Anda di halaman 1dari 22

ARD 2010.

05

Readme for Advanced Road Design 2010.05


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.05.

Installation Instructions
Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009/2010 will be used - there has been no change to the licensing system.

General
This Install includes all the fixes and enhancements from all previous Advanced Road Design 2010 releases.

Resolved Issues
This installation resolves a number of bugs & issues, including: ARD Roads Using a blank entry for the right side of a Fixed Batter will now omit the batter from the model. Previously leaving the right entry blank would cause the software to crash The selected sections for Volume Reports are now used to generate the volume report when the Trim Intersection is NOT selected. Previously the volume report was always generated using all sections, irrespective of the option selected when the command was run. Cross Section Plotting: o The Crossfall annotation options of NS and NS & Design now work as expected. Previously using either of these options would result in no crossfall annotation on the cross sections. o All the Masking Options now work as expected. Previously using any of these options would result in no masking of any elements on the cross section. This command will only mask a model added to the cross section using Section By Featureline option. Long Section Plotting: o The Cut/Fill volumes now calculate correctly when Selected Section spacing is used. Previously the volumes displayed at a section was calculated based on All Sections and may display incorrect values when Selected Sections was used. o The Cut/Fill Volumes now calculate using the bulking factors as defined in the Design Data form for the road. Previously they were always calculated based on the solid mass values. In some situations an Alignment could be found at multiple instances when a kerb return was located and caused the kerb return not to create. This has been fixed and in these situations the kerb return will create as expected.

ARD 2010.05

ARD Pipes The software now sums all bypasses applied to a pit. Previously the software incorrectly summed multiple bypass applied to a pit. The Vertical Grading Editor (VGE) will now open when a network that has been created with zero length pipes. Previously when a network containing zero length pipes was opened into the VGE, the software would crash.

Known Issues
The following is a list of known issues with the software ARD Pipes VGE o o o

The slope displayed in the VGE may display a rounding error. This error in display on the VGE does not affect the plotting or reports. The Pipe ID displayed is the automatic number assigned by the software, even if the pipes have been otherwise named. The software may crash if you have or have had two or more VGE windows open displaying the same network and delete a pit along a pipe common to both VGE windows.

ARD Roads The Display Surface Model as 3D Faces command can yield incorrect triangulation at selected locations, normally expressed by the ignoring of breaklines in the intersections. You may be able to correct this issue by applying additional sampling.

ARD 2010.04

Readme for Advanced Road Design 2010.04


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.04.

Installation Instructions
Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009/2010 will be used - there has been no change to the licensing system.

General
This Install includes all the fixes and enhancements from all previous Advanced Road Design 2010 releases.

Updated Commands
The following commands have been updated: ARD Pipes Trench Volumes This command has been updated to additionally create a CSV format version of Trench Volume report. The CSV file is named DrVolsCSV.csv and is located in the ADVRoads sub-directory in the Data folder for the project. Various Commands - Assigning Layers The layer name for any command requiring a layer to be selected can be entered directly. If the layer exists the software will use it, otherwise it will be created. The created layer will be white with a continuous linetype.

Resolved Issues
This installation resolves a number of bugs & issues, including: Network Licensing Running an ARD Pipes command after running an ARD Roads command (or vice versa) no longer consumes a second license when running the software on Window Vista or Windows 7 workstation. Previously the software would use two licenses when ARD Roads and ARD Pipes were run on a workstation using Windows Vista or Windows 7. Standalone installations were not affected. ARD Pipes A pit located off the design surface will no longer cause a crash. Previously the software may crash or generate an error if the pit was off the design surface.

ARD 2010.04

The trench volume command now calculates the volumes correctly with regard to box sections. Previously the trench width and cross section area were incorrectly determined when a box section was specified. The trench volume command now takes into account multiple pipes correctly. Previously multiple pipes where not considered. When inserting or deleting a pit in one VGE window and the same section of network is shown another open VGE window(s), the pit is correctly inserted in all open VGE windows. Previously the software would not show the pit on the second or subsequent VGE windows until they were closed and re-opened. When deleting a pit in the VGE window and the pit is the downstream outlet, at a branch junction or the top of a branch, the software will no longer allow the pit to be deleted.

ARD Roads The Curved T cul-de-sac now correctly calculates the approach road width correctly. Previously the approaching road width was determined at the start of the incoming road.

Known Issues
The following is a list of known issues with the software ARD Pipes VGE o o o

The slope displayed in the VGE may display a rounding error. This error in display on the VGE does not affect the plotting or reports. The Pipe ID displayed is the automatic number assigned by the software, even if the pipes have been otherwise named. The software may crash if you have or have had two or more VGE windows open displaying the same network and delete a pit along a pipe common to both VGE windows.

ARD Roads The Display Surface Model as 3D Faces command can yield incorrect triangulation at selected locations, normally expressed by the ignoring of breaklines in the intersections. You may be able to correct this issue by applying additional sampling.

ARD 2010.03

Readme for Advanced Road Design 2010.03


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.03.

Installation Instructions
Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009/2010 will be used - there has been no change to the licensing system.

General
This Install includes all the fixes and enhancements from all previous Advanced Road Design 2010 releases.

Core Functionality Changes


Ribbon Ribbon tabs for the Roads, ARD Pipes and ARD General menus have been created. These tabs include all the commands from the menus laid out over various ribbon panels. The menus and toolbars are still included with the software.

Appendix 1 is a detailed list of the ARD commands (listed in menu order) indicating the equivalent command location(s) on the new ribbon tabs

Commands Added
The following commands have been added to the software: ARD Pipes Plot Long Section Intermediate Data This command allows you to add Chainage, Invert Level, Existing Surface Level, Design Surface Level and/or Depth to Invert values to you long section at a nominated spacing.

ARD 2010.03

Updated Commands
The following commands have been updated: ARD Pipes Create/Update Network This command has been updated to allow the pipes sizes to be locked at the time of creation of the network. This only applies to drainage networks. Categorise Items New Items The following new items have been added to the Plotting/Reporting items list: o Pit Road Grade % (P70) reports the road longitudinal grade when pit attached to a road. IMPORTANT NOTE: This install will overwrite the Category List (ARDPipePlotItems.txt found in the Common Folder) as part of the installation process. Please backup this file prior to installing this update and restore afterwards to maintain your custom category list. It is the users responsibility to ensure that the new items listed above are included in your custom Category List. Branch Sequence This command has been updated to allow for user defined starting numbers of the line/branch numbers. Please refer to the help system for more information. Plot Long Section General Settings This command has been updated to allow for the line/branch chainages to start at chainage 0. General Report Table Settings This command has been updated to allow for the line/branch chainages to start at chainage 0. The line/branch direction can also be set. ARD Roads Cross Section Plotting Section Annotation This command has been updated to include arrows in the cross section output when the cross sections are annotated. The style of the arrow is controlled from the Miscellaneous tab in the Active Drawing Sections.

Resolved Issues
This installation resolves a number of bugs & issues, including: ARD Pipes The pit position when connected to a road can now be outside the extents of the road (beyond the batter). Previously the pit could only be positioned within the extents of the road at the chainage it was attached to. The software will now insert/delete a pit in the VGE correctly. Previously an error could occur when the same pipe the pit was being inserted/deleted on was shown in multiple VGEs. The software will issue a warning that a Pipe ID is missing in the Pipe Table if the Pipe ID has been renamed/deleted. Previously an error would occur if a Pipe ID was in use in the project and it was deleted/renamed in the Pipe Tables in the Active Network Settings. The software has been adjusted to calculate the flows for the subareas of a catchment. In the rational method used in ARR, the process is to compute the fraction impervious (from grassed and paved areas) and then compute the TOTAL

ARD 2010.03

flow form the entire catchment. This process DOES NOT permit the calculation of flows from individual subareas. Thus, to compute the individual flows to pipes and gutters, the software uses the following approach: o assume C for Paved areas as 0.9 x Runoff Coefficient Frequency Factor o compute C for the Grassed areas using the ARR formula, with fraction impervious = 0. o use these C Factors to compute the flows for every subcatchment, keeping track of the 4 different types of flow: Paved to Pipe (say 10) Grassed to Pipe (say 15) Paved to Gutter (say 20) Grassed to Gutter (say 30) o add up these 4 flows and check against the total flow for the catchment. Invariably, these numbers are not the same, so they are then adjusted linearly so that their sum equals the total computed flow. Using the numbers above, the total computed flow from the subareas is 75. If the computed flow was 60, then all the numbers would be multiplied by 60/75, to make sure that the total from the individual areas adds to the total computed using CIA. ARD Roads The subgrade figures in Cross Section plotting now display as expected. Previously the figures where not plotted on the cross section even when the option was ticked on.

Known Issues
The following is a list of known issues with the software ARD Pipes VGE o o o

The slope displayed in the VGE may display a rounding error. This error in display on the VGE does not affect the plotting or reports. The Pipe ID displayed is the automatic number assigned by the software, even if the pipes have been otherwise named If you have two VGE windows open displaying the same network and insert a pit along a pipe common to both VGE windows, the inserted pit will not be displayed in the second VGE window. You must close and reopen the second window to show the inserted pipe. If you try to edit original pipe in the second VGE window you will create an error message no pits will be inserted and no edits made will be saved.

ARD Roads The Display Surface Model as 3D Faces command can yield incorrect triangulation at selected locations, normally expressed by the ignoring of breaklines in the intersections. You may be able to correct this issue by applying additional sampling.

ARD 2010.03

Appendix 1 Where is My Command


The Advanced Road Design interface now includes ribbon tabs and panels for the Roads, ARD Pipes and ARD General menus. These tables have been developed to assist in locating a command on the ARD 2010 ribbon. There are 3 tables, one for each of the menus. The commands have been listed in menu order and the ribbon location(s) and icon are listed to the right. In the case where more than one ribbon location exists, all locations have been listed. Roads Menu Help Settings Flyout Create/Edit Section Template Create/Edit Multi Section Batters Active Drawings Settings Set Road Defaults Global Drawing Settings Select Sections to Plot Edit Plotting Layers Extend Long Section Plot Create/Edit Cross Section Labels Edit Plot Plan Feature Line Settings Edit 3D Face Mapping File Object Selection Flyout Select and Open the Vertical Grading Editor Vertical Grading Editor Select and Open the Design Data Form Design Data Form Create/Edit Road Create String/Profile Create/Edit Kerb Return Create/Edit Cul-de-sac Create/Edit Knuckle Create Roundabout Auto Creation Tools Flyout Roads Tab Templates Panel Create/Edit Section Roads Tab Templates Panel Templates Drop-down Create/Edit Multi Section Batter Roads Tab Settings Panel Active Drawing Roads Tab Design Panel Create/Edit Road Dropdown Set Road Defaults Roads Tab Settings Panel Settings Drop-down Global Drawing Settings Roads Tab Plan Production Panel Selected Sections Roads Tab Plan Production Panel Slideout Edit Plotting Layers Roads Tab Plan Production Panel Long Section Drop-down Extend Long Section Roads Tab Plan Production Panel Slideout Create/Edit Cross Section Labels Superseded command Roads Tab Modelling Panel Slideout Edit 3D Face Mapping File Roads Tab Select Panel Select and Open Vertical Grading Editor Roads Tab Select Panel Vertical Grading Editor Roads Tab Select Panel Design Data Form Roads Tab Select Panel Design Data Form Roads Tab Design Panel Create/Edit Road Roads Tab Design Panel String/Profile Roads Tab Design Panel Kerb Return Roads Tab Design Panel Cul-de-sac Roads Tab Design Panel Knuckle Roads Tab Design Panel Roundabout Ribbon Roads Tab Help Panel Help or General Tab Help Panel Roads Icon

ARD 2010.03

Roads Menu Auto Road Creation Auto Kerb Returns Compute & Apply Superelevation Create/Edit Road Matching Model Create/Edit Off Ramp Edit Flyout Update All Road Objects Resample Road Cross Sections Automatic Ease Properties Kerb Design Controls Nominate Side Road Rename Road/String Change Alignment Description to Road Use Other Road Chainages Check Road Alignment Tangency Delete Road Object Undelete Road Object Setout Plot Cross Sections Plot Long Sections Civil 3D Output Flyout Auto Create Corridor Create/Update Civil 3D Profiles Apply Intersection Match-In Plot Corridor Cross Sections Auto Model Auto Model Datum Model Manager Display Surface Model as 3D Faces Plot Plan of Road Plot Slope Pattern Generate 3D Polylines Reports Flyout

Ribbon Roads Tab Design Panel Create/Edit Road Dropdown Auto Road Creation Roads Tab Design Panel Kerb Return Drop-down Auto Kerb Returns Roads Tab Design Panel Superelevation Roads Tab Modelling Panel Create/Edit Road Matching Model Roads Tab Design Panel Off Ramp

Icon

Roads Tab Edit Panel Update All Road Objects Roads Tab Edit Panel Resample Cross Sections Roads Tab Edit Panel Automatic Ease Properties Roads Tab Edit Panel Kerb Design Controls Roads Tab Edit Panel Nominate Side Road Roads Tab Edit Panel Rename Road/String Roads Tab Edit Panel Change Alignment Description to Road Roads Tab Edit Panel Use Other Road Chainages Roads Tab Utilities Panel Check Road Alignment Tangency Roads Tab Edit Panel Delete Road Object Roads Tab Edit Panel Undelete Road Object Roads Tab Plan Production Panel Setout Roads Tab Plan Production Panel Cross Sections Roads Tab Plan Production Panel Long Section

Roads Tab Modelling Panel Auto Create Corridor Roads Tab Design Panel Civil 3D Profiles Roads Tab Design Panel Intersection Match-In Roads Tab Plan Production Panel Cross Sections Drop-down Plot Corridor Cross Sections Roads Tab Modelling Panel Auto Model Roads Tab Modelling Panel Modelling Drop-down Auto Model Datum Roads Tab Modelling Panel Model Manager Roads Tab Modelling Panel Display Surface Model as 3D Faces Roads Tab Plan Production Panel Plan of Road Roads Tab Plan Production Panel Slope Pattern Roads Tab Modelling Panel Generate 3D Polylines

ARD 2010.03

Roads Menu Volume Cross Section Co-ordinates Cross Section Listing Vertical Curve Listing Vertical Curve at Chainages Strings Kerb Return Details Selected Sections Design Constraints Data Checking Chainage Shift Listing Print Error Report Legacy Flyout Create/Edit SubGrades and Datums Create/Edit Super Table Draw Bus/Parking Bay Alignments Level Book Entry Utilities Flyout Export V5 Data Read in V5 Data Read in Romanian Alignments Export GENIO Export TotalModel XML Setout Arc Clean Up Reset Cross Section Plot Reset Long Section Plot Reset the Vertical Grading Editor Add CADApps Catalog Re-Compute All Roads Re-Display Vertical Grading Editor

Ribbon Roads Tab Reports Panel Volume Roads Tab Reports Panel Cross Section Drop-down Cross Section Co-ordinates Report Roads Tab Reports Panel Cross Section Drop-down Cross Section Listing Report Roads Tab Reports Panel Vertical Curve Drop-down Vertical Curve Listing Report Roads Tab Reports Panel Vertical Curve Drop-down Vertical Curve at Chainages Report Roads Tab Reports Panel Strings Report Roads Tab Reports Panel Kerb Return Details Report Roads Tab Reports Panel Selected Sections Report Roads Tab Reports Panel Design Constraints Report Roads Tab Reports Panel Data Checking Report Roads Tab Reports Panel Chainage Shift Listing Report Roads Tab Reports Panel Print Error Report Roads Tab Legacy Panel Create/Edit SubGrades and Datums Roads Tab Design Panel Slideout Create/Edit Super Table Roads Tab Legacy Panel Draw Bus/Parking Bay Alignments Roads Tab Legacy Panel Level Book Entry Roads Tab Utilities Panel Slideout Export V5 Data Roads Tab Utilities Panel Slideout Read in V5 Data Roads Tab Utilities Panel Read in Romanian Alignments Roads Tab Utilities Panel Export GENIO Roads Tab Modelling Panel Export TotalModel XML Roads Tab Plan Production Panel Setout Arc Roads Tab Utilities Panel Clean Up Roads Tab Plan Production Panel Slideout Reset Cross Section Plot Roads Tab Plan Production Panel Slideout Reset Long Section Plot Roads Tab Utilities Panel Slideout Reset the Vertical Grading Editor Roads Tab Utilities Panel Slideout Add CADApps Catalog Roads Tab Edit Panel Update All Road Objects Roads Tab Utilities Panel Slideout Re-Display Vertical Grading Editor

Icon

ARD 2010.03

ARD Pipes Menu Help Settings Flyout Active Network Settings Global Network Settings Edit Layer Settings Create ARR Rainfall Data Edit Network Labelling Styles Categorise Items Edit Watercom Drains Pit Conversion Table Edit Watercom Drains Pipe Conversion Table Create Drainage Flyout Pipes/Pits Catchment Area Pit Inflows Pit Bypass Create Sewer Flyout Pipes/Pits House Offsets House Corner Levels House Connection Polylines House Connection Edit House Connection Details Create Service Flyout Pipes/Pits with Levels Pipes/Pits Create/Update Network Branch Sequence Network Labelling Settings Highlight Network Highlight Orphaned Pipes/Pits Edit Flyout Move Pit Move Pit Onto Existing Pit Insert Pit Delete Pit Delete Pit and Connect Pipe on Network

Ribbon Pipes Tab Help Panel Help or General Tab Help Panel Pipes Pipes Tab Settings Panel Active Network Pipes Tab Settings Panel Settings Drop-down Global Network Settings Pipes Tab Settings Panel Slideout Edit Layer Settings Pipes Tab Settings Panel Slideout Create ARR Rainfall Data Pipes Tab Network Panel Slideout Edit Network Labelling Styles Pipes Tab Settings Panel Slideout Categorise Items Pipes Tab Data Exchange Slideout Edit Watercom Drains Pit Conversion Table Pipes Tab Data Exchange Slideout Edit Watercom Drains Pipe Conversion Table Pipes Tab Drainage Design Panel Drainage Pipes/Pits Pipes Tab Drainage Design Panel Catchment Area Pipes Tab Drainage Design Panel Pit Inflows Pipes Tab Drainage Design Panel Pit Bypass Pipes Tab Sewer Design Panel Sewer Pipes/Pits Pipes Tab Sewer Design Panel House Offsets Pipes Tab Sewer Design Panel Levels Pipes Tab Sewer Design Panel House Connection Polylines Pipes Tab Sewer Design Panel House Connection Pipes Tab Sewer Design Panel Edit Pipes Tab Service Design Panel Service Pipes/Pits with Levels Pipes Tab Service Design Panel Service Drop-down Service Pipes/Pits Pipes Tab Network Panel Create Network Pipes Tab Network Panel Branch Sequence Pipes Tab Network Panel Network Labelling Settings Pipes Tab Network Panel Highlight Network Pipes Tab Network Panel Highlight Orphaned Pipes/Pits Pipes Tab Edit Panel Move Pit Pipes Tab Edit Panel Move Pit Onto Existing Pit Pipes Tab Edit Panel Insert Pit Pipes Tab Edit Panel Delete Pit Pipes Tab Edit Panel Delete Pit and Connect Pipe on Network

Icon

ARD 2010.03

ARD Pipes Menu Edit Pit Properties Renumber/Rename Pits Delete Pipe Edit Pipe Properties Renumber/Rename Pipes Set Pipe Radius Set Pipe Backfill Lengths Delete Pipe Backfill Lengths Switch Branch Between Networks Delete Branch on Network Delete Network Vertical Grading Editor Label Network Label Sewer House Connection Plot Long Section Reports Flyout General Clash Detection Trench Volumes Sewer House Connections Redraw Networks Audit Project Data Exchange Flyout Export to Watercom Drains Export to PC Drains Import from Watercom Drains

Ribbon Pipes Tab Edit Panel Edit Pit Properties Pipes Tab Edit Panel Renumber/Rename Pits Pipes Tab Edit Panel Delete Pipe Pipes Tab Edit Panel Edit Pipe Properties Pipes Tab Edit Panel Renumber/Rename Pipes Pipes Tab Edit Panel Set Pipe Radius Pipes Tab Edit Panel Set Pipe Backfill Lengths Pipes Tab Edit Panel Delete Pipe Backfill Lengths Pipes Tab Edit Panel Switch Branch Between Networks Pipes Tab Edit Panel Delete Branch on Network Pipes Tab Edit Panel Delete Network Pipes Tab Edit Panel VGE Pipes Tab Plan Production Panel Label Network Pipes Tab Plan Production Panel Label House Connection Pipes Tab Plan Production Panel Plot Long Section Pipes Tab Reports Panel General Pipes Tab Reports Panel Clash Detection Report Pipes Tab Reports Panel Trench Volumes Report Pipes Tab Reports Panel Sewer House Connections Report Pipes Tab Network Panel Redraw Networks Pipes Tab Network Panel Audit Project Pipes Tab Data Exchange Panel Export to Watercom Drains Pipes Tab Data Exchange Panel Export to PC Drains Pipes Tab Data Exchange Panel Import from Watercom Drains

Icon

ARD 2010.03

ARD General Menu Help Flyout General Roads Pipes

Ribbon General Tab Help Panel General Roads Tab Help Panel Help or General Tab Help Panel Roads Pipes Tab Help Panel Help or General Tab Help Panel Pipes Roads Tab Help Panel Help Drop-down Open Tutorial Folder or Pipes Tab Help Panel Help Drop-down Open Tutorial Folder or General Tab Help Panel Open Tutorial Folder General Tab Utilities Panel Stop Software General Tab System Settings Panel Open Settings Folder General Tab System Settings Panel Set Settings Path General Tab Project Admin Panel Show Data Path General Tab Project Admin Panel Set Data Path General Tab Project Admin Panel Reset Data Path General Tab System Settings Panel Edit Titleblock Settings General Tab System Settings Panel Edit Fonts List General Tab Utilities Panel ARD Layer Manager General Tab Utilities Panel ARD Website General Tab Utilities Panel Check for Updates General Tab Utilities Panel Technical Support General Tab Utilities Panel Version Details

Icon

Open Tutorial Folder

Stop Software Settings Path Flyout Open Settings Folder Set Settings Folder Data Path Flyout Show Data Path Set Data Path Reset Data Path Edit Titleblock Settings Edit Fonts List ARD Layer Manager ARD Website Check for Updates Technical Support Version Details

ARD 2010.02

Readme for Advanced Road Design 2010.02


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.02.

Installation Instructions
Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009 will be used - there has been no change to the licensing system.

General
This Install includes all the fixes and enhancements from all previous Advanced Road Design 2010 releases.

Core Functionality Changes


ARD Pipes Pit Properties There has been a change to the software with regard to determining the surface for the Top of Pit Level and Hydraulic Design Levels. The software will assign the surface as defined in the Active Network Settings when a pit is first created. If this surface is deleted or renamed, then the software will use the surface as per the Active Network Settings. The surface listed in the properties will NOT be updated even though it may be using a different surface for either of these properties. Active Network Settings The software will constantly check for the existence of the Design surface defined on the General > Defaults tab in the Active Network Settings. If this surface doesnt exist, an error message will be displayed and the user will be directed to assign a different surface from the drawing. Bottom of Pit Level: By default, the Bottom of Pit Level is defined as the Depth from Downstream Pipe Invert. Previously the default value as defined as Depth from Downstream Pipe Bottom (Invert + Wall Thickness) Pipe Downsizing Drainage Networks This is a new toggle option, allowing the user to prevent automatic downsizing of pipes By default, pipe downsizing is disabled in the settings to emulate the current behaviour of the software Creating House Connections Depth Checks have been included in the House Connection Types (Active Network settings) a warning message will display when a House Connection is created until depth check values and included for the applied House Connection Type

ARD 2010.02

Commands Added
The following commands have been added to the software: ARD Pipes Edit Sewer House Connection Details This command allows you to edit the Lot Number, Area, Boundary Offset and Connection Type for a selected house connection. Label Sewer House Connections This command labels all sewer house connections in plan with the invert level of the house connection at the outlet to the sewer pipe as well as the distance of the house connection from next the downstream pit Highlight Network This command highlights and zooms and/or pans the selected network (either from pick or list) in the drawing Highlight Orphaned Pipes/Pits This command highlights all pipes and pits that are NOT part of a network. Each pipe/pit type (drainage, sewer, house connection, service) is highlighted in a different colour. Vertical Grading Editor Match Pipe Obverts This command allows the user to select the upstream or downstream end of a pipe. Once selected, the pipe end will raise/lower to match the obvert of the next pipe. Note: The Minimum Drop requirement is controlled for the inlet pipe at a pit. If an outlet pipe at a pit is set to match obverts and the inlet pipe is being automatically controlled by the software, it will adjust to maintain the minimum pit drop.

Updated Commands
The following commands have been updated: ARD Pipes Active Network Settings o House Connection Types now includes: a Description field has been included. This can be reported at the time of plotting sewer long sections Design Checks have been included to establish minimum and maximum depth and drop values warning messages will be displayed when these values are not achieved, and drop/depth violations are identified in the House Connection Report. o Sewer Design Tables Tab A new tab called House Connection Types has been included. This table allows you to establish house connection labels based on the depth of the house connection. This can be included in the Text notation for House Connections represented on a Sewer Long Section plot. VGE o The Max/Min drops at a pit are now displayed for both the upstream and downstream ends of the highlighted pipe o The Depth to Invert is now displayed for the upstream and downstream end of the pipe, measured from top of pit to invert of downstream pipe The Network Labelling Settings command now allows you to set an initial starting pit number for the network. The Edit Network Labelling Styles command now allows you to include the Chainage as part of the style name

ARD 2010.02

Resolved Issues
This installation resolves a number of bugs & issues, including: ARD Pipes A critical issue with the Create/Edit Catchment command has been resolved. Previously the Fraction Impervious value was applied to determine the Pervious area when the Catchment Calculation Method was set to Total Area and Fraction Impervious. This will impact an previously created catchment of this type. The Label Network command now labels the pipe sizes correctly Long Section Plotting o The Plot to File option now outputs as expected each sheet is created as a separate file. o Using the Plot to Layout command for a Drainage Network no longer deletes the layouts outputted for a different drainage network Vertical Grading Editor o Pipe cover was being incorrectly calculated from the design surface to the pipe obvert. Pipe cover is now correctly calculated and applied using the outside edge of the pipe as defined in the Pipe Table. o The HGL now updates correctly when a pit is deleted o The HGL now updates correctly when a Pit Loss Coefficient is set/adjusted for a pit o In certain circumstances using the Set/Clear Lock Status on All Pipes command could result in an error. This issue appears to have been resolved o Clash detection was being determined for the pipes currently being edited in the VGE only (and not accounting for the crossing pipe). Now the clash detection will activate based on the clearances of EITHER the crossing or longitudinal pipe clearance being violated In the Active Network Settings>Sewer>Design Tables>Junction Pit Drop tabs the image displaying the maximum angle calculation was incorrect. This has been rectified. If the pipe properties were edited using the Edit Pipe command, the Label Network command would not label the pipe correctly until the VGE had been opened or closed. This has been fixed There was an issue with a number of the sorting options in the Reports Manager not sorting the pits as expected. This issue has been resolved. The Label Network command now reports the slope as a number only previously the command automatically appended a prefix of 1:. The user needs to use the Prefix/Suffix to add text before/after this number. The Clash Detection report now uses the assigned pit and pipe numbers/labels The Branch Sequencing command previously required the DOT linetype to be included in the drawing. This requirement has been removed An issue with zero pipe lengths being created has been resolved Previously it was possible to apply a pit simultaneously to more than one network, which led to calculation errors. When a new network is created, the software now checks to ensure that no pit is already part of another network. ARD Roads Slope patterns now plot at either equal intervals or sampled road chainages. Previously slope patterns would be inserted at all sampled road chainages only. An issue calculating the second layer of a multi-layered pavement section in the Template Editor has been resolved. Previously, when the second layer of the pavement was set to extend out to the design the vertical calculation of the layer at the design intercept was being incorrectly calculated. The Heading Controls in cross section plotting now functions as expected. Previously the control was not used and was not able to be edited. Note that any previously added control will need to be deleted and re-added after this update has been installed.

ARD 2010.02

The Datum surface creation can now be made in a project that does not contain kerb returns. Previously if not kerb returns existed, the datum surface could not be created. The batter settings for a kerb return now update when the kerb return alignment is altered using the Kerb Return command. Previously once the batters for a kerb return were initially created, the software never updated them. An issue with creating setout for a single chainage has been resolved. Previously the setout values were incorrect when only one chainage was setout. The Model Manager surface combining Roads and Strings now creates as expected. Previously the string(s) where not included in the model When the Auto Model model is included in a Model Manager model, the software will now ask if the Automatic Trimming should be applied. The Automatic Trimming will trim the roads at the intersections, kerb returns, cul-de-sacs & knuckles like the surface created using the Auto Model command. If the trimming is not applied, the strings at these locations will overlap.

Known Issues
The following is a list of known issues with the software ARD Pipes VGE o o o

The slope displayed in the VGE may display a rounding error. This error in display on the VGE does not affect the plotting or reports. The Pipe ID displayed is the automatic number assigned by the software, even if the pipes have been otherwise named If you have two VGE windows open displaying the same network and insert a pit along a pipe common to both VGE windows, the inserted pit will not be displayed in the second VGE window. You must close and reopen the second window to show the inserted pipe. If you try to edit original pipe in the second VGE window you will create an error message no pits will be inserted and no edits made will be saved.

ARD Roads The Display Surface Model as 3D Faces command can yield incorrect triangulation at selected locations, normally expressed by the ignoring of breaklines in the intersections. You may be able to correct this issue by applying additional sampling.

ARD 2010.01

Readme for Advanced Road Design 2010.01


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.01.

Installation Instructions
New Installation: Follow the instructions on the CD and the Installation and Licensing Guide found on the install CD. Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
New Installations: You will need to authorise the software, please refer to the Installation and Licensing Guide for more information. Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009 will be used - there has been no change to the licensing system.

General
This Install CD includes all the fixes and enhancements from all previous Advanced Road Design 2010 releases.

Core Functionality Changes


A whole new enhanced pipe design module called ARD Pipes has been added to the software. The existing Drainage and Sewer modules are still included in the software but the menus may need to be added to your workspace. The key features of ARD Pipes are: Enhanced user interface including wizard based forms to streamline your design processes. Supports multiple dynamic vertical grading of pipe networks including a model tracker. Crossing pipes shown dynamically in each vertical grading window for instant clash detections. Comprehensive creation and editing tools to layout and edit your pipe networks. Full control over pit levels with dynamic attachment to any ARD road Totally configurable reports and long section plotting controls.

Commands Added
The following commands have been added to the software: Open Tutorial Folder This command opens the folder containing the ARD tutorial files in Windows Explorer. The tutorials files are located in the following locations (depending on operating system): o XP:- C:\Documents and Settings\All Users\Application Data\CADApps\ARD\Tutorials\2010 o Vista:- C:\ProgramData\ CADApps\ARD\Tutorials\2010

ARD 2010.01

Resolved Issues
This installation resolves a number of bugs & issues, including: An error with the Copy Codes variation has been fixed. Previously in some cases the results were not as expected Crossing pipes objects now show on cross section and long section plots as ellipses depending on the vertical exaggeration applied. Previously in some cases the pipes were shown as circular irrespective of the vertical exaggeration. The issue of display of the ARD Super Subassembly in the drawing has been resolved. Previously the ARD Super Subassembly did not display properly and errors were reported in the Event Viewer. This fix is irrespective of whether or not Service Pack 1 has been installed. The issue of the Civil 3D Corridor created from the ARD Roads reporting multiple error messages in the Event Viewer upon creation/update has been resolved. Previously when the Corridor was created/updated multiple error messages were reported in the Event Viewer. This fix is irrespective of whether or not Service Pack 1 has been installed.

Known Issues
The following is a list of known issues with the software The volume report trimming feature may include volume for sections of the road beyond the start/end of the cul-de-sac alignment. If Split Datum is applied any Hatching applied to the long section is not adjusted to match the datum split(s). When you create a kerb return and use the Auto option for the creation of the cross sections, the software applies a Batter Override using the slope value as specified in the Active Drawing Settings and using the start/end chainage of the alignment at the time of creation. If you subsequently extend the kerb alignment the Batter Override entry will not be updated this will result in a section of the kerb return to be without batter slopes applied. You will need to adjust the Batter Override controls in the kerb returns design data form to edit the end chainage for the batters if you extend the kerb alignment after creation Conditionally Delete Sections o The LBAT or RBAT codes CANNOT be used as the Code Existing to Trigger Variation The Add CADApps Catalog, Set Common Folder and Set Data Path commands can be restricted on VISTA operating systems due to the Vista security protocols. As a workaround you can adjust the Vista permissions and user controls to enable these changes. The CADApps Subassembly catalog can be manually created by running (double clicking on) the ATC-2010.reg file (or ATC-2010PLK.reg for Polish customers) from the Common folder (start the command ARD General Settings Path - Open Settings Folder to view the common folder) Some Variations are exclusive after they are applied they are not overridden or adjusted by subsequent variations. The operations affected by this include: o Set Code Offsets/Levels to match Surface o Insert Section and Match Code Levels to Surface Use the Move Up and Move Down buttons to re-order these commands as required. If you run the Roads module prior to running the Sewer module you may get a Runtime Error when trying to set the location. If this occurs shut down Civil 3D and restart the Sewer module before you run the Roads module.

ARD 2010.00

Readme for Advanced Road Design 2010.00


This readme contains important information regarding the installation and use of the Advanced Road Design 2010.00.

Installation Instructions
New Installation: Follow the instructions on the CD and the Installation and Licensing Guide found on the install CD. Upgrade/Update: This installation is a new version of Advanced Road Design, version 2010 for AutoCAD Civil 3D 2010. You do not need to uninstall any previous versions of Advanced Road Design. The installation will use the common folder from previously installed ARD 2009 installation.

Licensing
New Installations: You will need to authorise the software, please refer to the Installation and Licensing Guide for more information. Upgrade/Update: The existing licensing from a previously installed ARD 2008/2009 will be used - there has been no changes to the licensing system.

Core Functionality Changes


Menus A new menu ARD General has been created. This menu contains all commands common to all modules of Advanced Road Design. Most of the commands have been moved from the previous Roads menu.

ARD 2010.00

Toolbars The Roads toolbars have been reorganised and a new toolbar has been created for the ARD General commands. Now there is one main toolbar for both Roads and ARD General with most other commands available directly or via flyouts as shown: Roads:

ARD General:

Help The help system has been enhanced to include all the commands from the new ARD General menu and toolbar. The ARD General help can be opened by running the command ARD General => Help => General or clicking icon. Hovering over a particular icon on the toolbar then pressing F1 will also open the help for that specific command.

Commands Added
The following commands have been added to the software: Technical Support o This command connects you to the CADApps support login webpage to lodge a technical support request. An active internet connection is required.

Updated Commands
The following commands have been updated: Reports => Volumes o This command has been enhanced to include Save and Load settings functionality. The Save & Load buttons can be used to save and restore the settings used for volume calculations. Design Data Form => Cross Section Viewer o This function has been enhanced to include the option to display the depths rather than the Template Codes.

ARD 2010.00

Resolved Issues
This installation resolves a number of bugs, including: An error with calculations for the Reference Line Compute VC from Existing Data command has been fixed. Previously in some cases the results were not as expected.

Known Issues
The following is a list of known issues with the software The volume report trimming feature may include volume for sections of the road beyond the start/end of the cul-de-sac alignment. If Split Datum is applied any Hatching applied to the long section is not adjusted to match the datum split(s). When you create a kerb return and use the Auto option for the creation of the cross sections, the software applies a Batter Override using the slope value as specified in the Active Drawing Settings and using the start/end chainage of the alignment at the time of creation. If you subsequently extend the kerb alignment the Batter Override entry will not be updated this will result in a section of the kerb return to be without batter slopes applied. You will need to adjust the Batter Override controls in the kerb returns design data form to edit the end chainage for the batters if you extend the kerb alignment after creation Conditionally Delete Sections o The LBAT or RBAT codes CANNOT be used as the Code Existing to Trigger Variation The Add CADApps Catalog, Set Common Folder and Set Data Path commands can be restricted on VISTA operating systems due to the Vista security protocols. As a workaround you can adjust the Vista permissions and user controls to enable these changes. The CADApps Subassembly catalog can be manually created by running (double clicking on) the ATC-2010.reg file (or ATC-2010PLK.reg for Polish customers) from the Common folder (start the command ARD General Settings Path - Open Settings Folder to view the common folder) Some Variations are exclusive after they are applied they are not overridden or adjusted by subsequent variations. The operations affected by this include: o Set Code Offsets/Levels to match Surface o Insert Section and Match Code Levels to Surface Use the Move Up and Move Down buttons to re-order these commands as required. If you run the Roads module prior to running the Sewer module you may get a Runtime Error when trying to set the location. If this occurs shut down Civil 3D and restart the Sewer module before you run the Roads module. When you insert the ARD Super Subassembly into an Assembly it will not display correctly and several warnings will appear in the Event Viewer if you are not running AutoCAD Civil 3D 2010 Update 1 or later. The subassembly will function as expected and the corridor will build as per normal. Installing AutoCAD Civil 3D 2010 Update 1 will resolve this issue. When creating the Civil 3D Corridor of the Road model, error messages will be displayed in the Event Viewer. This will not impact on the quality of the Corridor model, it will build as expected. However due to the large number of error messages, the built time may be slower then expected. Installing AutoCAD Civil 3D 2010 Update 1 will resolve this issue.