Anda di halaman 1dari 4

NRL

Air cooled chillers with axial flow fans


Cooling capacity from 174 kW up to 469 kW

R410A

Aermec adheres to the


EUROVENT Certification
Programme.
The products concerned
appear in the EUROVENT
Certified Products Guide.

HIGH EFFICIENCY VERSION


SILENCED HIGH EFFICIENCY
VERSION
COMPACT VERSION
SILENCED COMPACT VERSION

- 2 COOLING CIRCUITS
- CIRCULATION PUMP
- CIRCULATION PUMP
AND STORAGE TANK

Characteristics

Available in 9 different sizes


A
Cooling only, high efficiency
Refrigerant R410A.
E
Cooling only, high efficiency, silen2 cooling circuits
ced version
High efficiency even with partial loads
C
- Condenser unit
Heat exchangers optimised to exploit the excellent
heat transfer characteristics of the R410A
- Electronic thermostatic valve also for low
High-efficiency scroll compressors
water temperature (down to -6C)
Axial flow fans with reduced noise level
() standard mechanical thermostatic valve
Solid construction with polyester anticorrosion (Y) Mechanical thermostatic valve
painted finish
(low water temperature - down to -6C).
Operating limits with cooling mode up to
- Enlarged fans
46C
Versions with pumping assembly and tank
- Max. processed water temperature 18 C
complete with water filter, flow switch,
Versions available
expansion tank, a charging unit and antifreeze electric heater

Cooling only compact version


Microprocessor control system
L
Cooling only compact silenced version
- Control of the inlet water temperature, with

the possibility of selecting the control of the


outlet water
- Summer condensation control with 0-10V
modulating signal depending on pressure,
compensated according to the outside air
temperature (with DCPX accessory).
- Rotation of compressors and pumps according to operating hours (manual rotation
from 1400 to 1800)
- Safety capacity control
- Low pressure transducers and high pressure
trasducer (standard on all the versions)
- Automatic reset of alarms before total block
- Messages in 4 languages.
- Alarm Log

Accessories
AER485: RS-485 interface for supervision
coil from accidental knocks.
systems with MODBUS protocol.
PGS: Daily/Weekly Programmer.
AVX: Sprung anti-vibration supports. Select
Allows you to programme two time bands per
the AVX model from the compatibility table.
day (two switch on/off cycles) and to have
DCPX: This accessory allows correct operadifferentiated programming for each day of
tion with outside temperatures below 10C
the week.
and down to -10C. It is made up of an elec- RIF: Capacitor device . Connected in parallel to
tronic regulation card that varies the fan rpm
the motor winding. It allows to maintain a
on the basis of the condensation pressure,
costant COS at 0.95 and also allows an input
once the high pressure transducer is read for
current reduction (about 10%)
the purposes of keeping it sufficiently high for
It must be factory set when the unit is manuthe proper functioning of the unit. It also
factured
allows correct heating operation with outside AERWEB30: The AERWEB device allows
temperatures greater than 30C and up to
remote control of a chiller via a serial link
42C.
from a standard PC. Using additional modu DRE: Current soft starter device (about 30%
les, the device allows to control the chiller
reduction for single-circuit-units, 26% for
via the telephone network, using the AERtwo-circuit-units, 22% for three-circuit-units)
MODEM accessory; or via the GSM network,
Only available for 400V-3-phase power supusing the AERMODEMGSM accessory.
ply. It must be factory set.
AERWEB can pilot up to 9 chillers, but each
GP: Protection grille, protects the external
of these must be equipped with the AER485

or AER485P2 accessory.
DUALCHILLER: Simplified control system to
switch on and off, and command, two chillers (using Aermec GR3 command) in a single
system, as if they were a single unit.
MULTICHILLER: Control system to switch the
individual chillers on and off, and command
them, in a system in which several units are
installed in parallel, always ensuring a constant delivery to the evaporators.
TRX1: Metal cap that replaces the plastic cap,
mounted for protection in the accumulators
with holes and supplementary electric heaters.
VT: Anti-vibration support, to be fitted below
the unit base.
PRM1 e 2: FACTORY FITTED ACCESSORY. It
is a manual pressure switch electrically wired
in series with the existing automatic high
pressure switch on the compressor discharge
pipe.

Compatibility of accessories
Mod. NRL
AER485
DUALCHILLER
MULTICHILLER
PGS
AERWEB30
TRX1
AVX
VT

DCPX

DCPX M vers.
with enlarged fans
DRE
GP
TP2
RIF
PRM1/PRM2

Vers.
All
All
All
All
All
All
All
All

L
A
E

L
A
E
All
-L
A-E
All
-L
A-E
All

750

23
64
standard
64
standard
65
standard
65
standard
751
10 (x3)
10 (x3)
(x2)
53
53

800

64
standard
66
standard
65
standard
66
standard
801
10 (x3)
260
(x 2)
87
88

900

64
standard
66
standard
65
standard
66
standard
901
10 (x3)
260
(x 2)
89
90

1000

65
standard
66
standard
65
standard
66
standard
1001
10 (x4)
260
(x 2)
91
92

1250

65
standard
67
standard
65
standard
68
standard
1251
10 (x4)
350
(x 2)
91
92

1400

66
standard
67
standard
66
standard
68
standard
1401
350
350
(x 2)
93
93

1500

66
standard
67
standard
66
standard
68
standard
1501
350
350
(x 2)
94
94

1650

67
standard
68
standard
68
standard
68
standard
1651
350
500
(x 2)
94
94

1800

67
standard
68
standard
68
standard
68
standard
1801
350
500
(x 2)
94
94

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system
requirements.

Field configurator:
123
|
Code

456
|
|
|
Size

7
|
Compressor

8
9
10
11
|
|
|
|
|
Model
|
Version
|
|
Valve
Recovery units
Heat thermostat

Code:
NRL
Size:
075, 080, 090, 100, 125, 140, 150, 165, 180
Compressors:
0 - R410A standard compressors
Thermostatic valve:
- Standard mechanical thermostatic valve up to +4C
Y - Low water temperature mechanical thermostatic valve down to -6C
X - Electronic thermostatic valve also for low water temperature (down
to -6C)
Model:
- Cooling only
C - Condensing unit
Heat recovery units
- Without recovery units
D - With partial recovery (desuperheater)
T - With total heat recovery
Version:
- Compact
L - Compact, silenced version
A - High efficiency
E - High efficiency, silenced version
Batteries:
- Aluminium
R - Copper
S - Tinned copper
V - Varnished

12
|
|
|
Coils

13
|
Fan

14
15 16
|
|
|
Storage tank
|
Power supply

Fans:
- Standard
M - Enlarged
J - Inverter
Power supply:
- 400V 3~ 50Hz with thermomagnetic switches
2 - 500V 3~ 50Hz with thermomagnetic switches (contact the
company head office for versions with DCPX).
Storage tank:
00 - without storage tank
01 - low-head storage tank and single pump
02 - low-head storage tank and reserve pump
03 - high-head storage tank and single pump
04 - high-head storage tank and reserve pump
05 - storage tank (with holes for supplementary electric heaters)
low-head and single pump
06 - storage tank (with holes for supplementary electric heaters)
low-head and reserve pump
07 - storage tank (with holes for supplementary electric heaters)
high-head and single pump
08 - storage tank (with holes for supplementary electric heaters)
high-head and reserve pump
09 - double hydraulic ring
10 - double hydraulic ring with supplementary electric heater
P1 - without storage tank, with low-head pump
P2 - without storage tank, with low-head pump
and reserve pump
P3 - without storage tank, with high-head pump
P4 - without storage tank, with high-head pump
and reserve pump

Warning:
options D - T - C are not compatible with option Y
the standard options are shown by the symbol ;
Example of the commercial code: NRL090000
This is a size 090 NRL unit with standard mechanical thermostatic valve up to +4C, cooling only model, compact, with aluminium condensing coils,
standard fans, electrical panel for compressors with 400V 3~ 50Hz motors and without storage tank.

Technical data
Mod. NRL
Cooling capacity

Total power input

Water flow rate

Pressure drop

EER

ESEER

Vers. 750

190
L
174
(kW)
A
195
E
180

69
L
75
(kW)
A
62
E
68

32680
L
29930
(l/h)
A 33540
E
30960

86
L
72
(kPa)
A
88
E
75

2.75
L
2.32
(W/W)
A
3.15
E
2.65

3.87
L
3.85
(W/W)
A
4.19
E
4.05

800
211
190
218
203
78
88
69
76
36290
32680
37500
34920
66
55
66
58
2.71
2.16
3.16
2.67
4.19
4.10
4.39
4.27

900
231
210
242
224
92
101
81
88
39730
36120
41620
38530
68
57
70
61
2.51
2.08
2.99
2.55
3.97
3.95
4.27
4.20

1000
257
235
271
250
104
113
93
101
44200
40420
46610
43000
73
61
70
61
2.47
2.08
2.91
2.48
3.98
3.95
4.17
4.08

1500
375
336
399
367
161
177
142
154
64500
57790
68630
63120
79
64
61
52
2.33
1.90
2.81
2.38
3.68
3.61
4.02
3.93

1650
412
366
437
409
175
192
154
165
70860
62950
75160
70350
59
48
61
54
2.35
1.91
2.84
2.48
3.72
3.62
4.06
4.02

1800
449
393
469
436
187
208
167
179
77230
67600
80670
74990
59
46
62
54
2.40
1.89
2.81
2.44
3.79
3.59
4.02
4.02

122
113
113
109
144
144
320
320

142
153
136
145
170
173
345
348

166
177
158
169
192
195
401
404

189
200
180
192
217
217
426
426

286
308
273
292
319
325
528
534

305
328
289
306
358
365
626
633

319
348
304
324
391
398
659
666

4/2
4/2

4/2
4/2

4/2
4/2

4/2
4/2

6/2
6/2

6/2
6/2

6/2
6/2

51400
42700
49000
35300
3
3

54900
38430
72800
50960
3
4

54150
40575
71500
51805
3
4

75800
53060
70200
52650
4
4

76000
60800
102000
76500
4
6

108300
75810
125800
91110
6
8

106200
74340
122000
91500
6
8

2"1/2

3.0

3.4

3.4

3.4

4.6

4.6

5.9

5.9

5.9

5.5

5.7

5.7

5.7

8.3

8.3

8.3

10.5

10.5

6.2

5.8

5.8

5.8

7.8

7.8

10.0

10.0

10.0

11.0

9.7

81
92
71
82
201
212
191
202
700

100
120
109
122
219
241
227
237
700

9.7

9.7

14.1

14.1

14.1

17.8

17.8

92
112
95
111
211
232
213
226
700

91
111
85
104
208
229
200
216
700

111
139
103
125
256
286
247
264
700

102
133
82
108
246
279
222
246
700

88
116
106
125
220
258
226
250
700

109
134
94
111
246
271
233
245
700

99
130
82
102
237
267
221
236
700

Power supply

L
Total input current
(A)
A
E
-L
Maximum current (FLA) (A)
A-E
-L
Starting current (LRA)
(A)
A-E
Type of compressors
All
-L
Compressors (no./circuit)
A-E
Type of fans
All

L
3
Fan air flow rate
(m /h)
A
E
(no.) -L
Number of fans
A-E
Evaporator
All
Plumbing connections
All
Dimension of plumbing connections () All
Input power
(kW) All
low-head pump
Input power
(kW) All
high-head pump
Input current
(A)
All
low-head pump
Input current
(A)
All
high-head pump

Pump useful head


L
(kPa)
low-head
A
E

Pump useful head


L
(kPa)
high-head
A
E
Storage tank capacity
(l)
All

1250
1400
303
338
271
302
322
357
298
329
121
142
134
157
106
124
115
134
52120
58140
46610
51940
55380
61400
51260
56590
80
73
65
59
73
78
63
67
2.50
2.38
2.02
1.92
3.04
2.88
2.59
2.46
3.96
3.76
3.84
3.65
4.34
4.12
4.28
4.05
400V-3-50Hz (*)
208
249
226
269
196
235
211
251
261
290
267
296
529
499
535
505
Scroll
4/2
5/2
5/2
6/2
Axial
73200
77000
51240
57700
106200
104100
74340
75420
4
4
6
6
Plates
Victaulic
4
4

(*) The power supply for the 075 size is: 400V-3N-50Hz.
Performance values refer to the following conditions:
Cooling:
- water outlet temperature 7 C
- outside air temp. 35 C
- t = 5 C.

 Sound pressure measured in free field conditions, in cooling mode


at distance of 10m and direction factor = 2.
In accordance with the ISO 3744 standard
- Power supply voltage: 400 V

Mod. NRL

Vers.

L
dB(A)
A
E

L
dB(A)
A
E

 Sound power

 Sound pressure

750
85.0
80.0
85.0
77.0
53.0
48.0
53.0
45.0

800
86.0
83.0
88.0
83.0
54.0
51.0
56.0
51.0

900
86.0
83.0
88.0
83.0
54.0
51.0
56.0
51.0

1000
90.0
87.0
88.0
83.0
58.0
55.0
56.0
51.0

1250
91.0
88.0
91.0
86.0
59.0
56.0
59.0
54.0

1400
90.5
87.5
90.5
85.5
58.5
55.5
58.5
53.5

1500
90.5
87.5
90.5
85.0
58.5
55.5
58.5
53.0

1650
92.0
89.0
91.5
86.5
60.0
57.0
59.5
54.5

1800
92.0
89.0
93.5
88.5
60.0
57.0
61.5
56.5

750
196
179
201
185
70
76
62
69
2.80
2.37
3.22
2.70
144
144
320
320
123
134
110
121
85.0
80.0
85.0
77.0
53.0
48.0
53.0
45.0

800
220
198
227
211
81
91
71
78
2.71
2.19
3.19
2.71
170
173
345
348
147
158
140
149
86.0
83.0
88.0
83.0
54.0
51.0
56.0
51.0

900
241
219
252
233
95
105
83
91
2.53
2.09
3.03
2.57
192
195
401
404
172
183
163
173
86.0
83.0
88.0
83.0
54.0
51.0
56.0
51.0

1000
269
245
282
260
108
117
95
103
2.48
2.09
2.97
2.52
217
217
426
426
196
207
185
197
90.0
87.0
88.0
83.0
58.0
55.0
56.0
51.0

1250
316
283
335
311
125
139
109
118
2.52
2.03
3.08
2.64
261
267
529
535
215
234
202
216
91.0
88.0
91.0
86.0
59.0
56.0
59.0
54.0

1400
352
315
372
343
147
163
127
138
2.39
1.94
2.92
2.48
290
296
499
505
258
279
241
258
90.5
87.5
90.5
85.5
58.5
55.5
58.5
53.5

1500
391
351
415
382
166
183
145
158
2.35
1.91
2.86
2.42
319
325
528
534
297
319
281
299
90.5
87.5
90.5
85.0
58.5
55.5
58.5
53.0

1650
430
383
463
426
182
199
152
169
2.37
1.92
3.05
2.52
358
365
626
633
316
340
289
315
92.0
89.0
91.5
86.5
60.0
57.0
59.5
54.5

1800
469
410
497
454
194
216
165
184
2.42
1.90
3.02
2.47
391
398
659
666
331
361
302
333
92.0
89.0
93.5
88.5
60.0
57.0
61.5
56.5

Technical data version C


Mod. NRL C

Vers.

L
Cooling capacity
(kW)
A
E

L
Total power input
(kW)
A
E

L
EER
(W/W)
A
E
-L
Maximum current (FLA) (A)
A-E
-L
Starting current (LRA)
(A)
A-E

L
Input current
(A)
A
E

L
db(A)
 Sound power
A
E

L
db(A)
 Sound pressure
A
E

Dimensions (mm)

C
C

B
B

Height

(mm)

Width

(mm)

Depth

(mm)

Vers.
-L
A-E
-L
A-E
-L
A-E

L
A
E

750
1975
1975
1500
1500
4350
4350
1382
1382
1663
1663

800
1975
2450
1500
2200
4355
3400
1730
1740
2120
2135

The technical data in this document are not binding. Aermec S.p.A.
shall have the right to introduce at any time whatever modifications
deemed necessary for the improvement of the product.

900
1975
2450
1500
2200
4355
3400
1860
1870
2265
2280

1000
1975
2450
1500
2200
5355
3400
2015
2025
2410
2425

1250
1975
2450
1500
2200
5355
4250
2135
2145
2710
2725

Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293730
www.aermec.com

1400
2450
2450
2200
2200
4250
4250
2765
2775
2910
2925

1500
2450
2450
2200
2200
4250
4250
2960
2970
3125
3140

1650
2450
2450
2200
2200
4250
5750
3055
3065
3620
3635

1800
2450
2450
2200
2200
4250
5750
3160
3170
3735
3750

Code: SNRLLSUY.03 /1007

Mod. NRL

Weight when empty (kg)

The drawings are only examples!