Anda di halaman 1dari 54

CONTENTS PAGE

3.6/6 (7.2) kV XLPE/PVC 1 x (25 ~ 800) mm² A-1


6/10 (12) kV XLPE/PVC 1 x (25 ~ 800) mm² A-2
8.7/15 (17.5) kV XLPE/PVC 1 x (25 ~ 630) mm² A-3
12/20 (24) kV XLPE/PVC 1 x (35 ~ 630) mm² A-4
18/30 (36) kV XLPE/PVC 1 x (50 ~ 630) mm² A-5

3.6/6 (7.2) kV XLPE/PVC 3 x (25 ~ 300) mm² B-1


6/10 (12) kV XLPE/PVC 3 x (25 ~ 300) mm² B-2
8.7/15 (17.5) kV XLPE/PVC 3 x (25 ~ 300) mm² B-3
12/20 (24) kV XLPE/PVC 3 x (35 ~ 300) mm² B-4
18/30 (36) kV XLPE/PVC 3 x (50 ~ 240) mm² B-5

3.6/6 (7.2) kV XLPE/AWA/PVC 1 x (25 ~ 630) mm² C-1


6/10 (12) kV XLPE/AWA/PVC 1 x (25 ~ 630) mm² C-2
8.7/15 (17.5) kV XLPE/AWA/PVC 1 x (25 ~ 630) mm² C-3
12/20 (24) kV XLPE/AWA/PVC 1 x (35 ~ 630) mm² C-4
18/30 (36) kV XLPE/AWA/PVC 1 x (50 ~ 630) mm² C-5

3.6/6 (7.2) kV XLPE/SWA/PVC 3 x (25 ~ 300) mm² D-1


6/10 (12) kV XLPE/SWA/PVC 3 x (25 ~ 300) mm² D-2
8.7/15 (17.5) kV XLPE/SWA/PVC 3 x (25 ~ 300) mm² D-3
12/20 (24) kV XLPE/SWA/PVC 3 x (35 ~ 300) mm² D-4
18/30 (36) kV XLPE/SWA/PVC 3 x (50 ~ 240) mm² D-5

3.6/6 (7.2) kV XLPE/DATA/PVC 1 x (25 ~ 630) mm² E-1


6/10 (12) kV XLPE/DATA/PVC 1 x (25 ~ 630) mm² E-2
8.7/15 (17.5) kV XLPE/DATA/PVC 1 x (25 ~ 630) mm² E-3
12/20 (24) kV XLPE/DATA/PVC 1 x (35 ~ 630) mm² E-4
18/30 (36) kV XLPE/DATA/PVC 1 x (50 ~ 630) mm² E-5

3.6/6 (7.2) kV XLPE/DSTA/PVC 3 x (25 ~ 300) mm² F-1


6/10 (12) kV XLPE/DSTA/PVC 3 x (25 ~ 300) mm² F-2
8.7/15 (17.5) kV XLPE/DSTA/PVC 3 x (25 ~ 300) mm² F-3
12/20 (24) kV XLPE/DSTA/PVC 3 x (35 ~ 300) mm² F-4
18/30 (36) kV XLPE/DSTA/PVC 3 x (50 ~ 240) mm² F-5

3.6/6 (7.2) kV XLPE/FSWA/PVC 3 x (25 ~ 300) mm² G-1


6/10 (12) kV XLPE/FSWA/PVC 3 x (25 ~ 300) mm² G-2
8.7/15 (17.5) kV XLPE/FSWA/PVC 3 x (25 ~ 300) mm² G-3
12/20 (24) kV XLPE/FSWA/PVC 3 x (35 ~ 300) mm² G-4
18/30 (36) kV XLPE/FSWA/PVC 3 x (50 ~ 240) mm² G-5

Conditions of Current rating calculation H


Correction factor H-1 , H-2
Reduction Factors for groups of more than one multi-core cables in air to be applied
to the current-carrying capacity for one multi-core cable in free air I-1
Reduction Factors for groups of more than one circuit of single-core cables to be applied
to the current-carrying capacity for one circuit of singlei-core cables in free air I-2
Permissible Pulling tension J
Minimum Bending radius J
Permissible Side Wall pressure K
Calculation of Cable Pulling tension during installation K
Voltage drop K
SI
KABEL PT. SUMI INDO KABEL Tbk.
AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables


(3.6/6 kV ~ 18/30 kV ) XLPE/PVC 1 CORE

According to : IEC 60502-2

Copper Conductor

Conductor Screen

XLPE Insulation

Insulation Screen

Copper Tape Screen

BindingTape (manufacturer's option)

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(A)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/PVC 1 x (25 - 800) mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630 800
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 61 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3 34.3
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8 3.0 3.2 3.2 3.2
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. Of Outer sheath mm 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.5
Overall Diameter of cable mm 17.5 19.0 20.0 21.5 23.5 24.5 26.0 28.0 30.5 33.5 37.0 40.5 45.0 49.0
Weight of cable, approx. kg/km 503 614 743 962 1235 1480 1763 2113 2678 3305 4153 5235 6705 8410

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
(A-1)

Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376 0.0310
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596 0.605 0.637 0.715 0.797
Inductance (Trefoil) mH/km 0.406 0.385 0.369 0.348 0.33 0.317 0.308 0.301 0.291 0.285 0.28 0.273 0.268 0.260
Reactance (Trefoil) Ω/km 0.128 0.121 0.116 0.109 0.104 0.100 0.097 0.095 0.091 0.090 0.088 0.086 0.084 0.082
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740 * 840
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730 * 820
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080 * 1250
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235 * 1420
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080 * 1250
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8 112.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
6/10 (12) kV XLPE/PVC 1 x (25 - 800) mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630 800
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 61 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3 34.3
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. Of Outer sheath mm 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.0 2.2 2.2 2.4 2.5
Overall Diameter of cable mm 19.5 21.0 22.0 23.5 25.5 26.5 28.0 30.0 32.5 34.5 38.0 41.0 45.5 49.5
Weight of cable, approx. kg/km 568 682 815 1038 1315 1565 1853 2207 2784 3382 4217 5261 6734 8442

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21 21 21 21 21
(A-2)

Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376 0.0310
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500 1500 1000 1000 1000
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492 0.545 0.605 0.679 0.756
Inductance (Trefoil) mH/km 0.428 0.406 0.388 0.366 0.346 0.333 0.323 0.314 0.303 0.291 0.286 0.276 0.270 0.262
Reactance (Trefoil) Ω/km 0.134 0.127 0.122 0.115 0.109 0.104 0.101 0.099 0.095 0.091 0.090 0.087 0.085 0.082
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740 * 840
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730 * 820
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080 * 1250
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235 * 1420
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080 * 1250
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8 112.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/PVC 1 x (25 - 630) mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. Of Outer sheath mm 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.1 2.2 2.3 2.4
Overall Diameter of cable mm 22.0 23.0 24.0 25.5 27.5 29.0 30.5 32.0 34.5 37.0 40.0 43.5 48.0
Weight of cable, approx. kg/km 646 764 900 1128 1412 1665 1958 2332 2918 3525 4355 5427 6896

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
(A-3)

Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500 1500 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392 0.432 0.478 0.535
Inductance (Trefoil) mH/km 0.452 0.424 0.406 0.382 0.361 0.351 0.340 0.327 0.315 0.305 0.296 0.288 0.281
Reactance (Trefoil) Ω/km 0.142 0.133 0.127 0.120 0.113 0.110 0.107 0.103 0.099 0.096 0.093 0.090 0.088
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
12/20 (24) kV XLPE/PVC 1 x (35 - 630) mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 19 19 19 37 37 37 37 61 61 61 61
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. Of Outer sheath mm 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.2 2.3 2.4 2.5
Overall Diameter of cable mm 25.5 26.5 28.0 30.0 31.0 32.5 34.5 37.0 39.5 42.5 45.5 50.0
Weight of cable, approx. kg/km 853 992 1225 1516 1772 2085 2451 3045 3678 4518 5582 7088

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42 42 42 42
(A-4)

Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329 0.362 0.399 0.445
Inductance (Trefoil) mH/km 0.444 0.426 0.401 0.379 0.364 0.353 0.342 0.329 0.318 0.308 0.297 0.289
Reactance (Trefoil) Ω/km 0.140 0.134 0.126 0.119 0.114 0.111 0.108 0.103 0.100 0.097 0.093 0.091
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
18/30 (36) kV XLPE/PVC 1 x (50 - 630) mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 19 19 19 37 37 37 37 61 61 61 61
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. Of Outer sheath mm 2.0 2.0 2.1 2.1 2.2 2.2 2.3 2.4 2.5 2.6 2.7
Overall Diameter of cable mm 31.5 33.5 35.5 36.5 38.5 40.0 42.5 45.0 48.0 51.0 55.5
Weight of cable, approx. kg/km 1253 1499 1820 2088 2414 2795 3412 4046 4910 6023 7568

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63 63 63 63 63
(A-5)

Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225 0.246 0.269 0.295 0.327
Inductance (Trefoil) mH/km 0.460 0.437 0.412 0.397 0.387 0.372 0.357 0.344 0.332 0.320 0.310
Reactance (Trefoil) Ω/km 0.145 0.137 0.130 0.125 0.121 0.117 0.112 0.108 0.104 0.100 0.097
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * is typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
SI
KABEL PT. SUMI INDO KABEL Tbk.
AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables


(3.6/6 kV ~ 18/30 kV) XLPE/PVC 3 CORE

According to : IEC 60502-2

Copper Conductor
Conductor Screen

XLPE Insulation

Insulation Screen

Identification of core
(Red, Yellow, Blue by coloured tape)
Copper Tape Screen
Filler (Polyprophylene yarn, or extruded filler
upon request)
Binding Tape (manufacturer's option)

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(B)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Outer sheath mm 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3.0 3.2
Overall Diameter of cable mm 35.0 38.0 40.5 44.0 49.0 51.5 54.5 58.5 64.5 71.0
Weight of cable, approx. kg/km 1613 1992 2418 3133 4036 4832 5759 6900 8790 10829

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596
Inductance mH/km 0.363 0.342 0.328 0.311 0.296 0.287 0.279 0.271 0.264 0.259
Reactance Ω/km 0.114 0.107 0.103 0.098 0.093 0.090 0.088 0.085 0.083 0.082
Current Carrying Capacity :
- Buried direct **) A 129 153 181 221 262 298 334 377 434 489
in ground at 20°C
- In Air at 30°C A 142 170 204 253 304 351 398 455 531 606
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(B-1)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
6/10 (12) kV XLPE/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Outer sheath mm 2.2 2.3 2.4 2.5 2.7 2.8 2.9 3.0 3.1 3.3
Overall Diameter of cable mm 39.5 42.5 45.0 48.5 53.0 56.0 59.0 63.5 68.5 74.0
Weight of cable, approx. kg/km 1864 2260 2696 3433 4387 5203 6150 7350 9173 11160

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21
Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492
Inductance mH/km 0.389 0.367 0.352 0.332 0.315 0.305 0.296 0.287 0.277 0.269
Reactance Ω/km 0.122 0.115 0.110 0.104 0.099 0.096 0.093 0.090 0.087 0.084
Current Carrying Capacity :
- Buried direct **) A 129 153 181 221 262 298 334 377 434 489
in ground at 20°C
- In Air at 30°C A 142 170 204 253 304 351 398 455 531 606
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(B-2)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Outer sheath mm 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.3 3.5
Overall Diameter of cable mm 45.0 47.5 50.0 53.5 58.0 61.0 64.5 68.0 73.5 79.0
Weight of cable, approx. kg/km 2184 2598 3057 3818 4775 5608 6608 7800 9698 11718

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392
Inductance mH/km 0.415 0.391 0.374 0.353 0.334 0.323 0.314 0.303 0.292 0.283
Reactance Ω/km 0.130 0.123 0.118 0.111 0.105 0.102 0.098 0.095 0.092 0.089
Current Carrying Capacity :
- Buried direct **) A 129 153 181 221 262 298 334 377 434 489
in ground at 20°C
- In Air at 30°C A 142 170 204 253 304 351 398 455 531 606
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(B-3)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
12/20 (24) kV XLPE/PVC 3 x (35 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300
No. of Wire - 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Outer sheath mm 2.6 2.7 2.8 3.0 3.1 3.2 3.3 3.5 3.6
Overall Diameter of cable mm 52.5 55.0 58.5 63.5 66.5 69.5 73.5 78.5 84
Weight of cable, approx. kg/km 2995 3425 4213 5254 6110 7100 8323 10256 12280

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42
Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329
Inductance mH/km 0.412 0.395 0.372 0.352 0.340 0.329 0.318 0.306 0.295
Reactance Ω/km 0.129 0.124 0.117 0.110 0.107 0.103 0.100 0.096 0.093
Current Carrying Capacity :
- Buried direct **) A 153 181 221 262 298 334 377 434 489
in ground at 20°C
- In Air at 30°C A 170 204 253 304 351 398 455 531 606
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(B4)
XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables
18/30 (36) kV XLPE/PVC 3 x (50 - 240)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3
Nom. Cross-section area mm² 50 70 95 120 150 185 240
No. of Wire - 19 19 19 37 37 37 37
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Outer sheath mm 3.1 3.2 3.3 3.4 3.6 3.7 3.8
Overall Diameter of cable mm 67.0 71.0 75.0 78 81.5 85.5 90.5
Weight of cable, approx. kg/km 4504 5351 6405 7310 8348 9667 11645

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63
Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225
Inductance mH/km 0.436 0.411 0.388 0.375 0.362 0.35 0.335
Reactance Ω/km 0.137 0.129 0.122 0.118 0.114 0.110 0.105
Current Carrying Capacity :
- Buried direct **) A 181 221 262 298 334 377 434
in ground at 20°C
- In Air at 30°C A 204 253 304 351 398 455 531
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(B5)
SI
KABEL PT. SUMI INDO KABEL Tbk.
AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured


and PVC Sheathed Cables
(3.6/6 kV ~ 18/30 kV) XLPE/AWA/PVC

According to : IEC 60502-2

Copper Conductor

Conductor Screen

XLPE Insulation

Insulation Screen

Copper Tape Screen

Binding Tape (manufacturer's option)

PVC Separation Sheath


Round Aluminium Wire Armour

Binding Tape (manufacturer's option)

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(C)
XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/AWA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8 3.0 3.2 3.2
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.4
Nom. Diameter of Round Aluminium wire mm 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.5 2.5
Nom. Thick. of Outer sheath mm 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.1 2.2 2.3 2.5 2.6
Overall Diameter of cable mm 23.5 24.5 25.5 27.5 29.0 30.5 32.0 35.0 37.5 40.5 44.0 48.5 52.5
Weight of cable, approx. kg/km 798 927 1071 1314 1615 1875 2197 2663 3277 3958 4862 6183 7678

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
(C-1)

Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000 1000 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596 0.605 0.637 0.715
Inductance (Trefoil) mH/km 0.465 0.436 0.418 0.397 0.372 0.361 0.350 0.345 0.332 0.323 0.315 0.310 0.299
Reactance (Trefoil) Ω/km 0.146 0.137 0.131 0.125 0.117 0.113 0.110 0.108 0.104 0.101 0.099 0.097 0.094
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured and PVC Sheathed Cables
6/10 (12) kV XLPE/AWA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4
Nom. Diameter of Round Aluminium wire mm 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.5 2.5 2.5
Nom. Thick. of Outer sheath mm 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.1 2.2 2.3 2.4 2.5 2.6
Overall Diameter of cable mm 25.5 26.5 27.5 29.5 31.0 33.5 35.0 37.0 39.5 42.0 45.5 49.0 53.0
Weight of cable, approx. kg/km 889 1022 1169 1416 1722 2084 2413 2795 3414 4079 5088 6212 7722

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21 21 21 21
(C-2)

Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492 0.545 0.605 0.679
Inductance (Trefoil) mH/km 0.481 0.452 0.433 0.411 0.385 0.379 0.368 0.356 0.343 0.330 0.322 0.312 0.300
Reactance (Trefoil) Ω/km 0.151 0.142 0.136 0.129 0.121 0.119 0.115 0.112 0.108 0.104 0.101 0.098 0.094
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/AWA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.4 1.4
Nom. Diameter of Round Aluminium wire mm 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 2.5
Nom. Thick. of Outer sheath mm 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.2 2.3 2.3 2.5 2.6 2.7
Overall Diameter of cable mm 27.5 29.0 30.0 31.5 34.5 36.0 37.5 39.0 41.5 44.0 48.0 51.5 55.5
Weight of cable, approx. kg/km 1000 1137 1287 1553 1948 2239 2556 2961 3589 4244 5286 6457 7950

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
(C-3)

Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500 1500 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392 0.432 0.478 0.535
Inductance (Trefoil) mH/km 0.496 0.470 0.450 0.424 0.407 0.394 0.381 0.367 0.352 0.339 0.332 0.322 0.310
Reactance (Trefoil) Ω/km 0.156 0.148 0.142 0.133 0.128 0.124 0.120 0.115 0.111 0.107 0.104 0.101 0.097
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured and PVC Sheathed Cables
12/20 (24) kV XLPE/AWA/PVC 1 x (35 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4 1.5
Nom. Diameter of Round Aluminium wire mm 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5
Nom. Thick. of Outer sheath mm 1.9 2.0 2.1 2.1 2.2 2.2 2.3 2.3 2.5 2.6 2.7 2.8
Overall Diameter of cable mm 31.0 32.5 35.0 37.0 38.5 39.5 41.5 44.0 47.5 51.0 54.0 58.0
Weight of cable, approx. kg/km 1258 1426 1775 2105 2402 2725 3137 3764 4606 5507 6678 8224

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42 42 42 42
(C-4)

Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329 0.362 0.399 0.445
Inductance (Trefoil) mH/km 0.483 0.467 0.445 0.412 0.407 0.392 0.379 0.364 0.355 0.344 0.331 0.318
Reactance (Trefoil) Ω/km 0.152 0.147 0.140 0.132 0.128 0.123 0.119 0.114 0.111 0.108 0.104 0.100
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Round Aluminium Wire Armoured and PVC Sheathed Cables
18/30 (36) kV XLPE/AWA/PVC 1 x (50 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.5 1.6
Nom. Diameter of Round Aluminium wire mm 2.0 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Nom. Thick. of Outer sheath mm 2.2 2.2 2.3 2.3 2.4 2.5 2.6 2.6 2.7 2.8 3.0
Overall Diameter of cable mm 38.5 40.5 42.5 43.5 46.0 48.0 50.5 53.0 56.0 59.5 64.0
Weight of cable, approx. kg/km 1878 2151 2506 2797 3287 3727 4402 5114 6040 7243 8854

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63 63 63 63 63
(C-5)

Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225 0.246 0.269 0.295 0.327
Inductance (Trefoil) mH/km 0.500 0.474 0.448 0.432 0.422 0.408 0.392 0.377 0.363 0.350 0.338
Reactance (Trefoil) Ω/km 0.157 0.149 0.141 0.136 0.133 0.128 0.123 0.118 0.114 0.110 0.106
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
SI PT. SUMI INDO KABEL Tbk.
KABEL

AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured
and PVC Sheathed Cables
(3.6/6 kV ~ 18/30 kV) XLPE/SWA/PVC

According to : IEC 60502-2

Copper Conductor
Conductor Screen
XLPE Insulation
Insulation Screen
Identification tape
(Red, Yellow, Blue by coloured tape)
Copper Tape Screen
Filler (Polyprophylene yarn, or extruded filler
upon request)
Binding Tape (manufacturer's option)
Separation Sheath

Galvanized Round Steel Wire Armour


Binding Tape (manufacturer's option)

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(D)
XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/SWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8
Nom. Diameter of Round Steel wire mm 2.0 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.15 3.15
Nom. Thick. of Outer sheath mm 2.3 2.4 2.5 2.6 2.7 2.9 3.0 3.1 3.3 3.5
Overall Diameter of cable mm 41.5 45.0 47.5 51.5 55.5 59.0 62.5 66.0 73.0 80.0
Weight of cable, approx. kg/km 3018 3870 4386 5334 6414 7432 8521 9814 12718 15198

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596
Inductance mH/km 0.363 0.342 0.328 0.311 0.296 0.287 0.279 0.271 0.264 0.259
Reactance Ω/km 0.114 0.107 0.103 0.098 0.093 0.090 0.088 0.085 0.083 0.082
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(D-1)
XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured and PVC Sheathed Cables
6/10 (12) kV XLPE/SWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9
Nom. Diameter of Round Steel wire mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.15 3.15
Nom. Thick. of Outer sheath mm 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.4 3.6
Overall Diameter of cable mm 47.0 50.0 52.5 56.5 60.5 64.0 67.0 70.5 77.5 83.5
Weight of cable, approx. kg/km 3848 4372 4925 5903 7010 8023 9076 10421 13402 15769

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21
Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492
Inductance mH/km 0.389 0.367 0.352 0.332 0.315 0.305 0.296 0.287 0.277 0.269
Reactance Ω/km 0.122 0.115 0.110 0.104 0.099 0.096 0.093 0.090 0.087 0.084
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(D-2)
XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/SWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0
Nom. Diameter of Round Steel wire mm 2.5 2.5 2.5 2.5 2.5 2.5 3.15 3.15 3.15 3.15
Nom. Thick. of Outer sheath mm 2.6 2.7 2.8 2.9 3.1 3.2 3.3 3.4 3.6 3.8
Overall Diameter of cable mm 52.0 55.0 57.5 61.0 65.5 68.5 73.0 77.5 83.0 88.5
Weight of cable, approx. kg/km 4388 4937 5546 6484 7687 8656 10533 12027 14242 16607

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392
Inductance mH/km 0.415 0.391 0.374 0.353 0.334 0.323 0.314 0.303 0.292 0.283
Reactance Ω/km 0.130 0.123 0.118 0.111 0.105 0.102 0.098 0.095 0.092 0.089
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(D-3)
XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured and PVC Sheathed Cables
12/20 (24) kV XLPE/SWA/PVC 3 x (35 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300
No. of Wire - 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.5 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1
Nom. Diameter of Round Steel wire mm 2.5 2.5 2.5 2.5 3.15 3.15 3.15 3.15 3.15
Nom. Thick. of Outer sheath mm 2.9 3.0 3.1 3.2 3.4 3.6 3.6 3.8 3.9
Overall Diameter of cable mm 60.5 63.0 66.5 70.5 75.5 78.5 82.5 88.0 93.5
Weight of cable, approx. kg/km 5600 6228 7166 8332 10206 11400 12866 15143 17550

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42
Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329
Inductance mH/km 0.412 0.395 0.372 0.352 0.340 0.329 0.318 0.306 0.295
Reactance Ω/km 0.129 0.124 0.117 0.110 0.107 0.103 0.100 0.096 0.093
Current Carrying Capacity :
- Buried direct **) A 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(D-4)
XLPE Insulated, Copper Tape Shielded, Galvanized Round Steel Wire Armoured and PVC Sheathed Cables
18/30 (36) kV XLPE/SWA/PVC 3 x (50 - 240)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3
Nom. Cross-section area mm² 50 70 95 120 150 185 240
No. of Wire - 19 19 19 37 37 37 37
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.8 1.8 1.9 2.0 2.0 2.1 2.2
Nom. Diameter of Round Steel wire mm 3.15 3.15 3.15 3.15 3.15 3.15 3.15
Nom. Thick. of Outer sheath mm 3.4 3.5 3.7 3.8 3.9 4.0 4.2
Overall Diameter of cable mm 76.0 80.0 84.5 87.5 91.0 95.0 100.5
Weight of cable, approx. kg/km 8667 9720 11084 12168 13415 15010 17359

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63
Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225
Inductance mH/km 0.436 0.411 0.388 0.375 0.362 0.350 0.335
Reactance Ω/km 0.137 0.129 0.122 0.118 0.114 0.110 0.105
Current Carrying Capacity :
- Buried direct **) A 181 220 263 298 332 374 431
in ground at 20°C
- In Air at 30°C A 205 253 307 352 397 453 529
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(D-5)
SI
KABEL PT. SUMI INDO KABEL Tbk.
AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured


and PVC Sheathed Cables
(3.6/6 kV ~ 18/30 kV) XLPE/DATA/PVC

According to : IEC 60502-2

Copper Conductor

Conductor Screen

XLPE Insulation

Insulation Screen
Copper Tape Screen

Binding Tape (manufacturer's option)

PVC Separation Sheath

Double Aluminium Tape Armour

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(E)
XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/DATA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8 3.0 3.2 3.2
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.4
Nom. Thickness of Aluminium tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.1 2.3 2.4 2.5
Overall Diameter of cable mm 21.5 23.0 24.0 25.5 27.5 28.5 30.0 32.0 34.5 37.5 41.0 45.0 49.5
Weight of cable, approx. kg/km 713 837 978 1214 1507 1766 2065 2448 3058 3720 4608 5734 7282

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
(E-1)

Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000 1000 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596 0.605 0.637 0.715
Inductance (Trefoil) mH/km 0.447 0.424 0.406 0.382 0.361 0.347 0.337 0.327 0.315 0.307 0.301 0.295 0.287
Reactance (Trefoil) Ω/km 0.140 0.133 0.127 0.120 0.113 0.109 0.106 0.103 0.099 0.097 0.095 0.093 0.090
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured and PVC Sheathed Cables
6/10 (12) kV XLPE/DATA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4
Nom. Thickness of Aluminium tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.1 2.2 2.3 2.4 2.5
Overall Diameter of cable mm 23.5 25.5 26.0 27.5 29.5 30.5 32.5 34.0 36.5 39 42.0 45.5 50.0
Weight of cable, approx. kg/km 800 927 1070 1310 1610 1874 2191 2581 3170 3813 4685 5765 7315

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21 21 21 21
(E-2)

Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492 0.545 0.605 0.679
Inductance (Trefoil) mH/km 0.465 0.444 0.422 0.397 0.375 0.361 0.353 0.339 0.327 0.315 0.306 0.297 0.289
Reactance (Trefoil) Ω/km 0.146 0.140 0.133 0.125 0.118 0.113 0.111 0.107 0.103 0.099 0.096 0.093 0.091
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/DATA/PVC 1 x (25 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.4 1.4
Nom. Thickness of Aluminium tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.2 2.3 2.4 2.5 2.6
Overall Diameter of cable mm 26.0 27.0 28.0 29.5 32.0 33.0 34.5 36.5 39.0 41.5 44.5 48.0 52.5
Weight of cable, approx. kg/km 902 1033 1180 1426 1745 2013 2337 2718 3332 3985 4848 5982 7528

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
(E-3)

Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500 1500 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392 0.432 0.478 0.535
Inductance (Trefoil) mH/km 0.485 0.456 0.437 0.411 0.392 0.376 0.365 0.354 0.340 0.328 0.317 0.307 0.299
Reactance (Trefoil) Ω/km 0.152 0.143 0.137 0.129 0.123 0.118 0.115 0.111 0.107 0.103 0.100 0.097 0.094
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 140 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 144 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 163 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 196 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 167 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured and PVC Sheathed Cables
12/20 (24) kV XLPE/DATA/PVC 1 x (35 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 7 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4 1.5
Nom. Thickness of Aluminium tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 1.9 1.9 2.0 2.0 2.1 2.1 2.2 2.3 2.4 2.5 2.6 2.7
Overall Diameter of cable mm 29.5 30.5 32.0 34.0 35.5 37.0 39.0 41.5 44.0 47.0 50.5 55.0
Weight of cable, approx. kg/km 1146 1296 1562 1874 2162 2475 2878 3502 4165 5040 6187 7776

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42 42 42 42
(E-4)

Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500 1500
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329 0.362 0.399 0.445
Inductance (Trefoil) mH/km 0.473 0.454 0.427 0.404 0.391 0.379 0.367 0.352 0.339 0.328 0.318 0.308
Reactance (Trefoil) Ω/km 0.149 0.143 0.134 0.127 0.123 0.119 0.115 0.111 0.107 0.103 0.100 0.097
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 166 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 172 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 198 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 238 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 203 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
XLPE Insulated, Copper Tape Shielded, Double Aluminium Tape Armoured and PVC Sheathed Cables
18/30 (36) kV XLPE/DATA/PVC 1 x (50 - 630)mm²

CONSTRUCTION DATA
No. of Core - 1 1 1 1 1 1 1 1 1 1 1
Nom. Cross-section area mm² 50 70 95 120 150 185 240 300 400 500 630
No. of Wire - 19 19 19 37 37 37 37 61 61 61 91
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7 23.4 26.5 30.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.5 1.6
Nom. Thickness of Aluminium tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 2.1 2.2 2.2 2.3 2.3 2.4 2.5 2.5 2.6 2.7 2.9
Overall Diameter of cable mm 36.0 37.5 39.5 41.0 42.5 44.5 47.0 49.5 52.5 56.0 61.0
Weight of cable, approx. kg/km 1632 1913 2241 2543 2888 3288 3934 4620 5520 6698 8357

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63 63 63 63 63
(E-5)

Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779 0.0614 0.0482 0.0376
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225 0.246 0.269 0.295 0.327
Inductance (Trefoil) mH/km 0.487 0.459 0.434 0.420 0.406 0.393 0.377 0.363 0.350 0.338 0.329
Reactance (Trefoil) Ω/km 0.153 0.144 0.136 0.132 0.128 0.124 0.119 0.114 0.110 0.106 0.103
Current Carrying Capacity :
- Buried direct in ground at 20°C **) (Trefoil) A 196 239 285 323 361 406 469 526 590 * 655 * 740
(Flat spaced) A 203 246 293 332 366 410 470 524 572 * 650 * 730
- In Air at 30°C (Trefoil) A 238 296 361 417 473 543 641 735 845 * 940 * 1080
(Flat spaced) A 286 356 434 500 559 637 745 846 938 * 1075 * 1235
(Flat touching) A 243 303 369 426 481 550 647 739 837 * 945 * 1080
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3 56.4 70.5 88.8
*) Diameter compacted shape * typical data
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m
SI PT. SUMI INDO KABEL Tbk.
KABEL

AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured
and PVC Sheathed Cables
(3.6/6 kV ~ 18/30 kV) XLPE/DSTA/PVC

According to : IEC 60502-2

Copper Conductor
Conductor Screen
XLPE Insulation
Insulation Screen
Identification of core
(Red, Yellow, Blue by coloured tape)
Copper Tape Screen

Filler (Polyprophylene yarn, or extruded filler


upon request)
Binding Tape (manufacturer's option)

PVC Separation Sheath

Double Galvanized Steel Tape Armour

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(F)
XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/DSTA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8
Nom. Thick. of Steel tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 2.2 2.3 2.4 2.5 2.6 2.8 2.9 3.0 3.2 3.4
Overall Diameter of cable mm 38.5 41.5 43.5 47.5 52.0 55.5 58.5 62.5 68.0 75.0
Weight of cable, approx. kg/km 2370 2829 3283 4100 5096 6009 7036 8268 10226 12443

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596
Inductance mH/km 0.363 0.342 0.328 0.311 0.296 0.287 0.279 0.271 0.264 0.259
Reactance Ω/km 0.114 0.107 0.103 0.098 0.093 0.090 0.088 0.085 0.083 0.082
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(F-1)
XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured and PVC Sheathed Cables
6/10 (12) kV XLPE/DSTA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9
Nom. Thick. of Steel tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nom. Thick. of Outer sheath mm 2.4 2.4 2.6 2.7 2.8 2.9 3.0 3.1 3.3 3.5
Overall Diameter of cable mm 43.5 46.0 48.5 52.5 57.0 60.0 63.0 67.0 72.5 78.0
Weight of cable, approx. kg/km 2739 3170 3705 4552 5575 6484 7502 8727 10734 12883

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21
Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492
Inductance mH/km 0.389 0.367 0.352 0.332 0.315 0.305 0.296 0.287 0.277 0.269
Reactance Ω/km 0.122 0.115 0.110 0.104 0.099 0.096 0.093 0.090 0.087 0.084
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(F-2)
( )

XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/DSTA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0
Nom. Thick. of Steel tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8
Nom. Thick. of Outer sheath mm 2.5 2.6 2.7 2.8 3 3.1 3.2 3.3 3.5 3.7
Overall Diameter of cable mm 48.5 51.0 54.0 57.5 62.0 65.0 68.0 72.0 78.0 84.5
Weight of cable, approx. kg/km 3169 3646 4180 5021 6132 7005 8041 9355 11411 14441

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392
Inductance mH/km 0.415 0.391 0.374 0.353 0.334 0.323 0.314 0.303 0.292 0.283
Reactance Ω/km 0.130 0.123 0.118 0.111 0.105 0.102 0.098 0.095 0.092 0.089
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(F-3)
XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured and PVC Sheathed Cables
12/20 (24) kV XLPE/DSTA/PVC 3 x (35 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300
No. of Wire - 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.5 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1
Nom. Thick. of Steel tape mm 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.8
Nom. Thick. of Outer sheath mm 2.8 2.9 3.0 3.1 3.2 3.3 3.5 3.7 3.8
Overall Diameter of cable mm 56.5 59.0 63.0 67.0 70.0 73.5 77.5 84.0 90.0
Weight of cable, approx. kg/km 4161 4712 5585 6637 7591 8650 10030 12964 15217

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42
Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0779
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329
Inductance mH/km 0.412 0.395 0.372 0.352 0.340 0.329 0.318 0.306 0.295
Reactance Ω/km 0.129 0.124 0.117 0.110 0.107 0.103 0.100 0.096 0.093
Current Carrying Capacity :
- Buried direct **) A 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(F-4)
( )

XLPE Insulated, Copper Tape Shielded, Double Galvanized Steel Tape Armoured and PVC Sheathed Cables
18/30 (36) kV XLPE/DSTA/PVC 3 x (50 - 240)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3
Nom. Cross-section area mm² 50 70 95 120 150 185 240
No. of Wire - 19 19 19 37 37 37 37
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.8 1.8 1.9 2.0 2.0 2.1 2.2
Nom. Thick. of Steel tape mm 0.5 0.5 0.5 0.8 0.8 0.8 0.8
Nom. Thick. of Outer sheath mm 3.3 3.4 3.5 3.7 3.8 3.9 4.1
Overall Diameter of cable mm 71.0 75.0 79.5 83.5 87.0 91.0 96.5
Weight of cable, approx. kg/km 6037 6965 8156 10040 11186 12643 14891

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63
Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225
Inductance mH/km 0.436 0.411 0.388 0.375 0.362 0.350 0.335
Reactance Ω/km 0.137 0.129 0.122 0.118 0.114 0.110 0.105
Current Carrying Capacity :
- Buried direct **) A 181 220 263 298 332 374 431
in ground at 20°C
- In Air at 30°C A 205 253 307 352 397 453 529
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(F-5)
SI PT. SUMI INDO KABEL Tbk.
KABEL

AFFILIATE OF
SUMITOMO ELECTRIC INDUSTRIES,LTD - JAPAN

XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured
and PVC Sheathed Cables
(3.6/6 kV ~ 18/30 kV) XLPE/FSWA/PVC

According to : IEC 60502-2

Copper Conductor
Conductor Screen
XLPE Insulation
Insulation Screen
Identification of core
(Red, Yellow, Blue by coloured tape)
Copper Tape Screen

Filler (Polyprophylene yarn, or extruded filler


upon request)
Binding Tape (manufacturer's option)
PVC Separation Sheath
Galvanized Flat Steel Wire Armour
Galvanized Steel Tape binding

PVC Sheath (Red or Black colour)

Note : Special application upon request


* Available product in accordance to : SPLN, ICEA/NEMA,
AS standard or other requirement.
* Flame retardant test acc to IEC 60332-3
Cat. A, B or C.
* Longitudinally Water blocking characteristic.
* Anti termite performance.
* Tin coated Copper conductor.
* Copper wire screen.
* Polyethylene / Low smoke Halogen Free
sheath.

(G)
XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured and PVC Sheathed Cables
3.6/6 (7.2) kV XLPE/FSWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.8
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8
Nom. Thick. of Flat Steel wire mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Nom. Thick. of Steel tape mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Nom. Thick. of Outer sheath mm 2.2 2.3 2.4 2.5 2.6 2.7 2.9 3.0 3.2 3.3
Overall Diameter of cable mm 39.0 42.0 44.0 48.0 52.0 55.5 59.0 63.0 68.5 75.0
Weight of cable, approx. kg/km 2549 3003 3455 4277 5292 6188 7247 8503 10463 12685

ELECTRICAL DATA
AC Voltage test for 5 min. kV 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
Partial Discharge test at max. 10ρC kV 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23 6.23
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 2500 2000 2000 2000 1500 1500 1500 1500 1000 1000
Capacitance µF/km 0.258 0.291 0.318 0.361 0.413 0.448 0.485 0.531 0.573 0.596
Inductance mH/km 0.363 0.342 0.328 0.311 0.296 0.287 0.279 0.271 0.264 0.259
Reactance Ω/km 0.114 0.107 0.103 0.098 0.093 0.090 0.088 0.085 0.083 0.082
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(G-1)
XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured and PVC Sheathed Cables
6/10 (12) kV XLPE/FSWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9
Nom. Thick. of Flat Steel wire mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.8 0.8 0.8
Nom. Thick. of Steel tape mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Nom. Thick. of Outer sheath mm 2.3 2.4 2.5 2.7 2.8 2.9 3.0 3.1 3.3 3.4
Overall Diameter of cable mm 43.5 46.5 48.5 52.5 57.0 60.0 63.5 67.0 72.5 78.0
Weight of cable, approx. kg/km 2915 3362 3848 4742 5784 6702 7729 8978 10990 13130

ELECTRICAL DATA
AC Voltage test for 5 min. kV 21 21 21 21 21 21 21 21 21 21
Partial Discharge test at max. 10ρC kV 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38 10.38
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3000 2500 2500 2000 2000 2000 2000 1500 1500 1500
Capacitance µF/km 0.202 0.226 0.246 0.278 0.315 0.341 0.368 0.401 0.446 0.492
Inductance mH/km 0.389 0.367 0.352 0.332 0.315 0.305 0.296 0.287 0.277 0.269
Reactance Ω/km 0.122 0.115 0.110 0.104 0.099 0.096 0.093 0.090 0.087 0.084
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(G-2)
XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured and PVC Sheathed Cables
8.7/15 (17.5) kV XLPE/FSWA/PVC 3 x (25 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 25 35 50 70 95 120 150 185 240 300
No. of Wire - 7 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 5.9 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0
Nom. Thick. of Flat Steel wire mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Nom. Thick. of Steel tape mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Nom. Thick. of Outer sheath mm 2.5 2.6 2.7 2.8 2.9 3.1 3.2 3.3 3.5 3.6
Overall Diameter of cable mm 48.5 51.5 54.0 57.5 62.0 65.0 68.5 72.5 78.0 83.5
Weight of cable, approx. kg/km 3334 3826 4377 5221 6320 7233 8278 9614 11699 13875

ELECTRICAL DATA
AC Voltage test for 5 min. kV 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
Partial Discharge test at max. 10ρC kV 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1 15.1
DC Resistance at 20°C Ω/km 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.927 0.669 0.494 0.343 0.247 0.197 0.160 0.1281 0.0984 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3000 3000 2500 2500 2500 2000 2000 2000 1500
Capacitance µF/km 0.168 0.186 0.202 0.226 0.255 0.275 0.296 0.322 0.356 0.392
Inductance mH/km 0.415 0.391 0.374 0.353 0.334 0.323 0.314 0.303 0.292 0.283
Reactance Ω/km 0.130 0.123 0.118 0.111 0.105 0.102 0.098 0.095 0.092 0.089
Current Carrying Capacity :
- Buried direct **) A 129 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 143 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 3.5 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(G-3)
XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured and PVC Sheathed Cables
12/20 (24) kV XLPE/FSWA/PVC 3 x (35 - 300)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3 3 3
Nom. Cross-section area mm² 35 50 70 95 120 150 185 240 300
No. of Wire - 7 19 19 19 37 37 37 37 61
Diameter of Conductor, approx. *) mm 7.1 8.1 9.7 11.6 12.9 14.3 16.0 18.3 20.7
Nom. Thick. of Insulation mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.5 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1
Nom. Thick. of Flat Steel wire mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Nom. Thick. of Steel tape mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Nom. Thick. of Outer sheath mm 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.6 3.8
Overall Diameter of cable mm 57.0 59.5 63.0 67.0 70.5 73.5 77.5 83.0 88.5
Weight of cable, approx. kg/km 4373 4917 5817 6889 7852 8919 10287 12383 14601

ELECTRICAL DATA
AC Voltage test for 5 min. kV 42 42 42 42 42 42 42 42 42
Partial Discharge test at max. 10ρC kV 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76 20.76
DC Resistance at 20°C Ω/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
AC Resistance at 90°C Ω/km 0.669 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972 0.0799
Insulation Resistance at 20°C Μ.Ω.km 3500 3500 3000 3000 2500 2500 2500 2000 2000
Capacitance µF/km 0.161 0.174 0.194 0.218 0.234 0.251 0.272 0.300 0.329
Inductance mH/km 0.412 0.395 0.372 0.352 0.340 0.329 0.318 0.306 0.295
Reactance Ω/km 0.129 0.124 0.117 0.110 0.107 0.103 0.100 0.096 0.093
Current Carrying Capacity :
- Buried direct **) A 154 181 220 263 298 332 374 431 482
in ground at 20°C
- In Air at 30°C A 172 205 253 307 352 397 453 529 599
Short circuit current rating at 1 sec. (approx.) kA 4.9 7.0 9.8 13.3 16.9 21.1 26.0 33.8 42.3
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(G-4)
XLPE Insulated, Copper Tape Shielded, Galvanized Flat Steel Wire Armoured and PVC Sheathed Cables
18/30 (36) kV XLPE/FSWA/PVC 3 x (50 - 240)mm²

CONSTRUCTION DATA
No. of Core - 3 3 3 3 3 3 3
Nom. Cross-section area mm² 50 70 95 120 150 185 240
No. of Wire - 19 19 19 37 37 37 37
Diameter of Conductor, approx. *) mm 8.1 9.7 11.6 12.9 14.3 16.0 18.3
Nom. Thick. of Insulation mm 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Nom. Thick. of Copper tape mm 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Nom. Thick. of Separation sheath mm 1.8 1.8 1.9 2.0 2.0 2.1 2.2
Nom. Thick. of Flat Steel wire mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Nom. Thick. of Steel tape mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Nom. Thick. of Outer sheath mm 3.3 3.4 3.5 3.6 3.7 3.8 4.0
Overall Diameter of cable mm 71.5 75.0 79.5 82.5 85.5 89.5 95.5
Weight of cable, approx. kg/km 6286 7241 8448 9469 10551 11986 14176

ELECTRICAL DATA
AC Voltage test for 5 min. kV 63 63 63 63 63 63 63
Partial Discharge test at max. 10ρC kV 31.1 31.1 31.1 31.1 31.1 31.1 31.1
DC Resistance at 20°C Ω/km 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754
AC Resistance at 90°C Ω/km 0.494 0.343 0.247 0.196 0.159 0.1272 0.0972
Insulation Resistance at 20°C Μ.Ω.km 4500 4000 3500 3500 3000 3000 2500
Capacitance µF/km 0.136 0.151 0.167 0.179 0.191 0.206 0.225
Inductance mH/km 0.436 0.411 0.388 0.375 0.362 0.350 0.335
Reactance Ω/km 0.137 0.129 0.122 0.118 0.114 0.110 0.105
Current Carrying Capacity :
- Buried direct **) A 181 220 263 298 332 374 431
in ground at 20°C
- In Air at 30°C A 205 253 307 352 397 453 529
Short circuit current rating at 1 sec. (approx.) kA 7.0 9.8 13.3 16.9 21.1 26.0 33.8
Note : *) Diameter compacted shape
**) Thermal resistivity of soil : 1.5°K.m / W
Depth of laying = 0.8 m

(G-5)
CURRENT CARRYING CAPACITY ACCORDING TO IEC 60502-2 : 2005

Current rating of cable is calculated under the following conditions :


Maximum conductor
90°C
temperature
Basic ambient In Air 30°C
temperature Underground 20°C
Thermal resistivity of soil 1.5 K.m/W
Depth of laying, underground 80 cm
Three single-core cable

Trefoil

In Air ≥ 0 .5 x D

Flat

≥ 0 .5 x D ≥ 0 .5 x D
Flat spaced Flat touching

Cable Trefoil
arrangement
( D : Overall dia.) Under-
ground

Flat

D D
One three-core cable

In Air

≥ 0.3 x D

Underground

(H)
CORRECTION FACTOR

Correction factors for ambient Air temperatures


Max.conductor Ambient air temperature
temperature °C
°C 20 25 30 35 40 45 50 55 60
90 1.08 1.04 1 0.96 0.91 0.87 0.82 0.76 0.71

Correction factors for ambient Ground temperatures


Max.conductor Ambient Ground temperature
temperature °C
°C 10 15 20 25 30 35 40 45 50
90 1.07 1.04 1 0.96 0.93 0.89 0.85 0.80 0.76

Correction factors for depths of laying for direct buried cables


Single-core cables
Depth of laying Nominal conductor size Three-core
m mm² cables
≤ 185 mm² ≥ 185 mm²
0.5 1.04 1.06 1.04
0.6 1.02 1.04 1.03
0.8 1 1 1

1 0.98 0.97 0.98


1.25 0.96 0.95 0.96
1.5 0.95 0.93 0.95

1.75 0.94 0.91 0.94


2 0.93 0.90 0.93
2.5 0.91 0.88 0.91
3 0.90 0.86 0.90

( H-1 )
CORRECTION FACTOR

Correction factors for soil thermal resistivities for Direct buried Single-core cables
Nominal area Values of soil thermal resistivity
of conductor K.m/W
mm² 0.7 0.8 0.9 1 1.5 2 2.5 3
16 1.29 1.24 1.19 1.15 1 0.89 0.82 0.75
25 1.30 1.25 1.20 1.16 1 0.89 0.81 0.75
35 1.30 1.25 1.21 1.16 1 0.89 0.81 0.75
50 1.32 1.26 1.21 1.16 1 0.89 0.81 0.74

70 1.33 1.27 1.22 1.17 1 0.89 0.81 0.74


95 1.34 1.28 1.22 1.18 1 0.89 0.80 0.74
120 1.34 1.28 1.22 1.18 1 0.88 0.80 0.74
150 1.35 1.28 1.23 1.18 1 0.88 0.80 0.74

185 1.35 1.29 1.23 1.18 1 0.88 0.80 0.74


240 1.36 1.29 1.23 1.18 1 0.88 0.80 0.73
300 1.36 1.30 1.24 1.19 1 0.88 0.80 0.73
400 1.37 1.30 1.24 1.19 1 0.88 0.79 0.73

Correction factors for soil thermal resistivities for Direct buried Three-core cables
Nominal area Values of soil thermal resistivity
of conductor K.m/W
mm² 0.7 0.8 0.9 1 1.5 2 2.5 3
16 1.23 1.19 1.16 1.12 1 0.91 0.84 0.78
25 1.24 1.20 1.16 1.13 1 0.91 0.84 0.78
35 1.25 1.21 1.17 1.13 1 0.91 0.83 0.78
50 1.25 1.21 1.17 1.14 1 0.91 0.83 0.77

70 1.26 1.21 1.18 1.14 1 0.90 0.83 0.77


95 1.26 1.22 1.18 1.14 1 0.90 0.83 0.77
120 1.26 1.22 1.18 1.14 1 0.90 0.83 0.77
150 1.27 1.22 1.18 1.15 1 0.90 0.83 0.77

185 1.27 1.23 1.18 1.15 1 0.90 0.83 0.77


240 1.28 1.23 1.19 1.15 1 0.90 0.83 0.77
300 1.28 1.23 1.19 1.15 1 0.90 0.82 0.77
400 1.28 1.23 1.19 1.15 1 0.90 0.82 0.76

( H-2 )
Reduction factors for groups of more than one multi-core cables in air to be applied to
the current -carrying capacity for one multi-core cable in free air
Number Number of cables
Method of installation
of trays 1 2 3 4 6 9
Touching 1 1.00 0.88 0.82 0.79 0.76 0.73

2 1.00 0.87 0.80 0.77 0.73 0.68

≥ 20 mm
Cables on 3 1.00 0.86 0.79 0.76 0.71 0.66
perforated trays Spaced 1 1.00 1.00 0.98 0.95 0.91 -
D

2 1.00 0.99 0.96 0.92 0.87 -

≥ 20 mm 3 1.00 0.98 0.95 0.91 0.85 -


225 mm
1 1.00 0.88 0.82 0.78 0.73 0.72

2 1.00 0.88 0.81 0.76 0.71 0.70

Cables on vertical Touching

perforated trays

225 mm
1 1.00 0.91 0.89 0.88 0.87 -

D
2 1.00 0.91 0.88 0.87 0.85 -

Spaced
Touching 1 1.00 0.87 0.82 0.80 0.79 0.78

2 1.00 0.86 0.80 0.78 0.76 0.73

≥ 20 mm
Cables on ladder 3 1.00 0.85 0.79 0.76 0.73 0.70
supports,cleats, Spaced 1 1.00 1.00 1.00 1.00 1.00 -
D
etc.
2 1.00 0.99 0.98 0.97 0.96 -

≥ 20 mm
3 1.00 0.98 0.97 0.96 0.93 -
NOTE 1 Value given are averages for the cable types and range of conductor sizes considered. The spread of values is generally less than 5 %

NOTE 2 Factors apply to single layer groups of cables as shown above and do not apply when cables are installed in more than one layer touching
each other. Values for such installations may be significantly lower and must be determined by an appropriate method.

NOTE 3 Values are given for vertical spacings between trays of 300 mm and at least 20 mm between trays and wall. For closer spacing, the factors
should be reduced.

NOTE 4 Values are given for horizontal spacings between trays of 225 mm with trays mounted back to back. For closer spacing, the factors should be
reduced.

( I-1 )
Reduction factors for groups of more than one circuit of single-core cables (Note 2) - To be applied to
the current -carrying capacity for one circuit of single-core cables in free air
Number of Use as a multiplier to
Method of installation
trays 1 2 3 rating for
Touching 1 0.98 0.91 0.87
Perforated Three cables in
trays 2 0.96 0.87 0.81 horizontal
(Note 3) formation
≥ 20 mm
3 0.95 0.85 0.78
Touching 1 1.00 0.97 0.96
Ladder Three cables in
supports,cleats etc. 2 0.98 0.93 0.89 horizontal
(Note 3) formation
≥ 20 mm
3 0.97 0.90 0.86
1 1.00 0.98 0.96
D
≥ 2D
Perforated
trays 2 0.97 0.93 0.89

≥ 20 mm
3 0.96 0.92 0.86


225 mm
Vertical 1 1.00 0.91 0.89 Three cables in
≥ 2D
perforated trays trefoil formation
(Note 4) 2 1.00 0.90 0.86
D

Spaced
1 1.00 1.00 1.00
D
≥ 2D
Ladder
supports,cleats etc. 2 0.97 0.95 0.93
(Note 3)
≥ 20 mm
3 0.96 0.94 0.90
NOTE 1 Value given are averages for the cable types and range of conductor sizes considered. The spread of values is generally less than 5 %

NOTE 2 Factors are given for single layers of cables (or trefoil groups) as shown in the table and do not apply when cables are installed in more
than one layer touching each other. Values for such installations may be significantly lower and should be determined by an appropriate method

NOTE 3 Values are given for vertical spacings between trays of 300 mm.For closer spacing, the factors should be reduced.

NOTE 4 Values are given for horizontal spacings between trays of 225 mm with trays mounted back to back. For closer spacing, the factors should be
reduced

NOTE 5 For circuits having more than one cable in parallel per phase, each three phase set of conductors should be considered as a circuit for the
purpose of this table

( I-2 )
PERMISSIBLE PULLING TENSION

Pulling equipment Permissible pulling tension (kg)


PULLING EYE 7 x (Number of core) x (Cross section area of conductor)
CABLE NET About 500 kg, but the maximum tension shall not be more than one of
conductor (same calculation as using PULLING EYE)

Reference data on Aluminium conductor


Pulling equipment Permissible pulling tension (kg)
PULLING EYE 4 x (Number of core) x (Cross section area of conductor)
CABLE NET About 500 kg, but the maximum tension shall not be more than one of
conductor (same calculation as using PULLING EYE)
Note) Cable net shall be covered more than 500 mm in length

MINIMUM BENDING RADIUS


D : Diameter of cable
Minimum bending radius
Type of cable Single core cable Multi core cable
Round/Compacted Sector conductor
Medium voltage cable 10D 12D 8D
3.6/6kV and above

Reference data on other types of POWER cables


Minimum bending radius
Type of cable Single core cable Multi core cable
Round/Compacted Sector conductor
Sheild cable 10D 12D 8D
Non sheild cable 8D 12D 6D
Triplex type cable - - 8D
Wire armored cable 10D 12D 10D
Tape armored cable 10D 12D 10D
Flat wire armoured cable 10D 12D 10D

Reference data on other types of INSTRUMENT cables


Type of cable Minimum bending radius
Multi core cable
Non sheild cable 6D
Sheild cable 6D Note) Sheild tape shall be AL mylar tape

(J)
PERMISSIBLE SIDE WALL PRESSURE

300kg/m is suggested as permissible side wall pressure to the cable during installation.

Side wall pressure (T1) can be calculated with below formula.


T kg
T
T1 =
r r

T = Pulling tension
r = Bending radius

CALCULATION OF CABLE PULLING TENSION DURING INSTRALLATION

The cable pulling tension (T2) during installation can be calculated with below formula.

1) Horizontal straight part : T2 = µ xW x L


T3 = T4 x e (µθ )

2) Horizontal curve part :

µ : Friction factor Friction factor


on pulley 0.2
underground 0.2 - 0.3
in pipe 0.5 - 0.7

W : Weight of cable (kg/m)


L : Length of cable with straight part (m)
θ : Angle of curve part (rad)
T2 : Pulling tension (kg)
T3 : Pulling tension before curve part (kg)
T4 : Pulling tension after curve part (kg)

VOLTAGE DROP
Vd = K x I x (Rac cos θ + X sin θ )

cos θ 2 + sin θ 2 = 1
I : Current of Conductor (A)
K : Coefficient
- Single phase system = 2
- Three phase system = 3
Rac : AC Conductor resistance (Ohm/km)
X : Reactance (Ohm/km)
(K)
NOTES
Head Office/Factory :
Jl. Gatot Subroto Km 7,8 Kel Pasir Jaya, Kec. Jati Uwung, Tangerang 15135-Indonesia
Phone : (62-21) 5922404, 5928066 (Hunting) Fax. : (62-21) 59301979,5922576, 5901469

© Copyright Sumi Indo Kabel 2007


G
D
C All rights reserved. This catalogue is the copyright work of PT. Sumi Indo Kabel Tbk. No part of this publication may be reproduced,
stored in a retrieval system, or transmitted, in any form or by means, electronic, mechanical, photocopying, recording or otherwise,
without prior permission of PT. Sumi Indo Kabel Tbk.
All information contained in this catalogue is believed to be accurate at the time issue. PT. Sumi Indo Kabel reserve the right to change
information or specification at any time in the light of technical developments or revisions.
Issue: 2 Date: 00/09/07