Anda di halaman 1dari 2

Nama : Muhammad Qurhanul Rizqie NIM : 23211041 Kuliah : EL-5100 (Teknik Biomedika)

TUGAS I 1. List five important keywords, in either English or Bahasa Indonesia, to define Biomedical Engineering: Multidisciplinary field, Problem solving, Medical information, Medical procedure, Health care improvement 2. Write a definition of Biomedical Engineering, in either English or Bahasa Indonesia, based on the above keywords: Biomedical Engineering is a multidisciplinary field that make use of engineering, science and technology method for biology and medical problem solving, such as, medical information processing, medical procedure support, and life quality and society health care improvement. 3. List five important different steps of the medical procedure (prosedur kedokteran) in either English or Bahasa Indonesia: Information gathering, Data analysis, Diagnosis, Therapy, Evaluation 4. At which step(s) of the medical procedure, can each biomedical instrument listed below be used? a laser surgical unit can be used in : Therapy an electrocardiograph can be used in : Information gathering, Diagnosis, and Evaluation a defibrillator can be used in : Therapy an external artificial pancreas can be used in : Therapy an audiometer can be used in : Information gathering, Diagnosis, and Evaluation 5. Circle three instrument from the list below, that can be used to support diagnosis [stethoscope, electronic blood pressure monitor, electro surgical unit, lithotripter, non-invasive oxygen saturation monitor, implanted defibrillator] 6. Circle three instrument from the list below, that can be used to support therapy [stethoscope, electronic blood pressure monitor, electro surgical unit, lithotripter, non-invasive oxygen saturation monitor, implanted defibrillator] 7. List five different types of medical information, list two examples for each type Alphanumeric Data : Patient record, Lab test record Medical Image : USG image, X-Ray image Physiological Signal : ECG, EKG Audio Information : Audio record of patient-doctor conversation, Heart sound record Combination of different types : Complete medical record, Medical information system database

8. The battery capacity of a pacemaker is 4.8 ampere-hours at voltage of 2.5 volts. Compute the total energy of the battery in joules. W = I 2 RT = VIT = 2.5 * 4.8 * 3600 = 43200 Joules
F 9. A voltage source V1 of 30 volts at 50 Hz is applied to 300 capacitor C in series with a resistor R (R = 30 ohm). Find the magnitude of V 2 at R, and the phase difference between V 2 and V1 .

I = V j R 2 fC = 3 0 0 j 3 0 2 5 ) 3 0 x1 ( 0 ( 0 0 =
6

3 0 0 3 j1 .6 0 0 2

= 3 0
2

3 0 0

(0 2 + 1 .6

)2 rc n a ta

1 2 0 .6 0 3

I =

30 ( 0 19 .49 ) =1.07 19 .49 27 .88

V2 = IR = (1.07 19 .49 )( 30 ) = 46 .2V V2 V1 = 46 .2 30 = 16 .2V

10. A typical signal generator of 200 mV at 3000Hz is connected across two resistors in series, R1 = 398 k and R2 = 2 k The voltage across R2 is then applied to the . input of a voltage follower amplifier (implemented using an ideal operational amplifier); a resistor R3 = 3 kis connected to the amplifier output. Draw the circuit diagram, and compute the current flows through R3.

V R 2 = IR 2 = V R 2 =V R 3 i3 =

V 200 x10 3 R2 = x 2 x10 3 = 1x10 3 V R1 + R2 400 x10 3

VR3 10 3 = = 0,33 x10 6 A 3 R3 3 x10

Anda mungkin juga menyukai