2010
www.maretron.com
Contents
2010 PRODUCT
PC Software/Interfacing Displays & Alarms Navigation Instruments Engine/Vessel Monitoring Cables and Connectors Network Installation Guide
CATALOG
Maretron designs, manufactures and markets leadingedge networked electronics for the marine marketplace. Maretrons products are designed to the open industry NMEA 2000 standard, which allows electronic equipment from diverse manufacturers to be networked together for sharing information throughout the vessel. Maretrons corporate philosophy is to provide premium quality, state-of-the-art marine electronics that work in conjunction with traditional navigation techniques for the highest level of safety and performance while boating.
866-550-9100
Maretrons USB100 is a gateway for bridging USB equipped computers with the NMEA 2000 network so you can continue to use PC-based navigation software or you can view critical vessel systems using Maretrons vessel monitoring software (N2KView).
The NMEA 2000 standard is a serial data communications network for interconnecting marine electronic equipment where all data is transferred over a single network cable. Maretron is leading the way by introducing the first NMEA 2000 Approved connectors and cables.
Maretrons DST100 Smart Retractable Depth/ Speed/Temperature Transducer delivers precise digital depth, accurate speed and exact water temperature even at speeds above 40 knots. Maretrons TLA100 is used to adapt commercially available resistive tank senders to the NMEA 2000 network. This allows you to observe tank levels anywhere on the vessel where there is an NMEA 2000 compatible display such as the Maretron DSM200 or DSM250.
www.maretron.com
Maretrons color (DSM250) display is a 5.7 easy to use display for monitoring any or all NMEA 2000 network data including engine gauges, navigational information, environmental data, tank levels, and much more.
Maretrons SSC200 is a solid state rate gyro compass with no moving parts and, unlike a flux gate compass that sloshes around during turns or pitching seaways, the SSC200 continues to provide accurate heading information. The result is increased fuel economy and reduced wear and tear on your autopilot since S-turning about the desired course is reduced.
Maretrons WSO100 is an ultrasonic wind and weather station that measures wind speed and direction, air temperature, barometric pressure, and relative humidity. The wind measurement is performed using ultrasonic sensors, which means there are no moving parts to wear out or to get caught in the rigging.
Maretrons GPS200 is a global positioning system antenna/ receiver that incorporates the latest WAAS technology for accurate position fixes. The GPS200 connects directly to an NMEA 2000 network and communicates with navigational software, chart plotters, autopilots and dedicated instrument displays and its compact, waterproof housing provides years of reliable performance.
Radar GPS
Computer
Compass
Depth/Speed/Temperature Transducer
Maretron products include engine monitors for converting newer digital engine data as well as analog engine data to an NMEA 2000 format so the data can be observed anywhere on the vessel with any NMEA 2000 compatible display.
Network topology includes simple tee connections (or drops) where devices can be connected or disconnected from the trunk line under power without disturbing the rest of the network.
Single network cable provides power as well as communication signals which eliminates the need for separate power connections.
Maretrons RAA100 is used to adapt commercially available resistive rudder angle senders to the NMEA 2000 network. This allows you to observe rudder angle anywhere on the vessel where there is an NMEA 2000 compatible display such as the Maretron DSM200 or DSM250.
Cable connector ends are nickel-plated brass to withstand the harsh marine environment and are keyed for error-free connections. Screw thread connector ends reduce chances of accidental disconnects of essential equipment. All connections are waterproof and continue to work even while they are submerged in the bilge.
PC Software/ Interfacing
N2KView USB100
Maretron brings world-class vessel monitoring systems to the PC using state of the art networking technology. Now you can monitor all critical vessel systems including engines, gensets, tanks, rudder, navigation instruments, local weather, electrical systems and more, all using an open industry standard for true plug-and-play compatibility.
Maretrons vessel monitoring and control* software (N2KView) provides unprecedented access to all your vessels systems through multiple configurable screens. *Control refers to specific electrical distributed power systems that are based on NMEA 2000 networking.
Maretrons USB gateway (USB100) bridges the gap between an NMEA 2000 network and a PC using one simple USB connection.
N2KView
Vessel Monitoring and Control Software
N2KView is completely user-configurable and you are free to design different screens to your exact needs while easily switching from screen to screen for monitoring all your systems. Digital displays, analog gauges, graphic displays, warning lights, bar graphs, all can be configured exactly how you want them to be. You can even set the operating limits and color bands for analog gauges so you know when things are within limits and when they are not. Once you connect a PC to the NMEA 2000 network using the Maretron USB100 gateway, you can connect other PCs or handhelds using conventional technology like Ethernet or Wi-Fi for remote viewing of things like tank levels up on deck while fueling, or for monitoring the vessels location anywhere in the world using an Internet connection back to the boat.
Whether you are interested in monitoring your vessels systems while underway or remotely from your home or office, Maretrons N2KView software displays the information you need including engines, gensets, tanks, rudders, navigation instruments, local weather, electrical systems and more.
Engine View
www.maretron.com 1-866-550-9100
Value
Windows XP Home Edition/Professional Vista Pentium 4 or Equivalent Pentium 4, (3.0 GHz) 512 MB RAM 1 GB RAM 40 MB Single 128 MB 256 MB Two USB Ports 1.1 or 2.0 Compatible 1024x768 Resolution, 32-bit Color Video Dedicated Video Cards 64 MB RAM per NMEA 2000 Standard Approved
Comment
Latest Service Pack may be Required for Support Latest Service Pack may be Required for Support
Products
One Port for Software License Key, One for Maretron Gateway
DESCRIPTION N2KView Basic Software N2KView Basic Software (Additional Station) N2KView Platinum Software N2KView Platinum Software (Additional Station)
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
USB100
NMEA 2000
USB Gateway
Maretrons USB100 is a gateway for bridging computers to an NMEA network. This allows you to use PC based vessel monitoring and control software like Maretrons N2KView or PC based navigation software. The gateway provides one simple connection between the network and the PC, which eliminates conventional multiplexers and the maze of wires usually associated with interfacing equipment to PCs. For older PC based navigation software that requires receiving data in NMEA 0183 format, the USB100 automatically converts information from the NMEA 2000 network to NMEA 0183 sentences. You can continue benefiting from navigational and charting software that you already own while enjoying the many benefits of networked NMEA 2000 instruments.
Maretrons USB100 gateway bridges the gap between NMEA 2000 networks and PCs equipped with a USB port. You can continue benefiting from navigational and charting software that you already own while enjoying the many benefits of networked instruments.
Products
PART NUMBER USB100-01 DESCRIPTION Gateway NMEA 2000 / USB
10
www.maretron.com 1-866-550-9100
Specifications
Parameter
NMEA 2000 Connector NMEA 2000 / USB Isolation USB Standard USB Connector USB Supported Signals USB Auxiliary Power USB Baud Rate
Value
DeviceNet Micro-C Opto-Isolated USB 1.1 USB Type B D+, D-, +5V, GND +5 Volts < 50 mA Up to 12 Mb/s NMEA 0183 Native NMEA 2000
62.23mm 2.45
Comment
Industry Standard Waterproof No Electrical Connection Across Bridge Industry Standard Waterproof Bi-directional Gateway Full Speed USB Data Rate With Maretron-Supplied Windows Drivers With Maretron-Supplied API
35mm 1.38
62.23mm 2.45
Standard
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
88mm 3.46
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
76.2mm 3.0
88mm 3.46
Type
Voltage, Current, Temperature
Data Types
Battery Monitor
Compass
Depth
Engine GPS
79mm 3.11
Rudder Indicator
Speed Weather Station
Wind
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts < 150mA 3
35mm Yes 1.38
Comment
DC Voltage Average Current Drain NMEA 2000 Spec. (1 LEN = 50mA) Indefinitely Energy Rated Per SAE J1113
35mm 1.38
Yes
Mechanical
Parameter
Size Weight
62.23mm 2.45
Value
3.11 x 3.46 x 1.38 (79mm x 88mm x 35mm) 8 oz. (227 g)
Comment
Including Flanges for Mounting
Parameter
IEC 60945 Classification
Value
Exposed IP67 -25C to 55C
88mm 3.46
Environmental
Storage Temperature Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Immunity Safety Precautions
79mm 3.11
2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
11
Maretron offers a multi-function color display that can be used at multiple locations throughout the vessel. The universal display delivers the information you need, when and where you need it. The DSM250 is a high-resolution LCD screen that is readable in bright sunlight and waterproof to IP67 rating. It displays provide a wide array of information including AC power, battery, depth, engine, environment, fuel management, GPS, heading, navigation, rudder, speed, tanks, time, transmission, weather, wind and more. Maretrons DSM250 is completely user configurable and you can scroll from screen to screen automatically or with a single push of a button. Pictured to the right are just a few of the many possible screen configurations. Also provided as a user interface to the NMEA 2000 network is the Maretron alarm buzzer (ALM100). A super loud buzzer for alerting you to alarm conditions. The buzzer is waterproof so it can be mounted outdoors as well as indoors, and it includes a baffle to reduce noise in confined spaces.
12
Course Up Heading
GPS Status
Moon Phase
Quad Numeric
Rolling Road
Swing Meter
Rudder Angle
Single Tachometer
Trim Tabs
Tri-Display
Local Weather
DSM250
Maretrons DSM250 is a high-resolution sunlight viewable color display that allows easy interpretation of NMEA 2000 instrument and navigation data through custom display configurations, featuring an easy-to-use five-key illuminated keypad. Unlike traditional single-display units, DSM250 users can choose numeric, gauge, or graph formats in single or multiple displays, with cycling options possible for a wide range of favorite data. These multiple display options conserve mounting space and reduce overall system cost. The DSM250 will directly connect with any NMEA 2000 network and display any or all information captured throughout the vessel. Various audio and visual alarms are also programmable. The DSM250 displays a multitude of information including AC power, battery, depth, engine, environment, fuel management, GPS, heading, navigation, rudder, speed, tanks, time, transmission, weather, wind and more. Maretrons DSM250 is engineered and manufactured to the highest standards (IEC 60945 Maritime Navigation and Radio communication Equipment). Its compact waterproof housing will provide years of reliable performance. The DSM250 is available in three different color cases: black, gray, or white.
Products
PART NUMBER DSM250-01 DSM250-02 DSM250-03 DSMMNTASSBLY DSM250CVR2PK-01 DSM250CVR2PK-02 DSM250CVR2PK-03 DESCRIPTION High Bright Color Display (Black Enclosure) High Bright Color Display (Gray Enclosure) High Bright Color Display (White Enclosure) DSM200/DSM250 Gimbal Mount Package of (2) Black DSM250 Covers Package of (2) Gray DSM250 Covers Package of (2) White DSM250 Covers
14
www.maretron.com 1-866-550-9100
Specifications
Parameter
NMEA 2000 Connector Display Technology Display Resolution Display Viewable Area Display Backlighting Keyboard Languages Supported
Value
DeviceNet Micro-C Active Matrix TFT LCD 320 x 240 Pixels 117mm W x 88mm H CCFL 5 Silicone Rubber Keys English, Dutch (Nederlands)
Comment
Industry Standard Waterproof Sunlight Readable QVGA Resolution 5.7 Diagonal 3-User-Programmed Levels 0-100% Multi-Colored LED Backlighting User Selectable
Certifications
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
Instrument Type
AC Power
Data Types
Voltage, Current, Frequency, Line-Neutral Voltage, Line-Line Voltage, Real Power, Reactive Power, Apparent Power, Power Factor, kWH Import, kWH Export Voltage, Current, Temperature, State of Charge, State of Health, Time Remaining, Ripple Voltage, Power
Water Depth, Transducer Offset Tach., Eng. Hrs., Oil, Coolant, Boost & Fuel Pres., Voltage, Oil & Coolant Temp., Fuel Rate, Tilt/Trim
Battery
Depth Engine Monitor
Environment
Fuel Management
GPS Heading Navigation Rudder Indicator Speed Tank Monitor Time Transmission Trim Tabs Wind
Barometer, Heat Index, Hum. Inside & Outside, Moon Phase, Sunrise, Sunset, Temp. Dew Point, Temp. Eng. Room, Temp. Inside, Temp. Sea, Twilight AM & PM, Wind Chill
Total Fuel Rate,Total Fuel Economy, Total Fuel Remaining
COG, SOG, DOP, Position, Satellites, Time Heading, Rate of Turn, Variation BOD, Drift, Set, XTE, TTG, ETA, VMG, DTW, BTW, Rolling Road, Datum, Waypoint Number & Name, COG, SOG Rudder Position and Order Through Water, Over Ground, Total Log, Trip Log Capacity, Level, Remaining Date Local, Date UTC, Time Local, Time UTC Gear, Oil Pressure, Oil Temperature Bar Graph Apparent Direction and Speed, True Direction and Speed, Ground Direction and Speed
Parameter
Value
9 to 32 Volts < 650mA < 200mA 13 Yes Yes DC Voltage
Comment
Low Supply, Full Brightness Nominal Supply, Low Brightness NMEA 2000 Spec. (1 LEN = 50mA) Indefinitely Energy Rated Per SAE J1113
Electrical Mechanical
Operating Voltage Power Consumption (Maximum) Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Parameter
Size
Value
6.875 x 5.75 x 1.75 (174.6mm x 146mm x 44.5mm)
Comment
Including Flanges for Mounting
Weight Mounting
Parameter
IEC 60945 Classification
Degree of Protection Operating Temperature Storage Temperature
Value
Exposed
IP67 -25C to 55C -40 to 70C
Environmental
Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
93%RH @ 40C per IEC 60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7 days @ 40C, 95%RH after 2 hour Salt Spray per IEC 60945-8.12 Conducted and Radiated Emission per IEC60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
15
ALM100
Alarm Module
Maretrons Alarm Module generates visual and audible alerts for any monitored condition. The Alarm Module includes an extremely loud 105 dB SPL Piezoelectric sounder, along with a red high-brightness LED to indicate an alarm condition. A second green LED incidates that the Alarm Module is powered and ready to be triggered. The audible alarm can sound any one of 32 distinct pre-programmed patterns to indicate different alerts. The Alarm Module can be triggered by alarms generated by Maretrons N2KView Vessel Monitoring System, or by Maretrons DSM250 Color Graphics Display. The Alarm Module mounts in a standard electric box or can be flush mounted on any surface. Completely waterproof, the Alarm Module can be mounted inside or outside the vessel.
NMEA 2000 Network Interface Super loud 105dB audible alarm Bright Red LED visual alarm Green LED status indicator Mounts in standard electrical wall box or flush mount directly in wall 32 selectable alarm patterns Waterproof - Can be mounted indoors or outdoors
Products
PART NUMBER ALM100-01 CP-BK-ALM100 CP-WH-ALM100 DESCRIPTION Alarm Buzzer with Black Cover Plate ALM100 Black Cover Plate ALM100 White Cover Plate
16
www.maretron.com 1-866-550-9100
Parameter
Value
105 dB SPL 2.9 kHZ
Comment
Mechanical Volume Control
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
Ce
4.50" (114mm)
Description
Periodic Data PGNs
PGN #
PGN Name
Default Rate
1 time/second N/A
N/A N/A
128720 Proprietary Alarm Status* 126464 PGN List (Transmit and Receive)
126996 Product Information 126998 Configuration Information
N/A
N/A
N/A N/A N/A N/A
2.75" (70mm)
128720 Configuration
*Future firmware updates will allow the ALM100 to be in conformance with the upcoming NMEA 2000 alarm messaging protocol, once it is defined.
Parameter
Value
9 to 32 Volts 100 mA 2 Yes Yes DC Voltage
Comment
NMEA 2000 Interface NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Electrical Mechanical
Parameter
Size
Value
13 oz. (368.5g)
Comment
2.75 x 4.50 x 2.00 (70mm x 114mm x 51mm) Including wall plate Mounts in standard single-gang electrical box
Weight
Parameter
IEC 60945 Classification
Degree of Protection
Value
Exposed
IP67 -25C to 55C -40C to 70C
Environmental
Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8? Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
17
Navigation Instruments
WSO100 SSC200 GPS200 DST100
Maretron brings you state-of-the-art, award-winning navigation instruments. Take our compass, for example. We were the first to bring solid-state compass technology to the marine industry, resulting in superior accuracy and incredible response time. The result rock solid radar overlay on your charting software and unprecedented autopilot performance. Our ultrasonic wind/weather station is another example of award-winning technology no moving parts and built from the ground up for the marine industry. Aerodynamically designed for accurate wind speed and direction even when the boat is heeled over in pitching and rolling seas. And of course, all our navigation instruments are engineered to the highest international marine standard (IEC 60945) for years of reliable service.
SAIL honors Freeman K. Pittmans memory with its annual FKP Awards, which recognize the finest and most innovative new products on the marketthe very stuff that Freeman sought out during his tenure at the magazine.
The NMMA Innovation Awards are presented each year at the Miami Boat Show and they recognize products that exhibit innovative distinction from other products, benefit to the marine industry and/or consumer, practicality, and cost-effectiveness.
18
The WSO100 provides these functions: Apparent Wind Speed Apparent Wind Direction Atmospheric Pressure Air Temperature Relative Humidity
Products
PART NUMBER WSO100-01 DESCRIPTION Ultrasonic Wind/Weather Station
20
www.maretron.com 1-866-550-9100
Parameter
Wind Speed Range Wind Speed Resolution Wind Speed Accuracy Wind Direction Accuracy Temperature Range Temperature Resolution Temperature Accuracy Relative Humidity Range
Value
0.5 to 99.5 knots (1 to 185 kph) 0.1 knot (0.19 kph) 5% or 1 knot (1.9 kph) 5 -25 to 55 C 0.1F (0.06C) 1.8F (1C) 0-99% RH
Comment
Specifications
88mm 3.45
Certifications
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
108mm 4.25
88.9mm 3.5
Description
PGN #
130306 130310 130311 Wind Data
PGN Name
Environmental Parameters Environmental Parameters PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Transport Protocol, Connection Management ISO Transport Protocol, Data Transfer ISO Address Claim ISO Address Command NMEA Complex Request/Command/Ack. Configuration
Default Rate
10 Times/Second 10 Times/Second 2 Times/Second N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Protocol PGNs
95.25mm 3.75
126720
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts <150mA 3 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
4.25 Dia. x 3.45 Tall (108mm Dia. x 88mm Tall) 10 oz. (283g) Pole
Value
Including Mounting Bracket Including Mounting Bracket Fits 1-14 TPI Standard Marine Mount
Comment
Parameter
IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
Environmental
21
SSC200
Maretrons SSC200 is a solid state, rate gyro electronic compass that provides better than 1 heading accuracy through 45 of roll and pitch angle, and better than 1 roll and pitch accuracy in static conditions. Each SSC200 is factory calibrated for maximum accuracy. It delivers precise, reliable heading information ten times per second, plus vessel attitude including pitch and roll readings once per second. A micromachined rate gyro is used by advanced stabilization algorithms to provide accurate, stable readings during dynamically changing conditions such as hard turns or rough seas, making it an ideal heading sensor for autopilot applications. Maretrons SSC200 is certified to the NMEA 2000 network standard and compatible with the NMEA 0183 digital interface standard. It connects directly with any NMEA 2000 network and/or NMEA 0183 listeners to share information with navigational software, chart plotters, autopilots, and dedicated instrument displays including Maretrons DSM250 graphical display.
The SSC200 can be automatically calibrated for deviation. Its dynamic accuracy is improved with advanced digital filtering of the 3-axis magnetometer, 2-axis accelerometer and rate gyro. The SSC200 is engineered and manufactured to the highest standards (IEC 60945 Maritime Navigation and Radio Communication Equipment). Its compact waterproof housing will provide years of reliable performance.
Products
PART NUMBER SSC200-01 DESCRIPTION Solid-State Rate/Gyro Compass
22
www.maretron.com 1-866-550-9100
Parameter
Static Heading Accuracy Heading Display Resolution
Settling Time
Value
<1 RMS 0.1
1 Second
Comment
45 Pitch and Roll - 15C to 35C With Maretron Display
To Static Accuracy after 35/Second Turn
Specifications
Heading Update Rate Heading Deviation Alignment Calibration Pitch and Roll Range Pitch and Roll Accuracy Pitch and Roll Display Resolution Pitch and Roll Update Rate Pitch and Roll to Boat Alignment Rate of Turn Range Rate of Turn Accuracy Rate of Turn Update Rate NMEA 0183 Standard
10 per Second Yes Yes 80 <1 0.1 1 per Second Yes 0 - 90/ Second 1 per Second 10 per Second Compatible Up to 38,400 Baud (40 Hz Update Rate) In Boat Calibration with Maretron Displays At 0 Pitch and Roll 0 Pitch and Roll - 15C to 35C Automatic In Boat Calibration with Maretron Displays With Maretron Display 45 Pitch and Roll - 15C to 35C With Maretron Display
Certifications
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Periodic Data PGNs
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
Description
127250
127257
PGN #
Vessel Heading
Attitude
PGN Name
10 Times/Second
1 Time/Second
Default Rate
Response to Requested PGNs 126464 126996 Protocol PGNs 126998 059392 059904 060416 060160 060928 065240 Maretron Proprietary PGNs 126208 126720
127251
Rate of Turn PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Transport Protocol, Connection Management ISO Transport Protocol, Data Transfer ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge Configuration
10 Times/Second N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
10 Times/Second N/A N/A 5 Times/Second 1 Time/Second N/A N/A N/A
Sentence
Transmitted Sentences Received Sentences
Heading, Deviation, and Variation Heading, Magnetic Heading, True Rate of Turn Maretron Proprietary Attitude (Pitch and Roll) Text Transmission Recommended Minimum Specific GNSS Data Course Over Ground and Ground Speed
Sentence Name
Description
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Size Weight Mounting
Parameter
Value
DC Voltage Average Current Drain NMEA 2000 Spec. (1 LEN = 50mA) Indefinitely Energy Rated Per SAE J1113
Including Mounting Flanges Including Mounting Bracket
Comment
Parameter
4.46 x 3.23 x 2.14 (113mm x 82mm x 54mm) 7 Oz. (198 g) Deck or Bulkhead
Value
Comment
IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Immunity Safety Precautions
Parameter
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Value
23
GPS200
Maretrons GPS200 is a state-of-the-art 32 channel GPS antenna and reciever capable of producing five position fixes per second. The GPS200 has unprecedented sensitivity and can even be mounted underneath a fiberglass deck. An additional benifit of the GPS200 is that it broadcasts precision magnetic variation information using the current position and world magnetic model (WMM-2010). The GPS200 antenna/receiver is a plug-and-play device that is fully compliant and certified to the NMEA 2000 Standard. It will directly connect to any NMEA 2000 network and communicate with navigational software, chart plotters, autopilots and dedicated instrument displays such as Maretrons DSM250 graphical display and its compact, waterproof housing provides years of reliable performance.
The GPS200 automatically decodes GPS correction signals from Satellite Based Augmentation Systems (SBAS) including the North American Wide Area Augmentation System (WAAS), the European Geostationary Navigation Overlay System (EGNOS), or the Asian Multifunctional Transport Satellite-based Augmentation System (MSAS) to provide better than 2.5m accuracy. The GPS200 is easily mounted to any 1 standard marine mount with its standard 1-14 male threads. It can also be mounted directly to a deck.
Products
PART NUMBER GPS200-01 DESCRIPTION GPS Antenna/Receiver
24
www.maretron.com 1-866-550-9100
Parameter
42mm 1.65 42mm 1.65 42mm 1.65
Position Accuracy (Autonomous) Position Accuracy (WAAS) Channels Tracking Sensitivity Position Update Rate Speed Update Rate Time Update Rate Hot Start Warm Start Cold Start
Value
<3m <2.5m 32 -159dBm 5 per Second 4 per Second 1 per Second 1 Seconds 33 Seconds 36 Seconds WAAS EGNOS MSAS <4g <1800m <515 m/sec 20 m/s3 Lithium (4-5) days
Comment
2D RMS (95% of Data Falls Within 10m) 2D RMS (95% of Data Falls Within 3m) Simultaneous Tracking of 32 Satellites 5 Hz Position Fix Calculation Rate
Specifications
Start Within Hours of Last Power Down Start Within Days of Last Power Down Start from Unknown Position North America Europe Asia
1 - 14 - UNS-2B Thread (1 - 14 TPI Standard Marine Mount) 1 - 14 - UNS-2B Thread (1 - 14 TPI Standard Marine Mount) 1 - 14 - UNS-2B Thread (1 - 14 TPI Standard Marine Mount)
Certifications
Battery Backup
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Standard
Comment
Description
Periodic Data PGNs
PGN #
Protocol PGNs
126992 128259 129025 129026 129029 129539 129540 127258 126464 126996 126998 129538 129541 059392 059904 060416 060160 060928 065240 126206
System Time Speed Position, Rapid Update COG and SOG, Rapid Update GNSS Position Data GNSS DOPs GNSS Satellites in View Magnetic Variation PGN List (Transmit and Receive) Product Information Configuration Information GNSS Control Status GPS Almanac Data ISO Acknowledge ISO Request ISO Transport Protocol, Connection Management ISO Transport Protocol, Data Transfer ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge
PGN Name
Default Rate
Mechanical Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Size Weight Mounting
Value
9 to 32 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Not Including Antenna Mount Base Not Including Antenna Mount Base
Parameter
4 dia. x 1.65Tall (102mm Dia. X 42mm Tall) 6 Oz. (170 g) Deck or Pole
Value
Comment
Parameter
IEC 60954 Classification Degree of Protection
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnet Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
25
DST100
Maretrons DST100 Smart Retractable Depth/ Speed/Temperature Transducer, delivers precise digital depth, accurate speed and exact water temperature even at speeds above 40 knots all with no programming or calibration necessary. Its patented Smart Sensor technology, retractable and removable sensor, and NMEA 2000 network connectivity make the DST100 easy to interpret, easy to install and connect with other navigation equipment, and easy to maintain. The DST100 measures precise water depth at 0.4m to 60m with a wide beam width and is tolerant to most deadrise angles. It reads water temperature from -10C to +40C at 1.0C accuracy, and accurate speed from 1 to 60 knots. At 235kHz it can be used with a fishfinder as an ideal navigation tool for sport or commercial fishing vesselsor with sailing vessels of all sizes.
The DST100s plastic, bronze, or stainless steel housing choices are compatible with any hull material. It includes a blank plug to replace its sensor unit when the vessel will be docked for extended periods or trailered. This prevents damage to the sensor and reduces fouling growth. Maretrons DST100 is CE compliant (IEC 60945) and is manufactured to the highest quality standards under ISO9K/2K procedures. Its compact, waterproof housing will provide years of reliable performance, making it the Smart choice in marine sensing.
Products
PART NUMBER DST100-01 M33-100 M33-495-01 33-398-04PW DESCRIPTION Depth/Speed/Temperature Triducer Bronze Housing Kit for DST100 Stainless Steel Housing Kit for DST100 Spare Paddle Wheel Kit
26
www.maretron.com 1-866-550-9100
Parameter
Depth Operating Frequency Beam Width Minimum Depth
Value
235 kHz 10 x 44 0.4 meters 60 meters Up to 40 knots 1 second Paddlewheel 1 52 knots 1 second -10C to 40C 1.0C 0.01C 22
Comment
Wide Beam Angle Deadrise Angle Tolerant No Calibration Required
High Speed Bottom Tracking Capability
Specifications
Maximum Depth Depth Tracking Speeds Depth Update Rate Speed Sensor Speed Range Speed Update Rate Water Temperature Range Water Temperature Accuracy Water Temperature Resolution Deadrise Angle
No Calibration Required
Microprocessor Signal Processing Accuracy
Plastic
Certifications
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B+ IEC 61162-3 IEC 60945 Electromagnetic Compatibility
Description
PGN#
128267 Water Depth
128259
PGN Name
Speed (Water Referenced)
Default Rate
1 Time/Second
1 Time/Second
Environmental Parameters (Water Temperature) 2 Times/Second Distance Log PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge 1 Time/Second N/A N/A N/A N/A N/A N/A N/A N/A
Protocol PGNs
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection
Value
9 to 16 Volts <50mA 1 Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely
Environmental Mechanical
Parameter
Size Weight Mounting Hole Diameter for Mounting
Value
2.94 Dia. X 4.87 Tall (74.7mm Dia. X 123.7mm Tall) 12 Oz. (340 g) Lexan/Bronze/Stainless Steel 2 (51 mm)
Comment
Including Mounting Flanges Bronze/Stainless Steel Optional
Parameter
IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature
Value
Submerged IP68 -10C to 40C -40C to 71C
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
27
Maretron brings you plug-and-play engine and vessel monitoring electronics for distributing critical data throughout the vessel. Whether youre down in the engine room or up at the fly bridge, all the information you need is available everywhere you need it. Gone are the days of disparate systems that fail to communicate with each other. With Maretrons networked electronic components like engine and tank monitors, vessel data is combined for advanced features like fuel economy (MPG or GPM) or distance and time to empty (calculated from engine fuel rate, vessel speed from GPS, and fuel remaining from tank monitor). Finally, true vessel monitoring on a single network combining information for display anywhere and everywhere you need it.
J2K100
RAA100
SIM100
TLM100
EMS100
ACM100
RIM100
TLM150
28
TLA100
DCM100
Temperature Module
TMP100
TLM200
J2K100
Maretrons J2K100 attaches directly into J1939 networks of compatible engines, transmissions, and gensets and converts the J1939 data to the new marine digital interface (NMEA 2000). Critical engine, transmission, and genset data is then distributed throughout the vessel over a single cable where it can be monitored by any NMEA 2000 compatible display. The J2K100 can also be used as part of a complete fuel computer. Simply connect the J2K100 together with Maretron universal displays (DSM250/N2KView) and GPS antenna/receiver (GPS100) and you have a system capable of displaying gallons per hour and/or miles per gallon.
The J2K100 converts the following information: AC Generator Current AC Generator Frequency AC Generator Voltage Tachometer Engine Hours Coolant Pressure Coolant Water Temperature Engine Oil Pressure Engine Oil Temperature Boost Pressure Fuel Rate Monitoring Charging Voltage Percent Engine Load Percent Engine Torque Rated Engine Speed VIN Software ID Transmission Gear Transmission Oil Pressure Transmission Oil Temperature
The J2K100 is compatible with any engine, transmission, or genset equipped with a J1939 interface, including products from the following manufacturers: Caterpillar Cummins Detroit Diesel John Deere Kohler Northern Lights Onan Perkins Steyr Volvo Penta Yanmar
Products
M PART NUMBER J2K100-01 MCF-2M-D4 MCF-2M-D12 MCF-2M-D12CAT DESCRIPTION
J1939 to NMEA 2000 Gateway J2K100 adapter Micro female to Deutsche 4 Pin 2 Meter Cordset J2K100 adapter Micro female to Deutsche 12 Pin 2 Meter Cordset J2K100 adapter Micro female to Deutsche 12 Pin 2 T cable
30
www.maretron.com 1-866-550-9100
J1939 SPN/PGN
190 / 61444 102 / 65270 100 / 65263 175 / 65262 110 / 65262 167 / 65271 183 / 65266 247 / 65253 109 / 65263 94 / 65263 92 / 61443 513 / 61444 189 / 65214 237 / 65260 234 / 65242 523 / 61445 127 / 65272 177 / 65272
35mm 1.38
62.23mm 2.45
62.23mm 2.45
Certifications
76.2mm 3.0
76.2mm 3.0
88mm 3.46
Engine Speed Engine Turbocharger Boost Pressure Engine Oil Pressure Engine Oil Temperature 1 Engine Coolant Temperature Alternator Potential (Voltage) Engine Fuel Rate Engine Total Hours of Operation Engine Coolant Pressure Engine Fuel Delivery Pressure Engine Percent Load at Current Speed Actual Engine Percent Torque Engine Rated Speed Vehicle Identification Number Software Identification Transmission Current Gear Transmission Oil Pressure Transmission Oil Temperature
Description
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
88mm 3.46
Standard
Comment
79mm 3.11
Description
PGN #
127488 127489 127498 127493 65030 65226 65227 65228 65229 65230 65231 65232 65234 65235 65236 126464 126996 126998 059392 059904 060928
79mm 3.11
62.23mm 2.45
35mm 1.38
79mm 3.11
Protocol PGNs
Engine Parameters, Rapid Update Engine Parameters, Dynamic Engine Parameters, Static Transmission Parameters, Dynamic J1939 Generator Average Basic AC Quantities J1939 Diagnostic Message #1 J1939 Diagnostic Message #2 J1939 Diagnostic Message #3 88mm J1939 Diagnostic Message #4 3.46 J1939 Diagnostic Message #5 J1939 Diagnostic Message #6 J1939 Diagnostic Message #8 J1939 Diagnostic Message #10 J1939 Diagnostic Message #11 J1939 Diagnostic Message #12 PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim
35mm 1.38
PGN Name
Default Rate
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Size Weight
Parameter
Value
DC Voltage Average Current Drain NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Including Flanges For Mounting
Comment
Parameter
Value
Comment
IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Parameter
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Value
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
31
EMS100
Maretrons EMS100 plugs directly into engine wiring harnesses and converts analog signals such as water temperature and oil pressure to the new marine digital interface (NMEA 2000). Critical engine data is then distributed throughout the vessel over a single cable where it can be monitored by any NMEA 2000 compatible display. The EMS100 is compatible with existing instrument panels and key switches so you dont need to remove them while upgrading to newer digital technology. For new installations, the EMS100 and a compatible NMEA 2000 display can replace the traditional analog instrument panel.
The EMS100 provides these functions: Tachometer Engine Hours Coolant Water Temperature Engine Oil Pressure Boost Pressure Charging Voltage Drive Trim Fuel Filter Alarm Boost Alarm Coolant Water Level Alarm Engine Oil Pressure Alarm Exhaust (Salt Water Flow) Alarm Coolant Water Temperature Alarm
Products
PART NUMBER EMS100-01 EMSYMR01 DESCRIPTION Analog Engine Monitoring System Yanmar Harness
32
www.maretron.com 1-866-550-9100
Parameter
Tachometer Engine Hours Oil Pressure Coolant Water Temp
Type
Analog/Digital Input Logged with Key On Analog Input Analog Input Analog Input Analog Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input Alarm/Switch Input
Comment
Configurable by # of Teeth Stored Indefinitely in Non-Volatile Memory Sensor Voltage Monitor/Sensitize Sensor Voltage Monitor/Sensitize Sensor Voltage Monitor/Sensitize Sensor Voltage Monitor/Sensitize
Specifications Certifications
Boost Pressure Drive Trim Angle Charging Voltage Lube Oil Filter Alarm Boost Pressure Alarm Coolant Water Temperature Alarm Oil Pressure Alarm Exhaust (Salt Water Flow) Alarm Clutch Oil Pressure Alarm Diesel Preheat Alarm Diesel Preheat Alarm
127mm 5
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
32mm 1.25
Description
Periodic Data PGNs
PGN #
127488 127489 126464 126996 126998 059392 059904 060416 060160 060928 065240 126208 126720
114mm 4.5
Protocol PGNs
Engine Parameters, Rapid Update Engine Parameters, Dynamic PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Transport Protocol, Connection Management ISO Transport Protocol, Data Transfer ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge Configuration
PGN Name
Default Rate
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts 9 to 32 Volts <150mA 1 Yes Yes
Comment
NMEA Interface Engine Interface From Battery NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
Size Weight
Value
5 x 4.5 x 1.25 (127mm x 114mm x 32mm) 12 Oz. (340 g)
Comment
Excluding Wiring Harness Excluding Wiring Harness
Parameter
IEC 60945 Classification Degree of Protection
Value
Exposed IP68 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
33
TLA100
The TLA100 is used to adapt commercially available resistive tank senders to the NMEA 2000 network. This allows you to observe tank levels anywhere on the vessel where there are NMEA 2000 compatible displays such as the Maretron DSM250. The TLA100 is compatible with both the American standard (240-30 ohm) and the European standard (10-180 ohm) resistive senders. In fact, the TLA100 can be calibrated for any resistance between 0 and 300 ohms. Unlike most tank senders that only work with rectangular tanks, the TLA100 can be calibrated for irregular tank shapes so you know the true level of the tanks. You can also use the TLA100 with analog gauges at the same time as NMEA 2000 so you dont have to give up existing analog gauges to enjoy the advantages of digitally networked information.
The Maretron TLA100 has the following features: NMEA 2000 Interface Adapts American standard (240-30 ohm) resistive senders to NMEA 2000 Network Adapts European standard (10-180 ohm) resistive senders to NMEA 2000 Network Calibrated for any Resistance Range from 0 to 300 Ohms or 300 to 0 Ohms Accommodates Irregularly Shaped Tanks with 16 Point Calibration 16 Programmable Tank Types Including Fuel, Fresh Water, Waste Water, Live Well Programmable Tank Number(s) Up to 16 per Tank Type Programmable Tank Capacity Works Alongside of Analog Gauges Can be Used Standalone without Analog Gauges
Products
PART NUMBER TLA100-01 DESCRIPTION Tank Level Adapter
34
www.maretron.com 1-866-550-9100
Parameter
Accuracy
Value
+/-2% +/-1% 16 16 240-30 ohms 10-180 ohms 0-300 ohms Yes Yes Yes
Comment
Does Not Include Inaccuracies of Analog Gauge or Sender Worst Case (Resolution Better at High Resistance Values) Fuel, Fresh Water, Waste Water, Live Well, Oil, etc. 16 Tanks per Tank Type Numbered 0-15 Standard Sender Types are User Selectable Standard Sender Types are User Selectable Non-Standard Sender Calibration Can be Calibrated for any Shape Tank Allows Displays to Calculate Amount Remaining Can be Used With or Without Analog Gauges
Resolution Number of Tank Types Number of Tanks per Tank Type American Standard Senders European Standard Senders Calibration Resistance Range Support for Irregularly Shaped Tanks Programmable Tank Capacity Analog Gauge Support
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B+ IEC 61162-3 IEC 60945 Electromagnetic Compatibility
25mm 1.0
99mm 3.9
30mm 1.2
Description
Periodic Data PGNs
PGN #
127505 126464 126996 126998 Fluid Level
PGN Name
PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge
Default Rate
0.4 Times/Second N/A N/A N/A N/A N/A N/A N/A N/A
25mm 1.0
30mm 1.2
Protocol PGNs
Parameter
Value
9 to 16 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50mA) Indefinitely Energy Rated per SAE J1113
Electrical Mechanical
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Parameter
Size
Value
3.9 x 1.2 x 1.0 (99mm x 30mm x 25mm)
Comment
Excluding NMEA 2000 Connector & Cable
Weight Mounting
Parameter
IEC 60945 Classification Degree of Protection Operating Temperature
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
35
RAA100
Maretrons RAA100 is used to adapt commercially available resistive rudder senders to the NMEA 2000 network. This allows you to observe rudder angle anywhere on the vessel where there are NMEA 2000 compatible displays such as the Maretron DSM250. The RAA100 is compatible with both the American standard (240-30 ohms) and European standard (10-180 ohm) resistive senders. In fact, the RAA100 can be calibrated for any resistance between 0 and 300 ohms. You can also use the RAA100 with analog gauges at the same time as NMEA 2000 so you dont have to give up existing analog gauges to enjoy the advantages of digitally networked information.
The Maretron RAA100 has the following features: NMEA 2000 Interface Adapts American standard (240-30 ohm) resistive senders to NMEA 2000 Network Adapts European standard (10-180 ohm) resistive senders to NMEA 2000 Network Can be Calibrated for any Resistive Sender Ranging from 0-300 Ohms or 300-0 Ohms Three Point Electronic Calibration eliminates need for Mechanical Adjustment or Calibration Can be Used Standalone Without Analog Gauges
Products
PART NUMBER RAA100-01 DESCRIPTION Rudder Angle Adapter
36
www.maretron.com 1-866-550-9100
Parameter
Value
+/-2% +/-1% 240-30 ohms 10-180 ohms 0-300 ohms Yes Yes
Comment
Does Not Include Inaccuracies of Analog Gauge or Sender Worst Case (Resolution Better at High Resistance Values) Standard Sender Types are User Selectable Standard Sender Types are User Selectable Non-Standard Sender Calibration Eliminates need to mechanically adjust or calibrate Can be Used With or Without Analog Gauges
Specifications Certifications
Accuracy Resolution American Standard Senders European Standard Senders Calibration Resistance Range Electronic Calibration Analog Gauge Support
Top View
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B+ IEC 61162-3 IEC 60945 Electromagnetic Compatibility
End View
25mm 1.0
99mm 3.9
30mm 1.2
Description
Periodic Data PGNs
PGN #
127254 126464 126996 126998 Rudder
PGN Name
PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge Configuration
Default Rate
10 Times/Second N/A N/A N/A N/A N/A N/A N/A N/A N/A
Side View
End View
25mm 1.0
Protocol PGNs
99mm 3.9
30mm 1.2
126720
Parameter
Value
9 to 16 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50mA) Indefinitely Energy Rated per SAE J1113
Electrical Mechanical
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Parameter
Size
Value
3.9 x 1.2 x 1.0 (99mm x 30mm x 25mm)
9 oz. (255g) Any Orientation
Comment
Excluding NMEA 2000 Connector & Cable
Weight Mounting
Parameter
IEC 60945 Classification Degree of Protection Operating Temperature
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
37
ACM100
Maretrons ACM100 is a device which monitors AC power sources and outputs information about these sources onto the industry standard NMEA 2000 marine data network. ACM100 output information is then displayed with networked NMEA 2000 equipment such as the Maretron DSM250 dedicated display or with NMEA 2000 compatible software such as Maretron N2KView.
Products
PART NUMBER ACM100-01 M000630 DESCRIPTION Alternating Current (AC) Monitor ACM100 Current Transducer
NMEA 2000 Interface Waterproof Connectors Sealed Waterproof Enclosure Opto-Isolated from NMEA 2000 Eliminating Potential Ground Loops Monitoring of busses carrying AC power and transmitting: - Voltage - Frequency Monitoring AC Power Sources such as Utilities and Generators and transmitting: - Voltage - Current - Frequency - Real Power - Reactive Power - Apparent Power - Power Factor - Total Energy Imported - Total Energy Exported
38
www.maretron.com 1-866-550-9100
Measurement Voltage Range Measurement Voltage Accuracy Measurement Current Range Measurement Current Accuracy
Parameter
0 to 240VAC 1% 0 to 200A 1%
Value
AC Voltage 0 to 240 VAC With included current transformer With included current transformer
Comment
51.6mm 2.03
38.1mm 1.5
87.63mm 3.45
Certific
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Standard
Comment
Description
PGN #
65001 65002 65003 65004 65005 65006 65007 65008 65009 65010
87.63mm 3.45
76.2mm 3.0
76.2mm 3.0
88.9mm 3.50
88.9mm 3.50
106.7mm 4.20
106.7mm 4.20
51.6mm 2.03
106.7mm 4.20
51.6mm 2.03
38.1mm 1.5
Protocol PGNs
65011 65012 65013 65014 65015 65016 65017 65018 65019 65020 88.9mm 3.50 65021 65022 65023 65024 65025 65026 65027 65028 65029 65030 126464 126996 126998 38.1mm 1.5 059392 059904 060928 065240 126208 128720
Bus #1 Phase C Basic AC Quantities Bus #1 Phase B Basic AC Quantities Bus #1 Phase A Basic AC Quantities Bus #1 Average Basic AC Quantities Utility Total AC Energy Utility Phase C AC Reactive Power Utility Phase C AC Power Utility Phase C AC Basic Quantities Utility Phase B AC Reactive Power Utility Phase B AC Power
PGN Name
Utility Phase B AC Basic Quantities Utility Phase A AC Reactive Power Utility Phase A AC Power Utility Phase A AC Basic Quantities Utility Total AC Reactive Power Utility Total AC Power Utility Average Basic AC Quantities Generator Total AC Energy Generator Phase C AC Reactive Power Generator Phase C AC Power Generator Phase C AC Basic Quantities Generator Phase B AC Reactive Power Generator Phase B AC Power Generator Phase B AC Basic Quantities Generator Phase A AC Reactive Power Generator Phase A AC Power Generator Phase A AC Basic Quantities Generator Total AC Reactive Power Generator Total AC Power Generator Average Basic AC Quantities PGN List (Transmit and Receive) Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Configuration
9 to 32 Volts 100 mA 2 Yes Yes
10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second N/A N/A N/A N/A N/A N/A N/A N/A N/A
10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second 10 times/second
Default Rate
N2KView Screen
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Size Weight
Parameter
Value
DC Voltage NMEA 2000v Interface NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Excluding NMEA 2000 Connector & Cable
Comment
Parameter
Value
Comment
IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature Relative Humidity Vibration Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Parameter
Exposed IP64 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Value
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
39
DCM100
Maretrons DCM100 Monitor is an advanced electronic monitoring device used to measure the voltage and current of any direct current (DC) power source or load. Examples of DC power sources that can be monitored with the DCM100 include batteries, alternators, solar panels, and wind generators. The DCM100 can also be used to monitor DC loads like inverters, windlasses, DC refrigerators, or any DC branch circuit. When the DCM100 is used to monitor batteries, sophisticated circuitry and software algorithms monitor battery temperature, load current, charging current and terminal voltage to precisely compute battery state of charge, state of health, and time remaining. To measure current, the DCM100 uses an included state-of-the-art Hall effect current sensor which simply slips over the wire you dont have to break connections or install connectors as you do with inline shunts used by other solutions. Best of all, the DCM100 is NMEA 2000 certified so you can view any and all DC information anywhere on the vessel using a compatible NMEA 2000 display. The DCM100 is a key component of Maretrons N2KView vessel monitoring and control system. Battery Voltage Battery Current Ripple Voltage Battery Case Temperature State of Charge Time Remaining Charge Efficiency Factor
Products
PART NUMBER DCM100-01 FC01 LEMHTA200-S LEMHTA400-S LEMHTA600-S TR3K DESCRIPTION Direct Current (DC) Monitor DCM100 Battery Harness with Fuse 200 Amp Current Transducer with Cable 400 Amp Current Transducer with Cable 600 Amp Current Transducer with Cable DCM100 Ring/Under Bolt Temperature Probe
40
www.maretron.com 1-866-550-9100
Certifications Specifications
51.6mm 2.03
Parameter
Battery Sense Voltage Range Battery Sense Voltage Accuracy Battery Current Range Battery Current Accuracy
Value
0 to 50 VDC 100 mV 0 to 200A 1%
Comment
38.1mm 1.5
With included Hall-effect current sensor With included Hall-effect current sensor
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
87.63mm 3.45
87.63mm 3.45
Description
Periodic Data PGNs
88.9mm 3.50
PGN#
127506
127508
PGN Name
DC Detailed Status
Battery Status
Default Rate
0.67 times/second
0.67 times/second
76.2mm 3.0
88.9mm 3.50
76.2mm 3.0
127513
126464 126996
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
106.7mm 4.20
126998
059392 059904
Configuration Information
ISO Acknowledge ISO Request
106.7mm 4.20
Protocol PGNs
87.63mm 3.45
Parameter
Value
9 to 16 Volts 9 to 32 Volts NMEA Interface
Comment
Battery Interface VPWR+, VPWR- NMEA 2000 Interface NMEA 2000 Spec. (1 LEN = 50mA) Indefinitely Energy Rated Per SAE J1113
Electrical
51.6mm 2.03
38.1mm 1.5
Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Mechanical
Parameter
Size Weight
51.6mm 2.03
Value
3.50 x 4.20 x 2.03 (88.9mm x 106.7mm x 51.6mm) 13 oz. (368.5 g)
Comment
Including Flanges for Mounting
Parameter
IEC 60945 Classification Degree of Protection
38.1mm 1.5
Value
Exposed IP64 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8? Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
41
SIM100
Maretrons Switch Indicator Module monitors switch closure devices including, but not limited to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), and vessel monitoring equipment (e.g., valve closed/open, high water bilge). The SIM100 continually monitors these switch closure devices and broadcasts information over the NMEA 2000 network about the switch state so the crew can be alerted to potential conditions or problems that warrant further investigation. Advanced features of the SIM100 include the ability to detect whether or not power has been disconnected from the monitored device or if the signal wires have been disconnected due to either corrosion, tampering, or for any other reason (if the monitored device is so equiped). With the SIM100, you can rest assured that critical sensors are receiving power, signal wires are connected, and all the safety, security and vessel functions are under constant supervision.
Monitors and reports switch status Can detect and report problems like opens and shorts in switch circuits Compatible with Maretron Supplied - Heat Detectors - Smoke Detectors - Carbon Monoxide Detectors - Bilge Water Detectors Also Compatible With - Magnetic Switches - Glass Break Detectors - Door, Hatch, and Porthole Magnetic Switches
Products
PART NUMBER SIM100-01 SH-449CSTE CO1000-S-W LP1000-S-W BHW100 MD-6157-N MS-1035 MS-1085-N MS-1055-N MS-1075 DESCRIPTION Switch Indicator Module Smoke/Heat Detector Carbon Monoxide (CO) Detector (Surface Mount White) Liquid Petroleum (LP) Detector (Surface Mount White) Bilge High Water Detector Motion Detector Magnetic Switch Rectangular (Indoor) Magnetic Switch Rectangular (Outdoor) Magnetic Switch Cylinder (Indoor/Outdoor) Magnetic Switch Recessed (Indoor/Outdoor)
42
www.maretron.com 1-866-550-9100
Parameter
End of Line Resistor
Value
8 K 5%
Comment
Included with Maretron-supplied sensors
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
51.6mm 2.03
38.1mm 1.5
Cert
Description
Periodic Data PGNs
Response to Requested PGNs
PGN #
127501
126464
PGN Name
Binary Switch Bank Status
PGN List (Transmit and Receive)
Default Rate
1 time/15 seconds and on switch change N/A N/A N/A N/A N/A N/A N/A N/A N/A
87.63mm 3.45
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge Configuration
87.63mm 3.45
059904
060928 065240
88.9mm 3.50
76.2mm 3.0
88.9mm 3.50
Protocol PGNs
76.2mm 3.0
126208
Electrical
106.7mm 4.20
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
106.7mm 4.20
Parameter
Value
9 to 32 Volts 100 mA 2 Yes Yes DC Voltage
Comment
NMEA 2000 Interface NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
Size Weight
38.1mm 1.5
Value
3.50 x 4.20 x 2.03 (88.9mm x 106.7mm x 51.6mm) 13 oz. (368.5 g)
Comment
Including Flanges for Mounting
51.6mm 2.03
51.6mm 2.03
38.1mm 1.5
Parameter
IEC 60945 Classification 87.63mm Degree of Protection
3.45
Value
Exposed IP64 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission 106.7mm Electromagnetic Immunity Safety Precautions
4.20 88.9mm 3.50
76.2mm 3.0
51.6mm 2.03
38.1mm 1.5
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
43
RIM100
Maretrons Run Indicator Module monitors both AC and DC electrical circuits and reports, over an NMEA 2000 network, whether or not the electrical circuit is energized and running. The RIM100 works equally as well for monitoring manually switched loads (e.g., running lights, anchor lights, or deck lights) as it does for automatically switched loads. Monitoring automatically switched loads (e.g., bilge pumps, engine exhaust/intake fans, and transfer pumps) via the RIM100 is especially useful because you know exactly when equipment is, or isnt running. Monitors and reports the running status of connected devices Works with both AC and DC loads Works with both automatically and manually switched loads Can indicate the status of a wide variety of loads - Bilge Pumps - Winches - Running Lights - Transfer Pumps - Exhaust/Intake Fans
Products
PART NUMBER RIM100-01 DESCRIPTION Run Indicator Module
44
www.maretron.com 1-866-550-9100
Parameter
ON Voltage Range (DC)
Value
9VDC to 240VDC
Comment
RMS
9VAC to 240VAC
51.6mm 2.03
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
38.1mm 1.5
Cert
Description
Periodic Data PGNs
Response to Requested PGNs
87.63mm 3.45
PGN #
127501
126464
PGN Name
Binary Switch Bank Status
PGN List (Transmit and Receive)
Default Rate
1 time/15 seconds and on switch change N/A N/A N/A N/A N/A N/A N/A N/A N/A
87.63mm 3.45
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA Request/Command/Acknowledge Configuration
76.2mm 3.0
88.9mm 3.50
059904
Protocol PGNs
88.9mm 3.50
060928 065240
76.2mm 3.0
126208
106.7mm 4.20
Electrical
Parameter
Value
9 to 32 Volts 100 mA 2 Yes Yes DC Voltage
Comment
NMEA 2000 Interface NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Mechanical
51.6mm 2.03
Parameter
Size Weight
38.1mm 1.5
Value
13 oz. (368.5 g)
Comment
Including Flanges for Mounting
51.6mm 2.03
38.1mm 1.5
87.63mm
Parameter
Value
Exposed IP64 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Degree of Protection
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
106.7mm 4.20 88.9mm 3.50
76.2mm 3.0
51.6mm 2.03
38.1mm 1.5
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
45
TMP100
Temperature Module
Maretrons TMP100 measures the temperature for up to 6 temperature probes and reports the information over an NMEA 2000 network. The TMP100 supports up to 4 thermistor probes and 2 high temperature thermocouple probes. Optional thermistor probes (-20C to 80C or -4F to 176F) cover a wide range of applications including cabin air temperature, engine room air temperture, refrigerator/ freezer temperature, under bolt temperature (inverters, charges, pumps, motors, etc.), tank temperatures (live well bait, hot water, etc.), and air duct temperatures. The optional thermocouple probes (0C to 900C or 32 to 1652F) are used to measure Exhaust Gas Temperature (EGT) as part of a comprehensive fuel management system.
Six External Temperature Probes are Measured and Broadcast Over NMEA 2000 Network Four Channels for Thermistor Probes and 2 Channels for High Temperature Thermocouple Probes Wide Variety of Applications Supported with Optional Temperature Probes - Cabin Temperature - Engine Room Temperature - Under Bolt Temperature (Inverters, Chargers, Pumps, etc.) - Refrigerator/Freezor Temperature - Tank Temperatures (Live Well Bait, Hot Water, etc.) - Air Duct Temperature
Products
PART NUMBER TMP100-01 TR3K TP-AAP-1 TP-IP-1 TP-EGT-1 DESCRIPTION Temperature Module TMP100 Ring/Under Bolt Temperature Probe TMP100 Ambient Air Temperature Probe TMP100 Immersion (Tanks, Plenums, etc.) Temperature Probe TMP100 Exhaust Gas Temperature (EGT) Probe
- Exhaust Gas Temperature Optional Temperature Probes - Ambient Air Temperature Probe (-20C to 80C or -4F to 176F) - Ring Terminal Probe (-20C to 80C or -4F to 176F) - Immersion Probe for Tanks or Plenums (-20C to 80C or -4F to 176F) - Exhuast Gas Temperature Probe (0C to 900C or 32 to 1652F)
46
www.maretron.com 1-866-550-9100
ns
Parameter
Measurement Range Thermistor Measurement Accuracy Thermistor Measurement Range Thermocouple Measurement Accuracy Thermocouple
Value
-20C to 80C (-4F to 176F) 2C ( 3.6F) +0C to 700C (32F to 1292F) 2C ( 3.6F)
Comment
With supplied thermistor probe With supplied thermistor probe With supplied thermocouple probe With supplied thermocouple probe
38.1mm 1.5
Spe
51.6mm 2.03
cific
atio
Standard
NMEA 2000 Standard Maritime Navigation and Radio Communication Equipment & Systems Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level A IEC 61162-3 IEC 60945 Electromagnetic Compatibility
87.63mm 3.45
Description
PGN #
PGN Name
Temperature Sources: Sea Temperature Outside Temperature Inside Temperature Engine Room Temperature Main Cabin Temperature Live Well Temperature Bait Well Temperature Refrigeration Temperature Heating System Temperature Freezer Temperature
PGN List (Transmit and Receive)
Default Rate
87.63mm 3.45
76.2mm 3.0
88.9mm 3.50
127501
0.5 times/second
76.2mm 3.0
88.9mm 3.50
106.7mm 4.20
106.7mm 4.20
126464
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA
88.9mm Configuration 3.50 Exhaust Gas Temperature
059904
Protocol PGNs
87.63mm 3.45
060928 065240
126208
51.6mm 2.03 3.0 Maretron Proprietary PGNs 128720 38.1mm 1.5 76.2mm
51.6mm 2.03
Electrical
Parameter
Operating Voltage Power Consumption
106.7mm 4.20
Value
9 to 32 Volts 100 mA 2 Yes Yes DC Voltage
Comment
NMEA 2000 Interface NMEA 2000 Spec. (1LEN = 50 mA) Indefinitely Energy Rated per SAE J1113
38.1mm 1.5
Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Mechanical
Parameter
Size
51.6mm Weight 2.03 38.1mm 1.5
Value
3.50 x 4.20 x 2.03 (88.9mm x 106.7mm x 51.6mm) 13 oz. (368.5 g)
Comment
Including Flanges for Mounting
Parameter
IEC 60945 Classification Degree of Protection
Value
Exposed IP64 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
Operating Temperature Storage Temperature Relative Humidity Vibration Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
47
TLM100
Maretrons TLM100 is used to sense fluid levels of tanks by using ultrasonic technology. Ultrasonic, or sound waves, are transmitted via the TLM100 mounted at the top of the tank and the flight times of the sound waves to and from the fluid are measured much like a depth sensor. What this means for you is that there are no difficult to handle long probes protruding into the tank, which often foul and/ or corrode. Once the TLM100 calculates and transmits the fluid level over the NMEA 2000 network, you can observe tank levels anywhere on the vessel where there is an NMEA 2000 compatible display such as the Maretron DSM250. The TLM100 is capable of sensing fluid levels in tanks up to 40 (1.02m) in depth. It can be used for diesel, fresh water, waste water, black water, and oil tanks (see TLM150 for gasoline tanks or TLM200 for deeper tanks). Unlike most tank senders that only work with rectangular tanks, the TLM100 can be calibrated for irregular tank shapes so you can know the true fluid level in your tanks. The TLM100 is mounted directly to the top of tanks using the industry standard SAE J1810 5-hole mounting pattern.
The TLM100 can also be mounted to tanks with threaded tank openings using optional adapters that included both a 1.5 NPT and a 1.25 BSP adapter. There are other important TLM100 optional accessories including an airlock for black water applications, which keeps the face of the ultrasonic transmitter from fouling and an optional focus tube to permit use on boats with planing hulls, which is required if the vessel spends a significant amount of time with the bow pitched up. Most importantly, the TLM100 is NMEA 2000 certified so you can view any and all tank levels anywhere on the vessel when using a compatible NMEA 2000 display. The TLM100 is another key component of Maretrons N2KView vessel monitoring and control system.
Products
PART NUMBER TLM100-01 TA-5H-1.25BSP TA-5H-1.5NPT TAL-5H TAL-1.25BSP TAL-1.5NPT TFT-5H TFT-1.25BSP TFT-1.5NPT DESCRIPTION Tank Level Monitor (40 Depth Tanks) 1.25 BSP Displacement Hull Tank Adapter 1.5 NPT Displacement Hull Tank Adapter SAE 5-Bolt Pattern Black Water Airlock 1.25 BSP Black Water Airlock 1.5 NPT Black Water Airlock SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube 1.25 BSP Non-Displacement Hull Focus Tube 1.5 NPT Non-Displacement Hull Focus Tube
48
www.maretron.com 1-866-550-9100
Specifications
Parameter
Accuracy Resolution Number of Tank Types Number of Tanks per Tank Type Maximum Tank Depth Minimum Depth Reading Support for Irregularly Shaped Tanks Programmable Tank Capacity Maximum Tank Angle
Value
+/-2% +/-1% 16 16 40 (1.02m) 2 (5.08cm) Yes Yes 6 15
Sensor Deadband
Comment
Fuel, Fresh Water, Waste Water, Live well, Oil, etc. 16 Tanks per Tank Type Numbered 0-15
Can be Calibrated for any Shape Tank Allows Displays to Calculate Amount Remaining Without focus tube With focus tube
Standard
NMEA 2000 Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B Tested to IEC 60945 Electromagnetic Compatibility
Description
Periodic Data PGNs
Response to Requested PGNs
PGN #
127505
126464
PGN Name
Fluid Level
PGN List (Transmit and Receive)
Default Rate
0.4 times/second N/A N/A N/A N/A N/A N/A N/A N/A
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA
059904
Protocol PGNs 060928 065240
126208
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
Size Weight Mounting
Value
3.9 x 1.2 x 1.0 (99mm x 30.5mm x 25.4mm) 2.7 dia. X 0.9 (68.6mm dia. x 22.9mm) 8.5 (215.9mm) 12 oz. (340g) SAE J1810 5-hole bolt pattern
Comment
Interface Component Sensor Component Interconnecting Cable Can mount to 1.25 BSP or 1.5 NPT using available adapters
Parameter
IEC 60945 Classification Degree of Protection
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
DSM250 Screen Shots
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
49
TLM150
Maretrons TLM150 is used to sense gasoline fluid levels of tanks using ultrasonic technology. Ultrasonic, or sound waves, are transmitted via the TLM150 mounted at the top of the tank and the flight times of the sound waves to and from the fluid are measured much like a depth sensor. What this means for you is that there are no difficult to handle long probes protruding into the tank, which often foul and/or corrode. Once the TLM150 calculates and broadcast the fluid level over the NMEA 2000 network, you can observe tank levels anywhere on the vessel where there is an NMEA 2000 compatible display such as the Maretron DSM250. The TLM150 is capable of sensing gasoline levels in tanks up to 24 (0.61m) in depth (see TLM100 for fluid types other than gasoline in tanks up to 40 or the TLM200 for tanks up to 104). Unlike most tank senders that only work with rectangular tanks, the TLM150 can be calibrated for irregular tank shapes so you can know the true fluid level in your tanks.
The TLM150 is mounted directly to the top of tanks using the industry standard SAE J1810 5-hole mounting pattern. The TLM150 can also be mounted to tanks with threaded tank openings using optional adapters that include both a 1.5 NPT and a 1.25 BSP adapter. The other important optional accessory for the TLM150 is the focus tube to permit use on boats with planing hulls, which is required if the vessel spends a significant amount of time with the bow pitched up. Most importantly, the TLM150 is NMEA 2000 certified so you can view any and all tank levels anywhere on the vessel when using a compatible NMEA 2000 display. The TLM100 is another key component of Maretrons N2KView vessel monitoring and control system.
Products
PART NUMBER TLM150-01 TA-5H-1.25BSP TA-5H-1.5NPT TFT-5H TFT-1.25BSP TFT-1.5NPT DESCRIPTION Tank Level Monitor (24 Depth Gasoline Tanks) 1.25 BSP Displacement Hull Tank Adapter 1.5 NPT Displacement Hull Tank Adapter SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube 1.25 BSP Non-Displacement Hull Focus Tube 1.5 NPT Non-Displacement Hull Focus Tube
50
www.maretron.com 1-866-550-9100
Specifications
Parameter
Accuracy Resolution Number of Tank Types Number of Tanks per Tank Type Maximum Tank Depth Minimum Depth Reading Support for Irregularly Shaped Tanks Programmable Tank Capacity Maximum Tank Angle
Value
+/-2% +/-1% 1 16 24 (.61m) 2 (5.08cm) Yes Yes 6 15
Sensor Deadband Fuel (Gasoline only)
Comment
Can be Calibrated for any Shape Tank Allows Displays to Calculate Amount Remaining Without focus tube With focus tube
Standard
NMEA 2000 Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B Tested to IEC 60945 Electromagnetic Compatibility
Description
Periodic Data PGNs
Response to Requested PGNs
PGN #
127505
126464
PGN Name
Fluid Level
PGN List (Transmit and Receive)
Default Rate
0.4 times/second N/A N/A N/A N/A N/A N/A N/A N/A
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA
059904
Protocol PGNs 060928 065240
126208
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
Size Weight Mounting
Value
3.9 x 1.2 x 1.0 (99mm x 30.5mm x 25.4mm) 2.7 dia. X 0.9 (68.6mm dia. x 22.9mm) 8.5 (215.9mm) 12 oz. (340g) SAE J1810 5-hole bolt pattern
Comment
Interface Component Sensor Component Interconnecting Cable Can mount to 1.25 BSP or 1.5 NPT using available adapters
Parameter
IEC 60945 Classification Degree of Protection
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
DSM250 Screen Shots
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
51
TLM200
Maretrons TLM200 is used to sense fluid levels of tanks using ultrasonic technology. Ultrasonic, or sound waves, are transmitted via the TLM200 mounted at the top of the tank and the flight times of the sound waves to and from the fluid are measured much like a depth sensor. What this means for you is that there are no difficult to handle long probes protruding into the tank, which often foul and/ or corrode. Once the TLM200 calculates and broadcast the fluid level over the NMEA 2000 network, you can observe tank levels anywhere on the vessel where there is an NMEA 2000 compatible display such as the Maretron DSM250. The TLM200 is capable of sensing fluid levels in tanks up to 104 (2.64m) in depth. It can be used for diesel, fresh water, waste water, black water, and oil tanks (see the TLM100 for a lower cost solution for tanks up to 40 and the TLM150 for gasoline tanks). Unlike most tank senders that only work with rectangular tanks, the TLM200 can be calibrated for irregular tank shapes so you can know the true fluid level in your tanks. The TLM200 is mounted directly to the top of tanks using the industry standard SAE J1810 5-hole mounting pattern. The TLM200 can also be mounted to tanks with threaded tank openings using optional adapters that include both a 1.5 NPT and a 1.25 BSP adapter. Most importantly, the TLM200 is NMEA 2000 certified so you can view any and all tank levels anywhere on the vessel when using a compatible NMEA 2000 display. The TLM100 is another key component of Maretrons N2KView vessel monitoring and control system.
Products
PART NUMBER TLM200-01 TA-5H-1.25BSP TA-5H-1.5NPT DESCRIPTION Tank Level Monitor (104 Depth Tanks) 1.25 BSP Displacement Hull Tank Adapter 1.5 NPT Displacement Hull Tank Adapter
52
www.maretron.com 1-866-550-9100
Specifications
Parameter
Accuracy Resolution Number of Tank Types Number of Tanks per Tank Type Maximum Tank Depth Minimum Depth Reading Support for Irregularly Shaped Tanks Programmable Tank Capacity Maximum Tank Angle
Value
+/-2% +/-1% 16 16 104 (2.64m) 6 (15.24cm) Yes Yes 6
Sensor Deadband
Comment
Fuel, Fresh Water, Waste water, Live well, Oil, etc. 16 Tanks per Tank Type Numbered 0-15
Can be Calibrated for any Shape Tank Allows Displays to Calculate Amount Remaining
Standard
NMEA 2000 Maritime Navigation and Radio Communication Equipment & Systems FCC and CE mark
Comment
Level B Tested to IEC 60945 Electromagnetic Compatibility
Description
Periodic Data PGNs
Response to Requested PGNs
PGN #
127505
126464
PGN Name
Fluid Level
PGN List (Transmit and Receive)
Default Rate
0.4 times/second N/A N/A N/A N/A N/A N/A N/A N/A
126996
126998 059392
Product Information Configuration Information ISO Acknowledge ISO Request ISO Address Claim ISO Address Command NMEA
059904
Protocol PGNs 060928 065240
126208
Electrical
Parameter
Operating Voltage Power Consumption Load Equivalence Number (LEN) Reverse Battery Protection Load Dump Protection
Value
9 to 16 Volts <100mA 2 Yes Yes DC Voltage
Comment
Average Current Drain NMEA 2000 Spec. (1LEN = 50mA) Indefinitely Energy Rated per SAE J1113
Mechanical
Parameter
Size Weight Mounting
Value
3.9 x 1.2 x 1.0 (99mm x 30.5mm x 25.4mm) 2.6 dia. X 2.0 (66.0mm dia. x 50.8mm) 96 (2.44mm) 15 oz. (425g) SAE J1810 5-hole bolt pattern
Comment
Interface Component Sensor Component Interconnecting Cable Can mount to 1.25 BSP or 1.5 NPT using available adapters
Parameter
IEC 60945 Classification Degree of Protection
Value
Exposed IP67 -25C to 55C -40C to 70C 93%RH @40 per IEC60945-8.2 2-13.2Hz @ 1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 Conducted and Radiated Emission per IEC 60945-9 Conducted, Radiated, Supply, and ESD per IEC 60945-10 Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental
DSM250 Screen Shots
Operating Temperature Storage Temperature Relative Humidity Vibration Rain and Spray Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
53
Field-Attachable Connectors
To Power Source
Multi-Port Box
54
BUS
V+ V-
BUS
V+
V-
SUPPLY
8 amps
8 amps
To Power Source Mini Drop-line to NMEA 2000 Component Multi-Port Box Micro Drop-line to NMEA 2000 Component
Micro bulk cable is primarily used as drop cable, but it can also be used at the trunk line depending on network power requirements. Bulk cable with field-attachable connectors allows for maximum flexibility as cables can be made on the job to exact lengths.
Field-attachable connectors allow you to make field connections to bulk cable (see diagram). The color-coded screw terminals match the individual wire colors found within the bulk cable for error-free field installation.
Like the straight Micro/Mid Fieldattachable Connectors, the 90 field attachable connectors allow you to make field connections to bulk cable. The 90 connectors are particularly well suited for tight spaces like the back of displays where there is limited space for a straight connector.
MICRO/MID
Meets and exceeds NMEA 2000 specifications for the highest reliability Trunk or drop cable for use with Micro connectors Used with field-attachable connectors to build exact length cables at the job site
Color-coded screw terminals make for error-free field installation Rugged housing material designed to withstand harsh marine environments Useful in tight spaces or where sharp corners need to be made Waterproof rated to IP67
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
56
www.maretron.com
BLACK
RED
M12x1
WHITE
.190.015"
BLUE
20.0
20.0
MALE
.285.010"
55 mm 2.17
M12x1
FEMALE
40 mm 1.57
Specifications
20.0
FEMALE
OVERALL
Outer Jacket Mat/Color: Insulation Material: Construction: Shielding (3 Levels): PVC/Gray PE (data wires), SRPVC (power wires) 4x22 (0.65mm) AWG, 22 (0.65mm) AWG Drain FOIL (overall), FOIL (power pair), FOIL (data pair)
DETAIL "A"
LABEL DETAIL
WHITE BLACK
Specifications
MECHANICAL
Housing Mat/Plating: Contact Mat/Plating: Coupling Nut Mat/Plating: Maximum Wire Size: Cable Grip Range: Nylon/Black Brass/Gold Brass/Nickel 18 (1.02mm) AWG 6-8 mm
BLUE
Specifications
MECHANICAL Housing Mat/Plating: Nylon/Black RED GRAY (SCALE 2:1)Contact Mat/Plating: (CONTACT HOLDER Brass/Optaloy REMOVED) Coupling Nut Mat/Plating: Brass/Nickel Maximum Wire Size: 18 (1.02mm) AWG Cable Grip Range: 6-8 mm
POWER PAIR
Wire: Resistance/Conductor: Max Amperage: Color Code: 2X22 (0.65mm) AWG 18.1 Ohms/1000ft 6 Amps Red/Black
DATA PAIR
Wire: Characteristic Impedance: Capacitance: Color Code: 2X22 (0.65mm) (AWG) 120 Ohms 10% 11.33pF/fT 10% White/Blue
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 30 V AC/ 36 V DC
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 30 V AC/ 36 V DC
APPROVALS
UL: CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC-61162-3
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40c TO 85C (-40F to 185F)
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40c TO 85C (-40F to 185F)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC-61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC-61162-3
Products
PART NUMBER CG1 CG1-100 DESCRIPTION Micro Bulk Cable (Per Meter) Micro Bulk Cable (Per 100 Meter Spool-Gray)
Products
PART NUMBER DESCRIPTION FA-CF-ST FA-CM-ST Micro/Mid Field Attachable Connector (Straight Female) Micro/Mid Field Attachable Connector (Straight Male)
Products
PART NUMBER DESCRIPTION FA-CF-90 FA-CM-90 Micro/Mid Field Attachable Connector (90 Female) Micro/Mid Field Attachable Connector (90 Male)
MICRO/MID
Micro Tee
Double-ended cordsets are used for trunk or drop lines and make for a secure connection and simple timesaving installation. The connectors are keyed for error-free connection and they are waterproof for continued operation even while submerged in the bilge.
A Tee is used to tap into the trunk line for adding a drop connection. The standard tee is also available with a cap for a protected diagnostic connection. Tees can be mated with all other devices on the network of the same connector style.
A Powertap Tee is connected to a network backbone just like any Tee but rather than connecting a device their purpose is to provide bus power. Maretron Powertap Tee uniquely provides two power inputs permitting doubled power provision for devices.
MICRO/MID
Gold contacts for greatest reliability Keyed connectors for error-free connections
Rugged, IP68 rated connectors for continued connection integrity in marine environments Various cable lengths to match installation requirements
Yellow cable indicates power and cant be confused with gray network cable Two cable lengths to match installation requirements
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
58
www.maretron.com
55.2 [2.17]
48.5 [1.91]
Micro Tee
15.0 [0.59] M12x1
12x1
M12x1
55.0 [2.17]
15.0 [0.59]
M12x1
15.0 [0.59]
ANTI-VIBRATION DETENT
ANTI-VIBRATION DETENT
7.2 [0.28]
7.2 [0.28] ANTI-VIBRATION DETENT
ANTI-VIBRATION DETENT
M12x1
M12x1
2. Red (Net-S)
M12x1
2. Red (Net-S)
Specifications
MECHANICAL Contact Carrier Mat/Color: Molded Body Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Connector Outside Diameter: Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel 0.59
23.5 [0.92]
ELECTRICAL
Current Rating: Voltage Rating: 4.0 Amps 250 V
Color
Name
NET-C NET-S SHIELD NET-C NET-S
Usage
Ground Power Drain Ground Power
Connector
J1 J1 J1 & J2 J2 J2
CABLE
Outer Jacket Mat/Color: Conductor Insulation Material: Number of Conductors: Shielding (3-Levels): PVC/Gray HDPE (data pair), SRPVC (power pair) MALE END VIEW 4X22 AWG, 22 AWG Drain Wire 4. White FOIL (Overall), FOIL (Power Pair), (Net-H) 3. Black FOIL (Data Pair)
1. Bare (Shield) (Net-C) 5. Blue (Net-L)
ENVIRONMENTAL
Protection Class: Temperature Rating:
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Cable Jacket Mat/Color: Conductor Insulation Mat: Number of Conductors: Thermoplastic PUR/Yellow Thermoplastic PUR/Black Brass/Gold Brass/Nickel PVC/ Yellow PVC 5x18 (1.02mm) AWG
2. Red IEC IP68, NEMA 1,3,4,6P (Net-S) -40C to 80C to (-40F to 176F)
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue PA 6 (Nylon)/Black Brass/Gold Brass/Nickel
5. Blue (Net-L)
APPROVALS
(Cable) UL: (Cable) CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC 61162-3
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 60 V
ELECTRICAL
Voltage Rating: Max Amperage: 250 V 4.0 Amps
Products
PART NUMBER CM-CG1-CF-00.5 CM-CG1-CF-01.0 CM-CG1-CF-02.0 CM-CG1-CF-03.0 CM-CG1-CF-04.0 CM-CG1-CF-05.0 CM-CG1-CF-06.0 CM-CG1-CF-07.0 CM-CG1-CF-08.0 CM-CG1-CF-09.0 CM-CG1-CF-10.0 DESCRIPTION Micro Double-Ended Cordset - M to F - 0.5M (gray) Micro Double-Ended Cordset - M to F - 1M (gray) Micro Double-Ended Cordset - M to F - 2M (gray) Micro Double-Ended Cordset - M to F - 3M (gray) Micro Double-Ended Cordset - M to F - 4M (gray) Micro Double-Ended Cordset - M to F - 5M (gray) Micro Double-Ended Cordset - M to F - 6M (gray) Micro Double-Ended Cordset - M to F - 7M (gray) Micro Double-Ended Cordset - M to F - 8M (gray) Micro Double-Ended Cordset - M to F - 9M (gray) Micro Double-Ended Cordset - M to F - 10M (gray)
ENVIRONMENTAL
Protection Class: Operating Temperature: IEC IP67, NEMA 1,3,4,6 -40C TO 80C (-40F to 176F)
ENVIRONMENTAL
Protection Class: Operating Temperature: IEC IP67, NEMA 1,3,4,6P -40C to 105C (-40F to 221F)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
Products
PART NUMBER CM-CF-CF DESCRIPTION Micro Tee
Products
PART NUMBER CF-SPWR05-CF DESCRIPTION Micro/Mid Powertap Tee - FM (left)/ 5 Meter 4 Wire Power drop (bottom)/FM (right)
MICRO/MID
Two termination resistors are required on every NMEA 2000 network, one on each end of the trunk line. Normally, a male termination is used since male pins tend to point back to the power source. In cases where the gender is reversed, a female terminator may be required. The inline terminator is used where the network is terminated at a product, for example a GPS or weather station at the top of a mast.
MICRO/MID
The Bulkhead Feed-Thru allows ease of installation through panels or bulkheads and establishes future connection points in a network installation. The bulkhead feed-thru also maintains the integrity of watertight bulkheads by providing a waterproof seal and connection.
Multiport boxes allow several drop cables to be consolidated and connected back to the trunk, which eliminates the need to have numerous tees connected near a single point. Multiport boxes connect back to the trunk through a double-ended cordset and Tee.
Features rugged keyways for positive alignment of connections Waterproof rated to IP67
Ideal for consolidating many connections; for example behind dashboards Requires the purchase of an additional double-ended cordset for connection back to the trunk
Screw terminal connector for positive connections Termination resistors are used to terminate both ends of the trunk line
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
60
www.maretron.com
M12x1
GASKET
MALE
48.5 [1.91] 15.0 [0.59]
16.2 [0.64]
3.5 THRU
M12x1
M12x1
M12x1
P1
126.0
M12x1
J1 J2 J3 J4
M12x1
FEMALE
19.4 [0.76]
19.6 [0.77]
17.5 [0.69]
INLINE
MALE END VIEW
4. White (Net-H) 1. Bare (Shield) 2. Red (Net-S) 3. Black (Net-C) 5. Blue (Net-L)
17.0 [0.67]
WIRING DIAGRAM
J1 1 2 3 4 5
J3 1 2 3 4 5
1 2 3 4 5 1 2 3 4 5 J2 1 2 3 4 5 J4
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue-Gray TR-CM, TR-CF Thermoplastic PUR/Black IT-CM-CF Thermoplastic PUR/Blue-Gray TR-CM, TR-CF Thermoplastic PUR/Black IT-CM-CF Brass/Gold Brass/Nickel
Specifications
MECHANICAL Contact Carrier Mat/Color: Contact Mat/Plating: Housing Mat/Plating: Gasket Material: Accommodates Wall (thick): PA 6 (Nylon)/Blue-Gray Brass/Gold Brass/Nickel Nitrile (Buna N) .40 (1.0 mm) to .875 (22.2 mm)
Specifications
MICRO/MID
MECHANICAL Housing Mat/Color: Receptacle Mat/Plating: Contact Carrier Mat/Color: Contact Mat/Plating: Nylon/Blue-Gray Brass/Nickel Nylon/Black Brass/Gold
ELECTRICAL
Rated Voltage: Internal Resistor: 10-30 V DC 120 Ohms (1/2 W) TR-CM, TR-CF 121 Ohms (1/4 W) IT-CM-CF
ELECTRICAL
Voltage Rating: Max Amperage: Number of Conductors: 250 V 4.0 Amps 5x22 (0.65mm) AWG
ELECTRICAL
Operating Voltage: Operating Current: 250 V 4.0 Amps 250 V
ENVIRONMENTAL
Protection Class: IEC IP68, NEMA 1,3,4,6P
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4,6 -40C to 105C (-40F to 221F)
ENVIRONMENTAL
Protection Class: Operating Temperature: IP67 when receptacles are covered -30C to 80C (-22F to 176F)
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
Products
PART NUMBER TR-CM TR-CF IT-CM-CF DESCRIPTION Micro Termination Resistor (Male) Micro Termination Resistor (Female) Micro Inline Terminator
Products
PART NUMBER BHF-CM-CF DESCRIPTION Micro Bulkhead Feed-Thru
Products
PART NUMBER CM-CF-4 DESCRIPTION Multiport Box (Micro-Mid Male Homerun / Micro-Mid Female Drops)
Mid bulk cable is primarily used as drop cable, but it can also be used at the trunk line depending on network power requirements. Bulk cable with field-attachable connectors allows for maximum flexibility as cables can be made on the job to exact lengths.
Double-ended cordsets are used for trunk or drop lines and make for a secure connection and simple timesaving installation. The connectors are keyed for error-free connection and are waterproof for continued operation even while submerged in the bilge.
Double-ended cordsets are used for trunk or drop lines and make for a secure connection and simple timesaving installation. The connectors are keyed for error-free connection and are waterproof for continued operation even while submerged in the bilge.
MICRO/MID
Meets and exceeds NMEA 2000 specifications for the highest reliability Used with field-attachable connectors to build exact length cables at the job site Optimized for voltage drop sensitive networks (long runs) because power pair wires have half the resistance of Micro cable
Rugged, IP68 rated connectors for continued connection integrity in marine environments Various cable lengths to match installation requirements Optimized for voltage drop sensitive networks (long runs) because power pair wires have half the resistance of Micro cable
Rugged, IP68 rated connectors for continued connection integrity in marine environments Various cable lengths to match installation requirements Optimized for voltage drop sensitive networks (long runs) because power pair wires have half the resistance of Micro cable
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
62
www.maretron.com
WHITE
15.0 [0.59] 15.0 [0.59]
BLUE
4. White (Net-H)
RED
Specifications
.330.005"
Specifications
Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel 0.59
MECHANICAL Contact Carrier Mat/Color: Molded Body Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Connector Outside Diameter:
MECHANICAL Contact Carrier Mat/Color: Molded Body Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Connector Outside Diameter:
Specifications
ELECTRICAL
Current Rating: Voltage Rating: 4.0 Amps 250 V
ELECTRICAL
Current Rating: Voltage Rating: 4.0 Amps 250 V
OVERALL
Outer Jacket Mat/Color: Insulation Material: Construction: Shielding (3 levels): POWER PAIR Wire: Resistance/Conductor: Max Amperage: Color Code: PVC/Gray DG1 PVC/Blue DB1 PE (data wires), PVC (power wires) 2x16 (1.29mm) AWG, 2x20 (0.81mm) AWG, 20 (0.81mm) AWG Drain Wire Foil (overall), Foil (power pair), Foil (data pair) 2x16 (1.29mm) AWG 4.1 Ohms/1000 ft max 14 Amps Red/Black
CABLE
Outer Jacket Mat/Color: Conductor Insulation Material: Number of Conductors: Shielding (3 Levels): PVC/Gray PE (data pair), PVC (power pair) 2x16 (1.29mm) AWG, Data 2x20 (0.81mm) AWG, 20 (0.81mm) AWG Drain Wire Alum/Polyester Foil (Overall), Foil (Power Pair), Foil (Data Pair)
CABLE
Outer Jacket Mat/Color: Conductor Insulation Material: Number of Conductors: Shielding (3 Levels): PVC/Blue PE (data pair), PVC (power pair) 2x16 (1.29mm) AWG, 2x20 (0.81mm) AWG, 20 (0.81mm) AWG Drain Wire Foil (Overall), Foil (Power Pair), Foil (Data Pair)
ENVIRONMENTAL
Protection Class: Temperature Rating: IEC IP68, NEMA 1,3,4,6P -40C to 80C to (-40F to 176F)
ENVIRONMENTAL
Protection Class: Temperature Rating: IEC IP68, NEMA 1,3,4,6P -40C to 80C to (-40F to 176F) PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC 61162-3
PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC 61162-3
APPROVALS
UL: CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC-61162-3
Products
PART NUMBER DM-DG1-DF-00.5 DM-DG1-DF-01.0 DM-DG1-DF-02.0 DM-DG1-DF-03.0 DM-DG1-DF-04.0 DM-DG1-DF-05.0 DM-DG1-DF-06.0 DM-DG1-DF-07.0 DM-DG1-DF-08.0 DM-DG1-DF-09.0 DM-DG1-DF-10.0 DESCRIPTION Mid Double-Ended Cordset - M to F - 0.5M (gray) Mid Double-Ended Cordset - M to F - 1M (gray) Mid Double-Ended Cordset - M to F - 2M (gray) Mid Double-Ended Cordset - M to F - 3M (gray) Mid Double-Ended Cordset - M to F - 4M (gray) Mid Double-Ended Cordset - M to F - 5M (gray) Mid Double-Ended Cordset - M to F - 6M (gray) Mid Double-Ended Cordset - M to F - 7M (gray) Mid Double-Ended Cordset - M to F - 8M (gray) Mid Double-Ended Cordset - M to F - 9M (gray) Mid Double-Ended Cordset - M to F - 10M (gray)
Products
PART NUMBER DM-DB1-DF-00.5 DM-DB1-DF-01.0 DM-DB1-DF-02.0 DM-DB1-DF-03.0 DM-DB1-DF-04.0 DM-DB1-DF-05.0 DM-DB1-DF-06.0 DM-DB1-DF-07.0 DM-DB1-DF-08.0 DM-DB1-DF-09.0 DM-DB1-DF-10.0 DESCRIPTION Mid Double-Ended Cordset - M to F - 0.5M (blue) Mid Double-Ended Cordset - M to F - 1M (blue) Mid Double-Ended Cordset - M to F - 2M (blue) Mid Double-Ended Cordset - M to F - 3M (blue) Mid Double-Ended Cordset - M to F - 4M (blue) Mid Double-Ended Cordset - M to F - 5M (blue) Mid Double-Ended Cordset - M to F - 6M (blue) Mid Double-Ended Cordset - M to F - 7M (blue) Mid Double-Ended Cordset - M to F - 8M (blue) Mid Double-Ended Cordset - M to F - 9M (blue) Mid Double-Ended Cordset - M to F - 10M (blue)
Products
PART NUMBER DG1 DG1-100 DB1 DB1-100 DESCRIPTION Mid Bulk Cable (Per Meter-Gray) Mid Bulk Cable (Per 100 Meter Spool-Gray) Mid Bulk Cable (Per Meter-Blue) Mid Bulk Cable (Per 100 Meter Spool-Blue)
MICRO/MID
APPROVALS
APPROVALS
Some products use inexpensive nylon connectors and when connected with metal connectors, the nylon threads can be damaged. This cable eliminates the problem by allowing nylon to nylon connections and metal to metal connections.
A 90 degree male to female connector for Micro or Mid size cable runs or connections which is intended to aid turning tight radiuses without unduly straining the wires within a cable. Ideal when mounting a device in a location with shallow depth possibilities.
This 25 meter length Mid size cable with a Micro female connector on one end is intended for installation of devices such as Maretrons WSO100 Weather Station.The female connector should point towards the device and a field attachable male connector should be made onto the end connecting to the rest of the backbone.
MICRO/MID
NMEA 2000 Approved Waterproof rated to IP67 NMEA 2000 Approved Meets ABYC Power Pair size requirements Waterproof rated to IP67
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
64
www.maretron.com
M12x1
M12x1
M12x1
J1
9.5 [0.37]
J1 QUICK-CONNECT COUPLING
2. Red (+Voltage)
M12x1
J1
P1
M12x1
Specifications
MECHANICAL Molded Head Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Snap-Lock Mat/Color: Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Black Brass/Gold POM/Black
Specifications
MECHANICAL Molded Head Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Snap-Lock Mat/Color: Thermoplastic PUR/Black Thermoplastic PUR/Blue-Gray Brass/Gold POM/Black
2. Red
5. Blue
5. Blue 2. Red
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 250 V
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Gray Nylon PUR Brass/Gold Brass/Nickel
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 250 V
CABLE
Outer Jacket Mat/Color: Conductor Insulation Mat: Number of Conductors: Shielding (3-Levels): PVC/Gray HDPE (Data), SRPVC (Power Pair) 4X22 (0.65mm) AWG, 22 (0.65mm) AWG Drain Wire Foil (Overall), Foil (Power Pair), Foil (Data Pair)
CABLE
Outer Jacket Mat/Color: Conductor Insulation Mat: Number of Conductors: Shielding (3-Levels): PVC/Gray HDPE (Data), SRPVC (Power Pair) 4X22 (0.65mm) AWG, 22 (0.65mm) AWG Drain Wire Foil (Overall), Foil (Power Pair), Foil (Data Pair)
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 50 V
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40C to 80C (-40F to 176F)
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4,6P -40C to 105C (-40F to 221F)
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40C to 80C (-40F to 176F)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
Products
PART NUMBER QCM-CG1-QCF-01 DESCRIPTION Nylon to Metal Connector Cable
Products
PART NUMBER ELB-CM-CF DESCRIPTION Micro 90 Male to Female Connector
Products
PART NUMBER DF-DB1-25.0 DESCRIPTION Mid Single-Ended Cordset Female to Open Pigtail 25 Meter (blue)
MICRO/MID
Mini bulk cable is primarily used as trunk cable, but it can also be used as drop lines. Bulk cable with fieldattachable connectors allows for maximum flexibility as cables can be made on the job to exact lengths.
Field-attachable connectors allow you to make field connections to bulk cable. The color-coded screw terminals match the individual wire colors found within the bulk cables for error-free field installation.
Double-ended cordsets are used for trunk or drop lines and make for a secure connection and simple timesaving installation. The connectors are keyed for error-free connection and are waterproof for continued operation even while submerged in the bilge.
Meets and exceeds NMEA 2000 specifications for the highest reliability Trunk or drop cable for use with Mini connectors Used with field-attachable connectors to build exact length cables at the job site
Color-coded screw terminators make for error-free field installation Rugged housing material designed to withstand harsh marine environments
Rugged, IP68 rated connectors for continued connection integrity in marine environment Various cable lengths to match installation requirements
MINI
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
66
www.maretron.com
7/8-16UN
WHITE
7/8-16UN
7/8-16UN
.295.015"
BLACK
RED
FEMALE
88.0 [3.46] 27.0 [1.06]
.390.010"
7/8-16
Specifications
MECHANICAL Contact Carrier Mat/Color: Molded Head Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Connector Outside Diameter: Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel 1.06
MALE
Specifications
OVERALL
Outer Jacket Mat/Color: Insulation Material: Construction: Shielding (3 Levels): PVC/Blue NB1 PVC/Gray NG1 PE (data), PVC (power) 2x15 (1.45mm) AWG, 2x18 (1.02mm) AWG, 18 (1.02mm) AWG Drain Wire Foil (overall), Foil (power pair), Foil (data pair)
ELECTRICAL
Current Rating: Voltage Rating: 9.0 Amps 300 V
POWER PAIR
Wire: Resistance/Conductor: Max Amperage: Color Code: 2x15 (1.45mm) AWG 3.44 Ohms/1000 ft max 16 Amps NB1 14 Amps NG1 Red/Black
Specifications
MECHANICAL
Housing Mat/Color: Contact Mat/Plating: Coupling Nut Material: Maximum Wire Size: Termination Method: Glass Filled Nylon/Black Brass/Gold Anodized Aluminum 16 (1.29mm) AWG Screw Terminal
CABLE Outer Jacket Mat/Color: Conductor Insulation Material: Number of Conductors: Shielding (3-Levels):
PVC/Gray PE (data pair), PVC (power pair) Power 2x15 (1.45mm) AWG, 2x18 (1.02mm) AWG, 18 (1.02mm) AWG Drain Wire Braid (Overall), Foil (Power Pair), Foil (Data Pair)
ENVIRONMENTAL
Protection Class: Temperature Rating: IEC IP68, NEMA 1,3,4,6P -40C to 80C (-40F to 176F)
APPROVALS
(Cable) UL: (Cable) CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC 61162-3
ELECTRICAL
Rated Current: Rated Voltage: 9.0 Amps 250 Volts
APPROVALS
UL: CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 APPROVED IEC-61162-3
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40c TO 85C (-40F to 185F)
Products
PART NUMBER NM-NG1-NF-00.5 NM-NG1-NF-01.0 NM-NG1-NF-02.0 NM-NG1-NF-03.0 NM-NG1-NF-04.0 NM-NG1-NF-05.0 NM-NG1-NF-06.0 NM-NG1-NF-07.0 NM-NG1-NF-08.0 NM-NG1-NF-09.0 NM-NG1-NF-10.0 DESCRIPTION Mini Double-Ended Cordset - M to F - 0.5M (gray) Mini Double-Ended Cordset - M to F - 1M (gray) Mini Double-Ended Cordset - M to F - 2M (gray) Mini Double-Ended Cordset - M to F - 3M (gray) Mini Double-Ended Cordset - M to F - 4M (gray) Mini Double-Ended Cordset - M to F - 5M (gray) Mini Double-Ended Cordset - M to F - 6M (gray) Mini Double-Ended Cordset - M to F - 7M (gray) Mini Double-Ended Cordset - M to F - 8M (gray) Mini Double-Ended Cordset - M to F - 9M (gray) Mini Double-Ended Cordset - M to F - 10M (gray)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC-61162-3
Products
PART NUMBER NG1 NG1-100 NB1 NB1-100 DESCRIPTION Mini Bulk Cable (Per Meter-Gray) Mini Bulk Cable (Per 100 Meter Spool-Gray) Mini Bulk Cable (Per Meter-Blue) Mini Bulk Cable (Per 100 Meter Spool-Blue)
Products
PART NUMBER FA-NF-ST FA-NM-ST DESCRIPTION Mini Field Attachable Connector (Female) Mini Field Attachable Connector (Male)
MINI
Mini Tees
Double-ended cordsets are used for trunk or drop lines and make for a secure connection and simple timesaving installation. The connectors are keyed for error-free connection and are waterproof for continued operation even while submerged in the bilge.
A Tee is used to tap into the trunk line for adding a drop connection. Two Mini Tees are available: 1) a Mini Tee with Mini connectors for the trunk and drop lines, and 2) a Mini/Micro Tee with Mini connectors for the trunk lines and a Micro connector for the drop line.
A Powertap is connected to a network backbone just like any Tee but rather than connecting a device, its purpose is to provide bus power. Typically a Powertap is placed as central as possible between total devices on backbone. Maretron Powertap uniquely provides two power inputs permitting doubled power provision for devices. Connects power supply to NMEA 2000 Trunk Line in convenient plug/play fashion Replaceable fuses to protect bus and connected components from excessive current
Rugged, IP67 rated connectors for continued connection integrity in marine environment Various cable lengths to match installation requirements
Gold Contacts for greatest reliability Keyed connectors for error-free connections
MINI
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
68
www.maretron.com
Mini Tees
CLEARANCE FOR #8 (M4) FASTENER
27.0 [1.06]
7/8-16UN
7/8-16UN
7/8-16UN
7/8-16UN
2.52 [64.0]
1.42 [36.0]
BUS
BUS
2.05 [52.0]
SUPPLY
NF
SHIELD M4 OR .138-32 SOCKET CONNECTION HEAD SCREW 16 MM MINIMUM (2) NOT INCLUDED
65.0 [2.56]
BOTTOM VIEW
17.5 [0.69]
27.0 [1.06]
11.0 [0.43]
Color
Name
Usage
Connector
Specifications
28.0 [1.10]
V-1 & V-2 V+1 & V+2 V-1 & V-2 V+1 & V+2
MECHANICAL Contact Carrier Mat/Color: Molded Body Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Connector Outside Diameter:
17.5 [0.69]
Specifications
ELECTRICAL Operating Voltage: Protection Circuit: Schottky Rectifier: Bus Line Minimum Conductor: Supply Line Minimum Conductor:
7/8-16 UN
NF-NM4P-NF
25 V min Slo-Blo Fuse: 8 Amps, 250 V Metric Fuse Block: 5x20 mm Trip Time: 4 sec Min to 100 sec max Type: MBR 3045PT Max: Reverse Voltage VRWM=45 V Max: Average Fwd Cur IFRM=30 Amps Peak Surge Cur t=8.3 sec., IFSM=200 Amps Max Vf = 0.65 V @ 125C and IF=20 Amps 16 AWG 8 Amps (Mini 5-Pin) 16 AWG 8 Amps (Mini 4-Pin)
ELECTRICAL
Current Rating: Voltage Rating: 9.0 Amps 300 V
26.0 [1.02]
CF
73.0 [2.87]
CABLE Outer Jacket Mat/Color: Conductor Insulation Material: Number of Conductors: Shielding (3-Levels):
17.5 [0.69]
37.4 [1.47]
PVC/Blue PE (data pair), PVC (power pair) 2x15 (1.45mm) AWG, 2x18 (1.02mm) AWG, 18 (1.02mm) AWG Drain Wire Braid (Overall), Foil (Power Pair), Foil (Data Pair)
31.5 [1.24]
ENVIRONMENTAL
Temperature Range: Storage Temperature: -40C to 70C (-40F to 158F) -40C to 85C (-40F to 185F)
26.0 [1.02]
ENVIRONMENTAL
Protection Class: Temperature Rating: IEC IP67, NEMA 1,3,4,6P -40C to 80C (-40F to 176F)
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
APPROVALS
(Cable) UL: (Cable) CSA: NMEA: IEC: PLTC 75C Sunlight Resistant E90625, AWM 80C 300V CMX-OUTDOOR-CMG LL54185 75C, AWM I/II A/B 80C 300V FT4 NMEA 2000 Approved IEC 61162-3
ELECTRICAL
Rated Current: Rated Voltage: 9.0 Amps NM-NF-NF 4.0 Amps (Micro) 9.0 Amps (Mini) NM-CF-NF 600 V NM-NF-NF 250 V NM-CF-NF 250 V NM-CF-NF IEC IP67, NEMA 1,3,4,6P -40C to 80C (-40F to 176F)
MECHANICAL Molded Body Mat/Color: Outer Jacket Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Conductor Insulation Mat:
NM4P-01, NM4P-05
Thermoplastic PUR/Yellow PVC/Yellow Thermoplastic PUR/Yellow Brass/Gold Brass/Nickel PVC
ELECTRICAL
Conductors: Current Rating: Voltage Rating: 4x16 (1.29mm) AWG 9.0 Amps 600 V
Products
PART NUMBER NM-NB1-NF-00.5 NM-NB1-NF-01.0 NM-NB1-NF-02.0 NM-NB1-NF-03.0 NM-NB1-NF-04.0 NM-NB1-NF-05.0 NM-NB1-NF-06.0 NM-NB1-NF-07.0 NM-NB1-NF-08.0 NM-NB1-NF-09.0 NM-NB1-NF-10.0 DESCRIPTION Mini Double-Ended Cordset - M to F - 0.5M (blue) Mini Double-Ended Cordset - M to F - 1M (blue) Mini Double-Ended Cordset - M to F - 2M (blue) Mini Double-Ended Cordset - M to F - 3M (blue) Mini Double-Ended Cordset - M to F - 4M (blue) Mini Double-Ended Cordset - M to F - 5M (blue) Mini Double-Ended Cordset - M to F - 6M (blue) Mini Double-Ended Cordset - M to F - 7M (blue) Mini Double-Ended Cordset - M to F - 8M (blue) Mini Double-Ended Cordset - M to F - 9M (blue) Mini Double-Ended Cordset - M to F - 10M (blue)
ENVIRONMENTAL
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4,6P -40C to 105C (-40F to 221F)
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
Products
PART NUMBER NM-NF-NF NM-CF-NF DESCRIPTION Mini Tee Mini/Micro Tee
Products
PART NUMBER NF-NM4P-NF NM4P-01 NM4P-05 DESCRIPTION Mini Powertap - Female-Female with Fuses Mini Power Cord - Female to Pigtail - 1 Meter Mini Power Cord - Female to Pigtail - 5 Meter
MINI
Termination Resistors are required on a NMEA 2000 network and are placed at each end of a network trunk cable. Like the double-ended cordsets, the termination resistors are waterproof and continue to function even while submerged in the bilge.
The Mini Elbow is used in spots where it is impossible to bend a cordset around tight corners. The elbow easily connects to a tee or double-ended cordsets making 90 [degree] turns practical at the end or anywhere along the line.
The reducer is used to change from a Mini cable to Micro or Mid cable. For example, one end of the network might be terminated at the top of the mast but it may not be desireable to run a Mini trunk cable up the mast. In this case, you can switch over to Micro or Mid cable at the base of the mast using the reducer and continue up the mast with Micro or Mid cable.
Diagnostic versions indicate correct polarity at a glance to ensure power connections have been made properly Screw connector for positive connnection Termination resistors are used to terminate both ends of the trunk line
Mounting hole for secure fastening of cabling system Waterproof seals for reliable connections Nickel plated brass ideally suited for harsh marine environment Corrosion resistant Nickle plated Brass Weatherproof to IP67 Reduces Mini Backbone to Micro/ Mid Cable
MINI
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
70
www.maretron.com
P1
MALE
7/8-16UN
1.024 [26.0]
36.0 [1.42]
63.4 [2.50]
46.6 [1.83] 26.0 [1.02]
1.024 [26.0] 7/8-16UN
FEMALE
7/8-16UN
J1
1.102 [28.0]
M12x1
18.1 [0.71]
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue-Gray TR-NM, TR-NF Thermoplastic PUR/Clear TRL-NM, TRL-NF Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel
17.5 [0.69]
38.2 [1.50]
2. Red (Net-S) 3. Black (Net-C) 4. White (Net-H)
ELECTRICAL
Rated Voltage: Internal Resistor: Voltage Monitoring: (Bus Power) 300 V DC 120 Ohms (1/2 W) Green: Correct Polarity Red: Reversed Polarity TRL-NM, TRL-NF
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue Thermoplastic PUR/Blue Brass/Gold Brass/Nickel
Specifications
Contact Mat/Plating: Coupling Nut Mat/Plating: Brass/Gold Brass/Nickel
ENVIRONMENTAL
Protection Class: Temperature Rating: IEC IP67, NEMA 1,3,4,6, 13 -40C to 80C (-40F to 176F)
ELECTRICAL
Rated Current: Rated Voltage: 9.0 Amps 600 V
ELECTRICAL
Rated Current: Rated Voltage: 4.0 Amps 250 V
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4,6 P -40c TO 80C (-40F to 176F)
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4 -40c TO 75C (-40F to 167F)
Products
PART NUMBER TR-NM TR-NF TRL-NM TRL-NF DESCRIPTION Mini Termination Resistor (Male) Mini Termination Resistor (Female) Mini Termination Resistor with LED (Male) Mini Termination Resistor with LED (Female)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 APPROVED IEC 61162-3
Products
PART NUMBER ELB-NM-NF DESCRIPTION Mini 90 Male to Female Connector
Products
PART NUMBER NM-CF DESCRIPTION Mini Male to Micro Female Reducer
MINI
MECHANICAL
N2KMeter
Maretron cables have a male connector on one end and a female connector on the other end. Normally, the male connector points back towards the network power supply, but on some occasions, this gets reversed and a gender changer can be used to get back to the desired connector type.
The Bulkhead Feed-Thru allows ease of installation through panels or bulkheads and establishes future connection points in a network installation. The bulkhead feed-thru also maintains the integrity of watertight bulkheads by providing a waterproof seal and connection.
The N2KMeter enables trained and untrained personnel to diagnose and trouble-shoot network installations quickly and easily. Completely passive on the network, the meter analyzes both data and power lines on the network. In seconds, both networkwide and device-specific traffic as well as power monitoring information is captured and displayed on a simple user interface.
MINI
Waterproof seals for reliable connections Easily swap connector gender to get back to desired connector type
Features rugged keyways for positive alignment of connections Waterproof rated to IP67 Diagnostic tool for NMEA 2000 networks Evaluates physical layer device functions on a network Data at boat can be locked in and then evaluated later on bench
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
72
www.maretron.com
N2KMeter
Electrician Mode (Simple)
1. Plug in and set N2KMeter rotary switch to autosearch 2. Identify network health Happy face = healthy
7/8-16 UN
7/8-16 UN
7/8-16UN
28.0 [1.10]
7/8-16UN
17.5 [0.69]
LOCKNUT
19.2 [0.76]
3. Scroll through faults. Refer to user manual to link these faults to most likely network problems or freeze and lock settings for review back at the shop by an NMEA 2000 expert.
26.0 [1.02]
27.0 [1.06]
7/8-16UN
7/8-16UN
30.4 [1.20]
Neutral face = very close to limit Sad face = out of limit 3.Refer to user manual to link these faults to most likely network problems
18.7 [0.74]
Specifications
MECHANICAL Molded Body Mat/Color: Contact Carrier Mat/Color: Contact Mat/Plating: Coupling Nut Mat/Plating: Thermoplastic PUR/Blue-Gray Thermoplastic PUR/Blue-Gray Brass/Gold Brass/Nickel
Specifications Specifications
MECHANICAL Contact Carrier Mat/Color: Housing Mat/Plating: Contact Mat/Plating: Gasket Material: Accommodates Wall (thick): Thermoplastic PUR/Blue-Gray Brass/Nickel Brass/Gold Nitrile (Buna N) .040 (1.0 mm) to .875 (22.2 mm)
MECHANICAL
Power Supply: Connectors: Band Rates: Analog Accuracy: Analog Range: Analog Sample Rate: Signal Error Threshold: Bus Load Measurement: Bus Message Rate Measurement: Error Rate Measurement: Network 7 - 30v DC < 90MA Batteries 2 X AA Alkaline Batteries 6 Hours Of Operation Approx. 1 Year Data Retention Micro Connector 125k, 250k and 500k (Auto-detect) Bus Power100mv, Bus Signal20mv Bus Power 0 to 25v with over/under Range Indication Bus signal -5 To 10v with over/under range Indication Bus Power 1 Khz Bus Signal Ideal Sample Pt250ns NMEA 2000 Spec for Network Power Detects Bus Idle In Real Time Detects 100% of Individual Can Frames in Real Time Detects 100% of Individual Error Frames in Real Time
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67, NEMA 1,3,4,6P NM-NM IEC IP67, NEMA 1,3,4,13 NF-NF -40C to 70C (-40F to 158F) NM-NM -40C to 55C (-40F to 131F) NF-NF
ELECTRICAL
Voltage Rating: Max Amperage: Number of Conductors: 600 V 9.0 Amps 5x22 AWG (0.65mm)
ENVIRONMENTAL
Protection Class: Temperature Range: IEC IP67 -40C to 105C (-40F to 221F)
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: IEC: NMEA 2000 Approved IEC 61162-3
APPROVALS
NMEA: NMEA 2000 Approved
Products
PART NUMBER NM-NM NF-NF DESCRIPTION Mini Gender Changer (Male/Male) Mini Gender Changer (Female/Female)
Products
PART NUMBER BHF-NM-NF DESCRIPTION Mini Bulkhead Feed-Thru
Products
PART NUMBER N2KMETER-01 DESCRIPTION Diagnostic Meter w/1m Micro Cordset
MINI
ELECTRICAL
Please note that this installation guide contains a brief description of the basic concepts of installing an NMEA 2000 network and Maretron suggests that you consult a trained professional for any installation. You can learn more about installing NMEA 2000 networks by contacting the National Marine Electronics Association (NMEA) at www.nmea.org and consulting the following documents:
Figure 1
74
Figure 2
opposed to Micro cable (4 amps). Mini cable has an outside diameter in the range from 0.41 to 0.49 inches. Its maximum installed bend radius is 7x the cable diameter. You can also use this type of cable for drop lines. Mid - This is commonly used for smaller networks as either the network trunk line or as drop lines. Mid cable and connectors are rated to 4 amps just like the Micro cable, however the larger diameter power conductors within the Mid cable provides for less voltage drop over Micro cable, especially for long runs. The diameter of the Mid cable is 0.33 inches. Micro - This cable type is typically used as the drop line connecting devices to the main trunk line with an outside diameter in the range from 0.24 to 0.28 inches. Micro cable has a smaller diameter and is more flexible than mini cable with an installation bend radius of 7x the cable diameter. Smaller networks use this type of cable for both the trunk and drop lines. You construct the trunk line using double-ended cordsets connected between tees or taps. One end of the cordset has a male connector with male pins while the other end of the cordset has a female connector and female receptacles. The connectors are keyed so they can only connect to each other in one way. As an alternative to double-ended
cordsets, you can make your own trunk line using bulk cable and field-attachable connectors. If you decide to add equipment later, you can simply disconnect a cordset from a tee, add another tee directly to the existing tee, re-connect the cordset and add the new component to the system using a drop cable. Alternatively, you could cut the trunk line, add two field-attachable connectors and insert a new tee. Trunk lines can also be run up to watertight bulkheads and connected to a waterproof bulkhead feed-thru connector to maintain the integrity of watertight compartments. To drop off the trunk line, you connect a device using a tee connector. Daisy chaining of devices is not allowed, as it is a requirement to be able to remove a component from the network without affecting any other device. This allows you to remove a device for servicing while the rest of the network remains operational. Multi port boxes are also available where instruments tend to be clustered, around the helm for example.
For most cases, the maximum distance should be measured between termination resistors. However, if the distance from a trunk line tee to the farthest device connected to the trunk line is greater than the distance from the tee to the nearest terminating resistor (TR), then you MUST include the drop line length as part of the cable length in your maximum cable distance calculation. Figure 2 shows an example where both 5 meter drops must be included in the maximum cable distance since the drops are longer than the distance from the tee to termination resistor.
A maximum of 50 physical devices shall be connected to the network, and the disconnection of any device shall not interrupt any other device on the network.
Figure 3
76
Figure 4
Mini Powertap
Figure 5
Micro/Mid Powertap
3. Supplying Power
NMEA 2000 networks can use a power supply originating from a single-point connection to the vessels 12 volt battery or one or more isolated power supplies distributed along the network, but not a combination of battery and power supply connections. For the purpose of this installation guide, we will focus on the power source being a single-point connection to the vessels battery. Over current protection should be provided and should be sized in accordance with ABYC E-11, AC and DC ELECTRICAL SYSTEMS ON BOATS, taking into consideration the smallest gauge of cable being used for the backbone or drop cables. The NET-S wire is connected to the positive side of the battery while NET-C is connected to the negative side of the battery.
2. Installing Terminators
Termination resistors are attached to each end of the trunk cable to reduce reflections of the communication signals on the network. If you do not use termination resistors as described, the network will not operate properly. Termination resistors are typically connected directly to the last tee on the trunk line although they can be connected to a cordset extending from the last tee on a trunk line. Inline terminators are also available and they are used to terminate the network at the last product.
Powertap can handle large loads as long as no more than 8 amps is drawn through any single segment of the trunk line. However, cable resistance may limit your application to less than 8 amps.
network consists of two legs, one leg extending in each direction from the power insertion point. Figure 7 shows a middle-powered network.
Power supply voltage drop estimates resulting in less than 1.5 volts across the entire network require no further analysis. Likewise, estimates ranging between 1.5 and 3.0 volts require no further analysis as long as a mid-powered network is used. Occasionally, estimated power supply voltage drops will occur outside these limits and will require further consideration through detailed calculations by certified technicians.
Electronic Compass Trunk Line Depth Sounder 0.3 meter 2 loads Compass Display 0.3 meter 2 loads 2 meters 1 load Drop Line Device or Node
TR
5 meters 2 meters 1 load Autopilot
TR
10 meters
.03 meter
2 meters
TR
Drop Tee
Figure 6
End-Powered Network
78
Speed Log Trunk Line 0.3 meters 2 loads 0.3 meters 0.3 meters Drop Line Device or Node
TR
TR
0.3 meter 2 loads
TR
Drop Tee
Depth Repeater
Figure 7
Middle-Powered Network
location. Grounding at more than one location may produce ground loops, which can cause problems with communications on the network. In addition to the ground wire, connect the drain or SHIELD wire at the supply ground location and NO other place.
More or less than two terminating resistors Loose connections, make sure that all connectors are securely fastened Excessive trunk line length-especially with Micro cable Excessive drop line cable length Improper shield and ground connection at the power supply Shorts and opens in field-attachable connectors Failure to perform power distribution calculations for new installations and when adding new devices Using a typical device current rather than maximum current for power distribution calculations In order to insure the proper installation and configuration of an NMEA 2000 network, it is a good idea to have available at least one N2KMeter. The N2KMeter greatly simplifies network diagnostics and can detect many fault conditions including: Opens and shorts Incorrect topology Bad nodes Bad termination Improper shield connection Intermittent problems Excessive scan rate Common mode voltage 79
N2KBuilder
N2KBuilder software is a powerful, free PC-based tool for designing and verifying the integrity of NMEA 2000 networks. The N2KBuilder software, when installed on a Windows PC and used as part of an integrated design workflow can be used to plan, document, and validate the design of complex NMEA 2000 networks. In addition, N2KBuilder will directly produce a Bill of Materials (BOM) for Maretron products, eliminating guesswork and transcription errors.
80
www.maretron.com 1-866-550-9100
N2KAnalyzer is a software tool, currently offered free of charge with the purchase of a USB100 NMEA 2000/USB gateway, which gives you a detailed view of all of the devices on a NMEA 2000 network, and lets you perform an enormous variety of configuration and troubleshooting tasks. All you need is a PC running Windows and a Maretron USB100 NMEA 2000 gateway.
N2KAnalyzer
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretrons products are designed to be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A prudent captain or navigator never relies on a single source for navigation or system monitoring information. NMEA 2000 is a registered trademark of the National Marine Electronics Association.
81
10
Email: sales@maretron.com Web: www.maretron.com
Maretron Corporate Office 9014 N. 23rd Avenue, Suite 10 Phoenix, AZ 85021 Toll Free: 866-550-9100 Phone: 602-861-1707 Fax: 602-861-1777
www.maretron.com