Figure 1
Where opportunity presented itself, the ArchSD also proudly took on the challenge of adopting alternative structural system. The Tsing Yi Municipal Services Building, for one, differentiates from its peers with its cabled-stayed roof system that transfers roof loads to four central masts through tension rods. To cope with their inability to take on compression loads, the cable-stayed system also consisted of a concrete slab and steel decking on top of the steel truss on one side to resist wind uplift.
Concrete Slab with Steel Decking Steel Mast Roof Truss Tension Rod
Materials in Large-span Structures While structural steel has its appeal in strength, the industrys ample experience in handling it, and
relative environmental friendliness given its recyclability, creativity and innovation also came in with the use of non-structural steel materials. An example which earned much accolades is the Museum of Coastal Defence, which has a tensioned fabric roof structure. This proves to be a perfect choice for such a facility as it allows some penetration of sunlight, creating an ambience of openness and saving electricity, but not so much as to lose its function of providing shade to visitors. Situated at a high point of a hilly site, the fabric roof also has the major mission to combat wind uplift. This is assisted by an intricate anchorage structure, comprising tension cables, central masts, peripheral tripods and minipiles as the foundation system.
Figure 3
While some decisions were made with excellent acumen, some were less so. In the design of of Hammer Hill Road Sports Ground, reinforced concrete folded plates were used in the cantilever roof structure. Given its bulkiness, however, a solid concrete slab had to be used as counter-balance, and this added to the already heavy dead load and necessitated the use of large foundations. Though structurally sound, it was deemed not so environmental friendly in terms of the material and equipment needed in the process of construction. However, from the viewpoint of lesson learning, this would make an invaluable episode in the knowledge database.
Figure 4
Safety Issues with Large-span Structures The pride of a large-span structure lies in its magnificent outlook and complexity in its design and construction. A major issue is always the safe installation of steel trusses. Where site conditions permitted, ArchSD has opted for alternative construction sequence to minimize the risk. This was demonstrated in the erection of the Hong Kong Coliseum, where the roof was assembled on the ground and lifted in position by four hydraulic jacks. This method removed the need of truss assembly at height and thus the risk of fall, while also putting forth the bonus of being environmental friendly as it required no scaffolding and working platforms. Where lifting and assembly at height of steels trusses were inevitable, ArchSD has also formulated measures to ensure maximum safety. This included the stipulation of a comprehensive lifting plan and risk assessment, of briefing sessions on lifting operation and tool-box talks on relevant safety aspects. Upon project completion, there were also post-construction evaluations to make sure the performance would be yet better when the need for another large-span structure came around. Conclusion It is not hard to figure out why large-span structure is a lure. The grandiose outlook elicits praise from even the layman, while the challenges and intricacies bring forth immense self-gratification in the ones who design and construct it. The major significance is that such grandeur or complexities are not consequences of overly big egos, but that of practical needs, which the Architectural Services Department has been tackling in the past twenty years with humbleness and diligence. It can certainly rest assured that citizens of Hong Kong would look upon their work and see that they are good.
To commemorate the 20th Anniversary of Architectural Services Department, a technical seminar and a technical visit were held on 23 August and 26 August respectively. These activities were organised by the Department, jointly with Building Division, Structural Division and Young Members Committee of the Hong Kong Institution of Engineers. In Hong Kong, all the public leisure and recreational facilities are procured by the Department. One common feature of these is the need to provide a large column free space by adopting large-span structures. The Department would like to deliver the attention on large-span structures to the public, together with professional engineers by sharing the extensive experience on these through these activities. Before the establishment of Architectural Services Department, Architectural Office has already dealt with large-span structures, such as Hong Kong Coliseum (Figure 1) where is a well known venue to hold international sport competitions and other recreational events. A large-scale steel space truss is adopted as the roof to create a large column free space.
Figure 1 Overall View of the Steel Truss
Large-span structure is increasingly receiving attention and appreciation from both the public and professional engineers. The Department has also widely chosen large-span structures in these recent projects, such as Ma On Shan Sports Centre (Figure 2). There is a dramatic large-span curved roof to form an 80m by 60m column free open space for the sport arena with unobstructed views from the spectators stand. The curved roof is elliptically shaped and symmetrical about the centrelines in plan. Two curved main steel trusses spanning 70m longitudinally provide the primary support for the roof system. The trusses are supported on
reinforced concrete columns through pin connections. Because of its structural elegance, this roof is accepted as a local landmark.
Structural steel is not only to form a space truss, but could also form a cable-strayed structure in constructing large-span structures. The cable-strayed supported roof of Tsing Yi Municipal Services Building (Figure 3) provides a positive contribution to the visual environment. The roof, hanged by a cable-strayed system, is composed of roof truss and concrete slab with steel decking.
Page 1 of 3
Steel mast and tension rod assembles the cable-strayed system. The wind uplift force on the roof is one of the critical considerations and is counterbalanced by the dead load, such that the tension rod would not experience any compressive force.
Figure 3 The Elevation View of the Roof
From the structural point of view, the bending moment would be significant when the span length increases. As lighter material is welcomed in practices, reinforced concrete is limited on this usage because of the greater dead load. However, in special circumstances, greater dead load is preferred, such as the roof of Hammer Hill Road Sports Playground (Figure 4). The roof of the stand is folded plate tapered at the end, while there is a solid concrete slab at the back span to increase the weight such that the bending moments Besides to common construction materials, timber could also be used to construct large-span structure. Glued-laminated timber, made in New Zealand, is used in Aberdeen Sports Playground (Figure 5). The timber forms the rafter, purlin and main beam for the roof of the spectator stand. To deal with durability, the timber is adopted for resisting deterioration.
at the supporting columns could be diminished by balancing the load between two spans.
In the choice of construction materials, there are numerous considerations, including construction method & safety, structural stability, environmental impact, architectural prestig and cost. Hong Kong Museum of Coastal Defence (Figure 6) is special in the choice of material; neither reinforced concrete nor structural steel was used for the large-span. Fabric membrane roof spanning 42 meters creates a vast central courtyard.
Page 2 of 3
This is the first enclosed fabric structure in Hong Kong and the membrane is prestressed with tension cables. The closure flap, made of PVC, is a coated polyester fabric reinforced by intermediate fibreglass strip. The merit of fabric is an environmental friendly material as the PTFE coated fibreglass is translucent allowing natural lighting. Designing the large-span structures, the choice of construction materials is important. Moreover, a more challenging aspect is construction safety as the construction often involves lifting procedure. As a result, safety aspect should be carefully supervised. The stability after completion is important, and the stability of partially completed structural component is also one of the critical stages, such that the construction sequence should be assessed to identify accident risks. In addition, operation and maintenance of the structures should be taken into account in the risk assessment. Environmental impact is increasingly regarded as an important issue in the public. The environmental friendly structures should be achieved as far as possible, such as implementing conservation of energy by using translucent fabric and reducing the consumption of natural resources by choosing recyclable materials. Through these activities for celebrating 20th anniversary of Architectural Services Department, the public could appreciate and understand the design and construction of long-span structures for public amenity buildings in Hong Kong. We are looking forward to having more longspan structures as landmarks in the future.
Page 3 of 3
the works agent for Government facilities development in the past two decades, Architectural Services Department ( ArchSD ) has been providing professional service to HK focusing on design, construction and maintenance for public facilities. Meanwhile, the aim of ArchSD in contributing to the building of a better working and living environment for the people of HKSAR has never been changed. Among the countless magnificent buildings designed by ArchSD, quite a number of these are renowned for their peculiar features. One of the common feature is the Large- Span requirement. The design and construction of large- span structure in fact took place through out the history of ArchSD. Some of these were introduced in the technical seminar and the site visit organised by ArchSD in August 2006.
Being
Kong Coliseum was designed and constructed by Architectural Office ( the forerunner of ArchSD ) in 1982. It provides the city with a well designed and equipped multipurpose indoor stadium where diversified activities can be staged. The roof truss of the
Fig. 1 Hong Kong Coliseum
Hong
coliseum spans 90 meters in both latitudinal and longitudinal directions, providing underneath space for 12,500 seats and an arena of 41m x 41m. The roof truss was assembled on the ground for the ease of fabrication before jacking up to the top of the four towers. This was one of the prominent projects at that time.
Kong Museum of Coastal Defense is located at the hillside of Lei Yue Mun Pass. Formerly known as the Lei Yue Mun Fort, it was built by the British forces more than a hundred years ago to defend the eastern approach of the harbour. ArchSD refurbished the fort into the Fig. 3 Hong Kong Museum of Coastal Defense present tremendous museum in 1999. The main exhibition gallery was covered up by a 42 meters diameter span fabric roof. The supporting tension structure consists of the central ring, valley cables, ridge cables, tie-down cables, main masts, perimeter masts and ground anchorages. The fabric structure has an irregular plan shape to follow the air-raid shelters underneath. PTFE coated membrane material is used as roofing for its lightweight and high tensile strength.
Hong
This splendid architectural design project was awarded the Hong Kong Institute of Architects Annual Awards 2001 Silver Medal.
There are many other large- span structures design and constructed by ArchSD. For
instance, Kowloon Bay Sports Ground, Choi Hung Road Playground, Hammer Hill Road Sports Ground, Spectator Stand at Aberdeen Sports Ground, Tsing Yi Sports Ground, Siu Sai Wan Sports Ground, Hammer Hill Road Swimming Pool, Tsuen Wan West Sport Centre, Ma On Shan Swimming Pool, Tsing Yi Municipal Services
Building, Shing Mun Valley Swimming Pool and Hong Kong Film Archive. Largespan structures in fact are not something distant but living between each of us. Nevertheless, one may ask how to classify a structural span as large. I believe every single one would have his/her own interpretation. As suggested by the Chief Structural Engineer of ArchSD, Ir. M. K. Tong, as a structural engineer, we should always treat every span as if it was a largespan. We should always try our every effort and enthusiasm in our design work. This innovative concept means a lot to the engineers of Fig. 9 Hammer Hill Road Swimming Pool, 1996 new generation. Not only to large- span structural design that we should need to ensure thorough and careful considerations have been given to find the best structural solutions, but also we should proud of every bits of our own work. As a young engineer, we should always try hard to take an Fig. 10 Siu Sai Wan Sports Ground, 1996 active part in the design team. Large- Span Structure definitely would become larger in the future design, this would be a challenge for structural engineer, but also this would be a chance to steel us up. As the old adage states "Chance favors the prepared mind", have you got a prepared mind?