTENIDO

1. PREMBULO SOBRE EL DISEO SSMICO ..................................................................... 4
1.1 Repaso de la Dinmica Estructural ....................................................................................... 4
1.2 Principios Bsicos del Diseo Sismo-Resistente .................................................................. 5
1.2.1 Estimar la Demanda ...................................................................................................... 5
1.2.2 Calcular la Respuesta .................................................................................................... 6
1.2.3 Disear la Estructura ..................................................................................................... 7
1.2.4 Meta Fundamental del Diseo Ssmico ....................................................................... 10
2. COMPORTAMIENTO Y DISEO DE VIGAS DE CONCRETO REFORZADO ........... 12
2.1 Concepto de Regiones Crticas ........................................................................................ 12
2.2 Caractersticas Mecnicas de Materiales ............................................................................. 17
2.2.1 Acero de Refuerzo ....................................................................................................... 17
2.2.2 Concreto No Confinado .............................................................................................. 18
2.3 Relaciones Momento-Curvatura para Secciones de Concreto Reforzado ........................... 19
2.4 Efecto de Confinamiento Lateral del Concreto ................................................................... 24
2.4.1 Introduccin al Concepto del Confinamiento Lateral ................................................. 24
2.4.2 Confinamiento por Estribos Cerrados o Espirales ...................................................... 26
2.4.3 Relacin Esfuerzo-Deformacin para el Concreto Confinado .................................... 27
2.5 Relaciones Momento-Curvatura para Vigas de Concreto Reforzado ................................. 31
2.5.1 Relaciones Tericas Momento-Curvatura ................................................................... 31
2.5.2 Clculo de Relaciones Momento-Curvatura mediante Programas a Computadora .... 32
2.6 Relaciones Tericas Momento-Rotacin ............................................................................ 36
2.6.1 Pandeo del Acero Longitudinal ................................................................................... 36
2.6.2 Efectos del Corte ......................................................................................................... 38
2.6.3 Efecto de Cargas Alternas ........................................................................................... 40
2.6.4 Efecto sobre la Resistencia Cortante ........................................................................... 41
2.7 Relacin Terica Carga-Desplazamiento para el Concreto Confinado ............................... 42
2.7.1 Enfoque Terico ...................................................................................................... 45
2.7.2 Enfoques Empricos .................................................................................................... 45
2.7.3 Efecto del Agrietamiento Diagonal sobre u
p
............................................................... 46
2.8 La Ductilidad como Medida de Absorcin y Disipacin de Energa .................................. 47
2.9 Principios Bsicos del Diseo de Regiones Crticas de Vigas de Concreto Reforzado ...... 49
2.10 El Diseo Instantneo de Vigas de Concreto Reforzado ................................................. 50
3. COMPORTAMIENTO Y DISEO DE COLUMNAS DE CONCRETO REFORZADO 52
3.1 Prlogo sobre Semejanzas y Diferencias entre Requisitos para Columnas y para Vigas ... 52
3.2 Diagrama de Interaccin Momento-Fuerza Axial para Columnas de Concreto Reforzado,
Seccin Inicial ................................................................................................................................. 53
3.3 Ductilidad de Curvatura en Funcin de Fuerza Axial ......................................................... 57
3.4 Diagrama de Interaccin Momento-Fuerza Axial para Columnas de Concreto Reforzado,
Seccin Confinada .......................................................................................................................... 59
3.5 Clculo de Diagramas de Interaccin Momento-Fuerza Axial mediante Programas a
Computadora ................................................................................................................................... 63
3.6 Concepto de Diagrama de Interaccin, Gobernado por Corte ............................................ 68
3.7 Clculo de Diagramas de Interaccin Momento-Fuerza Axial (incluyendo Efectos de
Corte) mediante Programas a Computadora ................................................................................... 76
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


2
3.8 Observaciones sobre el Comportamiento de Regiones Criticas de Columnas de Concreto
Reforzado ........................................................................................................................................ 80
3.8.1 Papel de V
s
................................................................................................................... 80
3.8.2 Efectos de Fuerza Axial .............................................................................................. 80
3.8.3 Efectos de Carga Cclica Alterna ................................................................................ 81
3.8.4 Resumen de Mecanismos de Resistencia de Columnas de Concreto Reforzado ........ 81
3.9 Principios Bsicos del Diseo de Regiones Crticas de Columnas de Concreto Reforzado 82
3.10 Columnas Potencialmente Peligrosas .................................................................................. 87
3.11 El Diseo Instantneo de Columnas de Concreto Reforzado .......................................... 88
4. COMPORTAMIENTO Y DISEO DE CONEXIONES DE CONCRETO REFORZADO
90
4.1 Introduccin a Conexiones de Concreto Reforzado ............................................................ 90
4.2 Diseo de Conexiones Interiores por el Enfoque del ACI 318-08 ...................................... 90
4.2.1 Clculo de Fuerzas que Actan sobre las Conexiones Interiores ................................ 91
4.2.2 Porqu No Tenemos que Chequear Anclaje en Conexiones Interiores ....................... 93
4.2.3 Significado de los Requisitos del ACI 318-08 para Confinamiento ........................... 94
4.2.4 Ejemplo del Diseo de una Conexin Interior por el ACI 318-08 .............................. 95
4.3 Diseo de Conexiones Exteriores por el Enfoque del ACI 318-08 ..................................... 98
4.3.1 Clculo de Fuerzas que Actan sobre las Conexiones Exteriores ............................... 99
4.3.2 Porqu S Tenemos que Chequear Anclaje en Conexiones Exteriores ..................... 100
4.3.3 Ejemplo del Diseo de una Conexin Exterior por el ACI 318-08 ........................... 101
4.4 Conexiones de Rodilla ...................................................................................................... 104
5. REPASO DE PRINCIPIOS DE DISEO PARA ENSAMBLAGES DCILES DE
CONCRETO REFORZADO ......................................................................................................... 106
5.1 Diseo de Vigas de Concreto Reforzado .......................................................................... 106
5.2 Diseo de Columnas de Concreto Reforzado ................................................................... 110
5.3 Diseo de Conexiones Viga-Columna de Concreto Reforzado ........................................ 116
6. COMPORTAMIENTO Y DISEO DE MUROS CORTANTES DE CONCRETO
REFORZADO ................................................................................................................................. 120
6.1 Introduccin a Muros Cortantes de Concreto Reforzado .................................................. 120
6.2 Resistencia a Flexin de Muros Cortantes ........................................................................ 121
6.3 Capacidad Cortante de Muros Cortantes ........................................................................... 124
6.3.1 Falla por Agrietamiento del Alma ............................................................................. 124
6.3.2 Falla por Agrietamiento Cortante-Flexin ................................................................ 128
6.3.3 Sntesis de Modos de Falla Cortante Gobernados por V
c
.......................................... 130
6.3.4 Corte Resistido por Refuerzo Transversal................................................................. 130
6.4 Diseo de Muros Cortantes para Cargas Monotnicas ..................................................... 132
6.4.1 Diseo de Muros Cortantes por Carga Axial y Momento ......................................... 132
6.4.2 Diseo de Muros Cortantes por Corte ....................................................................... 132
6.5 Diseo Instantneo para Muros Cortantes ..................................................................... 133
6.6 Ejemplo de Diseo de un Muro Cortante .......................................................................... 134
6.7 Diseo de Muros Cortantes para Cargas Cclicas Alternas ............................................... 137
6.8 Interaccin Muro-Prtico .................................................................................................. 139
6.9 Muros Acoplados .............................................................................................................. 141
6.9.1 Comportamiento de Muros Acoplados ..................................................................... 141
6.9.2 Detallado de Vigas Acopladoras ............................................................................... 142
7. COMPORTAMIENTO Y DISEO DE LOSAS DE CONCRETO REFORZADO ......... 144
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


3
7.1 Introduccin al Diseo de Losas ....................................................................................... 144
7.2 Antecedentes sobre el Mtodo de Franjas ......................................................................... 145
7.3 Aplicacin del Mtodo de Franjas .................................................................................... 146
7.4 Ejemplos de Diseo, Mtodo de Franjas ........................................................................... 149
7.4.1 Ejemplo de Diseo, Losa de Una Sola Direccin ..................................................... 149
7.4.2 Ejemplo de Diseo, Losa de Dos Direcciones .......................................................... 151
8. PROYECTO DEL DISEO SSMICO EN CONCRETO REFORZADO ....................... 153
8.1 Introduccin al Diseo Preliminar .................................................................................... 153
8.2 Introduccin al Edificio del Diseo Preliminar ................................................................. 153
8.3 Clculo Preliminar de Acciones de Diseo ....................................................................... 154
8.3.1 Clculo de Cargas de Gravedad ................................................................................ 154
8.3.2 Clculo del Coeficiente Ssmico de Diseo .............................................................. 154
8.3.3 Clculo de Acciones Ssmicas de Diseo.................................................................. 155
8.4 Diseo Preliminar de Losa y Vigas ................................................................................... 156
8.5 Diseo Preliminar de Columnas ........................................................................................ 158
8.6 Diseo Preliminar de Conexiones Viga-Columna ............................................................ 160
8.6.1 Diseo Preliminar de Una Conexin Viga-Columna Interior ................................... 160
8.6.2 Diseo Preliminar de Una Conexin Viga-Columna Exterior .................................. 162
8.7 Diseo Preliminar del Ncleo ........................................................................................... 165
8.7.1 Diseo Preliminar del Ncleo por Flexin ................................................................ 165
8.7.2 Diseo Preliminar del Ncleo por Corte ................................................................... 168
8.8 Diseo Preliminar de los Muros Perimetrales ................................................................... 168
8.8.1 Diseo Preliminar de los Muros Perimetrales por Flexin ....................................... 168
8.8.2 Diseo Preliminar de los Muros Perimetrales por Corte ........................................... 171
8.9 Observaciones sobre el Refinamiento del Diseo ............................................................. 171
9. REFERENCIAS ...................................................................................................................... 173

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


4



1. PREMBULO SOBRE EL DISEO SSMICO


1.1 Repaso de la Dinmica Estructural

Consideremos un sistema de un slo grado de libertad es decir, un sistema cuya configuracin
espacial se define mediante una sola variable:


La ecuacin de equilibrio se expresa como




donde e=\K/M, y c es un coeficiente de amortiguacin equivalente viscosa, cuyo valor se escoge
para que el sistema disipe energa en el rango elstico, semejante al sistema original.

La solucin normalmente se calcula numricamente, paso a paso. De inters particular son los
valores mximos de la respuesta ssmica, los cuales se pueden graficar en forma de un espectro,
cuyas ordenadas indican el valor de la respuesta en funcin del perodo del sistema. Por ejemplo, el
espectro para aceleraciones da los valores de aceleracin absoluta (es decir, ndices de las fuerzas
inerciales que actan sobre la estructura), en trminos de perodo:


M
K
) (t u
g

T, seg
S
a
) ( 2
2
t u M Mu u M u M
g
= + + e ce
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


5
Utilizando un espectro, se puede calcular la respuesta mxima de una estructura frente a
determinado sismo, sin mucho trabajo. Los espectros analticos, suavizados hacia la forma
que se muestra arriba, pueden usarse para calcular fuerzas de diseo como una parte del
proceso de diseo ssmico.
En los cdigos modernos, tales espectros elsticos de diseo se modifican por los efectos de la
ductilidad, por la sobre-resistencia de la estructura, y por los efectos de respuesta multi-
modal.


1.2 Principios Bsicos del Diseo Sismo-Resistente

El diseo sismo-resistente implica tres facetas inter-relacionadas:


o Estimar la demanda (fuerzas, derivas, deformaciones)

o Calcular la respuesta

o Disear la estructura (global y localmente)


Estas facetas del proceso estn relacionadas entre s: la demanda depende del sitio y de las
caractersticas de la estructura misma; la respuesta depende de la estructura y de la demanda; y el
diseo depende de la demanda. Para desenredar este nudo gordiano, tenemos que ver las facetas al
principio por separadas, y luego juntarlas.


1.2.1 Estimar la Demanda

La demanda depende principalmente de las caractersticas intrnsecas ssmicas del sitio. Los sismos
vienen de los movimientos de la corteza terrestre, que se compone de placas gigantescas, que se
mueven muy lentamente, en tiempo geolgico, impulsadas (se estima) por las corrientes de piedra
derretida que fluyen dentro del ncleo de nuestra tierra.

Donde estas placas se chocan, pueden producirse varios tipos de falla:

1) En las llamadas zonas de subduccin, una placa se obliga a hundirse por debajo de otra.
Un ejemplo clsico de este tipo de zona es el lado occidental de Amrica del Sur, donde la
placa Nazca se mete debajo de la placa Suramericana. Este proceso produce el
levantamiento de la cordillera de los Andes, y tambin la trinchera que va a lo largo de la
costa occidental de Sudamrica.

2) En las llamadas zonas de levantamiento, una placa choca directamente contra otra, dando
lugar a un levantamiento local de la corteza terrestre. Un ejemplo clsico de esto es la
cordillera Himalaya, al norte de la India.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


6
3) En las llamadas zonas de falla, dos placas se mueven perpendicularmente a la lnea de
falla es decir, una placa se mueve lateralmente referente a la otra. Un ejemplo clsico de
esto es la famosa falla de San Andrs, que va a lo largo de la costa occidental de los EEUU,
trazando una raya por el estado de California.


Sea cual sea el tipo de falla, los sismos se producen debido al lento movimiento relativo de un lado
de una falla, a la otra. Debido a la asperidad de la interface, los dos lados de una falla no pueden
moverse libremente, uno respecto al otro. Entonces, el esfuerzo cortante sigue incrementndose,
hasta llegar a la resistencia cortante en una zona crtica. Esta condicin provoca una falla repentina
de la piedra en este lugar, que se llama el foco (hipocentro) del sismo. El punto geomtrico en la
superficie de la tierra directamente arriba del foco se llama el epicentro.

El punto de rotura puede moverse a lo largo de la superficie de falla, durante la produccin del
sismo. A veces, la rotura puede llegar hasta la superficie de la tierra, donde se muestra en forma de
brechas, escalones, o cambios evidentes en lneas rectas (cercos, carreteras, lneas de rieles). Esta
falla repentina suelta energa elstica, que se propaga por la piedra circunvecina en forma de ondas
elsticas. Tales ondas pueden ser ondas de cuerpo, o de superficie. Los varios tipos de onda tienen
sus propios caractersticas y velocidades de propagacin. Desde el punto de vista del diseo
estructural, basta con decir que tanto el contenido de frecuencia del sismo, como su duracin, como
su tamao, dependen de las caractersticas del movimiento de rotura, la profundidad del sismo, la
distancia focal, las caractersticas de la piedra entre el foco y el sitio de inters, y las caractersticas
locales del suelo subyacente en el sitio de inters.

Para nosotros, el tamao y el contenido de frecuencia del sismo se reflejan en el espectro de
respuestas. Podemos tratar de conocer los intervalos de retorno y las caractersticas de tamao y
frecuencia de los diversos sismos crticos para diferentes zonas del pas, desarrollando as un mapa
de riesgo ssmico, y diferentes espectros suavizados de diseo.



1.2.2 Calcular la Respuesta

La respuesta estructural se calcula usando modelos y mtodos que sean consistentes al rango de
respuesta de la estructura.

Si se contempla una respuesta elstica, el modelo estructural debe conformarse a esta premisa. El
coeficiente de amortiguamiento debe ser consistente con el grado de agrietamiento esperado. Si la
deriva esperada admite la supervivencia de elementos arquitectnicos, se deben incluir en el modelo.
Si la supervivencia de los elementos arquitectnicos est en tela de juicio, es preferible hacer varias
corridas, con y sin tales elementos.

Si se contempla una respuesta inelstica, el modelo estructural debe conformarse a esta premisa. Si
la deriva esperada implica la destruccin de elementos arquitectnicos, es preferible tantear,
haciendo dos modelos (como casos lmites), uno con tales elementos, y el otro sin ellos.
Normalmente, la respuesta inelstica se calcula implcitamente, usando un modelo elstico de la
estructura, sometido a un espectro de respuestas de fuerzas que incluye una reduccin en los niveles
de fuerzas de diseo, debida a la combinacin del comportamiento inelstico de la estructura, la
sobre-resistencia de ella, y la redundancia (grado de hiperestaticidad). Esta reduccin se hace
mediante el factor R. Las derivas correspondientes se multiplican un factor C
d
. Siempre hay que
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


7
recordar que las derivas reales de la estructura son las multiplicadas por C
d
, porque el espectro de
diseo ya ha sido reducido debido a la respuesta inelstica.

Si el calculista se extiende a calcular explcitamente la respuesta inelstica, es imprescindible usar
varias historias de entrada, representando varios sismos crticos. En el rango inelstico, la respuesta
estructural es muy sensible a pequeos cambios en la entrada, y a veces tambin a cambios en los
valores de rigidez y resistencia.


1.2.3 Disear la Estructura

El diseo de la estructura se conduce a dos niveles: el nivel global, y el nivel de los detalles. A nivel
global, se trata de proveer una estructuracin que sea consistente con las metas de diseo.


Caso Elstico

Si la estructura debe comportarse elsticamente, lo ms importante es proporcionarle suficiente
material (muros) para que los esfuerzos sean lo suficientemente bajos. Tambin son aconsejables los
siguientes pasos:

o Evitar exceso de masa (trae fuerzas inerciales).

o Minimizar la excentricidad en planta entre el centro de masa y el centro de rigidez. Tal
excentricidad aumenta las fuerzas en los muros ms alejados del centro de rigidez. En la
figura de abajo, se muestran algunos ejemplos de configuraciones en planta que dan lugar a
excentricidades en planta:





Centro de Masa Centro de Rigidez
Centro de Rigidez
Centro de Masa
Centro de Masa
Centro de Rigidez
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


8
o Distribuir los muros simtricamente en planta, y ponerlos en los extremos de la planta, para
aumentar la rigidez torsional de la estructura, y reducir as los incrementos de fuerza
provocados por la respuesta torsional.

o Evitar cambios bruscos en la rigidez de los muros, a lo alto de la estructura. Puesto que en el
rango elstico, el reparto interno de las acciones en una estructura hiperesttica depende de
las rigideces relativas de los miembros, los cambios bruscos de rigidez causan grandes
disparidades en las acciones en los miembros adyacentes, lo cual contribuye fallas locales en
tales sitios. En la figura de abajo, se muestran algunos ejemplos de tales cambios bruscos
indeseables:




Caso Inelstico

Si la estructura debe comportarse inelsticamente, lo ms importante es concebir un mecanismo
plstico que sea estable, y capaz de resistir varios ciclos de carga alternante. Se debe procurar, en lo
posible, mecanismos en los cuales las rtulas plsticas (es decir, zonas crticas donde se concentran
la deformaciones inelsticas) se distribuyen por la estructura, y en los cuales las rtulas plsticas en
los elementos portantes (es decir, columnas y muros) solamente se forman en la base de la estructura,
despus de haberse formado muchas rtulas en los elementos no portantes. Ejemplos de mecanismos
favorables y desfavorables se muestran en la figura de abajo.


Piso Blando Muros Discontinuos
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


9



Adems de eso, las siguientes prcticas son aconsejables:

o Evitar exceso de masa (trae fuerzas inerciales).

o Minimizar la excentricidad en planta entre el centro de masa y el centro de rigidez. Tal
excentricidad aumenta la demanda de deformaciones inelsticas en los muros ms alejados
del centro de rigidez. Distribuir los muros simtricamente en planta, y ponerlos en los
extremos de la planta, para aumentar la rigidez torsional de la estructura, y reducir as los
incrementos de fuerza provocados por la respuesta torsional.

o Evitar cambios bruscos en la resistencia de los muros, a lo alto de la estructura. Puesto que
en el rango inelstico, el reparto interno de las acciones en una estructura hiperesttica
depende de las resistencias relativas de los miembros, los cambios bruscos de resistencia
causan grandes disparidades en las acciones en los miembros adyacentes, lo cual contribuye
fallas locales en tales sitios. En el croquis de abajo, se muestran algunos ejemplos de tales
cambios bruscos indeseables:

Al nivel local, se deben disear las zonas crticas de la estructura para que sean capaces de
desarrollar la deformacin no lineal que se les espere. Esto implica la configuracin de los
miembros para favorecer a modos de falla dctiles en lugar de frgiles, y el clculo y arreglo del
acero para complementar tal fin. Los pasos especficos para lograr esta meta incluyen la llamada
diseo por capacidad, a travs del cual el diseo de los elementos contra el corte (y en el caso de
los edificios de mampostera, los muros en particular) debe basarse no en el corte correspondiente a
las cargas laterales de diseo, sino en el corte correspondiente a la formacin de rtulas plsticas,
distribuidas por el muro segn se haya previsto por el calculista.

En especial, para los elementos verticales, el diseo por capacidad implica la importancia de evitar
situaciones en las cuales el largo libre de un muro o una columna es tan corta que el desarrollo de
rtulas plsticas en los extremos corresponde a un corte superior a cualquier posible resistencia
cortante del miembro. Un ejemplo de esto se muestra en la figura de abajo. A la izquierda, sin
relleno de mampostera, las columnas tienen un largo de 2.5 m, correspondiente al corte mximo que
se indica. A la derecha, el uso de un relleno a la altura parcial de las columnas (lo que es algo
frecuente en bodegas y escuelas), produce llamadas columnas cautivas, mucho ms cortas que las
Mecanismos Favorables
Mecanismos Desfavorables
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


10
originales, y posiblemente sujetas a cortes mucho ms grandes. Tales columnas casi siempre fallan
en forma brusca, como se indica por la formacin de grietas en forma de X en el largo libre de la
columna.




Unir las Tres Facetas del Diseo

En los casos de diseo estructural contra cargas de gravedad, o contra el viento, solemos poner
criterios nicos. Por ejemplo, normalmente podemos confiar en la habilidad de una estructura de
resistir bien las fuerzas de la gravedad, o los valores normativos correspondientes al viento. En tales
casos, los valores que exige la norma representan valores superiores caractersticos, que no deben de
excederse en mas del 5% de los casos.

A diferencia de este planteamiento, cuando nos toca disear una estructura contra sismos, no
podemos contar con tanta confiabilidad sobre la seriedad de la solicitacin. Por lo tanto, hoy en da
se est planteando un enfoque de distintos estados lmites, o niveles de desempeo. Por
ejemplo, al dueo, o al ingeniero, le tocara proponer la calidad de la respuesta de la estructura,
frente a sismos de distintos tamaos. Por ejemplo, algn dueo prospectivo, o el calculista mismo,
podra proponer que frente a un sismo ligero, con intervalo de retorno de unos 5 o 10 aos,
determinado edificio debe de mantenerse en funcionamiento, sin prdida apreciable de
funcionamiento. Del mismo edificio, se le podra esperar que se mantuviese sin daos apreciables a
los acabados, frente a un sismo con intervalo de recurrencia de tal vez 50 aos. Finalmente, sera de
esperarse que el edificio se mantuviese parado frente al mximo sismo creble, digamos con intervalo
de retorno de 500 aos, o ms aun.

Cada uno de los tres niveles de sismo, entonces, representa un juego de entrada, respuesta, y diseo,
con las tres facetas relacionadas entre s. En cada estado lmite, la estructura debe disearse
mediante un conjunto consistente de entrada, modelacin, y diseo.


1.2.4 Meta Fundamental del Diseo Ssmico

En cualquier tipo de estructura, se busca un enfoque coherente, en el cual las varias facetas del
trabajo que culminan en la construccin de un edificio, sean consistentes entre s, y consistentes
tambin con el comportamiento planteado de la estructura:

o Compromisos (con el dueo, y con la sociedad en general)
6 m
2.5 m
6 m
2.5 m
0.6 m
V
col
= 2 M
p
/ 2.5 V
col
= 2 M
p
/ 0.6
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


11
o Enseanza
o Materiales
o Estructuracin
o Clculo
o Diseo
o Aspectos Normativos
o Adiestramiento
o Construccin
o Inspeccin
o Mantenimiento
o Rehabilitacin





Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


12

2. COMPORTAMIENTO Y DISEO DE VIGAS DE CONCRETO REFORZADO

2.1 Concepto de Regiones Crticas

Inherente en el diseo del concreto reforzado por sismos es la habilidad de la estructura de formar un
mecanismo dinmico estable. Tales mecanismos se componen de tramos que se mantienen
esencialmente elsticos, ligados por regiones donde se concentran las deformaciones inelsticas. Estas
ltimas se pueden llamar regiones crticas, pues la suerte de la estructura en el rango inelstico
depende del comportamiento de ellas. Abajo se muestran varias formas de regiones crticas, tanto en
estructuras tipo prtico como en estructuras tipo muro.

Por ejemplo, una estructura tipo prtico forma un mecanismo involucrando rotaciones inelsticas
concentradas en los extremos de las vigas o columnas.



Un muro chato cortante normalmente forma un mecanismo en el cual las deformaciones inelsticas se
concentran en segmentos gobernados por corte.




Un muro alto cortante forma una rtula plstica en la base:

rotaciones inelasticas
concentradas
(rotulas plasticas)
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


13


Entonces, nuestro estudio involucra el comportamiento y diseo de regiones crticas. El
comportamiento depende de cmo se solicita:

o tipo de carga (P, M, V, T)
o tamao de carga
o historia de carga (montono verso cclico)


Consideremos un ejemplo simple que demuestra la importancia de historia de carga. Digamos que
investigamos el comportamiento tipo anclaje en traccin, de una varilla deformada en concreto:



Si P es monotnica, podemos proveerle una
d
suficiente para resistir cargas hasta la capacidad ltima
de la varilla. En tal caso, el comportamiento carga-deflexin (P-A) es esencialmente l del refuerzo
mismo:



rotacion inelastica
concentrada
P, A
d

P, A
d

P
t
P
A
P
t
P
t
P
A
P
A
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


14
Ahora supongmonos que la carga se aplica en forma cclica, sin alternarse por cero:


Si P es suficiente para producir deslizamiento significativo del extremo cargado de la varilla, el
concreto comenzar a deteriorarse all, reduciendo la longitud de embebido que provee anclaje
efectivo:



Mientras contina el ciclaje, este deterioro se va a propagar a lo largo de la varilla, hasta que el anclaje
se reduce a tal punto que la varilla se desprende:


Es de notarse que este comportamiento es completamente diferente al comportamiento bajo carga
monotnica.


Revisemos el comportamiento de una viga estticamente determinada, con suficiente refuerzo
transversal para que una falla brusca cortante no gobierne. El momento de diseo es
8
2
w
, y la
capacidad iguala o supera ese valor.

P
t
P
t
P, A
d

longitud
degradada
P
A
P
A
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


15




El momento crtico M
crtico
es el momento en la primera seccin en fallar:



Observaciones:

a) El agrietamiento por flexin ocurre muy temprano.

b) Si p > p
mn
(para evitar una falla brusca), las grietas se abren y la carga se incrementa.

c) Con acero de f
y
= 4200 y arriba, grietas anchas forman muy antes de la cedencia, resultando en
serviciabilidad disminuida.

d) En el rango de servicio, debemos reconocer los efectos de deformaciones lentas y de historia
de cargamento.

M
8
2
w
w
M
8
2
w
w
M
critico
A
primeras
grietas
grietas
anchas
cedencia
el comportamiento en esta region
es muy sensible a la cuantia y tipo
de refuerzo
1 2
3
4
M
usable
M
ultimo
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


16
e) Bajo solicitaciones severas, comportamiento pos-cedencia depende de la historia de carga, y
tambin de la cuanta y distribucin de refuerzo. Varios senderos son posibles:

1) La falla (definida como una disminucin brusca de capacidad) ocurre inmediatamente
al llegar al M
til
si p>p
balanceado
and V ~ 0.

2) Una falla ms lenta ocurre si p < p
balanceado
. Esta falla se acelera si la regin crtica est
sujeta a corte alto.

3) El rango de comportamiento inelstico til se extiende ms si p se mantiene bajo, si se
incluye algn refuerzo compresivo (p'), y si se proveen estribos cerrados.

4) La viga puede desarrollar momentos en exceso al M
til
con p bajo, con algn p', y con
amarres cerrados en pequeo espacio para confinar el concreto. En efecto, el concreto
acta para prevenir el pandeo local del refuerzo principal.


Porqu tenemos inters en el comportamiento pos-cedencia?

1) Queremos evitar una falla completa bajo solicitaciones extremas cuya probabilidad es pequea,
y tambin fallas de serviciabilidad que involucran cedencia significativa.

2) El comportamiento pos-cedencia influye la disipacin de energa, la cual es importante en
cuano a la respuesta dinmica se refiere.



Ahora consideremos el caso de una viga estticamente indeterminada:



Las capacidades en flexin pueden ajustarse cambiando las cantidades de refuerzo en las diferentes
secciones de la viga.

Preguntas:

1) Cul nivel de carga debe usarse para el diseo?

2) Cul distribucin de momentos debe usarse para el diseo?

3) Qu tan realista es, usar momentos elsticos en el rango de servicio? En el rango ltimo?

4) Cmo se debe distribuir el refuerzo longitudinal?

5) Es necesario el refuerzo compresivo?

w ,

A C B
w ,

A C B
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


17

2.2 Caractersticas Mecnicas de Materiales
Antes de estudiar el comportamiento de las regiones crticas, tenemos que investigar las caractersticas
mecnicas de sus materias primas, el acero de refuerzo y el concreto, tanto confinado como del estado
normal.

2.2.1 Acero de Refuerzo


El grfico de abajo muestra las caractersticas mecnicas del acero de refuerzo, bajo cargas
monotnicas.





Comentarios:

1) El esfuerzo de cedencia est por lo menos unor5% arriba del valor nominal, y a veces mucho
ms.

2) El esfuerzo de cedencia f
y
puede aumentarse hasta el 15% adicional, bajo altas tasas de
deformacin.

3) El f
y
puede incrementarse hasta f
ult
por endurecimiento por trabajo.

4) Entre ms alto sea el punto de fluencia, ms corto ser la zona plstica.


Bajo carga alterna, tenemos el siguiente comportamiento.

8400
7000
5250
4200
2800
1400
0.01 0.05 0.10 0.15
Grado 40 (2800)
Grado 60 (4200)
Grado 75 (5250)
0.12
carga monotonica
c
s
f
s
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


18



2.2.2 Concreto No Confinado





Comentarios:

1) f
cmx
ocurre en una deformacin unitaria constante de 0.0017 a 0.002.

2) Entre ms fuerte sea el concreto, ms rpidamente disminuye la resistencia despus de fcmax.

3)
) (mod 5 . 2
) ( 0 . 2
'
'
rotura de ulo f f
brasileNa prueba f f
c t
c t
=
=



4)
004 . 0 003 . 0
max
=
c
c

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


19

2.3 Relaciones Momento-Curvatura para Secciones de Concreto Reforzado

Usando los principios bsicos de la cinemtica (secciones planas), relaciones esfuerzo-deformacin, y
equilibrio, se pueden generar curvas de momento-curvatura, usando procedimientos estndar. Este
comportamiento involucra los rangos siguientes:



1) El concreto no est agrietado. El acero y el concreto se comportan linealmente.

2) El concreto esta agrietado por traccin, pero tanto como el acero, se comporta linealmente.

3) El acero cede.

4) El acero est en la plataforma de cedencia.

5) El acero comienza a endurecerse. Este tipo de relacin momento-curvatura presupone que la
seccin tiene poco refuerzo, o sea, que el comportamiento se controla por cedencia del acero
en lugar de aplastamiento del concreto.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


20

Ejemplo:

Usando los principios bsicos del anlisis de secciones de concreto reforzado, calcular el grfico de M-
o (momento-curvatura) para esta seccin:

f
m
' = 281 kg/cm
2


f
y
= 4200 kg/cm
2


recubrimiento = 4 cm

A
s
= 13.57 cm
2






1) Antes del Agrietamiento:

Usar la seccin transformada, no agrietada:

cm cm d
E
E
n
cm kg E
cm kg cm kg E
c
s
s
c
9 . 48 2 / 4 . 2 9 . 0 4 55
06 . 8
/ 10 04 . 2
/ 253122 / 281 15100
2 6
2 2
= =
= =
=
= =





cm y
y
A
y A
y
i
i i
67 . 28
57 . 13 ) 1 06 . 8 ( 55 30
9 . 48 57 . 13 ) 1 06 . 8 ( 2 / 55 55 30
=
+
+
=
=






Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


21
2
,
2 2
3
,
2
3
,
457404
) 67 . 28 9 . 48 )( 57 . 13 )( 1 06 . 8 ( ) 67 . 28 2 / 55 )( 55 ( 30
12
55 30
12
cm I
I
Ad
h b
I
na t
na t
na t
=
+ +

=
+ =



cm
cm kg cm
cm kg
cm
E f
y
cm T
cm
cm cm kg
c
I f
M
c r
nto agrietamie
na t r
nto agrietamie
/ 10 03 . 5
/ 281 15100 ) 67 . 28 55 (
/ 281 0 . 2
) 67 . 28 55 (
/
5 . 582
) 67 . 28 55 (
457404 / 281 0 . 2
6
2
2
4 2
,

=

=

= =
=


= =
c
o


2) Despus del Agrietamiento:

Usar la seccin transformada, agrietada. El eje neutro est en el centroide de la seccin
trasformada, agrietada:

( )
( )
cm kd
kd kd
cm kd cm kd
cm
A n kd d
kd
kd b
s
58 . 15
) 15 ( 2
) 5348 ) 15 ( 4 4 . 109 4 . 109
0 5348 ) ( 4 . 109 15
57 . 13 06 . 8 ) 9 . 48 (
2
30
) (
2
) (
2
2
2 2
=
+
=
= +
=
=
|
.
|

\
|


2
,
2
3
,
2
3
,
159248
1 9 . 48 )( 57 . 13 )( 06 . 8 (
2
58 . 15
) 58 . 15 ( 30
12
58 . 15 30
12
cm I
I
Ad
h b
I
a t
a t
a t
=
+
|
.
|

\
|
+

=
+ =



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


22
cm
cm cm kg
cm kg
I E
M
cm T M
a t c
ag
agrietada
agrietado
/ 10 45 . 1
159248 / 281 15100
10 5 . 582
5 . 582
5
4 2
3
,


= =
=
o



3) Punto de Cedencia


El eje neutro se mantiene en la misma posicin, hasta tener

( ) ( ) ( ) cm T cm cm kg cm I E M
cm
cm kd d
cm kg
cm kg
E
f
a t c y y
s
y
s
y
y s
= = =
=

=
=

= = =

2504 159248 / 281 15100 / 10 21 . 6


/ 10 21 . 6
58 . 15 9 . 48
00207 . 0
00207 . 0
/ 10 04 . 2
/ 4200
4 2 5
,
5
2 6
2
o
c
o
c c


Chequear que el concreto est todava en el rango elstico:

( )
2 4 2
4 5
/ 9 . 244 10 68 . 9 / 281 15100
10 68 . 9 ) 58 . 15 ( / 10 21 . 6
cm kg cm kg E f
cm cm kd
c c c
y c
= = =
= = =


c
o c

Este valor es ligeramente menor que f
c
'. Puede haber un pequeo error en suponer que el concreto
est completamente elstico, pero es aceptable.


4) Momento Nominal (ACI):

Usar el bloque rectangular equivalente de esfuerzos de compresin (ACI):


cm
cm c
c
cm
cm cm kg
cm kg cm
b f
f A
c
c b f f A
c
d f A M
c
y s
c y s
y s n
39 . 9
85 . 0
98 . 7
98 . 7
30 / 280 85 . 0
/ 4200 57 . 13
85 . 0
85 . 0
2
1
1
2
2 2
'
1
1
'
1
= = =
=


= =
=
|
.
|

\
|
=
|
|
|
|
|

cm T cm cm kg cm
c
d f A M
y s n
=
|
.
|

\
|
= |
.
|

\
|
= 2560
2
98 . 7
9 . 48 / 4200 57 . 13
2
2 2 1
|

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


23
Calcular la curvatura:

cm
cm c
cu
ACI
/ 10 19 . 3
39 . 9
003 . 0
4
= = =
c
o
En este punto, revisemos la deformacin unitaria en el esfuerzo:

012 . 0
68 . 9
68 . 9 9 . 48
003 . 0 = |
.
|

\
|
= |
.
|

\
|
=
c
c d
c s
c c

El acero apenas ha comenzado a endurecerse por deformacin, y la premisa del anlisis ACI
se cumple.



5) Comienzo del Endurecimiento por Deformacin:

Ver inmediatamente arriba.


Relacin Momento-Curvatura



Comentarios:

1) Usando el acero ms comn (f
y
= 4200 kg/cm
2
), tenemos una ductilidad de curvatura
significativa:

0
500
1000
1500
2000
2500
3000
0 0.00005 0.0001 0.00015 0.0002 0.00025 0.0003 0.00035
M
o
m
e
n
t
o


(
T
-
c
m
)
Curvatura (1/cm)
Momento - Curvatura
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


24
14 . 5
10 21 . 6
10 19 . 3
5
4
=

= =

y
ultima
o
o
u
o

2) Para el diseo ssmico, este comportamiento es casi ideal.

2.4 Efecto de Confinamiento Lateral del Concreto

2.4.1 Introduccin al Concepto del Confinamiento Lateral

En el ltimo clculo de arriba, vemos que la ductilidad de curvatura es la razn entre la ltima
curvatura y la curvatura de cedencia:

( )
( )
( )
( )

= =
y
y
ult
ult c
y
y
ult
ult c
y
ultima
kd d
kd
kd d
kd
c
c
c
c
o
o
u
o


Para aumentar la ductilidad de curvatura, lo ms til es aumentar la mxima deformacin unitaria del
concreto. No en trminos prcticos, no podemos hacer cambios significativos en los dems
trminos.

En los aos 20 del siglo pasado, ensayos en la Universidad de Illinois mostraron que la presencia de
presin lateral hidrosttica aumenta la resistencia de cilindros de concreto cargados en compresin, y
tambin aumenta la mxima deformacin unitaria.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


25


Ellos proponen que

lateral c confinado c
f f f 1 . 4
'
+ =


pues el confinamiento hidrosttico pone el concreto en estado de compresin tri-axial, previniendo
as el agrietamiento. El confinamiento hidrosttico es activo (no depende de la respuesta del
concreto).

El confinamiento que viene de estribos o espirales cerrados, en contraste, es pasivo. Como se
explica a continuacin, el confinamiento pasivo no acta hasta que el concreto comienza a agrietarse.
Consideren el confinamiento pasivo que ofrece un tubo de acero, puesto alrededor de un cilindro de
concreto. Cuando se le aplica una carga axial compresiva, el tubo de acero inicialmente no tiene
efecto alguno, hasta que el cilindro de concreto expande lateralmente contra l, debidos a los efectos
de Poissn. Los coeficientes de Poissn son muy semejantes para los dos materiales.



16 . 0
25 . 0
~
~
acero
acero
v
v


Mientras el esfuerzo compresivo aumenta en el concreto,
ste comienza a agrietarse internamente y expandirse
lateralmente, resultando en un aumento aparente de la
coeficiente de Poissn.



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


26


Cuando f
c
llega a unos 0.45 f
c
', el valor de vconcreto comienza a crecer, llegando a un valor de
aproximadamente 0.50 (igual que para un lquido) para f
c
= f
c
'.

Entonces, el tubo de acero puede comenzar a confinar el concreto, resistiendo la expansin lateral de
ste. No va a aumentar por mucho la capacidad del concreto, el cual ya est agrietado. Sin embargo,
s va a aumentar la mxima deformacin til.

2.4.2 Confinamiento por Estribos Cerrados o Espirales

Ahora digamos que en lugar de un tubo continuo, tenemos amarres cerrados.
.


Estos todava van a confinar pasivamente, aumentando la deformacin mxima del concreto. Los
primeros ensayos fueron llevados a cabo usando confinamiento por espiral es , que pueden confinar
muy eficazmente debido a su forma.
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


27


Como muestra la segunda figura, estribos cerrados no apoyados no pueden confinar tan eficazmente,
pues la presin del concreto hace doblar las varillas flexibles. Como resultado, la regin confinada
se restringe a una pequea parte del ncleo, y hay menos efecto beneficioso del confinamiento.


Debido a estos ensayos, se pensaba que los espirales, de por s, confinan mejor que los amarres
rectangulares. Sin embargo, investigaciones ms recientes han demostrado que amarres
rectangulares con el debido apoyo intermedio, pueden confinar ms o menos tan bien como los
espirales:



2.4.3 Relacin Esfuerzo-Deformacin para el Concreto Confinado

Con base en el aumento de deformacin til provisto por el confinamiento pasivo, se han propuesto
varias relaciones empricas entre esfuerzo y deformacin unitaria. Una relacin ampliamente usada
es la de Kent y Park. Se supone que los miembros son rectangulares, con amarres rectangulares. Sin
embargo, la relacin ha sido usada tambin para otras secciones.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


28


Mdulo: 002 . 0 ;
2
'
= =
o
o
c
T
f
E c
c


Traccin:
) / (
281
3 . 70
) lg / (
4000
1000
2
'
'
2
'
'
cm kg
f
f
f
pu libras
f
f
f
c
c
r
c
c
r
+
=
+
=


Compresin:


o c
c c < < 0

|
|
.
|

\
|

|
|
.
|

\
|
=
2
'
2
o
c
o
c
c c
f f
c
c
c
c



o c
c c >
Concreto No Confinado

El diagrama esfuerzo-deformacin desciende por la lnea recta
pasando desde (c
o
, f
c
') por (c
50u
, 0.50 f
c
'), donde

) / (
3 . 70
002 . 0 211 . 0
2
'
'
50
cm kg
f
f
c
c
u

+
= c

Se presume que no tiene resistencia pasada la deformacin
correspondiente a 0.20 f
c
'.

Concreto Confinado

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


29
La lnea recta desciende desde (c
o
, f
c
') por (c
50c
, 0.50 f
c
'), donde
h u c 50 50 50
c c c + =
c
50u
se define como arriba, y
h
s h
s
b
' '
50
4
3
p c =
donde
amarres entre espacio s
confinado concreto del ancho b
confinado concreto del volumen
l transversa refuerzo del volumen
h
s
=
=
=
' '
p

Se presume que el concreto mantiene 0.20 f
c
' para toda deformacin
unitaria pasada el punto donde la lnea descendiente llega a ese valor.


Ejemplo:

Calcular la curva esfuerzo-deformacin unitaria para el concreto en esta seccin.

2
2 '
/ 4200
/ 281
cm kg f
cm kg f
y
c
=
=


a) estribos cerrados de 12 mm @ 25 cm
b) estribos cerrados de 12 mm @ 10 cm


a) estribos cerrados de 12 mm @ 25 cm

3
50
'
'
50
10 67 . 3
3 . 70 281
281 002 . 0 211 . 0
3 . 70
002 . 0 211 . 0

+
=

+
=
u
c
c
u
f
f
c
c



( ) | |
006 . 0
25 ) 8 55 )( 8 30 (
) 8 55 ( 2 ) 8 30 ( 2 2 . 1
4
25
22 ) 4 ( 2 30
2
' '
=

+
= =
= =
= = =
cm
confinado concreto del volumen
l transversa refuerzo del volumen
cm amarres entre espacio s
cm cm cm confinado concreto del ancho b
s
h
t
p


0042 . 0
25
22
006 . 0
4
3
4
3
' '
50
= = =
h
s h
s
b
p c
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


30

0079 . 0 0042 . 0 00367 . 0
50 50 50
= + = + =
h u c
c c c



b) estribos cerrados de 12 mm @ 10 cm

3
50
'
'
50
10 67 . 3
3 . 70 281
281 002 . 0 211 . 0
3 . 70
002 . 0 211 . 0

+
=

+
=
u
c
c
u
f
f
c
c



( ) | |
015 . 0
10 ) 8 55 )( 8 30 (
) 8 55 ( 2 ) 8 30 ( 2 2 . 1
4
10
22 ) 4 ( 2 30
2
' '
=

+
= =
= =
= = =
cm
confinado concreto del volumen
l transversa refuerzo del volumen
cm amarres entre espacio s
cm cm cm confinado concreto del ancho b
s
h
t
p


0167 . 0
10
22
015 . 0
4
3
4
3
' '
50
= = =
h
s h
s
b
p c

0204 . 0 0167 . 0 00367 . 0
50 50 50
= + = + =
h u c
c c c


Las dos curvas se muestran abajo. Es de notarse el aumento de deformacin til debido al espacio
reducido entre amarres.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


31


2.5 Relaciones Momento-Curvatura para Vigas de Concreto Reforzado

2.5.1 Relaciones Tericas Momento-Curvatura


Usando la relacin de esfuerzo-deformacin desarrollada por Kent y Park para el concreto
confinado, se podra calcular curvas de momento-curvatura para tajadas de regiones crticas sujetas a
flexin. El comportamiento M-o de regiones crticas confinadas puede considerarse en las siguientes
etapas:

1) Hasta c
c
= c
o
= 0.002, el comportamiento es idntico al de secciones no confinadas.

2) Cuando la deformacin unitaria en la fibra extrema compresiva llega a c
c
= 0.003 a 0.004, el
concreto no confinado comienza a desconcharse. Este proceso se acelerar debido al plano
de debilidad creado por los amarres.

3) Debido a la prdida del concreto de la zona compresiva, el brazo interno de la seccin se
disminuye, as como la capacidad en flexin.

0
50
100
150
200
250
300
0 0.01 0.02 0.03 0.04 0.05 0.06
E
s
f
u
e
r
z
o
,

k
g
/
c
m
^
2
Deformacion Unitaria
Efecto de Confinamiento
confinamiento en 10 cm
25 cm
ningun confinamiento
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


32


4) Cuando el acero en traccin comienza a endurecerse, la capacidad en flexin de la seccin
comienza a subir, hasta exceder la capacidad de la seccin original.



Si queremos analizar el comportamiento exacto, podemos hacerlo. Pero como diseadores, nos basta
con observar que el comportamiento M-o es casi ideal y elasto-plstico , con una pequea prdida de
capacidad debido al desconchamiento del concreto no confinado.


2.5.2 Clculo de Relaciones Momento-Curvatura mediante Programas a
Computadora

Hay una variedad de programas a computadora capaces de calcular relaciones momento-curvatura
para vigas de concreto reforzado. Los programas siguen los pasos de abajo:

1) Se define la forma geomtrica de las secciones de concreto, tanto inicial como confinada.

2) Se define el arreglo del refuerzo longitudinal (ubicaciones y reas).

3) Se define la curva esfuerzo verso deformacin unitaria para el acero, posiblemente
incluyendo los efectos del endurecimiento por deformacin.

4) Se define la curva esfuerzo verso deformacin unitaria para el concreto, incluyendo los
efectos del confinamiento.

5) Se sujeta la seccin a una serie de gradientes de deformaciones unitarias. Cada gradiente
define la deformacin unitaria correspondiente en concreto y acero. Se divide
(internamente) la seccin en tajadas; se calcula el esfuerzo en cada tajada; se multiplica cada
esfuerzo por el rea de la tajada; y se calculan la fuerza axial y el momento flector
correspondientes.

6) Para llegar a una curva momento-curvatura para una fuerza axial definida, se puede o iterar
cambiando la ubicacin del eje neutro, o calcular varias combinaciones de fuerza axial y
momento e interpolar para la fuerza deseada. La primera alternativa (la iteracin) es a veces
difcil, pues la combinacin de una curva esfuerzo-deformacin unitaria para el acero que
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


33
asciende en el rango de endurecimiento por deformacin, y una curva esfuerzo-deformacin
unitaria para el concreto que desciende en el rango de desmoronamiento.


Un ejemplo de tal programa, RECONASANCE, se va a presentar en este curso. Tiene mltiples
ventajas, y una desventaja.

o Las ventajas incluyen una entrada de datos simple y transparente, soluciones robustas (no es
necesario iterar), y salida fcil de usar. El programa funciona con base en una serie de
macros en una hoja de clculo Excel. El programa calcula automticamente curvas de
esfuerzo-deformacin unitaria para el acero y para el concreto, incluyendo los efectos de
confinamiento.

o La desventaja es que el programa funciona solamente en unidades de libras, pulgadas, y kips,
por la razn de que sus macros internas usan aquellas unidades. Para usarlo en este curso,
hay que convertir la entrada a unidades de libras, pulgadas, y kips, y luego convertir la salida
a las unidades deseadas.



Ejemplo:

Usando el programa RECONASANCE, calcular la curva esfuerzo-deformacin unitaria para el
concreto en esta seccin.

2
2 '
/ 4200
/ 281
cm kg f
cm kg f
y
c
=
=


a) estribos cerrados de 12 mm @ 25 cm
b) estribos cerrados de 12 mm @ 10 cm



Primero, hay que convertir las unidades:

Cantidad unidades de
kg, cm
unidades de
libras, pulgadas, kips
t 55 cm 21.65 pulg
b 30 cm 11.81 pulg
recubrimiento 4 cm 1.5 pulg
d 48.9 cm 19.25 pulg
d' 6.1 cm 2.40 pulg
s 10 cm 4 pulg
A
s
15.20 cm
2
2.36 pulg
2

A
s
' 7.63 cm
2
1.18 pulg
2

f
y
4200 kg/cm
2
60 kips/pulg
2

f
c
' 281 kg/cm
2
4000 libras/pulg
2

b'' 22 cm 8.81 pulg
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


34
p
s

( ) | |
015 . 0
10 ) 8 55 )( 8 30 (
) 8 55 ( 2 ) 8 30 ( 2 2 . 1
4
2
=

+ cm
t
0.015


Obtenemos la siguiente respuesta, en unidades de kips y pulgadas:




En el programa RECONASANCE, vamos a Data for Plots, y obtenemos los valores:




0
320.8
641.6
962.4
1283.2
1604
1924.8
2245.6
2566.4
2887.2
3208
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00
M
o
m
e
n
t
(
k
i
p
-
i
n
.
)
Curvature * 10^3 (rad/in.)
Moment-Curvature Response
Initial Section Confined Section
c
cmax
c (in.) M (kip-in.)
o x 10
3
(rad/in. )
0.00 0.00 0.00 0.0000
0.0005 6.01 1292.75 0.0832
0.001 6.14 2416.44 0.1630
0.002 3.72 2503.56 0.5373
0.0025 3.51 2578.07 0.7136
0.003 3.51 2692.27 0.8544
0.0035 3.57 2780.36 0.9810
0.004 3.65 2849.31 1.0969
Moment-curvature data points for initial section
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


35


Convertimos los valores a unidades de T-cm, y los ponemos en una hoja de clculo para graficar:



c
cmax
c (in.) M (kip-in.)
o x 10
3
(rad/in. )
0.00 0.00 0.00 0.0000
0.0005 6.16 1024.93 0.0812
0.001 6.36 1943.96 0.1573
0.002 3.80 2338.93 0.5259
0.0025 3.25 2422.08 0.7689
0.003 3.12 2585.94 0.9627
0.0035 3.22 2667.23 1.0881
0.0040 3.32 2735.85 1.2045
0.0045 3.43 2794.24 1.3121
0.0050 3.54 2844.94 1.4145
0.0060 3.75 2927.06 1.6018
0.0070 3.95 2989.61 1.7711
0.0080 4.16 3037.07 1.9254
0.0090 4.36 3072.33 2.0667
0.0100 4.55 3097.42 2.1962
0.0200 6.34 3118.52 3.1565
0.0300 7.64 3098.98 3.9251
0.0400 8.53 3125.27 4.6903
0.0500 9.20 3157.02 5.4367
Moment-curvature data points for confined section
c
cmax c (in.) M (kip-in.) o x 10
3
(rad/in. ) o x 10
3
(ra
M (kip-in.) M (kip-in.) o x 10
3
(ra
M (T-cm) M (T-cm)
0.00 0.00 0.00 0.0000 0.0000 0.00 0.0000 0
0.0005 6.01 1292.75 0.0832 0.0832 1292.75 0.0832 1489.29
0.001 6.14 2416.44 0.1630 0.1630 2416.44 0.1630 2783.821
0.002 3.72 2503.56 0.5373 0.5373 2503.56 0.5373 2884.182
0.0025 3.51 2578.07 0.7136 0.7136 2578.07 0.7136 2970.018
0.003 3.51 2692.27 0.8544 0.8544 2692.27 0.8544 3101.584
0.0035 3.57 2780.36 0.9810 0.9810 2780.36 0.9810 3203.067
0.004 3.65 2849.31 1.0969 1.0969 2849.31 1.0969 3282.496
Moment-curvature data points for initial section 0.0000 0.00 0.0000 0.00
0.0812 1024.93 0.0812 1024.93
0.1573 1943.96 0.1573 1943.96
c
cmax c (in.) M (kip-in.) o x 10
3
(rad/in. )
0.5259 2338.93 0.5259 2338.93
0.00 0.00 0.00 0.0000 0.7689 2422.08 0.7689 2422.08
0.0005 6.16 1024.93 0.0812 0.9627 2585.94 0.9627 2585.94
0.001 6.36 1943.96 0.1573 1.0881 2667.23 1.0881 2667.23
0.002 3.80 2338.93 0.5259 1.2045 2735.85 1.2045 2735.85
0.0025 3.25 2422.08 0.7689 1.3121 2794.24 1.3121 2794.24
0.003 3.12 2585.94 0.9627 1.4145 2844.94 1.4145 2844.94
0.0035 3.22 2667.23 1.0881 1.6018 2927.06 1.6018 2927.06
0.0040 3.32 2735.85 1.2045 1.7711 2989.61 1.7711 2989.61
0.0045 3.43 2794.24 1.3121 1.9254 3037.07 1.9254 3037.07
0.0050 3.54 2844.94 1.4145 2.0667 3072.33 2.0667 3072.33
0.0060 3.75 2927.06 1.6018 2.1962 3097.42 2.1962 3097.42
0.0070 3.95 2989.61 1.7711 3.1565 3118.52 3.1565 3118.52
0.0080 4.16 3037.07 1.9254 3.9251 3098.98 3.9251 3098.98
0.0090 4.36 3072.33 2.0667 4.6903 3125.27 4.6903 3125.27
0.0100 4.55 3097.42 2.1962 5.4367 3157.02 5.4367 3157.02
0.0200 6.34 3118.52 3.1565
0.0300 7.64 3098.98 3.9251
0.0400 8.53 3125.27 4.6903
0.0500 9.20 3157.02 5.4367
Moment-curvature data points for confined section
0
500
1000
1500
2000
2500
3000
3500
0.0 1.0 2.0 3.0 4.0 5.0 6.0
M
o
m
e
n
t
o
,

T
-
c
m
Curvatura, rad / cm
Momento - Curvatura
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


36
Finalmente, graficamos los resultados en unidades de T y cm.



2.6 Relaciones Tericas Momento-Rotacin

Ahora queremos considerar el comportamiento momento-rotacin que resulta de la relacin
momento-curvatura. O sea, dado este comportamiento de tajada, cmo ser el comportamiento de
una regin crtica que tiene longitud apreciable?

Claramente, podramos obtener la relacin M-u integrando la curva M-o sobre el largo de la regin
crtica. Pero eso despreciara el posible efecto de algunos factores muy importantes:

1) pandeo del acero longitudinal;

2 ) efecto del corte; y

3) efecto de cargas alternas

Ahora vamos a considerar estos factores.


2.6.1 Pandeo del Acero Longitudinal

Una vez perdido el recubrimiento en la zona compresiva, el acero compresivo no est restringido
contra e l pandeo. En efecto, este acero est arriostrado lateralmente en intervalos por los estribos.
Pero el acero compresivo todava puede pandearse, dado este largo crtico.

0
500
1000
1500
2000
2500
3000
3500
0.0 1.0 2.0 3.0 4.0 5.0 6.0
M
o
m
e
n
t
o
,

T
-
c
m
Curvatura, rad / cm
Momento - Curvatura
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


37


Este pandeo trae consigo muchas consecuencias graves:

1) se reducir la efectividad del confinamiento provisto por el acero compresivo longitudinal;

2) se reducir la capacidad compresiva del acero longitudinal, bajando as la capacidad en
flexin de la seccin; y

3) el acero pandeado estar muy sensible a la fractura, debida a las altas deformaciones locales.

Consideremos cmo podemos prevenir o demorar este pandeo:



??
64
var
4
var
var
=
=
>
illa
illa
y illa cr
I
D
I
f A P
t


Si queremos obtener buen comportamiento M-u, debemos prevenir el pandeo an despus de que las
varillas longitudinales se han fluido. En esa etapa, tendrn el mdulo de endurecimiento.

P ser por lo menos igual a A
varilla
f
y
.

??
64
var
4
var
var
=
=
>
illa
illa
y illa cr
I
D
I
f A P
t

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


38
( )
( )
( )
y
ento endurecimi
h
y
ento endurecimi
h
h
ento endurecimi y
h
illa ento endurecimi
cr y illa
f
E
k
D
s
D
f
E
s k
s k
D E f D
s k
I E
P f A
4
16
1
64 4
2
2
2
2
4 2 2
2
var
2
var
t
t
t
t
t
t
s
s
s
= s


k
D
s
f
E
k
D
s
cm kg E
cm kg f
h
y
ento endurecimi
h
ento endurecimi
y
4
5
4
/ 10 06 . 1
/ 4200
2 6
2
t
t
s
s
=
=


k
D
s
f
E
k
D
s
cm kg E
cm kg f
h
y
ento endurecimi
h
ento endurecimi
y
4
5
4
/ 10 06 . 1
/ 4200
2 6
2
t
t
s
s
=
=


k = 1 (apoyo simple): s
h
s 4 D
k = 1/2 (apoyo empotrado): s
h
s 8 D

La expansin lateral del concreto confinado probablemente va a causar el pandeo eventualmente,
pero podemos demorarlo usando s
h
s 8 D.


2.6.2 Efectos del Corte

Si tenemos una viga que forma parte de un prtico sujeto a deformaciones inelsticas debido a l a
accin de un sismo fuerte, debemos anticipar que la viga experimentar un corte mximo como se
indica abajo:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


39


Si rtulas plsticas se forman en los dos extremos de la viga, el corte mximo ser



En este caso Mult Mn, si tenemos acero ordinario. Con acero de fy = 4200, debemos preveer e l
aumento de M debido a l endurecimiento (Mult Jb 1.25 Mn). Debemos calcular Mn usando el
actual fy .




Segn el ACI 318-08,

s c n
V V V + =

En la realidad, el mecanismo de resistencia es ms complicado. Antes de agrietarse por corte, la viga
resiste monolticamente. Despus, la resistencia proviene de una accin de puntales y tensores, en la
cual los estribos y varillas longitudinales actan en traccin, y el concreto acta como puntales
embebidos, y actan en compresin.

El ACI 318-08 toma por entendido que despus del agrietamiento diagonal, la resistencia del
concreto V
c
se mantiene por lo menos al nivel correspondiente al primer agrietamiento cortante, y
que la accin de armadura (puntales y tensores) puede simplificarse a incluir solamente los estribos.

|
.
|

\
|
=
s
|
|
.
|

\
|
+ =
=
s
d
f A V
d b f d b
M
d V
f V
d b f V
y v s
w c w
u
u
w c c
w c c
' '
'
93 . 0 176 50 . 0
53 . 0
p

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


40

2.6.3 Efecto de Cargas Alternas


Este tipo de solicitacin va a degradar la resistencia a flexin de la viga, y tambin su resistencia a
corte.

Efecto sobre la resistencia flexural:

Al cargarse en un sentido, se forman grietas por flexin.




Al cargarse en el sentido contrario, se forman nuevas grietas en el
otro lado.



Debido al deterioro de adherencia en las regiones agrietadas, las grietas pre-existentes no van a
cerrarse completamente cuando el momento se quita. Entonces, cuando el momento se aplica en el
sentido contrario, el concreto no est en compresin, hasta que el acero en compresin ha sido
comprimido lo suficiente para cerrar las grietas. Al cargarse de nuevo, entonces, la seccin tiene la
rigidez en flexin de slo la contribucin del acero en traccin y compresin, la cual es mucho ms
flexible que la seccin transformada agrietada.



Cuando el momento ha aumentado suficientemente para cerrar las grietas por flexin en la zona de
compresin, la rigidez de la seccin comienza a aumentarse otra vez.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


41


Cuando se aplica el momento en el sentido contrario otra vez (o sea, en el sentido original),- las
grietas por flexin en el otro lado, causarn una repeticin de este fenmeno. El resultado es un
estrangulamiento de los lazos histerticos, una prdida de rigidez, y una prdida de capacidad de
disipacin de energa.


2.6.4 Efecto sobre la Resistencia Cortante

En la presencia de corte, las grietas por flexin que forman en los dos sentidos, estn inclinadas.



En la zona agrietada, la viga se deforma por flexin, y tambin por corte. En el modelo de puntales y
tensores, los estribos se van a estirar, dando as mucha flexibilidad cortante. El resultado es de
aumentar ms an el estrangulamiento de los lazos histerticos:


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


42




Degradacin del concreto en esta regin provoca a un deslizamiento de un lado de la zona agrietada,
con respecto al otro. El resultado es una falla por "corte deslizante.




En resumen, hemos visto que el comportamiento en flexin de una regin crtica, ser perjudicado
por la posibilidad de pandeo de las varillas longitudinales, por el efecto de cargas alternas, y por el
efecto de corte. El uso de estribos cercanamente colocados, no slo demora el pandeo, sino tambin
reduce las deformaciones cortantes en las regiones crticas.


2.7 Relacin Terica Carga-Desplazamiento para el Concreto Confinado

Una vez diseada una seccin viga para capacidad inelstica de rotacin, se puede estimar el
correspondiente comportamiento carga-desplazamiento de tal viga.


El comportamiento momento-curvatura es as:



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


43
Se puede idealizar como elasto-plstico:



y
al no
y
y
elastico
M
M
EI
o o
min
~ =


Hasta el comienzo de la fluencia, la relacin P-A es lineal y elstica:



Por momento-rea,

I E
L P L L
EI
PL
3 3
2
2
3
=
|
.
|

\
|
|
.
|

\
|
= A

Tan pronto como el momento de empotramiento llega a My (o Mp), una rtula plstica se forma all.
La variacin realista a lo largo de la viga es asi:



Si la viga fuera idealmente elasto-plstica, la variacin de curvatura sera as:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


44

Endurecimiento por deformacin en el acero longitudinal extiende el largo de la rtula plstica:

rotacin adicional debido al endurecimiento por trabajo






Para conveniencia, la rotacin adicional debido a la fluencia muchas veces se trata como si fuera
uniforme sobre un largo idealizado
p
, y puede considerarse aparte de la rotacin elstica:



curvatura elstica


rotacin plstica




efectos combinados






( )
|
|
.
|

\
|
+ = A
|
|
.
|

\
|
+
|
.
|

\
|
|
.
|

\
|
= A
2 3
2 3
2
2
1
3
p
p
p
p y ult y
L
I E
L P
L
L
L

u
o o o


Si L
p
<< , esto se simplifica a
L
L
I E
L P
p
p
u
u
~ A
+ = A
3
3

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


45

Para calcular A, necesitamos saber up. Dos enfoques general estn disponibles. Cada enfoque da la
rotacin plstica en un lado de una seccin crtica (punto de momento mximo). Por ejemplo, en el
voladizo de arriba, la viga se termina en la seccin crtica:



En contraste, la viga de abajo contina por la seccin crtica:


2.7.1 Enfoque Terico


2
d
p
=
o
ult
se calcula usando curvas esfuerzo-deformacin unitaria para concreto confinado, y valores
realistas de k y c
cult
.

( )
05 . 0
2 3 . 0
03 . 0
2
~
|
.
|

\
|
=
|
.
|

\
|
=
=
p
p
ult
p
p p p
d
d
d
kd
ult c
u
u
c
u
o u




2.7.2 Enfoques Empricos

Los enfoques empricos calculan la rotacin plstica disponible mediante relaciones derivadas de
ensayos. Una muy usada es la de Mattock y Corley.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


46


Las relaciones empricas dan resultados semejantes a los que se obtienen por el enfoque terico.


2.7.3 Efecto del Agrietamiento Diagonal sobre u
p


Considerar el voladizo de arriba:



Calculamos el esfuerzo en traccin en el acero longitudinal en la Seccin B-B:

jd
s P
f A
M
s s
A
) (
0
A +
=
=



Si no fuera por las grietas inclinadas, el esfuerzo en traccin en el acero longitudinal en la Seccin B-
B sera simplemente

jd
P
f A
s s

=

Es decir, el efecto del agrietamiento inclinado es de correr el diagrama de momentos

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


47


El largo de la viga sobre el cual el acero longitudinal se fluye (y por consiguiente el largo de la rtula
plstica) se aumenta en forma significativa. Este aumento puede produce un aumento en la
capacidad de rotacin plstica.


2.8 La Ductilidad como Medida de Absorcin y Disipacin de Energa

Las investigaciones tericas y experimentales de estructuras sujetas a sismos fuertes han mostrado
que los niveles de fuerzas en tales estructuras (es decir, las fuerzas requeridas de diseo) pueden ser
muy altos, si la estructura tiene que permanecer elstica.

En contraste, si la estructura (o sus regiones crticas) se permite pasar por deformaciones inelsticas,
los niveles requeridos de fuerzas son mucho menores.

En otras palabras, si las regiones crticas de una estructura pueden disipar energa mediante
deformaciones inelsticas, los miembros pueden disearse por fuerzas mucho menores que si la
estructura fuera elstica. Esto ofrece claras ventajas econmicas, con tal de que las regiones crticas
puedan deformarse inelsticamente (deformaciones cclicas alternantes) sin perder mucha capacidad.

Definamos unos trminos importantes:

La disipacin de energa es el rea barrida dentro de un lazo histertico:


disipacin de energa








La absorcin de energa es el rea bajo solamente la curva de cargamento:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


48


La diferencia entre disipacin y absorcin de energa no es muy grande por una seccin de concreto
reforzado con refuerzo convencional. Puede ser muy grande, sin embargo, para una seccin de
concreto pretensado:


Digamos que tenemos una seccin de concreto reforzado cuyo comportamiento M-o se puede
idealizar como elasto-plstico:


Mediante esta idealizacin bilineal, tanto la disipacin como la absorcin de energa puede
expresarse fcilmente en trminos de la ductilidad de curvatura, definida como la razn de la
curvatura ltima dividida por curvatura de cedencia:


y
o
o
u
o
max





Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


49






Absorcin de Energa
( )
|
.
|

\
|
=
+ =
2
1
2
max
o
u o
o
o o
y y
y y
y y
M
M
M


Disipacin de Energa =
( )
( ) 1
max
=
=
o
u o
o o
y y
y y
M
M


Mayor ductilidad da lugar a:

1) mayor absorcin y disipacin de energa; y
2) mayor capacidad para redistribucin inelstica de momentos.



2.9 Principios Bsicos del Diseo de Regiones Crticas de Vigas de Concreto Reforzado
Hemos visto que el uso del acero de f
y
= 4200 kg/cm
2
hace posible el diseo de regiones crticas
capaces de soportar varios ciclos de carga alterna, con ductilidades locales de rotacin mayores que 4
o 5. Sin embargo, es preciso averiguar el actual punto de cedencia del acero a usarse. Muchas veces,
se piensa que el uso de acero de alta resistencia, siendo especificado el ordinario, da mayor margen
de seguridad al edificio. Esto es completamente errneo. La verdad es que para el acero
longitudinal, el uso de acero de alta resistencia en reemplazo al ordinario, perjudica al edificio de
muchas maneras:

a) Se aumenta la traccin que se puede desarrollar en las varillas longitudinales, lo que puede
provocar una falla frgil del miembro (por compresin) bajo momentos flectores, o una falla
por desprendimiento de anclaje;

b) Se aumenta la capacidad a flexin de los miembros, lo que aumenta el corte mximo que
estos tienen que resistir. Esto puede provocar una falla frgil (por corte) del miembro;

c ) Se disminuye la ductilidad local disponible de las regiones crticas, debido a lo corta que es
la plataforma de cedencia del acero de alta resistencia; y

d) Se pierde la habilidad de soldar fcilmente.


Sea cual sea el tipo de acero, algunas reglas generales ayudan mucho a proveer ductilidades locales
rotacionales del orden de 4 o 5 en regiones crticas:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


50
1) Mantener p ~ 3/8 p
balanceado
~ 0.01. Esto no solo ayuda a aumentar la ductilidad (ver arriba),
sino tambin a evitar el congestionamiento de las varillas. Esta sugerencia puede dificultar el
uso de losas planas.

2) Mantener p' ~ 0.5 p en las regiones crticas. Esto no solamente aumenta la ductilidad, sino
tambin mejora la habilidad del edificio para redistribuir sus acciones internas, despus de la
cedencia inicial, y adems aumenta la integridad general de la estructura.

3) Disear para el corte mximo posible. Para evitar en lo posible una falla frgil por corte,
hay que disear las regiones crticas para el mximo corte producido por las cargas
distribuidas a lo largo de la viga, ms el corte producido por la formacin de rtulas plsticas
en los extremos de la viga, calculado con base en el punto de cedencia probable del acero
longitudinal.

4) Calcular los anclajes usando f
y
probable.

5) Usar estribos cerrados con s s 20 cm.
Esto sirve muchos propsitos:

a) El confinamiento aumentar la ductilidad disponible. Se debe usar como mnimo
equivalente a estribos cerrados de 12 mm cada 20 cm para vigas tpicas.

b) Este espacio cercano previene o atrasa el pandeo del acero longitudinal.

e) Los estribos aumentan la resistencia a corte.


2.10 El Diseo Instantneo de Vigas de Concreto Reforzado

Los fundamentos del comportamiento de vigas de concreto reforzado expresados en esta seccin,
pueden encapsularse en unos procedimientos generales de diseo de tales vigas:

Primero, considerar las cargas. Para mdulos tpicos (distancias entre ejes de columnas) de 6 metros,
una losa de concreto reforzado tendra un espesor necesario, gobernado por deflexiones, de unos 20
cm.

Carga muerta:

losa de 20 cm 500 kg/m2
divisorios 100 kg/m2
total 600 kg/m2

Carga viva:

250 kg/m2, reducida por rea tributaria 200 kg/m2

( ) ( )
2 2 2 2
/ 0 . 1 / 1040 / 200 6 . 1 / 600 2 . 1 m T m kg m kg m kg q
u
~ = + =

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


51
Suponiendo losas de una direccin (conservador),

m T m m T w
u
/ 6 6 / 0 . 1
2
= =

Para columnas cuadradas de 60 cm, la luz clara es 5.40 m.

( ) ( )
cm kg
cm kg M M
M
cm kg m kg
m m kg w
M
u u requerido
n
u
u
=

= = =
= =

= ~
6
6
6
2
2
'
max
10 94 . 1
9 . 0
10 75 . 1
9 . 0
10 75 . 1 17496
10
40 . 5 / 6000
10
o




Si usamos una viga con una profundidad total de 50 cm, un ancho de 30 cm, y 4 varillas,

( )
2
2
6
69 . 11
9 . 0 6 50 / 4200
10 94 . 1
cm
cm cm cm kg
cm kg
jd f
M
A
y
requerido
n requerida
s
=


=

=

Usar 4 varillas de #6 (19 mm).


Colocar las varillas usando la configuracin estndar repetitiva que se muestra aqu:





Varilla (EEUU) Varilla (SI) rea (cm
2
)
No. 4 12 mm 1.29
No. 5 16 mm 2.00
No. 6 19 mm 2.84
No. 7 22 mm 3.87
No. 8 25 mm 5.10
No. 9 29 mm 6.45
No. 10 32 mm 8.22
No. 11 36 mm 10.1

2 varillas
2 varillas
2 varillas
2 varillas
2 varillas 2 varillas
1 varilla
luz ~ 6 m; dimensiones tipicas de viga 30 cm por 50 cm; varillas longitudinales 19 mm; estribos cerrados de 12 mm en 20 cm
4
'
tipica
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


52

3. COMPORTAMIENTO Y DISEO DE COLUMNAS DE CONCRETO REFORZADO


3.1 Prlogo sobre Semejanzas y Diferencias entre Requisitos para Columnas y para Vigas
El diseo de columnas capaces de trabajar bien en el estado lmite del colapso, involucra ms o
menos los mismos principios que el diseo de las vigas, pero se complica un poco por la presencia de
carga axial.

Adems de eso, hay ciertas diferencias importantes entre los papeles de vigas y columnas. Digamos
que una viga tiene rtulas plsticas en los dos extremos. Aunque estas regiones crticas estn
severamente daadas, la viga puede soportar un peso apreciable, considerndose simplemente
apoyada. El prtico habr perdido mucha rigidez, y mucha resistencia horizontal, pero no habr
perdido mucha capacidad vertical. Puede soportar las cargas de gravedad despus de un sismo,
mientras hacen las reparaciones. En una columna, en contraste, si las rtulas plsticas forman en las
columnas, eso perjudica la capacidad, tanto vertical como horizontal, del prtico. Si daos son
severos, es posible que el prtico no pueda soportar cargas de gravedad, despus del sismo. Por eso,
es importante tratar de minimizar los daos a las columnas.

La manera ms fcil de hacer eso es minimizar la formacin de rtulas plsticas en las columnas,
aunque (como se ve abajo) no es posible eliminarlas por completo. Adems de cumplir la meta de
proteger las columnas, la estrategia de promover a que las rtulas se formen en las vigas en vez de
las columnas, conduce a mecanismos con mayor nmero de rtulas, y ms habilidad para disipar
energa.




Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


53
Aunque la estrategia de promover a que las rtulas se formen en las vigas no garantiza que pase eso,
es buen enfoque. En general, hay que asegurar que la capacidad en flexin de las columnas en cada
conexin viga-columna, exceda la de las vigas por cierto margen.



3.2 Diagrama de Interaccin Momento-Fuerza Axial para Columnas de Concreto
Reforzado, Seccin Inicial
Usando los mismos principios que para vigas, podramos calcular curvas M-o para secciones sujetas
a carga axial en adicin a momento flector.

Pero resulta de ms utilidad, un diagrama de interaccin momento-carga axial (M-N). Nos interesa
calcularlo usando c
c
= 0.003. Revisemos los principios bsicos mediante un ejemplo:

Ejemplo: Calcular el diagrama de
interaccin M para esta seccin de
columna. UsarE~ . 0 . 003 , el bloque
de esfuerzos ACI, f ~ = 281 kg/cm2 ,
fy = 2800 , recubrimiento = 4 cm ,
estribos E ~ 12.

( )
cm cm cm d
cm cm A
cm
cm
cm cm d
illa
2 . 43 8 . 6 50
04 . 8 2 . 3
4
8 . 6
2
2 . 3
2 . 1 4
2 2
var
'
= =
= =
= + =
t


Hay que calcular cuatro puntos
crticos:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


54



Punto A (Compresin Pura):

( )
( )
T N
kg illa cm illas cm cm kg N
f A A A f N
y total acero total acero gruesa c
916
4200 04 . 8 10 var / 04 . 8 var 10 50 / 281 85 . 0
85 . 0
2 2 2 2
'
=
+ =
+ =


Punto B (Punto Balanceado):

Ubicar eje neutro:

( )
cm cm c
d d c
E
f
d
c
d
c
c d c
c d c
s
y
y
y
y
62 . 25 2 . 43 59 . 0
59 . 0
003 . 0
10 04 . 2
4200
003 . 0
003 . 0
003 . 0
003 . 0
003 . 0
003 . 0 003 . 0
003 . 0
6
= =
=
|
.
|

\
|
+

=
|
|
.
|

\
|
+
=
+
=
=

=
c
c
c


( )
( )
2 '
2 6 '
'
' '
/ 4200
/ 4496 10 04 . 2
62 . 25
8 . 6 62 . 25
003 . 0
003 . 0
cm kg f f
f cm kg
cm
cm
f
E
c
d c
E f
y s
y s
s s s s
= =
> =

= = c

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


55
( ) ( ) ( )
T N
cm kg cm N
f A c b f f A N
T C N
y s c s s
07 . 260
4200 04 . 8 5 62 . 25 85 . 0 50 281 85 . 0 / 4200 04 . 8 5
85 . 0
2 2
1
' ' '
=
+ =
+ =
=
|


Tomando momentos alrededor del centroide plstico, tenemos

( ) ( ) ( )
cm T M
cm T cm T M
M
c h
c b f d
h
f A d
h
f A M
c s s y s
=
+ =
|
.
|

\
|
+ =
|
.
|

\
|
+ |
.
|

\
|
+ |
.
|

\
|
=
816 , 9
670 , 3 146 , 6
2
62 . 25 85 . 0
25 62 . 25 85 . 0 50 281 85 . 0 2 4200 80 . 6 25 04 . 8 5
2 2
85 . 0
2 2
1
1
' ' ' ' '
|
|



Punto C (Momento Puro):

Variar la ubicacin del eje neutro para satisfacer la condicin de N = 0.


Suponer que
y s
f f <
'


y s
f f =






( )
( )
( ) ( ) ( )
( ) ( )( )
( )
cm c
c
c c
c c c
c
c
c
cm kg cm N
c
d c
E f
f A c b f f A N
T C N
s s
y s c s s
88 . 10
151 , 10 2
963 , 672 , 1 151 , 10 4 416 , 43 416 , 43
0 963 , 672 , 1 416 , 43 151 , 10
0 840 , 168 151 , 10 963 , 672 , 1 024 , 246
0 4200 04 . 8 5 85 . 0 50 281 85 . 0
8 . 6
/ 10 04 . 2 003 . 0 04 . 8 5
003 . 0
85 . 0
2
2
2
2 6 2
'
'
1
' ' '
=
+
=
= +
= +
= +

=
+ =
=
|

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


56
( )
( )
2 2 2 6 '
'
'
/ 200 , 4 / 294 , 2
88 . 10
8 . 6 88 . 10
/ 10 04 . 2 003 . 0
003 . 0
cm kg f cm kg cm kg f
c
d c
E f
y s
s s
= < =

=


( ) ( ) ( )
( )
T N
cm T cm T cm T M
cm cm cm kg
cm cm kg cm M
c h
c b f d
h
f A d
h
f A M
c s s y s
0
002 , 7 250 , 2 751 , 4
2
88 . 10 85 . 0
25 88 . 10 85 . 0 50 / 281 85 . 0
80 . 6 25 / 294 , 2 4200 04 . 8 5
2 2
85 . 0
2 2
2 2
2 2
1
1
' ' ' ' '
=
= + =
|
.
|

\
|
+
+ =
|
.
|

\
|
+
|
.
|

\
|
+
|
.
|

\
|
=
|
|


Punto D (Traccin Pura):

T N
cm kg cm N
f A N
y total acero
7 . 337
/ 4200 04 . 8 10
2 2
=
=
=


Resumen de Puntos

Descripcin M
n
, T-cm P
n
, T
compresin pura 0 916
punto balanceado 9,828 260
momento puro 7,002 0
traccin pura 0 -338


Abajo se muestra el correspondiente diagrama de interaccin momento-fuerza axial.
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


57



3.3 Ductilidad de Curvatura en Funcin de Fuerza Axial

Ahora, calculamos las curvaturas (ltima y de cedencia), y as cal cular la ductilidad disponible de
curvatura, en funcin de fuerza axial.


Punto A (Compresin Pura):

1 0 = = =
o
u o o
y ult



Punto B (Punto Balanceado):

Puesto que el punto balanceado est definido por
y s
c c = ,
1 = =
o
u o o
y ult



Punto C (Momento Puro):

cm
cm c
cu
ult
/ 10 76 . 2
88 . 10
003 . 0
4
= = =
c
o

-600
-400
-200
0
200
400
600
800
1000
0 2000 4000 6000 8000 10000 12000
P
n

,

T
M
n
, T-cm
Diagrama de Interaccion Momento - Fuerza Axial
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


58
Ahora hay que determinar la ubicacin del eje neutro en el punto de cedencia, suponiendo que el
concreto se comporta linealmente, usando la seccin agrietada trasformada, e incluyendo el acero
compresivo.

( ) ( )
( ) ( ) ( )
( )
( ) ( )
67 . 3
10 53 . 7
10 76 . 2
10 53 . 7
86 . 15 2 . 43
/ 10 04 . 2
/ 4200
86 . 15
) 25 ( 2
15927 ) 25 ( 4 8 . 607 8 . 607
0 927 , 15 8 . 607 25
0 . 324 13997 1930 6 . 283 25
04 . 8 5 06 . 8 ) 2 . 43 ( 8 . 6 04 . 8 5 1 06 . 8
2
50
) ( 1
2
) (
5
4
5
2 6
2
2
2
2
2 ' 2 2
' '
=

= =
=

|
|
.
|

\
|

|
|
.
|

\
|
=

=
=
+
=
= +
= +
= +
= + |
.
|

\
|

y
ult
s
y
y
y
s s
cm cm
cm kg
cm kg
kd d
E
f
kd d
cm kd
kd kd
kd kd kd
cm kd cm kd cm kd
cm
A n kd d d kd A n
kd
kd b
o
o
u
c
o
o




Resumen de Puntos

Descripcin ductilidad de curvatura P
n
, T
compresin pura 1 916
punto balanceado 1 260
momento puro 3.67 0


En el grfico de abajo, se muestra la ductilidad de curvatura en funcin de la carga axial.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


59


3.4 Diagrama de Interaccin Momento-Fuerza Axial para Columnas de Concreto
Reforzado, Seccin Confinada

Para tener una idea del efecto de la prdida de recubrimiento sobre el diagrama M-N, podemos
calcularlo de nuevo, usando solamente la seccin confinada:

cm d
cm d
8 . 2
2
2 . 3
2 . 1
2 . 39
2
2 . 3
2 . 1 42
'
= + =
= =


Punto A (Compresin Pura):

( )
( )
T N
kg illa cm illas cm cm kg N
f A A A f N
y total acero total acero gruesa c
8 . 739
4200 04 . 8 10 var / 04 . 8 var 10 42 / 281 85 . 0
85 . 0
2 2 2 2
'
=
+ =
+ =


0
100
200
300
400
500
600
700
800
900
1000
0 1 2 3 4
P
n

,

T
u
o
Ductilidad de Curvatura en Funcion de Fuerza Axial
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


60

Punto B (Punto Balanceado):

Ubicar eje neutro:

( )
cm cm c
d d c
E
f
d
c
d
c
c d c
c d c
s
y
y
y
y
13 . 23 2 . 39 59 . 0
59 . 0
003 . 0
10 04 . 2
4200
003 . 0
003 . 0
003 . 0
003 . 0
003 . 0
003 . 0 003 . 0
003 . 0
6
= =
=
|
.
|

\
|
+

=
|
|
.
|

\
|
+
=
+
=
=

=
c
c
c


( )
( )
2 '
2 6 '
'
' '
/ 4200
/ 5379 10 04 . 2
13 . 23
8 . 2 13 . 23
003 . 0
003 . 0
cm kg f f
f cm kg
cm
cm
f
E
c
d c
E f
y s
y s
s s s s
= =
> =

= = c

( ) ( ) ( )
T N
cm kg cm N
f A c b f f A N
T C N
y s c s s
80 . 234
4200 04 . 8 5 13 . 23 85 . 0 50 281 85 . 0 / 4200 04 . 8 5
85 . 0
2 2
1
' ' '
=
+ =
+ =
=
|


Tomando momentos alrededor del centroide plstico, tenemos

( ) ( ) ( )
cm T M
cm T cm T M
M
c h
c b f d
h
f A d
h
f A M
c s s y s
=
+ =
|
.
|

\
|
+ =
|
.
|

\
|
+ |
.
|

\
|
+ |
.
|

\
|
=
349 , 8
203 , 2 146 , 6
2
13 . 23 85 . 0
21 13 . 23 85 . 0 42 281 85 . 0 2 4200 80 . 2 21 04 . 8 5
2 2
85 . 0
2 2
1
1
' ' ' ' '
|
|



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


61

Punto C (Momento Puro):

Variar la ubicacin del eje neutro para satisfacer la condicin de N = 0.


Suponer que
y s
f f <
'


y s
f f =






( )
( )
( ) ( ) ( )
( ) ( )( )
( )
cm c
c
c c
c c c
c
c
c
cm kg cm N
c
d c
E f
f A c b f f A N
T C N
s s
y s c s s
54 . 5
527 , 8 2
867 , 688 527 , 8 4 184 , 77 184 , 77
0 867 , 688 184 , 77 527 , 8
0 840 , 168 527 , 8 867 , 688 024 , 246
0 4200 04 . 8 5 85 . 0 42 281 85 . 0
8 . 2
/ 10 04 . 2 003 . 0 04 . 8 5
003 . 0
85 . 0
2
2
2
2 6 2
'
'
1
' ' '
=
+
=
= +
= +
= +

=
+ =
=
|

( )
( )
2 2 2 6 '
'
'
/ 200 , 4 / 025 , 3
54 . 5
8 . 2 54 . 5
/ 10 04 . 2 003 . 0
003 . 0
cm kg f cm kg cm kg f
c
d c
E f
y s
s s
= < =

=


( ) ( ) ( )
( )
T N
cm T cm T cm T M
cm cm cm kg
cm cm kg cm M
c h
c b f d
h
f A d
h
f A M
c s s y s
0
167 , 6 880 286 , 5
2
54 . 5 85 . 0
21 54 . 5 85 . 0 42 / 281 85 . 0
80 . 2 21 / 025 , 3 4200 04 . 8 5
2 2
85 . 0
2 2
2 2
2 2
1
1
' ' ' ' '
=
= + =
|
.
|

\
|
+
+ =
|
.
|

\
|
+ |
.
|

\
|
+ |
.
|

\
|
=
|
|


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


62

Punto D (Traccin Pura):

T N
cm kg cm N
f A N
y total acero
7 . 337
/ 4200 04 . 8 10
2 2
=
=
=


Resumen de Puntos

Descripcin M
n
, T-cm P
n
, T
compresin pura 0 740
punto balanceado 8,349 235
momento puro 6,167 0
traccin pura 0 -338

Abajo se muestra el correspondiente diagrama de interaccin momento-fuerza axial, usando un solo
grfico para los diagramas para la seccin original y para la seccin confinada.



Se nota que para fuerzas axiales bajas, no hay mucha diferencia entre las curvas, pues el concreto
perdido no influye mucho.

-600
-400
-200
0
200
400
600
800
1000
0 2000 4000 6000 8000 10000 12000
P
n

,

T
M
n
, T-cm
Diagrama de Interaccion Momento-Fuerza Axial,
Combinado
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


63

3.5 Clculo de Diagramas de Interaccin Momento-Fuerza Axial mediante Programas a
Computadora

Se puede usar el programa RECONASANCE para calcular y graficar los mismos diagramas. Al
igual que antes, hay que convertir los datos de entrada en unidades de pulgadas, libras, y kips, y
luego convertir los grficos de salida a unidades mtricas.


Ejemplo:

Usando el programa RECONASANCE, calcular los diagramas de interaccin para la misma seccin
de columna de arriba.



Primero, hay que convertir las unidades:

Cantidad unidades de
kg, cm
unidades de
libras, pulgadas, kips
t 50 cm 19.69 pulg
b 50 cm 19.69 pulg
recubrimiento 4 cm 1.5 pulg
d 43.2 cm 17.01 pulg
d' 6.8 cm 2.68 pulg
s 10 cm 4 pulg
A
s
40.2 cm
2
6.23 pulg
2

A
s
' 40.2 cm
2
6.23 pulg
2

f
y
4200 kg/cm
2
60 kips/pulg
2

f
c
' 281 kg/cm
2
4000 libras/pulg
2

b'' 42 cm 16.54 pulg
p
s

( ) | |
0108 . 0
10 ) 8 50 (
) 8 50 ( 4 2 . 1
4
2
2
=

cm
t

0.0108

Obtenemos los siguientes diagramas, en unidades de kips y pulgadas:
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


64




-798.00
-613.10
-428.20
-243.30
-58.40
126.50
311.40
496.30
681.20
866.10
1051.00
1235.90
1420.80
1605.70
1790.60
0 861 1722 2582 3443 4304 5165 6026 6886 7747 8608
A
x
i
a
l

F
o
r
c
e

(
k
i
p
s
)
Moment (kip-in.)
Moment - Axial Force Interaction Diagram
Unconfined Section, ecmax=0.003 Confined Section, ecmax=0.01 Shear Governed by Vc Shear Governed by Vc+Vs
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


65

En el programa RECONASANCE, vamos a Data for Plots, y obtenemos los siguientes valores:



Initial Section M (kip-in.) N (kips) Confined Section M (kip-in.) N (kips)
0.00 1798.26 0.00 1561.71
2230.15 1794.84 921.82 1561.04
2291.83 1786.59 1070.57 1541.38
2356.71 1777.91 1218.58 1521.68
2437.42 1767.52 1376.02 1500.70
2507.77 1758.07 1547.08 1477.92
2581.17 1748.20 1722.18 1454.47
2657.53 1737.91 1907.12 1429.64
2736.81 1727.19 2100.37 1403.58
2818.92 1716.06 2295.30 1377.09
2903.78 1704.51 2491.28 1350.26
2991.33 1692.55 2688.37 1323.05
3075.05 1680.82 2886.67 1295.47
3168.48 1667.95 3086.25 1267.50
3264.33 1654.68 3287.21 1239.13
3358.53 1641.40 3489.64 1210.35
3456.65 1627.55 3693.64 1181.13
3560.68 1612.91 3899.31 1151.48
3665.34 1598.01 4106.75 1121.37
3773.55 1582.54 4316.08 1090.79
3884.36 1566.60 4527.41 1059.72
3994.33 1550.53 4740.87 1028.14
4103.12 1534.36 4956.57 996.05
4210.75 1518.08 5174.66 963.41
4317.24 1501.71 5395.28 930.21
4422.61 1485.22 5618.56 896.42
4526.89 1468.62 5844.67 862.04
4630.11 1451.91 6073.76 827.03
4732.29 1435.08 6306.00 791.37
4833.46 1418.13 6541.58 755.04
4933.65 1401.05 6780.68 718.01
5032.88 1383.84 6835.02 706.55
5131.21 1366.49 6872.05 697.30
5228.64 1349.00 6907.58 688.05
5325.23 1331.37 6941.62 678.81
5421.01 1313.59 6974.17 669.56
5516.02 1295.65 7005.21 660.31
5610.29 1277.55 7034.77 651.06
5703.88 1259.28 7062.82 641.81
5796.82 1240.84 7089.39 632.57
5889.16 1222.22 7114.45 623.32
5980.96 1203.41 7138.02 614.07
6072.26 1184.41 7160.10 604.82
6163.12 1165.21 7180.68 595.57
6253.59 1145.79 7199.76 586.33
6343.74 1126.16 7217.35 577.08
6433.63 1106.30 7233.44 567.83
6523.33 1086.20 7248.04 558.58
6612.91 1065.86 7261.14 549.33
6702.45 1045.25 7272.75 540.09
6792.02 1024.38 7282.86 530.84
6881.71 1003.23 7291.47 521.59
6971.61 981.79 7298.59 512.34
7061.81 960.04 7304.22 503.09
7152.41 937.97 7308.34 493.85
7243.53 915.57 7310.98 484.60
7335.27 892.82 7312.11 475.35
7427.75 869.69 7311.76 466.10
7521.11 846.19 7309.90 456.85
7615.48 822.27 7306.55 447.61
7711.01 797.94 7301.71 438.36
7807.85 773.15 7302.85 428.07
7906.17 747.90 7324.43 414.71
8006.15 722.15 7345.50 401.22
8107.99 695.88 7366.10 387.59
8211.88 669.05 7386.27 373.80
8318.06 641.65 7406.08 359.86
8426.75 613.63 7425.57 345.76
8538.22 584.96 7444.79 331.48
8557.94 568.83 7463.82 317.02
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


66

Convertimos los valores a unidades de T-cm, y los ponemos en una hoja de clculo para graficar:





Initial Section M (kip-in.) N (kips) Confined Section M (kip-in.) N (kips) Initial Section M (T-cm) N (T) Confined Section M (T-cm) N (T)
0.00 1798.26 0.00 1561.71 0.00 815.61 0.00 708.32
2230.15 1794.84 921.82 1561.04 2569.20 814.06 1061.97 708.02
2291.83 1786.59 1070.57 1541.38 2640.26 810.32 1233.33 699.10
2356.71 1777.91 1218.58 1521.68 2715.01 806.38 1403.85 690.17
2437.42 1767.52 1376.02 1500.70 2807.98 801.67 1585.22 680.65
2507.77 1758.07 1547.08 1477.92 2889.04 797.39 1782.29 670.32
2581.17 1748.20 1722.18 1454.47 2973.59 792.91 1984.01 659.68
2657.53 1737.91 1907.12 1429.64 3061.56 788.24 2197.06 648.42
2736.81 1727.19 2100.37 1403.58 3152.89 783.38 2419.69 636.60
2818.92 1716.06 2295.30 1377.09 3247.48 778.33 2644.26 624.59
2903.78 1704.51 2491.28 1350.26 3345.25 773.09 2870.03 612.42
2991.33 1692.55 2688.37 1323.05 3446.11 767.66 3097.09 600.08
3075.05 1680.82 2886.67 1295.47 3542.55 762.35 3325.53 587.57
3168.48 1667.95 3086.25 1267.50 3650.19 756.51 3555.46 574.88
3264.33 1654.68 3287.21 1239.13 3760.61 750.49 3786.97 562.01
3358.53 1641.40 3489.64 1210.35 3869.14 744.47 4020.18 548.96
3456.65 1627.55 3693.64 1181.13 3982.17 738.18 4255.19 535.71
3560.68 1612.91 3899.31 1151.48 4102.01 731.54 4492.13 522.26
3665.34 1598.01 4106.75 1121.37 4222.59 724.79 4731.11 508.60
3773.55 1582.54 4316.08 1090.79 4347.25 717.77 4972.26 494.73
3884.36 1566.60 4527.41 1059.72 4474.91 710.54 5215.72 480.64
3994.33 1550.53 4740.87 1028.14 4601.60 703.25 5461.63 466.32
4103.12 1534.36 4956.57 996.05 4726.93 695.92 5710.13 451.76
4210.75 1518.08 5174.66 963.41 4850.92 688.54 5961.38 436.96
4317.24 1501.71 5395.28 930.21 4973.60 681.11 6215.53 421.90
4422.61 1485.22 5618.56 896.42 5094.99 673.63 6472.76 406.58
4526.89 1468.62 5844.67 862.04 5215.13 666.10 6733.24 390.98
4630.11 1451.91 6073.76 827.03 5334.03 658.52 6997.16 375.10
4732.29 1435.08 6306.00 791.37 5451.75 650.89 7264.72 358.93
4833.46 1418.13 6541.58 755.04 5568.30 643.20 7536.11 342.45
4933.65 1401.05 6780.68 718.01 5683.72 635.45 7811.56 325.66
5032.88 1383.84 6835.02 706.55 5798.04 627.65 7874.16 320.46
5131.21 1366.49 6872.05 697.30 5911.31 619.78 7916.82 316.27
5228.64 1349.00 6907.58 688.05 6023.56 611.85 7957.76 312.07
5325.23 1331.37 6941.62 678.81 6134.84 603.85 7996.97 307.88
5421.01 1313.59 6974.17 669.56 6245.18 595.79 8034.46 303.68
5516.02 1295.65 7005.21 660.31 6354.63 587.65 8070.23 299.49
5610.29 1277.55 7034.77 651.06 6463.24 579.44 8104.28 295.29
5703.88 1259.28 7062.82 641.81 6571.05 571.16 8136.60 291.10
5796.82 1240.84 7089.39 632.57 6678.12 562.79 8167.20 286.90
5889.16 1222.22 7114.45 623.32 6784.50 554.35 8196.08 282.71
5980.96 1203.41 7138.02 614.07 6890.25 545.81 8223.23 278.52
6072.26 1184.41 7160.10 604.82 6995.43 537.20 8248.66 274.32
6163.12 1165.21 7180.68 595.57 7100.11 528.49 8272.37 270.13
6253.59 1145.79 7199.76 586.33 7204.34 519.68 8294.35 265.93
6343.74 1126.16 7217.35 577.08 7308.19 510.78 8314.62 261.74
6433.63 1106.30 7233.44 567.83 7411.75 501.77 8333.16 257.54
6523.33 1086.20 7248.04 558.58 7515.09 492.65 8349.97 253.35
6612.91 1065.86 7261.14 549.33 7618.29 483.43 8365.07 249.15
6702.45 1045.25 7272.75 540.09 7721.44 474.08 8378.44 244.96
6792.02 1024.38 7282.86 530.84 7824.62 464.62 8390.08 240.76
6881.71 1003.23 7291.47 521.59 7927.95 455.02 8400.01 236.57
6971.61 981.79 7298.59 512.34 8031.51 445.30 8408.21 232.38
7061.81 960.04 7304.22 503.09 8135.43 435.43 8414.69 228.18
7152.41 937.97 7308.34 493.85 8239.81 425.42 8419.45 223.99
7243.53 915.57 7310.98 484.60 8344.78 415.26 8422.48 219.79
7335.27 892.82 7312.11 475.35 8450.47 404.94 8423.79 215.60
7427.75 869.69 7311.76 466.10 8557.01 394.45 8423.38 211.40
7521.11 846.19 7309.90 456.85 8664.56 383.79 8421.24 207.21
7615.48 822.27 7306.55 447.61 8773.28 372.95 8417.38 203.01
-400
-200
0
200
400
600
800
1000
0 2000 4000 6000 8000 10000 12000
F
u
e
r
z
a

A
x
i
a
l
,

T
Momento, T-cm
Diagrama de Interaccion Momento-Fuerza Axial
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


67

Finalmente, graficamos los resultados en unidades de T y cm.

En el grfico, el diagrama externo (azul) corresponde a la seccin inicial y una c
cu
= 0.003, y el
diagrama interno (color caf) corresponde a la seccin confinada y una c
cu
= 0.01. Los dos
diagramas incluyen relaciones realistas esfuerzo-deformacin unitaria para el acero y el concreto.
Finalmente, los dos diagramas incluyen capas superiores en 0.80 P
compresin
. Por estas razones, los
diagramas no corresponden exactamente a los diagramas calculados a mano. Sin embargo, estn
bastante cercanos.


Comentarios

Segn el grfico anterior de M-N y ductilidad de curvatura, es altamente deseable mantener la
columna bajo el punto balanceado. Esto da ms ductilidad de curvatura, y tambin menos prdida de
capacidad al perderse el recubrimiento. La ductilidad tambin se aumenta por confinamiento, igual
que para vigas. Como regla general, se recomienda el uso de una razn volumtrica p
s
~ 0.01.

Para nuestra columna de ejemplo, el espacio mximo entre estribos cerrados para tener p
s
= 0.01 es

( ) | |
cm s
s
cm
s
8 . 10
01 . 0
) 8 50 (
) 8 50 ( 4 2 . 1
4
2
2
=
=

=
t
p


Vamos a usar confinamiento de estribos cerrados de 12 mm en 10 cm.
-400
-200
0
200
400
600
800
1000
0 2000 4000 6000 8000 10000 12000
F
u
e
r
z
a

A
x
i
a
l
,

T
Momento, T-cm
Diagrama de Interaccion Momento-Fuerza Axial
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


68

3.6 Concepto de Diagrama de Interaccin, Gobernado por Corte
A travs de diagramas M-N, podemos disear una seccin para tener suficiente resistencia en
flexin. Tambin, podemos proveerle suficiente capacidad de deformacin inelstica, expresada en
trminos de ductilidad de curvatura. Usando confinamiento con espacio de unos 10 cm, podemos
evitar o demorar el pandeo de las varillas longitudinales.

Pero tambin tenemos que proporcionar a la columna resistencia cortante suficiente para evitar ese
tipo de falla frgil. Tenemos que contestar dos preguntas:
,
1) Cul es el corte mximo que puede experimentar una columna?

2) Cmo puede la columna resistirlo?

La primera pregunta se contesta usando el dibujo de abajo. El corte mximo es el que corresponde a
la formacin de rtulas plsticas en los dos extremos de la columna:



Igual que antes, M
ult
debe calcularse usando el f
y
probable, con un margen por sobre-resistencia del
acero y endurecimiento por deformacin. Este corte se resiste por

s c n
V V V + =

En el ACI 318, V
c
corresponde al corte necesario para formar una grieta inclinada, y se expresa en
trminos de la resistencia del concreto en traccin diagonal. Luego de formarse grietas diagonales,
Vc se debe principalmente a una combinacin de friccin por el bloque compresivo, engranaje a lo
largo de la grieta diagonal, y accin de dovela del refuerzo longitudinal. El ACI 318 supone que
despus del agrietamiento, la resistencia cortante es no menor que Vc .

Vs se debe a esfuerzos de traccin en los estribos que atraviesan grietas supuestamente inclinadas a
45. Al principio , la resistencia disponible de l a columna ser igual a Vc + Vs . Pero con la
degradacin de la columna bajo cargas cclicas, la resistencia se acerca a Vs . Entonces, la
resistencia a corte depende de dos factores:

1) Cul es la resistencia de la columna, a la formacin de grietas inclinadas?

Esta resistencia es Vc . Si Vc excede el mximo corte aplicado, no habr degradacin por corte.
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


69

2) Cul es la resistencia degradada de la columna?

Esta resistencia se aproxima por Vs . Si Vs excede el mximo corte aplicable, la seccin puede
resistir el corte, an despus de la forrnaci6n de grietas inclinadas.

Comparando estos niveles de resistencia con el mximo corte aplicado (una funcin de la capacidad
en flexin) podemos determinar si o no el comportamiento de la columna ser gobernado por corte.
En unidades de kg y cm,

d b
d h
N M
d V
f V
w
u u
u
w c c

|
.
|

\
|

+ =
8
4
176 5 . 0
'
p


ACI 318-08, Ecuacin 11-5

pero

g
u
w c c
A
N
d b f V 029 . 0 1 93 . 0
'
+ s

ACI 318-08, Ecuacin 11-7

y

s
d
f A V
y v s
=


Dada la fuerza axial N, conocemos la capacidad flectora M
n
a travs del diagrama M-N, y podemos
calcular el mximo corte posible.

Para cualquier combinacin de M y N, podemos calcular las resistencias claves Vc y Vs, usando las
ecuaciones del ACI 318. Estas resistencias pueden graficarse en el diagrama de interaccin, en
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


70
trminos de los momentos necesarios para producir el corte correspondiente. El resultado es un
diagrama M-N controlado por corte.


Ejemplo:

Usando la seccin de arriba, calcular un diagrama M-N, controlado por corte.



M(V
c
) (momento gobernado por V
c
) = V
c
L / 2 = M
c


n
n
c
c
u
u
w
u u
u
w c c
V
M
V
M
V
M
d b
d h
N M
d V
f V
= =

|
.
|

\
|

+ =
8
4
176 5 . 0
'
p


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


71
( )
0
8
4
5 . 0
2
176
8
4 2
5 . 0
2
2
176
8
4
5 . 0
8
4 2
8
4
2
176 5 . 0
2
'
2
'
2
2 '
'
= |
.
|

\
|
+

|
|
.
|

\
|
+

+
|
.
|

\
|
+

|
.
|

\
|
=

|
.
|

\
|

|
.
|

\
|

|
.
|

\
|
+ =
d b
d h
N f
M
L
d b
L
d h N
d b f
L
M
d b
L
M
d b
d h
N M f
d h
N M
L
M
d b
d h
N M
d
L
M
f
L
M
w c c
c
w
w
c
w c
c
w
c
w w c c c c c
c
w
c c
c
w c
c
p
p
p


Ahora, para cualquier N
c
, se puede calcular el momento M
c
que produce un corte igual a V
c
.

Nuestra columna tiene las caractersticas siguientes:

Cantidad unidades de
kg, cm
t = h 50 cm
b - b
w
50 cm
L 300 cm
recubrimiento 4 cm
d 43.2 cm
d' 6.8 cm
s 10 cm
A
s
40.2 cm
2

A
s
' 40.2 cm
2

f
y
4200 kg/cm
2

f
c
' 281 kg/cm
2

b'' 42 cm
p
w

019 . 0
2 . 43 50
04 . 8 5
2
2
=

=
cm
cm
d b
A
w
s

p
s

( ) | |
0135 . 0
10 ) 8 50 (
) 8 50 ( 5 2 . 1
4
2
2
=

cm
t



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


72

N
c
= 0:

Probar la Ecuacin 11-5:

( )
cm T cm kg cm kg M
M
cm
cm cm
cm cm cm kg
L
M
M
L
d b
d b f
L
M
d b
d h
N f
M
L
d b
L
d h N
d b f
L
M
c
c
c
c
w
w w c
c
w c c
c
w
w
c
w c
c
= = =
=

|
|
.
|

\
|
+
=

|
|
.
|

\
|
+
= |
.
|

\
|
+

|
|
.
|

\
|
+

+
028 , 3 10 028 . 3 20184 150
0
300
2 . 43 50 2
019 . 0 176 2 . 43 50 / 281 5 . 0
2
0
2
176 5 . 0
2
0
8
4
5 . 0
2
176
8
4 2
5 . 0
2
6
2 2
2
2
2
'
2
'
2
'
2
p
p



Verificar la Ecuacin 11-7:

gobierna no cm T
cm kg L V
M
kg V
A
N
d b f V
c
c
c
g
u
w c c
=

= =
= + s
+ s
5051
2
300 674 , 33
2
674 , 33 0 1 2 . 43 50 281 93 . 0
029 . 0 1 93 . 0
'



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


73

N
c
= 250 T:

Probar la Ecuacin 11-5:

( )
( )
cm T cm kg M
M
M
M
cm
cm cm
cm cm cm kg
L
M
d b
d h
N f
M
L
d b
L
d h N
d b f
L
M
c
c
c
c
c
w c c
c
w
w
c
w c
c
= =
|
.
|

\
|

+
=
= +
= |
.
|

\
|
+

|
|
.
|

\
|
+

= |
.
|

\
|
+

|
|
.
|

\
|
+

+
5515 000 , 515 , 5
150
2
150
10 87 . 8 4
52851 52851
0 10 87 . 8 52851
150
0 2 . 43 50
8
2 . 43 50 4
10 250 281 5 . 0
300
2 . 43 50 2
019 . 0 176
300 8
2 . 43 50 4 10 250 2
2 . 43 50 / 281 5 . 0
2
0
8
4
5 . 0
2
176
8
4 2
5 . 0
2
10
2
10
2
3
2 2
3
2
2
'
2
'
2
p



Verificar la Ecuacin 11-7:

gobierna no cm T
cm kg L V
M
kg V
A
N
d b f V
c
c
c
g
u
w c c
=

= =
=

+ s
+ s
9975
2
300 500 , 66
2
500 , 66
50
10 250
029 . 0 1 2 . 43 50 281 93 . 0
029 . 0 1 93 . 0
2
3
'


Finalmente, verificar

( )
( )
bien M
d h
N M M
m
u c m
0 615
8
2 . 43 50 4
250 5515
0
8
4
> =

=
>

=



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


74
N
c
= 500 T:

Probar la Ecuacin 11-5:

( )
( )
cm T M
M
M
M
cm
cm cm
cm cm cm kg
L
M
d b
d h
N f
M
L
d b
L
d h N
d b f
L
M
c
c
c
c
c
w c c
c
w
w
c
w c
c
=
|
.
|

\
|

+
=
= +
= |
.
|

\
|
+

|
|
.
|

\
|
+

= |
.
|

\
|
+

|
|
.
|

\
|
+

+
10233
150
2
150
10 77 . 1 4
85517 85517
0 10 77 . 1 85517
150
0 2 . 43 50
8
2 . 43 50 4
10 500 281 5 . 0
300
2 . 43 50 2
019 . 0 176
300 8
2 . 43 50 4 10 500 2
2 . 43 50 / 281 5 . 0
2
0
8
4
5 . 0
2
176
8
4 2
5 . 0
2
11
2
11
2
3
2 2
3
2
2
'
2
'
2
p



Verificar la Ecuacin 11-7:

gobierna no cm T
cm kg L V
M
kg V
A
N
d b f V
c
c
c
g
u
w c c
=

= =
=

+ s
+ s
13172
2
300 87810
2
87810
50
10 500
029 . 0 1 2 . 43 50 281 93 . 0
029 . 0 1 93 . 0
2
3
'


Finalmente, verificar

( )
( )
bien M
d h
N M M
m
u c m
0 433
8
2 . 43 50 4
500 10233
0
8
4
> =

=
>

=


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


75
Ahora debemos examinar la resistencia cortante debido a V
s
. Es independiente de N.

( )
cm T
cm kg L V
M
kg cm kg cm V
s
d
f A V
s
s
s
y v s
=

= =
= |
.
|

\
|
=
=
9234
2
300 61562
2
562 , 61
10
2 . 43
/ 4200 2 . 1
4
3
2 2
t


Resumen de Puntos, M(V
c
) verso P
n


M(V
c
), T-cm P
n
, T
3,028 0
5,515 250
10,233 500

La curva de M-N controlada por corte est graficada abajo, junta con los diagramas de M-N
controlados por flexin que derivamos anteriormente:


Es de notarse que para N < N
balanceado
, la columna se va a agrietar por corte antes de ceder por
flexin.
-600
-400
-200
0
200
400
600
800
1000
0 2000 4000 6000 8000 10000 12000
P
n

,

T
M
n
, T-cm
Diagrama de Interaccion Momento-Fuerza Axial,
Combinado, y Controlado por Corte
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


76

Inmediatamente despus de la formacin de grietas inclinadas, la capacidad cortante de la columna
es por lo menos V
c
+ V
s
, suficiente para resistir el corte consistente con el desarrollo de rtulas
plsticas en los extremos de la columna. Eventualmente, la resistencia puede degradarse a slo V
s
.
Un espacio de 10 cm proporciona un V
s
suficiente para resistir los cortes mximos posibles en una
columna sin recubrimiento, pero no en el estado original. Esta columna tiene un chance ligero de
fallar eventualmente por corte.


3.7 Clculo de Diagramas de Interaccin Momento-Fuerza Axial (incluyendo Efectos de
Corte) mediante Programas a Computadora

Dichosamente, el programa RECONASANCE tambin calcula diagramas de interaccin, gobernados
por corte. Al igual que antes, hay que convertir las unidades:

Nuestra columna tiene las caractersticas siguientes:

Cantidad unidades de
kg, cm
unidades de
libras, pulgadas, kips
t = h 50 cm 19.69 pulg
b - b
w
50 cm 19.69 pulg
L 300 cm 118 pulg
recubrimiento 4 cm 1.5 pulg
d 43.2 cm 17.01 pulg
d' 6.8 cm 2.68 pulg
s 10 cm 4 pulg
A
s
40.2 cm
2
6.23 pulg
2

A
s
' 40.2 cm
2
6.23 pulg
2

f
y
4200 kg/cm
2
60 kips/pulg
2

f
c
' 281 kg/cm
2
4000 libras/pulg
2

b'' 42 cm 16.54 pulg
p
w

019 . 0
2 . 43 50
04 . 8 5
2
2
=

=
cm
cm
d b
A
w
s
0.019
p
s

( ) | |
0135 . 0
10 ) 8 50 (
) 8 50 ( 5 2 . 1
4
2
2
=

cm
t

0.0135


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


77

Obtenemos los siguientes diagramas, en unidades de kips y pulgadas:



-1091.00
-906.10
-721.20
-536.30
-351.40
-166.50
18.40
203.30
388.20
573.10
758.00
942.90
1127.80
1312.70
1497.60
1682.50
0 2311 4621 6932 9242 11553 13863 16174 18484 20795 23105
A
x
i
a
l

F
o
r
c
e

(
k
i
p
s
)
Moment (kip-in.)
Moment - Axial Force Interaction Diagram
Unconfined Section, ecmax=0.003 Confined Section, ecmax=0.01 Shear Governed by Vc Shear Governed by Vc+Vs
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


78
En el programa RECONASANCE, vamos a Data for Plots, y obtenemos los siguientes valores:




c cmax c (in.) M (kip-in.) o x 10
3
(rad/in. )
Initial Section M (kip-in.) N (kips) Confined Section M (kip-in.) N (kips) Governed by Vc+Vs M (kip-in.) N (kips) Govern
0.00 0.00 0.00 0.0000 0.00 1798.26 0.00 1604.33 23054.83 1798.26
0.0005 6.11 2373.81 0.0818 2230.15 1794.84 847.27 1599.00 23045.86 1795.72
0.001 6.27 4532.38 0.1594 2291.83 1786.59 989.80 1580.05 23036.89 1793.17
0.002 4.41 5594.01 0.4530 2356.71 1777.91 1138.74 1560.21 23027.92 1790.62
0.0025 3.99 5603.27 0.6269 2437.42 1767.52 1286.93 1540.33 23018.94 1788.08
0.003 3.80 5645.10 0.7893 2507.77 1758.07 1444.52 1519.17 23009.95 1785.53
0.0035 3.77 5860.50 0.9285 2581.17 1748.20 1615.73 1496.21 23000.96 1782.99
0.004 3.76 6052.69 1.0637 2657.53 1737.91 1790.96 1472.58 22991.96 1780.44
Moment-curvature data points for initial section 2736.81 1727.19 1976.01 1447.57 22982.96 1777.89
2818.92 1716.06 2169.35 1421.33 22973.95 1775.35
2903.78 1704.51 2364.37 1394.67 22964.94 1772.80
c cmax c (in.) M (kip-in.) o x 10
3
(rad/in. )
2991.33 1692.55 2560.41 1367.65 22955.91 1770.26
0.00 0.00 0.00 0.0000 3075.05 1680.82 2757.55 1340.27 22946.89 1767.71
0.0005 5.62 2191.97 0.0890 3168.48 1667.95 2955.88 1312.51 22937.86 1765.16
0.001 5.75 4218.72 0.1740 3264.33 1654.68 3155.49 1284.36 22928.82 1762.62
0.002 3.15 5345.62 0.6345 3358.53 1641.40 3356.45 1255.81 22919.77 1760.07
0.0025 2.66 5630.55 0.9418 3456.65 1627.55 3558.87 1226.85 22910.72 1757.53
0.003 2.46 6095.43 1.2202 3560.68 1612.91 3762.84 1197.46 22901.67 1754.98
0.0035 2.32 6529.80 1.5083 3665.34 1598.01 3968.46 1167.63 22885.52 1752.44
0.0040 2.21 6933.46 1.8063 3773.55 1582.54 4175.84 1137.34 22865.96 1749.89
0.0045 2.25 7153.94 2.0034 3884.36 1566.60 4385.09 1106.58 22846.41 1747.34
0.0050 2.36 7256.58 2.1215 3994.33 1550.53 4596.33 1075.33 22826.85 1744.80
0.0060 2.56 7432.12 2.3445 4103.12 1534.36 4809.68 1043.58 22807.30 1742.25
0.0070 2.74 7577.07 2.5548 4210.75 1518.08 5025.26 1011.30 22787.74 1739.71
0.0080 2.91 7698.50 2.7536 4317.24 1501.71 5243.21 978.48 22768.19 1737.16
0.0090 3.06 7801.38 2.9429 4422.61 1485.22 5463.67 945.10 22748.64 1734.61
0.0100 3.20 7889.17 3.1247 4526.89 1468.62 5686.78 911.14 22729.08 1732.07
0.0200 3.85 8578.85 5.1933 4630.11 1451.91 5912.70 876.58 22709.53 1729.52
0.0300 3.57 8780.13 8.3986 4732.29 1435.08 6141.59 841.39 22689.98 1726.98
0.0400 3.26 8816.30 12.2925 4833.46 1418.13 6373.62 805.55 22670.43 1724.43
0.0500 2.95 8849.60 16.9695 4933.65 1401.05 6608.96 769.04 22650.87 1721.89
Moment-curvature data points for confined section 5032.88 1383.84 6847.81 731.83 22631.32 1719.34
5131.21 1366.49 6901.88 720.20 22611.77 1716.79
5228.64 1349.00 6938.63 710.77 22592.22 1714.25
5325.23 1331.37 6973.87 701.34 22572.67 1711.70
5421.01 1313.59 7007.60 691.92 22553.12 1709.16
5516.02 1295.65 7039.81 682.49 22533.57 1706.61
5610.29 1277.55 7070.52 673.06 22514.02 1704.06
5703.88 1259.28 7099.71 663.64 22494.47 1701.52
5796.82 1240.84 7127.39 654.21 22474.92 1698.97
5889.16 1222.22 7153.56 644.78 22455.38 1696.43
5980.96 1203.41 7178.22 635.36 22435.83 1693.88
6072.26 1184.41 7201.37 625.93 22416.28 1691.33
6163.12 1165.21 7223.00 616.50 22396.73 1688.79
6253.59 1145.79 7243.13 607.08 22377.19 1686.24
6343.74 1126.16 7261.74 597.65 22357.64 1683.70
6433.63 1106.30 7278.84 588.22 22338.10 1681.15
6523.33 1086.20 7294.43 578.80 22318.55 1678.61
6612.91 1065.86 7308.51 569.37 22299.00 1676.06
6702.45 1045.25 7321.08 559.94 22279.46 1673.51
6792.02 1024.38 7332.14 550.52 22259.92 1670.97
6881.71 1003.23 7341.68 541.09 22240.37 1668.42
6971.61 981.79 7349.72 531.66 22220.83 1665.88
7061.81 960.04 7356.24 522.24 22201.28 1663.33
7152.41 937.97 7361.25 512.81 22181.74 1660.78
7243.53 915.57 7364.75 503.38 22162.20 1658.24
7335.27 892.82 7366.74 493.96 22142.66 1655.69
7427.75 869.69 7367.22 484.53 22123.12 1653.15
7521.11 846.19 7366.19 475.10 22103.57 1650.60
7615.48 822.27 7363.64 465.68 22084.03 1648.06
7711.01 797.94 7359.59 456.25 22064.49 1645.51
7807.85 773.15 7354.02 446.82 22044.95 1642.96
7906.17 747.90 7354.42 436.35 22025.41 1640.42
8006.15 722.15 7375.25 422.82 22005.87 1637.87
8107.99 695.88 7395.55 409.15 21986.33 1635.33
8211.88 669.05 7415.36 395.34 21966.80 1632.78
8318.06 641.65 7434.74 381.38 21947.26 1630.23
8426.75 613.63 7453.73 367.26 21927.72 1627.69
8538.22 584.96 7472.38 352.97 21908.18 1625.14
8557.94 568.83 7490.76 338.52 21888.65 1622.60
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


79

Convertimos los valores a unidades de T-cm, y los ponemos en una hoja de clculo para graficar:







c cmax c (in.) M (kip-in.) o x 10
3
(rad/in. )
Initial Section M (kip-in.) N (kips) Confined Section M (kip-in.) N (kips) Governed by Vc+Vs M (kip-in.) N (kips) Governed by Vc M (kip-in.)
0.00 0.00 0.00 0.0000 0.00 1798.26 0.00 1604.33 23054.83 1798.26 14022.52
0.0005 6.11 2373.81 0.0818 2230.15 1794.84 847.27 1599.00 23045.86 1795.72 14013.55
0.001 6.27 4532.38 0.1594 2291.83 1786.59 989.80 1580.05 23036.89 1793.17 14004.58
0.002 4.41 5594.01 0.4530 2356.71 1777.91 1138.74 1560.21 23027.92 1790.62 13995.61
0.0025 3.99 5603.27 0.6269 2437.42 1767.52 1286.93 1540.33 23018.94 1788.08 13986.63
0.003 3.80 5645.10 0.7893 2507.77 1758.07 1444.52 1519.17 23009.95 1785.53 13977.64
0.0035 3.77 5860.50 0.9285 2581.17 1748.20 1615.73 1496.21 23000.96 1782.99 13968.65
0.004 3.76 6052.69 1.0637 2657.53 1737.91 1790.96 1472.58 22991.96 1780.44 13959.65
Moment-curvature data points for initial section 2736.81 1727.19 1976.01 1447.57 22982.96 1777.89 13950.65
2818.92 1716.06 2169.35 1421.33 22973.95 1775.35 13941.64
2903.78 1704.51 2364.37 1394.67 22964.94 1772.80 13932.63
c cmax c (in.) M (kip-in.) o x 10
3
(rad/in. )
2991.33 1692.55 2560.41 1367.65 22955.91 1770.26 13923.60
0.00 0.00 0.00 0.0000 3075.05 1680.82 2757.55 1340.27 22946.89 1767.71 13914.58
0.0005 5.62 2191.97 0.0890 3168.48 1667.95 2955.88 1312.51 22937.86 1765.16 13905.55
0.001 5.75 4218.72 0.1740 3264.33 1654.68 3155.49 1284.36 22928.82 1762.62 13896.51
0.002 3.15 5345.62 0.6345 3358.53 1641.40 3356.45 1255.81 22919.77 1760.07 13887.46
0.0025 2.66 5630.55 0.9418 3456.65 1627.55 3558.87 1226.85 22910.72 1757.53 13878.41
0.003 2.46 6095.43 1.2202 3560.68 1612.91 3762.84 1197.46 22901.67 1754.98 13869.36
0.0035 2.32 6529.80 1.5083 3665.34 1598.01 3968.46 1167.63 22885.52 1752.44 13853.21
0.0040 2.21 6933.46 1.8063 3773.55 1582.54 4175.84 1137.34 22865.96 1749.89 13833.65
0.0045 2.25 7153.94 2.0034 3884.36 1566.60 4385.09 1106.58 22846.41 1747.34 13814.10
0.0050 2.36 7256.58 2.1215 3994.33 1550.53 4596.33 1075.33 22826.85 1744.80 13794.54
0.0060 2.56 7432.12 2.3445 4103.12 1534.36 4809.68 1043.58 22807.30 1742.25 13774.99
0.0070 2.74 7577.07 2.5548 4210.75 1518.08 5025.26 1011.30 22787.74 1739.71 13755.43
0.0080 2.91 7698.50 2.7536 4317.24 1501.71 5243.21 978.48 22768.19 1737.16 13735.88
0.0090 3.06 7801.38 2.9429 4422.61 1485.22 5463.67 945.10 22748.64 1734.61 13716.33
0.0100 3.20 7889.17 3.1247 4526.89 1468.62 5686.78 911.14 22729.08 1732.07 13696.77
0.0200 3.85 8578.85 5.1933 4630.11 1451.91 5912.70 876.58 22709.53 1729.52 13677.22
0.0300 3.57 8780.13 8.3986 4732.29 1435.08 6141.59 841.39 22689.98 1726.98 13657.67
0.0400 3.26 8816.30 12.2925 4833.46 1418.13 6373.62 805.55 22670.43 1724.43 13638.12
0.0500 2.95 8849.60 16.9695 4933.65 1401.05 6608.96 769.04 22650.87 1721.89 13618.56
Moment-curvature data points for confined section 5032.88 1383.84 6847.81 731.83 22631.32 1719.34 13599.01
5131.21 1366.49 6901.88 720.20 22611.77 1716.79 13579.46
5228.64 1349.00 6938.63 710.77 22592.22 1714.25 13559.91
5325.23 1331.37 6973.87 701.34 22572.67 1711.70 13540.36
5421.01 1313.59 7007.60 691.92 22553.12 1709.16 13520.81
5516.02 1295.65 7039.81 682.49 22533.57 1706.61 13501.26
5610.29 1277.55 7070.52 673.06 22514.02 1704.06 13481.71
5703.88 1259.28 7099.71 663.64 22494.47 1701.52 13462.16
5796.82 1240.84 7127.39 654.21 22474.92 1698.97 13442.61
5889.16 1222.22 7153.56 644.78 22455.38 1696.43 13423.07
5980.96 1203.41 7178.22 635.36 22435.83 1693.88 13403.52
6072.26 1184.41 7201.37 625.93 22416.28 1691.33 13383.97
6163.12 1165.21 7223.00 616.50 22396.73 1688.79 13364.42
6253.59 1145.79 7243.13 607.08 22377.19 1686.24 13344.88
6343.74 1126.16 7261.74 597.65 22357.64 1683.70 13325.33
6433.63 1106.30 7278.84 588.22 22338.10 1681.15 13305.79
6523.33 1086.20 7294.43 578.80 22318.55 1678.61 13286.24
6612.91 1065.86 7308.51 569.37 22299.00 1676.06 13266.69
6702.45 1045.25 7321.08 559.94 22279.46 1673.51 13247.15
6792.02 1024.38 7332.14 550.52 22259.92 1670.97 13227.61
6881.71 1003.23 7341.68 541.09 22240.37 1668.42 13208.06
6971.61 981.79 7349.72 531.66 22220.83 1665.88 13188.52
7061.81 960.04 7356.24 522.24 22201.28 1663.33 13168.97
7152.41 937.97 7361.25 512.81 22181.74 1660.78 13149.43
7243.53 915.57 7364.75 503.38 22162.20 1658.24 13129.89
7335.27 892.82 7366.74 493.96 22142.66 1655.69 13110.35
7427.75 869.69 7367.22 484.53 22123.12 1653.15 13090.81
7521.11 846.19 7366.19 475.10 22103.57 1650.60 13071.26
7615.48 822.27 7363.64 465.68 22084.03 1648.06 13051.72
-600
-400
-200
0
200
400
600
800
1000
0 5000 10000 15000 20000 25000 30000
F
u
e
r
z
a

A
x
i
a
l
,

T
Momento, T-cm
Diagrama de Interaccion Momento-Fuerza Axial, incluyendo
Corte
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


80

Finalmente, graficamos los resultados en unidades de T y cm.



Se nota que los resultados estn bastante cercanos a los previamente obtenidos por clculos a mano.


3.8 Observaciones sobre el Comportamiento de Regiones Criticas de Columnas de Concreto
Reforzado

3.8.1 Papel de V
s


1) Para fuerzas axiales menores que unos 400 T, la columna se agrieta en corte antes de ceder
en flexin. Pero esto no necesariamente quiere decir que la columna falle por corte antes de
llegar a su capacidad en flexin. Cuando se agrega la capacidad provieniente de Vs, la
resistencia total cortante es mayor que la resistencia en flexin. Con ciclos alternos, es
posible que la resistencia cortante degrada a solamente Vs (es decir, V de puntales y
tensores).


3.8.2 Efectos de Fuerza Axial


2) Fuerzas axiales en traccin efectivamente eliminan la resistencia cortante. A medida que las
fuerzas axiales compresivas se aumenten, se aumenta la resistencia cortante tambin. Con
-600
-400
-200
0
200
400
600
800
1000
0 5000 10000 15000 20000 25000 30000
F
u
e
r
z
a

A
x
i
a
l
,

T
Momento, T-cm
Diagrama de Interaccion Momento-Fuerza Axial, incluyendo
Corte
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


81
fuerzas axiales pequeas (unas 0.1 Vo), la columna tiene ductilidad razonable en flexin y
bastante resistencia cortante.

3) Fuerzas axiales mayores aumentan la resistencia cortante ms an, pero a costo de una
disminucin inaceptable de ductilidad en flexin.

4) Fuerzas axiales mayores que la fuerza balanceada resultan en ductilidad inaceptable en
flexin.


3.8.3 Efectos de Carga Cclica Alterna

5) Cargas cclicas alternas abren grietas por flexin por el peralte entero de la seccin,
reduciendo la rigidez en flexin. Este proceso se demora ligeramente por fuerzas axiales
compresivas.

6) El corte tiende a provocar deslizamiento por estas grietas por flexin, dando lugar a una falla
por corte deslizante. Este tipo de falla puede demorarse mediante refuerzo transversal en
pequeo espacio.


3.8.4 Resumen de Mecanismos de Resistencia de Columnas de Concreto Reforzado

Estado de Dao Vc Vs

No Agrietado

d b
d h
N M
d V
f V
w
u u
u
w c c

|
.
|

\
|

+ =
8
4
176 5 . 0
'
p

(Ecuacin emprica con base en esfuerzo mximo
principal. Ver seccin sobre muros cortantes.)

no efectivo

Luego de
Agrietamiento
Inclinado

V
c
no menor que la ecuacin de arriba. Resistencia real
del concreto se debe en mayor parte a friccin por el
bloque compresivo.


s
d
f A V
y v s
=

Durante Cclica
Alterna


V
c
tiende a 0

Vs es inicialmente
igual a la ecuacin
de arribe, pero se
degrada a la medida
que se formen grietas
travesaas por
flexin.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


82



3.9 Principios Bsicos del Diseo de Regiones Crticas de Columnas de Concreto Reforzado

De lo anterior, podemos concluir lo siguiente:

1) Amplia ductilidad de curvatura puede obtenerse con fuerzas axiales muy debajo de la fuerza
balanceada.

2) Despus de la prdida del recubrimiento, buen mantenimiento de la capacidad en flexin
puede obtenerse usando estribos cercanamente espaciados.

3) La resistencia al agrietamiento inclinado puede estimarse comparando el diagrama de
interaccin M-N, con la curva de momento controlado por Vc. Si la curva de momento
controlado por Vc cae fuera del diagrama M-N, la columna no experimenta agrietamiento
significativo.

4) La resistencia a degradacin cortante despus de la formacin de grietas inclinadas puede
estimarse comparando el diagrama de interaccin M-N, con la curva de momento controlado
por Vs. Si la curva de M controlado por Vs cae fuera del diagrama M-N, la columna se
degrada lentamente por corte.

5) Cargas cclicas alternas aceleran el proceso de degradacin cortante.


Sin embargo , estas observaciones son un poco complejas para usarse en forma rutina en el diseo.
Pueden simplificarse en trminos de parmetros esenciales de diseo.

1) carga axial
2) refuerzo transversal
3) razn de luz de corte


Carga Axial

Podemos estimar el punto balanceado (sin factores o) mediante

3
0
N
N
balanceada
~






Refuerzo Transversal

De nuestro ejemplo, hemos visto que hasta estribos de 12 mm en 20 cm no pueden proporcionar
buen comportamiento momento-curvatura en niveles tpicos de carga axial. Esto corresponde a una
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


83
razn volumtrica de p
s
= 0.008. Para ductilidad de curvatura y confinamiento satisfactorio,
debemos tener p
s
> 0.01. Para apoyo satisfactorio del acero longitudinal, debemos tener s < 4 d
b
.
Entonces, un mnimo prctico para refuerzo transversal es 12 mm en 10 cm para secciones tpicas de
columna.


Razn de Luz de Corte

La razn de luz de corte se define como



Vd
M
d
a
Razon =


Aunque Vc es una funcin compleja de M y N, en trminos
generales,

balanciada w c c
g w c c
N d b f V
tipico y N d b f V
'
'
9 . 01
0 8 . 0
~
= ~ p


Para valores tpicos de carga axial y momento flector,

d b f a V
w c c
'
6 . 1 3 . 1 ~

Consideremos los diagramas de interaccin para una columna tpica:


En unidades de kips y pulgadas,

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


84
g
g
balanceada
t A
M
M M
p
o
10 4 . 0
max
max
+ ~
=


Por ejemplo, para p
g
= 0.01, 5 . 0
max
~
t A
M
g
o
.

Entonces, en unidades de libras y pulgadas,

( )
t A M
g
g
o
p 10 4 . 0 1000
max
+
~

Vd
M
d
a
Razon =

( )
|
.
|

\
|
+
~ |
.
|

\
|
Vd
t A
d
a
g
g 1
10 4 . 0 1000
o
p
(Relacin entre M
mx
y V
requerido
en funcin de (a/d))

Expresar V
requerido
en funcin de
'
c
f .

d b f k d b f k V
c w c requerido
' '
= =

( )
d d b f k
t A
d
a
c
g g

+
~
|
.
|

\
|
'
10 4 . 0 1000
o
p


Para = 0.75,
( )
88 . 0
2
1
=
+
=
|
.
|

\
|
t
d
.

( ) ( )
( )
2 '
88 . 0
10 4 . 0 1000
t t b f k
t bt
d
a
c
g

+
~
|
.
|

\
|
o
p


( )( )
( )
( )
( )
|
.
|

\
|
+
~
|
.
|

\
|

+
~
d
a
f
k
d
a
t t b f
t bt
k
c
g
requerida
c
g
requerida
2 '
2 '
88 . 0
10 4 . 0 1000
88 . 0
10 4 . 0 1000
o
p
o
p


Para f
c
' = 6000 libras/pulg
2
(420 kg/cm
2
) y o = 0.70,
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


85

( )
( )
( )
|
.
|

\
|
+
~
|
.
|

\
|
+
~
d
a
k
d
a
k
g
requerida
g
requerida
p
p
10 4 . 0 82 . 23
88 . 0 6000 70 . 0
10 4 . 0 1000
2


En unidades de kg y cm,


( )
|
.
|

\
|
+
~
d
a
k
g
requerida
p 10 4 . 0 82 . 23


( )
d b f
V
d
a
k
w c
requerido g
requerida
'
10 4 . 0 32 . 6
=
|
.
|

\
|
+
~
p


(capacidad cortante en funcin de la capacidad en flexin y la razn de luz de corte)



Observaciones:

1) Para valores razonables de pg (1-3%), razones de luz de corte menores que unos 2.0
producen cortes mayores que el mximo Vc disponible.
0.0
1.0
2.0
3.0
4.0
5.0
0 1 2 3 4 5 6 7
k
r
e
q
u
e
r
i
d
a
(a/d)
k
requerida
verso (a/d)
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


86

2) Razones de luz de corte menores que 2 producen agrietamiento diagonal temprano, y la
posibilidad de degradacin rpida por corte.

3) Una razn de luz de corte de 2 corresponde a una razn de L/h de unos 3.5:



5 . 3 2
88 . 0 2 2
= =

= =
h
L
h
L
d
L
d
a



Ahora se puede caracterizar el comportamiento de columnas en
trminos de una razn de fuerza axial y el aspecto (L/h):



|
.
|

\
|
h
L

> 3.5 < 3.5


g c
A f
N
'



< 1/3

Buen comportamiento en
flexin y disipacin de
energa

Se forman grietas
inclinadas; la columna se
degrada lentamente en
corte, dependiendo de ps.
Ductilidad limitada.


> 1/3

Comportamiento
gobernado por flexin,
pero ductilidad limitada.


Falla rpida por corte.
Ductilidad despreciable.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


87

3.10 Columnas Potencialmente Peligrosas
En vista de las guas de arriba, unos tipos de columna pueden identificarse como potencialmente
peligrosas:


1) Columnas con razones (L/h) muy pequeas:




2) Columnas en traccin:

Vigas de corta luz en el vano izquierdo transfieren cortes
significativos a la columna izquierda, posiblemente provocando
traccin all bajo cargas laterales.

La columna tendr resistencia despreciable al agrietamiento
inclinado, y se va a degradar rpidamente en corte deslizante.







3) Pisos blandos:


Las columnas estarn sujetas a fuerzas axiales muy grandes, y a
lo mejor no sern capaces de desarrollar la ductilidad necesaria.



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


88

3.11 El Diseo Instantneo de Columnas de Concreto Reforzado
Los fundamentos del comportamiento de
columnas de concreto reforzado expresados en
esta seccin, pueden encapsularse en unos
procedimientos generales de diseo de tales
columnas:

Usar las mismas cargas de antes, con un rea
tributaria de 36 m
2
.

Carga muerta:

losa de 20 cm 500 kg/m
2

divisorios 100 kg/m
2

total 600 kg/m
2


Carga viva:

250 kg/m
2
, reducida por rea tributaria
(mltiples pisos)
100 kg/m
2



( ) ( )
2 2 2 2
/ 88 . 0 / 880 / 100 6 . 1 / 600 2 . 1 m T m kg m kg m kg q
u
~ = + =

Para contar el peso propio de las columnas, usar 1.0 T/m
2
.

( ) ) ( 36 6 / 0 . 1
2 2
T n n m m T P
u
= =

Disear la columna para estar bajo el punto balanceado, con refuerzo del 2% y f
c
' de 420 kg/cm
2
.

3
0
P
P y
P
P
P P
n
u
n
n u
~ >
s
o
o


o
u
P
P
3
0
=

Suponer que o = 0.75 (entre o = 0.65 y o = 0.90).

y g g g c
f A A f P p + =
'
0
85 . 0


Usar f
c
' = 420 kg/cm
2
y p
g
= 0.02.

( ) ( )
o
u
g g g g
P
T A kg A A A P
3
441 . 0 441 4200 02 . 0 420 85 . 0
0
~ = = + =

6 m tipico
6 m tipico
6 m tipico
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


89

( )
2
327
75 . 0 441 . 0
36 3
441 . 0
3
cm n
n P
A
u
g
=

= =
o



n (pisos) A
g
(cm
2
) Dimensiones (cm) Refuerzo
(p
g
= 0.02)
5 1635 40 x 40 8 de 22 mm
10 3270 60 x 60 8 de 32 mm
15 4905 70 x 70 12 de 32 mm

Usar amarres y amarres suplementarios en 10 cm.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


90

4. COMPORTAMIENTO Y DISEO DE CONEXIONES DE CONCRETO REFORZADO

4.1 Introduccin a Conexiones de Concreto Reforzado

Hay varios tipos de conexiones viga-columna, comnmente encontradas en prticos de concreto
reforzado.



Las conexiones dan anclaje a las varillas de vigas y columnas, y pueden ser las componentes ms
vulnerabl es. El diseo inteligente de conexiones requiere buen entendimiento de las fuerzas que
actan sobre ellas, y tambin del buen detallado para evitar agrietamiento y congestin innecesario.

Vamos a examinar las acciones aplicadas a cada tipo de conexin , cuando el prtico est sujeto a
cargas laterales mas l as de gravedad:




4.2 Diseo de Conexiones Interiores por el Enfoque del ACI 318-08

Segn el enfoque del ACI 318-08 (Captulo 21), las conexiones interiores viga-columna tienen que
disearse por tres cosas:

1) Corte. En el diseo por corte, la demanda V
u
(calculada como se muestra a continuacin)
tiene que superarse por la resistencia de diseo cortante, calculada como el producto de una
resistencia nominal cortante por el factor o de reduccin de capacidad cortante (0.85). La
resistencia nominal cortante es el producto de un esfuerzo nominal cortante por el rea
efectiva de la conexin. El esfuerzo resistente nominal es mucho ms alto de lo que se
permite para vigas y columnas, pues se piensa que el corte se resiste por compresin en
puntales diagonales altamente confinados.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


91
2) Anclaje. En el diseo por anclaje, no hay requisitos de rigor para conexiones interiores, pues
se piensa que una prdida de anclaje es un problema no de seguridad, sino de servicio. A
continuacin, se demuestra la validez de esta aseveracin.

3) Confinamiento: El Captulo 21 impone requisitos especiales para el confinamiento de
conexiones, para prticos especiales. A continuacin se muestran estos requisitos.
Esencialmente, son equivalentes a los requisitos para rtulas plsticas en las columnas. Para
conexiones interiores, los requisitos se permiten reducir por la mitad, si las conexiones estn
confinadas por vigas que cubren por lo menos el 75% del rea de cada uno de los cuatro
lados de la columna.


4.2.1 Clculo de Fuerzas que Actan sobre las Conexiones Interiores

Los momentos en las vigas se deben primeramente a las cargas laterales, y cambian de sentido
cuando cambian de direccin.




Estas fuerzas se transmiten al ncleo de la conexin a travs de los bloques de esfuerzo compresivo,
y a travs de la adherencia.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


92


Como resultado, tenemos las siguientes fuerzas netas sobre el ncleo de la conexin. El mecanismo
fundamental puede visualizarse en trminos de puntales y tensores.



Adems de los requisitos de confinamiento, tenemos que disear por el corte y el anclaje.
Asumiendo que rtulas plsticas se han formado en l os dos lados de la columna, podemos calcular
el corte resultante en el ncleo de la conexin. Asumamos que e l acero longitudinal ha comenzado
a endurecerse (o ~ 1.25).



Para el equilibrio en el Corte B-B,

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


93

tenemos que tener

columna y s conexion
V C f A V + =
2 1
o


Pero

y s
f A C o
2 2
=

Entonces
( )
columna y s s conexion
V f A A V + = o
12 1



4.2.2 Porqu No Tenemos que Chequear Anclaje en Conexiones Interiores

En la seccin anterior, se asevera que no hay necesidad de chequear los requisitos de anclaje para
una conexin interior. A continuacin, vamos a ver porqu:

Al disear la conexin interior por anclaje, al principio parecera que tendramos que disear para la
condicin siguiente:


Mediante este enfoque, la distancia La distancia tendra que ser suficiente para resistir una
diferencia de esfuerzo por lo menos igual a of
y
.

Sin embargo, la situacin no es tan exigente. De hecho, podemos mantener la resistencia de una
conexin interior an despus de perder toda la adherencia de las varillas. Como se muestra en el
dibujo siguiente, podemos transferir el corte mediante contacto directo entre la columna y el bloque
compresivo de las vigas.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


94


( )
columna y s s conexion
V f A A V + = o
12 1
,

igual que antes. La capacidad en flexin de las vigas se reduce ligeramente comparada con el
equilibrio de antes, pues el hecho de tener tanto el acero de arriba como el de abajo en traccin en las
vigas, reduce el brazo interno de las vigas. No obstante, la conexin trabaja ms o menos bien en
trminos de capacidad.

Sin embargo, queremos evitar la prdida completa de adherencia en conexiones interiores, porque
esta da lugar a una prdida de rigidez y estabilidad del prtico entero. Por lo tanto, la Seccin
21.7.2.3. del ACI 318-08 impone el requisito que
b col
d h 20 >
para conexiones interiores de
prticos especiales.


4.2.3 Significado de los Requisitos del ACI 318-08 para Confinamiento

La Seccin 21.5.2.2 del ACI 318-08 requiere (en general, sin confinamiento por vigas),

yt
c
c sh
ch
g
yt
c c
sh
f
f
b s A pero
A
A
f
f b s
A
' '
09 . 0 1
3 . 0
>
|
|
.
|

\
|
=

Para aclararse ms, los dos requisitos pueden expresarse en trminos de la razn volumtrica.
Suponer 8 varillas longitudinales, y tres amarres en cada direccin. Para una columna cuadrada, con
un rea de amarres igual a A
sh
en cada direccin, el volumen de amarres es aquella A
sh
, multiplicada
por el largo de cada amarre (b
c
), y multiplicada por 2. El volumen de concreto confinado es el
producto del espacio entre amarres (s), multiplicado por el largo de cada amarre (b
c
) al cuadrado.
Multiplicar el numerador y denominador del lado izquierdo de cada ecuacin para expresarlo en
trminos de la razn volumtrica.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


95
( )
|
|
.
|

\
|
=
|
|
.
|

\
|
=
|
|
.
|

\
|
=
|
|
.
|

\
|
|
|
.
|

\
|
=
|
|
.
|

\
|
|
|
.
|

\
|
=
1 60 . 0
1 3 . 0 2
1
3 . 0
2
1
3 . 0
2
2
1
3 . 0
'
'
' 2
' 2
2
'
ch
g
y
c
s
ch
g
y
c
s
ch
g
yt
c c
c
c
s
ch
g
yt
c c
c
c
c
c sh
ch
g
yt
c c
sh
A
A
f
f
A
A
f
f
A
A
f
f b s
b
b s
A
A
f
f b s
b
b s
b s
b A
A
A
f
f b s
A
p
p
p
yt
c
s
yt
c
c
c
c
s
yt
c
c
c
c
c
c sh
yt
c
c sh
f
f
f
f
b s
b
b s
f
f
b s
b
b s
b s
b A
f
f
b s A
'
' 2
' 2
2
'
18 . 0
09 . 0
2
09 . 0
2
2
09 . 0
>
>
|
|
.
|

\
|
>
|
|
.
|

\
|
>
p
p

Comparar con un factor de 0.45 de la Seccin
10.9.3 del ACI 318-08.
Para una columna cuadrada, esta ecuacin nunca
va a gobernar.


4.2.4 Ejemplo del Diseo de una Conexin Interior por el ACI 318-08

Disear esta conexin interior, suponiendo que pertenece a un prtico especial:



Tenemos que disear la conexin por corte, por anclaje, y por confinamiento.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


96

Diseo por Corte:

Tenernos que calcular primero el corte en las columnas. Supongamos que existen puntos de inflexin
en la mitad de cada columna, y que los pisos tienen altura de 4m.



Usar

( )
( )
( )
T
cm
cm T
V
cm T cm cm kg cm M
cm T cm cm kg cm M
d d f A M
col
y s n
47 . 9
400
2423 1363
2423
2
8 . 1
2
4 . 2
2 . 1 2 8 55 / 4200 4 . 2
4
3
1363
2
8 . 1
2
4 . 2
2 . 1 2 8 55 / 4200 8 . 1
4
3
2 2
1
2 2
2
'
=
+
=
=
|
.
|

\
|
=
= |
.
|

\
|
=
~
t
t



( )
( )
T V
T T T cm kg V
V f A A V
conexion
conexion
columna y s s conexion
8 . 101
47 . 9 3 . 111 47 . 9 / 4200 25 . 1 63 . 7 57 . 13
2
2 1
=
= + =
+ = o




Calcular la capacidad cortante de la conexin por

T
T V
V
A v V
u requerido
n
conexion conexion n
8 . 119
85 . 0
8 . 101
= = =
=
o


Suponiendo vigas confinantes en los cuatro lados de la conexin,

conexion c n
A f V
'
22 . 5 =
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


97

El rea efectiva de la conexin se define en la Seccin 21.7.4.1 del ACI 318-08:

+
+
=
x b
h b
h A
col j
2
min




En nuestro caso, el ( )
col
b x b = + 2 gobierna.

( ) Bien V T kg cm V
requerido
n n
> = = = 315 147 , 315 60 281 22 . 5
2



Diseo por Anclaje:

Ahora revisar el anclaje. Por cuanto no hay varillas terminadas dentro de la conexin, no hay
requisitos. Sin embargo, la Seccin 21.7.2.3 requiere que
b col
d h 20 > para conexiones de prticos
especiales. En nuestro caso, cm cm d
b
64 2 . 3 20 20 = = . En el caso de un prtico especial,
habra que aumentar un poco el tamao de la columna.


Diseo por Confinamiento:

Finalmente, hay que revisar el confinamiento (Seccin 21.7.3):

yt
c
c sh
ch
g
yt
c c
sh
f
f
b s A pero
A
A
f
f b s
A
' '
09 . 0
2
1
1
3 . 0
2
1
|
.
|

\
|
>
|
|
.
|

\
|
|
.
|

\
|
=

y cm s 15 s .

En las ecuaciones de arriba, los factores de (1/2) se deben a la existencia de vigas confinantes.

Entre poco, vamos a ver el significado de estos requisitos. Por ahora,

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


98
2 2
2
2
2
2
2
2
' '
57 . 1 75 . 1
/ 4200
/ 281
) 8 60 ( 10 09 . 0
2
1
1
52
60
/ 4200
/ 281 ) 8 60 ( 10 3 . 0
2
1
09 . 0
2
1
1
3 . 0
2
1
cm A pero cm A
cm kg
cm kg
cm cm A pero
cm kg
cm kg cm cm
A
f
f
b s A pero
A
A
f
f b s
A
sh sh
sh
sh
yt
c
c sh
ch
g
yt
c c
sh
> =
|
.
|

\
|
>
|
|
.
|

\
|


|
.
|

\
|
=
|
.
|

\
|
>
|
|
.
|

\
|
|
.
|

\
|
=


Suponiendo 1 amarre cerrado y un amarre suplementario,

2
2
var
58 . 0
3
75 . 1
cm
cm
A
illa
= =

Usar amarres de 9 mm y amarres suplementarios en 10 cm.



4.3 Diseo de Conexiones Exteriores por el Enfoque del ACI 318-08

Segn el enfoque del ACI 318-08 (Captulo 21), las conexiones exteriores viga-columna tienen que
disearse por tres cosas:

1) Corte. Se calcula igual que para las conexiones interiores. Por cuanto las conexiones
exteriores tienen solamente una viga, el corte de diseo es ms o menos la mitad del corte en
una conexin interior. Sin embargo, la capacidad cortante es tambin menor, pues las
conexiones exteriores no pueden tener vigas confinantes en los cuatro lados de la conexin.
Al igual que antes, el esfuerzo resistente nominal es mucho ms alto de lo que se permite
para vigas y columnas, pues se piensa que el corte se resiste por compresin en puntales
diagonales altamente confinados.

2) Anclaje. A diferencia de las conexiones interiores, s hay requisitos especficas para el
anclaje de las varillas de las vigas en las conexiones exteriores, pues una falla de tal anclaje
conduce a una prdida total de resistencia de la conexin. Debido al poco ancho de una
columna tpica, normalmente se necesita un gancho de 90 grados. Sin embargo, la longitud
de desarrollo necesaria puede reducirse comparada con la requerida en el Captulo 12 del
ACI 318-08, debido al estado de confinamiento que existe en la conexin.

3) Confinamiento: El Captulo 21 impone requisitos especiales para el confinamiento de
conexiones, para prticos especiales. A continuacin se muestran estos requisitos.
Esencialmente, son equivalentes a los requisitos para rtulas plsticas en las columnas. A
diferencia de las conexiones interiores, los requisitos no se pueden reducir por la mitad por
confinamiento por vigas en los cuatro lados de la columna, pues las conexiones exteriores
normalmente no tienen viga confinante en el lado de afuera.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


99
4.3.1 Clculo de Fuerzas que Actan sobre las Conexiones Exteriores

Los momentos en las vigas se deben primeramente a las cargas laterales, y cambian de sentido
cuando cambian de direccin.


Estas fuerzas se transmiten al ncleo de la conexin a travs de los bloques de esfuerzo compresivo,
y a travs de la adherencia.



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


100
Como resultado, tenemos las siguientes fuerzas netas sobre el ncleo de la conexin. El mecanismo
fundamental puede visualizarse en trminos de puntales y tensores.



Adems de los requisitos de confinamiento, tenemos que disear por el corte y el anclaje.
Asumiendo que rtulas plsticas se han formado en l os dos lados de la columna, podemos calcular
el corte resultante en el ncleo de la conexin. Asumamos que e l acero longitudinal ha comenzado
a endurecerse (o ~ 1.25).



Para el equilibrio en el Corte B-B, tenemos que tener

columna y s conexion
V f A V = o


4.3.2 Porqu S Tenemos que Chequear Anclaje en Conexiones Exteriores

A diferencia de las conexiones interiores, las conexiones exteriores tienen que disearse por anclaje.
Obviamente, una falla de anclaje pone en peligro el prtico.

Ensayos experimentales han mostrado que bajo cargas repetidas, se pierde la adherencia en el tramo
recto de la varilla, de modo que la mayora del anclaje depende del gancho. La fuerza de traccin en
la varilla tiende a enderezar el gancho, si ste no est restringido por el acero confinante de la
columna. Con varillas relativamente grandes, es a veces difcil proveerle suficiente anclaje en la
columna, an con el efecto del gancho. Sin embargo, debido al buen confinamiento que existe
dentro del ncleo de la conexin , es posible usar menor longitud de anclaje, de lo que se especifica
en el Captulo 12 del ACI 318-08.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


101


Para conexiones exteriores de prticos especiales, la Seccin 21.7.5.1 del ACI 318-08 requiere una
longitud de desarrollo, para un gancho de 90 grados dentro de un ncleo confinado, de

'
17 . 17
c
b y
dh
f
d f
=



4.3.3 Ejemplo del Diseo de una Conexin Exterior por el ACI 318-08

Disear esta conexin exterior, suponiendo que pertenece a un prtico especial:



Tenemos que disear la conexin por corte, por anclaje, y por confinamiento.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


102

Diseo por Corte:

Tenernos que calcular primero el corte en las columnas. Supongamos que existen puntos de inflexin
en la mitad de cada columna, y que los pisos tienen altura de 4m.



Usar

( )
( )
T
cm
cm T
V
cm T cm cm kg cm M
d d f A M
col
y s n
06 . 6
400
2423
2423
2
8 . 1
2
4 . 2
2 . 1 2 8 55 / 4200 4 . 2
4
3
2 2
1
'
=

=
=
|
.
|

\
|
=
~
t



T V
T T T cm kg V
V f A V
conexion
conexion
columna y s conexion
18 . 65
06 . 6 2 . 71 06 . 6 / 4200 25 . 1 57 . 13
2
1
=
= =
= o




Calcular la capacidad cortante de la conexin por

T
T V
V
A v V
u requerido
n
conexion conexion n
69 . 76
85 . 0
18 . 65
= = =
=
o


Puesto que no tenemos vigas confinantes en solamente tres lados de la conexin,

conexion c n
A f V
'
92 . 3 =

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


103
El rea efectiva de la conexin se define en la Seccin 21.7.4.1 del ACI 318-08:

+
+
=
x b
h b
h A
col j
2
min




En nuestro caso, el ( )
col
b x b = + 2 gobierna.
( ) Bien V T kg cm V
requerido
n n
> = = = 237 560 , 236 60 281 92 . 3
2



Diseo por Anclaje:

Segn la Seccin 21.7.5.1 del ACI 318-08,

cm
cm kg
cm cm kg
f
d f
c
b y
dh
02 . 35
/ 281 17 . 17
4 . 2 / 4200
17 . 17
2
2
'
=

= =


Esta es la distancia entre el plano crtico (punto de esfuerzo mximo a lo largo de la varilla) y la
parte posterior del gancho. La longitud disponible es la distancia entre la cara exterior de los
amarres de la columna en el lado de viga, y la cara interior de los amarres en el lado opuesto.

Esta distancia es

Bien cm cm cm d nto recubrimie h
amarre col le disisponib
35 8 . 50 2 . 1 4 2 60 2 > = = =


Diseo por Confinamiento:

Finalmente, hay que revisar el confinamiento (Seccin 21.7.3):

yt
c
c sh
ch
g
yt
c c
sh
f
f
b s A pero
A
A
f
f b s
A
' '
09 . 0 1
3 . 0
>
|
|
.
|

\
|
=

y cm s 15 s .

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


104
Esta vez, no hay factores de (1/2), pues hay vigas confinantes slo en tres lados de la conexin. La
segunda ecuacin no gobierna para columnas cuadradas.

2
2
2
2
2
'
46 . 3
1
52
60
/ 4200
/ 281 ) 8 60 ( 10 3 . 0
1
3 . 0
cm A
cm kg
cm kg cm cm
A
A
A
f
f b s
A
sh
sh
ch
g
yt
c c
sh
=
|
|
.
|

\
|


=
|
|
.
|

\
|
=


Suponiendo 1 amarre cerrado y un amarre suplementario,

2
2
var
15 . 1
3
46 . 3
cm
cm
A
illa
= =

Usar amarres de 12 mm y amarres suplementarios en 10 cm.



4.4 Conexiones de Rodilla
Las conexiones de rodilla generalmente ocurren en el ltimo piso de un edificio , donde las cargas
son pequeas. El reto principal consiste en la colocacin de refuerzo suplementario para controlar el
agrietamiento bajo cargas de servicio. Abajo se muestran ejemplos de detalles malos, tpicos, y
mejores.





Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


105



Lo mas esencial es tener refuerzo en sentido diagonal, atravesando las orientaciones de grietas
diagonales en la conexin.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


106


5. REPASO DE PRINCIPIOS DE DISEO PARA ENSAMBLAGES DCILES DE
CONCRETO REFORZADO

Hasta ahora, hemos estudiado el comportamiento de vigas, columnas, y conexiones viga-columna del
concreto reforzado. Hemos enfatizado el uso de concreto confinado para desarrollar caractersticas
favorables de disipacin de energa para rtulas plsticas, y capacidad grande de rotacin plstica
disponible en o arriba de M
n
.

Hemos estudiado cmo mantener estas caractersticas favorables en una regin crtica sujeta a corte y
fuerza axial, usando refuerzo transversal cercanamente espaciado para resistir corte y proveer
confinamiento. Hemos aprendido a demorar el deterioro por corte en rtulas de columna, diseando
la columna para que su resistencia al agrietamiento diagonal exceda su resistencia en flexin.

Hemos estudiado procedimientos para disear las conexiones viga-columna para ser por lo menos
suficientemente Fuertes para resistir las fuerzas mximas posibles que se les pueden aplicar por los
miembros que conectan.

Los objetivos de esta seccin son los siguientes:

1) repasar estos principios y procedimientos de diseo; y

2) compararlos con las provisiones de una norma tpica para el diseo sismorresistente de
concreto reforzado (el Captulo 21 del ACI 318-08).



5.1 Diseo de Vigas de Concreto Reforzado

Hemos visto que el comportamiento dctil puede lograrse mediante lo siguiente:

1) usar porcentajes bajos de refuerzo longitudinal en traccin;

2) usar refuerzo longitudinal compresivo;

3) usar refuerzo transversal, cercanamente espaciado, para
a) dar buen u
p
mediante mtodos tericos (tales como Park y Kent) o
empricos (tales como Mattock y Corley)
b) prevenir el pandeo inelstico de refuerzo longitudinal (s s 4 d
b
)
c) resistir el corte producido por M
max
en rtulas plsticas.


En general, esto require una razn volumtrica de por lo menos unos 0.005, correspondiente
aproximadamente a amarres de 12 mm en 20 cm.

Ahora comparar estas guas generales con los requisitos especficos del Captulo 21 del ACI 318-08,
para elementos de prticos especiales (Categora de Diseo Ssmico D y arriba:
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


107
















Notar la semejanza a nuestro principio bsico
que requiere una razn de luz a profundidad
total de por lo menos 3.5 para comportamiento
dominado por flexin.













Nuestro punto de arranque para el diseo de
vigas es un porcentaje de refuerzo en traccin
de unos 0.01.


Nuestro diseo instantneo de vigas
involucra capacidad positiva en flexin de por
lo menos la mitad de la mxima capacidad
negativa. Involucra adems capacidad positive
en flexin de por lo menos un cuarto de la
capacidad negativa.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


108








El espacio mximo de refuerzo transversal en
empalmes no debe exceder d/4 o 10 cm. Notar
la semejanza con nuestro criterio para prevenir
o demorar el pandeo de refuerzo longitudinal.


No usar traslapes en rtulas plsticas. Hemos
hablado sobre cmo esto reduce la capacidad
inelstica de rotacin previniendo la cedencia
sobre mucho del largo de la rtula, y adems
reduce el largo efectivo de la columna,
aumentando as la demanda de corte.








Proveer estribos cerrados a lo largo de una
longitud esperada de rtula de 2d.






Colocar el primer estribo cerrado unos 5 cm del
costado de la columna.



El espacio entre estribos cerrados no debe ser
mayor que d/4, 8 d
b
, 24 d
estribo
, o 30 cm.







Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


109















Para facilitar la construccin, se pueden usar
estribos cerrados de orientaciones alternadas.

















Usar diseo por capacidad para el diseo
cortante de vigas.











Si la carga axial es baja, disear suficiente
refuerzo transversal para resistir todo el corte.
Comparar con nuestros diagramas de
interaccin momento-fuerza axial, limitados
por corte.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


110
5.2 Diseo de Columnas de Concreto Reforzado
Hemos visto que el comportamiento dctil puede lograrse usando una razn volumtrica de unos 0.01
(correspondiente aproximadamente a amarres cerrados y amarres suplementarios de 12 mm en 10 cm).


1) Usar refuerzo transversal, cercanamente espaciado, para:
a) dar buen u
p

b) prevenir el pandeo inelstico de refuerzo longitudinal (s s 4 d
b
)
c) resistir los cortes consistentes con el desarrollo de momentos mximos en los dos
extremos de la columna
d) hacer el diagrama de interaccin momento fuerza axial para la seccin confinada (c
c
max
= 0.01) tan fuerte como el diagrama para la seccin original (c
c max
= 0.003) en
cargas axiales bajas

2) Usar cargas axiales menores al P
balanceado
(aproximadamente un tercio de la capacidad en
compresin pura)

3) Usar L/h > 3.5 (columna empotrada). Esto corresponde aproximadamente a a/d > 2, or L/d >
4.



Ahora comparar estas guas generales con los requisitos especficos del Captulo 21 del ACI 318-08:


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


111


























columna fuerte, viga dbil



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


112


















Nuestro diseo instantneo para columnas
usa porcentajes de refuerzo longitudinal de
0.02.















Hay que colocar refuerzo transversal en zonas
de rtulas plsticas, y tal refuerzo debe
extenderse por una distancia no menos que d,
un sexto de la luz clara, o 45 cm.



Hay que espaciar amarres suplementarios en
no ms de 36 cm en la seccin de la columna.








Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


113









El espacio del refuerzo transversal no debe ser
mayor que b/4, d/4, 6 d
b















para estribos cerrados con un amarre
suplementario en cada direccin:

yt
c
s
f
f
'
12 . 0 = p (repetido)
|
|
.
|

\
|
= 1 45 . 0
'
ch
g
yt
c
s
A
A
f
f
p


equivalente a
|
|
.
|

\
|
= 1 60 . 0
'
ch
g
yt
c
s
A
A
f
f
p
equivalente a

yt
c
s
f
f
'
18 . 0 = p


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


114








































Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


115












Disear columnas por corte usando el diseo
por capacidad.












Si la carga axial es baja, disear suficiente
refuerzo transversal para resistir todo el corte.
Comparar con nuestros diagramas de
interaccin momento-fuerza axial, limitados
por corte.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


116
5.3 Diseo de Conexiones Viga-Columna de Concreto Reforzado

Hemos visto que las conexiones viga-columna deben disearse por los siguientes pasos:

1) Limitar corte global en la conexin a
conexion c
A f
'
22 . 5 13 . 3


2) Proveer suficiente anclaje
a) para conexiones interiores, proveer suficiente ancho de columna para demorar la
degradacin de varillas rectas que pasan por la conexin.
b) para conexiones exteriores, disear los ganchos confinados para desarrollar 1.25 f
y



3) Continuar el refuerzo confinante requerido de la columna, por la conexin. Los requisitos para
refuerzo confinante pueden reducirse si confinamiento adicional est disponible en los cuatro
lados de la conexin.


4) Proveer algn refuerzo vertical de la columna, ligeramente estresado, para resistir cortes
verticales.



Ahora comparar estas guas generales con los requisitos especficos del Captulo 21 del ACI 318-08:


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


117


















Calcular cortes en la conexin suponiendo
que el refuerzo a flexin est en 1.25 f
y
.


Para conexiones exteriores, anclar el refuerzo
longitudinal de las vigas.




Usar un ancho mnimo de las columnas para
conexiones interiores.










Se requiere un espacio normal de refuerzo
confinante de la columna (unos 12 mm en 10
cm), a menos que haya vigas confinantes en
los cuatro lados. En tales ubicaciones, el
espacio puede aumentarse a 15 cm.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


118









capacidad nominal cortante de la conexin




Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


119






requisitos de desarrollo para varillas dobladas
en traccin.





















Aumentar las longitudes embebidas fuera del
ncleo confinado.




Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


120

6. COMPORTAMIENTO Y DISEO DE MUROS CORTANTES DE CONCRETO
REFORZADO

6.1 Introduccin a Muros Cortantes de Concreto Reforzado
El trmino "muro cortante" es parcialmente mal puesto, pues la realidad estamos hablando de
elementos cuyo comportamiento se gobierna por flexin. Los muros cortantes pueden clasificarse
como se muestra abajo:



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


121

Si esperamos buen comportamiento inelstico, queremos que la falla del muro sea gobernada por
flexin.


6.2 Resistencia a Flexin de Muros Cortantes
En estudiar el comportamiento de muros, lo primero que hay que hacer es desarrollar tcnicas para
predecir su comportamiento a flexin, o sea, calcular curvas de momento-curvatura. En general,
podemos usar los mismos principios que usamos para columnas ordinarias.



Debido a que los muros cortantes tienen mltiples capas de refuerzo, este tipo de clculo a mano
puede ser fastidioso. Es ms fcil usar hojas de clculo.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


122
La hoja que acompaa esta seccin muestra una manera de hacer tal diagrama. Cada fila de la hoja
representa un punto en el diagrama de interaccin, y corresponde a valores incrementadas de (c/d) a
medida que se mueve hacia arriba en el diagrama y en la hoja. La deformacin unitaria en el
concreto es constante en 0.003. Cada ubicacin distinta del eje neutro define una gradiente de
deformaciones unitarias por la profundidad de la seccin. El bloque compresivo en el concreto se
idealiza como un bloque equivalente rectangular cuya altura es 0.85 f
c
' y cuya profundidad es |
1
c .
El esfuerzo en cada capa de refuerzo longitudinal se calcula por Excel mediante una serie de
aseveraciones condicionales. La deformacin unitaria en cada capa de acero se calcula con base en
la deformacin unitaria en la fibra extrema compresiva del concreto y la razn entre la distancia
entre el eje neutro y la capa de acero, y la distancia entre el eje neutro y la fibra extrema compresiva
de concreto. Tal deformacin unitaria se multiplica por el mdulo elstico del acero. Si el valor
resultante indica un esfuerzo positivo (compresivo), el esfuerzo se pone en cero, pues normalmente
no es posible restringir lateralmente el acero longitudinal en un muro (no hay estribos cerrados). Si
el valor resultante indica un esfuerzo negativo (en traccin) de mayor magnitud que el esfuerzo
especificado de cedencia, el esfuerzo se pone en el negativo del esfuerzo especificado de cedencia.
La nica posibilidad remanente es que el valor resultante es un valor negativo (en traccin) menor o
igual en magnitud que el esfuerzo especificado de cedencia, caso en el cual el esfuerzo se pone en
ese valor.

Un ejemplo de tal diagrama de interaccin M-N se muestra abajo, para un muro cortante con
profundidad total de 6.1 m, un espesor de 30 cm, concreto de 281 kg/cm2, y dos capas de varillas de
12 mm, espaciados en 30 cm en cada direccin.




0
500
1000
1500
2000
2500
3000
3500
4000
0 500 1000 1500 2000 2500 3000 3500 4000
P
n
,

T
Mn, T-m
Diagrama de Interaccion M-N para Muro Cortante
f'c=281 kg/cm2, 6.1 m de largo, 30 cm de espesor, 2 varillas de 12 mm en 30 cm
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


123
Por cuanto el programa permite solamente 7 capas o menos de refuerzo, se supone que el refuerzo
interior est aglomerado en intervalos de unos 0.9 m, como se muestra abajo.

.


Es probable que se puede lograr una curvatura ltima ms grande an, igual que con las columnas ,
confinando el concreto en los extremos de la seccin.



Pero an si se le provee confinamiento, el muro todava puede fallar por pandeo lateral del ncleo
confinado. Esto puede demorarse poniendo aletas en los extremos de la seccin. El concreto en los
extremos del muro debe confinarse, igual que para una columna.



area real es de 2.58 cm2 cada 30 cm
91.4 91.4 76.2 76.2 91.4 91.4 45.7
30 cm
6.09 m
varillas de 12 mm cada 30 cm
area aglomerada es de 16.39 cm2 cada 91.4 cm (aproximadamente)
15 30
3.87 cm2 3.87 cm2
2.58 cm2
45.7
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


124

6.3 Capacidad Cortante de Muros Cortantes

Al igual que las columnas, la capacidad cortante de muro depende de contribuciones del concreto
(Vc) y del acero (puntal y tensor) (Vs). Para investigar la capacidad cortante proveniente del
concreto, hay que considerar dos posibles modos de falla:

o falla por agrietamiento del alma; y
o falla por agrietamiento cortante-flexin


6.3.1 Falla por Agrietamiento del Alma

La grieta se produce en el centro del alma, debido a esfuerzos principales de
traccin.

Consideremos el estado de esfuerzo en un elemento en el centro del alma:


h
V
v
w
2
3
max
=

h
N
n
w

=



h
N
h
V
h
N
f
v
n n
f
w w w
tp
principal traccion
2 2
3
2
2 2
2 2
2
2

|
|
.
|

\
|
+
|
|
.
|

\
|
=
+
|
.
|

\
|
+ =


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


125

Resultados experimentales indican que grietas inclinadas se van a formar cuando

2 '
/ 0 . 2 cm kg f f
c tp
~
,

y que el lmite inferior se da por

2 '
/ 1 . 1 cm kg f f
c tp
~


Sustituyendo el segundo valor, obtenemos

2 2
'
2 2
'
2
3
2 2
1 . 1
2 2
3
2
1 . 1
|
|
.
|

\
|
+
|
|
.
|

\
|
= +

|
|
.
|

\
|
+
|
|
.
|

\
|
=
h
V
h
N
h
N
f
h
N
h
V
h
N
f
w w w
c
w w w
c




Cuadrando los dos lados,

( ) ( )
( )
( )
( )
h f
N
f h V
h f
N
f
h
V
h
V
f h
N
f
h
V
h
N
h
N
h
N
f f
h
V
h
N
h
N
f
w c
c w
w c
c
w
w
c w
c
w w w w
c c
w w w
c



'
'
'
'
2
'
2
'
2 2 2
'
2
'
2 2
'
1 . 1
1 1 . 1
3
2
1 . 1
1 1 . 1
2
3
2
3
1 . 1
1 1 . 1
2
3
2 2 2
1 . 1 2 1 . 1
2
3
2 2
1 . 1
+
|
.
|

\
|
=
+ =
|
|
.
|

\
|
=
|
|
.
|

\
|
+
|
|
.
|

\
|
+
|
|
.
|

\
|
=
|
|
.
|

\
|
+
|
|
.
|

\
|
+
|
|
.
|

\
|
+
|
|
.
|

\
|
= +


Ahora vamos, como si fuera, a caminar en un crculo. Primero vamos a convertir la ecuacin que
acabamos de derivar en trminos de fuerzas, a esfuerzos; y luego, la vamos a convertir nuevamente a
fuerzas. En el primer paso del proceso, tendremos que dividir por un valor de bd; en el segundo
paso, tendremos que multiplicar por el mismo valor. Luego vamos a explicar el porqu.

Por ahora, el valor del ejercicio consiste en establecer un valor sensato de d para secciones con
refuerzo longitudinal distribuido.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


126
o Segn la definicin tradicional, d es la distancia entre el centroide del acero en traccin, y la
fibra extrema compresiva del concreto. Esta definicin funciona bien cuando se trata de una
seccin con pocas capas de acero en traccin.



Segn la figura de arriba, al agregar una varilla adicional, el peralte efectivo d se reduce de d
1
a d
2
.
Por lo tanto, se reduce la capacidad cortante. Esta inferencia es claramente contra-intuitiva.

Para eliminar este dilema, hay que cambiar la definicin de d. En lugar de la de arriba, se define d
como la distancia entre la capa extrema de acero en traccin, y el centroide del bloque compresivo de
concreto. El resultado de esta definicin se muestra abajo. Se nota que el agregar ms acero apenas
disminuye d, y esta definicin es ms sensata para secciones de concreto con mltiples capas de
refuerzo.


Para muros de concreto con mltiples capas de refuerzo, distribuidas de varias maneras a lo alto de la
seccin, podemos decir que d es aproximadamente igual a
w
8 . 0 .

d
1
d
2
d
1
d
2
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


127


Ahora que hemos aclarado la definicin de d, podemos proceder con nuestra caminata circular.
( )
( )
h f
N
f v
h f
N
f v
h f
N
f h
h
v
h
V
bd
V
v
h f
N
f h V
w c
c c
w c
c c
w c
c w
w
c
w
c
w c
c w

'
'
'
'
'
'
'
'
1 . 1
1 88 . 0
1 . 1
1
8 . 0 3
1 . 1 2
1 . 1
1 1 . 1
3
2
8 . 0
1
8 . 0
1 . 1
1 1 . 1
3
2
+ =
+
|
.
|

\
|

=
+
|
.
|

\
|
|
|
.
|

\
|
=
= =
+
|
.
|

\
|
=

Para valores tpicos de
h
N
w

y
'
c
f , esta expresin puede aproximarse por
h
N
f v
w
u
c c
4
88 . 0
'
+ =

Convirtiendo nuevamente al formato de fuerzas,

( )
w c c c
d d h v d b v V 8 . 0 = =


w
u
c c
d N
d h f V
4
88 . 0
'
+ =
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


128
6.3.2 Falla por Agrietamiento Cortante-Flexin

Las provisiones sobre agrietamiento cortante-flexin marcan uno de los aspectos ms curiosos del
ACI 318-08. La falla en cuestin es de veras una falla por flexin, pero se convierte en trminos de
corte mediante la razn (M/Vd).

En la figura de abajo, se muestra la base de un muro cortante, con los diagramas correspondientes de
corte y momento.



Se muestra una grieta que comienza como una grieta por flexin, pero vira despus. La resistencia
del concreto al agrietamiento por flexin (mdulo de rotura) es de unos
'
0 . 3 7 . 2
c
f , y tiene
lmite inferior de unos

2 '
/ 6 . 1 cm kg f f
c t
>

En el muro, el esfuerzo en traccin en el punto donde comienza la grieta, es

|
|
.
|

\
|
+ =
+ =
|
|
.
|

\
|
|
.
|

\
|
+ =
= =
h
N
f
h
M
h
N
f
h
M
A
N
f
I
c M
f
A
N
I
c M
f
w
c
w
ag
w
c
w
w
ag
c
ag
c
ag
t

'
2
'
3
'
'
6 . 1
6
6 . 1
12
2
6 . 1
6 . 1


Ahora vamos a expresar esta ecuacin en trminos de corte:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


129
|
.
|

\
|

=
|
.
|

\
|

=
~
|
.
|

\
|
=
2 2
2
w
ag
w
ag
w
ag
V
M
M
z
M
V
V
M
z
z V M



Sustituyendo,

|
.
|

\
|

|
|
.
|

\
|
+
=
|
.
|

\
|

+
=
|
.
|

\
|

|
|
.
|

\
|
+
=
2
6
1
75 . 3
2
6
1
6
6 . 1
2
6 . 1
6
'
'
2
'
2
w
w
w
w
c
w
w
w c
w
w
w
c
w
V
M
h
h
N
f
V
V
M
N f
h
V
V
M
h
N
f
h
V



Pero d d
w w
25 . 1 8 . 0 = = .

( )
|
.
|

\
|

|
|
.
|

\
|
+
=
|
.
|

\
|

|
|
.
|

\
|
+
=
2
2 . 0 33 . 0
2
25 . 1
6
1
75 . 3
'
'
w
w
c w
c
w
w
w
c
w
V
M
d h
h
N
f
V
V
M
d h
h
N
f
V




Pero ensayos han mostrado que la resistencia del concreto al agrietamiento inclinado es
consistentemente mayor que esto. Se necesita un pequeo corte adicional (unos
2 '
/ 16 . 0 cm kg f
c
)
para transforma la grieta por flexin inicial, a una grieta inclinada cortante-flexin.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


130
d h
V
M
h
N
f
f V
w
w
c w
c c

|
.
|

\
|

|
|
.
|

\
|
+
+ =
2
2 . 0 33 . 0
16 . 0
'
'




6.3.3 Sntesis de Modos de Falla Cortante Gobernados por V
c


Las ecuaciones derivadas en estas secciones representan, respectivamente, las ecuaciones 11-33y 11-
34 del ACI 318-08. Dadas las dos expresiones para V
c
gobernadas por

a) agrietamiento cortante del alma; y
b) agrietamiento cortante-flexin,

para un valor dado de M
u
/ V
u
, la expresin que de el menor valor de V
c
va a gobernar. Para razones
altas de M
u
/ V
u
, la ecuacin para agrietamiento cortante-flexin va a gobernar, y V
c
se acerca a
d h f
c
'
16 . 0 . No sera razonable tener un valor lmite de Vc menor que el valor correspondiente a
vigas ( d h f
c
'
53 . 0 ). Entonces, tomamos
d h f V
c c
'
53 . 0 >

Al graficar las tres ecuaciones en el mismo juego de ejes, obtenemos lo siguiente.


6.3.4 Corte Resistido por Refuerzo Transversal
El corte resistido por refuerzo transversal se calcula de forma semejante a lo que se hace para otros
miembros.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


131
h f V
s
f h s
s
d
f h s V
h s A
s
d
f A V
w y t s
w
y t y t s
t v
y t s

p
p p
p
8 . 0
8 . 0
=
= =
=
=


Como hemos comentado anteriormente, la
resistencia V
s
realmente se refiere a una
resistencia tipo puntales y tensores.

Esta es la resistencia contribuida por el acero,
despus de la formacin de grietas inclinadas. Si
queremos proporcionarle suficiente refuerzo para
que la resistencia por acero sea por lo menos igual a la mnima resistencia que esperamos al
concreto, podemos calcular cunto acero transversal necesitamos:

( )
y
c
t
w c w y t
c w y t
c imo c s
f
f
h f h f
d h f h f
d h f V V
'
'
'
'
min
53 . 0
8 . 0 53 . 0 8 . 0
53 . 0 8 . 0
53 . 0
=
=
=
= =
p
p
p



Para valores tpicos de f
y
y f
c
', 0025 . 0 ~
t
p . Entonces,
( )
d h f V
d h f V V V
c n
c s c n
'
'
06 . 1
53 . 0 2
>
> + =

Esto nos da el grfico siguiente de V
n mnimo
en funcin de M/V:


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


132
6.4 Diseo de Muros Cortantes para Cargas Monotnicas
El diseo de muros cortantes para cargas monotnicas involucra los siguientes pasos:

o diseo por combinaciones de carga axial y momento (refuerzo longitudinal);

o diseo por corte (rea y refuerzo transversal)


6.4.1 Diseo de Muros Cortantes por Carga Axial y Momento

Comenzar suponiendo refuerzo longitudinal (vertical) por flexin 0025 . 0 ~

p , con refuerzo
distribuido uniformemente por la profundidad de la seccin (el largo en planta del muro). Este
refuerzo cumple con los requisitos mnimos de la Seccin 21.9.2.1 del ACI 318-08. Verificar la
capacidad usando una hoja de clculo sencilla.


Lmites de espacio:

s
3
45
3
w
cm
h
s


(Secciones 14.3.5 y 11.9.9.5 del ACI 318-08)


6.4.2 Diseo de Muros Cortantes por Corte


Acero Transversal (Horizontal) por Corte

Comenzar suponiendo refuerzo transversal (horizontal) por corte 0025 . 0 ~
t
p , con refuerzo
distribuido uniformemente por lo alto del muro. Este refuerzo cumple con los requisitos mnimos de
la Seccin 11.9.9.3 del ACI 318-08. Verificar la capacidad usando una hoja de clculo sencilla.

s c n
V V V + =

>

|
.
|

\
|

|
|
.
|

\
|
+
+
+
=
d h f V pero d h
V
M
h
N
f
f
d N
d h f
de menor V
c c
w
w
c w
c
w
u
c
c
'
'
'
'
53 . 0
2
2 . 0 33 . 0
16 . 0
4
88 . 0



s
d
f A V
y t s
=

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


133

Lmites de espacio:

s
cm
h s
w
45
3
5


(Seccin 11.9.9.3 del ACI 318-08)



Lmite Impuesto por Corte sobre el Acero Longitudinal (Vertical)

Finalmente, hay que verificar que el refuerzo longitudinal (vertical) por corte 0025 . 0 >

p , con
refuerzo distribuido uniformemente por la profundidad de la seccin (el largo en planta del muro).
Este refuerzo cumple con los requisitos mnimos de la Seccin 11.9.9.4 del ACI 318-08.


( ) 0025 . 0 5 . 2 5 . 0 0025 . 0
|
|
.
|

\
|
+ >
t
w
w
h
p p

pero

p no tiene que exceder a


t
p .


Lmites de espacio:

s
cm
h s
w
45
3
3


(Seccin 11.9.9.5 del ACI 318-08)

Notar que estos lmites son iguales a los para refuerzo longitudinal (vertical) por flexin.

Este requisito fue dirigido originalmente hacia muros chatos, los cuales normalmente necesitan muy
poco refuerzo vertical por flexin, pero mucho por corte (semejante en concepto al uso de refuerzo
longitudinal adicional en vigas profundas). En muros altos, el lmite impuesto por corte sobre el
acero longitudinal (vertical) normalmente excede por mucho el valor antes establecido de
t
p . No
es necesario poner adicional refuerzo vertical por corte.


6.5 Diseo Instantneo para Muros Cortantes
En secciones previas, hemos estudiado enfoques simplificados para el diseo de vigas continuas y
columnas. Podemos aplicar enfoque semejante al diseo de muros cortantes.

1) Usar el punto de arranque que se muestra abajo.



Se justifican de la siguiente manera:
30 cm
6.09 m
varillas de 12 mm cada 30 cm
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


134

o El espesor de 30 cm es prcticamente la menor dimensin posible, pues cuando se
restan dos recubrimientos de 4 cm cada uno, mas dos mallas de refuerzo de 2.4 cm
cada una, el espacio remanente en medio es de cm 17 ) 4 . 2 ( 2 ) 4 ( 2 30 = , casi el
espacio ms angosto que permite el uso de un vibrador.

o Dos mallas de varillas de 12 mm espaciadas en 30 cm en cada direccin da un
porcentaje de refuerzo en cada direccin de
( )
( )
0025 . 0 00251 . 0
30
2 . 1
4
2
2
2
> =

= = =
cm
cm
A
A
concreto
acero
t
t
p p



o Esto satisface los requisitos mnimos de refuerzo longitudinal y transversal, y
adems los requisitos de espacio mximo entre varillas.


2) Si se necesita ms capacidad en flexin (y normalmente no se necesita), hay que agregar
elementos verticales de borde.



6.6 Ejemplo de Diseo de un Muro Cortante

Disear el muro cortante que se muestra a la izquierda.

Suponer un espacio de 6 m entre lneas de muros, y una presin
no mayorada por viento de 200 kg/m
2
, que acta sobre un rea
tributaria de 3 m por 6 m = 18 m en cada nivel de entrepiso.
Entonces, la fuerza no mayorada que acta en cada nivel de
entrepiso es de 3.6 T.

f
c
' = 281 kg/cm
2

f
y
de 4200 kg/cm
2


Debido a que las cargas laterales vienen de viento, las
combinaciones de carga relevantes son las

W L D U
W D U
6 . 1 6 . 1 2 . 1
6 . 1 9 . 0
+ + =
+ =


De estas dos, la combinacin que gobierna es la W D U 6 . 1 9 . 0 + = , pues la capacidad a flexin se
aumenta a medida que se aumente la carga axial.

Calcular las acciones en la base del muro.

T T V
u
3 . 17 6 . 3 3 6 . 1 = =

6 m
3 m
3 m
3 m
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


135
( ) m T m T M
u
= + + = 77 . 103 9 6 3 6 . 3 6 . 1


Carga muerta:

losa de 20 cm 500 kg/m
2

divisorios 100 kg/m
2

total 600 kg/m
2


( )( ) T m m kg P
u
44 . 19 6 / 600 9 . 0
2 2
= =


Usando el diagrama de interaccin para este muro (previamente derivado), podemos ver que la
combinacin de (M
u
, P
u
) cabe cmodamente dentro del diagrama, an tomando en cuenta los
factores de reduccin de capacidad. La capacidad en flexin es unos 6 veces mayor de lo que se
necesita, as que el nmero de niveles de la estructura podra incrementarse por un factor de 6 , es
decir, hasta unos 7 niveles.




0
500
1000
1500
2000
2500
3000
3500
4000
0 500 1000 1500 2000 2500 3000 3500 4000
P
n
,

T
Mn, T-m
Diagrama de Interaccion M-N para Muro Cortante
f'c=281 kg/cm2, 6.1 m de largo, 30 cm de espesor, 2 varillas de 12 mm en 30 cm
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


136

Ahora calcular la resistencia cortante:

T kg V
gobierna no kg pero kg
kg
de menor V
cm V
m m
cm
cm kg
cm cm
de menor V
d h f V pero d h
V
M
h
N
f
f
d N
d h f
de menor V
c
c
c
c
c c
w
w
c w
c
w
u
c
c
2 . 204 255 , 204
936 , 127 255 , 204
309 , 216
600 8 . 0 30 281 53 . 0 600 8 . 0 30
100
2
6
3 . 17
77 . 103
30 600
10 44 . 19
2 . 0 281 33 . 0 600
281 16 . 0
600 4
600 8 . 0 10 44 . 19
600 8 . 0 30 281 88 . 0
53 . 0
2
2 . 0 33 . 0
16 . 0
4
88 . 0
3
3
'
'
'
'
= =

>
=

>

|
.
|

\
|

|
|
.
|

\
|

+
+


+
=

>

|
.
|

\
|

|
|
.
|

\
|
+
+
+
=



An incluyendo el factor de disminucin de capacidad de 0.75 para corte, tenemos amplia capacidad.

El punto de arranque del diseo instantneo cumple fcilmente con los requisitos de diseo. Si
tenemos (por razones prescriptivas) que confinar el taln compresivo del muro, debemos ubicar el
eje neutro de la seccin bajo la carga axial indicada. Viendo el recorte de la hoja de clculo de
abajo, una fuerza axial de 19.44 T corresponde a una ubicacin del eje neutro de unos 35 cm. Hay
que proveerle confinamiento con razn volumtrica de alrededor de 0.01 en los ltimos 35 cm en los
dos extremos del muro. No hay necesidad de ponerle ms acero longitudinal en los extremos.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


137



6.7 Diseo de Muros Cortantes para Cargas Cclicas Alternas

El comportamiento de muros en este respecto es muy similar al de columnas. En general, tratamos
de:

o obtener buena ductilidad de curvatura; y

p disear para comportamiento dominado por flexin en lugar de corte.

Por cuanto el rea gruesa de muros de corte es grande, las fuerzas axiales estn muy abajo del punto
balanceado, y ductilidad adecuada de curvatura puede obtenerse

1) distribuyendo el acero a flexin uniformemente por la profundidad (largo en planta) del
muro; y

2) confinando aquellas regiones usando estribos cerrados, cercanamente colocados, para
aumentar la deformacin unitaria mxima del concreto, y demorar el pandeo del refuerzo
longitudinal.


Hoja de calculo para diagrama M-N para muro cortante
profundidad 609.6
ecu 0.003
f'c 281
beta1 0.85
fy 4200
Es 2.03E+06
d 563.88
(c/d)balanceado 0.591837
ancho 30
capas de acero se cuentan de la fibra extrema en compresion, hacia la varilla extrema en traccion
las distancias se miden de la fibra extrema en compresion
la compresion en concreto y refuerzo se toma como positiva
los esfuerzos en acero compresivo se ponen iguales a cero, pues el refuerzo no se apoya lateralmente
Capa de Refuerzo distancia Area
1 45.72 7.74
2 137.20 7.74
3 228.60 7.74
4 304.80 5.16
5 381.00 7.74
6 472.40 7.74
7 563.90 7.74
c/d c Cconc fs(1) fs(2) fs(3) fs(4) fs(5) fs(6) fs(7) Momentouerza Axia
compresion pura 0 3702
puntos controlados por concreto 1.08 608.99 3709163 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1705 3709
0.9 507.49 3090969 0.00 0.00 0.00 0.00 0.00 0.00 -676.91 2768 3086
0.8 451.10 2747528 0.00 0.00 0.00 0.00 0.00 -287.50 -1522.77 3141 2734
0.7 394.72 2404087 0.00 0.00 0.00 0.00 0.00 -1198.57 -2610.31 3363 2375
0.591837 333.72 2032610 0.00 0.00 0.00 0.00 -862.70 -2530.62 -4200.00 3435 1974
puntos controlados por acero 0.591837 333.72 2032610 0.00 0.00 0.00 0.00 -862.70 -2530.62 -4200.00 3435 1974
0.5 281.94 1717205 0.00 0.00 0.00 -493.78 -2139.73 -4114.00 -4200.00 3327 1634
0.4 225.55 1373764 0.00 0.00 -82.30 -2139.73 -4197.16 -4200.00 -4200.00 3033 1265
0.3 169.16 1030323 0.00 0.00 -2139.73 -4200.00 -4200.00 -4200.00 -4200.00 2551 895
0.2 112.78 686882 0.00 -1318.92 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 1886 525
0.063 35.52 216368 -1747.84 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 676 19
0.01 5.64 34344 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 104 -182
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


138
Al igual que para las columnas, hasta una respuesta dominada por flexin eventualmente se limita
por una falla cortante deslizante, despus de ciclos alternos repetidos. Para demorar ese tipo de falla,
debemos disear el muro de modo que :

1) el agrietamiento inclinado no ocurra, an bajo los momentos ms grandes producibles en el
muro;

2) despus del agrietamiento diagonal (si esto ocurre), toda la capacidad cortante necesaria
pueda proveerse por el refuerzo (mecanismo de puntales y tensores); y

3) el esfuerzo cortante nominal se mantenga suficientemente bajo para demorar la falla cortante
deslizante, y por aplastamiento diagonal del alma.

Refirindonos al planteamiento anterior sobre columnas, podemos ver que los primeros dos
requisitos son equivalentes a que tanto el diagrama M-N controlado por V
c
, como el diagrama M-N
controlado por V
s
, estn fuera del diagrama M-N controlado por flexin.



En este caso, sin embargo, el enfoque no es tan sencillo como para una columna, pues un muro no
tiene rtulas plsticas en los extremos de una columna al nivel de un piso. La relacin entre los
valores de M y V aplicados al muro depende de la distribucin de carga sobre un muro aislado, y de
las rigideces relativas del muro y prtico si el muro forma parte de un sistema combinado. No
obstante, los requisitos pueden ilustrarse por el ejemplo abajo:



Hay que disear el muro por las cargas dadas, de modo que en el valor de P
u
,

( )
n n u u
P M P M , ) ( o s

Pero si la carga mxima viene de sismo, es muy difcil predecir. Tenemos el rompecabezas de tener
que prevenir una falla cortante, cuando no sabemos el corte mximo.
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


139

Podemos resolver el rompecabezas mediante el enfoque de diseo por capacidad. Tenemos que
disear el muro de modo que su resistencia al corte sea mayor que el mayor corte correspondiente a
la formacin de un mecanismo plstico a flexin en el muro.

Procediendo de la izquierda a la derecha en la figura de arriba, consideremos una sobrecarga,
indicada por la lnea punteada. Suponiendo la misma distribucin de carga lateral a lo alto del muro,
esta corresponde a una distribucin de corte que se indica en la figura en medio, y una
correspondiente distribucin de momento que se indica en la figura derecha. El valor mximo de
momento se limita solamente por la capacidad a flexin del muro, la cual puede ser tan alta como
oM
n
, donde el factor o representa un aumento en la capacidad a flexin debido a una combinacin
de sobre-resistencia del acero (sobre el valor especificado de cedencia), y endurecimiento por
deformacin inelstica. Al igual que para las conexiones viga-columna, o puede tener un valor de
unos 1.25.

Entonces, tenemos que requerir que

( )
( )
u
n
u n
n n
M
M
V V
M V V
o
o
o o
>
>


1) ( )
n c
M V V o o > ; y

2) ( )
n s
M V V o o >


Observaciones:

1) Entre mayor sea la razn (M
u
/V
u
) para un muro, ms fcil ser disearlo para
comportamiento gobernado por flexin.

2) Si la razn (M
u
/V
u
) es pequea, resulta muy difcil disear el muro para comportamiento
gobernado por flexin. En tal caso, es mejor disear el muro para permanecer elstico bajo
las ms grandes cargas anticipadas.

3) Estudios experimentales han demostrado que la falla del muro falla por corte deslizante
puede demorarse si el esfuerzo cortante nominal.

'
6 . 1
c
n
n
f
d h
V
v s =

Este requisito normalmente es menos severo que el requisito que ( )
n c
M V V o o > .


6.8 Interaccin Muro-Prtico
Los muros altos se usan a menudo con prticos. Bajo cargas laterales, los patrones de
desplazamientos laterales del muro y del prtico son distintos. El requisito de compatibilidad de
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


140
desplazamientos horizontales entre muro y prtico en cada piso da lugar a fuerzas de interaccin
entre los dos. Por lo tanto, los diagramas de momentos y cortes para el muro, son significativamente
diferentes a los correspondientes a un muro aislado, semejantemente cargado.

Ahora conectar prtico y muro:



Como resultado, tenemos las siguientes acciones en el muro:


Notar que las fuerzas de interacci6n muro-prtico tienden a reducir los momentos mximos, pero a la
vez aumentar los cortes, y a reducir la razn (M/Vd). Esto aumenta la tendencia a una falla cortante.
Al disear tales muros para buenas caractersticas de disipacin de energa, es importante disear
para que:

1) ( )
n c
M V V o o > ; y

2) ( )
n s
M V V o o >

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


141
Para una capacidad a flexin dada, el corte producible en tal tipo de muro a lo mejor es mayor que el
corte aislado con igual capacidad a flexin.


6.9 Muros Acoplados
Una desventaja potencial de muros aislados a flexin, es que una disipacin significativa de energa
puede ocurrir slo a travs de la cedencia a flexin del muro, la cual involucra el peligro de deterioro
de la regin crtica en la base del muro. Este tipo de dao es difcil de reparar, pues el muro
normalmente resiste la mayora de las cargas verticales del edificio.

6.9.1 Comportamiento de Muros Acoplados

Consideremos la respuesta de dos muros a flexin, acoplados por vigas relativamente cortas:



Las deformaciones a flexin de los muros causan grandes desplazamientos relativos entre los
extremos de las vigas de acople. Mientras mayor sea la rigidez de estas vigas, mayor ser la rigidez
del sistema conjunto. Vigas muy flexibles producen un comportamiento semejante al de dos muros
aislados, mientras que vigas rgidas producen un comportamiento semejante al de una seccin
integral.

Sin embargo, la ventaja principal del sistema de muros acoplados, es su respuesta inelstica. Grandes
desplazamientos relativos entre los extremos de las vigas provocan la formacin de rtulas plsticas
en las vigas, mucho antes de la formacin de rtulas en los muros mismos. La estructura puede
disipar mucha energa slo por fluencia de las vigas de acople. Si estas vigas se daan severamente,
pueden repararse con relativa facilidad, sin poner al edificio fuera de servicio. Si las vigas estn
completamente destruidas an, el edificio tiene la otra lnea de defensa ofrecida por la resistencia de
los muros, actuando en forma independiente.
.
El diseo de muros acoplados involucra dos requisitos :

1) El sistema debe desarrollar rtulas plsticas en las vigas, antes de la ocurrencia de falla por
corte, o de rtulas significativas en los muros; y

2) Las vigas acopladas deben exhibir buena disipacin de energa bajo ciclos repetidos de carga
alterna.

Con vistas a cumplir el primer requisito, examinemos la distribucin de fuerzas internas en los muros
cuando algunas vigas se han cedido:

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


142



El efecto principal de la formacin de rtulas en las vigas acopladoras es la reduccin de fuerza axial
en un muro. Si el corte en cada viga cedida es

viga
viga p
L
M
V
2
=

la carga axial en la base de este muro podra reducirse por el producto de
|
|
.
|

\
|
viga
viga p
L
M 2
por el nmero
de pisos, suponiendo que rtulas plsticas se forman simultneamente en todas las vigas. En la
realidad, algunas vigas no habrn cedido, y otras estarn en el rango del endurecimiento, dando una
reduccin un poco menor, de unos 0.90 por
|
|
.
|

\
|
viga
viga p
L
M 2
por el nmero de pisos.

Esta reduccin en carga axial trae una consecuente reduccin en la resistencia a corte del muro
afectado, particularmente si la carga neta es de traccin. Para evitar una falla cortante en tal
circunstancias, hay que disear los muros de modo que

1) ( )
n c
M V V o o > ; y

2) ( )
n s
M V V o o >


6.9.2 Detallado de Vigas Acopladoras

En cuanto al segundo requisito, examinemos las demandas de disipacin de energa a las vigas
acopladoras:

1) Deben soportar ciclos repetidos de carga alterna, a rotaciones plsticas muy grandes; y

2) Muchas veces tienen razones muy bajas de luz de corte (a/d < 2). El segundo punto es
crtico. Hemos visto que es casi imposible evitar la degradacin rpida por corte en
miembros con tales proporciones.

Para evitar tales dificultades, hay que usar detalles especiales de refuerzo en las vigas acopladoras:
en adicin a algn refuerzo ordinario a flexin, usamos refuerzo diagonal.
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


143





Tales vigas diagonalmente reforzadas, pueden producir sistemas acoplados con caractersticas de
disipacin de energa, realmente excelentes.



:
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


144

7. COMPORTAMIENTO Y DISEO DE LOSAS DE CONCRETO REFORZADO

7.1 Introduccin al Diseo de Losas
La mayora de edificios de concreto reforzado tienen losas de concreto reforzado tambin. Estas
losas consisten en dos componentes:

1) paneles; y

2) regiones viga.

Las regiones viga pueden tener la forma de vigas visibles en el lado inferior de la losa (losas con
vigas), o la forma de vigas embebidas dentro de la losa (losas planas). Sea cual sea la forma de las
vigas, su funcin es idntica. El flujo de fuerzas, por el cual tenemos que disear, es del panel a las
regiones viga, y de stas a las columnas.




En un edificio sujeto a carga ssmica, las losas tienen que resistir momentos debidos a cargas
laterales, en adicin a los que vienen de cargas verticales. Si las losas tienen vigas entre las
columnas, la resistencia a flexin de ellas es grande, y pueden comportarse bien. En cambio, si las
losas no tienen vigas (es decir, si son losas planas), tienen poca resistencia.

Adems, el taln de Aquiles de las losas planas, es su sensibilidad a falla por punzonamiento y por
transferencia de momentos alrededor de las columnas. Los momentos a transferirse pueden ser muy
grandes, del orden de la sumatoria de las capacidades en flexin, de las regiones tipo viga que se
apoyan en las columnas. Toda losa plana debe disearse usando las provisiones por transferencia de
momentos (por ejemplo, de la Seccin 11.10 del ACI 318-08).


Los enfoques de diseo a flexin de las losas incluyen los siguientes:

1) El mtodo de franjas (Hillerborg 1959, traducido de dans al ingls en 1975). Este es el
mtodo ms sencillo y directo de disear losas, sea cual sea la forma de sus vigas. El panel
se disea como un ensamblaje de franjas independientes en las dos direcciones, con la
porcin de la carga total resistida en cada direccin, al gusto del diseador. Las franjas en
cada direccin se apoyan sobre las regiones viga, las cuales tienen que disearse por las
reacciones de las franjas. Las regiones viga se apoyan sobre las columnas. Adems de ser
regiones viga
panel
columnas
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


145
simple, este mtodo es seguro, pues constituye un mtodo al lmite inferior, porque
satisface el equilibrio y las relaciones constitutivas, pero no necesariamente la cinemtica.
Cualquier capacidad calculada con base a este mtodo es menor o igual a la capacidad real, y
por lo tanto el mtodo es inherentemente seguro para diseo. Es un ejemplo del enfoque
general de proveerle a la estructura un camino para la transmisin de fuerzas de su punto de
aplicacin a la cimentacin; y de proveerle a ese camino suficiente capacidad de resistir las
acciones, consistentes con las deformaciones que se experimentan a lo largo del camino.
Vamos a estudiar el mtodo de franjas en este curso.

2) El mtodo de lneas de cedencia. Este mtodo es el anlogo, en dos dimensiones, al mtodo
plstico de anlisis de vigas. El paso clave en el mtodo consiste en proponer un mecanismo
de colapso de la losa, mediante lneas de cedencia que son anlogas (en dos dimensiones) a
rtulas plsticas. Se calcula la capacidad a flexin a lo largo de las lneas de cedencia.
Mediante el trabajo virtual, se calcula la capacidad a flexin correspondiente al colapso bajo
las cargas dadas. Este mtodo es seductora pero ltimamente peligrosa, pues constituye un
mtodo al lmite superior, porque satisface la cinemtica y el equilibrio, pero no
necesariamente las relaciones constitutivas (el momento de cedencia puede excederse fuera
de alguna lnea de cedencia). Cualquier capacidad calculada con base a este mtodo es
mayor o igual a la capacidad real, y por lo tanto el mtodo es inherentemente no seguro para
diseo. Por este defecto fatal, no vamos a tratar ms el mtodo de lneas de cedencia en este
curso.

3) El enfoque del prtico equivalente (ACI), el cual se expresa o en el mtodo directo de diseo
(coeficientes), o en el mtodo del prtico equivalente. Este mtodo fue desarrollado en los
aos 60 para mejorar los enfoques previos del ACI. Ms o menos satisface el equilibrio, as
que es ms o menos seguro. Sin embargo, es mucho ms complejo que el mtodo de franjas.
Adems, el mtodo de diseo directo slo admite cargas uniformemente distribuidas. Por
estas debilidades, no vamos a tratar ms el enfoque del prtico equivalente en este curso.

4) Anlisis a elementos finitos, integrando los esfuerzos calculados para obtener momentos de
diseo. Este enfoque es seguro, pues satisface la cinemtica, las relaciones constitutivas, y
el equilibrio. Sin embargo, es innecesariamente complejo, y adems potencialmente
equivocado despus del agrietamiento del concreto (por flexin) en la losa. Por estas
debilidades, no vamos a tratar ms el enfoque del prtico equivalente en este curso.


7.2 Antecedentes sobre el Mtodo de Franjas

Independiente de si una losa se comporta elsticamente o no,
equilibrio requiere que

q
y
m
y x
m
x
m
y xy
x
=
c
c
+
c c
c
+
c
c
2
2 2
2
2
2


Notar que m
x
es el vector de momentos perpendiculares al
eje x, y que m
y
es el vector de momentos perpendiculares al
eje y. Esta nomenclatura es tpica para losas. Los momentos
m
xy
son momentos torsores (momentos de alabeo).
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


146

Digamos que suponemos, conservadoramente, que los momentos de alabeo son cero. Entonces
tenemos q
y
m
x
m
y
x
=
c
c
+
c
c
2
2
2
2
, la cual puede dividirse en dos partes,
x
x
q
x
m
=
c
c
2
2
y
y
y
q
y
m
=
c
c
2
2
, donde
y x
q q q + = .


7.3 Aplicacin del Mtodo de Franjas
Al aplicar el mtodo de franjas, el panel de losa se idealiza como dos juegos de franja tipo viga,
orientados paralelos a los ejes x e y:



Las franjas x resisten los m
x
. Las franjas y resisten los m
y
.

Cada rea unitaria de la losa se cruza por una franja x y una franja y. La carga en aquella rea se
reparte entre las dos franjas segn el juicio del diseador. Una vez hecho esto, se saben las cargas en
cada franja x y cada franja y. Entonces se disean las franjas como vigas para aquellas cargas. Las
condiciones de apoyo estn tambin al juicio del diseador, pero pueden depender de si la losa tiene
continuidad por la regin viga, o termina all.


b
a
f ranjas x f ranjas y
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


147

Ejemplo: Calcular los momentos de diseo para una losa cuadrada, simplemente apoyada, con una
carga uniforme q
u
.


Suponer que la carga uniforme se distribuye igualmente a los
dos juegos de franjas, no obstante la ubicacin sobre la losa.
Entonces cada juego de franjas resiste carga uniforme de q
u
/2.










16 8 2
2 2
a q a q
m
u u
x
= =

(m alrededor del eje y)
(m a escuadras del Corte A-A)








(m alrededor del eje y)
(m a lo largo de una franja x)



Ahora completar el diseo con las regiones viga, las cuales tienen que soportar las franjas x e y.

Las franjas x producen reacciones |
.
|

\
|
= |
.
|

\
|
|
.
|

\
|
4 2 2
a q a q
u u
por unidad de largo de cada regin viga.


regiones viga
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


148

El momento mximo en las regiones viga es
32 8 4
3 2
a q a a q
u u
=
|
|
.
|

\
|
|
.
|

\
|
.


Ahora revisar el equilibrio global del panel ms las regiones viga:




bien
a q a q a q
a
a q a q a a q
M
u u u
u u u
referencia eje
16 16 8
16 32
2
4 2
0
3 3 3
2 3 2
+ =
+
|
|
.
|

\
|
= |
.
|

\
|
|
|
.
|

\
|
=



Los momentos de diseo satisfacen el equilibrio.


a
eje de ref erencia
a/2
momento region viga momento region viga
momento panel
|
.
|

\
|
2
a
a q
u
32
3
a q
u
32
3
a q
u
16
2
a q
u
por unidad de largo
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


149

7.4 Ejemplos de Diseo, Mtodo de Franjas
Este juego de ejemplos trata una losa plana, un panel tpico del cual se muestra abajo. La distancia
entre ejes de columnas es 6 m; las columnas cuadradas miden 60 cm; la losa tiene espesor de 20 cm; y
la resistencia especificada del concreto es 281 kg/cm2; y la resistencia especificada del refuerzo es
4200 kg/cm2. La losa tiene una carga mayorada, uniformemente distribuida, de 1.0 T/m2 (incluye
peso propio).




7.4.1 Ejemplo de Diseo, Losa de Una Sola Direccin

Usando el mtodo de franjas, disear la losa como una losa de una sola direccin. No es la suposicin
ms realista, pero s sirve para demostrar el mtodo. Suponer que las cargas se resisten dentro del
panel por franjas orientadas horizontalmente en el papel. Mostrar las capacidades requeridas dentro del
panel, y en las regiones viga. Usar regiones viga con ancho de 1.2 m (el doble de la dimensin de las
columnas, y 60 cm de ancho en cada lado de los ejes de columna). Suponer momentos negativos y
positivos iguales. Mostrar la colocacin requerida de refuerzo a flexin en un panel tpico, y en las
medias regiones viga que estn dentro de los bordes del panel. Suponer un peralte efectivo de 16.9 cm,
y un brazo interno del 90% de ese valor, o 15.2 cm.

Al disear esta losa para que toda la carga se resista por las franjas orientadas horizontalmente en la
pgina, el momento esttico total es:

cm kg m T
m m T q
M
u
o
= =

= =
5
3 3 2 3
10 27 27
8
6 / 1
8

,

Suponer que la mitad de esto es positivo y la otra mitad negativo, as que el panel tiene que disearse
por una capacidad negativa y positiva de 13.5 x 10
5
kg-cm, distribuida a lo largo de 6 m. La capacidad
resultante por metro de losa es 225,000 kg-cm, dividida por el factor o de 0.9, o 250,000 kg-cm. El
rea requerida de refuerzo a flexin por metro de ancho es

6 m entre ejes (tipico)
columnas cuadradas de 60 cm
f
c
= 281 kg/cm2
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


150
2
2
52 . 3
/ 4200 2 . 15
000 , 225
cm
cm kg cm
cm kg
f brazo
M
A
y
s
=

=

Suponer un espacio entre varillas de 30 cm. El rea requerida de cada varilla es 0.30 por 3.52 cm
2
, o
1.06 cm
2
. Usar varillas de 12 mm en 30 cm arriba y abajo, orientadas horizontalmente en la pgina.

Esto tambin satisface los requisitos del ACI 318-08 para refuerzo mnimo por retraccin y
temperatura:

2 2
min
13 . 1 08 . 1 20 30 0018 . 0 0018 . 0 cm cm cm cm t b A
s
s = = =

Ahora disear las regiones viga. Por cuanto las franjas en el panel se orientan horizontalmente en la
pgina, no se necesitan regiones viga es esa direccin. Verticalmente en la pgina, las regiones viga
tienen que soportar las reacciones de las franjas horizontalmente orientadas. Cada media regin viga
tiene un ancho tributario de 3 m, y una carga correspondiente uniformemente distribuida de 3 T/m. El
momento esttico total para cada media regin viga es

m T
m m T w
M
u
viga o
=

= = 5 . 13
8
6 / 3
8
2 2 2



Al suponer momentos negativos iguales a los positivos, la capacidad mxima de cada media regin
viga tiene que ser 6.75 T-m, dividida por el factor o de 0.90, o 7.50 T-m. El rea requerida de refuerzo
a flexin arriba y abajo tiene que ser

2
2
5
75 . 11
/ 4200 2 . 15
10 50 . 7
cm
cm kg cm
m T
cm kg
m T
f brazo
M
A
y
requerido
n
s
=

|
.
|

\
|

=

Usar 4 varillas de 19 mm arriba y abajo. Abajo se muestra el refuerzo final a flexin. Desde luego,
habra sido posible combinar el refuerzo del panel y de la regin viga en los bordes. El refuerzo ha
sido mantenido en forma separada para propsitos docentes. En la direccin vertical de la pgina,
habra que poner refuerzo mnimo por retraccin y temperatura.


varillas 12 mm en 30 cm
arriba y abajo
4 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
4 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


151


7.4.2 Ejemplo de Diseo, Losa de Dos Direcciones

Repetir el ejemplo anterior, ahora suponiendo que las cargas se resisten igualmente por franjas
orientadas horizontal y verticalmente en la pgina.

Al disear esta losa de modo que la carga se resiste igualmente por franjas orientadas horizontal y
verticalmente en la pgina, el momento esttico total en cada juego de franjas de panel es

m T
m m T q
M
u
o
=

= 5 . 13
8
6 / 5 . 0
8 2
3 3 2 3

,

Suponer que la mitad de esto es positivo y la otra mitad negativo, de modo que cada juego de franjas de
panel tiene que disearse por una capacidad a flexin de 6.75 T-m, distribuida sobre 6 m. La resultante
capacidad por metro de ancho, dividida por el factor o de 0.90, es 1.25 T-m. El rea requerida de
refuerzo a flexin por metro de ancho es

2
2
5
96 . 1
/ 4200 2 . 15
10
25 . 1
cm
cm kg cm
m T
cm kg
m T
f brazo
M
A
y
s
=

|
|
.
|

\
|

=

Suponer un espacio entre varillas de 30 cm. El rea requerida de cada varilla es 0.30 por 1.96 cm
2
, o
0.59 cm
2
. Usar varillas de 12 mm en 30 cm arriba y abajo, orientadas horizontal y verticalmente en la
pgina.

Esto tambin satisface los requisitos del ACI 318-08 para refuerzo mnimo por retraccin y
temperatura:

2 2
min
13 . 1 08 . 1 20 30 0018 . 0 0018 . 0 cm cm cm cm t b A
s
s = = =

Habra sido posible usar varillas de menor dimetro. Las varillas de 12 mm han sido retenidas para
enfatizar que la capacidad a flexin en cada direccin dentro del panel es la mitad de la capacidad
requerida en la losa de una direccin del ejemplo anterior. Es de notarse tambin que al igual que el
ejemplo anterior, los requisitos de refuerzo mnimo por retraccin y temperatura gobiernan.

Ahora disear las regiones viga. Puesto que igual carga se resisten por las franjas de panel orientadas
horizontal y verticalmente, la capacidad requerida de las regiones viga es la misma en cada direccin.
Cada regin viga tiene que soportar las reacciones de las franjas de panel. Cada media regin viga
tiene ancho tributario de 3 m, y en consecuencia una carga uniformemente distribuida de 1.5 T/m. El
momento esttico total para cada media regin viga es

m T
m m T w
M
u
viga o
=

= = 75 . 6
8
6 / 5 . 1
8
2 2 2



Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


152
Suponiendo iguales momentos positivos y negativos, la capacidad mxima a flexin de cada media
regin viga tiene que ser 3.38 T-m, dividida por el factor o de 0.90, o 3.75 T-m. El rea requerida de
refuerzo a flexin, arriba y abajo, es

2
2
5
. 87 . 5
/ 4200 2 . 15
10
75 . 3
in
cm kg cm
m T
cm kg
m T
f brazo
M
A
y
s
=

|
|
.
|

\
|

=

Usar 2 varillas de 19 mm arriba y abajo. Abajo se muestra el refuerzo final a flexin. Desde luego,
habra sido posible combinar el refuerzo del panel y de la regin viga en los bordes. El refuerzo ha
sido mantenido en forma separada para propsitos docentes.



Es de notarse que el refuerzo dentro del panel se gobierna por requisitos de retraccin y temperatura, y
que la cantidad total de refuerzo en las regiones viga es igual en los dos ejemplos.



varillas 12 mm en 30 cm
arriba y abajo, dos sentidos
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


153

8. PROYECTO DEL DISEO SSMICO EN CONCRETO REFORZADO

8.1 Introduccin al Diseo Preliminar
Este curso concluye con un proyecto del diseo ssmico preliminar de un edificio de 8 pisos en
concreto reforzado. En un sentido, el diseo es superfluo, pues es esencialmente la combinacin de
los ejemplos del diseo instantneo de cada captulo anterior de los apuntes.

Sin embargo, agrega la relacin entre cada faceta del diseo, y adems enfatiza el papel fundamental
del enfoque del lmite inferior. Con tal de proveerle un camino adecuado para la transmisin de
fuerzas, la estructura estar segura. En este caso,

o Comenzamos con un clculo genrico de las fuerzas de diseo, incluyendo de diseo
ssmico.

o Seguimos con el diseo de los elementos de entrepiso. El espesor de la losa se gobierna por
deflexiones y por transferencia de momentos y cortes alrededor de las columnas. El
detallado de las vigas o regiones viga se conforma al diseo instantneo.

o Las dimensiones y refuerzo preliminar de las columnas se gobiernan por cargas de gravedad.

o Los muros se disean para toda la carga lateral. Este enfoque es inherentemente seguro,
pues conforma al teorema del lmite inferior. Se suman las capacidades del ncleo y de los
muros perimetrales, sin considerar sus rigideces relativas.

o Finalmente, se comenta sobre la relacin entre las facetas de diseo preliminar, y sobre
posibles refinamientos al diseo preliminar.


8.2 Introduccin al Edificio del Diseo Preliminar
El edificio del diseo preliminar
es de 8 niveles, con la planta
tpica que se muestra a la
derecha. La altura de cada piso
es de 3 m. Por deflexiones y
transferencia de momentos y
cortes entre losa y columnas, la
losa plana tiene espesor de 20
cm. Las columnas cuadradas
tienen dimensiones de unos 60
cm. Los muros del ncleo
tienen espesor de 30 cm, y dos
capas de varillas de 12 mm en
30 cm horizontal y
verticalmente. El ncleo se
complementa por muros
perimetrales de 6 m de largo en
6 m tipico
nucleo
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


154
planta cada uno. Los muros perimetrales tambin tienen espesor de 30 cm, y dos capas de varillas de
12 mm en 30 cm horizontal y verticalmente.


8.3 Clculo Preliminar de Acciones de Diseo
Las acciones de diseo incluyen cargas de gravedad y cargas ssmicas.

8.3.1 Clculo de Cargas de Gravedad

Con base en el ejemplo de la Seccin 2.10, tenemos las cargas siguientes:


Carga muerta:

losa de 20 cm 500 kg/m
2

divisorios 100 kg/m
2


total

600 kg/m
2



Carga viva:

250 kg/m
2
, reducida por rea tributaria 200 kg/m
2



El peso total de la estructura es:

Peso de 8 entrepisos: 8 x 30 x 30 m
2
x 0.6 T/m
2
= 4320 T


Verticalmente, el rea tributaria del ncleo es cuadrada, y mide un vano ms dos medios vanos en
cada lado, es decir, 12 m en cada lado. Suponiendo que el ncleo resiste carga vertical segn su rea
tributaria, la carga axial debido a carga muerta es de

T
m
m
T a C 2 . 691
30
12
4320 arg
2 2
2 2
=
|
|
.
|

\
|
=



8.3.2 Clculo del Coeficiente Ssmico de Diseo

Digamos que estamos en una zona de alto riesgo ssmico, con ordenadas espectrales de 1.0 g
(correspondiente a la plataforma del espectro). Digamos que el sistema estructura es uno de muros
especiales de concreto reforzado, con un factor de reduccin R de fuerzas ssmicas igual a 5. El
coeficiente ssmico global es de

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


155
20 . 0
5
0 . 1
=



8.3.3 Clculo de Acciones Ssmicas de Diseo

El corte se calcula suponiendo un reparto lineal de las fuerzas a lo alto de la estructura. Puesto que
cada nivel tiene peso igual, el peso mismo no influye en el reparto.


Piso W H WH WH/SUM
Techo 540 24 0.222
7 540 21 0.194
6 540 18 0.167
5 540 15 0.139
4 540 12 0.111
3 540 9 0.0833
2 540 6 0.0556
PB 540 3 0.0278
108 0.9997



El corte basal es 4320 T x 0.20 = 864 T. Los cortes y momentos en cada nivel se calculan abajo:

Piso W H WH/SUM F
piso
, T V, T M, T-m
Techo 540 24 0.222 191.8 191.8 0
7 540 21 0.194 167.6 359.4 575
6 540 18 0.167 144.3 503.7 1654
5 540 15 0.139 120.1 623.8 3165
4 540 12 0.111 95.9 719.7 5036
3 540 9 0.0833 72.0 791.7 7195
2 540 6 0.0556 48.0 839.7 9570
PB 540 3 0.0278 24.0 863.7 12089
Base 14681


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


156

Los diagramas de corte y de momento se muestran abajo.




8.4 Diseo Preliminar de Losa y Vigas
Este ejemplo es idntico al ejemplo de la Seccin 7.4.2. Suponer un peralte efectivo de 16.9 cm, y un
brazo interno del 90% de ese valor, o 15.2 cm.

Al disear esta losa de modo que la carga se resiste igualmente por franjas orientadas horizontal y
verticalmente en la pgina, el momento esttico total en cada juego de franjas de panel es

m T
m m T q
M
u
o
=

= 5 . 13
8
6 / 5 . 0
8 2
3 3 2 3

,

Suponer que la mitad de esto es positivo y la otra mitad negativo, de modo que cada juego de franjas de
panel tiene que disearse por una capacidad a flexin de 6.75 T-m, distribuida sobre 6 m. La resultante
capacidad por metro de ancho, dividida por el factor o de 0.90, es 1.25 T-m. El rea requerida de
refuerzo a flexin por metro de ancho es

2
2
5
96 . 1
/ 4200 2 . 15
10
25 . 1
cm
cm kg cm
m T
cm kg
m T
f brazo
M
A
y
s
=

|
|
.
|

\
|

=

Suponer un espacio entre varillas de 30 cm. El rea requerida de cada varilla es 0.30 por 1.96 cm
2
, o
0.59 cm
2
. Usar varillas de 12 mm en 30 cm arriba y abajo, orientadas horizontal y verticalmente en la
pgina.

192
720
792
840
0
V , T
M , T-m
359
504
624
864
1654
3165
5036
7195
575
9570
12089
14681
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


157
Esto tambin satisface los requisitos del ACI 318-08 para refuerzo mnimo por retraccin y
temperatura:

2 2
min
13 . 1 08 . 1 20 30 0018 . 0 0018 . 0 cm cm cm cm t b A
s
s = = =

Habra sido posible usar varillas de menor dimetro. Las varillas de 12 mm han sido retenidas para
enfatizar que la capacidad a flexin en cada direccin dentro del panel es la mitad de la capacidad
requerida en la losa de una direccin del ejemplo anterior. Es de notarse tambin que al igual que el
ejemplo anterior, los requisitos de refuerzo mnimo por retraccin y temperatura gobiernan.

Ahora disear las regiones viga. Puesto que igual carga se resisten por las franjas de panel orientadas
horizontal y verticalmente, la capacidad requerida de las regiones viga es la misma en cada direccin.
Cada regin viga tiene que soportar las reacciones de las franjas de panel. Cada media regin viga
tiene ancho tributario de 3 m, y en consecuencia una carga uniformemente distribuida de 1.5 T/m. El
momento esttico total para cada media regin viga es

m T
m m T w
M
u
viga o
=

= = 75 . 6
8
6 / 5 . 1
8
2 2 2



Suponiendo iguales momentos positivos y negativos, la capacidad mxima a flexin de cada media
regin viga tiene que ser 3.38 T-m, dividida por el factor o de 0.90, o 3.75 T-m. El rea requerida de
refuerzo a flexin, arriba y abajo, es

2
2
5
. 87 . 5
/ 4200 2 . 15
10
75 . 3
in
cm kg cm
m T
cm kg
m T
f brazo
M
A
y
s
=

|
|
.
|

\
|

=

Usar 2 varillas de 19 mm arriba y abajo. Abajo se muestra el refuerzo final a flexin. Desde luego,
habra sido posible combinar el refuerzo del panel y de la regin viga en los bordes. El refuerzo ha
sido mantenido en forma separada para propsitos docentes.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


158


Es de notarse que el refuerzo dentro del panel se gobierna por requisitos de retraccin y temperatura, y
que la cantidad total de refuerzo en las regiones viga es igual en los dos ejemplos.


8.5 Diseo Preliminar de Columnas

Este ejemplo sigue los pasos del ejemplo de Seccin 3.11.

Los fundamentos del comportamiento de columnas de concreto reforzado expresados en esta
seccin, pueden encapsularse en unos procedimientos generales de diseo de tales columnas:

Usar las mismas cargas de antes, con un rea tributaria de 36 m
2
.

Carga muerta:

losa de 20 cm 500 kg/m
2

divisorios 100 kg/m
2

total 600 kg/m
2


Carga viva:

250 kg/m
2
, reducida por rea tributaria
(mltiples pisos)
100 kg/m
2



( ) ( )
2 2 2 2
/ 88 . 0 / 880 / 100 6 . 1 / 600 2 . 1 m T m kg m kg m kg q
u
~ = + =

varillas 12 mm en 30 cm
arriba y abajo, dos sentidos
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
2 varillas de 19 mm arriba
y abajo dentro de 0.6 m
del borde
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


159
Para contar el peso propio de las columnas, usar 1.0 T/m
2
.

( ) ) ( 36 6 / 0 . 1
2 2
T n n m m T P
u
= =

Disear la columna para estar bajo el punto balanceado, con refuerzo del 2% y f
c
' de 420 kg/cm
2
.

3
0
P
P y
P
P
P P
n
u
n
n u
~ >
s
o
o


o
u
P
P
3
0
=

Suponer que o = 0.75 (entre o = 0.65 y o = 0.90).

y g g g c
f A A f P p + =
'
0
85 . 0


Usar f
c
' = 420 kg/cm
2
y p
g
= 0.02.

( ) ( )
o
u
g g g g
P
T A kg A A A P
3
441 . 0 441 4200 02 . 0 420 85 . 0
0
~ = = + =


( )
2
327
75 . 0 441 . 0
36 3
441 . 0
3
cm n
n P
A
u
g
=

= =
o



n (pisos) A
g
(cm
2
) Dimensiones (cm) Refuerzo
(p
g
= 0.02)
5 1635 40 x 40 8 de 22 mm
10 3270 60 x 60 8 de 32 mm
15 4905 70 x 70 12 de 32 mm


Usar columnas de 60 por
60, con 8 varillas de 32
mm. Usar amarres y
amarres suplementarios
en 10 cm.


8 varillas de 32 mm
acero de 4200 kg/cm2
recubrimiento = 4 cm
f
c
= 420 kg/cm2
amarres de 12 mm
60 cm
60 cm
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


160

8.6 Diseo Preliminar de Conexiones Viga-Columna

Estos ejemplos siguen los patrones de los diseos de las Secciones 4.2.4 y 4.3.3, pues tenemos un
prtico especial. Suponer un peralte efectivo de 20 cm 2 cm 1 cm = 17 cm. En una conexin
tpica, tenemos un total de 4 varillas de 19 mm arriba y abajo, separadas en una distancia de 14 cm.


8.6.1 Diseo Preliminar de Una Conexin Viga-Columna Interior

Tenemos que disear la conexin por corte, por anclaje, y por confinamiento.


Diseo por Corte:

****

Tenernos que calcular primero el corte en las columnas. Supongamos que existen puntos de inflexin
en la mitad de cada columna. Los pisos tienen altura de 3m.



Usar

( )
( )
T
cm
cm T
V
cm T cm cm kg cm M M
d d f A M
col
y s n
45 . 4
300
9 . 666 2
9 . 666 14 / 4200 9 . 1
4
4
2 2
2 1
'
=

=
= = =
~
t



( )
( )
T V
T T T cm kg V
V f A A V
conexion
conexion
columna y s s conexion
6 . 114
45 . 4 1 . 119 45 . 4 / 4200 25 . 1 34 . 11 34 . 11
2
2 1
=
= + =
+ = o


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


161


Calcular la capacidad cortante de la conexin por

T
T V
V
A v V
u requerido
n
conexion conexion n
9 . 134
85 . 0
6 . 114
= = =
=
o


Suponiendo vigas confinantes en los cuatro lados de la conexin,

conexion c n
A f V
'
22 . 5 =

El rea efectiva de la conexin se define en la Seccin 21.7.4.1 del ACI 318-08:

+
+
=
x b
h b
h A
col j
2
min




En nuestro caso, el ( )
col
b x b = + 2 gobierna.

( ) Bien V T kg cm V
requerido
n n
> = = = 385 121 , 385 60 420 22 . 5
2



Diseo por Anclaje:

Ahora revisar el anclaje. Por cuanto no hay varillas terminadas dentro de la conexin, no hay
requisitos. Sin embargo, la Seccin 21.7.2.3 requiere que
b col
d h 20 > para conexiones de prticos
especiales. En nuestro caso, cm cm d
b
38 9 . 1 20 20 = = . En el caso de un prtico especial, el
tamao de la columna cumple.


Diseo por Confinamiento:

Finalmente, hay que revisar el confinamiento (Seccin 21.7.3):

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


162
yt
c
c sh
ch
g
yt
c c
sh
f
f
b s A pero
A
A
f
f b s
A
' '
09 . 0
2
1
1
3 . 0
2
1
|
.
|

\
|
>
|
|
.
|

\
|
|
.
|

\
|
=

y cm s 15 s .

En las ecuaciones de arriba, los factores de (1/2) se deben a la existencia de vigas confinantes.

Entre poco, vamos a ver el significado de estos requisitos. Por ahora,

2 2
2
2
2
2
2
2
' '
36 . 2 63 . 2
/ 4200
/ 420
) 8 60 ( 10 09 . 0
2
1
1
52
60
/ 4200
/ 420 ) 8 60 ( 10 3 . 0
2
1
09 . 0
2
1
1
3 . 0
2
1
cm A pero cm A
cm kg
cm kg
cm cm A pero
cm kg
cm kg cm cm
A
f
f
b s A pero
A
A
f
f b s
A
sh sh
sh
sh
yt
c
c sh
ch
g
yt
c c
sh
> =
|
.
|

\
|
>
|
|
.
|

\
|


|
.
|

\
|
=
|
.
|

\
|
>
|
|
.
|

\
|
|
.
|

\
|
=


Suponiendo 1 amarre cerrado y un amarre suplementario,

2
2
var
88 . 0
3
63 . 2
cm
cm
A
illa
= =

Seguir con los amarres de columna de 12 mm y amarres suplementarios en 10 cm.



8.6.2 Diseo Preliminar de Una Conexin Viga-Columna Exterior


Tenemos que disear la conexin por corte, por anclaje, y por confinamiento.



Diseo por Corte:

Tenernos que calcular primero el corte en las columnas. Supongamos que existen puntos de inflexin
en la mitad de cada columna. Los pisos tienen altura de 3m.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


163


Usar

( )
( )
T
cm
cm T
V
cm T cm cm kg cm M
d d f A M
col
y s n
22 . 2
300
9 . 666
9 . 666 14 / 4200 9 . 1
4
4
2 2
1
'
=

=
= =
~
t



T V
T T T cm kg V
V f A V
conexion
conexion
columna y s conexion
32 . 57
22 . 2 5 . 59 22 . 2 / 4200 25 . 1 34 . 11
2
1
=
= =
= o




Calcular la capacidad cortante de la conexin por

T
T V
V
A v V
u requerido
n
conexion conexion n
44 . 67
85 . 0
32 . 57
= = =
=
o


Puesto que no tenemos vigas confinantes en solamente tres lados de la conexin,

conexion c n
A f V
'
92 . 3 =

El rea efectiva de la conexin se define en la Seccin 21.7.4.1 del ACI 318-08:

+
+
=
x b
h b
h A
col j
2
min


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


164


En nuestro caso, el ( )
col
b x b = + 2 gobierna.
( ) Bien V T kg cm V
requerido
n n
> = = = 2 . 289 289210 60 420 92 . 3
2



Diseo por Anclaje:

Segn la Seccin 21.7.5.1 del ACI 318-08,

cm
cm kg
cm cm kg
f
d f
c
b y
dh
68 . 22
/ 420 17 . 17
9 . 1 / 4200
17 . 17
2
2
'
=

= =


Esta es la distancia entre el plano crtico (punto de esfuerzo mximo a lo largo de la varilla) y la
parte posterior del gancho. La longitud disponible es la distancia entre la cara exterior de los
amarres de la columna en el lado de viga, y la cara interior de los amarres en el lado opuesto.

Esta distancia es

Bien cm cm cm d nto recubrimie h
amarre col le disisponib
23 8 . 50 2 . 1 4 2 60 2 > = = =


Diseo por Confinamiento:

Finalmente, hay que revisar el confinamiento (Seccin 21.7.3):

yt
c
c sh
ch
g
yt
c c
sh
f
f
b s A pero
A
A
f
f b s
A
' '
09 . 0 1
3 . 0
>
|
|
.
|

\
|
=

y cm s 15 s .

Esta vez, no hay factores de (1/2), pues hay vigas confinantes slo en tres lados de la conexin. La
segunda ecuacin no gobierna para columnas cuadradas.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


165
2
2
2
2
2
'
17 . 5
1
52
60
/ 4200
/ 420 ) 8 60 ( 10 3 . 0
1
3 . 0
cm A
cm kg
cm kg cm cm
A
A
A
f
f b s
A
sh
sh
ch
g
yt
c c
sh
=
|
|
.
|

\
|


=
|
|
.
|

\
|
=


Suponiendo 1 amarre cerrado y un amarre suplementario,

2
2
var
72 . 1
3
17 . 5
cm
cm
A
illa
= =

Usar amarres de 12 mm y amarres suplementarios en 8 cm.



8.7 Diseo Preliminar del Ncleo

8.7.1 Diseo Preliminar del Ncleo por Flexin

Suponer que las alas del ncleo tienen ancho efectivo de 1.5 m en cada lado. Por consiguiente, el
muro cortante tiene ancho total de 3 m, con tal de que el eje neutro se quede en el ala.



6 m
6 m
1.5 m 1.5 m
3 m
6 m
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


166

Para esta seccin, otra vez podemos aglomerar el acero para caber en 7 capas o menos.




A continuacin se muestra el diagrama M-N para el ncleo:



Las clulas de la hoja correspondiente se muestran aqu:


area real es de 5.16 cm2 cada 30 cm
90 cm 120 cm
60 cm
6 m
4 capas de varillas de 12 mm cada 30 cm
15 30
20.64 cm2 20.64 cm2
10.32 cm2
75 cm
300 cm
2 capas de varillas de 12 mm cada 30 cm por 3 m = 51.6 cm2
56.76 cm2 56.76 cm2
90 cm 120 cm 75 cm
0
5000
10000
15000
20000
25000
30000
35000
40000
0 5000 10000 15000 20000 25000 30000 35000
P
n
,

T
Mn, T-m
Diagrama de Interaccion M-N
Nucleo 6 x 6 m del Ejemplo de Seccion 8.7
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


167




La combinacin de carga que gobierna es

E D U 0 . 1 9 . 0 + =


De la Seccin 8.3,

m T m T M
T T V
T T P
u
u
u
= =
= =
= =
14681 14681 0 . 1
864 864 0 . 1
622 2 . 691 9 . 0


Con una fuerza axial de diseo de 622 T, la capacidad nominal a flexin del ncleo muro con el
refuerzo vertical dado es de unos 5000 T-m. Habr que contar con los muros perimetrales tambin (ver
a continuacin).


Hoja de calculo para diagrama M-N para nucleo
profundidad 600
ecu 0.003
f'c 281
beta1 0.85
fy 4200
Es 2.03E+06
d 563.88
(c/d)balanceado 0.591837
ancho 300
capas de acero se cuentan de la fibra extrema en compresion, hacia la varilla extrema en traccion
las distancias se miden de la fibra extrema en compresion
la compresion en concreto y refuerzo se toma como positiva
los esfuerzos en acero compresivo se ponen iguales a cero, pues el refuerzo no se apoya lateralmente
Capa de Refuerzo distancia Area
1 15.00 56.76
2 90.00 20.64
3 210.00 20.64
4 300.00 10.32
5 390.00 20.64
6 510.00 20.64
7 585.00 56.76
c/d c Cconc fs(1) fs(2) fs(3) fs(4) fs(5) fs(6) fs(7) Momentouerza Axia
compresion pura 0 36502
puntos controlados por concreto 1.063 599.40 36507776 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16521 36508
0.9 507.49 30909688 0.00 0.00 0.00 0.00 0.00 -30.10 -930.11 26214 30856
0.8 451.10 27475279 0.00 0.00 0.00 0.00 0.00 -795.11 -1807.62 30077 27356
0.7 394.72 24040869 0.00 0.00 0.00 0.00 0.00 -1778.70 -2935.86 32345 23838
0.591837 333.72 20326099 0.00 0.00 0.00 0.00 -1026.94 -3216.77 -4200.00 32987 20000
puntos controlados por acero 0.591837 333.72 20326099 0.00 0.00 0.00 0.00 -1026.94 -3216.77 -4200.00 32987 20000
0.5 281.94 17172049 0.00 0.00 0.00 -390.10 -2334.13 -4200.00 -4200.00 31845 16795
0.4 225.55 13737639 0.00 0.00 0.00 -2010.13 -4200.00 -4200.00 -4200.00 28984 13305
0.3 169.16 10303229 0.00 0.00 -1470.12 -4200.00 -4200.00 -4200.00 -4200.00 24414 9818
0.2 112.78 6868820 0.00 0.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 18176 6327
0.063 35.52 2163678 0.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 6844 1535
0.01 5.64 343441 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 1022 -523
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


168

8.7.2 Diseo Preliminar del Ncleo por Corte


Calcular la resistencia cortante del ncleo. Incluir solamente el rea del alma:

T kg V
gobierna kg pero kg
kg
de menor V
cm V
m m
cm
cm kg
cm cm
de menor V
d h f V pero d h
V
M
h
N
f
f
d N
d h f
de menor V
c
c
c
c
c c
w
w
c w
c
w
u
c
c
8 . 255 871 , 255
871 , 255 924 , 136
643 , 597
600 8 . 0 60 281 53 . 0 600 8 . 0 60
100
2
6
864
14600
60 600
10 864
2 . 0 281 33 . 0 600
281 16 . 0
600 4
600 8 . 0 10 864
600 8 . 0 60 281 88 . 0
53 . 0
2
2 . 0 33 . 0
16 . 0
4
88 . 0
3
3
'
'
'
'
= =

>
=

>

|
.
|

\
|

|
|
.
|

\
|

+
+


+
=

>

|
.
|

\
|

|
|
.
|

\
|
+
+
+
=



No tenemos capacidad cortante suficiente del ncleo slo. Al igual que con la flexin, tenemos que
contar con los muros perimetrales tambin.


8.8 Diseo Preliminar de los Muros Perimetrales
En esta parte del diseo, se revisan los muros perimetrales por el resto de la fuerza lateral. Cada
muro perimetral tiene rea tributaria de 6 por 3 metros, y por consiguiente una carga axial (no
mayorada) de 18 T por piso, o 144 T.


8.8.1 Diseo Preliminar de los Muros Perimetrales por Flexin

Cada muro perimetral tiene largo en planta de 6 m, espesor de 30 cm, y refuerzo de varillas de 12
mm en 30 cm. Este arreglo es casi igual a lo estudiado antes. Para esta seccin, otra vez podemos
aglomerar el acero para caber en 7 capas o menos.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


169



A continuacin se muestra el diagrama M-N para un muro perimetral:



Las clulas de la hoja correspondiente se muestran aqu:





areas reales de 2.54 cm2 cada 30 cm
90 90 75 75 90 90 45
30 cm
6 m
varillas de 12 mm cada 30 cm
15 30
3.87 cm2 3.87 cm2
2.58 cm2
45
0
500
1000
1500
2000
2500
3000
3500
4000
0 500 1000 1500 2000 2500 3000 3500
P
n
,

T
Mn, T-m
Diagrama de Interaccion M-N para Muro Perimetral
f'c=281 kg/cm2, 6 m de largo, 30 cm de espesor, 2 varillas de 12 mm en 30 cm
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


170





La combinacin de carga que gobierna es

E D U 0 . 1 9 . 0 + =


De la Seccin 8.3 y arriba, para cada muro perimetral,

T T P
u
6 . 129 144 9 . 0 = =

Con una fuerza axial de diseo de 129.6 T, la capacidad nominal a flexin del cada muro perimetral es
de unos 1000 T-m.

La capacidad a flexin del ncleo ms los 8 muros perimetrales en cada direccin principal de la
estructura es unos 5000 T-m para el ncleo, ms 1000 T-m para cada uno de los 8 muros perimetrales,
por un total de 13000 T-m. Con un factor o de 0.90 para muros ligeramente cargados axialmente, la
demanda a flexin es de unos 14,600 T-m dividido por 0.9, o unos 16,000 T-m. La capacidad nominal
total a flexin (13,000 T-m) llega bastante cerca de la demanda total (16,000 T-m). A lo mejor,
refinamiento con anlisis a computadora podra confirmar la validez del diseo preliminar.


Hoja de calculo para diagrama M-N para muro perimetral
profundidad 600
ecu 0.003
f'c 281
beta1 0.85
fy 4200
Es 2.03E+06
d 563.88
(c/d)balanceado 0.591837
ancho 30
capas de acero se cuentan de la fibra extrema en compresion, hacia la varilla extrema en traccion
las distancias se miden de la fibra extrema en compresion
la compresion en concreto y refuerzo se toma como positiva
los esfuerzos en acero compresivo se ponen iguales a cero, pues el refuerzo no se apoya lateralmente
Capa de Refuerzo distancia Area
1 45.00 7.74
2 135.00 7.74
3 225.00 7.74
4 300.00 5.16
5 375.00 7.74
6 465.00 7.74
7 555.00 7.74
c/d c Cconc fs(1) fs(2) fs(3) fs(4) fs(5) fs(6) fs(7) Momentouerza Axia
compresion pura 0 3644
puntos controlados por concreto 1.08 608.99 3709163 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1527 3709
0.9 507.49 3090969 0.00 0.00 0.00 0.00 0.00 0.00 -570.10 2617 3087
0.8 451.10 2747528 0.00 0.00 0.00 0.00 0.00 -187.60 -1402.62 3005 2735
0.7 394.72 2404087 0.00 0.00 0.00 0.00 0.00 -1084.40 -2472.99 3242 2377
0.591837 333.72 2032610 0.00 0.00 0.00 0.00 -753.21 -2395.58 -4037.95 3330 1977
puntos controlados por acero 0.591837 333.72 2032610 0.00 0.00 0.00 0.00 -753.21 -2395.58 -4037.95 3330 1977
0.5 281.94 1717205 0.00 0.00 0.00 -390.10 -2010.13 -3954.16 -4200.00 3239 1637
0.4 225.55 1373764 0.00 0.00 0.00 -2010.13 -4035.16 -4200.00 -4200.00 2964 1267
0.3 169.16 1030323 0.00 0.00 -2010.13 -4200.00 -4200.00 -4200.00 -4200.00 2499 896
0.2 112.78 686882 0.00 -1200.11 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 1853 526
0.063 35.52 216368 -1624.41 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 667 20
0.01 5.64 34344 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 -4200.00 102 -182
Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


171
8.8.2 Diseo Preliminar de los Muros Perimetrales por Corte

Calcular la resistencia cortante del cada uno de los muros perimetrales:

T kg V
gobierna kg pero kg
kg
de menor V
cm V
m m
cm
cm kg
cm cm
de menor V
d h f V pero d h
V
M
h
N
f
f
d N
d h f
de menor V
c
c
c
c
c c
w
w
c w
c
w
u
c
c
9 . 127 694 , 127
936 , 127 694 , 38
341 , 238
600 8 . 0 30 281 53 . 0 600 8 . 0 30
100
2
6
864
14600
30 600
10 6 . 129
2 . 0 281 33 . 0 600
281 16 . 0
600 4
600 8 . 0 10 6 . 129
600 8 . 0 30 281 88 . 0
53 . 0
2
2 . 0 33 . 0
16 . 0
4
88 . 0
3
3
'
'
'
'
= =

>
=

>

|
.
|

\
|

|
|
.
|

\
|

+
+


+
=

>

|
.
|

\
|

|
|
.
|

\
|
+
+
+
=


La capacidad nominal cortante del ncleo ms los 8 muros perimetrales en cada direccin principal de
la estructura es 255.8 T para el ncleo, ms 127.9 T para cada uno de los 8 muros perimetrales, por un
total de 1,279 T. Con un factor o de 0.75 para corte, la capacidad de diseo del ncleo ms los muros
perimetrales es 959 T. Esta sobrepasa la demanda de 864 T, y el diseo preliminar cumple.



8.9 Observaciones sobre el Refinamiento del Diseo

1) El diseo instantneo preliminar casi cumple con todos los requisitos de diseo. No hay
mucho ms que hacer.


2) El nico aspecto no ptimo de diseo preliminar es la necesidad de usar concreto de 420
kg/cm
2
para las columnas, para evitar secciones demasiado grandes. Si hubiramos usado
concreto de 280 kg/cm2, habramos tenido que usar columnas de

cm cm h 74
280
420
60 = |
.
|

\
|
=

Un diseo ms refinado podra incluir la posibilidad de usar concreto de 280 kg/cm
2
en las
columnas.


Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


172
3) No hay mucho ms que refinar. Todos los elementos arquitectnicos estn trabajando
estructuralmente. El ncleo no puede hacerse ms pequeo, ni ms delgado. Habra que ver
por el confinamiento del ncleo.


4) Debido a los muros en la estructura, la deriva lateral se controla muy bien.

Diseo Sismo-resistente del Concreto Reforzado R. E. Klingner


173

9. REFERENCIAS


Norma de diseo en concreto reforzado:

ACI 318-08: Building Code Requirements for Structural Concrete, American Concrete Institute,
Farmington Hills, Michigan, 1998.



Cualquier libro de texto moderno sobre el concreto reforzado:

Wang, Salmon, and Pincheira, Reinforced Concrete Design, Wiley, 2006.

McGregor and Wight, Mechanics and Design of Reinforced Concrete, Prentice-Hall, 2009.

Anda mungkin juga menyukai