Anda di halaman 1dari 1

Food Safety Online Ordering

Foodborne Bacteria www.neogen.com/foodsafetyorder.htm

NEO-GRID™ / ISO-GRID™
For Enumeration of Staphylococcus aureus in Foods

Durable Results
ISO-GRID
Disposable
System
NEO-GRID
System

Intended Use Baird-Parker Egg Yolk Agar


Using Baird-Parker Egg Yolk Agar, the ISO-GRID and NEO-GRID Baird-Parker Agar
Membrane Filter Systems are used to provide a method for enumerating Tryptone 10 g/L
Staphylococcus aureus in foods. Beef Extract 5 g/L
Yeast Extract 1 g/L
The Test Sodium Pyruvate 10 g/L
The ISO-GRID/NEO-GRID systems are based on the principle of Glycine 12 g/L
hydrophobic grid membrane filtration (HGMF). Staphylococcus aureus is Lithium Chloride-6-Hydrate 5 g/L
detected through the use of a unique membrane filter containing a grid Agar 17 g/L
of 1,600 squares. First, a diluted sample is prefiltered to eliminate any Final pH: 7.0 ± 0.2 @ 25°C
food particles present. The sample is then filtered through a hydropho-
bic grid membrane filter, and the membrane is placed on Baird-Parker Egg Yolk Tellurite Emulsion (100 mL)
Egg Yolk Agar. Baird-Parker Egg Yolk Agar is specifically formulated Chicken egg yolk 100% solution
to detect Staphylococcus aureus. Potassium Tellurite 0.21 g
After incubation the membrane filter is examined for the presence of
black or dark grey colonies. Any black or dark gray colonies are a pre-
sumptive positive for Staphylococcus aureus, and should be confirmed Ordering Information
using procedures detailed in the Methods Manual.
Prod.# Product description
For Use With Either the NEO-GRID or ISO-GRID Test System
Test Procedure
7112 Baird-Parker Agar
1. Prepare a sample homogenate. 7983 Egg Yolk Tellurite Emulsion (100 mL)
2. Filter 1 mL of homogenate through an ISO-GRID or 6810 1-Place Filtration Manifold
NEO-GRID hydrophobic grid membrane filter. 6800 3-Place Filtration Manifold
3. Place the membrane filter on Baird-Parker Egg Yolk Agar. 6801 6-Place Filtration Manifold
4. Incubate for 48 hours at 35 - 37°C. 6821 Rubber Tubing (10 feet)
Refer to the Methods Manual for complete instructions, and other 6822 Side-Arm Flask Assembly (1 L)
available test methods. 6824 Vacuum Pump - ¼ hp (Gast)
6828 Forceps
For Use With The NEO-GRID Test System Only
6848 NEO-GRID Test System - Contains 48 individually
packaged membrane filtration systems
6825 NEO-GRID Silicone Stopper
6826 Filta Tips (box of 100)
6827 Filter Bags - 24 oz Whirl-Pak (box of 250)
6829 1.0 mL Sterile Serological Pipettes (bag of 50)
For Use With The ISO-GRID Test System Only
Please see page 95 for the required ISO-GRID equipment and
accessories.

54 Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 • Fax: 517/372-2006 • www.neogen.com