10 HEATER (H - 01)
Fungsi : Menaikkan temperatur feed (KD-01)
Gambar :
Gland Gland
Gland

Return
Band

Return Inner Pipe Annulus Tee


Head

Fluida panas : Steam


W = 239,40 kg/jam = 527,79 lb/jam
o o
T1 = 300 C = 572 F
o o
T2 = 300 C = 572 F
Fluida dingin : Crude Yodium Pentafluorida
W = 18136,67 kg/jam = 39984,10 lb/jam
o o
t1 = 50 C = 122,00 F
o o
t2 = 111,8 C = 233,29 F

Panas yang ditransfer, Qtr


Qtr = 80312,11 kkal/jam = 318702,54 Btu/jam

1). Menghitung selisih temperatur, LMTD

Fluida panas Temperatur Fluida dingin Selisih


572 Tinggi 233,29 338,71
572 Rendah 122,00 450,00
0 Selisih 111,29 111,29
241

Dt 2 - Dt 1
DLMTD =
æ Dt ö
ln çç 2 ÷÷
è Dt 1 ø
(450,00 - 338,71) oF 111,29 o
391,72 F
= = =
o 0,28
(450,00) F
ln [ (338,71) o
F
]

2). Temperatur rata-rata, Tavg dan t avg, oF


Tavg = 1
2 x (T1 + T2 )
æ ö
= 1 x ç
ç ## + ## ÷÷
è ø
o
= 572,00 F
t avg, = 1
2 x (t 1 + t 2 )
æ ö
= 1 x ç
ç ## + ## ÷÷
è ø
o
= 177,65 F

3). Trial harga UD


Asumsi harga UD = 74,0 Btu/hr.ft2.oF
Qtr
A =
UD x LMTD

318702,54
=
74,0 x 391,72
2
= 10,99 ft
Karena A < 200 ft2, maka direncanakan memilih alat penukar panas tipe Double

Pipe Heat Exchanger (DPHE) dengan spesifikasi (Kern, tabel 11, p.844)
ukuran pipa dalam dan pipa luar yang dipilih 3" x 2.5". Pemilihan ukuran pipa dianggap
benar jika hasil perhitungan nantinya diperoleh perbedaan tekanan pipa dalam dan luar
242

masing-masing kecil dari 10 psi


Mengingat pipa dalam yang digunakan berukuran 2.5 in, maka untuk harga luas area
pipa (a') dari tabel 11 Kern didapat :
2
a' = 0,753 ft /ft
A
Panjang pipa L =
a'
10,99 ft2
=
0,753 ft2/ft
= 14,60 ft

Dipilih alat HE = 2 buah hairpin dengan panjang3,80 ft


Panjang pipa total = 2 x 2 x 3,8
= 15,20 ft
Koreksi luas (luas permukaan sebenarnya) :
A= L x a'
= 15,20 ft x 0,753 ft2/ft
2
= 11,45 ft

Koreksi harga UD

Q
UD =
A . Dt

318702,54
UD =
11,45 x 391,72
= 2o
71,08 Btu/hr.ft . F

Karena UD mendekati harga UD asumsi, maka asumsi ukuran pipa dapat dipakai:

Sumber : (Kern tabel 11, p.844)


243

Annulus Inner Pipe


IPS = 3 in IPS = 2,5 in
ID = 3,068 in ID = 2,469 in

OD = 3,5 in OD = 2,88 in
SN = 40 SN = 40

a = 7,38 ft2/ft a = 0,753 ft2/ft

4). ANNULUS : FLUIDA PANAS, STEAM


(1). Flow area, aa
D2 = 3,07 in = 0,26 ft
D1 = 2,88 in = 0,24 ft

p (D 22 - D12 )
aa =
4
= 3.14 x ( 0,26 ft)2 - ( 0,24 ft)2 = 0,006 ft2
4
Equivalent diameter, De
(D 22 - D12 ) Sumber: (Kern. Ers. 6.3)
De = =
D1
= (0,26 ft)2 - ( 0,24 ft) 2
= 0,03 ft
0,24 ft
(2). Laju alir massa, Ga

W
Ga =
aa

527,79 lb/jam
=
2
0,01 ft
= 86581,69 lb/jam ft2
244

o
(3). Pada Tc = 572 F
µ = 0,02 cp = 0,05 lb/hr.ft

De x G a
R ea =
m

= 0,03 x 86581,69
0,05
= 57809,30
(4). jH pada Rea 57809,30 = 170 Sumber : (fig. 24 Kern, P. 834)
o
(5). Pada Tc = 572 F

Kapasitas panas steam (c) = 0,27 Btu/lb.oF Sumber : (fig 3, p 805, Kern )
2 o
Konduktivitas thermal (k) =0,028 Btu/hr.ft .( F/ft)
Sumber : (Tabel 5, Kern P. 802)
1

é k ù é c .m ù
3

(6). ho = jH . ê ú x ê k ú x f , harga Ф = 1
ë De û ë û

0,028 0.5
= 170 x [ ] x[[ 0,27 x 0,05
] x 1
0,03 ft 0,028

ho = 100,56 Btu/hr.ft2.oF

5). INNER PIPE : Crude Yodium Pentafluorida

(1). Flow Area, ap

p .D 2
ap =
4

D = 2,88 in = 0,24 ft
3,14 x 0,06
ap =
4
= 0,05 ft2
245

(2). Laju alir massa, Gp

W
GP =
ap

39984,10 lb/jam
=
0,05 ft2

= 884290,99 lb/jam ft2


o
(3). Pada Tc =177,65 F

µ = 0,39 cP = 0,94 lb/hr.ft

D x Gp
R ep =
m
= 0,24 x 884290,99
0,94
= 224588,97

(4). jH pada Rea 224588,97 = 290 Sumber : (fig. 24 Kern, P. 834)

o
177,647 F
(5). Pada Tc =
Kapasitas panas steam (c) = 1,68 Btu/lb.oF Sumber : (fig 3, p 805, Kern)

Konduktivitas thermal (k) = 1,97 Btu/hr.ft2.(oF/ft)


Sumber : (Tabel 5, Kern P. 802)
1

é k ù é c .m ù
3
(6). hi = jH . ê x ê x f , harga Ф = 1
ú ú
ë De û ë k û
0.5
1,97 1,68 x 0,94
= 290 x [ ] x[[ ]x 1
0,24 ft 1,97
2o
ho = 2136,9 Btu/hr.ft . F
246

ID
(7). h io = hi x
OD
OD = 2,47 in

ID = 2,88 in
2,88 in
hio = 2136,90 x
2,47 in
= 2492,61 Btu/hr.ft2.oF

6). Clean Overall Coefficient, Uc

h io x h o
UC =
h io + h o Sumber : (Pers. 6.7 Kern)

2492,61 x 100,56
=
2492,61 + 100,56
2o
= 96,66 Btu/hr.ft . F

7). Design Overall Coefficient, UD

1 1
= + Rd
UD UC Rd diasumsi 0,003
2o
1/UD = 0,013 Sehingga UD = 74,93 Btu/hr.ft . F

8). Required Surface Area

Q
A=
U D . Dt

318702,54
=
74,934 x 391,72
= 10,86 ft2

External surface /lin ft, a" = 0,75 ft2/ft Sumber : (Tabel 11 Kern)
247

Panjang pipa, A/a" = 14,42 ft

Dipakai hairpin yang panjangnya 3,80 ft


14,42
Maka jumlah hairpin =
3,8 x 2,0
= 1,90 (dibutuhkan 2 buah)
Koreksi panjang pipa = 2,0 x 2 x 4
= 15,20 ft
9). Actual surface Area:
A = 15,2 x 0,75
= 11,45 ft2

10). Actual Design Overall Coefficient, UD actual


Q
UD =
A . Dt
318702,54
=
11,45 x 391,72

= 71,084 Btu/hr.ft2.oF

11). Dirt Factor Coefficient, RD


UC - UD
RD =
UC x UD

96,66 - 71,08
=
96,66 x 71,08
= 0,004
248

12). Pressure Drop


ANNULUS : Fluida Panas, Steam
(1). De' = D2 - D1
De ' = 0,26 - 0,24
= 0,02 ft

D'e . G a
R 'ea =
m

0,02 x 86581,69
= = 27991,05
0,05
Untuk nilai Aliran turbulen NRe > 1.000 digunakan persamaan berikut:

0.264 Sumber : Pers. 3.47 b. Kern)


f = 0.0035 +
R '
ea
0.42

= 0,01

Densitas (ρ) = 9,3 kg/m3 = 0,58 lb/ft3

(2). DF = 4 . f . G a2 . L
2 . g . r2 . D'e
A

4 x 0,01 x 7496388356,52 x 15,2


=
8
2 x 4,18 x 10 x 0,34 x 0,02
3226823212,59
= = 731,57
4410806,00
(3). Ga
V =
3600 . r

86581,69
=
3600,0 x 0,58
249

86581,69
=
2089,15
= 41,44

V2
(4). F1 = jumlah hairpin x
2. gC

1717,56
= 2 x
2 x 32,20
F1 = 53,34

DPa =
DFa + FL  . r
144
( 731,57 + 53,34) x 0,580
(5). DPa =
144
DPa = 3,163 psi

Karena ∆pp < 10 psi, berarti hasil perhitungan pada batas yang diizinkan

INNER PIPE : Fluida dingin


'
(1). Rea = 224588,97
Untuk nilai Aliran turbulen Nre > 1.000 digunakan persamaan berikut:

0 .264 Sumber : (Pers. 3.47 b. Kern)


f = 0 .0035 +
R  '
ep
0 .42

f = 0,005
3 3
Densitas = 576,87 kg/m = 36,00 lb/ft
Maka:

(2). D F = 4 . f . G 2p . L
2. g . r2 . D
P
250

4 x 0,005 x 781970549778,65 x 15,200


=
8
2 x 4 x 10 x 1295,762 x 0,2400
2,37E+11
= = 0,913 ft
2,60E+11

DFP . r
D
D
V

(3). DPP =
D
P
F
FP
1
=
a
a
=
a
==
36=
ju

G
m
0
D

l
0
F
a
a
h
.
a
r
+
1
h
4
ai
4
F
L
rfin
 . r
x
2
V
.
2

g C

144
0,91 x 36,00 32,87
= =
144 144
= 0,23 psi

Karena ∆pp < 10 psi, berarti hasil perhitungan pada batas yang diizinkan
251

10 HEATER (H - 01)

IDENTIFIKASI
Nama Alat Heater
Kode Alat (H - 01)
Jumlah 1
Fungsi Menaikkan temperatur feed (KD-01)
DESAIN
Tipe DPHE (Double Pipe Heat Exchanger)
Jumlah Hairfin 2 buah
Panjang Hairpin 3,80 ft
Panjang Pipa Total 15,20 ft
Faktor Pengotor (Rd) 0,004
Bahan Konstruksi Cupro Alloys
ANNULUS INNER PIPE
IPS 3 in IPS 2,5 in
OD 3,5 in OD 2,88 in
ID 3,068 in ID 2,469 in
SN 40 SN 40
2 2
A 7,38 ft A 0,753 ft
2o 2o
ho 100,56 Btu/hr.ft . F hio 2492,61 Btu/hr.ft . F
Δp actual 3,16 psi Δp actual 0,23 psi
Δp Allowance 10,0 psi Δp Allowance 10,0 psi
OVER ALL
Actual Dirt Factor Coefficient , RD actual 0,004
Allowance Dirt Factor Coefficient , RD Allw. 0,050
Clean Overall Coefficient, Uc 96,7 Btu/hr.ft2.oF
Actual Design Overall Coefficient, UD actual 71,1 Btu/hr.ft2.oF
252

12

164

239,404

18136,7 80312,1

#######

[
253

12

DLMTD

Lihgt organik 100 ##


M 50 ##
H 6 60

G 5 50

Aquoes 200 ##
metanol 200 ##

74,93

Q
A=
U D . Dt

ilihan ukuran pipa dianggap


anan pipa dalam dan luar
254

12

ka untuk harga luas area

2,5

2
2,38
2,067
40
0,622
255

12

2,5 2 2,5 4 3
2,469 2,067 2,469 4,026 3,07
2,88 2,38 2,880 4,500 3,5
40 40,00 40,000 40,00 40
0,753 0,62 0,753 12,7 7,38

ft
256

12

0,27
0,028

k =
257

12

74,93436406
258

12

c =

k =

74,0
259

12
260

12

0,062422
8,42 g/cm3
0,52559
261

12

 

DPP
DPa =

593,374 1036
262

12

DPP
263

12
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287

Anda mungkin juga menyukai