Anda di halaman 1dari 3
PT. GEOSERVICES VKAN COAL LABORATORY DIVISION Konan teee www.geoservices.co.id Menta: hone 2156 672157 Ree) Sst ligapan rit done REPORT OF ANALYSIS Page 1 of 3 REPORT NO 2 00119.01023 CUSTOMER : PT. PUTRA DEWA JAYA REPORT ON : ANALYSIS OF ONE (01) COAL SAMPLE IDENTIFIED AS " P&J" SUBMITTED REPORT TO : MR. H. ODANG PT. PUTRA DEWA JAYA Jalan Mulawarman RT. 47 AUTHORISATION —:_Letter request from Mr. H. Odang Dated : October 23, 2019 DATEREPORTED =: October 25, 2019 (ORIGINAL Deputy Labolftory Manager This report shall not be reproduced except in full without the written approval ofthe testing laboratory (Laporan ii tidak boleh direproduksi schagian tanpa izi tertuls dari laboratorivm pengoii) PT. GEOSERVICES COAL LABORATORY DIVISION Jl. MT. Haryono No.161 Ring Road Balikpapan, Kalimantan Timur - Indonesia Telp : (0542) 872152, 872155, 872156, 872157 Fax :(0542) 872151. www.geoservices.co.id PT. PUTRA DEWA JAYA. ReportNo —: 00119.01023 Date :25/10/2019 Page 2 of 3 1. SAMPLE. This report details the testing and analysis of one (01) coal sample that was submitted to PT. Geoservices Balikpapan laboratory on October 23, 2019. The samples was received in bag which was good packed ‘Sampling was performed by PT. Putra Dewa Jaya or their agent. 2, ANALYSIS ‘Sample was analysed for the following quality characteristics as requested by Mr. H. Odang, dated : October 23, 2019. The standard method used is appended below ° Total Moisture in coal % ar ASTM D 3302-2017 ° Moisture in the analysis sample % adb ASTM D 3173-2017 ° Ash in the analysis sample % adb ASTM D 3174-2012 ° Volatile Matter in the analysis sample % adb ASTM D 3175-2017 ° Sulfur in the analysis sample % adb ASTM D 4239-2014 ° Gross Calorific Value Keal/kg adb,ar,daf ASTM D 5865-2013 ar as received adb air dried basis daf —_dryash free basis ASTM American Society for Testing and Materials All analysis were carried out in duplicate at PT. Geoservices Ba} Laboratory. 3. RESULTS 2 of The samples was prepared on October 23, 2019 and completed anal on October 24, 2019. The results of testing and analysis are presented on the following page. I/not be reproduced exc inital PT. GEOSERVICES COAL LABORATORY DIVISION eae Jl. MT. Haryono No.161 Ring Road Balikpapan, Kalimantan Timur - Indonesia Telp : (0542) 872152, 872155, 872156, 872157 Fax :(0542) 872151. www.geoservices. PT. PUTRA DEWA JAYA Report No: 00119.01023 Date :25/1012019 Standard Method : ASTM Page 3 of 3 ‘Customer sample ID : Lab sample ID No. Mass Received gram 10935.0 Total Moisture in coal % ar 492 Moisture in the analysis sample % adb 1.51 Ash in the analysis sample % adb 870 Volatile Matter in the analysis sample | % adb 34.08 Fixed Carbon by difference % adb 58.71 Sulfur in the analysis sample % adb 347 Gross Calorific Value Kcalhkg adb 7425 Gross Calorific Value Keallkg ar 7168 Gross Calorific Value Kealleg dat 6269 ‘Sampling was performed by PT. Pulra Dewa Jaya or their agent Deputy Labofatory Manager This report shall not be reproduced except in Tull without the written approval of the testing laboratory @ idak boleh direproduksi sebay ulis dari laboratoriuem

Anda mungkin juga menyukai