Anda di halaman 1dari 54

Content

MSC-18HRIN1; MSH-18HRIN1
MSE-09HRIN2; MSE-12HRIN2

PDF "pdfFactory Pro"


www.fineprint.cn

Content

Content
1.

Precaution........................................................................................................................... 1
1.1
1.2

2.
3.

Safety Precaution ................................................................................................................................. 1


Warning................................................................................................................................................. 1

Function .............................................................................................................................. 3
Dimension ........................................................................................................................... 5
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8

4.
5.
6.

Indoor unitAlfa ............................................................................................................................... 5


Outdoor unitAlfa ............................................................................................................................ 5
Indoor unitCorona.......................................................................................................................... 6
Outdoor unitCorona....................................................................................................................... 6
Indoor unit(Inverter Eco)....................................................................................................................... 7
Outdoor unit(Inverter Eco) .................................................................................................................... 7
Indoor unit(Inverter Star)....................................................................................................................... 8
Outdoor unit(Inverter Star).................................................................................................................... 9

Specification ..................................................................................................................... 10
Refrigerant cycle diagram ............................................................................................... 12
Operation limits ................................................................................................................ 13
6.1
6.2

7.

Cooling operation ............................................................................................................................... 13


Heating operation ............................................................................................................................... 13

Schematic diagram and Wiring diagram ........................................................................ 14


7.1.
7.2.

8.

Schematic diagram............................................................................................................................. 14
Wiring diagram.................................................................................................................................... 18

Installation details ............................................................................................................ 23


8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9

9.

Wrench torque sheet for installation................................................................................................... 23


Connecting the cables ........................................................................................................................ 23
Pipe length and the elevation ............................................................................................................. 23
Air purging of the piping and indoor unit ............................................................................................ 24
Pumping down (Re-installation) ......................................................................................................... 25
Re-air purging (Re-installation) .......................................................................................................... 26
Balance refrigerant of the 2-way, 3-way valves.................................................................................. 27
Evacuation .......................................................................................................................................... 28
Gas charging ...................................................................................................................................... 29

Pressure table................................................................................................................... 30
9.1
9.2

10.
10.1
10.2
10.3
10.4
10.5
10.6

MSH-18HRIN1.................................................................................................................................... 30
MSC-18HRIN1.................................................................................................................................... 30

Capacity table ................................................................................................................... 31


MSH-18HRIN1.................................................................................................................................... 31
MSC-18HRIN1.................................................................................................................................... 32
MSG-09HRI ........................................................................................................................................ 33
MSG-12HRI ........................................................................................................................................ 33
MSG-21HRI ........................................................................................................................................ 34
MSG-24HRI ........................................................................................................................................ 34

PDF "pdfFactory Pro" www.fineprint.cn

Content

11.

Electronic function........................................................................................................... 35
11.1.
11.2.
11.3.
11.4.
11.5.
11.6.
11.7.
11.8.
11.9.
11.10.
11.11.
11.12.
11.13.
11.14.
11.15.

12.
13.
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8

14

Display board...................................................................................................................................... 35
Protection............................................................................................................................................ 35
Fan-only mode.................................................................................................................................... 35
Cooling mode...................................................................................................................................... 35
Dehumidifying mode........................................................................................................................... 36
Heating mode ..................................................................................................................................... 36
Defrosting operation (Available for heating only). .............................................................................. 38
Outdoor low temperature protection (optional)................................................................................... 38
Automatic operation mode ................................................................................................................. 38
Manual switch..................................................................................................................................... 39
Timer Function.................................................................................................................................... 39
Sleep mode......................................................................................................................................... 39
Auto restart function ........................................................................................................................... 39
Turbo function ..................................................................................................................................... 39
Plasma................................................................................................................................................ 39

Model and Parameters ..................................................................................................... 40


Troubleshooting ............................................................................................................... 42
Indoor Unit Error Display .................................................................................................................... 42
Diagnostic chart.................................................................................................................................. 47
Resetting phenomenon often occurs during operation ...................................................................... 48
Operation lamp flashes and Timer lamp off ....................................................................................... 48
Operation lamp flashes and Timer lamp on ....................................................................................... 48
Operation lamp off and Timer lamp flashes ....................................................................................... 49
Operation lamp on and Timer lamp flashes ....................................................................................... 49
Operation lamp flashes, Timer lamp flashes ...................................................................................... 49

Characteristic of temperature sensor............................................................................. 50

PDF "pdfFactory Pro" www.fineprint.cn

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

1.
1.1

Precaution
Safety Precaution

n To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage.
n Before service unit, be sure to read this service manual at first.

1.2

Warning

Installation
n Do not use a defective or underrated circuit breaker.
Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
n For electrical work, contact the dealer, seller, a
qualified electrician, or an Authorized service center.
Do not disassemble or repair the product, there is risk of
fire or electric shock.
n Always ground the product.
There is risk of fire or electric shock.
n Install the panel and the cover of control box
securely.
There is risk of fire of electric shock.
n Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric
shock.
n Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
n Do not modify or extend the power cable.
There is risk of fire or electric shock.
n Do not install, remove, or reinstall the unit by
yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
n Be caution when unpacking and installing the
product.
Sharp edges could cause injury, be especially careful of
the case edges and the fins on the condenser and
evaporator.
n For installation, always contact the dealer or an
Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
n Do not install the product on a defective installation
stand.
It may cause injury, accident, or damage to the product.
n Be sure the installation area does not deteriorate
with age.
If the base collapses, the air conditioner could fall with it,
causing property damage, product failure, and personal
injury.
n Do not let the air conditioner run for a long time
when the humidity is very high and a door or a
windows is left open.
Moisture may condense and wet or damage furniture.
n Take care to ensure that power cable could not be
pulled out or damaged during operation.
There is risk of fire or electric shock.
n Do not place anything on the power cable.

There is risk of fire or electric shock.


n Do not plug or unplug the power supply plug during
operation.
There is risk of fire or electric shock.
n Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
n Do not place a heater or other appliance near the
power cable.
There is risk of fire and electric shock.
n Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
n Do not store or use flammable gas or combustible
near the product.
There is risk of fire or failure of product.
n Do not use the product in a tightly closed space for a
long time.
Oxygen deficiency could occur.
n When flammable gas leaks, turn off the gas and
open a window for ventilation before turn the
product on.
Do not use the telephone or turn switches on or off.
There is risk of explosion or fire.
n If strange sounds, or small or smoke comes from
product. Turn the breaker off or disconnect the
power supply cable.
There is risk of electric shock or fire.
n Stop operation and close the window in storm or
hurricane. If possible, remove the product from the
window before the hurricane arrives.
There is risk of property damage, failure of product, or
electric shock.
n Do not open the inlet grill of the product during
operation. (Do not touch the electrostatic filter, if the
unit is so equipped.)
There is risk of physical injury, electric shock, or product
failure.
n When the product is soaked (flooded or submerged),
contact an Authorized service center.
There is risk of fire or electric shock.
n Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
n Ventilate the product from time to time when
operating it together with a stove, etc.
There is risk of fire or electric shock.
n Turn the main power off when cleaning or
maintaining the product.

PDF "pdfFactory Pro" www.fineprint.cn

Service manual
There is risk of electric shock.
n When the product is not be used for a long time,
disconnect the power supply plug or turn off the
breaker.
There is risk of product damage or failure, or unintended
operation.
n Take care to ensure that nobody could step on or fall
onto the outdoor unit.
This could result in personal injury and product damage.

CAUTION
n Always check for gas (refrigerant) leakage after
installation or repair of product.
Low refrigerant levels may cause failure of product.
n Install the drain hose to ensure that water is drained
away properly.
A bad connection may cause water leakage.
n Keep level even when installing the product.
To avoid vibration of water leakage.
n Do not install the product where the noise or hot air
from the outdoor unit could damage the
neighborhoods.
It may cause a problem for your neighbors.
n Use two or more people to lift and transport the
product.
Avoid personal injury.
n Do not install the product where it will be exposed to
sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion,
particularly on the condenser and evaporator fins, could
cause product malfunction or inefficient operation.

Operational
n Do not expose the skin directly to cool air for long
periods of time. (Do not sit in the draft).
This could harm to your health.
n Do not use the product for special purposes, such
as preserving foods, works of art, etc. It is a

consumer air conditioner, not a precision refrigerant


system.
There is risk of damage or loss of property.
n Do not block the inlet or outlet of air flow.
It may cause product failure.
n Use a soft cloth to clean. Do not use harsh
detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the
plastic parts of the product.
n Do not touch the metal parts of the product when
removing the air filter. They are very sharp.
There is risk of personal injury.
n Do not step on pr put anything on the product.
(outdoor units)
There is risk of personal injury and failure of product.
n Always insert the filter securely. Clean the filter
every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner
and could cause product malfunction or damage.
n Do not insert hands or other object through air inlet
or outlet while the product is operated.
There are sharp and moving parts that could cause
personal injury.
n Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
n Use a firm stool or ladder when cleaning or
maintaining the product.
Be careful and avoid personal injury.
n Replace the all batteries in the remote control with
new ones of the same type. Do not mix old and mew
batteries or different types of batteries.
There is risk of fire or explosion.
n Do not recharge or disassemble the batteries. Do not
dispose of batteries in a fire.
They may burn of explode.
n If the liquid from the batteries gets onto your skin or
clothes, wash it well with clean water. Do not use the
remote of the batteries have leaked.
The chemical in batteries could cause burns or other
health hazards.

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

2.

Function
Indoor unit

Operation ON/OFF by remote controller

Sensing by room temperature


Room temperature sensor.
Pipe temperature sensor.

Room temperature control


Maintain the room temperature in accordance with the setting temperature.

Anti-freezing control in cooling


Prevent the water being freezed on evaporator by sensing
the evaporator pipe temperature in cooling mode

Work voltage (160v-253v)


High efficiency (30%)

Time Delay Safety control


Restarting is for approx. 3 minutes..

Indoor fan speed control

Tele Remote control (Optional)


Self-diag. function

Turbo wind, high, med, low, breeze.

Anti-cold function
Two-direction air vane
The unit will decide the louver direction according to operation mode.

Prevent the cold wind at


the beginning of unit start.

Sleep mode auto control


The fan is turn to low speed (cooling/heating).
The unit will be turn off at the seventh hour.

Independent dehumidification
The function is usually used in rainy days in
springtime or damp areas.

Air flow Direction control

The louver can be set at the desired position or swing up and


down automatically

Auto mode
The mode can be change by the room temperature.

Auto defrost
Auto-restart function
When the power supply is interrupted and then
restore, the air conditioners automatically
restore the previous function setting.

Flexible wiring connection

DSP High-speed Chip

Temp. Compensation
Driving heating at -15

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

Outdoor unit

Power relay control


The unit has 3 mins delay between continuously ON/OFF operations.

Low noise air flow system


Bird tail propeller fan makes the outdoor unit run more quietly.

Hydrophilic aluminum fin


The hydrophilic fin can improve the heating efficiency at operation mode.

4 way valve control


It is only operated in the heating operation mode except defrosting operation.

Anti-rust cabinet
Made from electrolytic zinc steel sheet and anti-rust coated components.

Valve protection cover


It protects the valves and prevents water from dripping.

Discharge pipe temperature protect

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

3.
3.1

Dimension
Indoor unitAlfa

Dimension
Mode

18K

920

293

224

Outdoor unitAlfa

Dimension
Mode
18K

W
845

H
695

D
335

L1

L2

L3

560

360

735

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

3.2

Indoor unitCorona

Dimension
Mode
18K

920

292

225

Outdoor unitCorona

Dimension
Mode
18K

W
845

H
695

D
335

L1

L2

L3

560

360

735

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

3.3

Indoor unit(Inverter Eco)

Dimension
Mode
7K
9K
12K

750
750
750

250
250
250

188
188
188

Outdoor unit(Inverter Eco)

Dimension
Mode

L1

L2

L3

7K

780

540

250

530

315

590

9K

780

540

250

530

315

590

12K

780

540

250

530

315

590

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

3.4

Indoor unit(Inverter Elite)

Dimension

7K

710

250

190

9K

710

250

190

12K

790

265

195

Mode

Outdoor unit(Inverter Elite)

Dimension
Mode

L1

L2

L3

7K

780

540

250

530

315

590

9K

780

540

250

530

315

590

12K

780

540

250

530

315

590

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

3.5

Indoor unit(Inverter Star)

Dimension
Mode

9K

750

250

205

12K

815

280

215

21K

1080

330

222

24K

815

280

215

Outdoor unit(Inverter Star)

Dimension
Mode

L1

L2

L3

9K

780

540

250

530

315

590

12K

780

540

250

530

315

590

21K

845

695

335

560

360

735

24K

845

695

335

560

360

735

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

4.

Specification

Ac AlfaAc Corona, Inverter Elite


Model

MSC-18HRIN1

MSE-09HRIN2

MSE-12HRIN2

Ph-V-Hz 1, 220-240V~, 50Hz

MSH-18HRIN1

1, 220-240V~,50Hz

1, 220-240V~, 50Hz

1, 220-240V~, 50Hz

Capacity

Btu/h

18000

18000

9000

12000

Input

1670

1720

1100

1400

Rated current

9.0

7.5

5.1

6.4

EER

Btu/w.h

10.8

10.5,

8.2

8.6

Capacity

Btu/h

20000

19000

12000

15000

Input

1830

1790

1400

1700

Rated current

9.9

7.7

6.3

7.5

COP

W/W

3.2

3.11

8.6

8.8

15.5

18

12

18

Power supply

Cooling

Heating

Max. current
Starting current

Compressor

Indoor \fan motor

9.0

9.0

Model

BA160X2CS-20KU

BA160X2CS-20KU

BG130X1C-20FZ

BG130X1C-20FZ

Type

Rotary

Rotary

Rotary Inverter

Rotary Inverter

Brand

TOSHIBA

TOSHIBA

TOSHIBA

TOSHIBA

Capacity

Btu/h

16140

16140

9468

9468

Input

1630

1630

890

890

Rated current(RLA)

10.95

10.95

5.7

5.7

Locked rotor Amp(LRA) A

55

55

Thermal protector

CS-74

CS-74

CS-74

CS-74

Capacitor

uF

No

No

No

No

Refrigerant oil

ml

750

750

370

370

Model

RPG28C

RPG28C

RPG13H

RPG13D

Brand

Welling

Welling

Welling

Welling

Input

45

55

39.5

44

Capacitor

uF

1.5

1.5

1.2

1.5

Speed(hi/mi/lo)

r/min

1200/1150/1000

1140/1060/980

1250/1100/850

1180/1000/850

Indoor air flow (Hi/Mi/Lo)

m3/h

800/700/600

800/700/600

520/460/410

580/500/420

Indoor noise level (Hi/Mi/Lo)

dB(A)

44/40/37

44/40/37

40/38/35

40/38/35

Model

YDK53-6K

YDK53-6C

YDK24-6F

YDK25-6-3

Brand

Welling

Welling

Welling

Welling

Outdoor fan motor

Input

130

125

56

75

Capacitor

uF

3.0

3.0

2.5

2.0

Speed

r/min

750

800

800

900

Outdoor air flow

m3/h

2500

2500

1600

1700

Outdoor noise level

dB(A)

58

58

58

58

Refrigerant type R410A

1650

1770

840

1200

Liquid side/ Gas side

mm

6.35/12.7

6.35/12.7

6.35/9.53

6.35/12.7

Max.

pipe length

10

15

10

10

Max.

in level

Operation temp

17-30

17-30

17-30

17-30

Ambient temp

-15-43

-15-43

-15-50

-15-50

Application area

m2

28-45

28-45

Refrigerant piping

Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different
as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.
10

PDF "pdfFactory Pro" www.fineprint.cn

Service manual
Model

MSG-07HRIN2

MSG-09HRIN2

MSG-12HRIN2

220-240V~ 50Hz

220-240V~ 50Hz

220-240V~ 50Hz

BTU/H

7000(2700~9000)

9000(2730~10600)

12000(3070~13300)

780(305~990)

990(305~1180)

1340(334~1494)

4.8(1.35~6.2)

4.5(1.2~6.6)

5.8(1.60~7.60)

9.0, 2.62

9.0, 2.62

9.0, 2.61

9000(2700~11000)

12000(2730~14000)

15000(3070~17060)

Power source
Capacity
Cooling

Input
Running current
EER

BTU/W.H,W/W

Capacity
Heating

BTU/H

Input

940(280~1140)

1240(283~1450)

1560(320~1773)

Running current

4.4(1.35~6.7)

5.5(1.45~9.3)

6.8(1.6~10.6)

W/W

2.81

2.82

2.82

1.0

1.0

1.2

2300

2300

2600

Model

BG130X1C-20FZ

BG130X1C-20FZ

BG130X1C-20FZ

Type

Rotary

Rotary

Rotary

COP
Moisture removal

L/h

Max. input consumption

Inverter

Inverter

TOSHIBA

TOSHIBA

TOSHIBA

370

370

370

POE

POE

POE

800

800

1200

RPG13H

RPG13H

RPG13C

Welling

Welling

Welling

1.2uF/450VAC

1.2uF/450VAC

1.5uF/450VAC

Hi/Mid/Lo speed ( rpm)

1050/950/750

1100/1000/800

1060/900/800

Air flow(indoor)

Hi/Mid/Lo

500/410/320

520/430/330

560/460/380

Noise level (indoor)

Hi/Mid/Lo

dB(A)

35/32/26

36/32/26

36/32/26

YDK25-6-3

YDK25-6-3

YDK25-6-3

2.5uF/450VAC

2.5uF/450VAC

2.5uF/450VAC

Brand

Welling

Welling

Welling

dB(A)

51

51

53

750*250*188

750*250*188

815*280*195

830*336*280

830*336*280

915*360*275

8.5/11

8.5/11

11/14

780*540*250

780*540*250

780*540*250

910*575*335

910*575*335

910*575*335

kg

37/40

37/40

40/43

Liquid side

mm

6.35

6.35

6.35

Gas side

mm

9.53

9.53

12.7

Max. refrigerant pipe length

10

10

10

Max. difference in level

Operation temp

17~30

17~30

17~30

Ambient temp

-15~45

-15~45

-15~45

14-18

18-24

20-30

Compressor

Brand

Inverter

Refrigerant oil

ml

Refrigerant oil type


Capacitor

uF

Refrigerant R407C

g
Input

Brand
Indoor fan motor

Capacitor

uF

Speed level

m3/h

Input
Outdoor fan motor

Noise lever (outdoor)

Capacitor

dimension
Indoor unit

Packing

uF

(W*H*D)
(W*H*D)

Net/Gross weight
dimension
Outdoor unit

Packing

(W*H*D)
(W*H*D)

Net/Gross weight

Refrigerant piping

Application area

kg

M2

11

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

5.

Refrigerant cycle diagram

12

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

6.
6.1

Operation limits
Cooling operation

Outdoor unit air temp. DB

Indoor air temp. DB


Note: The chart is the result from the continuous operation under constant air temperature conditions.
However, excludes the initial pull-down stage.

6.2

Heating operation

Indoor air temp. DB

Outdoor unit air temp. DB


Note: The chart is the result from the continuous operation under constant air temperature conditions.
However, excludes the initial pull-down stage.

13

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.
7.1.

Schematic diagram and Wiring diagram


Schematic diagram

7.1.1 Display board(MSH-18HRIN1,MSC-18HRIN1)


1

+5
R7
221
D

Q4

R8

4
5

CN1

Vcc

Dsb

Q7

Q0

Q6

Q1

Q5

Q2

Q4

Q3

MR

GND

CP

14
13
12

LED1

DISP2

11

LED2

LED3

10
9
8

74HC164

8LED
7
6
5
4
3
2
1

FROM INDOOR PCB

R12 391
R13 391
R14 391

R11 391

Dsa

9012

102

R9 221

R17 221

R15 221
R16 391

+5

104
C1

IC1

CLK
DATA
DIGI
+5V
REMOTE
GND

DEF R
+5

TIME Y

+5

E2
47u/16V

C3

C6

104

102

AUTO G

R6
221
Q1
9012
R5
102
+5
Q2
9013

R1 102

R10
151
REC1

R4 221
dig.1 g

DISP1
+5

R3 221

d dp e

c dig.2

C5

E4

104

10u/16V

Q3
9012

R2 102

Size

FCSMNo.

DWGNo.

Rev

B
Scale
1

Sheet
0 of 0

7.1..2 Indoor main PCB(MSH-18HRIN1,MSC-18HRIN1)


1

CN1
1

R2 51/1W

C2

333/250VAC

T1

L1
TR1
BT131

R11 C12
100K 104

R1
2K

FAN_IN

+5V
R3
IC1 PC817

ZR1
14D681K

CN9

STEP3

560

PTC1
82RM

3
4
5

BUZZ

INDOORFAN

1 CN2

CHUCHEN

2 TRANS_IN

INDOORFAN'

STEP4

C5
333/250VAC

STEP2

IC4

STEP1

IN4007
t

C25
1.2(1.5)uF/450V

4
D

R4
R5
D5
11K/2W 11K/2W

DZ2
12V

3.15A/250V

E2
470uF/25V

T2

CN10

FUSE1

8
C7

IN1

OUT1

IN2

OUT2

IN3

OUT3

IN4

OUT4

IN5

OUT5

IN6

OUT6

IN7

OUT7

VSS

VDD

104

Vin

C3

D3

Vout

IC3

7805

Vin

C4

E3

104

E1

+5V
Vout

470uF/16V

104

IC7

7812

Vin

GND

E5

D8

18

RXD
1

D7
C

17

TXD
IN4007*4

C8

ISO+12V

Vout

P-1

E6

472

C9

19

CLK

104

GND

20

LED_C

21

104
2

D9

C1

470uF/25V
ISOGND
2.5M

POWER CIRCUIT

22

RST

X1
1000uF/25V

23

R10
1M

24
25

+5V
C10
104
1 IC6

D10
IN4007

C16
471/250V

C14

PC817

102

4 IC10 PC851

R20

IN4749

DZ1 C13
24V
473

R43
R23
5.1K

R17
2K/2W

R18
5.1K

+5V

C15
102

11K/2W
R19
100K

STEP2
STEP3
STEP4

R22
12K

DIGI_C

CN9

D11

L1

10K

10K

29
30
31
32

P32

P24

P31

VPP

P30

RESET

P11

X2

P10

X1

R9

Q1
9013

5.1K
1

2
ISO+12V

2K

ISOGND

ANI3

P25

ANI2

P26

ANI1

P00

ANI0

P01

P53

P02

P52

P03

P51

P04

P50

16

CHUCHEN

15

RST

ZERO

13
12

IC9 7042
2

FAN_BACK

14

DATA

+5V

R13
E8
47uF/16V

REMOTE

11

C26
104

10K

SDA

10

SCL
+5V

9
8
7
6

4
3
2
1

R14

R15

R16

10K

10K

10K

T2_pipe

CN7

T1_room

LED_C
CLK

SW_KEY
SELECT3

+5V

REMOTE

SELECT2

7
6
5
4
3
2
1

DATA

DIGI_C

CN4

R30 100

C18
102

3
2
1

SELECT1

DISPLAY

R40 5.1K

12K R39
12K
R37

Q3
9013

C19
R28
10K

C23
223

C22
223

+5V

ZERO

R29
10K

SCL
SDA

8
7
6
5

IC11 24C04
VCC
WC
SCL
SDA

A0
A1
A2
GND

104
1
2
3
4

+5V
D15
IN4148
SELECT3

SELECT2

FAN_BACK

CN14

SW_KEY

T2_pipe

R27 2K
E12

R36
8.06K

14

PDF "pdfFactory Pro" www.fineprint.cn

+5V

C21
104

SW1

+12V

+5V

2
3
2
1

5.1K

C20
103

CN11

R35
10K

CN13

R34

FAN_BACK
J3

PC817

12K

10K

J2

VSS

VDD

R38

D14 1N4007
D13 1N4007
B

R32

SELECT1

28

P33

P23

+5V

R31

4 IC5
R7
1K
R6

E10 100uF/16V

+5V

+5V

J1

27

P20

P22

+5V

COMMUNICATE CIRCUIT

R33

TXD

+5V

26

P21

R25
5.1K

100uF/35V

1
2 CN6

10

IC/ULN2003

B1

R8
1K

11
INDOORFAN'

2K

CN10

IN4007

CN8
S

12

Q2 9013
R26

1
2 CN12

+12V

uPD789189(32P)

11K/2W

1
2

STEP1

R24
680

R21

E9

INDOORFAN
E7
100uF/16V
BUZZ

RXD

1K

+5V

ISO+12V

13

IC8

2200uF/25V
D6

14

C11

D4

TRANS_OUT

14.5VAC 200mA

1
2
3
4
5

15

+12V

CORTROL CIRCUIT

E4

104

1000uF/25V

+12V
1

GND

D1
D2

4
3
2
1

7812

CN5

IC2

GND

IN4007*4

14.5VAC 350mA

CN8

16

47uF/16V

T2_pipe

T1_room

C17
223

R41
8.06K

R42
E11
47uF/16V

2K

T1_room
C24
223

Service manual

7.1.3 Outdoor main PCB(MSH-18HRIN1,MSC-18HRIN1)


1

+5
D

CZ2

10
9
8
7
6
5
4
3
2
1

Pro
+12

C25
C4
R6

U+
UV+
VW+
W-

R5

LED

R4

R29

+5V

R3
C23

R2
R1
L4

R18

LED

+5V

R7

R32

64 63 62 61 60 59 58 57 56 55 54 53 52

C7

R9

IPM

Pro
+5V

+5V
R31

4148

C1

D2
D5
AC-IN

D3

R21

R11
C17

Current Detect

R12

CT1

ADCIN04
C11

C10

R22

VDD
51 VSS
IC2
50
PTM
1
49 IOPC5
FAN
48
3
IOPC4
4-WAY
5
47 IOPC3
7
46
IOPC2
9
45
SCIRX/IOPA1
RXD
11
44
SCITX/IOPA0
TXD
13
43
IOPC1
POWER
15
42 VDD
+5V
41
VSS
40 IOPC0
+5V
39
EMU1
R16
38 EMU0
37
XTAL2
36
XTAL1
XTAL1
35
VDD
+5
34
VSS
33
C14
C15
C16

1 VDD
2 VSS
3
4
5 PD0
6 CAP3/IOA5
7 CAP2/QEP1/IOPA4
8 CAP1/QEP0/IOPA3
9 VDD
TMS320F242
10 VSS
(64QFP)
11
12
13 VSSA
14 VDDA
15 ADCIN07
16 VREFHI
17 VREFLO
18 ADCIN06
19 ADCIN05

C6

R10

+5V

R8

Compress Top

IOPC6
IOPC7
TP2
TP1
Vccp
PWM1/PA6
PWM2/PA7
PWM3/PB0
Vdd
Vss
PWM4/PB1
PWM5/PB2
VDD0

2
1

+5V

R30

20 21 22 23 24 25 26 27 28 29 30 31 32
ADCIN03
ADCIN02
ADCIN01
ADCIN00
NC
Vss
/RESET
TCK
TDI
TDO
TMS
/TRST

CN1

LED

+5V

FAN'
4-WAY'

2
4
6
8
10
12
14
16

CN1
11
10
9
8
7
6
5
4
3
2
1

+12V

AC-IN
AC-IN
FAN'

4-WAY'
GND
TXD
RXD
+5V
+12V
POWER1

CON11
J3(Comm Select)

link to power circuit

R25

+5
2
1

CN4

R34

2
1

R14

CN2
2
1
Outdoor Pipe Sensor

C20

+5V

C8

+5

C9
IC1

R24

EVP

R12

R15

R13

C22

C19

R33

C21
OUT-TEMP

+5

13
11
9
7
5
3
1

+5V
Outdoor Entironment Sensor

CN10

+5

14
12
10
8
6
4
2

R23

1
2
3

R36

R35

C13

C12

7.1.4 Outdoor power PCB(MSH-18HRIN1,MSC-18HRIN1)


1

DB2

Filter

FS1
20A/250VAC

474/250V
C1 14D681

RL3-4

474/250V

H38-20A-6MH
C5
472

T1

C2

R18J04D

FS2
3.15A/250VAC

V+

560uF/400V *6

L2 R1812
AC

V+

AC

V-

AC

VL1

POWER1
RL3

R8025

C6

P-5

C7

C82

C81

C83

C84

C85

C86

P-4

C8

103

50uF/450V

103

DB1

14D681

P-2

AS1

ZMR1

L3

+12V

C4
472

ZMR2

AC

PTC1

IPM BOARD

P-6

P-3

P-1

C
T3

CN1

AC-IN
H.FAN
L.FAN
4-WAY
GND
TXD
RXD
+5V
+12V
POWER1

CN4

FAN.H
R30
3.5K/7W
2

CON11
R28
12K

POWER1

IC5

PC851

3
4

C23
471/250V

D1
IN4007

FAN

11
10
9
8
7
6
5
4
3
2
1

CN7
+12V

CAP
RL2

C15
2.5U

CN5

COM

+5

RXD
+5V

IC6

PC817

4-WAY

TXD
+12V

RL1
2
1

C21

CN6

R26
5.1K

104

4-WAY

Power Circuit
1

15

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.1..5 Indoor main PCB(Inverter Eco)

16

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.1.6 Outdoor main PCB(Inverter Eco/Elite)

17

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.2.

Wiring diagram

7.2.1 MSH-18HRDN1

18

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.2.2 MSC-18HRIN1

19

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.2.3 MSE-09HRIN2, MSE-12HRIN2

20

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

7.2.4 MSG-07HRIN2, MSG-09HRIN2, MSG-12HRIN2


1 Indoor unit 7/9K

Indoor unit 12K

21

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

3. Outdoor unit

22

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.
8.1

8.2

Installation details
Wrench torque sheet for installation
Outside diameter

Torque

mm

inch

Kg.m

6.35

1/4

1.8

9.52

3/8

4.2

12.7

1/2

5.5

15.88

5/8

6.6

19.05

3/4

6.6

Connecting the cables

The power cord of connect should be selected according to the following specifications sheet.
Grade

8.3
Capacity
Btu/h
7k~12K

18K~28K

Unit

7K

9K

12K

16K

18K

mm2

1.0

1.0

1.5

2.5

2.5

Pipe length and the elevation


Pipe size

Standard
length
(m)

Max.
Elevation
B (m)

Max.
Elevation
B (m)

Additional
refrigerant
(g/m)

GAS

LIQUID

3/8 (9.52)

1/4 (6.35)

10

30

1/2 (12.7)

1/4 (6.35)

10

30

1/2 (12.7)

1/4 (6.35)

15

30

5/8 (15.88)

1/4 (6.35)

10

20

30

5/8 (15.88)

3/8 (9.52)

10

20

65

In case that
more than 5m.

Caution:
Capacity is base on standard length and maximum allowance length is base of reliability.
Oil trap should be install per 5-7 meters.

23

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

8.4

Air purging of the piping and indoor unit

Required tools:
Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector.
Note:
The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping, it will
affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit.
Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it
prevents the gas leakage from the refrigeration cycle.

Procedure
1. Recheck the piping connections.
2. Open the valve stem of the 2-way valve
counterclockwise approximately 90, wait
10 seconds, and then set it to closed
position.
Be sure to use a hexagonal wrench to operate
the valve stem
3. Check for gas leakage.
Check the flare connection for gas leakage
4. Purge the air from the system.
Set the 2-way valve to the open position and
remove the cap from the 3-way valves
service port.
Using the hexagonal wrench to press the
valve core pin, discharge for three seconds
and then wait for one minute.
5. Use torque wrench to tighten the service
port cap to a torque of 1.8 kg.m. (18n.m)

6. Set the 3-way valve to the opened


position.
7. Mounted the valve stem nuts to the 2-way
and 3-way valves.
8. Check for gas leakage.
At this time, especially check for gas leakage
from the 2-way and 3-way stem nuts, and
from the service port.
Caution:
If gas leakage is discovered in step (3) above,
take the following measures.
If the leaks stop when the piping connections are
tightened further, continue working from step (4).
If the gas leaks do not stop when the connections
are retightened, repair the location of the leak,
discharge all of the gas through the service port,
and then recharge with the specified amount of
gas from a gas cylinder.

24

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.5

Pumping down (Re-installation)

Procedure
1. Confirm that both the 2-way and 3-way valves are set to the opened position.
Remove the valve stem caps and confirm that the valve stems are in the opened position.
Be sure to use a hexagonal wrench to operate the valve stems.
2. Operate the unit for 10 to 15 minutes.
3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the
3-way valve.
Connect the charge hose with the push pin to the gas service port.
4. Air purging of the charge hose.
Open the low-pressure valve on the charge set slightly to purge air from the charge hose.
5. Set the 2-way valve to the close position.
6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0.1MPa.
7. Immediately set the 3-way valve to the closed position.
Do this quickly so that the gauge ends up indicating 0.3 to 0.5Mpa.
8. Disconnect the charge set, and amount the 2-way and 3-way valves stem nuts and service
port caps.
Use a torque wrench to tighten the service port cap to a torque of 1.8 kg.m.
Be sure to check for gas leakage.

25

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.6

Re-air purging (Re-installation)

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the closed position.
2. Connect the charge set and a charging cylinder to the service port of the 3-way valve.
Leave the valve on the charging cylinder closed.
3. Air purging.
Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare nut
on the 2-way valve approximately 45 for 3 seconds then closing it for 1 minutes; repeat 3 times.
After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve.
4. Check the gas leakage.
Check the flare connections for gas leakage.
5. Discharge the refrigerant.
Close the valve on the charging cylinder and discharge the refrigerant until the gauge indicate 0.3 to
0.5 Mpa.
6. Disconnect the charge set and the charging cylinder, and set the 2-way and 3-way valves to
the open position.
Be sure to use a hexagonal wrench to operate the valve stems.
7. Mount the valve stems nuts and the service port cap.
Be sure to use a torque wrench to tighten the service port cap to a torque 18N.m.
Be sure to check the gas leakage.

26

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.7

Balance refrigerant of the 2-way, 3-way valves

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the open position.
2. Connect the charge set to the 3-way valves service port.
Leave the valve on the charge set closed.
Connect the charge hose with the push pin to the service port.
3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge
indicates 0.05 to 0.1 Mpa.
If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is
higher than 0.1Mpa, discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If this is the
case, it will not be necessary to apply a evacuation.
Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be
discharged.

27

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.8

Evacuation

Procedure:
1. Connect the vacuum pump to the charge sets centre hose.
2. Evacuation for approximately one hour.
Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less].
3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the
gauge needle does not move (approximately 5 minutes after turning off the vacuum pump).
4. Disconnect the charge hose from the vacuum pump.
Vacuum pump oil, if the vacuum pump oil becomes dirty or depleted, replenish as needle.

28

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

8.9

Gas charging

Procedure:
1. Connect the charge hose to the charging cylinder.
Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom
of the cylinder.
2. Purge the air from the charge hose.
Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the
air (be careful of the liquid refrigerant).
3. Open the valves (Low side) on the charge set and charge the system with liquid refrigerant.
If the system cannot be charge with the specified amount of refrigerant, if can be charged with a little
at a time (approximately 150g each time0 while operating the air conditioner in the cooling cycle;
however, one time is not sufficient, wait approximately 1 minute and then repeat the
procedure.(pumping down-pin).
4. Immediately disconnect the charge hose from the 3-way valves service port.
Stopping partway will allow the refrigerant to be discharged.
If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the
air conditioner before disconnecting the hose.
5. Mounted the valve stem caps and the service port
Use torque wrench to tighten the service port cap to a torque of 18N.m.
Be sure to check for gas leakage.

29

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

9.

Pressure table

Note:
The pressure data is from 3 way valve, the pressure data are pressure above atmosphere.
D: Dry bulb temp.
W: Wet bulb temp.

9.1 MSH-18HRIN1

Cooling mode
Indoor Conditions

Outdoor temperature (Dry bulb temp)


Pressure

25C 30C 35C 40C 45C 50C

21C D15C W Pressure( kg/cm2 ) 6.6

6.8

7.0

7.3

7.6

8.0

7.0

7.1

7.7

8.3

8.7

27C D19C W Pressure( kg/cm ) 7.1

7.2

7.3

7.8

8.6

9.3

32C D23C W Pressure( kg/cm2 ) 7.1

7.4

7.6

8.4

9.4

9.8

24C D17C W Pressure( kg/cm ) 6.8

Heating mode

Outdoor temperature (Dry bulb temp)

Indoor Conditions
15C
18C

12C D 7C D 0C D -4C D -7C D -15C D


11C W 6C W -1C W -6C W -9C W -xC W

Pressure

Pressure( kg/cm2 ) 32.5

34.5

34.0

31.0

28.5

27.5

34.5

35.5

32.5

29.5

28.0

Pressure( kg/cm ) 35.0

20C

Pressure( kg/cm ) 36.5

35.5

36.0

33.5

30.0

28.5

22C

Pressure( kg/cm2 ) 36.5

37.0

36.5

35.0

32.5

29.5

9.2 MSC-18HRIN1
Cooling mode
Indoor Conditions

Outdoor temperature (Dry bulb temp)


Pressure

25C 30C 35C 40C 45C 50C

21C D15C W Pressure( kg/cm2 ) 6.6

6.8

7.0

7.3

7.6

8.0

7.0

7.1

7.7

8.3

8.7

7.2

7.3

7.8

8.6

9.3

7.4

7.6

8.4

9.4

9.8

24C D17C W Pressure( kg/cm ) 6.8


27C D19C W Pressure( kg/cm ) 7.1
32C D23C W Pressure( kg/cm ) 7.1
Heating mode
Indoor Conditions

Outdoor temperature (Dry bulb temp)


12C D 7C D 0C D -4C D -7C D -15C D
11C W 6C W -1C W -6C W -9C W -xC W

Pressure

15C

Pressure( kg/cm2 ) 32.5

34.5

34.0

31.0

28.5

27.5

18C

Pressure( kg/cm2 ) 35.0

20C
22C

34.5

35.5

32.5

29.5

28.0

35.5

36.0

33.5

30.0

28.5

37.0

36.5

35.0

32.5

29.5

Pressure( kg/cm ) 36.5


Pressure( kg/cm ) 36.5

30

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

10. Capacity table


10.1
MSH-18HRIN1
OUTDOOR TEMPERATURE DRY

COOLING
Indoor
Conditions

21C D
15C W

24C D
17C W

27C D
19C W

32C D
23C W

21C

25C

30C

35C

40C

45C

50C

Total capacity kW

3.513

3.903

4.550

4.849

4.177

3.251

2.333

Sensitive capacity kW

2.635

2.927

3.413

3.738

3.133

2.438

1.749

Input kW.

0.696

1.050

1.607

2.163

1.976

1.810

1.654

Total capacity kW

4.071

4.30

4.938

5.268

4.08

3.625

2.667

Sensitive capacity kW

3.052

3.322

3.703

4.051

3.381

2.719

2.000

Input kW.

0.731

1.183

1.621

2.106

2.012

1.851

1.680

Total capacity kW

4.362

4.921

5.205

5.287

5.024

4.213

3.271

Sensitive capacity kW

3.287

3.690

3.958

4.110

3.768

3.160

2.461

Input kW.

0.721

1.196

1.647

1.700

2.077

1.902

1.700

Total capacity kW

4.931

5.409

6.092

6.319

5.613

4.782

3.500

Sensitive capacity kW

3.698

4.056

4.569

4.839

4.207

3.586

Input kW.

0.704

1.206

1.755

2.213

2.118

1.962

2.625
1.720

HEATING
24C
D
18C
W

Indoor
Conditions
15C
18C
20C
22C
27C

OUTDOOR CONDITIONS
12C
D
11C
W

7C D
6C
W

4C D
3C
W

0C D
-1C
W

-5C D
-6C
W

-7C D
-8C
W

-15C
D
-16C
W

Capacity kW

7.355

7.108

6.663

6.208

5.265

4.621

4.428

3.482

Input kW.

1.691

1.883

1.850

2.271

2.406

2.283

2.135

2.026

Capacity kW

7.310

7.021

6.582

6.133

5.255

4.689

4.507

3.638

Input kW.

1.780

1.947

1.875

2.571

2.730

2.81

2.378

2.180

Capacity kW

7.280

6.897

5.987

5.802

5.394

4.740

4.563

3.744

Input kW.

1.860

2.073

1.898

2.650

3.082

2.810

2.550

2.313

Capacity kW

7.241

6.821

5.947

5.750

5.400

4.768

4.592

3.738

Input kW.

1.993

2.231

2.173

2.700

2.980

2.693

2.487

2.308

Capacity kW

7.103

6.667

5.969

5.883

5.418

4.807

4.671

3.714

Input kW.

2.106

2.312

2.422

2.691

2.892

2.611

2.458

2.306

31

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

10.2

MSC-18HRIN1

COOLING

OUTDOOR TEMPERATURE DRY

Indoor
Conditions

21C D
15C W

24C D
17C W

27C D
19C W

32C D
23C W

21C

25C

30C

35C

40C

45C

50C

Total capacity kW

3.513

3.903

4.550

4.849

4.177

3.251

2.333

Sensitive capacity kW

2.635

2.927

3.413

3.738

3.133

2.438

1.749

Input kW.

0.696

1.050

1.607

2.163

1.976

1.810

1.654

Total capacity kW

4.071

4.30

4.938

5.268

4.08

3.625

2.667

Sensitive capacity kW

3.052

3.322

3.703

4.051

3.381

2.719

2.000

Input kW.

0.731

1.183

1.621

2.106

2.012

1.851

1.680

Total capacity kW

4.362

4.921

5.205

5.287

5.024

4.213

3.271

Sensitive capacity kW

3.287

3.690

3.958

4.110

3.768

3.160

2.461

Input kW.

0.721

1.196

1.647

1.700

2.077

1.902

1.700

Total capacity kW

4.931

5.409

6.092

6.319

5.613

4.782

Sensitive capacity kW

3.698

4.056

4.569

4.839

4.207

3.586

Input kW.

0.704

1.206

1.755

2.213

2.118

1.962

3.500
2.625
1.720

HEATING
24C
D
18C
W

Indoor
Conditions
15C
18C
20C
22C
27C

OUTDOOR CONDITIONS
12C
D
11C
W

7C D
6C
W

4C D
3C
W

0C D
-1C
W

-5C D
-6C
W

-7C D
-8C
W

-15C
D
-16C
W

Capacity kW

7.355

7.108

6.663

6.208

5.265

4.621

4.428

3.482

Input kW.

1.691

1.883

1.850

2.271

2.406

2.283

2.135

2.026

Capacity kW

7.310

7.021

6.582

6.133

5.255

4.689

4.507

3.638

Input kW.

1.780

1.947

1.875

2.571

2.730

2.81

2.378

2.180

Capacity kW

7.280

6.897

5.987

5.802

5.394

4.740

4.563

3.744

Input kW.

1.860

2.073

1.898

2.650

3.082

2.810

2.550

2.313

Capacity kW

7.241

6.821

5.947

5.750

5.400

4.768

4.592

3.738

Input kW.

1.993

2.231

2.173

2.700

2.980

2.693

2.487

2.308

Capacity kW

7.103

6.667

5.969

5.883

5.418

4.807

4.671

3.714

Input kW.

2.106

2.312

2.422

2.691

2.892

2.611

2.458

2.306

32

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

10.3

MSG-09HRI

SUMMER Cooling mode


Indoor
Conditions
21C D
Total capacity kW
15C W
Sensitive capacity kW
Input kW.
24C D
Total capacity kW
17C W
Sensitive capacity kW
Input kW.
27C D
Total capacity kW
19C W
Sensitive capacity kW
Input kW.
32C D
Total capacity kW
23C W
Sensitive capacity kW
Input kW.
WINTER
Indoor
Conditions
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.

15C
18C
20C
22C

10.4

WINTER
Indoor
Conditions

18C
20C
22C

25C

30C

35C

40C

45C

50C

2.50
1.82
0.86
2.71
1.99
0.88
2.88
2.19
0.91
3.21
2.47
0.95

2.35
1.75
0.90
2.58
1.93
0.93
2.75
2.12
0.96
3.08
2.40
1.00

2.17
1.64
0.94
2.42
1.84
0.97
2.60
2.03
1.00
2.98
2.34
1.04

2.00
1.52
1.02
2.28
1.75
1.05
2.46
1.93
1.08
2.77
2.19
1.12

1.87
1.43
1.13
2.13
1.64
1.16
2.29
1.80
1.20
2.53
2.02
1.25

1.73
1.34
1.17
1.96
1.52
1.20
2.11
1.67
1.24
2.38
1.93
1.29

0C D
-1C W
2.44
0.82
2.35
0.84
2.29
0.86
2.26
0.90

-4C D
-6C W
2.10
0.72
1.99
0.74
1.89
0.76
1.85
0.81

-7C D
-8C W
1.84
0.65
1.73
0.66
1.56
0.70
1.54
0.72

OUTDOOR CONDITIONS
12C D
7C D
4C D
11C W
6C W
3C W
3.46
3.03
2.78
1.05
0.96
0.89
3.39
2.98
2.71
1.08
0.97
0.90
2.93
2.68
3.36
0.98
1.11
0.93
3.33
2.90
2.64
1.15
0.99
0.95

MSG-12HRI

SUMMER Cooling mode


Indoor
Conditions
21C D
Total capacity kW
15C W
Sensitive capacity kW
Input kW.
24C D
Total capacity kW
17C W
Sensitive capacity kW
Input kW.
27C D
Total capacity kW
19C W
Sensitive capacity kW
Input kW.
32C D
Total capacity kW
23C W
Sensitive capacity kW
Input kW.

15C

OUTDOOR TEMPERATURE DRY

Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.

OUTDOOR TEMPERATURE DRY


25C

30C

35C

40C

45C

50C

3.36
2.46
1.05
3.64
2.68
1.09
3.88
2.95
1.12
4.32
3.33
1.16

3.16
2.36
1.11
3.48
2.59
1.15
3.71
2.85
1.18
4.14
3.23
1.23

2.93
2.21
1.16
3.25
2.47
1.19
3.50
2.73
1.23
4.01
3.15
1.28

2.69
2.05
1.25
3.07
2.35
1.29
3.31
2.60
1.33
3.73
2.94
1.38

2.52
1.92
1.39
2.86
2.21
1.43
3.08
2.43
1.48
3.41
2.73
1.54

2.33
1.80
1.43
2.64
2.05
1.48
2.84
2.25
1.53
3.21
2.60
1.59

0C D
-1C W
3.17
1.08
3.06
1.11
2.98
1.14
2.94
1.18

-4C D
-6C W
2.73
0.94
2.59
0.97
2.45
1.00
2.41
1.06

-7C D
-8C W
2.40
0.86
2.25
0.87
2.03
0.92
2.00
0.95

OUTDOOR CONDITIONS
12C D
7C D
4C D
11C W
6C W
3C W
4.50
3.94
3.61
1.38
1.26
1.17
4.41
3.87
3.52
1.42
1.28
1.19
3.81
4.37
3.48
1.29
1.46
1.23
4.33
3.77
3.43
1.51
1.30
1.24

33

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

10.5

MSG-21HRI

SUMMER Cooling mode


Indoor
Conditions
21C D
Total capacity kW
15C W
Sensitive capacity kW
Input kW.
24C D
Total capacity kW
17C W
Sensitive capacity kW
Input kW.
27C D
Total capacity kW
19C W
Sensitive capacity kW
Input kW.
32C D
Total capacity kW
23C W
Sensitive capacity kW
Input kW.
WINTER
Indoor
Conditions
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.

15C
18C
20C
22C

10.6

WINTER
Indoor
Conditions

18C
20C
22C

25C

30C

35C

40C

45C

50C

5.92
4.32
1.97
6.41
4.71
2.03
6.83
5.19
2.09
7.60
5.85
2.18

5.56
4.15
2.08
6.12
4.56
2.14
6.52
5.02
2.21
7.29
5.69
2.30

5.15
3.89
2.16
5.72
4.35
2.23
6.16
4.80
2.30
7.05
5.54
2.39

4.74
3.60
2.33
5.41
4.14
2.41
5.82
4.57
2.48
6.56
5.18
2.58

4.43
3.38
2.59
5.04
3.88
2.68
5.43
4.28
2.76
6.00
4.80
2.87

4.11
3.16
2.68
4.65
3.60
2.77
5.00
3.95
2.85
5.65
4.58
2.97

0C D
-1C W
5.73
2.01
5.52
2.07
5.39
2.11
5.31
2.19

-4C D
-6C W
4.93
1.76
4.68
1.81
4.43
1.86
4.35
1.98

-7C D
-8C W
4.33
1.59
4.05
1.62
3.67
1.70
3.61
1.77

OUTDOOR CONDITIONS
12C D
7C D
4C D
11C W
6C W
3C W
8.12
7.12
6.52
2.58
2.34
2.18
7.97
6.99
6.36
2.64
2.38
2.21
6.88
6.29
7.90
2.40
2.72
2.28
7.82
6.80
6.19
2.81
2.42
2.31

MSG-24HRI

SUMMER Cooling mode


Indoor
Conditions
21C D
Total capacity kW
15C W
Sensitive capacity kW
Input kW.
24C D
Total capacity kW
17C W
Sensitive capacity kW
Input kW.
27C D
Total capacity kW
19C W
Sensitive capacity kW
Input kW.
32C D
Total capacity kW
23C W
Sensitive capacity kW
Input kW.

15C

OUTDOOR TEMPERATURE DRY

Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.
Capacity kW
Input kW.

OUTDOOR TEMPERATURE DRY


25C

30C

35C

40C

45C

50C

6.76
4.93
2.35
7.31
5.38
2.43
7.79
5.92
2.50
8.68
6.68
2.60

6.35
4.74
2.48
6.99
5.21
2.56
7.44
5.73
2.64
8.32
6.49
2.75

5.88
4.44
2.59
6.53
4.96
2.67
7.03
5.48
2.75
8.05
6.32
2.86

5.41
4.11
2.79
6.17
4.72
2.88
6.64
5.22
2.97
7.49
5.91
3.09

5.05
3.86
3.10
5.75
4.43
3.20
6.19
4.88
3.30
6.84
5.47
3.43

4.69
3.61
3.21
5.30
4.11
3.31
5.71
4.51
3.41
6.45
5.22
3.55

0C D
-1C W
6.58
2.31
6.35
2.37
6.19
2.42
6.10
2.51

-4C D
-6C W
5.67
2.01
5.38
2.07
5.09
2.13
5.01
2.27

-7C D
-8C W
4.98
1.83
4.66
1.85
4.22
1.95
4.15
2.03

OUTDOOR CONDITIONS
12C D
7C D
4C D
11C W
6C W
3C W
9.33
8.19
7.50
2.95
2.68
2.50
9.16
8.04
7.31
3.03
2.73
2.53
7.91
9.08
7.23
2.75
3.11
2.61
9.00
7.82
7.12
3.22
2.78
2.65

34

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

11. Electronic function


11.1. Display board

11.1.1. AUTO indicator


This indicator illuminates when the air conditioner is in AUTO operation.
11.1.2. TIMER indicator
This indicator illuminates when TIMER is set ON/OFF.
11.1.3. PRE.-DEF. Indicator (For Cooling & Heating models only)
This indicator illuminates when the air conditioner starts defrosting automatically or when the warm
air control feature is activated in heating mode.
11.1.4. TEMPERATURE indicator
Usually it displays the temperature settings. When change the setting temperature, this indicator
begins to flash, and stops 20 seconds later.
It displays the room temperature when the air conditioner is in FAN only operation.
When the unit stops operation, it returns to original factory settings.
Displays the malfunction code or protection code.
11.1.5. OPERATION indicator
This indicator flashes after power is on and illuminates when the unit is in operation.
11.1.6. FREQUENCY indicator
This indicator appears only when the compressor is in operation and indicates the current operating
frequency.

11.2. Protection

11.2.1. 3 minutes delay at restart for compressor.


11.2.2. Temperature protection of compressor top, compressor stops when the temp. of top of
compressor is more than 115, compressor runs when the temp. of top of compressor is less than
100.
11.2.3. Voltage protection, unit stop when the voltage is more than 260V and less than 175V.
11.2.4. Inverter module Protection, Inverter module Protection itself has a protection function against
current, voltage and temperature.
11.2.5. Sensor protection at open circuit and breaking disconnection
11.2.6. Fan Speed is out of control. When Indoor Fan Speed is too high(higher than 2100RPM)or too
low(lower than 300RPM), the unit stops and LED displays failure information and cant return to
normal operation automatically.
11.2.7. Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops
and LED displays failure information and cant return to normal operation automatically.

11.3. Fan-only mode


Fan speed is high/mid/low/ Auto

11.4. Cooling mode

11.4.1. The 4-way valve is closed at cooling mode.


11.4.2. The action of the compressor and the outdoor fan:
Condition
Compressor
T=Indoor Temp.
Room temp. up
Room temp. down

T> Ts+1
T<Ts+1
T> Ts
T<Ts

On
Off
On
Off

35

PDF "pdfFactory Pro" www.fineprint.cn

Outdoor fan
On
Off
On
Off

Service manual

11.4.3 Auto fan at cooling mode:


Condition
Indoor fan speed
T=Indoor Temp.-Setting Temp.
Room temp. up
T<1.5
Low
1.5<T<4
Mid.
T>4
High
Room temp. down
T> 3
High
1<T<3
Mid.
T<1
Low
11.4.4 Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )
Evaporator Temp. Compressor
0<T< 4
T< 0

Decrease frequency of compressor


Off

11.4.5 Current protection


Current up

Current down

Model

Current

Compressor

MSH-18HRIN1

I>18 A

Off

14.5A<I<18A

Decrease frequency of
compressor
On
Off
Decrease frequency of
compressor
On

MSH-18HRIN1

I< 12.0A
I>17.5 A
14.0A<I<17.5A

I< 11.5A
11.4.6 Rated capacity test
Set mode to cooling mode
Set temp. to 17C
Set fan speed to high speed
Push turbo button 5 times in 10 seconds.
Using special remoter controller
After 5 hours, cancel rated capacity test
Turbo function
Increasing frequency of compressor
After operating 30 minutes, return automatically to the mode and temp. previously selected.

11.5. Dehumidifying mode

11.5.1 The 4-way valve is off


11.5.2 the indoor fan is fixed in breeze speed
11.5.3 Compressor run in low frequency
11.5.4 Low room temperature protection:
11.5.5 When room temperature decreases to below 10, compressor and outdoor fan will stop
(indoor fan is Breeze). Dehumidifying operation will be resumed when room temperature restores to
over 12.
11.5.6 At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as
that of cooling mode.

11.6. Heating mode

11.6.1. Generally, the 4-way valve is open at heating mode, but it is closed at defrosting. 4-way valve
must delay 2 minutes compared with compressor if the compressor changed into non-heating mode
or turned off. 4-way valve doesn't delay in dehumidifying mode.
11.6.2. Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode,
except for the defrosting mode or the end of defrost.
11.6.3. Action of compressor and outdoor fan motor at heating mode: compressor must run for 7
minutes after starting and then judge temperature. Meanwhile other protections are still valid.
36

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

Condition

Compressor

Outdoor fan

Room temp. up

T> Ts+3
Off
Off
T<Ts+3
On
On
Room temp. down
T< Ts+2
On
On
T>Ts+2
Off
Off
11.6.4. Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind function
prevails.
Anti-cold wind control function at heating mode
Condition T= Indoor exchanger temp. Indoor fan speed
Indoor exchanger temp. up

T<34
34<T<37

Off
Breeze

37<T<44

Low speed

T>44
Setting fan speed
Indoor exchanger temp. down T> 38
Setting fan speed
33<T<38
Low sped
24<T<33
Breeze
T<24
Off
When the indoor temp. gets to setting temp, indoor changes to breeze speed immediately, after 127
second, indoor fan stop.
11.6.5. Auto wind at heating mode
Condition (T=Indoor Temp.-Setting Temp.) Indoor fan speed
Room temp. up

T<1.5
1.5<T<2.5
T>2.5
Room temp. down T<1.0
1.0<T<2.0
T>2.0
11.6.6. Indoor evaporator high-temperature protection at heating mode
Condition (T= Indoor exchanger temp.) Compressor

High
Med.
Low
High
Med.
Low

T<48
53<T<63
T>63
11.6.7. The current protection
Model

Current

Compressor

Current up

18000btu/h

I>19.0 A

Off

18000btu/h

15.0.A<I<19.0A
I< 12.5A
I>18.5 A
14.5A<I<18.5A
I< 12.0A

Decrease frequency of compressor


On
Off
Decrease frequency of compressor
On

Current down

11.6.8. The temp. compensation


Jump setting in indoor PCB
J2
On

On
Decrease frequency of compressor
Off

On

Off

Off

J3

On

Off

On

Off

-4

-2

37

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

11.7. Defrosting operation (Available for heating only).


11.7.1 Defrosting condition:
11.7.1.1.
When outdoor temp. is more than 0,
Defrosting starts when meeting one of the following conditions,
a. The temperature of outdoor heat exchanger remains consecutively lower than 3c for more
than 40 minutes, and the temperature remains consecutively -4c for more than 3 minutes,
b. The temperature of outdoor heat exchanger remains consecutively lower than 3c for more
than 80 minutes, and the temperature remains consecutively -2c for more than 3 minutes
11.7.1.2.
When outdoor temp. is less than 0,
Defrosting starts when meeting one of the following conditions,
a. The temperature of outdoor heat exchanger remains consecutively lower than 3c for more
than 40 minutes, and the temperature remains consecutively -6c for more than 3 minutes,
b. The temperature of outdoor heat exchanger remains consecutively lower than 3c for more
than 40 minutes, and the temperature remains consecutively -6c for more than 3 minutes,
c. The temperature of indoor unit pipe decreases 5c than before
11.7.1.3.
The temperature of outdoor heat exchanger remains consecutively lower than 3c for more
than 120 minutes, and the temperature remains consecutively -2c for more than 3 minutes
11.7.2 Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
a. The defrost time has reached to 10 minutes.
b. When the temperature of outdoor heat exchanger rises up to 8C and this continues for more than 80
seconds.
c. When the temperature of outdoor heat exchanger rises up to 12C
11.7.3 Defrosting Actions:
max. 10 minutes
60s
ON
10s
30s
Com.
OFF
ON
ON
4 way valve
OFF
ON
ON
Outdoor fan
OFF
ON
ON
Indoor fan
OFF
Breeze 10 seconds, then stop

11.7.4 Rated capacity test


Set mode to cooling mode
Set temp. to 30 C
Set fan speed to high speed
Push turbo button 5 times in 10 seconds.
Using special remoter controller
After 5 hours, cancel rated capacity test

11.8. Outdoor low temperature protection (optional)


Factory standard unit has not this function.
Unit stops when outdoor temp. is low than -15C and lasting time more than 60 minutes, and unit runs
again when outdoor temp. more than -12C.
When indoor PCB J1 jump is on, this function is available.

11.9. Automatic operation mode

The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
38

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

only according to the temp. difference between room temp. (TA) and set temp. (TS).
TATS
Operation mode
TATS>2
Cooling
-1TA-TS+2
Fan-only
TA-TS<-1
Heating (air-only for cooling only type)

11.10. Manual switch


11.10.1
Mode changes when push this button .
Cooing mode Auto modeUnit off Cooing mode
11.10.2
At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the A/C
operates with a setting temp. of 24.
11.10.3
At auto mode, the A/C operates with a set temp. of 24

11.11. Timer Function


11.11.1
The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes.
11.11.2
Timer on: first turn off the A/C, the A/C will be automatically on at the set time.
11.11.3
Timer off: first turn on the A/C, the A/C will be automatically off at the set time
11.11.4
Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be
automatically on at set time, and later be off at the set time, then unit turns on at set time.
11.11.5
Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be
automatically off at set time, and later be on at the set time, then unit turns off at set time.

11.12. Sleep mode

11.12.1
It is available at cooling, heating or auto mode.
11.12.2
Cooling:
The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a constant
and the fan speed is kept at low speed.
11.12.3
Heating:
The set temperature decrease 1 per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Cold air proof function takes precedence over all).
11.12.4
Auto:
The Sleep Mode running function operates in accordance with selected running mode by auto mode.
11.12.5
After 7 hours, unit cancels this modes automatically.

11.13. Auto restart function

In case of a sudden power failure, this function automatically sets the unit to previous settings before the
power failure when power returns.

11.14. Turbo function

The indoor fan will work in super high speed, the frequency of compressor will increase, the max run
time is 30 minutes. After 30 minutes, the unit will work in previous setting.

11.15. Plasma

Plasma turns on when the indoor fan runs.


Plasma turns off automatically when front panel is opened.
Plasma is optional function.

39

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

12. Model and Parameters


Model
RACFAN
RAHFAN
RATIFC
RATIFH
SLEEPTIMC
FANCSHIGH
FANHSHIGH
FANCHIGH
FANHHIGH
FANMID
FANLOW
FANSLOW
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
I1COOL
I2COOL
I3COOL
I1HEAT
I2HEAT
I3HEAT
TCDI
TCDE1
TCDE2
TEL2
TEH2
ANGLSTART
ANGLOFF
ANGLHEATMAX
ANGLHEAT
ANGLHEATMIN
ANGLSMALL
ANGLCOOLMAX
ANGLCOOL
ANGLCOOLMIN
PDELAYCOUNT
V1
V2

MSH-18HRDN1
1180
1180
59
57
7
1180
1180
1180
1180
1100
980
900
42
47
52
55
58
64
70
76
82
88
12
14.5
18
12.5
15
19
-6
20
12
26
53
190
115
13
20
48
115
186
175
160
127
F6
F3

MSC-18HRDN1
1140
1140
59
57
7
1180
1180
1140
1140
1060
980
900
42
47
52
55
58
64
70
76
82
88
12
14.5
18
12.5
15
19
-6
20
12
24
53
0
141
11
34
51
77
85
68
56
127
F6
F3

40

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

Model

MSE-09HRDN1

MSE-12HRDN1

flag0
MacType
RatiFC
RatiFH
SleepTim
FanCSHigh
FanHSHigh
FanCHigh
FanHHigh
FanMid
FanLow
FanSlow
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
I1Cool
I2Cool
I3Cool
I1Heat
I2Heat
I3Heat
TCDI
TCDE1
RACFAN
RAHFAN
TEL1
TEH2
ANGLSTART

00
05
66
76
7
1300
1300
1250
1250
1100
880
800
34
38
44
59
63
66
73
76
95
105
7.0
8.0
10.5
8.5
10.0
12.0
-9
20
1250
1250
24
53
200

00
05
82
92
7
1250
1250
1180
1180
1100
850
750
33
47
57
62
72
82
88
92
103
107
8.5
10.0
12
10.5
12.0
13.5
-9
20
1180
1180
24
53
193

ANGLOFF
ANGLHEATMAX

110
18

101
11

ANGLHEAT

27

17

ANGLHEATMIN

53

51

TEL2

33

33

ANGLCOOLMAX

186

180

ANGLCOOL

183

176

ANGLCOOLMIN

160

155

PDELAYCOUNT

127

127

TEL5

36

36

TEL6

40

40

TCDE2

PARASUM
41

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

13.
Troubleshooting
13.1 Indoor Unit Error Display
Display

LED STATUS

E0

EEPROM error

E1

Indoor / outdoor units communication protection

E2

Zero-crossing examination error

E3

Fan speed beyond control

E5

Open or short circuit of outdoor temperature sensor

E6

Room temperature or evaporator temperature sensor open or short circuit of

P0

Module protection

P1

Over voltage or too low voltage protection

P2

Compressor top protection against temperature

P3

Outdoor low temp. protection

P4

Inverter compressor drive error

Note: E4: Reserved function


13.1.1
Display

LED STATUS

E0

EEPROM parameter error

Circuit or software error on indoor control board

Replace the control board of indoor

13.1.2 circuit or software error on indoor cortrol board


Display

LED STATUS

E1

Indoor / outdoor units communication protection

42

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual
Disconnect the power supply, after 1 minutes, connect the power supply , turn on the
unit using remote controller, does the unit work normally ?
NO
Is the connection on outdoor control board and
between indoor and outdoor unit good? Does the L
Does the led on outdoor control board bright?

N connect good? Does the S wire connect reliably?


YES
YES

NO
Is the voltage on terminal CZ1 and CZ2 of the outdoor main PCB is 5V?

No
Is the voltage between P and

Replace the module board.(The

Yes

power supply of PCB is supplied

N on inverter module 380V?

by the module board.)

No

NO
Replace the outdoor power
supply board.

Replace the outdoor main


PCB

13.1.3
Display
E2

LED STATUS
Zero-crossing examination error
Is power supply right?
Yes

Is connector connection good?


Yes
Indoor PCB is defective

Replace the indoor control board.

13.1.4
Display
E3

LED STATUS
Fan speed beyond control

43

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual
Is connector connection good?
No

Yes
Is voltage being applied to the fan motor?
(rang 90v-160v between mid pin and N on CN1

Repair the connector.

No

Yes
Indoor fan motor is defective

Indoor PCB is defective

Replace indoor fan motor.


Replace indoor main PCB.

13.1.5
Display
E5

LED STATUS
Open or short circuit of outdoor temperature sensor

Is connection to connector good?

Yes

No

Replace the sensor

Repair connector

If display E5 all the same, replace indoor main PCB.

13.1.6
Display

LED STATUS

E6

Room temperature or evaporator temperature sensor open or short circuit

Is connection to connector good?

yes

No

Replace the sensor


Repair connector

If display E6 all the same, replace outdoor main PCB.

13.1.7
Display
P0

LED STATUS
Module protection

44

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

Is connection to connector good?

No
Yes

Repair connector

Is the wires to compressor right?

Yes
Check the voltage between P and N on inverter

No

module. Is it about 380V?

Test the outdoor power supply board again.

Yes
Check the inverter module, If some component

Yes

cracked or damaged?

No

Inverter module damaged, replace it.

Is it breakdown between P-N,P-U,P-V;N-W,N-U,N-V

No

At inverter module

No
Check compressor

Yes
Inverter module is defective

13.1.8
Display
P1

LED STATUS
Over voltage or too low voltage protection

Is the power supply right?


Yes
Check the outdoor power board

Replace outdoor main PCB.

13.1.9
Display
P2

Off: 115C;

LED STATUS
Compressor top protection against temperature

On: 100C

45

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual
Does compressor operate?
Yes

No
Is the connection good?
No

Is refrigerant circulation volume normal?


No

Yes

Connect and test again.

Is protector normal?

Gas charging

No
Yes
Replace protector

Is abnormality the same after gas charging


No

Check the outdoor main PCB

Check refrigerant system (such as clogging of


capillary, etc)
Replace the outdoor main PCB.

13.1.10
Display
P3

LED STATUS
Outdoor low temp. protection

This is optional, factory standard unit has not this function.


Unit stops when outdoor temp. is low than -15C and lasting time more than 60 minutes, and unit
runs again when outdoor temp. more than -12C.
Is the outdoor temp. low than -15C?
No
Is the outdoor temp sensor right according to the table in clause 12
Yes
Replace the outdoor main board

46

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

13.2 Diagnostic chart


After energizing, no indicator is lighted and the air conditioner cant be operated.

47

PDF "pdfFactory Pro" www.fineprint.cn

Service manual

13.3 Resetting phenomenon often occurs during operation


(That is automatically entering to the status when power is on.)
The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the
following procedure:
Resetting phenomenon often occurs during operation.

Yes

After changing indoor PCB, check if the failure realease.

Yes

Yes

Indoor PCB is defective.

After changing indoor fan motor, check if the failure realease.

YES

Power supply circuit has problems.

13.4 Operation lamp flashes and Timer lamp off

13.5 Operation lamp flashes and Timer lamp on

48

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

13.6 Operation lamp off and Timer lamp flashes

13.7 Operation lamp on and Timer lamp flashes


EEROM error, indoor PCB is defective.

13.8 Operation lamp flashes, Timer lamp flashes

This is alarm signal when the main chip cant detect over-zero signal. When such failure occurs, the
main control board must have fault.

49

PDF "pdfFactory Pro"


www.fineprint.cn

Service manual

14

Characteristic of temperature sensor


Temp.
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Resistance K
62.2756
58.7079
56.3694
52.2438
49.3161
46.5725
44
41.5878
39.8239
37.1988
35.2024
33.3269
31.5635
29.9058
28.3459
26.8778
25.4954
24.1932
22.5662
21.8094
20.7184
19.6891
18.7177
17.8005
16.9341
16.1156
15.3418

Temp.
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Resistance K
14.6181
13.918
13.2631
12.6431
12.0561
11.5
10.9731
10.4736
10
9.5507
9.1245
8.7198
8.3357
7.9708
7.6241
7.2946
6.9814
6.6835
6.4002
6.1306
5.8736
5.6296
5.3969
5.1752
4.9639
4.7625
4.5705

Temp.
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

50

PDF "pdfFactory Pro" www.fineprint.cn

Resistance K
4.3874
4.2126
4.0459
3.8867
3.7348
3.5896
3.451
3.3185
3.1918
3.0707
2.959
2.8442
2.7382
2.6368
2.5397
2.4468
2.3577
2.2725
2.1907
2.1124
2.0373
1.9653
1.8963
1.830
1.7665
1.7055
1.6469

Anda mungkin juga menyukai