Item Description Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelled and neatly dressed: All kinds of soil. Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5m. All kinds of soil. Banking excavated earth in layers not exceeding 20 cm. in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up; in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m. All kinds of soil. Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. Deduct for not watering the excavated earth for banking. Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m ; disposed earth to be levelled and neatly dressed. All kinds of soil Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm. on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : Ordinary rock Hard rock (requiring blasting) Hard rock (blasting prohibited) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil.

Unit

Rate

100 Sqm

2073.60

One Cubic Metre

157.55

One Cubic Metre One Cubic Metre One Cubic Metre

99.45 1.75 6.45

One Cubic Metre

101.85

One Cubic Metre One Cubic Metre One Cubic Metre

152.60 252.20 325.25

One Cubic Metre

103.40

02.009.01 02.009.02 02.009.03

Excavation work by mechanical means (Hydraulic excavator) manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m Ordinary rock One Cubic Metre Hard rock (requiring blasting) One Cubic Metre Hard rock (Blasting Prohibited) One Cubic Metre

162.65 272.95 332.45

Page 1

DSR_2007

Excavation trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. 02.010.01 One Metre 02.010.01.01 Pipes, cables etc, not exceeding 80 mm dia. 02.010.01.02 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. One Metre 02.010.01.03 Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600mm. One Metre Extra for excavating trenches for pipes, cables etc. in all kinds of soil 02.011 for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) One Metre Extra for excavating trenches for pipes, cables, etc, in all kinds of soil 02.012 for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) One Metre Excavating trenches of required width for pipes, cables, etc, including 02.013 excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Ordinary rock : 02.013.01 One Metre 02.013.01.01 Pipes, cables etc. not exceeding 80 mm dia. 02.013.01.02 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. One Metre 02.013.01.03 Pipes, cables exceeding 300 mm dia.but not exceeding 600mm dia. One Metre Hard rock (requiring blasting) 02.013.02 One Metre 02.013.02.01 Pipes, cables etc. not exceeding 80 mm dia. 02.013.02.02 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. One Metre 02.013.02.03 Pipes, cables etc. exceeding 300 mm dia.but not exeeding 600mm dia. One Metre Hard rock (blasting prohibited) 02.013.03 One Metre 02.013.03.01 Pipes, cables etc. not exceeding 80 mm dia. 02.013.03.02 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. One Metre 02.013.03.03 Pipes, cables etc. exceeding 300 mm dia.but not exceeding 600mm dia. One Metre 02.014 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) One Metre 02.015 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3 m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) One Metre Close timbering in trenches including strutting, shoring and packing 02.016 cavities (wherever required) complete. (Measurements to be taken of the face area timbered) : Depth not exceeiding 1.5 m. One Square Metre 02.016.01 02.010

70.45 115.05 179.65

133%

340%

100.20 248.10 285.50 152.75 378.20 435.25 180.85 447.85 515.35

104%

259%

69.80

Page 2

DSR_2007

02.016.02 02.016.03 02.017

02.017.01 02.017.02 02.017.03 02.018

02.018.01 02.018.02 02.018.03 02.019

Depth exceeding 1.5 m but not exceeding 3 m. Depth exceeding 3 m but not exceeding 4.5 m Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timebered): Depth not exceeding 1.5 m. Depth exceeding 1.5 m but not exceeding 3 m Depth exceeding 3 m but not exceeding 4.5 m Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete.(Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m. Depth exceeding 1.5 m but not exceeding 3 m. Depth exceeding 3m but not exceeding 4.5 m. Extra for planking, strutting and packing materials for cavities ( in close timbering ) if required to be left permanently in position (Face area of timber permanently left to be measured) Open timbering the trenches including strutting and shoring complete (Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m. Depth exceeding 1.5 m but not exceeding 3 m. Depth exceeding 3 m but not exceeding 4.5 m. Open timbering in case of shafts, wells, cesspits, manholes and the like including strutting and shoring complete (measurements to be taken of the face area timbered): Depth not exceeding 1.5 m. Depth exceeding 1.5 m but not exceeding 3 m. Depth exceeding 3 m but not exceeding 4.5 m. Open timbering over areas including strutting, shoring etc. complete. (Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m. Depth exceeding 1.5 m but not exceeding 3 m. Depth exceeding 3 m but not exceeding 4.5 m. Extra for planking and strutting in open timbering if required to be left permanently in position (face area of the timber permanently left to be measured). Extra rate for quantities of works, executed : In or under water and/or liquid mud, including pumping out water as required. In or under foul position, including pumping out water as required. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. Extra for every additional lift of 1.5 m or part thereof in: All kinds of soil. Ordinary or hard rock. Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete.

One Square Metre One Square Metre

72.20 77.60

One Square Metre One Square Metre One Square Metre

71.60 76.70 82.00

One Square Metre One Square Metre One Square Metre

62.40 65.15 68.15

One Square Metre

923.05

02.020 02.020.01 02.020.02 02.020.03 02.021

One Square Metre One Square Metre One Square Metre

35.20 36.70 39.10

02.021.01 02.021.02 02.021.03 02.022

One Square Metre One Square Metre One Square Metre

30.40 32.75 35.80

02.022.01 02.022.02 02.022.03 02.023

One Square Metre One Square Metre One Square Metre

21.50 23.20 25.80

One Square Metre

463.85

02.024 02.024.01 02.024.02

mtr.depth mtr.depth

20% 25%

02.025

One Cubic Metre One Cubic Metre One Cubic Metre

45.70 18.90 33.85

02.026 02.026.01 02.026.02 02.027

One Cubic Metre

301.50

Page 3

DSR_2007

02.028

02.028.01 02.029 02.029.01 02.030

Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m: All kinds of soil. 100 sqm. Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same: All kinds of soil. 100 sqm

512.10

512.40

Excavating holes upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc. disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5 m: All kinds of soil. Each 54.30 02.030.01 Ordinary rock. 02.030.02 Each 82.85 Hard rock (requiring blasting) Each 152.10 02.030.03 Hard rock (blasting prohibited) Each 181.85 02.030.04 Cleaning jungle including uprooting of rank vegetation, grass, brush 02.031 wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. One Hundred Square Metre 263.90 Clearing grass and removal of the rubbish upto a distance of 50 m 02.032 outside the periphery of the area cleared. One Hyndred Square Metre 135.65 Felling trees of the girth (measured at a height of 1 m above ground 02.033 level) including cutting of trunks and branches removing the roots and stacking of serviceable materials and disposal of unserviceable material Beyond 30 cm girth upto and including 60 cm girth Each 81.70 02.033.01 Beyond 60 cm girth upto and including 120 cm girth Each 359.80 02.033.02 Beyond 120 cm girth upto and including 240 cm girth Each 1658.85 02.033.03 Above 240 cm girth Each 3330.20 02.033.04 Supplying chemical emulsion in sealed containers including delivery 02.034 as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% litre 174.30 02.034.01 Diluting and injecting chemical emulsion for POST02.035 CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along external wall where the apron is not provided using chemical 02.035.01 emulsion @ 7.5 litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete: One Metre 6.75 02.035.01.01 W ith chlorpyriphos/Lindane E.C. 20% with 1% concentration. Along the external wall below concrete or masonry apron using 02.035.02 chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. One Metre 10.45 02.035.02.01 W ith chlorpyriphos/Lindane E.C. 20% with 1% concentration. Treatment of soil under existing floors using chemical emulsion @ 02.035.03 one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand ) to match the existing floor. One Square Metre 48.70 02.035.03.01 W ith Chlorpyriphos/Lindane E.C. 20% with 1% concentration. Treatment of existing masonry using chemical emulsion @ one litre 02.035.04 per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 ( 1 cement :2 coarse sand) to the full depth of the hole.

Page 4

DSR_2007

02.035.04.01 W ith Chlorpyriphos/Lindane E.C. 20% with 1% concentration. Treatment at points of contact of wood work by chemical emulsion 02.035.05 chlorpyriphos. (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. Deduct for disposed soil not levelled and neatly dressed (against Item 02.036 No. 2.6 & 2.7). Cement mortar 1:1 ( 1 cement : 1 fine sand ) 03.001 Cement mortar 1:2 ( 1 cement : 2 fine sand ) 03.002 Cement mortar 1:3 ( 1 cement : 3 fine sand ) 03.003 Cement mortar 1:4 ( 1 cement : 4 fine sand ) 03.004 Cement mortar 1:5 ( 1 cement : 5 fine sand ) 03.005 Cement mortar 1:6 ( 1 cement : 6 fine sand ) 03.006 Cement mortar 1:2 ( 1 cement : 2 coarse sand ) 03.007 Cement mortar 1:3 ( 1 cement : 3 coarse sand ) 03.008 Cement mortar 1:4 ( 1 cement : 4 coarse sand ) 03.009 Cement mortar 1:5 ( 1 cement : 5 coarse sand ) 03.010 Cement mortar 1:6 ( 1 cement : 6 coarse sand ) 03.011 Cement mortar 1:2 ( 1 cement : 2 stone dust ) 03.012 Cement mortar 1 : 2 ( 1 cement : 2 marble dust ) 03.013 Cement mortar 1:5 ( 1 cement : 5 marble dust ) 03.014 W hite cement mortar 1:2 ( 1 W hite cement : 2 marble dust ) 03.015 W hite cement mortar 1:3 ( 1 W hite cement : 3 Marble dust) 03.016 W hite cement mortar 1:5 ( 1 white cement : 5 marble dust ) 03.017 Mud Mortar 03.018 Providing and laying in position cement concrete of specified grade 04.001 excluding the cost of centring and shuttering - All work upto plinth level. 1:1:2 ( 1 cement : 2 coarse sand : 2 graded stone aggregate 20 mm 04.001.01 nominal size ) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 04.001.02 mm nominal size ) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm 04.001.03 nominal size) 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm 04.001.04 nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm 04.001.05 nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm 04.001.06 nominal size ) 1:3:6 ( 1 cement : 3 fine sand : 6 graded stone aggregate 40 mm 04.001.07 nominal size ) 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm 04.001.08 nominal size ) 1:4:8 ( 1 cement : 4 fine sand : 8 graded stone aggregate 40 mm 04.001.09 nominal size ) 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 04.001.10 mm nominal size ) 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm 04.001.11 nominal size ) 1: 2: 3.5 :9 (1 ordinary Portland cement : 2.5 Fly Ash:3.5 Coarse 04.001.12 Sand : 9 Graded Stone Aggregate 40mm nominal size). 1: 2.5: 4: 11 (1 ordinary Portland Cement : 2.5 Fly Ash: 4 Coarse 04.001.13 Sand: 11 Graded Stone Aggregate 40mm nominal size).

One Metre

7.60

One Metre One One One One One One One One One One One One One One One One One One One Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Cubic Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

79.80 91.25 5055.70 3598.25 2870.00 2278.85 1960.55 1687.70 3864.25 3169.60 2578.45 2260.15 1987.30 3959.25 4054.25 2474.15 7590.25 6035.60 4086.15 156.85

One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre

4738.95 3629.80 3257.45 3194.10 2791.05 2713.05 2560.20 2449.00 2296.15 2237.75 2079.60 2388.45 2154.45

Page 5

DSR_2007

04.002

04.002.01 04.002.02 04.002.03 04.002.04 04.002.05 04.002.06

Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor five level, excluding the cost of centring, shuttering and finishing. 1:1:2 (1 Cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size ) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size )

One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre

5060.60 3951.45 3579.10 3515.75 3112.70

04.002.07 04.003 04.003.01 04.003.02

One Cubic Metre 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) One Cubic Metre Centring and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of columns. One Square Metre Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets etc. Columns, piers, abutments, pillars, posts and struts. Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centring, shuttering and finishing. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) Providing and fixing upto floor five level precast cement concrete string or lacing courses, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand ), cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand )on exposed surfaces complete. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand ) including the cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces complete. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

3034.70 2881.85

119.25

04.003.03 04.004

One Square Metre One Square Metre

180.40 238.40

04.004.01 04.004.02 04.005

One Cubic Metre One Cubic Metre

3257.45 2791.05

04.005.01 04.005.02 04.006

One Cubic Metre One Cubic Metre

4814.35 4347.95

04.006.01

One Cubic Metre

4115.15

Page 6

DSR_2007

04.007 Providing and fixing upto floor five level precast cement concrete solid block including hoisting and setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand ), cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces complete. 1:2:4 ) 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) Providing and fixing upto floor five level precast cement concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand ), cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces complete. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size )

04.007.01 04.007.02 04.008

One Cubic Metre One Cubic Metre

5561.90 5095.50

04.008.01 04.008.02 04.009

One Cubic Metre One Cubic Metre

4840.40 4625.80

04.010

04.011

Precasting and Placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. pipe 40 mm dia and 450 mm long with 150 x 150 x 6 mm M.S. plate welded at bottom and embeded 150 mm in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including necessary excavation of size 250 x 250 x 450 mm deep for the same in bitumen/concrete pavement at specified spacing. Each Providing and laying damp-proof Course 40 mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ) One Square Metre Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) One Square Metre Extra for providing and mixing water proofing material 'Impermo' or equivalent in cement concrete work @ 1 Kg. per 50 Kg. of cement. Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per square mdtre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Extra for concrete work in superstructure above floor V level for each four floors or part thereof. Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. Extra for laying concrete in or under foul positions. Making Plinth Protection 50mm thick of cement concrete 13:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level.

324.70

144.15

178.05

04.012 per bag of 50 kg. of cement used in the mix 27.45

04.013

One Square Metre One Cubic Metre

58.60 235.65

04.014 04.015

04.016 04.017

per cum per metre depth. 180.75 One Cubic Metre 69.65

One Square Metre

222.65

05.001

Page 7

DSR_2007

05.001.01 05.001.02 05.001.03 05.002

05.002.01 05.002.02 05.002.03 05.003

1:1:2 ( 1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size ) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. Upto floor five level excluding cost of centring, shuttering, finishing and reinforcement. 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size ) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement Providing and laying upto floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15 degree upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). Reinforced cement concrete work in chmineys, shafts upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). Reinforced cement concrete work in well-steining excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). Reinforced cement concrete work in Vertical and Horizontal fins individually or forming box louvers, facias and eaves boards upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ). Centring and shuttering including strutting, propping etc. and removal of form for :

One Cubic Metre One Cubic Metre One Cubic Metre

4841.15 3732.00 3359.60

One Cubic Metre One Cubic Metre One Cubic Metre

5201.50 4092.35 3720.00

One Cubic Metre

3673.85

05.004

One Cubic Metre

3502.85

05.005

One Cubic Metre

3545.90

05.006

One Cubic Metre

3760.85

05.007

One Cubic Metre

3270.00

05.008

One Cubic Metre

3928.75

05.009

05.009.01 05.009.02 05.009.03 05.009.04 05.009.05

Foundations, footings, bases of columns etc. for mass concrete. One Square Metre W alls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. One Square Metre Suspended floors, roofs, landings, balconies and access platforms Shelves (Cast-in-situ) Lintels, beams, plinth beams, girders, bressumers and cantilevers. One Square Metre One Square Metre One Square Metre

119.25 180.40 187.35 187.35 162.65

Page 8

DSR_2007

Columns, Pillars, Piers, Abutments, Posts and Struts. Stairs, (excluding landings) except spiral-staircases. Spiral staircases (including landing) Arches, domes, vaults upto 6 m span. Extra for arches, domes, vaults exceeding 6 m span. Chimneys and shafts W ell steining Vertical and horizontal finds individually or forming box louvers band, facias and eaves boards Extra for shuttering in circular work (20% of respective centring and 05.009.14 shuttering items) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, 05.009.15 window sills, string courses, bands, copings bed plates, anchor blocks and the like. Edges of slabs and breaks in floors and walls. 05.009.16 05.009.16.01 Under 20 cms wide 05.009.16.02 Above 20 cm wide Cornics and mouldings 05.009.17 Small surfaces such as cantilever ends, brackets and ends of steps, 05.009.18 caps and bases to pilasters and columns and the like. W eather shade, Chajjas, corbels etc., including edges. 05.009.19 Suspended floors, roofs, landings, balconies and access platform 05.009.20 with water proof py 12mm thick. Lintels, beams, plinth beams, girders, bressumers and cantilevers 05.009.21 with water proof ply 12mm thick Providing and fixing tie bolt, spring coil and plastic cone in wall 05.010 shuttering complete as per the direction of engineer-in-charge. 12 mm dia & 100 mm length 05.010.01 12 mm dia & 150 mm length 05.010.02 20 mm dia & 150 mm length 05.010.03 20 mm dia & 225 mm length 05.010.04 Extra for additional height in centring, shuttering where ever required 05.011 with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to 05.011.01 be measured). 05.012 Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centring, shuttering, finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand )on exposed surfaces complete but excluding cost of reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) Providing, hoisting and fixing upto floor five level precast reinforced 05.013 cement concrete in small lintels not exceeding 1.5m clear span upto floor five level including the cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). 05.009.06 05.009.07 05.009.08 05.009.09 05.009.10 05.009.11 05.009.12 05.009.13

One One One One One One One

Square Square Square Square Square Square Square

Metre Metre Metre Metre Metre Metre Metre

238.40 204.00 182.70 514.70 259.60 180.40 326.50 285.55 20%

One Square Metre One Square Metre

One Square Metre One Metre One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

119.25 61.10 278.25 323.00 246.95 258.60 329.80 319.10

Each Each Each Each

Set Set Set Set

89.00 101.80 119.20 136.60

One Square Metre

106.20

One Cubic Metre

4882.25

One Cubic Metre

6002.80

Page 9

DSR_2007

05.014

Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc. including setting in cement mortar 1:3 (1 cement : 3 coarse sand )cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). One Cubic Metre Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in lintels, beams and bressumers including setting in cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centring and shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). One Cubic Metre

6725.35

05.015

5243.25

05.016 Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand ), cost of required centring, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ). 05.017 Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in vertical & horizontal fins individually or forming box louvers setting in cement mortar 1:2 ( 1 cement : 2 coarse sand ) including the cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 ( 1 cement : 3 fine sand ) on exposed surfaces complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ). Providing, precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 6 mm nominal size ) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine sand ) etc. complete excluding plastering of the jambs, sills and soffits. 50 mm thick 40 mm thick 25 mm thick Encasing rolled steel sections, in beams and columns, with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 stone aggregate 12.5 mm nominal size ) including centring and shuttering complete but excluding cost of reinforcement. Encasing rolled steel section in grillages with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size ) including centring and shuttering but excluding cost of expanded metal and hangers. Extra for providing and fixing expanded metal mesh of size 20 x 60 mm and strands 3.25 mm wide 1.6 mm thick weighing 3.64 kg. per sqm. for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Mild steel and medium tensile steel bars

One Cubic Metre

6840.10

One Cubic Metre

6745.50

05.018

05.018.01 05.018.02 05.018.03 05.019

One Square Metre One Square Metre One Square Metre

359.20 304.05 277.35

One Cubic Metre

5045.95

05.020

One Cubic Metre

3448.90

05.021

One Square Metre

255.40

05.022 05.022.01

One Kilogram

41.50

Page 10

DSR_2007

05.022.02 05.022.03 05.022.04 05.022.05 05.022.06 05.023

05.024

05.025 05.026 05.027

Hard drawn steel wire Cold twisted bars Hot rolled deformed bars Hard drawn steel wire fabric Thermo-Mechanically Treated bars. Add or deduct for omitting in R.C.C. work smooth finishing of the exposed surface with 6 mm thick cement mortar 1:3 ( 1 cement : 3 fine sand ) Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement : 2 coarse sand ) including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landings and steps including subsequent removal and cleaning of the same. Providing and fixing in position copper plate as per design for expansion joints. Providing and filling in position, blown bitumen in expansion joints. Providing and filling in position bitumen mix filler of Proportion 80 kg. of hot bitumen, 1 kg. of cement and 0.25 cubicmetre of coarse sand for expansion joints. Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS:1838 including cost of primer, sealing compound in expansion joints. Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatment. Non-asbestos fibre cement board 6mm thick as per IS 14862. 150 mm wide 200 mm wide Aluminium fluted strips 3.15 mm thick 150 mm wide. 200 mm wide. Add or deduct for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. Extra for laying reinforced cement concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.

One One One One One

Kilogram Kilogram Kilogram Kilogram Kilogram

41.50 42.70 42.70 52.00 42.70

One Square Metre

62.15

One Square Metre One Kilogram

47.40 231.05

per cm. depth per cm. width per 100 m. 348.70

per cm depth per cm width per 100 m. 98.85

05.028

per cm depth per 100 m. 334.55

05.029

05.029.01 05.029.01.01 05.029.01.02 05.029.02 05.029.02.01 05.029.02.02 05.030 05.031

One Metre One Metre One Metre One Metre One Metre

69.90 93.80 276.80 368.40 11.95

per cum per metre depth. 180.75 69.65

05.032 Extra for laying reinforced cement concrete in or under foul positions. One Cubic Metre 05.033 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement including Admixtures in recommended proportions (as per IS 9103) to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-charge -M-25 grade reinforced cement concrete by using 410kg,. Of cementper cum of concrete. All work upto floor V level. . One Cubic Metre Add or deduct for providing richer or leaner mixes respectively at all floor levels. Providing M-30 grade concrete by using 420kg of cement per cum of concrete instead of M-25 grade B.M.C. / R.M.C. One Cubic Metre

4147.40

05.034 05.034.01

54.55

Page 11

DSR_2007

05.034.02 05.034.03 05.035 05.036

Providing M-35 grade concrete by using 428kg of cement per cum of concrete instead of M-25 grade B.M.C. / R.M.C. One Cubic Metre Providing M-40 grade concrete by using 435kg of cement per cum of concrete instead of M-25 grade B.M.C / R.M.C. One Cubic Metre Deduct for using less cement than the quantity as provided in the item of batch mix concrete / RMC as arrived as per mix design. Quintal Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in 1:1 1/2:3 ( 1 cement : 1 1/2 coarse sand : 3 graded stone aggregate 10 mm nominal size ) including flush or deep ruled pointing at joints in cement mortar 1:2 ( 1 cement : 2 fine sand ), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, form work in precasting, handling, hoisting, centring and erection complete for all floor levels but excluding the cost of reinforcement. One Cubic Metre

98.20 136.40 528.15

9683.15

05.037 Providing and laying in position ready mixed concrete manufactured in fully authomatic batchingplant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design f specified grade for reinforced cement concrete work incuding pumping of R.M.C., from transit mixer to site of laying excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. M-25 grade Reinforced cement concrete by using 410kg of cement per cum of concrete. All works upto floor V level. Extra for RCC / BMC / RMC work above floor V level for each four floors or part thereof . Extra for carriage of RMC beyond the initial lead of 10 km. Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in : Cement mortar 1:4 ( 1 cement : 4 coarse sand ) Cement mortar 1:6 (1 cement : 6 coarse sand ) Brick work with Modular bricks of class designation 75 in foundation and plinth in : Cement mortar 1:4 ( 1 cement : 4 coarse sand ) Cement Mortar 1:6 (One Cement : 6 coarse Sand ). Brick work with machine moulded perforated bricks of class designation 125 conforming to IS 2222 - 1991 in superstructure above plinth level upto floor level in cement mortar 1:6 (1 cement : 6 Coarse sand) W ith FPS bricks W ith Modular Bricks Brick work with F.P.S. bricks of class designation 75 in superstructure iabove plinth level upto floor V level in all shapes and sizes in : Cement Mortar 1:4 (1 cement : 4 coarse sand) Cement mortar 1:6 (1 cement : 6 coarse sand) Extra for brick work in Superstructure above floor V level for each four floors or part thereof by mechanical means by lifting material using mobile crane.

One Cubic Metre One Cubic Metre One Cubic Metre

4356.50 92.90 20.90

05.038 05.039 06.001 06.001.01 06.001.02 06.002 06.002.01 06.002.02 06.003

One Cubic Metre One Cubic Metre

2293.40 2121.75

One Cubic Metre One Cubic Metre

2200.25 2049.20

06.003.01 06.003.02 06.004

One Cubic Metre One Cubic Metre

3195.10 3001.25

06.004.01 06.004.02 06.005

One Cubic Metre One Cubic Metre

2601.90 2430.25

One Cubic Metre

190.00

Page 12

DSR_2007

06.006

06.007

06.008 06.009

Extra for forming cavity 5 cm to 7.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M.S. ties 300 mm long of 25 mm x 3 mm section at not less than 3 ties per sqm as per approved design. Providing half brick masonry with FPS bricks of class designation 75 in cement mortar 1:3 ( 1 cement : 3 coarse sand ) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm/11.4 cm wide bitumen felt type 3 grade 1. Brick work 7 cm thick with FPS bricks of class designation 75 in cement mortar 1:3 ( 1 cement :3 coarse sand ) in superstructure. Brick work in plain arches in superstructure including centring and shuttering complete for span upto 6 metres with bricks of class designation 75 in cement mortar 1:3 ( 1 cement : 3 coarse sand )

One Square Metre

47.35

One Metre One Square Metre

89.50 214.85

One Cubic Metre

3847.45

06.010 Brick work in gauged arches in superstructure in cement mortar 1:3 ( 1 cement : 3 coarse sand ) including centring and shuttering complete, for span upto 6 metres with bricks of class designation 75: Extra for additional cost of centring for arches exceeding 6 m span including all shuttering, bolting, wedging and removal (Area of the soffit to be measured). Half brick masonry with FPS bricks of class designation 75 in foundations and plinth in: Cement mortar 1:3 ( 1 cement : 3 coarse sand ) Cement mortar 1:4 ( 1 cement : 4 coarse sand ) Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto floor V level.: Cement mortar 1:3 ( 1 cement : 3 coarse sand ) Cement mortar 1:4 (1 cement : 4 coarse sand) Extra for half brick masonry in Superstructure, above floor V level for every four floors or part thereof by mechanical mans by lifting material using mobile crane. . Extra for providing and placing in position 2 Nos. 6mm dia M.S.bars at every third course of half brick masonry ( with FPS bricks ). Tile brick masonry with tile bricks of class designation 100 in foundation and plinth in : Cement mortar 1:4 ( 1 cement : 4 coarse sand ) Cement mortar 1:6 ( 1 cement : 6 coarse sand ) Tile brick masonry with machine moulded tile bricks of class designation 125 conforming to IS : 2690 (Part-1) - 1993 in foundation and plinth in cement mortar 1:6 ( 1 cement : 6 coarse sand ). Tile brick masonry with tile bricks of class designation 100 in superstructure above plinth level upto floor V level in cement mortar 1:6 ( 1 cement : 6 coarse sand ) Extra for tile brick masonry with tile bricks of class designation 100 in superstructure above floor five level for every four floors or part thereof. Tile brick masonry with tile bricks of class designation 100 in plain arch work in superstructure in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including centering and shuttering complete.

One Cubic Metre

4490.65

06.011

One Square Metre

259.60

06.012 06.012.01 06.012.02 06.013 06.013.01 06.013.02 06.014

One Square Metre One Square Metre

289.60 270.35

One Square Metre One Square Metre

322.00 302.80

One Square Metre

16.85

06.015 One Sapare Metre One Cubic Metre One Cubic Metre One Cubic Metre 47.80

06.016 06.016.01 06.016.02 06.017

3552.30 3277.65

One Cubic Metre

3969.85

06.018

One Cubic Metre

3603.35

06.019

One Cubic Metre

235.65

06.020

One Cubic Metre

4876.55.

Page 13

DSR_2007

06.021 Tile brick masonry with tile bricks of class designation 100 in gauged arch work in superstructure in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including centering and shuttering complete. Tile brick masonry work 5cm thick with tile bricks of class designation 100 in cement mortar 1:3 ( 1 cement : 3 coarse sand ) in Superstructure. Honey-comb brick work 10/11.4 cm thick with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ). Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc., complete. Extra for laying brick work in or under foul position. Brick work with selected FPS bricks of class designation 75 in exposd brick work including marking horizontal and vertica grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand). Brick work with modular bricks of class designation 75 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand).

One Cubic Metre

5484.40

06.022

One Cubic Metre One Square Metre

212.10 203.55

06.023 06.024

06.025 06.026

One Cubic Metre One Cubic Metre

180.75 69.65

One Cubic Metre

2165.60

06.027

One Square Metre

2065.10

06.028 Brick work with machine moulded modular bricks of class designation 125 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand) One Cubicd Metre 06.029 Brick work with machine moulded FPS bricks of class designation 125 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand ). Brick work with machine moulded perforated FPS bricks of class designation 125 conforming IS: 2222-1991 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand). Brick work with machine moulded perforated modular bricks of class designation 125 conforming to IS : 2222-1991 in exposed brick work including makinghorizontal and vertical grooves 10mm wide 12mm deep complete from ground level upto plinth level in cement mortar 1:6 (1cement : 6 coarse sand). Brick work with clay flyash FPS brick of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1:4 (1 cement : 4 coarse sand ) Cement mortar 1:6 ( 1 cement : 6 coarse sand )

2432.75

One Cubic Metre

2635.10

06.030

One Cubic Metre

2902.45

06.031

One Cubic Metre

2715.60

06.032 06.032.01 06.032.02 06.033

One Cubic Metre One Cubic Metre

2306.35 2134.70

06.034

06.034.01 06.034.02

Extra for Exposed brick work / clay flyash brick work in superstructure above floor five level, for each four floors or part thereof. One Cubic Metre Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 100 average compressive strength in super structure above plinth level upto floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand) One Cubic Metre Cement mortar 1:6 (1 cement : 6 coarse sand). One Cubic Metre

235.65

2434.35 2283.30

Page 14

DSR_2007

06.035

06.035.01 06.035.02 06.036 06.036.01 06.037

Brick work with modular calcium silicate bricks machine moulded conforming to IS 4139-1989, class designation 100 average compressive strength in super structure above plinth level upto floor V level in : Cement Mortar 1:4 ( 1 cement : 4 coarse sand ) Cement Mortar 1:6 ( 1 cement : 6 coarse sand ) Brick work with modular extruded burnt fly ash clay sewer bricks (conforming to IS 4885-1988) in arches in foundation and plnth Cement Mortar 1:4 ( 1cement : 4 coarse sand ) Brick work with modular extruded burnt fly ash clay sewer bricks (conforming to IS: 4885-1988) in arches in foundation and plinth in cement mortar 1:3 (1cement : 3 fine sand ).

One Cubic Metre. One Cubic Metre One Cubic Metre

3164.60 3013.55

One Cubic Metre

3048.75

One Cubic Metre

4550.30

06.038 Providing and laying autoclaved aerated cement blocks masonry with 100mm thick AAC blocks in super structure above plinth level upto floor V level in cement mortar 1:4 (1cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos. 6mm dia MS bars at every third course of masonry work. One Cubic Metre Extra for AAC block masonry in superstructure above floor V level for every four floors or part there of : One Cubic Metre Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level upto floor V level, Gypsum blocks witl have a minimum compressive strength of 9.3 kg/sqcm. Extra for Gypsum panel partitions in superstructure above floor V level for every four floors or part thereof : Brick work with mechanized autoclaved flyash lime bricks conforming to IS: 12894 : 2002 of class designation 100 in superstructure above plinth level upto floor V level in : Cement mortar 1:4 ( 1cement : 4coarse sand) Cement mortar 1:6 ( 1cement : 6 coarse sand ) Extra for mechanized autoclave flyash lime bricks conforming to IS: 12894-1990 of class designation 100 in superstructure above floor V level for each four floors or part thereof. Brick edging 7cm wide 11.4cm deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at plinth level with : Cement mortar 1:6 ( 1 cement : 6 coarse sand ) Extra for random rubble masonry with hard stone in superstructure ,above plinth level and upto floor five level including levelling up with cement concrete 1:6:12 ( 1 cement :6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) at window sills, ceiling level and the like. Extra for random rubble masonry with hard stone in superstructure above floor V level for every four floors or part thereof. Extra for random rubble masonry with hard stone in : Square or rectangular pillars Circular pillars.

3348.40 235.65

06.039 06.040

One Square Metre One Square Metre

803.10 27.20

06.041 06.042

06.042.01 06.042.02 06.043

One Cubic Metre One Cubic Metre

2465.55 2293.90

One Cubic Metre

235.65

06.044

One Metre

16.25

07.001

07.001.01 07.002

One Cubic Metre

1838.90

One Cubic Metre

372.35

07.003 One Cubic Metre One Cubic Metre One Cubic Metre 314.20 137.80 421.45

07.004 07.004.01 07.004.02

Page 15

DSR_2007

07.005 07.006 07.006.01 07.007 07.007.01 07.008 07.009

07.010 07.010.01 07.010.02 07.011 07.012

07.012.01 07.012.01.01 07.012.01.02 07.012.02. 07.012.02.01 07.012.02.02 07.013

07.013.01 07.013.02 07.014

07.014.01 07.014.02 07.015

07.015.01 07.015.01.01 07.015.01.02 07.015.02 07.015.02.01 07.015.02.02 07.016 07.017 07.017.01

Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 ( 1 cement : 6 coarse sand ) Coursed rubble masony (second sort)with hard stone in foundation and plinth with : Cement mortar 1:6 ( 1 cement : 6 coarse sand ) Extra for Coursed Rubble Masonary with hard stone (first sort) in superstructure above pinth level and upto floor five level. Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor V level for every four floors or part thereof.. Extra for coursed rubble masonry with hard stone (first or second sort) in :. Square or rectangular pillars.. Circular pillars. Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6m. Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 ( 1 cement : 6 coarse sand ) including pointing with cement mortar 1:2 ( 1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. One face dressed Red sand stone. W hite sand stone. Both face dressed. Red sand stone. W hite sand stone. Stone work plain ashlar in arches in cement mortar 1:3 ( 1 cement : 3 coarse sand ) including centring, shuttering and pointing with white cement mortar 1:2 ( 1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone W hite Sand stone. Stone work plain ashlar in domes in cement mortar 1:3 ( 1 cement : 3 coarse sand ) including centring, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone W hite sand stone. Stone work ashlar punched (ordinary) in superstructure upto floor five level in cement mortar 1:6 ( 1 white cement : 6 coarse sand ) including pointing with cement mortar 1:2 ( 1 cement : 2 stone dust )with an admixture of pigment matching the stone shade. Red sand stone: One face punched. Double faced punched. W hite sand stone. Single face punched Double face punched. Extra for stone work, plain ashlar or ashlar punched above floor V level for every four floors or part thereof. Extra for plain ashlar or ashlar punched in : Square or rectangular pillars.

One Cubic Metre

173.50

One Cubic Metre

2022.70

One Cubic Metre One Cubic Metre

1913.10 361.50

One Cubic Metre

314.20

One Cubic Metre One Cubic Metre One Cubic Metre

152.60 476.30 187.95

One Cubic Metre One Cubic Metre One Cubic Metre

14154.00 14929.00 17450.00 18225.00

One Cubic Metre One Cubic Metre

16424.00 17199.00

One Cubic Metre One Cubic Metre

23248.00 24024.00

One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre. One Cubic Metre One Cubic Metre

13677.00 16497.00 14451.00 17272.00 314.00 1042.00

Page 16

DSR_2007

07.018 07.019

07.020

07.020.01 07.020.02 07.021 07.021.01 07.021.02 07.022 07.023

Extra for stone work; plain ashlar or ashlar punched curved on plan with a mean radius not exceeding 6 m. Extra for additional cost of centring for arches exceeding 6 m span including all strutting, bolting, wedging etc. and removal (area of soffit to be measured). Stone work sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : : 6 coarse sand ) including pointing with white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade. Red sand stone W hite sand stone Extra for stone work sunk or moulded or sunk and moulded or carved in: Triangular or Square or rectangular pillars. Circular or polygonal pillars. Extra for stone work sunk or moulded in cornices. Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade: (To be secured to the backing by means of cramps which shall be paid for seperately) Red sand stone - exposed face fine dressed with rough backing. 70 mm thick 60 mm thick 50 mm thick 40 mm thick 30mm thick Red sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick 60 mm thick 50 mm thick 40mm thick 30mm thick W hite sand stone - expoed fae fine dressed with rough backing 70mm thick 60mm thick 50mm thick 40mm thick 30mm thick W hite sand stone - exposed face machine cut and table rubbed with rough backing. 70mm thick 60mm thick 50mm thick 40mm thick 30mm thick Extra for stone work (veneer work)curved on plan with a mean radius not exceeding 6 m. Providing and fixing stainless steel metal cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1 cement : 2 fine sand ) including making the necessary chases in stone and holes in walls wherever required..

One Cubic Metre

724.00

One Square Metre

259.60

One Cubic Metre One Cubic Metre

18430.00 19204.00

One Cubic Metre 1359.00 One Cubic Metre 3850.00 per metre per cm. girth. 8.90

07.023.01 07.023.01.01 07.023.01.02 07.023.01.03 07.023.01.04 07.023.01.05 07.023.02. 07.023.02.01 07.023.02.02 07.023.02.03 07.023.02.04 07.023.02.05 07.023.03 07.023.03.01 07.023.03.02 07.023.03.03 07.023.03.04 07.023.03.05 07.023.04 07.023.04.01 07.023.04.02 07.023.04.03 07.023.04.04 07.023.04.05 07.024 07.025 One One One One One Square Square Square Square Square Metre Metre Metre Metre Metre 1251.75 1180.35 1109.15 1037.60 966.20

One One One One One One One One One One

Square Square Square Square Square Square Square Square Square Square

Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

1568.20 1496.85 1425.65 1354.10 1282.70 1305.95 1226.85 1147.90 1068.45 989.45

One One One One One

Square Square Square Square Square

Metre Metre Metre Metre Metre

1622.45 1543.30 1464.40 1412.80 1305.90 1042.00

One Cubic Metre

One kilogram

529.50

Page 17

DSR_2007

07.026

Providing and fixing stone dowels 10x5x2.50 cm cut to double wedge shape as per design in cement mortar 1:2 ( 1 cement : 2 fine sand ) including making the necessary chases. Each

21.25

07.027 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1 cement : 2 fine sand ) including making the necessary chases. Providing and fixing sloping chajja of stone 40 mm thick and upto 80 07.028 cm wide beyond the wall as measured along the slope in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with 12 mm diameter anchoring steel bar 45 cm long fixed in each stone and supported on and including with bricks cove of class designation 75 in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including pointing in cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade: Red sand stone 07.028.01 07.028.01.01 W ith F.P.S. Bricks W hite sand stone : 07.028.02 07.028.02.01 W ith F.P.S. bricks 07.029 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including pointing in white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade: Red sand stone 07.029.01 W hite sand stone 07.029.02 30 mm red sand stone sun-shade (chisel-dressed) supported on red 07.030 sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand ) including finishing complete. Providing and fixing red sand stone brackets 55x22.5x45 cm sunk 07.031 and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6 mm. 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. Stone work, plain in copings, cornices, string courses and plinth 07.032 courses upto 75mm thick in cement mortar 1:6 ( 1 cement : 6 coarse sand ) including pointing with white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade. Red sand stone 07.032.01 W hite sand stone 07.032.02 Providing and fixing stone jali 40 mm thick throughout in cement 07.033 mortar 1:3 ( 1 cement : 3 coarse sand ) including pointing in white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 07.033.01 W hite sand stone 07.033.02 Extra for laying stone work in or under water and/ or liquid mud 07.034 including cost of pumping or bailing out water and removing slush etc., complete. Extra for laying stone work in or under foul position. 07.035

Each

20.00

One Square Metre One Square Med`e

643.70 675.60

One Square Metre One Square Metre

395.30 423.15

One Square Metre

418.50

Each

1346.80

One Cubic Metre One Cubic Metre

18406.00 19181.00

One Square Metre One Square Metre

3668.80 3694.40

One Cubic Metre per Metre depth 180.75 One Cubic Metre 69.65

Page 18

DSR_2007

W all lining butch work upto 10m height with Dholpur stone 40mm thick rough facing on the exposed surface with stone strips of minimum length 300mm and required width including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75mm and by providing layer of 75mm thick strips including 12mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand) including ruled pointing in cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-incharge. Stone work (machine cut edges) for wall lining upto 10m height 07.037 etc.(veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1cement : 3 coarse sand) and jointed with cement mortar 1:2 (1cement : 2 stone dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately ). Kota stone slabs exposed face dressed and rubbed. 07.037.01 07.037.01.01 25mm thick Stone tile work for wall lining upto 10m height with special adhessive 07.038 over 12mm thick bed of cement mortar 1:3 (1cement : 3 coarsesand) including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) 07.038.01 07.038.01.01 Granite stone of any colour and shade 07.038.01.02 Raj Nagar plain white marble / Udaipur green marble / Zebra black marble. Extra for stone work for wall lining on exterior walls of height more 07.039 than 10m from ground level for every additional height of 3m or part thereof. 07.040 Providing and fixing dry cladding upto 10metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx 1m, fixed to structural steel frame work and / or with the help of cramps, pins etc., and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge . (The steel frame work, stainless steel cramps and pins etc., shall be paid for separately). Red sand stone 07.040.01 W hite sand stone 07.040.02 07.036

One Square Metre

802.15

One Square Metre

724.95

One Square Metre One Square Metre One Square Metre 1043.75 894.95

One Square Metre

40.75

One Square Metre

1323.40 1382.35

Page 19

DSR_2007

07.041 Providing and fixing structural steel frame (for dry cladding with 30mm thick gang saw cut with machine cut edges sand stone) on walls of all heights using MS square / rectangular tube in the required pattern as per architectural drawing including cost of cutting, bending, welding etc., The frame work shall be supported in wall with the help of MS brackets / lugs of angle iron / flats etc. whcich shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) of size 300x230x300mm including cost of necessary centring andshuttering and with approved expansionhold fasteners on CC/RCC surface including drilling necessary holes. Approved cramps / pins etc., shall be welded to the frame work to support stone cladding the steel work will be given a priming coat of zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid ). One Kilogram 07.042 Providing and fixing adjustable stainless steel cramps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame work at suitable location including making necessary recesses in stone slab, drilling required holes etc., complete as per direction of the Engineer-in-charge. each 08.001 Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in cement mortar 1:3 (1 W hite cement : 3 coarse sand ) including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust ) with an admixture of pigment to match the marble shade : (To be secured to the backing by means of cramps, which shall be paid for separately) Raj Nagar Plain W hite Marble / Udaipur green marble / Zebra black 08.001.01 marble. One Square 08.001.01.01 Area of slab upto 0.50 sqm. One Square 08.001.01.02 Area of slab over 0.50 sqm. 08.002 Providing and fixing 18 mm thick gang saw cut mirror polished premoulded and prepolished ), machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand )with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc., complete at all levels. Rajnagar plain white marble / Udaipur green marble / Zebra black 08.002.01 marble. One Square 08.002.01.01 Area of slab upto 0.50 sqm. One Square 08.002.01.02 Area of slab over 0.50 sqm. Granite of any colour and shade One Square 08.002.02 One Square 08.002.02.01 Area of slab upto 0.5 sqm One Square 08.002.02.02 Area of slab over 0.50 sqm.

80.75

272.50

Metre Metre

1511.60 1562.50

Metre Metre Metre Metre Metre

1309.40 1358.15 2480.20 2543.65

Page 20

DSR_2007

08.003 Extra for edge moulding to 18mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-charge. Marble work Granite work Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin based adhesive including cleaning etc., complete. 08.005 Extra for providing opening of required size & shape for wash basins / kitchen sink in kitchen platform, vanity counters and similar location in marble / granite / stone work including necessary holes for pillar taps etc., including rubbing and polishing of cut edges etc., complete. Mirror polishing on marble work / granite work / stone work where ever rquired to give high gloss finish complete. Providing and fixing cramps of required size & shape in RCC / CC backing with cement mortar 1:2 ( 1cement : 2 coarse sand ) including drilling necessary hole in stones and embedding the cramp in the hole ( fastener to be paid separately ) Gunmetal cramps. Stainless steel cramps Providing and fixing expansion hold fasteners on CC / RCC surface backing incuding drilling necessary holes and the cost of bolt etc., complete. W edge expansion type Fastener with threaded dia 6mm Fastener with threaded dia 10mm Fastener with threaded dia 12mm Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8 mm thick Raj nagar plain white marble / Udaipur green marble / Zebra black marble. Granite of any colour and shade. Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.80 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size ) as per direction of Engineer-in-charge and finished smooth. W hite Agaria Marble Stone Granite Stone of approved shade. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Second class teak wood Sal wood Kiln seasoned and chemically treated Hollock wood. Providing laminated veneer lumber conforming to IS: 14616 and TAD15:2001 (Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position as per directions of Engineer-in-charge.

08.003.01 08.003.02 08.004

One Metre One Metre

57.90 97.60

One Square Metre

106.80

each One Square Metre

151.00 94.20

08.006 08.007

08.007.01 08.007.02 08.008

One Kilogram One Kilogramme

500.65 529.50

08.008.01 08.008.01.01 08.008.01.02 08.008.01.03 08.009

each each each

16.40 805.55 18.95 32.00

08.009.01 08.009.01.01 08.009.01.02 08.010

One Square Metre One Square Metre

805.55 1116.30

08.010.01 08.010.02 09.001 09.001.01 09.001.02 09.001.03 09.002

One Square Metre One Square Metre

2274.45 2595.00

One Cubic Metre One Cubic Metre One Cubic Metre

52090.00 30511.95 31339.45

One Cubic Metre

69044.20

Page 21

DSR_2007

09.003 09.003.01 09.003.02 09.004 09.004.01 09.004.02 09.004.03 09.005

09.005.01 09.005.01.01 09.005.01.02 09.005.02 09.005.02.01 09.005.02.02 09.005.13.02 09.005.13.03

09.005.13.04 09.006

09.006.01

09.006.02

Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : Second class deodar wood Kiln seasoned and chemically treated Hollock wood. Extra for additional labour for circular work such as in frames of fan light. Second class teak wood. Sal wood Kiln seasoned and chemically treated Hollock wood. Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked black enamelled MS Butt hinges with necessary screws excluding, penelling which will be paid for separately. Second class teak wood 35 mm thhick shutters 30mm thick shutters Kiln seasoned and chemically treated Hollock wood. 35 mm thick shutters. 30 mm thick shutters Veneered particle board with commercial veneering on both sides conforming to IS:3097 Prelaminated particle board with decorative lamination on one side and balancing lamination on other side, grade I, Type II conforming to IS:12823. Prelaminated particle board with decorative lamination on both sides, Grade I, Type II conforming to IS:12823. Providing and fixing 35mm thick factory made laminated veneer lumber door shutter conforming to IS:14616 and TADS 15:2001(Part B) including ISI marked black enamelled MS butt hinges with necessary screws as per directions of Engineer-in-charge and panelling with panels of : 12mm thick plain grade -1, medium density flat pressed three layer particle board FPT-1 or graded wood particle board FPT- 1 IS: 3087 marked bonded with BW P type synthetic resin adhessive as per IS: 848. 12mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT-1 or graded wood particle board FPT-1, conforming to IS:3087 bonded with BW P type synthetic resin adhessive as per IS: 848 and pre-laminated conforming to IS: 12823 Grade-1, Type-II marked.

One Cubic Metre One Cubic Metre

29107.80 29777.30

One Cubic Metre One Cubic Metre One Cubic Metre

5208.90 3051.40 3134.15

One Square Metre One Square Metre

1373.65 1219.10 899.70 810.90 595.10

One Square Metre

One Square Metre One Square Metre

790.10 896.20

One Square Metre

1877.20

One Square Metre

2014.25

09.006.03 12mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade-1 medium density flat pressed, three layer particle board FPT-1 or graded wood particle board FPT-1 conforming to IS:3087 bonded with BW P type synthetic resin adhessive as per IS: 848 and prelaminated conforming to IS: 12823 Grade-1, Type-II marked. One Square Metre 09.007 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portioninside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. Second class teak wood Kiln seasoned and chemically treated Hollock wood

1960.80

09.007.01 09.007.02

One Square Metre One Square Metre

1075.60 711.25

Page 22

DSR_2007

Ply wood 5 ply, 9mm thick : 09.007.03 09.007.03.01 Decorative plywood both side decorative veneer (Type-I) conforming to IS: 1328 BW R type. 09.007.03.02 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-I) conforming to IS: 1328 BW R type. Ply wood 7 ply, 9mm thick : 09.007.04 09.007.04.01 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-I) conforming to IS: 1328 BW R type. Particle Board 12mm thick 09.007.05 09.007.05.01 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 09.007.05.02 Veneered flat pressed three layr or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 09.007.05.03 Pre-laminated particle board with decorative lamination on one sde and balancing lamination on other side, Grade I, Type-II IS: 12823 marked. 09.007.05.04 Pre-laminated particle board with decorative lamination on both sides, Grade-I, Type-II, IS: 12823 marked. 09.008 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts ecluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. Coir veneer board (conforming to IS:14842-2000) 12 mm thick Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked MS butt hinges with necessary screws. Second class teak wood 35mm thick 30mm thick Kiln seasoned and chemically treated Hollock wood 35mm thick 30mm thick

One Square Metre

1121.60

One Square Metre

923.30

One Square Metre

971.85

One Square Metre

518.35

One Square Metre

740.20

One Square Metre One Square Metre

985.70 1027.30

09.008.01 09.009

One Square Metre

920.50

09.009.01 09.009.01.01 09.009.01.02 09.009.02 09.009.02.01 09.009.02.02 09.010

One Square Metre One Square Metre One Square Metre One Square Metre

1718.30 1541.65 1178.60 1077.05

09.010.01 09.011

09.011.01 09.012

Providing and fixing factory mad laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part-B), using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked black enamelled MS butt hinges with necessary screws as per direction of Engineer-in-charge. 30mm thick shutters One Square Metre Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 5.5 mm thick instead of 4mm thick. One Square Metre Extra for provilding frosted glass panes 4mm thick instead of oridnary glass panes 4mm thick in doors, windows and clerestory window shutters.(Area of spening for glass panes excluding portion inside rebate shall be measured) One Square metre

1633.25

106.85

10.45

Page 23

DSR_2007

09.013 Deduct for providing pin headed glass panes instead of ordinary glass panes weighing 10 kg/sqm ( 4 mm thick ) in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). One Square Metre Extra for providing ISI marked Stainless Steel butt hinges instead of black enamelled M.S. butt hinges with necessary screws. (Shutter area to be measured). One Square Metre Deduct if fixed shutters (without hinges) area provided instead of openable shutters for doors, windows or clerestory windows with : Stainless Steel butt hinges with Stainless Steel screws: One Square Metre 112.00

102.20

09.014

83.80

09.015

09.015.01 09.015.01.01

For 2nd class teak wood and other inferior class of wood shutters. Black enamelled MS butt hinges with necessary screws. 09.015.02 09.015.02.01 For 2nd class teak wood and other inferior class of wood shutters. Providing and fixing 25 mm thick shutters for cup board etc. 09.016 Panelled or panelled & glazed shutters: 09.016.01 09.016.01.01 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Glazed shutters : 09.016.02 09.016.02.01 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Providing and fixing flat pressed 3 layer particle board medium 09.017 density exterior grade (Grade I) or graded wood particle board IS:3087 marked to frame, backing or studding with screws etc., complete (Frames, backing or studding to be paid separately). 12 mm thick 09.017.01 18 mm thick 09.017.02 Providing and fixing prelaminated flat pressed 3 layer (medium 09.018 density)particle board or graded wood particle board IIS:3087 marked with one side decorative and other side balancing lamination Grade I. Type II exterior grade IS :12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethene primer (fittings to be paid separately). 18 mm thick 09.018.01 25 mm thick 09.018.02 09.019 Providing and fixing 25 mm thick shutters for cupboards etc. including ISI marked black enamelled M.S. butt hinges with necessary screws: Panelled or panelled and glazed shutters. 09.019.01 09.019.01.01 Second class teak wood Glazed shutters 09.019.02 09.019.02.01 Second class teak wood Providing and fixing ISI marked flush door shutters conforming to 09.020 IS:2202 (Part - 1 ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI masrked Stainless Steel butt hinges with 09.020.01 necessary screws. 30 mm thick including ISI marked Stainless Steel butt hinges with 09.020.02 necessary screws.

One Square Metre

28.80

One Square Metre

1372.50

One Square Metre

1368.90

One Square Metre One Square Metre

364.95 418.40

One Square Metre One Square Metre

935.95 1009.70

One Square Metre One Square Metre

1312.95 1387.10

One Square Metre One Square Metre

1473.50 1415.45

Page 24

DSR_2007

09.020.03 25 mm thick (for cupboard) including ISI marked nickle plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part-1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. One Square Metre 1317.65

09.021

09.021.01 09.021.02 09.021.03 09.022

One Square Metre One Square Metre One Square Metre

929.95 904.40 853.05

Extra for Providing and fixing flush doors with decorative veneering On one side in item no.9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters ( over all area of door shutter to be measured) Over item no.9.20 and 9.21. 09.023.02.01 Second class teak wood Extra for providing vision panel not exceeding 0.1 sqm in all type of 09.024 flush doors (Cost of glass excluded) (overall area of door shutter to be measured). Rectangular or square 09.024.01 Circular. 09.024.02 Extra if louvers ( not exceeding 0.2 sqm) are provided in flush door 09.025 shutters (overall area of door shutters to be measured) Decorative type door. 09.025.01 Extra for cutting rebate in flush door shutters (Total area of the 09.026 shutter to be measured). Providing and fixing 35 mm thick wire gauge shutters using 09.027 galvanised M.S. wire gauge of average width of aperture 1.4 mm with wire of dia 0.63 mm for doors, windows and clerestory windows including ISI marked bright finished or / and black enamelled MS butt hinges with necessary screws: Second class teak wood. 09.027.01 Kiln seasoned and chemically treated Hollock wood. 09.027.02 Providing and fixing 35 mm thick wire gauze shutters using 09.028 galvanised M.S. wire gauze of average width of aperture 1.4 mm with wire of dia 0.63 mm for doors, windows and clerestory windows including ISI marked stainless steel . butt hinges with necessary screws: Second class teak wood. 09.028.01 Kiln seasoned and chemically treated Hollock wood. 09.028.02 09.029 Providing and fixing 30mm thick wire gauge shutters using galvanised MS wire gauge of average width of aperture 1.4mm with wire of dia. 0.63mm for doors, windows and clerestory windows including ISI marked Stainless Steel butt hinges with necessary screws : Second class teak wood. 09.029.01 Kiln seasoned and chemically treated Hollock wood. 09.029.02 09.022.01 09.023

One Square Metre

261.35

One Square Metre One Square Metre

284.55 1063.20

One Square Metre One Square Metre

99.90 137.05

One Square Metre One Square Metre

243.90 66.20

One Square Metre One Square Metre

1548.90 1071.10

One Square Metre One Square Metre

1632.70 1154.90

One Square Metre One Square Metre

1422.15 1013.85

Page 25

DSR_2007

09.030

09.030.01 09.030.02 09.031

Providing and fixing 30 mm thick wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4 mm with wire of dia 0.63 mm for doors, windows and clerestory windows including ISI marked bright finished or / and black enamelled M.S. but hinges with necessary screws : Second class teak wood. One Square Metre Kiln seasoned and chemically treated Hollock wood. One Square Metre Providing and fixingwire gauze laminated veneer lumber shutters conforming to IS: 14616, and as per TADS 15:2001 (Part B) using galvanised wire gauze with average width of aperture 1.4mm in both directions with wire of dia 0.63mm as per IS: 1568 for doors, windows and clerestory windows including ISI marked bright finished or / and black enamelled M.S. butt hinges with necessary screws as per directions of Engineer-in-charge. 35mm thick shutters. 30 mm thick shutters. Providing 50x50x50 mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 ( 1 cement : 3 fine sand ) and making good the walls etc. Each Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised MS screws including drilling holes in masonry work / CC / RCC and making good etc., complete. 25mm long 32 mm long 40 mm long 50 mm long Providing and fixing 2nd class teak wood plain lining tongued and grooved on and including wooden plugs complete with necessary screws and priming coat on unexposed surface. 40mm thick 25mm thick 12mm thick 12 mm thick Providing and fixing in wall lining flat pressed three layer (medium density) particle board ) or graded wood ) prelaminated one side decorative lamination on other side balancing lamination grade I, Type II conforming to IS 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete. 12 mm thick 18 mm thick 25 mm thick Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Hollock wood. Providing and fixing plywood 4mm thick one side decorative veneer conforming to IS: 1328 (type-I) for plain lining / cladding with necessary screws, priming coat on unexposed surface with : Decorative veneer facings of approved manufacture. Providing and fixing 4mm thick coir veneer board,, ISI marked IS:14842 - 2000, plain lining with necessary screws, priming coat on unexposed surface etc., complete.

1365.70 957.50

09.031.01 09.031.02 09.032

1677.40 1470.65

10.15

09.033

09.033.01 09.033.02 09.033.03 09.033.04 09.034

One One One One

Square Square Square Square

Metre Metre Metre Metre

9.40 11.15 13.45 15.80

09.034.01 09.034.02 09.034.03 09.034.4 09.035

One One One One

Square Square Square Square

Metre Metre Metre Metre

2649.20 1708.95 1360.95 867.70

09.035.01 09.035.02 09.035.03 09.036

One Square Metre One Square Metre One Square Metre

869.70 1024.30 1099.65

09.036.01 09.037

One Cubic Metre

54377.30

09.037.01 09.038

One Square Metre.

577.40

One Square Metre

556.50

Page 26

DSR_2007

09.039 Providing and fixing skirting of Pre-laminated with (one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II conforming to IS:12823, marked with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete. 18 mm thick 25 mm thick Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 2nd class teak wood 50 x 12 mm 50x 20 mm Hollock wood 50 x 12 mm 50 x 20 mm Providing and fixing plain jaffri of 35 x 10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50 x 12 mm beading complete with : Second class teak wood. Providing and fixing 18mm thick, 150mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS: 3087 marked including top cover of 6mm commercial ply wood conforming to IS: 303 BW R grade, nickel plated MS pipe 20mm dia. ( Heavy type ) curtain rod with nickel plated brackets including fixing with 25x3mm MS flat 10cm long and rawl plugs 50mm long (designation 10 no.) etc., all complete. Providing and fixing 18mm thick, 150mm wide pelmet of coir veneer board ISI marked IS: 14842 - 2000, including top cover of 6mm coir veneer board, nickel plated MS pipe 20mm dia. ( Heavy type ) curtain rod with nickel plated brackets including fixing with 25x3mm MS flat 10cm long and rawl plugs 50mm long (designation 10 no.) etc., all complete. Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. Non decorative veneer on both sides. Partricle board with decorative veneering on both sides. Providing and fixing teak wood lipping of size 25x3mm in pelmet. Providing and fixing cutain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete. 12 mm dia. 20 mm dia. 25 mm dia. Providing and fixing nickel plated MS pipe curtain rods with nickel plated brackets : 20mm dia. ( heavy type ) 25mm dia ( heavy type ) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding Fixed to openings / wooden frames with rawl plugs screws etc.

09.039.01 09.039.02 09.040

One Square Metre One Square Metre

1150.35 1225.70

09.040.01 09.040.01.01 09.040.01.02 09.040.02 09.040.02.01 09.040.02.02 09.041

One Metre One Metre One Metre One Metre

53.85 75.10 40.05 52.10

09.041.01 09.042

One Square Metre

890.00

One Metre.

208.70

09.043

One Metre

309.20

09.044 09.044.01 09.044.02 09.045 09.046

One Metre One Metre

18.95 68.00 26.60

09.046.01 09.046.02 09.046.03 09.047 09.047.01 09.047.02 09.048

One Metre One Metre One Metre

163.40 187.80 299.30

Each Each

69.90 76.85

09.048.01 09.048.02

One Kilogram One Kilogram

59.25 64.40

Page 27

DSR_2007

09.049

09.050

09.051

09.051.01 09.051.02 09.052

09.053

Providing and fixing expanded metal 20x60mm strands 3.25mm wide and 1.6mm thhick for windows etc., including 62x19mm beading of IInd class teak wood. One Square Providing and fixing hard drawn steel wire fabric 75 x 25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including 62 x 19 mm beading of second class teak wood. One Square Providing and fixing fly proof galvanised M.S. wire gauze to windows and clerestory windows using galvanised M.S. wire gauze with average width of aperture 1.4 mm in both directions with wire of dia.0.63 mm. W ith 2nd class teak wood beading 62x19 mm One Square W ith 12 mm mild steel U beading. One Square Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. One Square Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Each Providing beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with: Sal wood. Hollock wood Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws wtc. complete : 125 x 65 x 2.12 mm 100 x 58 x 1.90 mm 75x47x1.70 mm 50 X 37 X 1.50 mm Providing and fixing IS:1341 marked M.S. heavy weight - Butt Hinges with necessary screws etc. complete. 125 x 90 x 4.00 mm 100 x 75 x 3.50 mm 75 x 60 x 3.10 mm 50 x 40 x 2.50 mm. Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 125 x 65 x 2.12 mm 100 x 58 x 1.90 mm 75 x 47 x 1.70 mm 50 x 37 x 1.50 mm Providing and fixing ISI marked oxidised M.S. pressed parliamentary hinges with necessary screws etc. complete: 150 x 125 x 27 x 2.80 mm 125 x 125 x 27 x 2.80 mm 100 x 125 x 27 x 2.80 mm 75 x 100 x 20 x 2.24 mm Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete: 150 mm 125 mm 100 mm

Metre.

523.15

Metre

657.95

Metre Metre

443.80 291.95

Metre

72.00

61.50

09.054

09.054.01 09.054.02 09.055 09.055.01 09.055.02 09.055.03 09.055.04 09.056 09.056.01 09.056.02 09.056.03 09.056.04 09.057 09.057.01 09.057.02 09.057.03 09.057.04 09.058 09.058.01 09.058.02 09.058.03 09.058.04 09.059 09.059.01 09.059.02 09.059.03

One Cubic Metre One Cubic Metre

28335.90 28217.40

Each Each Each Each

16.80 13.10 9.55 5.35

Each Each Each Each

37.50 22.25 13.40 8.15

Each Each Each Each

18.55 13.45 9.30 5.25

Each Each Each Each

37.70 31.90 27.25 20.65

Each Each Each

96.20 90.40 72.55

Page 28

DSR_2007

09.060 09.060.01 09.060.02 09.060.03 09.061 09.061.01 09.061.02 09.061.03 09.062 09.062.01 09.062.02 09.063 09.063.01 09.063.02 09.063.03 09.063.04 09.064

09.065 09.065.01 09.065.02 09.066 09.066.01 09.066.02 09.066.03 09.067 09.067.01 09.067.02 09.067.03 09.068 09.068.01 09.068.02 09.068.03 09.069 09.070 09.070.01 09.070.02 09.070.03 09.070.04 09.071

Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 150 mm 125 mm. 100 mm Providing M.S. Piano hinges ISI marked IS 3818 finished with nickel plating and fixing with necessary screws etc. complete. Overall width 35 mm Overall width 50 mm Overall width 65 mm Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete. 300 x 16 mm 250 x 16 mm Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250 x 10 mm 200 x 10 mm 150 x 10 mm 100 x 10 mm Providing and fixing ISI marked 85 mm x 42 mm oxidised M.S. pull bolt lock conforming to IS:7534 with necessary screws bolts, nut and washers etc. complete. Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete: 300 x 20 x 6 mm 250 x 20 x 6 mm Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm 100 mm 75 mm Providing and fixing oxidised M.S. hasp and staple (Safety type ) conforming to IS:363 with necessary screws etc. complete : 150 mm 115 mm 90 mm Providing and fixing oxidized M.S. casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 gms. 250 mm weighing not less than 150 gms. 200 mm weighing not less than 120 gms. Providing and fixing Oxidised MS Safety chain with necessary fixtures for doors (weighing not less than 450 gms.) Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges with Stainless Steel screws etc. complete. 125 x 64 x 1.90 mm. 100 x 58 x 1.90 mm. 75 x 47 x 1.80 mm. 50 x 37 x 1.50 mm. Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete). 125 x 64 x 2.50 mm. 100 x 60 x 2.50 mm. 75 x 50 x 2.50 mm

each Each each

98.55 86.95 67.90

One Metre One Metre One Metre

72.35 78.20 84.00

Each Each

79.60 69.65

Each Each Each Each

33.90 28.60 23.40 17.25

Each

36.20

Each Each

33.10 33.10

Each Each Each

10.20 7.75 5.45

Each Each Each

12.20 10.95 8.85

Each Each Each Each

19.15 16.45 15.25 52.80

Each Each Each Each

47.05 35.25 19.45 14.80

09.071.01 09.071.02 09.071.03

Each Each Each

54.15 40.10 28.75

Page 29

DSR_2007

09.072 09.072.01 09.072.02 09.072.03 09.072.04 09.072.05 09.072.06 09.072.07 09.073 09.073.01 09.073.02 09.073.03 09.073.04 09.074 09.074.01 09.074.02 09.074.03 09.074.04 09.075 09.075.01 09.075.02 09.076

09.077

Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125 x 85 x 5.5 mm (heavy type) 125 x 70 x 4 mm (ordinary type) 100 x 85 x 5.5 mm (heavy type) 100 x 70 x 4 mm (ordinary type) 75 x 65 x 4 mm (heavy type) 75 x 40 x 2.5 mm (ordinary type) 50 x 40 x 2.5 mm (ordinary type) Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 150 x 125 x 27 x 5 mm 125 x 125 x 27 x 5 mm 100 x 125 x 27 x 5 mm 75 x 100 x 20 x 3.2 mm Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: 250 x 10 mm 200 x 10 mm 150 x 10 mm 100 x 10 mm Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300 x 16 x 5 mm 250 x 16 x 5 mm Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality) Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality) Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality)

Each Each Each Each Each Each Each

191.10 69.15 164.25 48.1 62.60 28.95 14.55

Each Each Each Each

205.55 182.30 150.40 114.10

Each One Cubic Metre Each Each

155.15 126.20 97.20 67.30

Each Each

109.20 105.70

Each

332.65

Each

307.10

09.078 Each 426.75

09.079 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers including necessary screws etc. complete (best make of approved quality): 40 mm 50 mm 65 mm 75 mm. Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) Providing and fixing bright finished brass handles with screws etc. complete : 125 mm 100 mm 75 mm Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Providing and fixing IS:3564 marked aluminium die cast body tubular type universal hydraulic door closer, with necessary accessories and screws etc. complete.

09.079.01 09.079.02 09.079.03 09.079.04 09.080

Each Each Each Each

75.95 84.10 98.05 115.45

Each

23.70

09.081 09.081.01 09.081.02 09.081.03 09.082 09.083

Each Each Each Each

103.65 91.80 68.55 56.05

Each

610.60

Page 30

DSR_2007

09.084 Providing and fixing IS: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc., complete. Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete : Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 300 mm weighing not less than 330 gms 250 mm weighing not less than 280 gms 200 mm weighing not less than 240 gms Providing and fixing bright finished brass hasp and staple (safety type ) with necessary screws etc. complete : 150 mm 115 mm 90 mm Providing and fixing chromium plated brass 100 mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). Providing and fixing chromium plated brass night latch including necessary screws etc. complete (best make of approved quality). Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (best make of approved quality ) of : Size 40 mm Size 50 mm Size 65 mm Size 75 mm Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm 100 75 mm Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 330 gms 250 mm weighing not less than 280 gms 200 mm weighing not less than 240 gms Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 x 75 x 4 mm 125 x 63 x 4 mm 100 x 75 x 4 mm 100 x 63 x 4 mm 100 x 63 x 3.2 mm 75 x 63 x 4 mm 75 x 63 x 3.2 mm 75 x 45 x 3.2 mm

Each Each

911.10 35.60

09.085 09.086 09.086.01 09.086.02 09.086.03 09.087 09.087.01 09.087.02 09.087.03 09.088

Each Each Each

82.50 69.30 58.80

Each Each Each

61.90 49.85 40.75

Each

409.30

09.089 Each 479.00

09.090

09.090.01 09.090.02 09.090.03 09.090.04 09.091 09.092 09.092.01 09.092.02 09.092.03 09.093 09.094 09.094.01 09.094.02 09.094.03 09.095

Each Each Each Each Each

78.30 95.70 108.50 121.25 31.80

Each Each Each Each

111.75 96.45 83.65 69.60

Each Each Each

90.50 83.55 70.75

09.095.01 09.095.02 09.095.03 09.095.04 09.095.05 09.095.06 09.095.07 09.095.08

Each Each Each Each Each Each Each Each

74.10 70.50 66.45 59.25 63.25 43.00 35.35 21.75

Page 31

DSR_2007

09.096

09.096.01 09.096.02 09.097

09.097.01 09.097.02 09.097.03 09.097.04 09.097.05 09.098

09.099

09.100

09.100.01 09.100.02 09.100.03 09.101

09.101.01 09.101.02 09.102

Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 300 x 16 mm 250 x 16 mm Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300 x 10 mm 250 x 10 mm 200 x 10 mm 150 x 10 mm 100 x 10 mm Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour and shade with necessary screws etc. complete. Providing and fixing 50 cm long aluminium kicking plate 100 x 3.15 mm anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete. Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm 100 mm 75 mm Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour and shade with necessary screws etc. complete : Single rubber stopper Twin rubber stopper Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.

Each Each

158.50 134.10

Each Each Each Each Each

71.45 62.20 52.00 42.75 32.15

Each

44.35

Each

115.70

Each Each Each

48.80 35.30 28.35

Each Each

19.05 53.90

Each

47.55

09.103 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) aluminium lever handles with necessary screws etc. complete (Best make of approved quality) Each Providing and fixing aluminium tee chanals ( heavy duty ) with rollers, stop end in pelmets as curtain rod. One Metre

435.90 43.05

09.104

Page 32

DSR_2007

09.105 Providing and fixing partition upto ceiling height consisting of GI frame and required board including providing and fixing of frame work made of special section power pressed / roll form GI sheet with zinc coating of grade 175 in consisting of floor and ceiling channel 50mm wide having equal flanges of 32mm and 0.5mm thick fixed to the floor and ceiling at the spacing of 610mm centre to centre with dash fastener of 12.5mm diameter 40mm length and the studs 48mm wide having one flange of 34mm and other flange 36mm and 0.50mm thick fixed verticaly within flanges of foor and ceiling channel and placed at a spacing of 610mm centre to centre by 6mm dia bolts and nuts at both ends of partition fixed flush to wall with rawl plugs at spacing of 450mm centre to centre and fixing of boards to either side of frame work by 20mm long drive wall screws on studs, floor and ceiling channels at the spacing of 300mm centre to centre, including jointing and finihing to a flush finish with recommended jointing compound, jointing tape, joint finisher and two coats of primer suitable for board as per manufacturer's specification and direction of Engineer-incharge all complete. 09.105.01 67mm overall thickness partition with 8.5mm thick double skin glass reinforced Gypsum (GRG) board conforming to IS: 2095 : part III. One Square Metre 75mm overall thickness partition with 12.5mm thick double skin plain Gypsum board conforming to IS: 2095 : part I One Square Metre 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcarius & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg/sq.cm. One Square Metre 66mm overall thickness partition using 8mm thick double skin nonasbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. Providing and fixing PTMT handles with necessary screws etc. complete (Prayag or equivalent). 125 x 34 x 24 mm weighing not less than 23 gms. 150 x 34 x 24 mm weighing not less than 26 gms. Providing and fixing PTMT butt hinges with necessary screws etc. complete . 75 x 60 x 10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms.. 100 x 75 x 10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 53 gms. Providing and fixing PTMT Tower Bolts with 12mm one piece rod inside and necessary screws etc., complete. 152 x 42 x 18 mm weighing not less than 60 gms. 202 x 42 x 18 mm weighing not less than 78 gms. Providing and fixing PTMT door clatcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. 813.80 674.45

09.105.02 09.105.03

823.10

09.105.04

One Square Metre

927.65

09.106 09.106.01 09.106.02 09.107 09.107.01 09.107.02 09.108 09.108.01 09.108.02 09.109

Each Each

33.35 36.85

Each Each

47.40 62.55

Each Each

73.00 87.80

Each

29.05

Page 33

DSR_2007

09.110

09.111

09.111.01 09.112

Providing and fixing Bamboo jaffery / fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scanting of section 50x25mm fixed with nails and GI wire on existing support complete as per directionof Engineer-incharge. Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc., with iron screws, plugs and priming coat on unexposed surfae etc., complete 2nd class teak wood. 50 x 50 mm ( base and height ) Providing and fixing 2nd class teak wood lipping / moulded beading or taj beading of size 18x5mm fixed with wooden adhessive of approved quality and screws / nails on the edges of the Pre-laminatd particle board as per direction of Engineer-in-charge. Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc., complete (Best make of approved quality) as per direction of Engineer-in-charge. Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc., complete (Best make of approved quality) Triple strip vertical type Double strip ( horizontal type ) Providing and fixing powder coated telescopic drawer channels 300mm long with necessary screws etc., complete as per directions of Engineer-in-charge. Providing and fixing sliding arrangement in racks / cup boards / cabinets shutter by P/F stainless steel rollers to run inside C or E aluminiumchannel section (The payment of C or E channel shall be made separately).

One Square Metre

207.70

One Metre

94.10

One Metre

30.10

09.113

each

203.05

09.114

09.114.01 09.114.02 09.115

each each

18.70 14.65

One set

120.75

09.116

each

7.00

09.117 Providing and fixing factory made UPVC door frame made of UPVC extruded section having an overall dimension as below (tolerance +/0.2mm, comers of the door frame to be jointed with galvanised brackets and stainless screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanised MS tube of size 19 x 19mm and 1mm +/- 0.1 mm wall thickness and 3 nos. stainless stell hinges fixed to the frame complete as per manufacturers specification and directionof Engineer-in-charge. Extruded section profile size 48 x 40 mm One Metre Extruded section profile size 42 x 50 mm One Metre Providing and frixing to existing door frames :

09.117.01 09.117.02 09.118

141.00 146.80

Page 34

DSR_2007

09.118.01 24mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59 x 24 mm and wall thickness 2mm +/- 0.2mm widh inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of MS galvanised / plastic brackets of size 75 x 220mm having wall thickness 1.0mm and stainlss steel screws. The styles of the shutter reinforced by inserting galvanised MS tube of size 20 x 20mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of 'H' section, a UPVC hollow section of size 100x24mm and 2mm +/- 0.2mm wall thickness fixed to the shutter styles by means of plastic / galvanised MS 'U' cleats. The shutter frame filled with a UPVC muti chambered single panel of sze not less than 620mm, having over al thickness of 20mm and 1mm +/0.1mm wall thickness. The panels filled vertically and the bar at two places by inserting horizontally 6mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge (For W C and bathroom door shutter). One Square Metre 09.118.02 30mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a UPVC hollow section of size 60x30mm and wall thickness 2mm +/- 0.2mm with inbuiltdecorative moulding edging on one side. The styles and rails mitred and joined at the corners by means of MS galvanised / plastic brackets of size 75x220 mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised MS tube of size 25x20mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of 'H' section, a UPVC hollow section of size 100x30mm and 2mm +/- 0.2 mm wall thickness fixed to the shutter styles by means of plastic / galvanised MS 'U' cleats. The shutter frame filled with a UPVC multichambered single panel of size not less than 620mm, having over all thickness of 20mm and 1 mm +/- 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. One Square Metre 09.118.03 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm +/- 0.3 mm. PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. An MS tube having dimensions 19mm x 19mm is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm x 11mm. Door shutter shall be reinforced with special polymeric reionforcements as per manufacturer's specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.

2190.50

2271.80

One Square Metre

2358.90

Page 35

DSR_2007

09.119

09.120 09.120.01

Providing and fixing factory made PVC door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal ot be provided through out the frame. The door frame to be fixed to the wall using MS scews of 65 / 100 mm size complete as per manufacturer's specification and direction of Engineer-in-charge. One Metre Providing and fixing to existing door frames : 30mm thick factory made panel PVC door shutter consisting of frame made out of MS tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails, MS frame shall have a coat of steel primers of approved make and manufacture. MS frame covered with 5mm thick hat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel 10mm (5mm x 2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail panellingof 5mm thick both side PVC sheet to be fitted in the MS frame welded / sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' channel using PVC solvent adhesive etc., complete as per direction of Engineer-in-charge. Manufacturer's specification & drawing (for W C and bathroom door shutter). One Square Metre

353.10

2109.95

Page 36

DSR_2007

09.120.02 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of MS tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. MS frame shall have a coat of steel primers of approved make and manufacture. MS frame covered with 5mm thick heat moulded Pre-laminatd PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on eithr side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm ()5mm x 2)thick, 20mm wide cross PVC sheet be provided as gap insert for toop rail & bottom rail, panelling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the MS frame welded / sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' channel using PVC solvent adhsive etc., complete as per direction of Engineer-in-charge, manufacturer's specification & drawing (for W C and bathroom door shutter). One Square Metre 09.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebat of 32mm x 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided ata the bottom to steady the frame. Providing and fixing to existing door frames : 30mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire resistant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithhically with 5mm thick FRP laminate for panels conforming to IS: 14856 - 2000 including fixing to frames. 30mm thick fiber glass reinforced plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of FRP laminate conforming to table -3 of IS: 14856 : 2000, complete as per direction of Engineer-incharge. Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructionsof Engineer-in-charge using 100 x 8 sheet metal CSK screws.

2580.35

One Metre

398.40

09.122 09.122.01

One Square Metre

1920.60

09.122.02

One Square Metre

2362.00

09.123

One Metre

270.65

Page 37

DSR_2007

09.124 Providing and fixing 28mm thick door shutter made of solid PVC foam profile with homogenous finecellular structure having smooth outer integral skin having 71mm width &28mm thick as styles and rails, joints are made using solvent adhesive and GI 'C' sections(39mm x 19mm x 0.6mm thick) or MS pipe (40mm x 20mm) stiffener frame insert & telescopic polymeric 'L' corners. The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturere's specifications and direction of Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look. ( for W C and bathroom door shutter ). Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W C doors) using synthetic rubber based adhesive. Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excludingportion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. Marine plywood conforming to IS: 710 Fine retardant plywood conforming to IS: 5509 Providing and fixing decorative high pressure laminated sheet of plain wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality. 1.5 mm thick 1.0 mm thhick

One Square Metre

2379.40

09.125

One Square Metre

419.35

09.126

09.126.01 09.126.02 09.127

One Square Metre One Square Metre

1186.80 1117.45

09.127.01 09.127.02 09.128

One Square Metre One Square Metre

608.15 512.30

Providing and fixing factory made Fibre glass Reinforced plastics (FRP) chajja 4mm thick of requird colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, havingsmooth gradual slpe curvature for easy drainage of water and duly reinforced by 2nos. Vertically and 1no. Horizontally 50x2mm thick MS flat with 12mm in built hole for groutingon the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings. The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight. One Square Metre 09.129 Providing and fixing cup board shutters 25mm thick, with Prelaminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade I, Type II) having one side decorative lamination and othe side balancing lamination including Iind class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-charge. One Square Metre

4452.00

1103.00

Page 38

DSR_2007

09.130 Providing and fixing cup board shutters with 25mm thick veneered particle board IS: 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in-charge. W ith decorative veneering on one side and commercial veneering on other side. One Square Metre W ith non-decorative veneering on both sides. One Square Metre Providing and fixing factory made Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade I Type II, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all-round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100 x 63 x 4mm etc., complete as per architectural drawing and direction of Engineer-in-charge (Cost of 'U' beading and hinges will be paid for separately). 25mm thick. One Square Metre Providing and fixing aluminium U beading of required size to Prelaminated / flush door shutter including fixing etc., complete as per direction of Engineer-in-charge. One Kilogram Providing and fixing in position concealed GI section for wall panelling using board of required thickness fixed on the 'W ' profile (0.55mm thick) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimetr channel is fixed on the floor and the ceiling with the nylon sleeves @ 610mm C/C with fully threaded self-tapping drive all screws. Board is fixed to the 'W ' profile with 25mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing & directions of Engineer-incharge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 09.133.01 Tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. One 09.133.01.01 10 mm thick. 09.133.02 Non-asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process ( high pressure steam cured ) as per IS: 14862 with suitable fibre cement screw. One 09.133.02.01 8 mm thick. Gypsum board conforming to IS: 2095 - 1996 : Part - I. 09.133.03 One 09.133.03.01 12.5 mm thick. Structural steel work in single section fixed with or without connecting 10.001 plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. One

09.130.01 09.130.02 09.131

963.65 852.10

09.131.01 09.132

933.50

339.75

09.133

Square Metre

657.25

Square Metre Square Metre

549.90 410.55

Kilogram

42.15

Page 39

DSR_2007

10.002 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. One Kilogram Providing and fixing in position collapsible steel shutters with vertical channels 20 x 10 x 2 mm and braced with flat iron diagonals 20 x 5 mm size with top and bottom rail of T-iron 40 x 40 x 6 mm with 40 mm dia, steel pulleys complete with bolt, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. One Square Metre Providing and fixing 1 mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40 x 40 x 6 mm angle iron, 3 mm M.S. gusset plates at the junction and corners 25 mm dia pulley, 40 x 40 x 6 mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. One Square Metre Providing and fixing 1 mm thick M.S. sheet door with frame of 40 x 40 x 6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40 x 40 x 6 mm for diagonal braces. One Square Metre Using flats 30x6 mm for diagonal braces and central cross piece. Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80 x 1.25 mm M.S. laths with 1.25 thick top cover 80 x 1.20 mm M.S. laths with 1.20 mm thick top cover 80 x 0.90 mm M.S. laths with 0.90 mm thick top cover. Providing and fixing ball bearing for rolling shutters. Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area. Exceeding 16.80 sqm in area Extra for providing grilled rollling shutters manufactured out of 8mm dia. MS bar instead of laths as per design approved by Engineer-incharge ( area of grill to be measured ) One Square Metre

46.35

10.003

2592.70

10.004

2018.70

10.005

10.005.01 10.005.02 10.006

1695.40 1600.10

10.006.01 10.006.02 10.006.03 10.007 10.008 10.008.01 10.008.02 10.009

One Square Metre One Square Metre One Square Metre Each

1208.45 965.35 911.10 356.50

One Square Metre One Square Metre

480.30 538.40

One Square Metre

214.90

10.010 Fixing standard steel glazed doors, windows and ventilators in walls with 15 x 3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows with lugs, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.) One Kilogram

23.20

Page 40

DSR_2007

10.011 Providing and fixing factory made ISI marked steel glazd doors, windows and ventilators side / top / centre hung with beading and all members such as K11 B and K12 B etc., complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted with with 15 x 3 mm lugs, 10 cm long, embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of other fittings except necessaryt hinges or pivots complete as per approved design. (sectional weight of only steel members shall be measured for payment without weight of glass & other fittings). One Kilogram Extra for providing and fixing steel beadng of approved shape and section with screw instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units. One Metre Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 z 10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. One Kilogram Providing and fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm, or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-inCharge: Profile B Profile C Profile E One Metre One Metre One Metre

178.90

10.012

21.45

10.013

51.15

10.014

10.014.01 10.014.02 10.014.03 10.015

251.90 271.65 190.80

Providing and fixing MS tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60mm thick MS sheet, jointsmitred and welded and grinded finnish with profiles of required size with 15 x 3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) of with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primers. One Kilogram 10.016 Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete:

92.25

Page 41

DSR_2007

10.016.01 10.016.02 10.016.03 10.017

10.018

10.019 10.020 10.021 10.022 10.023

10.024

10.025

10.025.01 10.025.02 10.026

10.026.01 10.026.02 10.026.03 11.001

Hot finished welded type tubes Hot finished seamless type tubes Electric resistance or induction butt welded tubes. Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs beams during laying including painting the exposed portion of loop, all as per standard design complete. Providing and fixing Circular / Hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140 mm , 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box / MS sheet box by means of 3.3 mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Providing and fixing M.S. round holding down bolts with nuts and washer plates complete. Providing and fixing bolts including nuts and washers complete. Providing and fixing MS rivets of sizes in position W elding by Electric plant including transportation of plant at site etc. complete. Providing and fixing bright finished brass casement window fasteners or peg stays to windows / ventilators with necessary welding and machine screws etc. complete. Providing and fixing 14 mm bright finished brass spring catch to steel centre hung ventilators with necessary welding and machine screws etc. complete. Steel work welded in built up sections / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. In gratings, frames, guard bar, ladders, railings, brackets, gates and similar works. Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing & staircase railing including applying a priming coat of approved steel primer. M.S. tube E.R.W . tubes G.I. pipes Brick on edge flooring with bricks of class designation 75 including cement slurry etc. complete in cement mortar with F.P.S. bricks : 1:4 ( 1 cement : 4 coarse sand ) 1:6 ( 1 cement : 6 coarse sand ) Dry brick on edge flooring in required pattern with bricks of class designation 75 on a bed of 12 mm mud mortar including filling joints with Jamuna sand ( with F.P.S bricks ) complete. Cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.

One Kilogram One Kilogram One Kilogram

61.50 66.35 79.80

Each

75.20

Each One Kilogram One Kilogram One Kilogram cm

81.20 52.05 62.75 69.90 1.45

One Kilogram.

226.05

Each

27.65

One Kilogram One Kilogram

48.95 51.20

One Kilogram One Kilogram One Kilogram

62.35 82.25 68.00

11.001.01 11.001.02 11.002

One Square Metre One Square Metre

326.00 296.20

One Square Metre

208.90

11.003

11.003.01

One Square Metre

192.95

Page 42

DSR_2007

11.004

11.005

11.006

11.006.01 11.007

11.008 11.009

52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) and top layer 12 mm thick concrete hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 stone aggregate 6 mm nominal size ) by volume, hardening compound is mixed @ 2 litre per 50 kg. of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) and top layer 12 mm thick cement hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 stone aggregate 6 mm nominal size ) by volume hardening compound is mixed @ 2 litre per 50 kg. of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Cement plaster skirting (upto 30 cm height ) with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement. 18 mm thick Cement concrete pavement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete. Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ) and top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1 mm to 4 mm nominal size laid in cement marble powder mix 3:1 ( 3 cement : 1 marble powder ) by weight in proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips ) by volume including cement slurry etc. complete : Dark shade pigment with ordinary cement. Light shade pigment with white cement Medium shade pigment with 50% white cement and 50% ordinary cement. W hite cement without any pigment. Light shade pigment with ordinary cement. Ordinary cement without any pigment.

One Square Metre

286.55

One Square Metre

318.65

One Square Metre

168.50

One Cubic Metre One Square Metre

3695.95 13.15

11.009.01 11.009.02 11.009.03 11.009.04 11.009.05 11.009.06 11.010

One Square Metre One Square Metre One One One One Square Square Square Square Metre Metre Metre Metre

305.75 337.80 319.00 317.10 313.35 291.05

11.010.01 11.010.02 11.010.03

40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 31 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ) and top layer 9 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4mm to 7 mm nominal size laid in cement marble powder mix 3:1 ( 3 cement : 1 marble powder ) by weight in proportion of 4:7 ( 4 cement marble powder : 7 marble chips ) by volume including cement slurry etc. complete. Dark shade pigment with ordinary cement. One Square Metre Light shade pigment with white cement. One Square Metre Medium shade pigment with 50% white cement and 50% ordinary cement. One Square Metre

303.60 349.25 322.45

Page 43

DSR_2007

11.010.04 11.010.05 11.010.06 11.011

W hite cement without any pigment. Light shade pigment with ordinary cement. Ordinary cement without any pigment.

One Square Metre One Square Metre One Square Metre

335.85 311.20 297.85

40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ) and top layer 12 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10 mm nominal size laid in cement marble powder mix 3:1 ( 3 cement : 1 marble powder ) by weight in proportion of 2:3 ( 2 cement marble powder mix : 3 marble chips ) by volume including cement slurry etc. complete: Dark shade pigment with ordinary cement. 11.011.01 Light shade pigment with white cement. 11.011.02 Medium shade pigment with 50% white cement and 50% ordinary 11.011.03 cement. W hite cement without any pigment. 11.011.04 Light shade pigment with ordinary cement. 11.011.05 Ordinary cement without any pigment. 11.011.06 Marble chips skirting (upto 30 cm height ) rubbed and polished to 11.012 granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 ( 3 cement : 1 marble powder ) by weight in proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips ) by volume: 18 mm thick with under layer 12 mm thick in cement plaster 1:3 ( 1 11.012.01 cement : 3 coarse sand ) 11.012.01.01 Dark shade pigment with ordinary cement.

One Square Metre One Square Metre One One One One Square Square Square Square Metre Metre Metre Metre

336.55 400.60 363.00 357.10 351.70 308.15

11.012.01.02 Light shade pigment with white cement. 11.012.01.03 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.012.01.04 W hite cement without any pigment. 11.012.01.05 Light shade pigment with ordinary cement. 11.012.01.06 Ordinary cement without any pigment. Providing and fixing glass strips in joints of terrazo/cement concrete 11.013 floors. 40 mm wide and 4 mm thick. 11.013.01 Extra for laying terrazo flooring on staircase treads not exceeding 11.014 30cm in wdth incuding cost of forming, nosing etc.. 11.015 Crazy marble stone flooring including filling the gaps with light shade pigment with white cement marble powder mixture ( 3 parts of white cement : 1 part of marble powder ) by weight in proportion of 4:7 ( 4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1 mm to 4 mm nominal size by volume ) and under layer 25 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ) rubbing, polishing and cement slurry etc. complete : 18 mm thick crazy marble stone white, black or as specified. 11.015.01

One Square Metre One Square Metre One One One One Square Square Square Square Metre Metre Metre Metre

360.90 392.95 374.15 372.25 368.50 346.20

One Metre One Square Metre

17.60 14.35

One Square Metre

482.45

Page 44

DSR_2007

11.016 Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with precast tiles on 20mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand ) : Light shade using white cement. Medium shade using 50% white cement and 50% ordinary cement. Dark shade using ordinary cement. Ordinary cement without any pigment. Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width. Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand ) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Light shade using white cement. Medium shade using 50% white cement and 50% ordinary cement. Dark shade using ordinary cement. Ordinary cement without any pigment. Chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of Cement Mortar 1:4 ( 1 cement : 4 coarse sand ): Light shade using white cement. Medium shade using 50% white cement and 50% ordinary cement. Dark shade using ordinary cement. Ordinary cement without any pigment. Chequered precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc., complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand). Light shade using white cement. Medium shade using 50% white cement 50% Grey Cement. Dark shade using ordinary cement. Ordinary cement without any pigment.

11.016.01 11.016.02 11.016.03 11.016.04 11.017 11.018

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

566.95 517.10 496.35 467.50 17.55

11.018.01 11.018.02 11.018.03 11.018.04 11.019

One Square Metre One Square Metre One Square Metre One Square Metre

665.75 605.70 577.80 548.90

11.019.01 11.019.02 11.019.03 11.019.04 11.020

One Square Metre One Square Metre One Square Metre One Square Metre

607.80 549.05 496.35 467.55

11.020.01 11.020.02 11.020.03 11.020.04 11.021

One One One One

Square Square Square Square

Metre Metre Metre Metre

775.45 613.25 454.60 425.70

Providing and fixing 10mm thick acid and / or alkali resistant tiles of approved make and colour using acid and or alkali resisting mortar bedding and joints filled with acid and or alkali resisting cement as per IS: 4457 complete as per the direction of Engineer-in-Charge. In flooring on a bed of 10mm thick mortar 1:4 ( 1 acid proof cement : 11.021.01 4 coarse sand). 11.021.01.01 Acid and alkali resistant tile. In dado / skirting on 12mm thick mortar 1:4 ( 1 acid proof cement : 4 11.021.02 coarse sand). 11.021.02.01 Acid and alkali resistant tile.

One Square Metre

One Square Metre

873.00

One Square Metre

090.15

Page 45

DSR_2007

11.022 Tile work in skirting, risers of steps and dado ( upto 2m height ) over 12mm thick bed of cement mortar 1:3 ( 1cement : 3 coarse sand ) and jointed with grey cement slurry @ 3.30 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. Marble tiles ( Polished ) Raj Nagar. 11.022.01 11.022.01.01 8 mm thick Marble stone flooring with 18 mm thick marble stone (sample of 11.023 marble shall be approved by Engineer-in- charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Markrana W hite Second Quality. 11.023.01 Rajnagar plain. 11.023.02 Agaria W hite 11.023.03 Black Zebra 11.023.04 Udaipur green marble 11.023.05 Pink plain marble 11.023.06 Extra for pre finished nosing to treads of steps of marble stone. 11.024 Extra for marble stone flooring in treads of steps and risers using 11.025 single length upto 2.00 metre., 11.026 Kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 ( 1 cement : 4 coarse sand): 25 mm thick. 11.026.01 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and 11.027 pillars laid on 12 mm (average) thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 40 mm thick fine dressed stone flooring over 20 mm (average) thick 11.028 base of cement mortar 1:5 ( 1 cement : 5 coarse sand ) with joints finished flush. Red sand stone. 11.028.01 W hite sand stone. 11.028.02 40 mm thick fine dressed stone flooring over 20 mm (average) thick 11.029 base of cement mortar 1:5 ( 1 cement : 5 coarse sand ) including pointing with cement mortar 1:2 ( 1 cement : 2 stone dust ) with an admixture of pigment to match the shade of stone. Red sand stone. 11.029.01 W hite sand stone. 11.029.02 40 mm thick rubbed stone flooring over 20 mm (average) thick base 11.030 of cement mortar 1:5 ( 1 cement : 5 coarse sand ) with joints 3mm thick, side buttered with cement mortar 1:2 ( 1 cement : 2 stone dust ) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone. 11.030.01 W hite sand stone. 11.030.02 Extra for pre finished nosing in treads of steps of Kota stone / Sand 11.031 stone slab. Extra for Kota stone / Sand stone in treads of steps and risers using 11.032 single length upto 1.05 metre. 25 mm wooden planking, tongued and grooved in flooring including 11.033 fixing with iron screws complete with

One Square Metre

570.40

One Square Metre One Square Metre One Square Metre

One Metre One Square Metre

2637.95 892.15 1673.55 892.15 1112.55 1067.15 105.20 122.35

One Square Metre

694.40

One Square Metre

676.75

One Square Metre One Square Metre

309.40 334.95

One Square Metre One Square Metre

353.75 379.30

One Square Metre One Square Metre One Metre One Square Metre

386.65 412.20 26.40 6.45

Page 46

DSR_2007

11.033.01 11.033.02 11.034

11.035

Second class teak wood Second class deodar wood 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick levelling layer of cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm nominal size )to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen ( blown type) upto half depth, planed, levelled smooth and finished complete. Providing and fixing M.S. angle 50 x 50 x 5 mm to act as nosing with lugs of M.S. flat 10 x 5 mm 10 cm long forked at end 60 cm apart (minimum three lugs to be provided ) including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete.

One Square Metre One Square Metre

1752.50 1433.70

One Square Metre

3528.10

One Kilogram

48.05

11.036 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 Kg. per sqm. including pointing in white cement mixed with pigment of matching shade complete. One Square Metre Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer ) of 1st quality conforming to IS: 15622 ofapproved make in colours such as W hite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc. complete. One Square Metre Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in all colours, shades, except W hite, Ivory, Grey, Fume Red Brown laid on 20 mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc. complete. One Square Metre 11.039 Providing and laying rectified Glazed Ceramic floor riles 300 x300mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622, of approved mak in colours W hite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc. complete. One Square Metre Providing and laying rectified Glazed Ceramic floor tiles 300 x 300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 156225, of approved make in all colours, shades except W hite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement: 4 Coarse snad) including pointing the joints with white cement and matching pigments etc. complete. One Square Metre

556.60

11.037

598.65

11.038

630.80

759.90

11.040

800.40

Page 47

DSR_2007

11.041 Providing and laying Vitrified floor tiles in different sizes (thhickness to be specified by the manufacturer) with water aborption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laidon 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of Tile 50x50 cm. Size of Tile 60 x 60 cm. Size of Tile 80 x 80 cm. Size of Tile 100 x 100 cm. Deduct for not using 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) bedding in laying of floor tiles. Fixing Glazed / Ceramic / Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (W ater based) conforming to IS: 15477, using 5 kg. adhesive per sqm of tile area, in average 3mm thickness. Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved faces ) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/sqm. 0.80 mm thick with zinc coating not less than 275 gm/sqm. 0.63 mm thick with zinc coating not less than 275 gm/sqm. Extra for providing and fixing corrugated G.S. sheet vertically or to a pitch exceeding 60 degrees. Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre for chimney stacks, sky light etc. 1.00 mm thick 0.80 mm thick 0.63 mm thick Extra for providing and fixing curved C.G.S. sheets in roofing : Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre : 1.00 mm thick 0.80 mm thick 0.63 mm thick 0.80 mm thick 0.63 mm thick Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/sqm. 0.63 mm thick with zinc coating not less than 275 gm/sqm. Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350 gm/sqm.

11.041.01 11.041.02 11.041.03 11.041.04 11.042 11.043

One One One One

Square Square Square Square

Metre Metre Metre Metre

966.35 1031.85 1478.30 1733.05 233.95

One Square Metre.

One Square Metre

224.70

12.001

12.001.01 12.001.02 12.001.03 12.002 12.002

One Square Metre One Square Metre One Square Metre One Square Metre

612.85 515.30 432.25 2.80

12.002.01 12.002.02 12.002.03 12.003 12.003 12.003.01 12.003.02 12.003.03 12.003.04 12.003.05 12.004

One Metre One Metre One Metre

16.65 13.30 13.30

One One One One One

Metre Metre Metre Square Metre Square Metre

97.65 78.00 78.00 3.15 2.55

12.004.01 12.004.02 12.005

One Metre One Metre

313.60 270.95

12.005.01

One Metre

617.45

Page 48

DSR_2007

12.006

12.006.01 12.007

12.007.01 12.007.02 12.008

12.009

Providing flashing of 40 cm over all width in plain, G.S. sheet fixed with polymer coated J.or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 ( 1 cement : 3 coarse sand ). 1.00 mm thick zinc coating not less than 275 gm/sqm. Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/sqm. 0.63 mm thick with zinc coating not less than 275 gm/sqm. Providing non-asbestos high impact Polypropylene reinforced cement 6mm thick corrugated sheets (as per IS: 14871) roofing upto any pitch and fixing with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers of with self drilling fastener and EPDM washers etc., complete excluding the cost of purlins, rafters and trusses corrugated sheets and including cutting to size and shape wherever required. Extra for straight cutting in non-asbestos polypropylene reinforced cement corrugated, semi-corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimetre for chimney stacks,skylights etc. Extra for circular cutting in non-asbestos Polypropylene reinforced cement corrugated / semi-corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimetre.

One Metre

223.55

One Metre One Metre

283.70 248.20

One Square Metre.

294.95

One Metre

13.30

12.010

One Metre One Metre

36.80 73.65

12.011 12.012 Extra for providing and fixing wind ties of 40 x 6 mm flat iron section. Providing and fixing ridges and hips in non-asbestos fibre cement high impact Polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc,., complete. Corrugated serrated ajustable ridges Plain wing adjustable ridges Close fitting adjustable ridges Unserrated adjustable hips. Providing and fixing non-asbestos fibre cement high impact Polypropylene reinforced roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts, G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc., complete: Corrugated apron pices. Eave's filler pieces North light curves Ventilator curves Barge boards Ridge finials. Special noth light curves. Stype louvers. Providing flat iron brackets 50 x 3 mm size with necessary bolts, nuts and washers etc. for fixing asbestos cement / G.S.sheets gutters with purlins.

12.012.01 12.012.02 12.012.03 12.012.04 12.013

One One One One

Metre Metre Metre Metre

263.15 282.70 348.75 292.10

12.013.01 12.013.02 12.013.03 12.013.04 12.013.05 12.013.06 12.013.07 12.013.08 12.014

One Metre One Metre One Metre One Metre One Metre Pair Each One Metre.

180.05 121.95 268.10 353.95 304.00 115.00 362.05 175.35

One Metre

22.45

Page 49

DSR_2007

12.015 Painting top of roofs with bitumen of approved quality at 17 kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm. including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete. W ith residual type petroleum bitumen of penetration 80 / 100 One Square Metre 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa at 35 kg per cum of earth and gobri leaping with mix 1:1 ( 1 clay : 1 cow dung) and covered with flat tile bricks of class designation 100 grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement and finished neat : W ith F.P.S. brick tiles One Square Metre

12.015.01 12.016

63.00

12.016.01 12.017

220.85

10cm thick (average ) mud phaka of damped brick earth on roofs laid to slope consolidated and plastered with 25mm thick mud mortar with bhusha at 35kg per cum of earth and gobri leaping with mix 1:1 ( 1 clay : 1 cow dung ) and covered with machine moulded tile bricks of class designation 125 conforming to IS: 2690 ( Part I ) 1992 grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement and finished neat. W ith machine moulded FPS brick tiles. 12.017.01 Extra for every additional 1 cm thickness of mud phaska. 12.018 Providing and laying brick tiles of class designation 100 over mumty 12.019 roofs grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral wather proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat : W ith F.P.S. brick tiles 12.019.01 Providing and laying pressed clay tiles ( as per approved pattern 12.020 20mm nominal thickness and of approved size ) on roofs jointed with cement mortar 1:4 ( 1 cement : 4 coarse sand ) mixed with 2% integral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) and finished neat complete. Providing gola 75 x 75 mm in cement concrete 1:2:4 ( 1 cement : 2 12.021 coarse sand : 4 stone aggregate 10mm and down gauge ) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design : In 75 x 75 mm deep chase. 12.021.01 Making khurras 45 x 45 cm with average minimum thickness of 5 cm 12.022 cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over P.V.C. sheet 1 m x1m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement rounding the edge and making and finishing the outlet complete. Providing sand stone slab for roofing and laying them in cement 12.023 mortar 1:4 ( 1 cement : 4 coarse sand ) over wooden karries or R.C.C. battens (Karries and battens to be paid seperately) including pointing the ceiling joints with cement mortar 1:3 ( 1 cement : 3 fine sand ) complete. Red sand stone slab. 12.023.01 12.023.01.01 40 to 50 mm thhick. W hite sand stone slab : 12.023.02

One Square Metre. One Square Metre

254.70 5.15

One Square Metre

184.35

One Square Metre

390.60

One Metre

67.35

Each

108.00

One Square Metre

283.30

Page 50

DSR_2007

12.023.02.01 12.024

40 to 50 mm thick

One Square Metre

302.45

Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately): Natural colour insulating board 12.024.01 12.024.01.01 12 mm thick W hite face insulating board 12.024.02 12.024.02.01 12 mm thick Flame retardent face insulating board 12.024.03 12.024.03.01 12 mm thick Providing and fixing flat pressed 3 layer medium density particle 12.025 board or graded particle baord (Grade I) IS:3087 marked in ceiling with necessary nails etc. complete ( frame work to be paid separately): 12 mm thick 12.025.01 12.026 Providing and fixing plain Multipurpose Cement Board ( High Pressure steam cured ) as per IS: 14862 : 2000 ) with suitable fibre cement screw in ceiling etc., (frame work to be paid separately) : 6 mm thick cement board. 12.026.01 Extra for Circular cutting and waste in ceiling with : 12.027 2nd class teak wood planks 20 mm thick 12.027.01 Natural colour insulating board 12.027.02 12.027.02.01 12 mm thick W hite face insulating board : 12.027.03 12.027.03.01 12 mm thick Flame retardant face insulating board 12.027.04 12.027.04.01 12 mm thick Standard quality hard board sheet : 12.027.05 12.027.05.01 3 mm thick 12.027.05.02 4.5 mm thick. Extra for providing and fixing ceiling to curved surfaces in narrow 12.028 widths Providing and fixing false ceiling with 12 mm thick plain / semi 12.029 perforated or with design ceiling tiles of BW P type phenol formaldehyde synthetic resin bonded presed particle board conforming to IS: 3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-ssections 35x15x1.5 mm size main runners and cross runners 23.5x19x1.5mm fixed to main runners placed 600mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6mm dia MS rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with CP brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately ). Extra for providing 3mm thick translucent white acrylic plastic sheets 12.030 of approved quality in false ceiling instead of 12mm thick plain / or with design particle board ceiling tiles in item above. 12.031 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5 m above floor level over first class kail wood strips 25 x 6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately)

One Square Metre One Square Metre One Square Metre

311.40 393.15 353.55

One Square Metre

417.10

One Square Metre One Metre One Metre One Metre One Metre One Metre

317.45 186.40 92.55 102.75 97.80 81.05 83.75 65.45

One Square Metre

One Square Metre

202.45

One Square Metre

336.85

Page 51

DSR_2007

12.031.01 12.031.02 12.032 12.033 12.034

Flat surfaces Curved surfaces Extra for any sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling. Extra for providing plaster of Paris (Gypsum anhydrous)ceiling above 5 metres height from floor level. Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183 density 24 kg/Cum. 50 mm thick, wrapped in 200 G Virgin polythene bags fixed to Ceiling with metallic cleats (50x50x3 mm) @ 60 cm. and wire mesh of 12.5 mm x 24g wire and mesh, for top most ceiling of building.

One Square Metre One Square Metre One Square Metre

402.40 452.35 104.70

per Square Metre per metre height 38.90

One Square Metre

310.10

12.035 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183 density 16kg/cum , 50mm thhick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. Thermal insulation of roofing with Expanded polystyrene fixed with 12.036 suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge : W ith Type N - Normal 50 mm thick. 12.036.01 W ith Type SE - Self Extinguishing type 50 mm thick. 12.036.02 Providing and fixing 100 mm diameter and 60 cm long rain water 12.037 spout in cement mortar 1:4 ( 1cement : 4 fine sand ). Stone ware spout. 12.037.01 Providing and fixing M.S. holder bat clamps of approved design to 12.038 C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) and cost of cutting holes and making good the walls etc. 100 mm diameter 12.038.01 150 mm diameter 12.038.02 Providing lead caulked joints to sand cast iron rain water pipes and 12.039 fittings : 100 mm dia pipe 12.039.01 150 mm dia pipe 12.039.02 Providing, fixing and embedding sand cast iron accessories for rain 12.040 water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) Sand cast iron plain shoes 12.040.01 12.040.01.01 150 mm diameter 12.041 Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diameter 110 mm diameter Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised - PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler

One Square Metre.

168.35

One Square Metre One Square Metre

156.75 186.10

each

36.15

Each Each

65.35 73.45

Each Each

126.50 175.30

Each

278.25

12.041.01 12.041.02 12.042

One Metre One Metre

95.00 163.40

12.042.01

Page 52

DSR_2007

12.042.01.01 12.042.01.02 12.042.02 12.042.02.01 12.042.02.02 12.042.03 12.042.03.01 12.042.03.02 12.042.04 12.042.04.01 12.042.04.02 12.042.05 12.042.05.01 12.042.05.02 12.042.06 12.042.06.01 12.042.06.02 12.043

75 mm 110 mm Single Pushfit Coupler 75 mm 110 mm Single tee with door 75 x 75 x 75 mm 110 x 110 x 110 mm Single tee without door 75 x 75 x 75 mm 110 x 110 x 110 mm Bend 87.5 degree 75 mm bend 110 mm bend Shoe (Plain) 75 mm Shoe 110 mm Shoe Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 75 mm 110 mm Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.

Each Each Each Each Each Each Each Each Each Each Each Each

81.40 101.65 101.15 138.85 177.45 260.70 157.70 208.45 88.40 134.20 152.25 263.10

12.043.01 12.043.02 12.044 12.045

Each Each Each

79.50 96.90 23.40

Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 22 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x0.55 mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45 mm x 15 mm x 0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick botton wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive-all screws @ 230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the coat of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with .

Page 53

DSR_2007

12.045.01 12.046

12.5 mm thick tapered edge gypsum board conforming to IS: 2095 Part I. One Square Metre Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8mm and weighing not less than 100 gms. Each Providing and fixing UV stabilised fibre glass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. GI plain / bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX pane rovigs incorporating minimum 0.3% Ultra-Violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2mm thick corrugated ( 2.5" or 4.2" or 6" ) or step-down ( 2" or 3" or 6" ) as specified. 2 mm thick flat. Providing and fixing on roof pressed clay tiles ( Mangalore tile ) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete ( steel frame work to be paid separately ) Providing and laying on roof pressed clay tile ridge ( Mangalore tile ) of 20mm thickness and of approved pattern on steel frame work complete ( steel frame work to be paid separately ).

502.10

86.15

12.047

12.047.01 12.047.02 12.048

One Square Metre One Square Metre

785.35 673.35

One Square Metre

209.40

12.049

One Square Metre

105.00

12.050 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm +/- 5% total coated thickness (TCT) Zinc coating 120gms as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester rop coat 15-18 microns, sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12metre or as directed by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws of size ( 5.5 x 55mm ) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and GI limpet washers or with GI limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / - 5% total coated thickness (TCT) Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling / self tapping screws or with polymer coated / J or L hooks, bolts and nuts and or GI seam bolts and nuts, GI plain and bitumen washers complete.: Ridges plain ( 500 - 600 mm ) Flashings / Aprons ( Upto 600 mm ) North light curves. Barge Board ( Upto 300 mm ) Crimp curve. Gutter ( 600mm over all girth ).

One Square Metre

440.65

12.051

12.051.01 12.051.02 12.051.03 12.051.04 12.051.05 12.051.06

One One One One One One

Metre Metre Metre Metre Metre Metre

458.15 448.15 504.75 416.90 537.15 547.80

Page 54

DSR_2007

12.052 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanised @ 170 gsm/sqm ) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.3mm and laying false ceiling tiles of approved texture in the grid including wherever required, cutting / making opening for services like diffusers, grills, light fittings, smoke detectors etc., Main "T" runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to cnter along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. ( The rate is excluding the cost of tiles which will be paid for separately ). 12 mm cement plaster of mix : 1:4 ( 1 cement : 4 fine sand ) 1:6 (1 cement : 6 fine sand ) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 ( 1 cement : 4 fine sand ) 1:6 ( 1 cement : 6 fine sand ) 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand) 1:6 ( 1 cement : 6 fine sand ) 12 mm cement plaster of mix : 1:4 ( 1 cement : 4 coarse sand ) 1:6 ( 1 cement : 6 coarse sand ) 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 ( 1 cement : 4 coarse sand ) 1:6 ( 1 cement : 6 coarse sand ) 20 mm cement plaster of mix : 1:4 ( 1 cement : 4 coarse sand ) 1:6 ( 1 cement : 6 coarse sand ) 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand ) 1:4 ( 1 cement : 4 fine sand ) 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand ) 1:4 ( 1 cement : 4 fine sand ) Cement plaster 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement : 12mm cement plaster. 20 mm cement plaster.

One Square Metre One Square Metre One Square Metre

358.25 77.55 67.65

13.001 13.001.01 13.001.02 13.002 13.002.01 13.002.02 13.003 13.003.01 13.003.02 13.004 13.004.01 13.004.02 13.005 13.005.01 13.005.02 13.006 13.006.01 13.006.02 13.007 13.007.01 13.007.02 13.008 13.008.01 13.008.02 13.009 13.009.01 13.009.02

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

90.35 78.55 110.45 95.10 82.55 72.70

One Square Metre One Square Metre One Square Metre One Square Metre

96.35 84.55 118.25 102.90

One Square Metre One Square Metre

107.80 97.90

One Square Metre One Square Metre

122.50 110.70

One Square Metre One Square Metre

112.80 154.00

Page 55

DSR_2007

13.010

13.011

13.012

13.013 13.014 13.015 13.016 13.016.01 13.017

13.018 13.019

13.019.01 13.020

13.021 13.022 13.023 13.023.01 13.023.02 13.024 13.024.01 13.024.02 13.025 13.025.01 13.025.02 13.025.03 13.026

15 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall. 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand )finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand ) 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand ) and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand ) finished rough with sponge. 12 mm cement plaster 1:2 ( 1 cement : 2 stone dust ). 15 mm cement plaster 1:2 ( 1 cement : 2 stone dust ) on the rough side of single or half brick wall. 20 mm cement plaster 1:2 ( 1 cement : 2 stone dust ) 6 mm cement plaster of mix : 1:3 ( 1 cement : 3 fine sand ) 6 mm cement plaster 1:3 ( 1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. Neat cement punning. Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 ( 1 cement : 4 coarse sand ) and top layer 10 mm cement plaster 1:3 ( 1 cement : 3 fine sand ) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement. Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ) and top layer 10 mm cement plaster with cement mortar 1:3 ( 1 cement :3 fine sand ) mixed with 10% finely grounded hydrated lime by volume of cement. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. Extra for plastering on circular work not exceeding 6 m in radius : In one coat In two coats Extra for plastering done on moulding cornices or architraves including neat finish to line and level : In one coat In two coats. Extra for plastering : Spherical ceiling Groined ceiling Flewing soffits Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.

One Square Metre

128.50

One Square Metre

111.15

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

123.50 105.65 123.90 154.20 62.15

One Square Metre One Square Metre

85.55 21.40

One Square Metre

196.00

One Square Metre

188.20

Per bag of 50kg cement used in mix. 28.85 One Square Metre One Square Metre One Square Metre 16.80 7.40 11.35

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

103.75 170.50 27.50 30.15 17.90

One Square Metre One Square Metre

47.20 16.60

13.027 Extra for lining out plaster to imitate stone or concrete blocks walling

Page 56

DSR_2007

13.028 13.028.01 13.028.02 13.028.03 13.028.04 13.029 13.029.01 13.029.02 13.029.03 13.029.04 13.030

12 mm thick plain cement mortar bands in cement mortar 1:4 ( 1 cement : 4 fine sand ): Flush Band Sunk Band Raised Band Moulded Band 18 mm thick plain cement mortar band in cement mortar 1:4 ( 1 cement : 4 fine sand ): Flush Band Sunk Band Raised Band Moulded Band 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 ( 1 cement : 5 coarse sand ) top layer 6 mm thick with cement mortar 1:4 ( 1 cement : 4 fine sand ) Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand ) : Flush / Ruled / Struck or W eathered pointing Raised and cut pointing Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand ) : Flush / Ruled / Struck or W eathered pointing. Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand ) : Flush / Ruled pointing Ruled and cut pointing Raised and cut pointing on stone work in white cement mortar 1:3 ( 1 white cement : 3 marble dust ) Pointing on stone slab ceiling with cement mortar 1:2 ( 1 cement : 2 fine sand ) : Flush / Ruled pointing. Extra for pointing on walls on the outside at height more than 10 m from ground level for every additional height of 3 m or part thereof W hite washing with lime to give an even shade : New work (three or more coats) Satna lime wash on walls one coat.

cm cm cm cm

per per per per

metre. metre. metre. metre.

1.35 1.45 1.65 2.60

cm cm cm cm

per per per per

metre. metre. metre. metre.

1.70 1.85 2.05 3.55

cm per metre.

3.55

13.031 13.031.01 13.031.02 13.032 13.032.01 13.033 13.033.01 13.033.02 13.034 13.035 13.035.01 13.036

One Square Metre One Square Metre

45.40 72.90

One Square Metre.

62.60

One Square Metre One Square Metre One Square Metre

62.50 112.00 125.95

One Square Metre

36.45

One Square Metre One Square Metre One Square Metre

3.10 6.75 2.75

13.037 13.037.01 13.038 13.039 13.039.01 13.039.02 13.040

Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. One Square Metre New work (two or more coats) with a base coat of whiting. One Square Metre Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including priming coat with cement primer. Distempering with 1st quality acrylic washable distemper (ready mixed ) of approved manufacturer and of required shade and colour complete, as per manufacturers specification. Two or more coats on new work.

9.30 9.10

One Square Metre

26.30

13.041 13.041.01 13.042.

One Square Metre

41.55

13.042.01

One Square Metre One Square Metre

23.55

Page 57

DSR_2007

13.043 13.043.01 13.044 13.044.01 13.045 13.045 13.045.01

Applying one coat of cement primer of approved brand and manufacture on wall surface : Cement primer Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 Kg/10 Sqm.) Finishing walls with textured exterior paint of required shade : Finishing walls with textured exterior paint of required shade. New work (Two or more coats applied @ 3.28 ltr./10sqm ) over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.) New work (Two or more coats applied @ 3.28 ltr/10 sqm.) over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm. Finishing walls with Acrylic Smooth exterior paint of required shade : New work ( Two or more coat applied @ 1.67 ltr/10sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm.) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work ( Two or more coats applied @ 1.43 ltr./10 sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm. ) Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied @ 1.25 ltr./10sqm over and including one coat of special primer applied @ 0.75 ltr./10sqm. Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coats applied @ 0.90 ltr./10sqm over an under coat of primer applied @ 0.75 ltr./10 sqm of approved brand or manufacture. Painting steel work with Deluxe Multi Surface Paint of required shade. Two or more coats applied @ 0.90 ltr. / 10 sqm over an under coat of primer applied @ 0.80 ltr. / 10sqm of approved brand or manufacture. Extra for applying water proofing cement paint as primer applied @ 2.2 kg/10 sqn instead of primer for exterior finishing in item No. 13.48.1. Applying priming coat : W ith ready mixed pink or Grey primer of approved brand and manufacture on wood work ( hard and soft wood ) W ith ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. W ith ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanied iron / steel works. W ith ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work ( second coat ). Painting one thin coat with white lead of approved brand and manufacture on wet or patchy portion of plastered surfaces. Finising with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.

One Square Metre

17.20

One Square Metre

30.80

One Square Metre.

96.25

13.045.01

One Square Metre One Square Metre

96.25

13.046 13.046.01

One Square Metre

50.40

13.047 13.047.01

One Square Metre

60.10

13.048 13.048.01 13.048.02

One Qquare Mdtre

62.25

One Square Metre

51.55

13.048.03

One Square Metre

53.55

13.049

One Metre

2.60

13.050 13.050.01 13.050.02 13.050.03 13.050.04 13.051 13.052

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre

16.55 15.75 12.65 7.15 22.60

13.052.01

On Steel work.

One Square Metre

75.25

Page 58

DSR_2007

13.052.02 13.053

On concrete work. Painting on GS sheet with synthetic enamel paintof approved brand and manufacture of required colour to give an even shade : New work ( two or more coats ) including a coat of approved steel primer but excluding a coat of mordant solution. Applying a coat of mordant solution on G.S. sheet: W ith a solution of 38 gms of copper acetate in a litre of soft water. W ith a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water. Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work: 100 mm diameter pipes 150 mm diameter pipes Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture and required colour over a priming coat of approved steel prmer on new work : 100 mm diameter pipes 150 mm diameter pipes Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) Providing and applying two coats of fire retardant paint unthinned on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively. W all painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work. Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. Varnishing with varnish of approved brand and manufacture:

One Square Metre

77.75

13.053.01 13.054 13.054.01 13.054.02

One Square Metre One Square Metre

37.55 11.60

One Square Metre

11.45

13.055

13.055.01 13.055.02 13.056

One Metre One Metre

15.05 22.50

13.056.01 13.056.02 13.057 13.057.01 13.058

One Metre One Metre

16.35 24.35

One Square Metre

12.80

One Square Metre One Qquare Metre

229.80 14.65

13.059 13.060 13.060.01 13.061 13.061.01 13.062 13.062.01 13.063 13.063.01 13.064 13.064.01 13.065 13.065.01 13.066 13.066.01 13.067

One Square Metre

40.05

One Square Metre

35.35

One Square Metre

51.30

One Square Metre

28.60

One Square Metre

32.40

One Square Metre

24.80

One Square Metre

37.05

Page 59

DSR_2007

13.067.01 13.067.02 13.068 13.068.01 13.069 13.069.01 13.070 13.071 13.072

Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. Two or more coats glue sizing with spar varnish or an under coat of flatting varnish. French spirit polishing: Two or more coats on new works including a coat of wood filler. Polishing on wood work with ready made wax polish of approved brand and manufacture: New work Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. Lettering with black Japan paint of approved brand and manufacture. W ashed stone grit plaster on exterior walls of height upto 10 M. above level in two layers under layer 12 mm cement plaster 1:4 ( 1 cement : 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/2:2 ( 1 cement : 1/2 coarse sand : 2 stone chipping 10 mm nominal size ) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in-Charge (Payment for providing grooves shall be made separately) Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 15 mm wide and 15 mm deep groove 20 mm wide and 15 mm deep groove. Extra for washed grit plaster on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. Extra for washed stone grit plaster on circular work not exceeding 6 m in radius (in two coats). Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-inCharge. Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster.

One Square Metre One Square Metre One Square Metre

49.20 50.80 75.60

One Square Metre One Sqtare Metre

35.80 16.15

per letter per cm height. .90 0

One Square Metre

262.20

13.073

13.073.01 13.073.02 13.074

One Metre One Metre

13.30 13.65

One Square Metre One Square Metre

40.75 22.90

13.075 13.076

One Metre One Square Metre

13.30 60.40

13.077 13.078

14.001

Providing and applying 12mm thick ( average ) premixed formulated one coat gypsum light weight plaster having additives and light weight aggregate as vermiculite / perlite respectively conforming to IS: 2547 ( Part - I & II) 1976, applied on hacked / uneven background such as bare brick / block / RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc., complete. One Square Metre Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead :

143.10

Page 60

DSR_2007

14.001.01 14.001.02 14.002

W ith cement mortar 1:4 ( 1 cement : 4 fine sand ) W ith cement mortar 1:4 ( 1 cement : 4 coarse sand) Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 metres lead : Door chowkhats W indow chowkhats Clerestory window chowkhats. Fixing chowkat in existing opening in Brick / RCC wall with dash fasteners / chemical fasteners of appropriate size / chemical fastener ( 3 nos. on each vertical member of door chowkat and 2 nos. on each vertical member of window chowkats including cost of dash fasteners / chemical fastener.

One Square Metre One Square Metre

114.35 120.70

14.002.01 14.002.02 14.002.03 14.003

Each Each Each

354.45 214.20 154.60

Each

81.05

14.004 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of muba / rubbish to the nearest municipal dumping ground. For door / window / clerestory window. One Square Metre Renewing glass panes, with putty and nails wherever necessary : Float glass panes of thickness 4 mm. Float glass panes of thickness 5.5 mm. Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4 mm. Float glass panes of thickness 5.5 mm. Renewing glass panes and refixing existing wooden fillets: Float glass panes of thickness 4 mm Float glass panes of thickness 5.5 mm. Supplying and fixing new wooden fillets wherever necessary : 2nd class teak wood fillets. Hollock wood fillets Renewal of old putty of glass panes (length) Refixing old glass panes with putty and nails Fixing old glass panes with wooden fillets (excluding cost of fillets) 14.012 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete. 14.013 Regarding terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster preparing the surface of mud phaska to proper slope relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 ( 1 cement : 3 fine sand ) including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground ( the cost of the new tiles or brick excluded ) within 50 metres lead. One Square Metre

14.004.01 14.005 14.005.01 14.005.02 14.006 14.006.01 14.006.02 14.007 14.007.01 14.007.02 14.008 14.008.01 14.008.02 14.009 14.010 14.011

204.10

One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre One Square Metre One One One One Metre Metre Metre Square Metre

427.60 545.15 498.55 616.10 435.80 553.35 16.95 14.40 9.90 128.55 102.65

One Square Metre

Each

113.85

116.05

Page 61

DSR_2007

14.014

14.014.01 14.015

14.015.01 14.016

14.016.01 14.016.01.01 14.016.01.02 14.016.02 14.016.02.01 14.016.02.02 14.017

14.018

14.018.01 14.018.02 14.019

14.020

Replacing sand stone slabs in roofing laid in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead: Red / white sand stone slabs 30 to 50 mm thick Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : Sal wood battens Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead: Not exceeding 4.00 metres in length Sal wood beams Hollock wood beams Above 4.00 metres and upto 5.00 metres length. Sal wood beams Hollock wood beams Raking out joints in lime or cement mortar and preparing the surface for repainting or replastering including disposal of rubbish to the dumping ground within 50 metres lead. Flush pointing with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska : W ith F.P.S. brick tiles. W ith modular brick tiles Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand.

One Square Metre

322.00

One Cubic Metre

28074.55

One Cubic Metre One Cubic Metre One Cubic Metre One Cubic Metre

28950.90 28831.20 29400.30 29278.20

One Square Metre

10.85

One Square Metre One Square Metre

24.90 25.60

One Kg

0.80

One Metre

34.35

14.021 Renewing bottom rail and / or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. Renewing W rought Iron or M.S. W heel or roller of steel door or gate 14.022 and fitting and fixing the same with necessary clamps, nuts and bolts / welding and erection etc. complete. W heel 50 mm dia. and below 14.022.01 W heel above 50 mm dia. 14.022.02 Pumping out water caused by springs, tidal or river seepage, broke 14.023 water mains or drains and the like. Mud mortar 14.024 Brick work with bricks of class designation 75 in mud mortar. 14.025 Providing and fixing 25 mm thick shutters for cup board etc. 14.026 Panelled or panelled & glazed shutters : 14.026.01 14.026.01.01 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.026.01.02 1st class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. Glazed shutters : 14.026.02

One Kg

77.90

per wheel per wheel One kilolitre One Cubic Metre One Cubic Metre

88.15 127.50 40.75 156.85 1590.25

One Square Metre One Square Metre

2400.25 1563.50

Page 62

DSR_2007

14.026.02.01 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.026.02.02 1st class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.027 Providing and fixing plain jaffri door and window shutters including bright or / and black enamelled M.S. butt hinges with necessary screws 35 x 10 mm laths placed 35 mm apart ( frames to be paid separtely ) including fixing 50 x 12 mm beading complete with Second class teak wood. 14.027.01 Providing and fixing curtain rods of 1.25 mm thick brass plates with 14.028 two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 20 mm diameter 14.028.01 25 mm diametre 14.028.02 Providing and fixing M.S. round or square bars with MS flats at 14.029 required spacing in wooden frames of windows and clerestory windows. Providing joists (karries) including hoisting fixing in position and 14.030 applying wood preservative on unexposed surface etc. complete with : Sal wood 14.030.01 Hollock wood 14.030.02 Providing and fixing bright finished brass single acting spring hinges 14.031 with necessary screws etc. complete : 150 mm 14.031.01 125 mm 14.031.02 100 mm 14.031.03 Providing and fixing bright finished brass double acting spring hinges 14.032 with necessary screws etc. complete : 150 mm 14.032.01 125 mm 14.032.02 100 mm 14.032.03 Providing and fixing bright finished brass flush bolts with necessary 14.033 screws etc. complete : 250 mm 14.033.01 150 mm 14.033.02 100 mm 14.033.03 14.034 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion screws etc., to suit shutter thickness complete. 14.035 Providing and fixing bright finished brass hard drawn hooks and eyes 300 mm 14.035.01 250 mm 14.035.02 200 mm 14.035.03 150 mm 14.035.04 100 mm 14.035.05 Providing and fixing bright finished brass fan light pivot with 14.036 necessary screws etc. complete. Providing and fixing 300 mm long bright finished brass chain with 14.037 hook for fan light including necessary screws etc. complete. Providing and fixing bright finished brass quadrant stay 300 mm long 14.038 with necessary screws etc. complete. Providing and fixing bright finished brass helical door spring (superior 14.039 quality).

One Square Metre One Square Metre

2538.20 1638.75

One Square Metre

1532.40

One Metre One Metre

116.20 134.75

One Kg

44.40

One Cubic Metre One Cubic Metre

27555.70 27437.30

Each Each Each

252.85 204.05 142.65

Each Each Each

388.75 271.45 220.45

Each Each Each

106.80 84.10 59.70

Each

127.55

Each Each Each Each Each Each Each Each Each

54.25 50.30 46.45 43.45 36.00 20.85 20.50 90.20 231.80

Page 63

DSR_2007

14.040 14.040.01 14.040.02 14.040.03 14.040.04 14.040.05 14.041

Providing and fixing chromium plated brass butt hinges with necessary screws etc. complete. 125 x 70 x 4 mm (Ordinary type) 100 x 70 x 4 mm (ordinary type) 75 x 65 x 4 mm (heavy type) 75 x 40 x 2.5 mm (ordinary type) 50 x 40 x 2.5 mm (ordinary type) Providing and fixing 85 x 42 mm chromium plated brass pull bolt lock with necessary screws, nuts, bolts and washers etc. complete. W hite washing with lime to give an even shade: Old work ( two or more coats ) Old work ( one or more coats ) Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to given an even shade. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. Old work (one or more coats) Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

Each Each Each Each Each

69.05 63.10 60.45 26.20 16.65

Each One Square Metre. One Square Metre.

155.85 4.10 2.55

14.042 14.042.01 14.042.02 14.043

One Square Metre

3.20

14.044

One Square Metre

12.35

14.045 14.045.01 14.046

One Square Metre

14.90

One Square Metre

4.25

14.047 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture over and including a priming coat of ready mixed zinc chromate yellow primer on new work : 75 mm diameter pipes Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 75 mm diameter pipes Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with, aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work. 75 mm diameter pipes Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 75 mm diameter pipes 100 mm diameter pipes 150 mm diameter pipes Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) W all painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work.

14.047.01 14.048

One Square Metre

18.45

14.048.01 14.049

One Metre

11.20

14.049.01 14.050

One Metre

5.40

14.050.01 14.051

One Metre

12.15

14.051.01 14.051.02 14.051.03 14.052 14.052.01 14.053 14.053.01

One Metre One Metre One Metre

5.90 7.60 10.80

One Square Metre

9.90

One Square Metre

25.85

Page 64

DSR_2007

14.054 14.054.01 14.055 14.055.01 14.056 14.056.01 14.057 14.057.01 14.058 14.058.01 14.059 14.059.01 14.060 14.061 14.062 14.062.01 14.062.02 14.063

14.063.01 14.064 14.064.01

Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. Painting with aluminium paint of approved brand and manufacture to given an even shade. One or more coats on old work. Painting with acid proof paint of approved brand and manufacture of required colour to given an even shade : One or more coats on old work. Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to given an even shade : One or more coats on old work. French spirit polishing: One or more coats on old work. Polishing on wood work with ready made wax polish of approved brand and manufacture: Old work Re-lettering with black Japan paint of approved brand and manufacture. Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : 32 mm dia 40 mm dia Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer's specification. One or more coats on old work.

One Square Metre

22.85

One Square Metre

18.25

One Square Metre

21.05

One Square Metre One Square Metre

16.65 38.40

One Square Metre

18.25

per letter per centimetre height 0.55 One Square Metre 18.80

Each Each

33.75 34.90

One Square Metre

13.85

14.065 14.065.01 14.065.02 14.066 14.066.01 14.066.02 14.067 14.067.01 14.067.02 14.068

Finishing walls with water proofing cement paint of required shade : Old work (one or more coats applied @ 2.29 kg/10sqm) over priming coat of primer applied @ 0.80 litre / 10sqm complete including cost of priming coat. One square metre Finishing walls with textured exterior paint of required shade : Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr / 10sqm ) One Square Metre Old work ( One or more coats applied @ 1.82 ltr / 10sqm ). One square metre Finishing walls with Acrylic smooth exterior paint of required shade. Old work ( Two or more coats applied @1.67 ltr / 10sqm on existing cement paint surface ). Old work ( One or more coats applied @ 0.90 ltr / 10sqm ). Finishing walls with Premium Acrylic smooth exterior paint with Silicone additives of required shade. Old work ( Two or more coats applied @ 1.43 ltr / 10 sqm over existing cement paint surface ). Old work ( One or more coats applied @ 0.83 ltr / 10 sqm.) Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrisive bitumastic paint approved brand and manufacture on old work : 100mm diameter pipes. 150mm diameter pipes. Varnishing with varnish of approved brand and manufacture. One or more coats with copal varnish. One or more coats with spar varnish.

27.95

82.85 48.60

One Square Metre One Square metre

36.30 22.80

One Square Metre One Square Metre

46.60 29.45

14.068.01 14.068.02 14.069 14.069.01 14.069.02

One Square Metre One Square Metre One Square Metre One Square Metre

7.05 10.05 21.00 21.90

Page 65

DSR_2007

14.070 14.071 15.001

15.002

15.002.01 15.002.02 15.003

Melamine polishing on wood work ( one or more coats ). Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge. Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.: 1:3:6 or richer mix 1:4:8 or leaner mix

One Square Metre One Square Metre

45.15 18.90

One Cubic Metre

128.45

One Cubic Metre One Cubic Metre

368.45 226.90

Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. One Cubic Metre 15.004 Demolishing R.B. work manually / by mechanical means including stacking of steel bars and disposal of unsericeable material within 50 metres lead as per direction of Engineer-in-charge.. One Cubic Metre Extra for cutting reinforcement bars manually / by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-incharge. One Square Metre Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. One Kg Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.: In mud mortar In lime mortar with old mughal bricks In lime mortar In cement mortar Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured): From brick work in mud mortar From brick work in lime mortar From brick work in cement mortar Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In lime mortar In cement mortar

537.55

479.85

15.005

176.35 1.45

15.006 15.007

15.007.01 15.007.02 15.007.03 15.007.04 15.008

One One One One

Cubic Cubic Cubic Cubic

Metre Metre Metre Metre

106.45 268.25 128.45 310.75

15.008.01 15.008.02 15.008.03 15.009

1000 nos 1000 nos 1000 nos

696.25 801.80 998.80

15.009.01 15.009.02 15.010

One Cubic Metre One Cubic Metre

175.05 370.75

15.010.01 15.010.02 15.011

Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.: In lime mortar One Cubic Metre In cement mortar One Cubic Metre Removing mortar from stones and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) In lime mortar One Cubic Metre

221.55 433.60

15.011.01

71.65

Page 66

DSR_2007

15.011.02 15.012

15.012.01 15.012.02 15.013 15.013.01 15.013.02 15.014

15.014.01 15.014.02 15.015

In cement mortar Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq.metres and below Of area beyond 3 sq.metres Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below Of area beyond 3 sq.metres Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above Of sectional area below 40 square centimetres

One Cubic Metre

103.55

Each Each

54.60 75.35

Each Each

21.40 28.25

One Cubic Metre One Metre

658.65 2.65

15.015.01 15.015.02 15.016

Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres: Of sectional area 40 square centimetres and above One Cubic Metre per metre span 95.55 Of sectional area below 40 square centimetres One Metre per metre span 0.25 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres: Of sectional area 40 square centimetres and above Of sectional area below 40 square centimetres Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in : R. S. Joists Channels, angles, tees and flats Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dimembering and stacking within 50 metres lead. Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge..

15.016.01 15.016.02 15.017 15.017.01 15.017.02 15.018

One Cubic Metre per metre height 135.20 One Metre per metre height 0.50

One Kg One Kg

0.50 0.35

One Kg

0.85

15.019

One Kg

0.60

15.020 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres. One Kg per metre span. .15 0 15.021 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. Extra for making of structural steel work required to be reerected. Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm For thickness of tiles above 25 mm and upto 40 mm Demolishing dry brick pitching in floors, drains etc. including stacking serviceable material and disposal of unserviceable material within 50 metres lead. Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. One Kg per metre height 0.15 One Kg 0.65

15.022 15.023 15.023.01 15.023.02 15.024

One Square Metre One Square Metre

10.90 16.60

One Cubic Metre

199.55

15.025

One Square Metre

40.50

15.026

One Square Metre

15.45

Page 67

DSR_2007

15.027 15.028 15.028.01 15.028.02 15.029

15.030

15.031

15.032

15.033 15.034

15.034.01 15.034.02 15.035

15.036 15.037 15.038

15.039

15.039.01 15.039.02 15.039.03 15.040 15.040.01 15.040.02 15.041

15.042 15.042.01 15.042.02 15.042.03

Demolishing mud phaska in terracing and disposal of material within 50 metres lead Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of : G. S. Sheet Asbestos sheet Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Demolishing thatch roofing including mats, bamboo, jaffari etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Dismantling wooden ballies in posts and struts including stacking within 50 metres lead. Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : 'T' or 'L' iron or pipe R. C. C. Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead. Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. Dismantling expanded metal or I. R. C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead: Upto 10 mm thick Thickness above 10 mm upto 25 mm Thickness above 25 mm upto 40 mm Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead: Thickness upto 40 mm Thickness above 40 mm upto 75 mm Dismantling cement asbestos, or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead. 75 to 80 mm dia pipe. 100 mm dia pipe 150 mm dia pipe

One Cubic Metre

137.90

One Square Metre One Square Metre

24.70 11.75

One Cubic Metre

405.25

One Square Metre

38.65

One Square Metre

32.05

One Square Metre One Metre

8.90 3.15

Each Each

44.85 53.05

Each One Kg One Square Metre

4.85 5.55 9.80

One Square Metre

11.55

One Square Metre One Square Metre One Square Metre

9.35 11.95 14.25

One Square Metre One Square Metre

44.10 66.05

One Square Metre

8.60

One Metre One Metre One Metre

11.40 11.80 12.20

Page 68

DSR_2007

15.043 Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.: W ater bound macadam road Bituminous road Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge: 15 mm to 40 mm nominal bore Above 40 mm nominal bore Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually / by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pies, and lead at site within 50 metre lead as per direction of Engineer-in-charge.: Upto 150 mm diameter Above 150 mm dia upto 300 mm dia. Above 300 mm diameter Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pies, manually / by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes, & lead at site within 50 metres lead as per direction of Engineer-in-charge.: Upto 600 mm diameter Above 600 mm diameter Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually / by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge.: Upto 150 mm diameter Above 150 mm diameter Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge.. Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead. Dismantling of road gully chambers of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. Dismantling of flushing cistern of any size including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres.

15.043.01 15.043.02 15.044

One Square Metre One Square Metre

34.30 66.30

15.044.01 15.044.02 15.045

One Metre One Metre

24.90 29.05

15.045.01 15.045.02 15.045.03 15.046

One Metre One Metre One Metre

63.45 86.00 113.20

15.046.01 15.046.02 15.047

One Metre One Metre

113.20 279.20

15.047.01 15.047.02 15.048

One Metre One Metre

49.85 60.65

Each

110.35

15.049

Each

65.05

15.050

Each

711.50

15.051

Each

149.50

15.052

Each

143.35

15.053

Page 69

DSR_2007

15.053.01 15.053.02 15.054 15.055

Upto 150 mm diameter Above 150 mm diameter Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead: 120 x 120 cm (outside to outside) 210 x 120 cm ( outside to outside ) 320 x 120 cm ( outside to outside ) Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus materials and stacking of serviceable material within 50 metre lead as directed by Engineer-in-Charge.

Each Each Each

52.70 178.50 105.70

15.055.01 15.055.02 15.055.03 15.056

Each Each Each

166.60 255.65 361.65

One Square Metre

8.20

15.057

One Square Metre

8.65

15.058 Demolishing C.C / RCC work by mechanical means and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000m, stacking serviceable and unserviceable material separately including cutting reinforcement bars. One Cubic Metre. Dismantling of flexibe pavement ( bituminous courses ) by mechanical means and disposal of dismantled material upto a lead of 1000 metres, as per direction of Engineer-in-charge. One Cubic Metre. Preparation and consolidation of subgrade with power road roller of 8 to 12 tonne capacigty after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. One Square Metre Extra for compaction of earth work in embankment under optimum moisture conditions to give atleast 95% of the maximum dry density ( proctor density ). One Square Metre W ith F.P.S. bricks. One Square Metre Supplying and stacking at site . 90 mm to 45 mm size stone aggregate. One Cubic Metre 63 mm to 45 mm size stone aggregate. One Cubic Metre 53 mm to 22.4 mm size stone aggregate. One Cubic Metre Over burnt (Jhana) brick aggregate 120mm to 40mm. One Cubic Metre Over burnt (Jhana) brick aggregate 90mm to 45mm. One Cubic Metre Stone screening 13.2 mm nominal size ( Type A ). One Cubic Metre Stone screening 11.2 mm nominal size ( Type B ). One Cubic Metre Red bajri. One Cubic Metre Good earth. One Cubic Metre Moorum One Cubic Metre Laying spreading and compacting stone aggregate of specified sizes to W BM specifications including spreading in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8 - 10 tonne in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate watering and compacting to the required density. One Cubic Metre

731.05

15.059

106.20

16.001

33.90

16.002

16.002.01 16.003 16.003.01 16.003.02 16.003.03 16.003.04 16.003.05 16.003.06 16.003.07 16.003.08 16.003.09 16.003.10 16.004

4.50 255.60 742.30 768.45 810.55 398.20 438.85 892.25 979.40 654.15 144.05 421.85

192.55

Page 70

DSR_2007

16.005

16.005.01 16.005.02 16.006

Laying water bound macadam sub-base with brick aggregate and blinding material, earth etc., including screening, sorting and spreading to template and consolidation with light power road-roller etc., complete. ( payment for brick aggregate and moorum etc., to be made separately ). Over burnt ( Jhama ) brick aggregate 120 mm to 40 mm. One Cubic Metre Over burnt ( Jhama ) brick aggregate 90 mm to 45 mm. One Cubic Metre Supplying, stacking and spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling. W ith road roller / hand roller. One Cubic Metre Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. W ith F.P.S. bricks of class designation 75 One Metre Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. W ith F.P.S. bricks of class designation 75 One Metre Scarifying metalled (water-bound) road surface including disposal of rubbish lead upto 50 m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. Making bajri path including preparation of subgrade, supplying and laying brick aggregate of 50 mm nominal size 7.5 cm deep with blinding material consisting of 12 mm moorum and 12 mmmoorum and 12mm red bajri consolidated with road roller. Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete. W ith F.P.S. bricks of class designation 75 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. Bituminous portion W ater bound macadam. Cutting bajri paths and making good the same including supply of extra quantities of brick aggregate, moorum and red bajri required. Supplying at site.

136.20 136.20

16.006.01 16.007

6.70

16.007.01 16.008

52.35

16.008.01 16.009

14.90

One Square Metre

6.45

16.010

One Square Metre One Square Metre

69.95 211.10

16.011 16.012 16.012.01 16.013

One Square Metre

183.55

16.013.01 16.013.02 16.014

One Cubic Metre One Cubic Metre

1081.80 572.45

One Square Metre

53.25

16.015 16.015.01

R.C.C. Standards post / Struts / rails / poles of mix 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size ) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge ( cost of earth works in excavation, concrete works in foundation to be paid separately ). One Cubic Metre 16.015.02 W elded steel wire fabric of required width rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer ( priming & painting to be paid for separately ). Supplying and fixing turn buckles and straining bolts for barbed wire fencing.

11547.90

One Kilogram Each set

46.50 88.15

16.016

Page 71

DSR_2007

16.017 Fencing with RCC post placed at required distance, embedded in cement cncrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire 9.38 kg per 100 metres (min) between the two posts fitted and fixed with GI staples on wooden plugs or GI kbinding wire tied to 6mm bar nibs fixed while casting the post (cost of RCC posts, struts, earth work and concrete to be paid for separately).: Payment to be made per metre cost of total length of barbed wire used. W ith GI barbed wire.

16.017.01 16.018

One Metre

5.85

16.018.01 16.019

Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwovn with horizontal wires, of barbed wire 9.38 kg per 100 m (minimum) between the two posts fitted and fixed with GI staples, turn buckles etc., complete. (Cost of posts, struts, earth work and concrete work to be paid for separately) : Payment to be made per metre cost of total length of barbd wire used. W ith GI barbed wire. One Metre Supplying at site Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.

8.45

One Kg

43.35

16.020 W elded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and end corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with GI staples on wooden plugs or tied to 6mm bar nibs with GI binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately ). One Square Metre 11.50 Engraving letters in hard stone per cm. height per letter. 1.55 Providing and fixing 15 x 15 x 90 cm boundary stone of hard stone with top 30 cm chisel dressed on all four sides and on top (cost of excavation, refilling and concrete etc. to be paid for separately) Each Providing and fixing 15 cm dia at top, 20 cm at bottom and 90 cm high precast reinforced cement concrete 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) boundary stone as per standard design including finishing smooth with cement mortar 1:3 ( 1 cement : 3 fine sand ) ( cost of excavation, refilling and concreting to be paid for separately) Each Providing and fixing precast reinforced cement concrete 1:1.5:3 ( 1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) kilometre stone as per standard design including finishing smooth in 1:3 cement mortar ( 1 cement : 3 fine sand ) but excluding the cost of earth work, concrete in foundation, painting and lettering etc. which shall be paid for separately. 35 x 111 x 25 cm size Each

16.021 16.022

77.10

16.023

258.15

16.024

16.024.01

1094.45

Page 72

DSR_2007

16.024.02 16.024.03 16.025

50 x 152.5 x 25 cm size 35 x 93.5 x 18 cm size. Surface dressing on new surface with paving bitumen of grade A90 / S-90 of approved quality using 2.25 kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface including consolidation with road roller of 6 to 8 tonne capacity etc. complete: Surface dressing on new surface in two coats with bitumen of grade A-90 / S-90 of approved quality using 1.8 kg. of bitumen per sqm with 1.5 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface for first coat and 1.1 kg. of bitumen per sqm. with 1.00 cu. metre of stone chippings 11.2 mm nominal size per 100 sqm. of road surface for second coat including consolidation of each coat separately with road roller of 6 to 8 tonne capacity etc. complete: Surface dressing on old surface with hot bitumen of grade A-90 / S90 of approved quality using 1.95 kg of bitumen per sqm. with 1.50 cum of stone chippings 11.2 mm nominal size per 100 sqm. of road surface including consolidation with road roller of 6 to 8 tonne capacity, etc. complete: Surface dressing one coat on new surface with bitumen of specified grade at a rate of 1.95 kg / sqm. of surface area with 1.5 cum. of stone chippings 13.2 mm nominal size per 100 sqm. of road surface including consolidation with road roller of 6 to 8 tonne capacity, etc. complete: Using bitumen emulsion ( minimum 50% bitumen content - RS grade conforming to IS : 8887) Surface dressing one coat on old surface with bitumen of specified grade at the rate of 1.22 kg / sqm of surface area with 1.10 cum of stone chippings 11.2 mm nominal size per 100 sq.m. of road surface including consolidation with road roller of 6 to 8 tonne capacity etc. complete: Using bitumen emulsion ( minimum 50% bitumen content - RS grade conforming to IS : 8887 ) Providing and applying tack coat using hot straight run bitumen of grade 80 / 100 including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On W .B.M. @ 0.75 Kg / sqm. On bituminous surface @ 0.50 Kg / sqm.

Each Each

1565.50 740.20

One Square Metre

89.40

16.026

One Square Metre

121.15

16.027

One Square Metre

74.05

16.028

16.028.01 16.029

One Square Metre

70.10

16.029.01 16.030

One Square Metre

44.85

16.030.01 16.030.02 16.031

One Square Metre One Square Metre

23.90 17.15

16.031.01 16.031.02 16.032

Providing and applying tack coat using birumen emulsion (Rapid setting) complying with IS 8887-1995, spraying the bitumen emulsion with mechanically operated spray unit, cleaning and preparing the existing road surface as per specifications : On W BM @ 0.4 kg / sqm. One Square Metre On bituminous surface @ 0.25 kg / sqm. One Metre 2 cm premix carpet surfacing with 1.8 cu.m. and 0.90 cu.m. of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sq.m. and 52 kg. and 56 kg. of hot bitumen per cu.m. of stone chippings of 13.2 mm and 11.2 mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete : (tack coat to be paid separately):

18.00 12.35

Page 73

DSR_2007

16.032.01 16.032.02 16.032.3 16.033

16.033.01 16.033.02 16.033.03 16.034

16.035

W ith paving Asphalt 80 / 100 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. W ith paving Asphalt 60 / 70 with no solvent W ith Refinery Modified Bitumen CRMB 55 conforming to IRC : SP : 53 - 1999. 2.5 cm premix carpet surfacing with 2.25 cu.m and 1.12 cu.m. of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sq.m. and 52 kg. and 56 kg. of hot bitumen per cu.m. of stone chippings of 13.2 mm and 11.2 mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete: (tack coat to be paid for separately): W ith paving Asphalt 80 / 100 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. W ith paving Asphalt 60 / 70 with no solvent. W ith Refinery Modified Bitumen CRMB 55 conforming to IRC : SP : 53 - 1999. 2 cm premix carpet surfacing with 2.4 cu.m. of stone chippings 11.2 mm nominal size per 100 sq.m. and bitumen emulsion ( medium setting min. 65% bitumen content ) complying with IS: 8887-1995 using 96 kg per cu.m. of chippings including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately ). 2.5 cm premix carpet surfacing with 3 cu.m. of stone chippings 10 mm nominal size per 100 sq.m. and bitumen emulsion (medium setting min. 65% bitumen contents) complying with IS: 8887 - 1995 using 96 kg per cu.m. of chippings including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately ). Providing and laying bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade including required key aggregate as specified, spreading coarse aggregate with the help of self propelled / tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy. For 75 mm compacted thickness in two layers using stone aggregate of size 63.41 mm graded @ 0.90 cum per 10 sqm key aggregate of size 20.0 mm graded @ 0.18 cum per 10 sqm. W ith paving asphalt 80 / 100 @ 68 kg / 10 sqm. For 50mm compacted thickness using coarse aggregate of size 50 20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5mm graded @ 0.15 cum per 10 sqm. 25 mm thhick. 40 mm thick. 2.5 cm thick bitumastic sheet with hot bitumen of approved quality using stone chippings ( 60% 12.5 mm nominal size and 40% 10 mm nominal size ) @ 1.65 cum per 100 sq.m. and coarse sand at 1.65 cu.m. per 100 sq.m. of road surface and with bitumen @ 56 kg/cu.m. of stone chippings and at 128 kg/cu.m. of sand over a tack coat with hot straight run bitumen including consolidation with road roller of 8 to 10 tonne etc. complete ( tack coat to be paid separately ):

One Square Metre One Square Metre One Square Metre

81.95 81.00 87.80

One Square Metre One Square Metre One Square Metre

100.35 99.15 107.65

One Square Metre

81.95

One Square Metre

101.15

16.036

16.036.01

One Square Metre

311.60

16.036.01

16.037.01 16.037.02 16.038

One Square Metre. One Square Metre One Square Metre

219.75 493.45 789.50

Page 74

DSR_2007

16.038.01 16.038.02 16.038.03 16.039

16.039.01 16.039.02 16.039.03 16.040

W ith paving Asphalt 80 / 100 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. W ith paving asphalt 60 / 70 . W ith Refinery Modified Bitumen CRMB 55 conforming to IRC : SP : 53 - 1999. 4 cm thick bitumastic sheet with hot bitumen of approved quality using stone chippings ( 60% 12.5 mm nominal size and 40% 10 mm nominal size ) @ 2.60 cu.m. per 100 sq.m. and coarse sand at 2.60 cu.m. per 100 sq.m. of road surface and with bitumen @ 56 kg / cu.m of stone chippings and at 128 kg/cu.m. of sand over a tack coat with hot straight run bitumen including consolidation with road roller of 8 to 10 tonne etc. complete. ( tack coat to be paid separately ). W ith paving Asphalt 80 / 100 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. W ith paving asphalt 60 / 70 with no solvent. W ith Refinery Modified Bitumen CRMB 55 conforming to IRC : SP ; 53-1999. Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve ) with bitumen using 128 kg of bitumen of grade 80 / 100 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surfacing including rolling and finishing with road roller all complete.

One Square Metre One Square Metre One Square Metre

134.45 132.50 146.80

One Square Metre One Square Metre One Saure Metre

208.10 205.00 227.60

One Square Metre

36.85

16.041 Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg. of bitumen of grade 80 / 100 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size ( Passing 11.2 mm sieve and retained on 2.36 mm sieve ) per 100 sqm. of road surface including rolling and finishing with power road roller all complete. One Square Metre Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. One Cubic Metre Providing and laying design mix cement concrete in roads, taxi tracks and runways having a minimum works test beam flexural strength of 30 kg. per cum. at 28 days using not less than 340 Kg. of cement per cum of finished concrete, coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per specified design criteria approved by Engineer-in-Charge mechanically vibrated using needle and surface vibrators including steel form work with stury M.S. channel sections including curing and providing and filling construction joints and dummy joints with approved joint filler and primer including rounding of the edges and filling the grooves 10 x 25 mm deep at top for construction joints and 10 mm x 50 mm deep at top for dummy joints with joint sealing compound (conforming to grade B of IS:1834) including making necessary arrangements for expansion joints etc. all complete. One Cubic Metre 16.044 Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete. Providing and fixing in position premoulded joint filler in expansion joints. One Litre 33.70

50.00

16.042

3340.25

16.043

3692.40

16.045

per cm.depth per cm.width per m. length. 2.00

Page 75

DSR_2007

16.046 16.046.01 16.047

16.047.01 16.047.02 16.048

16.048.01 16.048.02 16.049

Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. Painting runway / ta xi track / apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-Charge including cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work ( Two or more coats ) Old work ( one or more coats Painting road surface marking with adequate no. of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white / yellow shade including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work ( Two or more coats ) Old work ( One or more coats ) Making bell mouth opening / entrance of size 100 x 50 x 50 cm for drainage pipe under footpath including providing cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) for shape of bell mouth including plastering providing and fixing 1precast RCC / SFRC slab including plastering with cement mortar 1:3 ( 1 cement : 3 fine sand ) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete.

per cm. depth per cm. width per m. length. 1.10

One Square Metre One Square Metre

70.15 43.10

One Square Metre One Square Metre

58.10 37.40

Each

1034.60

16.050 Providing and fixing Glow studs of size 100 x 20 mm made of heavy duty body shall be moulded ASA ( Acrylic styrene Acryloretrite ) or HIP ( High impact polystyrene ) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer-in-charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5 degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM 1 : 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. . Each Preparation of sub-base road pavement with commercial dry lime ( slaked ), fly ash stabilised soil with a mix of 3% lime, 12% fly ash and 85% local suitable soil by weight, so as to achieve minimum field C.B.R. of 20 including mixing, rolling with road roller curing etc. all complete. Minimum thickness 15 cm. One Cubic Metre Providing and fixing precast lime fly ash concrete blocks 1:2:3:6 ( 1 lime : 2 fly ash : 3 coarse sand : 6 stone aggregate 20 mm nominal size ) including finishing with 10 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand )in foot paths including preparation of sub grade with a hand rammer, laying 10 mm thick levelling course of fine sand ( jamuna sand ) and filling the joints with fine sand.

536.60

16.051

16.051.01 16.052

323.20

One Cubic Metre

3138.55

Page 76

DSR_2007

16.053

Providing and fixing concertina coil fencing with required dia 610mm (having 15nos. Round per 6 metre length) upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal RBT stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer-in-charge with reinforced barbed tape (RBT) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg / sqmm with tape (0.52mm thick) and weight 43.478gm / metre (cost of MS angle, CC blocks shall be paid separately). One Metre Providing and laying Dense Bituminous macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base / binding course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tippers to paver and laying the mixed material with paver finisher fitted with electronic sensing device to the required level and grade and rolling by road roller as per MORTH specificatgions, to achieve the desired density, but excluding the cost of primer / tack coat. 50 / 75 mm average compacted thickness with birumen of 60 / 70 grade @ 5% ( percentage by weight of total mix ) and lime filler @ 2% ( percentage by weight of aggregate ) One Cubic Metre Providing and laying Bituminous Macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base / binder course including loading of aggregate with FE loader, hot mixing of stone aggregate and birumen in hot mix plant, transporting the mixed material by tippers to paver and laying the mixed material with paver finisher fitted with electronic sensing device to the required level and grade and rolling with road rollers, as per MORTH specification to achieve the desired density and compaction but excluding the cost of primer / tack coat. 50 mm / 75 mm average compacted thickness with birumen of 60 / 70 grade @ 3.5% ( Percentage by weight of total mix ). One Cubic Metre Providing and lyaing Dense Bituminous concrete on prepared surface with specified graded stone aggregate for wearing course including loading of aggregate with FE loader, and hot mixing of bitumen with filler and stone aggregate to hot mix plant, transporting the mixed material by tippers to paver and laying the mixed material with mechanical paver finisher fitted with electronic sensing device to the required level and grade and rolling with road rollers, as per MORTH specification, to achieve the desired density and compaction but excluding cost of primer / tack coat. 40mm / 50 mm compacted thickness with bitumen of grade 60 / 70 @ 5.5% and lime @ 3% ( percentage by weight of total mix ). One Cubic Metre

180.25

16.054

16.054.01

5366.50

16.055

16.055.01 16.056

4242.20

16.056.01

5856.05

Page 77

DSR_2007

16.057 Providing and laying Dense Bituminous Concrete on prepared surface with specified graded stone aggregate for wearring course including loading of aggregate with FE loader, and hot mixing of bitumen with filler and stone aggregate in hot mix plant, transporting the mixed material by tippers to paver and laying the mixed material with mechanical paver finisher fitted with electronic sensing device to the required level and grade and rolling with road rollers, as per MORTH specifications, to achieve the desired density and compaction but excluding cost of primer / tack coat. 16.057.01 40 mm / 50 mm compacted thickness with bitumen of grade CRMB 60 @ 5.5% and lime @ 3% ( percentage by weight of total mix ). 16.058 Providing and laying Dense Bituminous Concrete on prepared surface with specified graded stone aggregate for wearring course including loading of aggregate with FE loader, and hot mixing of bitumen with filler and stone aggregate in hot mix plant, transporting the mixed material by tippers to paver and laying the mixed material with mechanical paver finisher fitted with electronic sensing device to the required level and grade and rolling with road rollers, as per MORTH specifications, to achieve the desired density and compaction but excluding cost of primer / tack coat. 40 mm / 50 mm compacted thickness with bitumen of grade PMB 40 @ 5.5% and lime @ 3% ( percentage by weight of total mix ). One Cubic Metre Manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc., as per IRC : 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-495601 and fixing the same with suitable sized aluminium alloy rivets @ 20cm c/c to back support frame of MS angle iron of size 25x25x3mm along with theft resistant measures, mounted and fixed with 2Nos. MS angles of size 35x35x5mm to a vertical post made up to MS Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angles, flats, providing & fixing MS message plate of required size steel work to be painted with two or morecoats of synthetic enamel paint of required shade and of a[[rpved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be pantd with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc., compete as per drawing, specification and direction of Engineer-in-charge. Mandatory / Regulatory sign boards of 900 mm dia-metre with part as length of 3750mm. One Square Metre Cautionary / W arning sign boards of equilateral triangular shape having each side of 900mm with support length of 3650mm. One Square Metre. One Cubic Metre 6323.40

16.058.01 16.059

6881.20

16.059.01 16.059.02

3776.45 2616.55

Page 78

DSR_2007

16.060 Manufacturing supplying and fixing retro reflective signage boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - III of ASTM-D 4956-01 as approved by Engineer-in-charge letters, borders etc., as per IRC : 67:2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class-II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge. ( Structural frame work including MS plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). . Overhead informatory road signage. One Square Metre Providing Retro-reflective regulatory sign board of size 900mm dia meter made out of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders etc., will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to MS frame of angle iron of size 40x40x4mm. The boards will be fixed to 1 No. 50x50mm square post made of MS angle 50x50x4m, 4m long welded to the frame with adequate antitheft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluiminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. One Square Metre 16.062 Providing and applying 2.5mm thick road marking strips (retroreflective) of specified shade / colour using hot thermoplastic material by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoeheater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc., complete as per direction of Engineer-in-charge and accordance with applicable specifications. One Square Metre 16.063 Providing and laying and mking kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc., complete and as per direction of Engineer-in-charge.

16.060.01 16.061

4017.75

4117.10

497.30

One Metre

198.80

Page 79

DSR_2007

16.064

Providing and laying 75mm thick compacted bed of dry brick aggregate of 40mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand including finishing smooth etc., complete as per direction of Engineer-incharge.

One Square Metre

63.15

16.065 Providing and fixing post delineators made of ABS round body fitted with 2Nos. 100mm dia. High reflective reflectors and mounted on MS pipe of 65mm dia. Duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge. Excavating holes upto 0.10 cum including getting out the excavated soil then returning thesoil as deported in layers not exceeding 20cm in depth including consolidating and deposited layer by ramming watering etc., Disposing of surplus excavated soil as directed within a lead of 50mm and lift upto 1.5m. Each All kinds of soil. Each Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50mm (HPL or equivalent) including reinforcement with 6mm dia MS bars 4 Nos. on each side including setting in position in footpath to the required level and line over a bed of 20mm average thick cement mortar (1 cement : 3 coarse sand ) having thickness not more than 5mm except on curve including filling of joints with same cement mortar and making grooves etc,. Complete as per direction of Engineer-in-charge. Providing and laying 60mm thhick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc., all complete as per the direction of Engineer-incharge. Providing and lahying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc., as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment) (Precast CC kerb stone shall be approved by Engineer-in-charge ). Providing and fixing GI chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of GI wire of dia 4mm. Made of GI wire of dia 4mm PVC coated to achieve outer dia not less than 5mm in required colour and shade. Providing and fixing GI chain link fabric fencing of required width in mesh size 25 x 25 mm made of GI wire of dia 3mm including strengthening with 2mm dia. W ire or nuts, bolts and washers as required complete a per the direction of Engineer-incharge. Supplying and stacking of hard stone (for stone pitching) 22.5cm thick at site.

16.066

16.066.01 16.067

786.35 10.85

One Square Metre

345.35

16.068

One Square Metre

346.35

16.069

OneCubic Metre

4247.70

16.070

16.070.01 16.070.02 16.071

One Square Metre One Square Metre

373.45 403.95

One Square Metre One Cubic Metre

464.95 458.35

16.072

Page 80

DSR_2007

16.073 Dry stone pitching 22.5cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20cm including preparing the bedding surface etc., all complete. (Payment for stone to be made separately). 75mm thick back filling for pitching including supplying of required materials and consolidation etc., complete with : Moorum Stone aggregate 20mm nominal size. Stone aggregate 40mm nominal size.

One Square Metre

96.60

16.074 16.074.01 16.074.02 16.074.03 16.075

One Square Metre One Square Metre One Square Metre

34.45 69.05 65.10

16.076 16.077

Providing and laying CC pavement of mix M25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc., complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). One Cubic Metre Deduct for using of M 20 grade concrete instead of M-25 grade concrete in CC pavement. One Cubic Metre Scarifying the existing bituminous road surface to a depth of 50mm and disposal of scarified material within all lifts and lead upto 1000 metre ( by mechanical means ). One Square Metre Providing and fixing water closet squatting pan ( Indian type W .C. pan ) with 100 mm sand cast iron P or S trap, 10 litre low level P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, Parryware/Hindware/ Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.

4471.25 147.30

2.60

17.001

17.001.01 17.001.02 17.002

W hite Vitreous Chine Orissa pattern W .C. pan of size 580 x 440 mm with integral type foot rests.. Stainless Steel AISI - 304 ( 18 / 8 ) Orissa pattern W C pan of size 585 x 480 mm with flush pipe and integrated type foot rests. Providing and fixing white vitreous china pedestal type water closet (European type W .C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, ) with all fittings and fixtures complete cutting and making good the walls and floors wherever required : W .C. pan with ISI marked white solid plastic seat and lid. W .C. pan with ISI marked black solid plastic seat and lid. Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white flushing cistern & CP flush bend with fittings & C.I. . brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W .C. pan with ISI marked white solid plastic seat and lid W .C. pan with ISI marked black solid plastic seat and lid.

Each Each

2304.65 5382.60

17.002.01 17.002.02 17.003

Each Each

2152.50 2123.45

17.003.01 17.003.02

Each Each

3282.95 3253.95

Page 81

DSR_2007

17.004 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre P.V.C. automatic flushing cistern . Range of two urinal basins with 5 litres white P.V.C. automatic flushing cistern . Range of three urinal basins with 10 litre P.V.C. automatic flushing cistern.. Range of four urinal basins with 10 litre P.V.C. automatic flushing cistern. Providing and fixing white vitreous china flat back half stall urinal of 580 x 380 x 350 mm with white PVC automatic flushing cistern with fittings, standard size C.P. brass flush pie, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, . with fittings, standard size G.I. flush pipe for back and front flush with standard spreader pipe with fittings, G.I. clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required: Single squatting plate with 5 litre P.V.C. automatic flushing cistern. Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern. Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern. Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern. Providing and fixing wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : W hite Vitreous China W ash basin size 630 x 450 mm with a pair of 15 mm C.P. brass pillar taps. W hite Vitreous China W ash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap. W hite Vitreous China W ash basin size 550 x 400 mm with a pair of 15 mm C.P. brass pillar taps W hite Vitreous China Flat back wash basin size 550 x 400 mm with single 15 mm C.P brass pillar tap. W hite Vitreous China Angle back wash basin size 600 x 480 mm with single 15 mm C.P. brass pillar tap.

17.004.01 17.004.02 17.004.03 17.004.04 17.005

Each Each Each Each

2018.70 3393.60 4491.60 6062.20

17.005.01 17.005.02 17.005.03 17.005.04 17.006

Each Each Each Each

3720.30 5960.75 7936.50 9811.40

17.006.01 Each Each Each Each 2392.55 3548.10 4732.40 5789.45 17.006.02 17.006.03 17.006.04 17.007

17.007.01 17.007.02 17.007.03 17.007.04 17.007.05

Each Each Each Each Each

1332.90 1201.70 1176.10 1044.90 1149.45

Page 82

DSR_2007

17.007.06 17.007.07 17.007.08

W hite single W hite single

Vitreous China Angle back wash basin size 400 x 400 mm with 15 mm C.P. brass pillar tap. Each Vitreous China Flat back wash basin size 450 x 300 mm with 15 mm C.P. brass pillar tap. Each

925.25 940.35

17.007.09

17.007.10 17.007.11

W hite Vitreous China Surgeon type wash basin of size 660 x 460 mm with pair of 15 mm C.P. brass pillar taps, with elbow operated levers. Each W hite Vitreous China Surgeon type wash basin of size 660 x 460 mm with single 15 mm C.P. brass pillar tap with elbow operated levers ISI marked. Each Salem Stainless Steel AISI - 304 ( 18 / 8 ) Round basin 405x345 mm with single 15 mm C.P. brass pillar tap. Each Salem Stainless Steel AISI - 304 ( 18 / 8 ). W ash basin 530 x 345 mm with single 15 mm C.P. brass pillar tap. Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: W hite glazed fire clay kitchen sink of size 600 x 450 x 250 mm Providing and fixing Stainless Steel A ISI 304 ( 18 / 8 ) kitchen sink as per IS 13983 with CI brackets and stainless stell plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board. 510 x 1040 mm bowl depth 250 mm. 510 x 1040 mm bowl depth 225 mm. 510 x 1040 mm bowl depth 200 mm. 510 x 1040 mm bowl depth 178 mm. Kitchen sink without drain board. 610 x 510 mm bowl depth 200 mm. 610 x 460 mm bowl depth 200 mm. 470 x 420 mm bowl depth 178 mm. Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40 mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required: Size 450 x 300 x 150 mm Size 600 x 450 x 200 mm Providing and fixing draining board with CI brackets including painting of brackets, cutting and making good the walls wherever required : W hite glazed fire clay draining board of size 600 x 450 x 25 mm. Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W .C. pan of size 580 mm Orissa pattern W .C. pan of size 580 x 440 mm W hite glazed fire clay draining board of size 600 x 450 x 25 mm Orissa pattern W C Pan 580 x 440 mm. Providing and fixing white vitreous china pedestal type ( European type / wash down type ) water closet pan.

2274.85

1803.35 2264.45

Each

2090.25

17.008

Each

705.90

17.009

17.009.01 17.010

Each

1793.35

17.010.01 17.010.01.01 17.010.01.02 17.010.01.03 17.010.01.04 17.010.02 17.010.02.01 17.010.02.02 17.010.02.03 17.011

Each Each Each Each Each Each Each

6154.35 5805.90 5225.15 3482.90 3439.20 3206.90 2161.55

17.011.01 17.011.02 17.012

Each Each

1446.10 2300.95

17.012.01 17.013 17.013.01 17.013.02 17.014 17.014.01 17.015

Each

638.60

Each Each Each Each

534.60 1010.85 398.40 841.25

Page 83

DSR_2007

17.016

17.017 17.017.01 17.017.02 17.018

17.018.01 17.018.02 17.019 17.019.01 17.019.02 17.020 17.020.01 17.020.02 17.021

17.022 17.023

17.024 17.025 17.025.01 17.025.02 17.025.03 17.025.04 17.025.05 17.025.06 17.026 17.026.01 17.027 17.027.01 17.027.02 17.028 17.028.01 17.028.01.01 17.028.01.02 17.028.02 17.028.02.01 17.028.02.02 17.029 17.030

Extra for using coloured pedestal type W C pan ( European type ) with low level cistern of same colour instead of white vitreous chine W C Pan and Cistern. Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 250 x 130 x 30 mm 250 x 125 x 25 mm Providing and fixing PVC low level flushing cistern with manually controlled device ( handle lever ) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity. - W hite. 10 litre capacity - Coloured. Providing and fixing controlled flush, low level cistern made of vitreous chine with all fittings complete. 10 litre ( full flush ) capacity - W hite. 10 litre ( full flush ) capacity - coloured, Providing and fixing solid plastic seat with lid for pedestal type W .C. pan complete. W hite solid plastic seat with lid Black solid plastic seat with lid Extra for providing coloured other than black solid PVC plastic seat and cover in European type W C pan instead of white plastic seat and cover. Providing and fixing G.I. inlet connection for flush pipe connecting with W .C. pan. Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively. Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 630 x 450 mm. Flat back wash basin of size 550 x 400 mm. Angle back wash basin of size 600 x 480 mm. Angle back wash basin of size 400 x 400 mm. Flat back wash basin of size 450 x 300 mm. Surgeon type wash basin of size 660 x 460 mm. Providing and fixing kitchen sink including making all connections excluding cost of fittings. W hite glazed fire clay sink of size 600 x 450 x 250 mm. Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 450 x 300 x 150 mm. Size 600 x 450 x 200 mm. Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe. 32 mm dia. 40 mm dia. Flexible pipe. 32 mm dia. 40 mm dia. Providing and fixing 100 mm sand cast iron grating for gully trap. Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

Each

876.95

Each Each

111.70 112.85

Each Each

1178.80 783.85

Each Each

1178.80 1665.45

Each Each

334.95 305.90

Each Each

121.95 73.60

Each Each

578.95 1069.65

Each Each Each Each Each Each

753.00 596.20 700.75 476.55 491.65 1014.35

Each

1444.00

Each Each

830.75 1685.60

Each Each Each Each Each Each

42.15 47.95 46.80 49.10 16.45 28.85

Page 84

DSR_2007

17.031

Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each Providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia. Rectangular shape 453 x 357 mm. Oval shape 450 x 350 mm ( outer dimensions ) Rectangular shape 1500 x 450 mm. Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete. Providing and fixing toilet paper holder : C.P. brass Vitreous china Providing and fixing soil, waste and vent pipes: 100 mm dia Sand cast iron S&S pipe Centrifugally cast (spun) iron soxketed pipe as per IS: 3989. 75 mm diameter Sand cast iron S&S pipe as per IS: 1729. Centrifugally cast (spun) iron socketed pipe as per IS: 3989. Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 (1cement : 2 fine sand) in SCI / CI pipes. 75 mm dia pipe. 100 mm dia pipe. Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron / cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including cost of cutting holes and making good the walls etc. For 100 mm dia. pipe For 75 mm dia. pipe Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nuts complete : 100 mm Sand cast iron S&S as per IS - 1729 Sand cast iron S&S as per IS - 3989 75 mm dia Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing plain bend of required degree : 100 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS 3989. Providing and fixing heel rest sanitary bend 100 mm dia Sand cast iron S&S as per IS - 1729.

493.65

17.032

17.032.01 17.032.02 17.032.03 17.032.04 17.033

Each Each Each Each

599.15 465.10 504.00 1034.50

Each Each Each

218.80 147.10 173.00

17.034 17.034.01 17.034.02 17.035 17.035.01 17.035.01.01 17.035.01.02 17.035.02 17.035.02.01 17.035.02.02 17.036 17.036.01 17.036.02 17.037

One Metre One Metre One Metre One Metre

451.00 730.40 395.45 629.85

Each Each

25.30 29.80

17.037.01 17.037.02 17.038 17.038.01 17.038.01.01 17.038.01.02 17.038.02 17.038.02.01 17.038.02.02 17.039 17.039.01 17.039.01.01 17.039.01.02 17.039.02 17.039.02.01 17.039.02.02 17.040 17.040.01 17.040.01.01

Each Each

65.35 63.00

Each Each Each Each

255.00 291.00 210.00 230.90

Each Each Each Each

222.45 236.40 175.15 178.65

Each

244.50

Page 85

DSR_2007

Sand cast iron S&S as per IS - 3989. 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron pipe S&S as per IS - 3989. Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 x 100 x 100 x 100 mm 17.041.01 17.041.01.01 Sand cast iron S&S as per IS - 1729. 17.041.01.02 Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 x 75 mm 17.041.02 17.041.02.01 Sand cast iron S&S as per IS - 1729. 17.04102.02 Sand cast iron S&S as per IS - 3989. 17.042 Providing and fixing double equal plain junction of required degree. 100 x 100 x 100 x 100 mm 17.042.01 17.042.01.01 Sand cast iron S&S as per IS - 1729. 17.042.01.02 Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 x 75 mm 17.042.02 17.042.02.01 Sand cast iron S&S as per IS - 1729. 17.042.02.02 Centrifugally cast(spun) iron S&S Providing and fixing single equal plain junction of required degree 17.043 with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 x 100 x 100 mm 17.043.01 17.043.01.01 Sand cast iron S&S as per IS - 1729. 17.043.01.02 Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 mm 17.043.02 17.043.02.01 Sand cast iron S&S as per IS - 1729. 17.043.02.02 Sand cast iron S&S as per IS 3989. 17.044 Providing and fixing single equal plain junction of required degree : 100 x 100 x 100 mm 17.044.01 17.044.01.01 Sand cast iron S&S as per IS - 1729. 17.044.01.02 Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 mm 17.044.02 17.044.02.01 Sand cast iron S&S as per IS - 1729. 17.044.02.02 Sand cast iron S&S as per IS - 3989. Providing and fixing double unequal junction of required degree with 17.045 access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 x 100 x 75 x 75 mm 17.045.01 17.045.01.01 Sand cast iron S&S as per IS - 1729. 17.045.01.02 Sand cast iron S&S as per IS - 3989. 17.046 Providing and fixing double unequal plain junction of required degree: 100 x 100 x 75 x 75 mm 17.046.01 17.046.01.01 Sand cast iron S&S as per IS - 1729. 17.046.01.02 Sand cast iron S&S as per IS - 3989. Providing and fixing single unequal junction of required degree with 17.047 access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 x 100 x 75 mm 17.047.01 17.047.01.01 Sand cast iron S&S as per IS - 1729. 17.047.01.02 CSand cast iron S&S as per IS - 3989. 17.040.01.02 17.040.02 17.040.02.01 17.040.02.02 17.041

Each Each Each

286.35 204.20 249.50

Each Each Each Each

513.85 612.55 409.75 487.60

Each Each Each Each

473.35 558.15 356.35 445.75

Each Each Each Each

374.60 489.60 283.15 364.45

Each Each Each Each

323.50 442.00 250.65 333.10

Each Each

555.80 842.70

Each Each

507.00 757.90

Each Each

402.50 637.10

Page 86

DSR_2007

17.048 17.048.01 17.048.01.01 17.048.01.02 17.049 17.049.01 17.049.01.01 17.049.01.02 17.049.02 17.049.02.01 17.049.02.02 17.050 17.050.01 17.050.01.01 17.050.01.02 17.050.02 17.050.02.01 17.050.02.02 17.051 17.051.01 17.051.01.02 17.051.1.01 17.052 17.052.01 17.052.01.01 17.052.01.02 17.053 17.053.01 17.053.01.01 17.053.01.02 17.053.02 17.053.02.01 17.053.02.02 17.053.03 17.053.03.01 17.053.03.02 17.054 17.054.01 17.054.01.01 17.054.02 17.054.02.01 17.054.02.02 17.055 17.055.01 17.055.01.01 17.055.01.02 17.055.02 17.055.02.01 17.055.02.02 17.056 Providing and fixing single unequal plain junction of required degree : 100 x 100 x 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing double equal plain invert branch of required degree : 100 x 100 x 100 x 100 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 x 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing single equal plain invert branch of required degree : 100 x 100 x 100 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. 75 x 75 x 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing double unequal invert branch of required degree : 100 x 100 x 75 x 75 mm Sand cast iron S&S as per IS - 3989. Sand cast iron S&S as per IS - 1729. Providing and fixing single unequal plain invert branch of required degree : 100 x 100 x 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing sand cast iron S&S off sets as per IS : 1729. 76 mm off sets W ith 75 mm dia. pipe W ith 100 mm dia. pipe 114 mm off sets W ith 75 mm dia. pipe W ith 100 mm dia. pipe 152 mm off sets W ith 75 mm dia. pipe W ith 100 mm dia. pipe Providing and fixing sand cast iron S&S off sets as per IS : 3989. 75mm off sets. W ith 75 mm dia pipe. 150mm off sets. 610 x 460 bowl depth 178 mm W ith 100 mm dia pipe. Providing and fixing door piece, insertion rubber washer 3 mm thick, bolts & nuts complete : 100 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing terminal guard :

Each Each

350.20 551.15

Each Each Each Each

505.85 496.55 377.25 400.50

Each Each Each Each

388.55 393.20 290.15 299.45

Each Each

682.40 547.70

Each Each

459.40 505.85

Each Each Each Each Each Each

158.90 268.05 271.25 351.40 340.25 440.15

Each Each Each

220.45 277.75 374.15

Each Each Each Each

367.65 296.80 268.05 227.40

Page 87

DSR_2007

17.056.01 17.056.01.01 17.056.01.02 17.056.02 17.056.02.01 17.056.02.02 17.057 17.057.01 17.057.01.01 17.057.01.02 17.057.02 17.057.02.01 17.057.02.02 17.058 17.058.01 17.058.02 17.058.03 17.059 17.059.01 17.059.02 17.059.03 17.060

17.060.01 17.060.01.01. 17.060.01.02 17.060.02 17.060.02.01 17.060.02.02 17.061

17.061.01 17.061.02 17.061.03 17.062

100 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing and fixing collar : 100 mm Sand cast iron S&S Sand cast iron S&S as per IS - 3989. 75 mm Sand cast iron S&S as per IS - 1729. Sand cast iron S&S as per IS - 3989. Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm 75 mm 50 mm Providing and fixing M.S. stays and clamps for sand cast iron / centrifugally cast (spun) iron pipes of diameter : 100 mm 75 mm 50 mm Providing and fixing trap of of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS : 3989. Sand cast iron S&S as per IS : 3989. 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS : 3989. Sand cast iron S&S as per IS : 1729 Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand). 100 mm dia 75 mm dia 50 mm dia Painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer ( of approved quality ) on the outside surface of the cister flush pipe, other fittings, etc. complete for new work. Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W .C. pan with acid wherever necessary. Repainting CI cistern with synthetic enamel paint of approved colour brand and manufactureon the outside surface of cistern flush pipe, other fittings etc., complete.

Each Each Each Each

192.25 194.60 139.15 177.45

Each Each Each Each

143.45 202.70 107.80 146.10

Each Each Each

126.50 107.80 86.60

Each Each Each

48.25 41.55 34.25

Each Each Each Each

544.30 442.10 573.35 375.90

One Metre One Metre One Metre

152.45 108.85 68.40

Each

215.15

17.063

Each

146.55

17.064

Each.

65.75

Page 88

DSR_2007

17.065

17.065.01 17.065.02 17.066

17.066.01 17.066.02 17.067 17.068

Painting sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work: 100 mm diameter pipe 75 mm diameter pipe Repainting sand cast iron / centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. 100 mm diameter pipe 75 mm diameter pipe Repainting bath tub of size 1700 x 730 x 430 mm with enamel paint. Providing and Fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W .C. pan) with seat lid with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend 20 mm overflor pipe with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W hite vitreous china dual purpose W C pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. Providing and fixing PTMT W aste Coupling for wash basin and sink, of approved quality and colour. W aste coupling 31 mm of 79 mm length and 62 mm breadth weighing not less than 45 gms. W aste coupling 38 mm of 83 mm length and 77 mm breadth, weighing not less than 60 gms. Providing and fixing PTMT Bottle Trap for W ash Basin and sink Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 265 mm from the centre of the waste coupling 77mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. Providing and fixing PTMT liquid soap container 109 mm wide 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms. Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour . 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. 600 mm long towel rail with total length of 645 mm width 78mm and effective height of 88 mm, weighing not less than 190 gms.

One Metre One Metre

18.60 14.25

One Metre One Metre Each

9.30 7.00 208.45

17.068.01

Each

4142.20

17.069 17.069.01 17.069.02 17.070 17.070.01

Each Each

75.80 100.20

Each

366.20

17.070.02

Each

395.25

17.071

Each

164.65

17.072

Each

149.00

17.073

17.073.01 17.073.02

Each Each

294.65 329.50

Page 89

DSR_2007

17.074

17.075

17.076 17.076.01 17.077

17.077.01 17.077.02 17.077.03 18.001

18.001.01 18.001.02 18.001.03 18.001.04 18.001.05 18.001.06 18.002

Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour , weighing not less than 300 gms. Providing and fixing PTMT 15 mm Urinal spreader size 95 x 69 x 100 mm with 1/2" BSP thread and shapes weighing not less than 60 gms. Providing and fixing PTMT urinal cock of approved quality and colour . 15 mm nominal size 80 mm long, 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms. Providing and fixing MS holder bat clamp of approved design to sand cast iron / cast iron (spun) pipes comprising of MS flat brackets made of 50 x 5 mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4Nos. 6mm dia. Expansion hold fasteners incuding drilling necessary holes in brick wall / CC / RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x 1.6mm galvanised MS flats of specified shape and of total length 420mm and shall be fixed with MS nuts, bolts, & washers of size 25 x 6mm one bolt on each side of the pipe. Total bracket length 580 mm of approved shape and design ( for single 100mm dia pipe ). Total bracket length 810mm of approved shape and design ( for two 100 mm dia pipes ). Total bracket length 1040mm of approved shape and design ( for three 100 mm dia pipes ). Providing and fixing Polyethelene-Aluminium - Polyethelene (PE-ALPE) Compsite Pressure Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature upto 80 degree C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required ) eg. Elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal work - Exposed on wall. 1216 ( 16 mm OD ) pipe. 1620 ( 20 mmm OD ) pipe. 2025 (25 mm OD) pipe. 2532 ( 32 mm OD ) pipe. 3240 ( 40 mm OD ) pipe. 4050 ( 50 mm OD ) pipe.

Each

370.15

Each

147.25

Each

113.90

MR Each Each Each 121.70 148.05 174.35

One One One One One One

Metre Metre Metre Metre Metre Metre.

146.65 176.45 222.85 297.50 391.30 507.60

18.002.01 18.002.02

Providing and fixing Polyethelene-Aluminiump- Polyethelene (PE-ALPE) Compsite Pressure Pipes conforming to IS - 15450 U.V. stabilized with carbon black having thermal stability forhot & cold water supply, capable to withstand temperature upto 80 degree C including all special fittings of composite material (engineering plastic bend and brass inserts wherever required ) eg. Elbows, tees, reducers, couplers & connectors etc. with clamps at 1.00 metre spacing. This includes the cost of cutting chases and including testing of joints complete as per direction of the engineer-in-charge. Concealed work including cutting chases and making good the walls etc. 1216 ( 16 mm OD ) pipe. One Metre 1620 ( 20 mm OD ) pipe. One Metre

224.25 260.85

Page 90

DSR_2007

18.002.03 18.002.04 18.003

2025 ( 25 mm OD ) pipe. 2532 (32 mm OD) pipe. Providing and fixing Polyethelene-Aluminiump- Polyethelene (PE-ALPE) Compsite Pressure Pipes conforming to IS - 15450 - 2004 U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature upto 80 degree C including all special fittings of composite material (engineering plastic bend and brass inserts wherever required ) eg. Elbows, tees, reducers, couplers & connectors etc. with trenching, refilling and testing of joints complete as per direction of the engineer-in-charge. External work : 1216 ( 16 mm OD ) piple. 1620 ( 20 mm OD ) pipe. 2025 ( 25 mm OD ) pipe. 2532 ( 32 mm OD ) pipe. 3240 ( 40 mm OD ) pipe. 4050 ( 50 mm OD ) pipe. Providing and fixing 3 layer PP-R ( Poly Propylene Random copolymer ) pipes SDR 7.4 U V stabilized & anti - microbialfusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-charge. Internal work - Exposed on wall. PN - 16 Pipe, 16 mm OD PN - 16 Pipe, 20 mm OD PN - 16 Pipe, 25 mm OD PN - 16 Pipe, 32 mm OD PN - 16 Pipe, 40 mm OD PN - 16 Pipe, 50 mm OD Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall. 15 mm dia. nominal bore 20 mm dia. nominal bore 25 mm dia. nominal bore 32 mm dia. nominal bore 40 mm dia. nominal bore 50 mm dia. nominal bore Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore 20 mm dia nominal bore Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work): 15 mm dia. nominal bore 20 mm dia. nominal bore 25 mm dia. nominal bore 32 mm dia. nominal bore 40 mm dia. nominal bore 50 mm dia. nominal bore 65 mm dia. nominal bore. 80 mm dia. nominal bore

One Metre One Metre

319.80 413.30

18.003.01 18.003.02 18.003.03 18.003.04 18.003.05 18.003.06 18.004

One One One One One One

Metre Metre Metre Metre Metre Metre

143.95 171.10 214.90 284.35 371.50 487.75

18.004.01 18.004.02 18.004.03 18.004.04 18.004.05 18.004.06 18.010

One One One One One One

Metre. Metre. Metre. Metre. Metre. Metre

71.15 96.40 135.30 205.40 314.30 436.60

18.010.01 18.010.02 18.010.03 18.010.04 18.010.05 18.010.06 18.011 18.011.01 18.011.02 18.012 18.012.01 18.012.02 18.012.03 18.012.04 18.012.05 18.012.06 18.012.07 18.012.08

One One One One One One

Metre Metre Metre Metre Metre Metre

105.85 133.85 179.65 226.10 264.05 342.90

One Metre One Metre

144.75 170.15

One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre

94.05 116.60 156.85 193.60 219.60 280.10 356.15 458.15

Page 91

DSR_2007

18.013

18.013.01 18.013.02 18.014

Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete. 25 to 40 mm nominal bore 50 to 80 mm nominal bore Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately) Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 20 mm nominal bore Providing and fixing brass stop stock of approved quality : 15 mm nominal bore 20 mm nominal bore Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore 32 mm nominal bore. 40 mm nominal bore. 50 mm nominal bore 65 mm nominal bore 80 mm nominal bore Providing and fixing ball valve (brass) of approved quality complete, High or low pressure, with plastic floats complete : 15 mm nominal bore 20 mm nominal bore 25 mm nominal bore Providing and fixing gun metal non-return valve of approved quality (screwed end) 25 mm nominal bore Horizontal Vertical 32 mm nominal bore Horizontal Vertical 40 mm nominal bore Horizontal Vertical 50 mm nominal bore Horizontal Vertical 65 mm nominal bore Horizontal Vertical 80 mm nominal bore Horizontal Vertical Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main 15 mm nominal bore 20 mm nominal bore 25 mm nominal bore Providing and fixing uplasticised PVC connection pipe with brass unions: 30 cm length

Each Each

166.05 423.20

Each Each Each Each Each

121.90 191.70 235.20 191.70 235.20

18.015 18.015.01 18.015.02 18.016 18.016.01 18.016.02 18.017 18.017.01 18.017.02 18.017.03 18.017.04 18.017.05 18.017.06 18.018 18.018.01 18.018.02 18.018.03 18.019 18.019.01 18.019.01.01 18.019.01.02 18.019.02 18.019.02.01 18.019.02.02 18.019.03 18.019.03.01 18.019.03.02 18.019.04 18.019.04.01 18.019.04.02 18.019.05 18.019.05.01 18.019.05.02 18.019.06 18.019.06.01 18.019.06.02 18.020 18.020.01 18.020.02 18.020.03 18.021 18.021.01

Each Each Each Each Each Each

285.50 358.00 399.00 578.20 831.75 1369.25

Each Each Each

228.35 333.25 385.90

Each Each Each Each Each Each Each Each Each Each Each Each

292.15 317.70 371.45 464.40 494.95 605.30 738.20 847.40 1282.10 1467.95 1812.25 2390.70

Each Each Each

139.75 187.20 243.70

Page 92

DSR_2007

18.021.01.01 18.021.01.02 18.021.02 18.021.02.01 18.021.02.02 18.022 18.022.01 18.022.02 18.023 18.024

15 20 45 15 20

mm nominal mm nominal cm length mm nominal mm nominal

bore bore bore bore

Each Each Each Each

35.10 43.25 44.75 56.35

Providing and fixing C.P. brass shower rose with 15 or 20 mm hnlet. 100 mm diameter 150 mm diameter Laying in position centrifugally cast (spun) iron S&S or flanged pipes ( excluding cost of pipe ). Laying in position S&S or flanged C.I. special such as tees, bends, collars, tapers and caps etc. ( excluding cost of specials ). Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. ( Heavy class ). Upto 300 mm dia Over 300 mm dia Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable forflanged jointing as per IS: 1538. Upto 300 mm dia Over 300 mm dia Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536: 100 mm dia. pipe 125 mm dia. pipe 150 mm dia. pipe 200 mm dia. pipe 250 mm dia. pipe 300 mm dia. pipe 350 mm dia. pipe 400 mm dia. pipe 450 mm dia. pipe 500 mm dia. pipe 600 mm dia. pipe Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead: 100 mm diameter pipe 125 mm diameter pipe 150 mm diameter pipe. 200 mm diameter pipe 250 mm diameter pipe 300 mm diameter pipe 350 mm diametre pipe. 400 mm diametre pipe. 450 mm diametre pipe. 500 mm diametre pipe. 600 mm diametre pipe. Supplying pig lead at site of work Providing flanged joints to double flanged C.I. / D.I. pipes and specials including testing of joints. 80 mm diameter pipe 100 mm diameter pipe 125 mm diameter pipe

Each Each quintal

40.40 55.80 55.55

quintal

100.25

18.025 18.025.01 18.025.02 18.026

quintal quintal

2893.35 3119.85

18.026.01 18.026.02 18.027 18.027.01 18.027.02 18.027.03 18.027.04 18.027.05 18.027.06 18.027.07 18.027.08 18.027.09 18.027.10 18.027.11 18.028

quintal quintal

5123.45 5648.45

One One One One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

737.15 902.35 1066.65 1484.00 2106.80 2800.00 3455.55 4233.20 5065.65 6165.95 8149.40

18.028.01 18.028.02 18.028.03 18.028.04 18.028.05 18.028.06 18.028.07 18.028.08 18.028.09 18.028.10 18.028.11 18.029 18.030 18.030.01 18.030.02 18.030.03

Each Each Each Each Each Each Each Each Each Each Each quintal

82.25 120.45 123.30 163.45 204.20 246.35 256.00 232.10 371.60 393.70 528.40 6742.20

Each Each Each

65.60 113.00 114.15

Page 93

DSR_2007

18.030.04 18.030.05 18.030.06 18.030.07 18.030.08 18.030.09 18.030.10 18.030.11 18.030.12 18.031

18.031.01 18.031.01.01 18.031.01.02 18.031.02 18.031.02.01 18.031.02.02 18.031.03 18.031.03.01 18.031.03.02 18.031.04 18.031.04.01 18.031.04.02 18.031.05 18.031.05.01 18.031.05.02 18.031.06 18.031.06.01 18.031.06.02 18.032

18.032.01 18.033

150 mm diameter pipe 200 mm diameter pipe 250 mm diameter pipe 300 mm diameter pipe 350 mm diametre pipe. 400 mm diametre pipe. 450 mm diametre pipe. 500 mm diametre pipel. 600 mm diametre pipe. Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). 100 mm diameter Class I Class II 125 mm diameter Class I Class II 150 mm diameter Class I Class II 200 mm diameter Class I Class II 250 mm diameter Class I Class II 300 mm diameter Class I Class II Constructing masonry Chamber 30 x 30 x 50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for stop cock, with C.I. surface box 100 x 100 x 75 mm (Inside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks

Each Each Each Each Each Each Each Each Each

156.90 162.70 236.75 246.05 335.05 564.20 702.00 778.45 892.00

Each Each Each Each Each Each Each Each Each Each Each Each

2085.20 2550.45 3034.75 3163.60 3689.10 3889.75 6731.80 7221.20 10013.80 10240.90 12270.50 12718.30

Each

599.80

18.033.01

Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks Each

3595.30

Page 94

DSR_2007

18.034 Constructing masonry Chamber 90 x 90 x 100 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm, top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks Each Constructing masonry Chamber 120 x 120 x 100 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm, top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks Each Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) for fire hydrants, with C.I. surface box 350 x 350 mm, top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks Each Constructing masonry chamber 60 x 45 x 50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) for water meter complete with C.I. double flap surface box 400 x 200 x 200 mm. (inside) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. W ith F.P.S. bricks Each Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work. 15 mm diameter pipe. 20 mm diameter pipe. 25 mm diameter pipe. 32 mm diameter pipe. 40 mm diameter pipe. 50 mm diameter pipe.

18.034.01 18.035

6147.95

18.035.01 18.036

8528.75

18.036.01 18.037

3388.65

18.037.01 18.038

3366.00

18.038.01 18.038.02 18.038.03 18.038.04 18.038.05 18.038.06

One One One One One One

Metre Metre Metre Metre Metre Metre

4.65 5.45 7.20 8.50 10.10 11.80

Page 95

DSR_2007

18.039 18.039.01 18.039.02 18.039.03 18.039.04 18.039.05 18.039.06 18.040 18.040.01 18.040.02 18.040.03 18.040.04 18.040.05 18.040.06 18.040.07 18.040.08 18.041 18.041.01 18.041.02 18.041.03 18.041.04 18.041.05 18.041.06 18.041.07 18.041.08 18.041.09 18.041.10 18.042

18.042.01 18.042.02 18.042.03 18.043 18.044

Repainting G.I. pipes and fittings with synthetic enamel white paint of approved quality:: 15 mm diameter pipe. 20 mm diameter pipe. 25 mm diameter pipe 32 mm diameter pipe. 40 mm diameter pipe. 50 mm diameter pipe Painting G.I. pipes and fitting with two coats of anti- corrosive bitumastic paint of approved quality : 15 mm diameter pipes 20 mm diameter pipes 25 mm diameter pipes 32 mm diameter pipes 40 mm diameter pipes 50 mm diameter pipes 65 mm diameter pipes 80 mm diameter pipes Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work : 15 mm dia. pipe 20 mm dia. pipe. 25 mm dia. pipe. 32 mm dia. pipe. 40 mm dia. pipe. 50 mm dia. pipe. 65 mm dia. pipe. 80 mm dia. pipe. 100 mm dia. pipe. 150 mm dia. pipe. Boring with 100 mm diameter casing pipe for hand pump / tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the hand pipe / tube well is lowered and tested. Upto 6 metres depth. Beyond 6 m and upto 12 m depth Beyond 12 m and upto 18 m depth Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.

One One One One One One

Metre Metre Metre Metre Metre Metre

2.45 2.85 3.70 4.30 5.05 5.90

One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre

2.60 3.05 3.90 4.55 6.20 6.10 7.50 8.65

One One One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

21.95 22.25 22.85 23.40 23.70 24.60 38.85 40.00 42.40 63.15

One Metre One Metre One Metre One Metre

151.00 179.25 208.70 367.35

One Metre

209.00

18.045 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. 18.046 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 15 mm nominal bore 20 mm nominal bore 25 mm nominal bore 32 mm nominal bore. 40 mm nominal bore 50 mm nominal bore 65 mm nominal bore 80 mm nominal bore Each 576.80

18.046.01 18.046.02 18.046.03 18.046.04 18.046.05 18.046.06 18.046.07 18.046.08

Each Each Each Each Each Each Each Each

75.90 96.80 107.25 123.55 164.20 235.60 428.40 507.40

Page 96

DSR_2007

18.047

18.047.01 18.047.02 18.047.03 18.047.04 18.047.05 18.047.06 18.047.07 18.047.08 18.048

Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 15 mm nominal bore. 20 mm nominal bore. 25 mm nominal bore. 32 mm nominal bore 40 mm nominal bore. 50 mm nominal bore. 65 mm nominal bore. 80 mm nominal bore. Providing and placing on terrace ( at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. a) 15 mm nominal bore. Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. a) 15 mm nominal bore. Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore. Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. a) 15 mm nominal bore. Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 . a) 15 mm nominal bore. Providing and fixing P.T.M.T. bib cock of approved quality and colour.. 15 mm nominal bore 86 mm long, weighing not less than 88 gms.

Each Each Each Each Each Each Each Each

149.20 170.10 180.55 196.80 237.45 335.50 528.30 607.30

per litre

5.25

18.049

Each

313.10

18.050

Each

274.40

18.051

Each

315.80

18.052

Each

313.10

18.053

Each

347.65

18.054 18.054.01

Each Each

120.85 166.15 189.40 137.15

18.054.02 15 mm nominal bore, 122 mm long, weighing not less than 99 gms. 18.054.03 18.054.04 18.055 18.055.01 15 mm nominal bore, 86 mm long, weighing not less than 88 gms. 18.055.02 18.055.03 18.056 18.056.01 15 mm nominal size, 107 mm long, weighing not less than 110 gms. Each 185.25 20 mm nominal bore, 89 mm long. weiighing not less than 88 gms. Concealed stop cock, 15mm nominal bore, 108 mm long, weighing not less than 108 gms. Providing and fixing PTMT pillar cock of approved quality and colour. Each Each 148.75 195.20 Each 120.85 15 mm nominal bore, 165 mm long, weighing not less than 110 gms. Each 15 mm nominal bore, 90 mm long, weighing not less than 93 gms. Each Providing and fixing P.T.M.T. stop cock of approved quality and colour.

Page 97

DSR_2007

18.056.02 18.057 18.057.01 18.057.02 18.058

15 mm nominal bore, 125 mm long, foam flow, weighing not less than 120 gms Each Providing and fixing PTMT push cock of approved quality and colour . 15 mm nominal bore, 98 mm long, weighing not less than 75 gms. Each Each

266.55

113.90 96.45

15 mm nominal bore, 80 mm long, weighing not less than 46 gms. Providing and fixing PTMT grating of approved quality, colour and make ( Circular type 18.058.01 18.058.01.01 100 mm nominal dia 18.058.01.02 125 mm nominal dia., with 25 mm waste hole. Rectangular type with openable circular lid. 18.058.02 18.058.02.01 150mm nominal size square 100mm diameter of the inner hinged round grating. Providing and fixing C.I. double acting air valve of approved quality 18.059 with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately). 50 mm dia 18.059.01 80 mm dia 18.059.02 100 mm dia 18.059.03 Providing and fixing enclosed type water meter (bulk type) 18.060 conforming to IS:2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately). 80 mm dia nominal bore 18.060.01 100 mm dia nominal bore 18.060.02 150 mm dia nominal bore 18.060.03 200 mm dia nominal bore 18.060.04 Providing and fixing C.I. dirt box strainer for bulk type water meter 18.061 with nuts, bolts, rubber insertions etc. complete conforming to IS:2373 80 mm dia 18.061.01 100 mm dia 18.061.02 150 mm dia 18.061.03 200 mm dia 18.061.04 Providing and fixing PTMT Ball cock of approved quality, colour and 18.062 make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 18.062.01 15 mm nominal bore ,105 mm long weighing not less than 138 gms. 20m nominal size 125 mm long, 77 mm high and 42 mm wide with 18.062.02 piston travel or minimum 6.5 mm, having weight not less than 210gms. (100+40+70) (Body+Rod+Ball). Provided with leverage of minimum 310 mm and one piece moulded H.D. plastic ball of 127 mm dia. 18.062.03 25 mm nominal bore 152 mm long weighing not less than 440 gms. 18.062.04 40 mm nominal bore 242 mm long weighing not less than 690 gms. 50 mm nominal bore, 242 mm long, weighing not less than 1240 18.062.05 gms. Providing and fixing PTMT angle stop cock 15 mm nominal bore, 18.063 weighing not less than 85 gms. Providing and fixing PTMT swivelling shower, 15 mm nominal bore 18.064 weighing not less than 40 gms.

Each Each

39.70 46.65

Each

109.35

Each Each Each

3615.70 5276.65 6858.75

Each Each Each Each

2448.40 3719.80 5261.80 5914.55

Each Each Each Each

3110.45 4672.20 6067.85 8404.80

Each

165.60

Each Each Each Each Each Each

234.50 497.40 902.75 1338.30 148.75 101.95

Page 98

DSR_2007

18.065

18.066

18.066.01 18.066.02 18.067 18.067.01 18.067.02 18.068

Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 108 gms. Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc. suitable for flanged jointing as per IS : 1538. Upto 300 mm dia. Above 300 mm dia. Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS:13382. Upto 300 mm dia. Above 300 mm dia. Providing and laying D.I. Specials of Class K-12 suitable for push-on jointing as per IS : 9523. Upto 600 mm dia. Above 600 mm dia. Providing and laying D.I. Specials of Class K-12 suitable for mechanical jointing as per IS : 9523. 600 mm dia. Above 600 mm dia. Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket. 100 mm dia pipes. 150 mm dia pipes. 200 mm dia pipes. 250 mm dia pipes. 300 mm dia pipes. 350 mm dia. pipes. 400 mm dia pipes. 450 mm dia pipes. 500 mm dia pies. 600 mm dia pipes. 650 mm dia pipes. 700 mm dia pipes. 800 mm dia pipes. 900 mm dia pipes. 1000 mm dia pipes. Providing and laying Double Flanged (screwed/welded) centrifugally (spun) cast iron, class B ( IS-1536 ). 100 mm dia C.I. Double Flanged Pipe. 150 mm dia C.I. Double Flanged Pipe. 200 mm dia C.I. Double Flanged Pipe. 250 mm dia C.I. Double Flanged Pipe. 300 mm dia C.I. Double Flanged Pipe. 350 mm dia C.I. Double Flanged Pipe. 400 mm dia C.I. Double Flanged Pipe. 450 mm dia C.I. Double Flanged Pipe. 500 mm dia C.I. Double Flanged Pipe. 600 mm dia C.I. Double Flanged Pipe. Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329. 100 mm dia Ductile Iron Class K - 7 pipes. 150 mm dia Ductile Iron Class K - 7 pipes.

Each

133.30

Quintal Quintal

4202.85 4737.80

Quintal Quintal

6305.85 6586.90

18.068.01 18.068.02 18.069 18.069.01 18.069.02 18.070

Quintal Quintal

10487.25 15685.00

Quintal Quintal

11023.85 16644.40

18.070.01 18.070.02 18.070.03 18.070.04 18.070.05 18.070.06 18.070.07 18.070.08 18.070.09 18.070.10 18.070.11 18.070.12 18.070.13 18.070.14 18.070.15 18.071 18.071.01 18.071.02 18.071.03 18.071.04 18.071.05 18.071.06 18.071.07 18.071.08 18.071.09 18.071.10 18.072 18.072.01 18.072.02

Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint Joint

39.00 60.30 98.20 111.70 153.10 182.15 340.40 378.35 393.20 489.30 739.65 853.45 953.35 1255.25 1523.90

One One One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

1151.15 1781.85 2468.85 3304.85 4201.30 5372.75 6940.35 8985.75 11716.30 15287.90

One Metre One Metre

703.30 1025.40

Page 99

DSR_2007

18.072.03 18.072.04 18.072.05 18.072.06 18.072.07 18.072.08 18.072.09 18.072.10 18.072.11 18.072.12 18.072.13 18.072.14 18.072.15 18.072.16 18.072.17 18.072.18 18.072.19 18.072.20 18.072.21 18.072.22 18.072.23 18.072.24 18.072.25 18.072.26 18.072.27 18.072.28 18.072.29 18.073

18.073.01 18.073.02 18.073.03 18.073.04 18.073.05 18.073.06 18.073.07 18.073.08 18.073.09 18.073.10 18.073.11 18.074 18.074.01 18.074.02 18.075 18.075.01 18.075.02 18.075.03 18.076 18.076.01

200 mm dia Ductile Iron Class K - 7 pipes. One Metre 250 mm dia Ductile Iron Class K - 7 pipes. One Metre 300 mm dia Ductile Iron Class K - 7 pipes. One Metre 350 mm dia Ductile Iron Class K - 7 pipes. One Metre 400 mm dia Ductile Iron Class K - 7 pipes. One Metre 450 mm dia Ductile Iron Class K - 7 pipes. One Metre 500 mm dia Ductile Iron Class K - 7 pipes. One Metre 600 mm dia Ductile Iron Class K - 7 pipes. One Metre 700 mm dia Ductile Iron Class K - 7 pipes. One Metre 800 mm dia Ductile Iron Class K - 7 pipes. One Metre 900 mm dia Ductile Iron Class K - 7 pipes. One Metre 1000 mm dia Ductile Iron Class K - 7 pipes. One Metre 100 mm dia Ductile Iron Class K - 9 pipes. One Metre 150 mm dia Ductile Iron Class K - 9 pipes. One Metre 200 mm dia Ductile Iron Class K - 9 pipes. One Metre 250 mm dia Ductile Iron Class K - 9 pipes. One Metre 300 mm dia Ductile Iron Class K - 9 pipes. One Metre 350 mm dia Ductile Iron Class K - 9 pipes. One Metre 400 mm dia Ductile Iron Class K - 9 pipes. One Metre 450 mm dia Ductile Iron Class K - 9 pipes. One Metre 500 mm dia Ductile Iron Class K - 9 pipes. One Metre 600 mm dia Ductile Iron Class K - 9 pipes. One Metre 700 mm dia Ductile Iron Class K - 9 pipes. One Metre 750 mm dia Ductile Iron Class K - 9 pipes. One Metre 800 mm dia Ductile Iron Class K - 9 pipes. One Metre 900 mm dia Ductile Iron Class K - 9 pipes. One Metre 1000 mm dia Ductile Iron Class K - 9 pipes. One Metre Providing and laying Double Flanged ( Screwed / W elded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329. 100 mm dia Ductile Iron Double Flanged. One Metre 150 mm dia Ductile Iron Double Flanged. One Metre 200 mm dia Ductile Iron Double Flanged. One Metre 250 mm dia Ductile Iron Double Flanged. One Metre 300 mm dia Ductile Iron Double Flanged. One Metre 350 mm dia Ductile Iron Double Flanged. One Metre 400 mm dia Ductile Iron Double Flanged. One Metre 450 mm dia Ductile Iron Double Flanged. One Metre 500 mm dia Ductile Iron Double Flanged. One Metre 600 mm dia Ductile Iron Double Flanged. One Metre 700 mm dia Ductile Iron Double Flanged. One Metre Providing and fixing unplastissised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality. 15 mm nominal bore with 30 cm. length. Each 15 mm nominal bore with 45 cm. length. Each Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved qualityand colour. . 15 mm nominal bore, weighing not less than 32 gms. Each 20 mm nominal bore, weighing not less than 40 gms. Each 25 mm nominal bore, weighing not less than 62 gms. Each Cutting holes upto 30 x 30 cm in walls including making good the same : W ith F.P.S. bricks. Each

1457.15 1972.55 2784.90 3214.25 3837.60 4550.35 5367.20 7081.30 8795.70 12243.20 15055.70 18247.50 775.50 1152.80 1589.45 2056.35 2639.45 3102.25 4435.65 4925.90 6591.35 7404.65 10052.75 11464.10 11808.40 13770.10 15500.90

2206.35 3055.35 3963.40 5262.65 6771.65 8434.20 10076.25 12180.70 14761.20 20023.70 24693.40

45.55 52.90

38.75 45.75 66.65

90.90

Page 100

DSR_2007

18.077

18.078 18.079

18.080

18.080.01 18.080.02 18.080.03 18.080.04 18.080.05 18.080.06 18.080.07 18.080.08 18.080.09 18.080.10 18.080.11 18.080.12 18.081

18.081.01 18.081.02 18.081.03 18.081.04 18.081.05 18.081.06 18.081.07 18.081.08 18.081.09 18.081.10 18.081.11 18.081.12 18.082

18.082.01 18.082.02 18.082.03 18.082.04 18.082.05 18.082.06 18.082.07 18.082.08

Cutting holes upto 15 x 15 cm in RCC floors and roofs for passing drain pipe etc., and repairing the hole after insertion of drain pipe etc. with cement concrete1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) including finishing complete so as to make it leak proof. Making chases upto 7.5 x 7.5 cm in walls including making good and finishing with matching surface after housing GI pipe etc. Making hole upto 20 x 20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including disposal of malba. Disinfecting CI water mains by flushing with water containing bleaching powder at 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory. 80 mm diamter CI Pipe. 100 mm diamter CI Pipe. 125 mm diamter CI Pipe. 150 mm diamter CI Pipe. 200 mm diamter CI Pipe. 250 mm diamter CI Pipe. 300 mm diamter CI Pipe. 350 mm diamter CI Pipe. 400 mm diamter CI Pipe. 450 mm diamter CI Pipe. 500 mm diamter CI Pipe. 600 mm diamter CI Pipe. Extra for every operation disinfecting the CI main by flushing with water containing bleaching powder at 0.5 gms per litre of water and cleaning the same with fresh water, including getting the samples of water tested in the Municipal laboratory. 80 mm diamter CI Pipe. 100 mm diamter CI Pipe. 125 mm diamter CI Pipe. 150 mm diamter CI Pipe. 200 mm diamter CI Pipe. 250 mm diamter CI Pipe. 300 mm diamter CI Pipe. 350 mm diamter CI Pipe. 400 mm diamter CI Pipe. 450 mm diamter CI Pipe. 500 mm diamter CI Pipe. 600 mm diamter CI Pipe. Dismantling old CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre. 80 mm diameter CI pipe. 100 mm diameter CI pipe. 125 mm diameter CI pipe. 150 mm diameter CI pipe. 200 mm diameter CI pipe. 250 mm diameter CI pipe. 300 mm diameter CI pipe. 350 mm diameter CI pipe.

Each One Metre.

82.25 36.65

One metre

70.05

One One One One One One One One One One One One

hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred

metre metre metre metre metre metre metre metre metre metre metre metre

289.75 381.15 478.85 580.80 786.95 1007.55 1150.00 1302.95 1470.50 1645.65 1834.55 2236.70

One One One One One One One One One One One One

hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred hundred

metre metre metre metre metre metre metre metre metre metre metre metre

106.85 130.05 159.55 188.25 283.70 335.95 388.50 463.95 542.10 624.90 709.35 887.95

One One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre Metre

82.65 85.35 87.80 90.45 99.95 109.30 117.30 124.60

Page 101

DSR_2007

18.082.09 18.082.10 18.082.11 18.082.12 18.083 18.083.01 18.083.02 18.083.03 18.083.04 18.083.05 18.083.06 18.083.07 18.083.08 18.083.09 18.083.10 18.083.11 18.083.12 19.001

400 mm diameter CI pipe. 450 mm diameter CI pipe. 500 mm diameter CI pipe. 600 mm diameter CI pipe. Labour for cutting CI pipe with steel saw. 80 mm diameter CI pipe. 100 mm diameter CI pipe. 125 mm diameter CI pipe. 200 mm diameter CI pipe. 250 mm diameter CI pipe. 300 mm diameter CI pipe. 350 10.083.01 mm diameter CI pipe. 400 mm diameter CI pipe. 450 mm diameter CI pipe. 500 mm diameter CI pipe. 600 mm diameter CI pipe. Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 100 mm diameter 150 mm diameter 200 mm diameter 230 mm diameter 250 mm diameter 300mm diameter.

One One One One

Metre Metre Metre Metre cut cut cut cut cut cut cut cut cut cut cut cut

131.15 137.95 143.65 153.20 22.10 29.80 41.75 56.15 74.90 92.65 111.40 129.10 147.70 165.60 184.20 218.55

Each Each Each Each Each Each Each Each Each Each Each Each

19.001.01 19.001.02 19.001.03 19.001.04 19.001.05 19.001.06 19.002

One One One One One One

Metre Metre Metre Metre Metre Metre

105.90 151.65 247.15 269.90 342.85 469.65

Providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size )alround S.W . pipes including bed concrete as per standard design: 100 mm diameter S.W . pipe 19.002.01 150 mm diameter S.W . pipe 19.002.02 200 mm diameter S.W . pipe 19.002.03 230 mm diameter S.W . pipe 19.002.04 250 mm diameter S.W . pipe 19.002.05 Providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse 19.003 sand : 10 graded stone aggregate 40 mm nominal size ) upto haunches of S.W . pipes including bed concrete as per standard design : 100 mm diameter S.W . pipe 19.003.01 150 mm diameter S.W . pipe 19.003.02 200 mm diameter S.W . pipe 19.003.03 230 mm diameter S.W . pipe 19.003.04 250 mm diameter S.W . pipe 19.003.05 300mm diameter S.W . Pipe. 19.003.06 Providing and fixing square-mouth S.W . gully trap grade 'A' complete 19.004 with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100 x 100 mm size P type 19.004.01 19.004.01.01 with F.P.S. bricks class designation 75 19.004.01.02 W ith Sewer bricks conforming to IS : 4885. 150 x 100 mm size 'P' type 19.004.02 19.004.02.01 W ith F.P.S. bricks class designation 75.

One One One One One

Metre Metre Metre Metre Metre

331.20 405.50 472.15 516.90 546.00

One One One One One One

Metre Metre Metre Metre Metre Metre

157.40 255.10 299.85 328.95 349.10 402.80

Each Each Each

935.15 1033.35 961.95

Page 102

DSR_2007

19.004.02.02 19.004.03 19.004.03.01 19.004.03.02 19.005

W ith Sewer bricks conforming to IS : 4885. 180 x 150 mm size P type W ith F.P.S. bricks class designation 75. W ith Sewer bricks conforming to IS : 4885. Dismantling of old S.W . pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 100 mm diameter 150 mm diameter 200 mm diameter 230 mm diameter 250 mm diameter 300 mm diameter 350 mm dia meter 400 mm diameter 450 mm dia meter

Each Each Each

1060.15 1036.75 1134.95

19.005.01 19.005.02 19.005.03 19.005.04 19.005.05 19.005.06 19.005.07 19.005.08 19.005.09 19.006

One One One One One One

Metre Metre Metre Metre Metre Metre

13.35 14.75 15.70 16.20 16.65 17.60 20.25 22.15 23.10

One Metre One Metre One Metre

Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete: 100 mm dia. R.C.C. pipe 19.006.01 150 mm dia. R.C.C. pipe 19.006.02 250 mm dia. R.C.C. pipe 19.006.03 300 mm dia. R.C.C. pipe 19.006.04 450 mm dia. R.C.C. pipe 19.006.05 500 mm dia. R.C.C. pipe 19.006.06 600 mm dia. R.C.C. pipe 19.006.07 700 mm dia. R.C.C. pipe 19.006.08 800 mm dia. R.C.C. pipe 19.006.09 900 mm dia. R.C.C. pipe 19.006.10 1000 mm dia. R.C.C. pipe 19.006.11 1100 mm dia. R.C.C. pipe 19.006.12 1200 mm dia. R.C.C. pipe 19.006.13 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement 19.007 : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including C.I. cover with 19.007.01 frame (light duty) 455 x 610 mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) 19.007.01.01 W ith F.P.S. bricks with class designation 75. 19.007.01.02 W ith Sewer bricks conforming to IS:4885. Inside size 120 x 90 cm and 90 cm deep including C.I. cover with 19.007.02 frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg. (weight of cover 58 kg and weight of frame 58 kg.)

One One One One One One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre Metre

173.95 202.85 258.20 338.75 499.55 584.85 895.10 1000.90 1167.40 1413.90 1740.95 2093.70 2208.30

Each Each

5383.70 5640.50

Page 103

DSR_2007

19.007.02.01 W ith F.P.S. bricks with class designation 75. 19.007.02.02 W ith Sewer bricks conforming to IS:4885. Inside size 120 x 90 cm and 90 cm deep including C.I. cover with 19.007.03 frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 10058 kg ) 19.007.03.01 W ith F.P.S. bricks with clas designation 75. 19.007.03.02 W ith Sewer bricks conforming to IS:4885. Extra for depth for manholes 19.008 Size 90 x 80 cm 19.008.01 19.008.01.01 W ith F.P.S. bricks class designation 75. 19.008.01.02 W ith Sewer bricks conforming to IS:4885. Size 120 x 90 cm 19.008.02 19.008.02.01 W ith F.P.S. bricks class designation 75. 19.008.02.02 W ith Sewer bricks conforming to IS:4885. 19.009 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at in cement mortar 1:4 ( 1 cement : 4 coarse sand ), inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement all complete as per standard design : 19.009.01 0.91 m deep with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation ) 560 mm internal diameter conforming to IS :12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid separately). 19.009.01.01 W ith F.P.S. bricks class designation 75. 19.009.01.02 W ith Sewer bricks conforming to IS:4885. Extra depth for circuler type manhole 0.91 m internal dia (at bottom) 19.010 with beyond 0.91m to 1.67m. W ith F.P.S. bricks class designation 75. 19.010.01 W ith Sewer bricks conforming IS : 4885. 19.010.02 19.011 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement all complete as per standard design:

Each Each

11882.20 12584.65

Each Each

15673.85 16278.10

One Metre One Metre One Metre One Metre

2654.00 3401.80 3179.95 4071.30

Each Each

4933.50 5347.90

One Metre One Metre

2289.75 2915.90

Page 104

DSR_2007

19.011.01 1.68 m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S.12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). 19.011.01.01 W ith F.P.S. bricks class designation 75. 19.011.01.02 W ith Sewer bricks conforming IS : 4885. Extra depth for circuler type manhole 1.22 m internal dia (at bottom) 19.012 beyond 1.68 m to 2.29 m. W ith F.P.S. bricks class designation 75. 19.012.01 W ith Sewer bricks conforming IS : 4885. 19.012.02 19.013 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement : 4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement all complete as per standard design : 19.013.01 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation ) 560 mm internal diameter conforming to I.S.12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately ). 19.013.01.01 W ith F.P.S. bricks class designation 75. 19.013.01.02 W ith Sewer bricks conforming IS : 4885. Extra depth for circuler type manhole 1.52 m internal dia (at bottom ) 19.014 beyond 2.30 m. W ith F.P.S. bricks class designation 75. 19.014.01 W ith Sewer bricks conforming IS : 4885. 19.014.02 Providing M.S. foot rests including fixing in manholes with 20 x 20 x 19.015 10 cm cement concrete blocks 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) as per standard design : W ith 20 x 20 mm square bar 19.015.01 W ith 20 mm diameter round bar 19.015.02 Each Each 8946.25 9934.70

One Metre One Metre

2954.75 3772.05

Each Each

18281.60 21089.40

One Metre One Metre

6956.05 9069.45

Each Each

149.85 125.15

Page 105

DSR_2007

19.016 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20 x 20 x 10 cm cement concrete blocks 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size): W ith 20 x 20 mm square bar W ith 20 mm diameter round bar Supplying and fixing C.I. cover without frame for manholes : 455 x 610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. 560 mm diameter C.I. cover ( heavy duty ) the weight of the cover to be not less than 108 kg. Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality : L D - 2.5 Rectangular shape 600 x 450 mm internal dimensions Square shape 450 mm internal dimensions Circular shape 450 mm internal diameter M D - 10 Square shape 450 mm internal dimension Circular shape 500 mm internal diameter H D - 20 Circular shape 560 mm internal diameter EHD - 35

Each

182.40

19.017

19.017.01 19.017.02 19.018 19.018.01 19.018.02 19.018.03 19.019 19.019.01 19.019.01.01 19.019.01.02 19.019.01.03 19.019.02 19.019.02.01 19.019.02.02 19.019.03 19.019.03.01 19.019.04

Each Each

167.95 143.20

Each Each Each

1007.45 2507.35 4293.30

Each Each Each Each Each Each

883.25 748.50 671.80 825.35 792.75 1110.30

19.019.04.01 Circular shape 560 mm internal dia. Supplying and fixing C.I. cover 300 x 300 mm without frame for gully 19.020 trap ( standard pattern ) the weight of cover to be not less than 4.5 kg. Making connection of drain or sewer line with existing manhole 19.021 including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 230 mm diameter 19.021.01 For pipes 250 to 300 mm diameter 19.021.02 For pipes 350 to 450 mm diameter 19.021.03

Each

1223.00

Each

205.30

Each Each Each

164.30 205.40 302.95

Page 106

DSR_2007

19.022 Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased alround with cement concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) with all centring and shuttering required, cutting holes in walls and making good with brick work in cement mortar 1:4 ( 1 cement : 4 fine sand ) plastered with cement mortar 1:3 ( 1 cement : 3 coarse sand ) on inside of the manhole wall lead caulked joints between sand cast iron pipes and fittings, stiff cement mortar 1:1 ( 1 cement : 1 fine sand ) joints between sand cast iron tee and S.W . pipe, making required channels complete as per standard design and specifications : 100 mm dia. sand cast iron drop connection 150 mm dia. sand cast iron drop connection Extra for depths beyond 60 cm of sand cast iron drop connection complete : For 100 mm dia. sand cast iron drop connection For 150 mm dia. sand cast iron drop connection. Dismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead : Rectangular manhole 90 x 80 cm and 45 cm deep Rectangular manhole 120 x 90 cm and 90 cm deep Rectangular arch type manhole 140 x 90 cm and 2.45 m deep Circular manhole 122 cm diameter and 1.68 m deep Extra for depth of manholes dismantled : Rectangular manhole 90x80 cm and 45 cm deep Rectangular manhole 120 x 90 cm and 90 cm deep Rectangular arch type manhole 140 x 90 cm and 2.45 m deep (upto 4.25 m depth) Circular manhole 122 cm diameter and 1.68 m deep ( upto 2.29 m depth Rectangular manhole 90 x 80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 Rectangular manhole 120 x 90 cm with circular cover 500 mm dia of grade MD - 10 Rectangular manhole 120 x 90 cm with circular cover 560 mm dia of grade HD - 20 Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 Constructing brick masonry road gully chamber 50 x 45 x 60 cm with bricks of class designation 75 in cement mortar 1:4 ( 1 cement : 4 fine sand ) including 500 x 450 mm precast R.C.C. horizontal grating with frame complete as per standard design : W ith F.P.S. bricks Constructing brick masonry road gully chamber 45 x 45 x 77.5 cm with bricks of class designation 75 in cement mortar 1:4 ( 1 cement : 4 fine sand ) with precast R.C.C. vertical grating complete as per standard design : W ith F.P.S. bricks

19.022.01 19.022.02 19.023 19.023.01 19.023.02 19.024

Each Each

2978.05 4530.90

One Metre One Metre

1004.65 1504.90

19.024.01 19.024.02 19.024.03 19.024.04 19.025 19.025.01 19.025.02 19.025.03 19.025.04 19.026.01 19.026.02 19.026.03 19.026.04 19.027

Each Each Each Each One Metre One Metre One Metre One Metre Each Each Each Each

388.75 680.85 1288.10 988.45 309.75 368.80 298.15 522.65 824.25 1287.45 1198.10 115.25

19.027.01 19.028

Each

2248.35

19.028.01

Each

2358.00

Page 107

DSR_2007

19.029 Constructing brick masonry road gully chamber 110 x 50 x 77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand ) including 500 x 450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : W ith F.P.S. bricks Each Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:5 ( 1 cement : 5 fine sand ) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.030.01 Inside dimensions 455 x 610 mm and 45 cm deep for single pipe line. 19.030.01.01 W ith F.P.S. bricks Inside dimensions 500 x 700 mm and 45 cm deep for pipe line with 19.030.02 one or two inlets 19.030.02.01 W ith F.P.S. bricks Inside dimensions 600 x 850 mm and 45 cm deep for pipe line with 19.030.03 three or more inlets 19.030.03.01 W ith F.P.S. bricks Extra for depth beyond 45 cm of brick masonry chamber 19.031 For 455 x 610 mm size 19.031.01 19.031.01.01 W ith F.P.S. bricks For 500 x 700 mm size 19.031.02 19.031.02.01 W ith F.P.S. bricks For 600 x 850 mm size 19.031.03 19.031.03.01 W ith F.P.S. bricks Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry 19.032 brick honey comb shaft with bricks of class designation 75 and S.W . drain pipe 100 mm diameter, 1.8 m long complete as per standard design. W ith F.P.S. bricks 19.032.01 Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats 19.033 including S.W . drain pipe 100 mm diameter and 1.20 m long complete as per standard design. Providing and fixing S.W . intercepting trap in manholes with stiff 19.034 mixture of cement mortar 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete: 100 mm dia 19.034.01 150 mm dia 19.034.02 19.26 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) Each 3146.40

19.029.01 19.030

4272.30

Each

3590.95

Each

4068.50

One Metre One Metre One Metre

1845.65 2013.70 2345.30

Each

9938.65

Each

1074.90

Each Each

198.35 281.55

Page 108

DSR_2007

20.001 Providing, driving and installing driven cast-in-situ reinforced cement concrete piles of specified diameter and length below the pile cap M 35 in cement concrete, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embeded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap). 400 mm dia piles 450 mm dia piles 500 mm dia piles 550 mm dia piles 750mm dia piles 1000 mm dia piles 1200 mm dia piles 1500 mm dia piles Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified diametre and length below the pile cap M 35 in cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with casing and / or bentonite solution and the length of the pile to be embeded in the pile cap (Length of pile for payment shall be measured upto bottom of pile cap). 300 mm dia. pile 400 mm dia. piles 450 mm dia. piles 500 mm dia. Piles. 600 mm dia. piles 750 mm dia piles 1000 mm dia piles 1200 mm dia piles 1500 mm dia piles Boring, Providing and installing cast in situ single under reamed piles of specified diametre and length below pile cap in M 35 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap. (Length of pile for payment shall be measured upto to the bottom of pile cap). 300 mm dia. piles 400 mm dia. piles 450 mm dia. piles 550 mm dia. piles Extra over item No. 20.3 for providing additional bulb in under reamed piles, under specified dia meter . (Only the quantity of extra bulbs are to be paid). 300 mm dia piles. 400 mm dia piles. 450 mm dia piles. 550 mm dia piles.

20.001.01 20.001.02 20.001.03 20.001.04 20.001.05 20.001.06 20.001.07 20.001.08 20.002

One One One One One One One One

Metre Metre Metre Metre Metre Metre Metre Metre

1428.85 1758.75 2120.00 2285.95 3826.05 6242.15 7981.90 11114.75

20.002.01 20.002.02 20.002.03 20.002.04 20.002.05 20.002.06 20.002.07 20.002.08 20.002.09 20.003

One Metre One Metre One Metre metre One Metre One Metre One Metre One Metre One Metre

1070.50 1302.00 1705.95 2005.70 2559.60 3786.75 6220.05 7993.15 11276.10

20.003.01 20.003.02 20.003.03 20.003.04 20.004

One One One One

Metre Metre Metre Metre

1623.00 1933.55 2118.25 2332.70

20.004.01 20.004.02 20.004.03 20.004.04

Each Each Each Each

1030.25 1167.00 1249.70 1391.60

Page 109

DSR_2007

20.005 Providing, driving and installing driven pre-cast reinforced cement concrete piles of specified diameter and length below the pile cap in M 35 cement concrete to carry safe working load not less than specified. W ith a central through performed hole with M.S. black pipe of dia, 40 mm for grouting with cement sand grouting of mix 1:2 ( 1 cement : 2 coarse sand) under sufficient positive pressure to ensure complete filling including centring, shuttering, driving and removing the steel casing pipe and lifting casing etc. complete but excluding the cost of steel reinforcement. (Length of pile for payment shall be measured from top of the shoe to the bottom of pile cap). 400 mm dia. 450 mm dia. 500 mm dia. 550 mm dia. 750 mm dia piles 1000 mm dia piles Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification and the direction of the Engineer-inCharge. Single pile upto 50 tonne capacity.. Initial test. Routine test Single pile above 50 tonne and upto 100 tonne capacity. Initial test. Routine test. Group of two or more piles upto 50 tonne capacity. Initial test. Routine test.

20.005.01 20.005.02 20.005.03 20.005.04 20.005.05 20.005.06 20.006

One One One One One One

Metre Metre Metre Metre Metre Metre

1691.55 1956.70 2104.70 2345.55 4135.35 5691.35

20.006.01 20.006.01.01 20.006.01.02 20.006.02 20.006.02.01 20.006.02.02 20.006.03 20.006.03.01 20.006.03.02 20.007

per test per test per test per test per test per test

22649.20 13357.20 31941.20 20907.00 43.556.20 26714.50

Cyclic vertical load testing of pile in accordance with IS code of practice IS : 2911 (Part IV) including preparation of pile head etc for :Single pile 20.007.01 20.007.01.01 Upto 50 tonne capacity pile. 20.007.01.02 Above 50 tonne and upto 100 tonne capacity pile. Group of two piles. 20.007.02 20.007.02.01 Upto 50 tonne capacity each. Lateral load testing of single pile in accordance with I.S. Code of 20.008 practice I.S:2911 (Part IV) for determining safe allowable lateral load on pile: Upto 50 tonne capacity each. 20.008.01 Above 50 tonne and upto 100 tonne capacity pile. 20.008.02

per test per test per test

13357.20 20907.00 26714.50

per test per test

13357.20 20907.00

Page 110

DSR_2007

21.001 Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / Neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately.) For fixed portion

21.001.01 21.001.01.01

Anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15 ) One Kilogram 21.001.01.02 Powder coated aluminium ( minimum thickness of powder coating 50 micron ). One Kilogram 21.001.01.03 Polyster powder coated aluminium ( minimum thickness of polyster powder coating 50 micron ) One Kilogram 21.001.02 For shutters of doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (Fittings shall be paid for separately.) 21.001.02.01 Anodised aluminium ( anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 ). One Kilogram 21.001.02.02 Powder coated aluminium ( minimum thickness of powder coating 50 micron ). One Kilogram 21.001.02.03 Polyster powder coated aluminium ( minimum thickness of polyster powder coating 50 micron ). One Kilogram Providing and fixing 12 mm thick prelaminated particle board flat 21.002 pressed three layer or graded wood particle board conforming to IS:12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side 21.002.01 and balancing lamination on other side. One Square Metre 21.002.02 Prelaminated particle board with decorative lamination on both sides. One Square Metre Providing and fixing glazing in aluminium door, window, ventilator 21.003 shutters and partitions etc. with PVC / Neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) W ith float glass panes of 4.0 mm thickness. One Square Metre 21.003.01 W ith float glass panes of 5.50 mm thickness . One Square Metre 21.003.02 W ith float glass panes of 8 mm thickness. One Square Metre 21.003.03

290.45 306.30 312.40

310.45 326.60 332.85

776.05 812.60

554.95 673.55 556.00

Page 111

DSR_2007

21.004 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS:6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. W ith Stainless Steel cover plate. W ith Brass cover plate. Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron ) consisting of tee / angle sections, of approved make conforming to IS:733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed to wall with rawl plugs @ 450 mm centre to centre and fixing the frame work to GI level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge ( level adjusting hangers, ceiling cleats and expansion hold fastners to be paid for separately ). Providing and fixing 6 mm dia. GI level adjusting hangers ( upto 1200 mm length ) fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fastners 12.5 mm dia. 40mm long complete as per direction of Engineer-in-Charge. Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces / ceilings with full threaded, cadmium plated steel screws 4 mm dia. stem, 30 mm long and aluminium washers 2 mm thick, 15 mm dia. at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Anodised aluminium sheet 2.5 mm thick ( anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 ). Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron ). Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width. Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion. For shutters of doors, windows & ventilators. Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc., with 6 mm thick clear float glass both side having 12mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant ( Both primary and secondary sealant ) etc., as per specifications, drawings and direction of Engineer-in-charge complete.

21.004.01 21.004.02 21.005

Each Each

1733.50 1907.70

One Kg

364.45

21.006

Each

71.10

21.007

21.007.01

One Kg One Kg

335.85 351.70

21.007.02 21.008

21.008.01 21.009 21.009.01 21.009.02 21.010

One Metre.

58.85

One Kilogram One Kilogram

9.30 9.30

One Square Metre.

2808.90

Page 112

DSR_2007

21.011

21.011.01 21.011.02 21.011.03 21.011.04 21.011.05 21.012

21.012.01 21.012.02 21.012.03 21.013

21.014

21.015

21.015.01 21.015.02 21.015.03 21.016 21.016.01 21.016.02 21.016.03

Providing and fixing stainless steel ( SS 304 grade ) adjustable friction windows stays of approved quality with necessary stainless steel screws etc., to the side hung windows as per direction of Engineer-in-charge complete. 205 x 19 mm 255 x 19 mm 366 x 19 mm 510 x 19 mm 710 x 19 mm Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc., complete as per direction of Engineer-in-Charge. Anodized ( AC - 15 ) aluminium tubular handle bar. Powder coated minimum thickness 50 micron aluminium tubular handle bar. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar. Providing and fixing 100 mm brass locks ( Best make of approved quality ) for aluminium doors including necessary cutting and making good etc., complete. Provoding and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868. Minimum anodic coating of grade AC 15 ) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS : 733 and IS : 1285 fixed with rawl plugs and stainless steel screws etc. Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc., complete. Anodized ( AC 15 ) aluminium. Powder coated minimum thickness 50 micron aluminium. Polyester powder coated minimum thickness 50micron aluminium. Providing and fixing round shape handle of outer dia 100mm with SS screws etc., complete as per direction of Engineer-in-charge. Anodized ( AC 15 ) aluminium Powder coated minimum thickness 50 micron aluminium. Polyster powder coated minimum thickness 50 micron aluminium.

each each each each each

175.10 193.20 247.55 458.95 836.45

each each each

433.75 458.45 467.95

Each Number

150.00

One Kg.

303.90

each each each

37.20 40.70 43.00

each each each

45.30 49.95 52.30

Page 113

DSR_2007

22.001 Providing and laying integral cement based treatment for water proofing on horizontal surface at all ldepth below ground level for under ground structures as directed by by Engineer-in-Charge and consisting of : I) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand ) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound . II) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. III) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8.00 cudm/sqm thoroughly embedded in the 2nd layer : Using rough kota stone. One Square Metre Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportion with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge. Using rough Kota stone. One Square Metre Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W .C., kitchen and the like consisting of : (i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS:2645 in recommended proportions including rounding off junction of vertical and horizontal surface.. (ii) IInd course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surfae.. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)

22.001.01 22.002

540.30

22.002.01 22.003

647.85

One Square Metre

272.50

Page 114

DSR_2007

22.004

22.004.01 22.004.02 22.004.03 22.005

Providing and placing in position suitable PVC water stops conforming to IS:12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete. Serrated with central bulb ( 225 mm wide, 8-11 mm thick ) Dumb bell with central bulb ( 180 mm wide, 8 mm thick ) Kickers ( 320 mm wide, 5 mm thick ) Providing and laying water proofing treatment in sunken portion of W Cs, bathroom etc. by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm. mixed with water proofing compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm. mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. The rate includes preparation of surcace, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. Note: Redering/plastering as protective layer, if required will be paid separately. Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with W ater Proofing compound consisting of applying: a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm. mixed with water proofing cement compound @ 0.253 kg./sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 thickness consisting of slurry of cement @ 1.289 kg./sqm. mixed with @ 0.670 kg/sqm. and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatement will be taken upto 30 cm. on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treatment surface will be mesured.

One Metre One Metre One Metre

386.75 358.85 380.95

One Square Metre

143.85

22.006

One Square Metre

237.50

Page 115

DSR_2007 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations. a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer-incharge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing conforming to IS:2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer-incharge.. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 course sand ) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-incharge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3mm deep.. e) The whole terrace so finished shall be flooded with water for a W ith average thickness of 120 mm and minimum thickness at khurra as 65 mm. One Square Metre Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS: 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic diameter per square metre including preparation of surface but exluding grading complete with : 22.008.01 Bitumen felt ( hessian base ) type 3 grade I conforming to IS : 1322. One Square Metre 22.009 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourt courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 . and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. One Square Metre 184.80

22.007

22.007.01 22.008

541.50

292.75

Page 116

DSR_2007

22.010

Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot at 1.45, 1.20 and 1.70 Kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cudm per sqm including preparation of surface, excluding grading, complete. One Square Metre Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot at 1.45, 1.20 and 1.70 Kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. Supplying and applying bitumenous solution primer on roof and or wall surface at 0.24 litre per sqm. Deduct for omitting in water proofing treatment final course of spreading stone grit 6 mm down size or pea sized gravel : At 6 cubic dm per sqm At 8 cubic dm per sqm. Grading roof for water proofing treatment with: Cement concrete 1:2:4 ( 1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) Cement mortar 1:3 ( 1cement : 3 coarse sand ). Cement mortar 1:4 ( 1 cement : 4 coarse sand ) Providing and laying in situ seven course water proofing treatment with APP (Atactic PolyPropylene) modified Polymetric memberane over roof consisting of first coat of bitumen primer @ 0.40 Kg. per sqm. 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm. which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymetric membrane 1.5mm thic of 2.25 Kg/sqm. weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micrown HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement :3 fine sand) mixed with 2% integral water proofint compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat which shall be paid for separately as per DSR Item No.12.19

315.35

22.011

One Square Metre One Square Metre

315.45 15.00

22.012 22.013 22.013.01 22.013.02 22.014 22.014.01 22.014.02 22.014.03 22.015

One Square Metre One Square Metre

8.65 11.05

One Cubic Metre One Cubic Metre One Cubic Metre

3314.95 5045.35 4357.65

One Square Metre

283.25

Page 117

DSR_2007

22.016

Providing and laying in situ five course water proofing treatment with APP (Atactic PolyPropylene) modified Polymetric memberane over roof consisting of first coat of bitumen primer @ 0.40 Kg. per sqm. 2nd & 4th courses of bonding material @ 1.20 Kg/sqm. which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymetric membrane 2.0mm thic of 3.00 Kg/sqm. weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micrown HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement :3 fine sand) mixed with 2% integral water proofint compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat which shall be paid for separately as per DSR Item No.12.19. One Square Metre Providing and laying in situ seven course water proofing treatment with APP (Atactic PolyPropylene) modified Polymetric memberane over roof consisting of first coat of bitumen primer @ 0.40 Kg. per sqm. 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm. which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymetric membrane 2.0mm thick of 3.00 Kg/sqm. weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micrown HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement :3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat which shall be paid for separately as per DSR Item No.12.19. One Square Metre

221.15

22.017

372.70

22.018 Providing and fixing APP (Atactic PolyPropylene) modified prefabricated five layer 2mm thick waer proofing memberane black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrace @ 0.40 ltr/sq.mt. by the same membrance manufacture of density at 25 degree C, 0.87 - 0.89 kg/ltr. and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be : Joint strength in longitudinal and transverse direction at 23 degree C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150 degree C. Cold flexibility shall be upto -2 degree C when tested in accodance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. 2mm ( for corrugated roof shets ). One Square Metre

22.018.01

256.25

Page 118

DSR_2007

22.019 Providing and laying APP (Atactic PolyPropylene) modified prefabricated five layer 3mm thick water proofing memberane black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sq.mt. by the same membrance manufacture of density at 25 degree C, 0.87 - 0.89 kg/ltr. and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be : Joint strength in longitudinal and transverse direction at 23 degree C ,as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150 degree C. Cold flexibility shall be upto -2 degree C when tested in accodance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. 3mm thick. One Square Metre Providing and fixing APP (Atactic PolyPropylene) modified prefabricated five layer 3mm thick water proofing memberane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrace @ 0.40 ltr/sqm. by the same membrance manufacture of density at 25 degree C, 0.870.89 kg/ltr. and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be : Joint strength in longitudinal and transverse direction at 23 degree C as 650/450 /5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150C. Cold flexibility shall be upto -2 degree C when tested in accodance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. 3mm thick. One Square Metre 250 mm diametre C.I. pipe 100 metre Extra for covering top of membrane with Geotextile, 120 gsm. non woven, 100% polyster of thickness 1 to 1.25mm bonded to the membrane with intermittant touch by heating the memberane by Butane Torch as per manufacturers recommendation (for item No.22.18 to 22.20 ) . One Square Metre Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). One Cubic Metre Supplying and stacking of good earth at site including royality and carriage upto 1 km (earth measured in stacks will be reduced by 20% for payment). One Cubic Metre

22.019.01 22.020

304.80

22.020.01 22.020.06 22.021

350.80 697.55

38.75

23.001

16.95

23.002

144.05

Page 119

DSR_2007

23.003

23.004

23.004.01 23.004.02 23.004.03 23.005 23.006 23.007 23.008

23.009 23.010

23.010.01 23.010.02 23.010.03 23.011

23.012

Supplying and stacking sludge at site including royalty and carriage upto 1 km (sludge measured in stacks will be reduced by 8% for payment). Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment): Screened through sieve of I.S. designation 20 mm Screened through sieve of I.S. designation 16 mm Screened through sieve of I.S. designation 4.75 mm. Rough dressing the trenched ground including breaking clods. Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. Fine dressing the ground Spreading of sludge, dump manure or / and good earth in required thickness (Cost of sludge, dump manure or / and good earth to be paid separately).: Mixing earth and sludge or manure in proporition specified or directed. Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). In rows 15 cm apart in either direction. In rows 7.5 cm apart in either direction. In rows 5 cm apart in either direction. Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately). Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

One Cubic Metre

136.85

One Cubic Metre One Cubic Metre One Cubic Metre 100 sqm 100 sqm 100 sqm

82.90 90.75 97.05 33.05 33.05 80.20

One Cubic Metre One Cubic Metre

11.60 7.85

100 sqm 100 sqm 100 sqm

121.00 251.25 384.85

100 sqm

741.50

100 sqm

1318.20

23.013 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). One Cubic Metre

47.90

Page 120

DSR_2007

23.014

23.014.01 23.014.02 23.015

Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume ( 2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 1.2 m dia and 1.2 m deep. Each Holes 60 cm dia, and 60 cm deep. Each Half brick circular tree guard in 50 class designation bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground bottom two courses laid dry and top three courses in cement mortar 1:6 ( 1 cement : 6 fine sand ) and the intermediate courses being in dry honey comb masonry as per design complete : W ith F.P.S. bricks.

146.65 19.25

23.015.01 23.016

Each

595.70

Providing and fixing M.S. flat iron tree guard 60 cm dia. and 2 m height above ground level formed of 4 nos. 25 x 6 mm and 8 nos. 25 x 3 mm vertical M.S. flats rivetted to 3 nos. 25 x 6 mm M.S. flat iron rings in two halves, bolted together with 8 mm dia. and 30 mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of priming, complete in all respects Making tree guard 53 cm dia. and 1.3 m high as per design from 23.017 empty coal tar drums supplied free by the department including providing and fixing 2 nos. M.S. sheet rings 50 x 0.5 mm with rivets complete in all respects including painting inside and outside of tree guard with : A coat of coal tar 23.017.01 Two or more coats of ready mixed paint of approved quality shade 23.017.02 over a priming coat. Making tree guard 53 cm dia. and 2 m high as per design from empty 23.018 coal tar drums supplied free by the department including providing and fixing four legs 40 cm long of 30 x 3 mm M.S. flat riveted to tree guard and providing and fixing 2 nos. M.S. sheet rings 50 x 0.5 mm with rivets complete in all respects including painting inside and outside of tree guard with : A coat of coal tar. 23.018.01 Two or more coats of synthetic enamel paint of approved quality and 23.018.02 shade over a priming coat. Edging with bricks laid dry length wise including excavation, refilling, 23.019 consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m : 75 class designation. 23.019.01 23.019.01.01 F.P.S. Bricks. 50 class designation. 23.019.02 23.019.02.01 F.P.S. Bricks. Filling mixture of earth and sludge or manure in the desired 23.020 proportion in trenches, flooding with water and levelling ( cost of supplying earth and sludge or manure and mixing excluded). Excavation in dumped stones or malba including stacking of 23.021 serviceable and unserviceable material separately and disposal of unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed.

Each

1595.85

Each Each

115.65 187.70

Each Each

238.10 342.15

One Metre One Metre

15.05 13.85

One Cubic Metre

3.95

One Cubic Metre

109.95

Page 121

DSR_2007

23.022

23.023

23.024

Excavation in bajri path including stacking of serviceable and unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed. Excavation in water bound macadam road including stacking the serviceable and unserviceable material separately and disposal of unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed. Flooding the ground with water including making kiaries and dismantling the same.

One Cubic Metre

122.55

One Cubic Metre 100 Square Metre.

150.80 68.40