UPS-Systems
Device Designation Rated output power EVD-MIN 0.7-3 kVA 0.7 1.0 1.5 2.0 3.0 kVA EVD-MIN 4.5-6 kVA 4.5 6.0 kVA EVD-MID 6.5 20 kVA 6.5 - 8 - 10 12 15 20 kVA
Input Voltage Frequency Power factor Softstart Intermediate circuit Voltage Charging current Output Voltage Wave Form Frequency Crest factor Harmonic distortion Overloadable By-Pass Displacement factor cos Phi Efficiency Output power Autonomy time General data Environmental conditions Ambient temperature Altitude Colour Humidity Protection class Noise level Standards 0-40C max. 3000m above sea level black up to max. 90% IP 20 <50 dBA CE, UL, EN62040-1-1, IEC60950-1, EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A, ISO9001, EN62040-3 0-40C max. 3000m above sea level black up to max. 90% IP 20 <50 dBA CE, UL, EN62040-1-1, UL 1778, EN62040-2, EN61000-3-3, FCC Class A, ISO9001, EN62040-3, EN 61000-4-5 0-40C max. 1000m above sea level (rated power) RAL 7024 (dark grey) up to max. 90% IP 20 <52 dBA CE, EN62040-1-1, Directive 73/23/EEC, 93/68/EEC, EN62040-2 Cl. 2, Directive 2004/108/EEC, 93/68/EEC, 89/336/ EEC, IEC801-5 (2.2kV/1.2-50s), ISO9001, EN62040-3 Display and user interface Options RS232, UPSilon 2000 with cable Com Slot for 2. RS-232 or SNMP or relay card, galvic isolation transformer, single control output socket Dimensions (W x H x D) 0.7-1kVA: 88 x440x405mm 1.5-3kVA: 88x440x650mm (as tower UPS without transformer)
Right to make technical changes reserved
3 x 380 / 400 / 415VAC (three phase with N) 20% 220 / 230 / 240VAC (one phase with N) 20% 50-60Hz 0.99 30 sec.
240VDC 2A
480VDC 6A
200 / 208 / 220 / 230 / 240 VAC 1% sinusoidal 50 / 60 Hz 1% 3:1 (without transformer) 2.5:1 (with transformer) < 3% up to 120% 30 sec. up to 150% 10 sec. static switch CosPhi 0.7 ind. > 85% 0.7 3 kVA (0.49 2.1 kW) upon request
200 / 208 / 220 / 230 / 240 VAC 2% sinusoidal 50 / 60 Hz 1% 3:1 < 3% up to 150% 160 sec. static switch CosPhi 0.7 ind. 90%, ECO mode 95% 4.5 6 kVA (3.15 - 4.2 kW) upon request
220 / 230 / 240V with N sinusoidal 50 / 60 Hz 0.1% 3:1 1% with linear load, 3% with distorting load 110% 10min. / 150% 5 sec. static switch CosPhi 0.8 ind. up to cosPhi 0.9 cap. 94% 10 20 kVA (8 16 kW) upon request
RS232, UPSilon2000 with cable Com Slot for 2. RS-232 or SNMP or relay card, galvanic isolation transformer, up to 4 UPS systems in parallel 176x440x680mm (as tower UPS without transformer)
RS232, Multilink CD, communication software, connection cable SNMP adapter, Modbus, Profibus, remote signalling, Shutdown-Software 840 x 930 x 320mm
UPS-Systems
Device Designation Rated output power EVD-MAX 10 80 kVA 10 15 20 30 40 60 80 kVA EVD-MAX 100-800 kVA 100 120 160 200 250 300 400 500 600 800 kVA Input Voltage Frequency Power factor Softstart Intermediate circuit Voltage Charging current Output Voltage Wave Form Frequency Crest factor Harmonic distortion Overloadable By-Pass Displacement factor cos Phi Efficiency Output power Autonomy time General data Environmental conditions Ambient temperature Altitude Colour Humidity Protection class Noise level Standards 040C max. 1000m above sea level (rated power) RAL 7035 up to max. 95% IP 20 54 62 dBA CE, EN50091-1, EN50091-2, EN61000 4/5, ISO9001, EN62040-3 Display and user interface Options LC Display, RS232, potential free dry contacts, automatic battery test parallel operation, remote signalling, battery cabinet, communication software, battery extension, 12-pulse converter, central battery (parallel operation) Dimensions (W x H x D) EVD-MAX 10-40: 555 x 1200 x 720mm EVD-MAX 60-80: 1070 x 1400 x 740mm LC Display, RS232, potential free dry contacts, automatic battery test parallel operation, remote signalling, battery cabinet, communication software, battery extension, 12-pulse converter, THDi-filter, central battery (parallel operation) EVD-MAX 100: 1070 x 1900 x 800mm EVD-MAX 120-200: 1200 x 1900 x 800mm EVD-MAX 250-300: 1630 x 1900 x 850mm EVD-MAX 400: 1630 x 1900 x 1000mm EVD-MAX 500-600: 3200 x 1900 x 1000mm EVD-MAX 800: 4400 x 1900 x 1000mm
Right to make technical changes reserved
AMP 10-250 kVA 10 15 20 25 - 30 40 50 60 - 80 100 - 120 150 160 200 - 250 kVA
3 x 400 VAC (three phase with N) 20% 50-60 Hz 0.83 (0.9 with filter) 30 sec.
3 x 380 / 400 / 415 VAC (three phase with N)) 45-65 Hz 0.95 - 0.99 30 sec.
3 x 380 / 220 with N, 3 x 400 / 230 with N, 3 x 415 / 240 with N 35-70 Hz 0.99 30 sec.
3 x 380 / 400 / 415VAC (three phase with N) 1% sinusoidal 50 / 60 Hz 1% 3:1 2% with linear load, 5% with distorting load 110% 5 h / 125% 10min. / 150% 1min. / 200% 7 sec. static switch / manual CosPhi 0.8 ind. 92% 10 80 kVA (8 64 kW) upon request
3 x 380 / 400 / 415VAC (three phase with N) 1% sinusoidal 50 / 60 Hz 1% 3:1 <1 % with linear load 110% 60min. / 125% 10min. / 150% 1min. / 200% 7 sec. static switch / manual CosPhi 0.8 ind. up to 0.9 cap. 94% 100 800 kVA (80 640 kW) upon request
3 x 380 / 220 with N, 3 x 400 / 230 with N, 3 x 415 / 240 with N sinusoidal 50 / 60 Hz 3:1 2% with linear load, 4% with distorting load 125% 10min. / 150% 1min. static switch / manual CosPhi 0.8 ind. up to 0.9 cap. 96% 10 250 kVA (8 200 kW) upon request
040C max. 1000m above sea level (rated power) RAL 7035 up to max. 95% IP 20 63 78 dBA CE, ISO9001, EN62040-1, EN62040-2, EN62040-3
040C max. 1000m above sea level (rated power) Front: RAL 9007, side walls: Graffito grey up to max. 95% IP 20 55 - 65 dBA CE, GOST through TV, ISO9001, EN62040-1-1, EN60950-1, EN62040-2, EN61000-3-3, EN61000-6-2, EN61000-6-4, EN62040-3 LC Display (PMD) for each unit, RS232, 10 potential free dry contacts Additional slot for COM-Cards (SNMP, Elvawatch)