Anda di halaman 1dari 4

INTRODUCTION

This worksheet determines the possibility of local buckle occuring in the riser at the clamp
locations using DNV OS F101, October 2010.
INPUTS
MATERIAL PROPERTIES
Nominal Diameter of Pipeline OD
nom
20in :=
Actual Outer Diameter of Pipeline OD
ac
20in :=
Wall Thickness t 0.812in :=
Pipe Material PL
mat
API 5L X42
API 5L X46
API 5L X52
API 5L X56
:=
Corrosion Allowance CA 0.118in :=
DESIGN CONDITIONS
Design Pressure P
des
2010psi :=
Design Temperature T
des
225 F :=
Product Description Product "FWS" :=
Density of sea water
sw
1025 kg m
3
:=
Water Depth WD 118.5ft :=
Case D
cond
1. Operating Case
2. Hydrotest Case
:=
AUTOPIPE INPUTS
M
F
139321lbf ft := Moment due to Functional Load
M
E
44427lbf ft := Moment due to Environmental Load
S
F
9299lbf := Axial load due to Functional Load
S
E
4806lbf := Axial load due to Environmental Load
DNV OS F101 INPUTS

F
1.1 := Load effect factor for Functional Load, Table 4-4 DNV OS F101

E
1.3 := Load effect factor for Environmental Load, Table 4-4 DNV OS F101

C
1.07 := Condition Load effect factor, Table 4-5 DNV OS F101

m
1.15 := SLS/ULS/ALS = 1.15, FLS = 1, tABLE 5.4 Material resistance
factor

sc
1.14 := Low = 1.04, Medium = 1.14, High = 1.26
f
y.temp
23MPa := Derating value due to temperature of the yield stress- Figure 2, the
derating value is considered for values above 50 deg C only for
Carbon steel pipes
f
u.temp
23MPa :=

u
0.96 := Material Strength factor - Table 5-6 DNV OS F101
DERIVED DATA
SMYS
SMTS
Wall thickness to be used is
S
smys
42000 psi =
U
smts
60200 psi =
t 0.694 in =
f
y
S
smys
f
y.temp

( )

u
3.712 10
4
psi = :=
f
u
U
smts
f
u.temp

( )

u
5.459 10
4
psi = :=
P
hyd
g WD
sw
52.657 psi = := Pressure as a result of the water depth
f
cb
min f
y
f
u
1.15
,
|

\
|
|

3.712 10
4
psi = :=
P
bu
2 t CA ( )
OD
ac
t CA ( )

(
(

f
cb

2
3
2.542 10
3
psi = :=
CALCULATIONS
The Design Moment is given by
M
Sd
M
F

F

C

( )
M
E

E

( )
+ :=
Inteference and Accidental loads are assumed to be Zero
The plastic capacity for a pipe is given as
M
p
f
y
OD
ac
t
( )
2
t :=
The normalised moment is given as
M
Sdn
M
Sd
M
p
0.277 = :=
The design Effective axial force is given by
S
Sd
S
F

F

C

( )
S
E

E

( )
+ := Inteference and Accidental loads are assumed to be Zero
The plastic capacity of the pipe is given as
S
p
f
y
OD
ac
t
( )
t :=
The normalised axial force is given as
S
Sdn
S
Sd
S
p
0.011 = :=
Factor used in combined loading strain is given as
0.5
OD
ac
t
|

\
|
|

15 < if
60
OD
ac
t
|

\
|
|

90
15
OD
ac
t
|

\
|
|

60 if
0
OD
ac
t
|

\
|
|

60 > if
:=
0.346 =
Effect of the D/t ratio is given as

p
1 ( )
P
des
P
hyd

P
bu
|

\
|
|

2
3
|

\
|
|

< if
1 3 1
P
des
P
hyd

P
bu

\
|
|

(
(

P
des
P
hyd

P
bu
|

\
|
|

2
3
if
:=

p
0.761 =
Flow stress parameter is given as

c
1 ( )
f
u
f
y
|

\
|
|

+ 1.163 = :=
LOAD CONTROLLED CONDITION
Pipe members subjected to bending moments, effective axial force and internal overpressure
shal be designed to satisfy the condition that the result of the equaltion must be less than 1
LB
pos

m

sc

M
Sdn

\
|
|


m

sc
S
Sdn

c
|

\
|
|

2
+

(
(
(

p
P
des
P
hyd

c
P
bu

\
|
|

(
(

2
+ 0.351 = :=
is "Not Likely" LB
pos
1 < if
"Likely" LB
pos
1 if
:=
The possibility of buckling at the location is "Not Likely" =