Anda di halaman 1dari 51

Which SCSI ID has the highest priority on a SCSI bus?

A.

237339316 2

B. C. D.

7 8 15

Which drive type is best for holding large amounts of reference data?
A.

237339317 2

ATA

B. C. D.

SCSI SATA Fibre Channel

Which statement is correct concerning LUN ownership in an active/active controller configuration?


A.

237339318 2

All LUNs are owned by the same controller.

B. C. D.

A LUN is owned by one controller at a time. Ownership of all LUNs is shared between both controllers. The LUN is owned by the controller to which the I/O is directed.

Which actions are recommended to avoid functional problems when configuring or installing a SCSI bus? (Select two.)
A.

237339319 3

Terminate every SCSI device.

B. C. D. E.

Use passive termination for LVD SCSI. Use the same SCSI ID for identical device types. Visually inspect the connectors for damaged pins.

Fasten the connectors with the screws provided on the connectors. Two drives in one array fail at the same time, where RAID 5 and ADG are in use. What happens to the logical drives?
A.

237339320 2

RAID 5 and ADG become unavailable.

B. C. D.

RAID 5 and ADG become performance reduced. RAID 5 and ADG stay available without any restriction.

RAID 5 becomes unavailable and ADG becomes performance reduced. The embedded MSA1000 SAN switch 2/8 allows full integration with which option?
A.

237339321 2

Hubs

B. C. D.

C-Series (Cisco) switches M-Series (McData) switches B-Series (Brocade) switches

What is the operational configuration limit for Secure Path 4.0c for Windows in an MSA storage environment? (Select two.)
A.

237339322 3

a maximum of 20 hosts per set of shared storage systems (per profile) a maximum of 128 hosts per set of shared storage systems (per profile) a maximum of 256 storage systems shared by a set of hosts

B. C.

(per profile)
D. E.

a maximum of 32 LUNS per target with a maximum of two paths per LUN

a maximum of 128 LUNS per target with a maximum of two paths per LUN Which rule applies for spare drive configuration with the Storage Management Utility for the MSA1510i?
A.

237339323 2

A spare disk must be the same speed as the other drives in the array. A spare disk can be mixed with SCSI and SATA drives in the same array. A spare disk must be the same size (or smaller) as the other drives in the array. A spare disk must be the same type (SCSI or SATA) as the other drives in the array.

B. C. D.

What must be replaced to upgrade the StorageWorks 4200/4300 enclosure to an MSA30? (Select two.)
A.

237339324 3

backplane

B. C. D. E.

I/O module SCSI cable power supply environmental monitoring unit

Which statement is correct about a second controller module in an MSA20?


A.

237339325 2

It is not supported.

B.

It is required for fault tolerance.

C. D.

It is used for better connectivity.

It is required for simultaneous support of SATA and SCSI drives. How many MSA30 drive shelves does a fully configured MSA1500cs use?
A.

237339326 2

B. C. D.

3 4 8

What is the Storage Management Utility?


A.

237339327 2

a replacement for the Array Configuration Utility

B. C. D.

an alternate management tool for MSA1xxx systems a dedicated management tool for MSA1510i systems a replacement for the MSA1510i Command Line Interface

What does an MSA1500cs provide the ability to use?


A.

237339328 2

disk drives from an HP-XP

B. C. D.

disk drives from an EVA3000 a tiered storage approach using SATA and SCSI SATA and SCSI disk drives in the same drive shelf

What is the role of an MSA1510i controller in an iSCSI environment?


A.

237339329

agent

B. C. D.

target server initiator

In which situation is multipath configuration of MSA1500cs systems supported?


A.

237339330 2

in cluster environments

B. C. D.

if multipath software is installed on all hosts with multipath access to the MSA1500cs if multipath software is installed on the host where the Array Configuration Utility is installed multipath configuration

What must you do to update the second controller through ROM cloning?
A.

237339331 2

Activate ROM cloning in the ACU.

B. C. D.

Activate ROM cloning in MSA Flash. Insert the second controller while the MSA is powered on. Insert the second controller while the MSA is powered off.

To provide controller redundancy, which statement is correct?


A.

237339332 2

Redundant connections to the drive enclosures must also be provided. Only two controllers are required which can share one Fibre Channel I/O module. Each controller requires its own Fibre Channel I/O module and a separate path to the host bus adapters.

B. C.

Each controller requires its own Fibre Channel I/O module and the host system needs only one host bus adapter. When are you prompted for user input with the MSA controller front panel?
A.

D.

237339333 2

once the host link breaks

B. C. D.

at any time during operation during system power-on testing when you start a remote management session

Which statement about hot-pluggable parts of an MSA1500cs is correct?


A.

237339334 2

All parts of an MSA1500cs are hot-pluggable.

B. C. D.

By replacing hot-pluggable parts, the system guarantees the data integrity. Before replacing a hot-pluggable part, set the system in maintenance mode. Before replacing hot-pluggable parts, ensure that all steps have been taken to prevent data loss.

How can the Command Line Interface of an MSA1000 be accessed through the serial port?
A.

237339335 2

Establish a network connection and use telnet.

B. C. D.

Establish a host connection and use hyperterminal. Establish a serial connection and run CommandView MSA. Establish a Fibre Channel connection and run sssu.exe (Storage System Scripting Utility).

Which software type represents the Storage Management Utility (SMU) and how is it installed?
A.

237339336 2

SMU is a modular component of the MSA controller firmware and comes factory installed. SMU is a component of HP Systems Insight Manager (HP SIM) and is installed along with HP SIM. SMU is a self-propagating client and can be installed on any system with a TCP/IP connection to the MSA.

B. C. D.

SMU is an agent and must be installed individually on each host with a Fibre Channel connection to the MSA. Which statement is correct regarding the cache module configuration of redundant MSA1000 controllers?
A.

237339337 2

The memory size of all cache modules must be the same.

B. C. D.

If the cache sizes are different, only read caching is possible. If the cache sizes are different, mirrored cache cannot be enabled. The total cache memory size of each controller must be the same, regardless of the size of a single cache module

What is the electrical specification of the Ultra320 port of the SCSI I/O module?
A.

237339339 2

SE (single ended)

B. C. D.

LVD/SE autosense LVD (low-voltage differential) HVD (high-voltage differential)

What must you consider when upgrading a dual-controller MSA1000 from active/passive to an active/active mode?
A.

237339340 2

The cache must be disabled during the upgrade.

B. C.

Path failover during the rolling upgrade must be prevented. Backward migration to active/passive mode will cause loss of the configuration.

D.

A single controller must be manually isolated by moving the LUNs to the other controller

A customer wants to introduce an MSA1000 into an existing SAN with B-Series (Brocade) switches. What connects the MSA1000 to the SAN?
A.

237339341 2

MSA Hub 2/3

B. C. D.

Gigabit Ethernet MSA Fabric Switch 6 MSA Fabric Switch 2/8

What is used by both the MSA1500cs and MSA20?


A.

237339342 2

fan modules

B. C. D.

SCSI I/O module SATA I/O module Fibre Channel I/O module

Which methods can be used to access the Command Line Interface of an MSA1510i? (Select three.)
A.

237339343 3

SNMP

B. C. D. E.

HTTP connection Telnet connection serial line connection secure shell connection

F.

remote terminal session

Which rule applies when you install a second cache module on an MSA1000 controller?
A.

237339344 2

The size of the cache modules must be the same.

B. C. D.

The smaller module determines the total write cache size. The larger module is limited to the size of the smaller module.

The larger module must be installed in the primary array accelerator slot. In which SAN environment can you install an MSA1000 with an embedded SAN switch 2/8?
A.

237339345 2

a B-Series switch environment

B. C. D.

any loop switch SAN environment any Fibre Channel SAN environment an MSA SAN switch 2/16 environment

Which management software is required to set up and manage an MSA1500cs?


A.

237339346 2

Array Configuration Utility

B. C. D.

Storage Management Utility HP Storage Essentials MSA HP Systems Insight Manager

Which MSA1000 component firmware cannot be updated with the MSA Flash utility?
A.

237339347

MSA1000 EMU

B. C. D.

MSA1000 controller MSA SAN Switch 6 MSA SAN Switch 2/8

An MSA30 power supply fails. What are the appropriate steps to take?
A.

237339348 2

Remove it, check the part number and order a replacement.

B. C. D.

Check the part number, leave it in place and order a replacement. Swap the position with the working power supply to verify it has failed.

Remove the power cord and wait until the next scheduled maintenance. You are using the Command Line Interface on a customer's MSA1500cs to perform a firmware upgrade. Which command determines the firmware of the controller?
A.

237339349 2

show firmware

B. C. D.

show globals all show active_status show this_controller

What is the default management port of the MSA1510i iSCSI module?


A.

237339350 2

MA0

B.

MA1

C. D.

MB0yut MB1

Which free-of-charge software must be installed in a redundant MSA1500 active/active environment for multipathing support on a Windows 2003 server?
A.

237339351 2

AutoPath

B. C. D. E.

Secure Path 4.0c MPIO Basic DSM Secure Path MSA MPIO Full Featured DSM

What is the purpose of the four push buttons on the MSA1000 controller? (Select two.)
A.

237339352 3

Enter the WWN.

B. C. D. E.

Reset the controller. Respond to prompts. Scroll to an older message. Single step the power on selftest if controller is in debug mode.

What does the flashing green indicator next to the power switch of an MSA1500cs indicate (2 on the exhibit)?
A.

237339353 2

Self test is running.

B. C.

Operation is normal. Only one power supply is working.

D.

Host is accessing the storage system.

You must update an MSA1510i firmware at a customer site. Which command determines the current firmware version of the controller?
A.

237339354 2

show firmware

B. C. D.

show globals fw show iscsi_cont show tech_support

How can you identify the primary or redundant controller in an active-passive MSA1500cs controller configuration?
A.

237339355 3

Use the ACU locate function.

B. C. D.

Use the CLI locate command. Refer to messages on the LCD display.

Check status of the 1G or 2G LED on the Fibre Channel I/O module. How many logical names has an Ethernet iSCSI module port by default?
A.

237339356 2

B. C. D.

2 3 4

Which operation clones the firmware during startup after a redundant MSA controller and a Fibre Channel I/O module have been installed?

237339357 2

A.

pressing the > button on the controller at startup

B. C. D.

pressing the < button on the controller at startup system ROMpaq initiated firmware cloning after startup checking the clone firmware box in ACU before startup

After a power outage of the whole environment, the MSA1000 controller displays the error message shown on the exhibit. What is the most likely problem?
A.

237339358 2

Fibre Channel I/O module failed.

B. C. D.

MPIO initiated a failover during boot. The B-Series switch is still running the POST. Zone configuration was lost during the power failure.

After powering on an MSA1500cs SAN solution, not all servers can access the assigned LUNs from the MSA. What has happened?
A.

237339359 2

Servers were started up prior to the MSA startup.

B. C. D.

MSA LUNs are set to not presented after startup. The Fibre Channel HBAs are set to an incompatible speed. The at once startup value of the MSA has been exceeded.

While entering redundant mode an MSA1510i reports REDUNDANCY FAILED FIRMWARE LOOKUP. What will be a result?
A.

237339361 2

Redundancy will be disabled.

B. C. D.

The firmware must be updated. Battery-backed cache memory data will be flushed to the drives.

Cache data will be erased and the operation continues normally. You are powering on an MSA1500cs with two controllers. What happens if one corrupted firmware ROM is detected?
A.

237339362 2

The affected controller automatically becomes the standby controller. The startup process stops and waits for input from the Operator Control Panel. The valid image from the other ROM is copied on top of the corrupted image to correct it.

B. C.

D.

A valid image from the other controller is copied on top of the corrupted image to correct it.

In a fully operational MSA1000 with two redundant controllers, one controller fails. The replacement controller has a newer firmware version. What happens when the MSA1000 is powered off while the new controller is inserted and then powered on?
A.

237339364 2

The old firmware remains operational and will also be used on the new controller. The MSA1000 compares the firmware on both controllers and uses the most recent version. The MSA1000 recognizes that there are different firmware versions, displays an error message, and stops operation.

B. C. D.

The old firmware remains operational. The replacement controller with the new firmware must be downgraded manually. How must you configure an MSA controller so that a hard disk failure will not affect a second logical drive?
A.

237339365 2

Use Selective Storage Presentation.

B. C. D.

Configure only one logical drive per array. Set the ownership of the logical drives to different controllers.

Use RAID 6 (ADG) for the array in which you create the logical drives. Where is the slot diagram label located in an MSA1500cs solution?
A.

237339366 2

on the rear of the MSA1500cs

B. C. D.

in the Storage Management Utility on the inside of the top cover of the MSA on the rear of the first attached enclosure

You have a configuration with three virtual disks configured in one array. One virtual disk is RAID 0, one is RAID 5 and one is ADG. Identify the correct statements if one hard drive has failed and you remove a wrong (running) drive from this array. (Select two.)
A.

237339367 3

ADG is still online.

B. C. D. E.

RAID 5 is still online. RAID 5 has data loss after first drive failure. ADG has data loss when you remove the wrong drive. RAID 5 has data loss when you remove the wrong drive.

Where can you generate and save a diagnostic report for the MSA1510i?
A.

237339368 2

under the diagnostics tab of HP Systems Insight Manager

B.

from the diagnostics tab in Storage Management Utility

C. D.

under the management tab of Array Configuration Utility from the Array Diagnostic Utility management tab

Which utility gives you the most information to diagnose potential MSA1000 controller problems?
A.

237339369 2

ADU

B. C. D.

ACU SMU HP SIM

While scrolling error messages using the operator control panel (OCP) of an MSA1500cs, a new error occurs. Which statement is correct?
A.

237339370 2

LED 18 illuminates, indicating a new error condition.

B. C. D.

The LINK LED flashes, indicating a new error condition. Push right and left push button simultaneously to display the error.

The new error is displayed at the OCP regardless of the scrolled position. When must you power down an MSA1000 system for repair?
A.

237339371 2

EMU failure

B. C. D.

controller failure dual disk failure power supply failure

Where can you obtain the IP address of the MA0 port to enable configuration of the MSA1510i iSCSI module through the Storage Management Utility?
A.

237339372 2

Use ipconfig /all from any host connected to the MSA1510i.

B. C. D.

From HP Systems Insight Manager, scan for available IP addresses. Use telnet to use the Command Line Interface using the <discover IP> command.

Press the arrow buttons on the Operator Control Panel to scroll through the messages until 603 Port MA0 IP <address> displays. What is a recommended guideline for building an array with the Array Configuration Utility?
A.

237339373 2

Use partitioned physical disks for better disk performance.

B. C. D.

Use physical disks with different storage capacities for better disk efficiency. Use physical drives that reside on different buses for better system efficiency.

Use physical drives that reside on different buses for better system performance. When you start the Array Configuration Utility installed from the MSA1500cs support CD, what is discovered?
A.

237339374 2

MSA1000s and MSA1500s in the connected LAN

B. C. D.

MSA1000s and MSA1500s in the connected SAN MSA1500s, but no MSA1000s in the connected LAN MSA1500s, but no MSA1000s in the connected SAN

Which software is part of the MSA1510i array controller firmware and is accessed by a remote server?

237339375 2

A.

MSA Configuration Utility

B. C. D.

Array Configuration Utility Storage Management Utility StorageWorks Configuration Utility

When do configuration changes in the Array Configuration Utility (ACU) take effect?
A.

237339376 2

immediately

B. C. D.

after restarting the controllers after pressing the Save button after refreshing the ACU display

Which management port information is required before accessing an MSA1510i using the Storage Management Utility? (Select two.)
A.

237339377 3

IP address

B. C. D. E.

MAC address World Wide Name username and password fully qualified domain name

How is unused space obtained when extending a logical drive?


A.

237339378 2

by expanding an array or deleting another logical drive in the same SAN by expanding an array or deleting another logical drive in the

B.

same array
C. D.

by expanding an array or deleting another logical drive in the same controller

by expanding an array or deleting another logical drive in the same Array Configuration Utility session Which statements about an array is correct? Select TWO.
A.

237339379 3

It can have only one spare.

B. C. D. E.

It can have several spares. It can only use a spare exclusively. It can share spares with several arrays. It can use a spare for logical drive extension.

Using the Command Line Interface of an MSA1500cs, what does the command option Profile define when adding a connection?
A.

237339380 2

operating system

B. C. D.

RAID level of the LUN speed of the connection Fibre Channel adapter model number

What is a characteristic of the read-ahead caching mechanism?


A.

238304122 2

Every I/O goes directly to the respective disk.

B. C.

The data read from the disks stays in cache until it reaches a threshold. Every I/O goes into the RAID controller cache and in a background operation to the respective disk.

The RAID controller reads more data than requested from the disks, predicting the next read from the host that needs this additional data. Which Fibre Channel topology is used for host connection with a single MSA Hub 2/3?
A.

D.

238304121 2

fabric

B. C. D.

multipath dual loop arbitrated loop

What are two functions of RAID level 5? (Select two.)


A.

238304124 3

uses only one physical disk in the array for parity

B. C. D. E.

distributes the parity onto every available disk in the array distributes two different parities onto every available disk in the array usually has the highest cost per GB of usable space because it duplicates the data

has moderate costs per GB because it uses the capacity of one disk for parity per array Which statement is true regarding a dual-path configuration with a single controller?
A.

238304125 2

It is not supported.

B. C. D.

It requires Secure Path software. It is supported without Secure Path software. It requires the Redundancy Manager software

How can an MSA1500cs be configured?

238304128 2

A.

using two 3-port mini hubs

B. C. D.

with two 8-port switch modules with two Fibre Channel I/O modules using two single port SCSI modules

Which statement about MSA-supported multipath software is correct?


A.

238304129 2

The QLogic Multipath Driver is required for Linux operating systems. HP Secure Path is required for all MSA-supported operating systems. The QLogic Multipath Driver cannot be used for Linux operating systems.

B. C. D.

HP Secure Path and the Microsoft Multipath I/O driver (MPIO) can be used for all MSA-supported operating systems. How can you extend the storage capacity of a logical drive using the Array Configuration Utility? (Select two.)
A.

238304130 3

Add a hot spare to the array.

B. C. D. E.

Add a new disk to the logical drive. Add unused space from any array to the logical drive. Add a new disk to the array where the logical drive resides.

Add unused space from the array where the logical drive resides. Which modules of an MSA1500cs system have cache memory with backup batteries? (Select two.)
A.

238304132 3

MSA controller modules

B. C. D. E.

MSA20 SCSI I/O module MSA1500cs SCSI I/O module MSA30 environmental monitoring unit MSA1500cs Fibre Channel I/O module

Which tools do you use to update firmware on the MSA1000? (Select two.)
A.

238304135 3

SmartStart V7.x

B. C. D. E.

MSA Flash utility Insight Manager 7 Command Line Interface Array Configuration Utility

Which multipathing software is supported for an MSA1510i system in a Windows environment?


A.

238304136 2

Microsoft MPIO

B. C. D.

Network Teaming SecurePath for iSCSI QLogic failover driver

Where does the Storage Management Utility reside?


A.

238304139 2

on the storage management host

B. C.

on the controller ROM of the MSA system on a host with a TCP/IP connection to the MSA

D.

on a host with a Fibre Channel connection to the MSA

You have a redundant MSA1000 configuration with host ABC accessing logical drives on the MSA1000. You install a second host XYZ to access logical drives. Both hosts run Windows 2003. Referring to the exhibit, why are you unable to access the MSA1000 from Host XYZ? (Select two.)
A.

238304140 3

Zoning is enabled on the switches, but not configured for host XYZ. Zoning is enabled on the switches, but not configured for host ABC. Selective Storage Presentation is enabled, but not configured for host XYZ. Selective Storage Presentation is disabled and not configured for host XYZ.

B. C. D. E.

Secure Path is installed on host XYZ, which prevents the host from accessing any logical drive. Which cable is supported for connecting an MSA20 to an MSA1500?
A.

238304141 2

4 meter 7-pin SATA

B. C. D.

low-voltage differential SCSI ultra wide single-ended SCSI 2 meter multimode fiber optic

Which slots of the MSA1500cs can be used for additional SCSI I/O modules? (Select two.)
A.

238304143 3

B.

C. D. E.

3 5 6

What can the two ports on a single SCSI I/O module of an MSA1500cs be used to connect? (Select two.)
A.

238304147 3

two MSA20

B. C. D. E.

two MSA30 one MSA20 and one MSA30 one MSA30 with a single bus I/O module one MSA30 with a dual bus I/O module through a Y-cable

Which tools can be used to update the MSA1000 controller firmware? (Select two.)
A.

238304148

MSA Flash Utility

B. C. D. E. F.

ADU (Array Diagnostic Utility) SIM (System Insight Manager) ACU (Array Configuration Utility) SMU (Storage Management Utility) MSA CLI (Command Line Interface)

What is the correct default username and password when logging in to an MSA1510i controller?
A.

238304149 2

root, root

B. C. D.

user, admin root, password Administrator, Administrator

For the MSA1500cs, what is supported in a multipath environment?


A.

238304152 2

SCSI or SATA drive enclosures

B. C. D.

dual paths to the drive enclosures SCSI, but not SATA, drive enclosures SATA drive enclosures configured as Advanced Data Guarding fault-tolerant logical units

What must you do to power off an MSA1500cs system?


A.

238304154

Wait until all rebuild operations are finished.

B. C. D.

Make sure no operating system is using any unit on the MSA1500cs system. Power off the storage enclosure before you power off the MSA1500cs enclosure. Use the shutdown command of the Command Line Interface or the shutdown button of the Array Configuration Utility before you power off the system

A customer reports a failure with the SCSI I/O module on SCSI bus 1. Click the affected component.

In a redundant MSA1000 configuration, what is the recommended action if a controller fails during an expansion process?
A.

238304157 2

Replace the failed controller online.

B. C. D.

Power off the MSA1000 and replace the failed controller. Remove the failed controller and install the old cache module in the replacement controller. Push the right arrow push button on the front panel to fail over

the controller and replace the failed controller. You should record the IEEE world wide ID of the Fibre Channel adapter before you mount it in the server. Why?
A.

238304159 2

It is needed for later setup of DtS.

B. C. D.

It is needed for later setup of SSP. It is needed for later setup of the LAN. It is needed for later setup of the SAN.

Which LED on the MSA1000 controller indicates an error message was sent to the controller display?
A.

238304160 2

B. C. D.

15 16 17

Cache batteries have been replaced and recharged. What must you do next to ensure full cache operation?
A.

238304161 2

Nothing. The cache will be re-enabled automatically.

B. C. D.

Cache must be re-enabled manually through the Command Line Interface. Cache must be re-enabled manually through the Storage Management Utility.

Re-enable read cache through Command Line Interface and then re-enable write cache through the Storage Management Utility. You replaced a Qlogic Dual Channel Fibre Channel HBA in a server connected to an MSA1500cs solution and must now update the HBA driver. Which sources can be used to obtain an HP supported, MSA-compatible driver for this HBA? (Select two.)
A.

238304162 3

Qlogic web site

B.

MSA Support Pack

C. D. E.

IT Resource Center MSA1500cs web site MSA1500cs Support Software CD

What are indicators of a temperature problem within the MSA1000 enclosure? (Select two.)
A.

238304163 3

The internal alarm activates.

B. C. D. E.

The integrated EMU LED is illuminated. The enclosure status indicators are flashing. An error message is displayed in the front panel. The enclosure status indicator fault LED is illuminated.

You reboot an MSA1500cs. The controllers fail to discover one or more of the disks that had been discovered previously. What is the corrective action?
A.

238304164 2

Replace the disk enclosure and ensure the firmware is compatible. Reboot the hosts and install the latest version of multipathing software. Reinstall the controller firmware as the previous version may be corrupt. Reboot the disk enclosures. Wait 1 minute before powering on the controller enclosure to allow correct initialization.

B. C. D.

Which free-of-charge software must be installed in a redundant MSA1500 active/passive environment for multipathing support on a Windows 2003 server?
A.

238304166 2

AutoPath

B. C. D. E.

Secure Path 4.0c MPIO Basic DSM Secure Path MSA MPIO Full Featured DSM

The status LED of an MSA30 Environmental Monitoring Unit (EMU) is flashing (once per second). What does this indicate?
A.

238304167 2

One power supply failed.

B. C. D.

The EMU is operating normally. There is an internal EMU problem. A single-ended disk device is installed

How many logical management ports on an MSA1510i can carry management traffic at the same time?
A.

238304173 2

B. C. D.

2 3 4

You are replacing a defective power supply in a redundant MSA1000 configuration. Which statement is correct?
A.

238304174 2

Power off the MSA1000 during replacement to reduce the risk of personal injury. Replace both power supplies at the same time because they contain the cache battery assembly.

B.

C.

Remove the power supply. Note the part number of the unit and order the replacement part. Install the replacement part when it arrives. Removing a power supply significantly changes the airflow in the cabinet. The remaining power supply will shut down the array after 5 minutes.
Arrange the steps to power on an MSA1500 solution in the correct sequence by dragging and dropping the boxes

D.

You are accessing an MSA1510i using the Command Line Interface over the LAN. Which connectivity type is recommended to maintain a high level of data security?
A.

238304182 2

SSH

B. C. D.

telnet SNMP hyperterm

What must be established to properly isolate a storage system? (Select two.)

A. B. C. D. E.

SSP on the switches zoning on the switches ACLs on the MSA controller zoning on the MSA controller VSANs on the MSA controller

You are managing multiple MSAs in an Array Configuration Utility session. What is the status of SSP?
A. B. C. D.

disabled by default for all MSAs and can be enabled per single MSA enabled by default for all MSAs and can be disabled per single MSA disabled by default for all MSAs and can be enabled for all MSAs together enabled by default for all MSAs and can be disabled for all MSAs together

What must you do to verify the currently installed firmware version of the MSA controller?
A. B. C. D.

Read the Status Panel. Scroll up the LCD messages of the MSA Operator Control Panel. Read the default LCD message of the MSA Operator Control Panel. Translate the two lines of eight LEDs on the controller as a 16-bit number.

A newly installed MSA1510i reports an error with the iSCSI module for controller A, physical port 1. Click the affected component.
Answer: 1

A new MSA controller indicates a temporarily disabled array accelerator during power on. What typically happens to the array accelerator?
A. B. C. D.

It will fail. It must be manually re-enabled. It will be automatically re-enabled. It must be inserted into the other DIMM slot.

A customer reports a failure in SATA box 8. Click the associated SCSI I/O module.
Answer 4

What does migrating a logical drive enable you to change? (Select two.)
A. B. C. D. E.

stripe size RAID level hosting array MSA subsystem controller in the same MSA

Which slot of the MSA1500cs is used for the second Fibre Channel I/O module?

A B C D

1 3 5 6

Which modules of an MSA1500cs system have cache memory with backup batteries? (Select two.)
A.

238309676 3

MSA controller modules

B. C. D. E.

MSA20 SCSI I/O module MSA1500cs SCSI I/O module MSA30 environmental monitoring unit MSA1500cs Fibre Channel I/O module

A customer has an MSA1500cs with 20 SATA and 40 SCSI disks. What is the required configuration?
A.

238309684 2

1 x MSA20 plus 4 x MSA30

B. C. D.

2 x MSA20 plus 2 x MSA30 2 x MSA20 plus 3 x MSA30 3 x MSA20 plus 2 x MSA30

A customer has an MSA1500cs with 20 SATA and 40 SCSI disks. What is the required configuration?
A.

238309684 2

1 x MSA20 plus 4 x MSA30

B. C. D.

2 x MSA20 plus 2 x MSA30 2 x MSA20 plus 3 x MSA30 3 x MSA20 plus 2 x MSA30

Using the MSA1000 Software Support CD, which installation options do you have? (Select two.)
A.

238309688 3

ACU-XE

B. C. D. E.

Secure Path new firmware MSA Flash utility Windows drivers

You have a redundant MSA1000 configuration with host ABC accessing logical drives on the MSA1000. You install a second host XYZ to access logical drives. Both hosts run Windows 2003.

Referring to the exhibit, why are you unable to access the MSA1000 from Host XYZ? (Select two.)
A.

238309693 3

Zoning is enabled on the switches, but not configured for host XYZ. Zoning is enabled on the switches, but not configured for host ABC. Selective Storage Presentation is enabled, but not configured for host XYZ. Selective Storage Presentation is disabled and not configured for host XYZ.

B. C. D. E.

Secure Path is installed on host XYZ, which prevents the host from accessing any logical drive. What is also required when installing a redundant MSA1000 controller?
A.

238309702 2

a second embedded switch

B. C. D.

correct zoning on the switch a Fibre Channel I/O module connected to an external switch

a Fibre Channel I/O module, externally connected to the embedded switch What are the different types of messages on the MSA1500cs controller display? (Select three.)
A.

238309720 3

fatal

B. C. D. E.

error locate warning user input

F.

informational

A RAID 5 array of SATA drives from an MSA20, connected to an MSA1500 was removed and mistakenly replaced in different slots in the MSA20. What happens at power on?
A.

238309725 2

The drives are not seen even after a rescan, as they already contain metadata. The controller recognizes that the drives have changed slots and the RAID 5 is recognized and available. The drives are recognized and available only after issuing the CLI command set raid 5 array enable. The RAID 5 array is lost and the drives are recognized as new drives and are available for configuration in an array

B. C. D.

To set up SSP, what do you configure?


A. B. C. D.

adapter ID and the connection name location to local and the status to online connection name and select a host mode adapter ID and change the status to online Answer: C

1.Click the Exhibit button. Which LED on the MSA1000 controller indicates a failure on a configured hard disk? A.LED 9 B.LED 15 C.LED 16 D.LED 17 Correct:B 2.The MSA1000 controller display module can hold up to 100 messages. Once the maximum is reached, the older messages will be ____. A.copied to the connected host using ACU-XE B.copied to the connected host using the serial line C.deleted D.copied to the connected metadata part of the disks Correct:C 3.The customer has a single controller MSA1000 configuration. What is the recommended action to replace the failed controller? A.Power down the MSA1000. Remove the failed controller and install the old cache module in the replacement controller.

B.Push the right arrow push button on the front panel to clear the cache of the controller and replace the failed controller. C.Replace the failed controller online, with a new cache installed. D.Push the left arrow push button on the front panel to clear the cache of the controller and replace the failed controller. Correct:A 4.What is the recommended action to take when a controller fails in a redundant MSA1000 configuration? A.Power off the MSA1000 and replace the failed controller. B.Replace the failed controller online. C.Push the right arrow push button on the front panel to failover the controller and replace the failed controller. D.Modify the zoning so that the MSA1000 is not accessible during the online replacement of the failed controller. Correct:B
The safer , easier way to help you pass any IT exams. 3/5

5.Click the Exhibit button. The EMU in a MSA1000 has detected a temperature problem. Which LED of the enclosure status indicators reports the problem and how does the LED display the error condition? A.LED 1 is off. B.LED 2 is amber. C.LED 3 is off. D.LED 3 is amber. Correct:D 6.Click the Exhibit button. Which LED on the MSA1000 controller indicates an error message was sent to the controller display? A.LED 9 B.LED 15 C.LED 16 D.LED 17 Correct:D 7.You are assigning DISK109 as a spare drive to array B containing logical drives 2 and 3. What is the correct CLI (command line interface) command? A.ADD SPARE UNIT=2 DISK109
The safer , easier way to help you pass any IT exams. 4/5

B.ADD SPARE ARRAY B DISK109 C.SET SPARE ARRAY B DISK109 D.SET SPARE UNIT 3 DISK109 Correct:A 8.Click the Exhibit button. On an MSA1000 disk, LEDs 1 and 2 are OFF, and LED 3 is ON. What is the possible cause for the status and which action should you take?. A.The drive is part of the selection of the array configuration utility. Do not remove this drive without verifying the configuration. B.The array is rebuilding. Do not remove this drive without verifying the configuration. C.The array is performing an online expansion. Do not remove this drive without verifying the

configuration. D.The drive failed and has been taken offline. You can remove the drive. Correct:D 9.You are replacing a defective power supply in a redundant MSA1000 configuration. Which statement is correct? A.Remove the power supply. Note the part number of the unit and order the replacement part. Install the replacement part when it arrives. B.Power off the MSA1000 during replacement to reduce the risk of personal injury. C.Replace both power supplies at the same time because they contain the cache battery assembly. D.Removing a power supply significantly changes the airflow in the cabinet. The remaining power supply will shutdown the array after 5 minutes. Correct:D 10.The customer has a redundant MSA1000 configuration. Identify the correct statement about replacing an array accelerator (cache) module. A.The array accelerator modules in both controllers must be the same size. B.The array accelerator module can be replaced by a larger one. The extra space will not be used. C.The array accelerator module can be replaced by a smaller one. The cache will be switched off. D.If you have only different size modules available, you must power off the array during replacement. Correct:A

10. Which rule applies for spare drive configuration with the Storage Management Utility for the MSA1510i? A. A spare disk must be the same speed as the other drives in the array. B. A spare disk can be mixed with SCSI and SATA drives in the same array. C. A spare disk must be the same size (or smaller) as the other drives in the array. D. A spare disk must be the same type (SCSI or SATA) as the other drives in the array. 1.Click the Exhibit button. Which LED on the MSA1000 controller indicates a failure on a configured hard disk? A.LED 9 B.LED 15 C.LED 16 D.LED 17 Correct:B 2.The MSA1000 controller display module can hold up to 100 messages. Once the maximum is reached, the older messages will be ____. A.copied to the connected host using ACUXE B.copied to the connected host using the serial line C.deleted D.copied to the connected metadata part of the disks Correct:C 3.The customer has a single controller MSA1000 configuration. What is the recommended action to replace the failed controller? A.Power down the MSA1000. Remove the failed controller and install the old cache module in the replacement controller.

B.Push the right arrow push button on the front panel to clear the cache of the controller and replace the failed controller. C.Replace the failed controller online, with a new cache installed. D.Push the left arrow push button on the front panel to clear the cache of the controller and replace the failed controller. Correct:A 4.What is the recommended action to take when a controller fails in a redundant MSA1000 configuration? A.Power off the MSA1000 and replace the failed controller. B.Replace the failed controller online. C.Push the right arrow push button on the front panel to failover the controller and replace the failed controller. D.Modify the zoning so that the MSA1000 is not accessible during the online replacement of the failed controller.
| English | Chinese(Traditional) | Chinese(Simplified) | 3
KillTest Information Co., Ltd. All rights reserved.

Correct:B 5.Click the Exhibit button. The EMU in a MSA1000 has detected a temperature problem. Which LED of the enclosure status indicators reports the problem and how does the LED display the error condition? A.LED 1 is off. B.LED 2 is amber. C.LED 3 is off. D.LED 3 is amber. Correct:D 6.Click the Exhibit button. Which LED on the MSA1000 controller indicates an error message was sent to the controller display? A.LED 9 B.LED 15 C.LED 16 D.LED 17 Correct:D 7.You are assigning DISK109 as a spare drive to array B containing logical drives 2 and 3. What is
| English | Chinese(Traditional) | Chinese(Simplified) | 4
KillTest Information Co., Ltd. All rights reserved.

the correct CLI (command line interface) command? A.ADD SPARE UNIT=2 DISK109 B.ADD SPARE ARRAY B DISK109 C.SET SPARE ARRAY B DISK109 D.SET SPARE UNIT 3 DISK109 Correct:A 8.Click the Exhibit button. On an MSA1000 disk, LEDs 1 and 2 are OFF, and LED 3 is ON. What is the possible cause for the status and which action should you take?. A.The drive is part of the selection of the array configuration utility. Do not remove this drive without verifying the configuration. B.The array is rebuilding. Do not remove this drive without verifying the configuration.

C.The array is performing an online expansion. Do not remove this drive without verifying the configuration. D.The drive failed and has been taken offline. You can remove the drive. Correct:D 9.You are replacing a defective power supply in a redundant MSA1000 configuration. Which statement is correct? A.Remove the power supply. Note the part number of the unit and order the replacement part. Install the replacement part when it arrives. B.Power off the MSA1000 during replacement to reduce the risk of personal injury. C.Replace both power supplies at the same time because they contain the cache battery assembly. D.Removing a power supply significantly changes the airflow in the cabinet. The remaining power supply will shutdown the array after 5 minutes. Correct:D 10.The customer has a redundant MSA1000 configuration. Identify the correct statement about replacing an array accelerator (cache) module. A.The array accelerator modules in both controllers must be the same size. B.The array accelerator module can be replaced by a larger one. The extra space will not be used.
| English | Chinese(Traditional) | Chinese(Simplified) | 5
KillTest Information Co., Ltd. All rights reserved.

C.The array accelerator module can be replaced by a smaller one. The cache will be switched off. D.If you have only different size modules available, you must power off the array during replacement. Correct:A 11.Which statement about blanking panels is correct? A.The drive blanking panels are not necessary and can be removed. B.The interconnect blanking panel is not necessary and can be removed. C.One drive blanking panel at a time can be removed. D.Install blanking panels in every empty slot to avoid thermal failures. Correct:D 12.Click the Exhibit button. How does LED number 2 appear when power is supplied to the MSA1000 and the power switch in the front is switched to on? A.Flashing green B.Green C.Off D.Amber Correct:B 13.What are the correct statements about Fibre Channel cable routing or handling? Select THREE. A.You must firmly attach the cables to the cabinet with cable ties. B.Route cables at a 90 degree angle with a bending radius less than 2.5 cm/1 inch. C.Never bend the cables with a bending radius less than 7.62 cm/3 inch. D.When removing a cable from a transceiver, pull on the cable, not on the connector. E.If you must use cable ties, do not tighten them completely around Fibre Channel cables. F.Excess Fibre Channel cables should be coiled and tied loosely. Correct:C E F 14.Click the Exhibit button. On an MSA1000 disk, all LEDs are OFF. What are possible causes for the status and which actions should you take? Select TWO.
| English | Chinese(Traditional) | Chinese(Simplified) | 6
KillTest Information Co., Ltd. All rights reserved.

A.The array is rebuilding. Do not remove this drive without verifying the configuration. B.The array is performing an online expansion. Do not remove this drive without verifying the configuration. C.The drive is not configured as part of an array. You can remove the drive. D.The drive is part of the selection of the array configuration utility. Do not remove this drive without verifying the configuration. E.The drive is configured as a hot spare. If needed, you can remove the drive. Correct:C E 15.Click the Exhibit button. Which LED indicates the MSA1000 controller is active or passive? A.LED 9 B.LED 15 C.LED 16 D.LED 17 Correct:A 16.You have a configuration with 3 virtual disks configured in one array. One virtual disk is RAID 0, one is RAID 5 and one is ADG. Identify the correct statements if one hard drive has failed and you remove a wrong (running) drive from this array. Select TWO.
| English | Chinese(Traditional) | Chinese(Simplified) | 7
KillTest Information Co., Ltd. All rights reserved.

A.ADG is still online. B.ADG has data loss when you remove the wrong drive. C.RAID 5 is still online. D.RAID 5 has data loss when you remove the wrong drive. E.RAID 5 has data loss after first drive failure. Correct:A D 17.The customer has a redundant MSA1000 configuration in a Windows 2000 environment. Identify the recommended procedure to replace the array accelerator (cache) module from the active controller. A.The module can be replaced at any time because it is a hotswappable component. B.The replacement can only be done on the passive controller. To do the failover, you must remove the active controller. C.The replacement can only be done on the passive controller. To do the failover, you must failover all LUNs using the Secure Path GUI. D.The replacement can only be done on the passive controller. To do the replacement, you must power off the MSA1000. Correct:C 18.Which actions must you take to replace a failed hard drive? Select TWO. A.Examine the EMU status to determine if it is overheating. B.Examine the front panel LEDs to verify there is no ongoing I/O from the host. C.Examine the drive LED indicators to identify the failed drive and any ongoing background operation. D.Examine the power supply LED to determine if there is an airflow problem. E.Examine the front panel display to identify the failed drive and any ongoing background operation. Correct:C E 19.You are replacing a defective blower in a redundant MSA1000 configuration. Which statement

is correct? A.Although removing a blower does not change the airflow within the enclosure, do not remove the blower until the replacement part is available. B.Power off the MSA1000 during replacement to reduce the risk of personal injury. C.Replace both blowers at the same time because when one blower is defective, the other may fail soon. D.Removing a blower significantly changes the airflow in the cabinet. The power supply will shutdown the array after 5 minutes. Correct:A 20.Which CLI (command line interface) command can be used to list the current ACL (access control list)? A.SHOW CONNECTIONS /ACTIVE B.SHOW CONNECTIONS C.SHOW ACL D.ADD ACL Correct:C 21.You have a failed drive in a redundant MSA1000 configuration. The array has an online spare drive and the rebuild is running. What is the recommended procedure for replacing the failed hard drive?
| English | Chinese(Traditional) | Chinese(Simplified) | 8
KillTest Information Co., Ltd. All rights reserved.

A.The rebuild has no influence replace the online spare during the rebuild. B.The rebuild has no influence replace the failed drive during the rebuild. C.Replace the failed drive during the rebuild only if the drive fault indicator is on. D.Never replace a drive when a rebuild is running in the background replace the failed drive after the rebuild is complete. Correct:D 22.The customer has a redundant MSA1000 configuration in a Windows 2000 environment. What is the recommended procedure to replace the active MSA1000 controller? A.Only a passive controller can be replaced. The active controller cannot be replaced. B.Only a passive controller can be replaced. To do the failover, you must remove the active controller. C.Only a passive controller should be replaced. To do the failover, you must failover all LUNs using the Secure Path GUI. D.Only a passive controller should be replaced. To do the replacement, you must power off the MSA1000. Correct:C 23.Click the Exhibit button. The EMU of an MSA1000 is not operating normally. Which LED of the enclosure status indicators reports the problem and how does the LED display the error condition? A.LED 1 is off or solid. B.LED 1 is flashing green. C.LED 2 is off. D.LED 2 is amber. Correct:A

24.What happens if a blower assembly fails? A.The LED on the failing fan is off and the fan of the other power supply operates at higher speed. B.The LED on the power supply with the failing fan is off and the fan of the other power supply operates at normal speed. C.The LED on the power supply with the failing fan is amber and the fan of the other power supply operates at higher speed. D.The LED on the power supply with the failing fan is off and the fan of the other power supply operates at
| English | Chinese(Traditional) | Chinese(Simplified) | 9
KillTest Information Co., Ltd. All rights reserved.

higher speed. Correct:A 25.What are indicators of a temperature problem within the MSA1000 enclosure? Select TWO. A.An error message is displayed in the front panel. B.The enclosure status indicators are flashing. C.The internal alarm activates. D.The enclosure status indicator fault LED is illuminated. E.The integrated EMU LED is illuminated. Correct:A D 26.Which precautions must you take before replacing a nonhotpluggable part of an MSA100? Select TWO. A.Take appropriate Electrostatic Discharge (ESD) precautions. B.Disable the SSP settings over ACUXE. C.Modify the zoning so that the MSA1000 is not accessible. D.Power off an external Fibre Channel switch if there is a Fibre Channel connection. E.Disconnect all AC power cords from the MSA1000. Correct:A E 27.Identify the correct statement about removing a hard drive from a RAID 0 configuration. A.Replacing a hard drive is allowed if the drive has failed. User data is still available if there is a spare drive assigned to the array. B.Replacing a hard drive is allowed if the drive has failed. User data is lost. You have to do a restore from a valid backup. C.Replacing a hard drive is allowed for an online drive. User data is still available if there is a spare drive assigned to the array. D.Replacing a failed hard drive from a RAID 0 must be done while the MSA1000 is powered off. Correct:B 28.You have a redundant MSA1000 installation running Windows 2000. You moved the Secure Path manager software to a different client and updated the Secure Path agent configuration on the host which accesses the MSA1000. No information is displayed in the Secure Path manager window. What may be the causes? Select TWO. A.The Secure Path agent service must be restarted to update the configuration changes. B.It is not possible to change the Secure Path manager host. C.The MSA1000 must be restarted to reflect the changes. D.The management host cannot resolve the network name of the agent host. E.Zoning may be preventing the Secure Path manager from accessing the agent.

Correct:A D 29.Click the Exhibit button. You have a redundant MSA1000 configuration with host ABC accessing logical drives on the MSA1000. You install a second host XYZ to access logical drives. Both hosts run Windows 2000. Why are you unable to access the MSA1000 from Host XYZ? Select TWO.
| English | Chinese(Traditional) | Chinese(Simplified) | 10
KillTest Information Co., Ltd. All rights reserved.

A.SSP (Selective Storage Presentation) is enabled, but not configured for host XYZ. B.SSP (Selective Storage Presentation) is disabled and not configured for host XYZ. C.Zoning is enabled on the switches, but not configured for host XYZ. D.Zoning is enabled on the switches, but not configured for host ABC. E.Secure Path is installed on host XYZ which prevents the host from accessing any logical drive. Correct:A C 30.In a redundant MSA1000 configuration, what is the recommended action if a controller fails during an expansion process? A.Power off the MSA1000 and replace the failed controller. B.Replace the failed controller online. C.Push the right arrow push button on the front panel to failover the controller and replace the failed controller. D.Remove the failed controller and install the old cache module in the replacement controller. Correct:D

Which MSA30 component determines whether it is a single or dual bus shelf?


A.

238875813 2

SCSI I/O module of the MSA30

B. C. D.

jumpers on the backplane of the shelf software on the attached MSA controller environmental monitoring unit of the MSA30

What should be done after installing the host bus adapter (HBA) driver on the host using the MSA1500cs Support Software CD?
A.

238875821 2

Check the MSA1500 web site for an update.

B. C.

Check the web site of the operating system vendor for an update. Use the Fibre Channel update software to determine the primary HBA.

Obtain the latest version from the HBA manufacturer and update the driver. Which service must be running to back up or restore the configuration files on the MSA1000 Fabric Switch 2/8?
A.

D.

238875827 2

RPC or FTP

B. C. D.

FTP or SNMP FTP or RSHD RSHD or SNMP

How is the RJ45-connector on the MSA20 SCSI I/O module used?


A.

238875833 2

to configure the MSA20

B. C. D.

to connect to the enclosure address bus as service port (for HP service technicians only) as a link to another MSA20 in a fully redundant configuration

What does the 1G or 2G LED on the Fibre Channel I/O module indicate?
A.

238875843 2

Port has auto-negotiated to a good 1- or 2-Gb link.

B. C. D.

There is a single path or multipath MSA1500cs configuration. Port is connected to a first or second generation fabric switch.

Port is being used by the primary or secondary MSA1000 controller. What are indicators of a temperature problem within the MSA1000 enclosure? (Select two.)
A.

238875847

The internal alarm activates.

B. C. D. E.

The integrated EMU LED is illuminated. The enclosure status indicators are flashing. An error message is displayed in the front panel. The enclosure status indicator fault LED is illuminated.

What is the default username and password of the HP MSA1510i when logging in to the Storage Management Utility?
A.

238875853 2

root, root

B. C. D.

root, password admin, password administrator, administrator

A customer reports a failure with the SCSI I/O module on SCSI bus 1. Click the affected component.

You are replacing two failed drives of a RAID ADG array at an MSA1500cs on a Friday evening before the weekly backup on Saturday evening. How should you set the controller settings to ensure maximum data protection?
A.

238875863 2

Low to allow priority data to rebuild

B. C. D.

High to take priority away from I/O Rebuild to enable the rebuild process Express to enable high-speed rebuild

What do you select when you decide to use a fault-tolerance level of Distributed Data Guarding?
A.

238875864 2

RAID 0

B.

RAID 5

C. D.

RAID 1+0 RAID ADG

How many logical drives are supported by the MSA1000?


A.

238875867 2

28

B. C. D.

32 38 44

Which statement is correct to expand an array, or extend or migrate a logical drive?


A.

238875869 2

No other expansion, extension or migration can occur simultaneously in the same SAN. No other expansion, extension or migration can occur simultaneously on the same controller. Another expansion, extension or migration may be started at any time on the same controller.

B. C. D.

No other expansion, extension or migration can occur simultaneously in the same Array Configuration Utility. How can you access the Command Line Interface of the different MSA systems? (Select two.)
A. B. C. D. E.

MSA1510i systems require telnet connections. MSA1510i systems support both serial or telnet connections. MSA1000, MSA1500cs, and MSA1510i systems support serial connections. MSA1000, MSA1500cs, and MSA1510i systems require serial connections. MSA1000, MSA1500cs, and MSA1510i systems support both serial and telnet connections. Answer: B, C

In MSA1000 controllers, how are cache modules of different sizes supported?


A.

only supported in no-mirror mode not supported in any configuration supported only in single-path configuration supported in a multipath configuration if the total cache size in both controllers is the same Answer: B

Which Command Line Interface method provides security at LUN level?


A. B. C. D.

Access Control List Secure Socket Layer Selective Storage Presentation

Challenge Handshake Authentication Protocol Answer: A What is a best practice when configuring iSCSI targets?
A. B. C. D.

Each target must be in its own VLAN. Targets cannot be configured using SMU. Do not use the IP address of the original target. Initiators and targets must be on the same layer 2 Ethernet LAN. Answer: A

Anda mungkin juga menyukai