EMERGENCY TROUBLE REPORT

REPORT NO. JYP/002/ETR/2022


REPORT DATE 26 Jul 22
BRANCH JAYAPURA
CUSTOMER BUSINESS CONSTRUCTION
CUSTOMER NAME PT.GARANTAH BANGUN PERKASA
MACHINE LOCATION PEGUNUNGAN BINTANG
REPORTED BY
SERVICE REQ. NO

SYMPTOM :

BEBERAPA KOMPONEN MENGALAMI KERUSAKAN ( WATER PUMP BROKEN, HEATER ELEMENT BOCOR, V

FAILURE : Crack, Dent, Worn, Scratch, Short Circuit, Burn, Bend, Loose, Rusty, Pitting, Br

WATER PUMP RUSAK

VIBRO CONTROL SWITCH ABNORMAL


VIBRO CONTROL SWITCH ABNORMAL

KETERANGAN :
# TERJADI KERUSAKAN PADA COOLING PUMP/WATER PUMP ( BERAING JAMMED ) SEHINGGA MENYEBABKAN PUTARA
SAAT DILAKUKAN CRANKING.UNTUK MEMASTIKAN PROBLEM YANG LAIN, PERLU DILAKUKAN PERBAIKAN PADA KOM
DAHULU.
# TERDAPAT KEBOCORAN PADA BAGIAN ENGINE ( ELEMENT HEATER DAN ROCKER ARM COVER ).
# TERJADI ABNORMAL PADA VIBRO CONTROL SYSTEM, SEHINGGA DARI PIHAK MEKANIK CUSTOMER MELAKUKAN MO
BERDASARKAN INFO DILAPANGAN.
# OLEH KARENA UNIT SUDAH TIDAK PERNAH DIRUNNING SELAMA ± 4 BULAN, KAMI SARANKAN MELAKUKAN PENGGA
ENGINE, SEHINGGA ENGINE DALAM KONDISI SIAP OPERASI SAAT SETELAH DILAKUKAN PERBAIKAN.
PT UNITED TRACTORS Tbk

CY TROUBLE REPORT
MACHINE MODEL BW 211D-40
MACHINE SERIAL NO. 101582421056
ENGINE MODEL BF4M2012
ENGINE NUMBER
SMR./HRS.
DELIVERY DATE
TROUBLE DATE
CORRECTED DATE

SYMPTOM :

ATER PUMP BROKEN, HEATER ELEMENT BOCOR, VIBRO MULFUNCTION, ETC)

tch, Short Circuit, Burn, Bend, Loose, Rusty, Pitting, Broken etc

KEBOCORAN PADA ELEMENT HEATER ENGINE


KEBOCORAN PADA ELEMENT HEATER ENGINE

BERAING JAMMED ) SEHINGGA MENYEBABKAN PUTARAN ENGINE MENJADI BERAT


YANG LAIN, PERLU DILAKUKAN PERBAIKAN PADA KOMPONEN TERSEBUT TERLEBIH

EATER DAN ROCKER ARM COVER ).


GGA DARI PIHAK MEKANIK CUSTOMER MELAKUKAN MODIFIKASI PADA WIRING.INI

AMA ± 4 BULAN, KAMI SARANKAN MELAKUKAN PENGGANTIAN OLI DAN FILTER PADA
SAAT SETELAH DILAKUKAN PERBAIKAN.