Anda di halaman 1dari 16

Uniclass L7315 + L2123 CI/SfB (52.

5)

EPIC J3413

Next generation of surface drainage ACO ParkDrain

ACO ParkDrain
THE NEXT GENERATION OF SURFACE DRAINAGE
Load Class (BS EN 1433:2002)

Optimum solution
ACO ParkDrain is a one piece polymer concrete drainage system which has been designed as the optimum solution for a wide range of surface drainage applications requiring Load Class C 250 installations.

Benets for speciers


One piece design means no separate grating specications Colour choice to match location - black (asphalt) as standard, other colours available to order e.g. white and yellow (lines and markings), buff/beige (standard paving), red (brick paviours) etc. Simplied level and stepped system for quick scheme design

Lower costs
It has been specically designed to reduce installation time and provide inexpensive maintenance over its whole life. It offers cost advantages for architects, engineers, contractors and clients.

Benets for contractors


Simple scheme layouts with level invert units Easy to achieve excellent watertightness (to BS EN 1433:2002) with sealing groove Light weight (typically 16 - 20 kg/unit) for easy one man lift enables compliance with Health and Safety guidelines

Open-minded innovation
ACO ParkDrain is the result of over 30 years development of innovative surface drainage solutions for highways, local authority, retail, commercial and domestic users.

Benets for clients


Integral unit without separate grating style top eliminates lost or damaged gratings Unobtrusive, self-coloured grating maintains appearance and colour with time Rodding access units and sumps with separate locking resin composite grating, allows easy maintenance Resin concrete unaffected by frost No removable gratings makes system suitable for schools and play grounds

Standards compliance
ACO ParkDrain has been certicated to Load Class C 250 (BS EN 1433:2002) and BS EN 124:1994 for gully and access units. Contact ACO Technical Department for standards details and copies of Load Test certicates.

ACO Mini ParkDrain


FOR RESTRICTED DEPTH INSTALLATIONS
Load Class (BS EN 1433:2002)

NEW Introducing ACO Mini ParkDrain:


ACO Mini ParkDrain is a one piece polymer concrete drainage system suitable for applications with restricted installation depths. The system is suitable for a wide range of drainage applications requiring Load Class D 400 installations. This system is not designed for highway use where it can be trafcked by fast moving vehicles.

Benets for speciers


Shallow system suitable for minimal depth installations One piece design means no separate grating specications Suitable for applications requiring D400 installations*
* Not for highway use.

Benets for contractors


Lightweight design 1 metre unit for fast & simple installations Easy to achieve excellent water tightness with sealing groove

Lower installation costs


ACO Mini ParkDrain is lightweight and available in 1 metre length, aiding fast and simple installations.

Standards compliance
ACO Mini ParkDrain has been certicated and CE marked to Load Class D 400 BS EN 1433:2002.

Benets for clients


Integral drainage solution Minimal disruption during installation No removable grating makes system suitable for schools and playgrounds.

Free technical support


To support architects, engineers and contractors in designing and installing ACO ParkDrain and ACO Mini ParkDrain schemes, ACOs Design Services Team offers computer-aided scheme design, hydraulic performance calculations and installation advice services. Telephone Hotline:

01462 816666
Fax Hotline:

01462 851081
e-mail:

draintechnical@aco.co.uk
website:

www.aco.co.uk

ACO ParkDrain
CHANNEL DRAINAGE

Hydraulic choices with ACO ParkDrain*


1. Constant invert, level ground

- effective drainage but may need more regular maintenance due to greater chance of silting.

2. Constant invert, sloped ground

- improved hydraulic capacity over system 1.

3. Stepped invert, level ground

- will give a similar hydraulic capacity to system 2.

*ACO Mini ParkDrain only available as constant invert

Resin concrete
Minimal lifetime maintenance 3 - 4 compressive strength of OPC (Ordinary Portland Cement), so products can be made lighter Water absorption < 0.01% by weight*

Compressive Strength
10 20 30 40 50 60 70 80 90 100

strength (N/mm2)

G la ss

O i rd r na fo in e rc d re

s Re in co t re nc e* cr t re nc e e et y n co

co

Water Absorption
0.5

depth (mm)

1.0 1.5 2.0

G la ss re

O i rd na fo ed rc -in

sin Re co nc * te re e t re e t re nc nc co

ry co

4
*
BBA report No. 1580

Sump unit
PD100C 10.3 PD100C 108 PD100C 10.1 PD100C 15.1 PD900C PD100C 208 PD100C 20.3 PD100C 123 PD100C 20.1 PD100C 306 PD100C 25.1 PD100C 30.3 PD100C 308 PD100C 30.1

Step connector

Closing endcap

Inlet/outlet endcap

Rodding access unit

Level invert channel

CHANNEL RANGE LAYOUT

ACO ParkDrain

ACO ParkDrain
INNOVATION IN APPLICATION

ACO ParkDrain is the next generation of surface drainage with major advantages in car parks, pedestrianised areas and hard-landscaped locations. Its one piece design with integral grating means it is not vulnerable to vandalism or loosening. Rodding Access units and the universal Sump unit ensure easy maintenance. It is a product especially recommended to be used in schools where children play due to its monoblock composition it has no removable parts which could lead to injury. Its Load Class C 250 certication means it can be deployed in a wide number of locations where light vehicle trafc can be expected.

Its unique colouring means it can either be unobtrusively blended with its surroundings - e.g. coloured as the adjoining pavement - or used as a marker or even signage e.g. coloured white or yellow to mark roads. The colour is maintained, no rubbing off or being dissolved. It is compatible with all types of paving materials, and the at sides enable pavements to be laid directly to the units edge.

ACO Mini ParkDrain


Complementing the range, ACO Mini ParkDrain is specically designed to provide a drainage solution for small drainage areas and applications that have restricted depth installation.

ACO ParkDrain
HYDRAULIC PERFORMANCE TABLES

Total design ow capacities l/s for each constant depth channel assuming lateral inow to channel.
PD100C 10.1 Overall depth = 250mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 9.0 10.5 11.7 10 8.4 10.9 12.6 15 8.1 11.3 13.5 20 7.8 11.5 14.0 25 7.4 11.7 14.4 30 7.1 12.0 14.7 40 6.7 12.0 15.0 60 6.1 12.0 15.3 80 5.6 12.1 15.5 PD100C 15.1 Overall depth = 275mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 11.1 12.9 14.2 10 10.4 13.3 15.4 15 10.0 13.6 16.0 20 9.6 13.8 16.6 25 9.3 14.0 17.1 30 8.9 14.1 17.6 40 8.3 14.3 18.2 60 7.6 14.5 18.4 80 7.0 14.7 18.6 PD100C 20.1 Overall depth = 300mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 13.5 15.5 17.1 10 12.6 15.8 18.1 15 12.0 16.1 18.8 20 11.3 16.3 19.4 25 10.9 16.4 20.1 30 10.4 16.5 20.6 40 9.8 16.7 21.0 60 9.2 16.8 21.3 80 8.5 17.0 21.7 PD100C 25.1 Overall depth = 325mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 16.1 18.2 19.9 10 15.1 18.4 21.0 15 14.3 18.6 21.8 20 13.6 18.8 22.3 25 13.0 19.0 22.7 30 12.4 19.1 23.1 40 11.7 19.2 23.6 60 11.0 19.2 24.1 80 10.1 19.4 24.8 PD100C 30.1 Overall depth = 350mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 18.9 21.1 22.9 10 17.9 21.2 24.1 15 17.0 21.4 24.8 20 16.2 21.6 25.3 25 15.4 21.6 25.8 30 14.6 21.7 26.2 40 13.8 21.7 26.7 60 12.1 21.8 27.2 80 11.8 21.9 27.9 PD100C 10.1/PD100C 15.1/ PD100C 20.1/PD100C 25.1/PD100C 30.1 Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 25.6 25.6 26.4 10 24.7 25.6 25.7 15 23.3 25.2 25.3 20 20.3 24.0 25.0 25 16.9 22.0 24.9 30 13.5 20.7 24.8

1.5% 12.9 14.2 15.1 15.9 16.5 17.1 17.7 18.5 19.2

1.5% 21.4 22.7 24.0 25.1 25.9 26.7 27.4 28.2 28.6

1.5% 15.4 17.1 18.0 18.8 19.3 20.0 20.6 21.4 22.5

1.5% 24.6 26.3 27.6 28.5 29.4 30.1 30.9 31.7 32.1

1.5% 18.2 19.7 20.9 21.9 22.8 23.7 24.5 25.5 26.6

1.5% 26.8 26.2 25.9 25.9 25.9 26.0

Total design ow capacities in I/s for a stepped channel system assuming equal numbers of each height of channel are used with step transition channels.

7
Note: Refer to ACO Technical Handbook and Design Guide for further hydraulic details.

ACO Mini ParkDrain


HYDRAULIC PERFORMANCE TABLES

Maximum total ow capacities (l/s) for each constant depth channel, assuming lateral inow to the channel
ACO Mini ParkDrain Overall depth = 125mm Length to outlet Flow (I/s) Ground slope (m) 0.0% 0.5% 1.0% 5 1.4 1.9 2.2 10 1.3 2.0 2.4 15 1.2 2.1 2.5 20 1.1 2.2 2.6 25 1.1 2.3 2.7 30 1.0 2.4 2.8 35 1.0 2.4 2.8 40 0.9 2.5 2.9

1.5% 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2

The maximum catchment depth drained by the channel may be derived from the tables. For total ow Q (l/s); Catchment Depth CD (m); Length of channel to outlet Lo (m); Rainfall intensity i (l/s/m2) Then Q = CD x Lo x i. Hence CD = Q / (Lo x i)

ACO Mini ParkDrain


PARTS TABLE

Channels
Dimensions (mm) Depth Overall Invert 125 105 Weight (kg) 24.7 Connections Availability Closing Sumps Endcaps PD900C Mini ParkDrain 306 closing end cap

Description Mini ParkDrain

Order No. 30125

Length 1000

150mm

1000mm

Access unit
Dimensions (mm) Depth Overall Invert 125 105 Weight (kg) 28.5 Connections Availability Closing Sumps Endcaps PD900C Mini ParkDrain 306 closing end cap

Description Mini ParkDrain access

Order No. 31253

Length 1000

125mm

125mm

150mm

1000mm

Access unit has performed 110mm knockout under access cover for vertical outlet End cap
Description Mini ParkDrain 306 closing end cap Order No. 30306 Dimensions (mm) Depth Overall Invert 305 150mm Wide Bore Overall 150 Length 25 Weight (kg) 2.5

25mm

305mm

105mm

105mm

ACO ParkDrain
PARTS TABLE

Channels
Fall Type Order No. Level Sloped L L L L L Dimensions (mm) Depth Overall Invert 250 275 300 325 350 225 250 275 300 325 Weight (kg) 16.3 17.3 18.3 19.3 20.3 Connections Availability Endcaps Sumps Closing PD900C PD900C PD900C PD900C PD900C Step Connector PD100C 123 PD100C 123

Description

Length 500 500 500 500 500

Inlet/outlet

PD100C 10.1 30101 PD100C 15.1 30151 PD100C 20.1 30201 PD100C 25.1 30251 PD100C 30.1 30301

PD100C 306 PD100C 108 PD100C 306 PD100C 306 PD100C 208 PD100C 306 PD100C 306 PD100C 308

150mm 250-350mm

500mm

100mm

Channel

10
Note: As with all pre-cast products, polymer concrete units are subject to weight and dimensional tolerances.

ACO ParkDrain
PARTS TABLE

PD100C Rodding access/junction unit


Fall Type Order No. Level Sloped 30103 30203 30303 L L L Dimensions (mm) Depth Overall Invert 250 300 350 225 275 325 Weight (kg) 13.0 15.0 17.0 Connections Availability Endcaps Sumps Closing PD900C PD900C PD900C Step Connector PD100C 123 PD100C 123

Description PD100C 10.3 PD100C 20.3 PD100C 30.3

Length 500 500 500

Inlet/outlet

PD100C 306 PD100C 108 PD100C 306 PD100C 208 PD100C 306 PD100C 308

150mm

500mm

100mm

250-350mm

110mm

Rodding access/junction unit Endcaps


Dimensions (mm) Depth Overall Invert 350 250 300 350 225 275 325 Width Bore 100 100 100 Weight (kg) 2.5 1.5 1.8 2.1

Description PD100C 306 Closing PD100C 108 Inlet/outlet PD100C 208 Inlet/outlet PD100C 308 Inlet/outlet

Order no. 30306 30108 30208 30308

Overall 150 150 150 150

Length 25 25 25 25

105mm 150mm 25mm 150mm 25mm

350mm

Closing endcap Step connector

inlet/outlet endcap

Description PD100C 123 Step connector

Order no. 30123

Dimensions (mm) Depth Overall Invert 50

Width Bore 94

110mm

Overall 150

Length 123

Weight (kg) 0.9

Step connector

11

Rodding Access/Junction unit can be inserted between Constant Depth units with matching overall/invert depths.

ACO ParkDrain
PARTS TABLE

Sump unit
Dimensions (mm) Depth Overall Invert 665 640 Width Bore 100 Weight (kg) 35

Description PD900 C Standard sump unit 500mm

Order no. 30900

Overall 150

Length 500

665mm

640mm

480mm

Sump unit Foul air traps


Dimensions (mm) Depth Overall Invert 375mm 27.4 l/s 395 375 480 435 480mm Width Bore 100 150 100 150 Weight (kg) 0.5 1.9 0.6 0.8

Description 920 Foul air trap PVC-U 110mm 922 Foul air trap PVC-U 160mm

Order no. 2640 2638

640mm

380mm

Overall 110 160 110 160 435mm 30.1 l/s

Length -

940 Roddable foul air trap MDPE 110mm 7931 950 Roddable foul air trap MDPE 160mm 7932 395mm

13.1 l/s

14.6 l/s

920 Foul air trap PVC-U 110mm

922 Foul air trap PVC-U 160mm

940 Roddable foul air trap MDPE 110mm

950 Roddable foul air trap MDPE 160mm

Description 820 Drain union PVC-U 110mm 822 Drain union PVC-U 160mm

Order no. 0056 0058

Dimensions (mm) Depth Overall Invert -

Width Bore 100 150

Overall 110 160

Length 100 150

Weight (kg) 0.1 0.5

820 Drain union PVC-U 110mm

822 Drain union PVC-U 160mm

12
*
Sump unit knockouts suit Constant Depth unit depths as indicated in the product table. ACO sump units allow two way drainage unit connection with discharge to sub-surface drainage.

Note: See product table to matching inlet/outlet endcap with correct drainage unit. Outlet endcaps are supplied as two components to be site assembled to suit ow direction.

ACO ParkDrain & ACO Mini ParkDrain


SITEWORK INSTALLATION

1.0 Ground Conditions The customer should ensure that the minimum dimensions shown are suitable for the existing ground conditions. Engineering advice may be necessary. 2.0 Block Pavements The channel must be supported laterally and therefore blocks must be restrained from movement by bedding securely e.g. by using a Polymer Modied Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C from Ronacrete: Tel 01279 638 700). Engineering advice may be required. 3.0 Surface Cracks Alternate crack control and movement joints transversely within bed and haunch may reduce unsightly surface cracking. 4.0 Joint Sealant Where ACO Drain channel joints and ttings are to be sealed (where used in foul water applications or where impermeability is required) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface Protection In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the nished surface level lies above the grating level (by at least 3mm) Stones should be removed prior to laying/rolling wearing course.

ACO ParkDrain
(To Load Class C 250)

ACO Mini ParkDrain


(To Load Class D 400)

Asphalt pavement
Top of haunch 25mm maximum below wearing course. See Note 5.0

Asphalt pavement
See Note 5.0

150mm

Concrete bed and haunch minimum compressive strength 25 N/mm2

Concrete pavement
Note: Movement joint to Engineers detail Concrete slab

150mm

Concrete bed and haunch minimum compressive strength 25N/mm2

Minimum 200mm Minimum 200mm

Concrete pavement
Concrete slab Note: Expansion joint to engineers detail Concrete slab

150mm

Concrete bed and haunch minimum compressive strength 25 N/mm2

Block pavement

150mm

Concrete bed and haunch minimum compressive strength 25N/mm2

Block pavement
Note: Block bedded using mortar (see note 2.0) Option 1 Block Block Option 2 Block

150mm 150mm

Minimum 200mm Concrete bed and haunch minimum compressive strength 25N/mm2 Minimum 200mm

Concrete bed and haunch minimum compressive strength 25 N/mm2

150mm

Minimum 200mm

Minimum 200mm

Approx 225mm

Note: For ACO Mini ParkDrain installations to Load Class C 250, the minimum concrete bed and surround may be reduced to 150mm.

13

ACO ParkDrain

Model Specication Clause


The surface drainage system shall be as ACO ParkDrain channels as supplied by ACO Technologies plc; all materials and components within the scope of this system shall be obtained from this manufacturer. The system shall be certied to BS EN 1433:2002 Load Class C 250 and BS EN 124:1994 for the access and gully unit covers; load test certicates shall be supplied to the Supervising Ofcer. The system shall be of units 500mm long, 100mm nominal internal width, 150mm external width, one piece manufacture in polyester resin concrete, with integral resin concrete grating featuring 8mm wide downward ared inlet slots to ACO registered pattern providing a minimum inlet area of 18,300mm2 per metre. The standard units shall be installed with the manufacturers level invert and transitional sloping invert units, rodding access, sump and accessories as required for the scheme. The system shall be installed in accordance with the manufacturers printed recommendations, and the work carried out as specied on the Supervising Ofcers drawing no.* and in accordance with recognised good practice. Standards of workmanship shall generally be as specied in BS EN 752:2008 and BS 8000:Part 14:1989.

Please insert drawing no. relevant to the project.

14

ACO Mini ParkDrain

Model Specication Clause


The surface drainage system shall be as ACO Mini ParkDrain channels as supplied by ACO Technologies plc; all materials and components within the scope of this system shall be obtained from this manufacturer. The system shall be certied to BS EN 1433:2002 Load Class D 400 and BS EN 124:1994 for the access and gully unit covers; load test certicates shall be supplied to the Supervising Ofcer. The system shall be of units 1000mm long, 100mm nominal internal width, 150mm external width, one piece manufacture in polyester resin concrete, with integral resin concrete grating featuring 8mm wide downward ared inlet slots to ACO registered pattern providing a minimum inlet area of 18,300mm2 per metre. The standard units shall be installed with the manufacturers level invert units, rodding access, sump and accessories as required for the scheme. The system shall be installed in accordance with the manufacturers printed recommendations, and the work carried out as specied on the Supervising Ofcers drawing no.* and in accordance with recognised good practice. Standards of workmanship shall generally be as specied in BS EN 752:2008 and BS 8000:Part 14:1989.

Please insert drawing no. relevant to the project.

Technical Support Services


To support architects, engineers and contractors in designing and installing ACO ParkDrain schemes, ACOs Design Services Department offers computer-aided scheme design, hydraulic performance calculations and installation advice services. Our Telephone Hotline 01462 816666, Fax Hotline 01462 851081, e-mail draintechnical@aco.co.uk and website www.aco.co.uk enable us to give you the response you need.

15

ACO Technologies plc ACO Business Park, Hitchin Road, Shefford, Bedfordshire SG17 5TE Tel: 01462 816666 Fax: 01462 815895 e-mail Sales: customersupport@aco.co.uk e-mail Technical: draintechnical@aco.co.uk website: www.aco.co.uk

March 2010 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customer's responsibility to ensure that each product is t for its intended purpose, and that the actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of continuous product development and improvement renders specications liable to modication. Information provided in this brochure is therefore subject to change without prior notication. ACO CARES ABOUT THE ENVIRONMENT Printed on material approved by the Forest Stewardship Council (FSC) who provide a means of assuring that products come from sustainably managed forests.

PC20714

Anda mungkin juga menyukai