A C C E S S C ON T R O L

WARRANTY All Fermax products have a 24 months warranty. Fermaxobligation under this warrany, however, is expressly limited (at Fermaxoption) to replacing, repairing, or issuing credit for any product returned to FERMAX within twenty four (24) months from date of shipment by FERMAX and then only if: (a) the defective product is returned to FERMAX, transport charges prepaid, (b) examination of the product discloses to FERMAXsatisfaction that defects in the product have not been caused by misuse, neglect, improper installation, repair alteration or accident and (c) returned material must attach the Authorization for return form. This warranty does not cover problems arising due causes with equipment (for example deficiencies in installation or incorrect wiring), nor breakdowns caused by incorrect manipulation of blows. LIMIT OF LIABILITY It is expressly understood and agreed that FERMAX is not an insurer that the products or services sold hereunder will perform functions or prevent: that FERMAX shall be exempt from liability for all loss or damage therefrom; and that insurance, if any, shall be obtained by the Distributor. Liability shall be limited to an amount to the consideration paid by the distributor for such products or services as the distributor exclusive remedy. DELIVERY 15 days after order confirmation and reception of payment. Allow 30 days for special orders. Every endeavour will be made by the Company to adhere to the delivery dates quoted, but such dates are only estimate and are not guaranteed neither shall they be a term of condition between the Buyer and the Company. The Buyer shall be responsible for arranging insurance on goods collected by their own carriers. Delay in delivery shall by no means entitle the Buyer to cancel the order or thereby render the Seller liable to the Buyer for any loss or expense arising from the delay unless otherwise agreed in writing. Ex works. OWNIRSHIP OF GOODS The goods shall remain the property of the Seller until paid for in full by the Buyer. CANCELLATION Cancellation of any order or goods or any part of an order will not be valid after the Buyer has placed the order unlessthe cancellation is accepted by the Seller in writing.

Dear partner, This fourth edition of the Access Control catalogue takes in the complete range of FERMAX solutions for access restriction. You can choose the most suitable option according to the specific needs and features of the installation: Styling: for interiors, outdoors or vandal-proof version. Reader technology: keypad, proximity, radio frequency, fingerprint and Bluetooth. System: Stand-alone (1 access), stand-alone in network (32 accesses) and centralized (large installations). This new document has been designed to provide you with detailed and structured information on all the options, in technical file format, for easy understanding and use by the professional.

The main new features that you will find in this edition are: Stand-alone system. The Bluetooth Kit lets you open the door with a mobile phone. It is a technological and innovating product. City Fingerprint Reader. Cutting-edge technology now at a highly competitive price. Includes thermal reader technology, recommended in exteriors. Storage capacity: 950 fingerprints. Marine Readers for exteriors made in stainless steel, now available in keypad version (Memokey) and proximity (Private). New RF remote control line with an exclusive design and more robust mechanics. We emphasize the versatility offered by our access control range for integration in any video entry system panel. Ask for the modular format of the desired reader and integrate it in an outdoor panel. Stand-alone system in network. Recommended for average size applications - up to 32 accesses and 1000 users. Management handled from intuitive and practical PC software. An interesting balance between benefits and simplicity in system management and start-up.

Centralized system. The new software that comes as standard with the Central Unit also includes management of user authorizations/cancellations and access permits/restrictions and now also time & attendance software for staff clock-in management and calculation of hours worked (for pays management). You can also find all updated information on our products in the product section of our website www.fermax.com. Thank you for your confidence.

Jeremy Palacio Access Control Product Manager

Stand-alone Stand-alone in network Centralized Accessories

1 1 37 49 75

Content Guide

QUICK GUIDE Keypad

City
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 3610 3600 4480 23291

Bruto
ref. 4500 2133 2553

Loft
ref. 4540 3623 4550
4550+4420

Citymax Module
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 2520 2561

Bruto Module
ref. 2523 22371

Marine
ref. 4699 -

Proximity

City
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 2347 2260 4490 23351
or 4490+4420

Bruto
ref. 4520 4510 2552
or 4510+4420

Loft
ref. 4530 3624 4560
4560+4420

Citymax Module
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 2263 2560

Bruto Module
ref. 2288 2268

Marine
ref. 4698 -

06

QUICK GUIDE Radio frequency

PCB Module
Description ref.

Box Receiver
ref. 7960 7912 -

DIN Rail MDS


ref. 7903 7910 -

Single Channel Receiver


ref. 7952 7911 1065

MDS Secondary Receiver


ref. 2464

7900 STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED

Key button

City
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 2315 23261
or 2315+4420

Bruto
ref. 2554

Bluetooth

Bluetooth

TM

Bluetooth

TM

City
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 4477 4478 -

Citymax Module
ref. 4476 -

Fingerprint

Optical Reader
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED ref. 4470+4420

City
ref. 6990 6988 6990
6990+4420

Citymax Module
ref. 6989 6989
6989+4420

07

Stand-alone - The easiest access control to install. No PC required.


An ideal access control solution for indoors and outdoors, to manage a single access or door in the most practical and simple way. Swift and easy to install: only two power supply cables. Reader technologies available are keypad, proximity readers, radio frequency systems, Bluetooth technology and digital fingerprint.

Stand-alone in network - Secure and practical access control. PC required.


The stand-alone access control system in network is recommended when you want to manage permits/restrictions for up to 32 accesses or doors from a PC. The online events record enables a fast graphic view of incoming and outgoing user flow.

Centralized - The most complete and versatile solution. PC Required.


Enables complete management of an installation with multiple accesses (up to 2048) and advanced access control functions. There are two systems: MDS and CAC. MDS is recommended in installations with audio or video door entry systems and access control functions, alarms and automation. CAC is the best option for purely access control installations thanks to its new functions: vehicle control and time & attendance for salary management. Also includes alarms management and automation.

Accessories - Common to all the access control systems. 08

Reference chart/index

READER
KEYPAD
CITY CITYMAX MODULE BRUTO BRUTO MODULE LOFT MARINE

STAND-ALONE R E
3610 2520 4500 2523 4540 4699

STAND-ALONE IN NETWORK E R E
4480 * (0) 4550 *(1) -

CENTRALIZED (MDS and CAC) C E


23291 2561 2553 22371 4550* (1)+4420 -

PROXIMITY
CITY CITYMAX MODULE BRUTO BRUTO MODULE LOFT MARINE

2347 2263 4520 2288 4530 4698

4490 4510 4560 -

23351 o 4490+4420 2560 2552 o 4510+4420 2268 4560+4420 -

KEY BUTTON
CITY CITYMAX MODULE BRUTO BRUTO MODULE

2315 -

23261 o 2315+4420 2554 -

RADIOFREQUENCY
PCB MODULE RECEIVER BOX RECEIVER DIN RAIN MODEL RECEIVER SINGLE CHANNEL RECEIVER MDS SECUNDARY RECEIVER

7900 7960 7903 7952 -

1065 2464

BLUETOOTH
CITY CITYMAX MODULE

4477 4476

FINGERPRINT
OPTICAL READER A CITY N CITYMAX MODULE

6990 6989

6990 6989

4470+4420 6990+4420 6989+4420

NOTE: The symbol - indicates that there is no such combination. *(0) Ref.4480 is a keypad and proximity reader. *(1) Ref.4550 is a keypad and proximity reader.

09

Simple access control system managing one access.

Stand-alone access control

STAND-ALONE

Memokey
stand-alone

City Memokey (ref.3610)


Access control keypad with capacity for up to 100 different of 4 to 6-digit codes. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module (ref.3610) or separate (ref.3620 and ref.3621).

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.

Programming

Programming from the keypad by Master code.

Installation

230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

2
1 4 7 A 2 5 8 0 3 6 9 B

Ref.3610 2

Door release

Exit button

Specifications

Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07

Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay Contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

12

Available in kit (ref.3600)

Memokey
stand-alone

City Memokey CR (ref.3620+3621)


Reader (ref.3620) and controller (ref.3621) in two stand-alone modules for enhanced security. The controller is installed indoors next to the power supply and door release. Metallic box included with controller (measurements: 154x203x50mm). A second CR keypad can be added on the inside. Maximum distance: 100 meters.

Memokey City CR (ref.3620)

Memokey controller CR (ref.3621)

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other fuctions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper. Electric lock unblocking by code (free access).

Programming

Programming from keypad by Master code.

Installation
2

230Vac Power supply 2

The CR keypad is located on the outside, connected to the controller situated in the interior, the same as the rest of the devices: power supply and electric lock. Optionally, an exit pushbutton can be used (if there is no door handle) and a second CR keypad on the inside.

Ref.3620
1 4 7 A 2 5 8 0 3 6 9 B

Ref.3621

Exit button

Door release

Specifications

Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Metallic box (WxHxDmm): 154x203x50 Environmental protection (IP): 43 Protection against knocks (IK): 07

Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

Available in kit (ref.3591)

13

STAND-ALONE

STAND-ALONE

Memokey
stand-alone

City Memokey Module (ref.2520)


Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in aluminium. To be fitted in CityMax audio or video door entry system outdoor panels to improve home security. Reader and controller integrated in the same module (ref.2520).

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Open collector auxiliary output (150mA max) to indicate sabotage attempt or door open/forced. Electric lock unblocking by code (free access).

Programming

Programming from keypad by Master code.

Installation
230Vac Power supply 2

Audio or video door entry panel located in the outside area. It is possible to set up the panel intuitively to include a keypad (ref.2520) for greater security and more convenient access.

Door release
1 4 7 A 2 5 8 0 3 6 9 B

Ref.2520 2

Exit button

Specifications

Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

14

Memokey
stand-alone

Bruto Memokey (ref.4500)


Access control keypad with capacity for up to 100 different 4 a 6-digit codes. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.

Programmation

Programming from keypad by Master code.

Installation
230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

1 4 7

2 5 8

3 6 9

A 0 B

Ref.4500 2 Exit button

Door release

Specifications

Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box(WxHxDmm): 135x131x42 Environmental protection (IP): 53 Protection against knocks (IK): 09

Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

Available in kit (ref.2133)

15

STAND-ALONE

STAND-ALONE

Memokey
stand-alone

Bruto Memokey Module (ref.2523)


Access control keypad with capacity for up to 100 different 4- to 6-digit codes. Vandal-proof keypad. To be fitted in Bruto audio or video door entry panel viewers for enhanced security in the home. Reader and controller integrated in the same module (ref.2523).

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.

Programmation

Programming from keypad by Master code.

Installation

230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

Door release Ref.2523 2 Exit button

Specifications

Environmental protection (IP): Protection against knocks (IK): Power supply (V): Consumption (mA) without door release: Relay contact: Programable from 01 to 99 sec. or bistable Operating temperature:

53 09 12V (ac/dc) 6/60 2A (NA,NC) 0 to 70C

16

Memokey
stand-alone

Loft Memokey (ref.4540)


Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Reader and controller integrated in the same module Ideal for screen profiles in offices. Includes a 50cm cable.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. Multi-function OC output: coercion alarm, wrong code and forced door. Electric lock unblocking by code (free access). Status LEDs: door open/closed/power supply.

Programmation

Programming from keypad by Master code.

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

Ref.4540
1 4 7 A 2 5 8 0 3 6 9 B

Door release

Exit button

Specifications

Dimensions (WxHxDmm): 60x130x23 Flush box: Not required Superface box (WxHxDmm):Not required Environmental protection (IP): 66 Protection against knocks (IK): 06

12V (ac/dc) Power supply (V): Consumption (mA) without door release: 20/70 2A (NA,NC) Relay contact: 0 to 70C Operating temperature:

Availalble in kit (ref.3623)

17

STAND-ALONE

STAND-ALONE

Memokey
stand-alone

Marine Memokey (ref.4699)


Access control keypad with capacity for up to 100 different 4- to 6-digit codes. Stainless steel panel 2.5mm thickness. Keypad with 4x3 layout and orange backlight. Flush or surface mounted (ref.4645). Recommended for interiors and exteriors. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.

Programmation

Programming from keypad by Master code.

Installation
230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

1 4 7 A

2 5 8 0

3 6 9 B

Ref.4699 2 Exit button

Door release

Specifications

Dimensions (WxHxDmm): 153x123x50 Flush box (included): 130x160x55 Superface box (WxHxDmm):154x184x73 Environmental protection (IP): 53 Protection against knocks (IK): 09

12V (ac/dc) Power supply (V): Consumption (mA) without door release: 6/60 2A (NA,NC). Relay contact: Programmable from 01 to 99 sec. or bistable 0 to 60C Operating temperature:

18

Private
stand-alone

City Private (ref.2347)


Proximity card reader with capacity for up to 400 users. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.

Programmation

Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

2
( restricted area )
PRIVATE ACCESS CONTROL

Ref.2347 2 Exit button

Door release

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifiers Specifications

ref.23361

ref.2336

ref.2336 Relay contact:

ref.2364

ref.44501

Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Superface box (WxHxDmm):130x128x33 43 Environmental protection (IP): 07 Protection against knocks (IK): 12V (ac/dc) Power supply (V): Cons. (mA) without door release: 80/120

2A (NA,NC). Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 60C Reading distance (card/keyring): 6/5 cm IP Interface: RS-232

Available in kit (ref.2260)

19

STAND-ALONE

STAND-ALONE

Private
stand-alone

City Private Module (ref.2263)


Proximity card reader with capacity for up to 400 users. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs. Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).

Programmation

Installation
2 230Vac Power supply 2

The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a keypad (ref.2263) for greater security and more convenient access.

2 Ref.2263 2 Exit button

( restricted area )

Door release

PRIVATE ACCESS CONTROL

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

43 Environmental protection(IP): 07 Protection against knocks (IK): 12V (ac/dc) Power supply (V): Cons. (mA) withot door release: 80/120 2A (NA,NC). Relay contact:

Operating temperature: Reading distance (card/lkeyring): PC Interface:

0 to 60C 6/5 cm RS-232

20

Private
stand-alone

Private Bruto (ref.4520)


Proximity card reader with capacity for up to 400 users. Vandal-proof reader. To be fitted in the viewer of the Bruto audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.

Programmation

Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

2
( restricted area )

Ref.4520 2 Exit button

PRIVATE ACCESS CONTROL

Door release

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 135x130x18 115x100x45 Flush box (included): Superface box (WxHxDmm):135x131x42 53 Environmental protection (IP): 09 Protection against knocks (IK): 12V (ac/dc) Power supply (V): Comsumption (mA) door release 80/120

Relay contact

2A (NA,NC). Programmable from 01 to 99 sec. or bistable Operating temperature 0 to 60C Reading distance: (card/keyring): 4/2 cm PC Interface: RS-232

21

STAND-ALONE

STAND-ALONE

Private
stand-alone

Bruto Private Module (ref.2288)


Proximity card reader with capacity for up to 400 users. Vandal-proof reader. To be fitted in the viewer of the Bruto audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs. Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards. PC software: The most convenient solution for authorization and cancellation management (ref.2351).

Programmation

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

Door release Ref.2288 2


( restricted area )
PRIVATE ACCESS CONTROL

Exit button

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifications Specifications

ref.23361

ref.2336

ref.2363

ref.2364

ref.44501

Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 80/120 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

22

Private
stand-alone

Loft Private (ref.4530)


Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Reader and controller integrated in the same module Ideal for screen profiles in offices. Includes a 50cm cable .

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs. Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.3625)

Programmation

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

2 Ref.4530 Door release 2 Exit button

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 60x130x23 Not required Flush box (included): Superface box (WxHxDmm): Not required 66 Environmental protection (IP): 06 Protection against knocks (IK): 12V (ac/dc) Power supply (V):

Cons. (mA) without door release: 45/75 Relay contact: 2A (NA,NC). Operating temperature: 0 to 60C Reading distance (card/keyring): 8/6 cm PC Interface: RS-485

Available in kit (ref.3624)

23

STAND-ALONE

STAND-ALONE

Private
stand-alone

Marine Private (ref.4698)


Proximity card reader with capacity for up to 400 users. Stainless steel panel 2.5mm thickness. Flush or surface mounted (ref.4645). Recommended for interiors and exteriors. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs. Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card. which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref.1306). PC software: The most convenient solution for authorization and cancellation management (ref.2351)

Programmation

Installation
2 230Vac Power supply 2

Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

2
( restricted area )
PRIVATE ACCESS CONTROL

Ref.4698 2 Exit button

Door release

Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring.

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 153x123x50 Flush box (included): 130x160x55 Superface box (WxHxDmm):154x184x73 Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12V (ac/dc)

Cons. (mA) without door release: 80/120 Relay contact: 2A (NA,NC). Operating temperature: 0 to 60C Reading distance (card/keyring): 6/5 cm PC Interface: RS-232

24

Radiofrequency
stand-alone

Trinary RF emitter (ref.79561)


Radiofrequency emitter 433.92MHz. Trinary technology. New and highly robust design. Dual channel emitter that can activate two relays. Configuration of the sequence of digits required by means of microswitches. Simple and easy to use.

Technical features

Dip switch configuration (8 microswitches in 3 positions). Unlimited number of users admitted by the receiver. Includes battery 12Vdc. Range: 30m. Frequency: 433.92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA

Installation
RF Emitter Ref.79561 Receiver

2 Door release

Compatible with

ref.7952 Single channel receiver for garages.

ref.7900 Single channel receiver PCB (OEM).

ref.7903 Single channel receiver DIN rail.

Specifications

Dimensions (WxHxDmm): 53x36x13mm

Available in kit (ref.7910 y ref.7911)

25

STAND-ALONE

STAND-ALONE

Radiofrequency
stand-alone

Receiver for garages (ref.7952)


Single channel receiver 433.92MHz. Trinary technology. When the code emitted by the trinary emitter (ref.79561) is received, the receiver closes a circuit that triggers the electric lock or door automation. Mounted in watertight box (IP65) in ABS. Programming by 8 microswitches in 3 positions.

Technical features

Includes rigid antenna 25 cm. Optionally, by adding card ref.7934, the receiver can be turned into dual channel to trigger a second relay. Reception frequency: 433.92 MHz. Sensitivity: 3 mV Relay contact: 2 A max. Power supply: 220Vac/50Hz Consumption: 110 mA in standby.

Installation
Ref.7952 2

Ref.7934

Alarm

RF emitter Ref.79561

2 Door release

Compatible with

Trinary emitter (ref.79561)

Specifications

Dimensions (WxHxDmm): 90x165x55mm

26

Available in kit (ref.7911)

Radiofrequency
stand-alone

Single Channel Receiver (ref.7900)


Single channel receiver 433.92MHz. Trinary technology. The receiver admits all emitters (ref.79561) programmed with the same code. Can be installed in any FERMAX audio or video door entry panel.

Technical features

Trinary dip switch configuration (8 microswitches in 3 positions). Power supply: 12 Vdc/12 Vac. Frequency: 433.92 MHz. Output 12Vac to activate an electric lock. Output for pushbutton connection to open the door from inside.

230Vac Power supply

Installation
2

Ref.7900 (To be installed inside the flush box). Exit button

Door release 2

RF emitter (ref.79561)

Compatible with

Trinary emitter (ref.79561)

Specifications

Dimensions (WxHxDmm): 20x70x60mm

27

STAND-ALONE

STAND-ALONE

Radiofrequency
stand-alone

DIN rail receiver (ref.7903)


Single channel receiver 433.92MHz. Trinary technology. The receiver admits all emitters (ref.79561) programmed with the same code. Includes, in DIN6 format, the RF receiver and transformer or power supply. Ideal for shops, offices and businesses.

Technical features

Direct connection to 220Vac/50Hz. DIN rail or wall mounted. Output for pushbutton connection to open door from inside. Frequency: 433.92 MHz. Trinary dip switch configuration (8 microswitches in 3 positions). Output 12Vac for an electric lock activation. Dimensions: 6-element DIN.

Installation

Electric cabinet

REF.7903

Ref. 7903

RF emitter Ref. 79561

Compatible with

Trinary emitters (ref.79561)

Specifications

Dimensions (WxHxDmm): 105x90x60mm

28

Available in kit (ref.7910)

Radiofrequency
stand-alone

RF digital emitter (ref.24651)


Radiofrequency emitter 433.92MHz. Digital Technology. New and highly robust design. Dual channel emitter that can activate two relays. Secure code, unique, non configurable and exclusive as standard per emitter. It is necessary to authorize/cancel emitters in the receivers.

Technical features

Unique and exclusive code per emitter. Includes battery 12Vdc. Range: 30m. Frequency: 433.92 MHz. Consumption in transmission: 10 mA. Consumption in standby: 0.1mA

REF. 24561

RECEPTOR SEGURIDAD SECURITY RECEIVER

Installation
RF emitter Ref. 24651 RF receiver Ref.7960

2 Door release

Compatible with

Ref.7960 Villa receiver (stand-alone).

Ref.1065 MDS receiver (centralized).

Ref.2464 MDS Secondary receiver (centralized).

Specifications

Dimensions (WxHxDmm): 53x36x13mm

Available in kit (ref.7912)

29

STAND-ALONE

STAND-ALONE

Radiofrequency
stand-alone

Villa Receiver (ref.7960)


Radiofrequency receiver 433.92MHz. Digital technology. Only authorized digital (ref.24651) or dual (ref.25511) emitters will trigger the device. Reduced size enables installation in electrical cabinets (embeddable in standard boxes 10x10cm). Emitters must be authorized in the receiver.

Technical features

Power supply 12Vac/12Vdc. Lets you store up to 10 emitters (users) in memory with unique and different codes. Electric lock activation by relay. Programmable timing. Exit pushbutton input. Frequency: 433.92 MHz. Door open time programming by dip-switch.

REF. 7960

RECEPTOR SEGURIDAD SECURITY RECEIVER

Installation
RF emitter Ref. 24651 Receiver Ref.7960

2 Door release

Compatible with

Digital (ref.24651) or dual (ref.25511) emitters.

Specifications

Dimensions (WxHxDmm): 62x70x20mm

30

Available in kit (ref.7912)

Radiofrequency
stand-alone

Dual RF emitter (ref.25511)


Radiofrequency emitter 433.92MHz. Dual technology. New and highly robust design. Dual channel emitter can activate two relays. Secure code, unique, non configurable and exclusive as standard per emitter. It is necessary to authorize/cancel emitters in the receivers. Internally integrates proximity card electronics so can be used as a dual channel emitter and as substitute identifier for proximity cards or keyrings.

Technical features

In addition to the RF functions, incorporates proximity card electronics for use in any proximity reader. Includes battery 12Vdc. Range: 30m. Proximity reader distance: 2 cm. Frequency: 433.92 MHz. Consumption in transmission: 10mA. Consumption in standby: 0.1mA

Installation
RF emitter Ref.25511 Receiver for garages

2 Door release

Compatible with

Ref.7960 Villa receiver (stand-alone).

Ref.1065 MDS receiver (centralized).

Ref.2464 MDS secundary receiver (centralized).

Specifications

Dimensions (WxHxDmm): 53x36x13mm

31

STAND-ALONE

STAND-ALONE

Bluetooth
stand-alone

City Bluetooth (ref.4477)


Access control reader by Bluetooth technology where the mobile telephone acts as user identifier. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module.

Bluetooth

TM

Technical features

Electric lock activation by relay. Programmable relay time (monostable, bistable). Several operating modes: authorized personnel only (capacity 40 users) or without user limits. In authorized personnel only mode the door can be opened totally hands free, with key confirmation or PIN code. In no user limit mode the door is always opened by a PIN. Configurable reader range: up to 2m, 9m or 20m.

Programmation

Programming can be done in three ways: through a master mobile (recognized by the reader when powered up the first time) with simple and intuitive commands, by PC with Bluetooth connection (software downloadable from www.fermax.com) or by PDA with Bluetooth.

Installation
230Vac

The reader is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock.

Power supply 2 Door release 2 Ref.4477


Bluetooth
TM

Exit button

Specifications

Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Enviromental protection (IP): 43 Protection against knocks (IK): 07

Power supply (V): 12V (ac/dc) Cons. (mA) without door release: 80/200 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperatue: 0 to 70C

32

Available in kit (ref.4478)

Bluetooth
stand-alone

CityMax Bluetooth (ref.4476)


Access control reader by Bluetooth technology where the mobile telephone acts as user identifier. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller in the same module.

Bluetooth

TM

Technical features

Electric lock activation by relay. Programmable relay time (monostable, bistable). Several operating modes: authorized personnel only (capacity 40 users) or without user limits. In authorized personnel only mode the door can be opened totally hands free, with key confirmation or PIN code. In no user limit mode the door is always opened by a PIN. Configurable reader range: up to 2m, 9m or 20m.

Programmation

Programming can be done in three ways: through a master mobile (recognized by the reader when powered up the first time) with simple and intuitive commands, by PC with Bluetooth connection (software downloadable from www.fermax.com) or by PDA with Bluetooth.

Installation
2
230Vac

Power supply 2 Door release 2 Ref.4476


Bluetooth
TM

The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a reader (ref.4476) for greater security and more convenient access.

Exit button

Specifications

Enviromental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70C

33

STAND-ALONE

STAND-ALONE

Fingerprint
stand-alone

City fingerprint (ref.6990)


Fingerprint reader with thermal sensor and storage capacity for 950 prints. Manufactured in aluminium in new City styling. Flush or surface mounted. Recommended for interiors and exteriors. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Number of users: - 950 in 1 fingerprint per person mode. - 630 in 2 fingerprints per person mode. 2 status signal LEDs: door open/closed. Display 7-3-digit segments. Infrared receiver for programming. Electric lock activation by relay and one auxiliary relay. Programmable relay times (monostable, bistable).

Programmation

The system is programmed with one fingerprint (the administrators) and with a remote infrared keypad for user authorizations/cancellations.

Installation
2
230Vac

Power supply 2 Door release 2 Ref.6990 2 Exit button

The reader is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.

Specifications

Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Superface box (WxHxDmm):130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07

Power supply (V): 12V (ac/dc) Consumtion (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60C

34

Available in kit (ref.6988)

Fingerprint
stand-alone

City fingerprint module (ref.6989)


Fingerprint reader with thermal sensor and storage capacity for 950 prints. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.

Technical features

Exit pushbutton and free access button input. Number of users: - 950 in 1 fingerprint per person mode. - 630 in 2 fingerprint per person mode. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Electric lock activation by relay and one auxiliary relay. Programmable relay times (monostable, bistable).

Programmation

The system is programmed with one fingerprint (the administrator) and with a remote infrared keypad for user authorizations/cancellations.

Installation
230Vac Power supply 2

The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a reader (ref. 6989) for greater security and more convenient access.

Door release Ref.6989 2 Exit button

Specifications

Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc)

Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60C

35

STAND-ALONE

Access control systems consisting of several accesses (up to a maximum of 32) and PC managed.

Stand-alone

access

control

in

network

Controller
stand-alone in network

Door Controller (ref.44201)


Door controller with 500 event memory (ref.44201). Includes CD with management software. The door controller manages the devices in each access: up to two readers (if they are used as entrance and exit), electric lock, door sensor and exit button. Up to 32 door controllers can be connected in series to manage 32 entry and exit accesses. Thanks to the internal memory, it enables user authorizations/cancellations and access permits/restrictions from a PC. On-line incidents record. Capacity: 1.000 users. Indoor installation and separate from the reader for greater security. Admits Wiegand-26 input or magstrip.

STAND-ALONE IN NETWORK

Technical features

Each door controller manages 1.000 users. The connection between controllers consists of 2 power wires and a twisted pair for data. Admits an exit and entrance reader, electric lock relay, auxiliary relay for other functions, pushbutton connection, door sensor and free access button. Necessary for vehicle accesses for connection of entrance or exit detection coils. Status LEDs: transmission and reception. Lets you connect any reader with Wiegand-26 output or Magstrip (Aba TrackII or Dataclock). Admits Dallas i-button key readers and matrix keypads in 8-bit burst format. One power supply (ref.4813) recommended every 6 readers. Programmed from a PC with the corresponding software (included in ref.44201). Installation in mechanism box 100x100mm or surface mounted with 2 screws (included).

Programmation
2 wires Readers
2 wires twisted pair 2 wires
( restricted area )
PRIVATE ACCESS CONTROL

Installation
power supply

Up to 32 Readers

twisted pair 2 wires


( restricted area )
PRIVATE ACCESS CONTROL

2 wires

PC connection accessory (needed) ref.24661

twisted pair 2 wires twisted pair 2 wires twisted pair

twisted pair

PC Door controllers (ref.44201)

Specifications
38

Dimensions (WxHxDmm): Power supply (V):

85x88x25 Consumption (mA): 12Vdc Operating temperature:

15/100 0 to 60C

Memokey&Private WG
stand-alone in network

City Memokey&Private WG combination (ref.4480)


Access control reader with dual technology: proximity and keypad with capacity for up to 1.000 users. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in aluminium in City styling. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.

Programmation

Programming and start-up from PC software (included in ref.44201).

Installation
2 wires Readers
2 wires
( restricted area )
PRIVATE ACCESS CONTROL

Power supply

1 4 7 A

2 5 8 0

3 6 9 B

twisted pair 2 wires twisted pair 2 wires

Up to 32 Readers

The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.

( restricted area )

PRIVATE ACCESS CONTROL

2 wires

PC connection accessory (needed) ref.24661

( restricted area )

PRIVATE ACCESS CONTROL

twisted pair 2 wires twisted pair 2 wires twisted pair

twisted pair

PC Door controllers (ref.44201)

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Specifications

Dimensions (WxHxDmm): 130x175x18 115x162x45 Flush box (included): Surface box (WxHxDmm): 130x175x33 43 Environmental protection (IP):

Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30mA Operating temperature: 0 to 60C

39

STAND-ALONE IN NETWORK

Memokey&Private WG
stand-alone in network

Loft Memokey&Private WG (ref.4550)


Access control reader with dual technology: proximity and keypad with capacity for up to 1.000 users. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for screen profiles in offices. Includes a 50cm cable. Door controller (ref.44201) required for operation.

STAND-ALONE IN NETWORK

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply. Programming and start-up from PC software (included in ref.44201). The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.

Programmation

Installation
2 wires Readers
2 wires
1 4 7 A 2 5 8 0 3 6 9 B

Power supply

twisted pair 2 wires twisted pair 2 wires

( restricted area )

Up to 32 Readers

PRIVATE ACCESS CONTROL

2 wires
twisted pair

PC connection accessory (needed) ref.24661

( restricted area )

PRIVATE ACCESS CONTROL

twisted pair 2 wires twisted pair 2 wires twisted pair

PC Door controllers (ref.44201)

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 60x130x23 Flush box (Not required): Surface box (Not required): 66 Environmental protection (IP):

Protection against knocks (IK): 06 12Vdc Power supply (V): Cons. (mA) without door release: 40mA 0 to 60C Operating temperature:

40

Private WG
stand-alone in network

City Private WG (ref.4490)


Proximity card reader with capacity for up to 1.000 users. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.

Programmation

Programming and start-up from PC software (included in ref.44201).

Installation
2 wires Readers
2 wires
( restricted area )
PRIVATE ACCESS CONTROL

The reader is located outdoors and connected to the controller located in the interior. Can be combined with any Wiegand26 bit or Dataclock output reader.

Power supply

twisted pair 2 wires


1 4 2 5 8 0 3 6 9 B

Up to 32 Readers

7 A

twisted pair 2 wires

2 wires
twisted pair

PC connection accessory (needed) ref.24661

( restricted area )

PRIVATE ACCESS CONTROL

twisted pair 2 wires twisted pair 2 wires twisted pair

PC Door controllers (ref.44201)

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP): 07 Protection against knocks (IK): 12Vdc Power supply (V):

Cons. (mA) without door release: 30mA Operating temperature: 0 to 60C Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB

41

STAND-ALONE IN NETWORK

Private WG
stand-alone in network

Bruto Private WG (ref.4510)


Proximity card reader with capacity for up to 1.000 users. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.

STAND-ALONE IN NETWORK

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.

Programmation

Programming and start-up from PC software (included in ref.44201).

Installation
2 wires Readers
2 wires
( restricted area )
PRIVATE ACCESS CONTROL

Power supply

The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.

twisted pair 2 wires


1 4 2 5 8 0 3 6 9 B

Up to 32 Readers

7 A

twisted pair 2 wires


( restricted area )
PRIVATE ACCESS CONTROL

2 wires
twisted pair

PC connection accessory (needed) ref.24661

twisted pair 2 wires twisted pair 2 wires

PC Door controllers (ref.44201)

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

twisted pair

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 135x130x18 115x100x45 Flush box (included): Surface box (WxHxPmm): 135x131x42 53 Environmental protection (IP): 09 Protection against knocks (IK): 12Vdc Power supply (V):

Cons. (mA) without door release: 30 Operating temperature: 0 to 60C Reading distance (card/keyring): 4/2 cm PC Interface: RS-485/USB

42

Private WG
stand-alone in network

Loft Private WG (ref.4560)


Proximity card reader with capacity for up to 1.000 users. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for screen profiles in offices. Includes a 50cm cable. Door controller (ref.44201) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.

Programmation

Programming and start-up from PC software (included in ref.44201).

Installation
2 wires Readers
2 wires twisted pair 2 wires
( restricted area )

Power supply

The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.

Up to 32 Readers

PRIVATE ACCESS CONTROL

twisted pair 2 wires


( restricted area )
PRIVATE ACCESS CONTROL

2 wires
twisted pair

PC connection accessory (needed) ref.24661

twisted pair 2 wires twisted pair 2 wires twisted pair

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
PC

For replacement with magnetic strip.

Proximity keyring

Door controller (ref.44201)

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 60x130x23 Not required Flush box (included): Surface box (WxHxDmm): Not required 66 Environmental protection (IP): 06 Protection against knocks (IK): 12V (ac/dc) Power supply (V):

Cons. (mA) without door release: 40 Operating temperature: 0 to 60C Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB

43

STAND-ALONE IN NETWORK

Fingerprint WG
stand-alone in network

City fingerprint WG (ref.6990) WG fingerprint (ref.6990)


Fingerprint reader with thermal sensor and storage capacity for 1.000 prints. Manufactured in aluminium in new City styling. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.

STAND-ALONE IN NETWORK

Technical features

Door controller (ref.44201) required for operation. Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply. Display 7 3-digit segments. Infrared receiver for programming. Number of users: - 950 in 1 person mode. - 630 in 2 fingerprint mode. The system is programmed with one fingerprint (the administrators) and with a remote infrared keypad for user authorizations/cancellations. User authorizations and cancellations can be done from a PC with the software included in the door controller (ref.44201).

Programmation

Installation
2 wires
2 wires twisted pair 2 wires
( restricted area )

Power supply

PC connection accessory (needed) ref.24661

The reader is located outdoors and connected to the controller located in the interior. Can be combined with any Wiegand-26 bit or Dataclock output reader.

Up to 32 Readers

PRIVATE ACCESS CONTROL

twisted pair 2 wires


( restricted area )
PRIVATE ACCESS CONTROL

2 wires

PC connection accessory (needed) ref.24661

twisted pair 2 wires twisted pair 2 wires twisted pair

twisted pair

PC Door controller (ref.44201)

Readers

Specifications

Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP):

Protection against knocks (IK): 07 Power supply (V): 12Vdc Consumption (mA) without door release: 30 Operating temperature: 0 to 60C

44

Fingerprint WG
stand-alone in network

City WG Module Fingerprint (ref.6989)


Fingerprint reader with thermal sensor and storage capacity for 1.000 prints. To be fitted in the spare space of CityMax audio or video door entry panels for enhanced security in the home. Door controller (ref.44201) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply. Display 7 3-digit segments. Infrared receiver for programming. Number of users: - 950 in 1 person mode. - 630 in 2 fingerprint mode. The system is programmed with one fingerprint (the administrators) and with a remote infrared keypad for user authorizations/cancellations. User authorizations and cancellations can be done from a PC with the software included in the door controller (ref.44201).

Programmation

Installation
2 wires
2 wires twisted pair 2 wires
( restricted area )

Power supply

PC connection accessory (needed) ref.24661

The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.

Up to 32 Readers

PRIVATE ACCESS CONTROL

twisted pair 2 wires


( restricted area )
PRIVATE ACCESS CONTROL

2 wires
twisted pair

PC conection accessory (needed) ref.24661

twisted pair 2 wires twisted pair 2 wires twisted pair

PC Door controllers (ref.44201)

Readers

Specifications
45

43 Environmental protection (IP): 07 Protection against knocks (IK): 12Vdc Power supply (V):

Consumption (mA) without door release: 30 Operating temperature: 0 to 60C

STAND-ALONE IN NETWORK

Systems that let you approach complex installations with advanced functions and a multitude of accesses.

Centralized Access Control

CAC Central Unit


centralized

CAC Central Unit (ref.4410)


Central Unit that lets you approach complex access control installations handling up to 32 accesses or doors with a total of 2048 users. A maximum of 64 central units can be connected (2048 accesses). Includes four management softwares: CAC Data Base Server, CAC Server, CAC Access and CAC Time & Attendance. The Central Unit also monitors up to 1.000 sensors and 1.000 relays for automatic functions. Local (USB, RS-232) or remote (IP) connection to PC via the corresponding module (see accessories section).

Technical features

CENTRALIZED

Each Central Unit manages: 2.048 users. 32 accesses. 3.000 incidents (entries, exits, access denied, alerts, etc) in memory, with no need to download to PC. Managing up to 1.000 intercom panels, 1.000 sensors and 1.000 relays. The readers connectable to the Central Unit are with builtin or external controller (ref.4420).

Programmation
Power supply 12 Vdc

All programming is done with CAC software from one or several duly authorized on line or remote computers.

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

twisted pair Central Unit (ref.4410) twisted pair


( restricted area )

twisted pair Central Unit (ref.4410)


1 4 2 5 8 0 3
1
PRIVATE ACCESS CONTROL

1
2 5 8 0 3

2 5 8 0

3 6 9 B

6
4 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

........

7 A

9
7

B
A

........

7 A

Up to 32 readers 2 wires 2 wires

Up to 32 readers

( restricted area )
1 4 7 A 2 5 8 0 3 6

1 4

2 5 8

3 6 9

A
PRIVATE ACCESS CONTROL

0
1 2 5 8 0 3 6 9 B

9 B

4 7

twisted pair Reader Reader Up to 32 readers

twisted pair

Reader

Specifications
48

150 Dimensions (WxHxDmm): 175x90x40 Cons. (mA) without door release: Operating temperature: 0 to 60C Fixation: DIN rail or 2 screws to wall 12Vdc Power supply (V):

Software CAC Access


centralized

CAC Access
Needs CAC Data Base Server software installed (manages the SQL database) and CAC Server. Both included in the central unit. Software included in the Central Unit (ref.4410) to manage readers, user groups and advanced access control functions. Friendly graphic interface, simple and intuitive with a framework similar to Outlook . All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation. TCP/IP client server architecture.

Technical features
2.048 users. 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 4 special profiles without user restrictions. Special treatment for vehicles (parking areas). 32 areas. They define the doors to which access is allowed. 32 schedules. They define the periods of time when access is allowed to users. On-line record of the last 3000 incidents (entries, exits, access denied, alerts, etc). 32 weekly device activation schedules (sensors/relays). Capacity limitation in certain rooms or premises to a number of people. Door blocking/unblocking. Temporary user blocking individually or by groups. Access not permitted until they are unblocked. Option to assign timed and physical expiry of proximity cards (typical application in hotels). Automatic change of winter/summer time. Anti-pass back function, which prevents two people using the same identifier to access the facility. The doors that belong to the installation perimeter are defined and are checked to see if the user is inside or outside the perimeter when coming through them. There are two anti-passback levels associated with the same identifier, depending on how the facility is accessed, by pedestrian door or for vehicles (the type of door is defined by the CAC Control Server application). All the users may be located outside the perimeter at a set programmed time. Continuous testing of devices. Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

49

CENTRALIZED

Software CAC Time & Attendance


centralized

CAC Time & Attendance


Needs CAC Data Base Server software installed (manages the SQL database) and CAC Server. Both included in the central unit. Software included in Central Unit (ref.4410) for managing entry/exit of people, clock-ins and calculating hours worked for wages processing. Friendly graphic interface, simple and intuitive with a framework similar to Outlook . All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation.

Technical features
2048 users. 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 4 special profiles without user restrictions. 32 schedules. They define the periods of time when access is allowed to users. Vacations (20 holidays and 3 vacation periods). Record of the last 3.000 incidents (entries, exits, etc). People location control for emergency evacuations. Allocation of events in the exit readers by PIN code (doctor, commercial visit, etc). Generation of daily, weekly or monthly information: actual hours, delays, overtime, etc. Door blocking/unblocking. Temporary user blocking individually or by groups. Access not permitted until they are unblocked. Automatic change of winter/summer time. Manual change of anomalies in employee presence. Continuous testing of devices. Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

CENTRALIZED
50

Central Unit MDS


centralized

Central Unit MDS (ref.2405)


Central Unit that lets you approach complex MDS audio and video door entry systems combined with access control functions. Each Central Unit is able to manage up to 10.000 houses, 1.022 users and 31 audio or video door entry or access control panels. Can connect up to a maximum of 63 central units (approx. 2.000 accesses). Wincom+ management software included. The Central Unit also monitors up to 1.000 sensors and 1.000 relays for automatic functions. Local (USB, RS-232) or remote (IP) connection to PC via the corresponding module (see accessories section).

Technical features

Programmation
Power supply 12Vdc

All programming is done with Wincom+ software from one or several duly authorized on-line or remote computers.

Installation
Up to 64 Central Units

2 wires

2 wires

2 wires

Central Unit (ref.2405) twisted pair

twisted pair

twisted pair

................

( restricted area )

PRIVATE ACCESS CONTROL

Up to 32 elements 2 wires 2 wires twisted pair Video panel Up to 32 elements Audio panel

1 4 7 A

2 5 8 0

3 6 9 B

twisted pair Reader

51

CENTRALIZED

Each Central Unit manages: 1.022 users. 31 accesses (audio, video door entry or access control readers). 3.000 incidents (entries, exits, access denied, alerts, etc.) in memory, with no need to download to PC. Managing up to 1.000 intercom panels, 1.000 sensors and 1.000 relays. Capacity of 10 guard units. The readers connectable to the Central Unit are with builtin or external controller (ref.4420).

Wincom+ Software
centralized

Wincom+ Software
Software included in Central Unit (ref.2405) to manage complex audio, video door entry and access control installations. Management of all the parameters from a unique software with framework similar to Outlook. All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation.

Technical features
1022 users 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 32 areas. They define the doors to which access is allowed. 32 schedules. They define the periods of time when access is allowed to users. On-line record of the last 3.000 incidents (entries, exits, access denied, alerts, etc), all exportable to Excel. Vacations (20 holidays and 3 vacation periods). Installation configuration and testing. 2 user levels (administrator, operator). Lift control. Perimeter anti-passback function. Capacity limitation in certain rooms or premises to a number of people. Door blocking/unblocking. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

CENTRALIZED
52

Controller
centralized

Door Controller (ref.4420)


Door controller without memory (ref.4420). Manages the devices present in each access: up to two readers (if they are entry and exit), electric lock, door sensor and exit button. Installation indoors and separated from reader for higher security. Input Wiegand-26, magstrip or ibutton.

Technical features

Power supply 12Vdc

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Installation in mechanism box 100x100mm or surface mounted with 2 screws (included).

twisted Central Unit pair (ref.4410 o ref.2405) twisted pair Door controller ref.4420 Door controller ref.4420

twisted pair Door controller ref.4420 Door controller ref.4420

Door controller ref.4420 7 wires 7 wires 7 wires 7 wires 7 wires

( restricted area )

( restricted area )

1 4 7 A

2 5 8 0

3
PRIVATE ACCESS CONTROL
PRIVATE ACCESS CONTROL

6 9 B

Reader

Reader

Reader Up to 32 readers

Reader

Reader

Specifications

Dimensions (WxHxDmm): 85x88x25 Power supply (V): 12Vdc

Consumption: 15mA / 100mA Operating temperature: 0 to 60C

53

CENTRALIZED

Connection between controllers consists of 2 power cables and one twisted pair for data. Admits an exit and entry reader, electric lock relay, auxiliary relay for other functions, connection button, door sensor and free access. Dip switch to encode the door number, reader type and access type (pedestrian or vehicle). Necessary in vehicle accesses for connection of entrance or exit detection coils. Lets you connect any reader with Wiegand-26 input, Magstrip (Aba Track II or Dataclock). Lets you connect button key type readers Dallas i-button and matrix keypads in 8-bit burst format. Test button to check the correct installation of all devices connected to the controller.

Memokey
centralized

City Memokey MDS (ref.23291)


Access control keypad with capacity up to 100 different 4- to 6-digit codes. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module. No door controller required (ref.4420).

Technical features

Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).

CENTRALIZED

Programmation

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref. 4410).

Power supply 12 Vdc

Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair

Central Unit (ref.4410)


1 4 7 A 2 5 8 0 3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

........

4 7 A

........

4 7 A

Up to 32 readers 2 wires
1 4 7 A 2 5 8 0 3 6

Up to 32 readers

2 wires
1 4 2 5 8 3 6 9 A 0
7 8 0 9 B 1 4 2 5 3 6

9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Specifications

Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP):

Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 20 Operating temperature: 0 to 60C

54

Memokey
centralized

Bruto Memokey MDS (ref.2553)


Access control keypad with capacity up to 100 different 4- to 6-digit codes. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).

Technical features

Exit pushbutton input, door sensor input and electric lock relay. 2-wire cable for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).

Programmation

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Power supply 12 Vdc

Installation

Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair

Central Unit (ref.4410)


1 4 7 A 2 5 8 0 3 6 9 B

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

( restricted area )

........

4 7 A

........

4 7 A

PRIVATE ACCESS CONTROL

Up to 32 readers 2 wires 2 wires


1 4 7 A 2 5 8 0 3 6 9 B
PRIVATE ACCESS CONTROL

Up to 32 readers

1 4 7

2 5 8

3 6 9

A 0 B

( restricted area )

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Specifications

Dimensions (WxHxDmm): 135x130x18 Protection against knocks (IK): 09 115x100x45 Power supply (V): Flush box (included): 12Vdc Surface box (WxHxDmm): 135x131x42 Operating temperature: 0 to 60C 53 Environmental protection (IP):

55

CENTRALIZED

Memokey&Private WG
centralized

City Memokey&Private WG (ref.4480)


Dual technology access control reader: proximity and keypad. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in aluminium in City style. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply. Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

CENTRALIZED

Programmation
Power supply 12 Vdc

Installation

Up to 64 Central Units 2 wires 2 wires 2 wires

twisted pair

twisted Central Unit (ref.2405 or 4410) pair


7 wires Door controller (ref.4420)

2 wires

twisted pair

Central Unit (ref.4410)


2 5 8 0 3 6 9 B
1 4 7 A 2 5 8 0 3 6 9 B

( restricted area )

1
PRIVATE ACCESS CONTROL

2 5 8 0

3 6 9 B

4
1 4 7 A 2 5 8 0 3 6 9 B

7 A

........
7 wires

4 7 A

7 wires Up to 32 readers

7 wires 2 wires
1 4 7 A 2 5 8 0 3

Up to 32 readers

2 wires
1 2 5 8 3 6 9 A 0
7 8 0 9 B 1 4 2 5 3 6

4
9 B

Reader

twisted pair

Reader
Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 130x175x18 115x162x45 Flush box (included): Surface box (WxHxDmm): 130x175x33 Metalic box (WxHxDmm): 154x203x50 43 Environmental protection (IP):

Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30mA Operating temperature: 0 to 60C

56

Memokey&Private WG
centralized

Loft Memokey&Private WG (ref.4550)


Dual technology access control reader: proximity and keypad. Stand-alone or joint operation for higher security: PIN code + card. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for office screen profiles. Includes a 50cm cable. Door controller (ref.4420) required for operation.

Technical features

Programmation
Power supply 12 Vdc

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Installation

Up to 64 Central Units 2 wires 2 wires 2 wires

twisted pair

twisted Central Unit (ref.2405 or 4410) pair


7 wires Door controller (ref.4420)

2 wires

twisted pair

Central Unit (ref.4410)


2 5 8 0 3 6 9 B
1 4 7 A 2 5 8 0 3 6 9 B

( restricted area )

1
PRIVATE ACCESS CONTROL

2 5 8 0

3 6 9 B

4
1 4 7 A 2 5 8 0 3 6 9 B

7 A

........

4 7 A

7 wires Up to 32 readers Up to 32 readers

7 wires 2 wires
1 4 7 A 2 5 8 0 3

2 wires
1 2 5 8 3 6 9 A 0
7 8 0 9 B 1 4 2 5 3 6

4
9 B

Reader

twisted pair

Reader
Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 60x130x23 Flush box (not required): Surface box (not required): Environmental protection (IP): 66

Protection against knocks (IK): 06 Power supply (V): 12Vdc Cons. (mA) without door release: 40mA Operating temperature: 0 to 60C

57

CENTRALIZED

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.

Private
centralized

City Private MDS (ref.23351)


Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller integrated in the same module. No door controller required (ref.4420).

Technical features

Exit pushbutton input, door sensor input and electric lock relay. 2 wire cables for power supply and twisted pair for data to central unit. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier). Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

CENTRALIZED

Programmation

Power supply 12 Vdc

Installation

Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410)

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

twisted pair

( restricted area )

........

4 7 A

........

4 7 A

PRIVATE ACCESS CONTROL

Up to 32 readers 2 wires
1
( restricted area )

Up to 32 readers

2 wires
2 5 8 3 6 9 A 0
7 8 0 9 B 1 4 2 5 3 6

4
PRIVATE ACCESS CONTROL

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP):

Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 55 Operating temperature: 0 to 60C

58

Private WG
centralized

City Private WG (ref.4490)


Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply. Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Programmation
Power supply 12 Vdc

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

1 4 7

2 5 8

3 6 9

A 0 B

........

4 7 A

........

4 7 A

Door Controller (ref.4420)


7 wires
2 wires
1 ( restricted area ) 4 7 2 5 8 3 6 9 A 0 B
PRIVATE ACCESS CONTROL PRIVATE ACCESS CONTROL

Up to 32 readers 2 wires
1 4 7 A

Up to 32 readers

2 5 8 0

3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Protection environmental (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12Vdc

Cons. (mA) without door release: 30mA Temperature operating: 0 to 60C Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB

59

CENTRALIZED

Private
centralized

Bruto Private MDS (ref.2552)


Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).

Technical features

Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).

CENTRALIZED

Programmation
Power supply 12 Vdc

Programming from PC software PC corresponding to installed Central Unit (ref. 2405 or ref.4410).

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410)

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

2 5 8

3 6 9

A 0 B

twisted pair

4 7

........

4 7 A

........

4 7 A

Up to 32 readers 2 wires
1
( restricted area )

Up to 32 readers

2 wires
2 5 8 3 6 9 A 0 B
A 0 B 1 4 7 2 5 8 3 6 9

4 7

PRIVATE ACCESS CONTROL

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers Specifications

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501

Dimensions (WxHxDmm): 135x130x18 115x100x45 Flush box (included): Surface box (WxHxDmm): 135x131x42 53 Environmental protection (IP):

Protection against knocks (IK): 09 Power supply (V): 12Vdc Cons. (mA) without door release: 55 Operating temperature: 0 to 60C

60

Private WG
centralized

Bruto Private WG (ref.4510)


Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Ideal for troubled zones or districts, offices, banks, etc. Door controller (ref.4420) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply. Programming from PC software PC corresponding to installed Central Unit (ref. 2405 or ref.4410).

Programmation
Power supply 12 Vdc

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B
1 4 7 A 2 5 8 0 3 6 9 B

7 wires Door Controller (ref.4420)

4
( restricted area )

2 5 8 0

3 6 9 B

PRIVATE ACCESS CONTROL

........

7 A

........

4 7 A

Up to 32 readers 2 wires
1 4 7 2 5 8 3 6 9 A 0
7 1 4

Up to 32 readers

7 wires
2 wires
( restricted area )
PRIVATE ACCESS CONTROL

2 5 8 0

3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Identifiers

ref.23361

ref.2336

ref.2363

ref.2364

ref.44501

Specifications

Dimensions (WxHxDmm): 135x130x18 115x100x45 Flush box (included): Surface box (WxHxDmm): 135x131x42 53 Environmental protection (IP): 09 Protection against knocks (IK): 12Vdc Power supply (V):

Cons. (mA) without door release: 30 Operating temperature: 0 to 60C Reading distance (card/keyring): 4/2 cm PC Interface: RS-485/USB

61

CENTRALIZED

Private WG
centralized

Private Loft WG (ref.4560)


Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in ABS plastic. Surface mounted. Recommended for exteriors. Ideal for office screen profiles. Door controller (ref.4420) required for operation. Includes a 50 cm cable.

Technical features

CENTRALIZED

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.

Power supply 12 Vdc

Programmation Installation
2 wires

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Up to 64 Central Units 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair

Central Unit (ref.4410)

7 wires Door Controller (ref.4420)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

.........

4 7 A

........

4 7 A

Up to 32 readers
7 wires

Up to 32 readers

2 wires
1 4 7 2 5 8 3 6 9 A 0 B

2 wires
1 4 7 A 2 5 8 0 3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)

For replacement with magnetic strip.

Proximity keyring

Reader

Identifiers

ref.23361

ref.2336

ref.2336

ref.2364

ref.44501 0 to 60C 8/6 cm RS-485/USB

Specifications
62

Dimensions (WxHxDmm): 60x130x23 Environmental protection (IP): 66 Protection against knocks (IK): 06 Power supply (V): 12Vdc Cons. (mA) without door release: 40

Operating temperature: Reading distance (card/keyring): PC Interface:

Key Button
centralized

City key button MDS (ref.23261)


Access control reader whose operation is based on physical contact between the reader head (socket) and authorized identifier (plug ref.2328). Number of users: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted. Recommended for interiors and exteriors. No door controller required (ref.4420).

Technical features

Programmation
Power supply 12 Vdc

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Installation

Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410)

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

twisted pair

........

4 7 A

........

4 7 A

Up to 32 readers 2 wires
1 4 7 2 5 8 3 6 9 A 0
7

Up to 32 readers

2 wires
1 4 2 5 8 0 3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Identifiers Specifications

Key button identifier (ref.2328).


Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP): Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 25 Operating temperature: 0 to 60C

63

CENTRALIZED

Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).

Key Button WG
centralized

City key button WG (ref.2315)


Access control reader whose operation is based on physical contact between the reader head and authorized identifier (ref.2328). Number of users: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.

Technical features

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols.

CENTRALIZED

Programmation
Power supply 12 Vdc

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410) twisted pair

twisted pair

twisted pair
1 4 2 5 8 0 3 6 9 B

Central Unit (ref.4410)

7 wires Door controller (ref.4420)

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

........

........

4 7 A

Up to 32 readers 2 wires
1 4 7 2 5 8 3 6 9 A 0
7 1 4

Up to 32 readers

7 wires

2 wires
B

2 5 8 0

3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Identifiers Specifications

Key button identifier (ref.2328).


Dimensions (WxHxDmm): 130x128x18 115x114x45 Flush box (included): Surface box (WxHxDmm): 130x128x33 43 Environmental protection (IP): Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30 Operating temperature: 0 to 60C

64

Key Button
centralized

Bruto key button MDS (ref.2554)


Access control reader whose operation is based on physical contact between the reader head and authorized identifier (ref.2328). Vandal-proof panel. Manufactured in aluminium. Flush or surface mounted. Reader and controller integrated in the same module. Recommended for interiors and exteriors. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).

Technical features

Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).

Programmation
Power supply 12 Vdc

Programming from PC software corresponding to Central Unit installed (ref.2405 or ref.4410).

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref.2405 or 4410)

twisted pair

twisted pair

Central Unit (ref.4410)

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

twisted pair

........

4 7 A

........

4 7 A

Up to 32 readers 2 wires
1 4 7 2 5 8 3 6 9 A 0
7

Up to 32 readers

2 wires
1 4 2 5 8 0 3 6 9 B

Reader

twisted pair

Reader Up to 32 readers

twisted pair

Reader

Identifiers Specifications

Key button identifier (ref.2328).


Dimensions (WxHxDmm): 135x130x18 115x100x45 Flush box (included): Surface box (WxHxDmm): 135x131x42 53 Environmental protection (IP): Protection against knocks (IK): 09 Power supply (V): 12Vdc Cons. (mA) without door release: 25 Operating temperature: 0 to 60C

65

CENTRALIZED

Radiofrequency
centralized

Digital RF emitter (ref.24651)


Radio frequency emitter 433,92 MHz. Digital Technology. New and highly robust design. Dual channel emitter that can trigger two relays. Secure, unique, non configurable code exclusive series per emitter. Emitters must be authorized/cancelled in the receivers.

Technical features

Unique and exclusive code per emitter. Includes 12Vdc battery. Range: 30m. Frequency: 433,92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA
Power supply 12 Vdc

CENTRALIZED

Installation
RF emitter ref. 24651 RF Receiver ref. 1065

twisted pair

Central Unit ref.4410

Compatible with

Ref.7960 Villa Receiver (stand-alone).

Ref.1065 MDS Receiver (centralized).

Ref.2464 Secondary MDS Receiver (centralized).

Specifications

Dimensions (WxHxDmm): 53x42x12mm

66

Radiofrequency
centralized

RF Dual emitter (ref.25511)


Radio frequency emitter 433,92 MHz. Dual technology. New and highly robust design. Dual channel emitter that can trigger two relays. Secure code, unique, non configurable and exclusive as standard per emitter. Emitters must be authorized/cancelled in the receivers. Internally integrates proximity card electronics so can be used as a dual channel emitter or a substitute identifier for proximity cards or keyrings.

Technical features

In addition to the RF functions, incorporates proximity card electronics for use in proximity reader. Includes 12Vdc battery. Range: 30m. Proximity reader range: 2 cm. Frequency: 433,92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA
Power supply 12 Vdc

Installation
RF emitter ref.25511 RF receiver ref.1065

twisted pair Central Unit ref.4410

Compatible with

Ref.7960 Villa Receiver (stand-alone).

Ref.1065 MDS Receiver (centralized).

Ref.2464 Secondary MDS Receiver (centralized).

Specifications

Dimensions (WxHxDmm): 53x36x13mm

67

CENTRALIZED

Radiofrequency
centralized

MDS Receiver (ref.1065)


Single channel receiver 433.92MHz Digital Technology. When code emitted by the digital (ref.24651) or dual (ref.25511) remote control is received, the receiver closes the circuit activating the electric lock or automatic door. Mounted in watertight box (IP65) in ABS.

Technical features

Power supply 12Vdc

Includes rigid antenna, 25 cm. Optionally, by adding card (ref.7934), we can convert the receiver into dual channel. Reception frequency: 433,92 MHz. Sensitivity: 3 mV Relay contact: 2 A max. Power supply: 12Vdc Consumption: 110 mA in standby. Dip-switch to configure access number.

CENTRALIZED

Up to 64 Central Units 2 wires 2 wires 2 wires

twisted pair twisted pair Central Unit (ref.2440 or 2405)


1 4 7 A 2 5 8 0 3 6 9 B

twisted pair

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

........

4 7 A

........

4 7 A

Up to 32 readers 2 wires twisted pair Receiver Video panel Up to 32 readers 2 wires

Up to 32 readers

1 4 7 A

2 5 8 0

3 6 9 B

twisted pair Reader

Emitter RF Ref.79561

Compatible with

Digital emitters (ref.24651)

Dual emitters (ref.25511)

Specifications
68

Dimensions (WxHxDmm): 90x165x55mm

Fingerprint WG
centralized

City Fingerprint WG (ref.6990)


Fingerprint reader with thermal sensor with storage capacity: - 1.020 users with MDS central unit (ref. 2405). - 2.048 users with CAC central unit (ref.4410). Operating mode: 1 or 2 fingerprints per person. Manufactured in aluminium in new City style. Flush or surface mounted. Recommended for interiors and exteriors. Reader and controller separated. Door controller required (ref.4420).

Technical features

Power supply 12Vdc

Programmation Installation
Up to 64 Central Units

Programming from PC software corresponding to Central Unit installed (ref.2405 or ref.4410).

2 wires

2 wires

2 wires

Central Unit twisted pair (ref.2405 or ref.4410)


1 2 5 8 0 3 6 9 B

twisted pair

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

twisted pair

4 7 A

........

4 7 A

........

4 7 A

Door Controller (ref.4420)

Up to 32 readers 2 wires
1 4 7 2 5 8 3 6 9 A 0 B

Up to 32 readers

7 wires

2 wires

twisted pair Reader Video panel Up to 32 readers

twisted pair Audio panel

Specifications

Dimensions (WxHxDmm): 130x128x18 Environmental protection (IP): 43 Flush box (included): 115x114x45 Protection against knocks (IK): 07 Surface box (WxHxDmm): 130x128x33 Operating temperature: 0 to 60C

69

CENTRALIZED

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are builtin. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Programmable relay timings (monostable, bistable).

Fingerprint WG
centralized

City fingerprint module WG (ref.6989)


Fingerprint reader with thermal sensor with storage capacity: - 1.020 users with MDS central unit (ref. 2405). - 2.048 users with CAC central unit (ref.4420). Fitted in CityMax audio or video door entry system outdoor panel spare spaces for enhanced security in the home. Door controller (ref. 4420) required for operation.

Technical features

CENTRALIZED

Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Programmable relay timings (monostable, bistable).

Programmation
Power supply 12Vdc

Programming from PC software corresponding to installed Central Unit (ref. 2405 or ref. 4410).

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

The audio or video door entry panel is located on the outside. It is possible to set up a configuration in the panel intuitively including a reader (ref.6989) for greater security and more convenient access.

twisted pair Central Unit (ref.2405 or ref.4410) twisted pair

twisted pair

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

........

4 7 A

........

4 7 A

Up to 32 readers

Up to 32 readers

2 wires twisted pair Reader Video panel Up to 32 elements

2 wires twisted pair Reader

Specifications
70

43 Environmental Protection (IP): 07 Protection against knocks (IK): 12Vdc Power supply (V):

Cons. (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60C

Fingerprint Reader
centralized

Fingerprint (ref.4470)
Fingerprint reader with optical sensor and capacity to store: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Surface mounted for interiors. Door controller (ref.4420) required for operation.

Technical features

Dual technology: fingerprint and Mifare proximity card. The reader compares the fingerprint stored in the card and the sample read by the sensor. Power supply 12Vdc. 2-wire cables for power supply and twisted pair for data. One Mifare card (ref.4440) required for each user.

Programmation

Identificadores
Power supply 12Vdc

Mifare card with memory (ref.4440).

Installation
Up to 64 Central Units 2 wires 2 wires 2 wires

Central Unit (ref. 4410 or ref.2405) twisted pair

twisted pair
1 4 7 A 2 5 8 0 3 6 9 B

twisted pair

2 5 8 0

3 6 9 B

1 4 7 A

2 5 8 0

3 6 9 B

2 5 8 0

3 6 9 B

........

4 7 A

........

4 7 A

Door Controller (ref.4420) 2 wires

Up to 32 readers

Up to 32 readers

7 wires 2 wires
1 4 7 A 2 5 8 0 3 6 9 B

twisted pair Reader Video panel Up to 32 readers

twisted pair Reader

Specifications

Power supply (V):

12Vdc

71

CENTRALIZED

Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410). Card programmer (ref.4460) required to memorize fingerprint samples in the Mifare cards.

Accessories common to all systems.

Accessories

Accessories
stand-alone/stand-alone in network/centralized

Electric Lock
Device that lets you unblock the door temporarily in safe conditions: identifier accepted or opening from inside by means of the exit button. There are several models distinguished by different operating features, installation and power supply. Depending on the type of protection against electrical power cuts: Normal operation (fail secure). The door is unblocked when the electric lock is powered. As an advantage, if there is a power cut the door does not unlock. The NO (normally open) terminal is connected from the electric lock relay. Inverted operation (fail safe). The door remains blocked while the electric lock is powered. It is unlocked by cutting off the power. An advantage is that if there is a power cut, the door does not block (fire systems). According to the type of installation, there are: Electrical lock/door release. Recommended in installations where we want to combine with the traditional lock and are normally installed embedded in the door frame. When activated, releases the latch to allow the door to open. Electromagnetic door release. Usually installed when there are security requirements against fire: outward opening doors, power shutoff during the fire alarm to facilitate evacuation. They are inverted type. An iron strip is placed in the leaf of the door and an electromagnet in the frame so that when the door is closed their faces are touching. The door stays closed while the electromagnet attracts the strip. Depending on the force with of attraction, it can resist pulling or pushing to try to open the door. The force is usually measured in Kg. When there is no space in the door frame to fit the lock or if we do not want to drill it, it can be mounted on the wall with special brackets. According to the type of power supply, there are: DC current. Characterized by being quiet. Inverted operation electric locks must be this type. AC current. They are noisy compared with DC locks. They generally have a higher consumption and work better in doors subject to some type of pressure: wind, bolt friction, etc. There are door release models with a built-in door sensor to detect if the door stays open accidentally.

centralizado

n (m

ply

sor

tio

Ele eM ctric agn etic

mp

No Inv rmal ert ed

sen

rs

ting

up

ion

tem
-40 -40 -40 -40 -40 -40 a a a a a a +120C +120C +120C +120C +120C +120C

per
21x75x27 20x101x28 20x101x28 20x101x28 20x101x28 20x101x28 229x39x26 229x39x26 229x39x26 -40 a +120C -40 a +120C -40 a +120C

A)

atu

re

ref.
3071 2953 2958 29580 2967 29670 3050 3051 3052

ACCESSORIES

E E E E E E M 300Kg M 500Kg M 300Kg

N N N N I I I I I

12Vac 12Vac 12Vdc 12Vdc 12Vdc 12Vdc 12/24 Vdc

780 780 150 150 150 150 500 250 500 250 500 250

12/24 Vdc 12/24 Vdc

Squares for emagnetics door lock:

- For doors that open from inside to outside. - For doors that open from outside to inside.

ref.3077 Square for ref.3051 ref.3079 Doble square Z ref.3078 Square for ref. 3052

74

Flu Su sh rfa ce
E E E E E E E S S

ens

we

nsu

or

Dim

Co

Do

Po

Op

era

Accessories
stand-alone/stand-alone in network/centralized

Power Supplies
When choosing a suitable power supply it is necessary to consider the consumption of all the elements in the system, especially the electric lock. It is recommended to use a magneto-thermal switch not shared with any other equipment to avoid power supply disconnections caused by them. It is recommendable to use an emergency supply system (with battery) to prevent doors blocking or unblocking in the event of power cuts. In centralized installations with long distances it will be necessary to place additional power sources in the access to prevent tension drops in the wiring.

REF. 4800 POWER SUPPLY 12VAC/1,5A Recommended for stand-alone readers when we want to use AC locks. DIN4.
ref.4800

REF. 8791 EMERGENCY POWER SUPPLY 12Vac/1,5A Includes Ni-Cd battery 750mA. In emergency supplies 12Vdc. Includes Ni-Cd battery 750mA. In emergency supplies 12Vdc. REF. 4813 POWER SUPPLY 12VDC/2A General installation power supply for centralized system. REF. 2060 BATTERY ADAPTER 12VDC Installed between 12Vdc power supply and the system. With external Lead-Acid battery connection. If the input tension falls below 11Vdc it switches automatically to the battery. REF. 2070 BATTERY 12V/2,2A Lead-Acid battery without maintenance for small installations or an access power supply. REF. 2337 BATTERY 12V/ 7A Lead-Acid battery without maintenance for large installations.

ref. 4813

ref.2060

75

ACCESSORIES

Accessories
stand-alone/stand-alone in network/centralized

Door Sensor
REF. 1076 MAGNETIC CONTACT Surface installation between door and frame. Connected to the door sensor input of the controllers.

Power Cutoff
REF. 4475 POWER CUTOFF Lets you disconnect the electrical current to the devices in a room when the user is not in. For connection, it is necessary to introduce the user proximity card in the cutoff (only works with proximity cards). When the user leaves the room they remove the card from the cutoff and then have 10 seconds courtesy to leave the room. Designed to be used as a complement to the stand-alone or centralized proximity readers, since the same cards are used. The user is obliged to remove the card from the cutoff; otherwise they will not be able to open the door of the room. Embedded installation in mechanism box 60x70mm. Operating at 230V. Cutoff power: 6000W.

centralizado

Proximity technology: EM, TEMIC, RF256 and TK cards.

Desktop Proximity Reader


Lets you authorize proximity identifiers quickly and easily by PC with management software. PC connection: RS-232. Cable included. Power supply 230Vac by adaptor (included).
230Vac power supply

ACCESSORIES

3 RS-232 ref.2349

installation

76

Accessories
stand-alone in network/centralized

PC Management Modules
The system operating mode configuration, user authorizations and cancellations and restrictions are handled via PC and sent to the central unit so that it works independently. The information generated by the installation (events) must be communicated to the PC in real time. To set up these communications, the PC must be connected to the central unit. The connection can be made locally or remotely, using one of the following devices:

Adaptor RS-232 to RS-485 (ref.2338)


Connection between PC and central unit (or network of CUs). Also lets you connect the modem to the central unit for remote management. PC connection: RS-232 max. 30 mts. (cable 3 mtrs included). Connection to central: RS-485 (twisted pair). Max. 1200 mts. DIN6 format (surface mounted and DIN rail). Power supply 230Vac.

Adaptor RS-232 to RS-485 (ref.2466)


Programming of addresses and parameters to decoders from the PC. Used for maintenance of facilities that do not have the PC permanently connected, as an installer tool. Includes an RS-232 cable with DB-9 connector for PC connection.

ref. 2466 3 RS-232

ref.2338

2 twisted pair

230 Vac 2 3 RS-232 twisted pair 2 RS-485

IP Adaptor (ref.1087)
Communication between management PC and the installation using IT network (Ethernet), avoiding additional wiring. Connection to central unit by programmer (ref. 2466). An IP address must be configured to connect to the network using the software included. Remote management via Internet if the protection devices (Firewall) in the IT installation allow it (specialized personnel required to configure router for Internet access).

Adaptor USB to RS-485 (ref.24661)


Connection between PC (USB) and central unit. Direct power supply from USB. Includes driver.

Power supply 230Vac by adaptor included. Ethernet connection RJ45.

ref.1087 ref. 2466 3 RS-232 Ref.24661 2 RS-485 twisted pair USB PC twisted pair 2 RJ-45 IP PC RJ-45

77

ACCESORIES

Accessories
centralized

Technical Alarms and Automation


Several sensors may be connected to the installation (up to 1000) to carry out automated activities based on the source of the detection. The sensors must be potential free contact, such as switches, pushbuttons, magnetic contacts, volumetric detectors, photoelectric barriers, etc. These sensors are managed by 'sensor decoders, with capacity for 8 entrances, and connected to the central unit by the decoder bus, from which it is powered. NA or NC operating mode and the type of trigger (instant or delay up to 127 minutes) must be configured. For each group (100 sensors), the actions to take are indicated (not exclusive): Communicate the incident to the central console (security post). Activate one or several relays (ref. 2430) (always the same or different depending on the sensor). Switch status of a relay. Monitor the incident on the control computer (control post). Activate the electric lock of a given door. Subordinate the action to the simultaneous activation of another sensor (double signalling to avoid false alarms). Sensors can be enabled and disabled during a set schedule by means of the schedule planner or from the access control readers, when a user identifier associated with a sensor is presented. The most frequent applications of the sensors are the following: Technical alarms: Alarm messages in the PC control. Power failure, water leak, intrusion, etc... Construction of pushbutton panels for timed activation of devices: vehicle barriers, opening doors, hallway lighting, etc. Door blocking depending on the status of other doors.

centralizado

SENSOR DECODER ref.2429

In the installation it is possible to connect up to 1000 relays in the same decoder bus, to activate different devices in response to the activation of sensors or trigger them independently. The relays are implemented by 'relay decoder' containing 8 2 Amp. relays with NA and NC output. The relay decoder connects to the decoder bus, which powers it. For each output, timing (1 to 255 seconds or indefinite) and the initial status (active or standby) are configured.

ACCESSORIES

RELAY DECODER ref.2430

78

There are several ways to trigger the relays: Schedule planner: activates and deactivates relays according to a set weekly schedule (up to 32 daily plans). From the access control readers. Each user can have a relay associate with their identifier so that when it is presented, the associated relay status is switched while activating the door release. From the central guard - unit. Any relay can be activated or deactivated by entering its number and the desired status (active / standby). When a sensor or combination of sensors is activated. When the maximum capacity of a zone is reached. When there is someone in a zone.

Typical applications are: Automatic connection and disconnection of devices: heating, refrigeration, lighting, etc. Alarms connection and disconnection. Activation of sirens and warning lights. Unblocking of doors during a set schedule.

Specifications
Programming the sensor and relay decoders is done with the decoder programmer (ref. 2466).
SENSOR DECODER
Dimensions (WxHxDmm): N devices Maximum capacity/central Activation type Prog. detection/activation Detection/activation. Power supply Consumption (mA) min/max. Temperature operating: 175x90x37 8 inputs 1000 Potential free contact 26 sec. 1sec./127 min. 10 -10C to +60C 2 A NC/NA 1 sec. 1..255 sec./indefinite 12Vdc 7/170 -10C to +60C

RELAY DECODER
175x90x37 8 outputs

Desktop guard unit


Can recieve calls from the interphone panels and allow access to visitors. Permits access management of any door within the installation. Receives sensor reports in the case of manipulated or open doors. In installations with several guard units all calls and alarms can be centralized in one main guard unit. To be connected to the door bus by means of two additional wires for the audio (ref.5918). From the main guard unit a simple user configuration can be done (without restrictions), no PC configuration necessary.
PANEL DECODER
Dimensions (WxHxDmm): Power supply: Consumption (mA) min/max.: Operating temperature: 175x90x37 12 Vdc 15/30 -10C to +60C

ref.2537

MAIN GUARD UNIT


215x205x250 12 Vdc 300 -10C to +60C
ref.5918

79

ACCESSORIES

Index of references
REF.
01065 01087 02013 02060 02070 02133 02260 02263 02268 02288 02306 02315 02328 02336 02337 02338 02347 02349 02351 02363 02405 02429 02430 02464 02466 02520 02523 02552 02553 02554 02560 02561 02778 02953 02958 02967 03050 03051 03052 03071 03077 03078 03079

DESCRIPTION
RF MDS RECEIVER REMOTE MANAGEMENT IP MODULE RELAY STAIRS LIGHT EMERGENCY BATTERY MODULE 12V EMERGENCY BATTERY 12V-2 A. BRUTO KIT MEMOKEY STAND-ALONE CITY KIT PRIVATE STAND-ALONE CITY PROXIMITY READER STAND-ALONE MODULE BRUTO PROXIMITY MDS MODULE BRUTO PROXIMITY READER STAND-ALONE MODULE PROGRAMMATION KEYPAD PRIVATE READER KEY-BUTTON READER WG KEY BUTTON IDENTIFICATOR PROXIMITY CARD WITH MAGNETIC STRIPE BATTERY 12VDC.6,5AMP DIN TERMINAL DIG.FX-L 220V CITY PRIVATE READER STAND-ALONE CITY PRIVATE READER DESKTOP PROGRAMMING KIT WINPROX PROXIMITY CARD WITHOUT MAGNETIC STRIPE CENTRAL UNIT MDS DECODER OF 8 SENSORS MDS DECODER OF 8 RELAYS MDS SECUNDARY RF RECEIVER PC INTERFACE DECODER CITYMAX MEMOKEY MODULE BRUTO MEMOKEY MODULE BRUTO PROXIMITY READER MDS BRUTO MDS DIGITAL KEYPAD BRUTO KEY-BUTTON READER MDS CITY PROXIMITY MDS MODULE CITY KEYPAD MDS MODULE BRUTO 1 SURFACE BOX MODULE DOOR LOCK MOD.3000N-S DOOR LOCK N-412-S DOOR LOCK N-512-S FLUSH EMAGNETIC DOOR LOCK 300Kg EMAGNETIC SURFACE DOOR LOCK 500Kg EMAGNETIC SURFACE DOOR LOCK 300Kg UNIVERSAL MOD.450N-S DOOR LOCK SQUARE L-2 FOR REF.3051 SQUARE L-3 FOR REF.3052 DOUBLE SQUARE

80

Index of references
REF.
03591 03491 03600 03610 03619 03620 03621 03623 03624 04410 04420 04440 04460 04470 04475 04476 04477 04478 04480 04490 04500 04510 04520 04530 04540 04550 04560 04642 04698 04699 04800 04810 04813 06988 06989 06990 07900 07903 07910 07911 07912 07952 07960

DESCRIPTION
CITY MEMOKEY CR 230V KIT DIN RAIL 12 VDC 12A RELAY KIT MEMOKEY CITY STAND-ALONE CITY MEMOKEY READER STAND-ALONE CITY PRIVATE KIT WITH PROXIMITY KEYRINGS CR MEMOKEY 100 CODES KEYPAD CR MEMOKEY 100C. CONTROLLER LOFT MEMOKEY STAND-ALONE KIT KIT PRIVATE LOFT STAND-ALONE CAC CENTRAL UNIT DOOR CONTROLLER WITHOUT MEMORY MIFARE PROXIMITY CARD FINGERPRINT PROGRAMMER FINGERPRINT READER ENERGY CUTOFF CITYMAX BLUETOOTH MODULE CITY BLUETOOTH READER BLUETOOTH READER KIT CITY MEMOKEY/PROXIMITY WG CITY PROXIMITY READER WG BRUTO MEMOKEY MODULE BRUTO PROXIMITY READER WG BRUTO 1 PRIVATE MODULE LOFT PROXIMITY READER STAND-ALONE LOFT MEMOKEY READER STAND-ALONE LOFT MEMOKEY/PRIVATE READER WG LOFT PRIVATE READER WG MARINE FLUSH BOX ST-2 MARINE PROXIMITY READER MODULE STAND-ALONE MARINE MEMOKEY KEYPAD POWER SUPPLY 12VAC/1,5A POWER SUPPLY DIN10 230VAC/12VAC+18VDC-1.5A POWER SUPPLY 12VDC/2A CITY FINGERPRINT READER KIT CITY FINGERPRINT MODULER READER CITY FINGERPRINT READER SINGLE CHANNEL 433Mhz RF RECEIVER RF RECEIVER FOR SHOPS 433Mhz - 230 V RADIOFRECUENCY FOR SHOPS KIT STANDARD RADIOFRECUENCY KIT SECURITY RADIOFRECUENCY KIT RF RECEIVER FOR GARAGES RF VILLA RECEIVER

81

Index of references
REF.
08791 08851 22371 23261 23291 23351 23361 24651 24661 25511 29518 29628 44201 44501 79561

DESCRIPTION
EMERGENCY POWER SUPPLY 12VAC/1,5A CITY SUPERFACE BOX SERIES 1 BRUTO KEYPAD MDS MODULE MDS KEY BUTTON READER CITY MEMOKEY READER MDS CITY PRIVATE READER MDS STANDARD PROXIMITY CARD WITHOUT MAGNETIC STRIPE RF SEGURITY EMITTER USB CONVERTER RF DUAL EMITTER DOOR LOCK AD-2005 DOOR LOCK MOD.N-424-S MAX DOOR CONTROLLER WITH MEMORY PROXIMITY KEYRING RF TRINARY EMITTER

82

A C C ES S C ON TRO L 1 Edi t i on . M a rc h 2 0 0 9
st

Audio and Video Door Entry Systems www.fermax.com export@fermax.com


PU00430