Anda di halaman 1dari 64

high precision thermoregulation

Catalogue 2006
EDITORIAL
What a great day!
Many thanks! Your wanting to discover In 1990, the Tango Technology and Unis-
more about our current product range, tats began to dominate process thermal
by reading this catalogue makes this a control. Now, over fifty models allow the
great day! same thermal regulation concept to be
employed from drug discovery through
The focus of our product development scale-up, pilot plant to production. High-
is centred on process requirements for ly efficient thermal transfer capability of
thermoregulation. Our target of remai- the unique design provides the fastest
ning the leaders in environmentally-fri- ramp rates and responses to changing
endly refrigeration and thermal control thermal loads during reactions and
is reflected in the catalogue. crystallisation processes. This results in
Our early and voluntary decision to faster process times and replication of
cease using CFC and HCFC refrigerants results leading to higher yields, greater
in 1994 has been followed by our recent purity and consumption of fewer re-
decision and ability to offer refrigeration sources. Operational safety is foremost.
machines that use ZERO impact refrige- The Tango Technology‘s ability to trans-
rants (natural refrigerants). fer thermal energy makes it the safest
choice and only reliable choice to con-
Precise thermoregulation: The range, trol a fast-running exothermic reaction.
over 500 models wide, offers various Standing still is a backward step for us.
models of cooling and heating circula- Through your feedback we have further
tors. Varying cooling and heating powers developed the Tango Technology. Since
of between 0.1 kW and 130 kW with a its conception more than fifteen years
temperature range from -120°C to 400°C ago, the next generation of Unistats, for-
guarantees that we have a product that is ged in experience and driven by results
perfect for your application/process. is now available. The Tango Nuevo is
the New Dimension! You will find more
We have separated the product range information on the „Nuevo“ at the end
into three groups. of the Unistat chapter.

1. Convential bath-circulators: Last but not least, you will find a wide
the Compatible Control Range assortment of air- and water-cooled
2. Hydraulically sealed circulators: Chillers, the „Unichillers“. Unichillers
the Unistats have the task of removing process heat.
3. Chillers: the Minichillers, Unichillers Expensive mains-supplied cooling wa-
ter is replaced by mechanically-cooled,
Our convential bath-circulators are circulating water systems. The payback
named „Compatible Control“ range be- time is often only a few years and, depen-
cause of their unique electronic control- ding on operation and cost structures,
lers which can be freely exchanged bet- may sometimes be only a few months.
ween models. The simple models have Unichillers can be fitted with an optional
a pressure pump and are typically used heater for operation at higher tempera-
for the temperature control of objects tures.
in their bath. By using a pump adaptor
they become an economical solution More in-depth technical information on
for the thermoregulation of small exter- the products can be found at the back of
nally-closed systems (refractometers, the catalogue.
viscometers etc.). The more sophistica- We look forward to receiving your ques-
ted Compatible Control circulators ha- tions and further requests.
ve a high performance variable-speed
pump. When used in conjunction with ... have a great day!
an optional pressure sensor, the output
maximum pump pressure can be regula-
ted. The suffix „vpc“ (Variable Pressure
Control) identifies these models. Daniel Huber
CONTENTS
Compatible Control Thermostats
Introduction, Concept 4
Heating Bath Thermostats 7
Cooling Bath Thermostats 11
Ministat Family 14
Accessories 19

Huber Software
SpyLight 24
SpyWatch 24
SpyControl 24

Unistats with Tango Technology


Introduction, Concept 25
The Tango Technology explained 28
Unistat Range 29
Calibration Baths, Specials, Unistat Nuevo 34
Accessories 36

Unichillers
Introduction, Concept 37
Bench Top models 38
Tower Casing models 39
Unichiller ETH, Rotacool 42
Accessories 43

Specials
Hotbox 44
Beer „Force Ageing“ Thermostats 44

Accessories
Thermal Fluids 45
Adapters, Tubing 46

Quick Finder
Quick Finder Thermostats 48
Quick Finder Chillers 49

Technical Data
Technical Data 50

Glossary
Thermodynamic Terms explained 60

General
Hotline-Service 62
3-2-1 Warranty 62
Extract from Terms and Conditions 62
ompatible
ontrol Thermostat
Thermostats Plug & Play

New in Blue, „Plug and


Advances in microprocessor and display technologies
together with feedback from our customer and user
base has driven us to take our controllers to a new level
of functionality.

4 www.huber-online.com · Tel. +49-781-96030


ompatible
It‘s so easy ontrol Thermostat
Thermostats

ay
Plug & Pl
3 Years
Warranty

The controllers are microprocessor – The controllers are not an “integral”


based and have all of the features that part of the machine that they are fitted
are expected but we would like to con- to. They can be exchanged by simply
centrate on what the controllers have un-plugging the current controller and
that brings a unique dimension of flexi- plugging in a new one.
bility and functionality to your labora- The display can be customised to show
tory. as much information as the user requires
… from simply the bath temperature to
a real time “program progress” dis-
play.
Differentiating facts

Controller Options
– 3-year replacement warranty
Controller CC1 – Basic and practical
– User level and password protected New…User and Administrator levels
Administrator level. The Administrator New…Digital encoder “turn to search -
level allows the Administrator to lock- push to select”
out functions that are not required or New…48 character, 4-line LCD display
should not be accessed by the operator New…Full character user menu
Visual and audible alarms
– A uniformity of operation means that Also includes programmable alarm functions
you only need to know how to drive one Microprocessor based controller ... and more.
controller to know how to drive all three
controllers and the equipment to which Controller CC2 – External process oriented
they are fitted. All that the CC1 is furnished with plus
Process control capability, Ramping function,
– The controllers are fitted with an en- 5-step internal programmer ... and more.
coder that the user “turns to search and
pushes to select” the required menu op- Controller CC3 – Automation capable
tion. All that the CC2 is furnished with plus
10-program, 50 step internal programmer
– A full text alphabetically arranged RS232, RS485 and analogue interfaces
user menu makes the new controllers ... and more.
intuitively easier to operate.

d Play“ Technology
Interchangeable controllers through “Plug & Play” technology

www.huber-online.com · Tel. +49-781-96030 5


ompatible
ontrol Thermostat
Thermostats Concept
ay
Plug & Pl
VPC 3 Years
Pressure Warranty
Variable New!
Control atural
Option: N
nts
Refrigera

Simple, Functional,
Flexible and Robust
Temperature control with in-built flexible control options to address applications and
processes not yet thought of! The principle of Plug-and-Play technology has given our
customers the ability to swap or upgrade systems since 1980.

Because you cannot predict the future,


controllers with Plug-and-Play technolo-
refrigeration plant built in are also avai-
lable (K-series).
VPC Facts
gy enable you to adapt to it. The Huber All of the units are designed and built Thermal Insulation
“Compatible Controllers” fitted to our to conform to DIN12876 and are fitted The thermal insulation is constructed
thermostats, circulators and chillers are with “Run dry” protection and an adjus- to be vapour-tight over the life of the
fully interchangeable with each other. table independent “Over-Temperature” unit. The bath and outer surfaces are
Upgrading to more features or ease of cut-out. welded directly together. No seals or
support will never be simpler. gaskets. Everything is in one entire
VPC-Models for Higher Demands piece.
The Environment Fully Protected For more demanding applications, the
Stainless Steel Construction
All Huber refrigeration machines are “VPC“range provides more powerful
Quality, functionality and longevity.
CFC and HCFC free. We also are able to heating and cooling over a wider tem- Stainless steel is used throughout
offer refrigeration machines with natural perature range (-90…300°C) together which makes them resistive to corro-
refrigerants which have ZERO IMPACT with powerful and adjustable pumps. sion and easy to clean.
on the environment. (Pressure and suction)
Constructed from robust stainless steel, High Watts/Litre Ratio [W/L]
Plug & Play Technology the practical, functional and sturdy de- Faster response, quicker cooling, fas-
The CC1, CC2 and CC3 controllers are sign gives an unrivalled functional lon- ter heating. Compact designs and low
fully interchangeable by the user. De- gevity to these units. volume baths so that you get more of
signed for post sale flexibility and sup- Available as either heating only or hea- the power you paid for!.
port, they provide the user with varying ting/cooling units, the VPC range offers
High Power Density [W/dm³]
control options easily accessed through cooling powers up to 7 kW @ 20°C and
High cooling powers in compact ca-
an intuitive menu driven display. The heating powers up to 4 kW. The func- ses means more power for less bench
Ministat range offers this flexibility with tional design gives a further dimension space consumed. The Ministats are
the added advantage giving powerful of flexibility by allowing the use of a the shining example here!
heating and cooling from an extremely “Calibration Insert” or a “Displacement
compact design. Insert” to tune the units to specific ap- Air-Cooled or Water-Cooled or both!
plications. Standard options are for air or water
General Purpose, Low Duty Thermos- Options for the VPC-range include cooled refrigerated units. The “wl”
tats “ComBox” (to NAMUR) communication versions have both so that rejected
Starting with units designed for general system/protocol and an external pressu- heat can help warm the lab in winter
when in the air-cooled mode and in
and simple thermal control applications re sensor.
summer time, the rejected heat can be
in the temperature range of -30…200°C, All of the units are designed and built
carried away when used in the water-
the range offers options of available bath to conform to DIN12876 and are fitted cooled mode.
materials. Baths constructed from Poly- with “Run dry” protection and an adjus-
carbonate (A-series) or stainless steel table independent “Over-Temperature”
(B-series) are available. Baths with the cut-out.

6 www.huber-online.com · Tel. +49-781-96030


ompatible
Heating Thermostats ontrol Thermostat
Thermostats

Immersion Thermostats
The CC-E Immersion Thermostats are
the basis for many combinations using
polycarbonate and stainless steel baths.
In combination with a cooling both, exact
and reproducible temperatures down
to -30°C can be achieved.

CC1-E CC2-E CC3-E


Simple Versatile Interactive

Model Temperature Temperature Heating Pressure Pump Safety Dimensions Cat.No. G Price
Range Stability* Power max. Class** W x D x H / ID
[°C] [K] [kW] [l/min] [bar] [mm]

CC1-E (prev.: Polystat cc1) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0051 1
CC2-E (prev.: Polystat cc2) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0052 1
CC3-E (prev.: Polystat cc3) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0053 1
* to DIN 12876, measured in a stainless steel tank 12 litres ** FL for flammable liquids
III = adjustable overtemperature protection and addition low-liquid level protection

Bridge Thermostats
The Bridge Thermostats have a “vpc“ variable speed pressu- VPC
re-suction pump. Models with larger heating capacities are Pressure
Variable
Control
available for use with large baths. The telescopic arm can be
extended up to max. 880 mm, for use with wider baths.

Model Temperature Heating Temperature Pump Data Cat.No. G Price


Range Power Stability to max. Pressure max. Suction
[°C] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]

CC1-300B2X vpc (prev.: CC302BX-1) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0011BX 1
CC2-300B2X vpc (prev.: CC302BX-2) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0012BX 1
CC3-300B2X vpc (prev.: CC302BX-3) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0013BX 1
CC1-300B4X vpc (prev.: CC303BX-1) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0011BX 1
CC2-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0012BX 1
CC3-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0013BX 1

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 7


ompatible
ontrol Thermostat
Thermostats Heating Thermostats

Heating Bath Thermostats with Polycarbonate bath


The transparent polycarbonate baths are suitable for use up to 100°C. A CC-E Immersion Thermostat is mounted on the bath
bridge for all models. With a pump adaptor, this combination can also be used with external, closed applications. The tempe-
rature stability, in accordance with DIN 12876, is 0.02K .

ay
Plug & Pl
3 Years
Warranty

CC3-118A
CC1-111A CC3-105A
CC1-106A
CC2-107A

Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price
max. Volume Depth WxD max. WxDxH
[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]

CC1-105A (prev.: Polystat A5-1) 100 5 150 120x110 10 0,2 132x280x320 405.0001 1
CC2-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0002 1
CC3-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0003 1
CC1-106A (prev.: Polystat A6-1) 100 6 150 120x210 10 0,2 132x380x320 405.0011 1
CC2-106A (prev.: Polystat A6-2) 100 6 150 120x210 10 0,2 132x380x320 405.0012 1
CC3-106A (prev.: Polystat A6-3) 100 6 150 120x210 10 0,2 132x380x320 405.0013 1
CC1-107A (prev.: Polystat A7-1) 100 7 150 120x310 10 0,2 132x480x320 405.0021 1
CC2-107A (prev.: Polystat A7-2) 100 7 150 120x310 10 0,2 132x480x320 405.0022 1
CC3-107A (prev.: Polystat A7-3) 100 7 150 120x310 10 0,2 132x480x320 405.0023 1
CC1-111A (prev.: Polystat A11-1) 100 11 150 302x165 10 0,2 333x313x325 405.0031 1
CC2-111A (prev.: Polystat A11-2) 100 11 150 302x165 10 0,2 333x313x325 405.0032 1
CC3-111A (prev.: Polystat A11-3) 100 11 150 302x165 10 0,2 333x313x325 405.0033 1
CC1-118A (prev.: Polystat A18-1) 100 18 150 302x325 10 0,2 333x473x325 405.0041 1
CC2-118A (prev.: Polystat A18-2) 100 18 150 302x325 10 0,2 333x473x325 405.0042 1
CC3-118A (prev.: Polystat A18-3) 100 18 150 302x325 10 0,2 333x473x325 405.0043 1
CC1-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0051 1
CC2-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0052 1
CC3-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0053 1
CC1-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0061 1
CC2-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0062 1
CC3-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0063 1

8 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Heating Thermostats ontrol Thermostat
Thermostats

Heating Thermostats with Stainless steel bath


The insulated stainless steel baths are suitable for use up to 200°C. All models have a bridge-mounted CC-E Immersion Ther-
mostat. With a pump adaptor, this combination can also be used with external, closed applications. The temperature stability,
in accordance with DIN 12876, is 0.02K.

CC3-220B CC1-215B CC3-212B


CC1-208B

Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price
max. Volume Depth WxD max. WxDxH
[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]

CC1-208B (prev.: Polystat B8-1) 200 8,5 150 235x165 10 0,2 290x350x375 407.0001 1
CC2-208B (prev.: Polystat B8-2) 200 8,5 150 235x165 10 0,2 290x350x375 407.0002 1
CC3-208B (prev.: Polystat B8-3) 200 8,5 150 235x165 10 0,2 290x350x375 407.0003 1
CC1-212B (prev.: Polystat B12-1) 200 12 150 295x193 10 0,2 350x375x375 407.0011 1
CC2-212B (prev.: Polystat B12-2) 200 12 150 295x193 10 0,2 350x375x375 407.0012 1
CC3-212B (prev.: Polystat B12-3) 200 12 150 295x193 10 0,2 350x375x375 407.0013 1
CC1-215B (prev.: Polystat B15-1) 200 15 200 295x193 10 0,2 350x375x420 407.0021 1
CC2-215B (prev.: Polystat B15-2) 200 15 200 295x193 10 0,2 350x375x420 407.0022 1
CC3-215B (prev.: Polystat B15-3) 200 15 200 295x193 10 0,2 350x375x420 407.0023 1
CC1-220B (prev.: Polystat B20-1) 200 20 150 295x370 10 0,2 350x555x375 407.0031 1
CC2-220B (prev.: Polystat B20-2) 200 20 150 295x370 10 0,2 350x555x375 407.0032 1
CC3-220B (prev.: Polystat B20-3) 200 20 150 295x370 10 0,2 350x555x375 407.0033 1
CC1-225B (prev.: Polystat B25-1) 200 25 200 295x370 10 0,2 350x555x420 407.0041 1
CC2-225B (prev.: Polystat B25-2) 200 25 200 295x370 10 0,2 350x555x420 407.0042 1
CC3-225B (prev.: Polystat B25-3) 200 25 200 295x370 10 0,2 350x555x420 407.0043 1

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 9


ompatible
ontrol Thermostat
Thermostats Heating Thermostats

Heating Circulation Thermostats


Good things come in small packages! Thanks to
their low bath volumes the CC202C and CC205B are
especially suitable to control the temperature of small
external application. The temperature of small objects
can also be controlled by placing them directly in the
bath of the CC202C. Both models are available in the
variants: CC1 – simple; CC2 – comfortable; and CC3 –
communications equipped. The maximum temperature
is 200°C. The temperature stability, in accordance with CC2-202C
DIN 12876, is 0.05K. CC3-205B

Model Temperature Bath Bath Opening Heating Pressure Pump Dimensions Cat.No. G Price
Range Depth WxD Power max. WxDxH
[°C] [mm] [mm] [kW] [l/min] [bar] [mm]

CC1-202C (prev.: Polystat 201-1) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0011 1
CC2-202C (prev.: Polystat 201-2) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0012 1
CC3-202C (prev.: Polystat 201-3) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0013 1
CC1-205B (prev.: Polystat 202-1) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0011 1
CC2-205B (prev.: Polystat 202-2) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0012 1
CC3-205B (prev.: Polystat 202-3) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0013 1

Heating Bath- and Circulation thermostats VPC


Pressure
Temperatures up to 300°C- the extremely compact models have the Variable
smoothly controllable “vpc” pressure and suction pump. The pump Control
pressure can be controlled from the user-menu, using an optional pres-
sure sensor, so protecting your glassware or other delicate apparatus
CC315B vpc CC308B vpc CC304B vpc
from breakage.
405
110

130

Bath Depth: Bath Depth: Bath Depth:


CC2-315B vpc 200 mm 155 mm 145 mm
CC3-308B vpc CC1-304B vpc

Model Temperature Bath Heating Temperature Pump Data Cat.No. G Price


Range Volume Power Stability to max. Pressure max. Suction
[°C] [ltr] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]

CC1-304B vpc (prev.: CC301-1) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0001 1
CC2-304B vpc (prev.: CC301-2) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0002 1
CC3-304B vpc (prev.: CC301-3) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0003 1
CC1-308B vpc (prev.: CC302-1) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0021 1
CC2-308B vpc (prev.: CC302-2) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0022 1
CC3-308B vpc (prev.: CC302-3) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0023 1
CC1-315B vpc (prev.: CC303-1) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0011 1
CC2-315B vpc (prev.: CC303-2) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0012 1
CC3-315B vpc (prev.: CC303-3) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0013 1
* with displacement insert

10 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Cooling Thermostats ontrol Thermostat
Thermostats

Cooling Bath Thermostats


The combination of the CC-E immersion thermostat with an insulated cooling bath is the economical alternative for application
temperatures from -20°C/-30°C to 200°C. With a pump adaptor (see accessories page 22) this combination can also be used for
external, closed applications. Pump: maximum flow 10 l/min; maximum pressure 0.2 bar. The temperature stability, in accor-
dance with DIN 12876, is 0.02K. Safety classification FL, III.

ay
Plug & Pl
3 Years
Warranty
Natural
nts
Refrigera

CC2-K20
CC3-K15
CC1-K12

Model Temperature Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price
Range Volume Depth WxD 0°C -10°C -20°C WxDxH
[°C] [ltr] [mm] [mm] [mm]

CC1-K12 (prev.: Polystat K12-1) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0021 2
CC2-K12 (prev.: Polystat K12-2) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0022 2
CC3-K12 (prev.: Polystat K12-3) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0023 2
CC1-K15 (prev.: Polystat K15-1) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0031 2
CC2-K15 (prev.: Polystat K15-2) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0032 2
CC3-K15 (prev.: Polystat K15-3) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0033 2
CC1-K20 (prev.: Polystat K20-1) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0031 2
CC2-K20 (prev.: Polystat K20-2) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0032 2
CC3-K20 (prev.: Polystat K20-3) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0033 2
CC1-K25 (prev.: Polystat K25-1) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0031 2
CC2-K25 (prev.: Polystat K25-2) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0032 2
CC3-K25 (prev.: Polystat K25-3) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0033 2

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 11


ompatible
ontrol Thermostat
Thermostats Cooling Thermostats

Option:
Variostat cc – Natural
nts
The Cooling and Heating Thermo- Refrige50r...a)
(Page
stat for variable bath sizes
Unique in the world. The Variostat can control the
temperature in any bath size from -30°C to 150°C.
The single-minded construction allows the user the
greatest flexibility. The smooth, controllable “vpc”
pressure and suction pump, allows the circulation
in any bath size to be optimally controlled. Also, the
pump pressure to an external application can be pre-
cisely set and controlled, from the user-menu, using
an optional pressure.

Insulated baths made of stainless steel in three stan-


dard or custom dimensions. Fitted with a drain.

Volume End Cooling Time* [min] Free Bath Opening [mm]


Temperature with Ethanol to Position 1 Position 2
[Litre] [°C] 0°C -10°C -20°C A1 B1 C1 A2 B2 C2
5,5 -30 15 30 55 60 60 – 60 75 –
11,0 -25 30 60 110 200 200 45 200 215 30
22,0 -20 65 130 240 300 320 165 320 315 150
Position 1 Position 2 * Cooling time, measured with 2/3 of bath covered

Variostat Baths Bath Depth Bath Opening W x D Cat.No. G Price


Standard* 5,5 Litre 165 mm 228x156 mm 6052 2
11 Litre 165 mm 368x196 mm 6053 2
22 Litre 165 mm 468x316 mm 6054 2
Ball Valve M16x1 6091 1
Insulated Cover for: Cat.No. G Price
Bath 5,5 Litre 6176 2
Bath 11 Litre 6178 2
Bath 22 Litre 6180 2
* Custom sizes on request

Model Working Tem- Bath Heating Pump Data Cooling Power [kW] Dimensions Cat.No. G Price
perature Range Volume Power max. Pressure max. Suction at [°C] WxDxH
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 [mm]

variostat cc-1 -30..150 variabel 1,0 18 0,6 12 0,3 0,3 0,3 0,2 0,12 0,03 183x455x395 654.0011 2
3 controller options Temperature Stability to DIN 12876: 0,02 K

12 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Cooling Thermostats ontrol Thermostat
Thermostats

Cooling-Bath Thermostats
The K6 Models are the compact cooling and heating bath thermostats for temperatures from -25°C to 200°C. Heating capacity
2 kW. With the integrated pump adaptor, the combination of this miniature cooling bath and the CC-E immersion thermostat
can alsp be used for external, closed applications. The K6 is the economical alternative to the Ministat 125 (page 14), the smal-
lest cooling thermostat in the world. Bestseller since 1976. The small size and large capability of the Ministats, with variable
speed pump, is captivating.

Option:

Natural
nts
Refriger...a)
(Page 50

CC1-K6 CC2-K6 CC3-K6

Model Working Tem- Bath Bath Cooling Power [kW] Pressure Pump Dimensions Cat.No. G Price
perature Range Volume Depth at [°C] max. WxDxH
[°C] [ltr] [mm] 0 -10 -20 [l/min] [bar] [mm]

CC1-K6 (prev.: Polystat K6-1) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0021 2
CC2-K6 (prev.: Polystat K6-2) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0022 2
CC3-K6 (prev.: Polystat K6-3) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0023 2

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 13


ompatible
ontrol Thermostat
Thermostats Ministats

The Ministat Family


– proves that size is no guarantee of power

Pound for pound, the Ministat range is tory based calibrations (Option)
more powerful then any other thermo- – Option: ComBox (NAMUR standard)
stat in the world. Comfortable in all lo-
cations, it has proved especially useful The case and bath are pressed from the
when space is restricted such as fume same sheet of stainless steel. This elimi-
cabinets or crowded benches. nates the need for a gasket between the
bath and the frame.
Robustness: Thermal transfer from the bath to the
– The case and base of the Ministats are outer casing is prevented by an inno-
completely manufactured from stain- vative thermal control system that pre-
less steel. vents build up of condensation around
the bath opening when running cold and
Choice of controller: from heating up during high tempera-
– The controller available in 3 versions ture operation.
in the same way as the Polystat con- We have extend the original range of
trollers. (Please see “Controller op- two popular laboratory workhorses to a
tions” inset opposite). family of five. The ministat and unistat
cc have been joined by ministat 125, 230
Application flexibility: and 240.
– Air-cooled or water-cooled refrigera- Three levels of interchangeable con-
tion machine trollers offers the end-user a choice of
– There is an adjustable pump fitted. features best suited to the demands of
– User fitted “Displacement Insert” re- the application through Huber’s familiar
duces bath volume and directs power “Plug and Play” technology. This main-
to the external application (Option) tains the ability for the user to easily up-
– User fitted “Calibration Insert” im- grade controllers should the application
proves control stability to better than demand it.
0,01K (DIN 12876) allows for labora-

Model Working Tem- Bath Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price
perature Range Volume W x D / ID Power max. Pressure max. Suction at [°C]
[°C] [ltr] [mm] [kW] [l/min] [bar] [l/min] [bar] 20 0 -20

ministat 125-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0001 2
ministat 125-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0002 2
ministat 125-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0003 2
ministat 125w-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0011 2
ministat 125w-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0012 2
ministat 125w-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0013 2
ministat 230-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0001 2
ministat 230-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0002 2
ministat 230-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0003 2
ministat 230w-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0011 2
ministat 230w-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0012 2
ministat 230w-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0013 2
ministat 240-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0001 2
ministat 240-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0002 2
ministat 240-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0003 2
ministat 240w-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0011 2
ministat 240w-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0012 2
ministat 240w-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0013 2
* with displacement insert Temperature Stability to DIN 12876: 0,02 K

14 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Ministats ontrol Thermostat
Thermostats

Option:

Natural
Refriger...a)
nts VPC
Pressure
Variable
(Page 50

Control

0,8

0,6

0,4
Pressure/ bar

0,2

-0,2

-0,4

-0,6
10 20 30
Flow in l/min
Measured with water at 20˚C in accordance to DIN 12876
455 mm
400 mm
360 mm

mm

mm
mm

450

465
370

225 mm 255 mm 300 mm

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 15


ompatible
ontrol Thermostat
Thermostats Cooling Thermostats

ay
Cooling and heating thermostats to -45°C Plug & Pl
3 Years
Controller Options Warranty
VPC
Pressure
CC1: CC2: CC3:
Basic and practical External process oriented Automation capable Variable
Please see page 6 for full details.
Control

305 vpc 405 vpc/w 415 vpc/wl, 505 vpc/wl 410wl vpc

Large bath volume Circulators with small volumes especially designed for external First bath circulator in the
thermoregulation applications. Highest cooling power density and world with an air and water
largest volume cooling capacity in their class. cooled refrigeration machine.

Option:

Natural
nts
Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 200 mm Refriger...a)
(Page 50

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price
perature Range Volume Power max. Pressure max. Suction at [°C]
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 -40

CC1-305 vpc (CC130-1) -30..150 20 1,5 33 0,7 22 0,4 0,35 0,35 0,35 0,23 0,03 – 690.0011 2
CC1-405 vpc (CC241-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0011 2
CC1-405w vpc (CC241w-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0021 2
CC1-415 vpc (CC240-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0011 2
CC1-415wl vpc (CC240wl-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0021 3
CC1-410wl vpc (CC245wl-1) -45..200 22/8,5* 1,5/4,5 33 0,7 22 0,4 0,8 0,8 0,8 0,5 0,15 0,1 695.0011 3
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K

16 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Cooling Thermostats ontrol Thermostat
Thermostats

Cooling and heating thermostats to -55°C

510 vpc/w, 515w vpc 515 vpc, 905 vpc/w 520w vpc, 525w vpc,
810 vpc/w
Compact form and large cooling powers at low temperatures

Option:

Natural
nts
Refriger...a)
(Page 50
Bath Depth: 200 mm Bath Depth: 200 mm Bath Depth: 200 mm

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price
perature Range Volume Power max. Pressure max. Suction at [°C]
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40

CC1-505 vpc (CC250-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0011 2
CC1-505wl vpc (CC250wl-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0021 3
CC1-510 vpc (CC150-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,1 2,1 2,1 1,0 0,4 564.0021 2
CC1-510w vpc (CC150w-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,4 2,4 2,4 1,0 0,4 564.0031 2
CC1-515 vpc (CC155-1) -55..100 26/15* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0011 2
CC1-515w vpc (CC155w-1) -55..100 18/11* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0021 2
CC1-520w vpc (CC156w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 5,0 5,0 5,0 3,0 1,5 698.0011 3
CC1-525w vpc (CC157w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 7,0 7,0 5,0 3,0 1,5 700.0001 3
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030 17


ompatible
ontrol Thermostat
Thermostats Cooling Thermostats

Cooling and heating thermostats to -90°C

ay
Plug & Pl
3 Years
Warranty
VPC
Pressure
Variable
Control
Option:

Natural
nts
Refrigera)
(Page 50...

Pump Data VPC models

0,8

0,6

705 vpc, 805 vpc 815 vpc


0,4

Lower price alternative to the CC820 vpc for Pressure/ bar


0,2
low temperatures, when low cooling power is
adequate 0

-0,2

-0,4

-0,6
0 10 20 30
Flow in l/min
Measured with water at 20˚C in accordance to DIN 12876

0,8

0,6

0,4
Pressure/ bar

0,2

-0,2

-0,4

-0,6
0 10 20 30
Flow in l/min
Measured with water at 20˚C in accordance to DIN 12876

Bath Depth: 150 mm Bath Depth: 150 mm

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price
perature Range Volume Power max. Pressure max. Suction at [°C]
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40 -60

CC1-705 vpc (CC175-1) -75..100 5 1,5 33 0,7 22 0,4 0,25 0,25 0,25 0,2 0,15 0,1 692.0011 2
CC1-805 vpc (CC180-1) -80..100 5 1,5 33 0,7 22 0,4 0,5 0,5 0,5 0,4 0,3 0,3 693.0011 2
CC1-820 vpc (CC181-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0021 3
CC1-820w vpc (CC181w-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0031 3
CC1-815 vpc (CC185-1) -85..100 5 1,5 33 0,7 22 0,4 1,0 1,0 1,0 0,8 0,75 0,6 699.0001 3
CC1-905 vpc (CC190-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0011 3
CC1-905w vpc (CC190w-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0021 3
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K

18 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


ompatible
Accessories ontrol Thermostat
Thermostats

Flow-through Chillers
The “Flow-through Chillers” are designed for simple, low demand cooling applica-
tions. They are commonly used in combination with the CC202C or CC205B series
to remove heat in order to cool a process back to room temperature.

Model Working Cooling Power [kW] at Dimensions Cat.No. G Price


Temperature Range 0°C -10°C -20°C WxDxH
[°C] [mm]

DC30 -30..50 0,2 0,15 0,07 190x250x360 574.0002 2 Option:

DC31 -30..50 0,4 0,35 0,10 250x310x400 575.0002 2 Natural


nts
DC32 -30..50 0,6 0,47 0,12 280x340x460 652.0002 2 Refriger...a)
(Page 50

Immersion Coolers DC30

„Dip“ or „Immersion“ coolers are ideal for simple cooling applications when low Option:
temperatures are required such as vapour traps or for cooling individual flasks.
Natural
They are also commonly used to remove heat from the baths in the „A“ and nts
„B“ series. The units with an “E” have the capability to control the tempera- Refriger...a)
(Page 50
ture to a stability of +/- 0,5 K to DIN 12876. All models can be delivered with a flexible
evaporator coil (no extra cost). The model name and Cat.No. get the addition „F“.

Model Working Cooling Power [W] at Dimensions Cat.No. G Price


Temperature Range 0°C -20°C -30°C WxDxH
[°C] [mm]

TC45 -45..100 240 180 100 190x250x360 570.0008 2


TC45E -45..100 240 180 100 190x250x360 570.0009 2
TC50 -50....50 300 260 200 250x310x400 572.0006 2
TC50E -50....50 300 260 200 250x310x400 572.0007 2
TC100 -100..40 150 140 125 280x440x525 573.0007 2
TC100E -100..40 150 140 125 280x440x525 573.0008 2 TC45E
TC100E

Polycarbonate Baths
All models are designed to operate up to a maximum temperature of 100°C.

Model Bath Volume Dimensions Bath Depth Cat.No. G Price


[ltr] W x D x H [mm] [mm]
105A (prev.: A5) 5 132x280x161 150 6307 1 111A
118A
106A (prev.: A6) 6 132x380x161 150 6006 1
107A (prev.: A7) 7 132x480x161 150 6007 1
111A (prev.: A11) 11 333x313x166 150 6008 1
118A (prev.: A18) 18 333x473x166 150 6009 1

105A
106A
107A

Insulated Stainless Steel Baths


All models are designed to operate up to a max temperature of 200°C.

Model Bath Volume Dimensions Bath Dimensions Depth Cat.No. G Price


(prev.:) [ltr] W x D x H [mm] W x D x H [mm] [mm]
208B (E8) 8,5 290x350x215 235x295x150 150 6683 1
212B (E12) 12 350x375x215 295x320x150 150 6684 1
215B (E15) 15 350x375x260 295x320x200 200 6012 1
220B (E20) 20 350x555x215 295x500x150 150 6685 1
225B (E25) 25 350x555x260 295x500x200 200 6013 1

www.huber-online.com · Tel. +49-781-96030 19


ompatible
ontrol Thermostat
Thermostats Accessories

Natural Cold Baths


nts
Refrigera
Featured here are simply „cold baths“
with volumes from 12 to 25 litres.
These can be used in combination with
an immersion heater or simply run at
their lowest achievable temperature for
use as a “plunge pool”.
They are fully constructed from stainless
steel.

K20
K15 K12

Model Temperature Range Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price
Volume Depth WxD 0°C -10°C -20°C WxDxH
[°C] [ltr] [mm] [mm] [mm]

K12 -20..50(200) 12 150 295x320 0,18 0,1 350x558x215 653.0020 2


K15 -20..50(200) 15 200 295x320 0,2 0,12 350x558x240 645.0021 2
K20 -30..50(200) 20 150 295x500 0,35 0,3 0,21 350x558x370 646.0021 2
K25 -30..50(200) 25 200 295x500 0,35 0,3 0,21 350x558x420 647.0021 2

Bath Bridges
Model Cat.No. G Price

Polycarbonate bath 105A, 106A, 107A 6309 1


Polycarbonate bath 111A, 118A 6310 1
Stainless steel bath 208B 6303 1
Stainless steel bath 212B, 215B, 220B, 225B 6308 1
Refrigerated bath K12, K15, K20, K25 6311 1
Telescopic bridge for CC1-E to CC3-E extendible up to max. 640 mm 6306 1

Bath Covers for stainless steel and refrigerated baths


Model Cat.No. G Price

Bath cover 208B 6214 1


Bath cover front 212B-225B, K12-K25 6023 1
Bath cover back 220B-225B, K20-K25 6024 1
Bath cover one piece 220B-225B, K20-K25 6025 1
20 litres and larger can be in one or two parts

Adjustable Bases
Available in 3 options

Model Cat.No. G Price

Adjustable base for 118A 6328 1


Adjustable base for 111A, 212B, 215B, K12, K15 6297 1
Adjustable base for 220B, 225B, K20, K25 6298 1

20 www.huber-online.com · Tel. +49-781-96030


ompatible
Accessories ontrol Thermostat
Thermostats

Polycarbonate test tube racks


for 105A to 107A

Type Holes Immersion Depth [mm] Cat.No. G Price

A 12 x Ø22 50 6028 1
B 20 x Ø17 55 6029 1
C 20 x Ø17 95 6030 1
D 30 x Ø13 45 (Hemolyse) 6031 1
E 6 x Ø30 50 6032 1
F 36 x Ø10 25 (Eppendorf) 6033 1

Stainless Steel test tube racks


for 111A to 118A, 212B to 225B and refrigerated baths K12-K25

Type Holes Immersion Depth [mm] Cat.No. G Price

1 36 x Ø17 100 6037 1


2 45 x Ø13 70 6038 1
3 46 x Ø17 100 6039 1
4 58 x Ø13 70 6040 1

Trolleys
The trolleys make the Compatible Control Thermostats mobile.

Model Cat.No. G Price

K20, K25, CC305 vpc 6334 2


CC705 vpc, CC805 vpc, CC415 vpc, CC505 vpc 6235 2
CC410wl vpc 6295 2

Unipump (pressure booster)


Made of stainless steel for temperatures from -120 to 300°C. To compensate for
the pressure loss in external systems. The Unipump is connected in series with the
pump of the compatible control thermostat and can be controlled via the volt free
contact of the compatible control.

Unipump I max. pressure increase Cat.No. G Price


M16x1 [bar]
Unipump I 0,5 527.0001 2
Unipump I 2 stage 1,5 527.0002 2
Control Cable Unipump I / CC (3m) 6222 1

Controller
Controller Cat.No. G Price

Compatible Control Regler CC1 658.0001 1


Compatible Control Regler CC2 658.0002 1
Compatible Control Regler CC3 658.0003 1
Ministat CC1 663.0011 2
Ministat CC2 663.0012 2
Ministat CC3 663.0013 2

www.huber-online.com · Tel. +49-781-96030 21


ompatible
ontrol Thermostats Accessories

External Pt100 sensors Sensors (standard cable length 1,5 m) Cat.No. G Price

External Pt100 sensors for CC2 and CC3. Ø 6 mm 180 mm 6138 1


For external thermoregulation applicati- with handle Ø 6 mm 200 mm 6105 1
ons, a range of sensors. Custom models Ø 8 mm 400 mm 6064 1
available on request.
mounted in protective pipe Ø 8 mm 170 mm 6205 1
M16x1 sensor for flow or return 6352 1
M16x1 sensor for flow or return double 6353 1
Extension cable Pt100, 3m 6292 1

Control cables Compatible Control Cat.No. G Price


Control cables
CC RS232 / PC RS232 (3m) 6198 1
Control cables (for CC3) allow remote
CC RS485 / open (3m) 6236 1
control via the RS232, RS485 or the ana-
CC AIF / POKO open (3m) 6218 1
logue interfaces (AIF). Open ends allow
flexibility to connect as required. CC AIF / open (3m) 6320 1
CC complete / open (3m) 6319 1
Y cable PC / AIF 6651 1
15-pole plug (plug only, no cable) 6335 1

ComBox ComBox Cat.No. G Price

ComBox (NAMUR) with enhanced scope ComBox (NAMUR) Ministate, CC intern 6779 1
of functions. The ComBox communica-
tes with the CC controller via the internal
CAN bus, irrespective of whether the de-
vice is operated with a CC1, CC2 or CC3
controller.

Remote control Remote control Cat.No. G Price

for all CC thermostats with controller CC3 6734 1

Other accessories

6839

Other accessories Cat.No. G Price

6301 Holder for TC45(E)-TC100(E) evaporator to be fixed to bath bridge 6022 1


6305
Drain cock with cap 6839 1
Pump adapter for CC1-E to CC3-E, 111A to 118A, 208B to 225B, K12 to K25 6300 1
Pump adapter for 105A to 107A 6304 1
Cooling coil for CC1-E to CC3-E, 111A to 118A, 208B to 225B 6301 1
Cooling coil for 105A to 107A 6305 1
6300 Tripod bar for CC1-E, CC2-E, CC3-E 6302 1
6304 Trolley K20, K25, CC305 vpc 6334 2
Displacement insert for CC205B 6041 1

22 www.huber-online.com · Tel. +49-781-96030


ompatible
Accessories ontrol Thermostat
Thermostats

Calibration inserts tween the environment and Function principle


-10°C. A control sensor with
=5 seconds would be far too The thermostat medium at constancy
sluggish for a thermostat. We flows through the heat exchanger (A)
use sensors with approx. 1.5 and via the distributor (B) down into the
seconds. You will therefore calibrating bath. Temperature fluctua-
see a greater fluctuation on tions in the thermostat are evened out
the digital actual value dis- in (A) by overlap. The entire system acts
play than corresponds to the as a calorimeter. There are virtually no
measurement in the centre of gradients and no delay in the case of
the bath. swift ramps. Temperature stability can
be improved by a factor of 5 to 10. The
calibration baths CAL1 - CAL4 (page 33)
Calibration insert Cat.No. G Price Thermostats and the UNICAL (page 34) work with the
ministat 125 6806 2 as calibration baths same principle.
ministat 230 6807 2
ministat 240 6808 2 Thermostats are also used as
CC410wl vpc 6294 2 calibrating baths. However, if
CC505wl vpc - CC520w vpc, you wish to test temperature
CC810 vpc 6496 2 sensors using a small mass,
CC515 vpc, CC905 vpc 6150 2 for example, the following
CC308B vpc 6325 1 may occur:
CC315B vpc 6126 1 The calibrating sensor (� = 5 s)
is in the centre of the bath and Displacement inserts
shows a fluctuation of 0.01K.
The test piece A is located directly ad- Simple options to boost performance
jacent to this, the test piece B is in one
Measuring method corner of the bath and the test piece C Volume reduction inserts:
in the other corner. – reduce the liquid volume. Reducing the
The temperature constancy specified in The absolute heat capacity of the test ob- bath volume reduces the thermal load
the technical data is measured in accord- ject (the mass) is perhaps less and the and leads to faster ramping times.
ance as follows: heat transmission (surface times � value) – reduce the liquid’s exposed surface ar-
possibly greater than that of the cali- ea, which reduces moisture absorption.
The sensor of the test thermometer is brating sensor, and an unknown tempe- – contain the expansion volume HTF and
located in the centre of the bath and at rature gradient exists in the bath. In this prevent the bath from overflowing.
half the overall depth. The precondition- case each test piece will be exposed to
ing time (τ) of the sensor is 5 or 6 sec- a different temperature fluctuation, but
onds at most. Heating thermostats are the silly thing is that this fluc-
evaluated using water at a temperature tuation is not known. A stand-
of 70°C cooling thermostats using alco- ard thermostat can be a good
hol at a temperature of -10°C. calibrating bath if the volume
is large the preconditioning
Heating thermostats are operated under time of the test piece is great,
load so that a so-called typical cooling and if the temperature gradi-
water current has to flow. In cooling ent can be incorporated in the
thermostats a load of this kind is gen- testing tolerance.
erated by the pump and transmission
due to the temperature difference be- For higher demands, alumin-
ium cartridges „modelled on
a Swiss cheese“ can be used,
Displacement insert Cat.No. G Price
but the better solution for this
ministat 125 6818 2
is the calibration insert:
ministat 230 6819 2
ministat 240 6820 2
CC410wl vpc 6293 2
A
CC505wl vpc - CC520w vpc,
CC810 vpc 6049 2
CC515 vpc, CC905 vpc 6050 2
CC308B vpc 6324 1
B CC315B vpc 6043 1

www.huber-online.com · Tel. +49-781-96030 23


HUBER SOFTWARE
SpyLight

SpyLight is software for the visualisation


and documentation of process relevant
data. The communication can be via the
RS 232, RS485 or TCP/IP. The installa-ti-
on is simple. SpyLight requires very litt-
le disk space and is simple to use. The
logged data is displayed against time.
The axes can be scaled as required. The
zoom function allows easy evaluation of
short time frames.

SpyWatch
SpyWatch is based on the SpyLight soft-
ware but offers more features. Installati-
on and operation is identical. SpyWatch
can operate up to 10 channels simulta- Test run with a 20 litre reactor filled with DW Therm

neously. Each channel is independently


documented and the graphic options can
be configured as required. SpyWatch al-
lows the user to issue the following in-
structions to the unit:

– Set point
– Change from jacket to process
temperature
– Start/Stop

Spy-Funktion
for immediate Service
The spy function integrated in both pro-
grams enables simultaneous recording
of machine parameters allowing a simp-
le diagnosis in the event of a problem.
The data to be displayed can be selected
by the user. Text can be added to every
curve.
Once the curve has been generated Test run with a 300 watt in a 20 litre reactor filled with DW Therm
speed support is available. As soon as
our technicians or our service partners
receive your email with the data logging Huber Software Cat.No. G Price
the situation can be analysed, to estab- SpyLight (1 Channel) 6790 1
lish if it is a unit or application problem. SpyWatch (10 Channel) 6791 1
Renowned in its worldwide use. SpyControl (10 Channel) 6792 1
ComBox (NAMUR) Ministate, CC internal 6779 1
ComBox (NAMUR) CC400, CC401 (ext. box) 6789 1
Control cable CC/PC 6198 1
CP RS232/PC RS232 6146 1
Y cable unistat/PC + analogue 6326 1

24 www.huber-online.com · Tel. +49-781-96030


UNISTATS
Scale-Up
The Unistats cover a temperature of
-120°C to 400°C. They range in cooling
powers from 0,7 to 130 kW and heating
powers from 1,5 kW to 80 kW. A low in-
ternal volume means that this energy is
transmitted to the process (watts/litre
DIN12876). Uniformity in technology
and control throughout the range gives
each scale of application familiarity
unique to the Unistats. They are the sys-
tem of choice for kilo labs, process re-
search, mini-plants and production.
UNISTATS Plug & Play

Why the name „Tango


Technology“?
To perform the Tango dance requires
skilled partners to glide in rhythm and
unity from a tightly held and controlled
posture to another in a rapid and effort-
less movement.

The name “Tango” was adopted to re-


flect the way in which the Unistats con-
trol the temperature of a process…

…swift change, tight control, minimum


effort.

Safety First
All the Unistats are fitted with an inde-
pendent over-temperature protection
device and a circulating fluid monitor-
ing device. When these devices are acti-
vated the Unistats give a visual and au-
dible warning and shut down to stand-by
mode.

Unistats are manufactured, tested and


classified to the requirements dictated
by the strict DIN 12876.

High Temperature Cooling


HT cooling means that active cooling
for the process at temperatures up to
400°C is available. This is possible only
because of another unique Unistat fea-
ture, “HT cooling”. “HT” cooling and
mechanical refrigeration work together
to provide the widest working tempera-
ture range in a single unit. The extreme
of this is the “Unistat 420wHT” with a
temperature range that spans 420°K
from -120…300°C.

Differentiating Benefits
Tight thermal control of chemical
reactions
Rapid response to changing thermal
dynamics
No moisture absorption into the
thermal fluid at low temperatures
No oil cracking, oxidisation or dis-
colouring of thermal fluid
No oil vapours at high temperatures
A single fluid to perform high and
low temperature chemistry.
(DW-Therm has a temperature
range of -90…200°C when used with
a Unistat) Controller Cat.No. G Price
Extremely low running costs Unistat Control Panel 6139 2
Extends working temperature range Unistat Control 6107 2
of thermal fluids

26 www.huber-online.com · Tel. +49-781-96030


Facts UNISTATS
Unistats … the Concept
… passive components
and the laws of physics…
The Unistat range was first introduced
over 14-years ago. It was and remains
unique in the level of control it gives
to the user and the way in which such
massive cooling and heating powers are
not just generated, but also transferred
to your process.

The Unistat range is designed to give the


operator extremely tight control over the
temperature of a process regardless of
the varying thermal loads generated by
chemical reactions.

The low internal volume ensures that the


cooling and heating power generated by
the machine controls the temperature of
the process … not a large reservoir of
fluid. (Watts/Litre DIN 12876). This al-
lows rapid changes in temperature and
tight control over the flow of thermal
energy.

The hydraulically sealed fluid system


means no oil vapours or oil cracking at
high temperatures and no moisture ab-
sorption at low temperatures. You can
expect far longer life times and extended
temperature ranges from your expen-
sive thermal fluid with a Unistat.

However, the true engineering triumph


is in the simplicity of the design. In a
standard Unistat … from the smallest
to the largest … there is only one elec-
tro-mechanical valve. The rest is simply
physics and the laws of physics do not
break.

Standard Features
Hydraulically sealed thermal fluid
system
Low internal volume
Process control via external Pt100
Ramp function
Internal programmer
Comprehensive fault diagnostics
Continual self-test
RS232, RS485 and analogue inter-
face
Potential free and programmable
NO/NC contacts (Potential free con-
tacts)
Multifunctional programmable
alarms
Robust stainless steel construction

www.huber-online.com · Tel. +49-781-96030 27


UNISTATS Tango Principle

Tango Technology smaller the surface area the greater this ratio
becomes and the poorer the thermal transfer
2. Plate heat exchangers are used to transfer
thermal energy much more efficiently. The
and the Unistats becomes. Heat exchangers in the form of coils characteristic of a plate heat exchanger is to
have a comparatively small surface area and present a very large surface area within a very
Peter Huber realized the concept of a hy- so are poor at transferring thermal energy low volume (the sports stadium with no sides
draulically sealed, low volume thermostat effectively. as explained above!)
over 15 years ago. The development of the Imagine a sports stadium that holds 50,000 This is expressed in “watts per square cen-
first systems (and continuing improvements) people and it has only one door. Now imagine timetre” (w/cm²). Because this ratio is so low
was in partnership with close contacts in the if the stadium had open sides. 50,000 people Unistats capable of not just generating mas-
pharmaceutical industry. Following a period will be able to transfer are lot quicker through sive thermal powers but also of transferring
of Beta testing, “Tango Technology” became a larger surface area. thermal energy rapidly without damaging the
commercially available in the “Unistat” range thermal fluid.
of products in 1990. 3. Moisture absorption The net effect is a smaller, more compact and
Water condenses on cold surfaces. At the bath process directed thermostat. Results can be
Tango Technology has been refined and the opening it is seen as condensation but in the measured in increased yields, faster process
Unistats have grown to dominate their field in reservoir it condenses on the cold surface and times and duplication of results.
a variety of applications. collects on the evaporator as ice. Since ice is
The latest generation of Unistats have incre- a good insulator, the growing layer of ice pre-
ased the performance by such large margins vents heat from travelling from the thermal
with such massive leaps forward in functiona- fluid to the refrigeration system. If the heat
lity and control that we had to re-name them. cannot be removed from the thermal fluid, it
The “Nuevo” Unistats bring even faster re- cannot be removed from the process.
sponse, even tighter control and even greater
efficiencies. 4. Oil vapours
For “internal” applications such as test tu- At elevated temperatures the thermal fluids
bes or flasks that need to be partially or fully give of vapours which condense on laborato-
submersed in the reservoir, an “open-bath” ry surfaces. They can also create health and
thermostat is ideal. safety issues and clog HEPA filters. These
Open bath thermostats connected to “ex- vapours also become flammable at tempera-
ternal” applications are clumsy and slow tures dependent on the thermal fluids being
resulting in poor temperature control of the used. This limits the operational range of the
application. The large fluid volume and poor thermal fluid.
thermal transfer of the heat exchanger coils
immersed in it add up to slow ramping times Tango Technology eliminates all of the above
and lethargic response to changing thermal disadvantages.
loads such as when a heat generating reaction
takes place. The fluid circuit is hydraulically sealed, the ex-
Open-bath thermostats carry operational dis- pansion and contraction of the thermal fluid as
advantages that have a direct impact on the it heats and cools is catered for in an “expan-
process and more importantly, profits. sion tank”. This expansion tank is thermally
isolated but mechanically connected to the
The main disadvantages are: circulating fluid system.
1. The reservoir: This means that no matter what the tempera-
The reservoir serves two functions. ture is at the process, the fluid in the expansion
– To contain the thermal fluid tank remains at 2 –3 degrees around room
– To allow for the expansion of the thermal temperature.
fluid as it heats and cools Being hydraulically sealed means that there is
The larger the external application the grea- no moisture absorption at low temperatures
ter the “tidal flow” as the fluid expands and and no vapours at high temperatures. This has
contracts and so the bath has to be larger to the effect of widening the operational range of
contain it. a thermal fluid. It also means the elimination
The total thermal load that the cooling and of the build up of oily residues in the labo-
heating system must “drive” is made up ratory.
(mainly) of the total volume of thermal flu- It is important to note that this is achieved
id + the process. The larger the bath the less by using “passive” components and the laws
of the generated power will be spent on the of physics. Mechanical or electro mechanical
application. valves have not been employed for safety and
This phenomenon is expressed in “watts per efficiency reasons.
litre” (w/l). A simple example that demonst-
rates this is a kettle. A two litre kettle with a 1
kW heater will have a w/l ratio of 500 w/l and
will take “time x” to boil. The same kettle with Process control is greatly improved because:
only 1 litre of water will have a ratio of 1000w/l
and will boil in half the time. 1. There is no “reservoir” in the Unistats. The
Since the control of a reaction depends on the volume of the circulating thermal fluid is mini-
speed with which the jacket of the reactor can mal (2-4 litres in most Unistats) and so most
be adjusted to initiate and maintain the flow of the generated heating and cooling power
of thermal energy, a large volume of thermal is spent at the application.
fluid acts as effective thermal “slug” which This is expressed in watts per litre and the
adversely effects response times. Unistats have the highest ratios.
This results in extremely fast ramp times. The
2. The heat exchange surfaces temperature of the jacket can be rapidly adjus-
Thermal transfer depends greatly on surface ted to initiate and maintain the flow of thermal
area. This phenomenon is expressed as a ratio energy enabling tight control over the most
of “watts per square centimetre” (w/cm²). The dynamic of reactions.

28 www.huber-online.com · Tel. +49-781-96030


Models UNISTATS

High Temperature ay
Plug & Pl
Thermostats 3 Years
Warranty
High-precision and space-saving tem- Advantages of High Temperature
perature control up to +400°C. The new Thermostats:
HT thermostats of the Unistat cc400 Small space required
range set new standards in safety, easy Low fill-volume
operation, and rapid, dynamic tempe- High Pump capacity
rature control. The Unistat cc401w HT Rapid filling of the complete
model features integral stepper motor application efficient with venting
to control the HT-Cooling, level protec- +60°C max. expansion tank temperature
tion and configurable overtemperature Plug & Play Technology
protection. Its minimal internal volume Simple operation
allows the shortest heat-up times to be High level of safety through constant
achieved, while at the same time the monitoring
maximum expansion tank temperature
is limited to +60°C. The working life and
properties of the thermal fluid are also
protected, by avoiding direct contact
between the hot fluid and atmosphere.

The HT thermostats with controlled HT-


Cooling are suitable for temperature
control applications up to +400°C, e.g.
a double-jacketed reaction vessel (re-
actor), and pilot plants, as well as the
semiconductor Industry and high tem-
perature distillation. They are suitable to
maintain a high constant temperature,
or to contain an exothermic reaction at
high temperature.

Unistats to 400°C unistat cc400 unistat cc401w HT-3

Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]
unistat cc400-3 75..400 12 0,5 3,0 190x240x635 400.0003 3
unistat cc401-3 50..400 23 0,5 3,0/9,0 285x330x735 400.0023 3
unistat cc401w HT-3 (15) 50..400 23 0,5 3,0/9,0 10,0 10,0 10,0 10,0 285x330x735 400.0033 3

Unistate to 300°C
Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]
unistat T326 (15) 65..300 15 0,5 3,0/6,0 425x220x635 532.0002 3
unistat T326 HT 65..300* 15 0,5 3,0/6,0 3,2 2,3 0,6 425x220x635 531.0002 3
unistat T326w HT (15) 65..300 15 0,5 3,0/6,0 10,0 10,0 6,0 425x220x635 530.0002 3
unistat T327 (15) 65..300 70 1,6 12,0 460x550x1336 525.0002 3
unistat T327w HT (15) 65..300 60 1,6 12,0 10,0 10,0 6,0 460x550x1336 526.0002 3
* The lowest temperature is 15 K above room temperature

Accessories see page 36, 45.. www.huber-online.com · Tel. +49-781-96030 29


UNISTATS Models

ay
Plug & Pl
3 Years New!
Warranty Ex Zone
It takes two to tango! Solutions

Thermodynamics and Microelectronics.


Hydrauli-cally sealed, no fumes, no oil
cracking, no moisture absorption, sealed
expansion vessel for open baths. Tango
and Unistat 360 can be located under the
lab bench and the control panel (Plug &
Play) can be located in the work place
via the adapter cable. These units in-
corporate the full range of the vapour
compression technology: single and
multiple stage compression, cascade, air
and water-cooling. Temperature stability
better than 0,05 K to DIN 12876. Ideal for
scale-up from lab to production. Tango

636 mm
and the big-power Unistats are the lead-
ing technology of thermostats. Please
ask the Tango Club.

High Technology „CoolNet“


All Unistat refrigeration machines use the
stepper motor control expansion valve
„CoolNet“, manufactured by Huber. This
ensures that optimal performance from the
evaporator is achieved, and the maximum
possible power is obtained. Without the
CoolNet the Unistats could not achieve such
dynamic, performance, control stability and
operational safety.

mm
270
425 mm
New! Ex Zone Solutions
There are two solutions for Ex Zone
thermoregulation applications. The first
is to work with a standard unit located
in a safe area and an Ex Rated remote
control panel located in the hazardous
zone. The second solution is to locate
a fully Ex Rated unit (pressure encap-
sulation, see table below) within the
hazardous zone. Further information is
available on request.

Model Cat.No. G Price

EEx p Housing I (for Unistats T327w, 140w, 141w, 150w, 151w, 380w, 385w, 386w, 390w, 420w, 160w, 161w, 162w, 163w) 6967 –
EEx p Housing II (for Unistats 164w, 165w, 290w, 291w and UC160Tw-4) 6968 –
EEx p Housing III (for Unistats 167w, 169w) 6969 –
EEx p Housing IV (for Unistats T326w HT, tango, 340w, 360w) 6970 –
Remote Control Unistat EXi - EEx ib IIC T4 6702 –
EXi Temperature Measurement (Pt100 converter) 6703 –

30 www.huber-online.com · Tel. +49-781-96030 Accessories see page 36, 45..


Models New! UNISTATS
Ex Zone Option:

Natural
Unistats to -55°C Solutions Refriger...a)
nts
(Page 50

Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 W x D x H [mm]
unistat tango -40..200 15 0,5 1,5/3,0 0,7 0,7 0,7 0,4 0,05 425x270x636 534.0003 3
unistat tango HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,3 0,7 0,4 0,05 425x270x636 533.0003 3
unistat 340 -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x300x636 710.0004 3
unistat 340w -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x270x636 710.0003 3
unistat 340 HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0003 3
unistat 340w HT -40..300 15 0,5 1,5/3.0 3,5 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0004 3
unistat 140 -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 544.0004 3
unistat 140w -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 545.0004 3
unistat 140w-FB -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 920x635x740 545.0004FB 3
unistat 140 HT -40..300 60 1,6 2,0 3,2 2,3 2,7 2,5 1,8 0,2 460x550x1336 712.0001 3
unistat 140w HT -40..300 60 1,6 2,0 3,5 3,0 2,7 2,5 1,8 0,2 460x550x1336 712.0002 3
unistat 141 -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,3 460x550x1336 550.0005 3
unistat 141w -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,2 460x550x1336 551.0005 3
unistat 141w-FB -40..200 70 1,6 4,0 3,0 3,5 3,5 2,2 0,2 920x635x740 551.0005FB 3
unistat 141 HT -40..300 60 1,6 4,0 3,2 4,0 3,5 3,5 2,2 0,3 460x550x1336 713.0003 3
unistat 141w HT -40..300 60 1,6 4,0 3,5 4,0 3,5 3,5 2,2 0,2 460x550x1336 713.0004 3
unistat 150w -50..200 100 1,5 6,0 5,0 5,0 5,0 2,8 0,9 460x550x1336 715.0001 3
unistat 150w HT -50..300 80 1,5 6,0 3,5 6,0 5,5 5,0 2,8 0,9 460x550x1336 716.0001 3
unistat 151w -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 540x600x1336 717.0001 3
unistat 151w-FB -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 920x635x740 717.0001FB 3

Unistats to -60°C
Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
Range [°C] [l/min] [bar] [kW] 200 100 0 -20 -40 -60 W x D x H [mm]
unistat 160w -60..200 50 1,5 6,0 7,0 7,0 7,0 6,0 3,3 0,8 600x700x1515 552.0005 4
unistat 161w -60..200 50 1,5 12,0 9,0 9,0 9,0 7,0 4,8 1,0 600x700x1515 556.0005 4
unistat 162w -60..200 90 2,5 12,0 12,0 12,0 12,0 12,0 7,0 2,0 700x800x1515 557.0005 4
unistat 163w -60..200 90 2,5 12,0 16,0 16,0 16,0 13,5 8,4 2,2 700x800x1515 559.0004 4
unistat 164w -60..200 110 2,5 24,0 22,0 22,0 20,0 18,0 15,0 5,0 920x1000x1655 719.0001 5
unistat 165w -60..200 110 2,5 24,0 26,0 26,0 25,0 24,0 18,0 6,0 920x1000x1655 720.0001 5
unistat 166w -60..200 100 2,5 30,0 30,0 30,0 30,0 30,0 20,0 6,0 920x1200x1655 723.0001 5
unistat 167w -60..200 100 2,5 36,0 40,0 40,0 40,0 40,0 22,0 7,0 1800x1200x1830 724.0001 5
unistat 169w -60..200 100 2,5 48,0 65,0 65,0 65,0 65,0 38,0 11,0 1800x1200x1830 726.0001 5
unistat 1060w -60..200 100 2,5 96,0 130,0 130,0 130,0 80,0 60,0 20,0 4500x2000x2000 733.0001 5

Unistat Minus
The „Unistat Minus“ models had been specially developed for work at
low temperatures. These low cost alternatives have powerful refrige-
ration and „Tango“ technology with the user friendly controller CC3.
They are available either in flat design (FB) or in a tower casing. Typical
applications are pour point apparatus, low temperature calorimetry,
combination chemistry or crystallisations.

unistat minus 55w-FB-3

Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
Range [°C] [l/min] [bar] [kW] 0 -20 -40 -60 -80 W x D x H [mm]
unistat minus 55w-FB-3 -55..50 55 1,6 2,0 6,0 4,2 1,5 920x635x740 717.0106 4
unistat minus 85w-FB-3 -85..50 18 0,7 2,0 2,3 2,3 2,0 1,2 0,2 1200x650x745 549.0105 4
unistat minus 90w-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 600x700x1550 554.0112 4
unistat minus 90w-FB-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 1500x700x900 554.0109 4

Accessories see page 36, 45.. www.huber-online.com · Tel. +49-781-96030 31


UNISTATS Models

Option:

Natural Model variations


nts
Refrige50r...a)
w: water-cooled refrigeration
(Page HT: with high temperature cooler
FB: flat built version

New!
Ex Zone
Solutions

unistat 360 unistat 385 unistat 385w-FB

Unistats to -85°C
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]
unistat 360 -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0006 3
unistat 360w -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0005 3
unistat 360 HT -75..300 16 0,8 1,5/3,0 3,2 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0006 3
unistat 360w HT -75..300 16 0,8 1,5/3,0 3,5 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0005 3
unistat 380 -80..200 35 0,8 2,0 1,3 1,3 1,3 1,3 0,9 0,2 460x600x1346 539.0006 3
unistat 380w -80..200 35 0,8 2,0 1,5 1,5 1,5 1,5 0,9 0,2 460x600x1346 540.0006 3
unistat 380 HT -80..300 30 0,8 2,0 3,2 2,3 1,8 1,3 1,3 1,3 0,9 0,2 460x600x1346 537.0006 3
unistat 380w HT -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 460x600x1346 538.0006 3
unistat 380w HT-FB -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 1200x650x740 538.0006FB 3
unistat 385 -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 548.0006 4
unistat 385w -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 549.0006 4
unistat 385w-FB -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 1200x650x740 549.0005FB 4
unistat 385 HT -85..300 30 0,8 3,0 3,2 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 546.0006 4
unistat 385w HT -85..300 30 0,8 3,0 3,5 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 547.0006 4
unistat 386 -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 721.0002 4
unistat 386w -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 722.0002 4

Unistats to -90°C
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]
unistat 390w -90..200 40 1,5 6,0 5,2 5,2 5,0 4,2 3,1 0,9 600x700x1560 554.0005 4
unistat 390w HT -90..300 35 1,5 6,0 4,5 2,6 7,0 5,2 5,0 4,2 3,1 0,9 600x700x1560 553.0005 4
unistat 290w -90..200 57 1,3 12,0 16,0 16,0 16,0 16,0 15,0 13,5 3,5 920x1200x1655 558.0003 4
unistat 291w -90..200 80 2,5 24,0 19,0 19,0 19,0 19,0 17,0 15,0 6,0 920x1200x1655 705.0001 5
unistat 292 -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 1700x3500x1850 706.0001 5
unistat 292w -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 2400x1200x1750 706.0002 5

32 www.huber-online.com · Tel. +49-781-96030 Accessories see page 36, 45..


Models UNISTATS

New!
Ex Zone
Solutions

unistat 390w unistat 291w

Unistats to -120°C
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -60 -80 -100 W x D x H [mm]
unistat 420w -120..100 18 0,7 2,0 1,5 1,5 1,5 1,4 1,3 1,0 700x800x1515 543.0004 4
unistat 420w HT -120..300 16 0,7 2,0 3,5 3,2 3,0 1,5 1,5 1,4 1,3 1,0 700x800x1515 541.0004 4
unistat 421w -120..100 44 1,5 4,0 2,5 2,5 2,5 2,5 2,0 2,0 920x1200x1655 707.0001 5

Calibration Baths
Option:
This range of calibration baths are de-
Natural
nts
Refriger...a)
signed for physically small devices.
(Page 50
– Stability better than 0,02 K
to DIN 12876
– Temperature range: -80…250°C
– Bath depth 400 mm

Model Working Temperature Bath Bath Heating Power Cooling Power [kW] Dimensions Cat.No. G Price
Range Volume [kW] at 0°C WxDxH
[°C] [mm] [ltr] [mm]

CAL1 -20..150 Ø120 x 400 7 1,0 0,3 585x425x550 665.0004 3


CAL2 -40..200 Ø120 x 400 7 1,5 0,5 585x425x550 665.0005 3
CAL3 -80..150 Ø120 x 400 7 1,5 0,3 585x560x550 665.0003 3
CAL4 +25..250 Ø120 x 400 7 1,5 – 585x355x550 665.0006 3
All measurements valid for an ambient temperature of +20°C

Accessories see page 36, 45.. www.huber-online.com · Tel. +49-781-96030 33


UNISTATS Specials

UNICAL

Calibration systems

The “Unicals” are range of calibration


baths that are designed to be powered
by the Unistat range.

In this way it is possible to manufacture


very large calibration baths capable of
carrying out calibrations from very low
temperatures to very high temperatures.

– Stability better than 0,02 K


to DIN 12876
– Temperature range: -80…250°C
– Very large bath volumes available
for batch calibrations
– Can be customised to suit application

The range of calibration baths grows Model Volume Bath Opening Volts at Dimensions Cat.No. G Price
continually: Large, round (overflow in [ltr] [mm] 50 Hz W x D x H [mm]
the middle) open baths or rectangular UniCAL 1 7 Ø115 x 400 230V 708x365x550 655.0001 3
form combined with quick and precise UniCAL 2 32 Ø500 x 215 230V Ø700x490 655.0002 3
Unistats. Temperature Range: -100 to UniCAL 3 23 298 x 395 x 200 230V 520x620x505 655.0003 3
300°C. Custom models available

Cover Temperature Range Dimensions Cat.No. G Price Holes Price


Material [°C] D x H [mm] [mm]
Edelstahl -100...+300 Ø 220 x 65 6367 1 Ø4-Ø10
Teflon -100...+200 Ø 220 x 30 6365 1 Ø4-Ø10
Polyethylen -100...+100 Ø 220 x 30 6366 1 Ø4-Ø10
Custom models available

Custom Model:
UniCAL 8 with Unistat 161w Insulated Stainless Steel Cover

34 www.huber-online.com · Tel. +49-781-96030 Accessories see page 36, 45..


UNISTAT NUEVO
The New Dimension
Touchscreen TFT-Display
Simple to operate
Variable Pressure Control VPC
Non-linear programmable ramping
True Adaptive Control (TAC)
Bench top models -75 ... +250°C
Plug & Play Technology
Natural Refrigerants (Option)

True Adaptive Control


(Selectable
Effect system
of True response)Control
Adaptive

Rapid ramping (no overshoot) Faster ramping (minimal overshoot)


Temperature

Temperature

Setpoint Setpoint
with TAC with TAC
without TAC without TAC

Models and further information available at www.huber-online.com Time Time

The proven Unistat Technology (Page 28): The The new dimension: Air-cooled or air AND wa- Easy to operate, it features an internal program-
Unistat Tango Nuevo is a hydraulically sealed ter-cooled refrigeration system (introduced by mer, process control capability and an organi-
circulator with a fully self contained expansion Huber in 1997) with an environmental option cally adaptive, self tuning PID controller. The
tank at atmospheric pressure. This means that using natural refrigerants. Active mechanical advanced controller learns and adapts to chan-
the thermostat is atmospherically sealed and cooling from -45 up to +250°C. Stronger pump ging application demands … constantly. Acces-
can be located below or above the level of the with soft start to eliminate pressure surges is sories include: PC software for documentation
application without the risk of siphoning or fitted. The flow pressure is monitored and fully of process relevant data, diagnostics and PC-
back-flow even during power-down or when in controlled by VPC technology. The Unistat Pilot based control: SpyLight, SpyWatch, SpyCont-
stand-by status. features a colour TFT display with touch-screen. rol.

www.huber-online.com · Tel. +49-781-96030 35


UNISTATS Accessories

Connections for Mettler Adaptor Quantity Cat.No. G Price

Toledo ‚LabMax‘ and ‚RC1‘ unistat 14x Metal Hose NW20/ M30x1,5:
For use with the LabMax or the RC1 in M30x1,5 AG - 1/2“ female 2x 6394 1
variations High temp, Mid temp and low M30x1,5 AG - 3/4“ female 2x 6442 1
M30x1,5 AG - M16x1 female 2x 6431 1
temp, use the adapters listed here.

External Pt100 sensors Sensors (standard cable length 1,5 m) Cat.No. G Price

For external thermoregulation applica- Ø 6 mm 180 mm 6138 1


tions there are different sensors avai- with handle Ø 6 mm 200 mm 6105 1
lable. Special versions can be made on Ø 8 mm 400 mm 6064 1
request. mounted in protective pipe Ø 8 mm 170 mm 6205 1
M16x1 sensor for flow or return 6352 1
M16x1 sensor for flow or return double 6353 1
M30x1,5 sensor for flow or return 6509 1
M30x1,5 sensor for flow or return double 6363 1
Extension cable Pt100, 3m 6292 1

Control Cables Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price
from to Note
Control cable for use with RS232, RS485
CP PC RS232 6146 1
or analogue interface (AIF). Control ca-
CP Unistat controller Extension cable for control panel 6147 1
bles can be configured to request.
CP RS485 Cable end open 6279 1
CP Analog Cable end open 6254 1
CP Remote control CC3 6737 1
Y cable unistat/PC + analogue 6326 1

Pressure booster pump


Pressure pump of stainless steel for tem-
Unipump Pump max. Dimensions Cat.No. G Price
peratures from -120 to 300°C. To compen- [l/min] [bar] W x D x H [mm]
sate for the pressure loss in external sys- Unipump I M16x1 23 0,5 170x380x175 527.0001 2
tems. The Unipump is connected in series Unipump I 2 stage M16x1 35 1,5 170x380x175 527.0002 2
with the pump of the unistat and can be Unipump II M30x1,5 70 1,5 205x430x290 527.0003 2
controlled via the volt free contacts of the Unipump II 2 stage M30x1,5 70 2,5 205x430x290 527.0004 2
unistat control. Control cable Unipump / unistat (3m) 6221 1

Bypass Bypass Cat.No. G Price

For systems with high pressure loss. The Unistat, bench top M16x1 6415 1
Bypass is connected between the flow Unistat, others (non-bench top) M16x1 6416 1
and return and is manually controlled Unistat M30x1,5 6417 1
(stepless). Unistat 420w M16x1 6418 1

Safety Devices Safety Devices Cat.No. G Price


Float switch in-sight glass, leak moni-
toring (highest safety class). Float Switch 6152 1
Atmospheric sealing kit for sight glass Sealing Kit 6523 2
and expansion vessel, e.g. for inert gas
blanketing.

Trolleys Model Cat.No. G Price


The trolleys make the Unistats mobile.
unistat tango, unistat tango HT, 340w 6280 2
unistat T326 6469 2
unistat 360, 360w, 360 HT, 360w HT 6263 2
unistat 340, 340 HT, 340w HT 6630 2

36 www.huber-online.com · Tel. +49-781-96030


Facts UNICHILLERS

Differentiating Features
 Simple to use

 Robustly reliable and innovative refrigeration


system

 Bright LED level display…can easily be read


from long distances

 Powerful pumps for demanding applications

 Frame and casing manufactured from


stainless steel

 Industrial strength resists work-place abuse

 Efficient energy management lowers resource


consumption
Controller Cat.No. G Price
CC1 658.0001 1  Tower design consumes less floor space
CC2 658.0002 1
CC3 658.0003 1  CC1, CC2 and CC3 controllers for operational
Unistat Control Panel 6139 2 uniformity
Unistat Control 6107 2
 Water-cooled and air-cooled versions available

 Lifting lugs fitted to aid location


UNICHILLER Bench Top

Features
Operation Programmer Mains Failure Programmable
Simple menu driven control cc2 up to 5 steps Option to switch the thermostat off
cc3 50 steps divisible in in the event of mains failure or auto
LCD for good view 10 programs restart on reinstatement of electrical
LCD for set point/actual tempera- from 10 kW: supply.
ture, operating conditions, set 9 programs with 30 steps
point limits, service information Fault Diagnosis
Self Diagnostic Flow-control
Dialogue Automatically after switch on Over- and undertemperature control
digital interface RS232, RS485, overheating protection
analogue interface 4 - 20 mA for units from 10 kW on remote
Multifunctional Alarm
(not CC1 and CC2)
visual and audio, adjustable alarm maintenance via modem
values volt free contact program- constant memory for the logging
Cascade Control
mable (not cc1 and cc2) of the unit’s state
Connection for external
Pt100 sensor (not CC1)
Calibrateable Autostart
Software Internal and external Pt100 sensor Date/time and after mains failure
Windows-software for documen- calibrated through offset correction. (from 10 kW)
tation and visualization. Free Soft-
ware updates are guaranteed!

New Minichillers Unichiller (bench top)


The minichiller is an incredibly com- Unichillers are intelligent circulation
pact chiller that packs a cooling punch coolers in the low-priced, classic desk-
beyond its size. Compact, robust and top housing.
powerful, now in stain- Typical is the flat construction with a
less steel casing. The- footprint which orientates itself by the
re are four controller depth of the desk. The more powerful
options, the simplest models beginning from UC015 fit under
option does not offer the working bench. All Unichillers work
the unique advantages with the interchangeable CC controllers.
of Plug & Play techno- With the help of a remote kit the control-
logy. The CC1 to CC3 ler can be separated from the Unichiller.
options with the supe- All Unichillers have an automatic pow- UC015-3
rior funtionality do ha- er adjustment and can be factory-fitted
Option:
ve these benefits. The with a heating.
cooling performance Natural
nts
is the same irrespec- Refriger...a)
(Page 50
tive of the controller. UC006A-2

Model Working Temperature Pump max. Cooling Power [kW] at [°C] Dimensions mobile Cat.No. G Price
Range [°C] [l/min] [bar] 15 0 -10 W x D x H [mm] with roller
minichiller -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0010 2
minichiller w -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0020 2
minichiller-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0011 2
minichiller w-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0021 2
UC006A-1* -20...40 18 0,5 0,6 0,5 0,22 277x500x425 – 576.0031 3
UC007 -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0050 3
UC007-1* -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0051 3
UC015-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0021 3
UC015w-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0031 3
UC022-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0031 3
UC022w-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0041 3
UC020-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0031 3
UC020w-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0041 3
UC025-1* -10...40 25 3,0 2,5 2,0 1,2 460x615x755 incl. 674.0041 3
UC025w-1* -10...40 25 3,0 2,5 2,0 1,2 460x510x755 incl. 674.0051 3
* 3 controller options Option heating for minichiller-x 1 kW, for UC models 2 kW

38 www.huber-online.com · Tel. +49-781-96030 Accessories see page 43, 45..


Plug & Play UNICHILLERS
ay
Plug & Pl
3 Years
Warranty

UC006Tw-3

New Look:
Unichiller in
Tower Casings
Controller Options

Unichillers. Controller CC1 – Basic and practical


New…User and Administrator levels

0,6 kW…100 kW @ 15°C New…Digital encoder “turn to search -


push to select”
New…48 character, 4-line LCD display
New…Full character user menu
Visual and audible alarms
The smaller Unichillers con- laboratory floor space. Also includes programmable alarm functions
sume minimum floor space New: to save power and re- Microprocessor based controller ... and more.
with the new tower construc- duce noise, the chillers are
Controller CC2 – External process oriented
tion. fitted with condensor fans
All that the CC1 is furnished with plus
High cooling powers are that vary their speed accor- Process control capability, Ramping function,
matched with low volume ding to the load conditions. 5-step internal programmer ... and more.
(to DIN 12876) in typical Familiar HUBER flexibility is
Controller CC3 – Automation capable
HUBER style so that high brought via the “CC” choice
All that the CC2 is furnished with plus
cooling powers does not of interchangeable/upgrade- 10-program, 50 step internal programmer
mean sacrificing valuable able controllers. RS232, RS485 and analogue interfaces
... and more.

www.huber-online.com · Tel. +49-781-96030 39


UNICHILLERS in Tower Casings

Unichillers (air cooled bench models)


Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C
UC006T-1* -25..40 A 30 0,7 0,6 0,45 0,25 0,07 350x310x615 9,0 6,7 582.0011 3
UC009T-1* -25..40 A 30 0,7 0,9 0,7 0,48 0,25 350x310x615 13,5 10,5 584.0011 3
UC012T-1* -25..40 A 30 0,7 1,2 1,0 0,7 0,4 350x310x615 18,0 15,0 586.0011 3
* 3 controller options Option heating 2 kW to 100°C

Controller Options

CC1: CC2: CC3:


Basic and practical External process oriented Automation capable

Please see page 37 for full details.

Option:

Natural
nts
Refrige50r...a)
(Page

UC012T-1 UC016T-3 UC055T-2

Unichillers (air cooled)


Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C
UC016T-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 450x510x1160 6,4 3,4 587.0011 3
UC020T-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 450x510x1160 7,5 7,5 588.0011 3
UC025T-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 450x510x1160 9,4 4,5 589.0011 3
UC040T-1* -10..40 B 22 3,0 4,0 2,2 1,0 - 500x550x1265 11,5 6,3 590.0011 3
UC045T-1* -20..40 B 22 3,0 4,5 4,3 2,9 1,5 500x550x1265 12,9 12,4 591.0011 3
UC055T-1* -10..40 C3 65 4,0 5,5 3,0 1,3 - 600x630x1570 9,3 5,1 592.0011 3
UC060T-1* -20..40 C3 65 4,0 6,0 6,0 3,9 1,5 600x630x1570 10,1 10,1 593.0011 3
UC080T-1* -10..40 C3 65 4,0 8,0 4,8 2,5 - 600x730x1570 11,6 7,0 594.0011 3
UC100T-4 -20..40 C3 65 4,0 10,0 10,0 6,5 2,5 600x790x1570 13,4 13,4 595.0006 4
UC110T-4 -10..40 C3 65 4,0 11,0 6,0 2,7 - 600x790x1570 14,8 8,1 596.0006 4
UC130T-4** -10..40 C3 65 4,0 13,0 7,2 3,2 - 874x1185x1870 6,7 3,7 597.0006 4
UC150T-4** -20..40 D3 140 4,0 15,0 15,0 9,7 3,7 874x1485x1870 6,2 6,2 598.0005 4
UC160T-4** -10..40 D3 140 4,0 16,0 8,8 4,0 - 874x1185x1870 8,3 4,5 600.0005 4
UC200T-4** -10..40 D3 140 4,0 20,0 11,0 5,0 - 874x1485x1870 8,2 4,5 601.0005 4
UC210T-4** -20..40 D3 140 4,0 21,0 21,0 13,6 5,2 874x1985x1870 6,5 6,5 602.0005 4
UC250T-4** -10..40 D3 140 4,0 25,0 14,0 6,2 - 874x1985x1870 7,7 4,3 603.0005 5
UC260T-4** -20..40 D3 140 4,0 26,0 26,0 13,6 5,2 874x1985x1870 8,0 8,0 604.0005 5
UC300T-4** -10..40 D3 140 4,0 30,0 16,5 7,5 - 874x1985x1870 9,2 5,1 605.0005 5
UC400T-4** -10..40 D3 140 4,0 40,0 22,0 10,0 - 2500x1685x1800 5,3 2,9 650.0005 5
* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly

40 www.huber-online.com · Tel. +49-781-96030 Accessories see page 43, 45..


in Tower Casings UNICHILLERS
Unichillers (water cooled bench models)
Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C
UC006Tw-1* -20..40 A 30 0,7 0,6 0,45 0,4 0,25 230x280x550 16,9 12,7 606.0031 3
UC009Tw-1* -25..40 A 30 0,7 0,9 0,7 0,4 0,2 230x280x550 25,4 22,6 607.0031 3
UC012Tw-1* -25..40 A 30 0,7 1,2 1,0 0,6 0,3 350x310x615 18,0 15,0 611.0011 3
UC015Tw-1* -25..40 A 30 0,7 1,5 1,2 0,8 0,4 350x310x615 22,5 18,0 613.0011 3
UC023Tw-1* -25..40 A 30 0,7 2,3 1,6 0,9 0,5 350x310x615 34,5 24,0 615.0011 3
* 3 controller options Option heating 2 kW to 100°C, except UC006Tw and UC009Tw

Heating Option
All models (except UC006Tw and UC009Tw)
can be factory-fitted with a heating. The tem-
perature range is extended to +100°C. Please
ask for the additional price for the heating.
The model name and Order No. get the addi-
tion “H”. Increased heating powers available
on request.

Option:

Natural
nts
Refriger...a)
(Page 50

UC006Tw-3 UC012Tw-3 UC055Tw-1 UC100Tw-4

Unichillers (water cooled)


Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C
UC016Tw-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 400x440x1100 8,8 4,6 616.0011 3
UC020Tw-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 400x440x1100 10,3 10,3 617.0011 3
UC025Tw-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 400x440x1100 12,9 6,2 618.0011 3
UC030Tw-1* -20..40 B 22 3,0 3,0 3,0 2,0 1,0 400x440x1100 15,5 15,5 619.0011 3
UC040Tw-1* -10..40 B 22 3,0 4,0 2,1 0,95 - 400x440x1100 20,7 10,8 620.0011 3
UC055Tw-1* -10..40 C3 65 4,0 5,5 4,0 2,0 - 500x550x1265 15,8 11,5 621.0011 3
UC060Tw-1* -20..40 C3 65 4,0 6,0 6,0 3,8 1,4 500x550x1265 17,2 17,2 622.0011 3
UC080Tw-1* -10..40 C3 65 4,0 8,0 4,65 2,35 - 500x550x1265 23,0 13,4 623.0011 3
UC100Tw-4 -20..40 C3 65 4,0 10,0 10,0 6,3 3,0 600x600x1450 19,2 19,2 624.0005 4
UC110Tw-4 -10..40 C3 65 4,0 11,0 5,8 2,55 - 600x600x1450 21,1 11,1 625.0005 4
UC130Tw-4 -10..40 C3 65 4,0 13,0 7,0 3,0 - 600x600x1450 24,9 13,4 626.0005 4
UC150Tw-4 -20..40 D3 140 4,0 15,0 15,0 10,0 5,0 760x800x1560 15,8 15,8 627.0005 4
UC160Tw-4 -10..40 D3 140 4,0 16,0 9,5 5,5 - 600x600x1450 30,7 18,2 628.0005 4
UC200Tw-4 -10..40 D3 140 4,0 20,0 10,7 4,7 - 760x800x1560 21,1 11,3 629.0005 4
UC210Tw-4 -20..40 D3 140 4,0 21,0 21,0 16,5 10,0 760x800x1560 22,1 22,1 630.0007 4
UC250Tw-4 -10..40 D3 140 4,0 25,0 13,6 5,8 - 760x800x1560 26,4 14,3 631.0005 5
UC260Tw-4 -20..40 D3 140 4,0 26,0 26,0 20,0 12,0 760x800x1560 27,4 27,4 632.0005 5
UC300Tw-4** -10..40 D3 140 4,0 30,0 16,0 7,1 - 760x800x1560 31,6 16,9 633.0005 5
UC400Tw-4** -10..40 D3 140 4,0 40,0 21,0 10,0 - 1000x920x1665 26,1 13,7 634.0005 5
UC500Tw-4** -10..40 D3 140 4,0 50,0 26,0 - - 1000x920x1665 32,6 17,0 635.0005 5
* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly

Accessories see page 43, 45.. www.huber-online.com · Tel. +49-781-96030 41


UNICHILLERS Specials
Option:

Natural
nts
Refriger...a)
Unichiller ETH (Page 50

Unichillers are intelligent circulation The unit will automatically switch to wa-
coolers which have been specially de- ter-cooled operation if the cooling-water
signed to operate under the workbench supply is connected. The unit will auto-
and in general to be connected to an matically switch to air-cooled operation
air-extract duct. The refrigeration unit is if the water is not connected or if there
a development, in terms of thermodyna- is no cooling-water supply.
mics, of the unique Unistat Tango unit.
The term Unichiller indicates that it is uni-
versally suitable for heat dissipation.
Air-cooled refrigeration units which op-
erate under the workbench or in simi-
larly confined areas usually cause heat
to accumulate. Integrated Unichillers are
both air- and water-cooled. The waste
heat can therefore be removed either
using air or cooling water, as desired.

Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price
Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]
Unichiller ETH-1 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0011 3
Unichiller ETH-2 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0012 3
Unichiller ETH-3 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0013 3

ROTACOOL – a Co-product
The „Rotacool“ is a product co-devel- Benefits are:
oped with Heidolph to provide a dedi- – Independent cooling for individual Option:
cated cooling service to small bench top rotary evaporators Natural
nts
Rotary Evaporators. – Non-reliance on un-predictable
Refriger...a)
house water supplies (Page 50

– Consumes no additional bench space,


the rotary evaporator sits on top
– Compact and powerful

Also available from:


Heidolph Instruments GmbH & Co. KG
Walpersdorferstrasse 12, D-91126 Schwabach
Tel. 09122-9920-69
E-Mail: Heidolph.Instruments@Heidolph.de
Internet: www.heidolph.com

From a customer in New Zealand „…I’ve had


a regular trickle of inquisitive people into the
lab to view the Rotacool. I ran it with DCM and
our house vacuum. Using 200 ml in the flask,
I normally recover less than 50 ml. With the
Rotacool down at -10 I got 175 ml and with it
starting off at -20 I got 195 ml back so it does a
superb job of saving our vacuum system“.

Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price
Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]
RotaCool -20..40 0,42 0,35 0,22 10 0,2 470x580x420 659.0001 3

42 www.huber-online.com · Tel. +49-781-96030 Accessories see page 43, 45..


Accessories UNICHILLERS
Pump Pump duty [l/min] at [bar] Pumps
0,2 0,5 1,0 2,0 2,5 3,0 4,0
Instead of the standard pump you can
A 20 10 – – – – –
get stronger pumps for systems with a
B* 22 20 17 10 – 5 –
higher pressure drop.
B1* – 40 35 28 24 20 10
The bench top models with standard
C3** – – 65 60 45 40 25
pump A are for external closed systems
C4* ** – – 80 75 75 60 30
only. The air-cooled models UC006T to
D3** – – 140 120 110 90 50
UC012T and the water-cooled models
*Stronger pump options available from UC006T and UC012Tw and above ** Pump suitable for UC055 and above
UC012Tw to UC023Tw (not UC006Tw
Pump Reduction in cooling power Price and UC009Tw) are also available with a
stronger pump B which allows the tem-
B for A 150 W perature control of open baths and closed
B1 for B 150 W systems. Model names and Cat.No. will
C4 for C3 400 W then get the additional induction ‚B‘
D3 for C3 750 W (e.g. UC012Tw-3 B, Cat.No. 611.0013B).
D3 for C4 350 W
Ocassionally it might be necessarry to increase the unit housing to the next bigger size.

Sensors (standard cable length 1,5 m) Cat.No. G Price External Pt100 sensors
For external thermoregulation applica-
Ø 6 mm 180 mm 6138 1
tions there are different sensors avai-
with handle Ø 6 mm 200 mm 6105 1
lable. Special versions can be made on
Ø 8 mm 400 mm 6064 1
request.
mounted in protective pipe Ø 8 mm 170 mm 6205 1
M16x1 sensor for flow or return 6352 1
M16x1 sensor for flow or return double 6353 1
M30x1,5 sensor for flow or return 6509 1
M30x1,5 sensor for flow or return double 6363 1
Extension cable Pt100, 3m 6292 1

Control cables Compatible Control Cat.No. G Price Control cables for use with
CC RS232 / PC RS232 (3m) 6198 1 CC controllers
CC RS485 / open (3m) 6236 1
CC AIF / POKO open (3m) 6218 1 Control cables (for CC3) allow remote
CC AIF / open (3m) 6320 1 control via the RS232, RS485 or the ana-
CC complete / open (3m) 6319 1
logue interfaces (AIF). Open ends allow
flexibility to connect as required.
Y cable PC / AIF 6651 1
15-pole plug (plug only, no cable) 6335 1

Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price Control cables for use with
from to Note
CP PC RS232 6146 1
Unistat Control
CP Unistat controller Extension cable for control panel 6147 1 Control cable for use with RS232, RS485
CP RS485 Cable end open 6279 1 or analogue interface (AIF). Control ca-
CP Analog Cable end open 6254 1 bles can be configured to request.
CP Remote control CC3 6737 1
Y cable unistat/PC + analogue 6326 1

Other accessories Cat.No. G Price Other accessories


Float switch 6173 1
Trolley UC015 6235 2
Weather resistant option on request

www.huber-online.com · Tel. +49-781-96030 43


SPECIALS Models

Hotbox

HOTBOX – really hot units are the new,


compact recirculators to maintain the
temperature of externally open systems.
Safety first: The safety standards of in-
dustry and research are reached with an
adjustable overheat protection and level
protection (pressure switch). Casing and
pump made of stainless steel. HB2-HB5
with swirl castors. The temperature is
controlled with the exchangeable mic-
roprocessor controllers CC1, CC2 or CC3
with 3 years warranty.
HB1-3 HB5-3

Controller Options

CC1: CC2: CC3:


Basic and practical External process oriented Automation capable

Please see page 37 for full details.

Model Working Tempera- Pump Connections Heating Power Dimensions Cat.No. G Price
ture Range [°C] [l/min] [bar] [kW] W x D x H [mm]
Hotbox HB1 -1 45..250 M16x1 18 at 0,5 4,5 180x430x360 290.0051 3
Hotbox HB2 -1 60..250 M16x1 25 at 0,5 6,0 455x320x500 290.0061 3
Hotbox HB3 -1 60..250 M30x1,5 50 at 0,5 6,0 455x320x500 290.0071 3
Hotbox HB4 -1 60..250 M30x1,5 50 at 0,5 12,0 455x320x500 290.0081 3
Hotbox HB5 -1 60..250 M30x1,5 56 at 0,5 12,0 455x320x500 290.0091 3
3 controller options

Option:

Natural
nts
Refriger...a)
(Page 50
Beer „Force Ageing“
Thermostats
We offer a special air- or water chilled
chiller unit for the Beer Forcier-Test. Both
models are equipped with a comfortable
programmer for the usual change be-
tween 0°C and 60°C in the usual 24 hour
cycle. The BFT 2 is for 20 bottles in the
original Eurobox.
The CFC free units comply with the safe-
ty class FL, III. Casings and bath parts are
made of Stainless steel.

BFT1-2 BFT2w-2

Model Working Tempera- Bath Opening Bath Depth Heating Power Cooling Power Dimensions Cat.No. G Price
ture Range WxD at 20°C WxDxH
[°C] [mm] [mm] [kW] [kW] [mm]

BFT 1-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0005 2


BFT 1w-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0006 2
BFT 2-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0005 2
BFT 2w-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0006 2
BFT 4-2 0..80 300x400 300 2,0 0,35 540x600x775 414.0001 2
also available with controller CC3

44 www.huber-online.com · Tel. +49-781-96030 Accessories see page 45..


Thermal Fluids ACCESSORIES
DW-Therm -90°C...+200°C Operating range of thermal fluids
P20.330.90: plus 20°C +330°C 90 mm²/s at 25°C
Specifications M40.165.10: minus 40°C +165°C 10 mm²/s at 25°C
Appearance and odour: transparent, colourless or yellow
liquid with characteristic odour
Silane content: 99% -120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300
Viscosity: 2,0-2,2 mm²/sec at 20°C
M120.M08.02
Density: 0,88 g/cm³ at 15°C
Boiling range: 228-235°C DW-Therm M90.200.02
Solidification at: -137°C
Flash point: 101°C M90.055.03
Ignition temperature: 265°C M80.055.03

Properties M60.115.05
DW-Therm is a mixture of isometric triethoxysilanes and has M40.165.10
been developed for hydraulically sealed systems.
M20.235.20
Notes
M10.155.08
– broad working range from -90°C to +200°C (hydraulically
sealed systems) DW-Therm HT P20.330.90
– excellent thermooxidative stability at high temperatures
P20.190.40
– low viscosity at low temperatures
– low volatility and pleasant odour P20.275.50
– easy handling (no creeping like silicone oils)
-120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300
– good compatibility with silicone oils
– insoluble in water and environmentally friendly
– no known toxicity

Thermal Fluid (G1) Litre Cat.No. Price

DW-Therm HT +20°C...+330°C DW-Therm* M90.200.02 10 6479


DW-Therm HT* P20.330.90 5 6672
Specifications 10 6673
MinOil P20.190.40 5 6155
Appearance: clear, orange coloured liquid
20 6156
Content: 99,5% partially hydrogenated
SynOil M10.155.08 5 6159
terphenyls
10 6160
kinematic viscosity: 101 mm²/sec at 20°C
SilOil P20.275.50 5 6157
Density: 1,004 g/cm³ at 20°C
10 6158
Boiling starts at: approx. 350°C
SilOil M20.235.20 5 6161
Pour point: -33°C
10 6162
Flash point: approx. 190°C
SilOil M40.165.10 5 6163
Ignition temperature: approx. 390°C
10 6164
SilOil M60.115.05 5 6165
Properties
10 6166
DW-Therm HT is a mixture of partially hydrogenated terphe-
SilOil M80.055.03 5 6167
nyls. It is especially suited for high temperature applications
10 6168
using hydraulically sealed thermostats.
SilOil M80.100.03 5 6275
10 6276
Notes
SilOil M90.055.03 5 6258
– broad working range from +20°C to +330°C
10 6259
(hydraulically sealed system)
– long lifetime at high temperatures under inert atmosphere: Kryothermal S M120.M08.02 5 6282
3-4 years Antifreeze (Ethylenglycol) 10 6170
– good thermal properties for heat transfer 50 6171
– high oxidation stability Algae Protection 0,1 6172
– not classified as dangerous goods, no known toxicity * exclusive for Unistats

More information available at www.dws-synthese.de

www.huber-online.com · Tel. +49-781-96030 45


ACCESSORIES General

M16x1 Accessories M16x1 (G1) Cat.No. Price Adaptors Adaptor (G1) Cat.No. Price

Hose Connector NW 8 6086 M16x1 male to M16x1 male 6278


Hose Connector NW 12 6087
M16x1 female to M16x1 female 6359
Blank Plug 6088
M16x1 male to 1/2“ male 6299
Nut 6089
M16x1 male to 1/2“ female 6364
Micro Hose Connector NW 3,2 6090

90° Adaptor 6195 M16x1 female to 1/2“ male 6360

Ball Valve 6091 M16x1 female to 1/2“ female 6229

2-way Header 6194 M16x1 male to 3/4“ female 5443


3-way Header 6193
4-way Header 6187
M16x1 female to 3/4“ female 6361
5-way Header 6815

M16x1 female to M30x1,5 male 6431


2-way Valve System 6284
3-way Valve System 6285
4-way Valve System 6286 M16x1 male to M30x1,5 male 6449
5-way Valve System 6816
M16x1 male to M30x1,5 female 6454

M24x1,5 Accessories M24x1,5 (G1) Cat.No. Price


M24x1,5 female to M30x 1,5 male 6723

90° Adaptor 9256 M24x1,5 female to M16x1 male 6724


Ball Valve 9236
2-way Header 9233 M24x1,5 female to 3/4“ NPT female 6874
3-way Header 9234
4-way Header 9235 M24x1,5 male to M16x1 female 6945
2-way Valve System 9245
3-way Valve System 9246 M30x1,5 male to M30x1,5 male 6448
4-way Valve System 9247
M30x1,5 female to 3/8“ male 6445
M30x1,5 Accessories M30x1,5 (G1) Cat.No. Price
M30x1,5 male to 1/2“ male 6393
90° Adaptor 6461
M30x1,5 male to 1/2“ female 6394
Ball Valve 6451
M30x1,5 female to 1/2“ male 6391
2-way Header 6420
3-way Header 6421
M30x1,5 female to 1/2“ female 6392
4-way Header 6422

2-way Header with Ball Valves 6423 M30x1,5 male to 3/4“ male 6447
3-way Header with Ball Valves 6463
4-way Header with Ball Valves 6464 M30x1,5 male to 3/4“ female 6442

M30x1,5 female to 3/4“ NPT male 6472


M38x1,5 Accessories M38x1,5 (G1) Cat.No. Price
M30x1,5 female to 3/4“ female 6452
90° Adaptor 6699
Ball Valve 6700
M30x1,5 male to 1“ male 6444
2-way Header 6706
3-way Header 6707
4-way Header 6708 M30x1,5 female to 1“ female 6453
2-way Valve System 6709
3-way Valve System 6710 1/2“ female to 1/2“ female 6358
4-way Valve System 6711
1/2“ female to 3/4“ NPT female 6356
1/2“ Accessories 1/2“ and 3/4“ (G1) Cat.No. Price
M38x1,5 female to 1“ NPT male 6600
3/4“ Hose connections 1/2“ 2294
for 3/8“ hose M38x1,5 female to M30x1,5 male 6612

M38x1,5 female to 3/4“ male 6665


Hose connections 3/4“ 2295
for 1/2“ hose
Other adaptors on request

46 www.huber-online.com · Tel. +49-781-96030


General ACCESSORIES
Hoses
Hose max. [°C] Length Cat.No. G Price

NW 3,2 PVC 60 variable 6072 1


NW 8 PVC 60 variable 6071 1
NW 12 PVC 60 variable 6070 1
NW 8 Perbunan 120 variable 6075 1
NW 12 Perbunan 120 variable 6073 1
NW 8 Silicon 180 variable 6077 1
NW 12 Silicon 180 variable 6076 1
NW 8 Viton 200 variable 6079 1
NW 12 Viton 200 variable 6078 1
NW 8 Teflon 200 variable 6350 1
NW 12 Teflon 200 variable 6351 1

Insulated hose Temperature Length Cat.No. G Price


Range
NW 10 M16x1 -100...350°C 100 cm 6084 1
NW 10 M16x1 -100...350°C 150 cm 6085 1
NW 10 M16x1 -100...350°C 200 cm 6136 1
NW 10 M16x1 -100...350°C 300 cm 6255 1
NW 12 M24x1,5 -120...400°C 100 cm 6784 1
NW 12 M24x1,5 -120...400°C 150 cm 6785 1
NW 12 M24x1,5 -120...400°C 200 cm 6786 1
NW 12 M24x1,5 -120...400°C 300 cm 6787 1
NW 20 M30x1,5 -100...350°C 100 cm 6426 1
NW 20 M30x1,5 -100...350°C 150 cm 6386 1
NW 20 M30x1,5 -100...350°C 200 cm 6427 1
NW 20 M30x1,5 -100...350°C 300 cm 6428 1
NW 25 M38x1,5 -100...350°C 100 cm 6655 1
NW 25 M38x1,5 -100...350°C 150 cm 6656 1
NW 25 M38x1,5 -100...350°C 200 cm 6657 1
NW 25 M38x1,5 -100...350°C 300 cm 6658 1

Cooling Water Hoses


Cooling Water Hose Temperature Length Cat.No. G Price
(Flexible braided hose) Range
1/2“ -10...100°C 100 cm 16851 1
1/2“ -10...100°C 150 cm 16852 1
1/2“ -10...100°C 200 cm 16853 1
3/4“ -10...100°C 100 cm 16854 1
3/4“ -10...100°C 150 cm 16855 1
3/4“ -10...100°C 200 cm 16856 1
1“ -10...100°C 100 cm 16857 1
1“ -10...100°C 150 cm 16858 1
1“ -10...100°C 200 cm 16859 1

Hose insulation Digital thermometer


Hose insulation Internal Ø Thickness Cat.No. G Price for precise temperature measurement
from -60 to +400°C
For hose: Digital thermometer D400 Cat.No. Price
13 mm 7 mm NW 8 6083 1 (G1)
17 mm 7 mm NW 12 6082 1 Digital thermometer D400 307.0001
17 mm 12 mm NW 12 3968 1 Handle D400 for dense masses 6116
For metal hose: Imitation leather pocket for D400 6190
42 mm 22 mm M16x1 6375 1 Battery 9V IEC 6F22 (pack of 3) 6191
57 mm 23 mm M30x1,5 6377 1 Heat transfer paste 15 g 6122
50 mm 22 mm 1/2“ 6376 1 Heat transfer paste 50 g 6149

www.huber-online.com · Tel. +49-781-96030 47


QUICK FINDER
Quick Finder Thermostats

Thermal Control
Required

Internal External
(e.g. Sample immersion, (e. g. reactor,
test tubes etc.) reaction block, rotary
evap. etc.)

Open Bath Systems Low Volume Sealed


Systems

Above 30°C Below 30°C 80°C…400°C 100°C…300°C -120°C…300°C


Heating Heating + Cooling Heating Heating Heating +
Cooling

Unistat range
Low High Low High CC400 Series
Demand Demand Demand Demand CC401 Series

„A“ Series „K“ Series


„B“ Series „DC“ Series Unistat range
„TC“ Series T326 Series
T327 Series

VPC Range VPC Range Unistat range


304B Series Variostat Tango
308B Series Ministat Series 34x Series
315B Series 14x Series
15x Series
16x Series
36x Series
38x Series
39x Series
29x Series
42x Series

48 www.huber-online.com · Tel. +49-781-96030


QUICK FINDER
Quick Finder Chillers

 



         
            
 

   


 
 



  
     



 

    





 

    







  
     





www.huber-online.com · Tel. +49-781-96030 49


TECHNICAL DATA

g
in

xH

ty
ol

y
ty

la
t

ili
co
e

er

xD
ci

sp
ng

e n th

ab
ns
in

pa
er

W
Cooling Power at

Di
m wi
ge

Ra

t
ol

er

tI

S
at

Ca

g
Pa

of
co

ce e

e
e

in
um

la m

r
ur

g
Po

tu
en
e

ith

ith

in

sp olu

tio
t
gu

ra
ra

ill

Op
g

Vo
w

lu
tin

Di V

pe
pe

°C
el

lo

.F

C
in

in

so
h

th

th

°C
od

ta

00
m
m


a

in

C
t
Tm

Tm

He

Ba

Ba

Ba

Re
Ca

Te
Te

30

20

10

20


M

-2

-4

-6

-8

-1
m
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW
COMPATIBLE CONTROL THERMOSTATS
CC1-E 7 25...200 -30 20 2 0.1 0.02
CC1-300B2X vpc 7 28...300 -20 2 0.1 0.02
CC1-300B4X vpc 7 28...300 -20 3.0 / 4.0 0.1 0.02
CC1-105A 8 25...100 -30 20 2 5 5 120x110x150 0.1 0.02
CC1-106A 8 25...100 -30 20 2 6 6 120x210x150 0.1 0.02
CC1-107A 8 25...100 -30 20 2 7 7 120x310x150 0.1 0.02
CC1-111A 8 25...100 -30 20 2 11 11 302x165x150 0.1 0.02
CC1-118A 8 25...100 -30 20 2 18 18 302x325x150 0.1 0.02
CC1-130A Visco 3 8 20...80 20 2 31 90x90x370 0,01 0,01
CC1-130A Visco 5 8 20...80 20 2 31 Ø51x370 0,01 0,01
CC1-208B 9 25...200 -30 20 2 8.5 8.5 235x165x150 0.1 0.02
CC1-212B 9 25...200 -30 20 2 12 12 295x193x150 0.1 0.02
CC1-215B 9 25...200 -30 20 2 15 15 295x193x200 0.1 0.02
CC1-220B 9 25...200 -30 20 2 20 20 295x370x150 0.1 0.02
CC1-225B 9 25...200 -30 20 2 25 25 295x370x200 0.1 0.02
CC1-202C 10 45...200 -30 20 2 1.8 1.8 Ø25x150 0.1 0.05
CC1-205B 10 45...200 -30 20 2 4.5 3.1 3.1 105x90x150 0.1 0.05
CC1-304B vpc 10 28...300 -20 2 4 100x130x145 0.1 0.02
CC1-308B vpc 10 28...300 -20 3 8.5 5.2 130x110x155 0.1 0.02
CC1-315B vpc 10 28...300 -20 3.0 / 4.0 15 8.5 270x145x200 0.1 0.02
CC1-K12 11 -20...200 2 12 8 295x193x150 0.1 0.02 0.18
CC1-K15 11 -20...200 2 15 11 295x193x200 0.1 0.02 0.2
CC1-K20 11 -30...200 2 20 12 295x370x150 0.1 0.02 0.35 0.21
CC1-K25 11 -30...200 2 25 17 295x370x200 0.1 0.02 0.35 0.21
variostat cc-1 12 -30...150 1 0.1 0.02 0.3 0.3 0.2 0.12
CC1-K6 13 -25...200 2 4.5 150x140x150 0.1 0.02 0.15 0.05
ministat 125-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.21 0.05
ministat 125w-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.2 0.1
ministat 230-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25
ministat 230w-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25
ministat 240-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03
ministat 240w-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03
CC1-305 vpc 16 -30...150 1.5 20 300x330x150 0.1 0.02 0.35 0.35 0.35 0.23
CC1-405 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03
CC1-405w vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03
CC1-415 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05
CC1-415wl vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05
CC1-410wl vpc 16 -45...200 1.5 / 4.5 22 8.5 280x280x200 0.1 0.02 0.8 0.8 0.8 0.5 0.1
CC1-505 vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15
CC1-505wl vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15
CC1-510 vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.1 2.1 2.1 1 0.4
CC1-510w vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.4 2.4 2.4 1 0.4
CC1-515 vpc 17 -55...100 3 26 15 260x260x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6
CC1-515w vpc 17 -55...100 3 18 11 270x150x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6
CC1-520w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 5 5 5 3 1.5
CC1-525w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 7 7 5 3 1.5
CC1-705 vpc 18 -75...100 1.5 5 120x110x150 0.1 0.02 0.25 0.25 0.25 0.2 0.15 0.1
CC1-805 vpc 18 -80...100 1.5 5 120x110x150 0.1 0.02 0.5 0.5 0.5 0.4 0.3 0.3
CC1-820 vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14
CC1-820w vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids

50 www.huber-online.com · Tel. +49-781-96030


TECHNICAL DATA

ne
p

p
um

um
p

tio io n

hi

re
p
m

an on
em ure
eP

ac
nP
um
Pu

tu
t
ec

i
nm

ct
t
ur

ra
io
P

ra
re

ot

*
e
n
ss

pe
ct
n

t*
io

pe
xH

nn
su

Pr
io
e

Su

at
Pr

em
n

Co
es

ct

an p

xD
re

er
io

er
m

te
-

rd
Su

tT
e-
Pr

tT
ri g
tu
te

sW
ct

er
Pu

rig
ro
da

ly

en
t

ra
Ra

en
Ra

ef
s-

s-

at
lP

pp

ef
nn

pe

on

fr

bi

W
bi
io
s

w
w

ve

su

lR
St
re

re

Co

go

m
m

si

m
lo

at
lo

o.
t
Le

.A

ra
.P

.P

te

er
gh
en

in

el
ty

.A
.F

ul
.F

lin
p

t.N
tu
er
fe

ol

od
m
ax

ax

ax
rc
x

ei
m
x

in
o
ma

Na
ma

Pu

Sa

Ov

Po

Co

Ca
Co
Lo

Di

W
Ci

M
m

m
l/min bar l/min bar mm kg V; Hz °C °C

10 0.2 FL Yes Yes 120x135x300 4 230;50/60 5 32 688.0051 CC1-E


33 0.7 22 0.4 M16x1 FL Yes Yes 345x190x380 11 230;50/60 5 32 683.0011BX CC1-300B2X vpc
34 0.7 22 0.4 M16x1 FL Yes Yes 345x190x395 13 230;50/60 / 400;3~N;50* 5 32 684.0011BX CC1-300B4X vpc
10 0.2 M16x1 FL Yes Yes 132x280x320 4.5 230;50/60 5 32 405.0001 CC1-105A
10 0.2 M16x1 FL Yes Yes 132x380x320 5 230;50/60 5 32 405.0011 CC1-106A
10 0.2 M16x1 FL Yes Yes 132x480x320 5 230;50/60 5 32 405.0021 CC1-107A
10 0.2 M16x1 FL Yes Yes 333x313x325 6.5 230;50/60 5 32 405.0031 CC1-111A
10 0.2 M16x1 FL Yes Yes 333x473x325 8 230;50/60 5 32 405.0041 CC1-118A
10 0.2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0051 CC1-130A Visco 3
10 0,2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0061 CC1-130A Visco 5
10 0.2 M16x1 FL Yes Yes 290x350x375 10 230;50/60 5 32 407.0001 CC1-208B
10 0.2 M16x1 FL Yes Yes 350x375x375 11 230;50/60 5 32 407.0011 CC1-212B
10 0.2 M16x1 FL Yes Yes 350x375x420 12 230;50/60 5 32 407.0021 CC1-215B
10 0.2 M16x1 FL Yes Yes 350x555x375 14 230;50/60 5 32 407.0031 CC1-220B
10 0.2 M16x1 FL Yes Yes 350x555x420 16 230;50/60 5 32 407.0041 CC1-225B
10 0.2 M16x1 FL Yes Yes 150x215x350 7.5 230;50/60 5 32 685.0011 CC1-202C
10 0.2 M16x1 FL Yes Yes 150x285x350 8.5 230;50/60 5 32 686.0011 CC1-205B
34 0.7 22 0.4 M16x1 FL Yes Yes 210x310x390 13 230;50/60 5 32 679.0001 CC1-304B vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 240x405x390 18 230;50/60 5 32 683.0021 CC1-308B vpc
34 0.7 22 0.4 M16x1 FL Yes Yes 335x385x430 22 230; 50/60 / 400;3~N;50* 5 32 684.0011 CC1-315B vpc
10 0.2 M16x1 FL Yes Yes 350x558x375 24 230;50 AIR 5 32 S 653.0021 CC1-K12
10 0.2 M16x1 FL Yes Yes 350x558x420 28 230;50 AIR 5 32 S 645.0031 CC1-K15
10 0.2 M16x1 FL Yes Yes 350x558x550 34 230;50/60 AIR 5 32 S 646.0031 CC1-K20
10 0.2 M16x1 FL Yes Yes 350x558x600 36 230;50/60 AIR 5 32 S 647.0031 CC1-K25
18 0.6 12 0.3 M16x1 FL Yes Yes 183x455x395 24 230;50/60 AIR 5 32 O 654.0011 variostat cc-1
10 0.2 M16x1 FL Yes Yes 210x370x535 20 230;50 AIR 5 32 O 666.0021 CC1-K6
27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 AIR 5 32 O 740.0001 ministat 125-1
27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 WATER 5 32 1/2“ O 740.0011 ministat 125w-1
27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 AIR 5 32 O 741.0001 ministat 230-1
27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 WATER 5 32 1/2“ O 741.0011 ministat 230w-1
27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 AIR 5 32 O 742.0001 ministat 240-1
27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 WATER 5 32 1/2“ O 742.0011 ministat 240w-1
33 0.7 22 0.4 M16x1 FL Yes Yes 350x575x600 43 230;50 AIR 5 32 O 690.0011 CC1-305 vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 AIR 5 32 O 697.0011 CC1-405 vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 WATER 5 32 1/2“ O 697.0021 CC1-405w vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 694.0011 CC1-415 vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 694.0021 CC1-415wl vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 420x590x700 72 230;50 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 695.0011 CC1-410wl vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 696.0011 CC1-505 vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 696.0021 CC1-505wl vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 99 400;3~N;50 AIR 5 32 O 564.0021 CC1-510 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 96 400;3~N;50 WATER 5 32 1/2“ O 564.0031 CC1-510w vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 98 400;3~N;50 AIR 5 32 O 651.0011 CC1-515 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 98 400;3~N;50 WATER 5 32 1/2“ O 651.0021 CC1-515w vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 698.0011 CC1-520w vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 700.0001 CC1-525w vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 78 230;50 / 400;3~N;50* AIR 5 32 O 692.0011 CC1-705 vpc
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 81 230;50 / 400;3~N;50* AIR 5 32 O 693.0011 CC1-805 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 AIR 5 32 O 567.0021 CC1-820 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 WATER 5 32 1/2“ O 567.0031 CC1-820w vpc
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request

www.huber-online.com · Tel. +49-781-96030 51


TECHNICAL DATA

g
in

xH

ty
ol

y
ty

la
t

ili
co
e

er

xD
ci

sp
ng

e n th

ab
ns
in

pa
er

W
Cooling Power at

Di
m wi
ge

Ra

t
ol

er

tI

S
at

Ca

g
Pa

of
co

ce e

e
e

in
um

la m

r
ur

g
Po

tu
en
e

ith

ith

in

sp olu

tio
t
gu

ra
ra

ill

Op
g

Vo
w

lu
tin

Di V

pe
pe

°C
el

lo

.F

C
in

in

so
h

th

th

°C
od

ta

00
m
m


a

in

C
t
Tm

Tm

He

Ba

Ba

Ba

Re
Ca

Te
Te

30

20

10

20


M

-2

-4

-6

-8

-1
m
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW
CC1-815 vpc 18 -85...100 1.5 5 120x110x150 0.1 0.02 1 1 1 0.8 0.75 0.6
CC1-905 vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34
CC1-905w vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34
DC30 19 -30...50 0.15 0.07
DC31 19 -30...50 0.35 0.1
DC32 19 -30...50 0.47 0.12
TC45 19 45...100 0.24 0.18 0.05
TC45E 19 -45...100 0.1 0.5 0.24 0.18 0.05
TC50 19 -50...50 0.3 0.26
TC50E 19 -50...50 0.1 0.5 0.3 0.26
TC100 19 -100...40 0.15 0.14
TC100E 19 -100...40 0.1 0.5 0.15 0.14
K12 20 -20...200 12 295x320x150 0.18
K15 20 -20...200 15 295x320x200 0.2
K20 20 -30...200 20 295x500x150 0.35 0.21
K25 20 -30...200 25 295x500x200 0.35 0.21
UNISTATS
unistat T326 29 65...300 15 3.0 / 6.0 1.45 0.1 0.02
unistat T326 HT 29 65...300 3.0 / 6.0 1.9 0.1 0.02 3.2 2.3 0.6
unistat T326w HT 29 65...300 15 3.0 / 6.0 1.9 0.1 0.02 10 10 10
unistat T327 29 65...300 15 12 3.5 0.1 0.02
unistat T327w HT 29 65...300 15 12 3.5 0.1 0.02 10 10 6
unistat cc 400-3 29 75...400 3 0.8 0.1 0.05
unistat cc 401-3 29 50...400 3.0 / 9.0 3 0.1 0.05
unistat cc 401w HT-3 29 50...400 3.0 / 9.0 2.3 0.1 0.05 10 10 10
unistat tango 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 0.7 0.7 0.7 0.7 0.4 0.05
unistat tango HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.3 0.7 0.7 0.4 0.05
unistat 340 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1
unistat 340w 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1
unistat 340 HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.8 1 1 0.6 0.1
unistat 340w HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.8 1 1 0.6 0.1
unistat 140 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2
unistat 140w 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2
unistat 140w-FB 31 -40...200 2 4.7 0.1 0.02 2 2 2 2.5 1.8 0.2
unistat 140 HT 31 -40...300 2 5 0.1 0.02 3.2 2.3 2.7 2 2.5 1.8 0.2
unistat 140w HT 31 -40...300 2 5 0.1 0.02 3.5 3 2.7 2 2.5 1.8 0.2
unistat 141 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.3
unistat 141w 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2
unistat 141w-FB 31 -40...200 4 4.1 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2
unistat 141 HT 31 -40...300 4 5 0.1 0.02 3.2 4 3.5 3.5 3.5 2.2 0.3
unistat 141w HT 31 -40...300 4 5 0.1 0.02 3.5 4 3.5 3.5 3.5 2.2 0.2
unistat 150w 31 -50...200 6 4.3 0.1 0.02 5 5 5 2.8 0.9
unistat 150w HT 31 -50...300 6 6.4 0.1 0.02 3.5 6 5.5 5 2.8 0.9
unistat 151w 31 -55...200 6 5.1 0.1 0.02 6 6 6 4.2 1.5
unistat 151w-FB 31 -55...200 6 8.6 0.1 0.02 5 5 6 4.2 1.5
unistat 160w 31 -60...200 6 5.65 0.1 0.02 7 7 7 6 3.3 0.8
unistat 161w 31 -60...200 12 5.65 0.1 0.02 9 9 9 7 5 1
unistat 162w 31 -60...200 12 5.2 0.1 0.02 12 12 12 12 7 2
unistat 163w 31 -60...200 12 3.4 0.1 0.02 16 16 16 16 13.5 8.4 2.2
unistat 164w 31 -60...200 24 20 0.1 0.02 22 22 20 18 15 5
unistat 165w 31 -60...200 24 21 0.1 0.02 26 26 25 24 18 6
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids

52 www.huber-online.com · Tel. +49-781-96030


TECHNICAL DATA

ne
p

p
um

um
p

tio io n

hi

re
p
m

an on
em ure
eP

ac
nP
um
Pu

tu
t
ec

i
nm

ct
t
ur

ra
io
P

ra
re

ot

*
e
n
ss

pe
ct
n

t*
io

pe
xH

nn
su

Pr
io
e

Su

at
Pr

em
n

Co
es

ct

an p

xD
re

er
io

er
m

te
-

rd
Su

tT
e-
Pr

tT
ri g
tu
te

sW
ct

er
Pu

rig
ro
da

ly

en
t

ra
Ra

en
Ra

ef
s-

s-

at
lP

pp

ef
nn

pe

on

fr

bi

W
bi
io
s

w
w

ve

su

lR
St
re

re

Co

go

m
m

si

m
lo

at
lo

o.
t
Le

.A

ra
.P

.P

te

er
gh
en

in

el
ty

.A
.F

ul
.F

lin
p

t.N
tu
er
fe

ol

od
m
ax

ax

ax
rc
x

ei
m
x

in
o
ma

Na
ma

Pu

Sa

Ov

Po

Co

Ca
Co
Lo

Di

W
Ci

M
m

m
l/min bar l/min bar mm kg V; Hz °C °C
33 0.7 22 0.4 M16x1 FL Yes Yes 550x600x890 139 230;50 AIR 5 32 O 699.0001 CC1-815 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 162 400;3~N;50 AIR 5 32 O 568.0011 CC1-905 vpc
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 170 400;3~N;50 WATER 5 32 1/2“ O 568.0021 CC1-905w vpc
M16x1 No No 190x250x360 16 230;50 AIR 5 32 O 574.0002 DC30
M16x1 No No 250x310x400 25 230;50/60 AIR 5 32 S 575.0002 DC31
M16x1 No No 280x340x460 30 230;50 AIR 5 32 O 652.0002 DC32
No No 190x250x360 16 230;50 AIR S 570.0008 TC45
No No 190x250x360 16 230;50 AIR S 570.0009 TC45E
No No 250x310x400 25 230;50/60 AIR S 572.0006 TC50
No No 250x310x400 25 230;50/60 AIR S 572.0007 TC50E
No No 280x440x525 55 230;50 AIR O 573.0007 TC100
No No 280x440x525 55 230;50 AIR O 573.0008 TC100E
No No 350x558x215 20 230;50 AIR S 653.0020 K12
No No 350x558x240 19 230;50 AIR S 645.0021 K15
No No 350x558x370 30 230;50/60 AIR S 646.0021 K20
No No 350x558x420 35 230;50/60 AIR S 647.0021 K25

15 0.5 M16x1 FL Yes Yes 425x220x635 35 230;50/60 / 400;3~N;50* 5 32 1/2“ 532.0002 unistat T326
15 0.5 M16x1 FL Yes Yes 425x220x635 36 230;50/60 / 400;3~N;50* 5 32 531.0002 unistat T326 HT
15 0.5 M16x1 FL Yes Yes 425x220x635 42 230;50/60 / 400;3~N;50* 5 32 1/2“ 530.0002 unistat T326w HT
70 1.6 M30x1,5 FL Yes Yes 460x550x1336 90 400;3~N;50 5 32 1/2“ 525.0002 unistat T327
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 124 400;3~N;50 5 32 1/2“ 526.0002 unistat T327w HT
27 0.75 FL Yes Yes 190x240x635 21 230;50/60 5 32 1/2“ 400.0003 unistat cc 400-3
31 1 FL Yes Yes 285x330x735 37 230;50 / 400;3~N;50* 5 40 1/2“ 400.0023 unistat cc 401-3
31 1.0 FL Yes Yes 285x330x735 45 230;50 / 400;3~N;50* 5 40 1/2“ 400.0033 unistat cc 401w HT-3
15 0.5 M16x1 FL Yes Yes 425x270x636 58 230;50/60 / 400;3~N;50* AIR 5 32 O 534.0003 unistat tango
15 0.5 M16x1 FL Yes Yes 425x270x636 59 230;50/60 / 400;3~N;50* AIR 5 32 O 533.0003 unistat tango HT
20 0.7 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* AIR 5 32 O 710.0004 unistat 340
20 0.7 M16x1 FL Yes Yes 425x270x636 55 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 710.0003 unistat 340w
15 0.5 M16x1 FL Yes Yes 425x300x636 65 230;50/60 / 400;3~N;50* AIR 5 32 O 711.0003 unistat 340 HT
15 0.5 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 711.0004 unistat 340w HT
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 155 400;3~N;50 AIR 5 32 R 544.0004 unistat 140
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 545.0004 unistat 140w
100 1.5 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 545.0004FB unistat 140w-FB
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 190 400;3~N;50 AIR 5 32 R 712.0001 unistat 140 HT
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 178 400;3~N;50 WATER 5 32 1/2“ R 712.0002 unistat 140w HT
90 1.5 M30x1,5 FL Yes Yes 460x550x1336 161 400;3~N;50 AIR 5 32 R 550.0005 unistat 141
90 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 551.0005 unistat 141w
70 1.6 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 551.0005FB unistat 141w-FB
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 AIR 5 32 R 713.0003 unistat 141 HT
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 713.0004 unistat 141w HT
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 163 400;3~N;50 WATER 5 32 1/2“ R 715.0001 unistat 150w
80 1.5 M30x1,5 FL Yes Yes 460x550x1336 180 400;3~N;50 WATER 5 32 1/2“ R 716.0001 unistat 150w HT
60 1.5 M30x1,5 FL Yes Yes 540x600x1336 203 400;3~N;50 WATER 5 32 1/2“ R 717.0001 unistat 151w
60 1.5 M30x1,5 FL Yes Yes 920x635x740 202 400;3~N;50 WATER 5 32 1/2“ R 717.0001FB unistat 151w-FB
50 1.5 M30x1,5 FL Yes Yes 600x700x1515 348 400;3~N;50 WATER 5 32 1/2“ R 552.0005 unistat 160w
50 1.5 M30x1,5 FL Yes Yes 600x700x1515 358 400;3~N;50 WATER 5 32 1/2“ R 556.0005 unistat 161w
90 2.5 M30x1,5 FL Yes Yes 700x800x1515 440 400;3~N;50 WATER 5 32 3/4“ R 557.0005 unistat 162w
90 2.5 M30x1,5 FL Yes Yes 700x800x1515 448 400;3~N;50 WATER 5 32 3/4“ R 559.0004 unistat 163w
110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 740 400;3~N;50 WATER 5 32 3/4“ R 719.0001 unistat 164w
110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 734 400;3~;50 WATER 5 32 3/4“ R 720.0001 unistat 165w
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request

www.huber-online.com · Tel. +49-781-96030 53


TECHNICAL DATA

g
in

xH

ty
ol

y
ty

la
t

ili
co
e

er

xD
ci

sp
ng

e n th

ab
ns
in

pa
er

W
Cooling Power at

Di
m wi
ge

Ra

t
ol

er

tI

S
at

Ca

g
Pa

of
co

ce e

e
e

in
um

la m

r
ur

g
Po

tu
en
e

ith

ith

in

sp olu

tio
t
gu

ra
ra

ill

Op
g

Vo
w

lu
tin

Di V

pe
pe

°C
el

lo

.F

C
in

in

so
h

th

th

°C
od

ta

00
m
m


a

in

C
t
Tm

Tm

He

Ba

Ba

Ba

Re
Ca

Te
Te

30

20

10

20


M

-2

-4

-6

-8

-1
m
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW
unistat 166w 31 -60...200 30 27.5 0.1 0.02 30 30 30 27 20 6
unistat 167w 31 -60...200 36 30 0.1 0.02 40 40 40 40 22 7
unistat 169w 31 -60...200 48 28 0.1 0.02 65 65 65 65 38 11
unistat 1060w 31 -60...200 96 40 0.1 0.02 130 130 80 60 20
unistat minus 55w-FB-3 31 -55...50 2 16.7 0.1 1 6 6 4.2 1.5
unistat minus 85w-3-FB 31 -85...50 2 3 0.1 1.5 2.3 2.3 2.3 2 1.2 0.2
unistat minus 90w-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75
unistat minus 90w-FB-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75
unistat 360 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3
unistat 360w 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3
unistat 360 HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.4 0.6 0.6 0.6 0.6 0.3
unistat 360w HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.4 0.6 0.6 0.6 0.6 0.3
unistat 380 32 -80...200 2 3.8 0.1 0.02 1.3 1.3 1.3 1.3 1.3 1.3 0.9 0.2
unistat 380w 32 -80...200 2 3.2 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.5 0.9 0.2
unistat 380 HT 32 -80...300 2 3.8 0.1 0.02 3.2 2.3 1.8 1.3 1.3 1.3 1.3 0.9 0.2
unistat 380w HT 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2
unistat 380w HT-FB 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2
unistat 385 32 -85...200 3 2.9 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3
unistat 385w 32 -85...200 3 3 0.1 0.02 2.3 0 2.3 2.3 2.3 2 1.2 0.3
unistat 385w-FB 32 -85...200 3 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3
unistat 385 HT 32 -85...300 3 3.8 0.1 0.02 3.2 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3
unistat 385w HT 32 -85...300 3 4.6 0.1 0.02 3.5 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3
unistat 386 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6
unistat 386w 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6
unistat 390w 32 -90...200 6 4.3 0.1 0.02 5.2 5.2 5.2 5 4.2 3.1 0.9
unistat 390w HT 32 -90...300 6 6.4 0.1 0.02 4.5 2.6 7 5.2 5.2 5 4.2 3.1 0.9
unistat 290w 32 -90...200 12 5.5 0.1 0.02 16 16 16 16 16 15 13.5 3.5
unistat 291w 32 -90...200 24 5.5 0.1 0.02 19 19 19 19 19 17 15 6
unistat 292 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10
unistat 292w 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10
unistat 420w 33 -120...100 2 3.6 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.4 1.3 1
unistat 420w HT 33 -120...300 2 5 0.1 0.02 3.5 3.2 3 1.5 1.5 1.5 1.5 1.4 1.3 1
unistat 421w 33 -120...100 4 7 0.1 0.02 2.5 2.5 2.5 2.5 2.5 2.5 2 2
CAL 1 33 -20...150 1 7 0 Ø120 x 400 0.1 0.01 0.3
CAL 2 33 -40...200 1.5 7 7 Ø120 x 400 0.1 0.01 0.5
CAL 3 33 -80...150 1.5 7 7 Ø120 x 400 0.1 0.01 0.3
CAL 4 33 25...250 1.5 7 7 Ø120 x 400 0.1 0.01
UNICHILLERS
minichiller 38 -20...40 1.4 0.1 1 0.2 0.07
minichiller w 38 -20...40 1.4 0.1 1 0.2 0.07
minichiller-1 38 -20...40 1.4 0.1 1 0.2 0.07
minichiller w-1 38 -20...40 2.6 0.1 1 0.2 0.07
UC006A-1 38 -20...40 1.25 0.1 0.5 0.5
UC007 38 -20...40 4.4 0.1 1 0.55 0.16
UC007-1 38 -20...40 4.4 0.1 1 0.55 0.16
UC015-1 38 -10...40 0.9 0.1 0.5 1
UC015w-1 38 -10...40 0.9 0.1 0.5 1
UC022-1 38 -10...40 3.5 0.1 0.5 1.6
UC022w-1 38 -10...40 0.8 0.1 0.5 1.6
UC020-1 38 -10...40 0.8 0.1 0.5 2
UC020w-1 38 -10...40 0.8 0.1 0.5 2
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids

54 www.huber-online.com · Tel. +49-781-96030


TECHNICAL DATA

ne
p

p
um

um
p

tio io n

hi

re
p
m

an on
em ure
eP

ac
nP
um
Pu

tu
t
ec

i
nm

ct
t
ur

ra
io
P

ra
re

ot

*
e
n
ss

pe
ct
n

t*
io

pe
xH

nn
su

Pr
io
e

Su

at
Pr

em
n

Co
es

ct

an p

xD
re

er
io

er
m

te
-

rd
Su

tT
e-
Pr

tT
ri g
tu
te

sW
ct

er
Pu

rig
ro
da

ly

en
t

ra
Ra

en
Ra

ef
s-

s-

at
lP

pp

ef
nn

pe

on

fr

bi

W
bi
io
s

w
w

ve

su

lR
St
re

re

Co

go

m
m

si

m
lo

at
lo

o.
t
Le

.A

ra
.P

.P

te

er
gh
en

in

el
ty

.A
.F

ul
.F

lin
p

t.N
tu
er
fe

ol

od
m
ax

ax

ax
rc
x

ei
m
x

in
o
ma

Na
ma

Pu

Sa

Ov

Po

Co

Ca
Co
Lo

Di

W
Ci

M
m

m
l/min bar l/min bar mm kg V; Hz °C °C
100 2.5 M38x1,5 FL Yes Yes 920x1200x1655 825 400;3~;50 WATER 5 32 3/4“ R 723.0001 unistat 166w
100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 724.0001 unistat 167w
100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 726.0001 unistat 169w
100 2.5 M38x1,5 FL Yes Yes 4500x2000x2000 3500 400;3~N;50 WATER 5 32 2“ R 733.0001 unistat 1060w
55 1.6 M30x1,5 FL Yes Yes 920x635x740 206 400;3~N;50 WATER 5 32 1/2“ R 717.0106 unistat minus 55w FB-3
18 0.7 M30x1,5 FL Yes Yes 1200x650x745 277 400;3~N;50 WATER 5 32 1/2“ R 549.0105 unistat minus 85w-3-FB
40 1.5 M30x1,5 FL Yes Yes 600x700x1550 392 400;3~N;50 WATER 5 32 1/2“ R 554.0112 unistat minus 90w-3
40 1.5 M30x1,5 FL Yes Yes 1500x700x900 399 400;3~N;50 WATER 5 30 1/2“ R 554.0109 unistat minus 90w-FB-3
25 0.8 M16x1 FL Yes Yes 425x400x720 88 230;50 / 400;3~N;50* AIR 5 32 O 536.0006 unistat 360
25 0.8 M16x1 FL Yes Yes 425x400x720 87 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 536.0005 unistat 360w
16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* AIR 5 32 O 535.0006 unistat 360 HT
16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 535.0005 unistat 360w HT
35 0.8 M30x1,5 FL Yes Yes 460x600x1346 186 400;3~N;50 AIR 5 32 R 539.0006 unistat 380
35 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 540.0006 unistat 380w
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 AIR 5 32 R 537.0006 unistat 380 HT
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006 unistat 380w HT
30 0.8 M30x1,5 FL Yes Yes 1200x650x740 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006FB unistat 380w HT-FB
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 208 400;3~N;50 AIR 5 32 R 548.0006 unistat 385
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 204 400;3~N;50 WATER 5 32 1/2“ R 549.0006 unistat 385w
30 0.8 M30x1,5 FL Yes Yes 1200x650x740 234 400;3~N;50 WATER 5 30 1/2“ R 549.0005FB unistat 385w-FB
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 AIR 5 32 R 546.0006 unistat 385 HT
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 WATER 5 32 1/2“ R 547.0006 unistat 385w HT
32 0.8 M30x1,5 FL Yes Yes 540x650x1490 245 400;3~N;50 AIR 5 32 R 721.0002 unistat 386
32 0.8 M30x1,5 FL Yes Yes 540x650x1490 238 400;3~N;50 WATER 5 32 1/2“ R 722.0002 unistat 386w
40 1.5 M30x1,5 FL Yes Yes 600x700x1560 390 400;3~N;50 WATER 5 32 1/2“ R 554.0005 unistat 390w
35 1.5 M30x1,5 FL Yes Yes 600x700x1560 424 400;3~N;50 WATER 5 32 1/2“ R 553.0005 unistat 390w HT
57 1.3 M38x1,5 FL Yes Yes 920x1200x1655 995 400;3~;50 WATER 5 32 3/4“ R 558.0003 unistat 290w
80 2.5 M38x1,5 FL Yes Yes 920x1200x1655 991 400;3~;50 WATER 5 32 3/4“ R 705.0001 unistat 291w
100 2.5 1 1/4“ FL Yes Yes 1700x3500x1850 2100 400;3~;50 AIR 5 32 R 706.0001 unistat 292
100 2.5 1 1/4“ FL Yes Yes 2400x1200x1750 1950 400;3~;50 WATER 5 32 1“ R 706.0002 unistat 292w
18 0.7 M16x1 FL Yes Yes 700x800x1515 355 400;3~;50 WATER 5 32 1/2“ R 543.0004 unistat 420w
16 0.7 M16x1 FL Yes Yes 700x800x1515 390 400;3~;50 WATER 5 32 1/2“ R 541.0004 unistat 420w HT
44 1.5 M30x1,5 FL Yes Yes 920x1200x1655 685 400;3~;50 WATER 5 32 1/2“ R 707.0001 unistat 421w
FL Yes Yes 585x425x550 73 230;50 AIR 5 32 R 665.0004 CAL 1
FL Yes Yes 585x425x550 71 230;50 AIR 5 32 R 665.0005 CAL 2
FL Yes Yes 585x560x550 128 230;50 AIR 5 32 R 665.0003 CAL 3
FL Yes Yes 585x355x550 49 230;50 5 32 665.0006 CAL 4

12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50/60 AIR 5 32 R 466.0010 minichiller


12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50 WATER 5 32 1/2“ R 466.0020 minichiller w
12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50/60 AIR 5 32 O 466.0011 minichiller-1
12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50 WATER 5 32 1/2“ O 466.0021 minichiller w-1
18 0.5 M16x1 A NFL No Yes 277x500x425 37 230;50 AIR 5 32 O 576.0031 UC006A-1
22 3.0 M16x1 B No No 320x500x493 41 230;50 AIR 5 32 O 576.0050 UC007
22 3.0 M16x1 B NFL No Yes 320x500x493 41 230;50 AIR 5 32 O 576.0051 UC007-1
25 3.0 M16x1 B NFL No Yes 410x480x540 52 230;50 AIR 5 32 O 677.0021 UC015-1
25 3.0 M16x1 B NFL No Yes 410x480x540 53 230;50 WATER 5 32 1/2“ O 677.0031 UC015w-1
25 3.0 3/4“ B NFL No Yes 460x510x755 78 400;3~N;50 AIR 5 32 O 670.0031 UC022-1
25 3.0 3/4“ B NFL No Yes 460x510x755 93 400;3~N;50 WATER 5 32 1/2“ O 670.0041 UC022w-1
25 3.0 3/4“ B NFL No Yes 460x510x755 76 400;3~N;50 AIR 5 32 O 672.0031 UC020-1
25 3.0 3/4“ B NFL No Yes 460x510x755 73 400;3~N;50 WATER 5 32 1/2“ O 672.0041 UC020w-1
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request

www.huber-online.com · Tel. +49-781-96030 55


TECHNICAL DATA

g
in

xH

ty
ol

y
ty

la
t

ili
co
e

er

xD
ci

sp
ng

e n th

ab
ns
in

pa
er

W
Cooling Power at

Di
m wi
ge

Ra

t
ol

er

tI

S
at

Ca

g
Pa

of
co

ce e

e
e

in
um

la m

r
ur

g
Po

tu
en
e

ith

ith

in

sp olu

tio
t
gu

ra
ra

ill

Op
g

Vo
w

lu
tin

Di V

pe
pe

°C
el

lo

.F

C
in

in

so
h

th

th

°C
od

ta

00
m
m


a

in

C
t
Tm

Tm

He

Ba

Ba

Ba

Re
Ca

Te
Te

30

20

10

20


M

-2

-4

-6

-8

-1
m
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW
UC025-1 38 -10...40 0,8 0.1 0.5 2
UC025w-1 38 -10...40 0.8 0.1 0.5 2
UC006T-1 40 -25...40 1.25 0.1 0.5 0.45 0.07
UC009T-1 40 -25...40 1.25 0.1 0.5 0.7 0.25
UC012T-1 40 -25...40 1.25 0.1 0.5 1 0.4
UC016T-1 40 -10...40 2.5 0.1 0.5 0.9
UC020T-1 40 -20...40 2.5 0.1 0.5 2 0.5
UC025T-1 40 -10...40 2.5 0.1 0.5 1.2
UC040T-1 40 -10...40 2.1 0.1 0.5 2.2
UC045T-1 40 -20...40 2 0.1 0.5 4.3 1.5
UC055T-1 40 -10...40 5 0.1 0.5 3
UC060T-1 40 -20...40 5 0.1 0.5 6 1.5
UC080T-1 40 -10...40 5 0.1 0.5 4.8
UC100T-4 40 -20...40 8.36 0.1 0.5 10 2.5
UC110T-4 40 -10...40 8.36 0.1 0.5 6
UC130T-4 40 -10...40 8.36 0.1 0.5 7.2
UC150T-4 40 -20...40 17 0.1 0.5 15 3.7
UC160T-4 40 -10...40 17 0.1 0.5 8.8
UC200T-4 40 -10...40 17 0.1 0.5 11
UC210T-4 40 -20...40 17 0.1 0.5 21 5.2
UC250T-4 40 -10...40 20 0.1 0.5 14
UC260T-4 40 -20...40 20 0.1 0.5 26 5.2
UC300T-4 40 -10...40 25 0.1 0.5 16.5
UC400T-4 40 -10...40 25 0.1 0.5 22
UC006Tw-1 41 -20...40 1.25 0.1 0.5 0.45 0.25
UC009Tw-1 41 -25...40 1.25 0.1 0.5 0.7 0.2
UC012Tw-1 41 -25...40 1.25 0.1 0.5 1 0.3
UC015Tw-1 41 -25...40 1.55 0.1 0.5 1.2 0.4
UC023Tw-1 41 -25...40 1.55 0.1 0.5 1.6 0.5
UC016Tw-1 41 -10...40 2.5 0.1 0.5 0.9
UC020Tw-1 41 -20...40 2.5 0.1 0.5 2 0.5
UC025Tw-1 41 -10...40 2.5 0.1 0.5 1.2 0.1
UC030Tw-1 41 -20...40 2.5 0.1 0.5 3 1
UC040Tw-1 41 -10...40 2.5 0.1 0.5 2.1
UC055Tw-1 41 -10...40 5.9 0.1 0.5 4
UC060Tw-1 41 -20...40 5.9 0.1 0.5 6 1.4
UC080Tw-1 41 -10...40 5.9 0.1 0.5 4.65
UC100Tw-4 41 -20...40 6.5 0.1 0.5 10 3
UC110Tw-4 41 -10...40 6.5 0.1 0.5 5.8
UC130Tw-4 41 -10...40 6.5 0.1 0.5 7
UC150Tw-4 41 -20...40 11 0.1 0.5 15 5
UC160Tw-4 41 -10...40 11 0.1 0.5 9.5
UC200Tw-4 41 -10...40 11 0.1 0.5 10.7
UC210Tw-4 41 -20...40 12.3 0.1 0.5 21 10
UC250Tw-4 41 -10...40 12.3 0.1 0.5 13.6
UC260Tw-4 41 -20...40 12.3 0.1 0.5 26 12
UC300Tw-4 41 -10...40 12.3 0.1 0.5 16
UC400Tw-4 41 -10...40 18 0.1 0.5 21
UC500Tw-4 41 -10...40 25 0.1 0.5 26
Unichiller ETH-1 wl 42 -10...40 5.2 0.1 0.5 2
Rotacool 42 -20...40 1.5 0.1 1 0.3
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids

56 www.huber-online.com · Tel. +49-781-96030


TECHNICAL DATA

ne
p

p
um

um
p

tio io n

hi

re
p
m

an on
em ure
eP

ac
nP
um
Pu

tu
t
ec

i
nm

ct
t
ur

ra
io
P

ra
re

ot

*
e
n
ss

pe
ct
n

t*
io

pe
xH

nn
su

Pr
io
e

Su

at
Pr

em
n

Co
es

ct

an p

xD
re

er
io

er
m

te
-

rd
Su

tT
e-
Pr

tT
ri g
tu
te

sW
ct

er
Pu

rig
ro
da

ly

en
t

ra
Ra

en
Ra

ef
s-

s-

at
lP

pp

ef
nn

pe

on

fr

bi

W
bi
io
s

w
w

ve

su

lR
St
re

re

Co

go

m
m

si

m
lo

at
lo

o.
t
Le

.A

ra
.P

.P

te

er
gh
en

in

el
ty

.A
.F

ul
.F

lin
p

t.N
tu
er
fe

ol

od
m
ax

ax

ax
rc
x

ei
m
x

in
o
ma

Na
ma

Pu

Sa

Ov

Po

Co

Ca
Co
Lo

Di

W
Ci

M
m

m
l/min bar l/min bar mm kg V; Hz °C °C
25 3.0 3/4“ B NFL No Yes 460x615x755 88 400;3~N;50 AIR 5 32 O 674.0041 UC025-1
26.5 3.5 3/4“ B NFL No Yes 460x510x755 88 400;3~N;50 WATER 5 32 1/2“ O 674.0051 UC025w-1
30 0.7 M16x1 A NFL No No 350x310x615 40 230;50 AIR 5 32 O 582.0011 UC006T-1
30 0.7 M16x1 A NFL No No 350x310x615 41 230;50 AIR 5 32 O 584.0011 UC009T-1
30 0.7 M16x1 A NFL No No 350x310x615 44 230;50 AIR 5 32 O 586.0011 UC012T-1
22 3.0 1 1/4“ B NFL No Yes 450x510x1160 114 230;50 AIR 5 32 O 587.0011 UC016T-1
22 3.0 3/4“ B NFL No Yes 450x510x1160 130 230;50 AIR 5 32 O 588.0011 UC020T-1
22 3.0 3/4“ B NFL No Yes 450x510x1160 119 230;50 AIR 5 32 O 589.0011 UC025T-1
22 3.0 3/4“ B NFL No Yes 500x550x1265 110 400;3~N;50 AIR 5 32 O 590.0011 UC040T-1
22 3.0 3/4“ B NFL No Yes 500x550x1265 164 400;3~N;50 AIR 5 32 O 591.0011 UC045T-1
65 4.0 1 1/4“ C3 NFL No Yes 600x630x1600 175 400;3~N;50 AIR 5 32 O 592.0011 UC055T-1
65 4.0 1 1/4“ C3 NFL No Yes 600x630x1570 199 400;3~N;50 AIR 5 32 O 593.0011 UC060T-1
65 4.0 1 1/4“ C3 NFL No Yes 600x730x1570 223 400;3~N;50 AIR 5 32 O 594.0011 UC080T-1
65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 O 595.0006 UC100T-4
65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 R 596.0006 UC110T-4
65 4.0 1 1/4“ C3 NFL No Yes 874x1185x1870 480 400;3~N;50 AIR 5 32 R 597.0006 UC130T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1485x1870 480 400;3~N;50 AIR 5 32 R 598.0005 UC150T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1185x1870 235 400;3~N;50 AIR 5 32 R 600.0005 UC160T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1465x1870 480 400;3~N;50 AIR 5 32 R 601.0005 UC200T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 602.0005 UC210T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 603.0005 UC250T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 604.0005 UC260T-4
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 450 400;3~N;50 AIR 5 32 R 605.0005 UC300T-4
140 4.0 1 1/4“ D3 NFL No Yes 2500x1685x1800 480 400;3~N;50 AIR 5 32 R 650.0005 UC400T-4
30 0.7 M16x1 A NFL No Yes 230x280x550 30 230;50 WATER 5 40 1/2“ O 606.0031 UC006Tw-1
30 0.7 M16x1 A NFL No Yes 230x280x550 32 230;50 WATER 5 40 1/2“ O 607.0031 UC009Tw-1
30 0.7 M16x1 A NFL No Yes 350x310x615 40 230;50 WATER 5 40 1/2“ O 611.0011 UC012Tw-1
30 0.7 M16x1 A NFL No Yes 350x310x615 43 230;50 WATER 5 40 1/2“ O 613.0011 UC015Tw-1
30 0.7 M16x1 A NFL No Yes 350x310x615 50 230;50 WATER 5 40 1/2“ O 615.0011 UC023Tw-1
22 3.0 3/4“ B NFL No Yes 400x440x1100 96 230;50 WATER 5 40 1/2“ O 616.0011 UC016Tw-1
22 3.0 3/4“ B NFL No Yes 400x440x1100 109 230;50 WATER 5 40 1/2“ O 617.0011 UC020Tw-1
22 3.0 3/4“ B NFL No Yes 400x440x1100 97 230;50 WATER 5 40 1/2“ O 618.0011 UC025Tw-1
22 3.0 3/4“ B NFL No Yes 400x440x1100 115 400;3~N;50 WATER 5 40 1/2“ O 619.0011 UC030Tw-1
22 3.0 3/4“ B NFL No Yes 400x440x1100 110 400;3~N;50 WATER 5 40 1/2“ O 620.0011 UC040Tw-1
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 168 400;3~N;50 WATER 5 40 1/2“ O 621.0011 UC055Tw-1
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 173 400;3~N;50 WATER 5 40 1/2“ O 622.0011 UC060Tw-1
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 225 400;3~N;50 WATER 5 40 1/2“ O 623.0011 UC080Tw-1
90 5.5 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ O 624.0005 UC100Tw-4
65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ R 625.0005 UC110Tw-4
65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 370 400;3~N;50 WATER 5 40 1/2“ R 626.0005 UC130Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 370 400;3~N;50 WATER 5 40 1/2“ R 627.0005 UC150Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 600x600x1450 235 400;3~N;50 WATER 5 40 1/2“ R 628.0005 UC160Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 629.0005 UC200Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 1/2“ R 630.0007 UC210Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 631.0005 UC250Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 632.0005 UC260Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 450 400;3~N;50 WATER 5 40 3/4“ R 633.0005 UC300Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 480 400;3~N;50 WATER 5 40 3/4“ R 634.0005 UC400Tw-4
140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 520 400;3~N;50 WATER 5 40 1/2“ R 635.0005 UC500Tw-4
30 1.4 3/4“ Yes NFL No Yes 460x615x760 93 400;3~N;50 AIR+WATER 5 32 1/2“ R 673.0011 Unichiller ETH-1 wl
10 0.2 M16x1 Yes No Yes 470x580x420 32 230;50/60 AIR 5 32 O 659.0001 Rotacool
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request

www.huber-online.com · Tel. +49-781-96030 57


TECHNICAL DATA

g
in

xH

ty
ol

y
ty

la
t

ili
co
e

er

xD
ci

sp
ng

e n th

ab
ns
in

pa
er

W
Cooling Power at

Di
m wi
ge

Ra

t
ol

er

tI

S
at

Ca

g
Pa

of
co

ce e

e
e

in
um

la m

r
ur

g
Po

tu
en
e

ith

ith

in

sp olu

tio
t
gu

ra
ra

ill

Op
g

Vo
w

lu
tin

Di V

pe
pe

°C
el

lo

.F

C
in

in

so
h

th

th

°C
od

ta

00
m
m


a

in

C
t
Tm

Tm

He

Ba

Ba

Ba

Re
Ca

Te
Te

30

20

10

20


M

-2

-4

-6

-8

-1
m
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW
SPECIALS
Hotbox HB1-1 44 45...250 4.5 3.5 0.1
Hotbox HB2-1 44 60...250 6 3.5 0.1
Hotbox HB3-1 44 60...250 6 3.5 0.1
Hotbox HB4-1 44 25...250 12 3.5 0.1
Hotbox HB5-1 44 25...250 12 3.5 0.1
BFT1-2 44 0...80 2 22 8.5 280x280x150 0.1 0.02 1
BFT1w-2 44 0...80 2 22 280x280x150 0.1 0.02 1
BFT2-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5
BFT2w-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids

58 www.huber-online.com · Tel. +49-781-96030


TECHNICAL DATA

ne
p

p
um

um
p

tio io n

hi

re
p
m

an on
em ure
eP

ac
nP
um
Pu

tu
t
ec

i
nm

ct
t
ur

ra
io
P

ra
re

ot

*
e
n
ss

pe
ct
n

t*
io

pe
xH

nn
su

Pr
io
e

Su

at
Pr

em
n

Co
es

ct

an p

xD
re

er
io

er
m

te
-

rd
Su

tT
e-
Pr

tT
ri g
tu
te

sW
ct

er
Pu

rig
ro
da

ly

en
t

ra
Ra

en
Ra

ef
s-

s-

at
lP

pp

ef
nn

pe

on

fr

bi

W
bi
io
s

w
w

ve

su

lR
St
re

re

Co

go

m
m

si

m
lo

at
lo

o.
t
Le

.A

ra
.P

.P

te

er
gh
en

in

el
ty

.A
.F

ul
.F

lin
p

t.N
tu
er
fe

ol

od
m
ax

ax

ax
rc
x

ei
m
x

in
o
ma

Na
ma

Pu

Sa

Ov

Po

Co

Ca
Co
Lo

Di

W
Ci

M
m

m
l/min bar l/min bar mm kg V; Hz °C °C

M16x1 FL Yes Yes 180x430x360 19 400;3~N;50 5 32 290.0051 Hotbox HB1-1


M16x1 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0061 Hotbox HB2-1
80 1.6 M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0071 Hotbox HB3-1
M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0081 Hotbox HB4-1
M30x1,5 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0091 Hotbox HB5-1
FL Yes Yes 420x590x700 70 230;50 AIR 5 32 O 569.0005 BFT1-2
FL Yes Yes 420x590x700 70 230;50 WATER 5 32 1/2“ O 569.0006 BFT1w-2
FL Yes Yes 670x720x1070 116 400;3~N;50 AIR 5 32 O 249.0005 BFT2-2
FL Yes Yes 670x720x1070 116 400;3~N;50 WATER 5 32 1/2“ O 249.0006 BFT2w-2
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request

www.huber-online.com · Tel. +49-781-96030 59


GLOSSARY
A
Ambient Temperature ume with displacement insert, the upper lmmersion Thermostat
value the permissible maximum amount. is a thermostat that can be combined with
Range The difference is the so-called expansion a bath and to form a complete unit. Immer-
Ambient Temperature Range is the permis- volume. Especially in the case of external sion thermostats are equipped with a screw
sible temperature range of the environment applications, the size of the expansion tank clamp to attach them to any desired bath
in which the unit will function. lt is 5...32°C must be considered, since the circulating wall or can be fixed on a stand. Immersion
for all Huber units in this catalogue. The thermostat must also take up the expan- thermostats can also be fitted to a bridge
quoted cooling powers are for an ambient sion of the liquid in the external circuit. The and mounted permanently in a bath.
temperature of 20°C. smaller the surface area of the expansion
tank the lower is the area of thermofluid
open to attack from oxidation and air hu-

Automatic
midity absorption. Industrial Thermostats

C
Compressor Control (UC-Hx)
are refrigerated circulators (Unichiller
Is a procedure used in refrigeration ma- Calibration range) with factory fitted heating. The
chines to save energy. A microprocessor Thermostat (CAL) units have high cooling, heating and
control decides if the refrigeration machine is a bath thermostat with especially high pump powers which allow quick cool-
is required or if it can be switched off. temperature stability and especially con- ing and heating rates due to the small
sistent temperature distribution through internal volumes. They are ideal for
the bath. temperature control in process technol-
ogy, within a smaller temperature range
Automatic Cooling Capacity (-20..120°C).
Control Clear-view Thermostat
is a control routine to save energy. The mi- is a bath thermostat with transparent walls
croprocessor based controller determines for direct observation of the object being
whether it is possible to reduce the cooling thermoregulated. Interface, analogue
power. In addition to saving energy, this is used to input the set value or to output

D
also saves wear and tear of the compres- the actual value of temperature in analogue
sor, reduces the amount of heat discharged Discharge Pressure form, generally in the form of a current
into the environment, and gives better tem- is the positive pressure of the circulating (4...20 mA).
perature control. pump of a thermostat directly at the pump
discharge. lf only one value is given in the

B
tables, then this involves the maximum
delivery pressure for flow rate zero. Pump
Interface, digital
Bath/Circulation curves illustrate discharge in relation to the
is used to transfer data between connected
units in digital form via data cable. The set
Thermostat flow rate.
and actual temperature values are the main

E
is a thermostat with a bath opening which items transferred. The serial RS 232 inter-
is allows objects to be directly thermoregu- face allows a point-to-point connection.
lated in the bath as well as a pump (Com- Extended Working This means that at anyone time only two
patible Control thermostats have pressure Temperature Range participants such as the thermostat and the
and suction pump) for closed (pressure Extended Working Temperature Range is PC can communicate with each other via
pump) and open (suction and pressure the temperature range that can be attained the interface. The RS 485 interface is an
pumps) external circuits. when using a factory-fitted cooling coil addressable interface where up to 32 parti-
when operating with cooling water. cipants can be connected. Each participant

F
of the bus system has its address.

Bath Opening Flow Rate


is the usable surface that is available for
direct thermoregulation, as a rule over the
is the volume of liquid delivered per time
unit by the circulating pump measured with
Intrinsic Temperature
entire usable depth. is the operating temperature of a heating
water. If only one value is given in the table, thermostat that is reached when the heat-
this is the maximum flow rate for a zero ing is switched off. lt depends on the pump
discharge pressure. Pump curves illustrate power, thermofluid (viscosity and density)
discharge in relation to the flow rate.
Bath Thermostat used and the insulation of the thermostat,

H
is a thermostat which is equipped with a e.g. with or without a cover on the bath.
pump and a bath that contains the object
Heat Load

N
to be thermoregulated. The built-in circu-
is the maximum capacity of the installed
lating pump is used to mix the bath liquid,
but can also be used if necessary to cir-
electric heater. The heating is controlled Net Cooling Capacity
proportionally. The heating is continually is the effective capacity available in refrig-
culate the thermofluid through an exter-
controlled, and as the set point tempera- eration thermostats or circulating chillers.
nally connected circuit, e.g. connection of
ture is approached the power is reduced This is the net cooling power of the unit
a through-flow cooler to allow the cooling
automatically. after the frictional heat produced by the
of heating thermostats.
circulating pump and the heat entering as
a result of non-ideal insulation has been
Heating Thermostat subtracted.
Bath Volume is a thermostat whose working tempera-

O
ture range is primarily above the ambient
(also fill volume) temperature adds heat to the thermofluid.
Operating Temperature

I
is the volume of the bath liquid that is
required for adequate operation of the Range
thermostat, but without considering the lmmersion Cooler Operating Temperature Range is the tem-
volume of thermofluid in the external cir- is an additional chiller with a flexible tube perature range that is limited by the per-
cuit. lf two values are given, the lower and a cooling coil (evaporator) for immer- missible lowest and highest operating
value indicates the minimum required vol- sion cooling of any desired bath. temperatures.

60 www.huber-online.com · Tel. +49-781-96030


GLOSSARY
P
Pressure Pump thermostats and form a separate range of tables, then this involves the maximum
is used for circulation of the thermofluid in units in terms of their type of construction suction pressure for zero flow rate. Pump
an external closed circuit and in the bath. (DeskTop, Tower), the cooling and pump curves illustrate suction pressure in rela-
capacities. Generally they have no acces- tion to the flow rate.
sible bath. They are often used as a substi-

T
Pressure/Suction Pump tute for cooling with tap water. (exception:
This pump has a pressure and a suction minichiller)
stage which are driven by the same mo- Temperature Constance
tor. The thermofluid is delivered from the is half of the temperature difference be-
pressure stage from the thermostat into tween the highest and bowest tempera-
the circuit, and the suction stage draws Refrigerated/Heating tures which are measured for a specific set
point after attaining a stable value over a
the liquid back into the thermostat. A pres- Thermostat 30 minute period. The details are quoted for
sure/suction pump can be used in just the is a thermostat whose working tempera-
same way as a pressure pump for a closed 70°C (using water) for a heating thermostat
ture range is above and below the ambient
circuit. lt has the advantage compared to and at -10°C (using ethanol) for a cooling
temperature, and which can either add heat
a pressure pump that the pressure in the thermostat (see also DIN 12876).
to or extract heat from the bath liquid.
external circuit falls from positive values
(pressure) in the flow line and to negative
values (suction) in the return line and is al- Through-flow Coolers (DC)
most zero in the application itself. Thus it is Refrigerant are add-on coolers which are connected
suitable for the thermoregulation of pres- This is used in the refrigeration unit within into an external circuit to upgrade a heat-
sure-sensitive glass vessels. Additionally the thermostat and extracts the heat from ing thermostat to a heating/cooling ther-
it is possible to thermoregulate an open the thermoregulating liquid, when the mostat. They are used to replace water
external circuit (e.g. a bath) with the aid of compressed gas expands in the evapora- cooling, and also to extend the Iower op-
a pressure/suction pump. This cannot be tor. Huber has been completely CFC free erating temperature.
done with a pure pressure pump, since this since 1992 and HCFC (e.g. R22) free since

W
delivers thermofluid to the bath. The ther- 1994. Huber uses only refrigerants which
mofluid can only be returned to the bath do no damage to the ozone layer (ODP
via a suction stage. In any case a so-called Ozone Depletion Potential, ODP=0), and Working Temperature
constant Ievel device is required to main- minimal Global warming potential (GWP, Range
tain a constant level in the bath and this i.e. Green house effect). Working Temperature Range is the tem-
ensures that the flows of both pump stages perature range which can be attained at an
are controlled so that they are equal. This ambient temperature of 20°C by the ther-
is the only way that the Ievel in the external
bath can be maintained constant.
Refrigerated Thermostat mostat alone and with the exclusive use of
electrical energy. In the case of a heating
is a thermostat whose working tempera-
thermostat the working temperature be-
ture range is below the ambient tempera-
gins above room temperature (as a result
Process Control ture and draws heat from the thermofluid.
of the energy introduced by the pump and
Often cascade control, is when the tem- Huber refrigerated thermostats are strictly
the effective insulation) and ends at the up-
perature control is dictated by the tempera- speaking cooling/heating thermostats,
per limit of the operating temperature. The
ture of the connected external application. since their working temperature range is
WTR of a refrigeration thermostat begins
A temperature sensor (often a Pt100 4 wire above and below the ambient temperature.
with the lowest operating temperature of
configuration with a Lemosa plug) is there- Heat can be extracted from and added to
the unit and finishes with the upper tem-
fore required in the external application, the thermofluid.
perature at which the refrigeration machine
which is connected to the thermostat. The

S
can permanently operate.
actual value measured at the external ap-
plication is measured and a set point for Safety Classes
the thermostat is continually calculated. lt is possible to use non-flammable or flam-
Depending on the operating temperature, mable bath liquids with thermostats. The
insulation losses and exothermic reac- relevant safety requirements are given in
tions, the bath temperature and thus the DIN EN 61010-2-010. There is a distinction
flow temperature of the thermostat can be made between the NFL classes with built-in
considerably above or below the set point. over-heating protection that are exclusively
(Always consider the safety limits of the for non-flammable liquids and FL (Flam-
fluid!!) mable) with adjustable overtemperature

R
protection and bw level protection for flam-
Recirculation Thermostat mable liquids (all Huber thermostats).

(Unistats)
Is a thermostat in which thermofluid is
pumped through an open or closed exter- Standards
nal circuit. Recirculation thermostats e.g. The safety requirements for electrical
the Unistats can have a thermally discou- Iaboratory equipment, and especially also
pled expansion vessel, whose surface tem- those for thermostats, have been defined
perature is not the operating temperature. in European standards EN 61010-1 and EN
They do not have an accessible bath. Uni- 61010-2-01 0, replacement for DIN 12879,
stats have a thermally discoupled active among others. The terms and characteris-
surface (expansion vessel), where by the tic of characteristic data is defined in DIN
surface temperature is not necessarily the 12876-1 and DIN 12876-2.
same as the operating temperature.

Refrigerated Circulator Suction Pressure


is a special cooling thermostat which is de- is the negative pressure of the circulating
signed exclusively as a circulation thermo- pump of a thermostat directly at the pump
stat. Circulation chillers have evolved from suction. lf only one value is given in the

www.huber-online.com · Tel. +49-781-96030 61


GENERAL
Hotline Extract from the Sale or Return of Goods
Have you a thermoregulation prob- General Terms and If goods which have been dispat-
ched on a sale or return basis are
lem or questions relating to our Conditions not returned within the agreed
products? You can contact us Mon-
day to Friday from 7:30 to 18:00 period the goods are then consi-
(CET). Validity dered to be sold. If no return date
By placing the order the purchaser is issued, it is considered to be 4
Hotline: +49-781-9603-244 accepts the Sales, Delivery and weeks. The date is calculated from
Payment Terms of Peter Huber the date on the delivery note.
Kältemaschinenbau GmbH (www.
huber-online.com). The specific
delivery conditions are detailed in Retention of Title
the Confirmation of Order issued The delivered goods shall remain
by Huber. the property of the Peter Huber
Kältemaschinenbau GmbH until
all claims against the purchaser
3-2-1 Warranty Payment Terms arising from the business asso-
If pro forma payment has not been ciation have been settled.
on Registration agreed, invoices are all payable
within 30 days net, no discount.
Many years experience with mi- Redemption in acc. with WEEE /
nimal failures have allowed us to ElektroG (German law on electric
extend our warranty conditions. Delivery and electronic devices)
Since the 1.1.2000 we have ex- Delivery is always ex-works; we re- The sales prices are valid exclusive
tended our warranty on the refri- serve the right to supply the goods of the costs for the redemption and
geration system to 2 years. via a third party. disposal of old devices from users
other than private households.
If you register your unit serial Upon request, the supplier shall
number with us (in writing), you Transport / Transport Damage- also organize the redemption and
will receive the following warranty The transport of goods is always recycling/disposal of such devices
conditions: ordered by the purchaser. Should against compensation of the accru-
3 Years warranty on exchangeable loss or damage be incurred during eing costs, given such devices are
electronic controllers (Plug & Play), transport the purchaser must con- distributed by the supplier.
2 Years warranty on the refrige- tact the transport company and re-
ration technology (including com- quest that the goods are inspected
pressors) and 1 Year warranty on by a loss adjuster, in advance of an Validity of Contract
the mechanical and electrical com- insurance claim. If a clause of these conditions is
ponents. unworkable, the validity of the
other clauses is unaffected. If one
Please register your unit under Faults of the clauses has an unworkable
SERVICE at www.huber-online. The purchaser must check the section, the remainder of the clau-
com or by Fax +49-781-57211, goods immediately on receipt, if se will remain valid. The parties
the warranty period starts on the any problems are discovered de- involved are bound to agree a
dispatch date (ex works). Please tails should be forwarded to the replacement clause, with a similar
note that these extended warranty Peter Huber Kältemaschinenbau function.
conditions will not necessarily be GmbH within 5 days of receipt. If
adopted by our foreign service the complaint is upheld by Peter
partners. Please speak to our dis- Huber Kältemaschinenbau GmbH
tributors regarding the conditions the purchaser is entitled to claim
being offered. a repair or replacement part. The
purchaser can only claim dama-
ges, when he can prove that the
Peter Huber Kältemaschinenbau
GmbH has been grossly negligent.
We reserve the right to change Claims for loss of profit will not be
specification at any time. considered.
We accept no liability for print-
ing errors.

62 www.huber-online.com · Tel. +49-781-96030