SERIES 300
SPECIFICATIONS
For Gen Set Applications
Power Units
STANDBY POWER
Performance Data
PRIME POWER
1500 rpm
1800 rpm
69(92)
76(102)
1800
No
1164(169)
1296(188)
18(24)
1525(5000)
24.0: 1
22.0 :1
91.1
91.3
Prime = PRP
1500 rpm
1800 rpm
Standby = LTP
Prime = PRP
General Data
Model .........................................................4039TF
Number of cylinders ...................................4
Bore and Stroke - mm (in.) ........................106 x 110 (4.19 x 4.33)
Displacement - dm' (in') .............................3.9(239)
Compression Ratio ....................................17.8 :1
Valves per Cylinder - Intake/Exhaust .........1 / 1
Firing Order ...............................................1-3-4-2
Combustion System ..................................Direct Injection
Engine type ...............................................In-line, 4-cycle
Aspiration ..................................................Turbocharged
Engine Crankcase Vent System ................Open
Engine Crankcase Pressure - kPa (in.H20) ............................ 0.5(2)
Physical Data
Length - mm (in.) ............................................................ 1016(40.0)
Width - mm (in.) ................................................................ 588(23.1)
Height - mm (in.) ............................................................... 960(37.8)
Weight, dry - kg (Ib) ......................................................... 488(1076)
(includes flywheel housing, flywheel, & electrics)
Center of gravity location
From Rear Face of block (X-axis) - mm (in.) .................... 300(11.8)
Right of Crankshaft (Y-axis) - mm (in.) ...............................-18(-0.7)
Above Crankshaft (Z-axis) - mm (in.) .................................. 149(5.8)
Electrical Data
Recommended Battery Capacity (CCA)
12 Volt System - Amp .................................................................640
24 Volt System - Amp .................................................................570
Maximum Allowable Starting Circuit Resistance
12 Volt System - Ohm ...........................................................0.0012
24 Volt System - Ohm .............................................................0.002
Starter Rolling Current - 12 Volt System
At O'C (32'F) - Amp ....................................................................780
At -30'C (-22oF) - Amp .............................................................1000
Starter Rolling Current - 24 Volt System
At O'C (32'F) - Amp ....................................................................600
At -30'C (-22'F) - Amp .................................................................700
Standby = LTP
. ~ ................... 5.5
...................... . 10.5
...................... . 14.5
...................... . 19.0
Air System
Fuel System
Stanadyne
5%
Lubrication System
345(50)
105(15)
115(240)
12(12.7)
.......................... ... 20
20