Anda di halaman 1dari 564

Cables

and
Wires

Productrange...
CC-Schleppflex
(HighFlexibleCablesforMobilePowerSupplyChainApplications)
CC-ServoandCC-Servoflex
(FlexibleandHighFlexibleMotor-SupplyCables,ShieldedandUnshielded)
CC-FeedbackandSensorCable
(FlexibleandHighFlexibleMobilePowerSupplyChainCables
forMultipleApplications)
CC-ControlCables,ShieldedandUnshielded
(AlsoforIntrinsicallySafeCircuits)
CC-HighTemperatureCables
(EVA,Silicone,FEP,PTFE)
CC-CommunicationandDataCables
(Coax,TelephoneandLWLCablesforIn-andOutdoorUse)
CC-ComputerCables
(ForLANApplications)
CC-CompensatingCables(ShieldedandUnshielded)
CC-BUSandCC-BUSSchleppflex
(PrOFIBUS,CAN-BUS,BITBUS,AS-I-BUS,DeviceNet,Foundationfieldbus
Safetybus...FlexibleandHighFlexibleFieldbusCablesforMultipleApplications)
CC-rubberCables
CC-FlatCables
(FlexibleandHighFlexible)
CC-SpiralCablesandPre-AssembledCables
CC-SpecialCables
(ConstructionAccordingtoYourSpecifications)

forYourNeeds!

Morethan30yearsofexperiencewithcables
andcorrespondingcustomerfidelityconfirmthat
wearetherightpartnerforyouworldwide.
Ourextensivestandardproductlineaswellas
ourcablespecialistsofferyouacablesolution
foranyapplication,nomatterhowextraordinary.
Ourjustintimecomittmentallowsustofill
yourordersquickly.Backedbyoursubstantial
inventory,weordinarilyshipoutyourorders
within24hours.

Table of Contents
DESINA Overview

16

Cable overview DESINA

17

Overview

18

Robust cables for high mechanical and microbes resistance


CC-controlcablerobust-JZ-500highmechanicalandmicrobesresistance,halogen-free,300/500V
CC-controlcablerobust-JB/JZ-501highmechanicalandmicrobesresistance,halogen-free,450/750V
CC-controlcablerobust-C-JZ-502 highmechanicalandmicrobesresistance,halogen-free,shielded
CC-Schleppflex robust-JZ-503*highflexible,highmechanicalandmicrobesresistance,halogen-free
CC-Schleppflex robust-C-JZ-504*highflexible,highmechanicalandmicrobesresistance,halogen-free,shielded

20
22

24
26
28

High flexible PVC-cables for power chain systems


CC-Schleppflex PVC-570highflexibledatacable*
CC-Schleppflex PVC-570 andhighflexibledatacable*
CC-Schleppflex PVC-570highflexiblecontrolcable*

30
32
34

CC-Schleppflex PVC-570 and highflexiblesinglecorecable*


CC-Schleppflex PVC-570 and highflexiblecontrolcable
CC-Schleppflex PVC-C-573highflexibledatacable,shielded*
CC-Schleppflex PVC-C-573 and highflexibledatacable,shielded*
CC-Schleppflex PVC-C-573highflexiblecontrolcable,shielded*

38
40
42
44
46

CC-Schleppflex PVC-C-573 and DESINAhighflexiblesinglecorecable,shielded*


CC-Schleppflex PVC-C-573 and highflexiblecontrolcable,shielded*

48
50

High flexible PUR-cables for power chain systems


CC-Schleppflex PUr-575highflexibledatacable*
CC-Schleppflex PUr-575highflexiblecontrolcable*
CC-Schleppflex PUr-575 and highflexiblecontrolcable
CC-Schleppflex PUr-C-576highflexibledatacable,shielded*
CC-Schleppflex PUr-C-576highflexiblecontrolcable,shielded*

ConCabkabelconnectstheworld

52
54
56
58
60

CC-Schleppflex PUr-C-576 and highflexiblecontrolcable,shielded *


CC-Schleppflex PUr-572halogen-free,superflexibledatacable*
CC-Schleppflex PUr-574 andlowcapacitance,halogen-free,superflexibledatacable*
CC-Schleppflex PUr-572halogen-free,superflexiblecontrolcable*
CC-Schleppflex PUr-572 and superflexiblecontrolcable*
CC-Schleppflex PUr-574 andlowcapacitance,halogen-free,superflexiblecontrolcable*
CC-Schleppflex PUr-C-569halogen-free,superflexibledatacable,shielded*
CC-Schleppflex PUr-C-592 andlowcapacitance,halogen-free,superflexibledatacable,shielded*
CC-Schleppflex PUr-C-569halogen-free,superflexiblecontrolcable,shielded*
CC-Schleppflex PUr-C-569 and superflexiblecontrolcable,shielded*
CC-Schleppflex PUr-C-592 andlowcapacitance,halogen-free,superflexiblecontrolcable,shielded*
CC-controlcablePUr-571 and halogen-freerobustcontrolcable600V
CC-controlcablePUr-C-568 and halogen-freerobustcontrolcable600V, shielded
CC-Schleppflex PUr-C-(TP)-510 and highflexiblepaireddatacable,shielded*
CC-Schleppflex PUr-C-(TP)-512halogen-free,superflexiblepaireddatacable,shielded*
CC-Schleppflex PUr-C-(TP)-513 and lowcapacitance,halogen-free,superflexiblepaireddatacable,shielded*

62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92

Feedback and Sensor Cables


CC-PVC-C-251flexible,shielded
CC-PVC-C-251 and DESINA flexible,shielded
CC-PUr-C-181halogen-free,superflexible,shielded*
CC-PUr-C-181 and DESINA halogen-free,superflexible,shielded *
CC-PUr-C-281 and DESINA lowcapacitance,halogen-free,superflexible,shielded

94
96
98
100
102

Motor-Supply Cables
CC-ServoPVC-586 andDESINA motor-supplycable0,6/1kV
CC-ServoPVC-C-585 and DESINA motor-supplycable0,6/1kV,shielded
CC-Servo2Y-(St)-CY-587lowcapacitancemotor-supplycableforfrequencyconverters0,6/1kV,shielded
CC-Servo2Y-(St)-CH-1587halogen-free,lowcapacitance motor-supplycableforfrequencyconverters0,6/1kV,shielded
CC-ServoflexPUr-580 halogen-free,superflexiblemotor-supplycable0,6/1kV*
CC-ServoflexPUr-580 and DESINA halogen-free,superflexiblemotor-supplycable0,6/1kV*
CC-ServoflexPUr-C-581DESINA halogen-free,superflexiblemotor-supplycable0,6/1kV,shielded*
CC-ServoflexPUr-C-581 and DESINA halogen-free,superflexiblemotor-supplycable0,6/1kV,shielded*
CC-ServoflexPUr-C-583 and DESINA lowcapacitance,halogen-free,superflexiblemotor-supplysinglecorecable

106
108
110
110
112
114
116
118
120

0,6/1kV,shielded

CC-ServoflexPUr-C-583 and DESINA lowcapacitance,halogen-free,superflexiblemotor-supplycable0,6/1kV,shielded*122


CC-ServoflexPUr-588 and DESINA lowcapacitance,halogen-free,superflexiblemotor-supplysinglecorecable0,6/1kV 124
CC-ServoflexPUr-588 and DESINA lowcapacitance,halogen-free,superflexiblemotor-supplycable0,6/1kV
126
CC-ServoPVC-573motor-supplyandfeedbackcable0,6/1kV
128

CC-ServoPVC-C-577 and DESINA motor-supplyandfeedbackcable0,6/1kV,shielded


130

ConCabkabelconnectstheworld

CC-ServoflexPUr-579superflexiblemotor-supplyandfeedbackcable0,6/1kV*
140

CC-ServoflexPUr-C-582DESINA halogen-free,superflexiblemotor-supplyandfeedbackcable0,6/1kVshielded*
142

CC-ServoflexPUr-C-582 and DESINA halogen-free,superflexiblemotor-supplyandfeedbackcable0,6/1kV,shielded* 144


CC-ServoflexPUr-C-584 and DESINA lowcapacitance,halogen-free,superflexiblemotor-supplyandfeedbackcable
0,6/1kV,shielded*
146

CC-Servoflex-LinearPUr-C-592 and DESINA halogen-free,superflexiblemotor-supplyandfeedbackcable


0,6/1kV,shielded*
148

Servo-Motor Cables and Feedback Cables for Siemens and Indramat Systems
CC-ServoandfeedbackcablesforSiemenssystemsPVC-C and shielded
CC-ServoandfeedbackcablesforSiemenssystemsPUr-C and halogen-free,shielded
CC-ServoandfeedbackcablesforSiemenssystemsPUr-C andlowcapacitancehalogen-free,shielded
CC-ServoandfeedbackcablesforIndramatsystemsPUr-C andlowcapacitancehalogen-free,shielded

132
134
136
138

Robotic Cables
CC-robotflexPUr-90halogen-freeroboticcable*
CC-robotflexPUr-C-91halogen-freeroboticcable,shielded*

150
152

Sensor-Actuator Cables
CC-Sensor-ActuatorPVC-566datacablefordecentralizedmachineinstallations
CC-Schleppflex-Sensor-ActuatorPUr-567 DESINA anddistributioncable,superflexible*

154
155

Fieldbus Cables
OverviewCC-BUS-Cables
CC-BUSPVC-C-93,CC-BUS-H-C-93 and DESINAflexiblefieldbuscable,shielded
CC-BUS-Schleppflex PUr-C-94 and DESINA halogen-free,superflexiblefieldbuscable,shielded*
CC-BUS-SAFETYPUr-C-94 and halogen-free,safety-buscable,shielded*
CC-BUS-FF-PVC-C-913 Foundation fieldbuscable, shielded*
CC-BUSCAN-PVC-C-93 and DESINA CAN-Buscable,shielded
CC-BUS-Schleppflex CAN-PUr-C-94 DESINA halogen-free,superflexibleCAN-Buscable,shielded*
CC-BUSAS-Interfacetwo-corefieldbuscable*
CC-BUS-EIBBUS-installationcablePVCorhalogen-free
CC-BUS-Schleppflex Hybrid-PUr-931DESINA superflexiblefieldbuscompositecablewithPOF*
CC-BUSPVC-C-910( ) and fieldbusforDeviceNet,shielded
CC-BUS-Schleppflex PUr-C-911 and halogen-freefieldbuscableforDeviceNet,shielded*
CC-Ether-Bus-C-(TP)-471DESINA halogen-free ETHErNETfieldbuscableCAT5/100MHz,shielded
CC-Schleppflex Ether-Bus-C-(TP)-471DESINA highflexible,halogen-free ETHErNETfieldbuscable
CAT5/100MHz,shielded

CC-BUSPA-C-95PrOFIBUSPAfieldbuscableforapplicationinexplosiveareas

ConCabkabelconnectstheworld

156
158
160
162
164
166
167
168
170
171
172
173
174
175
176

PVC-Control Cables
CC-controlcable-JZ-110
CC-controlcables-OZ112
CC-controlcable-JB-111
CC-controlcable-101(bluecores)
CC-controlcable-102(redcores)
CC-controlcableblue-JZ-107
CC-controlcableblue-OZ-117
CC-controlcableorange-JZ-08
CC-controlcableyellow-JB-09
CC-controlcableblack-JZ-5860,6/1kV

180
180
183
186
186
188
188
190
191
192

PVC-Control Cables shielded


CC-controlcable-JZ-CY-130
CC-controlcable-JB-CY-131
CC-controlcableblue-OZ-CY-127
CC-controlcableblack-JZ-CY-1360,6/1kV
CC-controlcable-JZ-SY-120
CC-controlcable-JB-SY-121

196
198
200
202
204
206

PVC-Control Cables with Approvals


CC-controlcableH05VV5-F-115
CC-controlcableH05VVC4V5-K-116
CC-Multinorm-167, andHAr
CC-Multinorm-CY-168,andHAr
CC-Control-Tray-TM-170 flexibleoilresistantcontrolcable600Vforcabletraysandopenwiring
CC-Control-Tray-TM-CY-171 flexibleoilresistantcontrolcable600Vforcabletraysandopenwiring,shielded
CC-controlcable-CEI-Fr-162

210
212
214
217
220
222
224

PUR-Control Cables with and without Approvals


CC-controlcablePUr-JZ-141
CC-controlcablePUr-OZ-148
CC-ZweinormPUr-141 and 
CC-controlcablePUr-C-JZ-142
CC-controlcablePUr-C-OZ-144
CC-ZweinormPUr-C-142 and 
CC-controlcablePUr-JZ-143
CC-controlcablePUr-C-JZ-152
CC-controlcableyellowPUr-JB-147
CC-appliancelink-upcableH05BQ-F/H07BQ-F-140

10

ConCabkabelconnectstheworld

228
228
230
232
232
234
236
238
244
245

Halogen-free Control Cables


CC-controlcableH-1110
CC-controlcableH-CH-1130
CC-controlcableH-1111300/500V

247
250
252

Data Cables unshielded and shielded


CC-datacableLiYY-210
CC-datacableLiYY-(TP)-230
CC-datacableLiYCY-220
CC-datacableLiYCY-220 and 
CC-datacableLiYCY-JZ-226
CC-datacableLiYCY-OZ-223
CC-datacableLiYCY-JB-225
CC-datacableLiYCY-(TP)-240
CC-datacableblueLiYCY-(TP)-128
CC-datacableLiYCY-CY-224
CC-datacableLiYCY-CY-(TP)-241
CC-datacableLiY-LiYDY-Y-222
CC-datacableLiFYDY-243
CC-datacableLiFYCY-(TP)-244

256
260
262
268
270
274
276
278
280
281
282
284
285
286

Halogen-free Data Cables


CC-datacableLiHH-217
CC-datacableLiHCH-227
CC-datacableLiHCH-(TP)-228
CC-datacableLi2YH-216
CC-datacableLi2YCH-247
CC-datacableLi2YCH-(TP)-248

288
291
294
296
299
302

Instrumentation and Signal Cables


CC-datacablelow-capacitance Li2YCY-(TP)-245
CC-datacableLi2YCYv-(TP)-246
CC-datacableLVCC-271
CC-datacablePiMFLi2YCY-270
CC-installationcableJE-Y(St)Y...Bd-430
CC-datacableJE-LiYCY...Bd-260
CC-datacableblueJE-LiYCY...Bd-261
CC-computercableJ-2Y(St)Y...St-IIIBd-421

ConCabkabelconnectstheworld

306
307
308
310
314
315
316
317

11

CC-computercablebluerE-2Y(St)Y-(TP)-436
CC-computercableblackrE-2Y(St)Y-(TP)-437
CC-computercablePiMFrE-2Y(St)Y-(TP)-431
CC-processcontrolcablerD-Y(St)Y-(TP)-432
CC-processcontrolcablerD-Y(St)Yv-(TP)-435

318
320
322
324
326

LAN- (CAT), Coax-, Monitor- and Fibre Optic Cables


CC-LANF/UTPJ-02YS(St)...-(TP)-471
CC-LANSF/UTPJ-02YS(St)C...-(TP)-471
CC-LANS/FTPPiMFJ-02YS(St)C...-(TP)-471
CC-LAN-cableforEthernet
CC-LAN-cableforToken-ring
CC-coaxialcable-305
CC-monitorcable-300
CC-POF-cable
CC-indoorfibreopticcable-0106
CC-fibreoptic-breakoutAT-V(ZN)HH-0104
CC-fibreopticminibreakoutcableI-V(ZN)H-0105
CC-fibreopticuniversalcable-0102
CC-fibreopticoutdoorcable-0103

328
330
332
334
335
336
336
340
341
342
343
344
346

Telephone Cables and Fire Alarm Cables


CC-telephonecableJ-YY...Bd-410
CC-telephonecableJ-Y(St)Y...Lg-420
CC-firealarmcableJ-YY...Bd-481
CC-firealarmcableJ-Y(St)Y...Lg-480
CC-firealarmcableJE-H(St)H...Bd-484E30/FE180halogen-free
CC-firealarmcableJE-H(St)H...Bd-485E90/FE180halogen-free
CC-firealarmcableJE-H(St)HrH...Bd-483E90/FE180halogen-free
CC-telephonecableJ-H(St)H...Bd-421halogen-free
CC-firealarmcableJ-H(St)H...Bd-482halogen-free
CC-telephoneoutdoorcableA-2Y(L)2Y...StIIIBd-440
CC-telephoneoutdoorcableA-2YF(L)2Y...StIIIBd-450

350
352
354
355
356
358
360
362
364
366
368

Compensating Cable
CC-compensatingcable-800

371

Rubber Cables and Welding Cables


CC-flexiblerubbercableH05rr-F-710
CC-flexiblerubbercableH05rN-F-720
CC-flexiblerubbercableH07rN-F/A07rN-F-730

12

ConCabkabelconnectstheworld

377
377
377

CC-rubbercableNSGAFU-350
CC-rubbercableNSHXAFU-358
CC-weldingcableH01N2-D/H01N2-E-355
CC-Hydro-N-722
CC-Hydro-T-724
CC-Hydro-T-flat-726

380
382
384
386
388
390

Lift- and Conveyor Cables


CC-Lift-H-180
CC-Lift-S-186
CC-Lift-2S-187
CC-flatcableH05VVH6-F/H07VVH6-F-118
CC-flatcablePVC-CY-192
CC-flatcableneoprene-731
CC-flatcableneopreneC5G-735
CC-cranecableNSHTU-732
CC-cranecablePUr-190
CC-cranecableNSHTUK-Z-742
CC-controlcableNeorund-733,neoprenecontrolcableweatherresistant
CC-rubbercableNSSHU-750

393
394
395
396
398
400
402
404
406
408
410
412

Temperature Resistant Cables


CC-Therm105C-600
CC-Therm150C-385
CC-Therm150C-371
CC-Therm150C-C-372
CC-siliconesinglecoreSiF-325
CC-siliconesinglecoreSiF/GL-330
CC-siliconesinglecoreSiD-335
CC-siliconesinglecoreSiD/GL-336
CC-siliconesinglecoreSiFF-340
CC-siliconesinglecoreSiF-353 and
CC-siliconesinglecore-3861,1-13,8kV
CC-siliconesinglecoreH05SJ-K-331
CC-siliconesinglecoreH05S-K-332
CC-siliconesinglecoreH05S-U-333
CC-siliconehook-upwireSiZ-341
CC-siliconehook-upwireFZL-Si-326
CC-siliconehook-upwireFZL-Si/GL/Si-327
CC-siliconecableSiHF-610
CC-siliconecableSiHF-610 and

ConCabkabelconnectstheworld

416
418
420
422
426
426
426
426
426
428
430
432
432
432
434
434
434
436
438

13

CC-siliconecableH05SS-F-611
CC-siliconecableSi-C-Si-614
CC-siliconecableSi-C-Si-614 and
CC-siliconecable-C-Si-616
CC-siliconecableSiHF-GLS-630
CC-singlecoreFEP/PTFE-348,metricdimensions
CC-singlecoreFEP/PTFE-345,AWG-dimensions
CC-flexiblecableFEP-639
CC-flexiblecablePTFE-640
CC-Nonflamsinglecore450C-329
CC-Nonflamsinglecore1400C-328
CC-Nonflam-multicorecable450C-629
CC-Nonflam-multicorecable1400C-628

440
442
444
446
448
450
452
454
456
458
459
460
462

Solar Cables
CC-Solar120C-387

424

Power Cables
CC-powercableNYY-J-802
CC-powercableNYY-O-804
CC-powercableNYCY-820
CC-powercableNYCWY-810
CC-installationcableNYM-J-808
CC-installationcableNYM-O-807
CC-installationcable(N)HMH-J-880
CC-installationcable(N)HMH-O-881
CC-installationcableNHXMH-J-850
CC-installationcableNHXMH-O-851
CC-powercableN2XH-J-856
CC-powercableN2XH-O-857
CC-powercableN2XCH-858
CC-powercableNHXH-J/OE30/FE180-860
CC-powercableNHXCHE30/FE180-861
CC-powercableNHXH-J/OE90/FE180-862
CC-powercableNHXCHE90/FE180-863

464
466
468
470
472
472
474
474
476
476
478
478
480
482
484
486
488

Hook-up Wires
CC-singlecorePVCLiYv-365
CC-singlecorePVCH05V-K/A05V-K-370
CC-singlecorePVCH07V-K/A07V-K-380
CC-singlecorePVCH05V2-K/H07V2-K-384

14

ConCabkabelconnectstheworld

492
492
492
494

CC-singlecorePVCLiFY-363
CC-singlecorePVCUL-Style1007/1569 and
CC-multinormMTW/AWM-CSA-HArULStyle1007/1569
CC-singlecorePVCUL-Style1015/1028/1283/1284 and ,MTWorAWM
CC-multinormMTW/AWM-CSA-HArULStyle1015/1028/1283/1284
CC-singlecorePUr-390
CC-halogen-freesinglecoreH05Z-K/H07Z-K-871
CC-earthingropeESY-356
CC-earthingropeESUY-357
CC-earthingropeX00V3-D-354

495
496
498
500
502
504
506
508
508
508

Spiral Cables
CC-SpiralcablePUr-997

240

Appendix

511

Abbreviation Overview

520

Mounting instructions

548

European Directives WEEE, RoHS, ElektroG & Reach

556

General Conditions of Sale

557

TP=paired
EMC=electromagneticcompatibility
* formobilepowersupplychainapplication
Schleppflex isaregisteredtrademarkofCC-ConCabkabelgmbh
Note:

ConCabisnotresponsibleforanyerrorsinprint,articlenumbers,copperweight,etc.containedinthiscatalogue.

Nopartofthispublicationmaybereproducedortransmittedinformorbyanymeanswithoutpermissioninwritingfrom
ConCabkabelgmbh.

ConCabkabelconnectstheworld

15

DESINA inanabbreviationforDistributEd and Standardized INstAllationtechnologyfor


machinetoolsandmanufacturingsystems.DESINA isaspecificationforstandardisingelectrical,
hydraulicandpneumaticcomponentsandtheirinterconnectionononecommonplatformfor
CNC-controlledmachinetoolsandmanufacturingsystems.TheAssociationofGermanMachine
ToolFactories(VDW)contractedaresearchanddevelopmentprojectInstallationTechnologyin
MachineTools,carriedoutbytheInstituteforMachineToolsandbusinessmanagement(iwb)at
theTechnicalUniversityofMunich.Theworkinggroupassistingtheprojectconsistedof
representativesfromthecarmanufacturingindustryaswellasthecomponentsuppliersand
machinetoolindustries.Thespecificationalsoincludesthestandardisationforoutersheath
coloursoncablesforspecificapplications.ConCabkabelisaspecificiedsupplierofDESINA
conformingproductsandcanbefoundontheinternetsiteofDESINA.

16

ConCabkabelconnectstheworld

CC-Cables:

Page

ServoCablesShielded

CC-Schleppflex PVC-C-573
CC-ServoPVC-C-577
CC-ServoPVC-C-585
CC-ServoflexPUr-C-581
CC-ServoflexPUr-C-582
CC-ServoflexPUr-C-583
CC-ServoflexPUr-C-584
CC-ServoflexPUr-C-592

48
130
108
118
142
122
146
148

FeedbackandSensorCables

CC-PVC-C-251
CC-PUr-C-181
CC-PUr-C-281
CC-Ether-BUS-C-(TP)-471
CC-Schleppflex-Ether-BUS-C-(TP)-471

96
100
102
174
175

CC-BUSPVC-C-93
CC-LONBUSC-935
CC-BUSCAN-PVC-C-93
CC-BUSSchleppflexPUr-C-94
CC-BUSSchleppflexCAN-PUr-C-94
CC-BUSSchleppflex Hybrid-PUr-931

158
163
166
160
167
171

Bus-/Fiberoptic-Cables

Sensor-ActuatorCables

CC-Schleppflex Sensor-ActuatorPUr-567 155


CC-BUSAS-Interface,yellow
168

PowerCablesnotShielded

CC-ServoPVC-586
CC-ServoflexPUr-580
CC-ServoflexPUr-588
CC-BUSAS-Interface,black

106
114
126
168

CC-Schleppflex PVC-570 and


CC-Schleppflex PUr-575 and
CC-ControlcableH05VV5-F-115
CC-ControlcableH-1110halogen-free
CC-ControlcableH-1111halogen-free
CC-ZweinormPVC-167 and
CC-ZweinormPUr-141 and

40
56
210
247
252
214
230

ControlCables

Specialneeds,differentdimensionsordifferentoutersheathcoloursuponrequest.
Forinstallationinstructionspleaseseepage548.

ConCabkabelconnectstheworld

17

18

ConCabkabelconnectstheworld

Register
Robust cable, power chain cable, servo-, sensor and
feedback cable, robotic cable, cable for Fieldbus

Page 20 - 177

PVC control cable, shielded and unshielded, with and


without approvals, tray cable

Page 180 - 225

PUR control cable, shielded and unshielded, with and


without approvals; halogen-free cable, spiral cable

Page 228 - 253

Data cable, shielded and unshielded


Halogen-free data cable

Page 256 - 303

Computer cable

Page 306 - 326

LAN-(CAT), coax-, monitor-, LWL- and fibre optic cable

Page 328 - 347

Telephone and fire alarm cable

Page 350 - 369

Compensating cable
Rubber cable

Page 371 - 391

Lift cable

Page 393 - 413

Temperature resistant cable


Solar cable

Page 416 - 462

Power cable

Page 464 - 489

Single core, with and without approvals


Earthing rope

Page 492 - 509

ConCabkabel connects the world


19

CC-control cable robust-JZ-500


High mechanical and microbes resistance,
halogen-free, 300/500V

ConCab kabel Mainhardt 500 25 G 0,75

Technical data
The flexible CC-control cable Robust - JZ 500 is
suitable as a guiding, controlling and measuring cable
especially when free unrestricted movement is
required. It can be used in the construction of
machine tools, plant and appliances, as well as in
laundry and car-wash industry, chemical industry,
sewage plants and compost works. Furthermore, it is
suitable to be used in the food- and beverage industry
especially in the manufacturing equipment of
milk- and meat products. Due to its robust
characteristics, it is suitable for application where the
cable is exposed to mineral, vegetable-, animal- or
synthetic oil, fat or wax. The UV-resistant outer sheath,
is extremely robust and weather resistant and can be
used in cold and warm waters and ditergent-waters.

Construction
Fine strands of bare copper wire, TPE core insulation,
cores black with consecutive white numbering.
3 cores or more with green/yellow protective
conductor in the outer layer. Cores twisted in layers.
TPE outer sheath, halogen-free, UV-resistant and
resistant to hydrolisis and microbes, flame retardant
and self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp.EN 50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).

20

Rated voltage:
DIN/VDE IEC 300/500 V

Test voltage:
3000 V

Conductor stranding:
fine copper strands,
acc. to VDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-50C to +80C
-40C to +80C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0250, 0281

ConCab kabel connects the world

Part-No.

Weight
Outer
diameter
approx.

No. of
cores
+
crosssection

Copper
weight
kg/km

mm

kg/km

500 0005 002


500 1005 003
500 0005 003
500 1005 004
500 0005 004
500 0005 005
500 1005 005
500 1005 007
500 0005 007
500 0005 010
500 0005 012
500 0005 018
500 0005 025

2 X 0,5
3 X 0,5
3 G 0,5
4 X 0,5
4 G 0,5
5 X 0,5
5 G 0,5
7 X 0,5
7 G 0,5
10 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

10,0
15,0
15,0
19,2
19,2
24,0
24,0
33,6
33,6
48,0
58,0
86,4
120,0

5,0
5,3
5,3
5,7
5,7
6,2
6,2
6,7
6,7
8,4
8,8
10,2
12,5

27
33
33
41
41
49
49
64
64
92
106
151
210

500 0007 002


500 1007 003
500 0007 003
500 1007 004
500 0007 004
500 1007 005
500 0007 005
500 1007 007
500 0007 007
500 0007 012
500 0007 018
500 0007 025

2 X 0,75
3 X 0,75
3 G 0,75
4 X 0,75
4 G 0,75
5 X 0,75
5 G 0,75
7 X 0,75
7 G 0,75
12 G0,75
18 G0,75
25 G0,75

14,4
21,6
21,6
28,8
28,8
36,0
36,0
50,0
50,0
86,0
130,0
180,0

5,4
5,7
5,7
6,2
6,2
6,8
6,8
7,3
7,3
9,7
11,4
13,8

35
43
43
49
49
66
66
85
85
144
208
288

500 0010 002


500 1010 003
500 0010 003
500 1010 004
500 0010 004
500 1010 005
500 0010 005
500 0010 007
500 0010 010
500 0010 012
500 0010 018
500 0010 025

2 X 1,0
3 X 1,0
3 G 1,0
4 X 1,0
4 G 1,0
5 X 1,0
5 G 1,0
7 G 1,0
10 G 1,0
12 G1,0
18 G1,0
25 G1,0

19,2
28,8
28,8
38,4
38,4
48,0
48,0
67,0
96,0
115,0
173,0
240,0

5,8
6,2
6,2
6,7
6,7
7,3
7,3
8,1
10,2
10,5
12,5
15,2

42
49
49
63
63
78
78
107
154
178
262
357

Part-No.

No. of
cores
+
crosssection

Copper
weight
kg/km

mm

kg/km

500 0015 002


500 1015 003
500 0015 003
500 1015 004
500 0015 004
500 1015 005
500 0015 005
500 1015 007
500 0015 007
500 0015 010
500 0015 012
500 0015 018
500 0015 025

2 X 1,5
3 X 1,5
3 G 1,5
4 X 1,5
4 G1,5
5 X 1,5
5 G 1,5
7 X 1,5
7 G 1,5
10 G 1,5
12 G 1,5
18 G1,5
25 G 1,5

29,0
43,0
43,0
58,0
58,0
72,0
72,0
101,0
101,0
143,0
173,0
259,0
360,0

6,5
6,9
6,9
7,6
7,6
8,3
8,3
9,0
9,0
11,4
12,0
14,2
17,4

56
72
72
91
91
108
108
149
149
215
234
369
510

500 0025 002


500 0025 003
500 0025 004
500 0025 005
500 0025 007
500 0025 012

2 X 2,5
3 G 2,5
4 G2,5
5 G 2,5
7 G2,5
12 G2,5

48,0
72,0
96,0
120,0
168,0
288,0

7,7
8,1
8,8
9,8
10,7
14,2

86
115
131
178
241
405

500 0040 003


500 0040 004
500 0040 005
500 0040 007

3 G4
4 G4
5 G4
7 G4

115,5
157,0
192,0
269,0

10,0
11,1
12,2
13,3

180
228
280
377

500 0060 004


500 0060 005

4 G6
5 G6

230,0
288,0

13,0
14,3

332
407

500 0100 004


500 0100 005

4 G10
5 G10

384,0
480,0

16,4
18,4

541
620

500 0160 004

4 G16

614,4

19,6

806

500 025 004

4 G25

960,0

24,2

1218

500 0350 004

4 G35

1344,0

28,0

1658

ConCab kabel connects the world

Outer
Weight
diameter
approx.

21

CC-control cable robust-JB/JZ-501


High mechanical and microbes resistance,
halogen-free, 450/750V

ConCab kabel Mainhardt 501 12 G 1

Technical data
The flexible CC-control cable Robust - JB/JZ 501 is
suitable as a guiding, controlling and measuring cable
especially when free unrestricted movement is required.
It can be used in the construction of machine tools, plant
and appliances, as well as in laundry and car-wash industry, chemical industry, sewage plants and compost works.
Furthermore, it is suitable to be used in the food- and
beverage industry especially in the manufacturing
equipment of milk- and meat products.
Due to its robust characteristics, it is suitable for
application where the cable is exposed to mineral,
vegetable-, animal- or synthetic oil, fat or wax.
The UV-resistant outer sheath, is extremely robust and
weather resistant and can be used in cold and warm
waters and ditergent-waters.

Construction
Fine strands of bare copper wire, TPE core insulation,
cores coloured acc. to DIN VDE 0293 part 308. 6 cores
or more are black with consecutive white
numbering. Cores twisted in layers. TPE outer
sheath, halogen-free, UV-resistant, non-adhesive and
resistant to hydrolisis and microbes, flame
retardant and self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp.EN 50265-2-1 and
IEC 60332-1). Colour black (RAL 9005).

22

Rated voltage:
DIN/VDE IEC 450/750 V

Test voltage:
4000 V

Conductor stranding:
fine copper strands,
acc. to VDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-50C to +80C
-40C to +80C

fixed installation:
flexible application:

4 X cable diameter
10 X cable diameter

Bending radius:

Approvals:
acc. to DINVDE 0250, 0281

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Weight
Outer
diameter
approx.

kg/km

mm

kg/km

501 0010 002


501 1010 003
501 0010 003
501 1010 004
501 0010 004
501 1010 005
501 0010 005
501 0010 007
501 0010 010
501 0010 012
501 0010 018
501 0010 025

2 X 1,0
3 X 1,0
3 G 1,0
4 X 1,0
4 G 1,0
5 X 1,0
5 G 1,0
7 G 1,0
10 G 1,0
12 G1,0
18 G1,0
25 G1,0

19,2
28,8
28,8
38,4
38,4
48,0
48,0
67,0
96,0
115,0
173,0
240,0

7,8
6,2
8,2
6,7
6,7
7,3
10,0
8,1
10,2
10,5
12,5
15,2

66
49
79
63
63
78
113
107
154
178
262
357

501 0015 002


501 0015 003
501 0015 004
501 0015 005
501 0015 007

2 X 1,5
3 G 1,5
4 G1,5
5 G 1,5
7 G 1,5

29,0
43,0
58,0
72,0
101,0

8,4
8,9
9,9
10,8
13,1

78
96
122
146
208

501 0025 002


501 0025 003
501 0025 004
501 0025 005
501 0025 007

2 X 2,5
3 G 2,5
4 G2,5
5 G 2,5
7 G2,5

48,0
72,0
96,0
120,0
168,0

9,6
10,2
11,3
12,3
14,7

114
144
181
222
312

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
Weight
diameter
approx.

kg/km

mm

kg/km

501 0040 003


501 0040 004
501 0040 005

3 G4
4 G4
5 G4

115,5
157,0
192,0

12,1
13,4
14,7

215
273
333

501 0060 004


501 0060 005

4 G6
5 G6

230,0
288,0

15,1
16,5

378
463

501 0100 004


501 0100 005

4 G10
5 G10

384,0
480,0

18,9
21,0

570
770

501 0160 004

4 G16

614,4

22,0

885

501 0160 005

5 G 16

768,0

22,4

1100

501 025 004

4 G25

960,0

26,1

1365

501 0350 004

4 G35

1344,0

29,9

1775

501 0500 004

4 G 50

1920,0

34,4

3454

Up to five cores, coloured acc. to DINVDE 0293, part 308 -JB


Six cores or more black with consecutive white numbering - JZ

ConCab kabel connects the world

23

CC-control cable robust-C-JZ-502


High mechanical and microbes resistance,
halogen-free, shielded 300/500V

ConCab kabel Mainhardt 502 18 G 0,75

The flexible CC-control cable Robust-C- JZ 502


shielded, is suitable as a guiding, controlling and
measuring cable especially when free unrestricted
movement is required. It can be used in the
construction of machine tools, plant and appliances, as
well as in laundry and car-wash industry, chemical
industry, sewage plants and compost works.
Furthermore, it is suitable to be used in the food- and
beverage industry especially in the manufacturing
equipment of milk- and meat products. Due to its
robust characteristics, it is suitable for application
where the cable is exposed to mineral, vegetable-, animal- or synthetic oil, fat or wax. The UV-resistant
outer sheath, is extremely robust and weather resistant
and can be used in cold and warm waters and
ditergent-waters. The overall copper shield ensures
exact data transmission and protects the cable against
electromagnetic disturbances and influences.

Construction
Fine strands of bare copper wire, TPE core insulation,
cores are black with consecutive white numbering.
Cores twisted in layers, overall tinned copper shield.
TPE outer sheath, halogen-free, UV-resistant and
resistant to hydrolisis and microbes,
nonadhesive, flame, retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.EN
50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).

24

Technical data
Rated voltage:
DIN/VDE IEC 300/500 V

Test voltage:
3000 V

Conductor stranding:
fine copper strands,
acc. to VDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-50C to +80C
-40C to +80C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281

ConCab kabel connects the world

Part-No.

Weight
Outer
diameter
approx.

No. of
cores
+
crosssection

Copper
weight
kg/km

mm

kg/km

502 0005 002


502 1005 003
502 0005 003
502 1005 004
502 0005 004
502 0005 005
502 1005 005
502 1005 007
502 0005 007
502 0005 012
502 0005 018
502 0005 025

2 X 0,5
3 X 0,5
3 G 0,5
4 X 0,5
4 G 0,5
5 X 0,5
5 G 0,5
7 X 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

36,0
43,0
43,0
49,0
49,0
57,0
57,0
69,0
69,0
104,0
141,0
211,0

5,7
6,0
6,0
6,5
6,5
6,9
6,9
7,6
7,6
9,8
11,3
13,4

42
52
52
59
59
68
68
85
85
136
189
265

502 0007 002


502 1007 003
502 0007 003
502 1007 004
502 0007 004
502 1007 005
502 0007 005
502 1007 007
502 0007 007
502 0007 012
502 0007 018
502 0007 025

2 X 0,75
3 X 0,75
3 G 0,75
4 X 0,75
4 G 0,75
5 X 0,75
5 G 0,75
7 X 0,75
7 G 0,75
12 G0,75
18 G0,75
25 G0,75

43,0
52,0
52,0
61,0
61,0
72,0
72,0
89,0
89,0
138,0
211,0
280,0

6,2
6,5
6,5
6,9
6,9
7,7
7,7
8,3
8,3
10,6
12,5
14,9

50
60
60
72
72
88
88
110
110
177
247
347

502 0010 002


502 1010 003
502 0010 003
502 1010 004
502 0010 004
502 1010 005
502 0010 005
502 0010 007
502 0010 012
502 0010 018
502 0010 025

2 X 1,0
3 X 1,0
3 G 1,0
4 X 1,0
4 G 1,0
5 X 1,0
5 G 1,0
7 G 1,0
12 G1,0
18 G1,0
25 G1,0

51,0
62,0
62,0
74,0
74,0
88,0
88,0
112,0
185,0
268,0
354,0

6,6
6,9
6,9
7,6
7,6
8,3
8,3
8,9
11,5
13,5
16,1

60
70
70
85
85
103
103
131
213
321
425

Part-No.

No. of
cores
+
crosssection

Copper
weight
kg/km

mm

kg/km

502 0015 002


502 1015 003
502 0015 003
502 1015 004
502 0015 004
502 1015 005
502 0015 005
502 1015 007
502 0015 007
502 0015 012
502 0015 018
502 0015 025

2 X 1,5
3 X 1,5
3 G 1,5
4 X 1,5
4 G1,5
5 X 1,5
5 G 1,5
7 X 1,5
7 G 1,5
12 G 1,5
18 G1,5
25 G 1,5

65,0
82,0
82,0
100,0
100,0
119,0
119,0
154,0
154,0
268,0
373,0
530,0

7,2
7,9
7,9
8,5
8,5
9,2
9,2
9,9
9,9
13,0
15,3
18,5

71
90
90
114
114
136
136
177
177
290
435
579

502 0025 003


502 0025 004
502 0025 005
502 0025 007

3 G 2,5
4 G2,5
5 G 2,5
7 G2,5

118,0
147,0
176,0
253,0

9,0
9,8
10,7
11,7

134
169
207
270

502 0040 004

4 G4

190,0

11,9

258

502 0060 004

4 G6

290,0

13,9

392

502 0100 004

4 G10

458,0

17,6

602

502 0160 004

4 G16

736,6

20,7

928

502 025 004

4 G25

1126,7

25,3

1411

502 0350 004

4 G35

1540,0

29,1

1883

ConCab kabel connects the world

Outer
Weight
diameter
approx.

25

CC-Schleppflex robust-JZ-503
High mechanical and microbes resistance,
high flexible, halogen-free

ConCab kabel Mainhardt 503 18 G 0,75

Technical data
Rated voltage:
DIN/VDE IEC 300/500 V

The high flexible CC-Schleppflex -Robust- JZ 503 is


used as a control cable in power supply chains and in
moving machine parts especially in wet areas of
machine equipment, in laundry and car-wash industry,
chemical industry, sewage plants and compost works.
Furthermore, it is suitable to be used in the food- and
beverage industry especially in the manufacturing
equipment of milk- and meat products. Due to its
robust characteristics, it is suitable for application
where the cable is exposed to mineral,
vegetable-, animal- or synthetic oil, fat or wax.
The UV-resistant outer sheath, is extremely robust
and weather resistant and can be used in cold and
warm waters and ditergent-waters.

Construction
Superfine strands of bare copper wire, TPE core
insulation, cores are black with consecutive white
numbering, cores twisted in layers. TPE outer sheath,
halogen-free, UV-resistant and resistant to hydrolisis
and microbes, non-adhesive, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour black (RAL 9005).

26

Test voltage:
3000 V

Conductor stranding:
fine copper strands,
acc. to VDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-50C to +105C
-40C to +105C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 10 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
Weight
diameter
approx.

kg/km

mm

kg/km

503 0007 003


503 0007 004
503 0007 005
503 0007 007
503 0007 012
503 0007 018
503 0007 025

3 G 0,75
4 G0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G0,75
25 G 0,75

21,6
28,8
36,0
50,4
86,4
129,6
180,0

7,3
7,8
8,7
10,3
12,5
14,6
17,9

51
69
87
127
182
277
421

503 0010 003


503 0010 004
503 0010 005
503 0010 007
503 0010 012
503 0010 018

3 G 1,0
4 G1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G1,0

28,8
38,4
48,0
67,2
115,2
172,8

7,9
8,8
9,5
11,3
13,9
16,3

63
82
105
157
226
345

503 0015 003


503 0015 004
503 0015 005
503 0015 007
503 0015 012
503 0015 018
503 0015 025

3 G 1,5
4 G1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G1,5
25 G 1,5

43,2
57,6
72,0
100,8
172,8
259,2
360,0

9,0
9,7
10,8
13,0
15,8
18,5
22,8

90
118
149
233
322
494
695

503 0025 004


503 0025 005
503 0025 007
503 0025 012

4 G2,5
5 G 2,5
7 G2,5
12 G2,5

96,0
120,0
168,0
288,0

11,1
12,4
14,7
18,1

181
228
329
491

503 0040 004

4 G4

153,6

13,5

261

503 0060 004

4 G6

230,4

15,4

356

503 0100 004

4 G10

384,0

18,4

596

503 0160 004

4 G16

614,4

21,8

910

ConCab kabel connects the world

27

CC-Schleppflex robust-C-JZ-504
High mechanical and microbes resistance,
high flexible, halogen-free, shielded

ConCab kabel Mainhardt 504 18 G 0,75

The high flexible CC-Schleppflex-Robust- C-JZ 504


shielded, is used as a control cable in power supply
chains and in moving machine parts
especially in wet areas of machine equipment, in
laundry and car-wash industry, chemical industry,
sewage plants and compost works. Furthermore, it is
suitable to be used in the food- and beverage
industry especially in the manufacturing equipment of
milk- and meat products. Due to its robust
characteristics, it is suitable for application where the
cable is exposed to mineral, vegetable-,
animal- or synthetic oil, fat or wax. The UV-resistant
outer sheath, is extremely robust and weather resistant
and can be used in cold and warm waters and ditergent-waters. The overall copper shield ensures exact
data transmission and protects the cable against
electromagnetic disturbances and influences.

Construction
Superfine strands of bare copper wire, TPE core
insulation, cores are black with consecutive white
numbering. Cores twisted in layers, inner sheath,
overall tinned copper shield. TPE outer sheath,
halogen-free, UV-resistant and resistant to hydrolisis
and microbes, non-adhesive, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp.EN 50265-2-1 and
IEC 60332-1). Colour black (RAL 9005).

28

Technical data
Rated voltage:
DIN/VDE IEC 300/500 V

Test voltage:
3000 V

Conductor stranding:
fine copper strands,
acc. to DINVDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-50C to +105C
-40C to +105C

Bending radius:
fixed installation: 7,5 X cable diameter
flexible application: 10 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
Weight
diameter
approx.

kg/km

mm

kg/km

504 0007 003


504 0007 004
504 0007 005
504 0007 007
504 0007 012
504 0007 018
504 0007 025

3 G 0,75
4 G0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G0,75
25 G 0,75

49,6
60,9
72,8
107,2
151,5
205,5
299,1

9,8
10,8
11,4
13,5
15,7
18,3
22,2

110
137
160
238
312
448
657

504 0010 003


504 0010 007
504 0010 012

3 G 1,0
7 G 1,0
12 G 1,0

61,1
132,3
189,1

10,8
14,5
17,4

125
278
370

504 0015 003


504 0015 004
504 0015 005
504 0015 007
504 0015 012
504 0015 018
504 0015 025

3 G 1,5
4 G1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G1,5
25 G 1,5

79,8
99,2
129,7
175,2
257,1
378,9
555,5

11,9
13,1
14,0
16,0
19,8
22,8
27,8

163
210
264
370
498
749
1042

504 0025 004


504 0025 005
504 0025 007
504 0025 012

4 G2,5
5 G 2,5
7 G2,5
12 G2,5

161,5
188,3
252,6
406,5

14,3
15,6
18,4
22,4

307
361
512
730

504 0040 004

4 G4

227,3

16,8

412

504 0060 004

4 G6

306,7

19,2

519

504 0100 004

4 G10

513,6

22,7

853

504 0160 004

4 G16

809,6

26,2

1273

ConCab kabel connects the world

29

CC-Schleppflex PVC-570
High flexible data cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-570 18x0,25

Technical data
CC-Schleppflex PVC-570
is used as a data- and signal cable for power supply
chains, sensor technology, computers and
control devices for measurement and control
technology. It can be used in damp and wet areas but
not outdoors. A long service life is achieved by the
special structure and PVC mixture of the cable.

Conductor stranding:
fine copper strands,
acc. to DIN VDE 0295, class 6

Insulation resistance:
min. 100 MOhm X km

Construction

Temperature range:

Superfine bare strands of copper wire, PVC core


insulation, core colours acc. to DIN 47100. Cores
twisted in layers with very short lay lengths, fleece,
PVC outer sheath, extensively resistant to oil and
cooling liquid, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7001).

Bending radius:
10 X cable diameter

Approvals:
acc. to DIN VDE 0281, 0812

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

30

-5C to +70C

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

570 0001 002


570 0001 003
570 0001 004
570 0001 005
570 0001 007
570 0001 010
570 0001 012
570 0001 014
570 0001 018
570 0001 025

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2,8
4,2
5,6
7,0
9,8
14,0
16,8
19,6
25,2
35,0

4,0
4,5
4,8
5,1
6,2
7,2
7,3
7,5
8,0
9,5

23
26
31
35
50
63
71
77
91
125

570 0002 002


570 0002 003
570 0002 004
570 0002 005
570 0002 007
570 0002 010
570 0002 012
570 0002 014
570 0002 018
570 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

5,0
7,5
10,0
12,5
17,5
25,0
30,1
35,0
45,0
62,5

4,5
4,9
5,3
6,2
6,5
8,2
8,3
8,5
9,5
11,0

28
33
40
51
64
84
95
107
130
178

570 0003 002


570 0003 003
570 0003 004
570 0003 005
570 0003 007
570 0003 010
570 0003 012
570 0003 014
570 0003 018
570 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

6,8
10,2
13,6
17,0
23,8
34,0
40,8
47,6
61,2
85,0

5,0
5,7
6,5
7,0
8,0
9,4
9,6
10,0
11,0
13,0

33
43
57
65
85
117
133
151
182
250

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

31

CC-Schleppflex PVC-570
High flexible data cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt - 570 18x0,34 E 172073 cr AWM STYLE 2464 300 V 80C

Technical data
Conductor stranding:
CC-Schleppflex PVC-570 UL/CSA
is used as a data- and signal cable for power
supply chains, sensor technology, computers and
control devices for measurement and control
technology. It can be used in damp and wet areas but
not outdoors. A long service life is achieved by the
special structure and PVC mixture of the cable.

Construction
Superfine bare strands of copper wire, PVC core
insulation, core colours acc. to DIN 47100. Cores
twisted in layers with very short lay lengths, fleece,
PVC outer sheath, extensively resistant to oil and
cooling liquid, flame retardant and self extinguishing
(acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Insulation resistance:
min. 100 MOhm X km

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +80C

Bending radius:
7,5 X cable diameter

Approvals:
acc. to DINVDE 0281, 0812
UL: Style 2464
CSA: C 22.2 N 210.2-M90 FT1

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt) VDE / UL, CSA:

300

300

300

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

32

fine copper strands,


acc. to DIN VDE 0295, class 6

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

570 26 02
570 26 03
570 26 04
570 26 05
570 26 07
570 26 10
570 26 12
570 26 14
570 26 18
570 26 25

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2 X AWG 26
3 X AWG 26
4 X AWG 26
5 X AWG 26
7 X AWG 26
10 X AWG 26
12 X AWG 26
14 X AWG 26
18 X AWG 26
25 X AWG 26

2,8
4,2
5,6
7,0
9,9
14,1
16,9
19,7
25,3
35,2

3,5
3,7
3,9
4,2
4,6
5,3
5,6
5,7
6,2
7,3

15
16
19
22
29
35
40
44
55
77

570 24 02
570 24 03
570 24 04
570 24 05
570 24 07
570 24 10
570 24 12
570 24 14
570 24 18
570 24 25

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

2 X AWG 24
3 X AWG 24
4 X AWG 24
5 X AWG 24
7 X AWG 24
10 X AWG 24
12 X AWG 24
14 X AWG 24
18 X AWG 24
25 X AWG 24

5,0
7,5
10,0
12,5
17,6
25,1
30,1
35,1
45,1
62,7

3,9
4,1
4,5
4,8
5,3
6,1
6,3
6,9
7,9
8,6

20
21
25
30
40
50
57
66
83
114

570 22 02
570 22 03
570 22 04
570 22 05
570 22 07
570 22 10
570 22 12
570 22 14
570 22 18
570 22 25

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

2 X AWG 22
3 X AWG 22
4 X AWG 22
5 X AWG 22
7 X AWG 22
10 X AWG 22
12 X AWG 22
14 X AWG 22
18 X AWG 22
25 X AWG 22

6,6
9,9
13,2
16,5
23,1
33,0
39,6
46,2
59,4
82,5

4,1
4,4
4,7
5,0
5,6
6,8
7,0
7,1
7,8
9,6

23
25
30
35
48
62
71
80
100
148

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

33

CC-Schleppflex PVC-570
High flexible control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-570 18G0,75

Technical data
Rated voltage:
300/500 V
CC-Schleppflex PVC-570
has been developed as a control cable for use in
power supply chains. The increasing demand in
industrial automation requires cables with narrow
bending radius. CC-Schleppflex meets this
requirement due to its praxis-oriented development.
A long service life is achieved by the special
structure and compounds of the cable. It can be used
in damp and wet areas but not outdoors.

Test voltage:
3000 V

Conductor stranding:
superfine copper strands,
acc. to DIN VDE 0295, class 6

Insulation resistance:
min. 100 MOhm X km

Construction
Superfine strands of bare copper wire,
PVC core insulation, cores black with
consecutive white numbering. Cables with 3 cores or
more contain a green/yellow protective conductor in
the outer layer. Cores twisted in layers in very short
lay lengths, fleece. PVC outer sheath, extensively
resistant to oil and cooling liquid, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

34

Temperature range:
fixed installation:
flexible application:

-40C to +70C
-5C to +70C

Bending radius:
7,5 X cable diameter

Approvals:
acc. to DINVDE 0245, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

570 0005 002


570 0005 003
570 0005 004
570 0005 005
570 0005 007
570 0005 012
570 0005 014
570 0005 018
570 0005 025
570 0005 030
570 0005 034
570 0005 042
570 0005 050

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
14 G 0,5
18 G 0,5
25 G 0,5
30 G 0,5
34 G 0,5
42 G 0,5
50 G 0,5

9,6
14,4
19,2
24,0
34,0
58,0
67,0
86,4
120,0
144,0
163,2
202,0
240,0

5,3
5,6
6,4
7,1
8,3
10,0
10,6
11,7
13,7
14,9
16,1
18,3
18,6

36
44
53
64
95
129
144
194
278
313
358
432
527

570 0007 002


570 0007 003
570 0007 004
570 0007 005
570 0007 007
570 0007 012
570 0007 016
570 0007 018
570 0007 025
570 0007 030
570 0007 034
570 0007 042
570 0007 050

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
30 G 0,75
34 G 0,75
42 G 0,75
50 G 0,75

14,4
21,6
29,0
36,0
50,0
86,0
115,2
130,0
180,0
216,0
245,0
302,0
360,0

5,9
6,2
7,2
7,9
9,3
11,2
12,5
13,2
15,9
17,3
18,5
19,0
21,5

43
51
66
84
105
180
251
260
340
398
443
510
587

570 0010 002


570 0010 003
570 0010 004
570 0010 005
570 0010 007
570 0010 012
570 0010 014

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
14 G 1,0

19,2
29,0
38,4
48,0
67,0
115,0
134,0

7,1
7,4
8,1
9,3
11,1
12,8
13,6

58
74
89
100
129
241
259

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

570 0010 016


570 0010 018
570 0010 025
570 0010 034
570 0010 041
570 0010 050
570 0010 065

16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
65 G 1,0

153,0
173,0
240,0
326,0
394,0
480,0
624,0

14,4
15,2
18,3
21,3
23,1
24,8
28,9

288
325
481
635
805
879
1221

570 0015 002


570 0015 003
570 0015 004
570 0015 005
570 0015 007
570 0015 012
570 0015 014
570 0015 016
570 0015 018
570 0015 025
570 0015 030
570 0015 034
570 0015 041
570 0015 042
570 0015 050
570 0015 061
570 0015 065

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
14 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
30 G 1,5
34 G 1,5
41 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0
203,0
232,0
257,0
357,0
429,0
490,0
591,0
605,0
720,0
878,0
936,0

7,5
7,9
8,8
9,9
11,8
13,6
14,2
15,3
16,2
19,9
21,0
22,7
24,7
24,7
26,5
28,0
31,0

67
83
106
134
173
313
350
426
525
684
799
891
1061
1075
1325
1578
1672

570 0025 003


570 0025 004
570 0025 005
570 0025 007
570 0025 012
570 0025 014
570 0025 018
570 0025 025

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
14 G 2,5
18 G 2,5
25 G 2,5

72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

10,0
11,1
12,3
15,5
17,6
18,6
21,1
25,0

132
195
242
346
516
586
824
988

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

35

CC-Schleppflex PVC-570
High flexible control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-570 3G6

Technical data
Rated voltage:
300/500 V
CC-Schleppflex PVC-570 has been developed as a
control cable for use in power supply chains.
The increasing demand in industrial automation
requires cables with narrow bending radius.
CC-Schleppflex meets this requirement due to its
pratice-oriented development. A long service life is
achieved by the special structure and compounds of
the cable. It can be used in damp and wet areas but
not outdoors.

36

Test voltage:
3000 V

Conductor stranding:
superfine copper strands,
acc. to DINVDE 0295, class 6

Insulation resistance:

Construction

min. 100 MOhm X km

Superfine strands of bare copper wire,


PVC core insulation, cores black with consecutive
white numbering. Cables with 3 cores or more
contain a green/yellow protective conductor in the
outer layer. Cores twisted in layers in very short lay
lengths, fleece. PVC outer sheath, extensively
resistant to oil and cooling liquid, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7001).

Temperature range:
fixed installation:
flexible application:

-40C to +70C
-5C to +70C

Bending radius:
7,5 X cable diameter

Approvals:
acc. to DINVDE 0245, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

570 0040 003


570 0040 004
570 0040 005
570 0040 007

3G4
4G4
5G4
7G4

115,2
154,0
192,0
269,0

12,9
13,9
15,6
18,1

228
283
377
516

570 0060 99
570 0060 003
570 0060 004
570 0060 005
570 0060 007

1G6
3G6
4G6
5G6
7G6

57,6
173,0
230,0
288,0
403,0

6,6
14,2
16,5
18,9
21,8

65
334
505
613
846

570 0100 003


570 0100 004
570 0100 005
570 0100 007

3 G 10
4 G 10
5 G 10
7 G 10

288,0
384,0
480,0
672,0

18,5
20,8
22,7
24,1

624
756
939
1236

570 0160 004


570 0160 005

4 G 16
5 G 16

614,0
768,0

24,2
27,3

1116
1408

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

37

CC-Schleppflex PVC-570
High flexible single core cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 570 E 172073 c STYLE 10107 600V 90C

Technical data
Rated voltage:
DIN VDE/IEC 600/1000 V
UL/CSA 600 V

Test voltage:
4000 V

Conductor stranding:

CC-Schleppflex PVC-570 UL/CSA single core,


has been developed as a control cable for use in
power supply chains. The increasing demand in
industrial automation requires cables with narrow
bending radius. CC-Schleppflex meets this
requirement due to its practice-oriented
development. A long service life is achieved by the
special structure and compounds of the cable.
It can be used in damp and wet areas.

Construction
Superfine strands of bare copper wire,
PVC black or green/yellow core insulation.
PVC outer sheath, UV resistant, extensively
resistant to oil and cooling liquid, flame retardant and
self-extinguishing (acc. to DIN VDE 0482, part 2652-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour black (RAL 9005).

38

bare superfine copper strands,


acc. to UL 1581, Tab. 20.1
acc. toDIN VDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-40C to +90C
-5C to +90C

Bending radius:
fixed installation: 3 X cable diameter
flexible application: 7,5 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281
UL: Style 10107
CSA:AWM I A/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

AWG

+
crosssection

Copper
weight

Outer diameter
approx.

Weight

kg/km

mm

kg/km

570 0801 00
570 0801 99

1 X 10
1 G 10

AWG 8
AWG 8

96
96

9,0
9,0

180
180

570 0601 00
570 0601 99

1 X 16
1 G 16

AWG 6
AWG 6

153
153

10,1
10,1

221
221

570 0401 00
570 0401 99

1 X 25
1 G 25

AWG 4
AWG 4

240
240

11,3
11,3

336
336

570 0201 00
570 0201 99

1 X 35
1 G 35

AWG 2
AWG 2

336
336

14,5
14,5

500
500

570 01001 00
570 01001 99

1 X 50
1 G 50

AWG 1/0
AWG 1/0

480
480

16,3
16,3

720
720

570 02001 00
570 02001 99

1 X 70
1 G 70

AWG 2/0
AWG 2/0

672
672

17,5
17,5

850
850

570 03001 00
570 03001 99

1 X 95
1 G 95

AWG 3/0
AWG 3/0

912
912

19,6
19,6

1100
1100

570 04001 00
570 04001 99

1 X 120
1 G 120

AWG 4/0
AWG 4/0

1152
1152

23,0
23,0

1420
1420

570 30001 00
570 30001 99

1 X 150
1 G 150

MCM 300
MCM 300

1440
1440

25,6
25,6

1725
1725

570 35001 00
570 35001 99

1 X 185
1 G 185

MCM 350
MCM 350

1776
1776

28,7
28,7

2315
2315

570 45001 00
570 45001 99

1 X 240
1 G 240

MCM 450
MCM 450

2304
2304

32,8
32,8

2920
2920

570 50001 00
570 50001 99

1 X 300
1 G 300

MCM 500
MCM 500

2880
2880

35,1
35,1

3500
3500

The metrical size is being followed


PUR version please refer to page 124

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

39

CC-Schleppflex PVC-570
High flexible control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 570 - 18G1,5 E 172073 c STYLE 2587 AWM 600V 90C

Technical data
Rated voltage:
DIN VDE/IEC 600/1000 V
UL/CSA 600 V

Test voltage:
CC-Schleppflex PVC-570 UL/CSA
has been developed as a control cable for use in
power supply chains. The increasing demand in
industrial automation requires cables with narrow
bending radius. CC-Schleppflex meets this
requirement due to its practice-oriented development.
A long service life is achieved by the special structure
and compounds of the cable. It can be used in damp
and wet areas.

4000 V

Conductor stranding:
superfine copper strands,
acc. to DIN VDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Construction
Superfine strands of bare copper wire,
PVC core insulation, core colours are black with
consecutive white numbering. Cables with 3 cores or
more contain a green/yellow protective conductor in
the outer layer. Cores twisted in layers in very short
lay lengths, fleece. PVC outer sheath, UV resistant,
extensively resistant to oil and cooling liquid, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1 and IEC
60332-1). Colour black (RAL 9005).
Red or blue core colours upon request.

40

Temperature range:
fixed installation:
flexible application:

-40C to +90C
-5C to +90C

Bending radius:
7,5 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281
UL: Style 2587
CSA:AWM I A/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

570 20 03
570 20 04
570 20 05
570 20 07
570 20 12
570 20 18
570 20 25
570 19 02
570 19 03
570 19 04
570 19 05
570 19 07
570 19 12
570 19 16
570 19 18
570 19 25
570 18 02
570 18 03
570 18 04
570 18 05
570 18 07
570 18 12
570 18 16
570 18 18
570 18 25
570 18 34
570 18 41
570 18 50
570 16 02
570 16 03
570 16 04
570 16 05
570 16 07
570 16 12
570 16 16
570 16 18
570 16 25
570 16 34
570 16 42
570 16 50
570 14 03
570 14 04
570 14 05
570 14 07
570 14 12
570 12 03
570 12 04
570 12 05
570 12 07
570 10 04
570 08 04
570 06 04

No. of cores

No. of cores

+
crosssection

+
AWG

kg/km

mm

kg/km

3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
3 G 4,0
4 G 4,0
5 G 4,0
7 G 4,0
4 G 6,0
4 G 10,0
4 G 16,0

3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20
2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
12 X AWG 19
16 X AWG 19
18 X AWG 19
25 X AWG 19
2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
16 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
50 X AWG 18
2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
16 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
42 X AWG 16
50 X AWG 16
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
12 X AWG 14
3 X AWG 12
4 X AWG 12
5 X AWG 12
7 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6

14,4
19,2
24,0
34,0
58,0
86,4
120,0
14,4
21,6
29,0
36,0
50,0
86,0
116,0
130,0
180,0
19,2
29,0
38,4
48,0
67,0
115,0
145,0
173,0
240,0
326,0
393,0
480,0
29,0
43,2
57,6
72,0
100,8
172,8
230,0
259,2
360,0
489,6
605,0
720,0
72,0
96,0
120,0
168,0
288,0
115,2
153,6
192,0
268,8
230,4
384,0
614,4

6,3
6,8
7,4
8,6
10,7
12,8
15,2
6,4
6,8
7,4
8,0
9,4
11,5
12,7
13,6
16,4
6,9
7,2
7,9
8,6
10,0
12,2
14,0
14,8
17,8
20,0
22,0
23,8
7,3
7,7
8,4
9,2
10,8
13,6
15,1
16,6
19,2
21,6
24,3
25,8
8,7
9,2
10,1
12,0
15,7
11,7
12,8
14,4
17,7
14,8
18,9
21,2

52
67
82
121
170
256
357
62
69
88
110
155
220
300
330
470
75
81
97
118
177
265
320
380
530
722
920
1190
67
93
125
155
228
337
433
513
712
965
1185
1420
165
200
240
350
650
255
372
389
505
631
800
1032

Copper
weight

Outer dia- Weight


meter
approx.

41

CC-Schleppflex PVC-C-573
High flexible data cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-573 120,14

CC-Schleppflex PVC-C-573 shielded with PVC outer


sheath is used as a data- and signal cable in power
supply chains, sensor technology, computers and for
control devices of instrument and control engineering.
It can be used in damp and wet areas but not
outdoors. The overall copper shield ensures exact
data transmission and protects the cable against
electromagnetic disturbances and influences. Along
service life is achieved by the special structure and
PVC mixture of the CC-Schleppflex.

Technical data
Conductor stranding:
superfine copper strands,
acc. to DINVDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, core colours acc. to DIN47100,
cores twisted in layers in short lay lengths, fleece.
Tinned copper shield. PVC outer sheath, extensively
resistant to oil and cooling liquid, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

-40C to +70C
-5C to +70C

Bending radius:
7,5 X cable diameter

Approvals:
acc. to DINVDE 0250, 0812

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

42

Temperature range:
fixed installation:
flexible application:

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

573 0001 002


573 0001 003
573 0001 004
573 0001 005
573 0001 007
573 0001 010
573 0001 012
573 0001 014
573 0001 018
573 0001 025

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

11,4
14,3
15,4
18,5
27,9
40,1
43,0
45,8
54,4
68,8

5,0
5,1
5,3
5,8
6,8
7,7
7,9
8,1
9,0
10,7

31
35
43
48
69
89
99
108
125
168

573 0002 002


573 0002 003
573 0002 004
573 0002 005
573 0002 007
573 0002 010
573 0002 012
573 0002 014
573 0002 018
573 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

15,1
18,6
21,5
31,4
39,9
53,5
58,7
64,8
79,2
103,0

5,4
5,7
6,1
6,7
7,6
8,8
9,0
9,2
9,9
12,0

40
44
54
69
91
117
131
144
163
218

573 0003 002


573 0003 003
573 0003 004
573 0003 005
573 0003 007
573 0003 010
573 0003 012
573 0003 014
573 0003 018
573 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

16,4
28,2
35,4
40,0
51,9
68,2
77,5
86,7
100,2
153,1

6,0
6,3
6,4
7,5
8,5
10,5
10,7
10,9
11,5
13,3

48
65
78
87
121
161
180
199
218
335

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

43

CC-Schleppflex PVC-C-573
High flexible data cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-573 12 x 0,25 E172073 c STYLE 2464 300V 80C

CC-Schleppflex PVC-C-573 shielded UL/CSA with


PVC outer sheath is used as a data- and signal cable
in power supply chains, sensor technology, computers
and for control devices of instrument and control
engineering. It can be used in damp and wet areas but
not outdoors. The overall copper shield ensures exact
data transmission and protects the cable against
electromagnetic disturbances and influences. Along
service life is achieved by the special structure and
PVC mixture of the CC-Schleppflex.

Construction
Superfine strands of bare copper wire, PVC core
insulation, core colours acc. to DIN47100, cores
twisted in layers in short lay lengths, fleece. Tinned
copper shield. PVC outer sheath, extensively resistant
to oil and cooling liquid, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7001).

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0281, 0812


UL: 2464
CSA: C 22.2 N 210.2-M90 FT1

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt) VDE / UL, CSA:

300

300

300

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

44

Technical data

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

573 26 02
573 26 03
573 26 04
573 26 05
573 26 07
573 26 10
573 26 12
573 26 14
573 26 18
573 26 25

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2 X AWG 26
3 X AWG 26
4 X AWG 26
5 X AWG 26
7 X AWG 26
10 X AWG 26
12 X AWG 26
14 X AWG 26
18 X AWG 26
25 X AWG 26

8,5
10,5
12,5
14,5
19,0
25,0
28,0
31,5
38,5
52,0

3,9
4,0
4,2
4,5
5,0
5,8
5,9
6,3
6,7
7,7

22
24
27
31
36
48
52
58
71
95

573 24 02
573 24 03
573 24 04
573 24 05
573 24 07
573 24 10
573 24 12
573 24 14
573 24 18
573 24 25

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

2 X AWG 24
3 X AWG 24
4 X AWG 24
5 X AWG 24
7 X AWG 24
10 X AWG 24
12 X AWG 24
14 X AWG 24
18 X AWG 24
25 X AWG 24

11,7
14,7
18,0
21,4
28,1
37,9
43,4
49,2
61,0
86,4

4,4
4,6
4,8
5,2
5,8
6,9
7,0
7,3
7,9
9,5

28
30
35
40
52
66
73
82
100
148

573 22 02
573 22 03
573 22 04
573 22 05
573 22 07
573 22 10
573 22 12
573 22 14
573 22 18
573 22 25

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

2 X AWG 22
3 X AWG 22
4 X AWG 22
5 X AWG 22
7 X AWG 22
10 X AWG 22
12 X AWG 22
14 X AWG 22
18 X AWG 22
25 X AWG 22

13,8
17,6
21,7
26,0
34,4
46,8
53,9
61,3
80,8
108,7

4,6
4,8
5,1
5,4
6,2
7,3
7,4
7,7
8,3
10,1

31
34
39
46
61
77
86
97
124
176

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

45

CC-Schleppflex PVC-C-573
High flexible control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-573 18G0,75

CC-Schleppflex PVC-C-573 shielded with PVC outer


sheath, is used as a control cable in mobile power
supply chains, sensor technology, computers and for
control devices of instrument and control engineering.
It can be used in damp and wet areas but not
outdoors. The overall copper shield ensures exact
data transmission and protects the cable against
electromagnetic disturbances and influences. Along
service life is achieved by the special structure and
PVC mixture of CC-Schleppflex.

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, cores are black with consecutive
white numbering. Cables with 3 cores or more
contain a green/yellow protective conductor in the
outer layer. Cores twisted in layers in short lay
lengths, fleece. PVC inner sheath, tinned copper
shield. PVC outer sheath, extensively resistant to oil
and cooling liquid, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

46

Technical data
Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

573 0005 002


573 0005 003
573 0005 004
573 0005 005
573 0005 007
573 0005 012
573 0005 014
573 0005 016
573 0005 018
573 0005 025
573 0005 030
573 0005 034
573 0005 036
573 0005 042
573 0005 050
573 0005 061

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
14 G 0,5
16 G 0,5
18 G 0,5
25 G 0,5
30 G 0,5
34 G 0,5
36 G 0,5
42 G 0,5
50 G 0,5
61 G 0,5

39
44
52
63
80
128
141
150
164
210
238
264
279
324
372
443

7,5
7,8
8,2
9,3
10,7
12,4
12,8
13,6
14,4
16,4
17,4
18,6
18,6
19,7
21,7
23,8

79
83
92
116
158
220
251
278
305
392
437
518
535
602
716
810

573 0007 002


573 0007 031
573 0007 003
573 0007 004
573 0007 005
573 0007 007
573 0007 012
573 0007 014
573 0007 016
573 0007 018
573 0007 025
573 0007 030
573 0007 034
573 0007 036
573 0007 042
573 0007 050
573 0007 061

2 X 0,75
3 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
14 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
30 G 0,75
34 G 0,75
36 G 0,75
42 G 0,75
50 G 0,75
61 G 0,75

39
52
52
66
82
107
168
187
203
221
275
356
387
429
474
539
641

8,1
8,4
8,4
9,4
10,3
12,1
13,6
13,9
15,0
15,9
18,6
19,9
21,0
21,0
22,4
23,7
26,7

87
95
95
127
143
201
283
311
342
394
515
644
686
720
795
899
1042

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

573 0010 002


573 0010 003
573 0010 004
573 0010 005
573 0010 007
573 0010 012
573 0010 016
573 0010 018
573 0010 025
573 0010 034
573 0010 041
573 0010 050
573 0010 065

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
65 G 1,0

59
73
86
104
129
196
242
288
372
521
618
698
868

9,9
10,2
10,9
11,7
13,5
15,5
17,1
17,9
21,0
23,8
26,1
27,9
32,3

116
144
168
190
245
365
424
505
667
848
1015
1217
1510

573 0015 002


573 0015 003
573 0015 004
573 0015 005
573 0015 007
573 0015 012
573 0015 016
573 0015 018
573 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5

74
96
116
133
175
262
333
377
507

10,3
10,7
11,4
12,3
14,5
16,3
19,3
20,3
23,2

130
168
206
245
345
458
528
635
985

573 0025 003


573 0025 004
573 0025 005
573 0025 007

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

124
154
185
253

12,8
13,7
15,2
17,6

254
318
387
498

573 0040 003


573 0040 004
573 0040 005
573 0040 007

3G4
4G4
5G4
7G4

178
221
270
370

15,5
16,6
17,9
21,1

374
446
547
718

573 0060 004


573 0060 005
573 0060 007

4G6
5G6
7G6

312
398
532

18,9
20,5
23,7

596
762
890

573 0100 004


573 0100 005

4 G 10
5 G 10

496
686

22,7
24,5

890
1016

573 0160 004


573 0160 005

4 G 16
5 G 16

759
1024

25,4
28,0

1374
1831

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

47

CC-Schleppflex PVC-C-573
High flexible single core cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-573 E172073 CUS STYLE 10107 600V 90C DESINA

Technical data
Rated voltage:
DIN VDE/IEC 600/1000 V
UL/CSA 600 V

Test voltage:
4000 V

Conductor stranding:
CC-Schleppflex PVC-C-573 UL/CSA and acc. to
DESINA-standard, single core shielded with PVC
outer sheath, is used as a control cable in
power supply chains. It can be used in damp and wet
areas. The overall copper shield ensures exact signal
transmission and protects the cable against
electromagnetic disturbances and influences. Along
service life is achieved by the special structure and
PVC mixture of CC-Schleppflex.

bare superfine copper strands,


acc. to UL 1581, Tab. 20.1
acc. to DIN VDE 0295, class 6

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, black or green/yellow core, tinned
copper shield. PVC-based outer sheath,
extensively resistant to oil and cooling liquid,
flame retardant and self-extinguishing
(acc.to.DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour DESINA-orange (RAL2003)

48

-40C to +90C
-5C to +90C

Bending radius:
fixed installation: 3 X cable diameter
flexible application: 7,5 X cable diameter

Approvals:
acc. to DINVDE 0250, 0281
UL: Style 10107
CSA:AWM I A/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

AWG

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

573 0801 00
573 0801 99

1 X 10
1 G 10

AWG 8
AWG 8

122
122

9,5
9,5

210
210

573 0601 00
573 0601 99

1 X 16
1 G 16

AWG 6
AWG 6

176
176

10,6
10,6

273
273

573 0401 00
573 0401 99

1 X 25
1 G 25

AWG 4
AWG 4

284
284

11,9
11,9

370
370

573 0201 00
573 0201 99

1 X 35
1 G 35

AWG 2
AWG 2

390
390

15,1
15,1

585
585

573 01001 00
573 01001 99

1 X 50
1 G 50

AWG 1/0
AWG 1/0

558
558

16,9
16,9

802
802

573 02001 00
573 02001 99

1 X 70
1 G 70

AWG 2/0
AWG 2/0

718
718

18,1
18,1

935
935

573 03001 00
573 03001 99

1 X 95
1 G 95

AWG 3/0
AWG 3/0

925
925

20,4
20,4

1280
1280

573 04001 00
573 04001 99

1 X 120
1 G 120

AWG 4/0
AWG 4/0

1152
1152

23,2
23,2

1500
1500

573 30001 00
573 30001 99

1 X 150
1 G 150

MCM 300
MCM 300

1490
1490

26,4
26,4

1950
1950

573 35001 00
573 35001 99

1 X 185
1 G 185

MCM 350
MCM 350

2049
2049

29,9
29,9

2600
2600

573 45001 00
573 45001 99

1 X 240
1 G 240

MCM 450
MCM 450

2470
2470

34,3
34,3

3380
3380

573 50001 00
573 50001 99

1 X 300
1 G 300

MCM 500
MCM 500

3030
3030

36,8
36,8

4110
4110

The metrical size is being followed


PUR version please refer to page 120

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

49

CC-Schleppflex PVC-C-573
High flexible control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-573 12G1,0 E172073 CUS STYLE 2587 AWM 600V 90C

CC-Schleppflex PVC-C-573 UL/CSA shielded


with PVC outer sheath, is used as a control cable
in power supply chains, sensor technology, computers and for control devices of instrument and
control engineering. It can be used in damp and
wet areas, not for outdoor usage. The overall copper shield ensures exact signal transmission and
protects the cable against
electromagnetic disturbances and influences. A
long service life is achieved by the special structure and PVC mixture of CC-Schleppflex.

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, cores are black with consecutive
white numbering. Cables with 3 cores or more
contain a green/yellow protective conductor in the
outer layer. Cores twisted in layers in short lay
lengths. PVC inner sheath, tinned copper shield.
PVC-based outer sheath, UV resistant,
extensively resistant to oil and cooling liquid,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).
Red and blue core colours upon request.

50

Technical data
Rated voltage:

DIN VDE/IEC: 300/500 V


UL/CSA: 600 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

fixed installation:
flexible application:

Temperature range:
-30C to +90C
-5C to +90C

Bending radius:
7,5 X cable diameter
Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 2587
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

No. of cores

No. of cores

+
crosssection

573 20 03
573 20 04
573 20 05
573 20 07
573 20 12
573 20 18
573 20 25

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20

31,7
44,0
52,9
65,3
109,1
160,7
227,5

8,5
9,1
9,7
10,7
13,1
15,0
18,0

100
121
142
200
280
403
533

573 19 02
573 19 03
573 19 04
573 19 05
573 19 07
573 19 12
573 19 16
573 19 18
573 19 25

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75

2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
12 X AWG 19
16 X AWG 19
18 X AWG 19
25 X AWG 19

39,1
46,5
58,0
67,1
93,5
157,0
178,0
214,0
310,0

8,4
8,9
9,5
10,1
11,9
13,9
15,7
16,5
20,1

125
140
157
180
260
330
400
490
600

573 18 02
573 18 03
573 18 04
573 18 05
573 18 07
573 18 12
573 18 16
573 18 18
573 18 25
573 18 34
573 18 41
573 18 50
573 16 02
573 16 03
573 16 04
573 16 05
573 16 07
573 16 12
573 16 16
573 16 18
573 16 25
573 16 34
573 16 42
573 16 50

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
16 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
50 X AWG 18
2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
16 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
42 X AWG 16
50 X AWG 16

50,0
60,0
68,4
80,3
116,4
190,1
226,0
290,0
375,0
454,8
540,0
690,0
55,0
73,4
90,4
109,6
149,2
245,0
300,0
360,0
478,9
650,0
766,1
930,0

8,6
9,3
10,0
10,7
12,4
15,4
16,6
17,4
20,3
23,2
25,0
27,0
9,2
9,2
10,2
11,2
13,3
15,8
18,6
19,4
22,5
25,1
29,3
31,0

136
150
175
205
285
380
500
565
740
975
1068
1220
138
158
201
227
349
489
678
740
981
1321
1377
1560

573 14 03
573 14 04
573 14 05
573 14 07
573 14 12

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5

3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
12 X AWG 14

111,5
136,2
167,8
230,0
379,9

10,8
11,3
12,5
14,5
19,6

214
334
354
503
746

3 X AWG 12
4 X AWG 12
5 X AWG 12
7 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6

155,0
212,4
265,0
370,0
296,0
481,6
714,5

14,2
15,2
16,8
19,4
16,9
21,1
25,5

296
404
498
717
541
881
1405

Part-No.

573 12 03
573 12 04
573 12 05
573 12 07
573 10 04
573 08 04
573 06 04

3 G 4,0
4 G 4,0
5 G 4,0
7 G 4,0
4 G 6,0
4 G 10,0
4 G 16,0

51

CC-Schleppflex PUR-575
High flexible data cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-575 25x0,25

CC-Schleppflex PUR-575 is used as a data- and


signal cable for power supply chains, sensor
technology, computers and for control devices of
instrument and control engineering. It can be used
in damp and wet areas. It is suitable in areas where
aggressive mineral oils occur and where strong
mechanical performances are required. The PUR
outer sheath is cut, notch and abrasion resistant.

Technical data
Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Construction
Superfine strands of bare copper wire.
PVC-based core insulation, core colours
acc. to DIN 47100. Cores are twisted in layers in very
short lay lengths. PUR outer sheath, flame retardant
and self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and
IEC 60332-1), non-adhesive, resistant to hydrolysis
and microbes. Colour grey (RAL 7001).

Temperature range:

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter


Approvals:
acc. to DIN VDE 0245, 0281, 0812

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

52

fixed installation:
flexible application:

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

575 0001 003


575 0001 004
575 0001 005
575 0001 007
575 0001 010
575 0001 014
575 0001 018
575 0001 025

3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

4,1
5,6
7,0
9,8
14,0
19,6
25,2
35,0

4,4
4,6
5,0
6,0
6,8
7,3
7,9
9,3

25
30
34
48
60
74
87
118

575 0002 002


575 0002 003
575 0002 004
575 0002 005
575 0002 007
575 0002 010
575 0002 014
575 0002 018
575 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

5,0
7,5
10,0
12,5
17,5
25,0
35,0
45,0
62,5

4,6
4,8
5,5
6,0
7,1
8,0
8,3
9,1
11,1

29
34
37
46
63
82
100
127
168

575 0003 002


575 0003 003
575 0003 004
575 0003 005
575 0003 007
575 0003 010
575 0003 014
575 0003 018
575 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

6,8
10,2
13,6
17,0
23,8
34,0
47,6
61,2
85,0

5,2
5,5
6,6
6,8
7,9
9,2
9,9
10,6
12,8

35
39
57
58
82
108
146
173
235

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

53

CC-Schleppflex PUR-575
High flexible control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-575 34G1,0

Technical data
Rated voltage:

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:

Superfine strands of bare copper wire.


PVC-based core insulation, black cores with
consecutive white numbering. Control cables with
3 cores or more have a green/yellow protective
conductor in the outer layer. Cores are twisted in
layers in very short lay lengths. PUR outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1), non-adhesive, resistant to hydrolysis and
microbes. Colour grey (RAL 7001).

54

300/500 V

CC-Schleppflex PUR-575 is used as a control cable for


power supply chains, sensor technology,
computers and for control devices of instrument and
control engineering. It can be used in damp and wet
areas. CC-Schleppflex PUR-575 is suitable in areas
where aggressive mineral oils occur and where strong
mechanical performances are required. The PUR outer
sheath is cut, notch and abrasion resistant.

Test voltage:
3000 V

Conductor stranding:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

575 0005 003


575 0005 004
575 0005 005
575 0005 007
575 0005 012
575 0005 018
575 0005 025
575 0005 034

3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5

14,4
19,2
24,0
34,0
58,0
86,4
120,0
163,2

6,6
7,0
7,4
8,6
10,1
12,2
15,8
17,1

46
58
72
85
135
194
264
343

575 0007 003


575 0007 004
575 0007 005
575 0007 007
575 0007 012
575 0007 016
575 0007 018
575 0007 025
575 0007 034

3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75

21,6
29,0
36,0
50,0
86,0
116,0
130,0
180,0
245,0

6,8
7,4
8,0
9,5
11,3
12,6
13,5
16,7
19,4

55
68
82
104
186
222
243
341
445

575 0010 003


575 0010 004
575 0010 005
575 0010 007
575 0010 012
575 0010 016
575 0010 018
575 0010 025
575 0010 034
575 0010 041
575 0010 050
575 0010 065

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
65 G 1,0

29,0
38,4
48,0
67,0
115,0
153,0
173,0
240,0
326,0
394,0
480,0
624,0

7,2
7,8
8,5
10,2
12,2
13,8
14,7
18,0
19,8
21,5
23,1
26,5

68
95
129
208
227
272
310
412
555
667
802
1038

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

575 0015 003


575 0015 004
575 0015 005
575 0015 007
575 0015 012
575 0015 016
575 0015 018
575 0015 025
575 0015 034
575 0015 042
575 0015 050
575 0015 061

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5

43,0
58,0
72,0
101,0
173,0
230,0
259,0
360,0
490,0
605,0
720,0
878,0

8,0
8,7
9,7
11,8
13,7
15,9
16,5
20,2
21,9
23,8
26,0
30,2

87
108
132
169
282
368
464
554
752
905
1104
1325

575 0025 003


575 0025 004
575 0025 005
575 0025 007
575 0025 012
575 0025 014
575 0025 018
575 0025 025

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
14 G 2,5
18 G 2,5
25 G 2,5

72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

9,6
10,7
12,0
14,4
16,9
18,1
21,5
26,6

128
155
197
258
454
521
656
915

575 0040 003


575 0040 004
575 0040 005
575 0040 007

3G4
4G4
5G4
7G4

115,2
154,0
192,0
269,0

11,4
12,5
13,9
15,8

208
264
312
516

575 0060 00
575 0060 99
575 0060 004
575 0060 005

1X6
1G6
4G6
5G6

58,0
58,0
230,0
288,0

7,0
7,0
14,9
16,4

85
85
382
465

575 0100 99
575 0100 004
575 0100 005

1 G 10
4 G 10
5 G 10

96,0
384,0
480,0

8,4
18,5
20,4

140
465
621

575 0160 00
575 0160 99
575 0160 004
575 0160 005

1 X 16
1 G 16
4 G 16
5 G 16

154,0
154,0
614,0
768,0

10,0
10,0
21,8
24,0

188
188
862
1045

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

55

CC-Schleppflex PUR-575
High flexible control cable
Conform to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt - 575 25 G 2,5 E 172073 c AWM STYLE 20234 600V 80C

Technical data
Rated voltage:

CC-Schleppflex PUR-575 UL/CSA is used as a


control cable for power supply chains, sensor
technology, computers and for control devices of
instrument and control engineering. It can be used
in damp and wet areas.
CC-Schleppflex PUR-575 is suitable in areas where
aggressive mineral oils occur and where strong
mechanical performances are required. The PUR
outer sheath is cut, notch and abrasion resistant.

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:

Superfine strands of bare copper wire.


PVC-based core insulation, black cores with
consecutive white numbering. Control cables with
3 cores or more have a green/yellow protective
conductor in the outer layer. Cores are twisted in
layers in very short lay lengths. PUR outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001). Black outer sheath and
red or blue core colours upon request.

56

DINVDE/IEC: 300/500 V
UL/CSA: 600 V

Test voltage:
4000 V

Conductor stranding:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

-30C to +80C
-5C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10012/20234
CSA: AWM IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

575 20 03
575 20 04
575 20 05
575 20 07
575 20 12
575 20 18
575 20 25
575 20 34
575 19 02
575 19 03
575 19 04
575 19 05
575 19 07
575 19 12
575 19 16
575 19 18
575 19 25
575 19 34

3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75

3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20
34 X AWG 20
2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
12 X AWG 19
16 X AWG 19
18 X AWG 19
25 X AWG 19
34 X AWG 19

14,4
19,2
24,0
34,0
58,0
86,4
120,0
163,2
14,4
21,6
29,0
36,0
50,0
86,0
110,0
130,0
180,0
245,0

7,0
7,5
8,1
9,7
11,2
13,0
15,2
16,8
7,0
7,3
7,9
8,5
9,8
11,8
13,0
13,7
16,1
17,8

46
58
72
85
135
194
265
343
49
60
72
89
132
186
240
270
368
526

575 18 03
575 18 04
575 18 05
575 18 07
575 18 12
575 18 16
575 18 18
575 18 25
575 18 34
575 18 41
575 16 02
575 16 03
575 16 04
575 16 05
575 16 07
575 16 12
575 16 16
575 16 18
575 16 25
575 16 34
575 16 50
575 16 61
575 14 03
575 14 04
575 14 05
575 14 07
575 14 12
575 12 04
575 12 05
575 12 07
575 10 04
575 10 07
575 08 04
575 06 04

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
50 G 1,5
61 G 1,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
4G4
5G4
7G4
4G6
7G6
4 G 10
4 G 16

3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
16 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
16 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
50 X AWG 16
61 X AWG 16
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
12 X AWG 14
4 X AWG 12
5 X AWG 12
7 X AWG 12
4 X AWG 10
7 X AWG 10
4 X AWG 8
4 X AWG 6

29,0
38,4
48,0
67,0
115,0
153,0
173,0
240,0
326,0
394,0
29,0
43,0
58,0
72,0
101,0
173,0
230,0
259,0
360,0
490,0
720,0
878,0
72,0
96,0
120,0
168,0
288,0
154,0
192,0
269,0
230,0
403,0
384,0
615,0

7,8
8,4
9,1
10,5
12,6
14,0
14,7
17,2
19,0
21,5
7,9
8,3
9,0
9,7
11,3
13,7
15,2
16,2
19,2
21,4
26,9
27,4
9,2
9,9
10,8
14,5
15,5
13,4
14,8
18,3
15,1
20,0
18,1
21,1

63
83
104
152
218
272
320
412
623
670
67
87
108
132
169
282
320
464
554
752
1104
1325
128
155
197
258
453
264
312
516
382
751
601
851

57

CC-Schleppflex PUR-C-576
High flexible data cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-576 14x0,34

CC-Schleppflex PUR-C-576 shielded is used as a


data- and signal cable for power supply chains, sensor
technology, computers and for control devices of
instrument and control engineering. It can be used in
damp and wet areas. The overall
copper shield ensures exact signal transmission and
protects the cable against electromagnetic
disturbances and influences. CC-Schleppflex
PUR-C-576 is suitable in areas where aggressive
mineral oils occur and where strong mechanical
performances are required. The PUR outer sheath is
cut, notch and abrasion resistant.

Technical data
Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, core colours acc. to DIN 47100, cores
twisted in layers in very short lay lengths,
tinned copper shield. PUR-based outer sheath, flame
retardant, self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

58

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

576 0001 002


576 0001 003
576 0001 004
576 0001 005
576 0001 007
576 0001 010
576 0001 012
576 0001 014
576 0001 018
576 0001 025

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

11,2
14,1
15,5
18,3
27,8
39,3
42,1
45,3
54,1
68,4

4,3
4,5
4,8
5,1
6,4
7,3
7,5
7,6
8,4
9,9

30
34
38
44
55
84
91
105
113
152

576 0002 002


576 0002 003
576 0002 004
576 0002 005
576 0002 007
576 0002 010
576 0002 012
576 0002 014
576 0002 018
576 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

14,9
18,8
21,3
31,0
39,6
53,9
57,1
64,2
78,4
101,0

4,7
4,9
5,7
6,3
7,1
8,3
8,6
8,7
9,6
11,3

35
40
46
53
74
96
108
130
158
210

576 0003 002


576 0003 003
576 0003 004
576 0003 005
576 0003 007
576 0003 010
576 0003 012
576 0003 014
576 0003 018
576 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

18,1
28,7
35,7
39,1
52,7
67,4
76,6
85,8
99,7
155,0

5,7
6,2
6,6
7,1
8,3
9,8
10,1
10,2
11,3
13,6

45
61
77
83
109
147
166
186
216
314

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

59

CC-Schleppflex PUR-C-576
High flexible control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-576 12G1,0

CC-Schleppflex PUR-C-576 shielded is used as a


control cable for power supply chains,
sensor technology, computers and for control devices
of instrument and control engineering. It can be used
in damp and wet areas. The overall
copper shield ensures exact data transmission and
protects the cable against electromagnetic
disturbances and influences. CC-Schleppflex
PUR-C-576 is suitable in areas where aggressive
mineral oils occur and where strong mechanical
performances are required. The PUR outer sheath is
cut, notch and abrasion resistant.

Construction
Superfine strands of bare copper wire, PVC-based
core insulation, cores are black with consecutive
white numbering, control cables with 3 cores or more
contain a green/yellow protective conductor in the
outer layer, cores twisted in layers in very short lay
lengths. Special core wrapping, PVC inner sheath,
tinned copper shield. PUR-based outer sheath, flame
retardant, self-extinguishing (acc. to DIN
VDE 0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

60

Technical data
Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

576 0005 003


576 0005 004
576 0005 005
576 0005 007
576 0005 012
576 0005 018
576 0005 025

3 G 0,5
4G 0,5
5G 0,5
7G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

48,0
58,0
75,0
78,0
111,0
169,0
210,0

7,8
7,9
8,4
9,8
11,3
13,4
16,1

100
115
134
162
228
340
436

576 0007 003


576 0007 004
576 0007 005
576 0007 007
576 0007 012
576 0007 014
576 0007 018
576 0007 025
576 0007 034

3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
14 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75

55,0
79,0
87,0
129,0
144,0
167,0
228,0
310,0
378,0

7,8
8,4
9,0
10,7
12,4
14,0
14,9
18,0
22,0

118
135
162
194
286
341
434
568
702

576 0010 003


576 0010 004
576 0010 005
576 0010 007
576 0010 012
576 0010 016
576 0010 018
576 0010 025
576 0010 034
576 0010 041
576 0010 050
576 0010 065

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0
65 G 1,0

56,0
78,0
82,0
89,0
161,0
236,0
283,0
360,0
440,0
586,0
685,0
878,0

8,2
8,9
9,8
11,4
13,4
15,2
16,1
19,5
23,5
25,4
27,0
31,4

136
167
195
275
404
472
597
818
1100
1250
1416
1835

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

576 0015 003


576 0015 004
576 0015 005
576 0015 007
576 0015 012
576 0015 016
576 0015 018
576 0015 025
576 0015 034
576 0015 042
576 0015 050

3 G 1,5
4G 1,5
5G 1,5
7G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5

84,0
90,0
107,0
158,0
259,0
321,0
394,0
583,0
625,0
872,0
919,0

9,0
9,9
10,9
12,7
15,1
16,8
17,8
21,9
27,5
29,8
32,3

170
290
315
354
521
650
732
1000
1115
1534
1807

576 0025 003


576 0025 004
576 0025 005
576 0025 007
576 0025 012

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5

136,0
145,0
198,0
236,0
420,0

10,8
11,8
13,2
15,8
18,2

269
315
395
517
728

576 0040 003


576 0040 004
576 0040 005

3G4
4G4
5G4

188,0
214,0
285,0

12,4
13,7
15,3

315
395
527

576 0060 004


576 0060 005

4G6
5G6

286,0
435,0

16,1
17,1

505
736

576 0100 004


576 0100 005

4 G 10
5 G 10

470,0
698,0

20,2
22,2

1043
1100

576 0160 004


576 0160 005

4 G 16
5 G 16

795,0
1045,0

23,2
26,1

1340
1685

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

61

CC-Schleppflex PUR-C-576
High flexible control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt - 576 25 G 0,5 E 172073 cr AWM STYLE 20234 600V 80C

CC-Schleppflex PUR-C-576 shielded UL/CSA is


used as a control cable for power supply chains,
sensor technology, computers and for control devices
of instrument and control engineering. Further it can
be used for handling equipment and is suitable
for damp and wet areas. The overall copper shield
ensures exact data transmission and protects the cable
against electromagnetic disturbances and influences.
CC-Schleppflex PUR-C-576 is suitable in areas
where aggressive mineral oils occur and strong
mechanical performances are required.
The PUR outer sheath is cut, notch and abrasion
resistant.

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:

Superfine strands of bare copper wire, PVC-based


core insulation, cores are black with consecutive
white numbering, control cables with 3 cores or more
contain a green/yellow protective conductor in the
outer layer, cores twisted in layers in very short lay
lengths, PVC inner sheath, tinned copper shield.
PUR-based outer sheath, flame retardant,
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001). Black outer sheath and red
or blue core colours upon request.

62

Technical data
Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

-30C to +70C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10012/20234
CSA: AWM IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

576 20 03
576 20 04
576 20 05
576 20 07
576 20 12
576 20 18
576 20 25
576 20 34
576 19 02
576 19 03
576 19 04
576 19 05
576 19 07
576 19 12
576 19 16
576 19 18
576 19 25
576 19 34
576 18 02
576 18 03
576 18 04
576 18 05
576 18 07
576 18 12
576 18 16
576 18 18
576 18 25
576 18 34
576 18 41
576 16 02
576 16 03
576 16 04
576 16 05
576 16 07
576 16 12
576 16 16
576 16 18
576 16 25
576 16 34
576 16 50

3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
50 G 1,5

3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20
34 X AWG 20
2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
12 X AWG 19
16 X AWG 19
18 X AWG 19
25 X AWG 19
34 X AWG 19
2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
16 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
16 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
50 X AWG 16

31,7
44,0
52,9
65,3
109,1
160,7
227,5
298,5
39,1
46,5
58,0
67,1
93,5
157,0
178,0
214,0
310,0
399,5
50,0
60,0
68,4
80,3
116,4
190,0
226,0
290,0
375,0
454,8
540,0
55,0
73,4
90,4
109,6
149,2
245,0
300,0
360,0
478,9
650,0
930,0

9,1
9,8
10,4
11,6
14,0
16,2
19,3
21,5
9,3
9,2
10,2
10,9
12,7
14,8
16,0
18,2
21,0
23,8
9,2
9,4
10,4
11,2
13,2
15,6
17,2
18,9
22,0
24,5
26,7
9,3
10,6
11,4
12,3
14,1
17,2
18,8
19,6
23,6
27,0
32,0

128
145
161
195
266
409
575
712
85
113
140
166
225
300
330
460
590
800
136
130
160
185
250
350
450
525
680
865
1040
138
170
290
315
354
521
620
732
1000
1115
1807

576 14 03
576 14 04
576 14 05
576 14 07
576 14 12
576 14 18
576 12 04
576 12 07
576 10 04
576 10 07
576 08 04
576 06 04

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
18 G 2,5
4 G 4,0
7 G 4,0
4 G 6,0
7 G 6,0
4 G 10,0
4 G 16,0

3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
12 X AWG 14
18 X AWG 14
4 X AWG 12
7 X AWG 12
4 X AWG 10
7 X AWG 10
4 X AWG 8
4 X AWG 6

111,5
136,2
167,8
230,0
379,9
609,0
212,4
370,0
296,0
461,0
481,6
714,5

12,6
13,5
15,0
16,9
21,2
23,6
16,0
19,8
17,7
23,6
18,0
20,0

269
315
395
517
728
1134
395
769
505
950
1043
1173

63

CC-Schleppflex PUR-572
Superflexible halogen-free data cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-572 180,25

CC-Schleppflex PUR-572 superflexible is used as a


data and signal cable in mobile power supply chains,
sensor technology, computer systems, control devices
for measurement and control technology as well as in
industrial robots and handling equipment, for in- and
outdoor use. It can be used in areas where aggressive
and mineral oils occur and where the cable is
exposed to high mechanical stress and small bending
radius. The PUR outer sheath is cut, notch and
abrasion resistant.

Technical data
Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Construction
Superfine strands of bare copper wire,
polyester (TPE) core insulation, core colours acc. to
DIN 47100, fleece. Cores twisted in layers in very
short lay lengths. PUR-based outer sheath, flame retardant and self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

-50C to +80C
-40C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812

Cross-section (mm2)):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

64

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

572 0001 002


572 0001 003
572 0001 004
572 0001 005
572 0001 007
572 0001 010
572 0001 012
572 0001 014
572 0001 018
572 0001 025

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2,7
4,0
5,4
6,7
9,4
13,4
16,1
18,8
24,2
33,6

4,2
4,2
4,5
4,9
5,7
5,9
6,0
6,4
6,8
8,2

21
25
28
35
47
62
67
71
84
124

572 0002 002


572 0002 003
572 0002 004
572 0002 005
572 0002 007
572 0002 010
572 0002 012
572 0002 014
572 0002 018
572 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

5,0
7,5
10,0
12,5
17,5
25,0
30,1
35,0
45,0
62,5

4,1
4,3
4,8
5,0
5,9
7,3
7,9
8,3
8,7
9,8

25
29
38
47
58
82
93
104
127
166

572 0003 002


572 0003 003
572 0003 004
572 0003 005
572 0003 007
572 0003 010
572 0003 012
572 0003 014
572 0003 018
572 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

6,5
9,8
13,1
16,3
22,8
32,6
39,2
45,7
58,8
85,0

4,2
5,1
5,7
6,3
6,3
7,0
7,0
7,3
8,4
9,8

32
38
53
64
78
105
126
147
178
247

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

65

CC-Schleppflex PUR-574
Low capacitance, superflexible halogen-free data cable
Conforms to EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-574 25x0,25 E244335 CUS AWM STYLE 20549 300V 80C

CC-Schleppflex PUR-574 UL/CSA


superflexible is used as a data and signal cable with
low capacity for power supply chains,
sensor technology, computers and for control devices
of instrument and control engineering. Further it can
be used for handling equipment and is suitable
in- and outdoors. It can be used in areas where
aggressive mineral oils occur and where strong
mechanical performances are required. The PUR
outer sheath is cut, notch and abrasion resistant.

Construction
Superfine strands of bare copper wire, polyolefin core
insulation, core colours acc. to DIN 47100. Cores
twisted in layers in very short lay lengths. PUR outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and
microbes. Colour grey (RAL 7001).

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operation capacity at 800 Hz:

core/core max. 60 nF/km

Insulation resistance:

min. 200 MOhm X km

Temperature range:

fixed installation:
flexible application:

-50C to +80C
-40C to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 20549, 20233 CMX
CSA: AWM C22.2 N 210.2-M90 FT1

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt) VDE / UL, CSA:

300

300

300

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

66

Technical data

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

574 26 02
574 26 03
574 26 04
574 26 05
574 26 07
574 26 10
574 26 12
574 26 14
574 26 18
574 26 25

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2 X AWG 26
3 X AWG 26
4 X AWG 26
5 X AWG 26
7 X AWG 26
10 X AWG 26
12 X AWG 26
14 X AWG 26
18 X AWG 26
25 X AWG 26

2,8
4,2
5,6
7,0
9,9
14,1
16,9
19,7
25,3
35,2

3,8
4,0
4,2
4,4
5,0
5,8
6,0
6,2
6,6
7,5

14
15
17
20
27
33
38
42
52
73

574 24 02
574 24 03
574 24 04
574 24 05
574 24 07
574 24 10
574 24 12
574 24 14
574 24 18
574 24 25

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

2 X AWG 24
3 X AWG 24
4 X AWG 24
5 X AWG 24
7 X AWG 24
10 X AWG 24
12 X AWG 24
14 X AWG 24
18 X AWG 24
25 X AWG 24

5,0
7,5
10,0
12,5
17,6
27,6
30,1
35,1
45,1
62,7

4,2
4,4
4,6
5,0
5,6
6,6
6,8
7,1
7,9
8,9

18
20
24
28
38
53
55
63
79
110

574 22 02
574 22 03
574 22 04
574 22 05
574 22 07
574 22 10
574 22 12
574 22 14
574 22 18
574 22 25

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

2 X AWG 22
3 X AWG 22
4 X AWG 22
5 X AWG 22
7 X AWG 22
10 X AWG 22
12 X AWG 22
14 X AWG 22
18 X AWG 22
25 X AWG 22

6,6
9,9
13,2
16,5
23,1
33,0
39,6
46,2
59,2
82,5

4,4
4,6
4,9
5,2
6,0
7,1
7,2
7,5
8,4
9,7

21
23
28
33
46
59
68
77
97
142

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

67

CC-Schleppflex PUR-572
Superflexible halogen-free control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-572 12G0,5

CC-Schleppflex PUR-572 superflexible is used as


a control cable in power supply chains,
sensor technology, computer systems and control
devices for measurement and control technology as
well as in industrial robots and handling equipment,
for in- and outdoor use. It can be used in areas where
aggressive and mineral oils occur and where the
cable is exposed to high mechanical stress and small
bending radius. The PUR outer sheath is cut, notch
and abrasion resistant.

Construction
Superfine strands of bare copper wire,
polyester (TPE) core insulation, cores are black with
consecutive white numbering, 3 cores or more
contain a green/yellow protective conductor in the
outer layer. Cores twisted in layers in very short lay
lengths, bandage over each layer. PUR-based outer
sheath, flame retardant and self-extinguishing
(acc. to DIN. VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

68

Technical data
Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-50C to +80C
-40C to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

572 0005 002


572 0005 003
572 0005 004
572 1005 004
572 0005 005
572 0005 007
572 0005 012
572 0005 014
572 0005 018
572 0005 020
572 0005 025
572 0005 027
572 0005 030
572 0005 034
572 0005 036
572 0005 041
572 0005 050

2 X 0,5
3 G 0,5
4 G 0,5
4 X 0,5
5 G 0,5
7 G 0,5
12 G 0,5
14 G 0,5
18 G 0,5
20 G 0,5
25 G 0,5
27 G 0,5
30 G 0,5
34 G 0,5
36 G 0,5
41 G 0,5
50 G 0,5

9,6
14,4
19,2
19,2
24,0
34,0
58,0
67,0
86,4
96,0
120,0
130,0
144,0
163,2
173,0
197,0
240,0

5,1
5,4
5,8
6,1
6,2
7,4
8,8
9,7
10,4
11,2
12,6
13,3
13,6
14,1
14,1
15,0
16,8

34
41
48
48
57
82
120
139
176
191
214
239
257
284
301
352
433

572 0007 002


572 0007 003
572 0007 004
572 0007 005
572 0007 007
572 0007 012
572 0007 014
572 0007 018
572 0007 020
572 0007 025
572 0007 030
572 0007 034
572 0007 036
572 0007 041
572 0007 050

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
14 G 0,75
18 G 0,75
20 G 0,75
25 G 0,75
30 G 0,75
34 G 0,75
36 G 0,75
41 G 0,75
50 G 0,75

14,4
21,6
29,0
36,0
50,0
86,0
101,0
130,0
144,0
180,0
216,0
245,0
259,0
296,0
360,0

5,5
5,9
6,3
6,9
8,1
10,1
10,6
11,5
12,2
14,0
15,0
15,4
15,6
17,1
18,6

43
51
66
75
105
166
192
227
252
318
364
420
448
519
645

572 0010 002


572 0010 003
572 0010 004
572 0010 005
572 0010 007
572 0010 012
572 0010 014
572 0010 018
572 0010 020
572 0010 025
572 0010 027
572 0010 030
572 0010 034
572 0010 036

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
14 G 1,0
18 G 1,0
20 G 1,0
25 G 1,0
27 G 1,0
30 G 1,0
34 G 1,0
36 G 1,0

19,2
29,0
38,4
48,0
67,0
115,0
134,0
173,0
192,0
240,0
259,0
288,0
326,0
346,0

6,1
6,5
7,0
7,5
8,8
11,0
11,5
12,7
13,6
15,2
15,8
16,3
16,8
17,3

50
64
78
100
129
208
237
286
309
384
423
449
501
528

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

572 0010 041


572 0010 050
572 0010 065

41 G 1,0
50 G 1,0
65 G 1,0

393,0
480,0
624,0

18,4
20,6
23,0

599
731
956

572 0015 002


572 0015 003
572 0015 004
572 0015 005
572 0015 007
572 0015 012
572 0015 014
572 0015 018
572 0015 020
572 0015 025
572 0015 027
572 0015 030
572 0015 034
572 0015 036
572 0015 042
572 0015 050
572 0015 061
572 0015 065

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
14 G 1,5
18 G 1,5
20 G 1,5
25 G 1,5
27 G 1,5
30 G 1,5
34 G 1,5
36 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0
202,0
259,0
288,0
360,0
389,0
432,0
490,0
518,0
605,0
720,0
878,0
936,0

6,5
7,1
7,7
8,3
10,2
12,3
13,1
14,3
15,3
17,4
17,6
18,1
19,2
19,4
21,2
27,2
30,0
31,7

67
83
106
134
173
288
330
404
466
574
613
665
737
772
881
1009
1207
1279

572 0025 003


572 0025 004
572 0025 005
572 0025 007
572 0025 012
572 0025 014
572 0025 018
572 0025 025

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
14 G 2,5
18 G 2,5
25 G 2,5

72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

8,2
8,9
10,2
11,7
14,3
15,5
17,2
21,1

157
189
246
328
529
615
779
1064

572 0040 003


572 0040 004
572 0040 005
572 0040 007

3G4
4G4
5G4
7G4

115,2
154,0
192,0
269,0

10,2
11,1
12,1
14,4

224
276
357
474

572 0060 003


572 0060 004
572 0060 005
572 0060 007

3G6
4G6
5G6
7G6

173,0
230,0
288,0
403,0

11,5
12,5
13,9
16,6

328
416
524
751

572 0100 003


572 0100 004
572 0100 005

3 G 10
4 G 10
5 G 10

288,0
384,0
480,0

14,5
16,1
17,9

508
644
805

572 0160 004


572 0160 005

4 G 16
5 G 16

614,0
768,0

18,9
21,3

1075
1376

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

69

CC-Schleppflex PUR-572
Superflexible halogen-free control cable
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-572 25G0,5 E172073 CUS AWM STYLE 20234 600V 80C

Technical data
CC-Schleppflex PUR-572 UL/CSA superflexible is
used as a control cable in power supply chains,
sensor technology, computer systems and control
devices for measurement and control technology as
well as in industrial robots and handling
equipment, for in- and outdoor use. It can be used in
areas where aggressive and mineral oils occur and
where the cable is exposed to high
mechanical stress and small bending radius.
The PUR outer sheath is cut, notch and abrasion
resistant.

Rated voltage:

DIN VDE/IEC:
UL/CSA:

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Construction
Superfine strands of bare copper wire,
polyester (TPE) core insulation, cores are black with
consecutive white numbering, 3 cores or more contain a green/yellow protective conductor in the outer
layer. Cores twisted in layers in very short lay
lengths, bandage over each layer. PUR-based outer
sheath, flame retardant and self-extinguishing
(acc. to DIN. VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1),
non- adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

70

300/500 V
600 V

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/B, FT1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

572 20 02
572 20 03
572 20 04
572 20 05
572 20 07
572 20 12
572 20 14
572 20 18
572 20 20
572 20 25
572 20 27
572 20 30
572 20 34
572 20 36
572 20 41
572 20 50

2 X 0,5 /20
3 G 0,5 /20
4 G 0,5 /20
5 G 0,5 /20
7 G 0,5 /20
12 G 0,5 /20
14 G 0,5 /20
18 G 0,5 /20
20 G 0,5 /20
25 G 0,5 /20
27 G 0,5 /20
30 G 0,5 /20
34 G 0,5 /20
36 G 0,5 /20
41 G 0,5 /20
50 G 0,5 /20

9,6
14,4
19,2
24,0
34,0
58,0
67,0
86,4
96,0
120,0
130,0
144,0
163,2
173,0
197,0
240,0

5,8
6,1
6,5
6,9
7,8
9,3
9,7
10,6
11,2
12,6
13,3
13,8
14,1
14,3
15,2
16,8

34
41
48
57
82
120
139
176
191
214
239
257
284
301
352
433

572 19 02
572 19 03
572 19 04
572 19 05
572 19 07
572 19 12
572 19 14
572 19 18
572 19 20
572 19 25
572 19 30
572 19 34
572 19 36
572 19 41
572 19 50

2 X 0,75 /19
3 G 0,75 /19
4 G 0,75 /19
5 G 0,75 /19
7 G 0,75 /19
12 G 0,75 /19
14 G 0,75 /19
18 G 0,75 /19
20 G 0,75 /19
25 G 0,75 /19
30 G 0,75 /19
34 G 0,75 /19
36 G 0,75 /19
41 G 0,75 /19
50 G 0,75 /19

14,4
21,6
29,0
36,0
50,0
86,0
101,0
130,0
144,0
180,0
216,0
245,0
259,0
296,0
360,0

6,2
6,5
6,9
7,6
8,5
10,1
10,6
11,7
12,4
14,0
15,1
15,5
15,7
17,1
18,6

43
51
66
75
105
166
192
227
252
318
364
420
448
519
645

572 18 02
572 18 03
572 18 04
572 18 05
572 18 07
572 18 12
572 18 14
572 18 18
572 18 20
572 18 25
572 18 27
572 18 30
572 18 34
572 18 36
572 18 41

2 X 1,0 /18
3 G 1,0 /18
4 G 1,0 /18
5 G 1,0 /18
7 G 1,0 /18
12 G 1,0 /18
14 G 1,0 /18
18 G 1,0 /18
20 G 1,0 /18
25 G 1,0 /18
27 G 1,0 /18
30 G 1,0 /18
34 G 1,0 /18
36 G 1,0 /18
41 G 1,0 /18

Part-No.

No. of cores
+
crosssection/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

572 18 50
572 18 65

50 G 1,0 /18
65 G 1,0 /18

480,0
624,0

20,4
23,0

731
956

572 16 02
572 16 03
572 16 04
572 16 05
572 16 07
572 16 12
572 16 14
572 16 18
572 16 20
572 16 25
572 16 27
572 16 30
572 16 34
572 16 36
572 16 42
572 16 50
572 16 61
572 16 65

2 X 1,5 /16
3 G 1,5 /16
4 G 1,5 /16
5 G 1,5 /16
7 G 1,5 /16
12 G 1,5 /16
14 G 1,5 /16
18 G 1,5 /16
20 G 1,5 /16
25 G 1,5 /16
27 G 1,5 /16
30 G 1,5 /16
34 G 1,5 /16
36 G 1,5 /16
42 G 1,5 /16
50 G 1,5 /16
61 G 1,5 /16
65 G 1,5 /16

29,0
43,0
58,0
72,0
101,0
173,0
202,0
259,0
288,0
360,0
389,0
432,0
490,0
518,0
605,0
720,0
878,0
936,0

7,2
7,6
8,1
8,8
10,1
12,3
13,1
14,4
15,3
17,3
17,6
18,1
19,4
19,4
21,2
27,2
30,0
31,7

67
83
106
134
173
288
330
404
466
574
613
665
737
772
881
1009
1207
1279

572 14 02
572 14 03
572 14 04
572 14 05
572 14 07
572 14 12
572 14 14
572 14 18
572 14 25

2 X 2,5 /14
3 G 2,5 /14
4 G 2,5 /14
5 G 2,5 /14
7 G 2,5 /14
12 G 2,5 /14
14 G 2,5 /14
18 G 2,5 /14
25 G 2,5 /14

48,0
72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

8,2
8,6
9,3
10,2
11,8
14,5
15,5
17,2
21,1

104
157
189
246
328
529
615
779
1064

572 12 03
3 G 4 /12
115,2
19,2
572 12 04
4 G 4 /12
154,0
6,6
50
29,0
572 12 05
5 G 4 /12
192,0
6,9
64
38,4
572 12 07
7 G 4 /12
269,0
7,4
78
48,0
8,0
100
67,0
572 10 03
3 G 6 /10
173,0
9,1
129
115,0
572 10 04
4 G 6 /10
230,0
10,9
208
134,0
572 10 05
5 G 6 /10
288,0
11,5
237
173,0
572 10 07
7 G 6 /10
403,0
12,7
286
192,0
13,6
309
240,0
572 08 03
3 G 10 /8
288,0
15,2
384
259,0
572 08 04
4 G 10 /8
384,0
16,1
423
288,0
572 08 05
5 G 10 /8
480,0
16,3
449
326,0
17,1
501
346,0
572 06 04
4 G 16 /6
614,0
18,1
528
393,0
572 06 05
5 G 16 /6
768,0
18,7
599
Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

10,7
11,8
12,9
15,2

224
276
357
474

12,1
13,2
14,7
17,3

328
416
524
751

14,9
16,5
18,3

508
644
805

19,1
21,4

1075
1376

ConCab kabel connects the world

71

CC-Schleppflex PUR-574
Low capacitance, superflexible halogen-free control cable
Conforms to EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-572 25G0,5 E172073 CUS AWM STYLE 20234 600V 80C

CC-Schleppflex PUR-574 UL/CSA superflexible is


used as a control cable with low capacity in power
supply chains, sensor technology,
computer systems and control devices for
measurement and control technology as well as in
industrial robots and handling equipment,
for in- and outdoor use. It is designed especially for
long travel distances up to 25m. It can be used in
areas where aggressive and mineral oils occur and
where the cable is exposed to high
mechanical stress and small bending radius.
The PUR outer sheath is cut, notch and abrasion
resistant.

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

Test voltage:
3000 V

Conductor stranding:

superfine copper wires


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Construction
Superfine strands of bare copper wire,
polypropylen (PP) core insulation, cores are
black with consecutive white numbering, 3 cores or
more contain a green/yellow protective conductor in
the outer layer. Cores twisted in layers in very short
lay lengths. PUR-based outer sheath, flame retardant
and self-extinguishing (acc. to DIN. VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non- adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

72

300/500 V
600 V

flexible application:
fixed installation:

Temperature range:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/B, FT1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

Part-No.

No. of cores
+
crosssection/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

574 18 50
574 18 65

50 G 1,0 /18
65 G 1,0 /18

480,0
624,0

20,4
23,0

731
956

574 16 02
574 16 03
574 16 04
574 16 05
574 16 07
574 16 12
574 16 14
574 16 18
574 16 20
574 16 25
574 16 27
574 16 30
574 16 34
574 16 36
574 16 42
574 16 50
574 16 61
574 16 65

2 X 1,5 /16
3 G 1,5 /16
4 G 1,5 /16
5 G 1,5 /16
7 G 1,5 /16
12 G 1,5 /16
14 G 1,5 /16
18 G 1,5 /16
20 G 1,5 /16
25 G 1,5 /16
27 G 1,5 /16
30 G 1,5 /16
34 G 1,5 /16
36 G 1,5 /16
42 G 1,5 /16
50 G 1,5 /16
61 G 1,5 /16
65 G 1,5 /16

29,0
43,0
58,0
72,0
101,0
173,0
202,0
259,0
288,0
360,0
389,0
432,0
490,0
518,0
605,0
720,0
878,0
936,0

7,2
7,6
8,1
8,8
10,1
12,3
13,1
14,4
15,3
17,4
17,6
18,1
19,4
19,4
21,2
27,2
30,0
31,7

67
83
106
134
173
288
330
404
466
574
613
665
737
772
881
1009
1207
1279

574 14 02
574 14 02
574 14 02
574 14 02
574 14 02
574 14 02
574 14 02
574 14 02
574 14 25

2 X 2,5 /14
3 G 2,5 /14
4 G 2,5 /14
5 G 2,5 /14
7 G 2,5 /14
12 G 2,5 /14
14 G 2,5 /14
18 G 2,5 /14
25 G 2,5 /14

48,0
72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

8,2
8,6
9,3
10,2
11,8
14,5
15,5
17,2
21,1

104
157
189
246
328
529
615
779
1064

574 12 03
3 G 4 /12
115,2
574 12 04
19,2
4 G 4 /12
154,0
6,6
50
574 12 05
29,0
5 G 4 /12
192,0
7,0
64
574 12 07
38,4
7 G 4 /12
269,0
7,4
78
48,0
8,2
100
574 10 03
67,0
3 G 6 /10
173,0
9,1
129
574 10 04
115,0
4 G 6 /10
230,0
10,9
208
574 10 05
134,0
5 G 6 /10
288,0
11,5
237
574 10 07
173,0
7 G 6 /10
403,0
12,7
286
192,0
13,6
309
574 08 03
240,0
3 G 10 /8
288,0
15,2
384
574 08 04
259,0
4 G 10 /8
384,0
16,1
423
574 08 05
288,0
5 G 10 /8
480,0
16,3
449
326,0
17,1
501
574 06 04
346,0
4 G 16 /6
614,0
18,1
528
574 06 05
393,0
5 G 16 /6
768,0
19,3
599
Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

10,7
11,8
12,9
15,2

224
276
357
474

12,1
13,2
14,7
17,3

328
416
524
751

14,9
16,5
18,3

508
644
805

19,1
21,4

1075
1376

574 20 02
574 20 03
574 20 04
574 20 05
574 20 07
574 20 12
574 20 14
574 20 18
574 20 20
574 20 25
574 20 27
574 20 30
574 20 34
574 20 36
574 20 41
574 20 50

2 X 0,5 /20
3 G 0,5 /20
4 G 0,5 /20
5 G 0,5 /20
7 G 0,5 /20
12 G 0,5 /20
14 G 0,5 /20
18 G 0,5 /20
20 G 0,5 /20
25 G 0,5 /20
27 G 0,5 /20
30 G 0,5 /20
34 G 0,5 /20
36 G 0,5 /20
41 G 0,5 /20
50 G 0,5 /20

9,6
14,4
19,2
24,0
34,0
58,0
67,0
86,4
96,0
120,0
130,0
144,0
163,2
173,0
197,0
240,0

5,8
6,1
6,5
6,9
7,8
9,3
9,7
10,6
11,2
12,6
13,3
13,8
14,1
14,3
15,2
16,8

34
41
48
57
82
120
139
176
191
214
239
257
284
301
352
433

574 19 02
574 19 03
574 19 04
574 19 05
574 19 07
574 19 12
574 19 14
574 19 18
574 19 20
574 19 25
574 19 30
574 19 34
574 19 36
574 19 41
574 19 50

2 X 0,75 /19
3 G 0,75 /19
4 G 0,75 /19
5 G 0,75 /19
7 G 0,75 /19
12 G 0,75 /19
14 G 0,75 /19
18 G 0,75 /19
20 G 0,75 /19
25 G 0,75 /19
30 G 0,75 /19
34 G 0,75 /19
36 G 0,75 /19
41 G 0,75 /19
50 G 0,75 /19

14,4
21,6
29,0
36,0
50,0
86,0
101,0
130,0
144,0
180,0
216,0
245,0
259,0
296,0
360,0

6,2
6,5
6,9
7,6
8,5
10,2
10,6
11,7
12,4
14,0
15,1
15,5
15,7
17,1
18,6

43
51
66
75
105
166
192
227
252
318
364
420
448
519
645

574 18 02
574 18 03
574 18 04
574 18 05
574 18 07
574 18 12
574 18 14
574 18 18
574 18 20
574 18 25
574 18 27
574 18 30
574 18 34
574 18 36
574 18 41

2 X 1,0 /18
3 G 1,0 /18
4 G 1,0 /18
5 G 1,0 /18
7 G 1,0 /18
12 G 1,0 /18
14 G 1,0 /18
18 G 1,0 /18
20 G 1,0 /18
25 G 1,0 /18
27 G 1,0 /18
30 G 1,0 /18
34 G 1,0 /18
36 G 1,0 /18
41 G 1,0 /18

ConCab kabel connects the world

73

CC-Schleppflex PUR-C-569
Superflexible halogen-free data cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-569 140,14

CC-Schleppflex PUR-C-569 superflexible shielded is


used as a data and signal cable in power supply
chains, sensor technology, computer systems and
control devices for measurement and control
technology as well as in industrial robots and
handling equipment, for in- and outdoor use. It can be
used in areas where aggressive and mineral oils occur
and where the cable is exposed to high mechanical
stress and small bending radius.
The overall copper shield ensures exact data
transmission and protects the cable against
electromagnetic disturbances and influences.
The PUR outer sheath is cut, notch and abrasion
resistant.

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:

Superfine strands of bare copper wire,


polyester (TPE) core insulation, core colours acc.
to DIN 47100, cores twisted in layers in very short
lay lengths, bandage over each layer, tinned copper
shield. PUR-based outer sheath is flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

Conductor stranding:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt):

250

250

250

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

74

Technical data

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

569 0001 002


569 0001 003
569 0001 004
569 0001 005
569 0001 007
569 0001 010
569 0001 012
569 0001 014
569 0001 018
569 0001 025

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

11,3
14,5
15,7
18,5
25,9
39,6
42,4
46,0
52,5
64,7

4,7
4,6
5,2
5,4
6,2
6,7
6,7
7,3
7,9
9,2

30
34
38
44
58
78
92
101
111
148

569 0002 002


569 0002 003
569 0002 004
569 0002 005
569 0002 007
569 0002 010
569 0002 012
569 0002 014
569 0002 018
569 0002 025

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

16,8
19,2
21,5
30,5
37,7
53,4
59,6
63,8
75,6
97,4

4,6
5,1
5,1
5,8
6,6
8,2
8,2
8,7
9,3
11,1

35
40
46
61
77
105
118
137
157
195

569 0003 002


569 0003 003
569 0003 004
569 0003 005
569 0003 007
569 0003 010
569 0003 012
569 0003 014
569 0003 018
569 0003 024
569 0003 025

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
24 X 0,34
25 X 0,34

19,9
27,2
34,4
38,6
51,2
65,8
74,9
86,4
96,7
148,4
151,6

4,8
5,0
5,5
5,6
6,5
7,6
7,6
9,8
10,6
13,0
13,0

43
57
78
84
108
151
162
181
222
318
321

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

75

CC-Schleppflex PUR-C-592
Low capacitance, superflexible halogen-free data cable, shielded
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-592 10x0,25 E244335 CUS AWM STYLE 20549 300V 80C

CC-Schleppflex PUR-C-592 UL/CSA superflexible


shielded with low capacitance is used as a data and
signal cable in power supply chains, sensor
technology, computer systems and control devices for
measurement and control technology as well as in
industrial robots and handling equipment, for in- and
outdoor use. It can be used in areas where aggressive
and mineral oils occur and where the cable is
exposed to high mechanical stress and small
bending radius. The overall copper shield ensures
exact data transmission and protects the cable against
electromagnetic disturbances and influences.
The PUR outer sheath is cut, notch and abrasion
resistant.

Construction
Superfine strands of bare copper wire,
polyolefin core insulation, core colours acc.
to DIN 47100, cores twisted in layers in very short
lay lengths, tinned copper shield. PUR-based outer
sheath is flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operation capacity at 800 Hz:

core/core approx. 60 nF/km


core/shield approx. 160 nF/km

Insulation resistance:

min. 200 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 20549, 20233 CMX
CSA: AWM C 22.2 N 210.2-M90 FT1

Cross-section (mm2):

0,14

0,25

0,34

Rated voltage (Volt) VDE / UL, CSA:

300

300

300

1500

1500

1500

 138

 79

 57

Test voltage (Volt):


Conductor resistance (Ohm/km):

76

Technical data

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

592 26 02
592 26 03
592 26 04
592 26 05
592 26 07
592 26 10
592 26 12
592 26 14
592 26 18
592 26 25

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
18 X 0,14
25 X 0,14

2 X AWG 26
3 X AWG 26
4 X AWG 26
5 X AWG 26
7 X AWG 26
10 X AWG 26
12 X AWG 26
14 X AWG 26
18 X AWG 26
25 X AWG 26

8,5
10,5
12,5
14,5
19,0
25,0
28,0
31,5
38,5
52,0

4,2
4,4
4,6
4,8
5,4
6,3
6,3
6,7
7,2
8,1

18
18
21
24
31
37
41
46
57
77

592 24 02
592 24 03
592 24 04
592 24 05
592 24 07
592 24 10
592 24 12
592 24 14
592 24 18
592 24 25

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
18 X 0,25
25 X 0,25

2 X AWG 24
3 X AWG 24
4 X AWG 24
5 X AWG 24
7 X AWG 24
10 X AWG 24
12 X AWG 24
14 X AWG 24
18 X AWG 24
25 X AWG 24

11,7
14,7
18,0
21,4
28,1
37,9
43,4
49,2
61,0
86,4

4,6
4,8
5,0
5,4
6,0
7,0
7,2
7,4
8,3
9,6

26
28
33
38
50
63
70
78
96
143

592 22 02
592 22 03
592 22 04
592 22 05
592 22 07
592 22 10
592 22 12
592 22 14
592 22 18
592 22 25

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
18 X 0,34
25 X 0,34

2 X AWG 22
3 X AWG 22
4 X AWG 22
5 X AWG 22
7 X AWG 22
10 X AWG 22
12 X AWG 22
14 X AWG 22
18 X AWG 22
25 X AWG 22

13,8
17,6
21,7
26,0
34,4
46,8
53,9
61,3
80,8
108,7

4,8
5,0
5,3
5,6
6,5
7,8
7,9
8,1
8,9
10,2

29
32
37
44
58
74
83
93
120
171

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

77

CC-Schleppflex PUR-C-569
Superflexible halogen-free control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-569 12G1,0

CC-Schleppflex PUR-C-569 superflexible shielded is


used as a control cable in power supply chains, sensor
technology, computer systems, control devices for
measurement and control technology as well as in
industrial robots and handling equipment, for in- and
outdoor use. It can be used in areas where aggressive
and mineral oils occur and where the cable is exposed
to high mechanical stress and small bending radius.
The overall copper shield ensures exact data
transmission and protects the cable against
electromagnetic disturbances and influences. The
PUR outer sheath is cut, notch and abrasion resistant.

Construction
Superfine strands of bare copper wire,
polyester (TPE) core insulation, cores are black with
consecutive white numbering, cables with 3 cores or
more contain a green/yellow protective conductor in
the outer layer, cores twisted in layers in very short
lay lengths, bandage over each layer, PUR inner
sheath, tinned copper shield. PUR-based outer sheath
is flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

78

Technical data
Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

ConCab kabel connects the world

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

569 0005 002


569 0005 003
569 0005 004
569 0005 005
569 0005 007
569 0005 012
569 0005 014
569 0005 018
569 0005 020
569 0005 025
569 0005 030
569 0005 036
569 0005 050

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
14 G 0,5
18 G 0,5
20 G 0,5
25 G 0,5
30 G 0,5
36 G 0,5
50 G 0,5

34,0
45,0
52,0
61,0
74,0
99,0
109,0
132,0
155,0
187,0
224,0
255,0
345,0

7,2
7,5
7,9
8,2
9,7
10,7
11,6
12,8
13,8
15,4
15,8
16,8
20,1

65
73
91
112
125
187
212
262
287
350
413
488
725

569 0007 002


569 0007 003
569 0007 004
569 0007 005
569 0007 007
569 0007 012
569 0007 014
569 0007 018
569 0007 020
569 0007 025
569 0007 030
569 0007 032
569 0007 036

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
14 G 0,75
18 G 0,75
20 G 0,75
25 G 0,75
30 G 0,75
32 G 0,75
36 G 0,75

41,0
49,1
61,6
70,0
89,7
154,0
167,0
205,0
220,0
277,0
315,0
323,0
370,0

7,6
7,8
8,4
8,7
10,4
12,2
13,0
14,0
14,8
16,6
18,0
18,0
18,6

81
98
115
131
171
243
276
324
375
449
514
610
625

569 0010 002


569 0010 003
569 0010 004
569 0010 005
569 0010 007
569 0010 012
569 0010 014
569 0010 018
569 0010 020
569 0010 025
569 0010 030
569 0010 034
569 0010 036
569 0010 041
569 0010 050
569 0010 065

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
14 G 1,0
18 G 1,0
20 G 1,0
25 G 1,0
30 G 1,0
34 G 1,0
36 G 1,0
41 G 1,0
50 G 1,0
65 G 1,0

49,0
59,0
71,8
84,4
114,0
188,0
216,0
271,0
302,0
375,0
445,0
505,0
529,0
599,0
725,0
935,0

7,9
8,2
8,8
9,7
10,6
13,1
13,9
15,1
16,2
18,0
19,0
19,6
20,0
21,3
23,4
25,4

98
125
149
173
225
295
343
439
487
610
730
826
874
996
1212
1572

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

569 0015 002


569 0015 003
569 0015 004
569 0015 005
569 0015 007
569 0015 012
569 0015 014
569 0015 018
569 0015 020
569 0015 025
569 0015 030
569 0015 034
569 0015 042
569 0015 050

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
14 G 1,5
18 G 1,5
20 G 1,5
25 G 1,5
30 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5

56,0
87,0
104,0
122,0
169,0
270,0
315,0
388,0
432,0
528,0
603,0
783,0
834,0
995,0

8,6
9,3
10,0
10,6
12,1
14,8
15,7
16,9
18,2
20,2
21,0
22,3
24,2
30,4

138
164
191
233
285
425
477
595
647
792
924
1028
1236
1444

569 0025 003


569 0025 004
569 0025 005
569 0025 007
569 0025 012
569 0025 014
569 0025 018
569 0025 025

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
14 G 2,5
18 G 2,5
25 G 2,5

134,0
164,0
195,0
281,0
445,0
551,0
687,0
898,0

11,0
11,5
12,3
14,2
17,3
18,3
20,2
24,1

230
303
398
510
722
806
974
1268

569 0040 004


569 0040 005
569 0040 007

4G4
5G4
7G4

232,0
291,0
378,0

13,7
15,1
18,5

453
528
613

569 0060 004


569 0060 005
569 0060 007

4G6
5G6
7G6

337,0
438,0
532,0

15,3
16,7
19,0

602
735
942

569 0100 004


569 0100 005

4 G 10
5 G 10

512,0
626,0

18,9
21,1

948
1077

569 0160 004


569 0160 005

4 G 16
5 G 16

790,0
1045,0

21,9
24,4

1405
1790

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

79

CC-Schleppflex PUR-C-569
Superflexible halogen-free control cable, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-569 12G0,5 E172073 CUS AWM STYLE 20234 600V 80C

CC-Schleppflex PUR-C-569 UL/CSA


superflexible shielded is used as a control cable in
power supply chains, sensor
technology, computer systems, control
devices for measurement and control
technology as well as in industrial robots and
handling equipment, for in- and outdoor use. It can be
used in areas where aggressive and mineral oils occur
and where the cable is exposed to high mechanical
stress and small bending radius. The overall copper
shield ensures exact data transmission and protects
the cable against electromagnetic disturbances and
influences. The PUR outer sheath is cut, notch and
abrasion resistant.

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction
Superfine strands of bare copper wire,
polyester (TPE) core insulation, cores are black with
consecutive white numbering, cables with 3 cores or
more contain a green/yellow protective conductor in
the outer layer, cores twisted in layers in very short
lay lengths, bandage over each layer, PUR inner
sheath, tinned copper shield. PUR-based outer sheath
is flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

80

300/500 V
600 V

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/B, FT1

ConCab kabel connects the world

Part-No.

No. of cores
+
cross-section/
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

569 20 02
569 20 03
569 20 04
569 20 05
569 20 07
569 20 12
569 20 14
569 20 18
569 20 20
569 20 25
569 20 30
569 20 36
569 20 50

2 X 0,5 /20
3 G 0,5 /20
4 G 0,5 /20
5 G 0,5 /20
7 G 0,5 /20
12 G 0,5 /20
14 G 0,5 /20
18 G 0,5 /20
20 G 0,5 /20
25 G 0,5 /20
30 G 0,5 /20
36 G 0,5 /20
50 G 0,5 /20

34,0
45,0
52,0
61,0
74,0
99,0
109,0
132,0
155,0
187,0
224,0
255,0
345,0

7,8
8,1
8,5
8,9
9,9
11,4
12,0
12,9
13,8
15,4
15,8
16,8
20,1

65
73
91
112
125
187
212
262
287
350
413
488
725

569 19 02
569 19 03
569 19 04
569 19 05
569 19 07
569 19 12
569 19 14
569 19 18
569 19 20
569 19 25
569 19 30
569 19 32
569 19 36

2 X 0,75 /19
3 G 0,75 /19
4 G 0,75 /19
5 G 0,75 /19
7 G 0,75 /19
12 G 0,75 /19
14 G 0,75 /19
18 G 0,75 /19
20 G 0,75 /19
25 G 0,75 /19
30 G 0,75 /19
32 G 0,75 /19
36 G 0,75 /19

41,0
49,1
61,6
70,0
89,7
154,0
167,0
205,0
220,0
277,0
315,0
323,0
370,0

8,2
8,5
8,9
9,6
10,6
12,4
13,0
14,2
15,0
16,6
17,6
18,0
18,6

81
98
115
131
171
243
276
324
375
449
514
610
625

569 18 02
569 18 03
569 18 04
569 18 05
569 18 07
569 18 12
569 18 14
569 18 18
569 18 20
569 18 25
569 18 30
569 18 34
569 18 36
569 18 41
569 18 50
569 18 65

2 X 1,0 /18
3 G 1,0 /18
4 G 1,0 /18
5 G 1,0 /18
7 G 1,0 /18
12 G 1,0 /18
14 G 1,0 /18
18 G 1,0 /18
20 G 1,0 /18
25 G 1,0 /18
30 G 1,0 /18
34 G 1,0 /18
36 G 1,0 /18
41 G 1,0 /18
50 G 1,0 /18
65 G 1,0 /18

49,0
59,0
71,8
84,4
114,0
188,0
216,0
271,0
302,0
375,0
445,0
505,0
529,0
599,0
725,0
935,0

8,6
8,9
9,5
10,1
11,3
13,5
13,9
15,3
16,2
18,0
19,0
20,5
20,5
22,5
24,3
26,9

98
125
149
173
225
295
343
439
487
610
730
826
874
996
1212
1572

Part-No.

No. of cores
+
cross-section/
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

569 16 02
569 16 03
569 16 04
569 16 05
569 16 07
569 16 12
569 16 14
569 16 18
569 16 20
569 16 25
569 16 30
569 16 34
569 16 42
569 16 50

2 X 1,5 /16
3 G 1,5 /16
4 G 1,5 /16
5 G 1,5 /16
7 G 1,5 /16
12 G 1,5 /16
14 G 1,5 /16
18 G 1,5 /16
20 G 1,5 /16
25 G 1,5 /16
30 G 1,5 /16
34 G 1,5 /16
42 G 1,5 /16
50 G 1,5 /16

56,0
87,0
104,0
122,0
169,0
270,0
315,0
388,0
432,0
528,0
603,0
783,0
834,0
995,0

9,3
9,6
10,3
10,7
12,4
14,9
15,7
17,0
18,2
20,6
21,2
22,2
25,0
30,4

138
164
191
233
285
425
477
595
647
792
924
1028
1236
1444

569 14 03
569 14 04
569 14 05
569 14 07
569 14 12
569 14 14
569 14 18
569 14 25

3 G 2,5 /14
4 G 2,5 /14
5 G 2,5 /14
7 G 2,5 /14
12 G 2,5 /14
14 G 2,5 /14
18 G 2,5 /14
25 G 2,5 /14

134,0
164,0
195,0
281,0
445,0
551,0
687,0
898,0

11,0
11,5
12,5
14,3
17,3
18,3
20,2
24,5

230
303
398
510
722
806
974
1268

569 12 04
569 12 05
569 12 07

4 G 4 /12
5 G 4 /12
7 G 4 /12

232,0
291,0
378,0

14,6
15,9
18,5

453
528
613

569 10 04
569 10 05
569 10 07

4 G 6 /10
5 G 6 /10
7 G 6 /10

337,0
438,0
532,0

16,2
17,5
21,0

602
735
942

569 08 04
569 08 05

4 G 10 /8
5 G 10 /8

512,0
626,0

19,9
22,4

948
1077

569 06 04
569 06 05

4 G 16 /6
5 G 16 /6

790,0
1045,0

23,2
25,3

1405
1790

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

81

CC-Schleppflex PUR-C-592
Low capacitance, superflexible halogen-free data cable, shielded
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-569 12G0,5 E172073 CUS AWM STYLE 20234 600V 80C

CC-Schleppflex PUR-C-592 UL/CSA


superflexible shielded is used as a control cable with
low capacity in power supply chains for long travel
distances, sensor technology, computer systems,
control devices for measurement and control
technology as well as in industrial robots and
handling equipment, for in- and outdoor use. It can be
used in areas where aggressive and mineral oils occur
and where the cable is exposed to high mechanical
stress and small bending radius. The overall copper
shield ensures exact data transmission and protects
the cable against electromagnetic disturbances and
influences. The PUR outer sheath is cut, notch and
abrasion resistant.

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction
Superfine strands of bare copper wire,
polypropylen (PP) core insulation, cores are black
with consecutive white numbering, cables with 3
cores or more contain a green/yellow protective
conductor in the outer layer, cores twisted in layers in
very short lay lengths, PUR inner sheath, tinned
copper shield. PUR-based outer sheath is
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

82

300/500 V
600 V

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/B, FT1

ConCab kabel connects the world

Part-No.

No. of cores
+
cross-section/
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

592 20 02
592 20 03
592 20 04
592 20 05
592 20 07
592 20 12
592 20 14
592 20 18
592 20 20
592 20 25
592 20 30
592 20 36
592 20 50

2 X 0,5 /20
3 G 0,5 /20
4 G 0,5 /20
5 G 0,5 /20
7 G 0,5 /20
12 G 0,5 /20
14 G 0,5 /20
18 G 0,5 /20
20 G 0,5 /20
25 G 0,5 /20
30 G 0,5 /20
36 G 0,5 /20
50 G 0,5 /20

26,0
33,0
40,0
47,0
66,0
100,0
114,0
141,0
160,0
195,0
241,0
281,0
377,0

7,8
8,1
8,5
8,9
9,9
11,4
12,0
12,9
13,8
15,4
15,8
16,8
20,1

65
73
91
112
125
187
212
262
287
350
413
488
725

592 19 02
592 19 03
592 19 04
592 19 05
592 19 07
592 19 12
592 19 14
592 19 18
592 19 20
592 19 25
592 19 30
592 19 32
592 19 36

2 X 0,75 /19
3 G 0,75 /19
4 G 0,75 /19
5 G 0,75 /19
7 G 0,75 /19
12 G 0,75 /19
14 G 0,75 /19
18 G 0,75 /19
20 G 0,75 /19
25 G 0,75 /19
30 G 0,75 /19
32 G 0,75 /19
36 G 0,75 /19

31,0
39,0
48,0
57,0
80,0
125,0
141,0
182,0
200,0
259,0
299,0
317,0
350,0

8,2
8,5
8,9
9,6
10,6
12,4
13,0
14,3
15,0
16,6
18,0
18,0
18,6

81
98
115
131
171
243
276
324
375
449
514
610
625

592 18 02
592 18 03
592 18 04
592 18 05
592 18 07
592 18 12
592 18 14
592 18 18
592 18 20
592 18 25
592 18 30
592 18 34
592 18 36
592 18 41
592 18 50
592 18 65

2 X 1,0 /18
3 G 1,0 /18
4 G 1,0 /18
5 G 1,0 /18
7 G 1,0 /18
12 G 1,0 /18
14 G 1,0 /18
18 G 1,0 /18
20 G 1,0 /18
25 G 1,0 /18
30 G 1,0 /18
34 G 1,0 /18
36 G 1,0 /18
41 G 1,0 /18
50 G 1,0 /18
65 G 1,0 /18

37,0
48,0
59,0
76,0
100,0
163,0
185,0
231,0
268,0
311,0
363,0
430,0
450,0
509,0
607,0
771,0

8,6
8,9
9,5
10,1
11,2
13,4
13,9
15,3
16,2
18,0
19,0
20,5
20,5
22,5
24,1
26,9

98
125
149
173
225
295
343
439
487
610
730
826
874
996
1212
1572

Part-No.

No. of cores
+
cross-section/
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

592 16 02
592 16 03
592 16 04
592 16 05
592 16 07
592 16 12
592 16 14
592 16 18
592 16 20
592 16 25
592 16 30
592 16 34
592 16 42
592 16 50

2 X 1,5 /16
3 G 1,5 /16
4 G 1,5 /16
5 G 1,5 /16
7 G 1,5 /16
12 G 1,5 /16
14 G 1,5 /16
18 G 1,5 /16
20 G 1,5 /16
25 G 1,5 /16
30 G 1,5 /16
34 G 1,5 /16
42 G 1,5 /16
50 G 1,5 /16

53,0
65,0
87,0
104,0
139,0
229,0
262,0
327,0
361,0
466,0
544,0
613,0
834,0
871,0

9,3
9,7
10,3
10,9
12,4
14,9
15,7
17,0
18,2
20,7
21,2
23,2
25,0
30,4

138
164
191
233
285
425
477
595
647
792
924
1028
1236
1444

592 14 03
592 14 04
592 14 05
592 14 07
592 14 12
592 14 14
592 14 18
592 14 25

3 G 2,5 /14
4 G 2,5 /14
5 G 2,5 /14
7 G 2,5 /14
12 G 2,5 /14
14 G 2,5 /14
18 G 2,5 /14
25 G 2,5 /14

104,0
131,0
160,0
222,0
375,0
411,0
540,0
734,0

11,0
11,5
12,5
14,4
17,3
18,3
20,5
24,5

230
303
398
510
722
806
974
1268

592 12 04
592 12 05
592 12 07

4 G 4 /12
5 G 4 /12
7 G 4 /12

204,0
249,0
337,0

14,6
15,9
18,5

453
528
613

592 10 04
592 10 05
592 10 07

4 G 6 /10
5 G 6 /10
7 G 6 /10

290,0
355,0
506,0

16,2
17,5
21,0

602
735
942

592 08 04
592 08 05

4 G 10 /8
5 G 10 /8

484,0
592,0

19,9
22,4

948
1077

592 06 04
592 06 05

4 G 16 /6
5 G 16 /6

739,0
909,0

23,2
25,3

1405
1790

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

83

CC-Control Cable-TPE-571
Halogen-free robust control cable 600V
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 571 25G2,5 E172073 CUS STYLE 20234 600V 80C

Technical data

The flexible CC-Control cable


TPE-571 UL/CSA has been developed for use in
machineries where high mechanical stress occurs and
where flexibility and extensive chemical resistance
are required. The special TPE-based outer sheath
allows the cable to be used in- and outdoors as well
as in sewage- and seawater. It is also suitable for the
food- and beverage industry. Additionally, the outer
sheath is extensively resistant to acids and lye,
to industrial solvents, as well as mineral and hydro
synthetic oils.

Construction
Fine strands of bare copper wire, TPE-based core
insulation, cores are black with
consecutive white numbering, cables with
3 cores or more contain a green/yellow
protective conductor in the outer layer, cores are
twisted in layers in very short lay lengths, special
TPE-based outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1,
IEC 60332-1 and UL VW-1).
Colour black (RAL 9005).

84

Rated voltage:
DIN VDE/IEC:
300/500 V
UL/CSA:
600 V
Test voltage:
4000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C to +80C
-50C to +80C

flexible application:
installation:

Bending radius:
20 X cable diameter
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250, 0282
UL: Style 20234
CSA: AWM I/II A/B FT1
flame resistance: VW-1

Part-No.

No. of
cores
+
crosssection

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

571 18 02
571 18 03
571 18 04
571 18 05
571 18 07
571 18 09
571 18 12
571 18 18
571 18 25
571 18 34
571 18 41
571 18 50

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
9 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
50 X AWG 18

19,2
29,0
38,4
48,0
67,0
86,4
115,0
173,0
240,0
326,0
393,0
480,0

5,8
6,1
6,6
7,3
8,1
11,0
10,7
12,9
15,0
17,5
19,2
21,0

42
53
66
80
107
172
213
262
357
484
582
703

571 16 02
571 16 03
571 16 04
571 16 05
571 16 07
571 16 09
571 16 12
571 16 18
571 16 25
571 16 41

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
41 G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16
41 X AWG 16

29,0
43,0
58,0
72,0
101,0
130,0
173,0
259,0
360,0
591,0

6,4
6,8
7,4
8,3
9,0
12,0
12,2
14,6
17,2
21,2

56
72
91
112
149
211
251
369
510
868

571 14 02
571 14 03
571 14 04
571 14 07
571 14 09
571 14 12
571 14 18
571 14 25

2 X 2,5
3 G 2,5
4 G 2,5
7 G 2,5
9 G 2,5
12 G 2,5
18 G 2,5
25 G 2,5

2 X AWG 14
3 X AWG 14
4 X AWG 14
7 X AWG 14
9 X AWG 14
12 X AWG 14
18 X AWG 14
25 X AWG 14

48,0
72,0
96,0
168,0
216,0
288,0
432,0
600,0

7,6
8,3
9,0
11,2
13,9
15,1
17,2
21,1

86
115
144
241
290
405
779
1064

571 12 03
571 12 04
571 12 05

3G4
4G4
5G4

3 X AWG 12
4 X AWG 12
5 X AWG 12

115,0
157,0
192,0

10,1
11,1
12,4

180
228
280

571 10 03
571 10 04
571 10 05

3G6
4G6
5G6

3 X AWG 10
4 X AWG 10
5 X AWG 10

173,0
230,0
288,0

12,1
13,3
14,8

328
332
407

571 08 04
571 08 05

4 G 10
5 G 10

4 X AWG 8
5 X AWG 8

384,0
480,0

16,5
18,4

541
664

571 06 04
571 06 05

4 G 16
5 G 16

4 X AWG 6
5 X AWG 6

614,4
768,0

18,8
21,4

806
1376

571 04 04

4 G 25

4 X AWG 4

960,0

23,5

1218

ConCab kabel connects the world

85

CC-Control Cable-TPE-C-568
Halogen-free robust control cable 600V
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 568 25G1,5 E172073 CUS STYLE 20234 600V 80C

Technical data
Rated voltage:
DIN VDE/IEC:
300/500 V
UL/CSA:
600 V
The flexible CC-Control cable TPE-C-568 shielded
UL/CSA has been developed for use in machineries
where high mechanical stress occurs and where
flexibility and extensive chemical resistance are
required. The TPE-based outer sheath allows the
cable to be used in- and outdoors as well as in
sewage- and seawater. It is also suitable for the
food- and beverage industry.The outer sheath is
extensively resistant to acids and lye, to industrial
solvents, as well as mineral and hydrosynthetic oils.

Construction
Fine strands of bare copper wire, TPE-based core
insulation, cores are black with consecutive white
numbering, cables with 3 cores or more contain a
green/yellow protective conductor in the outer layer,
cores twisted in layers in very short lay lengths,
tinned copper shield. Special TPE-based outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1, IEC 60332-1 and UL VW-1).
Colour black (RAL 9005).

86

Test voltage:
4000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C to +80C
-50C to +80C

flexible application:
installation:

Bending radius:
20 X cable diameter
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250, 0282
UL: Style 20234
CSA: AWM I/II A/B FT1
flame resistance: VW-1

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

568 18 03
568 18 04
568 18 05
568 18 07
568 18 12
568 18 18
568 18 25

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18

62
74
88
112
185
268
354

6,8
7,5
8,2
9,0
11,6
14,0
16,0

110
130
156
192
285
385
656

568 16 03
568 16 04
568 16 05
568 16 07
568 16 12
568 16 18
568 16 25

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16

82
100
119
154
268
373
530

7,5
8,3
9,0
10,1
13,2
15,9
18,1

126
165
193
245
365
553
734

568 14 02
568 14 03
568 14 04
568 14 07

2 X 2,5
3 G 2,5
4 G 2,5
7 G 2,5

2 X AWG 14
3 X AWG 14
4 X AWG 14
7 X AWG 14

94
118
147
253

8,9
9,0
9,9
11,9

168
188
236
340

568 12 03
568 12 04

3G4
4G4

3 X AWG 12
4 X AWG 12

155
190

11,5
11,5

270
305

568 10 03
568 10 04
568 10 05

3G6
4G6
5G6

3 X AWG 10
4 X AWG 10
5 X AWG 10

240
290
420

14,4
14,4
17,1

398
440
702

568 08 04

4 G 10

4 X AWG 8

473

17,4

710

568 06 04

4 G 16

4 X AWG 6

765

20,1

1150

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

87

CC-Schleppflex PUR-C-(TP)-510
High flexible data cable paired, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-(TP)-510 6 x 2 x 0,75 E172073 CUS AWM STYLE 20233 300V 80C

CC-Schleppflex PUR-C-(TP)-510 UL/CSA shielded


is used for transmitting analogue and digital signals in
power supply chains, sensor technology and to
connect transmitters and sensors for measurement
and control technology. It can be used where
aggressive and mineral oils occur and where the cable
is exposed to high mechanical stress. The overall
copper shield ensures exact data transmission and
protects the cable against electromagnetic
disturbances and influences. Coordinated twisted
lengths of the pairs ensure low coupling rates. The
PUR outer sheath is cut and notch resistant
and non-abrasive.

Construction
Superfine strands of bare copper wires, PVC core
insulation, core colours acc. to DIN47100. Cores
twisted in pairs, special core wrapping, tinned copper
shield. PUR outer sheath, flame retardant
and self-extinguishing (acc. to DIN VDE 0482,
Teil 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operating capacity at 800 Hz:

core/core approx. 120 nF/km

Insulation resistance:

min. 20 MOhm X km

Temperature range:

flexible application:
fixed installation:

-5C to +80C
-30C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0812


UL: Style 1061/20233
CSA: AWM I A/B, II A/B FT 1

Cross-section (mm2):

0,25

0,50

0,75

1,0

Rated voltage (Volt):

300

300

300

300

2000

2000

2000

2000

 158

78

 52

 40

Test voltage (Volt):


Loop resistance (Ohm/km):

88

Technical data

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

510 24 01
510 24 02
510 24 03
510 24 04
510 24 05
510 24 06
510 24 08
510 24 10
510 24 14

1 X 2 X 0,25
2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
14 X 2 X 0,25

1 X 2 X AWG 24
2 X 2 X AWG 24
3 X 2 X AWG 24
4 X 2 X AWG 24
5 X 2 X AWG 24
6 X 2 X AWG 24
8 X 2 X AWG 24
10 X 2 X AWG 24
14 X 2 X AWG 24

14,0
32,0
38,4
43,2
51,5
71,8
74,4
90,0
111,2

5,0
7,1
7,4
8,4
9,0
9,8
11,5
12,8
13,4

27
60
72
89
103
131
155
186
219

510 20 01
510 20 02
510 20 03
510 20 04
510 20 05
510 20 06
510 20 08
510 20 10
510 20 14

1 X 2 X 0,5
2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
5 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
14 X 2 X 0,5

1 X 2 X AWG 20
2 X 2 X AWG 20
3 X 2 X AWG 20
4 X 2 X AWG 20
5 X 2 X AWG 20
6 X 2 X AWG 20
8 X 2 X AWG 20
10 X 2 X AWG 20
14 X 2 X AWG 20

22,0
50,0
71,8
74,4
84,5
99,6
144,3
176,0
215,4

6,4
9,3
10,0
11,1
11,9
12,8
15,7
17,6
18,3

47
99
130
148
168
194
284
343
401

510 19 01
510 19 02
510 19 03
510 19 04
510 19 05
510 19 06
510 19 08
510 19 10
510 19 14

1 X 2 X 0,75
2 X 2 X 0,75
3 X 2 X 0,75
4 X 2 X 0,75
5 X 2 X 0,75
6 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
14 X 2 X 0,75

1 X 2 X AWG 19
2 X 2 X AWG 19
3 X 2 X AWG 19
4 X 2 X AWG 19
5 X 2 X AWG 19
6 X 2 X AWG 19
8 X 2 X AWG 19
10 X 2 X AWG 19
14 X 2 X AWG 19

34,0
60,0
85,7
93,6
113,0
130,4
192,2
258,0
316,6

6,9
9,7
10,9
11,5
12,5
13,4
16,4
19,3
20,0

61
112
157
172
202
231
342
466
545

510 18 01
510 18 02
510 18 03
510 18 04
510 18 05

1 X 2 X 1,0
2 X 2 X 1,0
3 X 2 X 1,0
4 X 2 X 1,0
5 X 2 X 1,0

1 X 2 X AWG 18
2 X 2 X AWG 18
3 X 2 X AWG 18
4 X 2 X AWG 18
5 X 2 X AWG 18

42,0
73,0
93,6
117,8
139,0

7,3
10,3
11,4
12,3
13,3

71
129
169
204
237

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

89

CC-Schleppflex PUR-C-(TP)-512
Superflexible halogen-free data cable paired, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-(TP)-512 1020,5

CC-Schleppflex PUR-C-(TP)-512 shielded is used for


transmitting analogue and digital signals in power
supply chains, sensor technology and to connect
transmitters and sensors for measurement and control
technology. It can be used in- and outdoors where
aggressive and mineral oils occur and where the cable
is exposed to high mechanical stress. The overall
copper shield ensures exact data transmission and
protects the cable against electromagnetic
disturbances and influences. Coordinated twisted
lengths of the pairs ensure low coupling rates.
The PUR outer sheath is cut and notch resistant
and non-abrasive.

Technical data
Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Construction
Superfine strands of bare copper wires,
polyester (TPE) core insulation, core colours
acc. to DIN47100. Cores twisted in pairs,
tinned copper shield. PUR outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1 and IEC
60332-1), non-adhesive, resistant to hydrolysis and
microbes. Colour grey (RAL 7001).

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approval:

acc. to DIN VDE 0812

Cross-section (mm2):

0,25

0,50

0,75

1,0

Rated voltage (Volt):

300

300

300

300

1500

1500

1500

1500

Loop resistance (Ohm/km):

 158

 78

 52

 40

Operating capacity (nF/km) at 800 Hz:

approx. 80

approx. 77

approx. 75

Test voltage (Volt):

90

Temperature range:

flexible application:
fixed installation:

ConCab kabel connects the world

approx. 75

Part-No.

No. of cores
+
crosssection

Copper
weight

Outer
Weight
diameter
approx.

kg/km

mm

kg/km

512 0002 001


512 0002 002
512 0002 003
512 0002 004
512 0002 005
512 0002 006
512 0002 008
512 0002 010
512 0002 014

1 X 2 X 0,25
2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
14 X 2 X 0,25

14,0
31,0
40,6
45,0
50,6
73,5
78,3
94,0
113,5

4,9
6,0
6,5
6,9
8,1
8,6
9,8
10,6
12,0

36
46
57
73
88
102
118
165
204

512 0005 001


512 0005 002
512 0005 003
512 0005 004
512 0005 005
512 0005 006
512 0005 008
512 0005 010
512 0005 014

1 X 2 X 0,5
2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
5 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
14 X 2 X 0,5

38,4
51,8
70,4
77,0
78,2
104,0
142,0
173,0
227,0

5,6
7,7
8,6
9,2
10,2
11,0
12,2
14,3
15,5

45
102
134
155
183
208
264
315
383

512 0007 001


512 0007 002
512 0007 003
512 0007 004
512 0007 005
512 0007 006
512 0007 008
512 0007 010
512 0007 014

1 X 2 X 0,75
2 X 2 X 0,75
3 X 2 X 0,75
4 X 2 X 0,75
5 X 2 X 0,75
6 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
14 X 2 X 0,75

37,0
58,0
90,0
109,0
126,0
141,0
186,0
248,0
326,0

6,0
8,5
9,4
10,3
11,3
12,4
13,7
16,2
17,6

66
106
145
175
210
239
315
392
469

512 0010 001


512 0010 002
512 0010 003
512 0010 004
512 0010 005

1 X 2 X 1,0
2 X 2 X 1,0
3 X 2 X 1,0
4 X 2 X 1,0
5 X 2 X 1,0

41,0
78,0
91,0
121,0
145,0

6,2
8,9
9,8
10,8
11,8

81
138
181
224
255

With UL/CSA approval upon request

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

91

CC-Schleppflex PUR-C-(TP)-513
Low capacitance, superflexible halogen-free data cable paired, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Schleppflex-C-(TP)-513 8x 2 x 0,75 E244335 CUS AWM STYLE 20549 300V 80C

CC-Schleppflex PUR-C-(TP)-513 shielded UL/CSA


with low capacitance is used for the disturbance free
transmission of analogue and digital signals in power
supply chains, sensor technology and for the
connection of transmitters and sensors for
measurement and control technology.
It can be used where aggressive and mineral
oils occur and where the cable is exposed to high
mechanical stress. The overall copper shield ensures
exact data transmission and protects the cable against
electromagnetic disturbances and influences.
Coordinated twisting lengths of the pairs ensure low
coupling rates. The PUR outer sheath is cut and notch
resistant and non-abrasive.

Construction
Superfine strands of bare copper wires,
polyolefin core insulation, core colours
acc. to DIN47100. Cores twisted in pairs,
tinned copper shield. PUR outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operation capacity at 800 Hz:

core/core approx. 60 nF/km


core/shield approx. 160 nF/km

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0812


UL: Style 20549, 20233, CMX
CSA: AWM C22.2 N 210.2-M90 FT 1

Cross-section (mm2):

0,25

0,50

0,75

1,0

Rated voltage VDE / UL, CSA (Volt):

300

300

300

300

1500

1500

1500

1500

 158

 78

 52

 40

Test voltage (Volt):


Loop resistance (Ohm/km):

92

Technical data

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

513 26 01
513 26 02
513 26 03
513 26 04
513 26 05
513 26 06
513 26 08
513 26 10

1 X 2 X 0,14
2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
5 X 2 X 0,14
6 X 2 X 0,14
8 X 2 X 0,14
10 X 2 X 0,14

1 X 2 X AWG 26
2 X 2 X AWG 26
3 X 2 X AWG 26
4 X 2 X AWG 26
5 X 2 X AWG 26
6 X 2 X AWG 26
8 X 2 X AWG 26
10 X 2 X AWG 26

10,3
14,6
18,8
22,8
27,6
31,0
38,2
43,8

4,2
5,1
5,6
6,0
6,5
6,9
7,3
9,1

23
33
35
41
47
55
74
83

513 24 01
513 24 02
513 24 03
513 24 04
513 24 05
513 24 06
513 24 08
513 24 10
513 24 14

1 X 2 X 0,25
2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
14 X 2 X 0,25

1 X 2 X AWG 24
2 X 2 X AWG 24
3 X 2 X AWG 24
4 X 2 X AWG 24
5 X 2 X AWG 24
6 X 2 X AWG 24
8 X 2 X AWG 24
10 X 2 X AWG 24
14 X 2 X AWG 24

12,7
20,2
31,4
38,5
45,4
47,6
65,7
81,2
103,0

4,6
5,7
6,5
6,9
7,5
8,1
8,7
10,6
11,1

37
43
46
58
69
79
116
124
159

513 22 01
513 22 02
513 22 03
513 22 04
513 22 05
513 22 06
513 22 08
513 22 10

1 X 2 X 0,34
2 X 2 X 0,34
3 X 2 X 0,34
4 X 2 X 0,34
5 X 2 X 0,34
6 X 2 X 0,34
8 X 2 X 0,34
10 X 2 X 0,34

1 X 2 X AWG 22
2 X 2 X AWG 22
3 X 2 X AWG 22
4 X 2 X AWG 22
5 X 2 X AWG 22
6 X 2 X AWG 22
8 X 2 X AWG 22
10 X 2 X AWG 22

14,7
24,7
38,9
46,8
56,0
66,5
85,1
99,8

4,8
6,0
6,8
7,3
8,1
8,7
10,1
10,7

36
50
54
66
77
99
136
146

513 20 01
513 20 02
513 20 03
513 20 04
513 20 05
513 20 06
513 20 08
513 20 10
513 20 14

1 X 2 X 0,5
2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
5 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
14 X 2 X 0,5

1 X 2 X AWG 20
2 X 2 X AWG 20
3 X 2 X AWG 20
4 X 2 X AWG 20
5 X 2 X AWG 20
6 X 2 X AWG 20
8 X 2 X AWG 20
10 X 2 X AWG 20
14 X 2 X AWG 20

21,5
37,7
56,4
71,4
83,6
95,6
130,8
158,0
204,0

5,9
8,0
9,0
9,9
10,8
11,5
13,9
14,7
15,9

51
81
91
117
138
164
242
257
327

513 19 01
513 19 02
513 19 03
513 19 04
513 19 05
513 19 06
513 19 08
513 19 10
513 19 14

1 X 2 X 0,75
2 X 2 X 0,75
3 X 2 X 0,75
4 X 2 X 0,75
5 X 2 X 0,75
6 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
14 X 2 X 0,75

1 X 2 X AWG 19
2 X 2 X AWG 19
3 X 2 X AWG 19
4 X 2 X AWG 19
5 X 2 X AWG 19
6 X 2 X AWG 19
8 X 2 X AWG 19
10 X 2 X AWG 19
14 X 2 X AWG 19

37,6
49,1
73,5
90,3
108,0
132,9
170,6
203,0
294,1

6,5
8,6
10,1
10,9
12,1
13,1
15,4
16,3
18,7

108
113
121
147
179
207
307
327
435

513 18 01
513 18 02
513 18 03
513 18 04
513 18 05

1 X 2 X 1,0
2 X 2 X 1,0
3 X 2 X 1,0
4 X 2 X 1,0
5 X 2 X 1,0

1 X 2 X AWG 18
2 X 2 X AWG 18
3 X 2 X AWG 18
4 X 2 X AWG 18
5 X 2 X AWG 18

47,0
65,6
90,2
111,9
135,7

6,8
9,3
10,6
11,5
12,7

105
126
138
169
206

93

CC-Feedback and Sensor Cable PVC-C-251


Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt C-251 10x0,14+2x0,5

CC-Feedback and Sensor Cable PVC-C-251 is used for exact data and signal transmission for machinery
and control engineering. Additional cores ensure the power supply of each component. The PVC-based outer
sheath is flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).

Construction
LiYCY [10 X 0,14 + 2 X 0,5]
Fine strands of bare copper wire; PVC-based core
insulation, core colours acc. to DIN 47100.
At 0,5 mm2 colour repetition, cores twisted in layers,
foil wrapping, tinned drain wire, tinned copper shield,
PVCouter sheath.
LiYCY [10 X 0,14 + 4 X 0,5]
Construction as described under No. 1. Core colours
0,14 mm2: wh, bn, gn, ye, gy, pk, bu, rd, bk, vt.
Core colours 0,5 mm2: wh, bn, bu, bk.
Alternatively (part.-no- 242 1001 440): Core colours
acc. to DIN 47100 starting at 0,5 mm2.
LiYDY-CY [3 X (2 X 0,14) + 2 X 0,5]
Fine strands of bare copper wire,
PVC-based core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd, twisted
in pairs, tinned copper shield, PVC sheath.
Core colours 0,5 mm2: wh, bn. Cores and pairs
twisted together, foil wrapping, tinned drain wire,
overal tinned copper shield, PVC outer sheath.
LiYDY-CY [3 X (2 X 0,14) + 2 X (0,5)]
Fine strands of bare copper wires,
PVC-based core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd.
Core colours 0,5 mm2: wh, bn.
2
Pairs 0,14 mm : special core wrapping, tinned copper
shield, PVC sheath. Cores 0,5 mm2: foil wrapping,
tinned copper shield, PVC sheath, cores and pairs
twisted together, foil wrapping,
tinned drain wire, tinned copper shield,
PVC outer sheath.

94

LiYCY [15 X 0,14 + 4 X 0,5]


Construction as described under No. 1.
Core colours acc. to DIN 47100 starting at 0,5 mm2.
LiYCY [3 X 2 X 0,14 + 4 X 0,5]
Construction as described under No. 1.
Cores 0,14 mm2 twisted in pairs,
Core colours 0,14 mm2: bn/bk, gn/gy, pk/rd.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,14 + 4 X 0,5]
Construction as described under No.1.
Core colours 0,14 mm2: rd/bk, bn/gn, ye/vt, gy/pk.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,25 + 2 X 1]
Construction as described under No. 1.
Pair colours 0,25 mm2: rd/bk, bn/gn, gy/pk, bu/vt.
Core colours 1,0 mm2: wh, bn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,38 + 4 X 0,5]
Superfine copper strands acc. to DIN VDE 0295,
class 6. PVC-based core insulation. Core colours 0,5
mm2: bkwh, buwh, yewh, rdwh. Core colours 0,38
mm2: ye/gn, og/rd, bn/bk, bu/vt. Cores and pairs twisted together, foil wrapping, tinned drain wire, tinned
copper shield.
LiYCY [9 X 0,5 ] Feedback cable:
Construction described under No. 1.
Core colours: bu, wh, rd, pk, gn, ye, bn, bk, gy.

ConCab kabel connects the world

Part-No.

No. of cores

System

+
cross-section
251 1001 205
242 1001 440
251 1001 405
251 1501 405
252 3201 205
253 3201 205
251 3201 405
251 4201 405
251 4202 210
251 4203 405
251 905

LiYCY
LiYCY
LiYCY
LiYCY
LiYDY-DY
LiYDY-DY
LiYCY
LiYCY
LiYCY
LiYCY
LiYCY

[10 X 0,14 + 2 X 0,5]


[10 X 0,14 + 4 X 0,5]
[10 X 0,14 + 4 X 0,5]
[15 X 0,14 + 4 X 0,5]
[3 X (2 X 0,14) + 2 X 0,5]
[3 X (2 X 0,14) + 2 X (0,5)]
[3 X 2 X 0,14 + 4 X 0,5]
[4 X 2 X 0,14 + 4 X 0,5]
[4 X 2 X 0,25 + 2 X 1,0]
[4 X 2 X 0,38 + 4 X 0,5]
[9 X 0,5]

Heidenhain
Heidenhain
Bosch
Bosch
Indramat
Heidenhain
Heidenhain
Heidenhain
Indramat
Sinumerik
Indramat

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

46,1
56,0
56,0
60,0
61,0
69,6
50,5
59,5
72,0
81,5
73,0

8,0
8,2
8,2
8,8
8,0
8,0
8,0
8,0
8,8
9,9
8,8

75
95
95
140
100
110
98
96
120
145
125

Technical data
Rated voltage:

up to 0,38 mm2: 300 V


from 0,5 mm2: 500 V

Test voltage:
2000 V

Conductor stranding:

copper strands
acc. to DIN VDE 0295, class 5
or class 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:
-5C to +80C

Bending radius:

10 X cable diameter

Outer sheath colour:


grey (RAL 7001)

Approvals:

acc. to DIN VDE 0281, 0812


Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

95

CC-Feedback and Sensor Cable PVC-C-251


Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt - 251 3x2 x0,14 + 2x0,5 E 172073 c AWM STYLE 2464 300V 80C DESINA

CC-Feedback and Sensor Cable PVC-C-251 UL/CSA and DESINA-conforming, is used for exact data and signal
transmission for machinery- and control engineering. Additional cores ensure the power supply of each component.
The PVC-based outer sheath is flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), the sheat colour is according DESINA standard.

Construction
LiYCY [10 X 0,14 + 2 X 0,5]
Fine strands of bare copper wire; PVC-based core
insulation, core colours acc. to DIN 47100. At 0,5 mm2
colour repetition, cores twisted in layers, foil wrapping,
tinned drain wire, tinned copper shield, PVCouter
sheath. Colour DESINA green.
LiYCY [10 X 0,14 + 4 X 0,5]
Construction as described under No. 1. Core colours
0,14 mm2: wh, bn, gn, ye, gy, pk, bu, rd, bk, vt.
Core colours 0,5 mm2: wh, bn, bu, bk.
LiYCY [15 X 0,14 + 4 X 0,5]
Construction as described under No. 1.
Core colours acc. to DIN 47100 starting at 0,5 mm2.
LiYDY-CY [3 X (2 X 0,14) + 2 X 0,5]
Fine strands of bare copper wire,
PVC-based core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd, twisted in
pairs, tinned copper shield, PVC sheath.
Core colours 0,5 mm2: wh, bn. Cores and pairs
twisted together, foil wrapping, tinned drain wire,
overal tinned copper shield, PVC outer sheath.
LiYDY-CY [3 X (2 X 0,14) + 2 X (0,5)]
Fine strands of bare copper wires,
PVC-based core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd.
Core colours 0,5 mm2: wh, bn.
2
Pairs 0,14 mm : special core wrapping, tinned copper
shield, PVC sheath. Cores 0,5 mm2: foil wrapping,
tinned copper shield, PVC sheath, cores and pairs
twisted together, foil wrapping,
tinned drain wire, tinned copper shield,
PVC outer sheath.

96

LiYCY [3 X 2 X 0,14 + 4 X 0,5]


Construction as described under No. 1.
Cores 0,14 mm2 twisted in pairs.
Core colours 0,14 mm2: bn/bk, gn/gy, pk/rd.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,14 + 4 X 0,5]
Construction as described under No.1.
Core colours 0,14 mm2: rd/bk, bn/gn, ye/vt, gy/pk.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,25 + 2 X 1]
Construction as described under No. 1.
Pair colours 0,25 mm2: rd/bk, bn/gn, gy/pk, bu/vt.
Core colours 1,0 mm2: wh, bn.
Cores and pairs twisted together.
LiYCY [4 X 2 X 0,38 + 4 X 0,5]
Superfine copper strands acc. to DIN VDE 0295,
class 6. PVC-based core insulation. Core colours
0,5 mm2: bkwh, buwh, yewh, rdwh. Core colours
0,38 mm2: ye/gn, og/rd, bn/bk, bu/vt. Cores and
pairs twisted together, foil wrapping, tinned drain
wire, tinned copper shield.
LiYCY [9 X 0,5 ] Feedback cable:
Construction as described under No. 1.
Core colours: bu, wh, rd, pk, gn, ye, bn, bk, gy.

ConCab kabel connects the world

No. of cores

Part-No.

System

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

42,8
58,0
70,0
59,0
59,0
60,0
50,0
53,0
48,0
72,0
79,0
73,0

8,0
8,2
8,8
8,0
8,0
9,0
8,0
8,0
8,8
8,8
9,9
8,8

75
95
140
100
110
126
98
96
93
120
145
125

+
cross-section/AWG
251 1001 205 10
251 1001 405 10
251 1501 405 10
252 3201 205 10
253 3201 205 10
252 3201 4012 0510
251 3201 405 10
251 4201 405 10
251 4202 205 10
251 4202 210 10
251 4203 405 10
251 905 10

LiYCY
LiYCY
LiYCY
LiYDY-CY
LiYDY-CY
LiYDY-CY
LiYCY
LiYCY
LiYCY
LiYCY
LiYCY
LiYCY

[10 X 0,14/AWG 26 + 2 X 0,5/AWG 20]


[10 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[15 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[3 X (2 X 0,14/AWG 26) + 2 X 0,5/AWG 20]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
[3 X (2 X 0,14/AWG 26) + 4 X 0,14 + 2 X 0,5/AWG20]
[3 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
[4 X 2 X 0,38/AWG 22 + 4 X 0,5/AWG 20]
[9 X 0,5/AWG 20]

Heidenhain
Bosch
Bosch
Indramat
Heidenhain
Sinumerik
Heidenhain
Heidenhain
Indramat
Indramat
Sinumerik
Indramat

Technical Data
Rated voltage:

DIN VDE/IEC up to 0,38 mm2 : 300 V


from 0,50 mm2 : 500 V
UL/CSA : 300 V

Test voltage:
2000 V

Conductor stranding:

bare copper strands,


acc. to DIN VDE 0295, class 5 resp. 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:
-5C to +80C

Bending radius:

10 X cable diameter

Outer sheath colour:

DESINA-green (RAL 6018)

Approvals:

acc. to DIN VDE 0281, 0812


UL: Style 1061/2464
CSA: AWM
Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

97

CC-Feedback and Sensor Cable PUR-C-181


Superflexible halogen-free, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt C-181 90,5

CC-Feedback and Sensor Cable PUR-C-181 shielded is used for exact data and signal transmission for machine and
control engineering in power supply chains, handling equipment and robots. It can be used in- and outdoors. Additional
cores ensure the power supply of each component. The overall copper shield ensures exact signal transmission and
protects the cable against electromagnetic disturbances and influences. The PUR-based outer sheath is flame retardant
and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes, highly cut and notch resistant and non-abrasive.

Construction
LiF12YC11Y [10 X 0,14 + 2 X 0,5]
Superfine strands of bare copper wire. Polyester (TPE)
core insulation, core colours acc. to DIN 47100,
at 0,5 mm2 colour repetition, cores twisted in layers,
fleece, tinned drain wire, tinned copper shield,
PURouter sheath.
LiF12YC11Y [10 X 0,14 + 4 X 0,5]
Construction as described under No. 1. Core colours
0,14 mm2: wh, bn, gn, ye, gy, pk, bu, rd, bk, vt.
Core colours 0,5 mm2: wh, bn, bu, bk.
LiF12YC11Y [15 X 0,14 + 4 X 0,5]
Construction as described under No. 1.
Core colours acc. to DIN 47100 starting at 0,5 mm2.
LiF12YD12YC11Y [3 X (2 X 0,14) + 2 X (0,5)]
Part No. 183 3201 205
Superfine strands of bare copper wire
Polyester (TPE) core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd, twisted in
pairs, foil wrapping, tinned copper shield.
Polyester (TPE) sheath. Cores 0,5 mm2: wh, bn, each
core shielded, polyester (TPE) sheath.
Cores and pairs twisted together,
tinned drain wire, overall tinned copper shield,
PUR outer sheath.
Part No. 132 3201 205
Construction as Part No. 183 3201 205 except
core colours 0,14 mm2: gn/ye, rd/og, bk/bn.
Core colours 0,5 mm2: bk, rd.

98

LiF12YD12YC11Y [3 X (2 X 0,14) + 2 X 1,0]


Superfine strands of bare copper wires.
Polyester (TPE) core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, rd/bu,
twisted in pairs, tinned copper shield,
polyester (TPE) sheath.
Core colours 1,0 mm2: wh, bn,
cores and pairs twisted together in layers,
tinned drain wire, tinned copper shield,
PUR outer sheath.
LiF12YC11Y [4 X 2 X 0,14 + 4 X 0,5]
Construction as described under No. 1.
Core colours 0,14 mm2: bn/gn, ye/vt, gy/pk, rd/bk.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiF12YC11Y [4 X 2 X 0,25 + 2 X 1,0]
Construction as described under No. 1.
Core colours 0,25mm2: rd/bk, bn/gn, gy/pk, bu/vt.
Cores and pairs twisted together.
LiF12YC11Y [4 X 2 X 0,38 + 4 X 0,5]
Superfine strands of bare copper wires.
Polyester (TPE) core insulation.
Core colours 0,5 mm2: buwh, bkwh,rdwh,yewh.
Core colours 0,38 mm2: bk/bn, rd/or, ye/gn, bl/vt.
Cores and pairs twisted together, tinned drain wire,
tinned copper shield, PUR outer sheath.
LiF12YC11Y [9 X 0,5]
Construction as described under No. 1.
Core colours: bu, wh, rd, pk, gn, ye, bn, bk, gy.

No. of cores

Part-No.

Outer
sheath
colour

Copper Outer Weight


weight diameter
approx.

System

cross-section
181 1001 205
181 1001 405
181 1501 405
183 3201 205
132 3201 205
182 3201 210
181 4201 405
181 4202 205
181 4202 210
181 4203 405
131 4203 405
181 905
182 3201 401 205
142 3201 401
181 2201 8
181 4201 8
181 8201 8
181 1202 3
181 1220 25
182 4201 4
181 4201 402

LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YD12YC11Y
LiF12YD12YC11Y
LiF12YD12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YD12YC11Y
LiF12YC11Y

[10 X 0,14 + 2 X 0,5]


[10 X 0,14 + 4 X 0,5]
[15 X 0,14 + 4 X 0,5]
[3 X (2 X 0,14) + 2 X (0,5)]
[3 X (2 X 0,14) + 2 X (0,5)]
[3 X (2 X 0,14) + 2 X 1,0]
[4 X 2 X 0,14 + 4 X 0,5]
[4 X 2 X 0,25 + 2 X 0,5]
[4 X 2 X 0,25 + 2 X 1,0]
[4 X 2 X 0,38 + 4 X 0,5]
[4 X 2 X 0,38 + 4 X 0,5]
[9 X 0,5]
[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
[3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
[2 X 2 X 0,18]
[4 X 2 X 0,18]
[8 X 2 X 0,18]
[12 X 0,23]
[12 X (2 X 0,25)]
[ (4 X 2 X 0,14)]
[4 X 2 X 0,14 + 4 X 0,25]

Heidenhain
Bosch
Bosch
Heidenhain
Sinumerik
Heidenhain
Heidenhain
Indramat
Indramat
Sinumerik
Sinumerik
Indramat
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Heidenhain
Heidenhain

orange
orange
orange
orange
petrol
orange
orange
orange
orange
orange
petrol
orange
petrol
petrol
petrol
petrol
petrol
petrol
petrol
black
black

kg/km

mm

kg/km

46,1
56,0
60,7
74,0
82,0
61,4
55,3
63,0
72,0
81,5
81,5
73,0
71,5
84,1
18,7
32,4
71,3
59,0
115,0
32,3
38,5

8,0
8,0
8,8
9,4
9,7
8,8
8,2
8,8
8,8
8,6
8,6
8,8
9,0
10,3
5,6
6,7
8,6
7,1
12,5
6,1
6,1

70
85
103
104
105
108
109
124
134
203
203
125
126
148
38
56
125
132
206
91
95

Technical data
Rated voltage:

up to 0,38 mm2: 300 V


from 0,50 mm2: 500 V

Test voltage:
2000 V

Conductor stranding:

superfine bare copper strands,


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application: -40C up to +80C


fixed installation: -50C up to +80C

Bending radius:

10 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812

ConCab kabel connects the world

99

CC-Feedback and Sensor Cable PUR-C-181


Superflexible halogen-free, shielded
Conforms to EU low-voltage guideline 73/23/EEC

)
ConCab
kabel Mainhardt 181 3x2 x0,14 +2x0,5 E172073 cus AWM STYLE 20233 300V 80C DESINA

CC-Feedback and Sensor Cable PUR-C-181 shielded UL/CSA and DESINA conforming is used for exact data and
signal transmission for machinery and control engineering in power supply chains, handling equipment and robots. It can
be used in- and outdoors. Additional cores ensure the power supply of each component. The overall copper shield
ensures exact signal transmission and protects the cable against electromagnetic disturbances and influences. The
PUR-based outer sheath is flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 and EN 50265-21 resp. IEC 60332-1), non-adhesive, resistant to hydrolysis and microbes, highly cut and notch resistant and non-abrasive.

Construction
LiF12YC11Y [10 X 0,14/AWG 26 + 2 X 0,5/AWG 20]
Superfine strands of bare copper wire. Polyester (TPE)
core insulation, core colours acc. to DIN 47100,
at 0,5 mm2 colour repetition, cores twisted in layers,
tinned drain wire, tinned copper shield,
PURouter sheath. Colour DESINA-green.
LiF12YC11Y [10 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Construction as described under No. 1. Core colours
0,14 mm2: wh, bn, gn, ye, gy, pk, bu, rd, bk, vt.
Core colours 0,5 mm2: wh, bn, bu, bk.
LiF12YC11Y [15 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Construction as described under No. 1.
Core colours acc. to DIN 47100 starting at 0,5 mm2.
LiF12YD12YC11Y [3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
Part No. 183 3201 205 10
Superfine strands of bare copper wire. Polyester (TPE)
core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd,
twisted in pairs, tinned copper shield.
Polyester (TPE) sheath.
Core colours: 0,5 mm2: wh, bn, each core shielded, polyester (TPE) sheath. Cores and pairs twisted together,
tinned drain wire, overall tinned copper shield,
PUR outer sheath.
Part No. 132 3201 205 10
Construction as Part No. 183 3201 205 10 except
core colours 0,14 mm2: gn/ye, rd/og, bk/bn.
Core colours 0,5 mm2: bk, rd.

100

LiF12YD12YC11Y [3 X (2 X 0,14/AWG 26) + 2 X 1,0/AWG 18]


Superfine strands of bare copper wires.
Polyester (TPE) core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, rd/bu,
twisted in pairs, tinned copper shield.
Polyester (TPE) sheath.
Core colours 1,0 mm2: wh, bn,
cores and pairs twisted together in layers,
tinned drain wire, tinned copper shield,
PUR outer sheath.
LiF12YC11Y [4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Construction as described under No. 1.
Core colours 0,14 mm2: bn/gn, ye/vt, gy/pk, rd/bk.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiF12YC11Y [4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
Construction as described under No. 1.
Core colours 0,25mm2: rd/bk, bn/gn, gy/pk, bu/vt.
Cores and pairs twisted together.
LiF12YC11Y [4 X 2 X 0,38/AWG 22 + 4 X 0,5/AWG 20]
Superfine strands of bare copper wires.
Polyester (TPE) core insulation.
Core colours 0,5 mm2: buwh, bkwh,rdwh,yewh.
Core colours 0,38 mm2: bk/bn, rd/or, ye/gn, bl/vt.
Cores and pairs twisted together, tinned drain wire,
tinned copper shield, PUR outer sheath.
LiF12YC11Y [9 X 0,5/AWG 20]
Construction as described under No. 1.
Core colours: bu, wh, rd, pk, gn, ye, bn, bk, gy.

No. of cores

Part-No.

System

+
cross-section/AWG
181 1001 205 10
181 1001 405 10
181 1501 405 10
183 3201 205 10
132 3201 205 10
182 3201 210 10
181 4201 405 10
181 4202 205 10
181 4202 210 10
181 4203 405 10
181 905 10
182 3201 401 205 10
142 3201 401 10
181 2201 8 10
181 4201 8 10
181 8201 8 10
181 1202 3 10
182 1220 25 10
182 4201 4 00
181 4201 402 00

[10 X 0,14/AWG 26 + 2 X 0,5/AWG 20]


[10 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[15 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
[3 X (2 X 0,14/AWG 26) + 2 X 1,0/AWG 18]
[4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
[4 X 2 X 0,38/AWG 21 + 4 X 0,5/AWG 20]
[9 X 0,5/AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 2 X AWG 20]
LiF12YD12YC11Y [3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 4 X AWG 24 + 2 X AWG 20]
[2 X 2 X 0,18/AWG 25]
LiF12YC11Y
[4 X 2 X 0,18/AWG 25]
LiF12YC11Y
[8 X 2 X 0,18/AWG 25]
LiF12YC11Y
[12 X 0,23/AWG 24]
LiF12YC11Y
[12X (2 X 0,25/AWG 24)]
LiF12YD12Y11Y
LiF12YD12YC11Y [(4 X 2 X 0,14/AWG 26)] black
[4 X 2 X 0,14/AWG 26 + 4 X 0,25/AWG 24] black
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YD12YC11Y
LiF12YD12YC11Y
LiF12YD12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YC11Y
LiF12YD12YC11Y

Copper Outer Weight


weight diameter
approx.
mm
kg/km
kg/km

Heidenhain
Heidenhain
Bosch
Heidenhain
Sinumerik
Heidenhain
Heidenhain
Indramat
Indramat
Sinumerik
Indramat
Sinumerik

46,1
56,0
60,7
74,0
82,0
61,4
55,3
63,0
72,0
81,5
73,0
71,5

8,0
8,0
8,8
9,4
9,7
8,8
8,2
8,8
8,8
8,6
8,9
9,0

70
85
103
104
105
108
109
124
134
203
125
126

Sinumerik

84,1

10,3

148

Sinumerik
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Heidenhain
Heidenhain

23,5
32,4
71,3
59,0
115,0
32,3
38,5

5,6
6,7
8,6
7,1
12,5
7,0
6,1

44
56
125
132
206
91
95

Technical data
Rated voltage:

Bending radius:

DIN VDE/IEC: up to 0,38 mm2: 300 V


from 0,50 mm2: 500 V
UL/CSA: 300 V

Test voltage:

10 X cable diameter

Outer sheath colour:

DESINA-green (RAL 6018)

2000 V

Conductor stranding:

superfine bare copper strands,


acc. to DIN VDE 0295, class 6

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 10042/20233
Style 10263/20234
CSA: AWM I A/B, II A/B, FT 1

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application: -40C up to +80C


fixed installation: -50C up to +80C

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

101

CC-Feedback and Sensor Cable PUR-C-281


Low capacitance superflexible halogen-free, shielded
Conforms to EU low-voltage guideline 73/23EEC

)ConCab kabel Mainhardt 281 4x 2 x0,14 +4x0,5 E172073 cus AWM STYLE 20233 300V 80C DESINA

CC-Feedback and Sensor Cable PUR-C-281 shielded UL/CSA and DESINA conforming is used for exact data and signal transmission with low capacity for machinery and control engineering in power supply chains, handling equipment
and robots. It can be used in- and outdoors. Additional cores ensure the power supply of each component. The overall
copper shield ensures exact signal transmission and protects the cable against electromagnetic disturbances and
influences. The PUR-based outer sheath is flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1
and EN 50265-2-1 resp. IEC 60332-1), non-adhesive, resistant to hydrolysis and microbes, highly cut and notch resistant
and non-abrasive.

Construction
LiF9YC11Y [10 X 0,14/AWG 26 + 2 X 0,5/AWG 20]
Superfine strands of bare copper wire. Polypropylen (PP)
core insulation, core colours acc. to DIN 47100,
at 0,5 mm2 colour repetition, cores twisted in layers,
tinned drain wire, tinned copper shield,
PURouter sheath. Colour DESINA-green.
LiF9YC11Y [10 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Construction as described under No. 1. Core colours
0,14 mm2: wh, bn, gn, ye, gy, pk, bu, rd, bk, vt.
Core colours 0,5 mm2: wh, bn, bu, bk.
LiF9YD12YC11Y [3 X (2 X 0,14/AWG 26) + 2 X 1,0/AWG 18]
Superfine strands of bare copper wires.
Polypropylen core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, rd/bu,
twisted in pairs, tinned copper shield,
polyester (TPE) sheath.
Core colours 1,0 mm2: wh, bn,
cores and pairs twisted together in layers,
tinned drain wire, tinned copper shield,
PUR outer sheath.

102

.
LiF9YC11Y [4 X 2 X 0,14/AWG 26 + 4 X 0,25/AWG 24]
Construction as described under No. 1.
Core colours 0,14 mm2: bn/gn, ye/vt, gy/pk, rd/bk.
Core colours 0,25 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiF9YC11Y [4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Construction as described under No. 1.
Core colours 0,14 mm2: bn/gn, ye/vt, gy/pk, rd/bk.
Core colours 0,5 mm2: wh, bu, whgn, bngn.
Cores and pairs twisted together.
LiF9YC11Y [4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20 +
( 4 X 0,14/AWG 26)]
Superfine strands of bare copper wires.
Polypropylen core insulation.
Core colours 4 x 2 x 0,14 mm2: bn/gn, vt/ye, gy/pk, bl/bk.
Core colours 4 x 0,5 mm2: bngn, whgn, bl, wh.
Core colours 4 x 2 x 0,14 mm2: yebk, rdbk, gnbk, blbk,
twisted in pairs, tinned copper shield,
polyester (TPE) sheath.
cores and pairs twisted together in layers,
overall tinned copper shield, PUR outer sheath.

ConCab kabel connects the world

No. of cores

Part-No.

System

+
cross-section/AWG
281 1001 205 10
281 1001 405 10
283 3201 205 10
282 3201 210 10
281 4201 405 10
282 4201 4 00
281 4201 402 00
281 4201 402 10
281 4201 405 401 10
281 4201 405 401 00

LiF9YC11Y
LiF9YC11Y
LiF9YD12YC11Y
LiF9YD12YC11Y
LiF9YC11Y
LiF9YD12YC11Y
LiF9YC11Y
LiF9YC11Y
LiF9YC11Y
LiF9YC11Y

[10 X 0,14/AWG 26 + 2 X 0,5/AWG 20]


[10 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
[3 X (2 X 0,14/AWG 26) + 2 X 1,0/AWG 18]
[4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[(4 X 2 X 0,14/AWG 26)] black
[4 X 2 X 0,14/AWG 26 + 4 X 0,25/AWG 24] black
[4 X 2 X 0,14/AWG 26 + 4 X 0,25/AWG 24]
[4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20 + ( 4 X 0,14/AWG 26)]
[4 X 2 X 0,14/AWG 26 + 4 X 0,5/AWG 20 + ( 4 X 0,14/AWG 26)] black

Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain

Copper Outer Weight


weight diameter
approx.
kg/km

mm

kg/km

46,1
56,0
74,0
61,4
55,3
46,5
41,0
41,0
71,0
71,0

8,0
8,0
9,4
8,8
8,2
7,0
7,1
7,1
8,3
8,3

70
85
104
108
109
91
95
95
125
125

Technical data
Rated voltage:

Bending radius:

DIN VDE/IEC up to 0,38 mm2: 300 V


from 0,50 mm2: 500 V
UL/CSA: 300 V

Test voltage:
2000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

10 X cable diameter

Outer sheath colour:

DESINA-green (RAL 6018)


or black

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 20233, 20234
CSA: AWM I A/B, II A/B, FT 1

Operating capacity at 800 Hz:


core/core approx. 70 nF/km
core/shield approx. 110 nF/km

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application: -40C up to +80C


fixed installation: -50C up to +80C

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

103

CC-Feedback and Sensor Cable PUR-C-281


Low capacitance superflexible halogen-free, shielded
Conforms to EU low-voltage guideline 73/23EEC

)ConCab kabel Mainhardt 281 4x 2 x0,14 +4x0,5 E172073 cus AWM STYLE 20233 300V 80C DESINA

CC-Feedback and Sensor Cable PUR-C-281 shielded UL/CSA and DESINA conforming is used for exact data and signal transmission with low capacity for machinery and control engineering in power supply chains,
handling equipment and robots. It can be used in- and outdoors. Additional cores ensure the power supply of each
component. The overall copper shield ensures exact signal transmission and protects the cable against
electromagnetic disturbances and influences. The PUR-based outer sheath is flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1 and EN 50265-2-1 resp. IEC 60332-1), non-adhesive, resistant to
hydrolysis and microbes, highly cut and notch resistant and non-abrasive.

Construction
LiF9YC11Y [15 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
Superfine strands of bare copper wire. Polypropylen (PP)
core insulation, core colours acc. to DIN 47100,
at 0,5 mm2 colour repetition, cores twisted in layers,
tinned drain wire, tinned copper shield,
PURouter sheath. Colour DESINA-green.
LiF9YC11Y [2 X 2 X 0,15/AWG 26 + 2 X 0,38/AWG 21]
Superfine strands of bare copper wire.
Polypropylen (PP) core insulation.
Core colours at 0,15 mm2 : gn/ye, pk/bl.
Core colours at 0,38 mm2 : bk and red.
Cores twisted in layers, tinned drain wire, tinned copper
shield, PURouter sheath. Colour DESINA-green.
LiF9YD12YC11Y
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
Part No. 283 3201 205 10
Superfine strands of bare copper wire.
Polypropylen core insulation.
Core colours 0,14 mm2: gn/ye, gy/pk, bu/rd, twisted in
pairs, foil wrapping, tinned copper shield.
Polyester (TPE) sheath.
Cores 0,5 mm2: wh, bn, each core shielded, polyester
(TPE) sheath. Cores and pairs twisted together, fleece,
tinned drain wire, overall tinned copper shield,
PUR outer sheath.
Part No. 232 3201 205 10
Construction as Part No. 283 3201 205 10 except
core colours 0,14 mm2: gn/ye, rd/og, bk/bn. Core
colours 0,5 mm2: bk, rd.

104

LiF9YC11Y [4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]


Construction as described under No. 1.
Core colours 0,25mm2: rd/bk, bn/gn, gy/pk, bu/vt.
Cores and pairs twisted together.
LiF9YC11Y [4 X 2 X 0,38/AWG 22 + 4 X 0,5/AWG 20]
Superfine strands of bare copper wires,
polypropylen core insulation.
Core colours 0,5 mm2: buwh, bkwh,rdwh,yewh.
Core colours 0,38 mm2: bk/bn, rd/or, ye/gn, bl/vt.
Cores and pairs twisted together, fleece, tinned drain wire,
tinned copper shield, PUR outer sheath.
LiF9YC11Y [9 X 0,5/AWG 20]
Construction as described under No. 1.
Core colours: bu, wh, rd, pk, gn, ye, bn, bk, gy.
LiF9YC11Y [4 X 1,0 /AWG 18+ 4 X 2 X 0,14/AWG 26 +
(4 X 0,14/AWG 26)]
Superfine strands of bare copper wires,
polypropylen core insulation.
Core colours 1 mm2: wh, bu, bngn, whgn.
Core colours 4 x 0,14 mm2: yebk, bubk, gnbk, rdbk.
Core colours 4 x 2 x 0,14 mm2: rd/bk, bn/gn, vt/ye, wh/gn,
tinned copper shield.
Cores and pairs twisted together, overall tinned copper
shield, PUR outer sheath.

ConCab kabel connects the world

No. of cores

Part-No.

System

+
cross-section/AWG
[15 X 0,14/AWG 26 + 4 X 0,5/AWG 20]
[2 X 2 X 0,15/AWG 26) + 2 X 0,38/AWG 21)]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)]
[2 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
[2 X (2 X 0,25/AWG 24)StC + 2 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
[4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
[4 X 2 X 0,38/AWG 21 + 4 X 0,5/AWG 20]
[9 X 0,5/AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
LiF9YD12YC11Y [3 X (2 X AWG 26) + 4 X AWG 26 + 2 X AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
242 3201 401 10
[3 X (2 X AWG 26) + 4XAWG 26 + 4 XAWG 24 + 2 XAWG 20]
LiF9YC11Y
[2 X 2 X 0,18/AWG 25]
LiF9YC11Y
281 2201 8 10
[4 X 2 X 0,18/AWG 25]
LiF9YC11Y
281 4201 8 10
[8 X 2 X 0,18/AWG 25]
LiF9YC11Y
281 8201 8 10
[12 X 0,23/AWG 24]
LiF9YC11Y
281 1202 3 10
[12X (2 X 0,25/AWG 24)]
LiF9YC11Y
281 1220 25 10
[4 X 1,0 /AWG 18+ 4 X 2 X 0,14/AWG 26 + (4 X 0,14/AWG 26)]
281 4104 201 401 10 LiF9YC11Y
281 1501 405 10
281 2201 203 10
232 3201 205 10
282 2202 205 10
281 2202 205 10
281 4202 205 10
281 4202 210 10
281 4203 405 10
281 905 10
282 3201 401 205 10

LiF9YC11Y
LiF9YC11Y
LiF9YD12YC11Y
LiF9YC11Y
LiF9YD12YC11Y
LiF9YC11Y
LiF9YC11Y
LiF9YC11Y
LiF9YD12YC11Y

Copper Outer Weight


weight diameter
approx.
kg/km

mm

kg/km

Bosch
Sinumerik
Sinumerik
Indramat
Indramat
Indramat
Indramat
Sinumerik
Indramat
Sinumerik

60,7
28,0
82,0
35,0
46,0
63,0
72,0
81,5
62,3
71,5

8,8
7,0
9,7
7,6
8,7
8,8
8,8
8,6
8,8
9,0

127
60
105
92
90
124
134
203
125
126

Sinumerik

84,1

10,3

148

Sinumerik
Sinumerik
Sinumerik
Sinumerik
Sinumerik
Indramat

18,7
32,4
71,3
59,0
115,0
86,8

5,6
6,5
8,6
7,1
12,5
9,7

38
56
125
132
206
140

Technical data
Rated voltage:

Bending radius:

DIN VDE/IEC up to 0,38 mm2: 300 V


from 0,50 mm2: 500 V
UL/CSA: 300 V

Test voltage:

10 X cable diameter

Outer sheath colour:

DESINA-green (RAL 6018)

2000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 20233, 20234
CSA: AWM I A/B, II A/B, FT 1

Operating capacity at 800 Hz:


core/core approx. 70 nF/km
core/shield approx. 110 nF/km

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application: -40C up to +80C


fixed installation: -50C up to +80C

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

105

CC-Servo PVC-586
Motor-supply cable 0.6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt - SERVO 586 4 G 2,5 E 172073 c AWM STYLE 20886 1000V DESINA

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

Fine copper strands


acc. to DIN VDE 0295, class 5
CC-Servo PVC-586 is used to connect servo- and
DNC-motors. The cable is DESINA conforming and
can be used for occasional flexible applications.

Construction
Fine strands of bare copper wires, PVC or PP core
insulation, cores are black with consecutive white
numbering and a green/yellow protective
conductor in the outer layer, cores twisted in
layers, PVC-based outer sheath, UV-resistant,
resistant to oil and coolants, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001) or
DESINA-black (RAL 9005).

106

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

-30C to +80C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0281


cUL: Style 20886
CSA: AWM I A/B , II A/B, FT 1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

586 0015 004


586 0025 004
586 0025 007
586 0040 004
586 0060 004
586 0100 004
586 0160 004
586 0250 004

4 G 1,5
4G 2,5
7 G 2,5
4 G 4
4 G 6
4 G 10
4G 16
4G 25

586 160 400


586 160 700
586 140 400
586 140 500
586 120 400
586 120 500
586 100 400
586 080 400
586 060 400
586 040 400
586 020 400
586 010 400

4 G 1,5
7 G 1,5
4G 2,5
5 G 2,5
4 G 4
5 G 4
4 G 6
4 G 10
4G 16
4G 25
4 G 35
4 G 50

No. of cores
+
AWG
+ 

4X
7X
4X
5X
4X
4X
4X
4X
4X
4X
4X
4X

AWG 16
AWG 16
AWG 14
AWG 14
AWG 12
AWG 12
AWG 10
AWG 8
AWG 6
AWG 4
AWG 2
AWG 1

Outer
sheath
color

Copper
weight

Outer
diameter
approx.

Weight

kg/km

ca. mm

kg/km

grey
grey
grey
grey
grey
grey
grey
grey

58
96
168
154
230
384
614
960

9,2
11,8
15,0
13,0
16,0
20,0
24,0
31,0

126
217
315
329
445
660
1057
1805

black
black
black
black
black
black
black
black
black
black
black
black

58
101
96
120
154
192
230
384
614
960
1344
1920

9,5
12,7
10,5
11,6
11,9
13,4
13,9
18,4
24,8
27,3
30,6
36,3

139
173
203
251
310
415
430
790
1100
1600
2096
2960

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

107

CC-Servo PVC-C-585
Motor supply cable 0.6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servo-585 4G4 E172073 CUS AWM STYLE 20886 0,6/1kV 80C DESINA

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

CC-Servo PVC-585 shielded UL/CSA and DESINA


conforming is used for frequence converters and to
connect servo and DNC-motors. The overall copper
shield enables the cable to be used for applications in
which high protection against electromagnetic disturbances are required. The cable can be used for occasional flexible applications.

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5
or acc. class 6

Insulation resistance:

min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core
insulation, cores are black with consecutive white
numbering and a green/yellow protective conductor,
cores twisted together in layers. PVC inner sheath
resp. UL/CSA version without inner sheath, tinned
copper shield. PVC-based outer sheath,
resistant to oil and coolants, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1). Colour
grey (RAL 7001) or DESINA-orange (RAL 2003).

108

Temperature range:

fixed installation:
flexible application:

-30C to +80C
-5C to +70C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0281


cUL: Style 20886
CSA: AWM I A/B , II A/B, FT 1

ConCab kabel connects the world

Part-No.

No. of cores
+
cross
section

No. of cores
+
AWG
+ 

Outer
sheath
colour

Copper
weight

Outer
diameter
approx.

Weight

kg/km

ca. mm

kg/km

585 0015 004


585 0025 004
585 0040 004
585 0060 004
585 0100 004
585 0160 004
585 0250 004
585 0350 004

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35

grey
grey
grey
grey
grey
grey
grey
grey

27,0
177,0
254,0
341,0
577,0
838,0
1214,0
1618,0

13,0
13,1
15,0
19,8
25,1
27,3
34,0
37,2

244
357
529
617
1042
1464
1918
2510

585 0015 048


585 0025 048
585 0040 048
585 0060 048
585 0100 048
585 0160 048
585 0250 048
585 0350 048
585 0500 048

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

orange
orange
orange
orange
orange
orange
orange
orange
orange

127,0
177,0
254,0
341,0
577,0
838,0
1214,0
1618,0
2397,0

12,7
14,8
15,0
19,3
25,1
27,3
34,0
36,3
43,4

244
357
529
617
1042
1464
1918
2510
3785

585 1604 08
585 1404 08
585 1204 08
585 1004 08
585 0804 08
585 0604 08
585 0404 08
585 0204 08
585 0104 08

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

orange
orange
orange
orange
orange
orange
orange
orange
orange

94,7
143,8
207,6
311,2
483,6
739,0
1120,0
1544,0
2128,6

10,1
11,3
13,0
15,2
19,7
25,8
28,3
32,2
41,0

132
182
274
380
602
859
1343
1852
2600

4 X AWG 16
4 X AWG 14
4 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6
4 X AWG 4
4 X AWG 2
4 X AWG 1

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

109

CC-Servo 2Y-(St)-CY-587
CC-Servo 2Y-(St)-CH-1587
Low capacitance cable for frequency converters 0,6/1kV, double shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servo-CY-587 0,6/1kV

Technical data
Rated voltage:
CC-Servo 2Y-(St)-CY-587 and
CC-Servo 2Y-(St)-CH-1587 double shielded are
designed for application with high EMC
requirements to connect motors and frequency
converters and can be used for medium strain
application in dry and damp areas but not outdoors.
The low capacitance PE core insulation
allows a disturbance free application in
frequency converters, servo and DNC-motors
especially where longer cable lengths are needed.
For optimized EMC-Design, cables with three core
protective conductor should be used.

600/1000 V

Test voltage:
4000 V

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

min. 20 MOhm X km

Coupling resistance:

Construction
Fine strands of bare copper wires. PE (polyethylene)
core insulation, core colours acc. to DIN VDE 0293,
part 308 with one (or three) green/yellow protective
conductor(s). Cores twisted in layers, aluminium foil,
tinned copper shield. PVC-based or halogen-free
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1).
Colours please see table next page.

110

max. 250 Ohm/km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-30C to +80C
-5C to +70C

Bending radius:

15 X cable diameter

Approvals:
acc. to DIN VDE 0281

Part-No.

No. of cores
+

Outer sheath
colour

cross-section
587 0015 004
587 0025 004
587 0040 004
587 0060 004
587 0100 004
587 0160 004
587 0250 004
587 0350 004
587 0500 004
587 0700 004
587 0950 004

Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY
Li2Y(St)CY

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50
4 G 70
4 G 95

transparent
transparent
transparent
transparent
transparent
transparent
transparent
transparent
transparent
transparent
transparent

Operating
capacity
approx.

Copper
weight

Outer
diameter
approx.

Weight

nF/km

kg/km

mm

kg/km

105
125
150
165
195
240
260
280
320
360
410

87,0
133,0
213,0
298,0
492,0
726,0
1118,0
1662,0
2345,0
3196,0
4316,0

10,8
12,4
14,6
17,5
19,8
23,5
27,4
31,9
37,4
42,0
47,4

140
298
486
625
863
1285
1871
2616
2935
3941
5286

86,0
144,0
224,0
298,0
511,0
751,0
1204,0
1535,0
2156,0
2980,0
3530,0
4276,0
5488,0
6835,0
8851,0
10881,0

10,2
11,9
14,1
15,8
19,0
22,5
26,0
29,5
35,0
38,5
44,0
48,0
53,0
57,5
66,0
73,0

140
220
323
420
615
898
1325
1718
2402
3056
4165
5074
6128
7475
9491
11521

10,2
11,9
14,1
15,8
19,0
22,5
26,0
29,5
35,0
38,5
44,0
48,0
53,0
57,5
66,0
73,0

140
220
323
420
615
898
1325
1718
2402
3056
4165
5074
6128
7475
9491
11521

CC-Servo 2Y-(St)-CY-587 for optimized EMC-Design


587 30015 002 00
587 30025 005 00
587 30040 007 00
587 30060 010 00
587 30100 015 00
587 30160 025 00
587 30250 040 00
587 30350 060 00
587 30500 100 00
587 30700 100 00
587 30950 160 00
587 31200 160 00
587 31500 250 00
587 31850 350 00
587 32400 425 00
587 33000 500 00

Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB
Li2Y(St)CY-JB

3 X 1,5 + 3 X 0,25
3 X 2,5 + 3 X 0,5
3 X 4 + 3 X 0,75
3X6+3X1
3 X 10 + 3 X 1,5
3 X 16 + 3 X 2,5
3 X 25 + 3 X 4
3 X 35 + 3 X 6
3 X 50 + 3 X 10
3 X 70 + 3 X 10
3 X 95 + 3 X 16
3 X 120 + 3 X 16
3 X 150 + 3 X 25
3 X 185 + 3 X 35
3 X 240 + 3 X 42,5
3 X 300 + 3 X 50

black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black

215
235
250
270
290
305
315
325
335
345
360

CC-Servo 2Y-(St)-CH-1587 for optimized EMC-Design halogen-free


1 587 30015 002 05
1 587 30025 005 05
1 587 30040 007 05
1 587 30060 010 05
1 587 30100 015 05
1 587 30160 025 05
1 587 30250 040 05
1 587 30350 060 05
1 587 30500 100 05
1 587 30700 100 05
1 587 30950 160 05
1 587 31200 160 05
1 587 31500 250 05
1 587 31850 350 05
1 587 32400 425 05
1 587 33000 500 05

Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB
Li2Y(St)CH-JB

3 X 1,5 + 3 X 0,25
3 X 2,5 + 3 X 0,5
3 X 4 + 3 X 0,75
3X6+3X1
3 X 10 + 3 X 1,5
3 X 16 + 3 X 2,5
3 X 25 + 3 X 4
3 X 35 + 3 X 6
3 X 50 + 3 X 10
3 X 70 + 3 X 10
3 X 95 + 3 X 16
3 X 120 + 3 X 16
3 X 150 + 3 X 25
3 X 185 + 3 X 35
3 X 240 + 3 X 42,5
3 X 300 + 3 X 50

grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey

215
235
250
270
290
305
315
325
335
345
360

86,0
144,0
224,0
298,0
511,0
751,0
1204,0
1535,0
2156,0
2980,0
3530,0
4276,0
5488,0
6835,0
8851,0
10881,0

Special needs, different dimensions or different outer sheath colours upon request.

111

CC-Servoflex PUR-580
Superflexible halogen-free motor-supply cable 0,6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-580 4G25 0,6/1kV

Technical data
Rated voltage:
CC-Servoflex PUR-580 is designed to connect servo
and DNC-motors. It is used as a supply cable for
power supply chains, automatic handling equipment
and robots for in- and outdoors. It is used in areas
where aggressive and mineral oils or high mechanical
stress occur. A special cable
structure and high quality materials ensure a long
service life. The PUR outer sheath is cut
and notch resistant and non-abrasive.

600/1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

Construction
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering and green/yellow
protective conductor. PUR-based outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1), non-adhesive, resistant to
hydrolysis and microbes.
Colour grey (RAL 7001) or petrol.

112

min. 100 MOhm X km

Temperature range:

flexible installation:
fixed installation:

ConCab kabel connects the world

-40C to +80C
-50C to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Outer
sheath
colour

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

580 0015 004


580 0025 004
580 0040 004
580 0060 004
580 0100 004
580 0160 004
580 0250 004
580 0350 004
580 0500 004

4 G 1,5
4 G 2,5
4G 4
4G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

grey
grey
grey
grey
grey
grey
grey
grey
grey

58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0

8,8
10,2
11,6
13,2
16,5
19,2
24,1
27,5
36,0

121
209
306
451
744
1210
1505
2086
2923

580 0015 041


580 0025 041
580 0040 041
580 0060 041
580 0100 041
580 0160 041
580 0250 041
580 0350 041
580 0500 041

4 G 1,5
4 G 2,5
4G 4
4G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol

58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0

8,5
10,2
11,6
13,2
16,5
19,2
24,5
28,0
35,5

121
209
306
451
744
1210
1505
2086
2923

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

113

CC-Servoflex PUR-580
Superflexible halogen-free motor-supply cable 0,6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-580 4G4 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

DINVDE/IEC:
UL/CSA:
CC-Servoflex PUR-580
UL/CSA and DESINA conforming is designed
to connect servo and DNC-motors. It is used as
a supply cable in power supply chains, automatic
handling equipment and robots. It can be used in- and
outdoors and in areas where agressive and mineral
oils or high mechanical stress occur. A special cable
structure and high quality materials ensure a long
service life. The polyurethane outer sheath is cut and
notch resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering and green/yellow
protective conductor. PUR-based outer sheath is UVresistant, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1),
non-adhesive, and resistant to hydrolysis and
microbes. Colour DESINA-black (RAL 9005).

114

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible installation:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10264/20234
CSA: AWM I A/B, II A/BFT1

ConCab kabel connects the world

Part-No.

580 160 400


580 140 400
580 120 400
580 100 400
580 080 400
580 060 400
580 040 400
580 020 400
580 010 400

No. of cores

No. of cores

+
crosssection

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

4 X AWG 16
4 X AWG 14
4 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6
4 X AWG 4
4 X AWG 2
4 X AWG 1

58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0

8,8
10,2
11,6
13,2
16,5
19,2
24,5
28,0
35,5

121
209
306
451
744
1210
1505
2086
2923

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

115

CC-Servoflex PUR-C-581
Superflexible halogen-free motor-supply cable 0,6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-C-581 4G16 0,6/1kV

CC-Servoflex PUR-C-581 shielded is designed to


connect electronically controlled servo and
DNC-motors and frequency converters. It is used in
power supply chains, automatic handling equipment
and robots. It can be used in- and outdoors and where
aggressive and mineral oils occur. A special cable
structure and high quality materials ensure a long
service life of CC-Schleppflex PUR-C-581.
Due to the overall copper shield the cable meets the
electromagnetic compatibility (EMC) requirements
and ensures a disturbance-free operation of servo and
DNC motors. The polyurethane outer sheath is highly
cut and notch resistant and non-abrasive.

superfine copper strands


acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:

Superfine strands of bare copper wire, polyester


(TPE) core insulation, cores are black with
consecutive white numbering and green/yellow
protective conductor, tinned copper shield.
PUR-based outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001), petrol
or DESINA- orange (RAL 2003).

116

Technical data
Rated voltage:
600/1000 V

Test voltage:
4000 V

Conductor stranding:

min. 100 MOhm X km

Temperature range:

flexible installation:
fixed installation:

ConCab kabel connects the world

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Outer
sheath
colour

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

581 0015 004


581 0025 004
581 0040 004
581 0060 004
581 0100 004
581 0160 004
581 0250 004
581 0350 004
581 0500 004

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

grey
grey
grey
grey
grey
grey
grey
grey
grey

104,0
164,0
245,0
337,0
528,0
790,0
1249,0
1653,0
2286,0

9,0
10,7
12,2
14,0
17,3
20,2
24,9
28,7
36,2

173
239
321
457
695
1126
1648
2206
3146

581 0015 041


581 0025 041
581 0040 041
581 0060 041
581 0100 041
581 0160 041
581 0250 041
581 0350 041
581 0500 041

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol

104,0
164,0
245,0
337,0
528,0
790,0
1249,0
1653,0
2286,0

9,0
10,7
12,2
14,0
17,3
20,2
24,9
28,7
36,2

173
239
321
457
695
1126
1648
2206
3146

581 0015 048


581 0025 048
581 0040 048
581 0060 048
581 0100 048
581 0160 048
581 0250 048
581 0350 048
581 0500 048

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

orange
orange
orange
orange
orange
orange
orange
orange
orange

104,0
164,0
245,0
337,0
528,0
790,0
1249,0
1653,0
2286,0

9,0
10,7
12,2
14,0
17,3
20,2
24,9
28,7
36,2

173
239
321
457
695
1126
1648
2206
3146

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

117

CC-Servoflex PUR-C-581
Superflexible halogen-free motor-supply cable 0,6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

- kabel Mainhardt Servoflex-C-581 4G4 E172073 CUS AWM STYLE 20234 1000V 80C DESINA
ConCab

CC-Servoflex PUR-C-581 shielded, UL/CSA and


DESINA conforming is designed to connect
electronically controlled servo and DNC-motors and
frequency converters. It is used in power supply
chains, automatic handling equipment and robots. It
can be used in- and outdoors and where aggressive
and mineral oils occur. A special cable structure and
high quality materials ensure a long service life of
CC-Schleppflex PUR-C-581.
Due to the overall copper shield the cable meets the
electromagnetic compatibility (EMC) requirements
and ensures a disturbance free operation of servo and
DNC-motors. The polyurethane outer sheath is highly
cut and notch resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering and green/yellow
protective conductor, tinned copper shield.
PUR outer sheath, flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1), non-adhesive and
resistant to hydrolysis and microbes.
Colour DESINA-orange (RAL 2003).

118

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible installation:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10264, 20234
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

581 180 408


581 160 408
581 140 408
581 120 408
581 100 408
581 080 408
581 060 408
581 040 408
581 020 408
581 010 408

No. of cores

No. of cores

+
crosssection

+
AWG

4 G 1,0
4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

4 X AWG 18
4 X AWG 16
4 X AWG 14
4 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6
4 X AWG 4
4 X AWG 2
4 X AWG 1

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

8,4
10,0
11,0
12,6
14,5
18,5
21,0
25,8
30,5
36,0

100
152
180
295
410
640
925
1420
1905
2690

57,0
84,0
128,0
201,0
285,0
457,0
729,0
1107,0
1533,0
2202,0

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

119

CC-Servoflex PUR-C-583
Low capacitance superflexible halogen-free single core cable 0,6/1kV, shielded
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Servoflex-C-583 1G4/AWG12 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
CC-Servoflex single core PUR-C-583 shielded,
UL/CSA and DESINA conforming with low
capacitance is designed to connect electronically
controlled servo and DNC-motors and frequency
converters. It is used in power supply chains,
automatic handling equipment and robots. It can be
used in- and outdoors and where aggressive and
mineral oils occur. A special cable structure and high
quality materials ensure a long service life of
CC-Schleppflex PUR-C-583. Due to the overall
copper shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures a
disturbance free operation of servo and DNC-motors.
The polyurethane outer sheath is highly cut and notch
resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, black
polypropylen (PP) core insulation, tinned copper
shield, fleece. PUR outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive and resistant to hydrolysis and
microbes. Colour DESINA-orange (RAL 2003).

120

Rated voltage:

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 200 MOhm X km

Temperature range:

flexible installation:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

583 0801 00
583 0601 00
583 0401 00
583 0201 00
583 01001 00
583 02001 00
583 03001 00
583 04001 00
583 25001 00
583 35001 00
583 45001 00
583 50001 00

No. of cores

No. of cores

+
crosssection

1 X 10
1 X 16
1 X 25
1 X 35
1 X 50
1 X 70
1 X 95
1 X 120
1 X 150
1 X 185
1 X 240
1 X 300

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

AWG 8
AWG 6
AWG 4
AWG 2
AWG 1/0
AWG 2/0
AWG 3/0
AWG 4/0
AWG250
AWG 350
AWG 450
AWG 500

127
187
258
402
553
776
1.028
1.282
1.572
1.941
2.535
3.129

9,0
10,4
12,0
14,0
15,8
17,4
20,2
23,4
26,4
29,9
34,3
36,8

170
240
353
481
631
853
1.146
1.431
1.950
2.600
3.380
4.100

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

121

CC-Servoflex PUR-C-583
Low capacitance superflexible halogen-free cable 0,6/1kV, shielded
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Servoflex-C-583 4G4 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

CC-Servoflex PUR-C-583 shielded, UL/CSA and


DESINA conforming with low capacitance is
designed to connect electronically controlled servo
and DNC-motors and frequency converters. It is used
in power supply chains, automatic handling
equipment and robots. It can be used in- and outdoors
and where aggressive and mineral oils occur.
A special cable structure and high
quality materials ensure a long service life of
CC-Schleppflex PUR-C-583. Due to the overall
copper shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures a
disturbance free operation of servo and DNC-motors.
The polyurethane outer sheath is highly cut and notch
resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, polypropylen
(PP) core insulation, cores are black with
consecutive white numbering and green/yellow
protective conductor, tinned copper shield.
PUR-based outer sheath , flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1), non-adhesive
and resistant to hydrolysis and microbes.
Colour DESINA-orange (RAL 2003).

122

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operation capacity at 800 Hz:

core/core approx. 70 nF/km


core/shield approx. 110 nF/km

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible installation:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

583 180 408


583 160 408
583 140 408
583 120 408
583 100 408
583 080 408
583 060 408
583 040 408
583 020 408
583 010 408

No. of cores

No. of cores

+
crosssection

4 G 1
4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

4 X AWG 18
4 X AWG 16
4 X AWG 14
4 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6
4 X AWG 4
4 X AWG 2
4 X AWG 1

57
84
128
201
285
457
729
1107
1533
2202

8,4
9,6
10,8
13,1
14,1
17,8
24,5
28,7
34,0
36,0

100
152
180
295
410
640
925
1420
1905
2690

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

123

CC-Schleppflex PUR-588
Low capacitance, high flexible halogen-free single core cable 0,6/1kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-588 1G4/AWG12 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

DIN VDE/IEC:
UL/CSA:

600/1000 V
100 V

Test voltage:
4000 V

CC-Schleppflex PUR-588 low capacitance UL/CSA


halogen-free single core, has been developed as
a control cable for use in power supply chains.
The increasing demand in industrial automation
requires cables with narrow bending radius.
CC-Schleppflex meets this requirement due to its
practice-oriented development. A long service life is
achieved by the special structure and
compounds of the cable.

Construction
Superfine strands of bare copper wire,
PP black or green/yellow core insulation.
PUR outer sheath, extensively resistant to oil and
cooling liquid, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).

124

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

fixed installation:
flexible application:

-50C to +80C
-40C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

AWG

+
crosssection

Copper
weight

Outer diameter
approx.

Weight

kg/km

mm

kg/km

588 1201 00
588 1201 99

1X4
1G4

AWG 12
AWG 12

37
37

6,4
6,4

66
66

588 1001 00
588 1001 99

1X6
1G6

AWG 10
AWG 10

56
56

7,1
7,1

90
90

588 0801 00
588 0801 99

1X10
1G10

AWG 8
AWG 8

93
93

8,4
8,4

138
138

588 0601 00
588 0601 99

1X16
1G16

AWG 6
AWG 6

148
148

9,8
9,8

205
205

588 0401 00
588 0401 99

1X25
1G25

AWG 4
AWG 4

233
233

11,4
11,4

306
306

588 0201 00
588 0201 99

1X35
1G35

AWG 2
AWG 2

326
326

13,4
13,4

431
431

588 01001 00
588 01001 99

1X50
1G50

AWG 1/0
AWG 1/0

478
478

15,2
15,2

572
572

588 02001 00
588 02001 99

1X70
1G70

AWG 2/0
AWG 2/0

645
645

16,6
16,6

783
783

588 03001 00
588 03001 99

1X95
1G95

AWG 3/0
AWG 3/0

880
880

19,2
19,2

1.043
1.043

588 04001 00
588 04001 99

1X120
1G120

AWG 4/0
AWG 4/0

1.200
1.200

22,2
22,2

1.302
1.302

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

125

CC-Servoflex PUR-588
Superflexible low capacitance halogen-free motor-supply cable 0,6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-588 4G4 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

CC-Servoflex PUR-588 low capacitance, UL/CSA


and DESINA conforming is designed to connect
servo and DNC-motors. It is used as a supply cable in
power supply chains, automatic handling equipment
and robots. It can be used in- and outdoors and in
areas where agressive and mineral oils or high
mechanical stress occur. A special cable structure and
high quality materials ensure a long service life.
The polyurethane outer sheath is cut and notch
resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, double
sheathed polyester core insulation, cores are black
with consecutive white numbering and green/yellow
protective conductor. PUR-based outer sheath is
UV-resistant, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1),
non-adhesive, and resistant to hydrolysis and
microbes. Colour DESINA-black (RAL 9005).

126

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

Test voltage:
4000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C to +80C
-50C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 20234
CSA: AWM I A/B, II A/BFT1

ConCab kabel connects the world

Part-No.

588 160 400


588 140 400
588 120 400
588 100 400
588 080 400
588 060 400
588 040 400
588 020 400
588 010 400

No. of cores

No. of cores

+
crosssection

4 G 1,5
4 G 2,5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

4 X AWG 16
4 X AWG 14
4 X AWG 12
4 X AWG 10
4 X AWG 8
4 X AWG 6
4 X AWG 4
4 X AWG 2
4 X AWG 1

58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0

8,5
10,2
11,6
13,2
16,5
19,2
24,1
28,0
35,5

121
209
306
451
744
1210
1505
2086
2923

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

127

CC-Servo PVC-573
Motor-supply cable 0,6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servo-573 4G16+2(21,0) E172073 CUS STYLE 20886 0,6/1kV 80C

Technical data
Rated voltage:
Power cores:

DIN VDE/IEC:
UL/CSA:

CC-Servo PVC-573 is used for electronically


controlled servo-motors as a power and feedback
cable. A special cable structure and high quality
materials ensure a long service life.
The CC-Servo PVC-573 combines power cores and
shielded control cores and can be used for occasional
flexible applications.

Construction
Power cores 0,75 mm2 - 35 mm2:
Fine strands of bare copper wires, PVC core
insulation, cores are black with consecutive white
numbering and green/yellow protective conductor.
Control cores 0,34 mm2 - 1,5 mm2:
Fine strands of bare copper wires, polyester (TPE)
core insulation, cores are black with consecutive
white numbering, twisted in pairs, pairs with
aluminium foil, tinned drain wire, tinned copper
shield. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL7001)
or UL/CSA orange (RAL 2003).

128

DIN VDE/IEC:
UL/CSA:

600/1000 V
1000 V

control cores:
300/500V
1000 V

Test voltage:

power cores: core/core 4000 V


control cores: core/core 1000 V
core/shield 750 V

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

ConCab kabel connects the world

-30C to +80C
-5C to +70C

Bending radius:

15 X cable diameter

Approvals:

acc. to DIN VDE 0281


cUL: Style 20886

Part-No.

No. of cores
+
cross-section

573 407 03 50
573 415 07 50
573 425 07 50
573 440 07 50
573 460 07 50
573 410 07 50
573 416 10 50
573 425 15 50
573 435 15 50

4 G 0,75
4 G 1,5
4 G 2,5
4G4
4G6
4 G 10
4 G 16
4 G 25
4 G 35

+ 2 X (2 X 0,34)(St)C-Y
+ 2 X (2 X 0,75)(St)C-Y
+ 2 X (2 X 0,75)(St)C-Y
+ (2 X 0,75) StC + (2 X 1,0)(St)C-Y
+ (2 X 0,75) StC + (2 X 1,0)(St)C-Y
+ (2 X 0,75) StC + (2 X 1,0)(St)C-Y
+ 2 X (2 X 1,0)(St)C-Y
+ 2 X (2 X 1,5)(St)C-Y
+ 2 X (2 X 1,5)(St)C-Y

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

74,5
143,1
152,0
254,0
321,4
468,6
692,3
1048,8
1509,0

10,6
12,7
14,9
16,6
18,7
22,4
25,9
29,5
33,2

126
194
318
414
551
822
1127
1632
2058

ConCab kabel Mainhardt Servo -573 0,6/1kV

ConCab kabel Mainhardt Pur C-181

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

129

CC-Servo PVC-C-577
Motor-supply cable 0,6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servo-CY-577 4G2,5 E172073 CUS STYLE 20886 1000V 80C DESINA

Technical data
Rated voltage:
power cores:

DIN VDE/IEC:
UL/CSA:
CC-Servo PVC-CY-577 shielded is used for
electronically controlled servo-motors as a power and
feedback cable. A special cable structure and high quality
materials ensure a long service life. Due to the overall
copper shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures
a disturbance-free operation of servo-motors.
The CC-Servo PVC-CY-577 combines power cores and
shielded control cores and can be used for occasional
flexible application.

Construction
Power cores 0,75 mm2 - 35 mm2:
Fine strands of bare copper wires, PVC core
insulation, cores are black with consecutive white
numbering and green/yellow protective conductor.
Control cores 0,34 mm2 - 1,5 mm2:
Fine strands of bare copper wires, polyester (TPE) core
insulation, cores are black with consecutive white
numbering, twisted in pairs, pairs with
aluminium foil, tinned drain wire, tinned copper shield,
tinned copper shield. PVC outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001) or
DESINA-orange (RAL 2003).

130

600/1000 V
1000 V

Control cores:

DIN VDE/IEC:
UL/CSA:

300/500V
1000 V

Test voltage:

Power cores: core/core 4000 V


core/shield 750 V
control cores: core/core 1000 V
core/shield 750 V

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

-30C to +80C
-5C to +70C

Bending radius:

20 X cable diameter

Approvals:

acc. to DIN VDE 0281


UL: Style 20886, VW1 AWMIIA/BFT1

ConCab kabel connects the world

Part-No.

Outer Copper Outer Weight


sheath weight diameter
approx.
colour
ca. mm
kg/km
kg/km

No. of cores
+
cross-section

577 4007 2203 50


577 4015 2207 50
577 4025 2207 50
577 4040 207 210 50
577 4060 207 210 50
577 4100 207 210 50
577 4160 2210 50
577 4250 2215 50
577 4350 2215 50

[4 G 0,75
[4 G 1,5
[4 G 2,5
[4 G 4
[4 G 6
[4 G 10
[4 G 16
[4 G 25
[4 G 35

+ 2 X (2 X 0,34)(St)C]CY
+ 2 X (2 X 0,75)(St)C]CY
+ 2 X (2 X 0,75)(St)C]CY
+ (2 X 0,75)(St)C + (2 X 1,0) (St)C]CY
+ (2 X 0,75)(St)C + (2 X 1,0) (St)C]CY
+ (2 X 0,75)(St)C + (2 X 1,0) (St)C]CY
+ 2 X (2 X 1,0)(St)C]CY
+ 2 X (2 X 1,5)(St)C]CY
+ 2 X (2 X 1,5)(St)C]CY

grey
grey
grey
grey
grey
grey
grey
grey

99,0
164,0
232,0
296,0
376,0
546,0
776,0
1217,0
1654,0

11,5
13,2
15,6
17,3
19,6
23,0
24,6
29,0
34,2

171
322
394
492
621
842
1186
1704
2116

577 4015 215


577 4025 215
577 4040 215
577 4060 215
577 4100 215
577 4160 215
577 4250 215
577 4350 215

[4 G 1,5
[4 G 2,5
[4 G 4
[4 G 6
[4 G 10
[4 G 16
[4 G 25
[4 G 35

+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY
+ (2 X 1,5)]CY

orange
orange
orange
orange
orange
orange
orange
orange

143,0
185,0
267,0
347,0
524,0
767,0
1136,0
1536,0

13,4
14,2
15,4
17,0
21,8
25,6
29,7
32,2

242
380
478
607
828
1116
1633
2087

577 4007 2203 08


577 4010 2207 08
577 4015 2207 08
577 4025 2210 08
577 4040 210 215 08
577 4060 210 215 08
577 4100 210 215 08
577 4160 210 215 08
577 4250 2215 08
577 4350 2215 08
577 4500 2225 08

[4 G 0,75/AWG 19
[4 G 1,0/AWG 18
[4 G 1,5/AWG 16
[4 G 2,5/AWG 14
[4 G 4/AWG 12
[4 G 6/AWG 10
[4 G 10/AWG 8
[4 G 16/AWG 6
[4 G 25/AWG 4
[4 G 35/AWG 2
[4 G 50/AWG 1

+ 2 X (2 X 0,34/AWG 22)]CY  and 


+ 2 X (2 X 0,75/AWG 19)]CY  and 
+ 2 X (2 X 0,75/AWG 19)]CY  and 
+ 2 X (2 X 1,0/AWG 18)]CY  and 
+ (2 X 1,0/AWG 18) + (2 X 1,5/AWG 16)]CY
+ (2 X 1,0/AWG 18) + (2 X 1,5/AWG 16)]CY
+ (2 X 1,0/AWG 18) + (2 X 1,5/AWG 16)]CY
+ (2 X 1,0/AWG 18) + (2 X 1,5/AWG 16)]CY
+ 2 X (2 X 1,5/AWG 16)]CY  and 
+ 2 X (2 X 1,5/AWG 16)]CY  and 
+ 2 X (2 X 2,5/AWG 14)]CY  and 

orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange

101,0
131,0
155,0
202,0
310,0
386,0
563,0
813,0
1190,0
1613,0
2258,0

11,7
13,6
14,8
17,8
16,7
19,2
22,2
25,7
30,2
32,6
39,6

171
270
322
394
492
621
842
1186
1704
2116
3778

577 4015 215 08


577 4025 215 08
577 4040 215 08
577 4060 215 08
577 4100 215 08
577 4160 215 08
577 4250 215 08
577 4350 215 08
577 4500 215 08

[4 G 1,5/AWG 16
[4 G 2,5/AWG 14
[4 G 4/AWG 12
[4 G 6/AWG 10
[4 G 10/AWG 8
[4 G 16/AWG6
[4 G 25/AWG 4
[4 G 35/AWG 2
[4 G 50/AWG 1

+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY
+ (2 X 1,5/AWG 16)]CY

orange
orange
orange
orange
orange
orange
orange
orange
orange

143,0
185,0
276,0
347,0
524,0
767,0
1136,0
1564,0
2201,0

13,4
14,2
15,4
17,0
21,8
25,6
28,7
32,2
34,7

242
380
478
607
828
1116
1633
2087
3298

 and 
 and 
 and 
 and 

 and 
 and 
 and 
 and 
 and 
 and 
 and 
 and 
 and 

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

131

CC-Servo Cable for Siemens Systems


Feedback cables for signal transmission systems
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servo-CY-577 4G10 E172073 CUS STYLE 20886 1000V 80C DESINA

Technical data
Rated voltage:
DIN VDE/IEC:
UL/CSA:
CC-Servo Cable designed for Siemens systems,
is used for electronically controlled servo-motors as a
power and feedback cable. A special cable structure
and high quality materials ensure a long service life.
The CC-Servo combines power cores and shielded
signal resp. control cores and can be used
for flexible application.

Construction
Power cores 1,5 mm2 - 240 mm2:
Superfine strands of bare copper wires,
PVC or polyolefine core insulation, cores are black
with white numbering and green/yellow
protective conductor.
Signal- and control cores 0,14 mm2 - 1,5 mm2:
Superfine strands of bare copper wires,
PVC or polyolefine core insulation, cores are black
with white numbering, twisted in pairs, pairs with
aluminium foil, tinned copper shield. Power cores
and signal resp. control cores twisted. PVC outer
sheath, oil resistant (acc. to DIN VDE 0472 part 803),
flame retardant and self-extinguishing
(acc. to DIN VDE 0482 Teil 265-2-1
resp. EN 50265-2-1 and IEC 60332-1-2).
Colours DESINA orange (RAL 2003) resp.
DESINA green (RAL 6018).

132

DIN VDE/IEC:
UL/CSA:
DIN VDE/IEC:
UL/CSA:

Power cores:
600/1000 V
1000 V
Control cores:
250 V
1000 V
Signal cores:
250 V
300 V

Test voltage:

power cores: core/core 4000 V


control cores: core/core 2000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 5 resp. 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:

flexible application:
fixed installation:

0C up to +60C
-20C up to +80C

flexible application:

12 X cable diameter

Bending radius:

Norms:

acc. to DIN VDE 0250


UL: Style 2502, 2464, 20886
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

Siemens
Reference-No.

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

6FX5008-1BD21
6FX5008-1BD41

79,0
60,0

9,9
9,0

145
126

6FX5008-1BD51

84,1

10,3

148

6FX5008-1BB11
6FX5008-1BB21
6FX5008-1BB31
6FX5008-1BB41
6FX5008-1BB51
6FX5008-1BB61
6FX5008-1BB25
6FX5008-1BB35
6FX5008-1BB50
6FX5008-1BB70
6FX5008-1BB95
6FX5008-1BB12

94,7
143,8
207,6
311,2
483,6
739,0
1120,0
1544,0
2128,6
2950,0
4080,0
5070,0

10,1
11,3
13,0
15,2
19,7
25,8
28,3
32,2
41,0
45,3
49,7
54,0

215
290
390
560
840
1280
1730
2305
3305
4425
6120
7605

6FX5008-1BA11
6FX5008-1BA21
6FX5008-1BA31
6FX5008-1BA41
6FX5008-1BA51
6FX5008-1BA61
6FX5008-1BA25
6FX5008-1BA35
6FX5008-1BA50

143,0
185,0
267,0
347,0
524,0
727,0
1136,0
1536,0
2184,0

13,4
14,2
15,4
17,0
21,8
25,6
29,7
32,2
34,7

242
380
478
607
828
1116
1633
2087
3298

+
cross-section/AWG

Feedback- sensor cable green


251 4203 405 10
252 3201 401 205 10
142 3201 401 10

[4 X 2 X 0,38/AWG 22 + 4 X 0,5/AWG 20]


[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 2 X AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26
+ 4 X AWG 24 + 2 X AWG 20]
Motor cable orange

585 1604 08
585 1404 08
585 1204 08
585 1004 08
585 0804 08
585 0604 08
585 0404 08
585 0204 08
585 0104 08
585 02004 08
585 03004 08
585 04004 08

[4 G 1,5/AWG 16]
[4 G 2,5/AWG 14]
[4 G 4/AWG 12]
[4 G 6/AWG 10]
[4 G 10/AWG 8]
[4 G 16/AWG 6]
[4 G 25/AWG 4]
[4 G 35/AWG 2]
[4 G 50/AWG 1]
[4 G 70/AWG 2/0]
[4 G 95/AWG 3/0]
[4 G 120/AWG 4/0]
Servo cable orange

577 4015 215 08


577 4025 215 08
577 4040 215 08
577 4060 215 08
577 4100 215 08
577 4160 215 08
577 4250 215 08
577 4350 215 08
577 4500 215 08

[4 G 1,5/AWG 16
[4 G 2,5/AWG 14
[4 G 4/AWG 12
[4 G 6/AWG 10
[4 G 10/AWG 8
[4 G 16/AWG 6
[4 G 25/AWG 4
[4 G 35/AWG 2
[4 G 50/AWG 1

+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]
+ (2 X 1,5/AWG 16)]

6FX5008 is a registered trade mark of Siemens AG

ConCab kabel connects the world

133

CC-Cable PUR-C for Siemens Systems


Halogen-free feedback cable for signal transmission systems
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-C-581 4G6 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

Power cores:
600/1000 V
1000 V
Control cores:
DIN VDE/IEC:
250 V
UL/CSA:
1000 V
Signal cores:
DIN VDE/IEC:
250 V
UL/CSA:
300 V

DIN VDE/IEC:
UL/CSA:

CC-Servo Cable PUR-C designed for Siemens


systems, is used for electronically controlled
servo-motors as a power and feedback cable.
A special cable structure and high quality materials
ensure a long service life. The CC-Servo combines
power cores and shielded signal resp. control cores
and can be used for flexible application.

power cores: core/core 4000 V


control cores: core/core 2000 V

Construction

Conductor stranding:

Power cores 1,5 mm2 - 50 mm2:


Superfine strands of bare copper wires, polyester
(TPE) or polyolefine core insulation, cores are black
with white numbering and green/yellow protective
conductor.
Signal- and control cores 0,14 mm2 - 1,5 mm2:
Superfine strands of bare copper wires, polyester
(TPE) or polyolefine core insulation, cores are black
with white numbering, twisted in pairs, pairs with
aluminium foil, tinned copper shield.
Power cores and signal resp. control cores twisted.
PUR outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482 Teil 265-2-1
resp. EN 50265-2-1 and IEC 60332-1-2).
Colours DESINA orange (RAL 2003)
resp. DESINA green (RAL 6018).

134

Test voltage:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0250


UL: Style 20234, 20236,20233
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores
+

Siemens
Reference-Nr.

Copper Outer Weight


weight diameter
approx.
kg/km

mm

kg/km

6FX8008-1BD11
6FX8008-1BD21
6FX8008-1BD31
6FX8008-1BD41

71,3
81,5
82,0
71,5

8,6
8,6
9,7
9,0

125
203
105
126

6FX8008-1BD51

84,1

10,3

148

6FX8008-1BD61
6FX8008-1BD71
6FX8008-1BD81

32,4
18,6
59,0

6,5
5,6
7,1

56
44
132

6FX8008-1BB11
6FX8008-1BB21
6FX8008-1BB31
6FX8008-1BB41
6FX8008-1BB51
6FX8008-1BB61

84,0
128,0
201,0
285,0
457,0
729,0

10,0
11,0
12,6
14,8
18,5
21,0

152
180
295
410
640
925

6FX8008-1BA11
6FX8008-1BA21
6FX8008-1BA31
6FX8008-1BA41
6FX8008-1BA51
6FX8008-1BA61
6FX8008-1BA25
6FX8008-1BA35
6FX8008-1BA50

154,0
266,0
336,0
419,0
595,0
843,0
1203,0
1663,0
2530,0

12,0
12,8
14,4
15,9
18,0
21,8
26,7
30,8
34,7

231
287
375
459
735
1118
1447
1916
2845

cross-section/AWG

Feedback-/ Signal cable green


181 8201 8 10
181 4203 405 10
132 3201 205 10
182 3201 401 205 10
142 3201 401 10
181 4201 8 10
181 2201 8 10
181 1202 3 10

[8 X 2 X 0,18/AWG 25]
[4 X 2 X 0,38/AWG 21 + 4 X 0,5/AWG 20]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)
[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 2 X AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 4 X AWG 24 + 2 X AWG 20]
[4 X 2 X 0,18/AWG 25]
[2 X 2 X 0,18/AWG 25]
[12 X 0,23/AWG 24]
Motor cable orange

581 1604 08
581 1404 08
581 1204 08
581 1004 08
581 0804 08
581 0604 08

[4 G 1,5/AWG 16]
[4 G 2,5/AWG 14]
[4 G 4/AWG 12]
[4 G 6/AWG 10]
[4 G 10/AWG 8]
[4 G 16/AWG 6]
Servo cable orange

582 4015 215 08


582 4025 215 08
582 4040 215 08
582 4060 215 08
582 4100 215 08
582 4160 215 08
582 4250 215 08
582 4350 215 08
582 4500 215 08

[4 G 1,5/AWG 16 + (2 X 1,5/AWG 16)]


[4 G 2,5/AWG 14 + (2 X 1,5/AWG 16)]
[4 G 4,0/AWG 12 + (2 X 1,5/AWG 16)]
[4 G 6,0/AWG 10 + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + (2 X 1,5/AWG 16)]
[4 G 35/AWG 2 + (2 X 1,5/AWG 16)]
[4 G 50/AWG 1 + (2 X 1,5/AWG 16)]

6FX8008 is a registered trade mark of Siemens AG

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

135

CC-Cable PUR-C for Siemens Systems


Halogen-free low capacitance feedback cable for signal transmission systems
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-C-581 4G6 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:
DIN VDE/IEC:
UL/CSA:
DIN VDE/IEC:
UL/CSA:
CC-Servo Cable PUR-C designed for Siemens
systems, is used for electronically controlled
servo-motors as a power and feedback cable.
A special cable structure and high quality materials
ensure a long service life. The CC-Servo combines
power cores and shielded signal resp. control cores
and can be used for flexible application.

Construction
Power cores 1,5 mm2 - 50 mm2:
Superfine strands of bare copper wires, polyolefine
core insulation, cores are black with white numbering
and green/yellow protective conductor
Signal- and control cores 0,14 mm2 - 1,5 mm2:
Superfine strands of bare copper wires, polyolefine
core insulation, cores are black with white
numbering, twisted in pairs, pairs with aluminium
foil, tinned copper shield. Power cores and signal
resp. control cores twisted. PUR outer sheath, flame
retardant and self- extinguishing (acc. to DIN VDE
0482 Teil 265-2-1 resp. EN 50265-2-1
and IEC 60332-1-2).
Colours DESINA orange (RAL 2003)
resp. DESINA green (RAL 6018).

136

DIN VDE/IEC:
UL/CSA:

Power cores:
600/1000 V
1000 V
Control cores:
250 V
1000 V
Signal cores:
250 V
300 V

Test voltage:

power cores: core/core 4000 V


control cores: core/core 2000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0250


UL: Style 20234, 20236,20233
CSA:AMW IA/B, IIA/B FT1

ConCab kabel connects the world

Part-No.

No. of cores
+

Siemens
Reference-Nr.

Copper Outer Weight


weight diameter
approx.
kg/km

mm

kg/km

6FX8008-1BD31
6FX8008-1BD41

71,3
81,5
28,0
82,0
71,5

8,6
8,6
7,0
9,7
9,0

125
203
60
105
126

6FX8008-1BD51

84,1

10,3

148

6FX8008-1BD61
6FX8008-1BD71
6FX8008-1BD81

32,4
18,7
59,0

6,5
5,6
7,1

56
38
132

6FX8008-1BB11
6FX8008-1BB21
6FX8008-1BB31
6FX8008-1BB41
6FX8008-1BB51
6FX8008-1BB61

84,0
128,0
201,0
285,0
457,0
729,0

11,1
11,6
13,1
15,4
19,2
24,5

152
180
295
410
640
925

6FX8008-1BA11 143,0
6FX8008-1BA21 183,0
6FX8008-1BA31 251,0
6FX8008-1BA41 334,0
6FX8008-1BA51 522,0
6FX8008-1BA61 780,0
6FX8008-1BA25 1160,0
6FX8008-1BA35 1567,0
6FX8008-1BA50 2186,0

11,8
12,4
14,4
16,1
18,2
21,8
26,7
30,8
34,7

cross-section/AWG

Feedback-/ Signal cable low capacitance green


281 8201 8 10
281 4203 405 10
281 2201 203 10
232 3201 205 10
282 3201 401 205 10
242 3201 401 10
281 4201 8 10
281 2201 8 10
281 1202 3 10

[8 X 2 X 0,18/AWG 25]
[4 X 2 X 0,38/AWG 21 + 4 X 0,5/AWG 20]
[2 X 2 X 0,15/AWG 26 + 2 X 0,38/AWG 21]
[3 X (2 X 0,14/AWG 26) + 2 X (0,5/AWG 20)
[3 X (2 X 0,14) + 4 X 0,14 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 2 X AWG 20]
[3 X (2 X 0,14) + 4 X 0,14 + 4 X 0,23 + 2 X 0,5]
[3 X (2 X AWG 26) + 4 X AWG 26 + 4 X AWG 24 + 2 X AWG 20]
[4 X 2 X 0,18/AWG 25]
[2 X 2 X 0,18/AWG 25]
[12 X 0,23/AWG 24]

6FX8008-1BD11
6FX8008-1BD21

Motor cable, low capacitance, orange


583 1604 08
583 1404 08
583 1204 08
583 1004 08
583 0804 08
583 0604 08

[4 G 1,5/AWG 16]
[4 G 2,5/AWG 14]
[4 G 4/AWG 12]
[4 G 6/AWG 10]
[4 G 10/AWG 8]
[4 G 16/AWG 6]
Servo cable orange low capacitance, orange

584 4015 215 08


584 4025 215 08
584 4040 215 08
584 4060 215 08
584 4100 215 08
584 4160 215 08
584 4250 215 08
584 4350 215 08
584 4500 215 08

[4 G 1,5/AWG 16 + (2 X 1,5/AWG 16)]


[4 G 2,5/AWG 14 + (2 X 1,5/AWG 16)]
[4 G 4,0/AWG 12 + (2 X 1,5/AWG 16)]
[4 G 6,0/AWG 10 + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + (2 X 1,5/AWG 16)]
[4 G 35/AWG 2 + (2 X 1,5/AWG 16)]
[4 G 50/AWG 1 + (2 X 1,5/AWG 16)]

212
255
347
459
695
987
1485
1970
2795

6FX8008 is a registered trade mark of Siemens AG

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

137

CC-Cable PUR-C for INDRAMAT Systems


Halogen-free feedback cable for signal transmission systems
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 181 2x2 x0,25+2x0,5 E172073 cus AWM STYLE 20233 300V 80C DESINA

Technical data
Rated voltage:

Power cores:
600/1000 V
1000 V
Control cores:
DIN VDE/IEC:
250 V
UL/CSA:
1000 V
DIN VDE/IEC:
UL/CSA:

CC-Servo Cable PUR-C designed for INDRAMAT


systems, is used for electronically controlled
servo-motors as a power and feedback cable.
A special cable structure and high quality materials
ensure a long service life. The CC-Servo combines
power cores and shielded signal resp. control cores
and can be used for flexible application.

Construction
Power cores 0,75 mm2 - 50 mm2:
Superfine strands of bare copper wires, polyester
(TPE) or polyolefine core insulation, cores are black
with white numbering and green/yellow
protective conductor.
Signal- und control cores 0,14 mm2 - 2,5 mm2:
Superfine strands of bare copper wires, polyester
(TPE) or polyolefine core insulation, cores are black
with white numbering, twisted in pairs, pairs with
aluminium foil, tinned copper shield, special foil
wrapping. Power cores and signal resp. control cores
twisted together. PUR outer sheath flame retardant
and self-extinguishing (acc. to DIN VDE 0482 Teil
265-2-1 resp. EN 50265-2-1 and IEC 60332-1-2).
Colours DESINA orange (RAL 2003)
resp. DESINA green (RAL 6018).

138

Test voltage:

power cores: core/core 4000 V


control cores: core/core 2000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C bis +80C


-50C bis +80C

Bending radius:

7,5 X cable diameter

Norms:

acc. to DIN VDE 0250


UL: Style 20233, 20234, 0236
CSA: AWM I A/B, II A/B, FT1

ConCab kabel connects the world

Part-No.

No. of cores
+

Indramat
Reference-No.

cross-section/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

182 2202 205 10


181 2202 205 10
181 4202 205 10
181 4202 210 10
181 905 10
181 410 4201 401 10

Encoder-/ feedback- and resolver cable green


INK-0750
[2 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
INK-0234
[2 X (2 X 0,25/AWG 24)StC + 2 X 0,5/AWG 20]
INK-0448
[4 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
INK-0209
[4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
INK-0208
[9 X 0,5/AWG 20]
INK-0532
[4 X 1,0 + 4 X 2 X 0,14 + 4 X 0,14]
[4 X AWG 18 + 4 X 2 X AWG 26 + 4 X AWG 26]

35,0
46,0
63,0
72,0
73,0
86,8

7,6
8,7
8,8
8,8
8,8
9,7

92
90
124
134
125
140

282 2202 205 10


281 2202 205 10
281 4202 205 10
281 4202 210 10
281 905 10
281 410 4201 401 10

Encoder-/ feedback- and resolver cable low capacitance green


[2 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
INK-0750
[2 X (2 X 0,25/AWG 24)StC + 2 X 0,5/AWG 20]
INK-0234
[4 X 2 X 0,25/AWG 24 + 2 X 0,5/AWG 20]
INK-0448
[4 X 2 X 0,25/AWG 24 + 2 X 1,0/AWG 18]
INK-0209
[9 X 0,5/AWG 20]
INK-0208
[4 X 1,0 + 4 X 2 X 0,14 + 4 X 0,14]
INK-0532
[4 X AWG 18 + 4 X 2 X AWG 26 + 4 X AWG 26]

35,0
46,0
63,0
72,0
62,3
86,8

7,6
8,7
8,8
8,8
8,8
9,7

92
90
124
134
125
140

INK-0670
INK-0653
INK-0650
INK-0602
INK-0603
INK-0604
INK-0605
INK-0606
INK-0607
INK-0667
INK-0668

73,0
156,0
184,0
296,0
366,0
449,0
625,0
873,0
1233,0
1723,0
2597,0

10,0
11,5
12,1
15,1
16,0
18,0
22,6
25,2
28,0
30,5
37,0

128
284
370
441
565
652
885
1284
1782
2570
3316

INK-0670
INK-0653
INK-0650
INK-0602
INK-0603
INK-0604
INK-0605
INK-0606
INK-0607
INK-0667
INK-0668

82,4
127,0
153,0
237,0
296,0
377,0
569,0
831,0
1209,0
1620,0
2270,0

10,0
11,5
12,7
15,1
16,0
18,0
20,8
23,6
28,0
30,5
37,0

128
210
241
302
439
587
788
1077
1554
2052
2887

582 4007 205 08


582 4010 2207 08
582 4015 2207 08
582 4025 2215 08
582 4040 2215 08
582 4060 2215 08
582 4100 2215 08
582 4160 2215 08
582 4250 2215 08
582 4350 2215 08
582 4500 2225 08

Servo cable orange


[4 G 0,75/AWG 19 + 2 X 0,5/AWG 20]
[4 G 1,0/AWG 18 + 2 X (2 X 0,75/AWG 19)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,75/AWG 19)]
[4 G 2,5/AWG 14 + 2 X (2 X 1,5/AWG 16)]
[4 G 4/AWG 12
+ 2 X (2 X 1,5/AWG 16)]
[4 G 6/AWG 10
+ 2 X (2 X 1,5/AWG 16)]
[4 G 10/AWG 8
+ 2 X (2 X 1,5/AWG 16)]
[4 G 16/AWG 6
+ 2 X (2 X 1,5/AWG 16)]
[4 G 25/AWG 4
+ 2 X (2 X 1,5/AWG 16)]
[4 G 35/AWG 2
+ 2 X (2 X 1,5/AWG 16)]
[4 G 50/AWG 1
+ 2 X (2 X 2,5/AWG 14)]

584 4007 205 08


584 4010 2207 08
584 4015 2207 08
584 4025 2215 08
584 4040 2215 08
584 4060 2215 08
584 4100 2215 08
584 4160 2215 08
584 4250 2215 08
584 4350 2215 08
584 4500 2225 08

[4 G 0,75/AWG 19 + 2 X 0,5/AWG 20]


[4 G 1,0/AWG 18 + 2 X (2 X 0,75/AWG 19)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,75/AWG 19)]
[4 G 2,5/AWG 14 + 2 X (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + (2 X 1,0/AWG 18 + (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + (2 X 1,0/AWG 18 + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1,0/AWG 18 + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6
+ 2 X (2 X 1,5/AWG 16)]
[4 G 25/AWG 4
+ 2 X (2 X 1,5/AWG 16)]
[4 G 35/AWG 2
+ 2 X (2 X 1,5/AWG 16)]
[4 G 50/AWG 1
+ 2 X (2 X 2,5/AWG 14)]

Servo cable low capacitance orange

INK is a registered trade mark of Bosch Rexroth AG

For installation instruction please see page 548.

ConCab kabel connects the world

139

CC-Servoflex PUR-579
Superflexible motor-supply cable 0,6/1 kV
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-579 4G2,5+221,5 0,6/1kV

CC-Servoflex PUR-579 is designed for electronically


controlled servo motors and as a power and feedback
cable for power supply chains, automatic handling
equipment and robots. It can be used in- and outdoors
and where agressive and mineral oils occur. A special
cable structure and high quality materials ensure
a long service life. The PUR outer sheath is highly
cut and notch resistant and non-abrasive.
CC-Servoflex PUR-579 combines power cores and
shielded control cores.

Construction
Power cores 0,75 mm2 - 35 mm2:
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering 1-3 and
green/yellow protective conductor.

Technical data
Rated voltage:

power cores:
control cores:
power cores:
control cores:

Test voltage:

core/core 4000 V
core/core 1000 V
core/shield 750 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Control cores 0,34 mm2 - 1,5 mm2:


Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering, cores twisted in pairs,
pairs with aluminium foil, tinned drain wire, tinned
copper shield. Power and paired control cores
twisted. PUR-based outer sheath, flame retardant and
self-extinguising (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour orange (RAL 2003).

140

600/1000 V
300/500 V

ConCab kabel connects the world

Insulation resistance:

min. 100 MOhm X km

Temperature range:
-30C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

cross-section

kg/km

mm

kg/km

579 4007 2203


579 4015 2205
579 4015 2207
579 4025 2215
579 4040 2215
579 4060 2215
579 4100 2215
579 4160 2215
579 4250 2215
579 4350 2215

4 G 0,75
4 G 1,5
4 G 1,5
4 G 2,5
4G4
4G6
4 G 10
4 G 16
4 G 25
4 G 35

+ 2 X (2 X 0,34)
+ 2 X (2 X 0,50)
+ 2 X (2 X 0,75)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)
+ 2 X (2 X 1,5)

94,0
104,0
110,0
226,0
284,0
341,0
487,0
718,0
1063,0
1645,0

9,7
11,0
11,4
17,3
18,6
18,8
24,0
26,5
30,0
32,2

125
320
350
416
530
616
840
1230
1740
2410

579 4015 215


579 4025 215
579 4040 215
579 4060 215
579 4100 215
579 4160 215
579 4250 215
579 4350 215

4 G 1,5
4 G 2,5
4G4
4G6
4 G 10
4 G 16
4 G 25
4 G 35

+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)
+ (2 X 1,5)

118,0
166,0
234,0
318,0
513,0
797,0
1268,0
1683,0

10,9
11,7
13,3
16,3
19,2
21,9
25,8
30,4

350
386
402
586
810
1198
1705
2374

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

141

CC-Servoflex PUR-C-582
Halogen-free superflexible motor cable 0,6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-C-582 4G4+2x(2x1,5) 0,6/1kV DESINA

CC-Servoflex PUR-C-582 shielded and DESINA


conforming is designed for electronically
controlled servo motors and as a power and feedback
cable for power supply chains, automatic handling
equipment and robots. It can be used in- and outdoors
and in areas where agressive and mineral oils occur.
A special cable structure and high quality
materials ensure a long service life. Due to the overall
copper shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures
a disturbance-free operation of servo motors. The
PUR outer sheath is highly cut, notch and abrasion
resistant. The CC-Servoflex PUR-C-582 combines
power cores and shielded paired control cores.

Construction
Power cores 0,75 mm2 - 50 mm2:
Superfine strands of bare copper wires, TPEcore
insulation, cores are black, numbered in white 1-3
and green/yellow protective conductor.
Control cores 0,34 mm2 - 2,5 mm2:
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering, twisted in pairs, pairs
shielded with aluminium foil, tinned drain wire,
tinned copper shield. Power and paired control cores
twisted, tinned copper shield.
PUR-based outer sheath, flame retardant and
self- extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour petrol or DESINA-orange (RAL 2003).

142

Technical data
Rated voltage:

power cores:
control cores:
power cores:

600/1000 V
300/500 V

Test voltage:

core/core
core/shield
control cores:
core/core
core/shield

4000 V
2000 V
2000 V
1000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

ConCab kabel connects the world

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+

Outer
sheath
colour

cross-section

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

582 4007 2203


582 4010 2207
582 4015 2205
582 4015 2207
582 4025 2215
582 4040 2215
582 4040 2207 210
582 4060 2215
582 4100 2215
582 4100 2207 210
582 4160 2210
582 4160 2215
582 4250 2215
582 4350 2215
582 4500 2225

[4 G 0,75
[4 G 1,0
[4 G 1,5
[4 G 1,5
[4 G 2,5
[4 G 4
[4 G 4
[4 G 6
[4 G 10
[4 G 10
[4 G 16
[4 G 16
[4 G 25
[4 G 35
[4 G 50

+ 2 X (2 X 0,34)]
+ 2 X (2 X 0,75)]
+ 2 X (2 X 0,50)]
+ 2 X (2 X 0,75)]
+ 2 X (2 X 1,5)]
+ 2 X (2 X 1,5)]
+ (2 X 0,75) + (2 X 1,0)]
+ 2 X (2 X 1,5)]
+ 2 X (2 X 1,5)]
+ (2 X 0,75) + (2 X 1,0)]
+ 2 X (2 X 1,0)]
+ 2 X (2 X 1,5)]
+ 2 X (2 X 1,5)]
+ 2 X (2 X 1,5)]
+ 2 X (2 X 2,5)]

orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange
orange

114,0
156,0
178,0
184,0
296,0
366,0
331,0
449,0
625,0
595,0
863,0
873,0
1233,0
1723,0
2597,0

11,0
12,0
12,1
12,1
15,1
17,8
17,8
18,0
21,5
23,8
23,2
26,8
29,2
32,4
37,0

171
284
340
370
441
565
545
652
885
865
1220
1284
1782
2570
3316

582 4015 210


582 4025 210
582 4040 210
582 4060 210
582 4100 210
582 4160 210
582 4250 215
582 4350 215
582 4500 215

[4 G 1,5
[4 G 2,5
[4 G 4
[4 G 6
[4 G 10
[4 G 16
[4 G 25
[4 G 35
[4 G 50

+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,5)]
+ (2 X 1,5)]
+ (2 X 1,5)]

petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol
petrol

154,0
266,0
336,0
419,0
595,0
843,0
1203,0
1663,0
2530,0

12,0
12,8
14,4
17,6
20,4
23,4
28,0
32,3
35,3

231
287
375
459
735
1118
1447
1916
2845

582 4015 210 8


582 4025 210 8
582 4040 210 8
582 4060 210 8
582 4100 210 8
582 4160 210 8
582 4250 215 8
582 4350 215 8
582 4500 215 8

[4 G 1,5
[4 G 2,5
[4 G 4
[4 G 6
[4 G 10
[4 G 16
[4 G 25
[4 G 35
[4 G 50

+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,0)]
+ (2 X 1,5)]
+ (2 X 1,5)]
+ (2 X 1,5)]

orange
orange
orange
orange
orange
orange
orange
orange
orange

154,0
266,0
336,0
419,0
595,0
843,0
1203,0
1663,0
2530,0

12,0
12,8
14,4
17,6
20,4
23,4
28,0
32,3
35,3

231
287
375
459
735
1118
1447
1916
2845

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

143

CC-Servoflex PUR-C-582
Halogen-free superflexible cable 0,6/1 kV, shielded
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt Servoflex-C-582 4G2,5+2x2x1,5 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

CC-Servoflex PUR-C-582 shielded UL/CSA and


DESINA conforming is designed for electronically
controlled servo motors and as a supply and feedback
cable for power supply chains, automatic handling
equipment and robots. It can be used in- and outdoors
and in areas where agressive and mineral oils occur.
A special cable structure and high quality
materials ensure a long service life. Due to the overall
copper shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures
a disturbance-free operation of servo motors.
The PUR outer sheath is highly cut, notch and
abrasion resistant. The CC-Servoflex PUR-C-582
combines power cores and shielded paired
control cores.

Construction
Power cores 0,75 mm2 - 50 mm2:
Superfine strands of bare copper wires, TPEcore
insulation, cores are black, numbered in white 1-3
and green/yellow protective conductor.
Control cores 0,34 mm2 - 2,5 mm2:
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering, twisted in pairs, pairs
shielded with aluminium foil, tinned drain wire,
tinned copper shield. Power and paired control cores
twisted, tinned copper shield.
PUR-based outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour DESINA-orange (RAL 2003).

144

Technical data
Rated voltage:

power cores:
600/1000 V
1000 V
control cores:
DIN VDE/IEC:
300/500 V
UL/CSA:
1000 V
DIN VDE/IEC:
UL/CSA:

power cores:
control cores:

Test voltage:

core/core 4000 V
core/shield 2000 V
core/core 2000 V
core/shield 1000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10264, 20234
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

Part-No.

No. of cores
+
cross-section/AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

582 4007 205 08


582 4007 2203 08
582 4010 2207 08
582 4015 2205 08
582 4015 2207 08
582 4025 2215 08
582 4040 2215 08
582 4060 2215 08
582 4100 2215 08
582 4160 2215 08
582 4250 2215 08
582 4350 2215 08
582 4500 2225 08

[4 G 0,75/AWG 19 + 2 X 0,5/AWG 20)]


[4 G 0,75/AWG 19 + 2 X (2 X 0,34/AWG 22)]
[4 G 1,0/AWG 18 + 2 X (2 X 0,75/AWG 19)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,50/AWG 20)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,75/AWG 19)]
[4 G 2,5/AWG 14 + 2 X (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + 2 X (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + 2 X (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + 2 X (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + 2 X (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + 2 X (2 X 1,5/AWG 16)]
[4 G 35/AWG 2 + 2 X (2 X 1,5/AWG 16)]
[4 G 50/AWG 1 + 2 X (2 X 2,5/AWG 14)]

82,4
114,0
156,0
178,0
184,0
296,0
366,0
449,0
579,0
873,0
1233,0
1723,0
2597,0

10,0
11,0
11,5
12,1
12,1
15,1
16,0
18,0
22,6
25,2
28,0
30,5
37,0

128
171
284
340
370
441
565
652
885
1284
1782
2570
3316

582 4015 210 08


582 4015 215 08
582 4025 215 08
582 4040 215 08
582 4060 215 08
582 4100 215 08
582 4160 215 08
582 4250 215 08
582 4350 215 08
582 4500 215 08

[4 G 1,5/AWG 16 + (2 X 1,0/AWG 18)]


[4 G 1,5/AWG 16 + (2 X 1,5/AWG 16)]
[4 G 2,5/AWG 14 + (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + (2 X 1,5/AWG16)]
[4 G 35/AWG 2 + (2 X 1,5/AWG16)]
[4 G 50/AWG 1 + (2 X 1,5/AWG16)]

114,0
154,0
266,0
336,0
419,0
595,0
843,0
1203,0
1663,0
2530,0

11,6
12,0
12,8
14,4
15,9
18,0
21,8
26,7
30,8
34,7

221
231
287
375
459
735
1118
1447
1916
2845

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

145

CC-Servoflex PUR-C-584
Low-capacitance halogen-free superflexible motor cable 0,6/1kV, shielded
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Servoflex-C-582 4G2,5+2x2x1,5 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
CC-Servoflex PUR-C-584 shielded UL/CSA and
DESINA conforming with low capacitance is
designed for electronically controlled servo motors
and as a power and feedback cable for power supply
chains, automatic handling equipment and robots. It
can be used in- and outdoors and in areas where
agressive and mineral oils occur. A special cable
structure and high quality materials ensure a long
service life. Due to the overall copper shield the cable
meets the electromagnetic compatibility (EMC)
requirements and ensures a disturbance-free operation
of servo motors. The PUR outer sheath is highly cut,
notch and abrasion resistant.
The CC-Servoflex PUR-C-584 combines power cores
and shielded paired control cores.

Construction
Power cores 0,75 mm2 - 50 mm2:
Superfine strands of bare copper wires, polyolefin
core insulation, cores are black, numbered in white
1-3 and green/yellow protective conductor.
Control cores 0,34 mm2 - 2,5 mm2:
Superfine strands of bare copper wires, polyester
(TPE) core insulation, cores are black with
consecutive white numbering, twisted in pairs, pairs
shielded with aluminium foil, tinned drain wire,
tinned copper shield. Power and
paired control cores twisted, tinned copper shield.
PUR-based outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour DESINA-orange (RAL 2003).

146

Rated voltage:

power cores:
600/1000 V
1000 V
control cores:
DIN VDE/IEC:
300/500 V
UL/CSA:
1000 V
DIN VDE/IEC:
UL/CSA:

Test voltage:

power cores: core/core 4000 V


core/shield 2000 V
control cores: core/core 2000 V
core/shield 1000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Operating capacity at 800 Hz:

core/core approx. 70 nF/km


core/shield approx. 110 nF/km

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10264, 20234
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

cross-section/AWG

kg/km

ca. mm

kg/km

584 4007 205 08


584 4007 2203 08
584 4010 2207 08
584 4015 205 08
584 4015 2205 08
584 4015 2207 08
584 4025 2215 08
584 4025 210 215 08
584 4040 2215 08
584 4040 210 215 08
584 4060 2215 08
584 4060 210 215 08
584 4100 2215 08
584 4100 210 215 08
584 4160 2215 08
584 4250 2215 08
584 4350 2215 08
584 4500 2225 08

[4 G 0,75/AWG 19 + 2 X 0,5/AWG 20)]


[4 G 0,75/AWG 19 + 2 X (2 X 0,34/AWG 22)]
[4 G 1,0/AWG 18 + 2 X (2 X 0,75/AWG 19)]
[4 G 1,5/AWG 16 + 2 X 0,50/AWG 20)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,50/AWG 20)]
[4 G 1,5/AWG 16 + 2 X (2 X 0,75/AWG 19)]
[4 G 2,5/AWG 14 + 2 X (2 X 1,5/AWG 16)]
[4 G 2,5/AWG 14 + (2 X 1/AWG 18) + (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + 2 X (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + (2 X 1/AWG 18) + (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + 2 X (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + (2 X 1/AWG 18) + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + 2 X (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1/AWG 18) + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + 2 X (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + 2 X (2 X 1,5/AWG 16)]
[4 G 35/AWG 2 + 2 X (2 X 1,5/AWG 16)]
[4 G 50/AWG 1 + 2 X (2 X 2,5/AWG 14)]

82,4
93,2
127,0
111,0
146,0
153,0
237,0
227,0
306,0
296,0
387,0
377,0
579,0
569,0
831,0
1209,0
1620,0
2270,0

10,0
11,2
11,5
11,4
12,1
12,7
15,1
15,1
16,0
16,0
18,0
18,0
20,8
20,8
23,6
28,0
30,5
37,0

128
186
210
190
232
241
302
302
439
439
587
587
788
788
1077
1554
2052
2887

584 4010 210 08


584 4015 210 08
584 4015 215 08
584 4025 215 08
584 4040 215 08
584 4060 215 08
584 4100 215 08
584 4160 215 08
584 4250 215 08
584 4350 215 08
584 4500 215 08

[4 G 1/AWG 18 + (2 X 1/AWG 18)]


[4 G 1,5/AWG 16 + (2 X 1,0/AWG 18)]
[4 G 1,5/AWG 16 + (2 X 1,5/AWG 16)]
[4 G 2,5/AWG 14 + (2 X 1,5/AWG 16)]
[4 G 4/AWG 12 + (2 X 1,5/AWG 16)]
[4 G 6/AWG 10 + (2 X 1,5/AWG 16)]
[4 G 10/AWG 8 + (2 X 1,5/AWG 16)]
[4 G 16/AWG 6 + (2 X 1,5/AWG 16)]
[4 G 25/AWG 4 + (2 X 1,5/AWG 16)]
[4 G 35/AWG 2 + (2 X 1,5/AWG 16)]
[4 G 50/AWG 1 + (2 X 1,5/AWG16)]

110,0
119,0
143,0
183,0
251,0
334,0
522,0
780,0
1160,0
1567,0
2186,0

11,1
11,4
11,8
12,4
14,4
16,1
18,2
21,8
26,7
30,8
34,7

177
205
212
255
347
459
695
987
1485
1970
2795

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

147

CC-Servoflex-Linear PUR-C-592
Halogen-free superflexible motor-supply cable, shielded
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Servoflex-C-592 4x2,5+4x0,5 E172073 CUS AWM STYLE 20234 1000V 80C DESINA

Technical data
Rated voltage:

CC-Servoflex PUR-C-592 shielded UL/CSA and


DESINA conforming is designed for electronically
controlled linear motors and as a power and feedback
cable for power supply chains, automatic handling
equipment and robots. It can be used in- and outdoors
and in areas where agressive and mineral oils occur.
A special cable structure and high quality materials
ensure a long service life. Due to the overall copper
shield the cable meets the electromagnetic
compatibility (EMC) requirements and ensures a
disturbance-free operation of servo motors. The PUR
outer sheath is highly cut, notch and abrasion
resistant. The CC-Servoflex-Linear PUR-C-592 combines power cores and shielded paired control cores.

Construction
Power cores 1,5 mm2 - 25 mm2:
Superfine strands of bare copper wires, TPEcore
insulation, cores are black, numbered in white 1-3
and green/yellow protective conductor.
Control cores 0,5 mm2:
Superfine strands of bare copper wires, TPE core
insulation, cores are red, yellow, black and white.
Cores twisted to quad. Tinned copper shield. Power
and control cores twisted, tinned copper shield. PURbased outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1), nonadhesive, resistant to hydrolysis and microbes.
Colour DESINA-orange (RAL 2003).

148

power cores:
600/1000 V
1000 V
control cores:
DIN VDE/IEC:
300/500 V
UL/CSA:
1000 V
DIN VDE/IEC:
UL/CSA:

Test voltage:

power cores: core/core 4000 V


core/shield 2000 V
control cores: core/core 2000 V
core/shield 1000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

flexible application:
fixed installation:

-40C up to +80C
-50C up to +80C

Bending radius:

10 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281


UL: Style 10264, 20234
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

No. of cores

Part-No.

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

150
190
250
350
550
770
1120

13,7
14,8
16,2
18,4
22,9
26,0
30,5

315
394
526
614
837
1236
1734

+
cross-section/AWG
592 4015 405 08
592 4025 405 08
592 4040 405 08
592 4060 405 08
592 4100 405 08
592 4160 405 08
592 4250 405 08

[4 G 1,5/AWG 16 + (4 X 0,5/AWG 20)]


[4 G 2,5/AWG 14 + (4 X 0,5/AWG 20)]
[4 G 4/AWG 12 + (4 X 0,5/AWG 20)]
[4 G 6/AWG 10 + (4 X 0,5/AWG 20)]
[4 G 10/AWG 8 + (4 X 0,5/AWG 20)]
[4 G 16/AWG 6 + (4 X 0,5/AWG 20)]
[4 G 25/AWG 4 + (4 X 0,5/AWG 20)]

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

149

CC-Robotflex PUR-90
Halogen-free superflexible robotic cable
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Robotflex-90 250,25 CUS STYLE 20940 600V 80C

Technical data
Rated voltage:

DINVDE/IECup to 0,34 mm:


DINVDE/IECup to 0,50 mm:

300 V
300 V

UL/CSA up to 0,14 mm:


UL/CSA up to 1,5 mm:
UL/CSA up to 2,5 mm:

300 V
600 V
1000 V

Test voltage:

CC-Robotflex PUR-90 is designed for robotic


systems, automatic handling equipment and for
machineries with no special movement schedule.
It can be used in- and outdoors. A special cable
construction and high quality components allow the
cable to meet high bending radius and torsion cycles
over a long service life. It can be used in areas where
agressive and mineral oils occur and where the cable
is exposed to high mechanical stress. The PUR outer
sheath is cut and notch resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, polyester
(TPE) core insulation, core colours acc. to
DIN 47100. Cores from 0,5 mm2 are black with
consecutive white numbering. 3 cores and more with
green/yellow protective conductor in the outer layer.
Cores twisted in bundels and laid in layer, special
wrapping over each layer. PUR-based outer sheath,
UV-resistant, non-adhesive, flame retardant and
self-extinguishing (acc. to DINVDE 0482
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
resistant to hydrolysis and microbes.
Colour black (RAL 9005).

150

up to 0,34 mm2:
from 0,50 mm2:

1500 V
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

fixed application:
flexible installation:

-30C to +80C
-50C to +80C

Bending radius:

10 X cable diameter

Torsion angle:

max. 360 per meter

Norms:

acc. to DIN VDE 0245, 0281


UL: up to 0,14mm2 Style 20549
UL: from 0,25mm2 Style 20940
CSA: AWM I A/B, II A/B FT1

ConCab kabel connects the world

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

+
cross-section/ AWG
90 0002 007 00
90 0002 012 00
90 0002 025 00

7 X 0,25/ AWG 24
12 X 0,25/ AWG 24
25 X 0,25/ AWG 24

16,8
28,8
60,0

6,3
8,7
9,8

46
73
144

90 0003 002 00
90 0003 004 00
90 0003 007 00
90 0003 012 00

2 X 0,34/ AWG 22
4 X 0,34/ AWG 22
7 X 0,34/ AWG 22
12 X 0,34/ AWG 22

6,6
15,0
22,8
39,2

4,9
5,5
6,8
9,2

28
40
67
113

90 0005 018 00
90 0005 025 00

18 G 0,50/ AWG 20
25 G 0,50/ AWG 20

86,4
120,0

10,8
12,6

186
254

90 0007 004 00
90 0007 007 00
90 0007 014 00

4 G 0,75/ AWG 19
7 G 0,75/ AWG 19
14 G 0,75/ AWG 19

28,8
50,0
100,8

6,7
7,9
12,5

68
117
214

90 0010 002 00
90 0010 003 00
90 0010 004 00
90 0010 007 00
90 0010 012 00
90 0010 018 00
90 0010 025 00
90 0010 034 00
90 0010 041 00

2 X 1,0/ AWG 18
3 G 1,0/ AWG 18
4 G 1,0/ AWG 18
7 G 1,0/ AWG 18
12 G 1,0/ AWG 18
18 G 1,0/ AWG 18
25 G 1,0/ AWG 18
34 G 1,0/ AWG 18
41 G 1,0/ AWG 18

19,2
29,0
38,4
67,0
115,0
173,0
240,0
326,0
393,0

6,2
6,6
7,3
9,0
12,3
13,0
15,1
18,9
18,4

47
64
78
129
208
286
384
501
600

90 1610 210 00

16 G 1,0/ AWG 18
+ (2 X 1,0/ AWG 18)
23 G 1,0/ AWG 18
+ (2 X 1,0/ AWG 18)

196,0

16,1

375

243,0

17,0

471

90 0015 012 00
90 0015 018 00
90 0015 025 00

12 G 1,5/ AWG 16
18 G 1,5/ AWG 16
25 G 1,5/ AWG 16

173,0
259,0
360,0

14,3
14,7
17,6

288
424
574

90 0025 003 00
90 0025 004 00

3 G 2,5/ AWG 14
4 G 2,5/ AWG 14

72,0
96,0

9,2
10,2

157
189

90 0040 003 00
90 0100 003 00
90 0160 003 00
90 0250 003 00
90 0350 003 00

3 G 4/ AWG 12
3 G 10/ AWG 8
3 G 16/ AWG 6
3 G 25/ AWG 4
3 G 35/ AWG 2

115,2
288,0
460,8
720,0
1008,0

10,9
15,2
18,7
23,6
26,8

224
508
756
1226
1614

90 2310 210 00

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

151

CC-Robotflex PUR-D-91
Halogen-free superflexible robotic cable, shielded
Conforms to EU low-voltage guideline 73/23 EEC

ConCab kabel Mainhardt Robotflex-D-91 18G1,5 CUS STYLE 20940 600V 80C

Technical data
Rated voltage:

CC-Robotflex PUR-C-91 superflexible shielded, is


designed for robotic systems, automatic handling
equipment and for machineries with no special
movement schedule. It can be used in- and outdoors.
A special cable construction and high quality
components allow the cable to meet high bending
radius and torsion cycles over a long service life. It
can be used in areas where agressive and mineral oils
occur and where the cable is exposed to high
mechanical stress. The PUR outer sheath is cut and
notch resistant and non-abrasive.

Construction
Superfine strands of bare copper wires, polyester
(TPE) core insulation, core colours acc.
to DIN 47100. Cores from 0,5 mm are black with
consecutive white numbering. 3 cores and more with
green/yellow protective conductor in the outer layer.
Cores twisted in bundels and laid in layer, special
wrapping over each layer. Spiral shield of tinned
copper wires. PUR-based outer sheath, UV-resistant,
non-adhesive, flame retardant and self-extinguishing
(acc. to DINVDE 0482 part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1), resistant to
hydrolysis and microbes. Colour black (RAL 9005).

152

DIN VDE/IEC up to 0,34 mm:


DIN VDE/IEC up to 0,50 mm:

300 V
300/500 V

UL/CSA 0,14 mm2:


UL/CSA up to 1,5 mm2:
UL/CSA up to 2,5 mm2:

300 V
600 V
1000 V

up to 0,34 mm2:
from 0,50 mm:

Test voltage:

1500 V
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE 029, class 6

Insulation resistance:

min. 100 MOhm X km

Temperature range:

fixed application:
flexible installation:

-30C to +80C
-50C to +80C

Bending radius:

10 X cable diameter

Torsion angle:

max. 360 per meter

Norms:

acc. to DIN VDE 0245, 0281


UL/CSA: 0,14mm2 Style 20549
UL/CSA: from 0,25mm2 Style 20940

ConCab kabel connects the world

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

+
cross-section/AWG
91 0001 012 00
91 0001 018 00

[12 X 0,14/ AWG 26]


[18 X 0,14/ AWG 26]

42,4
52,5

7,0
8,3

92
111

91 0002 012 00
91 0002 018 00
91 0002 025 00

[12 X 0,25/ AWG 24]


[18 X 0,25/ AWG 24]
[25 X 0,25/ AWG 24]

59,6
75,6
97,4

8,5
9,3
11,2

118
157
195

91 0003 004 00

[4 X 0,34/ AWG 22]

22,0

5,9

46

91 0015 012 00
91 0015 012 01
91 0015 018 00

[12 G 1,5/ AWG 16]


[12 X 1,5/ AWG 16]
[18 G 1,5/ AWG 16]

260,0
260,0
380,0

14,6
14,6
15,3

390
390
595

92 0001 003 00

[3 X 2 X 0,14/ AWG 26]

18,0

6,1

51

92 0003 003 00
92 0003 005 00

[3 X 2 X 0,34/ AWG 22]


[5 X 2 X 0,34/ AWG 22]

46,2
65,6

6,4
9,3

81
125

93 6402 101

6 X (4 X 0,21/ AWG 24)


+ 1 X (3 X 0,21/ AWG 24)

98,0

11,3

233

2 X 0,21/ AWG 24 + 2 X 0,14/ AWG 26


+ 4 X (2 X 0,14/ AWG 26)
+ 2 X (2 X 0,21/ AWG 24) + 3 X 0,14/ AWG 26

173,0

8,4

300

93 1417 022 10

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

153

CC-Sensor-Actuator PVC-566
Data cable for decentralized machine installations
Conforms to EU low-voltage guidline 73/23/EEC

ConCab kabel Mainhardt Sensor-Aktor-566 4x0,25

Also available pre-assembled with


sockets and connectors.

Technical data
Rated voltage:
300 V

Test voltage:
1200 V

Conductor stranding:

The Sensor-Actuator cable PVC-566 has been


designed for special installation and control
technology applications. Pre-assembled with sockets
and connectors, it grants high flexibility to make
adjustments, extentions or changes at
automation lines.

Construction
Fine strands of bare copper wire, PVC core
insulation, core colours as described in the table
below, cores twisted in layers. PVC outer sheath,
resistant to oil and cooling liquid, flame retardant
and self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Part-No.

No. of cores

Core colours

+
crosssection

154

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

min. 20 MOhm X km

Temperature range:

fixed installation:
flexible application:

-30C to +80C
-5C to +80C

Bending radius:

15 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812

Copper
Outer
weight diameter
approx.

Weight

kg/km

kg/km

mm

566 0002 003


566 0002 004
566 0002 005

3 X 0,25
4 X 0,25
5 X 0,25

bn, bu, bk
bn, bu, bk, wh
bn, bu, bk, wh, gnye

7,2
9,6
12,0

4,4
4,7
4,8

23
25
32

566 0003 003


566 0003 004
566 0003 005

3 X 0,34
4 X 0,34
5 X 0,34

bn, bu, bk
bn, bu, bk, wh
bn, bu, bk, wh, gnye

9,8
13,1
16,3

4,9
5,2
5,9

29
43
55

ConCab kabel connects the world

CC-Schleppflex Sensor-Actuator PUR-567


and Distribution Cable
Superflexible data cable for machine installations
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 567 4 x 0,25 E172073  STYLE 20233 300V 80C DESINA

Technical data
Rated voltage:

DIN VDE/IEC :
UL/CSA :

Also available pre-assembled with


sockets and connectors.

300 V
300 V

Test voltage:
1200 V

The CC-Schleppflex Sensor-Actuator PUR-567 and


distribution cable have been designed for special
installation and control technology applications.
Pre-assembled with sockets and connectors, it grants
high flexibility to make adjustments, extentions or
changes at automation lines.

Construction
Superfine strands of bare copper wire, PVC-based or
Polypropylene core insulation, core colours as
described in the table below, cores twisted in layers.
PUR outer sheath, extensively resistant to oil and
cooling liquid, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1), non-adhesive, resistant
to hydrolysis and microbes.
Colour DESINA -yellow (RAL 1021)
or black (RAL 9005).
Part-No.

No. of cores

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Insulation resistance:

min. 20 MOhm X km

Core colours

+
crosssection

567 0002 003


567 0002 004
567 0002 005

3 X 0,25
4 X 0,25
5 X 0,25

567 0003 003


567 0003 004
567 0003 005

3 X 0,34
4 X 0,34
5 X 0,34

104 26 001
145 94 001
145 94 002
*without 

Temperature range:

fixed installation:
flexible application:
flexible application halogen-free:

Sensor-Actuator Cable outer sheath yellow


bn, bu, bk
bn, bu, bk, wh
bn, bu, bk, wh, gnye

bn, bu, bk
bn, bu, bk, wh
bn, bu, bk, wh, gnye
Distribution Cable outer sheath black
8 X 0,34 + 3 X 1* bk with No. 1 to 8
bn, bu, gnye,
16 X 0,5 + 3 X 1* bk, whgy, whye, whgn, gypk, gn, rdbu, gy, rd,
vt, gybn, pk, ye, wh, bngn, yebn + bu, bn, gnye
16 X 0,5 + 3 X 1* bk, whgy, whye, whgn, gypk, gn, rdbu, gy, rd,
vt, gybn, pk, ye, wh, bngn, yebn + bu, bn, gnye
halogen-free

-30C to +80C
-5C to +80C
-20C to +80C

Bending radius:

7,5 X cable diameter

Approvals:

acc. to DIN VDE 0245, 0281, 0812


UL: Style 20233 DESINA
Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

7,2
9,6
12,0

4,4
4,7
5,1

23
25
32

9,8
13,1
16,3

5,0
5,3
5,9

29
43
55

55,2

9,7

139

110,0

11,4

200

110,0

11,4

200

155

CC-BUS-CABLES
Fieldbus

Norm

Part-No.

Type

Application

 

PROFIBUS
(SUCOnet P,
Modulink P,)
up to 500 kbit/s

DIN 19245
part 1+2
EN 50170

93 022 016
93 022 026
94 025 016
94 025 026

BUS-PVC-C (1 X 2 X 0,22)
BUS-PVC-C (2 X 2 X 0,22)
BUS-Schleppflex-PUR-C (1 X 2 X 0,25)
BUS-Schleppflex-PUR-C (2 X 2 X 0,25)

fixed installation
fixed installation
flexible
flexible

a
a
a
a

PROFIBUS DP
(SINEC L2
SIMATICNET F.I.P)
up to 12 Mbit/s

DIN 19245 part 3


EN 50170

93 064 0161
93 064 0163
93 064 0164
93 064 0102
93 064 01310
93 064 01415
94 024 016
94 024 0164
94 064 01310
94 064 01415

BUS-PVC-C (1 X 2 X 0,64 )
BUS-H-C (1 X 2 X 0,64 ) halogen-free
BUS-PVC-C (1 X 2 X 0,64 ) FASTCONNECT
BUS-PVC-C (1 X 2 X 0,64 ) black, buried in ground, UV-resistant
BUS-PVC-C (1 X 2 X 0,64 ) + 3 X 1
BUS-PVC-C (1 X 2 X 0,64 ) + 4 X 1,5
BUS-Schleppflex-PUR-C (1 X 2 X 0,64 )
BUS-Schleppflex-PUR-C (1 X 2 X 0,64 ) FASTCONNECT
BUS-Schleppflex-PUR-C (1 X 2 X 0,64 ) + 3 X 1
BUS-Schleppflex-PUR-C (1 X 2 X 0,64 ) + 4 X 1,5

fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
flexibel
flexibel
flexibel
flexibel

a
a
a
a
a
a
a
a
a
a

a
a
a
a

Page
158
158
160
160
158
158
158
158
158
158
160
160
160
160

PROFIBUS PA
for explosive areas

DIN 19245
EN 50170

95 18 111
95 18 110
95 18 911
95 18 910
95 18 9114
95 18 9104

BUS-PA 02Y(St)CY 1 X 2 X AWG 18/1 blue


BUS-PA 02Y(St)CY 1 X 2 X AWG 18/1 black
BUS-PA 02Y(St)CY 1 X 2 X AWG 18/19 blue
BUS-PA 02Y(St)CY 1 X 2 X AWG 18/19 black
BUS-PA 02Y(St)CY 1 X 2 X AWG 18/19 blue FASTCONNECT
BUS-PA 02Y(St)CY 1 X 2 X AWG 18/19 black FASTCONNECT

fixed installation
fixed installation
flexible
flexible
flexible
flexible

CAN
up to 1 Mbit/s

ISO 11898

93 022 016
93 022 026
93 034 016
93 034 026
93 050 016
93 050 026
93 075 016
93 075 026
94 025 016
94 025 026
94 034 016
94 034 026
94 050 016
94 050 026

BUSPVC-C (1 X 2 X 0,22)
BUSPVC-C (2 X 2 X 0,22)
BUSPVC-C (1 X 2 X 0,34)
BUSPVC-C (2 X 2 X 0,34)
BUSPVC-C (1 X 2 X 0,50)
BUSPVC-C (2 X 2 X 0,50)
BUSPVC-C (1 X 2 X 0,75)
BUSPVC-C (2 X 2 X 0,75)
BUS-Schleppflex PUR-C (1 X 2X 0,25)
BUS-Schleppflex PUR-C (2 X 2X 0,25)
BUS-Schleppflex PUR-C (1 X 2X 0,34)
BUS-Schleppflex PUR-C (2 X 2X 0,34)
BUS-Schleppflex PUR-C (1 X 2X 0,50)
BUS-Schleppflex PUR-C (2 X 2X 0,50)

fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
flexibel
flexibel
flexibel
flexibel
flexibel
flexibel

a
a
a
a
a
a
a
a
a
a
a
a
a
a

a
a
a
a
a
a
a
a
a
a
a
a
a
a

166
166
166
166
166
166
166
166
167
167
167
167
167
167

INTERBUS
SENSOR-/
ACTOR-BUS

DIN 19258
EN 50254

93 022 036
93 022 03001
94 025 036
94 025 03601

BUSPVC-C (3 X 2 X 0,22)
BUSPVC-C (2 X 2 X 0,22 + 3 X 1) Yv
BUS-Schleppflex PUR-C (3 X 2X 0,25)
BUS-Schleppflex PUR-C (3 X 2X 0,25 + 3 X 1)

fixed installation
fixed installation
flexibel
flexibel

a
a
a
a

a
a
a
a

158
158
160
160

BITBUS

IEEE 1118

93 022 036
94 025 036

BUSPVC-C (3 X 2 X 0,22)
BUS-Schleppflex PUR-C (3 X 2 X 0,25)

fixed installation
flexibel

a
a

a
a

158
160

DIN-Me-BUS

DIN66348
ISO 8482

93 022 036
94 025 036

BUSPVC-C (3 X 2 X 0,22)
BUS-Schleppflex PUR-C (3 X 2 X 0,25)

fixed installation
flexibel

a
a

a
a

158
160

93 021 510
93 021 519
93 022 1510
93 022 1519
93 052 1510
93 052 1519
93 07215 10
93 07215 19

BUS AS-I 2 X 1,5 black


BUS AS-I 2 X 1,5 yellow
BUS AS-I 2 X 1,5 black
BUS AS-I 2 X 1,5 yellow
BUS AS-I 2 X 1,5 black
BUS AS-I 2 X 1,5 yellow
BUS AS-I 2 X 1,5 black
BUS AS-I 2 X 1,5 yellow

flexibel
flexibel
flexibel
flexibel
flexibel
flexibel
flexibel
flexibel

910 11511805
910 11511806
910 12212405
910 12212406
912 12212406
911 11511809
911 11511806
911 12212409
911 12212406

Thick Cable 1 X 2 X AWG 15 + 1 X 2 X AWG 18 grey


Thick Cable 1 X 2 X AWG 15 + 1 X 2 X AWG 18 violet
Thick Cable 1 X 2 X AWG 22 + 1 X 2 X AWG 24 grey
Thick Cable 1 X 2 X AWG 22 + 1 X 2 X AWG 24 violet
Thick Cable 1 X 2 X AWG 22 + 1 X 2 X AWG 24 violet, halogen-free
Schleppflex Thick Cable 1 X 2 XAWG 15 + 1 X 2X AWG 18 yellow
Schleppflex Thick Cable 1 X 2 XAWG 15 + 1 X 2X AWG 18 violet
Schleppflex Thick Cable 1 X 2 XAWG 22 + 1 X 2X AWG 24 yellow
Schleppflex Thick Cable 1 X 2 XAWG 22 + 1 X 2X AWG 24 violet

AS-INTERFACE

DeviceNet

Trademark of:
INTERBUS

VariNet-P
DESINA

Phoenix Contact GmbH & Co.

Pepperl + Fuchs GmbH


VDW

SIMATEC NET, SINEC Siemens AG


Foundation Fieldbus
Fieldbus Foundation

156

SUCOnet P
DeviceNet O

Modulink P
PROFInet
SAFETY Bus

PVC/TPE
PVC/TPE
PVC/PVC
PVC/PVC
PP/PUR halogen-free
PP/PUR halogen-free
EPDM
EPDM

Klckner Moeller GmbH


DVA (Open DeviceNet Vendors Association)
Weidmller GmbH & Co.
PNO (PROFIBUS Nutzerorganisation)
Pilz GmbH & Co. KG

fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
flexible
flexible
flexible
flexible

176
176
176
176
176
176

a
a

a
a

a
a
a
a
a
a
a
a
a

a
a
a
a
a
a
a
a
a

168
168
168
168
168
168
168
168
172
172
172
172
172
173
173
173
173

CC-BUS-CABLES
Fieldbus

Norm

EIB

Part-No.

Type

Application

  Page

425 0800210
BUS-EIB J-Y(St)Yv 2 X 2 X 0,8mm
480 0800210
BUS-EIB J-Y(St)Yv 2 X 2 X 0,8mm, halogen-free
425 3150800 210 BUS-EIB Hybrid J-Y(St)Yv 2 X 2 X0,8mm + 3 X 1,5mm

fixed installation
fixed installation
fixed installation

170
170
170

931 40152980
931 50152980
931 40252980
931 50252980

BUS-Schleppflex Hybrid-PUR 4 G 1,5 + 2 P980/1000


BUS-Schleppflex Hybrid-PUR 5 G 1,5 + 2 P980/1000
BUS-Schleppflex Hybrid-PUR 4 G 2,5 + 2 P980/1000
BUS-Schleppflex Hybrid-PUR 5 G 2,5 + 2 P980/1000

flexibel
flexibel
flexibel
flexibel

171
171
171
171

471 2402 15310


471 2402 25310
471 2402 35310
471 2404 15310
471 2404 25310
471 2404 35310
471 2602 15310
471 2604 15310
471 2402 45310
471 2404 45310
471 2604 45310

Ether-BUS-C (2 X 2 X AWG 24/1)


Ether-BUS-C (2 X 2 X AWG 24/1)
Ether-BUS-C (2 X 2 X AWG 24/1)
Ether-BUS-C (4 X 2 X AWG 24/1)
Ether-BUS-C (4 X 2 X AWG 24/1)
Ether-BUS-C (4 X 2 X AWG 24/1)
Ether-BUS-C (2 X 2 X AWG 26/7)
Ether-BUS-C (4 X 2 X AWG 26/7)
Schleppflex-Ether-BUS-C (2 X 2 X AWG 24/19)
Schleppflex-Ether-BUS-C (4 X 2 X AWG 24/19)
Schleppflex-Ether-BUS-C (4 X 2 X AWG 26/19)

fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
fixed installation
flexible
flexible
flexible

174
174
174
174
174
174
174
174
175
175
175

PROFInet

471 2202 45310

Schleppflex-Ether-BUS-C (2 X 2 X AWG 22/7)

flexible

175

SAFETY-BUS

94 075 03 09

CC-BUS-SAFETY-PUR (3 X 0,75)

fixed installation

LON-BUS

935 123 120 06


931 602 06

CC-LONBUS-C (1 X 2 XAWG 23/1 + 2 X AWG 20/1)


CC-LONBUS 1 X 2 XAWG 16

fixed installation
fixed installation

a
a

163
163

Foundation
Fieldbus

913 1 18 18 09
913 1 18 09

CC-BUS-FF-C 1 X 2 XAWG 18 + 1 X AWG 18


CC-BUS-FF-C 1 X2XAWG18

fixed installation
fixed installation

a
a

164
164

Hybrid-BUS

DESINA
EN 50173

ETHERBUS
TCP/IP
up to 100 Mbit/s
CAT 5

162

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548

ConCab kabel connects the world

157

CC-BUS PVC-C-93 / CC-BUS H-C-93


Fieldbus cable, shielded

ConCab kabel Mainhardt BUS-C-93 1x2x0,22 E172073 CUS AWM STYLE 20963 1000V 80C DESINA

CC-BUS PVC-C-93 is used for linking industrial fieldbus systems in automation and communication technology.
CC-Bus cables meet high industrial standards, such as INTERBUS-S, CAN, PROFIBUS and SINEC L2.
The cables between bus-users are an important intermediary link and set high standards for exact data
transmission.

Construction
(1 X 2 X 0,22 mm) bis (3 X 2 X 0,22 mm)
Bare, 7-strands of copper wires, PP core insulation.
Core colours acc. to DIN 47100, cores twisted to pairs
and laid in layers, 2 pair version twisted to star quad,
special foil wrapping, tinned copper shield. PVCbased outer sheath, resistant to oil and cooling liquids,
flame retardant and self-extinguishing (acc. to VDE
0482, part 265-2-1 resp. EN 50265-2-1 and IEC
60332-1).
(3 X 2 X 0,22 mm2 + 3 X 1 mm) Yv
Bare, 7-strands (0,22 mm2) resp. superfine
(1 mm2) copper wires, core insulation 0,22 mm2:
PP resp. 1 mm2: polyester (TPE),
core colours for 0,22 mm2 acc. to DIN 47100,
core colours for 1 mm2 rd, bl, gnye. Cores and pairs
twisted in layers, fleece, tinned copper shield.
Enforced PVC-based outer sheath, extensively
resistant to oil and cooling liquid, flame retardant and
self-extinguishing ( acc. to DINVDE 0482
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
UV- resistant, for in-and outdoor use and
for direct burial.
(1 X 2 X 0,64 mm)
Bare solid copper wire, cellular-PE core insulation,
core colours green and red, cores tiwsted in pairs,
aluminium foil, overall tinned copper shield.
PVC-based outer sheath, resistant to oil and cooling
liquid, flame retardant and self-extinguishing ( acc. to
DINVDE 0482 part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1).
(1 X 2 X 0,64 mm) FASTCONNECT
Construction as standard 1 X 2 X 0,64 mm, but with
additional PVC-based inner sheath for easy strip.

158

(1 X 2 X 0,64 mm) halogen-free


Construction as standard 1 X 2 X 0,64 mm, but with
halogeen free outer sheath based on special polymer
mixture, resistant to oil and cooling liquid, flame retardant and self-extinguishing (acc. to DINVDE 0482
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
(1 X 2 X 0,64 mm) Yv
Construction as standard 1 X 2 X 0,64 mm, but with
enforced PVC-based outer sheath, resistant to oil and
cooling liquid, flame retardant and self-extinguishing
(acc. to DINVDE 0482 part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1), UV- resistant, for
in-and outdoor use and for direct burial.
(1 X 2 X 0,64 mm) + 3 X 1 mm2
0,64 mm: bare solid copper wire, cellular-PE core
insulation core colours green and red, cores twisted to
pairs, aluminium foil, overall tinned copper shield.
1 mm2: bare fine strands of copper wire, PVC-based
core insulation, core colours black, blue and gnye.
Cores and pairs twisted together, fleece. PVC-based
outer sheath, resistant to oil and cooling liquid, flame
retardant and self-extinguishing (acc. to DINVDE
0482 part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
(1 X 2 X 0,64 mm) + 4 X 1,5 mm2
0,64 mm: bare solid copper wire, cellular-PE core
insulation, core colours green and red, cores twisted to
pairs, aluminium foil, overall tinned copper shield.
1,5 mm2: bare, fine strands of copper wire, PVC-based
core insulation, black cores with consecutive white
numbering. Cores and pairs twisted together, fleece.
PVC-based outer sheath, resistant to oil and cooling
liquid, flame retardant and self-extinguishing (acc. to
DINVDE 0482 part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).

ConCab kabel connects the world

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

violet*
violet*
violet*
black

18,0
20,0
37,0
67,5

5,3
5,6
7,5
9,5

35
42
78
92

violet*
violet*
violet*
black
violet*
violet *

25,0
25,0
25,0
25,0
49,0
81,0

7,6
7,8
8,0
10,0
9,5
11,0

62
62
62
120
88
149

Outer
sheath
colour

+
cross-section/ diameter
93 022 016
93 022 026
93 022 036
93 022 03001

(1 X 2 X 0,22)  and 
(2 X 2 X 0,22)  and 
(3 X 2 X 0,22)  and 
(3 X 2 X 0,22 + 3 X 1) Yv

93 064 0161
93 064 0163
93 064 0164
93 064 0102
93 064 01310
93 064 01415

SINEC L2 (1 X 2 X 0,64 )
SINEC L2 (1 X 2 X 0,64 ) halogen-free
SINEC L2 (1 X 2 X 0,64 ) FAST CONNECT
SINEC L2 (1 X 2 X 0,64 ) Yv
SINEC L2 (1 X 2 X 0,64 ) + 3 X 1
SINEC L2(1 X 2 X 0,64 ) +4 X 1,5

 and 





 and 

* Colour acc. to DESINA standard

Technical data
Rated voltage:
300 V, not for power
applications at 0,22 mm, 0,64 mm

Temperature range:

fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Test voltage:
0,22 mm, 0,64 mm: 1000 V

15 X cable diameter

Loop resistant:

cUL: Style 2464, 2919, 2571, 20963

Bending radius:

1 mm: 2500 V

0,22 mm: max. 120 Ohm/km


1 mm: max. 40 Ohm/km
0,64 mm: max. 110 Ohm/km

Approvals:

Operating capacity at 800 Hz:

0,22 mm: core/core max. 60 nF/km


0,64 mm: core/core max. 30 nF/km

Impedance:

0,22 mm: 100 -120 Ohm


0,64 mm:
150 Ohm

ConCab kabel connects the world

159

CC-BUS-Schleppflex PUR-C-94
Superflexible halogen-free fieldbus cable, shielded

ConCab kabel Mainhardt BUS-Schleppflex-C-94 1x2x0,25 E172073 CUS STYLE 20549 300V 80C DESINA

CC-BUSPUR-C-94 is used for linking industrial fieldbus systems in automation and communication technology. CC-Bus cables meet high industrial standards, such as INTERBUS-S, CAN, PROFIBUS and
SINEC L2. The cables between bus-users are an important intermediary link and set high standards for
exact data tranmission. The special contruction also allows the BUS-cable to be used for power supply
chains and automatic handling equipment.

Construction
(1 X 2 X 0,25 mm2) bis (3 X 2 X 0,25 mm2)
Superfine strands of bare copper wires, PPcore insulation. Core colours acc. to DIN 47100, cores twisted
to pairs and layed in layers, tinned copper shield.
PUR-based outer sheath, non-adhesive and resistant to
hydrolysis and microbes, flame retardant and selfextinguishing (acc. to VDE DIN VDE 0482
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
(3 X 2 X 0,25 mm2 + 3 X 1 mm2)
Superfine strands of bare copper wires, PP core
insulation for cores of
0,25 mm2 resp. polyester (TPE) for cores of 1 mm2.
Core colours for 0,25 mm2 acc. to DIN 47100, core
colours for 1 mm2 rd, bl and gnye. Cores and pairs
twisted together, overall tinned copper braid.
PUR-based outer sheath, non-adhesive and resistant
to hydrolysis and microbes, flame retardant and selfextinguishing (acc. to VDE DIN VDE 0482
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
(1 X 2 X 0,64 mm)
Superfine strands of bare copper wires, cellular-PE
core insulation, core colours green and red.
Cores twisted to pairs, aluminium foil, overall tinned
copper braid. PUR-based outer sheath
non-adhesive and resistant to hydrolysis and
microbes, flame retardant and self-extinguishing
(acc. to VDE DIN VDE 0482 Teil 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
FASTCONNECT (1 x 2 x 0,64 mm)
Contruction as standard 1 X 2 X 0,64 mm, but with
additional PVC-based inner sheath over the pairs:
Advantage of FASTCONNECT cable for easy strip.

160

(1 X 2 X 0,64 mm) + 3 X 1 mm2


0,64 mm: superfine strands of bare copper
wires, cellular-PE core insulation. Core colours
green and red, cores twisted to pairs, aluminium
foil, overall tinned copper braid.
1 mm2: superfine strands of bare copper wires,
polyester (TPE) core insulation. Core colours bk,
bl and gnye. Cores and pairs twisted together in
layers. PUR-based outer sheath, non-adhesive and
resistant to hydrolysis and microbes, flame retardant and self-extinguishing (acc. to VDE DIN
VDE 0482 Teil 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1).
(1 X 2 X 0,64 mm) + 4 X 1,5 mm2
0,64 mm: bare superfine strands of copper
wires, cellular-PE core insulation. Core colours
green and red, aluminium foil, overall
tinned copper shield.
1,5 mm2: superfine strands of bare copper wires,
polyester (TPE) core insulation. Core colours
black with consecutive white numbering. Cores
and pairs twisted together in layers. PUR-based
outer sheath, non-adhesive and resistant
to hydrolysis and microbes, flame retardant and
self-extinguishing (acc. to VDE DIN VDE 0482
part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).

ConCab kabel connects the world

Part-No.

No. of cores
+

Outer
sheath
colour

cross-section/ diameter

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

94 025 016
94 025 026
94 025 036
94 025 03601

(1 2 0,25)  and 
(2 2 0,25)  and 
(3 2 0,25)  and 
(3 2 0,25 + 3 1)  and 

violet
violet
violet
violet

18,0
34,8
39,0
72,0

5,2
8,0
8,2
9,3

41
72
81
92

94 024 016
94 024 0164
94 064 01310
94 064 01415

SINEC L2 (1 2 0,64) 
SINEC L2 (1 2 0,64) FAST CONNECT 
SINEC L2 (1 2 0,64) + 3 1 
SINEC L2 (1 2 0,64) + 4 1,5  and 

violet
violet
violet
violet

28,0
28,0
55,0
89,0

7,8
8,0
9,5
11,0

78
78
98
152

Technical data
Rated voltage:

Impedance:

300 V, not for power


applications at 0,25 mm2, 0,64 mm

Test voltage:
0,25 mm2, 0,64 mm: 1000 V
1 mm2: 2500 V

0,25 mm2: 100 -120 Ohm


0,64 mm:
150 Ohm

Temperature range:

fixed installation:
flexible application:

-40C to +80C
-30C to +70C

fixed installation:
flexible application:

8 X cable diameter
15 X cable diameter

Conductor stranding:

superfine copper strands


acc. to DIN VDE 0295, class 6

Loop resistance:

0,25 mm2: max. 185 Ohm/km


0,64 mm: max. 133 Ohm/km

Bending radius:

Approvals:

cUL: Style 20549, 20910

Operating capacity at 800 Hz:

0,25 mm2: core/core max. 60 nF/km


0,64 mm: core/core max. 30 nF/km

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

161

CC-BUS-SAFETY PUR-C-94
Halogen-free SAFETY-Bus cable

ConCab kabel Mainhardt BUS-Safety-C-94 3x0,75 E172073 CUS STYLE 20549 300V 80C DESINA

CC-BUS SAFETY PUR-C-94 is used in automation and communication technology for connecting safety
relevant components and safety control units as well as for the direct connections of sensors and actors.

Technical data
Rated voltage:
250 V, not for power application
UL: 300V

Test voltage:
2500 V

Construction
(3x0,75mm2)
Bare, fine strands of copper wires, halogen-free core
insulation, core colours white, brown and green.
Overall tinned copper braid, PUR-based outer sheath,
non-adhesive, resistant to hydrolisis and microbes,
flame retardant and self-extinguising (acc. to DIN
VDE 0482 part 265-2-1 resp. EN 50265-2-1 and IEC
60332-1). Colour yellow (RAL 1003).

Conductor stranding:

fine copper strands

Impedance:

120 Ohm

Resistance:

conductor resistance (loop) at 20C 52 Ohm/km

Operating capacity at 800 Hz:


45 nF/km

Temperature range:

flexible application:
fixed installation:

Bending radius:

Max. bitrate:
500 MBit/s at 100m
250 kBit/s at 250m
125 kBit/s at 500m
50 kBit/s at 1000m
Part-No.

Type

No. of cores
+
crosssection

94 075 03 09

162

SAFETY-Bus

(3 0,75)

-30C to +70C
-40C to +80C

15 X core diameter

Norms:

cUL: Style 20549


Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

49,0

7,8

75,0

ConCab kabel connects the world

CC-LONBUS C-935
shielded

ConCab kabel Mainhardt LON-CNP EN14908-2 93512312006

Technical data
Rated voltage:

150 V

Test voltage:
4000 V

The CC-LON-BUS cable is used for integrated


building automation. This bus-system consists of one
pair of power cores and one pair of data transmission
cores on CAT basis.

Conductor stranding:
power cores:
AWG 20 (0,8 mm)
data cores:
AWG 23 (0,57 mm)

Construction
Bare solid conductor.
Data transmission cores: Core insulation
cellular PE, core colours are white and orange.
Power cores: Core insulation polyethylene,
core colours are red and blue.
Data and power cores twisted together,
tinned drain wire, one pair shielded in aluminium foil.
Outer sheath of halogen-free polymere mixture, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1/
EN 50265-2-1 and IEC 60332-1).
Part-No.

Type

Loop resistance:
data pair: 100 Ohm
Temperature range:
fixed installation:
-25C to +70C
flexible application:
0C to +70C
Bending radius:
fixed installation: 5 X core diameter
flexible application: 10 X core diameter

No. of cores
+

Outer
sheath
colour

AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

935 123 180 06

LON-Bus

12AWG 23/1 + 2AWG 20/1

violet

18,0

7,6

65,0

931 3602 06

LON-Bus

12AWG 16

violet

36,5

4,4

71,0

Special needs, different dimensions or different outer sheath upon request.


For installation instructions please see page 548.

ConCab kabel connects the world

163

CC-BUS-FF-PVC-C-913
Foundation fieldbus, shielded

ConCab kabel Mainhardt BUS-FF-PVC-C 1x2xAWG 18 E172073 CUS STYLE 20549 300V 80C DESINA

The CC-Foundation fieldbus shielded, is used for


process automation well-known on Anglo-American
markets.This bus-system consists of one pair of cores
for data transmission. The cable is used to connect
sensors and actors.

Construction
Fine strands of tinned copper wires.
PE core insulation. Cores twisted to pairs,
tinned drain wire, overall shield of aluminium foil.
PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
EN 50265-2-1 and IEC 60332-1).

Technical Data
Rated voltage:
300 V
Test voltage:

Part-No. 913 118 18 09


3 cores without armouring with Device Ground. Core
colours blue, brown and green/yellow. Outer sheath
yellow.

1500 V

Conductor stranding:

AWG 18

Loop resistance:

Part-No. 913 118 09


2 cores without armouring with Device Ground.
Core colours blue and brown. Outer sheath yellow.

164

data pair: 100-120 Ohm

Temperature range:

Part-No. 914 118 18 09


3 cores with longitudinal spiral copper tape with
Device Ground. Core colours blue, brown and
green/yellow. Outer sheath yellow.

fixed installation:
flexible application:
CMG:

-30C to +80C
0C to +80C

+105C

Part-No. 914 118 18 01


3 cores with longitudinal spiral copper tape with
Device Ground. Core colours blue, brown and
green/yellow. Outer sheath blue.

fixed installation:

15 X core diameter

Bending radius:

Norms:

Foundation Fieldbus spec. FF 816-14

ConCab kabel connects the world

Part-No

No. of cores
+
crosssection/AWG

Outer
sheath
colour

Copper
weight
kg/km

913 118 18 09
913 118 09
914 118 18 09
914 118 18 01

1 X 2 X AWG 18 + 1 X AWG 18
1 X 2 X AWG 18
1 X 2 X AWG 18 + 1 X AWG 18
1 X 2 X AWG 18 + 1 X AWG 18

yellow
yellow
yellow
blue

61,6
65,0
107,0
107,0

ConCab kabel connects the world

Outer Weight
diameter
approx.
mm

kg/km

7,9
7,9
12,3
12,3

93,0
94,0
184,0
184,0

165

CC-BUS CAN-PVC-C-93
CAN-Bus, shielded

ConCab kabel Mainhardt CAN-BUS-C-93 1x2x0,22 E172073 CUS STYLE 2464 300V 80C DESINA

CC-BUS CAN-PVC-C-93 shielded is used for linking industrial fieldbus systems in automation and
communication technology. CC-Bus cables meet high industrial standards, such as INTERBUS-S, CAN
and PROFIBUS. The cables between bus-users are an important intermediary link and set the high standards
for exact data transmission. CC-BUS-CAN-PVC-C-93 (Controller Area Network) is extensively used for
industrial applications for connecting indoor networks. The max. bitrate is up to 1MBit/s. With increasing
segment lengths a larger cross-sections should be used.

Construction

Technical data

(1 X 2 X 0,22 mm2) to (2 X 2 X 0,75 mm2)


Bare, fine strands of copper wires, PP resp.
cellular PE core insulation, core colours acc.
to DIN 47100, cores twisted in pairs, 2 pairs laid in
a star quad, foil wrapping, tinned copper shield,
PVC-based outer sheath, resistant to oil and coolants,
flame retardant and self-extinguishing (acc. to
DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour DESINA violet.

Rated voltage:
300 V, not for power applications
Test voltage:
1000 V
Impedance:

100 - 120 Ohm

Temperature range:

fixed installation:
flexible application:
ISO 11898 recommends the following:
Segment length
up to 40 m
40 - 300 m
300 - 600 m
600 -1000 m
Part-No.

Cross-section

+
cross-section
93
93
93
93
93
93
93
93

166

022
022
034
034
050
050
075
075

016
026
016
026
016
026
016
026

Bending radius:

(1 X 2 X 0,22)
(2 X 2 X 0,22)
(1 X 2 X 0,34)
(2 X 2 X 0,34)
(1 X 2 X 0,50)
(2 X 2 X 0,50)
(1 X 2 X 0,75)
(2 X 2 X 0,75)










15 X cable diameter

Max. bitrate

1 MBit/s
0,22 mm2 up to 0,34 mm2
0,34 mm2 up to 0,6 mm2 > 500 kBit/s
0,50 mm2 up to 0,6 mm2 > 100 kBit/s
0,75 mm2 up to 0,8 mm2 > 50 kBit/s
No. of cores

-40C to +80C
-5C to +70C

Approvals:

at 40 m
at 100 m
at 500 m
at 1000 m

ISO 11898
cUL: Style 2919

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

18,0
24,0
21,8
27,4
27,0
38,0
35,0
55,0

5,3
5,6
6,2
6,4
7,0
7,2
8,5
8,6

35
42
60
68
73
80
103
115

ConCab kabel connects the world

CC-BUS-Schleppflex CAN-PUR-C-94
Superflexible halogen-free CAN-Bus cable, shielded

ConCab kabel Mainhardt CAN-BUS-C-93 1x2x0,22 E172073 CUS STYLE 2464 300V 80C DESINA

CC-BUS Schleppflex CAN-PUR-C-94 shielded is used for linking industrial fieldbus systems in automation
and communication technology. CC-Bus cables meet high industrial standards, such as INTERBUS-S, CAN
and PROFIBUS. The cables between bus-users are an important intermediary link and set-high standards for
exact data transmission. CC-BUS Schleppflex CAN-PUR-C-94 (Controller Area Network) is used industrially
in power supply chains. The max. bitrate is up to 1MBit/s. With increasing segment length larger cross-sections
should be used.

Technical data

Construction

Rated voltage:
300 V, not for power applications

(1 X 2 X 0,25 mm2) to (2 X 2 X 0,5 mm2)


Superfine strands of bare copper wires, PP resp.
cellular PE core insulation, core colours acc. to DIN
47100, cores twisted in pairs, two pairs laid in star
quad, overall tinned copper shield, PUR-based outer
sheath, non-adhesive, resistant to hydrolysis and
microbes, flame retardant and self-extinguishing (acc.
to DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1). Colour DESINA -violet.

Test voltage:
1000 V
Impedance:

100 - 120 Ohm

Temperature range:

fixed installation:
flexible application:

Bending radius:

ISO 11898 recommends the following:


Segment length
up to 40 m
40 - 300 m
300 - 600 m
600 -1000 m
Part-No.

Max. bitrate

1 MBit/s
0,22 mm up to 0,34 mm
0,34 mm2 up to 0,6 mm2 > 500 kBit/s
0,50 mm2 up to 0,6 mm2 > 100 kBit/s
0,75 mm2 up to 0,8 mm2 > 50 kBit/s
2

No. of cores
+
cross-section

94 025 016
94 025 026
94 034 016
94 034 026
94 050 016
94 050 026

15 X cable diameter

Cross-section
2

-40C up to +80C
-30C up to +70C

Approvals:

at 40 m
at 100 m
at 500 m
at 1000 m

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

ISO 11898
cUL: Style 20963, 20549

18,0
5,6
41
(1 X 2 X 0,25)
 and 
34,8
8,0
72
(2 X 2 X 0,25)
 and 
20,0
6,2
53
(1 X 2 X 0,34)

26,0
5,9
60
(2 X 2 X 0,34)

27,0
7,0
67
(1 X 2 X 0,50)

40,0
7,0
75
(2 X 2 X 0,50)

Special needs, different dimensions or different outer sheath colours upon request.
For installation instructions please see page 548.

ConCab kabel connects the world

167

CC-BUS AS-Interface
AS-I Fieldbus cable

ConCab kabel Mainhardt 930

ConCab kabel Mainhardt 930

The Sensor-Actuator-Interface-Cable (AS-I) is


used in network systems for the lowest field
level of automation and communication
technology. This flat cable consists of two
unshielded cores which transmit the data and
energy. The contact is made by special
technology by piercing through the outer
sheath and core insulation within
the AS-I modules.

Rubber EPDM
Fine strands of bare copper wires, rubber
based core insulation, core colours blue and brown.
EPDM outer sheath.

Technical data
Rated voltage:
300 V

Construction

Test voltage:
2000 V

PVC/TPE
Fine strands of tinned copper wires, PVC core
insulation, core colours blue and brown.
Polyester (TPE) outer sheath.
EPR/PUR Halogen free
Fine strands of bare copper wires, EPRcore
insulation, core colours blue and brown,
PUR outer sheath.

Insulation resistance:

min. 20 MOhm X km

PVC/PVC 
Fine strands of tinned copper wires, PVC core
insulation, core colours blue and brown.
PVC outer sheath.

168

Temperature range:

fixed installation :
flexible application :

ConCab kabel connects the world

-40C to +80C
-20C to +80C

Bending radius:

10 X cable thickness
Approvals:
UL: Style 2103

Part-No.

No. of cores
+

Outer
sheath
colour

cross-section

Copper
weight

Weight

kg/km

kg/km

930 21510
930 21519

PVC/TPE for power supply chains


black
CC-Bus AS-I 2 X 1,5
yellow
CC-Bus AS-I 2 X 1,5

930 5215 10
930 5215 19

EPR/PUR Halogen-free, for power supply chains


CC-Bus AS-I 2 X 1,5
black
28,8
CC-Bus AS-I 2 X 1,5
yellow
28,8

28,8
28,8

55
55

67
67

930 2215 10
930 2215 19

PVC/PVC 
CC-Bus AS-I 2 X 1,5
CC-Bus AS-I 2 X 1,5

black
yellow

28,8
28,8

55
55

930 7215 10
930 7215 19

Rubber EPDM
CC-Bus AS-I 2 X 1,5
CC-Bus AS-I 2 X 1,5

black
yellow

28,8
28,8

55
55

For installation instructions please see page 548.

ConCab kabel connects the world

169

CC-BUS-EIB J-Y(St)Yv Bd-425


Halogen-free CC-BUS-EIB J-H(St)Hv Bd-480
European Installation-Bus cable

ConCab kabel Mainhardt BUS-EIB 2x2x0,8

Technical data
Rated voltage:

250 V, not for power applications

Test voltage:

core against water bath: 4000 V


CC-BUS-EIB-425 and -480 cable
meet the requirements of the
European Installation-Bus-standard (EIB).
These Bus-cables are used for data transmission in
building management control systems for power and
low voltage applications. They can be used in dry,
wet or damp areas either inside or outside, but not
laid in the ground.

Conductor stranding:

bare solid conductor acc. to


DIN VDE 0295, class 1

Loop resistance:

130 Ohm/km

Core insulation and outer sheath:

Construction

J-Y(St)Hv:
PVC
J-H(St)Hv: halogen-free
polymere mixture

Solid bare copper conductor. For core insulation,


please see table. Core colours:
group 1: a-core red, b-core black,
group 2: a-core white, b-core yellow.
4 cores laid in star quad,
copper drain wire, aluminium foil.
Outer sheath is flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1, resp. IEC 60332-3).
Colour green.

Insulation resistance:

min. 100 MOhm X km

Capacity at 800 Hz:

max. 100 nF/km

Attenuation at 800 Hz:

approx. 1,2 dB/km

Temperature range:

fixed installation:
Part-No.

No. of cores

Copper
weight

+
diameter
425 08 002 10
480 08 002 10
425 08 002 315 10

170

J-Y(St)Yv 2 X 2 X 0,8

Outer Weight
diameter
approx.

kg/km

mm

kg/km

21

6,8

64

J-H(St)Hv 2 X 2 X 0,8 halogen-free

21

6,8

70

J-Y(St)Yv 2 X 2 X 0,8 + 3 X 1,5

64

12,7

128

-30C to + 70C

Bending radius:

one-time bending without tensile force:


3,5 X cable diameter
multiple bending under tensile force or
during transport: 10 X cable diameter

ConCab kabel connects the world

Approvals:

acc. to DIN VDE 0815 and EIB

CC-BUS-Schleppflex Hybrid-PUR 931


High flexible fieldbus composite cable with POF

ConCab kabel Mainhardt BUS-Schleppflex-931 4G1,5+2P980/1000 DESINA

Technical data

CC-Bus-Schleppflex Hybrid-PUR 931 is


used for the connection of DESINAconform automatic equipments and
machines. 4 respectively 5 copper cores
are used for the power supply. The plastic
optical fibre (POF) cores secure the exact
transmission of digital control signals
without any electromagnetic disturbances.
The special construction of
CC-Bus-Schleppflex Hybrid enables the
cable to be used in mobile power supply
chains and automatic handling equipment.

Rated voltage:
300/500 V

Test voltage:
3000 V

Conductor stranding:

superfine copper strands


acc. to DIN VDE0295, class 6

Insulation resistance:

min. 20 MOhm X km

Construction

Fibre type:

Superfine strands of bare copper wires,


PVC-based core insulation, cores are black
with consecutive white numbering and a
green/yellow protective conductor. Cores
and POF-Fibres are layed around a
central filling core, aramid strength
members. PUR-based outer sheath, flame
retardant and self-extinguishing (acc. to
DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour DESINA-violet (RAL 4001).

POF-step index fibre


core diameter: 980 m
sheath diameter: 1000 m

Attenuation:

max. 200 dB/km at 650 nm

Temperature range:

fixed installation:
flexible application:

-30C to +70C
-5C to +70C

Bending radius:

8 X cable diameter

Approvals:

acc. to DESINA specification


Part-No.

Copper
weight

Outer
diameter
approx.

Weight

Max.
tensile
strength

cross-section/fibre type

kg/km

mm

kg/km

931 4015 2980*


931 5015 2980

4 G 1,5 + 2P980/1000
5 G 1,5 + 2P980/1000

3000
3000

58,0
72,0

10,2
11,0

136
170

931 4025 2980*


931 5025 2980

4 G 2,5 + 2P980/1000
5 G 2,5 + 2P980/1000

3000
3000

96,0
129,0

12,3
13,2

206
256

No. of cores

*DESINA conforming

ConCab kabel connects the world

171

CC-BUS PVC-C-910
Fieldbus cable for DeviceNet, shielded

ConCab kabel Mainhardt BUS-C-910 12AWG15+12AWG18 cus

Technical Data
Rated voltage:
300 V
Test voltage:
1500 V

Conductor stranding:

The CC-BUS PVC-C-910 shielded, used for


DeviceNet installations, is especially
known in Anglo-American markets.
This Bus-system consists of one pair of power cores
and one pair of data transmission cores on a CAN
basis. The trunk cable is used as the backbone cable.
The Thin cable connects sensors and actors to the
backbone Thick cable.

power cores:
Thick cable: AWG 15 (1,5 mm2)
Thin cable: AWG 22 (0,34 mm2)
data cores:
Thick cable: AWG 18 (1,0 mm2)
Thin cable: AWG 24 (0,25 mm2)

Loop resistance:

data pair: 100-120 Ohm

Construction
Fine strands of tinned copper wires.
Data transmission cores: Cellular-PE core
insulation, core colours are blue and white.
Power cores: Polyester (TPE) core insulation, core
colours are red and black.
Data and power cores are each twisted into a pair,
tinned drain wire, each pair shielded in aluminium
foil, overall tinned copper shield. PVC outer sheath,
flame retardant and self-extinguishing (acc. to DIN
VDE 0482, part 265-2-1/ EN 50265-2-1 and
IEC 60332-1).

Part-No.

Type

Temperature range:

fixed installation:
flexible application:

-20C to +70C
0C to +70C

fixed installation:
flexible application:

7,5 X core diameter


15 X core diameter

Bending radius:

Approvals:

*(UL) CM or Style 2570, CSA: AWM I/II A/B


**(UL) CM or Style 2571, CSA: AWM I/II A/B
***cUL: CMX

No. of cores
+
AWG

Outer
sheath
colour

Gewicht

kg/km

Outer
diameter
approx.
mm

Copper
weight

kg/km

910 115 118 05


910 122 124 05

Thick Cable
Thin Cable

1X2XAWG15 + 1X2XAWG18*
1X2XAWG22 + 1X2XAWG24**

grey
grey

84,9
32,6

12,2
7,1

210
65

910 115 118 06


910 122 124 06

Thick Cable
Thin Cable

1X2XAWG15 + 1X2XAWG18*
1X2XAWG22 + 1X2XAWG24**

violet
violet

84,9
32,6

12,2
7,1

210
65

912 122 124 06

Thin Cable halogen-free**** 1 X 2 X AWG22 + 1 X 2 X AGW24***

violet

32,6

8,0

64

****halogen-free PUR-outer sheath

172

ConCab kabel connects the world

CC-BUS-Schleppflex PUR-C-911
High flexible halogen-free fieldbus cable for DeviceNet, shielded

ConCab kabel Mainhardt BUS-Schleppflex-C-911 12AWG15+12AWG18 E172073 cus

Technical data
Rated voltage:
300 V

The CC-BUS-Schleppflex-PUR-C-911 shielded


UL/CSA is used for DeviceNet installations,
especially known in Anglo-American markets. This
Bus-system consists of one pair of power cores and
one pair of data transmission cores on a CAN basis.
The Thick cable is used as the backbone cable. The
Thin cable connects sensors and actors to the
backbone Thick cable. The PUR outer sheath enables
the cable to be used in mobile power supply chains
and automatic handling equipment.

Test voltage:
1500 V

Conductor stranding:

power cores:
Thick cable: AWG 15 (1,5 mm2)
Thin cable: AWG 22 (0,34 mm2)
data cores:
Thick cable: AWG 18 (1,0 mm2)
Thin cable: AWG 24 (0,25 mm2)

Construction

Loop resistance:

data pair: 100-120 Ohm

Superfine strands of tinned copper wires.


Data transmission cores: Core insulation
cellular PE, core colours are blue and white.
Power cores: Core insulation polyester (TPE),
core colours are red and black.
Data and power cores are each twisted into a pair,
tinned drain wire, each pair shielded in aluminium
foil, overall tinned copper shield.
PUR outer sheath, flame retardant
and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1/
EN 50265-2-1 and IEC 60332-1).
Part-No.

Type

Temperature range:

fixed installation:
flexible application:

-40C to +70C
0C to +70C

Bending radius:

fixed installation: 7,5 X core diameter


flexible application: 15 X core diameter

Approvals:

*cUL: Style 20910


**cUL: Style 20233

No. of cores
+

Outer
sheath
colour

AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

911 115 118 09


911 122 124 09

Schleppflex-Thick Cable
Schleppflex-Thin Cable

1X2XAWG 15 + 1X2XAWG 18*


1X2XAWG 22 + 1X2XAWG 24**

yellow
yellow

93,2
35,2

12,2
7,0

209
64

911 115 118 06


911 122 124 06

Schleppflex-Thick Cable
Schleppflex-Thin Cable

1X2XAWG 15 + 1X2XAWG 18*


1X2XAWG 22 + 1X2XAWG 24**

violet
violet

93,2
35,2

12,2
7,0

209
64

Special needs, different dimensions or different outer sheath upon request.


For installation instructions please see page 548.

ConCab kabel connects the world

173

CC-Ether-BUS-C-(TP)-471
Halogen-free ETHERNET-fieldbus cable, shielded CAT 5/100 MHz

ConCab kabel Mainhardt BUS-C-(TP)-471 4x2xAWG24 DESINA

CC-Ether-BUS-C-(TP)-471 is used for wiring industrial fieldbus systems in automation and communication
technology and meets high industrial standards, such as INTERBUS-S, CAN, PROFIBUS and SINEC L2.
The cables between bus-users are an important intermediary link and set high standards for exact data transmission.

Technical data
Rated voltage:

150 V, not for power applications


Test voltage:
Core/core: 500 V
Core/shield: 800 V

CC-Ether-Bus-C-(TP)-471 shielded is designed as a


TCP/IP-Fieldbus cable for ETHERNET-Networks
applications in rough industrial environments and for
transmission rates of up to CAT 5/100 MHz.
Solid conductor is used for permanent installation
whereas 7-wire conductor is used for
flexible installation.

Conductor stranding:

AWG 24: solid wire, 0,52 mm


AWG 26: 7 wires, 0,15 mm

Loop resistance:

AWG 24: max. 190 Ohm/km


AWG 26: max. 265 Ohm/km

Construction

Impedance:

Bare solid conductor or 7-wires copper conductor.


Cellular-PE core insulation,
core colours whbu/bu, whog/og.
Added colours for 4-paired types: whgn/gn, whbn/bn.
Cores twisted in pairs or quads and pairs laid in layers,
aluminium foil shield, overall
tinned copper shield. Outer sheath as stated below.
Colour DESINA green (RAL 6018).

Part-No.

Type

No. of cores
+

100 Ohm 15 Ohm

Temperature range:
fixed installation:
-30C to +70C
flexible application:
-5C to +50C
fixed installation:
flexible application:
Outer
sheath
material

AWG

174

Outer
diameter
approx.

Weight

mm

kg/km

471 2402 15310


471 2402 25310
471 2402 35310

SF/UTP
SF/UTP
SF/UTP

(2 X 2 X AWG 24/1)
(2 X 2 X AWG 24/1)
(2 X 2 X AWG 24/1)

H
PUR
H+PUR

5,8
5,8
7,7

53
60
71

471 2404 15310


471 2404 25310
471 2404 35310

SF/UTP
SF/UTP
SF/UTP

(4 X 2 X AWG 24/1)
(4 X 2 X AWG 24/1)
(4 X 2 X AWG 24/1)

H
PUR
H+PUR

6,5
6,5
8,0

56
64
82

471 2602 15310


471 2604 15310

Patchcable SF/UTP
Patchcable SF/UTP

(2 X 2 X AWG 26/7)
(4 X 2 X AWG 26/7)

H
H

5,6
5,7

36
44

Bending radius:

5 X cable diameter
10 X cable diameter

Approvals:

acc. to EN50173

CC-Schleppflex-Ether-BUS-C-(TP)-471
High flexible halogen-free ETHERNET-fieldbus cable, shielded
CAT 5/100 MHz

ConCab kabel Mainhardt - 471 4 x 2 x AWG 24 DESINA

CC-Ether-BUS-C-(TP)-471 shielded is used for wiring industrial fieldbus systems in automation and
communication technology and meets high industrial standards, such as INTERBUS-S, CAN, PROFIBUS
and SINEC L2.The cables between bus-users are an important intermediary link and set high standards for
exact data transmission.

Technical data
Rated voltage:

CC-Schleppflex-Ether-Bus-C-(TP)-471 highly flexible


can be used in mobile power supply chain and as a
TCP/IP-Fieldbus cable for ETHERNET-Networks for
applications in rough industrial environments and for
transmission rates of up to CAT 5/100 MHz.

150 V, not for power applications

Construction

AWG 22: 7-wires 0,25 mm


AWG 24: 19-wires 0,14 mm
AWG 26: 19-wires 0,10 mm

Test voltage:
core/core: 500 V
core/shield: 800 V

Conductor stranding:

Bare 7- or 19-wires copper conductor, PP core


insulation, core colours whbu/bu, whog/og. PROFInet
ws, ge, bl, or. Added colours for 4 paired types:
whgn/gn, whbn/bn. Cores twisted in pairs or quads and
pairs laid in layers,
aluminium foil shield, overall tinned copper shield.
PUR outer sheath. Colour DESINA
green (RAL 6018).

Loop resistance:

AWG 22: max. 120 Ohm/km


AWG 24: max. 200 Ohm/km
AWG 26: max. 250 Ohm/km

Impedance:

100 Ohm 15 Ohm

Temperature range:
fixed installation:
-30C to +70C
flexible application:
-5C to +50C
fixed installation:
flexible application:
Part-No.

No. of cores

Type

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

25,0
45,0
29,7
31,3

6,2
8,0
6,9
6,5

+
AWG
471 2402 45310
471 2404 45310
471 2604 45310
471 2202 45310

Schleppflex SF/UTP
Schleppflex SF/UTP
Schleppflex Patchcable SF/UTP
Schleppflex SF/UTP PROFInet

(2 X 2 X AWG 24/19)
(4 X 2 X AWG 24/19)
(4 X 2 X AWG 26/19)
(2 X 2 X AWG 22/7)
FAST CONNECT

Bending radius:

5 X cable diameter
10 X cable diameter

Approvals:

acc. to EN50173
cUL: Style 20910
cUL: Style 20233

65
82
60
61

Special needs, different dimensions or different outer sheath upon request.


For installation instructions please see page 548.

ConCab kabel connects the world

175

CC-BUS PROFIBUS PA-C-95


Fieldbus cable for application in explosive areas

ConCab kabel Mainhardt BUS-PA-95 1 x 2 x AWG 18/1 CE

CC-BUS PA-C-95 PROFIBUS PA is used for linking industrial fieldbus systems in automation and
communication technology. The CC-Bus cable meets high industrial standards, such as INTERBUS-S,
CAN, PROFIBUS and SINEC L2. The cables between bus-users are an important intermediary link and set
high standards for exact data transmission. CC-Bus PA-C-95 has been developed specifically for processautomation (PA) in explosive areas.

Technical data
Rated voltage:

250 V, not for power applications

Test voltage:
1500 V

Loop resistance:

max. 44 Ohm/km

Construction
Solid conductor or 19-wires of bare
copper wire, cellular-PE core insulation, core colours
red and green, cores twisted into a pair, foil,
aluminium foil shield, overall tinned copper shield.
PVC-based outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332.1).
Colour blue (for intrinsically safe power circuits)
or colour black.

176

ConCab kabel connects the world

Impedance:

at 31,25 kHz: 80-120 Ohm

Temperature range:
-30C to +60C

Bending radius:

10 X cable diameter

Approvals:

DIN19245, EN50170

Part-No.

No. of cores

Sheath
colour

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

34,0
34,0
34,0
34,0
34,0
34,0

7,8
7,8
7,8
7,8
7,8
7,8

65
65
74
65
65
74

+
AWG
95 181 11
95 189 11
95 189 114
95 181 10
95 189 10
95 189 104

1 X 2 X AWG 18/1
1 X 2 X AWG 18/19
1 X 2 X AWG 18/19 FAST CONNECT
1 X 2 X AWG 18/1
1 X 2 X AWG 18/19
1 X 2 X AWG 18/19 FAST CONNECT

blue
blue
blue
black
black
black

ConCab kabel connects the world

177

178

179

CC-control cable-JZ-110
Numbered black cores
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 110 25G1,5 JZ

Technical data
Rated voltage:
300/500 V

Test voltage:
4000 V
The flexible CC-control cable PVC-JZ-110 is suitable as a
guiding, controlling and measuring cable especially when
free unrestricted movement is required. It can be used in the
construction of machine tools, plant and appliances, as well
as in heating, air conditioning and ventilation
technology and other spheres of application in electrical
units. The outer sheath, based on PVC, is extremely resistant
to oil and chemicals. It is free of silicone, cadmium and free
of harmful substances.

Construction
Fine strands of bare copper wire with PVC core insulation,
cores black with consecutive white numbering.
3 cores or more with green/yellow protective conductor in
the outer layer. Cores twisted in layers. PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

180

Conductor stranding:
fine copper strands
acc. to DINVDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

110 0005 002


110 0005 003
112 0005 003
110 0005 004
112 0005 004
110 0005 005
112 0005 005
110 0005 006
110 0005 007
112 0005 007
110 0005 008
110 0005 010
110 0005 012
112 0005 012
110 0005 014
110 0005 016
110 0005 018
110 0005 021
110 0005 025
110 0005 030
110 0005 034
110 0005 035
110 0005 040
110 0005 050
110 0005 052
110 0005 061
110 0005 065
110 0005 080
110 0005 100

2 X 0,5
3 G 0,5
3 X 0,5
4 G 0,5
4 X 0,5
5 G 0,5
5 X 0,5
6 G 0,5
7 G 0,5
7 X 0,5
8 G 0,5
10 G 0,5
12 G 0,5
12 X 0,5
14 G 0,5
16 G 0,5
18 G 0,5
21 G 0,5
25 G 0,5
30 G 0,5
34 G 0,5
35 G 0,5
40 G 0,5
50 G 0,5
52 G 0,5
61 G 0,5
65 G 0,5
80 G 0,5
100 G 0,5

110 0007 002


110 0007 003
112 0007 003
110 0007 004
112 0007 004
110 0007 005
112 0007 005
110 0007 006
110 0007 007
112 0007 007
110 0007 008
112 0007 008
110 0007 009

2 X 0,75
3 G 0,75
3 X 0,75
4 G 0,75
4 X 0,75
5 G 0,75
5 X 0,75
6 G 0,75
7 G 0,75
7 X 0,75
8 G 0,75
8 X 0,75
9 G 0,75

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg/km
9,6
14,4
witho. gnye
19,2
witho. gnye
24,0
witho. gnye
28,8
34,0
witho. gnye
38,4
47,6
58,0
witho. gnye
67,0
77,0
86,0
101,0
120,0
144,0
163,0
168,0
192,0
240,0
250,0
293,0
312,0
384,0
480,0

5,0
5,3
5,3
5,8
5,8
6,5
6,5
7,0
7,0
7,0
8,1
9,2
9,4
9,4
9,7
10,4
11,5
12,3
13,3
14,0
14,8
15,4
16,5
18,2
18,2
20,3
20,9
22,6
25,2

35
42
42
50
50
64
64
79
82
82
101
126
136
136
164
185
201
246
263
334
366
380
441
566
590
608
673
790
960

14,4
21,6
witho. gnye
29,0
witho. gnye
36,0
witho. gnye
43,2
50,0
witho. gnye
58,0
witho. gnye
65,0

5,6
5,8
5,8
6,4
6,4
6,9
6,9
7,5
7,5
7,5
9,0
9,0
9,8

46
54
54
66
66
79
79
98
105
105
131
131
155

Part-No.

No. of cores
+
crosssection

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg / km

110 0007 010


110 0007 011
110 0007 012
112 0007 012
110 0007 015
110 0007 018
110 0007 021
110 0007 025
110 0007 034
110 0007 041
110 0007 042
110 0007 050
110 0007 061
110 0007 065
110 0007 080
110 0007 100

10 G 0,75
72,0
11 G 0,75
79,2
12 G 0,75
86,0
12 X 0,75 witho. gnye
15 G 0,75
108,0
18 G 0,75
130,0
21 G 0,75
151,0
25 G 0,75
180,0
34 G 0,75
245,0
41 G 0,75
295,0
42 G 0,75
302,0
50 G 0,75
360,0
61 G 0,75
439,0
65 G 0,75
468,0
80 G 0,75
576,0
100 G 0,75
720,0

9,9
10,2
10,2
10,2
11,2
12,0
13,3
14,0
16,2
18,0
18,0
19,6
22,1
23,0
24,3
27,8

155
165
172
172
206
246
291
332
448
554
559
655
804
837
1018
1300

110 0010 002


110 0010 003
112 0010 003
110 0010 004
112 0010 004
110 0010 005
112 0010 005
110 0010 006
110 0010 007
112 0010 007
110 0010 008
110 0010 009
110 0010 010
110 0010 012
112 0010 012
110 0010 014
110 0010 018
112 0010 018
110 0010 020
110 0010 021
110 0010 025
110 0010 034
110 0010 036
110 0010 041
110 0010 042
110 0010 050
110 0010 056
110 0010 061
110 0010 065
110 0010 080
110 0010 100

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
5 X 1,0
6 G 1,0
7 G 1,0
7 X 1,0
8 G 1,0
9 G 1,0
10 G 1,0
12 G 1,0
12 X 1,0
14 G 1,0
18 G 1,0
18 X 1,0
20 G 1,0
21 G 1,0
25 G 1,0
34 G 1,0
36 G 1,0
41 G 1,0
42 G 1,0
50 G 1,0
56 G 1,0
61 G 1,0
65 G 1,0
80 G 1,0
100 G 1,0

5,9
6,2
6,2
6,7
6,7
7,3
7,3
8,2
8,2
8,2
9,7
10,4
10,5
10,6
10,6
11,5
13,0
13,0
13,8
14,4
14,9
17,5
18,0
19,1
19,1
21,0
23,7
24,6
25,9
27,6
30,1

53
63
63
76
76
94
94
124
133
133
158
181
187
202
202
236
302
302
339
362
402
549
620
658
664
794
880
954
1006
1245
1600

ConCab kabel connects the world

19,2
29,0
witho. gnye
38,0
witho. gnye
48,0
witho. gnye
58,0
67,0
witho. gnye
77,0
86,4
96,0
115,0
witho. gnye
134,0
173,0
witho. gnye
192,0
202,0
240,0
326,0
346,0
394,0
403,0
480,0
538,0
586,0
624,0
768,0
960,0

181

CC-control cable-JZ-110
Numbered black cores
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of cores
+
crosssection

110 0015 002


110 0015 003
112 0015 003
110 0015 004
112 0015 004
110 0015 005
112 0015 005
110 0015 006
110 0015 007
112 0015 007
110 0015 008
110 0015 009
110 0015 010
110 0015 011
110 0015 012
112 0015 012
110 0015 014
110 0015 016
110 0015 018
110 0015 021
110 0015 025
110 0015 032
110 0015 034
110 0015 041
110 0015 042
110 0015 050
110 0015 061
110 0015 065
110 0015 080
110 0015 100

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
6 G 1,5
7 G 1,5
7 X 1,5
8 G 1,5
9 G 1,5
10 G 1,5
11 G 1,5
12 G 1,5
12 X 1,5
14 G 1,5
16 G 1,5
18 G 1,5
21 G 1,5
25 G 1,5
32 G 1,5
34 G 1,5
41 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5
80 G 1,5
100 G 1,5

29,0
43,0
witho. gnye
58,0
witho. gnye
72,0
witho. gnye
86,0
101,0
witho. gnye
115,0
130,0
144,0
158,5
173,0
witho. gnye
202,0
230,4
259,0
302,0
360,0
461,0
490,0
591,0
605,0
720,0
878,0
936,0
1152,0
1440,0

6,5
6,9
6,9
7,4
7,4
8,3
8,3
9,1
9,1
9,1
9,1
11,3
11,7
11,7
12,0
12,0
12,9
13,7
14,7
16,4
17,2
17,5
19,7
21,3
21,5
23,9
25,6
27,0
29,8
36,9

67
82
82
100
100
122
122
150
159
159
208
223
247
262
277
277
312
361
400
487
539
704
727
895
889
1069
1282
1372
1677
2300

110 0025 002


110 0025 003
112 0025 003
110 0025 004
110 0025 005
112 0025 005
110 0025 007
110 0025 009
110 0025 012
110 0025 014
110 0025 018
110 0025 025
110 0025 034
110 0025 050

2 X 2.5
3 G 2.5
3 X 2.5
4 G 2.5
5 G 2.5
5 X 2.5
7 G 2.5
9 G 2.5
12 G 2.5
14 G 2.5
18 G 2.5
25 G 2.5
34 G 2.5
50 G 2.5

48,0
72,0
witho. gnye
96,0
120,0
witho. gnye
168,0
216,0
288,0
336,0
432,0
600,0
816,0
1200,0

7,7
8,3
8,3
9,1
10,2
10,2
12,6
13,6
15,0
16,1
18,1
21,1
24,7
30,1

98
124
124
154
192
192
247
400
423
490
622
829
1150
1698

182

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg/km

Part-No.

No. of cores
+
crosssection

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg / km

110 0040 002


110 0040 003
110 0040 004
112 0040 004
110 0040 005
110 0040 007
110 0040 011
110 0040 012

2X4
3G4
4G4
4X4
5G4
7G4
11 G 4
12 G 4

76,8
115,2
154,0
witho. gnye
192,0
269,0
422,0
461,0

8,9
10,1
11,0
11,0
12,3
13,6
17,6
20,2

186
196
241
241
301
389
634
800

110 0060 003


110 0060 004
110 0060 005
110 0060 007

3G6
4G6
5G6
7G6

172,8
230,0
288,0
403,0

11,9
13,1
14,6
16,1

281
354
440
570

110 0100 003


110 0100 004
110 0100 005
110 0100 007

3 G 10
4 G 10
5 G 10
7 G 10

288,0
384,0
480,0
672,0

14,7
16,3
18,2
20,2

451
573
711
930

110 0160 003


110 0160 004
112 0160 004
110 0160 005
110 0160 007

3 G 16
4 G 16
4 X 16
5 G 16
7 G 16

461,0
614,0
witho. gnye
768,0
1075,0

18,3
23,0
23,0
25,6
28,3

872
1066
1066
1316
1691

110 0250 003


110 0250 004
110 0250 005
110 0250 007

3 G 25
4 G 25
5 G 25
7 G 25

720,0
960,0
1200,0
1680,0

23,0
27,3
30,5
34,0

1280
1538
1911
2477

110 0350 003


110 0350 004
110 0350 005

3 G 35
4 G 35
5 G 35

1008,0
1344,0
1680,0

27,0
31,5
34,7

1680
2086
2542

110 0500 003


110 0500 004

3 G 50
4 G 50

1440,0
1920,0

31,3
36,7

2550
2960

110 0700 003


110 0700 004

3 G 70
4 G 70

2016,0
2688,0

39,4
44,3

3181
4204

110 0950 003


110 0950 004

3 G 95
4 G 95

2736,0
3648,0

43,7
51,5

4678
5618

110 1200 003


110 1200 004

3 G 120
4 G 120

3456,0
4608,0

47,6
55,5

5620
6824

ConCab kabel connects the world

CC-control cable-JB-111
Coloured cores
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 111 5x1,5 JB

Technical data
Die flexible CC-control cable PVC-JB-111 is
suitable as a guiding, controlling and
measuring cable especially when free
unrestricted movement is required. It can be used in
the construction of machine tools, plant and
appliances, as well as in heating, air conditioning,
ventilation technology and other spheres of
application in electrical equipment. The outer sheath,
based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone and cadmium and
free of harmful substances.

Rated voltage:
300/500 V

Test voltage:
4000 V

Conductor stranding:
fine copper strands
acc. to DINVDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire with PVC core
insulation, up to 5 cores, colours
acc. to DIN VDE 0293 part 308. 6 cores or more acc.
to CC-colour code (see technical appendix).
3 cores or more with green/yellow
protective conductor in the outer layer.
Cores twisted in layers. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DINVDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

183

CC-control cable-JB-111
Coloured cores
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of cores
+
crosssection

111 0005 002


111 0005 003
113 0005 003
111 0005 004
113 0005 004
111 0005 005
113 0005 005
111 0005 006
111 0005 007
111 0005 008
111 0005 010
111 0005 012
111 0005 014
111 0005 016
111 0005 018
111 0005 021
111 0005 025
111 0005 030
111 0005 034
111 0005 040
111 0005 050
111 0005 052
111 0005 061

2 X 0,5
3 G 0,5
3 X 0,5
4 G 0,5
4 X 0,5
5 G 0,5
5 X 0,5
6 G 0,5
7 G 0,5
8 G 0,5
10 G0,5
12 G 0,5
14 G 0,5
16 G 0,5
18 G 0,5
21 G 0,5
25 G 0,5
30 G 0,5
34 G 0,5
40 G 0,5
50 G 0,5
52 G 0,5
61 G 0,5

9,6
14,4
witho. gnye
19,2
witho. gnye
24,0
witho. gnye
28,8
34,0
38,4
47,6
58,0
67,0
77,0
86,0
101,0
120,0
144,0
163,0
192,0
240,0
250,0
293,0

5,0
5,3
5,3
5,8
5,8
6,5
6,5
6,8
7,0
8,1
9,2
9,4
9,7
10,4
11,5
12,3
13,3
14,0
14,8
16,5
18,2
18,2
20,3

35
42
42
50
50
64
64
79
73
101
126
136
164
185
201
246
263
334
366
441
566
590
608

111 0007 002


111 0007 003
113 0007 003
111 0007 004
113 0007 004
111 0007 005
113 0007 005
111 0007 006
111 0007 007
111 0007 008
111 0007 009
111 0007 010
111 0007 012
111 0007 015
111 0007 018
111 0007 021
111 0007 025
111 0007 040
111 0007 050

2 X 0,75
14,4
3 G 0,75
21,6
3 X 0,75 witho. gnye
4 G 0,75
29,0
4 X 0,75 witho. gnye
5 G 0,75
36,0
5 X 0,75 witho. gnye
6 G 0,75
43,2
7 G 0,75
50,0
8 G 0,75
58,0
9 G 0,75
65,0
10 G 0,75
72,0
12 G 0,75
86,0
15 G 0,75
108,0
18 G 0,75
130,0
21 G 0,75
151,0
25 G 0,75
180,0
40 G 0,75
277,0
50 G 0,75
360,0

5,6
5,8
5,8
6,4
6,4
6,9
6,9
7,5
7,5
9,0
9,8
9,9
10,1
11,2
12,0
13,3
14,0
18,8
19,8

46
54
54
66
66
79
79
98
105
131
155
155
172
206
246
291
332
571
655

184

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg/km

Part-No.

No. of cores
+
crosssection

111 0010 002


111 0010 003
113 0010 003
111 0010 004
113 0010 004
111 0010 005
113 0010 005
111 0010 006
111 0010 007
111 0010 008
111 0010 009
111 0010 010
111 0010 012
111 0010 014
111 0010 016
111 0010 018
111 0010 020
111 0010 025

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
5 X 1,0
6 G 1,0
7 G 1,0
8 G 1,0
9 G 1,0
10 G 1,0
12 G 1,0
14 G 1,0
16 G 1,0
18 G 1,0
20 G 1,0
25 G 1,0

19,2
29,0
witho. gnye
38,4
witho. gnye
48,0
witho. gnye
58,0
67,0
77,0
86,4
96,0
115,0
134,0
153,6
173,0
192,0
240,0

5,9
6,2
6,2
6,7
6,7
7,3
7,3
8,0
8,2
9,7
10,4
10,5
10,6
11,5
11,8
13,0
13,8
14,9

50
70
70
78
78
100
100
113
129
160
180
190
220
250
266
310
340
425

111 0015 002


111 0015 003
113 0015 003
111 0015 004
113 0015 004
111 0015 005
113 0015 005
111 0015 007
111 0015 008
111 0015 009
111 0015 010
111 0015 011
111 0015 012
111 0015 014
111 0015 018
111 0015 021
111 0015 025
111 0015 032

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
7 G 1,5
8 G 1,5
9 G 1,5
10 G 1,5
11 G 1,5
12 G 1,5
14 G 1,5
18 G 1,5
21 G 1,5
25 G 1,5
32 G 1,5

29,0
43,0
witho. gnye
58,0
witho. gnye
72,0
witho. gnye
101,0
115,0
130,0
144,0
158,0
173,0
202,0
259,0
302,0
360,0
461,0

6,5
6,9
6,9
7,4
7,4
8,3
8,3
9,1
10,9
11,3
11,7
11,7
12,0
12,9
14,7
16,4
17,2
17,5

67
83
83
106
106
134
134
173
205
223
247
290
277
361
400
487
539
704

ConCab kabel connects the world

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg / km

Part-No.

No. of cores
+
crosssection

Copper
weight

111 0025 002


111 0025 003
111 0025 004
111 0025 005
111 0025 007
111 0025 008

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
8 G 2.5

48.0
72.0
96,0
120,0
168,0
192,0

7,7
8,3
9,1
10,2
12,6
14,7

98
124
154
192
247
380

111 0040 002


111 0040 004
111 0040 005
111 0040 007

2X4
4G4
5G4
7G4

76,8
154,0
192,0
296,0

8,9
11,0
12,3
13,6

166
241
301
389

111 0060 003


111 0060 004
111 0060 005
111 0060 007

3G6
4G6
5G6
7G6

172,8
230,0
288,0
403,0

11,9
13,1
14,6
16,1

281
354
440
470

111 0100 003


111 0100 004
111 0100 005
111 0100 007

3 G 10
4 G 10
5 G 10
7 G 10

288,0
384,0
480,0
672,0

14,7
16,3
18,2
20,2

451
573
711
930

111 0160 003


111 0160 004
111 0160 005

3 G 16
4 G 16
5 G 16

461,0
614,0
768,0

18,3
23,0
25,6

872
1066
1316

111 0250 003


111 0250 004
111 0250 005

3 G 25
4 G 25
5 G 25

720,0
960,0
1200,0

23,0
27,3
30,5

1388
1538
1911

111 0350 003


111 0350 004
111 0350 005

3 G 35
4 G 35
5 G 35

1000,0
1344,0
1680,0

27,0
31,5
34,7

1760
2086
2542

111 0500 003


111 0500 004

3 G 50
4 G 50

1440,0
1920,0

31,3
36,7

2550
2960

111 0700 003


111 0700 004

3 G 70
4 G 70

2016,0
2688,0

39,4
44,3

3181
4204

111 0950 003


111 0950 004

3 G 95
4 G 95

2736,0
3648,0

43,7
51,5

4673
5618

111 1200 003


111 1200 004

3 G 120
4 G 120

3456,0
4608,0

47,6
55,5

5620
6824

111 1500 004


111 1850 004

4 G 150
4 G 185

5760,0
7104,0

60,2
62,4

8475
9680

kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

ConCab kabel connects the world

185

CC-control cable-101 (blue cores)


CC-control cable-102 (red cores)
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 101 12x1,5

ConCab kabel Mainhardt 102 12x1,5

Technical data
Rated voltage:
300/500 V
The flexible CC-control cable PVC-101 (blue cores)
resp. -102 (red cores) are highly suitable as guiding,
controlling and measuring cables especially when free
unrestricted movement is required. It can be used in
the construction of machine tools, plant and
appliances, as well as in heating, air conditioning,
ventilation technology and other spheres of
application in electrical equipment. The outer sheath,
based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone, cadmium and
free of harmful substances.

Test voltage:
4000 V

Conductor stranding:
fine copper strands
acc. to DINVDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire with PVC core
insulation, red or resp. blue core colours with
consecutive white numbering. Control cables
with 3 cores or more with
green/yellow protective conductor in the
outer layer. Cores twisted in layers.
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

186

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

blue cores
101 0010 004
101 0010 005
101 0010 007
101 0010 012
101 0010 018
101 0010 025

4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

38,0
48,0
67,0
115,0
173,0
240,0

6,7
7,8
8,7
11,8
14,0
17,5

86
100
129
225
334
485

101 0015 002


101 0015 003
101 0015 004
101 0015 005
101 0015 007
101 0015 012
101 0015 018
101 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

6,6
7,0
7,9
9,0
9,8
13,6
16,4
19,4

67
83
106
134
173
313
460
637

red cores
102 0010 004
102 0010 005
102 0010 007
102 0010 008
102 0010 012
102 0010 018
102 0010 020
102 0010 025

4 G 1,0
5 G 1,0
7 G 1,0
8 G 1,0
12 G 1,0
18 G 1,0
20 G 1,0
25 G 1,0

38,0
48,0
67,0
77,0
115,0
173,0
192,0
240,0

6,7
7,8
8,7
9,7
11,8
14,0
14,8
17,5

86
100
129
175
225
334
375
485

102 0015 002


102 0015 003
102 0015 004
102 0015 005
102 0015 007
102 0015 012
102 0015 018
102 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

29,0
43,0
58,0
72,0
102,0
173,0
259,0
360,0

6,6
7,0
7,9
9,0
9,8
13,6
16,4
19,4

67
83
106
134
173
313
460
637

Different dimensions available on request

ConCab kabel connects the world

187

CC-control cable blue-JZ-107 and OZ-117


For intrinsically safe circuits
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 117 25G1,0 OZ

Technical data
Rated voltage:
300/500 V
The CC-control cable blue PVC-JZ-107 resp.
OZ-117 conform to DIN VDE 0165 section 12.2.2
and are highly suitable as guiding, controlling and
measuring cables. These cables for intrinsically safe
circuits are assembled with the ignition protection i
acc. to DIN VDE. For the individual stipulations of
special applications, refer to DIN VDE 0165.
The outer sheath, based on PVC, is extremely
resistant to oil and chemicals. It is free of silicone,
cadmium and free of harmful substances.

Construction
Fine strands of bare copper wire with PVC core
insulation. Cores black with consecutive white
numbering. Control cables with or without
green/yellow protective conductor in the outer layer.
Cores twisted in layers. PVC outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Colour blue (RAL 5015).

188

Test voltage:
3000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

107 0007 003


107 0007 004
107 0007 005
107 0007 007
107 0007 012
107 0007 018
107 0007 025

3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75

21,6
29,0
36,0
50,0
86,0
130,0
180,0

6,3
6,9
7,5
8,2
11,0
12,8
14,9

51
78
100
125
210
270
410

107 0010 003


107 0010 004
107 0010 005
107 0010 007
107 0010 012
107 0010 018
107 0010 025

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

29,0
38,4
48,0
67,0
115,0
173,0
240,0

6,8
7,3
8,0
8,7
11,6
14,0
16,6

64
106
123
149
260
350
470

107 0015 003


107 0015 004
107 0015 005
107 0015 007
107 0015 012
107 0015 018
107 0015 025

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

43,0
58,0
72,0
101,0
173,0
258,0
360,0

7,6
8,3
9,3
10,1
13,7
16,6
18,7

83
116
145
195
314
460
637

kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

117 0007 002


117 0007 003
117 0007 004
117 0007 005
117 0007 007
117 0007 008
117 0007 012
117 0007 018
117 0007 025

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
12 X 0,75
18 X 0,75
25 X 0,75

14,4
21,6
29,0
36,0
50,0
58,0
86,0
130,0
180,0

6,1
6,3
6,9
7,5
8,2
9,6
11,0
12,8
14,9

43
66
78
84
118
138
189
282
400

117 0010 002


117 0010 003
117 0010 004
117 0010 005
117 0010 007
117 0010 012
117 0010 018
117 0010 025

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
7 X 1,0
12 X 1,0
18 X 1,0
25 X 1,0

19,2
29,0
38,4
48,0
67,0
115,0
173,0
240,0

6,4
6,8
7,3
8,0
8,7
11,6
14,0
16,6

50
60
106
115
140
225
334
485

117 0015 002


117 0015 003
117 0015 004
117 0015 005
117 0015 007
117 0015 012
117 0015 018
117 0015 025

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
7 X 1,5
12 X 1,5
18 X 1,5
25 X 1,5

29,9
43,0
58,0
72,0
101,0
173,0
258,0
360,0

7,3
7,6
8,3
9,3
10,1
13,7
16,6
18,7

67
110
125
145
195
314
460
637

ConCab kabel connects the world

189

CC-control cable orange-JZ-08


For closing and locking units
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 08 5G1,5 JZ

The CC-control cable orange PVC-JZ-08 as per VDE


0113 resp. EN 60204, part 1 is used for closing and
locking units. Our safety regulations stipulate that
power supply cables are of orange colour. The electric
circuit is always supplied from outside to ensure that
when the main switch is off, the closing and locking
mechanism still functions. The outer sheath, based on
PVC, is extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free of
harmful substances.

Technical data

Construction
Fine strands of bare copper wire
with PVC core insulation.
Cores orange with consecutive black
numbers. 3 cores or more with green/yellow
protective conductor in the outer layer.
Cores twisted in layers. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour orange (RAL 2003).
Part-No.

190

No. of cores
+
crosssection

Copper
weight
kg/km

Outer diameter
approx.
mm

08 0010 002 2
08 0010 003 1
08 0010 003 2
08 0010 004 1
08 0010 004 2
08 0010 005 1

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0

19,2
29,0
witho. gnye
38,4
witho. gnye
48,0

5,9
6,2
6,2
6,7
6,7
7,3

53
63
63
76
76
94

08 0015 002 2
08 0015 003 1
08 0015 004 1
08 0015 005 1

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

29,0
43,0
58,0
72,0

6,5
6,9
7,4
8,3

67
82
100
122

Rated voltage:
300/500 V

Test voltage:
4000 V

Conductor stranding:
fine copper strands
acc. to DINVDE 0295, class 5

Insulation resistance:

Weight

min. 20 MOhm X km

kg/km

Temperature range:
fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

CC-control cable yellow-JB-09


For warning systems
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 09 5G1,5 JB

The CC-control cable yellow PVC-JB-09 is used for


warning systems. After the main switch has been
switched off, the system is still voltage-carrying as it
has to fulfil its warning function. The outer sheath,
based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone, cadmium and free of
harmful substances.

Technical data

Construction

4000 V

Fine strands of bare copper wire, PVC core insulation.


Core colours acc. to DIN VDE 0293, cores or more
with green/yellow protective conductor in the outer
layer. Cores twisted in layers. PVC outer sheath,
flame retardant and self-extinguishing (acc. to DIN
VDE 0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour yellow (RAL 1016).

Conductor stranding:

Part-No.

No. of cores
+
crosssection

Copper
weight

09 0015 003
09 0015 004
09 0015 005
09 0025 003
09 0025 004
09 0025 005

Rated voltage:
300/500 V

Test voltage:

fine copper strands


acc. to DINVDE 0295, class 5

Insulation resistance:
min. 20 MOhm X km

Temperature range:

Weight

kg/km

Outer
diameter
approx.
mm

3 G 1,5
4 G 1,5
5 G 1,5

43,0
58,0
72,0

7,8
8,5
9,7

95
117
144

fixed installation: 4 X cable diameter


flexible application: 15 X cable diameter

3 G 2.5
4 G 2.5
5 G 2.5

72,0
96,0
120,0

9,7
10,4
11,7

152
205
225

acc. to DIN VDE 0245, 0250, 0281

kg/km

fixed installation:
flexible application:

-40C to +80C
-5C to +70C

Bending radius:

Approvals:

ConCab kabel connects the world

191

CC-control cable black-JZ-586


Numbered black cores 0,6/1kV
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 586 25G1,5 JZ 0,6/1 kV

The flexible CC-control cable black PVC-JZ-586


0,6/1 kV is suitable for control, regulating and
measuring cables especially when free and
unrestricted movement is required. It is applied in
machine tools, plant and appliance construction,
heating, air conditioning and ventilation technology
as well as for other applications in electrical
equipment. These cables are applied for greater rated
voltage and if a black sheath is stipulated. The cable is
mainly sold in non-European countries. The outer
sheath, based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone, cadmium and free of
harmful substances.

Technical data
Rated voltage:
0,6/1 kV
Test voltage:
3500 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core insulation,
black cores with consecutive white numbering.
Control cables with 3 cores or more with
green/yellow protective conductor in the outer layer.
Cores twisted in layers. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).

192

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

586 0010 002 01


586 0010 003 01
586 0010 003 02
586 0010 004 01
586 0010 004 02
586 0010 005 01
586 0010 005 02
586 0010 007 01
586 0010 007 02
586 0010 012 01
586 0010 012 02
586 0010 018 01
586 0010 018 02
586 0010 025 01
586 0010 034 01
586 0010 041 01
586 0010 042 01
586 0010 050 01

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
5 X 1,0
7 G 1,0
7 X 1,0
12 G 1,0
12 X 1,0
18 G 1,0
18 X 1,0
25 G 1,0
34 G 1,0
41 G 1,0
42 G 1,0
50 G 1,0

19,2
29,0
witho.gnye
38,4
witho.gnye
48,8
witho.gnye
67,0
witho.gnye
115,0
witho.gnye
173,0
witho.gnye
240,0
326,0
394,0
403,0
480,0

8,6
9,0
9,0
9,6
9,6
10,4
10,4
11,1
11,1
14,0
14,0
16,1
16,1
18,6
21,3
23,2
25,6
26,8

80
90
90
100
100
130
130
170
170
290
290
405
405
570
750
890
900
1100

586 0015 002 01


586 0015 003 01
586 0015 003 02
586 0015 004 01
586 0015 004 02
586 0015 005 01
586 0015 005 02
586 0015 007 01
586 0015 007 02
586 0015 012 01
586 0015 012 02
586 0015 018 01
586 0015 025 01
586 0015 034 01
586 0015 042 01
586 0015 050 01

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
7 G 1,5
7 X 1,5
12 G 1,5
12 X 1,5
18 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5

29,0
43,0
witho.gnye
58,0
witho.gnye
72,0
witho.gnye
101,0
witho.gnye
173,0
witho.gnye
259,0
360,0
490,0
605,0
720,0

9,6
10,1
10,1
10,8
10,8
11,7
11,7
12,6
12,6
16,1
16,1
18,8
21,7
24,9
29,5
29,8

95
110
110
141
141
170
170
225
225
370
370
520
730
950
1120
1400

586 0025 002 01 2 X 2.5


586 0025 003 01 3 G 2.5
586 0025 003 02 3 X 2.5
586 0025 004 01 4 G 2.5
586 0025 004 02 4 X 2.5
586 0025 005 01 5 G 2.5
586 0025 005 02 5 X 2.5
586 0025 007 01 7 G 2.5
586 0025 007 02 7 X 2.5
586 0025 012 01 12 G 2.5
586 0025 018 01 18 G 2.5
586 0025 025 01 25 G 2.5

48,0
72,0
witho.gnye
96,0
witho.gnye
120,0
witho.gnye
168,0
witho.gnye
288,0
432,0
600,0

10,8
11,3
11,3
12,2
12,2
13,3
13,3
14,4
14,4
18,7
22,0
25,8

160
175
175
203
203
251
251
330
330
553
795
1110

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

586 0040 002 01


586 0040 003 01
586 0040 004 01
586 0040 005 01
586 0040 007 01

2X4
3G4
4G4
5G4
7G4

77,0
115,0
154,0
192,0
269,0

12,1
12,7
13,8
15,1
16,4

180
230
310
410
540

586 0060 003 01


586 0060 004 01
586 0060 005 01
586 0060 007 01

3G6
4G6
5G6
7G6

173,0
230,0
288,0
403,0

13,9
15,1
16,8
18,2

370
430
650
860

586 0100 003 01


586 0100 004 01
586 0100 005 01
586 0100 007 01

3 G 10
4 G 10
5 G 10
7 G 10

288,0
384,0
480,0
672,0

17,1
18,7
20,7
22,8

660
790
960
1300

586 0160 003 01


586 0160 004 01
586 0160 005 01
586 0160 007 01

3 G 16
4 G 16
5 G 16
7 G 16

461,0
614,0
768,0
1075,0

19,3
21,3
23,6
26,2

700
1100
1600
1890

586 0250 003 01


586 0250 004 01
586 0250 005 01
586 0250 007 01

3 G 25
4 G 25
5 G 25
7 G 25

720,0
960,0
1200,0
1680,0

23,9
26,2
29,0
31,9

1450
1600
2050
2900

586 0350 003 01


586 0350 004 01
586 0350 005 01

3 G 35
4 G 35
5 G 35

1008,0
1344,0
1680,0

26,6
29,1
32,5

1900
2400
2900

586 0500 003 01


586 0500 004 01

3 G 50
4 G 50

1440,0
1920,0

32,1
35,6

2700
3400

586 0700 003 01


586 0700 004 01

3 G 70
4 G 70

2016,0
2688,0

36,9
40,7

3300
5050

586 0950 003 01


586 0950 004 01

3 G 95
4 G 95

2688,0
3648,0

41,1
46,8

4400
6010

586 1200 004 01

4 G 120

4608,0

53,5

7500

ConCab kabel connects the world

193

194

195

CC-control cable-JZ-CY-130
Numbered black cores, shielded
Conforms to the EC low voltage guideline 73/23/EEC .

ConCab kabel Mainhardt 130 12G1,5 JZ-CY

The flexible shielded CC-control cable


PVC-JZ-CY-130 is suitable as control and
connection cable. It is applied in machine tools,
plant and appliance construction,
heating, air conditioning and ventilation
technology as well as for other applications in
electrical equipment especially where a greater
electromagnetic compatibility is required.
The outer sheath, based on PVC, is extremely
resistant to oil and chemicals. It is free of
silicone, cadmium and free of harmful
substances.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5

Construction

Insulation resistance:
min. 20 MOhm X km

Fine strands of bare copper wire,


PVC core insulation. Cores black with
consecutive white numbering. 3 cores or more with
green/yellow protective conductor in the outer layer.
Cores twisted in layers.
PVC inner sheath (colour grey). Overall tinned
copper shield. PVC outer sheath, flame retardant and
self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour transparent.

196

Technical data
Rated voltage:
300/500 V
Test voltage:
4000 V

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg/km

130 0005 002


130 0005 003
132 0005 003
130 0005 004
132 0005 004
130 0005 005
130 0005 007
130 0005 012
130 0005 014
130 0005 018
130 0005 021
130 0005 025
130 0005 030
130 0005 040
130 0005 050

2 X 0,5
41,0
3 G 0,5
46,0
3 X 0,5 witho. gnye
4 G 0,5
55,0
4 X 0,5 witho. gnye
5 G 0,5
66,0
7 G 0,5
84,0
12 G 0,5
139,0
14 G 0,5
147,0
18 G 0,5
186,0
21 G 0,5
211,0
25 G 0,5
250,0
30 G 0,5
297,0
40 G 0,5
343,0
50 G 0,5
407,0

6,8
7,3
7,3
7,8
7,8
8,5
9,1
11,5
12,0
13,3
14,2
15,4
16,1
18,4
21,6

92
102
102
113
113
127
157
215
223
335
340
403
468
572
726

130 0007 002


130 0007 003
132 0007 003
130 0007 004
132 0007 004
130 0007 005
130 0007 007
130 0007 012
130 0007 018
130 0007 025
130 0007 034
130 0007 040
130 0007 042
130 0007 050

2 X 0,75
46,0
3 G 0,75
58,0
3 X 0,75 witho. gnye
4 G 0,75
64,0
4 X 0,75 witho. gnye
5 G 0,75
77,0
7 G 0,75
102,0
12 G 0,75
177,0
18 G 0,75
243,0
25 G 0,75
308,0
34 G 0,75
323,4
40 G 0,75
369,0
42 G 0,75
500,0
50 G 0,75
543,0

7,4
7,8
7,8
8,4
8,4
9,0
9,8
12,3
14,4
16,9
19,1
21,0
22,0
23,3

101
116
116
132
132
156
182
265
391
465
601
735
750
815

130 0010 002


130 0010 003
132 0010 003
130 0010 004
132 0010 004
130 0010 005
130 0010 007
130 0010 012
130 0010 018
130 0010 025
130 0010 034
130 0010 041
130 0010 050

2 X 1,0
56,0
3 G 1,0
65,0
3 X 1,0 witho. gnye
4 G 1,0
78,0
4 X 1,0 witho. gnye
5 G 1,0
89,0
7 G 1,0
113,0
12 G 1,0
194,0
18 G 1,0
286,0
25 G 1,0
389,0
34 G 1,0
505,0
41 G 1,0
578,0
50 G 1,0
688,0

7,9
8,2
8,2
8,7
8,7
9,6
10,4
13,3
15,5
17,9
20,6
22,0
24,0

98
135
135
155
155
181
203
347
478
645
865
1010
1172

Part-No.

No. of cores
+
crosssection

130 0015 002


130 0015 003
132 0015 003
130 0015 004
132 0015 004
130 0015 005
130 0015 007
130 0015 012
130 0015 018
130 0015 025
130 0015 034
130 0015 050
130 0015 061

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
50 G 1,5
61 G 1,5

65,0
83,0
witho. gnye
118,0
witho. gnye
125,0
196,0
280,0
389,0
535,0
702,0
1006,0
1176,0

8,5
9,0
9,0
10,0
10,0
10,5
11,4
15,0
17,3
20,1
23,0
27,1
30,0

141
164
164
188
188
221
266
438
625
889
1114
1648
1710

130 0025 002


130 0025 003
130 0025 004
130 0025 005
130 0025 007
130 0025 012
130 0025 018

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
18 G 2.5

112,0
146,0
176,0
211,0
288,0
478,0
598,0

9,9
10,3
11,2
12,7
13,8
17,8
21,5

202
213
256
304
420
660
945

130 0040 004


130 0040 005

4G4
5G4

290,0
318,0

13,4
14,7

410
480

130 0060 004


130 0060 005
130 0060 007

4G6
5G6
7G6

360,0
441,0
530,0

15,9
17,3
18,3

532
656
798

130 0100 004


130 0100 005

4 G 10
5 G 10

558,0
714,0

19,0
22,5

930
1080

130 0160 004


130 0160 005

4 G 16
5 G 16

804,0
1050,0

22,2
24,9

1190
1385

130 0250 004

4 G 25

1310,0

32,4

1910

130 0350 004

4 G 35

1618,0

35,4

2510

130 0500 004

4 G 50

2250,0

38,5

3370

130 0700 004

4 G 70

3090,0

43,7

3815

130 0950 004

4 G 95

4050,0

49,8

5856

130 1200 004

4 G 120

5234,0

58,1

7245

ConCab kabel connects the world

Copper Outer dia- Weight


weight
meter
approx.
kg/km
mm
kg / km

197

CC-control cable-JB-CY-131
Coloured cores, shielded
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 131 5G1,5 JB-CY

The flexible shielded CC-control cable


PVC-JB-CY-131, is suitable as a control and
connection cable. It is applied in machine tools, plant
and appliance construction, heating, air
conditioning and ventilation technology as well as for
other applications in electrical equipment especially
where a greater electromagnetic compatibility is
required. The outer sheath, based on PVC, is
extremely resistant to oil and chemicals. It is free of
silicone, cadmium and free of harmful substances.

Technical data
Rated voltage:
300/500 V
Test voltage:
4000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295 class 5

Construction
Fine strands of bare copper wire
with PVC core insulation.
Core colours acc. to DIN VDE 0293, part308.
3 cores or more with green/yellow protective
conductor in the outer layer.
Cores twisted in layers. PVC inner sheath (colour
grey), overall tinned copper shield.
PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Colour transparent.

198

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

131 0005 002


131 0005 003
131 0005 004
131 0005 005

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

41,0
46,0
55,0
66,0

6,8
7,3
7,8
8,5

92
102
113
127

131 0007 002


131 0007 003
131 0007 004
131 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

46,0
58,0
64,0
77,0

7,4
7,8
8,4
9,0

101
116
132
156

131 0010 002


131 0010 003
131 0010 004
131 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

56,0
65,0
78,0
89,0

7,8
8,2
8,7
9,6

119
135
155
181

131 0015 002


131 0015 003
131 0015 004
131 0015 005

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

65,0
83,0
118,0
125,0

8,5
9,0
10,0
10,5

141
164
188
221

131 0025 003


131 0025 004
131 0025 005

3 G 2.5
4 G 2.5
5 G 2.5

146,0
176,0
211,0

10,3
11,2
12,7

213
256
304

131 0040 004


131 0040 005

4G4
5G4

290,0
318,0

13,4
14,7

410
480

131 0060 004


131 0060 005

4G6
5G6

360.0
441,0

15,9
17,3

532
656

131 0100 004


131 0100 005

4 G 10
5 G 10

558,0
714,0

19,0
22,5

930
1080

131 0160 004


131 0160 005

4 G 16
5 G 16

804,0
1050,0

22,2
24,9

1190
1385

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

131 0250 004


131 0250 005

4 G 25
5 G 25

1310,0
1476,0

32,4
33,0

1910
2295

131 0350 004


131 0350 005

4 G 35
5 G 35

1618,0
1984,0

35,4
36,5

2510
2805

131 0500 004

4 G 50

2250,0

38,5

3370

131 0700 004

4 G 70

3090,0

43,7

3815

131 0950 004

4 G 95

4050,0

53,7

5856

131 1200 004

4 G 120

5234,0

58,1

7245

131 1500 004

4 G 150

6246,0

63,7

8440

131 1850 004

4 G 185

7615,0

66,8

10880

ConCab kabel connects the world

199

CC-control cable blue-OZ-CY-127


For intrinsically safe electric circuits, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 127 3x1,5 OZ-CY

Technical data
The CC-control cable blue-OZ-CY-127 shielded,
conforms to VDE 0165, section 12.2.2 and is
suitable as a control, regulating and measuring cable.
These cables for intrinsically safe circuits are
assembled with the ignition protection i acc.
to DIN VDE. For individual special application
stipulations refer to DIN VDE 0165. The overall
shield protects data transfer. The outer sheath, based
on PVC, is extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free of
harmful substances.

Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire
with PVC core insulation.
Black cores with consecutive
white numbering. Cores twisted in layers, foil
wrapping, overall tinned copper shield, PVC outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour blue (RAL 5015).

200

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter
Approvals:
acc. to DIN VDE 0245, 250, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

127 0007 002


127 0007 003
127 0007 004
127 0007 005
127 0007 007
127 0007 008
127 0007 012
127 0007 020
127 0007 025

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
12 X 0,75
20 X 0,75
25 X 0,75

38,0
49,0
58,0
70,0
100,0
123,0
154,0
220,0
260,0

5,7
6,3
6,7
7,3
8,6
9,5
10,3
12,9
15,1

56
70
95
130
168
220
232
364
454

127 0010 002


127 0010 003
127 0010 004
127 0010 005
127 0010 007
127 0010 012
127 0010 018
127 0010 025

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
7 X 1,0
12 X 1,0
18 X 1,0
25 X 1,0

55,0
70,0
80,0
95,0
120,0
185,0
286,0
340,0

6,0
6,4
7,2
7,6
9,0
11,2
13,3
16,2

84
110
130
156
192
265
480
517

127 0015 002


127 0015 003
127 0015 004
127 0015 005
127 0015 007
127 0015 012
127 0015 018
127 0015 025

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
7 X 1,5
12 X 1,5
18 X 1,5
25 X 1,5

65,0
90,0
110,0
125,0
159,0
245,0
373,0
485,0

6,8
7,4
8,1
8,9
10,6
12,7
15,2
18,5

97
125
165
193
245
365
625
730

kg/km

ConCab kabel connects the world

201

CC-control cable black-JZ-CY-136


Numbered black cores 0,6/1kV, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 136 12G1,5 JZ-CY 0,6/1 kV

The flexible CC-control cable black-JZ-CY-136


shielded is suitable as a control, regulating and
measuring cable especially for free, unrestricted
movement. It can be used in machine tools, plant
and apparatus construction, heating, air
conditioning and ventilation technology as well as
in other applications in electrical equipment.
The cable is used when a greater
electromagnetic compatibility and black
outer sheath are required.
The outer sheath, based on PVC, is extremely
resistant to oil and chemicals. It is free of silicone,
cadmium and free of harmful substances.

Construction
Fine strands of bare copper wire
with PVC core insulation.
Cores black with consecutive white numbering.
3 cores or more with protective green/yellow
conductor in the outer layer. Cores twisted in
layers. PVC inner sheath, overall tinned copper
shield, PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour black (RAL 9005).

202

Technical data
Rated voltage:
0,6/1 kV
Test voltage:
3500 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Insulation resistance:
min. 20 MOhm X km
Bending radius:
fixed installation: 10 X cable diameter
flexible application: 20 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

136 0010 002


136 0010 003
136 0010 004
136 0010 005
136 0010 007
136 0010 012
136 0010 018
136 0010 025

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

52,0
66,0
79,0
93,0
117,0
204,0
280,0
369,0

10,8
11,2
11,8
12,6
13,3
16,4
18,7
21,6

198
228
261
300
335
522
687
884

136 0015 002


136 0015 003
136 0015 004
136 0015 005
136 0015 007
136 0015 012
136 0015 018
136 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

69,0
87,0
102,0
125,0
180,0
281,0
391,0
518,0

11,8
12,3
13,0
13,9
15,0
18,7
21,8
25,1

243
273
290
352
448
690
938
1180

136 0025 002


136 0025 003
136 0025 004
136 0025 005
136 0025 007
136 0025 012
136 0025 018
136 0025 025

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
18 G 2.5
25 G 2.5

101,4
123,0
168,0
204,0
265,0
421,0
573,1
683,0

11,5
13,5
14,6
15,7
17,0
21,7
26,1
31,9

316
354
413
515
619
936
1177
1547

136 0040 002


136 0040 003
136 0040 004
136 0040 005
136 0040 007
136 0040 012

2X4
3G4
4G4
5G4
7G4
12 G 4

152,0
199,0
238,0
302,0
396,0
742,1

14,3
15,1
16,2
17,7
19,0
26,9

418
488
587
689
828
1283

136 0060 002


136 0060 003
136 0060 004
136 0060 005
136 0060 007

2X6
3G6
4G6
5G6
7G6

203,0
274,0
318,0
419,0
559,0

16,0
17,0
17,7
19,2
21,2

523
609
715
862
1105

Part-No.

No. of cores
+
crosssection

Copper
weight

136 0100 002


136 0100 003
136 0100 004
136 0100 005
136 0100 007

2 X 10
3 G 10
4 G 10
5 G 10
7 G 10

308,0
421,0
574,0
612,0
889,0

18,4
19,6
21,7
23,0
26,8

751
891
1188
1320
1654

136 0160 002


136 0160 003
136 0160 004
136 0160 005
136 0160 007

2 X 16
3 G 16
4 G 16
5 G 16
7 G 16

450,0
631,0
809,0
935,0
1362,0

22,0
23,5
24,3
26,7
31,9

984
1222
1656
1740
2308

136 0250 003


136 0250 004
136 0250 005
136 0250 007

3 G 25
4 G 25
5 G 25
7 G 25

949,0
1165,0
1400,0
2268,8

28,0
29,8
31,6
39,8

1836
2179
2590
3835

136 0350 003


136 0350 004
136 0350 005

3 G 35
4 G 35
5 G 35

1290,0
1638,0
2081,0

32,7
32,7
42,7

2353
2893
3554

136 0500 003


136 0500 004
136 0500 005

3 G 50
4 G 50
5 G 50

1807,0
2368,0
2931,0

39,2
39,6
46,7

3266
4094
5003

136 0700 003


136 0700 004
136 0700 005

3 G 70
4 G 70
5 G 70

2481,0
3261,0
4285,0

44,8
44,5
54,5

4387
5467
6573

136 0950 003


136 0950 004
136 0950 005

3 G 95
4 G 95
5 G 95

3625,0
4055,0
6042,0

50,0
51,0
62,5

5580
5849
8970

136 1200 003


136 1200 004

3 G 120
4 G 120

4653,0
5225,0

54,8
58,1

7773
7509

kg/km

ConCab kabel connects the world

kg/km

Outer
diameter
approx.
mm

Weight
kg/km

203

CC-control cable-JZ-SY-120
Numbered black cores with steel wire braiding
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 120 12G1,5 JZ-SY

The flexible CC-control cable-JZ-SY-120 with steel


wire braiding, is suitable as a control, regulating and
measuring cable especially for free, unrestricted
movement. It is used in machine tool, plant and
apparatus construction, heating, air
conditioning and ventilation technology as well as for
other applications in electrical equipment. On account
of its triple protection with an inside sheath, steel wire
braiding and outer sheath, it is particulary suitable for
heavy mechanical work applications. The outer
sheath, based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone, cadmium and free of
harmful substances.

Technical data
Rated voltage:
300/500 V
Test voltage:
4000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core insulation,
cores black with consecutive
white numbering. 3 cores or more with
protective green/yellow conductor in the outer layer.
Cores twisted in layers. PVC inner sheath, overall
steel wire braiding, PVC outer sheath, flame retardant
and self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1
and IEC 60332-1). Colour transparent.

204

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

120 0005 002


120 0005 003
120 0005 004
120 0005 005
120 0005 007
120 0005 010
120 0005 012
120 0005 014
120 0005 018
120 0005 021
120 0005 025
120 0005 040
120 0005 052
120 0005 061

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
10 G 0,5
12 G 0,5
14 G 0,5
18 G 0,5
21 G 0,5
25 G 0,5
40 G 0,5
52 G 0,5
61 G 0,5

9,6
14,4
19,2
24,0
34,0
48,0
58,0
68,0
86,4
101,0
120.0
192,0
250,0
293,0

7,6
8,0
8,5
9,2
10,0
11,7
11,9
12,6
13,9
14,9
15,7
18,9
20,9
21,9

95
105
115
140
170
190
210
230
280
310
370
500
640
730

120 0007 002


120 0007 003
120 0007 004
120 0007 005
120 0007 007
120 0007 009
120 0007 012
120 0007 018
120 0007 021
120 0007 025
120 0007 034
120 0007 042
120 0007 050
120 0007 061
120 0007 065

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
9 G 0,75
12 G 0,75
18 G 0,75
21 G 0,75
25 G 0,75
34 G 0,75
42 G 0,75
50 G 0,75
61 G 0,75
65 G 0,75

14,4
21,6
29,0
36,0
50,0
65,0
86,0
130,0
151,0
180,0
245,0
303,0
360,0
439,0
468,0

8,1
8,5
9,4
10,0
11,3
12,4
12,9
15,0
16,2
17,2
19,3
20,8
23,0
23,9
25,7

100
120
140
150
180
215
250
350
390
440
550
635
780
920
976

19,2
29,0
38,4
48,0
67,2
77,0
115,0
134,0
173,0
192,0
240.0
326,0
346,0
394,0
404,0
480,0
586,0
624,0
960,0

8,7
8,8
9,5
10,1
11,1
12,5
13,9
14,5
15,9
16,7
18,0
20,5
20,7
22,3
23,0
24,3
25,9
27,4
32,4

110
130
150
170
210
240
290
350
410
440
540
690
735
790
805
950
1150
1245
1870

120 0010 002


2 X 1,0
120 0010 003
3 G 1,0
120 0010 004
4 G 1,0
120 0010 005
5 G 1,0
120 0010 007
7 G 1,0
120 0010 008
8 G 1,0
120 0010 012 12 G 1,0
120 0010 014 14 G 1,0
120 0010 018 18 G 1,0
120 0010 020 20 G 1,0
120 0010 025 25 G 1,0
120 0010 034 34 G 1,0
120 0010 036 36 G 1,0
120 0010 041 41 G 1,0
120 0010 042 42 G 1,0
120 0010 050 50 G 1,0
120 0010 061 61 G 1,0
120 0010 065 65 G 1,0
120 0010 100 100 G 1,0

Weight

Part-No.

kg/km

No. of cores
+
crosssection

120 0015 002


2 X 1,5
120 0015 003
3 G 1,5
120 0015 004
4 G 1,5
120 0015 005
5 G 1,5
120 0015 007
7 G 1,5
120 0015 008
8 G 1,5
120 0015 012 12 G 1,5
120 0015 014 14 G 1,5
120 0015 018 18 G 1,5
120 0015 021 21 G 1,5
120 0015 025 25 G 1,5
120 0015 034 34 G 1,5
120 0015 042 42 G 1,5
120 0015 050 50 G 1,5
120 0015 061 61 G 1,5
120 0015 080 80 G 1,5
120 0015 100 100 G 1,5

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

29,0
43,0
58,0
72,0
101,0
115,0
173,0
202,0
259,0
302,0
360,0
490,0
605,0
720,0
878,0
1152,0
1440,0

9,3
9,8
10,2
11,3
12,0
14,2
15,5
15,8
17,7
19,5
20,4
23,1
24,4
27,2
29,5
33,0
35,7

130
150
180
230
270
290
400
460
530
600
700
940
1120
1300
1550
1950
2350

kg/km

120 0025 002


120 0025 003
120 0025 004
120 0025 005
120 0025 007
120 0025 012
120 0025 018
120 0025 025
120 0025 034

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
18 G 2.5
25 G 2.5
34 G 2.5

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
816,0

10,4
11,2
12,0
13,2
14,2
18,4
21,5
24,4
28,1

200
230
290
310
380
550
810
1100
1450

120 0040 003


120 0040 004
120 0040 005
120 0040 007

3G4
4G4
5G4
7G4

115,2
154,0
192,0
269,0

12,1
14,2
15,0
16,4

270
340
420
540

120 0060 004


120 0060 005
120 0060 007

4G6
5G6
7G6

230,0
288,0
403,0

16,3
17,7
19,3

520
600
780

120 0100 004


120 0100 005
120 0100 007

4 G 10
5 G 10
7 G 10

384,0
480,0
672,0

19,5
21,6
23,4

800
930
1146

120 0160 004


120 0160 005
120 0160 007

4 G 16
5 G 16
7 G 16

614,0
768,0
1075,0

22,5
24,7
27,3

1230
1450
1670

120 0250 004


120 0250 005

4 G 25
5 G 25

960,0
1200,0

28,9
32,2

1600
1950

120 0350 004


120 0350 005

4 G 35
5 G 35

1344,0
1680,0

33,7
37,8

2250
2700

205

CC-control cable-JB-SY-121
Coloured cores with steel wire braiding
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 121 5G1,5 JB-SY

The flexible CC-control cable-JB-SY-121 with steel


wire braiding, is suitable as a control,
regulating and measuring cable especially for free,
unrestricted movement. It is used in machine tool,
plant and apparatus construction, heating, air
conditioning and ventilation technology as well as for
other applications in electrical equipment. On account
of its triple protection with an inside sheath, steel wire
braiding and an outer sheath, it is particulary suitable
for heavy mechanical work. The outer sheath, based
on PVC, is extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free
of harmful substances.

Technical data
Rated voltage:
300/500 V
Test voltage:
4000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire,
PVC core insulation. Cores coloured acc.
to DIN VDE 0293, part 308.
3 cores or more with protective
green/yellow conductor in the outer layer.
Cores twisted in layers. PVC inner sheath, overall
steel wire braiding, PVC outer sheath, flame retardant
and self- extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour transparent.

206

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
6 X cable diameter
20 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0245, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

121 0005 002


121 0005 003
121 0005 004
121 0005 005

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

9,6
14,4
19,2
24,0

7,7
8,1
8,6
9,2

114
123
138
154

121 0007 002


121 0007 003
121 0007 004
121 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
29,0
36,0

8,1
8,5
9,4
9,9

126
143
155
185

121 0010 002


121 0010 003
121 0010 004
121 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,2
29,0
38,4
48,0

8,7
8,8
9,6
10,2

145
163
184
212

121 0015 002


121 0015 003
121 0015 004
121 0015 005

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

29,0
43,0
58,0
72,0

9,3
9,8
10,2
11,2

170
190
221
265

kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

121 0025 002


121 0025 003
121 0025 004
121 0025 005

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5

48,0
72,0
96,0
120,0

12,1
12,6
13,9
15,2

185
280
335
430

121 0040 003


121 0040 004
121 0040 005

3G4
4G4
5G4

115,2
154,0
192,0

14,6
15,7
17,3

349
460
550

121 0060 003


121 0060 004
121 0060 005

3G6
4G6
5G6

173,0
230,0
288,0

15,8
17,3
18,8

452
595
673

121 0100 004


121 0100 005

4 G 10
5 G 10

384,0
480,0

21,1
23,1

982
1136

121 0160 004


121 0160 005

4 G 16
5 G 16

614,0
768,0

23,8
26,7

1350
1650

121 0250 004


121 0250 005

4 G 25
5 G 25

960,0
1200,0

29,2
32,4

2000
2400

121 0350 004


121 0350 005

4 G 35
5 G 35

1344,0
1680,0

32,5
36,3

2060
3000

121 0500 004

4 G 50

1920,0

38,5

2943

121 0700 004

4 G 70

2688,0

43,5

4092

121 0950 004

4 G 95

3648,0

49,7

6300

121 1200 004

4 G 120

4608,0

56,9

7250

kg/km

ConCab kabel connects the world

Weight
kg/km

207

208

209

CC-control cable H05VV5-F-115


Oil resistant PVC-control cable according to HD 21.13 S1
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 115 4G1,5 H05VV5-F <HAR>

Technical data
The flexible CC-control cable
H05VV5-F-115, is suitable as a control,
regulating and measuring cable for free
unrestricted movement. It is used in machine tool,
plant and apparatus construction, heating, air
conditioning and ventilation technology as well
as in other oil resistant stipulated
applications acc. to DIN VDE 0281, part 13 resp.
HD 21.13 S1. The outer sheath, based on PVC, is
extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free
of harmful substances.

Construction
Fine strands of bare copper wire with PVC core
insulation. Cores black with consecutive
white numbering. 3 cores or more with
protective green/yellow conductor in the outer
layer. Cores twisted in layers. Oil resistant PVC
outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7001).

210

Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
Temperature range:
fixed installation:
-40C to +70C
flexible application:
-5C to +70C
Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, part 13
HD 21.13 S1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

115 0005 002


115 0005 003
115 0005 004
115 0005 005
115 0005 007

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5

9,7
14,4
20,5
24,0
34,0

5,9
6,2
7,0
7,4
9,3

46
54
65
80
119

115 0005 012


115 0005 014
115 0005 018
115 0005 025
115 0005 027
115 0005 034
115 0005 041
115 0005 050
115 0005 061
115 0005 065

12 G 0,5
14 G 0,5
18 G 0,5
25 G 0,5
27 G 0,5
34 G 0,5
41 G 0,5
50 G 0,5
61 G 0,5
65 G 0,5

58,0
67,0
86,6
120,0
129,6
163,2
196,0
240,0
293,0
313,0

11,4
12,5
13,4
16,2
16,7
19,5
21,0
22,5
24,0
26,3

186
215
260
349
373
480
570
658
780
810

kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

115 0010 014


115 0010 018
115 0010 025
115 0010 027
115 0010 034
115 0010 041
115 0010 042
115 0010 050
115 0010 061
115 0010 065

14 G 1,0
18 G 1,0
25 G 1,0
27 G 1,0
34 G 1,0
41 G 1,0
42 G 1,0
50 G 1,0
61 G 1,0
65 G 1,0

134,0
173,0
240,0
259,0
326,0
392,0
402,0
480,0
586,0
624,0

14,5
15,5
18,4
18,4
20,9
22,7
22,7
23,8
25,9
27,7

361
400
569
582
742
822
837
1052
1265
1315

115 0015 002


115 0015 003
115 0015 004
115 0015 005
115 0015 007

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5

29,0
43,0
58,0
72,0
101,0

7,7
8,6
9,3
10,3
12,0

90
97
128
168
243

115 0015 012


115 0015 014
115 0015 018
115 0015 025
115 0015 027
115 0015 034
115 0015 041
115 0015 042
115 0015 050
115 0015 061
115 0015 065

12 G 1,5
14 G 1,5
18 G 1,5
25 G 1,5
27 G 1,5
34 G 1,5
41 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5

173,0
202,0
259,0
360,0
389,0
490,0
590,0
605,0
720,0
878,0
936,0

14,6
16,0
17,6
21,8
21,8
26,0
26,4
27,0
28,5
30,7
32,8

324
372
485
671
695
881
1085
1110
1381
1640
1730

115 0025 002


115 0025 003
115 0025 004
115 0025 005
115 0025 007
115 0025 012
115 0025 014
115 0025 018
115 0025 025
115 0025 034
115 0025 041
115 0025 050

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
14 G 2.5
18 G 2.5
25 G 2.5
34 G 2.5
41 G 2.5
50 G 2.5

48,0
72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0
816,0
984,0
1200,0

9,0
9,7
10,8
11,9
14,7
17,8
19,6
21,4
26,1
29,5
32,6
35,0

110
154
212
242
350
543
611
787
1175
1529
1905
2290

kg/km

115 0007 002


115 0007 003
115 0007 004
115 0007 005
115 0007 007

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75

14,4
21,6
29,0
36,0
50,0

6,3
6,8
7,5
8,3
10,1

52
75
82
113
145

115 0007 012


115 0007 014
115 0007 018
115 0007 025
115 0007 034
115 0007 041
115 0007 050
115 0007 061
115 0007 065

12 G 0,75
14 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75
50 G 0,75
61 G 0,75
65 G 0,75

86,0
101,0
130,0
180,0
245,0
296,0
360,0
439,0
468,1

12,2
13,2
14,3
17,7
19,8
21,5
23,3
25,8
26,1

231
274
338
461
614
730
850
1030
1071

115 0010 002


115 0010 003
115 0010 004
115 0010 005
115 0010 007

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0

19,2
29,0
38,4
48,0
67,0

6,8
7,2
7,8
8,8
10,4

66
78
104
132
183

115 0010 012

12 G 1,0

115,0

13,0

286

ConCab kabel connects the world

kg / km

211

CC-control cable H05VVC4V5-K-116


Oil resistant PVC-control cable according to HD 21.13 S1, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 116 25G1,5 H05VVC4V5-K <HAR>

The flexible CC-control cable shielded


H05VVC4V5-K-116 is suitable as a control,
regulating and measuring cable especially when free
unrestricted movement is required. It is used in
machine tool, plant and apparatus
construction, heating, air conditioning and ventilation
technology and where a greater electromagnetic
compatibility (EMC) as well as stipulations for oil
resistance under DIN VDE 0281, part 13 resp.
HD 21.13 S1 are required. The outer sheath, based on
PVC, is extremely resistant to oil and chemicals. It is
free of silicone, cadmium and free of harmful
substances.

Technical data
Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire with PVC core
insulation, cores black with consecutive white
numbering. 3 cores or more with protective
green/yellow conductor in the outer layer.
Cores twisted in layers. PVC inner sheath,
overall tinned copper shield, oil resistant
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

212

fixed installation:
flexible application:

Temperature range:
-40C to +70C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, part 13
HD 21.13 S1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

116 0010 018


116 0010 025
116 0010 034
116 0010 041
116 0010 042
116 0010 050
116 0010 061
116 0010 065

18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
42 G 1,0
50 G 1,0
61 G 1,0
65 G 1,0

304,0
370,0
420,0
578,0
588,0
728,0
883,0
914,0

18,9
22,4
25,1
26,1
26,1
28,5
30,1
32,4

580
766
996
1155
1175
1300
1500
1510

116 0015 002


116 0015 003
116 0015 004
116 0015 005
116 0015 007
116 0015 012
116 0015 014
116 0015 018
116 0015 025
116 0015 034
116 0015 041
116 0015 042
116 0015 050
116 0015 061
116 0015 065

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
14 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5

69,0
83,0
95,0
118,0
170,0
240,0
283,0
355,0
498,0
754,0
805,0
820,0
1033,0
1238,0
1296,0

9,9
10,9
11,9
13,2
15,7
18,7
18,3
21,8
26,8
29,5
30,7
30,7
34,0
36,5
38,1

146
176
235
245
314
500
560
657
950
1204
1453
1468
1663
1852
1971

116 0025 002


116 0025 003
116 0025 004
116 0025 005
116 0025 007
116 0025 012
116 0025 014
116 0025 018
116 0025 025
116 0025 034
116 0025 041
116 0025 050
116 0025 061

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
14 G 2.5
18 G 2.5
25 G 2.5
34 G 2.5
41 G 2.5
50 G 2.5
61 G 2.5

81,0
110,0
143,0
182,0
267,0
409,0
425,0
608,0
897,0
1179,0
1473,0
1660,0
1992,0

12,0
12,6
14,0
15,5
18,4
20,6
22,5
24,3
31,3
35,0
36,0
38,5
42,0

190
243
280
342
439
670
890
1052
1375
1892
2286
2673
3085

kg/km

116 0005 002


116 0005 003
116 0005 004
116 0005 005
116 0005 007
116 0005 012
116 0005 014
116 0005 018
116 0005 025
116 0005 034
116 0005 041
116 0005 050
116 0005 061
116 0005 065

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
14 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
41 G 0,5
50 G 0,5
61 G 0,5
65 G 0,5

30,0
36,0
42,0
48,0
64,0
105,0
114,0
147,0
210,0
298,0
349,0
470,0
530,0
563,0

8,6
9,0
9,6
10,4
12,1
13,5
14,2
15,8
20,0
22,4
23,0
25,0
26,8
28,4

92
109
126
156
192
280
302
384
556
634
770
970
1072
1198

116 0007 002


116 0007 003
116 0007 004
116 0007 005
116 0007 007
116 0007 012
116 0007 014
116 0007 018
116 0007 025
116 0007 034
116 0007 041
116 0007 050
116 0007 061
116 0007 065

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
14 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75
50 G 0,75
61 G 0,75
65 G 0,75

41,0
55,0
67,0
78,0
90,0
166,0
175,0
190,0
275,0
400,0
470,0
582,0
679,0
708,0

9,0
9,3
10,2
10,9
12,9
14,3
15,1
16,9
21,5
23,7
24,5
26,8
29,4
31,2

102
115
150
189
235
355
362
488
654
861
970
1160
1402
1504

116 0010 002


116 0010 003
116 0010 004
116 0010 005
116 0010 007
116 0010 012
116 0010 014

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
14 G 1,0

48,0
62,0
78,0
91,0
118,0
185,0
198,0

9,2
9,9
10,5
11,5
13,6
16,2
17,0

114
142
175
205
264
420
433

ConCab kabel connects the world

kg / km

213

CC-Multinorm-167
PVC-control cable with approvals
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 167 4G1,5 E172073 cus AWM STYLE 2587 600V 90C <HAR>

Technical data
DIN VDE/IEC:
UL/CSA:
The CC-Multinorm-167 with UL/CSA approval,
is especially designed for the North American market.
It is suitable as a control, regulating and measuring
cable especially when free unrestricted movement
is required. It is used in machine tool, plant and
apparatus construction, heating, air conditioning,
ventilation technology and for other electrical
equipment as well as where stipulations for oil
resistance under DIN VDE 0281, part 13 resp.
HD 21.13 S1 are required. The outer sheath, based on
PVC, is extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free of harmful
substances.

Construction
Fine strands of bare copper wire with PVC core
insulation. Cores black with consecutive
white numbering. 3 cores or more with
protective green/yellow conductor in the outer
layer. Cores twisted in layers. Oil resistant PVC-based
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2 bzw. EN 50265-1,
IEC 60332-1 and CSA FT 1).
Outer sheath colour grey (RAL 7001).

214

Rated voltage:
300/500 V
600 V
Test voltage:
3000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
Temperature range:
HAR -40C up to +70C
UL/CSA -40C up to +90C
flexible application:
HAR -5C up to +70C
UL/CSA -5C up to +90C
fixed installation:

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

Norms:
UL:AWM-Style 1012
UL:Style 2587, VW-1
CSA:AWM I A/B, II A/B, FT1
from 4 mm2 solely acc. to UL and CSA

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

167 20 02
167 20 03
167 20 04
167 20 05
167 20 07
167 20 09
167 20 12
167 20 18
167 20 25
167 20 34
167 20 41

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
9 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
41 G 0,5

2 X AWG 20
3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
9 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20
34 X AWG 20
41 X AWG 20

9,7
14,4
20,5
24,9
34,0
43,0
58,0
86,4
120,0
163,2
196,0

5,9
6,2
7,0
7,4
9,3
11,4
11,4
13,4
16,2
19,5
21,0

52
63
69
87
119
150
198
260
380
509
595

167 19 02
167 19 03
167 19 04
167 19 05
167 19 07
167 19 09
167 19 12
167 19 18
167 19 25
167 19 34
167 19 41

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
9 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75

2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
9 X AWG 19
12 X AWG 19
18 X AWG 19
25 X AWG 19
34 X AWG 19
41 X AWG 19

14,4
22,0
29,0
36,0
50,0
65,0
86,0
130,0
180,0
245,0
296,0

6,3
6,8
7,5
8,1
10,1
12,2
12,2
14,3
17,7
19,8
21,5

66
76
85
113
145
231
245
338
467
626
748

167 18 02
167 18 03
167 18 04
167 18 05
167 18 07
167 18 09
167 18 12
167 18 18
167 18 25
167 18 34
167 18 41

2 X1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
9 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18

19,2
29,0
38,4
48,0
67,0
86,4
115,0
173,0
240,0
326,0
394,0

6,8
7,2
7,8
8,8
10,4
12,2
13,0
15,5
18,4
20,9
22,7

80
89
104
132
183
230
286
405
570
742
886

167 16 02
167 16 03
167 16 04
167 16 05
167 16 07
167 16 09
167 16 12
167 16 18
167 16 25
167 16 34
167 16 41
167 16 50

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5
50G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
41 X AWG 16
50 X AWG 16

29,0
43,0
58,0
72,0
101,0
130,0
173,0
259,0
360,0
490,0
591,0
720,0

7,7
8,6
9,3
10,3
12,0
14,6
14,6
17,6
21,8
26,0
26,4
29,5

95
110
141
168
225
254
361
518
730
865
1136
1381

ConCab kabel connects the world

215

CC-Multinorm-167
PVC-control cable with approvals
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

167 14 02
167 14 03
167 14 04
167 14 05
167 14 07
167 14 09
167 14 12
167 14 18
167 14 25

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
9 G 2,5
12 G 2,5
18 G 2,5
25 G 2,5

2 X AWG 14
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
9 X AWG 14
12 X AWG 14
18 X AWG 14
25 X AWG 14

48,0
72,0
96,0
120,0
168,0
216,0
288,0
432,0
600,0

9,0
9,7
10,8
11,9
14,7
17,0
17,8
21,4
26,1

125
170
210
257
340
433
580
860
1175

167 12 03
167 12 04
167 12 05
167 12 07

3G4
4G4
5G4
7G4

3 X AWG 12
4 X AWG 12
5 X AWG 12
7 X AWG 12

115,0
154,0
192,0
269,0

10,4
11,1
12,4
13,7

226
274
355
462

167 10 03
167 10 04
167 10 05
167 10 07

3G6
4G6
5G6
7G6

3 X AWG 10
4 X AWG 10
5 X AWG 10
7 X AWG 10

173,0
231,0
288,0
403,0

12,3
13,5
15,2
18,9

349
402
487
633

167 08 03
167 08 04
167 08 05
167 08 07

3 G 10
4 G 10
5 G 10
7 G 10

3 X AWG 8
4 X AWG 8
5 X AWG 8
7 X AWG 8

288,0
384,0
480,0
672,0

15,4
17,4
20,0
23,4

533
634
781
1128

167 06 03
167 06 04
167 06 05
167 06 07

3 G 16
4 G 16
5 G 16
7 G 16

3 X AWG 6
4 X AWG 6
5 X AWG 6
7 X AWG 6

461,0
614,0
768,0
1075,0

18,6
22,8
23,0
24,5

844
1063
1241
1754

167 04 03
167 04 04
167 04 05
167 04 07

3 G 25
4 G 25
5 G 25
7 G 25

3 X AWG 4
4 X AWG 4
5 X AWG 4
7 X AWG 4

720,0
960,0
1200,0
1680,0

23,4
26,8
28,6
34,6

1200
1593
1991
2846

167 02 03
167 02 04
167 02 05

3 G 35
4 G 35
5 G 35

3 X AWG 2
4 X AWG 2
5 X AWG 2

1008,0
1344,0
1680,0

26,3
30,0
32,5

1612
2118
2621

from cross-section 4 mm2 in accordance to

216

ConCab kabel connects the world

CC-Multinorm-CY-168
Oil resistant PVC-control cable with approvals, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 168 25G1,5 E172073 cus AWM STYLE 2587 600V 90C <HAR>

Technical data

The CC-Multinorm-CY-168 shielded, with UL/CSA


approval, is especially designed for the North
American market. It is suitable as a control,
regulating and measuring cable especially when free
unrestricted movement is required. It is used in
machine tool, plant and apparatus construction,
heating, air conditioning, ventilation technology and
for other electrical equipment where a greater
electromagnetic compatibility (EMC) as well as
stipulations for oil resistance under DIN VDE 0281,
part 13 resp. HD 21.13 S1 are required. The outer
sheath, based on PVC, is extremely resistant to oil and
chemicals. It is free of silicone, cadmium and free of
harmful substances.

Construction
Fine strands of bare copper wire with PVC core
insulation. Cores black with consecutive
white numbering. 3 cores or more with
protective green/yellow conductor in the outer layer.
Cores twisted in layers. PVC inner sheath, overall
tinned copper shield. Oil resistant PVC-based outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2 bzw. EN 50265-1,
IEC 60332-1 and CSA FT 1).
Colour grey (RAL 7001).

DIN VDE/IEC:
UL/CSA:

Rated voltage:
300/500 V
600 V
Test voltage:
3000 V

Conductor stranding:
fine copper strands acc. to DIN VDE 0295
class 5 resp. UL-Style 1012
Insulation resistance:
min. 20 MOhm X km
Temperature range:
HAR -40C up to +70C
UL/CSA -40C up to +90C
flexible application:
HAR -5C up to +70C
UL/CSA -5C up to +90C
fixed installation:

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

Norms:
UL:AWM-Style 1012
UL:Style 2587, VW-1
CSA:AWM I A/B, II A/B, FT1
from 4 mm2 solely acc. to UL and CSA

ConCab kabel connects the world

217

CC-Multinorm-CY-168
Oil resistant PVC-control cable with approvals, shielded
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

218

No. of cores

No. of cores

+
crosssection

168 20 02
168 20 03
168 20 04
168 20 05
168 20 07
168 20 09
168 20 12
168 20 18
168 20 25
168 20 34
168 20 41

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
9 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
41 G 0,5

2 X AWG 20
3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
9 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20
34 X AWG 20
41 X AWG 20

28,3
34,9
46,7
53,5
68,0
87,3
110,0
153,0
199,0
282,4
330,0

8,1
8,4
9,1
9,9
11,4
11,6
13,9
16,0
19,6
21,6
24,0

92
109
126
156
195
230
280
418
556
634
770

168 19 02
168 19 03
168 19 04
168 19 05
168 19 07
168 19 09
168 19 12
168 19 18
168 19 25
168 19 34
168 19 41

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
9 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75

2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
9 X AWG 19
12 X AWG 19
18 X AWG 19
25 X AWG 19
34 X AWG 19
41 X AWG 19

36,5
45,2
54,6
64,4
83,7
125,0
138,0
194,0
276,0
352,0
418,0

8,8
9,2
10,0
10,3
12,4
13,4
14,8
17,0
21,2
23,7
24,5

110
127
157
184
235
268
355
517
678
861
970

168 18 02
168 18 03
168 18 04
168 18 05
168 18 07
168 18 09
168 18 12
168 18 18
168 18 25
168 18 34
168 18 41

2 X1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
9 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18

43,3
54,4
66,4
78,7
108,0
135,0
174,0
269,0
352,0
450,0
538,0

8,9
8,9
10,1
11,1
12,7
15,1
16,6
19,1
22,0
25,6
26,6

102
145
180
205
273
325
425
580
766
996
1155

168 16 02
168 16 03
168 16 04
168 16 05
168 16 07
168 16 09
168 16 12
168 16 18
168 16 25
168 16 34
168 16 41

2 X1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16
34 X AWG 16
41 X AWG 16

55,9
72,1
89,2
112,0
148,0
185,0
252,0
353,0
494,0
639,0
767,0

9,9
10,2
11,4
13,0
14,8
17,0
17,6
20,5
24,6
27,2
29,3

151
176
235
245
314
360
500
657
950
1204
1453

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

168 14 02
168 14 03
168 14 04
168 14 05
168 14 07
168 14 09
168 14 12
168 14 18
168 14 25

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
9 G 2.5
12 G 2.5
18 G 2.5
25 G 2.5

168 12 03
168 12 04
168 12 05
168 12 07

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

2 X AWG 14
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
9 X AWG 14
12 X AWG 14
18 X AWG 14
25 X AWG 14

86,9
114,0
148,0
178,0
236,0
322,0
399,0
590,0
795,0

11,3
11,9
13,4
14,4
17,1
21,2
21,2
26,1
31,3

202
245
296
367
480
589
670
2052
1375

3G4
4G4
5G4
7G4

3 X AWG 12
4 X AWG 12
5 X AWG 12
7 X AWG 12

198,0
232,0
275,0
395,0

12,8
13,5
14,6
17,4

310
456
532
737

168 10 03
168 10 04
168 10 05
168 10 07

3G6
4G6
5G6
7G6

3 X AWG 10
4 X AWG 10
5 X AWG 10
7 X AWG 10

242,0
316,0
411,0
570,0

16,6
16,5
18,5
20,9

411
572
732
961

168 08 03
168 08 04
168 08 05
168 08 07

3 G 10
4 G 10
5 G 10
7 G 10

3 X AWG 8
4 X AWG 8
5 X AWG 8
7 X AWG 8

416,0
571,0
690,0
971,0

17,2
20,4
22,0
26,0

741
988
1202
1743

168 06 03
168 06 04
168 06 05
168 06 07

3 G 16
4 G 16
5 G 16
7 G 16

3 X AWG 6
4 X AWG 6
5 X AWG 6
7 X AWG 6

660,0
821,0
1127,0
1512,0

23,6
25,8
29,0
32,0

1088
1662
2021
2720

168 04 03
168 04 04
168 04 05
168 04 07

3 G 25
4 G 25
5 G 25
7 G 25

3 X AWG 4
4 X AWG 4
5 X AWG 4
7 X AWG 4

1091,0
1443,0
1802,0
2520,0

28,0
29,9
34,0
39,0

1947
2591
3197
4530

168 02 03
168 02 04
168 02 05

3 G 35
4 G 35
5 G 35

3 X AWG 2
4 X AWG 2
5 X AWG 2

1501,0
1859,0
2532,0

30,0
32,0
37,0

2701
3277
4530

from cross-section 4 mm2 in accordance to

ConCab kabel connects the world

219

CC-Control Tray TM-170


Flexible oil resistant control cable 600 V
for cable trays and open wiring at machines
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 170 E 337473  TC OPEN WIRING OR MTW 600V 90C

NFPA 79 EDITION 2007


NEW Electrical Standard for Industrial Machinery USA
TC-ER Tray Cable Exposed Run

CC-Control Tray TM-170, NFPA 79 approved, is


specially designed on the requirements of the North
American market. This control cable can be used for the
open, unprotected wiring between cable trays and
machineries or industrial equipment. Special PVCcompound, flame retardant and can be used in dry, damp
and wet areas. A specific technical design
guarantees an optimized, failure-free operation.

Technical data
Rated voltage:
DIN VDE/IEC:
UL:

Test voltage:
2000 V

Additional Applications
- Wind turbines: USA Wind Turbine Tray Cable (WTTC)
- Machine tools UL MTW (Machine Tool Wiring)
- Class 1, Div. 2 acc. to NEC National Electrical Code

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

part. 336. 10 (7)

Construction
Fine strands of bare copper wires, special PVC-based
core insulation with transparent polyamide
(Nylon) skin, cores are black with consecutive white
numbering and green/yellow protective conductor, cores
twisted together. PVC outer sheath,
flame retardant (acc. to FT4) and self-extinghuising (acc.
to DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1,
IEC 60332-1). Colour grey (RAL 7001).

220

300/500V
600 V TC-ER

min. 200 MOhm X km

Temperature range:
fixed installation:
flexible application:
fixed installation:

-40C to +90C
-5C to +90C

Bending radius:

5 X cable diameter

Approvals:

UL: MTW, cUL,


TC-ER (Tray Cable Exposed Run) FT4

ConCab kabel connects the world

Part No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

170 18 03
170 18 04
170 18 05
170 18 07
170 18 12
170 18 18
170 18 25

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18

29,0
38,5
48,0
67,0
116,0
174,0
240,0

7,3
7,9
8,5
9,2
12,0
14,6
17,4

83
96
113
144
248
366
464

170 16 02
170 16 03
170 16 04
170 16 05
170 16 07
170 16 09
170 16 12
170 16 18
170 16 25

2 G 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16

28,8
43,0
58,0
72,0
102,0
129,6
173,0
259,0
360,0

7,5
7,9
8,6
9,3
10,2
12,6
14,0
16,1
19,2

75
100
120
141
184
247
328
403
464

170 14 03
170 14 04
170 14 05
170 14 07

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14

72,0
96,0
120,0
168,0

8,8
9,5
10,5
11,4

125
155
185
244

170 12 03
170 12 04
170 12 05
170 12 07

3G4
4G4
5G4
7G4

3 X AWG 12
4 X AWG 12
5 X AWG 12
7 X AWG 12

115,0
154,0
192,0
269,0

10,2
11,1
12,1
14,0

135
220
269
482

170 10 04
170 10 05

4G6
5G6

4 X AWG 10
5 X AWG 10

231,0
288,0

14,1
15,4

382
457

170 08 04
170 08 05

4 G 10
5 G 10

4 X AWG 8
5 X AWG 8

384,0
480,0

18,6
20,5

615
771

170 06 04

4 G 16

4 X AWG 6

615,0

22,4

864

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

221

CC-Control Tray TM-CY-171


Flexible oil resistant control cable 600 V, shielded
for cable trays and open wiring at machines
Conforms to EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 171 E337473  TC OPEN OR MTW 600V 90C

NFPA 79 EDITION 2007


NEW Electrical Standard for Industrial Machinery USA
TC-ER Tray Cable Exposed Run

CC-Control Tray TM-CY-171, NFPA 79 approved,


is specially designed on the requirements of the North
American market. This control cable can be used for the
open, unprotected wiring between cable trays and machineries or industrial equipment.
Special PVC-compound, flame retardant and can be used
in dry, damp and wet areas. A specific technical design
guarantees an optimized, failure-free operation.

Additional Applications
- Wind turbines: USA Wind Turbine Tray Cable (WTTC)
- Machine tools UL MTW (Machine Tool Wiring)
- Class 1, Div. 2 acc. to NEC National Electrical Code

Technical data
Rated voltage:
DIN VDE/IEC:
UL:

Test voltage:
2000 V

Conductor stranding:

fine copper strands


acc. to DIN VDE 0295, class 5

Insulation resistance:

min. 200 MOhm X km

part. 336. 10 (7)

Construction
Fine strands of bare copper wires, special PVC-based
core insulation with transparent polyamide
(Nylon) skin, cores are black with consecutive white
numbering and green/yellow protective conductor, cores
twisted together, aluminium foil, tinned copper braid.
PVC outer sheath, flame retardant (acc. to FT4) and selfextinghuising (acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1, IEC 60332-1). Colour grey (RAL 7001).

222

300/500 V
600 V TC-ER

Temperature range:
fixed installation:
flexible application:

-40C to +90C
-5C to +90C

Bending radius:
fixed installation:

6 X cable diameter

Approvals:

UL: MTW, cUL,


TC-ER (Tray Cable Exposed Run) FT4

ConCab kabel connects the world

Part No.

No of cores

No of cores

+
crosssection

171 18 03
171 18 04
171 18 05
171 18 07
171 18 12
171 18 18
171 18 25

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18

50,0
61,0
81,6
102,0
162,0
229,0
327,0

8,1
8,6
9,3
10,1
12,9
15,5
18,3

119,0
137,0
150,0
104,0
331,0
439,0
576,0

171 16 02
171 16 03
171 16 04
171 16 05
171 16 07
171 16 12
171 16 18
171 16 25

2 G 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16

50,0
65,0
80,0
100,0
141,0
226,0
321,0
454,0

8,3
8,6
9,4
10,1
11,0
14,9
17,2
20,2

116,0
144,0
174,0
190,0
247,0
427,0
551,0
750,0

171 14 03
171 14 04
171 14 05
171 14 07

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14

105,0
136,0
161,0
214,0

9,6
10,4
11,2
12,4

179,0
224,0
269,0
328,0

171 12 04
171 12 05
171 12 07

4G4
5G4
7G4

4 X AWG 12
5 X AWG 12
7 X AWG 12

198,0
243,0
323,0

11,9
13,1
14,9

314,0
388,0
500,0

171 10 04
171 10 05

4G6
5G6

4 X AWG 10
5 X AWG 10

285,0
349,0

14,8
16,3

553,0
614,0

171 08 04

4 G 10

4 X AWG 8

459,0

19,7

858,0

171 06 04

4 G 16

4 X AWG 6

724,0

23,5

1.208,0

Special needs, different dimensions or different outer sheath colours upon request.

ConCab kabel connects the world

223

CC-control cable-CEI-FR-162
Flame retardant PVC-control cable acc. to Italian standard CEI 20-22II
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 162 5G1,5 CEI-FR 20-22II

The CC-control cable-CEI-FR-162 is


especially approved for the Italian market. It is
suitable as a control, regulating and measuring cable
when free unrestricted movement is required. It has an
improved fire characteristics and it used for higher
protection of humans and materials in case of fire.
It is used in machine tool, plant and apparatus
construction, heating, air conditioning and ventilation
technology and in data processing and transport
technological applications. The outer sheath, based on
PVC, is extremely resistant to oil and chemicals.
It is free of silicone, cadmium and free of harmful
substances.

Technical data
Rated voltage:

up to 1,0 mm2:
from 1,5 mm2:

Test voltage:
2000 V

Conductor stranding:

fine copper strands


acc. to CEI 20-29, class 5

Insulation resistance:

Construction
Fine strands of bare copper wire with PVC core
insulation. Up to 5 cores, cores are coloured acc. to
DIN VDE 0293, part 308. 6 cores or more, cores
black with consecutive white numbering. 3 cores or
more with protective green/yellow conductor in the
outer layer. Cores twisted in layers.
PVC outer sheath, oil and petrol resistant (acc. to
CEI 20-22II) as well as flame retardant and
self-extinguishing (acc. to IEC 60332-3).
Colour grey (RAL 7001).

224

300/500 V
450/750 V

min. 20 MOhm X km

fixed installation:
flexible application:
fixed installation:
flexible application:

ConCab kabel connects the world

Temperature range:

-40C to +70C
-5C to +70C

Bending radius:

5 X cable diameter
15 X cable diameter

Approvals:
CEI 20-22II

Part-No.

No. of cores
+
crosssection

Copper
weight

162 0010 003


162 0010 004
162 0010 005
162 0010 007
162 0010 012
162 0010 018
162 0010 025
162 0010 027
162 0010 033
162 0010 034
162 0010 042
162 0010 050

3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
27 G 1,0
33 G 1,0
34 G 1,0
42 G 1,0
50 G 1,0

29,0
39,0
48,0
67,0
115,0
173,0
240,0
259,0
317,0
326,0
405,0
480,0

8,5
9,5
10,5
10,8
13,8
16,5
19,5
20,0
20,8
21,0
23.3
25,0

85
100
123
160
270
380
500
560
700
720
800
1050

162 0015 003


162 0015 004
162 0015 005
162 0015 007
162 0015 012
162 0015 018
162 0015 025
162 0015 034
162 0015 037
162 0015 042
162 0015 050

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
37 G 1,5
42 G 1,5
50 G 1,5

43,0
58,0
72,0
101,0
173,0
259,0
360,0
490,0
533,0
605,0
720,0

9,6
11,0
12,0
12,5
16,0
18,8
23,0
26,0
26,5
29,5
30,5

105
150
190
220
350
515
705
990
1005
1080
1330

162 0025 003


162 0025 004
162 0025 005
162 0025 007
162 0025 012

3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5

72,0
96,0
120,0
168,0
288,0

11,3
12,3
12,6
14,5
18,0

190
215
270
350
550

162 0040 004


162 0040 007

4G4
7G4

154,0
269,0

14,0
16,0

300
500

kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

Part-No.

No. of cores
+
crosssection

Copper
weight

162 0060 004

4G6

230,0

16,0

430

162 0100 004

4 G 10

384,0

19,0

700

162 0160 004

4 G 16

614,0

23,0

1000

162 0250 004

4 G 25

960,0

28,0

1550

162 0350 004

4 G 35

1344,0

31,0

2070

162 0500 004

4 G 50

1920,0

37,0

2850

162 0700 004

4 G 70

2688,0

43,0

4000

162 0950 004

4 G 95

3648,0

50,0

5400

ConCab kabel connects the world

kg/km

Outer dia- Weight


meter
approx.
mm
kg/km

225

226

ConCab kabel connects the world

227

CC-control cable PUR-JZ-141


and PUR-OZ-148

Numbered black cores with / without protective conductor


Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 141 34 G 1,5 JZ

Technical data
Rated voltage:
300/500 V
The flexible CC-control cable PUR-JZ-141
resp. OZ-148 is suitable as a control and
signal cable in machine tools, machine and
appliance construction. It is particularly applicable
for contact with mineral oil and for applications with
high mechanical stress. The polyurethane outer
sheath fulfils the highest demands of wear and tear as
well as impact requirements. CC-control cables PUR
are free of lacquer destructive substances
(silicone free).

Construction
Fine strands of bare copper wire, PVC core
insulation. Cores black with consecutive white
numbering. With -JZ, 3 cores or more with protective
green/yellow conductor in the outer layer. Cores
twisted in layers. PUR outer sheath, non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

228

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation:
5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

141 0005 002


141 0005 003
148 0005 003
141 0005 004
148 0005 004
141 0005 005
148 0005 005
141 0005 007
148 0005 007
141 0005 010
141 0005 012
141 0005 018
141 0005 025
141 0005 034
141 0005 041

2 X 0,5
3 G 0,5
3 X 0,5
4 G 0,5
4 X 0,5
5 G 0,5
5 X 0,5
7 G 0,5
7 X 0,5
10 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
41 G 0,5

10,0
15,0
witho. gnye
20,0
witho. gnye
24,0
witho. gnye
33,0
witho. gnye
48,0
57,0
88,0
118,0
161,0
194,0

4,9
5,2
5,2
5,8
5,8
6,3
6,3
6,8
6,8
8,7
9,0
10,6
12,5
14,4
15,8

32
39
39
39
39
59
59
76
76
109
125
180
250
333
400

141 0007 002


141 0007 003
148 0007 003
141 0007 004
148 0007 004
141 0007 005
148 0007 005
141 0007 007
148 0007 007
141 0007 012
141 0007 018
141 0007 025
141 0007 034
141 0007 041

2 X 0,75
3 G 0,75
3 X 0,75
4 G 0,75
4 X 0,75
5 G 0,75
5 X 0,75
7 G 0,75
7 X 0,75
12 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75

14,4
22,5
witho. gnye
29,0
witho. gnye
36,0
witho. gnye
50,0
witho. gnye
86,0
130,0
180,0
236,0
284,0

5,6
5,8
5,8
6,6
6,6
7,3
7,3
8,2
8,2
10,2
12,2
14,0
15,9
17,4

43
51
51
66
66
84
84
105
105
180
260
340
431
529

141 0010 002


141 0010 003
148 0010 003
141 0010 004
148 0010 004
141 0010 005
148 0010 005
141 0010 007
141 0010 009
141 0010 012
141 0010 018
141 0010 025
141 0010 034
141 0010 041

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
5 X 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

19,2
29,0
witho. gnye
38,4
witho. gnye
48,0
witho. gnye
67,0
86,4
115,0
173,0
240,0
336,0
393,0

5,8
6,4
6,4
6,9
6,9
7,5
7,5
8,3
9,1
11,0
13,0
15,3
17,1
18,8

50
64
64
78
78
100
100
129
185
220
310
425
532
638

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

141 0015 002


141 0015 003
148 0015 003
141 0015 004
148 0015 004
141 0015 005
148 0015 005
141 0015 007
141 0015 012
141 0015 018
141 0015 025
141 0015 034
141 0015 041

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5

29,0
40
witho. gnye
58
witho. gnye
72
witho. gnye
101,0
173,0
259,0
360,0
490,0
590,0

6,4
6,7
6,7
7,2
7,2
8,1
8,1
8,9
12,3
14,0
17,2
19,9
22,0

67
79
79
98
98
121
121
173
285
410
586
840
980

141 0025 003


141 0025 004
141 0025 005
141 0025 007
141 0025 012

3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5

72,0
96,0
120,0
168,0
288,0

8,3
9,2
10,3
11,3
15,1

132
169
210
265
469

141 0040 004


141 0040 005
141 0040 007

4G4
5G4
7G4

154,0
192,0
269,0

11,1
12,4
13,7

269
317
391

141 0060 004


141 0060 005
141 0060 007

4G6
5G6
7G6

230,0
288,0
403,0

13,2
14,8
16,3

378
448
582

141 0100 004


141 0100 005

4 G 10
5 G 10

384,0
480,0

16,5
18,4

600
721

141 0160 004

4 G 16

614,0

21,4

1050

ConCab kabel connects the world

229

CC-two norm PUR-141


Oil resistant PUR-control cable with approvals
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 141 34 G 1,5 QMM E172073 c AWM STYLE 20234 600V 80C

Technical data
Rated voltage:
DIN VDE/IEC:
300/500 V
UL/CSA:
600 V

The oil resistant CC-control cable PUR-141 with


UL/CSA approval, is designed especially for
the North American market as a control cable applied
in machine tool, machine and apparatus construction.
It is particularly suitable where aggressive substances
like mineral oil occur and for applications with high
mechanical stress. The polyurethane outer sheath
fulfils the highest demands of wear and tear as well as
impact requirements. CC-control cables PUR are free
of lacquer destructive substances
(silicone free).

Construction
Fine strands of bare copper wire, PVC core insulation.
Cores black with consecutive white numbering.
3 cores or more with protective green/yellow conductor
in the outer layer. Cores twisted in layers. PUR outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1
esp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

230

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0282
UL: Style 10012/20234
CSA: AWM I A/B, II A/B, FTI

ConCab kabel connects the world

Part-No.

No. of cores

No. of cores

+
crosssection

+
AWG

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

141 20 02
141 20 03
141 20 04
141 20 05
141 20 07
141 20 09
141 20 12
141 20 18
141 20 25

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
9 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

2 X AWG 20
3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
9 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20

9,6
14,4
19,2
24,0
34,0
43,2
58,0
86,4
120,0

6,2
6,5
7,0
7,6
8,2
9,7
10,6
12,3
14,8

52
58
70
80
100
121
146
205
262

141 19 02
141 19 03
141 19 04
141 19 05
141 19 07
141 19 09
141 19 12
141 19 18
141 19 25

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
9 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75

2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
9 X AWG 19
12 X AWG 19
18 X AWG 19
25 X AWG 19

14,4
21,6
28,8
36,0
50,4
64,8
86,4
129,6
180,0

6,8
7,2
7,7
8,3
9,0
10,5
11,5
13,4
15,9

60
71
86
105
126
149
178
254
337

141 18 02
141 18 03
141 18 04
141 18 05
141 18 07
141 18 09
141 18 12
141 18 18
141 18 25
141 18 34
141 18 41
141 18 50

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
9 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
50 X AWG 18

19,2
29,0
38,4
48,0
67,2
86,4
115,0
173,0
240,0
326,4
393,6
480,0

7,0
7,4
7,9
8,6
9,3
11,0
12,1
14,3
17,0
19,7
21,6
23,0

67
77
95
112
137
171
213
302
394
543
624
726

141 16 02
141 16 03
141 16 04
141 16 05
141 16 07
141 16 09
141 16 12
141 16 18
141 16 25
141 16 41
141 16 50

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
41 G 1,5
50 G 1,5

2 X AWG16
3 X AWG16
4 X AWG16
5 X AWG16
7 X AWG16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16
41 X AWG 16
50 X AWG 16

29,0
43,2
58,0
72,0
101,0
130,0
173,0
261,0
363,0
594,0
720,0

7,6
8,0
8,7
9,4
10,7
12,0
13,3
15,5
18,5
24,0
25,1

79
94
115
135
170
211
266
378
499
795
955

141 14 02
141 14 03
141 14 04
141 14 05
141 14 07
141 14 09
141 14 12
141 14 18

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
9 G 2.5
12 G 2.5
18 G 2.5

2 X AWG 14
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
9 X AWG 14
12 X AWG 14
18 X AWG 14

48,0
72,0
96,0
120,0
168,0
216,0
288,0
432,0

8,6
9,1
9,9
10,8
11,7
13,9
15,3
17,9

98
113
150
179
231
289
353
530

231

CC-control cable PUR-C-JZ-142


and PUR-C-OZ-144

Numbered black cores, shielded


Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt C-142 25G1,5 JZ-C

Technical data
The flexible CC-control cable PUR-C-JZ-142 resp.
OZ-144 are suitable as control cables in machine tool,
machine and appliance construction. They are
particularly applicable for contact with mineral oil and
for applications with high mechanical stress.
The copper shield protects against any electrical
interference. The polyurethane outer sheath fulfils
the highest demands of wear and tear as well as
impact requirements. CC-control cables PUR are free
of lacquer destructive substances (silicone free).

Construction
Fine strands of bare copper wire, PVC core insulation.
Cores black with consecutive white numbering.
Type-JZ, 3 cores or more with protective
green/yellow conductor in the outer layer. Cores
twisted in layers. PVC inner sheath with overall
tinned copper shield and fleece. PUR outer sheath,
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

232

Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation:
5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

142 0005 002


142 0005 003
142 0005 004
142 0005 005
142 0005 007
142 0005 012
142 0005 018
142 0005 025
142 0005 034
142 0005 041

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5
41 G 0,5

41,0
45,5
55,0
66,0
80,5
138,5
180,0
251,0
395,0
451,0

6,4
7,0
7,5
8,3
9,5
11,5
13,0
16,0
17,0
19,2

67
56
95
105
135
200
280
410
590
670

142 0007 002


142 0007 003
144 0007 003
142 0007 004
144 0007 004
142 0007 005
144 0007 005
142 0007 007
144 0007 007
142 0007 012
142 0007 018
142 0007 025
142 0007 034
142 0007 041

2 X 0,75
3 G 0,75
3 X 0,75
4 G 0,75
4 X 0,75
5 G 0,75
5 X 0,75
7 G 0,75
7 X 0,75
12 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75

45,0
57,9
witho.gnye
64,0
witho.gnye
77,4
witho.gnye
102,0
witho.gnye
138,0
243,0
324,0
431,0
500,0

7,3
7,8
7,8
8,3
8,3
8,9
8,9
9,9
9,9
12,2
14,6
17,1
18,7
21,0

85
100
100
115
115
132
132
169
169
245
356
465
601
728

142 0010 002


142 0010 003
144 0010 003
142 0010 004
144 0010 004
142 0010 005
142 0010 007
142 0010 012
142 0010 018
142 0010 025
142 0010 034
142 0010 041

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

56,0
77,0
witho.gnye
78,1
witho.gnye
89,4
120,0
192,0
289,0
393,0
532,0
590,0

8,0
8,3
8,3
8,8
8,8
9,7
11,2
13,6
16,2
19,0
21,3
23,0

99
115
115
132
132
160
186
310
418
545
741
865

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

142 0015 002


142 0015 003
144 0015 003
142 0015 004
144 0015 004
142 0015 005
144 0015 005
142 0015 007
144 0015 007
142 0015 012
142 0015 018
142 0015 025
142 0015 034
142 0015 041

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
7 G 1,5
7 X 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5

75,0
84,0
witho.gnye
100,0
witho.gnye
125,0
witho.gnye
196,0
witho.gnye
280,0
392,0
572,0
722,0
850,0

8,5
8,9
8,9
9,6
9,6
10,5
10,5
11,7
11,7
15,0
17,8
20,6
23,2
25,7

118
131
131
165
165
193
193
238
238
401
544
748
955
1123

142 0025 003


142 0025 004
142 0025 005
142 0025 007
142 0025 012

3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5

146,0
173,0
200,0
288,0
477,3

10,6
11,9
13,0
14,9
18,2

203
241
295
371
584

142 0040 004


142 0040 005

4G4
5G4

237,0
307,0

14,2
15,7

385
480

142 0060 004


142 0060 005

4G6
5G6

350,0
441,0

15,5
17,8

463
630

142 0100 004

4 G 10

558,0

19,3

850

142 0160 004

4 G 16

810,0

22,8

1380

ConCab kabel connects the world

233

CC-two norm PUR-C-142


Oil resistant PUR-control cable with approvals, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt C-142 25G1,5 E172073 cus AWM STYLE 20234 600V 80C

Technical data

The oil resistant shielded CC-control cable


PUR-C-142 with UL/CSA approval is designed
especially for the North American market as a
control cable applied in machine tool, machine and
apparatus construction. It is particularly suitable
where aggressive substances like mineral oil occur and
for applications with high mechanical stress.
The copper shield protects against electrical
interference. The polyurethane outer sheath fulfils the
highest demands of wear and tear as well as impact
requirments. CC-control cables PUR are free of
lacquer destructive substances (silicone free).

Construction
Fine strands of bare copper wire with PVC core
insulation. Cores black with consecutive white
numbering. 3 cores or more with protective
green/yellow conductor in the outer layer. Cores
twisted in layers. Fleece, tinned drain wire, tinned
copper shield. PUR outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

234

Rated voltage:
DIN VDE/IEC:
300/500 V
UL/CSA:
600 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation:
5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0280
UL-Style 10012/20234
CSA: AWM II A/B FT1

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

142 20 02
142 20 03
142 20 04
142 20 05
142 20 07
142 20 09
142 20 12
142 20 18
142 20 25

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
9 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

2 X AWG 20
3 X AWG 20
4 X AWG 20
5 X AWG 20
7 X AWG 20
9 X AWG 20
12 X AWG 20
18 X AWG 20
25 X AWG 20

22,6
27,9
34,8
41,8
52,1
66,0
83,1
131,8
174,9

7,0
7,3
7,8
8,4
9,0
10,4
11,3
13,2
15,5

68
83
97
109
126
153
173
244
318

142 19 02
142 19 03
142 19 04
142 19 05
142 19 07
142 19 09
142 19 12
142 19 18
142 19 25

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
9 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75

2 X AWG 19
3 X AWG 19
4 X AWG 19
5 X AWG 19
7 X AWG 19
9 X AWG 19
12 X AWG 19
18 X AWG 19
25 X AWG 19

28,2
36,3
45,3
54,1
70,5
89,4
113,7
179,3
240,7

7,4
7,8
8,3
8,9
9,6
11,1
12,1
14,2
16,7

80
95
110
125
150
181
218
301
391

142 18 02
142 18 03
142 18 04
142 18 05
142 18 07
142 18 09
142 18 12
142 18 18
142 18 25
142 18 34
142 18 41
142 18 50

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
50 G 1,0

2 X AWG 18
3 X AWG 18
4 X AWG 18
5 X AWG 18
7 X AWG 18
9 X AWG 18
12 X AWG 18
18 X AWG 18
25 X AWG 18
34 X AWG 18
41 X AWG 18
50 X AWG 18

33,6
44,5
56,1
68,0
88,4
112,1
143,8
224,4
301,0
421,7
504,7
592,4

7,6
8,0
8,5
9,2
9,9
11,5
12,7
14,9
17,6
20,5
22,1
23,8

91
106
122
140
173
208
263
357
463
635
746
893

142 16 02
142 16 03
142 16 04
142 16 05
142 16 07
142 16 09
142 16 12
142 16 18
142 16 25
142 16 41
142 16 50

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
9 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
41 G 1,5
50 G 1,5

2 X AWG 16
3 X AWG 16
4 X AWG 16
5 X AWG 16
7 X AWG 16
9 X AWG 16
12 X AWG 16
18 X AWG 16
25 X AWG 16
41 X AWG 16
50 X AWG 16

45,0
60,9
77,6
93,5
124,5
158,3
221,0
317,4
454,3
714,4
845,7

8,2
8,6
9,3
10,0
10,8
12,6
14,0
16,2
19,4
25,0
25,9

107
122
143
167
204
251
321
438
570
957
1116

142 14 02
142 14 03
142 14 04
142 14 05
142 14 07
142 14 09
142 14 12
142 14 18

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
9 G 2.5
12 G 2.5
18 G 2.5

2 X AWG 14
3 X AWG 14
4 X AWG 14
5 X AWG 14
7 X AWG 14
9 X AWG 14
12 X AWG 14
18 X AWG 14

68,0
92,1
118,8
145,5
196,3
267,5
396,9
526,1

9,2
9,7
10,5
11,4
12,3
14,7
16,1
18,1

125
152
185
216
271
336
427
582

235

CC-control cable PUR-JZ-143

Numbered black cores, flame retardant


Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 143 34G1,5 JZ

Technical data
Rated voltage:
300/500 V
The flexible CC-control cable PUR-JZ-143 is suitable
as a control cable in machine tool, machine and
appliance construction. It is particularly applicable for
contact with mineral oil and for applications with high
mechanical stress. The polyurethane outer sheath
fulfils the highest demands of wear and tear as well as
impact requirements. CC-control cables PUR are free
of lacquer destructive substances (silicone free).

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core insulation.
Cores black with consecutive white numbering.
3 cores or more with protective green/yellow
conductor in the outer layer. Cores twisted in layers.
PUR outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1),
non-adhesive, resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

236

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation:
5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

143 0005 002


143 0005 003
143 0005 004
143 0005 005
143 0005 007
143 0005 012
143 0005 018
143 0005 025
143 0005 034

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5
34 G 0,5

10,0
15,0
20,0
24,0
33,0
57,0
88,0
118,0
161,0

4,9
5,2
5,8
6,3
6,8
9,0
10,6
12,5
14,4

32
39
39
59
76
125
180
250
333

143 0007 002


143 0007 003
143 0007 004
143 0007 005
143 0007 007
143 0007 012
143 0007 018
143 0007 025
143 0007 034
143 0007 041

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75
34 G 0,75
41 G 0,75

14,4
22,5
29,0
36,0
50,0
86,0
130,0
180,0
236,0
284,0

5,6
5,8
6,6
7,3
8,2
10,2
12,2
14,0
15,9
17,4

43
51
66
84
105
180
260
340
431
529

143 0010 002


143 0010 003
143 0010 004
143 0010 005
143 0010 007
143 0010 012
143 0010 018
143 0010 025
143 0010 034
143 0010 041

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

19,2
29,0
38,4
48,0
67,0
115,0
173,0
240,0
336,0
393,0

5,8
6,4
6,9
7,5
8,3
11,0
13,0
15,3
17,1
18,8

50
64
78
100
129
220
310
425
532
638

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

141 0015 002


141 0015 003
141 0015 004
141 0015 005
141 0015 007
141 0015 012
141 0015 018
141 0015 025
141 0015 034
141 0015 041

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5

29,0
40,0
58,0
72,0
101,0
173,0
259,0
360,0
490,0
590,0

6,4
6,7
7,2
8,1
8,9
12,3
14,0
17,2
19,9
22,0

67
79
98
121
173
285
410
586
840
980

141 0025 003


141 0025 004
141 0025 005
141 0025 007
141 0025 012

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5

72,0
96,0
120,0
168,0
288,0

8,3
9,2
10,3
11,3
15,1

132
169
210
265
469

141 0040 004


141 0040 005
141 0040 007

4G4
5G4
7G4

154,0
192,0
269,0

11,1
12,4
13,7

269
317
391

141 0060 004


141 0060 005
141 0060 007

4G6
5G6
7G6

230,0
288,0
403,0

13,2
14,8
16,3

378
448
582

141 0100 004


141 0100 005

4 G 10
5 G 10

384,0
480,0

16,5
18,4

600
721

141 0160 004

4 G 16

614,0

21,4

1050

ConCab kabel connects the world

237

CC-control cable PUR-C-JZ-152

Numbered black cores, flame retardant, shielded


Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt C-152 25G1,5 JZ

The flexible CC-control cable PUR-C-JZ-152 is


suitable as a control cable in machine tool, machine
and appliance construction. It is particularly
applicable for contact with mineral oil and for
application with high mechanical stress. The copper
shield protects against any electrical interferences.
The polyurethane outer sheath fulfils the highest
demands of wear and tear as well as impact
requirements. CC-control cables PUR are free of
lacquer destructive substances
(silicone free).

Technical data
Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core insulation.
Cores black with consecutive white numbering.
3 cores or more with protective green/yellow
conductor in the outer layer. Cores twisted in layers.
PVC inner sheath with overall tinned copper shield
and fleece. PUR outer sheath, flame retardant and self
extinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1), non-adhesive,
resistant to hydrolysis and microbes.
Colour grey (RAL 7001).

238

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 12,5 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

152 0005 002


152 0005 003
152 0005 004
152 0005 005
152 0005 007
152 0005 012
152 0005 018
152 0005 025

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

41,0
45,5
55,0
66,0
80,5
138,5
180,0
251,0

6,4
7,0
7,5
8,3
9,5
11,5
13,0
16,0

67
56
95
105
135
200
280
410

152 0007 002


152 0007 003
152 0007 004
152 0007 005
152 0007 007
152 0007 012
152 0007 018
152 0007 025

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75

45,0
57,9
64,0
77,4
102,0
138,0
243,0
324,0

7,3
7,8
8,3
8,9
9,9
12,2
14,6
17,1

85
100
115
132
169
245
356
465

152 0010 002


152 0010 003
152 0010 004
152 0010 005
152 0010 007
152 0010 012
152 0010 018
152 0010 025
152 0010 034
152 0010 041

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0

56,0
77,0
78,1
89,4
120,0
192,0
289,0
393,0
532,0
590,0

8,0
8,3
8,8
9,7
11,2
13,6
16,2
19,0
21,3
23,0

99
115
132
160
186
310
418
545
741
865

Part-No.

No. of
cores
+
crosssection

Copper
weight
kg/km

Outer
Weight
diameter
approx.
mm

kg / km

152 0015 002


152 0015 003
152 0015 004
152 0015 005
152 0015 007
152 0015 012
152 0015 018
152 0015 025
152 0015 034
152 0015 041

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
41 G 1,5

75,0
84,0
100,0
125,0
196,0
280,0
392,0
572,0
722,0
850,0

8,5
8,9
9,6
10,5
11,7
15,0
17,8
20,6
23,2
25,7

118
131
165
193
238
401
544
748
955
1123

152 0025 003


152 0025 004
152 0025 005
152 0025 007
152 0025 012

3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5

146,0
173,0
200,0
288,0
477,3

10,6
11,9
13,0
14,9
18,2

203
241
295
371
584

152 0040 004


152 0040 005

4G4
5G4

237,0
307,0

14,2
15,7

385
480

152 0060 004


152 0060 005

4G6
5G6

350,0
441,0

15,5
17,8

463
630

152 0100 004

4 G 10

558,0

19,3

850

152 0160 004

4 G 16

810,0

22,8

1380

ConCab kabel connects the world

239

CC-Spiral cable PUR-997


Conforms to the EC low voltage guideline 73/23/EEC

Technical data
The CC-Spiral cable PUR-997 is suitable for
automatic handling equipment for in- and outdoor
applications in industries and other fields with high
mechanical stress. The polyurethan outer sheath is
abrasion and wear resistant as well as resistant against
mineral oils, grease, cooling liquids and gasoline.
Furthermore, the PUR- outer sheath is weather
resistant and resistant to microbes and hydrolysis.

Construction
Bare, fine strands of copper wires, PVC-based core
insulation, core colours acc. to DIN 47100,
from 0,5 mm2 cores are black with consecutive white
numbering and green/yellow protective conductor in
the outer layer, cores twisted in layers. PVC- or
PUR-based outer sheath is non-adhesive and resistant
to hydrolysis and microbes. Outer sheath colour
grey (RAL 7001), black (RAL 9005) or
orange (RAL 2003).

up to 0,34 mm2:
from 0,50 mm2:

Rated voltage:
300 V
300/500 V

up to 0,34 mm2:
from 0,50 mm2:

Test voltage:
1200 V
3000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
Temperature range:
-5C up to +70C
Gauge factor:
3,5 X closed length
Length for streight lengths:
End 1: 200 mm/ End 2: 600 mm

Part-No. specification:

Norms:
acc. to DIN VDE 0245, 0250, 0282
Outer sheath
Cross-section
No. of cores
Spiral length
Ends
Colour

Outer sheath:
996 = PVC
997 = PUR

Example:
997 2505 151 05 = Outer sheath PUR, Cross-section 2,5 mm2, No. of cores 5,
Spiral length 1500 mm, Ends tangential, Colour grey

240

ConCab kabel connects the world

Colour:
00 = black
05 = grey
08 = orange

Ends:
1 = tangential
2 = axial

Part-No.

No. of cores
+
crosssection

Spiral
length

Extended
length
approx.

Cable
diameter

Spiral
outer

Copper
weight

mm

mm

mm

approx.
mm

kg/piece

997 0102 011 00


997 0102 021 00
997 0102 031 00
997 0102 041 00
997 0102 051 00

2 X 0,14
2 X 0,14
2 X 0,14
2 X 0,14
2 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

4,1
4,1
4,1
4,1
4,1

17
17
17
17
17

0,02
0,02
0,03
0,04
0,05

997 0103 011 00


997 0103 021 00
997 0103 031 00
997 0103 041 00
997 0103 051 00

3 X 0,14
3 X 0,14
3 X 0,14
3 X 0,14
3 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

4,2
4,2
4,2
4,2
4,2

20
20
20
20
20

0,02
0,04
0,04
0,06
0,07

997 0104 011 00


997 0104 021 00
997 0104 031 00
997 0104 041 00
997 0104 051 00

4 X 0,14
4 X 0,14
4 X 0,14
4 X 0,14
4 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

4,6
4,6
4,6
4,6
4,6

21
21
21
21
21

0,03
0,04
0,05
0,06
0,07

997 0105 011 00


997 0105 021 00
997 0105 031 00
997 0105 041 00
997 0105 051 00

5 X 0,14
5 X 0,14
5 X 0,14
5 X 0,14
5 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

5,3
5,3
5,3
5,3
5,3

22
22
22
22
22

0,03
0,04
0,06
0,07
0,08

997 0106 011 00


997 0106 021 00
997 0106 031 00
997 0106 041 00
997 0106 051 00

6 X 0,14
6 X 0,14
6 X 0,14
6 X 0,14
6 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

5,6
5,6
5,6
5,6
5,6

23
23
23
23
23

0,03
0,05
0,07
0,08
0,10

997 0107 011 00


997 0107 021 00
997 0107 031 00
997 0107 041 00
997 0107 051 00

7 X 0,14
7 X 0,14
7 X 0,14
7 X 0,14
7 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

5,6
5,6
5,6
5,6
5,6

23
23
23
23
23

0,04
0,05
0,07
0,09
0,10

997 0112 011 00


997 0112 021 00
997 0112 031 00
997 0112 041 00
997 0112 051 00

12 X 0,14
12 X 0,14
12 X 0,14
12 X 0,14
12 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

7,2
7,2
7,2
7,2
7,2

29
29
29
29
29

0,07
0,10
0,13
0,17
0,20

997 0118 011 00


997 0118 021 00
997 0118 031 00
997 0118 041 00
997 0118 051 00

18 X 0,14
18 X 0,14
18 X 0,14
18 X 0,14
18 X 0,14

100
200
300
400
500

400
800
1200
1600
2000

8,0
8,0
8,0
8,0
8,0

31
31
31
31
31

0,08
0,12
0,16
0,20
0,25

ConCab kabel connects the world

241

CC-Spiralkabel PUR-997

Part-No.

242

No. of cores
+
crosssection

Spiral
length

Extended
length
approx.

Cable
diameter

Spiral
outer

Copper
weight

mm

mm

mm

approx.
mm

kg/piece

997 0702 051 05


997 0702 101 05
997 0702 151 05
997 0702 201 05

2 X 0,75
2 X 0,75
2 X 0,75
2 X 0,75

500
1000
1500
2000

1500
3000
4500
6000

5,5
5,5
5,5
5,5

20
20
20
20

0,08
0,14
0,20
0,25

997 0703 051 05


997 0703 101 05
997 0703 151 05
997 0703 201 05

3 G 0,75
3 G 0,75
3 G 0,75
3 G 0,75

500
1000
1500
2000

1500
3000
4500
6000

5,8
5,8
5,8
5,8

21
21
21
21

0,11
0,20
0,28
0,37

997 0704 051 05


997 0704 101 05
997 0704 151 05
997 0704 201 05

4 G 0,75
4 G 0,75
4 G 0,75
4 G 0,75

500
1000
1500
2000

1500
3000
4500
6000

6,3
6,3
6,3
6,3

22
22
22
22

0,15
0,25
0,35
0,50

997 0705 051 05


997 0705 101 05
997 0705 151 05
997 0705 201 05

5 G 0,75
5 G 0,75
5 G 0,75
5 G 0,75

500
1000
1500
2000

1500
3000
4500
6000

6,8
6,8
6,8
6,8

25
25
25
25

0,19
0,33
0,47
0,61

997 0707 051 05


997 0707 101 05
997 0707 151 05
997 0707 201 05

7 X 0,75
7 G 0,75
7 G 0,75
7 G 0,75

500
1000
1500
2000

1500
3000
4500
6000

7,4
7,4
7,4
7,4

28
28
28
28

0,26
0,54
0,78
1,03

997 0712 051 05


997 0712 101 05

12 G 0,75
12 G 0,75

500
1000

1500
3000

10,0
10,0

36
36

0,50
0,91

997 0718 051 05


997 0718 101 05

18 G 0,75
18 G 0,75

500
1000

1500
3000

12,0
12,0

42
42

0,28
1,51

997 1002 051 05


997 1002 101 05
997 1002 151 05
997 1002 201 05

2 X 1,0
2 X 1,0
2 X 1,0
2 X 1,0

500
1000
1500
2000

1500
3000
4500
6000

5,8
5,8
5,8
5,8

20
20
20
20

0,10
0,18
0,24
0,33

997 1003 051 05


997 1003 101 05
997 1003 151 05
997 1003 201 05

3 G 1,0
3 G 1,0
3 G 1,0
3 G 1,0

500
1000
1500
2000

1500
3000
4500
6000

6,2
6,2
6,2
6,2

21
21
21
21

0,14
0,25
0,35
0,46

997 1004 051 05


997 1004 101 05
997 1004 151 05
997 1004 201 05

4 G 1,0
4 G 1,0
4 G 1,0
4 G 1,0

500
1000
1500
2000

1500
3000
4500
6000

6,7
6,7
6,7
6,7

25
25
25
25

0,20
0,35
0,52
0,67

997 1005 051 05


997 1005 101 05
997 1005 151 05
997 1005 201 05

5 G 1,0
5 G 1,0
5 G 1,0
5 G 1,0

500
1000
1500
2000

1500
3000
4500
6000

7,2
7,2
7,2
7,2

25
25
25
25

0,24
0,43
0,62
0,80

Part-No.

No. of cores
+
crosssection

Spiral
length

Extended
length
approx.

Cable
diameter

Spiral
outer

Copper
weight

mm

mm

mm

approx.
mm

kg/piece

997 1007 051 05


997 1007 101 05
997 1007 151 05
997 1007 201 05

7 G 1,0
7 G 1,0
7 G 1,0
7 G 1,0

500
1000
1500
2000

1250
2500
3750
5000

8,2
8,2
8,2
8,2

31,0
31,0
31,0
31,0

0,35
0,64
0,85
1,20

997 1012 051 05


997 1012 101 05

12 G 1,0
12 G 1,0

500
1000

1500
3000

11,0
11,0

40,0
45,0

0,58
1,05

997 1018 051 05


997 1018 101 05

18 G 1,0
18 G 1,0

500
1000

1500
3000

13,0
13,0

45,0
45,0

0,90
1,65

997 1502 051 05


997 1502 101 05
997 1502 151 05
997 1502 201 05

2 X 1,5
2 X 1,5
2 X 1,5
2 X 1,5

500
1000
1500
2000

1500
3000
4500
6000

6,5
6,5
6,5
6,5

25,0
25,0
25,0
25,0

0,15
0,27
0,40
0,52

997 1503 051 05


997 1503 101 05
997 1503 151 05
997 1503 201 05

3 G 1,5
3 G 1,5
3 G 1,5
3 G 1,5

500
1000
1500
2000

1500
3000
4500
6000

6,9
6,9
6,9
6,9

25,0
25,0
25,0
25,0

0,22
0,40
0,57
0,74

997 1505 051 05


997 1505 101 05
997 1505 151 05
997 1505 201 05

5 G 1,5
5 G 1,5
5 G 1,5
5 G 1,5

500
1000
1500
2000

1250
2500
3750
5000

8,3
8,3
8,3
8,3

30,0
30,0
30,0
30,0

0,35
0,64
0,92
1,19

997 1507 051 05


997 1507 101 05
997 1507 151 05
997 1507 201 05

7 G 1,5
7 G 1,5
7 G 1,5
7 G 1,5

500
1000
1500
2000

1250
2500
3750
5000

9,0
9,0
9,0
9,0

32,0
32,0
32,0
32,0

0,50
0,86
1,25
1,63

997 1512 051 05


997 1512 101 05

12 G 1,5
12 G 1,5

500
1000

1500
3000

12,0
12,0

47,0
47,0

0,98
1,76

997 1518 051 05


997 1518 101 05

18 G 1,5
18 G 1,5

500
1000

1500
3000

13,5
13,5

53,0
53,0

1,31
2,40

997 2503 051 05


997 2503 101 05
997 2503 151 05
997 2503 201 05

3 G 2,5
3 G 2,5
3 G 2,5
3 G 2,5

500
1000
1500
2000

1250
2500
3750
5000

8,3
8,3
8,3
8,3

28,7
28,7
28,7
28,7

0,36
0,65
0,93
1,22

997 2505 051 05


997 2505 101 05
997 2505 151 05
997 2505 201 05

5 G 2,5
5 G 2,5
5 G 2,5
5 G 2,5

500
1000
1500
2000

1250
2500
3750
5000

10,0
10,0
10,0
10,0

38,0
38,0
38,0
38,0

0,63
1,15
1,65
2,15

Other dimensions on request

ConCab kabel connects the world

243

CC-control cable yellow PUR-JB-147


Coloured cores with / without protective conductor
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 147 5G1,5 JB

The oil resistant CC-PUR-JB-147 is suitable as a


control cable and safety cable applied in machine tool,
connection and extention cable for hand-held devices.
It is designed to be used indoors and outdoors and is
particularly suitable where aggressive
substances like mineral oil occur or when it has to
undergo rough mechanical abrasion.
The polyurethane outer sheath fulfils
the highest demands of wear and tear as well as
impact requirements.

Construction
Fine strands of bare copper wire
with PVC core insulation.
Coloured cores acc. to DIN VDE 0293 or
DIN VDE 0293 part 308. Cores twisted in layers.
PUR outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482 ,part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour yellow (RAL 1016).
Other sheath colours available on request.

Part-No.

244

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

147 0010 002


147 0010 003

2 X 1,0
3 G 1,0

19,0
29,0

7,1
7,6

67
81

147 0015 003


147 0015 004
147 0015 005

3 G 1,5
4 G 1,5
5 G 1,5

43,0
58,0
72,0

9,2
10,2
10,9

120
160
179

147 0025 003


147 0025 005

3 G 2.5
5 G 2.5

72,0
96,0

10,8
13,6

186
251

Technical data
Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
10 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0282

ConCab kabel connects the world

CC-appliance cable H05BQ-F-140


H07BQ-F-140
EPR insulation, flexible cable, polyurethane sheath
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 140 5G1,5 H07BQ-F

Technical data
Rated voltage:
H05BQ-F: 300/500 V
H07BQ-F: 450/750 V
Test voltage:
H05BQ-F:
2000 V
H07BQ-F:
2500 V
The CC-appliance cable H05BQ-F-140
resp. H07BQ-F-140 is suitable for electrical tools,
heating appliances, lights, transportable building site
machines and similar ones for agriculture, shipyards
and container railway stations. The polyurethane
sheath is resistant to cutting and abrasion. It can be
used in dry, damp and wet rooms as well as outside. It
is extremely resistant to oils, fats, acids and alkalines.

Construction
Fine strands of bare copper wire with rubber core
insulation. Coloured cores acc. to DIN VDE 0293,
part 308. Cores twisted in layers.
Weather resistant PUR outer sheath.
Colour orange (RAL 2003).

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-50C to +90C
-40C to +90C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 12 X cable diameter

ConCab kabel connects the world

Approvals:
DIN VDE 0282, part 10

245

CC-appliance cable H05BQ-F-140


H07BQ-F-140
EPR insulation, flexible cable, polyurethane sheath
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

140 0007 002


140 0007 003
140 0007 004
140 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
29,0
36,0

5,7 6,2 6,8 7,6 -

7,4
8,1
8,8
9,9

60
70
85
105

140 0010 002


140 0010 003
140 0010 004
140 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,2
29,0
38,4
48,0

6,1 - 8,0
6,5 - 8,5
7,1 - 9,3
8,0 - 10,3

70
80
100
120

140 0015 002


140 0015 003
140 0015 004
140 0015 005

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

29,0
43,0
58,0
72,0

7,6 - 9,8
8,0 - 10,4
9,0 - 11,6
9,8 - 12,7

97
120
150
180

140 0025 002


140 0025 003
140 0025 004
140 0025 005

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5

48,0
72,0
96,0
120,0

9,0 - 11,6
9,6 - 12,4
10,7 - 13,8
11,9 - 15,3

110
175
230
280

140 0040 002


140 0040 003
140 0040 004
140 0040 005

2X4
3G4
4G4
5G4

77,0
115,0
154,0
192,0

10,6 - 13,7
11,3 - 14,5
12,7 - 16,2
14,1 - 17,9

196
225
320
420

140 0060 002


140 0060 003
140 0060 004
140 0060 005

2X6
3G6
4G6
5G6

115,0
173,0
230,0
288,0

11,8 - 15,1
12,8 - 16,3
14,2 - 18,1
15,7 - 20,0

315
325
495
585

140 0100 002


140 0100 003
140 0100 004
140 0100 005

2 X 10
3 G 10
4 G 10
5 G 10

192,0
288,0
384,0
480,0

15,6 - 19,9
16,8 - 21,4
18,6 - 23,6
20,4 - 25,9

430
640
735
970

140 0160 002


140 0160 003
140 0160 004
140 0160 005

2 X 16
3 G 16
4 G 16
5 G 16

308,0
461,0
615,0
768,0

17,9 - 22,8
19,5 - 24,7
21,3 - 27,0
23,7 - 30,0

600
760
1185
1475

from cross section 4,0 mm in acc. to

246

ConCab kabel connects the world

CC-control cable H-1110


Halogen-free, numbered black cores
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 1110 4G1,5 JZ

Technical data
Rated voltage:
300/500 V
The CC-control cable H-1110 is suitable as
a control, regulating and measuring cable where free,
unrestricted movement is required.
It is used in machine tool, plant and apparatus
construction, heating, air conditioning and ventilation
technology and for other applications in electrical
equipment particularly where an increased demand for
protection against fire for humans,
goods and premises is.

Construction
Fine strands of bare copper wire with halogen-free
polymere mixture insulation. Cores black with
consecutive white numbering. 3 cores or more with
protective green/yellow conductor in the outer layer.
Cores twisted in layers. Outer sheath of halogen-free
polymere mixture, flame retardant
(acc. to IEC 60332-3).
Colour grey (RAL 7001 or 7035).

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

Approvals:
acc. to DIN VDE 0245, 02500281, 0282
CEI: 20.22

ConCab kabel connects the world

247

CC-control cable H-1110


Halogen-free, numbered black cores
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

1 110 0005 002 5


1 110 0005 003 5
1 112 0005 003 5
1 110 0005 004 5
1 112 0005 004 5
1 110 0005 005 5
1 112 0005 005 5
1 110 0005 007 5
1 112 0005 007 5
1 110 0005 008 5
1 110 0005 010 5
1 110 0005 012 5
1 110 0005 018 5
1 110 0005 020 5
1 110 0005 025 5
1 110 0005 030 5
1 110 0005 034 5

2 X 0,5
3 G 0,5
3 X 0,5
4 G 0,5
4 X 0,5
5 G 0,5
5 X 0,5
7 G 0,5
7 X 0,5
8 G 0,5
10 G 0,5
12 G 0,5
18 G 0,5
20 G 0,5
25 G 0,5
30 G 0,5
34 G 0,5

9,6
14,4
witho.gnye
19,2
witho.gnye
24,0
witho.gnye
34,0
witho.gnye
38,4
48,0
58,0
86,4
96,0
120,0
144.0
163,2

4,8
5,1
5,1
5,7
5,7
6,2
6,2
6,7
6,7
8,0
8,6
8,9
10,5
11,4
12,4
13,3
14,5

43
55
55
63
63
74
74
95
95
111
131
163
245
286
314
364
406

1 110 0007 002 5


1 110 0007 003 5
1 112 0007 003 5
1 110 0007 004 5
1 112 0007 004 5
1 110 0007 005 5
1 112 0007 005 5
1 110 0007 007 5
1 112 0007 007 5
1 110 0007 009 5
1 110 0007 010 5
1 110 0007 012 5
1 110 0007 016 5
1 110 0007 018 5
1 110 0007 020 5
1 110 0007 025 5
1 110 0007 034 5

2 X 0,75
3 G 0,75
3 X 0,75
4 G 0,75
4 X 0,75
5 G 0,75
5 X 0,75
7 G 0,75
7 X 0,75
9 G 0,75
10 G 0,75
12 G 0,75
16 G 0,75
18 G 0,75
20 G 0.75
25 G 0,75
34 G 0,75

14,4
21,6
witho.gnye
29,0
witho.gnye
36,0
witho.gnye
50,0
witho.gnye
64,8
72,0
86,0
115,0
130,0
144,0
180,0
245,0

5,4
5,7
5,7
6,2
6,2
6,7
6,7
7,3
7,3
9,4
9,6
9,9
11,1
11,7
12,6
13,8
15,9

55
65
65
83
83
98
98
115
115
153
165
185
255
305
375
440
530

248

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

1 110 0010 002 5


1 110 0010 003 5
1 112 0010 003 5
1 110 0010 004 5
1 112 0010 004 5
1 110 0010 005 5
1 112 0010 005 5
1 110 0010 007 5
1 112 0010 007 5
1 110 0010 008 5
1 110 0010 010 5
1 110 0010 012 5
1 110 0010 016 5
1 110 0010 018 5
1 110 0010 020 5
1 110 0010 025 5
1 110 0010 034 5
1 110 0010 041 5
1 110 0010 042 5
1 110 0010 050 5
1 110 0010 061 5
1 110 0010 065 5

2 X 1,0
3 G 1,0
3 X 1,0
4 G 1,0
4 X 1,0
5 G 1,0
5 X 1,0
7 G 1,0
7 X 1,0
8 G 1,0
10 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
20 G 1,0
25 G 1,0
34 G 1,0
41 G 1,0
42 G 1,0
50 G 1,0
61 G 1,0
65 G 1,0

19,2
29,0
witho.gnye
38,4
witho.gnye
48,0
witho.gnye
67,0
witho.gnye
77,0
96,0
115,0
154,0
173,0
192,0
240,0
326,0
394,0
403,0
480,0
586,0
624,0

5,7
6,0
6,0
6,5
6,5
7,1
7,1
8,0
8,0
9,5
10,2
10,5
11,8
12,7
13,4
14,7
17,1
21,4
21,4
24,0
25,5
27,1

56
75
75
87
87
101
101
129
129
171
225
245
305
310
370
455
730
815
815
895
1005
1170

1 110 0015 002 5


1 110 0015 003 5
1 112 0015 003 5
1 110 0015 004 5
1 112 0015 004 5
1 110 0015 005 5
1 112 0015 005 5
1 110 0015 007 5
1 112 0015 007 5
1 110 0015 008 5
1 110 0015 010 5
1 110 0015 012 5
1 110 0015 016 5
1 110 0015 018 5
1 110 0015 020 5
1 110 0015 025 5
1 110 0015 034 5
1 110 0015 042 5
1 110 0015 050 5
1 110 0015 061 5
1 110 0015 065 5

2 X 1,5
3 G 1,5
3 X 1,5
4 G 1,5
4 X 1,5
5 G 1,5
5 X 1,5
7 G 1,5
7 X 1,5
8 G 1,5
10 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
20 G 1,5
25 G 1,5
34 G 1,5
42 G 1,5
50 G 1,5
61 G 1,5
65 G 1,5

29,0
43,0
witho.gnye
58,0
witho.gnye
72,0
witho.gnye
101,0
witho.gnye
115,0
144,0
173,0
230,0
259,0
288,0
360,0
490,0
605,0
720,0
878,0
936,0

6,3
6,7
6,7
7,2
7,2
8,1
8,1
8,9
8,9
10,6
11,6
12,0
13,4
14,4
15,4
16,9
19,4
23,1
21,9
27,9
30,0

87
107
107
142
142
187
187
174
174
305
325
345
410
510
600
695
1005
1210
1410
1650
1830

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

1 110 0025 002 5


1 110 0025 003 5
1 110 0025 004 5
1 110 0025 005 5
1 110 0025 007 5
1 110 0025 012 5
1 110 0025 018 5
1 110 0025 025 5

2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
18 G 2.5
25 G 2.5

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0

7,5
8,1
8,9
10,0
11,1
14,8
17,8
20,8

133
162
202
220
270
554
698
923

1 110 0040 002 5


1 110 0040 003 5
1 110 0040 004 5
1 110 0040 005 5
1 110 0040 007 5
1 110 0040 012 5

2X4
3G4
4G4
5G4
7G4
12 G 4

76,8
115,2
154,0
192,0
269,0
461,0

9,5
9,9
10,8
12,1
13,4
19,8

176
256
336
412
492
932

1 110 0060 003 5


1 110 0060 004 5
1 110 0060 005 5
1 110 0060 007 5

3G6
4G6
5G6
7G6

173,0
230,0
288,0
403,0

11,7
13,0
14,5
16,0

287
386
500
740

1 110 0100 003 5


1 110 0100 004 5
1 110 0100 005 5
1 110 0100 007 5

3 G 10
4 G 10
5 G 10
7 G 10

288,0
384,0
480,0
672,0

14,6
16,2
18,1
20,0

622
782
992
1312

1 110 0160 003 5


1 110 0160 004 5
1 110 0160 005 5
1 110 0160 007 5

3 G 16
4 G 16
5 G 16
7 G 16

461,0
614,0
768,0
1075,0

18,8
21,2
21,2
23,4

872
1212
1545
1850

ConCab kabel connects the world

249

CC-control cable H-CH-1130


Halogen-free numbered black cores, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 1130 3G1,5 JZ-C

Technical data
Rated voltage:
300/500 V
The CC-control cable H-CH-1130 shielded is suitable
as a control, regulating and measuring cable
especially where free unrestricted movement is
required and where an increased demand for
electromagnetic compatibility (EMC) is. It is used in
machine tools, plant and apparatus construction,
heating, air conditioning and ventilation technology
and for other applications of electrical
equipment, particularly if there is an increased
demand for protection against fire for humans, goods
and premises.

Construction
Fine strands of bare copper wire with halogen-free
polymer mixture insulation. Cores black with
consecutive white numbering. 3 cores or more with
protective green/yellow conductor in the outer layer.
Cores twisted in layers. Separation foil, tinned copper
shield. Outer sheath of halogen-free polymer mixture,
flame retardant (acc. to IEC 60332-3).
Colour grey (RAL 7001 or 7035).

250

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
6 X cable diameter
20 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250,
0281, 0282
CEI: 20.22

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

1 130 0005 002 5 2 X 0,5


1 130 0005 003 5 3 G 0,5
1 130 0005 004 5 4 G 0,5
1 130 0005 005 5 5 G 0,5
1 130 0005 007 5 7 G 0,5
1 130 0005 012 5 12 G 0,5
1 130 0005 018 5 18 G 0,5
1 130 0005 025 5 25 G 0,5

29
39
49
57
69
107
141
211

5,8
6,1
6,5
7,0
7,5
9,9
11,5
13,4

51
61
72
85
105
170
236
345

1 130 0007 002 5 2 X 0,75


1 130 0007 003 5 3 G 0,75
1 130 0007 004 5 4 G 0,75
1 130 0007 005 5 5 G 0,75
1 130 0007 007 5 7 G 0,75
1 130 0007 012 5 12 G 0,75
1 130 0007 018 5 18 G 0,75
1 130 0007 025 5 25 G 0,75

43
52
61
72
90
148
211
280

6,2
6,5
7,0
7,7
8,3
10,9
12,7
14,8

60
77
87
106
140
220
315
435

1 130 0010 002 5 2 X 1,0


1 130 0010 003 5 3 G 1,0
1 130 0010 004 5 4 G 1,0
1 130 0010 005 5 5 G 1,0
1 130 0010 007 5 7 G 1,0
1 130 0010 012 5 12 G 1,0
1 130 0010 018 5 18 G 1,0
1 130 0010 025 5 25 G 1,0

51
62
74
88
112
190
268
354

6,5
6,8
7,3
8,1
8,8
11,5
13,9
15,9

79
90
110
140
175
285
399
566

1 130 0015 002 5


1 130 0015 003 5
1 130 0015 004 5
1 130 0015 005 5
1 130 0015 007 5
1 130 0015 012 5
1 130 0015 018 5
1 130 0015 025 5
1 130 0015 034 5

65
82
100
119
154
268
373
530
683

7,1
7,5
8,2
8,9
9,9
13,0
15,6
17,9
21,1

91
112
141
170
223
365
512
745
895

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

1 130 0025 002 5 2 X 2.5


1 130 0025 003 5 3 G 2.5
1 130 0025 004 5 4 G 2.5
1 130 0025 005 5 5 G 2.5
1 130 0025 007 5 7 G 2.5
1 130 0025 012 5 12 G 2.5

97
118
147
176
253
385

8,7
8,9
9,9
11,0
11,9
16,0

134
176
210
248
368
598

1 130 0040 002 5


1 130 0040 003 5
1 130 0040 004 5
1 130 0040 005 5
1 130 0040 007 5

2X4
3G4
4G4
5G4
7G4

136
180
248
269
371

10,0
10,5
11,6
12,9
14,4

190
248
333
412
545

1 130 0060 002 5


1 130 0060 003 5
1 130 0060 004 5
1 130 0060 005 5
1 130 0060 007 5

2X6
3G6
4G6
5G6
7G6

176
242
343
443
510

11,7
12,7
14,2
15,5
17,0

270
337
437
530
700

1 130 0100 002 5


1 130 0100 003 5
1 130 0100 004 5
1 130 0100 005 5
1 130 0100 007 5

2 X 10
3 G 10
4 G 10
5 G 10
7 G 10

267
350
535
592
825

15,8
15,6
805
19,5
21,4

425
510
888
1356

1 130 0160 004 5


1 130 0160 005 5

4 G 16
5 G 16

800
1065

20,2
22,6

972
1370

ConCab kabel connects the world

251

CC-control cable H-1111


Halogen-free, coloured cores
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 1111 5G1,5 JB 300/500V

Technical data
Rated voltage:
300/500 V
Test voltage:
4000 V

The CC-control cable H-1111 is suitable as a control,


regulating and measuring cable especially where free
unrestricted movement is required. It is used in
machine tools, plant and apparatus construction,
heating, air conditioning and ventilation technology
and for other applications of electrical equipment,
particularly if an increased demand for protection
against fire for humans, goods and premises is.

Construction
Fine strands of bare copper wire with halogen-free
insulation. Cores coloured acc. to DIN VDE 0293,
part 308. 3 cores or more with protective
green/yellow conductor in the outer layer.
Outer sheath halogen-free, flame retardant polymer
mixture (acc. to IEC 60332-3).
Colour grey (RAL 7001 or 7035).

252

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
Temperature range:
fixed installation:
-40C to +80C
flexible application:
-5C to +70C
Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0245, 0250,
0281, 0282
CEI: 20.22

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg /km

mm

kg /km

1 111 0015 003 5


1 111 0015 004 5
1 111 0015 005 5

3 G 1,5
4 G 1,5
5 G 1,5

43,0
58,0
72,0

7,6
8,2
9,4

107
142
187

1 111 0025 003 5


1 111 0025 004 5
1 111 0025 005 5

3 G 2.5
4 G 2.5
5 G 2.5

72,0
96,0
120,0

9,1
10,1
11,4

162
202
253

1 111 0040 003 5


1 111 0040 004 5
1 111 0040 005 5

3G4
4G4
5G4

115,2
154,0
192,0

10,7
11,9
13,9

256
336
412

1 111 0060 002 5


1 111 0060 004 5
1 111 0060 005 5

2X6
4G6
5G6

115,0
230,0
288,0

10,8
14,0
15,9

178
375
500

1 111 0100 002 5


1 111 0100 004 5
1 111 0100 005 5

2 X 10
4 G 10
5 G 10

192,0
384,0
480,0

13,7
18,1
20,0

287
782
992

1 111 0160 004 5


1 111 0160 005 5

4 G 16
5 G 16

614,0
768,0

20,7
23,9

1212
1545

1 111 0250 004 5


1 111 0250 005 5

4 G 25
5 G 25

960,0
1200,0

25,2
29,2

1581
1921

1 111 0350 004 5


1 111 0350 005 5

4 G 35
5 G 35

1344,0
1680,0

29,5
33,9

2065
2580

1 111 0500 004 5

4 G 50

1920,0

34,8

2820

1 111 0700 004 5

4 G 70

2688,0

41,0

3950

1 111 0950 004 5

4 G 95

3648,0

45,8

4945

1 111 1200 004 5

4 G 120

4608,0

52,0

6400

ConCab kabel connects the world

253

254

255

CC-data cable LiYY-210


Coloured cores acc. to DIN 47100
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 210 25x0,34 LiYY

Technical data
Rated voltage:
up to 0,34 mm2:
300 V
up to 0,34 mm2:

The flexible CC-data cable LiYY-210


is suitable as a control and signal cable in data,
measurement and regulation technology. These cables
are best suited for miniature and sub-miniature
connector systems.

Construction
Fine strands of bare copper wire, PVC core insulation.
Cores coloured acc. to DIN 47100. Cores twisted in
layers, PVC outer sheath, flame retardant and
self- extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere):
Capacity at 800 Hz core/core (approx. nF/km):

256

Test voltage:
1200 V

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

0,14
m 138
2
90

0,25
m 79
4
100

0,34
m 57
6
110

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

210 0001 002


210 0001 003
210 0001 004
210 0001 005
210 0001 006
210 0001 007
210 0001 008
210 0001 009
210 0001 010
210 0001 012
210 0001 014
210 0001 016
210 0001 018
210 0001 020
210 0001 021
210 0001 024
210 0001 025
210 0001 027
210 0001 030
210 0001 032
210 0001 036
210 0001 040
210 0001 044
210 0001 048
210 0001 052
210 0001 056
210 0001 061

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
6 X 0,14
7 X 0,14
8 X 0,14
9 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
16 X 0,14
18 X 0,14
20 X 0,14
21 X 0,14
24 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
44 X 0,14
48 X 0,14
52 X 0,14
56 X 0,14
61 X 0,14

2,7
4,0
5,4
6,7
8,1
9,4
10,8
12,1
13,4
16,1
18,8
21,5
24,2
26,8
28,2
32,3
33,5
36,3
40,3
43,0
48,4
54,0
59,0
65,0
70,0
75,0
82,0

3,2
3,4
3,6
3,9
4,4
4,5
4,7
5,4
5,6
5,8
6,0
6,3
7,1
7,2
7,4
7,6
8,0
8,0
8,2
8,8
9,1
9,5
10,4
10,6
10,8
11,2
11,5

12
15
17
22
25
26
29
32
35
43
48
52
65
73
79
89
93
96
106
112
120
132
145
161
177
185
204

210 0002 002


210 0002 003
210 0002 004
210 0002 005
210 0002 006
210 0002 007
210 0002 008
210 0002 010
210 0002 012
210 0002 014
210 0002 016
210 0002 018
210 0002 020

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
6 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
16 X 0,25
18 X 0,25
20 X 0,25

4,8
7,2
9,6
12,0
14,4
16,8
19,2
24,0
28,8
33,6
38,4
43,2
48,0

3,7
3,9
4,2
4,7
5,2
5,2
5,7
6,8
7,0
7,3
7,7
8,1
8,5

25
29
31
38
42
48
54
65
75
89
95
110
117

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

210 0002 021


210 0002 024
210 0002 025
210 0002 027
210 0002 030
210 0002 032
210 0002 036
210 0002 040
210 0002 044
210 0002 048
210 0002 052
210 0002 061

21 X 0,25
24 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
44 X 0,25
48 X 0,25
52 X 0,25
61 X 0,25

50,0
57,6
60,0
65,0
72,0
77,0
86,0
96,0
106,0
115,0
125,0
146,4

8,5
9,4
9,9
10,0
10,2
10,6
10,9
11,6
12,3
12,5
12,9
13,8

128
143
146
158
172
186
196
207
214
234
258
324

210 0003 002


210 0003 003
210 0003 004
210 0003 005
210 0003 006
210 0003 007
210 0003 008
210 0003 009
210 0003 010
210 0003 012
210 0003 014
210 0003 016
210 0003 018
210 0003 021
210 0003 024
210 0003 025
210 0003 027
210 0003 030
210 0003 032
210 0003 036
210 0003 040
210 0003 044
210 0003 048
210 0003 052
210 0003 056
210 0003 060
210 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
6 X 0,34
7 X 0,34
8 X 0,34
9 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
25 X 0,34
27 X 0,34
30 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
44 X 0,34
48 X 0,34
52 X 0,34
56 X 0,34
60 X 0,34
61 X 0,34

6,5
9,8
13,1
16,3
19,6
22,8
26,1
29,4
32,6
39,2
45,7
52,2
58,8
68,6
78,3
81,6
88,1
97,9
104,4
117,5
130,6
143,6
156,7
169,7
182,8
196,0
199,1

4,3
4,5
4,9
5,6
6,1
6,1
6,7
7,6
7,8
8,0
8,4
9,2
9,6
10,5
11,0
11,6
11,6
12,1
12,5
12,9
13,5
14,4
15,0
15,4
15,9
16,2
16,4

28
30
40
44
53
60
66
76
77
88
101
114
135
151
171
181
188
207
223
244
266
292
315
337
360
380
392

ConCab kabel connects the world

257

CC-data cable LiYY-210


Coloured cores acc. to DIN 47100
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 210 25x0,75 LiYY

Technical data
Rated voltage:
from 0,5 mm2:
300/500 V
from 0,5 mm2:

Test voltage:
2000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
The flexible CC-data cable LiYY-210
is suitable as a control and signal cable in data,
measurement and regulation technology. These cables
are best suited for connector systems.

Construction
Fine strands of bare copper wire. PVC core insulation.
Core colours acc. to DIN 47100. Cores twisted in
layer. PVC outer sheath, flame retardant and
self- extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere):
Capacity at 800 Hz core/core (approx. nF/km):

258

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812

0,5
m 39
9
120

ConCab kabel connects the world

0,75
1,0
1,5
m 26 m 19,5 m 13,3
12
15
18
120
120
120

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

210 0005 002


210 0005 003
210 0005 004
210 0005 005
210 0005 006
210 0005 007
210 0005 008
210 0005 010
210 0005 012
210 0005 014
210 0005 016
210 0005 018
210 0005 020
210 0005 021
210 0005 024
210 0005 027
210 0005 030
210 0005 032
210 0005 036
210 0005 040
210 0005 044
210 0005 052
210 0005 061

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
6 X 0,5
7 X 0,5
8 X 0,5
10 X 0,5
12 X 0,5
14 X 0,5
16 X 0,5
18 X 0,5
20 X 0,5
21 X 0,5
24 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
36 X 0,5
40 X 0,5
44 X 0,5
52 X 0,5
61 X 0,5

9,6
14,4
19,2
24,0
28,8
34,0
38,4
48,0
58,0
67,0
77,0
86,4
96,0
101,0
115,0
130,0
144,0
154,0
173,0
192,0
211,0
250,0
293,0

4,9
5,2
5,8
6,3
7,1
7,1
7,7
9,2
9,4
10,2
10,6
11,3
11,8
13,0
13,1
13,7
14,1
14,7
15,2
16,0
16,8
19,8
20,2

25
35
42
49
65
73
83
120
130
130
152
166
180
185
250
244
267
291
314
345
392
454
536

210 0007 002


210 0007 003
210 0007 004
210 0007 005
210 0007 007
210 0007 008
210 0007 010
210 0007 012
210 0007 016
210 0007 020
210 0007 025
210 0007 030

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
10 X 0,75
12 X 0,75
16 X 0,75
20 X 0,75
25 X 0,75
30 X 0,75

14,4
21,6
28,8
36,0
50,0
58,0
72,0
86,0
115,0
144,0
180,0
216,0

5,4
5,8
6,3
7,1
7,7
8,3
9,8
10,3
11,8
13,0
14,9
15,4

48
57
69
78
112
126
149
176
218
274
285
393

210 0010 002


210 0010 003
210 0010 005

2 X 1,0
3 X 1,0
5 X 1,0

19,2
29,0
48,0

6,0
6,3
7,7

55
70
98

210 0015 002


210 0015 003
210 0015 004

2 X 1,5
3 X 1,5
4 X 1,5

29,0
43,0
58,0

7,2
7,6
8,3

74
89
105

ConCab kabel connects the world

259

CC-data cable LiYY-(TP)-230


Coloured cores acc. to DIN 47100
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 230 2x2x0,34 LIYY (TP)

Technical data

Fine strands of bare copper wire. PVC core insulation.


Cores coloured acc. to DIN 47100. Cores twisted in
short lengths to pairs and pairs twisted in layers, foil.
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Conductor cross-section (mm2):


Loop resistance (Ohm/km):
Max. load (Ampere):
Capacity at 800 Hz core/core (approx. nF/km):
Capacity coupling between pairs
at 800 Hz (approx. pF/100 m):

260

Rated voltage:
300 V
300/500 V

up to 0,34 mm2:
from 0,50 mm2:

Test voltage:
1200 V
2000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands

The flexible CC-data cable LiYY-(TP)-230


is suitable as a control and signal cable in data,
measurement and signal technology.
Synchronized twisted core pair lengths cause
minimum coupling values.

Construction

up to 0,34 mm2:
from 0,50 mm2:

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812, 0814

0,14
0,25 0,34
m 276 m 158 m 114
2
4
6
90
100
110
300

300

ConCab kabel connects the world

300

0,5 0,75
m 78 m 52
9
12
120 120
300

300

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

230 0001 002


230 0001 003
230 0001 004
230 0001 006
230 0001 008
230 0001 010
230 0001 012
230 0001 014
230 0001 016
230 0001 018
230 0001 020
230 0001 024
230 0001 025
230 0001 026
230 0001 028
230 0001 030
230 0001 032
230 0001 036
230 0001 040
230 0001 046
230 0001 050
230 0001 052
230 0001 055

2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
6 X 2 X 0,14
8 X 2 X 0,14
10 X 2 X 0,14
12 X 2 X 0,14
14 X 2 X 0,14
16 X 2 X 0,14
18 X 2 X 0,14
20 X 2 X 0,14
24 X 2 X 0,14
25 X 2 X 0,14
26 X 2 X 0,14
28 X 2 X 0,14
30 X 2 X 0,14
32 X 2 X 0,14
36 X 2 X 0,14
40 X 2 X 0,14
46 X 2 X 0,14
50 X 2 X 0,14
52 X 2 X 0,14
55 X 2 X 0,14

5,4
8,0
10,7
16,1
21,5
26,9
32,3
37,6
43,0
48,4
54,0
65,0
67,0
70,0
75,0
81,0
86,0
97,0
108,0
124,0
134,0
140,0
148,0

5,0
5,4
5,8
6,6
7,6
8,4
8,7
9,4
10,1
10,3
10,7
11,9
12,1
12,2
12,3
12,8
13,1
13,7
14,7
15,7
16,1
16,5
18,0

24
29
41
56
62
76
89
98
112
119
134
162
173
178
184
199
221
232
257
294
342
359
380

230 0002 002


230 0002 003
230 0002 004
230 0002 005
230 0002 006
230 0002 008
230 0002 010
230 0002 012
230 0002 016
230 0002 020
230 0002 024
230 0002 025
230 0002 030
230 0002 032
230 0002 040
230 0002 050

2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
12 X 2 X 0,25
16 X 2 X 0,25
20 X 2 X 0,25
24 X 2 X 0,25
25 X 2 X 0,25
30 X 2 X 0,25
32 X 2 X 0,25
40 X 2 X 0,25
50 X 2 X 0,25

9,6
14,4
21,0
24,0
28,8
38,4
50,0
57,6
76,8
96,0
115,2
120,0
144,0
153,6
192,0
240,0

5,4
5,7
6,8
7,4
7,9
8,8
9,6
10,1
11,7
13,0
14,0
14,5
15,2
15,6
17,3
19,3

38
48
59
60
80
98
115
150
186
209
247
267
295
313
379
481

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

230 0003 002


230 0003 003
230 0003 004
230 0003 005
230 0003 006
230 0003 008
230 0003 010
230 0003 012
230 0003 016
230 0003 020
230 0003 024
230 0003 025
230 0003 030
230 0003 040
230 0003 050

2 X 2 X 0.34
3 X 2 X 0.34
4 X 2 X 0.34
5 X 2 X 0.34
6 X 2 X 0.34
8 X 2 X 0.34
10 X 2 X 0.34
12 X 2 X 0.34
16 X 2 X 0.34
20 X 2 X 0.34
24 X 2 X 0.34
25 X 2 X 0.34
30 X 2 X 0.34
40 X 2 X 0.34
50 X 2 X 0.34

13,2
19,6
27,2
36,2
39,3
52,2
65,3
78,3
104,4
130,6
156,7
163,2
195,8
261,1
326,4

6,1
7,3
8,0
8,8
10,5
10,5
11,6
12,5
14,4
15,8
17,3
17,8
18,6
21,2
24,8

44
56
69
90
115
129
166
190
240
290
343
372
429
551
698

230 0005 002


230 0005 003
230 0005 004
230 0005 005
230 0005 006
230 0005 008
230 0005 010
230 0005 012
230 0005 016
230 0005 020
230 0005 024
230 0005 025
230 0005 030
230 0005 040
230 0005 050

2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
5 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
25 X 2 X 0,5
30 X 2 X 0,5
40 X 2 X 0,5
50 X 2 X 0,5

19,2
28,8
38,4
48,0
57,6
76,8
96,0
115,2
153,6
192,0
230,4
240,0
288,0
384,0
480,0

7,0
7,8
8,8
9,9
11,0
11,9
12,9
14,1
16,0
18,1
18,7
19,1
21,9
25,1
28,7

72
83
115
120
168
206
247
285
392
373
459
564
553
736
927

28,8
43,2
57,6
86,4
115,2
172,8
230,4

7,9
9,1
10,0
11,8
13,0
15,4
18,1

89
117
146
215
268
402
510

230 0007 002 2 X 2 X 0,75


230 0007 003 3 X 2 X 0,75
230 0007 004 4 X 2 X 0,75
230 0007 006 6 X 2 X 0,75
230 0007 008 8 X 2 X 0,75
230 0007 012 12 X 2 X 0,75
230 0007 016 16 X 2 X 0,75

ConCab kabel connects the world

261

CC-data cable LiYCY-220


Coloured cores acc. to DIN 47100, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 220 12x0,25 LiYCY

Technical data
Rated voltage:
up to 0,34 mm2:
300 V
from 0,50 mm2:
300/500 V
up to 0,34 mm2:
from 0,50 mm2:
The flexible CC-data cable LiYCY-220 is suitable as
a control and signal cable in electronics as well as in
tool and machine construction. A foil wrapping
covering the core reduces the outer diameter which
creates a tighter bending radius and reduced weight in
comparison to usual data cables. The copper shield
means it can be used where an increased demand for
electromagnetic compatibility (EMC) is.

Construction
Fine strands of bare copper wire. PVC core insulation.
Core colours acc. to DIN 47100. Cores twisted in
layers, tinned copper shield. PVC outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere):

262

Test voltage:
1200 V
2000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

Approvals:
acc. to DIN VDE 0281, 0812

0,14
m 138
2

ConCab kabel connects the world

0,25
m 79
4

0,34
m 57
6

0,5
m 39
9

Part-No.

220 0001 001


220 0001 002
220 0001 003
220 0001 004
220 0001 005
220 0001 006
220 0001 007
220 0001 008
220 0001 009
220 0001 010
220 0001 012
220 0001 014
220 0001 015
220 0001 016
220 0001 018
220 0001 020
220 0001 021
220 0001 024
220 0001 025
220 0001 027
220 0001 030
220 0001 032
220 0001 036
220 0001 037
220 0001 040
220 0001 042
220 0001 044
220 0001 048
220 0001 050
220 0001 052
220 0001 056
220 0001 061

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

1 X 0,14
2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
6 X 0,14
7 X 0,14
8 X 0,14
9 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
15 X 0,14
16 X 0,14
18 X 0,14
20 X 0,14
21 X 0,14
24 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
37 X 0,14
40 X 0,14
42 X 0,14
44 X 0,14
48 X 0,14
50 X 0,14
52 X 0,14
56 X 0,14
61 X 0,14

7,0
12,6
14,1
15,9
19,5
22,0
24,0
26,0
28,0
31,2
32,0
35,0
40,0
49,0
54,0
58,0
60,0
74,0
78,0
85,0
98,0
108,0
117,0
120,0
126,0
132,0
138,0
145,0
150,0
155,0
166,0
176,0

2,6
3,7
4,1
4,1
4,6
4,7
4,7
5,0
5,5
5,9
6,1
6,7
6,8
6,8
7,4
7,7
7,4
8,1
8,3
8,8
9,0
9,3
9,6
9,6
9,4
10,2
10,8
11,1
11,1
11,1
11,7
12,0

15
21
25
29
35
38
41
45
49
56
61
66
78
81
93
95
106
118
120
122
129
138
148
159
166
173
181
192
196
212
212
243

Part-No.

220 0002 001


220 0002 002
220 0002 003
220 0002 004
220 0002 005
220 0002 006
220 0002 007
220 0002 008
220 0002 010
220 0002 012
220 0002 014
220 0002 015
220 0002 016
220 0002 018
220 0002 021
220 0002 024
220 0002 025
220 0002 027
220 0002 030
220 0002 032
220 0002 036
220 0002 040
220 0002 042
220 0002 044
220 0002 048
220 0002 050
220 0002 052
220 0002 056
220 0002 061

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

1 X 0,25
2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
6 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
15 X 0,25
16 X 0,25
18 X 0,25
21 X 0,25
24 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
42 X 0,25
44 X 0,25
48 X 0,25
50 X 0,25
52 X 0,25
56 X 0,25
61 X 0,25

8,1
15,0
18,0
22,0
25,0
30,0
32,0
35,0
42,0
50,0
64,0
67,0
71,0
80,0
105,0
115,0
117,0
120,0
132,0
138,0
152,0
164,0
172,0
180,0
209,0
220,0
234,0
259,0
287,0

3,1
4,3
4,5
4,8
5,2
5,8
5,8
6,2
7,3
7,5
8,1
8,1
8,2
8,6
9,0
10,1
10,7
10,3
11,5
11,4
11,8
12,2
13,1
13,1
13,3
13,6
13,6
14,0
14,8

17
20
35
44
50
58
60
67
81
91
116
125
133
137
171
185
190
200
214
227
250
269
284
300
310
325
340
360
385

ConCab kabel connects the world

263

CC-data cable LiYCY-220


Coloured cores according to DIN 47100, shielded
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

220 0003 002


220 0003 003
220 0003 004
220 0003 005
220 0003 006
220 0003 007
220 0003 008
220 0003 010
220 0003 012
220 0003 014
220 0003 016
220 0003 018
220 0003 021
220 0003 024
220 0003 025
220 0003 027
220 0003 032
220 0003 036
220 0003 040
220 0003 042
220 0003 044
220 0003 050
220 0003 052
220 0003 052
220 0005 000
220 0005 002
220 0005 003
220 0005 004
220 0005 005
220 0005 006
220 0005 007
220 0005 008
220 0005 010
220 0005 012
220 0005 016
220 0005 018
220 0005 020
220 0005 024
220 0005 025
220 0005 027
220 0005 030
220 0005 032
220 0005 037
220 0005 040
220 0005 050
220 0005 061

264

No. of
cores
+
crosssection
2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
6 X 0,34
7 X 0,34
8 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
25 X 0,34
27 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
42 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34
1 X 0,5
2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
6 X 0,5
7 X 0,5
8 X 0,5
10 X 0,5
12 X 0,5
16 X 0,5
18 X 0,5
20 X 0,5
24 X 0,5
25 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
37 X 0,5
40 X 0,5
50 X 0,5
61 X 0,5

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

17,0
21,0
25,0
30,0
36,0
42,0
45,0
63,0
70,0
86,0
87,0
108,0
127,0
140,0
144,0
151,0
171,0
188,0
208,0
215,0
223,0
266,0
273,0
316,0
15,0
29,0
35,0
45,0
50,0
59,0
68,0
75,0
93,0
107,0
129,0
152,0
165,0
190,0
211,0
221,0
225,0
258,0
275,0
290,0
340,0
415,0

4,7
4,9
5,5
6,0
6,4
6,4
7,1
8,1
8,3
9,2
9,2
10,2
10,7
11,7
11,9
12,4
12,8
13,2
13,7
14,2
15,3
15,7
16,2
16,8
3,4
5,2
5,7
6,3
6,8
7,6
7,4
7,9
9,1
9,4
10,9
11,9
12,0
13,6
13,5
13,9
14,6
15,3
16,2
16,9
19,0
20,8

33
41
48
58
64
70
93
110
120
137
147
172
196
229
220
258
275
295
331
377
386
435
449
455
24
42
55
68
82
104
109
123
135
160
210
215
270
298
335
331
343
373
405
520
552
659

ConCab kabel connects the world

CC-data cable LiYCY-220


Coloured cores acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 220 12x0,75 LiYCY

Technical data
Rated voltage:
300/500 V
The flexible CC-data cable LiYCY-220 shielded is
suitable as a control and signal cable in electronics as
well as in tool and machine construction. Foil
wrapping over the core reduces the outer diameter and
creates a tighter bending radius and reduces
the weight in comparison to usual data cables. The
copper shield means that it can be used where an
increased demand for greater electromagnetic
compatibility (EMC) is.

Construction
Fine strands of bare copper wire. PVC core insulation.
Core colours acc. to DIN 47100. Cores twisted in
layers, tinned copper shield. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere):

Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
fin. 20 MOhm X km
Temperature range:
fixed installation:
-30C to +80C
flexible application:
-5C to +70C
Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812

0,75
1,0
1,5
m 26 m 19,5 m 13,3
12
15
18

ConCab kabel connects the world

2,5
m 7,98
26

265

CC-data cable LiYCY-220


Coloured cores acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

266

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

220 0007 001


220 0007 002
220 0007 003
220 0007 004
220 0007 005
220 0007 006
220 0007 007
220 0007 008
220 0007 010
220 0007 012
220 0007 014
220 0007 016
220 0007 018
220 0007 020
220 0007 025
220 0007 027
220 0007 030
220 0007 032
220 0007 036
220 0007 042
220 0007 050
220 0007 061

1 X 0,75
2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
6 X 0,75
7 X 0,75
8 X 0,75
10 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75
18 X 0,75
20 X 0,75
25 X 0,75
27 X 0,75
30 X 0,75
32 X 0,75
36 X 0,75
42 X 0,75
50 X 0,75
61 X 0,75

18,0
38,0
49,0
58,0
70,0
96,0
100,0
110,0
131,0
154,0
167,0
183,0
205,0
220,0
250,0
275,0
315,0
330,0
370,0
440,0
480,0
555,0

3,7
6,1
6,4
7,0
7,7
8,3
8,3
9,1
10,4
10,9
11,7
12,3
12,7
13,5
15,7
15,7
16,1
16,1
17,7
20,1
21,0
23,7

30
56
75
95
130
155
168
173
195
232
260
296
315
364
418
485
500
520
606
693
807
942

220 0010 001


220 0010 002
220 0010 003
220 0010 004
220 0010 005
220 0010 006
220 0010 007
220 0010 008
220 0010 010
220 0010 012
220 0010 014
220 0010 016
220 0010 018
220 0010 020
220 0010 025
220 0010 030
220 0010 034
220 0010 040
220 0010 042
220 0010 050
220 0010 061

1 X 1,0
2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0
8 X 1,0
10 X 1,0
12 X 1,0
14 X 1,0
16 X 1,0
18 X 1,0
20 X 1,0
25 X 1,0
30 X 1,0
34 X 1,0
40 X 1,0
42 X 1,0
50 X 1,0
61 X 1,0

23,0
55,0
70,0
80,0
95,0
105,0
120,0
130,0
165,0
185,0
205,0
220,0
248,0
270,0
336,0
395,0
440,0
510,0
533,0
625,0
710,0

4,6
6,6
6,9
7,6
8,2
9,2
9,2
10,1
11,6
11,9
12,7
13,1
13,9
14,8
17,1
17,8
21,5
23,2
23,2
24,7
27,3

44
84
110
130
156
178
192
223
251
265
272
361
380
388
475
554
629
709
769
995
1100

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

220 0015 001


220 0015 002
220 0015 003
220 0015 004
220 0015 005
220 0015 006
220 0015 007
220 0015 008
220 0015 010
220 0015 012
220 0015 014
220 0015 018
220 0015 020
220 0015 025
220 0015 030
220 0015 035
220 0015 042
220 0015 050
220 0015 061

1 X 1,5
2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5
8 X 1,5
10 X 1,5
12 X 1,5
14 X 1,5
18 X 1,5
20 X 1,5
25 X 1,5
30 X 1,5
35 X 1,5
42 X 1,5
50 X 1,5
61 X 1,5

29,0
65,0
90,0
110,0
125,0
144,0
159,0
175,0
210,0
245,0
280,0
345,0
375,0
465,0
555,0
618,0
782,0
885,0
1120,0

4,9
7,8
8,1
8,9
9,7
10,7
10,7
11,7
13,6
14,0
15,4
16,9
17,8
20,1
20,7
23,3
25,5
27,4
29,1

49
97
125
165
193
219
245
270
338
365
410
553
635
720
776
900
1140
1330
1650

220 0025 001


220 0025 002
220 0025 003
220 0025 004
220 0025 005
220 0025 007

1 X 2,5
2 X 2,5
3 X 2,5
4 X 2,5
5 X 2,5
7 X 2,5

65,0
98,0
124,0
150,0
180,0
235,0

5,8
8,6
9,5
10,2
11,5
13,5

95
148
188
236
270
340

ConCab kabel connects the world

267

CC-data cable LiYCY-220


Coloured cores acc. to DIN 47100, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 220 12x0,25 E172073 CUS AWM STYLE 2464 300V 80C

Technical data
Rated voltage:
DIN VDE/IEC:
300 V
UL/CSA:
300 V
Test voltage:
1500 V

The flexible CC-data cable LiYCY-220 UL/CSA, is


suitable as a control and signal cable in electronics as
well as in tool and machine construction. Foil
wrapping covering the core reduces the outer diameter
which creates a tighter bending radius and reduces
weight in comparison to usual data cables. The copper
shield means it can be used where an increased
demand for electromagnetic compatibility (EMC) is.

Construction
Fine strands of bare copper wire. PVC core insulation.
Core colours acc. to DIN 47100. Cores twisted in
layers, tinned copper shield. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere):

268

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 20 MOhm X km
Temperature range:
fixed installation:
-30C to + 80C
flexible application:
-5C to + 70C
Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812
UL: Style 2464
CSA: AWM I/II A/B FT1

0,14
138
2

ConCab kabel connects the world

0,25
79
4

0,34
57
6

No. of cores

No. of cores

+
crosssection

220 26 02
220 26 03
220 26 04
220 26 05
220 26 07
220 26 08
220 26 12
220 26 16
220 26 21
220 26 25

Part-No.

Copper
weight

Outer
diameter
approx.

Weight

AWG

kg/km

mm

kg/km

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
8 X 0,14
12 X 0,14
16 X 0,14
21 X 0,14
25 X 0,14

2 X AWG 26
3 X AWG 26
4 X AWG 26
5 X AWG 26
7 X AWG 26
8 X AWG 26
12 X AWG 26
16 X AWG 26
21 X AWG 26
25 X AWG 26

12,6
14,1
15,9
19,5
24,0
26,0
32,0
49,0
60,0
77,0

3,9
4,1
4,3
4,6
5,0
5,4
6,2
7,1
7,7
8,8

21
25
29
35
40
44
60
74
105
111

220 24 02
220 24 03
220 24 04
220 24 05
220 24 07
220 24 08
220 24 12
220 24 16
220 24 21
220 24 25

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
8 X 0,25
12 X 0,25
16 X 0,25
21 X 0,25
25 X 0,25

2 X AWG 24
3 X AWG 24
4 X AWG 24
5 X AWG 24
7 X AWG 24
8 X AWG 24
12 X AWG 24
16 X AWG 24
21 X AWG 24
25 X AWG 24

16,0
21,0
24,0
29,0
37,0
42,0
50,0
71,0
105,0
117,0

4,5
4,7
5,0
5,5
5,9
6,3
7,6
8,3
9,1
10,3

29
35
44
50
60
67
91
133
171
190

220 22 02
220 22 03
220 22 04
220 22 05
220 22 07
220 22 12
220 22 16
220 22 21
220 22 25

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
12 X 0,34
16 X 0,34
21 X 0,34
25 X 0,34

2 X AWG 22
3 X AWG 22
4 X AWG 22
5 X AWG 22
7 X AWG 22
12 X AWG 22
16 X AWG 22
21 X AWG 22
25 X AWG 22

21,0
27,0
33,0
36,0
51,0
80,0
94,0
127,0
143,0

5,0
5,2
5,6
6,2
6,9
8,7
9,6
10,6
12,4

33
41
48
58
70
120
152
202
254

ConCab kabel connects the world

269

CC-data cable LiYCY-JZ-226


Numbered black cores with protective conductor, shielded
Conforms to the EUlow voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 226 3x1,5 LiYCY-JZ

Technical data
Rated voltage:
300/500 V
The flexible CC-data cable LiYCY-JZ-226 shielded is
suitable as a control and supply cable in electronics as
well as in tool and machine construction. Foil
wrapping over the core reduces the outer diameter
and creates a tighter bending radius and reduces the
weight in comparison to usual control cables. The
copper shield enables it to be used where a greater
electromagnetic compatibility (EMC) is required.

Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire, PVC core
insulation. Black cores with consecutive white
numbering. 3 cores or more with green/yellow
protective conductor in the outer layer. Cores twisted
in layers, foil wrapping. Overall tinned copper shield.
PVC outer sheath, flame retardant and
self- extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp.EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm):


Conductor ressistance (Ohm/km):
Max. load (Ampere): *
* acc. to DINVDE0298 part 4

270

0,5
m39
9

0,75

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812

2,5

4,0

m26 m19,5 m13,3 m7,89

m4,95

12

1,0
15

1,5
18

26

ConCab kabel connects the world

34

6,0

10,0

m3,3 m1,91
44

61

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

226 0005 002


226 0005 003
226 0005 004
226 0005 005
226 0005 006
226 0005 007
226 0005 008
226 0005 010
226 0005 012
226 0005 016
226 0005 018
226 0005 020
226 0005 024
226 0005 025
226 0005 030
226 0005 040
226 0005 050
226 0005 061

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
6 G 0,5
7 G 0,5
8 G 0,5
10 G 0,5
12 G 0,5
16 G 0,5
18 G 0,5
20 G 0,5
24 G 0,5
25 G 0,5
30 G 0,5
40 G 0,5
50 G 0,5
61 G 0,5

29,0
38,0
45,0
57,0
68,0
80,0
85,0
100,0
112,0
140,0
152,0
165,0
190,0
211,0
230,0
298,0
340,0
415,0

5,7
5,9
6,4
7,0
7,7
7,7
8,3
9,6
9,9
11,5
11,9
12,4
13,6
13,9
14,5
16,9
19,0
20,8

42
51
61
76
94
98
111
141
156
195
215
247
298
314
348
440
552
659

226 0007 002


226 0007 003
226 0007 004
226 0007 005
226 0007 006
226 0007 007
226 0007 008
226 0007 010
226 0007 012
226 0007 014
226 0007 016
226 0007 018
226 0007 020
226 0007 024
226 0007 025
226 0007 030
226 0007 032
226 0007 036
226 0007 040
226 0007 042
226 0007 050
226 0007 061

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
6 G 0,75
7 G 0,75
8 G 0,75
10 G 0,75
12 G 0,75
14 G 0,75
16 G 0,75
18 G 0,75
20 G 0,75
24 G 0,75
25 G 0,75
30 G 0,75
32 G 0,75
36 G 0,75
40 G 0,75
42 G 0,75
50 G 0,75
61 G 0,75

38,0
49,0
58,0
70,0
96,0
100,0
110,0
131,0
154,0
167,0
183,0
205,0
220,0
246,0
250,0
315,0
330,0
370,0
395,0
440,0
480,0
555,0

6,1
6,4
7,0
7,7
8,3
8,3
9,1
10,4
10,9
11,7
12,3
12,7
13,5
15,4
15,7
16,1
16,1
17,7
18,6
20,1
21,0
23,7

56
75
95
130
155
168
173
195
232
260
296
315
364
418
429
500
520
606
672
693
807
942

kg/km

ConCab kabel connects the world

271

CC-data cable LiYCY-JZ-226


Numbered black cores with protective conductor, shielded
Conforms to the EU low voltage guideline 73/23/EEC

Part-No.

272

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

226 0010 002


226 0010 003
226 0010 004
226 0010 005
226 0010 006
226 0010 007
226 0010 008
226 0010 010
226 0010 012
226 0010 014
226 0010 016
226 0010 018
226 0010 020
226 0010 024
226 0010 025
226 0010 030
226 0010 034
226 0010 040
226 0010 042
226 0010 050
226 0010 061

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
6 G 1,0
7 G 1,0
8 G 1,0
10 G 1,0
12 G 1,0
14 G 1,0
16 G 1,0
18 G 1,0
20 G 1,0
24 G 1,0
25 G 1,0
30 G 1,0
34 G 1,0
40 G 1,0
42 G 1,0
50 G 1,0
61 G 1,0

55,0
70,0
80,0
95,0
105,0
120,0
130,0
165,0
185,0
205,0
220,0
248,0
270,0
320,0
336,0
395,0
440,0
510,0
533,0
625,0
710,0

6,6
6,9
7,6
8,2
9,2
9,2
10,1
11,6
11,9
12,7
13,1
13,9
14,8
16,8
17,1
17,8
21,5
23,2
23,2
24,7
27,3

84
110
130
156
178
192
223
251
265
272
361
380
388
451
475
554
629
709
769
995
1100

226 0015 002


226 0015 003
226 0015 004
226 0015 005
226 0015 006
226 0015 007
226 0015 008
226 0015 010
226 0015 012
226 0015 014
226 0015 016
226 0015 018
226 0015 020
226 0015 024
226 0015 025
226 0015 030
226 0015 035
226 0015 040
226 0015 050
226 0015 061

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
6 G 1,5
7 G 1,5
8 G 1,5
10 G 1,5
12 G 1,5
14 G 1,5
16 G 1,5
18 G 1,5
20 G 1,5
24 G 1,5
25 G 1,5
30 G 1,5
35 G 1,5
40 G 1,5
50 G 1,5
61 G 1,5

65,0
90,0
110,0
125,0
144,0
159,0
175,0
210,0
245,0
280,0
315,0
345,0
375,0
448,0
465,0
555,0
618,0
732,0
885,0
1120,0

7,8
8,1
8,9
9,7
10,7
10,7
11,7
13,6
14,0
15,4
16,1
16,9
17,8
20,0
20,0
20,7
23,3
25,5
27,4
29,1

97
125
165
193
219
245
270
338
365
410
465
553
635
705
720
776
900
1140
1330
1650

kg/km

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

226 0025 002


226 0025 003
226 0025 004
226 0025 005
226 0025 007
226 0025 012

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5

98,0
124,0
150,0
180,0
235,0
386,0

8,6
9,5
10,2
11,5
13,5
16,7

148
188
236
270
340
585

226 0040 002


226 0040 003
226 0040 004
226 0040 005
226 0040 007

2X4
3G4
4G4
5G4
7G4

135,0
178,0
220,0
270,0
355,0

11,0
11,6
13,0
14,5
16,0

194
250
302
370
498

226 0060 002


226 0060 003
226 0060 004
226 0060 005
226 0060 007

2X6
3G6
4G6
5G6
7G6

175,0
240,0
305,0
440,0
505,0

12,1
13,4
15,0
16,5
18,2

251
285
412
505
671

226 0100 002


226 0100 003
226 0100 004
226 0100 005
226 0100 007

2 X 10
3 G 10
4 G 10
5 G 10
7 G 10

265,0
370,0
485,0
714,0
820,0

15,7
16,7
18,4
20,6
22,8

405
485
620
826
1280

kg/km

ConCab kabel connects the world

273

CC-data cable LiYCY-OZ-223


Numbered black cores, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 223 3x1,5 LiYCY-OZ

Technical data
Rated voltage:
300/500 V
The flexible CC-data cable LiYCY-OZ-223 shielded,
is suitable as a control and supply cable in electronics
as well as in tool and machine construction. A foil
wrapping over the core reduces the outer diameter and
creates a tighter bending radius and reduces the
weight in comparison to usual control cables. The
copper shield enables it to be used where a greater
electromagnetic compatibility
(EMC) is required.

Construction
Fine strands of bare copper wire. PVC core insulation.
Black cores with consecutive white numbering. Cores
twisted in layers. Overall tinned copper shield.
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere): *
* acc. to DINVDE0298 part 4

274

Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812

0,75
1,0
1,5
2,5
4,0
m 26 m 19,5 m 13,3 m 7,98 m 4,95
12
15
18
26
34

ConCab kabel connects the world

6,0
10,0
m 3,3 m 1,91
44
61

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

223 0007 002


223 0007 003
223 0007 004
223 0007 005
223 0007 006
223 0007 007
223 0007 008
223 0007 010
223 0007 012
223 0007 014
223 0007 016
223 0007 018
223 0007 020
223 0007 024
223 0007 030
223 0007 032
223 0007 036
223 0007 040
223 0007 042
223 0007 050
223 0007 061

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
6 X 0,75
7 X 0,75
8 X 0,75
10 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75
18 X 0,75
20 X 0,75
24 X 0,75
30 X 0,75
32 X 0,75
36 X 0,75
40 X 0,75
42 X 0,75
50 X 0,75
61 X 0,75

38,0
49,0
58,0
70,0
96,0
100,0
110,0
131,0
154,0
167,0
183,0
205,0
220,0
246,0
315,0
330,0
370,0
395,0
440,0
480,0
555,0

6,1
6,4
7,0
7,7
8,3
8,3
9,1
10,4
10,9
11,7
12,3
12,7
13,5
15,4
16,1
17,1
17,7
18,6
20,1
21,0
23,7

56
75
95
130
155
168
173
195
232
260
296
315
364
418
500
520
606
672
693
807
942

223 0010 002


223 0010 003
223 0010 004
223 0010 005
223 0010 006
223 0010 007
223 0010 008
223 0010 010
223 0010 012
223 0010 014
223 0010 016
223 0010 018
223 0010 020
223 0010 024
223 0010 025
223 0010 030
223 0010 034
223 0010 040
223 0010 042
223 0010 050
223 0010 061

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0
8 X 1,0
10 X 1,0
12 X 1,0
14 X 1,0
16 X 1,0
18 X 1,0
20 X 1,0
24 X 1,0
25 X 1,0
30 X 1,0
34 X 1,0
40 X 1,0
42 X 1,0
50 X 1,0
61 X 1,0

55,0
70,0
80,0
95,0
105,0
120,0
130,0
165,0
185,0
205,0
220,0
248,0
270,0
320,0
336,0
395,0
440,0
510,0
533,0
625,0
710,0

6,6
6,9
7,6
8,2
9,2
9,2
10,1
11,6
11,9
12,7
13,1
13,9
14,8
16,8
17,1
17,8
21,5
23,2
23,2
24,7
27,3

84
110
130
156
178
192
223
251
265
272
361
380
388
451
475
554
629
709
769
995
1100

223 0015 002


223 0015 003
223 0015 004
223 0015 005
223 0015 006
223 0015 007

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

65,0
90,0
110,0
125,0
144,0
159,0

7,8
8,1
8,9
9,7
10,7
10,7

97
125
165
193
219
245

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

223 0015 008


223 0015 010
223 0015 012
223 0015 014
223 0015 016
223 0015 018
223 0015 020
223 0015 024
223 0015 025
223 0015 030
223 0015 034
223 0015 035
223 0015 040
223 0015 050
223 0015 061

8 X 1,5
10 X 1,5
12 X 1,5
14 X 1,5
16 X 1,5
18 X 1,5
20 X 1,5
24 X 1,5
25 X 1,5
30 X 1,5
34 X 1,5
35 X 1,5
40 X 1,5
50 X 1,5
61 X 1,5

175,0
210,0
245,0
280,0
315,0
345,0
375,0
448,0
465,0
555,0
598,0
618,0
732,0
885,0
1120,0

11,7
13,6
14,0
15,4
16,1
16,9
17,8
20,0
20,0
20,7
21,5
23,3
25,5
27,4
29,1

270
338
365
410
465
553
635
705
720
776
896
900
1140
1330
1650

223 0025 002


223 0025 003
223 0025 004
223 0025 005
223 0025 007
223 0025 012

2 X 2,5
3 X 2,5
4 X 2,5
5 X 2,5
7 X 2,5
12 X 2,5

98,0
124,0
150,0
180,0
235,0
386,0

8,6
9,5
10,2
11,5
13,5
16,7

148
188
236
270
340
585

223 0040 002


223 0040 003
223 0040 004
223 0040 005
223 0040 007

2X4
3X4
4X4
5X4
7X4

135,0
178,0
220,0
270,0
355,0

11,0
11,6
13,0
14,5
16,0

194
250
302
370
498

223 0060 002


223 0060 003
223 0060 004
223 0060 005
223 0060 007

2X6
3X6
4X6
5X6
7X6

175,0
240,0
305,0
440,0
505,0

12,1
13,4
15,0
16,5
18,2

251
285
412
505
671

223 0100 002


223 0100 003
223 0100 004
223 0100 005
223 0100 007

2 X 10
3 X 10
4 X 10
5 X 10
7 X 10

265,0
370,0
485,0
714,0
820,0

15,7
16,7
18,4
20,6
22,8

420
485
620
826
1280

275

CC-data cable LiYCY-JB-225


Coloured cores acc. to CC-colour code, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 225 3x0,34 LiYCY-JB

Technical data
Rated voltage:
300 V
Test voltage:
1200 V
The flexible CC-data cable LiYCY-JB-225 shielded is
suitable as a control and signal cable in data,
measurement and regulating technology. The copper
shield provides reliable transmission of data and
impulses and protects against electrical interferences.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands

Construction

Insulation resistance:
min. 20 MOhm X km

Fine strands of bare copper wire, PVC core


insulation. Core colours acc. to CC-colour code
(pls. refer to technical appendix). 3 cores or more
with green/yellow protective conductor in the outer
layer. Cores twisted in layers. Overall tinned copper
shield. PVC outer sheath, flame retardant
and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001).

fixed installation:
flexible application:

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter

Conductor cross-section (mm2):


Conductor resistance (Ohm/km):
Max. load (Ampere): *
Capacitance at 800 Hz core/core (approx. nF/km):
core/shield (approx. nF/km):
* acc. to DINVDE0298 part 4

276

Temperature range:
-30C to +80C
-5C to +70C

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

0,14
m 138
2
90
190

0,25
m 79
4
100
240

0,34
m 57
6
110
250

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

225 0001 001


225 0001 002
225 0001 003
225 0001 004
225 0001 005
225 0001 006
225 0001 007
225 0001 008
225 0001 009
225 0001 010
225 0001 012
225 0001 014
225 0001 015
225 0001 016
225 0001 018
225 0001 020
225 0001 021
225 0001 024
225 0001 025
225 0001 027
225 0001 030
225 0001 032
225 0001 036
225 0001 040
225 0001 042
225 0001 044
225 0001 048
225 0001 052
225 0001 056
225 0001 061

1 X 0,14
2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
6 X 0,14
7 X 0,14
8 X 0,14
9 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
15 X 0,14
16 X 0,14
18 X 0,14
20 X 0,14
21 X 0,14
24 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
42 X 0,14
44 X 0,14
48 X 0,14
52 X 0,14
56 X 0,14
61 X 0,14

8,0
12,6
14,1
15,9
19,5
22,0
24,0
26,0
28,0
31,2
32,0
35,0
40,0
49,0
54,0
58,0
60,0
74,0
77,0
85,0
98,0
108,0
117,0
126,0
132,0
138,0
145,0
155,0
166,0
176,0

2,6
3,9
4,1
4,3
4,6
5,0
5,0
5,4
5,7
6,0
6,2
6,7
6,7
7,1
7,4
7,7
7,7
8,3
8,8
8,8
9,0
9,3
9,6
10,2
10,2
10,8
11,1
11,3
11,7
12,0

16
21
25
29
35
37
40
44
50
55
60
66
71
74
93
95
98
106
111
122
129
138
148
165
173
181
192
200
212
243

225 0002 001


225 0002 002
225 0002 003
225 0002 004
225 0002 005
225 0002 006
225 0002 007
225 0002 008
225 0002 010
225 0002 012

1 X 0,25
2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
6 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25

8,1
16,0
21,0
24,0
29,0
30,0
37,0
42,0
46,0
50,0

3,1
4,5
4,7
5,0
5,5
5,9
5,9
6,3
7,4
7,6

17
29
35
44
50
58
60
67
81
91

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

225 0002 014


225 0002 016
225 0002 018
225 0002 021
225 0002 024
225 0002 025
225 0002 027
225 0002 030
225 0002 032
225 0002 036
225 0002 040
225 0002 042
225 0002 044
225 0002 048
225 0002 052
225 0002 056
225 0002 061

14 X 0,25
16 X 0,25
18 X 0,25
21 X 0,25
24 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
42 X 0,25
44 X 0,25
48 X 0,25
52 X 0,25
56 X 0,25
61 X 0,25

64,0
71,0
83,0
105,0
115,0
117,0
120,0
132,0
138,0
152,0
164,0
172,0
180,0
209,0
234,0
259,0
287,0

7,9
8,3
8,7
9,1
10,1
10,3
10,3
10,8
11,2
11,6
12,1
12,1
13,0
13,2
13,6
13,9
14,4

116
133
137
171
185
190
200
214
225
250
269
295
300
310
340
360
385

225 0003 002


225 0003 003
225 0003 004
225 0003 005
225 0003 007
225 0003 008
225 0003 010
225 0003 012
225 0003 014
225 0003 016
225 0003 018
225 0003 021
225 0003 024
225 0003 025
225 0003 027
225 0003 032
225 0003 036
225 0003 040
225 0003 042
225 0003 044
225 0003 050
225 0003 052
225 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
8 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
25 X 0,34
27 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
42 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34

21,0
27,0
33,0
36,0
51,0
54,0
74,0
80,0
86,0
94,0
108,0
127,0
140,0
143,0
151,0
171,0
188,0
208,0
215,0
223,0
266,0
273,0
316,0

5,0
5,2
5,6
6,2
6,9
7,4
8,4
8,7
9,2
9,6
10,0
10,6
11,7
12,4
12,4
13,0
13,5
14,2
14,2
15,3
15,7
16,2
17,2

33
41
48
58
70
93
110
120
137
152
188
202
252
254
258
296
322
360
377
386
435
449
514

ConCab kabel connects the world

277

CC-data cable LiYCY-(TP)-240


Coloured cores acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 240 2x2x0,34 LiYCY(TP)

Technical data
Rated voltage:
up to 0,34 mm2:
300 V
from 0,50 mm2: 300/500 V
up to 0,34 mm2:
from 0,50 mm2:

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands

The flexible CC-data cable LiYCY-TP-240 shielded is


suitable as a control and signal cable in data,
measurement, and regulating technology.
Synchronized twisted core pair lengths cause
minimum coupling values. The copper shield provides
reliable transmission of data and impulses and
protects against electrical interferences.

Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire,
PVC core insulation. Core colours acc. to DIN 47100.
Cores twisted in short lenghts, pairs twisted in layers,
tinned copper shield. PVC outer sheath, flame retardant and self extinguishing (acc. to DIN VDE,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Conductor cross-section (mm2):


Loop resistance (Ohm/km):
Max. load (Ampere):*
Capacitance at 800 Hz
core/core (approx. nF/km):
core/shield (approx. nF/km):
Cable attenuation at 800 Hz (dB/km):

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

Approvals:
acc. to DIN VDE 0281, 0812, 0814

0,14

0,25

0,34

0,5

0,75

1,0

1,5

m 276 m 158 m 114 m 78 m 52 m 39 m 26,6


2
4
6
9
12
15
18
90
130

100
140

110
150

120
160

120
160

120
160

120
160

2,3

1,9

1,5

1,3

1,0

0,7

0,5

* acc. to DINVDE0298 part 4

278

Test voltage:
1200 V
2000 V

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

240 0001 002


240 0001 003
240 0001 004
240 0001 005
240 0001 006
240 0001 007
240 0001 008
240 0001 010
240 0001 012
240 0001 014
240 0001 016
240 0001 018
240 0001 020
240 0001 024
240 0001 025

2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
5 X 2 X 0,14
6 X 2 X 0,14
7 X 2 X 0,14
8 X 2 X 0,14
10 X 2 X 0,14
12 X 2 X 0,14
14 X 2 X 0,14
16 X 2 X 0,14
18 X 2 X 0,14
20 X 2 X 0,14
24 X 2 X 0,14
25 X 2 X 0,14

18,5
23,0
26,6
31,0
49,0
51,1
53,7
59,0
66,0
74,0
79,0
83,0
97,0
111,0
113,0

5,3
5,9
6,4
7,2
7,5
7,5
8,1
8,9
9,4
10,1
10,5
11,1
11,4
12,5
12,8

40
50
56
75
85
88
103
125
142
158
164
177
193
238
242

240 0002 002


240 0002 003
240 0002 004
240 0002 005
240 0002 006
240 0002 008
240 0002 010
240 0002 012
240 0002 016
240 0002 024
240 0002 025

2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
12 X 2 X 0,25
16 X 2 X 0,25
24 X 2 X 0,25
25 X 2 X 0,25

28,0
32,0
38,0
52,0
65,0
75,0
110,0
117,0
143,0
223,0
233,0

6,1
6,5
7,3
8,0
8,3
9,3
10,3
10,8
12,3
14,4
15,0

46
57
73
88
100
118
165
190
220
333
336

240 0003 002


240 0003 003
240 0003 004
240 0003 005
240 0003 006
240 0003 007
240 0003 008
240 0003 010
240 0003 012
240 0003 016
240 0003 018
240 0003 025

2 X 2 X 0,34
3 X 2 X 0,34
4 X 2 X 0,34
5 X 2 X 0,34
6 X 2 X 0,34
7 X 2 X 0,34
8 X 2 X 0,34
10 X 2 X 0,34
12 X 2 X 0,34
16 X 2 X 0,34
18 X 2 X 0,34
25 X 2 X 0,34

36,0
44,9
54,2
63,5
74,0
81,0
90,0
108,0
121,0
159,0
198,0
240,0

7,1
7,7
8,4
9,4
9,9
9,9
10,8
12,0
13,2
14,6
15,6
18,2

64
86
113
115
137
145
161
230
236
270
300
414

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
5 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
25 X 2 X 0,5

50,0
70,0
85,0
105,0
120,0
140,0
178,0
199,0
254,0
302,0
346,0

7,7
8,3
9,4
9,8
11,1
12,1
13,6
14,5
16,6
18,2
20,1

98
130
155
165
208
264
315
353
470
525
622

240 0007 002 2 X 2 X 0,75


240 0007 003 3 X 2 X 0,75
240 0007 004 4 X 2 X 0,75
240 0007 005 5 X 2 X 0,75
240 0007 006 6 X 2 X 0,75
240 0007 008 8 X 2 X 0,75
240 0007 016 16 X 2 X 0,75
240 0007 020 20 X 2 X 0,75
240 0007 025 25 X 2 X 0,75

58,0
84,0
108,0
126,0
146,0
180,0
328,0
392,0
470,0

8,4
9,4
10,3
11,5
12,1
13,3
18,7
21,1
22,5

106
140
179
215
246
305
564
671
805

240 0010 002


240 0010 003
240 0010 004
240 0010 005

2 X 2 X 1,0
3 X 2 X 1,0
4 X 2 X 1,0
5 X 2 X 1,0

82,0
103,0
121,0
161,0

9,1
10,0
11,1
12,2

136
174
226
266

240 0015 002


240 0015 003
240 0015 004

2 X 2 X 1,5
3 X 2 X 1,5
4 X 2 X 1,5

111,0
136,0
172,0

10,2
12,2
13,5

168
228
286

kg/km
240 0005 002
240 0005 003
240 0005 004
240 0005 005
240 0005 006
240 0005 008
240 0005 010
240 0005 012
240 0005 016
240 0005 020
240 0005 025

ConCab kabel connects the world

Weight
kg / km

279

CC-data cable blue LiYCY-(TP)-128


Twisted pair data cable with blue outer sheath, shielded
For intrinsically safe electric circuits
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 128 20x2x0,5 LiYCY(TP)

The shielded CC-data cable blue LiYCY-(TP)-128 corresponds to the stipulations of DIN VDE 0165 section
12.2.2 and is suitable as a data cable for interference-free transmission of analogue and digital signals for
intrinsically safe electric circuits. The overall shield ensures a reliable transmission of data and impulses and
protects against electrical interferences. For stipulations appertaining to specific applications refer to DIN
VDE 0165.

Technical data
Construction
Fine strands of bare copper wire. PVC core
insulation. Core colours acc. to DIN 47100. Cores
twisted in short lengths, pairs twisted in layers, foil
wrapping, tinned copper drain wire, tinned copper
shield. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour blue (RAL 5015).
Part-No.

128 0005 002


128 0005 003
128 0005 004
128 0005 006
128 0005 008
128 0005 012
128 0005 016
128 0005 020
128 0005 025
128 0007 002
128 0007 003
128 0007 004
128 0007 006
128 0007 008
128 0007 012
128 0007 016
128 0007 020
128 0007 025

280

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

2 X 2 X 0,50
3 X 2 X 0,50
4 X 2 X 0,50
6 X 2 X 0,50
8 X 2 X 0,50
12 X 2 X 0,50
16 X 2 X 0,50
20 X 2 X 0,50
25 X 2 X 0,50

54,0
70,0
91,0
120,0
144,0
237,0
254,0
304,0
360,0

7,7
9,1
10,3
12,3
13,3
15,3
17,9
19,2
20,9

2 X 2 X 0,75
3 X 2 X 0,75
4 X 2 X 0,75
6 X 2 X 0,75
8 X 2 X 0,75
12 X 2 X 0,75
16 X 2 X 0,75
20 X 2 X 0,75
25 X 2 X 0,75

60,0
92,0
115,0
146,0
180,0
270,0
330,0
434,0
530,0

8,8
9,7
11,0
13,3
14,9
17,9
20,1
21,6
24,4

Rated voltage:
300/500 V
Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Weight

Loop resistance:
0,50 mm2: max. 78 Ohm/km
0,75 mm2: max. 52 Ohm/km

kg/km
98
130
155
208
264
353
470
525
622
106
140
179
246
305
456
564
671
805

Capacitance at 800 Hz:


core/core: approx. 120 -150 nF/km
core/shield: approx. 180 -240 nF/km
Inductance:
approx. 0,7 mH/km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

CC-data cable LiYCY-CY-224


Core and overall shield, core colours acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 224 3x0,25 LiYCY-CY

The flexible CC-data cable LiYCY-CY-224 with shielded cores and an overall copper shield is suitable for
extensive interference-free transmissions when electromagnetic compatibility (EMC) is required. In order to
avoid reciprocal influences within the data cable, every core is separately shielded.

Construction
Technical data

Fine strands of bare copper wire. PVC core insulation.


Core colours acc. to DIN 47100. Every core is copper
shielded and PVC sheathed. Cores twisted in layers,
foil wrapping, tinned copper shield. PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
Part-No.

No. of
cores
+
crosssection

Rated voltage:
300V
Test voltage:
1200 V

Outer
diameter
approx.

Weight

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5

kg/km

mm

kg/km

Insulation resistance:
min. 20 MOhm X km

Copper
weight

224 0001 002


224 0001 003
224 0001 004
224 0001 005
224 0001 007

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14

36,5
42,1
51,3
61,4
78,0

6,1
6,4
7,1
7,7
8,3

63
72
86
103
131

224 0002 002


224 0002 003
224 0002 004
224 0002 005
224 0002 007

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25

41,5
53,0
65,0
78,0
94,0

6,4
7,2
7,8
8,5
9,2

69
106
130
161
196

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 15 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

281

CC-data cable LiYCY-CY-(TP)-241


Paired and overall shield, core colours acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 241 3x2x0,25 LiYCY-CY(TP)

Technical data
Rated voltage:
300 V
Test voltage:
1200 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Impedance:
approx. 80 Ohm
The flexible CC-data cable LiYCY-CY-(TP)-241 with
individually shielded pairs and overall shield is used
as a link-up cable in electronics, measurement, control
and regulating technology. The shielded pairs ensure
interference-free transmission. Each shielded pair with
PVC contact protection to avoid voltage interference.
Synchronized twisted core pair lengths cause
minimum coupling values.

Inductance:
approx. 0,67 mH/km
core/core:
core/shield:

Capacitance at 800 Hz:


approx. 120 -150 nF/km
approx. 180 -240 nF/km
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of bare copper wire. PVC core
insulation. Core colours acc. to DIN 47100.
Cores twisted in pairs tinned copper shield, pairs with
PVC sheath, sheathed pairs in layers, foil wrapping,
tinned copper drain wire, overall tinned copper shield.
PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

282

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
15 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

241 0001 002


241 0001 003
241 0001 004
241 0001 005
241 0001 006
241 0001 007
241 0001 008
241 0001 009
241 0001 010
241 0001 012
241 0001 016
241 0001 020

2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
5 X 2 X 0,14
6 X 2 X 0,14
7 X 2 X 0,14
8 X 2 X 0,14
9 X 2 X 0,14
10 X 2 X 0,14
12 X 2 X 0,14
16 X 2 X 0,14
20 X 2 X 0,14

35,0
45,0
54,0
62,0
71,0
82,0
97,0
110,0
112,0
140,0
179,0
230,0

7,5
7,8
9,5
10,5
11,0
11,0
13,0
14,0
14,0
15,1
17,2
17,8

95
101
134
157
185
227
245
278
325
380
440
520

241 0002 002


241 0002 003
241 0002 004
241 0002 005
241 0002 006
241 0002 007
241 0002 008
241 0002 010
241 0002 012
241 0002 016
241 0002 020
241 0002 024

2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
7 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
12 X 2 X 0,25
16 X 2 X 0,25
20 X 2 X 0,25
24 X 2 X 0,25

55,0
68,0
80,9
98,1
129,6
142,5
162,9
210,5
236,6
300,0
335,0
456,0

9,7
10,0
12,1
12,3
13,2
13,2
15,5
16,6
17,0
21,0
22,6
27,5

125
140
205
230
275
295
330
420
465
578
618
678

241 0003 004

4 X 2 X 0,34

130,0

12,6

280

241 0005 002


241 0005 003
241 0005 004

2 X 2 X 0,50
3 X 2 X 0,50
4 X 2 X 0,50

91,0
110,0
153,0

10,8
12,5
13,5

193
210
302

ConCab kabel connects the world

283

CC-data cable LIY-LIYCY-Y-222


With respectively 1 or 2 shielded cores
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 222 2x0,5+1x0,25 LiY-LiYCY-Y

The flexible CC-data cable LiY-LiYCY-Y-222 with respectively 1 or 2 individually shielded cores is used as
a link-up cable in electronics, measurement, control and regulating technology. The shielded cores ensure an
interference-free transmission. The shielded cores are PVC sheathed.

Construction

Technical data

Fine strands of bare copper wire. PVC core


insulation, core colours acc. to DIN 47100,
1 or 2 cores individually copper shielded and PVC
sheathed. All cores twisted in layers.
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7032).

Rated voltage:
300 V

Part-No.

Weight

kg/ km

Outer
diameter
approx.
mm

222 0225 125 2 X 0,25+1 X (0,25)


222 0325 125 3 X 0,25+1 X (0,25)
222 0425 125 4 X 0,25+1 X (0,25)
222 0625 125 6 X 0,25+1 X (0,25)
222 0725 125 7 X 0,25+1 X (0,25)
222 1025 125 10 X 0,25+1 X (0,25)

11,5
13,9
16,3
21,1
23,5
30,7

4,8
5,1
5,4
6,1
6,1
7,5

35
41
45
54
62
76

222 2052 05
222 4052 05
222 6052 05
222 8052 05
222 1005 205
222 1405 205

34,4
44,0
53,6
63,2
72,8
92,0

8,4
8,9
10,0
10,1
11,3
11,5

91
120
145
156
187
231

284

No. of cores
+
crosssection

2 X 0,5+2 X (0,5)
4 X 0,5+2 X (0,5)
6 X 0,5+2 X (0,5)
8 X 0,5+2 X (0,5)
10 X 0,5+2 X (0,5)
14 X 0,5+2 X (0,5)

Copper
weight

kg /km

Test voltage (core/core):


1200 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Capacitance at 800 Hz:
core/core:
approx. 80 nF/km
core/shield:
approx. 180 nF/km
Insulation resistance:
min. 20 MOhm x km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 x cable diameter
15 x cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281, 0812

CC-data cable LiFYDY-243


High flexible miniature electronic cable, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 243 12x0,08 LIFYDY

The CC-data cable LiFYDY-243 shielded is suitable


as a highly flexible link-up cable for electronic
appliances. The copper shield ensures reliable
transmission of data and impulses and protects against
electrical interferences.

Technical data

Construction
Fine strands of bare copper wire. PVC core insulation.
Core colours acc. to DIN 47100, cores twisted in
layers, foil wrapping, tinned copper shield. PVC outer
sheath, flame retardant and self-extinguishing (acc. to
DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7032).
Part-No.

No. of cores
+
crosssection

Copper
weight

243 0500 503


243 0500 504
243 0500 505
243 0500 507
243 0500 512
243 0500 518
243 0500 524

3 X 0,05
4 X 0,05
5 X 0,05
7 X 0,05
12 X 0,05
18 X 0,05
24 X 0,05

6,0
7,0
8,3
9,0
14,5
20,0
24,4

3,1
3,3
3,6
3,8
5,1
5,5
6,6

14,8
16,0
18,8
21,9
36,4
52,0
62,5

243 0500 802


243 0500 803
243 0500 804
243 0500 807
243 0500 812
243 0500 818

2 X 0,08
3 X 0,08
4 X 0,08
7 X 0,08
12 X 0,08
18 X 0,08

7,6
8,4
10,1
14,0
23,0
32,0

3,8
4,0
4,2
4,7
6,3
6,4

20,0
21,8
24,2
31,8
53,4
75,6

kg/km

Outer
diameter
approx.
mm

Rated voltage:
100 V
Test voltage:
800 V
Conductor stranding:
superfine copper strands,
single wire diameter 0,05 mm

Weight
kg/km

core/core:
core/shield:

Capacitance at 800 Hz:


approx. 100 nF/km
approx. 120 nF/km
Insulation resistance:
min. 20 MOhm x km

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 x cable diameter
7,5 x cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0812

285

CC-data cable LiFYCY-(TP)-244


High flexible miniature electronic cable, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 244 6x2x0,20 LiFYCY(TP)

The paired CC-data cable LiFYCY-(TP)-244 is suitable as a highly flexible link-up cable for electronic
appliances. Synchronized twisted core pair lengths cause minimum coupling values. The copper shield
ensures a reliable transmission of data and impulses and protects against electrical interferences.

Construction

Technical data

Fine strands of bare copper wire. PVC core


insulation, core colours acc. to DIN 47100, core
pairs twisted in layers, foil wrapping, tinned copper
drain wire, overall tinned copper shield. PVC outer
sheath, flame retardant and self-extinguising
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
Part-No.

No. of cores
+
crosssection

244 05 008 03 3 X 2 X 0,08


244 05 008 04 4 X 2 X 0,08
244 05 008 06 6 X 2 X 0,08
244 05 008 08 8 X 2 X 0,08
244 05 008 12 12 X 2 X 0,08
244 05 008 18 18 X 2 X 0,08
244 05 020 02
244 05 020 03
244 05 020 04
244 05 020 05
244 05 020 06
244 05 020 07
244 05 020 08
244 05 020 10
244 05 020 12
244 05 020 16
244 05 020 18
244 05 020 20
244 05 020 24
244 05 020 32

286

2 X 2 X 0,20
3 X 2 X 0,20
4 X 2 X 0,20
5 X 2 X 0,20
6 X 2 X 0,20
7 X 2 X 0,20
8 X 2 X 0,20
10 X 2 X 0,20
12 X 2 X 0,20
16 X 2 X 0,20
18 X 2 X 0,20
20 X 2 X 0,20
24 X 2 X 0,20
32 X 2 X 0,20

Copper
weight
kg/ km

Outer
diameter
approx.
mm

Weight
kg /km

Rated voltage:
0,08 mm2:
100 V
0,20 mm2:
250 V
0,08 mm2:
0,20 mm2:

Test voltage:
800 V
1200 V

Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6
single wire diameter 0,05 mm

14,6
17,3
22,4
38,1
48,1
64,8

4,9
5,1
6,2
6,7
8,3
9,3

32,0
37,0
48,0
76,0
96,0
138,0

Capacitance at 800 Hz:


core/core: approx. 80-120 nF/km
core/shield: approx. 120-160 nF/km

24,0
35,0
45,0
54,0
56,0
68,0
72,0
108,0
125,0
144,0
155,0
216,0
228,0
269,0

6,0
6,6
7,1
7,9
8,5
8,9
9,3
9,9
10,3
12,5
13,0
13,9
14,8
16,6

60,0
70,0
80,0
90,0
100,0
120,0
130,0
150,0
180,0
210,0
230,0
250,0
330,0
400,0

Insulation resistance:
min. 20 MOhm x km

Capacitance coupling at 1 kHz:


200 pF/100m to 300 pF/100m

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:
flexible application:

Bending radius:
5 x cable diameter
7,5 x cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0812

287

CC-data cable LiHH-217


Halogen-free, core colour acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 217 24x0,75 LiHH

Technical data
Rated voltage:
m 0,34 mm2:
300 V
L 0,34 mm2:
300/500 V
m 0,34 mm2:
L 0,34 mm2:

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands

The flexible CC-data cable LiHH-217 is suitable as a


control and signal cable in data, measurement and
regulating technology. The halogen-free and flame
retardant insulation and sheath mixture greatly
improve the safety of humans and materials in
the event of fire.

Construction
Fine strands of bare copper wire, halogen-free
polymer mixture core insulation, core colours acc.
to DIN 47100, cores twisted in layers. Outer sheath
halogen-free polymer mixture, flame retardant (acc.
to DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1). Colour grey (RAL 7032).
Conductor cross-section (mm2):
Conductor resistance (Ohm/km):
Max. load (Ampere): *

0,14 0,25
m 138 m 79
2
4

Insulation resistance:
min. 20 MOhm x km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

fixed installation:

Bending radius:
7,5 x cable diameter

Approvals:
acc. to DIN VDE 0281, 0812
0,34
m 57
6

0,5
m 39
9

* acc. to DINVDE0298 part 4

288

Test voltage:
1200 V
2000 V

ConCab kabel connects the world

0,75
m 26
12

1,0
1,5
m19,5 m13,3
15
18

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

217 0001 002


217 0001 003
217 0001 004
217 0001 005
217 0001 007
217 0001 008
217 0001 012
217 0001 014
217 0001 016
217 0001 018
217 0001 021
217 0001 024
217 0001 027
217 0001 030
217 0001 032
217 0001 036
217 0001 040
217 0001 044
217 0001 050
217 0001 052
217 0001 061

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
8 X 0,14
12 X 0,14
14 X 0,14
16 X 0,14
18 X 0,14
21 X 0,14
24 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
44 X 0,14
50 X 0,14
52 X 0,14
61 X 0,14

2,7
4,0
5,4
6,7
9,4
10,8
16,1
18,8
21,5
24,2
28,2
32,3
36,3
40,3
43,0
48,4
53,8
59,1
67,2
69,9
82,0

3,1
3,3
3,5
3,8
4,1
4,7
5,3
5,5
6,0
6,3
6,9
7,3
7,7
7,9
8,2
8,5
9,1
9,5
10,3
10,3
10,9

14
16
19
23
28
34
45
51
60
66
74
82
90
98
108
115
133
155
162
165
189

217 0002 002


217 0002 003
217 0002 004
217 0002 005
217 0002 007
217 0002 008
217 0002 012
217 0002 014
217 0002 016
217 0002 018
217 0002 021
217 0002 024
217 0002 027
217 0002 030
217 0002 032
217 0002 036
217 0002 040
217 0002 044
217 0002 050
217 0002 052
217 0002 061

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
8 X 0,25
12 X 0,25
14 X 0,25
16 X 0,25
18 X 0,25
21 X 0,25
24 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
44 X 0,25
50 X 0,25
52 X 0,25
61 X 0,25

4,8
7,2
9,6
12,0
16,8
19,2
28,8
33,6
38,4
43,2
50,4
57,6
64,8
72,0
76,8
86,4
96,0
105,6
120,0
124,8
146,4

3,4
3,6
3,9
4,2
4,6
5,2
6,1
6,4
6,7
7,1
7,9
8,4
8,6
8,9
9,2
10,0
10,6
11,1
11,6
11,6
12,3

21
24
29
38
46
54
74
83
94
104
116
140
153
166
183
196
212
244
260
265
318

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

217 0003 002


217 0003 003
217 0003 004
217 0003 005
217 0003 007
217 0003 008
217 0003 012
217 0003 014
217 0003 016
217 0003 018
217 0003 021
217 0003 024
217 0003 027
217 0003 030
217 0003 032
217 0003 036
217 0003 040
217 0003 044
217 0003 050
217 0003 052
217 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
8 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
27 X 0,34
30 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34

6,5
9,8
13,1
16,3
22,8
26,1
39,2
45,7
52,2
58,8
68,5
78,3
88,1
97,9
104,4
117,5
130,6
143,6
163,2
169,7
199,1

4,0
4,2
4,6
5,0
5,5
6,5
7,3
7,9
8,3
8,8
10,0
10,6
10,8
11,2
11,6
12,1
12,9
13,5
14,5
14,5
15,4

26
31
39
48
61
69
96
107
121
135
161
180
198
215
238
255
276
330
356
362
415

217 0005 002


217 0005 003
217 0005 004
217 0005 005
217 0005 007
217 0005 008
217 0005 012
217 0005 014
217 0005 016
217 0005 018
217 0005 021
217 0005 024
217 0005 027
217 0005 030
217 0005 032
217 0005 036
217 0005 044
217 0005 050
217 0005 061

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
7 X 0,5
8 X 0,5
12 X 0,5
14 X 0,5
16 X 0,5
18 X 0,5
21 X 0,5
24 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
36 X 0,5
44 X 0,5
50 X 0,5
61 X 0,5

9,6
14,4
19,2
24,0
33,6
38,4
57,6
67,2
76,8
86,4
100,8
115,2
129,6
144,0
153,6
172,8
211,2
240,0
292,8

4,3
4,5
4,9
5,4
6,1
7,1
8,1
8,5
9,0
9,5
10,9
11,5
11,7
12,1
12,6
13,1
15,1
15,7
16,7

36
42
55
65
80
103
128
150
169
189
217
255
278
306
329
379
441
492
564

ConCab kabel connects the world

289

CC-data cable LiHH-217


Halogen-free, core colour acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

Part-No.

290

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

217 0007 002


217 0007 003
217 0007 004
217 0007 005
217 0007 007
217 0007 008
217 0007 012
217 0007 014
217 0007 016
217 0007 018
217 0007 021
217 0007 024
217 0007 027
217 0007 030
217 0007 032
217 0007 036

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75
18 X 0,75
21 X 0,75
24 X 0,75
27 X 0,75
30 X 0,75
32 X 0,75
36 X 0,75

14,4
21,6
29,0
36,0
50,0
58,0
86,0
101,0
115,0
130,0
151,0
173,0
195,0
216,0
230,0
259,0

5,4
5,7
6,2
6,8
7,4
8,7
9,9
10,3
10,8
11,4
12,5
13,3
13,6
14,5
15,0
15,6

47
56
69
83
98
132
172
213
239
266
297
335
366
420
451
495

217 0010 002


217 0010 003
217 0010 004
217 0010 005
217 0010 006
217 0010 007

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0

19,2
29,0
38,4
48,0
58,0
67,0

5,8
6,1
6,6
7,5
8,1
8,1

50
57
67
82
118
124

217 0015 002


217 0015 003
217 0015 004
217 0015 005
217 0015 006
217 0015 007

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

29,0
43,0
58,0
72,0
86,0
101,0

7,0
7,4
8,0
8,8
9,6
9,6

59
72
87
142
168
178

ConCab kabel connects the world

CC-data cable LiHCH-227


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 227 12x0,25 LiHCH

Technical data
Rated voltage:
m 0,34 mm2:
300 V
L 0,34 mm2:
300/500 V
The flexible CC-data cable LiHCH-227
shielded is suitable as a control and signal cable in
data, measurement and regulating
technology. The halogen-free and flame
retardant insulation and sheath mixture ensure a
greatly improved protection for humans and materials
in the event of fire. The overall tinned copper shield
ensures reliable transmission of data and impulses and
protects against electrical interferences.

m 0,34 mm2:
L 0,34 mm2:

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 20 MOhm x km

Construction
Fine strands of bare copper wire, halogen-free
polymer mixture insulation, core colours acc. to
DIN 47100, cores twisted in layers, foil wrapping,
overall tinned copper shield. Outer sheath halogenfree polymer mixture, flame retardant
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL7032).
Cross-section (mm2):
Conductor resistance (Ohm/km):
Max. load (Ampere): *
* acc. to DINVDE0298 part 4

0,14
m 138
2

Test voltage:
1200 V
2000 V

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 7,5 x cable diameter
Approvals:
acc. to DIN VDE 0281, 0812
0,25
m 79
4

0,34
m 57
6

ConCab kabel connects the world

0,5
m 39
9

0,75
1,0
1,5
m 26 m 19,5 m 13,3
12
15
18

291

CC-data cable LiHCH-227


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

Part-No.

292

Copper
weight

kg/km

No. of
cores
+
crosssection

Outer
diameter
approx.

Weight

227 0001 002


227 0001 003
227 0001 004
227 0001 005
227 0001 007
227 0001 008
227 0001 010
227 0001 012
227 0001 014
227 0001 016
227 0001 018
227 0001 021
227 0001 024
227 0001 025
227 0001 027
227 0001 030
227 0001 032
227 0001 036
227 0001 040
227 0001 044
227 0001 050
227 0001 052
227 0001 061

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
7 X 0,14
8 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
16 X 0,14
18 X 0,14
21 X 0,14
24 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
44 X 0,14
50 X 0,14
52 X 0,14
61 X 0,14

12,6
14,1
15,9
19,5
24,0
26,0
31,2
32,0
35,0
49,0
54,0
60,0
74,0
77,0
85,0
98,0
108,0
117,0
126,0
138,0
150,0
155,0
176,0

3,9
4,1
4,3
4,6
5,0
5,4
6,0
6,2
6,7
7,1
7,4
7,7
8,3
8,8
8,8
9,0
9,3
9,6
10,2
10,8
11,1
11,3
12,0

21
25
29
35
40
44
55
60
66
74
93
105
106
111
122
129
138
148
165
182
196
200
243

227 0002 002


227 0002 003
227 0002 004
227 0002 005
227 0002 007
227 0002 008
227 0002 010
227 0002 012
227 0002 014
227 0002 016
227 0002 018

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
16 X 0,25
18 X 0,25

16,0
21,0
24,0
29,0
37,0
42,0
46,0
50,0
64,0
71,0
83,0

4,5
4,7
5,0
5,5
5,9
6,3
7,4
7,6
8,1
8,3
8,7

29
35
44
50
60
67
81
91
116
133
137

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outerdiameter
approx.

Weight

kg/km

ca. mm

kg / km

227 0002 021


227 0002 024
227 0002 025
227 0002 027
227 0002 030
227 0002 032
227 0002 036
227 0002 040
227 0002 044
227 0002 050
227 0002 052
227 0002 061

21 X 0,25
24 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
44 X 0,25
50 X 0,25
52 X 0,25
61 X 0,25

105,0
115,0
117,0
120,0
132,0
138,0
152,0
164,0
180,0
222,0
234,0
287,0

9,1
10,1
10,3
10,3
10,8
11,2
11,6
12,1
13,1
13,6
13,6
14,8

171
185
190
200
214
227
250
269
300
325
340
385

227 0003 002


227 0003 003
227 0003 004
227 0003 005
227 0003 007
227 0003 008
227 0003 010
227 0003 012
227 0003 014
227 0003 016
227 0003 018
227 0003 021
227 0003 024
227 0003 025
227 0003 027
227 0003 030
227 0003 032
227 0003 036
227 0003 040
227 0003 044
227 0003 050
227 0003 052
227 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
7 X 0,34
8 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
25 X 0,34
27 X 0,34
30 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34

21,0
27,0
33,0
36,0
51,0
54,0
74,0
80,0
86,0
94,0
108,0
127,0
140,0
143,0
151,0
162,0
171,0
188,0
208,0
223,0
266,0
273,0
316,0

5,0
5,2
5,6
6,2
6,9
7,4
8,4
8,7
9,2
9,6
10,0
10,6
11,7
12,4
12,4
12,5
13,0
13,5
14,2
15,3
15,7
16,2
17,2

33
41
48
58
70
93
110
120
137
152
188
202
252
254
258
265
296
322
360
386
435
449
514

kg/km

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

ca. mm

kg/km

227 0005 002


227 0005 003
227 0005 004
227 0005 005
227 0005 007
227 0005 008
227 0005 010
227 0005 012
227 0005 014
227 0005 016
227 0005 018
227 0005 021
227 0005 027
227 0005 030
227 0005 032
227 0005 036
227 0005 044
227 0005 050
227 0005 061

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
7 X 0,5
8 X 0,5
10 X 0,5
12 X 0,5
14 X 0,5
16 X 0,5
18 X 0,5
21 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
36 X 0,5
44 X 0,5
50 X 0,5
61 X 0,5

29,0
38,0
45,0
57,0
80,0
85,0
100,0
112,0
122,0
140,0
152,0
168,0
221,0
230,0
258,0
280,0
310,0
340,0
415,0

5,7
5,9
6,4
7,0
7,7
8,3
9,6
9,9
10,4
11,5
11,9
12,5
13,9
14,5
15,3
15,1
17,3
19,0
20,8

42
51
61
76
98
111
141
156
186
195
215
268
331
348
373
390
422
552
659

227 0007 002


227 0007 003
227 0007 004
227 0007 005
227 0007 007
227 0007 008
227 0007 012
227 0007 014
227 0007 016
227 0007 018
227 0007 021
227 0007 027
227 0007 030
227 0007 032
227 0007 036
227 0010 002
227 0010 003
227 0010 004
227 0010 005
227 0010 006
227 0010 007
227 0015 002
227 0015 003
227 0015 004
227 0015 005
227 0015 006
227 0015 007

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75
18 X 0,75
21 X 0,75
27 X 0,75
30 X 0,75
32 X 0,75
36 X 0,75
2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0
2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

38,0
49,0
58,0
70,0
100,0
110,0
154,0
167,0
183,0
205,0
236,0
275,0
315,0
330,0
370,0
55,0
70,0
80,0
95,0
105,0
120,0
65,0
90,0
110,0
125,0
144,0
159,0

6,1
6,4
7,0
7,7
8,3
9,1
10,9
11,7
12,3
12,7
13,6
15,7
16,1
16,7
17,7
6,6
6,9
7,6
8,2
9,2
9,2
7,8
8,1
8,9
9,7
10,7
10,7

56
75
95
130
168
173
232
260
296
315
369
485
500
520
606
84
110
130
156
178
192
97
125
165
193
219
245

ConCab kabel connects the world

293

CC-data cable LiHCH-(TP)-228


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 228 2x2x0,34 LiHCH(TP)

Technical data
Rated voltage:
m 0,34 mm2:
300 V
L 0,34 mm2:
300/500 V
The flexible CC-data cable LiHCH-(TP)-228 shielded
is suitable as a control and signal cable in data,
measurement and regulating technology. The halogenfree and flame retardant insulation ensure a greatly
improved protection for humans and materials in the
event of fire. Synchronized twisted core pair lengths
cause minimum coupling values. The overall tinned
copper shield ensures reliable transmission of data and
impulses and protects against electrical interferences.

m 0,34 mm2:
L 0,34 mm2:

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34mm2: 7-strands
Insulation resistance:
min. 20 MOhm x km

Construction
Fine strands of bare copper wire, halogen-free
polymer mixture insulation, core colours acc.
to DIN 47100, cores twisted in pairs, pairs twisted in
layers, foil wrapping, overall tinned copper shield.
Outer sheath halogen-free polymer mixture, flame
retardant (acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
Conductor cross-section (mm2):
Loop resistance (Ohm/km):
Max. load (Ampere): *
* acc. to DINVDE 0298 part 4

294

Test voltage:
1200 V
2000 V

fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 7,5 x cable diameter
Approvals:
acc. to DIN VDE 0281, 0812
0,14
m 276
2

0,25
m 158
4

ConCab kabel connects the world

0,34
m 114
6

0,5
m 78
9

0,75
m 52
12

Part-No.

No. of
cores
+
crosssection

Copper
Outer
weight diameter
approx.

Weight

kg/km

mm

kg/km

228 0001 002


228 0001 003
228 0001 004
228 0001 005
228 0001 006
228 0001 008
228 0001 010
228 0001 012
228 0001 014
228 0001 016
228 0001 018
228 0001 025

2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
5 X 2 X 0,14
6 X 2 X 0,14
8 X 2 X 0,14
10 X 2 X 0,14
12 X 2 X 0,14
14 X 2 X 0,14
16 X 2 X 0,14
18 X 2 X 0,14
25 X 2 X 0,14

24,8
28,1
32,4
37,4
48,5
53,7
61,2
68,4
76,0
84,3
92,8
128,0

5,6
5,7
6,5
7,0
7,2
7,8
8,9
9,7
10,0
10,5
11,1
12,8

36
42
51
61
68
79
100
110
121
133
154
198

228 0002 002


228 0002 003
228 0002 004
228 0002 005
228 0002 006
228 0002 008
228 0002 010
228 0002 012
228 0002 016
228 0002 018
228 0002 025

2 X 2 X 0,25
3 X 2 X 0,25
4 X 2 X 0,25
5 X 2 X 0,25
6 X 2 X 0,25
8 X 2 X 0,25
10 X 2 X 0,25
12 X 2 X 0,25
16 X 2 X 0,25
18 X 2 X 0,25
25 X 2 X 0,25

34,1
39,8
46,9
55,0
69,5
77,0
110,0
120,0
146,0
175,0
227,0

6,9
7,0
7,4
8,0
8,6
9,4
11,0
11,4
12,6
13,2
16,5

43
56
71
77
88
106
131
158
190
218
264

228 0003 002 2 X 2 X 0,34


228 0003 003 3 X 2 X 0,34
228 0003 004 4 X 2 X 0,34
228 0003 005 5 X 2 X 0,34
228 0003 006 6 X 2 X 0,34
228 0003 008 8 X 2 X 0,34
228 0003 012 12 X 2 X 0,34
228 0003 018 18 X 2 X 0,34

41,1
48,8
61,0
69,0
78,9
97,5
148,0
197,8

7,6
7,7
8,8
9,5
10,0
10,9
13,4
15,3

60
73
99
115
124
140
221
294

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

228 0005 002 2 X 2 X 0,5


228 0005 003 3 X 2 X 0,5
228 0005 004 4 X 2 X 0,5
228 0005 005 5 X 2 X 0,5
228 0005 006 6 X 2 X 0,5
228 0005 008 8 X 2 X 0,5
228 0005 010 10 X 2 X 0,5
228 0005 012 12 X 2 X 0,5
228 0005 018 18 X 2 X 0,5

54,0
74,0
82,0
94,0
120,0
144,0
178,0
199,0
284,0

8,5
8,6
9,4
10,2
11,2
12,4
13,2
14,9
16,9

66
83
112
129
144
182
225
263
388

228 0007 002 2 X 2 X 0,75


228 0007 003 3 X 2 X 0,75
228 0007 004 4 X 2 X 0,75
228 0007 005 5 X 2 X 0,75
228 0007 006 6 X 2 X 0,75
228 0007 008 8 X 2 X 0,75
228 0007 012 12 X 2 X 0,75
228 0007 018 18 X 2 X 0,75

68,0
84,0
108,0
128,0
146,0
189,0
290,0
393,0

9,2
9,4
10,9
11,7
12,5
13,7
17,1
19,3

99
112
150
180
216
252
379
519

ConCab kabel connects the world

295

CC-data cable Li2YH-216


Halogen-free, core colour acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 216 25x0,75 Li2YH

Technical data
Rated voltage:
250 V
m 0,14 mm2:
300 V
L 0,14 mm2:
m 0,14 mm2:
L 0,14 mm2:

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands

The flexible CC-data cable Li2YH-216 is


suitable as a control and signal cable in data,
measurement and regulating technology.
The halogen-free and flame retardant sheath ensures
greatly improved protection for humans and materials
in the event of fire.

Insulation resistance:
min. 5 Ohm X km

Construction

fixed installation:
flexible application:

Fine strands of bare copper wire.


PE core insulation, core colours acc. to
DIN 47100, cores twisted in layers. Outer sheath
halogen-free polymer mixture, flame retardant (acc. to
DIN VDE 0482, part 265-2-1 resp. EN 50265-2-1 and
IEC 60332-1). Colour grey (RAL 7032).
Conductor cross-section (mm2):
Conductor resistance (Ohm/km):
Max. load (Ampere):*

0,14
m 138
2

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 7,5 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812
0,25
m 79
4

0,34
m 57
6

0,5
m 39
9

* acc. to DIN VDE0298 part 4

296

Test voltage:
800 V
1200 V

ConCab kabel connects the world

0,75
1,0
1,5
m 26 m 19,5 m 13,3
12
15
18

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

216 0001 002


216 0001 003
216 0001 004
216 0001 005
216 0001 006
216 0001 007
216 0001 008
216 0001 009
216 0001 010
216 0001 012
216 0001 014
216 0001 016
216 0001 018
216 0001 021
216 0001 025
216 0001 027
216 0001 030
216 0001 032
216 0001 036
216 0001 040
216 0001 044
216 0001 050
216 0001 052
216 0001 061

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
6 X 0,14
7 X 0,14
8 X 0,14
9 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
16 X 0,14
18 X 0,14
21 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
44 X 0,14
50 X 0,14
52 X 0,14
61 X 0,14

2,7
4,0
5,4
6,7
8,1
9,4
10,8
12,1
13,4
16,1
18,8
21,5
24,2
28,2
33,7
36,3
40,3
43,0
48,4
53,8
59,1
67,2
69,9
82,0

3,2
3,4
5,4
3,9
4,2
4,2
4,5
5,2
5,4
5,6
5,8
6,1
6,3
6,9
7,3
7,7
7,9
8,2
8,5
9,1
9,5
10,3
10,3
10,9

13
15
18
21
25
27
29
32
35
38
41
52
56
65
70
80
86
92
101
112
119
142
146
165

216 0002 002


216 0002 003
216 0002 004
216 0002 005
216 0002 006
216 0002 007
216 0002 008
216 0002 010
216 0002 012
216 0002 014
216 0002 016
216 0002 018
216 0002 021
216 0002 025
216 0002 027
216 0002 030
216 0002 032
216 0002 036
216 0002 040
216 0002 044
216 0002 050
216 0002 052
216 0002 061

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
6 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
16 X 0,25
18 X 0,25
21 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
44 X 0,25
50 X 0,25
52 X 0,25
61 X 0,25

4,8
7,2
9,6
12,0
14,4
16,8
19,2
24,0
28,8
33,6
38,4
43,2
50,4
60,0
64,8
72,0
76,8
86,4
96,0
105,6
120,0
124,8
146,4

3,8
4,0
4,4
4,7
5,1
5,1
5,7
6,8
7,0
7,3
7,7
7,7
7,9
8,4
8,6
8,9
9,2
10,0
10,6
11,1
11,6
11,6
12,3

17
20
24
29
32
35
43
50
57
64
72
80
96
104
114
125
132
156
173
184
204
211
241

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

216 0003 002


216 0003 003
216 0003 004
216 0003 005
216 0003 006
216 0003 007
216 0003 008
216 0003 010
216 0003 012
216 0003 014
216 0003 016
216 0003 018
216 0003 021
216 0003 025
216 0003 027
216 0003 030
216 0003 032
216 0003 036
216 0003 040
216 0003 044
216 0003 050
216 0003 052
216 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
6 X 0,34
7 X 0,34
8 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
25 X 0,34
27 X 0,34
30 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34

6,5
9,8
13,1
16,3
19,6
22,8
26,1
32,6
39,2
45,7
52,2
58,8
68,5
82,5
88,1
97,9
104,4
117,5
130,6
143,6
163,2
169,7
199,1

4,2
4,4
4,6
5,5
5,9
5,9
6,6
7,6
7,8
7,9
8,7
8,8
10,0
10,6
10,8
11,2
11,6
12,1
12,9
13,5
14,5
14,5
15,4

24
27
33
40
45
49
63
72
80
94
106
117
146
157
172
187
199
220
244
261
304
313
358

216 0005 002


216 0005 003
216 0005 004
216 0005 005
216 0005 007
216 0005 008
216 0005 012
216 0005 014
216 0005 016
216 0005 018
216 0005 021
216 0005 025
216 0005 027
216 0005 030
216 0005 032
216 0005 036
216 0005 044
216 0005 050
216 0005 061

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
7 X 0,5
8 X 0,5
12 X 0,5
14 X 0,5
16 X 0,5
18 X 0,5
21 X 0,5
25 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
36 X 0,5
44 X 0,5
50 X 0,5
61 X 0,5

9,6
14,4
19,2
24,0
33,6
38,4
57,6
67,2
76,8
86,4
100,8
120,0
129,6
144,0
153,6
172,8
211,0
240,0
292,8

4,3
4,5
4,9
5,4
6,1
7,1
8,1
8,5
9,0
9,5
10,9
11,5
11,7
12,1
12,6
13,1
15,1
15,7
16,7

28
33
40
49
63
79
102
115
131
145
180
195
213
232
248
274
341
411
484

ConCab kabel connects the world

297

CC-data cable Li2YH-216


Halogen-free, core colour acc. to DIN 47100
Conforms to the EU low voltage guideline 73/23/EEC

Part-No.

298

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

216 0007 002


216 0007 003
216 0007 004
216 0007 005
216 0007 007
216 0007 008
216 0007 012
216 0007 014
216 0007 016
216 0007 018
216 0007 021
216 0007 024
216 0007 027
216 0007 030
216 0007 032
216 0007 036
216 0007 040
216 0007 044
216 0007 050
216 0007 052
216 0007 061

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
7 X 0,75
8 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75
18 X 0,75
21 X 0,75
25 X 0,75
27 X 0,75
30 X 0,75
32 X 0,75
36 X 0,75
40 X 0,75
44 X 0,75
50 X 0,75
52 X 0,75
61 X 0,75

14,4
21,6
28,0
36,0
50,4
58,6
86,4
100,8
115,2
129,6
151,2
180,0
194,4
216,0
230,4
259,2
288,0
316,8
360,0
374,4
439,2

4,9
5,2
5,9
6,4
7,0
8,3
9,4
10,3
10,8
11,4
12,5
13,3
13,6
14,5
15,0
15,6
16,7
17,5
18,3
18,3
19,8

38
45
58
70
87
111
142
170
192
213
248
270
297
339
360
399
443
475
530
547
648

216 0010 002


216 0010 003
216 0010 004
216 0010 005
216 0010 006
216 0010 007

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0

19,2
29,0
38,4
48,0
57,6
67,2

5,1
5,4
6,1
6,7
7,3
7,3

43
53
68
82
97
104

216 0015 002


216 0015 003
216 0015 004
216 0015 005
216 0015 006
216 0015 007

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

28,8
43,2
57,6
72,0
86,4
100,8

5,6
6,1
6,7
7,7
8,4
8,4

55
71
87
113
134
144

ConCab kabel connects the world

CC-data cable Li2YCH-247


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 247 12x0,25 Li2YCH

Technical data
Rated voltage:
m 0,14 mm2:
250 V
L 0,14 mm2:
300 V
m 0,14 mm2:
L 0,14 mm2:

The flexible CC-data cable Li2YCH-247 shielded is


suitable as a control and signal cable in data,
measurement and regulating technology.
The halogen-free and flame retardant sheath ensures
greatly improved protection for humans and materials
in the event of fire. The overall tinned copper shield
ensures reliable transmission of data and impulses and
protects against electrical interferences.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 5 Ohm X km

Construction

fixed installation:
flexible application:

Fine strands of bare copper wire, PE core insulation,


core colours acc. to DIN 47100, cores twisted in
layers, foil wrapping, overall tinned copper shield.
Outer sheath halogen-free polymer mixture, flame
retardant (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
Conductor cross-section (mm2):
Conductor resistance (Ohm/km):
Max. load (Ampere):*
* acc. to DINVDE0298 part 4

0,14
m 138
2

Test voltage:
800 V
1200 V

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 7,5 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812
0,25
m 79
4

0,34
m 57
6

0,5
m 39
9

ConCab kabel connects the world

0,75
1,0
1,5
m 26 m 19,5 m 13,3
12
15
18

299

CC-data cable Li2YCH-247


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

Part-No.

300

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

247 0001 002


247 0001 003
247 0001 004
247 0001 005
247 0001 006
247 0001 007
247 0001 008
247 0001 010
247 0001 012
247 0001 014
247 0001 016
247 0001 018
247 0001 021
247 0001 024
247 0001 025
247 0001 027
247 0001 030
247 0001 032
247 0001 036
247 0001 040
247 0001 044
247 0001 050
247 0001 052
247 0001 061

2 X 0,14
3 X 0,14
4 X 0,14
5 X 0,14
6 X 0,14
7 X 0,14
8 X 0,14
10 X 0,14
12 X 0,14
14 X 0,14
16 X 0,14
18 X 0,14
21 X 0,14
24 X 0,14
25 X 0,14
27 X 0,14
30 X 0,14
32 X 0,14
36 X 0,14
40 X 0,14
44 X 0,14
50 X 0,14
52 X 0,14
61 X 0,14

12,6
14,1
15,9
19,5
22,0
24,0
26,0
29,0
32,0
35,0
49,0
54,0
60,0
74,0
78,0
85,0
98,0
108,0
117,0
126,0
138,0
150,0
155,0
176,0

3,9
4,1
4,3
4,7
5,2
5,2
5,9
6,5
6,7
6,9
7,3
7,6
8,7
9,1
9,3
9,3
9,5
9,9
10,2
11,1
11,5
11,9
11,9
13,0

21
23
27
32
36
41
48
54
60
66
73
80
100
107
109
114
121
130
141
168
179
194
198
235

247 0002 002


247 0002 003
247 0002 004
247 0002 005
247 0002 006
247 0002 007
247 0002 008
247 0002 010
247 0002 012
247 0002 014
247 0002 016
247 0002 018
247 0002 021
247 0002 024
247 0002 025
247 0002 027
247 0002 030
247 0002 032
247 0002 036
247 0002 040
247 0002 044
247 0002 050
247 0002 052
247 0002 061

2 X 0,25
3 X 0,25
4 X 0,25
5 X 0,25
6 X 0,25
7 X 0,25
8 X 0,25
10 X 0,25
12 X 0,25
14 X 0,25
16 X 0,25
18 X 0,25
21 X 0,25
24 X 0,25
25 X 0,25
27 X 0,25
30 X 0,25
32 X 0,25
36 X 0,25
40 X 0,25
44 X 0,25
50 X 0,25
52 X 0,25
61 X 0,25

15,0
18,0
22,0
25,0
30,0
32,0
35,0
42,0
50,0
64,0
71,0
80,0
105,0
115,0
117,0
120,0
132,0
138,0
152,0
164,0
180,0
222,0
234,0
287,0

4,2
4,4
4,7
5,3
5,7
5,7
6,6
7,5
7,7
8,0
8,4
8,8
9,5
10,0
10,2
10,2
10,7
11,1
11,5
12,1
13,0
13,5
13,5
14,4

24
30
33
42
49
50
65
70
77
86
97
113
130
140
145
151
176
185
205
235
254
273
279
318

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

247 0003 002


247 0003 003
247 0003 004
247 0003 005
247 0003 006
247 0003 007
247 0003 008
247 0003 010
247 0003 012
247 0003 014
247 0003 016
247 0003 018
247 0003 021
247 0003 024
247 0003 025
247 0003 027
247 0003 030
247 0003 032
247 0003 036
247 0003 040
247 0003 044
247 0003 050
247 0003 052
247 0003 061

2 X 0,34
3 X 0,34
4 X 0,34
5 X 0,34
6 X 0,34
7 X 0,34
8 X 0,34
10 X 0,34
12 X 0,34
14 X 0,34
16 X 0,34
18 X 0,34
21 X 0,34
24 X 0,34
25 X 0,34
27 X 0,34
30 X 0,34
32 X 0,34
36 X 0,34
40 X 0,34
44 X 0,34
50 X 0,34
52 X 0,34
61 X 0,34

17,0
21,0
25,0
30,0
37,0
42,0
45,0
63,0
70,0
78,0
87,0
108,0
127,0
140,0
143,0
151,0
162,0
171,0
188,0
208,0
223,0
248,0
273,0
316,0

5,0
5,2
5,6
6,3
6,8
6,8
7,7
8,7
8,9
9,3
9,8
10,3
11,4
12,0
12,6
12,6
13,0
13,5
14,0
14,9
16,1
16,7
16,7
17,7

32
39
45
57
67
69
86
100
112
124
140
152
191
203
220
230
250
264
291
320
373
407
416
476

247 0005 002


247 0005 003
247 0005 004
247 0005 005
247 0005 006
247 0005 007
247 0005 008
247 0005 010
247 0005 012
247 0005 014
247 0005 016
247 0005 018
247 0005 021
247 0005 024
247 0005 025
247 0005 027
247 0005 030
247 0005 032
247 0005 036
247 0005 040
247 0005 044
247 0005 050
247 0005 052
247 0005 061

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
6 X 0,5
7 X 0,5
8 X 0,5
10 X 0,5
12 X 0,5
14 X 0,5
16 X 0,5
18 X 0,5
21 X 0,5
24 X 0,5
25 X 0,5
27 X 0,5
30 X 0,5
32 X 0,5
36 X 0,5
40 X 0,5
44 X 0,5
50 X 0,5
52 X 0,5
61 X 0,5

24,0
29,0
35,0
42,0
49,0
54,0
62,0
74,0
87,0
97,0
125,0
134,0
155,0
175,0
180,0
190,0
210,0
220,0
240,0
290,0
321,0
351,0
360,0
416,0

5,3
5,6
6,2
6,7
7,2
7,2
8,6
9,3
9,6
10,0
10,7
11,2
12,6
13,3
13,6
13,6
14,0
14,5
15,0
16,6
17,3
18,0
18,0
19,0

39
44
56
67
77
80
107
118
134
148
178
194
236
256
264
276
301
318
348
419
449
492
504
574

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

247 0007 002


247 0007 003
247 0007 004
247 0007 005
247 0007 006
247 0007 007
247 0007 008
247 0007 010
247 0007 012
247 0007 014
247 0007 016

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
6 X 0,75
7 X 0,75
8 X 0,75
10 X 0,75
12 X 0,75
14 X 0,75
16 X 0,75

35,0
40,0
48,0
58,0
67,0
74,0
87,0
120,0
134,0
155,0
170,0

6,0
6,4
6,9
7,5
8,1
8,1
9,7
10,7
11,0
11,5
12,6

45
60
75
86
105
110
140
165
195
210
242

247 0010 002


247 0010 003
247 0010 004
247 0010 005
247 0010 006
247 0010 007

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0

36,0
47,0
58,0
72,0
82,0
91,0

6,3
6,6
7,1
7,8
8,8
8,8

54
67
81
100
123
130

247 0015 002


247 0015 003
247 0015 004
247 0015 005
247 0015 006
247 0015 007

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

48,0
63,0
81,0
99,0
115,0
130,0

6,9
7,3
7,7
9,0
9,7
9,7

67
84
102
136
159
169

ConCab kabel connects the world

301

CC-data cable Li2YCH-(TP)-248


Halogen-free, core colour acc. to DIN 47100, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 248 2x2x0,34 Li2YCH(TP)

Technical data
Rated voltage:
m 0,14 mm2:
250 V
L 0,14 mm2:
300 V
The flexible paired CC-data cable
Li2YCH-(TP)-248 shielded is suitable as a control
and signal cable in data, measurement and regulating
technology. The halogen-free and flame retardant
sheath ensures greatly improved protection for
humans and materials in the event of fire.
Synchronized twisted core pair lenghts cause
minimum coupling values. The tinned copper shield
ensures reliable transmission of data and impulses and
protects against electrical interferences.

Construction
Fine strands of bare copper wire. PE core insulation,
core colours acc. to DIN 47100, cores twisted in pairs,
pairs twisted in layers, foil wrapping, overall tinned
copper shield. Outer sheath halogen-free polymer
mixture, flame retardant (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Conductor cross-section (mm2):


Loop resistance (Ohm/km):
Max. load (Ampere):*
* acc. to DIN VDE0298 part 4

302

m 0,14 mm2:
L 0,14 mm2:

Test voltage:
800 V
1200 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
0,34 mm2: 7-strands
Insulation resistance:
min. 5 Ohm X km
fixed installation:
flexible application:

Temperature range:
-30C to +80C
-5C to +70C

Bending radius:
fixed installation: 7,5 X cable diameter
Approvals:
acc. to DIN VDE 0281, 0812

0,14
m 276
2

0,25
m 158
4

ConCab kabel connects the world

0,34
m 114
6

0,5
m 78
9

0,75
m 52
12

Part-No.

248 0001 002


248 0001 003
248 0001 004
248 0001 005
248 0001 006
248 0001 008
248 0001 010
248 0001 012
248 0001 016
248 0001 024

No. of cores
+
cross
section

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg /km

2 X 2 X 0,14
3 X 2 X 0,14
4 X 2 X 0,14
5 X 2 X 0,14
6 X 2 X 0,14
8 X 2 X 0,14
10 X 2 X 0,14
12 X 2 X 0,14
16 X 2 X 0,14
24 X 2 X 0,14

19,1
23,4
27,8
34,9
46,2
53,4
59,0
66,0
79,0
114,0

5,2
5,7
6,5
7,0
7,2
7,8
8,9
9,7
10,5
12,8

29
35
46
51
60
70
85
96
116
172

248 0002 002 2 X 2 X 0,25


248 0002 003 3 X 2 X 0,25
248 0002 004 4 X 2 X 0,25
248 0002 005 5 X 2 X 0,25
248 0002 006 6 X 2 X 0,25
248 0002 008 8 X 2 X 0,25
248 0002 010 10 X 2 X 0,25
248 0002 012 12 X 2 X 0,25
248 0002 016 16 X 2 X 0,25

28,0
39,0
45,0
55,0
69,5
77,0
102,0
120,0
146,0

5,7
6,4
7,2
7,7
7,9
9,0
9,8
10,9
11,9

38
49
61
69
78
95
115
139
170

248 0003 002 2 X 2 X 0,34


248 0003 003 3 X 2 X 0,34
248 0003 004 4 X 2 X 0,34
248 0003 005 5 X 2 X 0,34
248 0003 006 6 X 2 X 0,34
248 0003 008 8 X 2 X 0,34
248 0003 012 12 X 2 X 0,34
248 0003 018 18 X 2 X 0,34

31,5
46,0
61,0
69,0
78,0
97,0
148,0
192,0

6,8
7,4
8,8
9,5
9,7
10,6
13,4
15,1

60
64
85
99
110
125
195
265

248 0005 002 2 X 2 X 0,5


248 0005 003 3 X 2 X 0,5
248 0005 004 4 X 2 X 0,5
248 0005 005 5 X 2 X 0,5
248 0005 006 6 X 2 X 0,5
248 0005 008 8 X 2 X 0,5
248 0005 010 10 X 2 X 0,5
248 0005 012 12 X 2 X 0,5
248 0005 018 18 X 2 X 0,5

48,0
74,0
82,0
94,0
110,0
139,0
178,0
198,0
284,0

7,2
7,9
9,4
10,2
10,4
11,4
13,2
14,4
16,9

58
73
97
112
128
162
198
233
346

248 0007 002 2 X 2 X 0,75


248 0007 003 3 X 2 X 0,75
248 0007 004 4 X 2 X 0,75
248 0007 005 5 X 2 X 0,75
248 0007 006 6 X 2 X 0,75
248 0007 008 8 X 2 X 0,75
248 0007 012 12 X 2 X 0,75
248 0007 018 18 X 2 X 0,75

58,0
84,0
108,0
128,0
146,0
180,0
261,0
390,0

8,5
9,4
10,9
11,7
12,5
13,7
17,0
19,1

85
98
130
160
195
225
335
500

ConCab kabel connects the world

303

304

305

CC-data cable Li2YCY-(TP)-245


Low capacity cable, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 245 2x2x0,34 Li2YCY(TP)

The CC-data cable Li2YCY-(TP)-245 shielded is


suitable as a link-up cable for rapid data systems up to
10 megabits per second, e.g., for interfaces
RS 422 and RS 485. It is intended to be used in
cutting and clamping technology as well as
Maxi-Termi-Point* link-up technology.

Construction
Bare 7-strands of copper wire, PE core
insulation, core colours acc. to DIN 47100, cores
paired and twisted in layers, foil wrapping, tinned
drain wire, overall tinned copper shield. PVC outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
TermiPoint: registered trademark of AMP enterprise

Part-No.

306

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

245 0002 002 2 X 2 X 0,22


245 0002 003 3 X 2 X 0,22
245 0002 004 4 X 2 X 0,22
245 0002 008 8 X 2 X 0,22
245 0002 010 10 X 2 X 0,22

23,0
29,0
34,5
70,0
78,0

6,3
6,6
7,2
8,9
10,4

47
66
81
124
165

245 0003 002 2 X 2 X 0,34


245 0003 003 3 X 2 X 0,34
245 0003 004 4 X 2 X 0,34
245 0003 008 8 X 2 X 0,34
245 0003 010 10 X 2 X 0,34

32,0
41,0
50,0
92,0
115,0

7,5
7,9
8,5
11,0
12,6

66
78
90
160
193

245 0005 002 2 X 2 X 0,5


245 0005 003 3 X 2 X 0,5
245 0005 004 4 X 2 X 0,5
245 0005 008 8 X 2 X 0,5
245 0005 010 10 X 2 X 0,5

39,0
53,0
62,0
120,0
151,0

8,3
9,3
9,5
12,3
14,6

73
112
130
225
260

Technical data
Rated voltage:
250 V
core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
7 strand copper wire
acc. to DIN VDE 0295, class 2
Capacitance at 800 Hz:
approx. 60 nF/km
Attenuation:
at 100 kHz
0,22 mm2: 9,0 dB/km
0,34 mm2: 6,5 dB/km
0,50 mm2: 6,0 dB/km
at 1 MHz
0,22 mm2: 25,0 dB/km
0,34 mm2: 20,0 dB/km
0,50 mm2: 18,0 dB/km
Impedance:
approx. 100 Ohm
Insulation resistance:
min. 5 Ohm X km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
5 X cable diameter

Approvals:
acc. to DIN VDE 0812

CC-data cable Li2YCYv-(TP)-246


Low capacity cable, shielded
Conforms to the EU low voltage guideline 73/23/EEC.

ConCab Kabel Mainhardt 246 2x2x0,34 Li2YCYv(TP)

The CC-data cable Li2YCYv-(TP)-246 shielded is suitable as a link-up cable for rapid data systems up
to 10 megabits per second, e.g., for interfaces RS 422 or RS 485. These cables are ideally suited for outdoor as well as for embedding underground. It is intended to be used in cutting and clamping
technology as well as Maxi-Termi-Point* connection technolgy.

Technical data
Rated voltage:
250 V

Construction
Bare 7-strands of copper wire, PE core insulation,
core colours acc. to DIN 47100. Cores paired and
twisted in layers, foil wrapping. Tinned drain wire,
overall tinned copper shield. PVC outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1 and IEC
60332-1).
Colour black (RAL 9005).
Termi-Point: registered trademark of AMP enterprise

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

246 0002 002 2 X 2 X 0,22


246 0002 003 3 X 2 X 0,22
246 0002 004 4 X 2 X 0,22
246 0002 008 8 X 2 X 0,22
246 0002 010 10 X 2 X 0,22

23,0
28,5
34,5
58,0
69,5

7,9
8,3
8,8
10,6
12,0

59
78
97
143
179

246 0003 002 2 X 2 X 0,34


246 0003 003 3 X 2 X 0,34
246 0003 004 4 X 2 X 0,34
246 0003 008 8 X 2 X 0,34
246 0003 010 10 X 2 X 0,34

32,0
41,0
50,0
82,0
102,0

9,2
9,5
10,2
12,6
14,3

82
94
115
180
217

246 0005 002


246 0005 003
246 0005 004
246 0005 008
246 0005 010

43,0
54,5
66,5
120,0
151,0

9,9
10,4
11,1
14,0
15,8

93
127
150
250
293

2 X 2 X 0,5
3 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5

core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
7-strand copper wires
acc. to DIN VDE 0295, class 2
Capacitance at 800 Hz:
approx. 60 nF/km
Attenuation:
at 100 kHz
0,22 mm2: 9,0 dB/km
0,34 mm2: 6,5 dB/km
0,50 mm2: 6,0 dB/km
at 1 MHz
0,22 mm2: 25,0 dB/km
0,34 mm2: 20,0 dB/km
0,50 mm2: 18,0 dB/km
Impedance:
approx. 100 Ohm
Insulation resistance:
min. 5 Ohm X km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
5 X cable diameter

Approvals:
acc. to DIN VDE 0812

307

CC-data cable LVCC-271


Data transmission cable with approval, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 271 25x2xAWG26 LVCC

The CC-data cable LVCC-271 is suitable as a data transmission cable in many areas of electronic
data processing. The overall copper shield protects from electrical interference and outside influences.
CC-computer cables LVCC are specially suitable for connectors acc. to DIN 41612 and SUB-D
(MIL C 24308) in soldering, crimping, cutting and clamping technology.

Construction
Fine strands of bare copper wire, PVC core
insulation, core colours acc. to DIN 47100, cores
paired and twisted in layers, foil
wrapping, tinned drain wire, overall tinned copper
shield, PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Technical data
AWG 28

AWG 26

AWG 24

2560

2560

2464

250 V
30 V

250 V
30 V

300 V
300 V

1.200 V

1.200 V

1.500 V

7 X 0,13

18 X 0,10

7 X 0,20

Conductor resistance: (Ohm/km)

243

138

87

Insulation resistance: min. (Ohm X km)

100

100

100

Operating capacitance: core/core approx. (pF/m)


core/shield approx. (pF/m)

100
160

120
160

100
160

UL-Style:
Rated voltage:

acc. to DIN VDE:


acc. to UL:

Test voltage: core/core


Conductor stranding:
amount of wires X wire x (mm)

Temperature range:
Bending radius:

308

-5C to +60C

-5C to +60C

15 X x

ConCab kabel connects the world

15 X x

-5C to +80C
15 X x

Part-No.

No. of cores
+

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

AWG
271 0028 005
271 0028 008
271 0028 013
271 0028 016
271 0028 019
271 0028 025
271 0028 032
271 0028 048

5 X 2 X AWG 28
8 X 2 X AWG 28
13 X 2 X AWG 28
16 X 2 X AWG 28
19 X 2 X AWG 28
25 X 2 X AWG 28
32 X 2 X AWG 28
48 X 2 X AWG 28

17,8
25,4
40,9
48,1
55,1
68,8
87,5
122,4

7,1
7,8
9,3
10,8
11,2
12,8
13,8
15,4

48
86
116
130
145
198
240
290

271 0026 002


271 0026 003
271 0026 004
271 0026 005
271 0026 006
271 0026 008
271 0026 010
271 0026 012
271 0026 016
271 0026 020
271 0026 025

2 X 2 X AWG 26
3 X 2 X AWG 26
4 X 2 X AWG 26
5 X 2 X AWG 26
6 X 2 X AWG 26
8 X 2 X AWG 26
10 X 2 X AWG 26
12 X 2 X AWG 26
16 X 2 X AWG 26
20 X 2 X AWG 26
25 X 2 X AWG 26

14,4
18,8
21,7
25,6
33,6
41,6
49,4
60,5
75,7
101,0
120,0

5,1
5,7
6,3
6,5
7,3
8,1
8,6
9,8
10,6
11,6
13,4

35
42
50
55
70
92
105
123
162
185
220

271 0024 002


271 0024 003
271 0024 004
271 0024 005
271 0024 007
271 0024 010
271 0024 012
271 0024 016
271 0024 020
271 0024 030

2 X 2 X AWG 24
3 X 2 X AWG 24
4 X 2 X AWG 24
5 X 2 X AWG 24
7 X 2 X AWG 24
10 X 2 X AWG 24
12 X 2 X AWG 24
16 X 2 X AWG 24
20 X 2 X AWG 24
30 X 2 X AWG 24

19,9
29,9
37,6
44,7
59,5
74,6
86,8
109,0
151,0
219,0

5,0
6,0
6,8
7,5
8,0
9,6
9,8
11,0
12,5
16,0

30
50
65
88
103
140
155
195
235
325

kg/km

ConCab kabel connects the world

309

CC-data cable PiMF Li2YCY-270


Low capacity, high crosstalk attenuation, shielded
Conforms to the EU low voltage guideline 73/23/EEC.

ConCab Kabel Mainhardt 270 10x2x0,34 PiMF Li2YCY

Technical data
Rated voltage:
250 V
core/core:
core/shield:
The CC-data cable PiMF Li2YCY-270
shielded is used to transfer data and signals in EDP
and control equipment. Polyethylene core pairs ensure
the transfer of large quantities of data. The metal foil
shielding of the pairs facilitates a considerable high
crosstalk attenuation. The overall tinned
copper shield ensures a reliable transmission of data
or respectively impulses at the same time protecting
against electrical interference. It is intended to be used
in cutting and clamping technology as well of
Maxi-Termi-Point* link-up technology.

Conductor stranding:
7-strand copper wire
acc. to DIN VDE 0295, class 2
Insulation resistance:
min. 5 Ohm X km
Capacitance at 800 Hz:
approx. 70 nF/km
Impedance at 1 MHz:
approx. 85 Ohm

Construction
Bare 7-strands of copper wire, PE core
insulation, core colours acc. to DIN 47100, cores
twisted in pairs, foil wrapping, tinned drain wire,
aluminium foil, shielded core pairs twisted together,
overall tinned copper shield, foil wrapping. PVC
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Crosstalk attenuation (m 1 MHz):


M 75 dB
fixed installation:

Temperature range:
-30C to +80C

Bending radius:
fixed installation: 10 X cable diameter

TermiPoint: registered trademark of AMP enterprise

Conductor cross-section (mm2):


Loop resistance (Ohm/km):
Attenuation at 100 kHz (dB/km):
at 1 MHz (dB/km):

310

Test voltage:
2000 V
1000 V

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0812
0,22
186
11,0
45,5

0,34
114
9,0
38,5

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

270 0002 002 2 X 2 X 0,22


270 0002 003 3 X 2 X 0,22
270 0002 004 4 X 2 X 0,22
270 0002 008 8 X 2 X 0,22
270 0002 010 10 X 2 X 0,22

33,0
37,0
49,0
85,0
100,0

7,0
7,5
8,1
10,0
11,8

39
57
84
135
167

270 0003 002 2 X 2 X 0,34


270 0003 003 3 X 2 X 0,34
270 0003 004 4 X 2 X 0,34
270 0003 008 8 X 2 X 0,34
270 0003 010 10 X 2 X 0,34

44,0
55,0
67,0
114,0
150,0

8,1
8,7
9,7
12,1
14,8

71
87
102
190
230

kg/km

ConCab kabel connects the world

311

CC-data cable PiMF Li2YCY-270


Low capacity, high crosstalk attenuation, shielded
Conforms to the EU low voltage guideline 73/23/EEC.

ConCab Kabel Mainhardt 270 10x2x0,5 PiMF Li2YCY

Technical data
Rated voltage:
250 V
core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
multistrand copper wires
acc. to DIN VDE 0295, class 2
up to 0,5mm2: 7-strands
from 0,75mm2: 19-strands
The CC-data cable PiMF Li2YCY-270 shielded is
used to transfer data and signals in EDP and control
equipment. Polyethylene insulated core pairs ensure
the transfer of large quantities of data. The metal foil
shielding of the pairs facilitates a considerable high
crosstalk attenuation. The overall tinned copper shield
ensure a reliable transmission of data or respectively
impulses at the same time protecting against electrical
interferences.

Construction
Bare multistrands of copper wire, PE core insulation,
core colours acc. to DIN 47100, cores twisted in pairs,
foil wrapping, tinned drain wire, aluminium foil,
shielded pairs twisted together, pairs numbered,
foil wrapping, tinned copper shield, foil wrapping,
PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).
Conductor cross-section (mm2):
Loop resistance (Ohm/km):
Attenuation at 100 kHz (dB/km):
at 1 MHz (dB/km):

312

Insulation resistance:
min. 5 Ohm X km
Capacitance at 800 Hz:
0,5 mm2: approx. 80 nF/km
1,0 mm2: approx. 95 nF/km
Impedance at 1 MHz:
0,5 mm2: approx. 80 Ohm
1,0 mm2: approx. 65 Ohm
Near-end crosstalk attenuation (m 1 MHz):
M 75 dB
fixed installation:

Temperature range:
-30C to +80C

Bending radius:
fixed installation: 10 X cable diameter
Approvals:
acc. to DIN VDE 0812
0,5
m 78
7,5
36,0

0,75
m 52
6,0
27,5

1,0
m 40
5,0
21,0

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

kg/km

270 0005 002


270 0005 004
270 0005 006
270 0005 008
270 0005 010
270 0005 016
270 0005 020
270 0005 030
270 0005 040
270 0005 050

2 X 2 X 0,5
4 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
30 X 2 X 0,5
40 X 2 X 0,5
50 X 2 X 0,5

78,0
108,0
150,0
187,0
236,0
338,0
396,0
599,0
749,0
959,0

9,5
12,0
14,3
14,9
17,5
21,3
22,9
27,9
38,0
42,5

110
172
229
262
338
448
595
842
1099
1350

270 0007 004


270 0007 006
270 0007 008
270 0007 010
270 0007 016
270 0007 020
270 0007 030

4 X 2 X 0,75
6 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
16 X 2 X 0,75
20 X 2 X 0,75
30 X 2 X 0,75

141,0
198,0
246,0
305,0
446,0
530,0
765,0

14,0
16,8
17,2
19,8
24,0
25,6
30,9

204
299
352
428
630
742
1035

270 0010 004


270 0010 006
270 0010 008
270 0010 010
270 0010 016
270 0010 020
270 0010 030

4 X 2 X 1,0
6 X 2 X 1,0
8 X 2 X 1,0
10 X 2 X 1,0
16 X 2 X 1,0
20 X 2 X 1,0
30 X 2 X 1,0

186,0
260,0
322,0
382,0
578,0
710,0
1050,0

16,2
18,7
19,2
22,2
26,9
29,4
35,4

298
386
476
563
832
1010
1405

ConCab kabel connects the world

313

CC-installation cable JE-Y(St)Y...Bd-430


For industrial electronics, core colour acc. to VDE 0815, shielded
Conforms to the EU low voltage guideline 73/23/EEC.

ConCab Kabel Mainhardt 430 4x2x0,8 JE-Y(St)Y

The CC-installation cable grey or blue JE-Y(St)Y...Bd-430 shielded is suitable as a link-up cable in
measurement, regulating, signal and data technology for fixed installation. It is suitable for cutting and
clamping technology.

Construction

Technical data

Bare solid copper wire, PVC core insulation, core


colours acc. to DIN VDE 0815, 2 cores in a pair and
4 pairs twisted in a bundle, (with 2 x 2 x 0,8 as star
quad), tinned drain wire and static shield
of aluminium foil. PVC outer sheath, flame
retardant and self-extinguishing,
(acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032) or blue (RAL 5015).

Operating peak voltage:


225 V

Part-No.

No. of cores
+
diameter
mm

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

5,0
6,0
8,0
11,0
12,5
14,0
15,0
19,0
21,5

40
60
96
158
215
280
340
525
635

5,0
6,0
8,0
11,0
12,5
14,0
15,0
19,5
21,5

40
60
96
158
215
280
340
525
635

core/core:
core/shield:

Test voltage:
500 V
2000 V

Conductor stranding:
solid copper wire
acc. to DIN VDE 0295, class 1
Insulation resistance:
min. 100 MOhm X km

kg/km

Loop resistance:
m 78 Ohm/km

grey
430 08 001 05
430 08 002 05
430 08 004 05
430 08 008 05
430 08 012 05
430 08 016 05
430 08 020 05
430 08 032 05
430 08 040 05

1 X 2 X 0,8
2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8

14,0
25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0

Capacitance at 800 Hz:


approx. 100 nF/km
Coupling at 1kHz:
max. 200 pF/100m
Attenuation at 800 Hz:
approx. 1 dB/km
Inductance:
m 0,68 mH/km

blue
430 08 001 01
430 08 002 01
430 08 004 01
430 08 008 01
430 08 012 01
430 08 016 01
430 08 020 01
430 08 032 01
430 08 040 01

314

1 X 2 X 0,8
2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8

14,0
25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0

fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
5 X cable diameter

Approvals:
acc. to DIN VDE 0815

CC-data cable JE-LiYCY... Bd-260


Core colour acc. to VDE 0815, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 260 4 x2x0,5 JE-LiYCY

Technical data
The CC-data cable JE-LiYCY... Bd-260 shielded is
ideal as a link-up cable in electronic, measurement,
control, regulating and signal technology.
In addition it is used as a data cable or respectively
as a link-up cable for telephone installations.
This cable is well suited for
Maxi-Termi-Point* technology.

Construction

Operating peak voltage:


225 V
core/core:
core/shield:

Test voltage:
500 V
2000 V

Conductor stranding:
7-strands of copper wire
acc. to DIN VDE 0295, class 2

7-strands of bare copper wire, PVC core insulation,


core colours acc. to DIN VDE 0815, 2 cores in a pair
and 4 pairs twisted in a bundle (with 2 X 2 X 0,5 as
star quad), bundles twisted in layers, foil wrapping,
tinned drain wire, overall tinned copper shield. PVC
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Capacitance at 800 Hz:


max. 100 nF/km

TermiPoint: registered trademark of AMP enterprise

Coupling at 1kHz:
max. 200 pF/100m

Loop resistance:
m 78 Ohm/km

Attenuation at 800 Hz:


approx. 1,1 dB/km

Part-No.

260 0005 002


260 0005 004
260 0005 008
260 0005 012
260 0005 016
260 0005 020
260 0005 024
260 0005 032
260 0005 040

Weight

kg/km

Outer
diameter
approx.
mm

Inductance:
approx. 0,68 mH/km

kg/km

Insulation resistance:
min. 100 MOhm X km

52,0
89,0
144,0
195,0
249,0
298,0
349,0
443,0
534,0

7,4
9,9
13,1
15,3
16,9
18,7
20,4
22,8
24,5

98
150
264
353
440
510
610
740
848

No. of cores
+
crosssection

Copper
weight

2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
32 X 2 X 0,5
40 X 2 X 0,5

fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

315

CC-data cable blue JE-LiYCY... Bd-261


Core colour acc. to VDE 0815, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 261 8x2x0,5 JE-LiYCY

Technical data

The CC-data cable JE-LiYCY...Bd-261 shielded


is suitable as a link-up cable in electronic,
measurement, control, regulating and signal
technology. Furthermore it is also used as a data cable
or respectively as a connection cable for telephone
installations. This cable is well suited for
Maxi-Termi-Point* technology.

Construction
7-strands of bare copper wire.
PVC core insulation, core colours acc. to
DIN VDE 0815, 2 cores in a pair and 4 pairs
twisted in a bundle (2 X 2 X 0,5 as star quad),
bundles twisted in layers, foil wrapping, tinned
drain wire, overall tinned copper shield. PVC outer
sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour blue (RAL 5015).

Operating peak voltage:


225 V
core/core:
core/shield:

Conductor stranding:
7-strands of copper wire
acc. to DIN VDE 0295, class 2
Loop resistance:
m 78 Ohm/km
Capacitance at 800 Hz:
max. 100 nF/km
Attenuation at 800 Hz:
approx. 1,1 dB/km

TermiPoint: registered trademark of AMP enterprise

Part-No.

261 0005 002


261 0005 004
261 0005 008
261 0005 012
261 0005 016
261 0005 020
261 0005 024
261 0005 032
261 0005 040

316

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
32 X 2 X 0,5
40 X 2 X 0,5

52,0
89,0
144,0
195,0
249,0
298,0
349,0
443,0
534,0

7,4
9,9
13,1
15,3
16,9
18,7
20,4
22,8
24,5

98
150
264
353
440
510
610
740
848

Test voltage:
500 V
2000 V

Coupling at 1kHz:
max. 200 pF/100m
Inductance:
approx. 0,68 mH/km
Insulation resistance:
min. 100 MOhm X km

kg/km

fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

CC-computer cable J-2Y(St)Y...St-III Bd-421


Low capacity, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 421 20x2x0,6 J-2Y(St)Y

Technical data

The CC-computer cable J-2Y(St)Y... St-III Bd-421


shielded is suitable as a link-up cable for data
transmission of analogue and digital signals up
to 16 Mbit/s, e.g., rapid data network for the
connection of computers, printers and monitors.
Optimized twist of the bundles lead to a greater high
crosstalk attenuation. Furthermore the static shield
protects the bundles against electronic interferences.

Rated voltage:
150 V
core/core:
core/shield:

Test voltage:
800 V
2000 V

Conductor stranding:
solid copper wire,
x 0,6 mm Q 0,28mm2

Construction
Solid bare copper wire. PE core insulation,
core colours acc. to DIN VDE 0815
(refer to appendix), 4 cores twisted to star quad,
star quad to bundles, bundles twisted in layers, drain
wire aluminum foil. PVC outer sheath, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

Insulation resistance:
min. 5 Ohm X km
Loop resistance:
m 130 Ohm/km
Capacitance at 800 Hz:
approx. 50 nF/km
Coupling at 800 Hz:
K1 approx. 420 pF/300 m
K9...K12 approx. 110 pF/300 m

Part-No.

421 06002
421 06004
421 06006
421 06008
421 06010
421 06020
421 06030
421 06040
421 06050
421 06060
421 06080
421 06100

No. of cores
+
diameter
mm

Copper
weight

2 X 2 X 0,6
4 X 2 X 0,6
6 X 2 X 0,6
8 X 2 X 0,6
10 X 2 X 0,6
20 X 2 X 0,6
30 X 2 X 0,6
40 X 2 X 0,6
50 X 2 X 0,6
60 X 2 X 0,6
80 X 2 X 0,6
100 X 2 X 0,6

13,0
24,0
35,0
46,0
58,0
116,0
172,0
229,0
286,0
342,0
455,0
568,0

kg/km

Outer
diameter
approx.
mm

Weight

5,3
7,2
7,7
8,5
9,4
12,8
14,3
15,8
16,9
18,3
22,8
27,6

40
60
80
98
110
195
280
370
415
500
640
800

kg/km

Impedance 4 MHz to 16 MHz:


85 Ohm to 115 Ohm
Attenuation:
at 1MHz: approx. 28 dB/km
at 16MHz: approx. 78 dB/km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815, 0816

317

CC-computer cable RE-2Y(St)Y-(TP)-436


Low capacity, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 436 2x2x0,5 RE-2Y(St)Y(TP)

Technical data
Operating peak voltage:
300 V
not for power application
core/core:
core/shield:

The CC-computer cable RE-2Y(St)Y-(TP)-436


shielded is suitable as a connection cable for
computer technology and process control.
Polyethylene insulated core pairs ensure
reliable rapid transmission of data.
The static shield protects the pairs from any
interference arising from surrounding
electromagnetic fields. It is suitable to be used in
intrinsically safe circuits.

Construction
Multistrand bare copper wire. PE core
insulation, black and white coloured cores with
numbering, pairs twisted in layers, tinned drain wire,
aluminium foil, PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 59265-2-1 and IEC 60332-1).
Colour blue (RAL 5015).

318

Test voltage:
2000 V
1000 V

Conductor stranding:
multistrand copper wire
acc. to DIN VDE 0295, class 2
Insulation resistance:
min. 5 GOhm X km
0,50 mm2:
1,30 mm2:

Capacitance at 800 Hz:


approx. 60 nF/km to 80 nF/km
approx. 70 nF/km to 105 nF/km
Crosstalk attenuation at 60 kHz:
M 0,85 dB/km

fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0816

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

436 05201 01
436 05202 01
436 05204 01
436 05208 01
436 05210 01
436 05212 01
436 05216 01
436 05220 01
436 05224 01
436 05236 01
436 05248 01

1 X 2 X 0,5
2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
36 X 2 X 0,5
48 X 2 X 0,5

15,0
30,0
50,0
90,0
110,0
130,0
170,0
210,0
250,0
370,0
490,0

7,4
10,0
11,2
13,6
14,7
15,7
17,4
18,6
20,2
24,0
27,4

61
115
145
215
235
280
350
395
470
656
855

436 07202 01
436 07204 01
436 07208 01
436 07210 01
436 07212 01
436 07216 01
436 07220 01
436 07224 01

2 X 2 X 0,75
4 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
12 X 2 X 0,75
16 X 2 X 0,75
20 X 2 X 0,75
24 X 2 X 0,75

35,0
65,0
125,0
154,0
185,0
245,0
298,0
365,0

10,6
11,8
14,5
16,2
16,9
18,9
20,7
22,2

130
170
265
310
355
440
525
610

436 13201 01
436 13202 01
436 13204 01
436 13206 01
436 13208 01
436 13212 01
436 13216 01
436 13224 01

1 X 2 X 1,3
2 X 2 X 1,3
4 X 2 X 1,3
6 X 2 X 1,3
8 X 2 X 1,3
12 X 2 X 1,3
16 X 2 X 1,3
24 X 2 X 1,3

31,0
62,0
114,0
168,0
218,0
322,0
426,0
684,0

8,4
11,7
13,4
16,0
17,1
19,3
21,9
26,4

92
161
233
312
375
510
650
950

436 13301 01
436 13306 01

1 X 3 X 1,3
6 X 3 X 1,3

44,0
268,0

9,5
17,6

110
425

ConCab kabel connects the world

319

CC-computer cable RE-2Y(St)Y-(TP)-437


Low capacity, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 437 2x2x0,5 RE-2Y(St)Y(TP)

Technical data
Operating peak voltage:
300 V
not for power application
core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
multistrand copper wire
acc. to DIN VDE 0295, class 2
The CC-computer cable RE-2Y(St)Y-(TP)-437
shielded is suitable as a connection cable for
computer technology and process control.
Polyethylene core pairs ensure reliable rapid
transmission of data. The static shield protects the
pairs against any electromagnetic interferences.
It can be used in- and outdoors.

Construction
Multistrand bare copper wire.
PE core insulation, black and white coloured cores
with numbering, pairs twisted in layers, tinned drain
wire, aluminium foil. PVC outer sheath, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1 resp. EN 59265-2-1 and
IEC 60332-1).
Colour black (RAL 9005).

320

Insulation resistance:
min. 5 GOhm X km
0,50 mm2:
1,30 mm2:

Capacitance at 800 Hz:


approx. 60 nF/km to 80 nF/km
approx. 70 nF/km to 105 nF/km
Crosstalk attenuation at 60 kHz:
M 0,85 dB/km

fixed installation:

Temperature range:
-30C to +80C

Bending radius:
fixed installation: 7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0816

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

437 05201 00
437 05202 00
437 05204 00
437 05208 00
437 05210 00
437 05212 00
437 05216 00
437 05220 00
437 05224 00
437 05236 00
437 05248 00

1 X 2 X 0,5
2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
36 X 2 X 0,5
48 X 2 X 0,5

15,0
30,0
50,0
90,0
110,0
130,0
170,0
210,0
250,0
370,0
490,0

7,4
10,0
11,2
13,6
14,7
15,7
17,4
18,6
20,2
24,0
27,4

61
115
145
215
245
280
350
395
470
656
855

437 07202 00
437 07204 00
437 07208 00
437 07210 00
437 07212 00
437 07216 00
437 07220 00
437 07224 00

2 X 2 X 0,75
4 X 2 X 0,75
8 X 2 X 0,75
10 X 2 X 0,75
12 X 2 X 0,75
16 X 2 X 0,75
20 X 2 X 0,75
24 X 2 X 0,75

35,0
65,0
125,0
154,0
185,0
245,0
298,0
365,0

10,6
11,8
14,5
16,2
16,9
18,9
20,7
22,2

130
170
265
310
355
440
525
610

437 13201 00
437 13202 00
437 13204 00
437 13206 00
437 13208 00
437 13212 00
437 13216 00
437 13224 00

1 X 2 X 1,3
2 X 2 X 1,3
4 X 2 X 1,3
6 X 2 X 1,3
8 X 2 X 1,3
12 X 2 X 1,3
16 X 2 X 1,3
24 X 2 X 1,3

31,0
62,0
114,0
168,0
218,0
322,0
426,0
684,0

8,4
11,7
13,4
16,0
17,1
19,3
21,9
26,4

112
161
233
312
375
510
650
950

437 13301 00
437 13306 00

1 X 3 X 1,3
6 X 3 X 1,3

44,0
268,0

9,5
17,6

110
425

ConCab kabel connects the world

321

CC-computer cable
PiMF RE-2Y(St)Y-(TP)-431
Low capacity, high crosstalk attenuation, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 431 20x2x0,5 PiMF RE-2Y(St)Y(TP)

Technical data
Operating peak voltage:
300 V
not for power application
core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
multistrand copper wire
acc. to DIN VDE 0295, class 2
Insulation resistance:
min. 5 GOhm X km
The CC-computer cable PiMF RE-2Y(St)Y-(TP)-431
shielded is suitable as a connection cable for
computer technology and process control.
Polyethylene core pairs ensure reliable rapid
transmission of data. The static shield protects the
pairs against any electromagnetic interferences.
The metal foil shielded pairs facilitate a considerable
high crosstalk attenuation. The cables with a black
sheath are suitable for outdoors and direct
burial. The type with a blue outer sheath is intended
for use in intrinsically safe circuits.

0,5 mm2:
1,3 mm2:

Capacitance at 800 Hz:


approx. 70 nF/km to 80 nF/km
approx. 95 nF/km to 105 nF/km
Impedance at 1 MHz:
0,5 mm2: approx. 80 Ohm
1,3 mm2: approx. 65 Ohm
Crosstalk attenuation at 60 kHz:
M 1 dB/km
Inductance:
m 0,65 mH/km

Construction
Multistrand bare copper wires. PE core insulation,
black and white coloured cores with numbering, cores
twisted to pairs, tinned drain wire, aluminium foil.
Shielded pairs twisted in layers, orange
communication core, tinned drain wire, aluminium
foil. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour black (RAL 9005) or colour blue (RAL 5015).

322

fixed installation:

Temperature range:
-30C to +80C

Bending radius:
fixed installation: 7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0816

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

black
431 05002 00
431 05004 00
431 05006 00
431 05008 00
431 05010 00
431 05012 00
431 05016 00
431 05020 00
431 05024 00
431 05036 00
431 05048 00

2 X 2 X 0,5
4 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
36 X 2 X 0,5
48 X 2 X 0,5

35,0
60,0
82,0
121,0
136,0
161,0
212,0
262,0
313,0
465,0
616,0

10,8
12,5
13,8
15,0
16,5
17,6
19,7
21,3
23,3
27,0
32,2

130
180
220
270
290
360
450
540
640
850
1109

431 13002 00 2 X 2 X 1,3


431 13004 00 4 X 2 X 1,3
431 13006 00 6 X 2 X 1,3
431 13008 00 8 X 2 X 1,3
431 13012 00 12 X 2 X 1,3
431 13016 00 16 X 2 X 1,3
431 13024 00 24 X 2 X 1,3

68,0
124,0
178,0
239,0
353,0
468,0
697,0

12,7
14,9
16,9
18,6
21,4
24,7
29,3

180
260
355
440
600
790
1105

blue
431 05002 01
431 05004 01
431 05006 01
431 05008 01
431 05010 01
431 05012 01
431 05016 01
431 05020 01
431 05024 01
431 05036 01
431 05048 01

2 X 2 X 0,5
4 X 2 X 0,5
6 X 2 X 0,5
8 X 2 X 0,5
10 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
20 X 2 X 0,5
24 X 2 X 0,5
36 X 2 X 0,5
48 X 2 X 0,5

35,0
60,0
82,0
121,0
136,0
161,0
212,0
262,0
313,0
465,0
616,0

10,8
12,5
13,8
15,0
16,5
17,6
19,7
21,3
23,3
27,0
32,2

130
180
220
270
290
360
450
540
640
850
1109

431 13002 01 2 X 2 X 1,3


431 13004 01 4 X 2 X 1,3
431 13006 01 6 X 2 X 1,3
431 13008 01 8 X 2 X 1,3
431 13012 01 12 X 2 X 1,3
431 13016 01 16 X 2 X 1,3
431 13024 01 24 X 2 X 1,3

68,0
124,0
178,0
239,0
353,0
468,0
697,0

12,7
14,9
16,9
18,4
21,4
24,7
29,3

180
260
355
440
600
790
1105

ConCab kabel connects the world

323

CC-process control cable RD-Y(St)Y-(TP)-432


For Maxi-Termi-Point, grey or blue, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 432 12x2x0,5 RD-Y(St)Y(TP)

Technical data
Operating peak voltage:
300 V
not for power application
core/core:
core/shield:

Test voltage:
2000 V
1000 V

Conductor stranding:
7 strand copper wire
acc. to DIN VDE 0295, class 2
Insulation resistance:
min. 100 MOhm X km
Loop resistance:
m 72 Ohm/km
The CC-process control cable RD-Y(St)Y-(TP)-432
shielded is used as a data cable for data transmission
of control centres. The static shield ensures a reliable
transmission of data and analogue signals and protects
against electrical interferences and disturbances.
These cables are intended for static wiring in closed
interiors. They are well suited for
Maxi-Termi-Point* connection technology.

Construction
7-strands of bare copper wire, PVC core insulation,
core colours acc. to DIN VDE 0815, cores twisted in
pairs with very short lay lengths, 4 pairs twisted
in a bundle, bundles identified with numbers. Bundles
twisted in layers, foil wrapping,
tinned drain wire, aluminium foil. PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7001), or blue (RAL 5015).

Capacitance at 800 Hz:


approx. 100 nF/km
Impedance:
at 1 kHz: approx. 370 Ohm
at 10 kHz: approx. 130 Ohm
Crosstalk attenuation at 10 kHz:
M 60 dB/500 m
Inductance:
m 0,73 mH/km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
7,5 X cable diameter

TermiPoint: registered trademark of AMP enterprise

324

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815, 0816

Part-No.

No. of cores
+
crosssection

Copper
weight
kg /km

Outer
diameter
approx.
mm

Weight

6,7
9,2
11,8
13,7
15,8
19,3
21,4
25,8
34,4

65
110
181
253
307
441
556
813
1571

6,7
9,2
11,8
13,7
15,8
19,3
21,4
25,8
34,4

65
110
181
253
307
441
556
813
1571

kg/km

grey
432 05002 05
432 05004 05
432 05008 05
432 05012 05
432 05016 05
432 05024 05
432 05032 05
432 05048 05
432 05096 05

2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
24 X 2 X 0,5
32 X 2 X 0,5
48 X 2 X 0,5
96 X 2 X 0,5

25,0
45,0
85,0
125,0
165,0
245,0
325,0
485,0
965,0

blue
432 05002 01
432 05004 01
432 05008 01
432 05012 01
432 05016 01
432 05024 01
432 05032 01
432 05048 01
432 05096 01

2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
24 X 2 X 0,5
32 X 2 X 0,5
48 X 2 X 0,5
96 X 2 X 0,5

25,0
45,0
85,0
125,0
165,0
245,0
325,0
485,0
965,0

ConCab kabel connects the world

325

CC-process control cable RD-Y(St)Yv-(TP)-435


For Maxi-Termi-Point, shielded
Conforms to the EU low voltage guideline 73/23/EEC

ConCab Kabel Mainhardt 435 12x2x0,5 RD-Y(St)Yv(TP)

Technical data

The CC-process control cable RD-Y(St)Yv-(TP)-435


shielded is used as a data cable for data transmission
of control centres. The static shield ensures
a reliable transmission of data and analogue signals
and protects against electrical interferences and
disturbances. These cables are for in- and outdoors as
well as for direct burial. They are well suited for
Maxi-Termi-Point* connection technology.

Construction
7-strands of bare copper wires, PVC core insulation,
core colours acc. to DIN VDE 0815, cores twisted in
pairs with very short lay length, 4 pairs twisted in a
bundle, bundles identified by numbers.
Bundles twisted in layers, foil wrapping, tinned drain
wire, aluminium foil. Reinforced PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black (RAL 9005).

Operating peak voltage:


300 V
not for power application
core/core:
core/shield:

Conductor stranding:
7 strand copper wire
acc. to DIN VDE 0295, class 2
Loop resistance:
m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx.100 nF/km

TermiPoint: registered trademark of AMP enterprise

Part-No.

435 05002 00
435 05004 00
435 05008 00
435 05012 00
435 05016 00
435 05024 00
435 05032 00
435 05048 00
435 05096 00

326

No. of cores
+
crosssection

2 X 2 X 0,5
4 X 2 X 0,5
8 X 2 X 0,5
12 X 2 X 0,5
16 X 2 X 0,5
24 X 2 X 0,5
32 X 2 X 0,5
48 X 2 X 0,5
96 X 2 X 0,5

Copper
weight
kg/ km

black
25,0
45,0
85,0
125,0
165,0
245,0
325,0
485,0
965,0

Outer
diameter
approx.
mm

Weight
kg/km

Test voltage:
2000 V
1000 V

Impedance:
at 1 kHz: approx. 370 Ohm
at 10 kHz: approx. 130 Ohm
Crosstalk attenuation at 10 kHz:
M 60 dB/500m
Inductance:
m 0,73 mH/km

8,5
10,5
13,0
15,0
17,0
19,5
22,0
27,5
36,0

95
145
240
330
400
520
720
1050
1900

fixed installation:

Temperature range:
-30C to + 80C

Bending radius:
fixed installation: 7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815, 0816

ConCab kabel verbindet

327

CC-LAN F/UTP J-02YS(St)...-(TP)-471


Twisted pairs for structured cabeling acc. to EN 50173
Overall metal foil shield

ConCab Kabel Mainhardt 471 4x2xAWG24 J-02YS(St)H(TP)

Also available pre-assembled patch


cables for Local Area Networks.
Ask for details about customized cables.

Technical data
Rated voltage:
150 V
core/core:
core/shield:

The CC-LAN F/UTP J-02YS(St)...-(TP)-471 shielded


is suitable to build information networks inside storey
buildings. Polyethylene core pairs with optimized lay
lengths ensure a rapid and reliable transmission of
high quantities of data. The static shield protects the
pairs against electromagnetic disturbances. The patch
cable facilitates the flexible connection of terminals.

Construction
Bare solid or respectively 7-strands of copper wire,
cell-PE core insulation, paired cores twisted in layers,
aluminium foil. Halogen-free polymere mixture or
PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 59265-2-1 and IEC 60332-3) or PVC basis
flame retardant and self-extinguishing (acc. to
DIN VDE 0482, part 265-2-1 and EN 50265-2-1 and
IEC 60332-1. Colour orange (RAL 2003) or grey.
Other sheath colours upon request.

328

Test voltage:
500 V
1000 V

AWG 24:
AWG 26:

Conductor stranding:
solid
7-strands

AWG 24:
AWG 26:

Loop resistance:
max. 190 Ohm/km
max. 290 Ohm/km
Impedance:
100 Ohm 15 Ohm

fixed installation:
flexible application:

fixed installation:
flexible application:

ConCab kabel connects the world

Temperature range:
-30C to +70C
-0C to +50C
Bending radius:
AWG 24
4 X cable diameter
AWG 26
8 X cable diameter
Approvals:
acc. to ISO/IEC 11801
to EN 50173-1

Part-No.

Type

No. of cores
+
AWG/diameter
mm

Sheath
material

Outer
Copper
dimension weight
approx.
mm
kg/km

Weight
kg/km

CAT 5/100 MHz


471 2404 152
471 2404 052

F/UTP
F/UTP

471 2408 152


471 2408 052

Duplex-F/UTP
Duplex-F/UTP

471 2604 152


471 2604 052

(4 X 2 X AWG24/0,52x)
(4 X 2 X AWG24/0,52x)

H
PVC

6,2x
6,2x

18
18

43
41

2 X (4 X 2 X AWG24/0,52x)
2 X (4 X 2 X AWG24/0,52x)

H
PVC

6,0 X 13,1
6,0 X 13,1

36
36

86
82

Patch cable-F/UTP (4 X 2 X AWG 26/7X0,16x)


Patch cable-F/UTP (4 X 2 X AWG 26/7X0,16x)

H
PVC

5,4x
5,4x

13
13

31
30

H
H
H

6,0x
6,0 X 12,2
5,2x

18
36
13

43
86
31

(4 X 2 X AWG 24/0,52x)
(4 X 2 X AWG 24/0,52x)

H
PVC

6,9x
6,9x

18
18

49
48

2 X (4 X 2 X AWG 24/0,52x)
2 X (4 X 2 X AWG 24/0,52x)

H
PVC

6,9 X 14,4
6,9 X 14,4

36
36

96
96

6,9x

19

CAT 5E/200 MHz


471 2404 15E2
F/UTP
(4 X 2 X AWG24/0,52x)
471 2408 15E2 Duplex-F/UTP 2 X (4 X 2 X AWG24/0,52x)
471 2604 15E2 Patch cable-F/UTP (4 X 2 X AWG 26/7X0,16x)
CAT 6/250 MHz
471 2404 162
471 2404 062

F/UTP
F/UTP

471 2408 162


471 2408 062

Duplex-F/UTP
Duplex-F/UTP

CAT 6/300 MHz


471 2404 063

F/UTP

(4 x 2 x AWG 24/0,52x)

PVC

ConCab kabel connects the world

48

329

CC-LAN SF/UTP J-02YS(St)C...-(TP)-471


Twisted pairs for structured cabling acc. to EN 50173
Overall metal foil and copper braided shield

ConCab Kabel Mainhardt 471 4x2xAWG 24 J-02YS(St)CH(TP)

Also available pre-assembled patch


cables for Local Area Networks.
Ask for details about customized cables.

Technical data
Rated voltage:
150 V
core/core:
core/shield:

The CC-LAN SF/UTP J-02YS(St)C...-(TP)-471


shielded is suitable to build information networks
inside storey buildings. Polyethylene core pairs with
optimized lay lengths ensure a rapid and reliable
transmission of high quantities of data. The static and
the copper braided shield optimally protect the pairs
from electromagnetic disturbances. The patch cable
facilitates the flexible connection of terminals.

Construction
Bare solid respectively 7-strands of copper wire,
cell-PE core insulation, paired cores twisted in layers.
Aluminum foil, tinned copper shield. Halogen-free
polymer or PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour orange (RAL 2003) or colour grey.
Other sheath colours available upon request.

330

Test voltage:
500 V
1000 V

AWG 23-24:
AWG 26:

Conductor stranding:
solid conductor
7 strands

AWG 23- 24:


AWG 26:

Loop resistance:
max. 190 Ohm/km
max. 290 Ohm/km
Impedance:
100 Ohm 15 Ohm

Temperature range:
fixed installation:
-30C to +70C
flexible application:
-5C to +50C
Bending radius:
AWG 23, 24
fixed installation: 4 X cable diameter
AWG 26
flexible application: 8 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to EN 50173

Part-No.

Type

No. of cores
+
AWG/diameter
mm

Sheath
Outer
material dimension
approx.
mm

Copper
weight

Weight

kg/km

kg/km

CAT 5/100 MHz


471 2404 153
471 2404 053

SF/UTP
SF/UTP

471 2408 153


471 2408 053

Duplex-SF/UTP
Duplex-SF/UTP

(4X2XAWG24/0,52x)
(4 X 2 XAWG24/0,52x)

H
PVC

6,5
6,5

32
32

56
54

2 X(4 X2 XAWG24/0,52x)
2 X(4 X2 XAWG26/0,52x)

H
PVC

6,5 X 13,2
6,5 X 13,2

64
64

126
120

H
H
H

6,5
6,5 X 13,2
6,0

32
64
22

63
126
43

(4 X2XAWG23/0,6x)
(4 X2 XAWG23/0,6x)

H
PVC

7,2
7,2

37
37

71
68

CAT 5E/200 MHz


471 2404 15E3
SF/UTP
(4 X2 XAWG24/0,52x)
471 2408 15E3 Duplex-SF/UTP
2 X(4 X2 XAWG24/0,52x)
471 2604 15E3 Patch cable-SF/UTP (4 X2 XAWG26/7X0,16x)
CAT 6E/350 MHz
471 2304 163
471 2304 063

SF/UTP
SF/UTP

471 2308 163


471 2308 063

Duplex-SF/UTP
Duplex-SF/UTP

2 X(4 X2 XAWG23/0,6x)
2 X(4 X2 XAWG23/0,6x)

H
PVC

14,8 X 7,3
14,8 X 7,3

74
74

154
148

471 2604 163


471 2604 063

Patch cable-SF/UTP
Patch cable-SF/UTP

(4 X2 XAWG26/7X0,16x)
(4 X2 XAWG26/7X0,16x)

H
PVC

5,7
5,7

22
22

44
43

ConCab kabel connects the world

331

CC-LAN S/FTP PiMF-J-02YS(St)C...-(TP)-471


Twisted pairs for structured cabling acc. to EN 50173
Metail foil as pair shield (PiMF) with
copper braid overall shield

ConCab Kabel Mainhardt 471 4x2xAWG 24 PiMF-J-02YS(St)CH(TP)

Also available pre-assembled patch


cables for Local Area Networks.
Ask for details about customized cables.

Technical data
Rated voltage:
150 V

The CC-LAN SF/TP PiMF J-02YS(St)C...-(TP)-471


shielded is suitable to build information networks
inside storey buildings. Polyethylene core pairs with
optimized lay lengths ensure a rapid reliable
transmission of high quantities of data. The metal foil
shielded pairs achieve a high degree of high crosstalk
attenuation (ACR). The overall tinned copper shield
facilitates reliable transmission of data respectively
impulses and protects the cable against
electromagnetic interferences. The patch cable ensures
a flexible connection of terminals.

Construction
Bare solid or resp. 7-strands of copper wire,
cell-PE core insulation, pairs twisted in layers,
aluminium foil over each pair. Shielded pairs twisted
in layers, foil. Halogen-free polymer mixture or PVC
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-3) or PVC basis flame
retardant an self extinguishing (acc. to DIN VDE
0482, part 265-2-1 and EN 50265-2-1 and IEC60
332-1). Colour orange (RAL 2003) or grey.
Other sheath colours available upon request.

332

core/core:
core/shield:

Test voltage:
500 V
1000 V

Conductor stranding:
AWG 2224:
solid
AWG 26:
7-strands
AWG 2224:
AWG 26:

Loop resistance:
max. 190 Ohm/km
max. 290 Ohm/km
Impedance:
100 Ohm 15 Ohm

Temperature range:
fixed installation:
-30C to +70C
flexible application:
-5C to +50C
Bending radius:
AWG 2224
fixed installation: 4 X cable diameter
AWG 26
flexible application: 8 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to ISO/IEC 11801
acc. to EN 50173-1

Part-No.

Type

No. of cores
+
AWG/diameter
mm

Sheath
Outer
material dimension
approx.
mm

Copper
weight

Weight

kg/km

kg/km

CAT 6/250 MHz


471 2404 164
471 2404 064

S/FTP
S/FTP

[4 X(2 XAWG24/0,52x)]
[4 X(2 XAWG24/0,52x)]

H
PVC

7,1
7,1

37
37

67
65

471 2304 164


471 2304 064

S/FTP
S/FTP

[4 X(2 XAWG23/0,56x)]
[4 X(2 XAWG23/0,56x)]

H
PVC

7,8
7,8

42
42

74
72

471 2204 164


471 2204 064

S/FTP
S/FTP

[4 X(2 XAWG22/0,64x)]
[4 X(2 XAWG22/0,64x)]

H
PVC

8,8
8,8

50
50

90
87

471 2308 164


471 2308 064

Duplex-S/FTP
Duplex-S/FTP

2 X[4 X(2 XAWG23/0,56x)]


2 X[4 X(2 XAWG23/0,56x)]

H
PVC

7,8 X 16,5
7,8 X 16,5

74
74

139
136

[4 X(2 XAWG26/7X0,16x)]
[4 X(2 XAWG26/7X0,16x)]

H
PVC

6,5
6,5

22
22

49
47

7,8

42

74

H
H
H
H

7,8
7,8 X 16,5
8,8
6,5

37
74
50
22

70
140
94
49

9,5

34

85

471 2604 164 Patch cable-S/FTP


471 2604 064 Patch cable-S/FTP

CAT 6/450 MHz


471 2304 16E4

S/FTP

(4X(2XAWG 23/0,56x))

CAT 7/600 MHz


471 2304 174
S/FTP
471 2308 174 Duplex-S/FTP
471 2204 174
S/FTP
471 2604 174 Patch cable-S/FTP

[4 X(2 XAWG23/0,56x)]
2 X[4 X(2 XAWG23/0,56x)]
[4 X(2 XAWG22/0,64x)]
[4 X(2 XAWG26/7X0,16x)]

CAT 7/1000 MHz


471 2304 57E400

S/TP-C

[4 X(2 XAWG23/0,56x)]

ConCab kabel connects the world

333

CC-LAN-cable
LAN-cable acc. to IEEE 802.3 for ETHERNET-networks

ConCab Kabel Mainhardt LAN ETHERNET

Also available pre-assembled patch


cables for Local Area Networks.
Ask for details about customized cables.
CC-LAN-cable shielded is suitable for
ETHERNET basis band transmission acc. to 10Base2
and 10Base5. These classic ETHERNET-LAN-cables
have proved their worth in many computer networks
for years. With a data transfer rate of 10MBits/s you
can achieve maximum segment lengths of 185 m with
10Base2 cables and 500m with 10Base5 cables.

Technical data
Impedance:
50 Ohm

Construction

Temperature range:
fixed installation: -25C to +70C

10Base2:
Bare 7-strands of copper inside conductor, cell-PE
core insulation, aluminium foil, tinned copper shield.
PVC outer sheath.
10Base5:
Bare copper inside conductor, cell-PE core insulation,
double aluminium foil, tinned copper shield, double
tinned copper foil and tinned copper shield.
PVC outer sheath.

Part-No.
and
reference no.

305 058 2
170 124 8
170 045 1

Type

RG 58 C/U (10Base2,
Cheapernet)
1,0L/2,7 (10Base2)
2,2/6,3 (10Base5)

Abbreviations:
Cu
=
G
=
vz
=
AlF
=

334

Attenuation Shorten- Capaat


ing
citance
10 MHz
factor
dB/100m
v/c
pF/m

4,5

0,66

101

4,4
1,8

0,81
0,81

83
81

10Base2:
10Base5:

Bending radius:
10 X cable diameter
30 X cable diameter
Approvals:
IEEE 802.3

Inside cond.
+

mm

Insulation
material+

mm

Cuvz 19 X 0,18 PE 2,95


Cu 7 X 0,35
Cu 2,17

Ext. conductor Sheath material Cu- Weight


resp.
+
weight
shield
outer-x
approx. mm kg/km kg/km

CuGvz

20,5

38

cell-PE 2,7 AlF+CuGvz


PVC 4,6
21,0
cell-PE 6,3 2XAIF+2XCuGvz PVC (yell.) 10,3 128,0

33
172

copper wire
braiding
tinned
aluminium foil

ConCab kabel connects the world

PVC 4,9

CC-LAN-cable
LAN-cable acc. IEEE 802.5 for Token-Ring-Network
acc. to IBM-standard

ConCab Kabel Mainhardt LAN TOKEN-RING

Also available pre-assembled


with connectors. Ask for details
about customized cables.
CC-LAN-cables shielded are used as data cables in
the cabling systems of the Token-Ring-Networks of
IBM with a data rate of 4MBits/s and 16MBits/s.
The A-Types are approved for data rates of up to
100MBit/s.

Technical data

Construction

acc. to IBM-specification:
Type 1 with 2 drilled 0,64mm x double cores, Type 6
with 0,40mm x copper wires, cell-PE core insulation,
core colours are red, green, orange and black. Pairs
are double shielded with aluminium foil and tinned
copper shield. PVC outer sheath.
Twinax cable:
Inside conductor out of 7-strands of tinned copper
wire, PE core insulation, cores twisted in pairs with
very short lay lengths, tinned copper shield.
PVC outer sheath.

Part-No.
and
IBMreference no.

Type

33G2772
4716734
33G2775
7362211

LAN Typ 1A
LAN Typ 1 outside
LAN Typ 6A flex.
Twinax

No. of cores
+
x / AWG
2 X2 X0,64x (AWG22/1)
2 X2 X0,64x (AWG22/1)
2 X2 X0,4x (AWG26/7)
2 XAWG20/7

Impedance
at 3 to 20MHz

q
150
150
150
105

Type 1:
Type 6:
Twinax:

Temperature range:
-10C to +70C
-35C to +85C
-10C to +60C

Type 1:
Type 6:
Twinax:

Bending radius:
75 mm
50 mm
50 mm
Approvals:
IEEE 802.5

Attenuation
at dB/100 m
atMHz
4 16 20

Ext. conductor
resp.
shield

Outer
dimension
approx.
mm

Cableweight

2,2
2,2
3,3

Al-foil, CuGvz
Al-foil, CuGvz
Al-foil, CuGvz
CuGvz

8X12
10X14
8,5x
8,3x

95
105
60
90

4,4
4,4
6,6
4,9

kg/km

Abbreviations:
CuGvz =
tinned copper wire braiding

ConCab kabel connects the world

335

CC-coaxial cable-305
CC-monitor cable-300
For high frequency analogue and digital signals

ConCab Kabel Mainhardt VIDEO 0,6/3,7

Also available pre-assembled


with sockets and connectors. Ask for
details about customized cables.

Technical data

CC-coaxial cable-305 and CC-monitor cable-300 are


used for high frequency transmission in broadcasting,
receiving stations and telecommunication equipment.
They are also used in EDP as well as in industrial and
entertainment electronics. Video and monitor cables
serve for low attenuation transmission of analogue
and digital television signals between cameras and
monitors. Special halogen-free and flame retardant
cables (FRNC) are provided for areas that need
special protection for humans and equipment
against fire.

Construction
Please refer to table for inside conductors, insulation,
outside conductors and sheaths.

336

Dielectric constants:
PE (2Y):
2,3
Cell-PE (02Y):
1,8
Hollow space-PE (2Yho):
1,5
PTFE (5Y):
2,1
FEP (6Y):
2,1
Temperature range for fixed installation:
PE (2Y): -40C to +80C
PVC (Y), FRNC(H): -25C to +70C
FEP (6Y), PTFE (5Y): -55C to +200C
Bending radius:
fixed installation: approx. 10 X cable diameter
Approvals:
RG-types acc. to MIL-C-17,
acc. to DIN 47383, 47384, 47389

ConCab kabel connects the world

Part-No.

Type

Impe- Attenuation Shorten- Capa- Inside cond.


dance
at
ing
citance
+
x
100 MHz
factor
q
dB/100 m
v/c
pF/m
mm

Insulation
material
+x
mm

Outer
conductor
resp.
shield

Sheath
material
+ outer-x
mm

Cu- Weight
weight

PE 4,70
PE 7,24
PE 2,95
PE 2,95
PE 3,70
PE 3,70
PE-hollow 3,7
PE-hollow 3,7
PE-hollow 3,7
PE-hollow 3,7

CuGvs+CuG
CuG
CuGvz
CuGvz
CuG
CuG
CuG
CuG
CuG
2XCuG

PVC 8,4
PVC 10,3
PVC 4,9
FRNC 5,0
PVC 6,2
FRNC 6,2
PVC 6,2
PUR 6,2
FRNC 6,2
PE 6,5

67,0
58,0
20,5
20,5
25,0
25,0
25,0
25,0
25,0
46,0

116
104
38
38
57
58
54
54
56
70

6,0
6,0
5,0
8,0
8,0
9,0

12
12
9
16
17
17

82,0
59,0
82,0
118,0
118,0
110,0
42,0
8,5

157
98
165
207
215
187
60
15

kg/km kg/km

RG-coaxial cable
305 006 0
305 011 0
305 058 2
305 058 3
305 059 1
305 059 2
305 062 0
305 062 1
305 062 2
305 071 1

RG6 A/U
RG11 A/U
RG58 C/U
RG58 FRNC
RG59 B/U
RG59 FRNC
RG62 A/U
RG62 PUR
RG62 FRNC
RG71 B/U

75
75
50
50
75
75
93
93
93
93

9,1
7,6
16,0
16,0
11,2
11,2
10,3
10,3
10,3
10,3

0,66
0,66
0,66
0,66
0,66
0,66
0,83
0,83
0,83
0,83

67,0
67,0
101,0
101,0
67,0
67,0
42,5
42,5
42,5
42,5

305 174 0 RG174 A/U


305 174 1 RG174U
305 178 1 RG178 B/U
305 179 1 RG179 B/U
305 187 0 RG187 A/U
305 188 0 RG188 A/U

50
50
50
75
75
50

31,0
31,0
42,8
27,9
27,9
27,8

0,66
0,66
0,7
0,7
0,7
0,7

101,0 StCu 7X0,16


101,0 StCu 7X0,16
93,0 StCuvs 7X0,1
63,0 StCuvs 7X0,1
64,0 StCuvs 7X0,1
94,0 StCuvs 7X0,16

PE 1,5
PE 1,5
FEP 0,84
FEP 1,6
FEP 1,6
PTFE 1,52

CuGvz
CUGvz
CuGvs
CuGvs
CuGvs
CuGvs

PVC 2,8
PVC 2,55
FEP 1,8
FEP 2,45
PTFE 2,6
PTFE 2,6

305 213 0
305 213 1
305 213 2
305 214 0
305 214 2
305 216 0
305 223 0
305 316 0

50
50
50
50
50
75
50
50

6,6
4,9
6,6
6,6
6,6
7,6
13,5
27,8

0,66
0,8
0,66
0,66
0,66
0,66
0,66
0,70

101,0
83,0
101,0
101,0
101,0
67,0
101,0
94,0

Cu 7X0,75
Cu 7X0,75
Cu 7X0,75
Cu 7X0,75
Cu 7X0,75
Cuvz 7X0,4
Cuvs 0,9
StCuvs 7X0,16

PE 7,24
cell-PE 6,0
PE 7,24
PE 7,24
PE 7,24
PE 7,24
PE 2,95
FEP 1,52

CuG
CuF+CuG
CuG
2XCuGvs
2XCuGvs
2XCuG
2XCuGvs
CuGvs

PVC 10,3
PE 9,0
FRNC 10,3
PVC 10,8
FRNC 10,8
PVC 10,8
PVC 5,3
FEP 2,5

RG213 U
RG213 FOAM
RG213 FRNC
RG214 U
RG214 FRNC
RG216 U
RG223 U
RG316 U

Abbreviations:
StCu
=
Cu
=
G
=
vz
=
vs
=

StCu 0,72
Cuvz 7X0,4
Cuvz 19X0,18
Cuvz 19X0,18
StCu 0,58
StCu 0,58
StCu 0,64
StCu 0,64
StCu 0,64
StCu 0,64

copper plated steel wire


copper wire
braiding
tinned
silver plated

ConCab kabel connects the world

337

CC-coaxial cable-305
CC-monitor cable-300
For high frequency analogue and digital signals

Part-No.

Type

Impedance
q

Attenuation
in dB/100 m
at MHz

Shorten- Capa- Insideing- citance conductor


factor
+ x
1750 2150 2400
v/c
pF/m
mm

Insulation
material
+ x
mm

Outer
conductor
resp.
shield

Sheath
material
+ dimensions
mm

Weight

AlF+CuGvz
AlF+CuGvz
AlF+AlG
AlF+CuGvz

PVC 4,6 x
PVC 5,0X10,3
PVC 6,7 x
PE 10,1x

26
59
35
83

AlF+CuGvz
AlF+CuGvz
AlF+CuGvz

PVC 4,6 x
PVC 7,0 x
PE 10,1 x

29
45
90

kg/km

SAT coaxial cable to 2400 MHz, double shielded


for analogue SAT-receivers
305 0630 009
305 0630 209
305 1148 009
305 1672 000

0,65/3,0
2X(0,65/3,0)
1,1/4,8
1,6/7,2

75
75
75
75

42,6
42,6
26,0
17,9

46,9
46,9
28,7
20,8

49,4
49,5
31,3
21,9

0,83
0,83
0,85
0,84

53,0
53,0
52,0
53,0

Cu 0,65
Cu 0,65
Cu 1,13
Cu 1,63

cell-PE 3,0
cell-PE 3,0
cell-PE 4,8
cell-PE 7,2

for digital SAT-receivers


305 0630 109 0,65/3,0D
305 1148 109 1,1/4,8D
305 1672 100 1,6/7,2D

Part-No.

Type

75
75
75

41,0 46,2 48,6


25,1 28,4 30,9
17,1 19,5 21,4

0,83
0,85
0,84

53,0
52,0
53,0

Cu 0,65
Cu 1,13
Cu 1,63

cell-PE 3,0
cell-PE 4,8
cell-PE 7,2

Impe- Attenuation Shorten- Capa- Inside- Insulation


Outer
Sheath material
dance
at
ing
citance conductor material conductor
+
10 MHz
factor
+x
+x
resp.
outer x
q
dB/100m
v/c
pF/m
mm
mm
shield
mm

Copper
weight

Weight

kg/km

kg/km

17,0
17,0
18,0
18,0
35,0
35,0
35,0

46
50
46
50
93
85
103

Video cable
305 0637 110
305 0637 310
305 0637 010
305 0637 210
305 1166 010
305 1166 100
305 1166 210

338

0,6/3,7
0,6/3,7 FRNC
0,6 L/3,7
0,6 L/3,7 FRNC
1,1/6,6
1,1/6,6
1,1/6,6 FRNC

75
75
75
75
75
75
75

3,4
3,5
4,4
4,5
2,0
2,0
2,1

0,66
0,66
0,66
0,66
0,66
0,66
0,66

67,0
67,0
67,0
67,0
67,0
67,0
67,0

Cu 0,60
Cu 0,60
Cu 7X0,20
Cu 7X0,20
Cu 1,0
Cu 1,0
Cu 1,0

PE 3,7
PE 3,7
PE 3,7
PE 3,7
PE 6,6
PE 6,6
PE 6,6

CuG
AlF+CuG
CuG
AlF+CuG
CuG
CuG
AlF+CuG

ConCab kabel connects the world

PVC (green) 6,1


FRNC (green) 6,1
PVC (green) 6,1
FRNC (green) 6,1
PVC (green) 8,8
PE (black) 8,8
FRNC 9,0

Part-No.

Type

shield

Impe- Attenuation Shorten- Capadance


at
ing
citance
10 MHz
factor

dB/100m

v/c

pF/m

Inside cond.
+
diameter

Insulation
material
+x

mm

mm

Outer
conductor
resp.

Coax sheath material


+
diameter

Overallshield

mm

Outer sheath
material
+ outer-x

Copper
weight

Weight

mm

kg/km

kg/km

23,0
36,0

59
88

66,0
102,0

275
398

43,5

80

Multi-Video cable/Colour-Monitor cable


300 0415 300 3X0,37/1,5
300 0415 500 5X0,37/1,5

75
75

5,8
5,8

0,81
0,81

60,0
60,0

Cu 0,37
Cu 0,37

cell-PE 1,5
cell-PE 1,5

CuGvz
CuGvz

300 0637 300 3X0,6/3,7


300 0637 500 5X0,6/3,7

75
75

3,4
3,4

0,66
0,66

67,0
67,0

Cu 0,60
Cu 0,60

PE 3,7
PE 3,7

CuG
CuG

300 0312 500 5X0,3L/1,2


flexible

75

15,6

0,81

60,0

StCuvz 7u0,10

cell-PE 1,2

CuGvz

Abbreviations:
Cu
=
G
=
vz
=
Al
=
AlF
=

PVC (red, green, blue) 2,6


PVC (red, green, blue,
white black) 2,6
PVC (red, green, blue) 6,1
PVC (red, green, blue,
white, black) 6,1
PVC (red, green, blue,
white, black) 2,2

AlF
AlF

PVC (black) 7,2


PVC (black) 9,0

AlF
AlF

PVC 16,0
PVC 19,0

Cuvz

PVC (black) 8,0

copper wire
braiding
tinned
aluminium wire
aluminium foil

ConCab kabel connects the world

339

CC-POF-cable
Halogen- and metal free plastic optical fibre cable
1 or 2 plastic fibres

ConCab Kabel Mainhardt POF 2P 980/1000

Also available pre-assembled with


connectors. Ask for information about
customized cables.

The CC-POF-cable (plastic optical fibre)


is designed for simple and economical
connection in data technoloy and field bus
applications. The maximum distance can be up to
100 m with a 660 nm wavelength depending on the
fibre attenuation. The lighter 2Y-version is prefered
for indoor use. The design with additional
PUR-sheath (11Y) is for rougher environment as well
as for power supply chains. The CC-POF-cables can
be fitted exceptionally simply and fast with the
popular POF connector systems.

Technical data
Fibre type:
PMMA-step index fibre
core diameter:
980 m
cladding diameter:
1000 m
Attenuation:
max. 200 dB/km at 650 nm

Construction
Plastic step index fibre, PE sheath, colour black.
Duplex version: Additional core sheath with core
colour marking, cores are separable.
PUR (11Y)-design: Addition PUR outer sheath,
Colour orange (RAL 2003).

Part-No.

Type

fixed installation:
flexible application:

Temperature range:
-20C to +80C
-10C to +60C

fixed installation:
flexible application:

Bending radius:
10 X cable diameter
15 X cable diameter

Dimension
mm

01 0980 0100
01 0980 0200
02 0980 0108
02 0980 0208

340

I-V2Y 1P980/1000
2,2
I-V2Y 2P980/1000 2,2 X 4,4
I-V2Y11Y 1P980/1000
5,0
I-V2Y11Y 2P980/1000
5,5

Max.
tensile
load
N

Weight

120
230
200
300

4
7
28
35

kg/km

ConCab kabel connects the world

CC-indoor fibre optic cable-0106


I-V(ZN)H, I-V(ZN)Y, I-V(ZN)H11Y, I-V(ZN)HH, I-V(ZN)YY
with 1 or 2 fibres for direct connector mounting

ConCab Kabel Mainhardt I-V(ZN)H 2G50/125

~~

The CC-indoor fibre optic cable-0106 is ideal as connection cable for indoor use as patch cable and
pigtail. The cable construction is especially designed to be adapted for direct connector mounting. The standard indoor fibre cables are halogen-free and flame retardant. Also available with an additional PUR sheath
for heavy mechanical demands and rough industrial environments.

Also available pre-assembled with


connectors. Ask for information about
customized cables.

Construction

The single cores of the duplex version are separable,


or the overall outer sheath is strippable by zip-cord
without the need of tools. Standard outer sheath
colours are grey or orange. Other outer sheath colours
upon request.

Technical data

Graded index or single mode quartz fibre, composite


tight buffer design, aramid tensile strength members.

Fibre type:
Quartz graded index fibre:
core diameter: 0 m resp. 62,5 m
cladding diameter:
25 m

I-V(ZN)H:
Outer sheath halogen-free and flame retardant.
I-V(ZN)Y:
PVC outer sheath, flame retardant.

Quartz single mode fibre:


core diameter:
9 m
cladding diameter:
125 m

I-V(ZN)H11Y:
Inner sheath halogen-free and flame retardant,
PUR outer sheath.

Composite / tight buffered fibre core:


core diameter:
0,9 mm

I-V(ZN)HH:
Inner sheath and outer sheath halogen-free, flame
retardant polymer mixture.

fixed installation:
flexible application:

I-V(ZN)YY:
PVC inner sheath and PVC outer sheath,
flame retardant.
Part-No.

Part-No.

Part-No.

G50/125

G62,5/125

E9/125

Type

Temperature range:
-5C to +60C
-5C to +50C
Bending radius:
15 X cable diameter

Fibre Dimension
amount

Weight

mm

Max.
tensile
load
N

kg/km

0106 01 050 1.. 0106 01 062 1.. 0106 01 009 1.. I-V(ZN)H
0106 02 050 1.. 0106 02 062 1.. 0106 02 009 1.. I-V(ZN)H

1
2

2,8 x
2,8 X 6

300
600

10
20

0106 01 050 0.. 0106 01 062 0.. 0106 01 009 0.. I-V(ZN)Y
0106 02 050 0.. 0106 02 062 0.. 0106 02 009 0.. I-V(ZN)Y

1
2

2,8 x
2,8 X 6

300
600

10
19

0106 02 050 2.. 0106 02 062 2.. 0106 02 009 2.. I-V(ZN)H11Y

4,5 X 7,5

600

38

0106 02 050 3.. 0106 02 062 3.. 0106 02 009 3.. I-V(ZN)HH

4,5 X 7,5

600

40

0106 02 050 4.. 0106 02 062 4.. 0106 02 009 4.. I-V(ZN)YY

4,5 X 7,5

600

39

Approvals:
acc. to DIN VDE 0888,
EN 188000
When ordering please
complete the part no.
with the following
ref- no. .. = colour
00
black
01
blue
03
red
05
grey
08
orange
09
yellow
10
green

341

CC-fibre optic-breakout cable


AT-V(ZN)HH-0104
Halogen- and metal free for direct connector mounting
4 to 18 fibres

ConCab Kabel Mainhardt AT-V(ZN)HH 12G50/125

~~

Also available pre-assembled with


connectors. Ask for information about
customized cables.

Technical data
Fibre type:
Quartz graded index fibre:
core diameter:
50 m resp. 62,5 m
cladding diameter:
125 m

The CC-fibre optic-breakout cable


AT-V(ZN)HH-0104 is suitable for simple connections
of distribution panels inside buildings as well as
outside. The classical construction with robust
simplex indoor cables provides the best possible
protection of free fibre ends in patch panels and is
easy to use for connector mounting. The halogen-free,
flame retardant outer sheath confirms to the strict fire
protection regulations for buildings.

Quartz single mode fibre:


core diameter:
9 m
cladding diameter:
125 m
Composite thight buffer fibre core:
diameter:
0,9 mm
core diameter:

Construction

Simplex indoor cable:


2,5 mm
Temperature range:
-10C to +70C
-5C to +50C

operation:
Graded, index or single mode quartz fibre,
composite tight buffer design, aramid tensile strength installation and assembly:
members. Core sheath halogen-free, flame retardant
Bending radius:
polymer mixture, cores
12 X cable diameter
identified through colour code or numerals, cores
twisted in layers. Outer sheath out of halogen-free,
Approvals:
flame retardant polymer mixture.
acc. to DIN VDE 0888, EN 188000
Colour black (RAL 9005).

342

Part-No.

Part-No.

Part-No.

G 50/125

G 62,5/125

E 9/125

0104 02 050 0
0104 04 050 0
0104 06 050 0
0104 08 050 0
0104 12 050 0
0104 16 050 0
0104 18 050 0

0104 02 062 0
0104 04 062 0
0104 06 062 0
0104 08 062 0
0104 12 062 0
0104 16 062 0
0104 18 062 0

0104 02 009 0
0104 04 009 0
0104 06 009 0
0104 08 009 0
0104 12 009 0
0104 16 009 0
0104 18 009 0

Type

AT-V(ZN)HH
AT-V(ZN)HH
AT-V(ZN)HH
AT-V(ZN)HH
AT-V(ZN)HH
AT-V(ZN)HH
AT-V(ZN)HH

Amount Outer
Max.
of
diameter tensile
fibres approx.
load
mm
N
2
4
6
8
12
16
18

8,0
8,0
10,6
12,2
13,6
15,6
15,6

ConCab kabel connects the world

1000
1000
1000
1000
1200
1600
1600

Weight
kg/km
64
100
100
140
180
200
200

CC-fibre optic minibreakout cable


I-V(ZN)H-0105
Halogen- and metal free for direct connector mounting
2 to 20 fibres

ConCab Kabel Mainhardt I-V(ZN)H 8G50/125 ~~

Also available pre-assembled with


connectors. Ask for information about
customized cables.

Technical data

The CC-fibre optic minibreakout


cable I-V(ZN)H-0105 is ideal for simple fast and economical connections in buildings e.g., patch panels,
backbones and direct link-ups to PCs. Due to the
compact dimensions of the single cores, it is easy and
economical to link-up larger distribution panels. The
halogen-free, flame retardant outer sheath of the
minibreakout cable confirms to the strict fire protection regulations for buildings.

Construction
Graded index or single mode quartz
fibre, composite tight buffer design, cores coloured
and with broken line coding, cores
twisted in layers, aramid tensile strength members,
outer sheath halogen-free and flame
retardant polymer mixture.
Colour grey.

Part-No.

Part-No.

Part-No.

G 50/125

G 62,5/125

E 9/125

0105 02 050 5
0105 04 050 5
0105 06 050 5
0105 08 050 5
0105 12 050 5
0105 16 050 5
0105 20 050 5

0105 02 062 5
0105 04 062 5
0105 06 062 5
0105 08 062 5
0105 12 062 5
0105 16 062 5
0105 20 062 5

0105 02 009 5
0105 04 009 5
0105 06 009 5
0105 08 009 5
0105 12 009 5
0105 16 009 5
0105 20 009 5

Fibre type:
Quartz graded index fibre:
core diameter: 50 m resp. 62,5 m
cladding diameter:
125 m
Quartz single mode fibre:
core diameter:
9 m
cladding diameter:
125 m
Composite tight buffer fibre core:
diameter:
0,9 mm
Temperature range:
operation:
-10C to +70C
installation and assembly:
5C to +50C
Bending radius:
12 X cable diameter
Approvals:
acc. to DIN VDE 0888, EN 188000

Type

I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H

Amount Outer
Max.
of
diameter tensile
fibres approx.
load
mm
N
2
4
6
8
12
16
20

5,5
5,5
6,0
6,0
7,0
7,2
7,2

ConCab kabel connects the world

1200
1200
1200
1200
1200
1200
1200

Weight
kg/km
28
28
33
33
47
42
42

343

CC-fibre optic universal cable-0102


A/I-D(ZN)H, A/I-D(ZN)BH, A/I-DQ(ZN)H, A/I-DQ(ZN)BH
Halogen-free 2 to 24 fibres with centralized loose tube

ConCab Kabel Mainhardt A/I-D(ZN)BH 4G50/125

~~

Also available pre-assembled with


connectors. Ask for information about
customized cables.

Technical data
The CC-fibre optic universal cable-0102
is suitable as a compact, easily mountable
economical connection of data networks for indoor as
well as outdoor areas. The halogen-free, flame retardant outer sheath ensures that the cable fulfils the
strict fire protection regulations for buildings. Due to
the central arrangement of the loose tubes, the outer
diameter is tighter and the cable weights less in comparison to the classical twisted outer cables. The
laying in tubes and ducts is much easier. The
swellable fleece respectively impregnation of the
tensile strength members makes the A/1-DQ types
100% longitudinally waterproof. Additional glass roving provide an increased cross-sectional resistance to
pressure as well as rodent protection for
the A/I-D BH types.

Construction
Graded index or single mode quartz fibre,
centralized loose tube with optional gel
filling, non-metallic tensile strength members of glass
respectively aramid roving, optional swellable. Outer
sheath of halogen-free, flame retardant polymer
mixture. Colour black (RAL 9005).

344

Fibre type:
Quartz graded index fibre
core diameter:
50 m resp. 62,5 m
cladding diameter:
125 m
Quartz single mode fibre:
core diameter:
9 m
cladding diameter:
125 m
Loose tubes:
No. of fibres
diameter
2 to 12
2,8 mm
12 to 16
3,5 mm
16 to 24
4,0 mm
operation:
installation and assembly:

Temperature range:
-30C to +70C
-5C to +50C
Bending radius:
15 X cable diameter

Approvals:
acc. to DIN VDE 0888, EN 188000

ConCab kabel connects the world

Part-No.

Part-No.

Part-No.

Type

Amount Outer
Max.
of
diameter tensile
fibres
approx.
load
mm
N

G50/125

G62,5/125

E9/125

0102 02 050 10
0102 04 050 10
0102 06 050 10
0102 08 050 10
0102 10 050 10
0102 12 050 10
0102 16 050 10
0102 24 050 10

0102 02 062 10
0102 04 062 10
0102 06 062 10
0102 08 062 10
0102 10 062 10
0102 12 062 10
0102 16 062 10
0102 24 062 10

0102 02 009 10
0102 04 009 10
0102 06 009 10
0102 08 009 10
0102 10 009 10
0102 12 009 10
0102 16 009 10
0102 24 009 10

A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H
A/I-D(ZN)H

2
4
6
8
10
12
16
24

6,0
6,0
6,0
6,0
6,0
6,0
7,0
9,0

1000
1000
1000
1000
1000
1000
1000
1000

30
30
30
30
30
30
38
61

0102 02 050 30
0102 04 050 30
0102 06 050 30
0102 08 050 30
0102 10 050 30
0102 12 050 30
0102 24 050 30

0102 02 062 30
0102 04 062 30
0102 06 062 30
0102 08 062 30
0102 10 062 30
0102 12 062 30
0102 24 062 30

0102 02 009 30
0102 04 009 30
0102 06 009 30
0102 08 009 30
0102 10 009 30
0102 12 009 30
0102 24 009 30

A/I-D(ZN)BH
A/I-D(ZN)BH
A/I-D(ZN)BH
A/I-D(ZN)BH
A/I-D(ZN)BH
A/I-D(ZN)BH
A/I-D(ZN)BH

2
4
6
8
10
12
24

8,5
8,5
8,5
8,5
8,5
8,5
9,0

1500
1500
1500
1500
1500
1500
1500

58
58
58
58
58
58
66

0102 02 050 20
0102 04 050 20
0102 06 050 20
0102 08 050 20
0102 10 050 20
0102 12 050 20
0102 24 050 20

0102 02 062 20
0102 04 062 20
0102 06 062 20
0102 08 062 20
0102 10 062 20
0102 12 062 20
0102 24 062 20

0102 02 009 20
0102 04 009 20
0102 06 009 20
0102 08 009 20
0102 10 009 20
0102 12 009 20
0102 24 009 20

A/I-DQ(ZN)H
A/I-DQ(ZN)H
A/I-DQ(ZN)H
A/I-DQ(ZN)H
A/I-DQ(ZN)H
A/I-DQ(ZN)H
A/I-DQ(ZN)H

2
4
6
8
10
12
24

8,5
8,5
8,5
8,5
8,5
8,5
9,0

1500
1500
1500
1500
1500
1500
1500

60
60
60
60
60
60
66

0102 02 050 40
0102 04 050 40
0102 06 050 40
0102 08 050 40
0102 10 050 40
0102 12 050 40
0102 24 050 40

0102 02 062 40
0102 04 062 40
0102 06 062 40
0102 08 062 40
0102 10 062 40
0102 12 062 40
0102 24 062 40

0102 02 009 40
0102 04 009 40
0102 06 009 40
0102 08 009 40
0102 10 009 40
0102 12 009 40
0102 24 009 40

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

2
4
6
8
10
12
24

11,0
11,0
11,0
11,0
11,0
11,0
11,5

2500
2500
2500
2500
2500
2500
2500

100
100
100
100
100
100
112

ConCab kabel connects the world

Weight
kg/km

345

CC-fibre optic outdoor cable-0103


A-DQ(ZN)2Y ... Lg, A-DQ(ZN)B2Y ... Lg
Halogen-free 20 to 144 fibres with twisted loose tubes

~~

~~

~~

~~

Technical data
The CC-fibre optic outdoor cable-0103 is ideal for
long distance outdoor data networks. The robust
PE outer sheath provides the best resistance to
environmental stress and ultraviolet radiation.
The outdoor cables are intended to be laid in tubes,
cable ducts and direct burial. The A-DQ types are
100% longitudinally waterproof due to the gel filling
in the core bundles as well as the swellable fleece
respectively impregnation of the non-metallic strain
relief elements. Additional glass rovings provide a
high tensile strength cross-sectional resistance
to pressure as well as rodent protection in
the A-DQ B2Y types.

Construction
Graded index or single mode quartz fibre,
gel filled loose tube, GRP rod, loose tubes twisted in
layers, non-metalic strain relief out of glass fibre or
aramid roving. PE outer sheath.
Colour black (RAL 9005).

346

Fibre type:
Quartz graded index fibre:
core diameter:
50 m resp. 62,5 m
cladding diameter:
125 m
Quartz single mode fibre:
core diameter:
9 m
cladding diameter:
125 m

diameter:

Loose tubes:
max. 12 fibres
2,8 mm to 3,0 mm

operation:
installation and assembly:

Temperature range:
-20C to +70C
-5C to +50C
Bending radius:
15 X cable diameter

Approvals:
acc. to DIN VDE 0888, EN 188000

ConCab kabel connects the world

Part-No.

Part-No.

Part-No.

Type

Amount Outer
Max. Weight
of
diameter tensile
fibres approx. load
mm
N
kg/km

G50/125

G62,5/125

E9/125

0103 020 050 20


0103 024 050 20
0103 030 050 20
0103 036 050 20
0103 040 050 20
0103 050 050 20
0103 060 050 20
0103 072 050 20
0103 080 050 20
0103 096 050 20
0103 100 050 20
0103 120 050 20
0103 144 050 20

0103 020 062 20


0103 024 062 20
0103 030 062 20
0103 036 062 20
0103 040 062 20
0103 050 062 20
0103 060 062 20
0103 072 062 20
0103 080 062 20
0103 096 062 20
0103 100 062 20
0103 120 062 20
0103 144 062 20

0103 020 009 20


0103 024 009 20
0103 030 009 20
0103 036 009 20
0103 040 009 20
0103 050 009 20
0103 060 009 20
0103 072 009 20
0103 080 009 20
0103 096 009 20
0103 100 009 20
0103 120 009 20
0103 144 009 20

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

20
24
30
36
40
50
60
72
80
96
100
120
144

14,5
14,5
14,5
15,5
14,5
14,5
14,5
16,0
16,5
16,5
17,0
18,0
20,0

3000
3000
3000
3000
3000
3000
3000
4000
4000
4000
4000
4000
4000

165
165
180
180
180
180
180
205
205
205
215
240
260

0103 020 050 40


0103 024 050 40
0103 030 050 40
0103 036 050 40
0103 040 050 40
0103 050 050 40
0103 060 050 40
0103 072 050 40
0103 080 050 40
0103 096 050 40
0103 100 050 40
0103 120 050 40
0103 144 050 40

0103 020 062 40


0103 024 062 40
0103 030 062 40
0103 036 062 40
0103 040 062 40
0103 050 062 40
0103 060 062 40
0103 072 062 40
0103 080 062 40
0103 096 062 40
0103 100 062 40
0103 120 062 40
0103 144 062 40

0103 020 009 40


0103 024 009 40
0103 030 009 40
0103 036 009 40
0103 040 009 40
0103 050 009 40
0103 060 009 40
0103 072 009 40
0103 080 009 40
0103 096 009 40
0103 100 009 40
0103 120 009 40
0103 144 009 40

A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y

20
24
30
36
40
50
60
72
80
96
100
120
144

15,5
15,5
15,5
15,5
15,5
15,5
15,5
16,5
17,5
17,5
18,0
19,0
21,0

9000
9000
9000
9000
9000
9000
9000
9000
9000
9000
9000
9000
9000

200
200
200
200
200
200
200
210
230
230
240
260
308

ConCab kabel connects the world

347

348

349

CC-telephone cable J-YY...Bd-410


Installation cable acc. to DIN VDE 0815

ConCab Kabel Mainhardt 410 40x2x0,6 J-YY Bd

Technical data
Rated voltage:
250 V
Test voltage:
800 V
Conductor stranding:
solid copper wire x 0,6 mm Q 0,28 mm2
Loop resistance:
m 130 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 100 nF/km
Coupling at 800 Hz:
K1 approx. 300 pF/100m
K9...K12 approx. 100 pF/100m
The CC-telephone cable J-YY...Bd-410 is a popular
choice for fixed installation of telephone equipment
indoors. Synchronized twisted core pair lengths cause
minimum coupling values.

Construction
Bare solid copper wire, PVC core insulation, core
colours and identification acc. to DIN VDE 0815
(section 4.4.8), 4 cores twisted to star quad, foil wrapping. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp.EN 50265-2-1 and IEC 60332-1).
Colour grey (RAL 7032).

350

Attenuation at 800 Hz:


approx. 1,5 dB/km
Temperature range:
fixed installation: -30C to +80C
Bending radius:
one-time bending without tensile force:
2,5 X cable diameter
multiple bending under tensile force
or during transport:
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

Part-No.

410 06 001
410 06 002
410 06 004
410 06 006
410 06 010
410 06 016
410 06 020
410 06 024
410 06 030
410 06 040
410 06 050
410 06 060
410 06 080
410 06 100

No. of cores
+
diameter
mm

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

1 X 2 X 0,6
2 X 2 X 0,6
4 X 2 X 0,6
6 X 2 X 0,6
10 X 2 X 0,6
16 X 2 X 0,6
20 X 2 X 0,6
24 X 2 X 0,6
30 X 2 X 0,6
40 X 2 X 0,6
50 X 2 X 0,6
60 X 2 X 0,6
80 X 2 X 0,6
100 X 2 X 0,6

5,7
11,0
23,0
34,0
57,0
90,0
113,0
138,0
170,0
226,0
283,0
339,0
452,0
565,0

4,5
4,8
6,8
7,1
8,3
10,7
11,9
12,3
13,5
14,8
16,1
17,6
20,5
22,5

26
35
60
75
100
165
201
228
285
362
439
518
685
840

kg/km

ConCab kabel connects the world

351

CC-telephone cable J-Y(St)Y...Lg-420


Installation cable acc. to VDE 0815, shielded

ConCab Kabel Mainhardt 420 8x2x0,6 J-Y(St)Y Lg

Technical data
Rated voltage:
250 V
Test voltage:
800 V
Conductor stranding:
solid copper wire x 0,6 mm Q 0,28 mm2
solid copper wire x 0,8 mm Q 0,50 mm2
Loop resistance:
x 0,6 mm m 130 Ohm/km
x 0,8 mm m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 100 nF/km

The CC-telephone cable J-Y(St)Y...Lg-420 is a


popular choice for fixed installation of
telephone equipment indoors. Synchronized twisted
core pair lengths cause minium coupling values.
The static shield enables it to be used where a greater
need for electromagnetic compatibility (EMC) is.

Construction
Bare, solid copper wire, PVC core insulation, core
colours acc. to DIN VDE 0815 (section 4.4.5), cores
twisted in pairs, pairs twisted in layers, copper drain
wire, aluminium laminated foil. PVC outer sheath,
flame retardant and self-extinguishing (acc. to DIN
VDE 0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Colour grey (RAL 7032).

352

Coupling at 800 Hz:


K1 approx. 300 pF/100m
Attenuation at 800 Hz:
x 0,6 mm approx. 1,7 dB/km
x 0,8 mm approx. 1,1 dB/km
Temperature range:
fixed installation:
-30C to +80C
Bending radius:
one-time bending without tensile force:
2,5 X cable diameter
multiple bending under tensile force
or during transport:
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

Part-No.

No. of cores
+
diameter
mm

Copper
weight

Outer
diameter
approx.
mm

Weight

420 06 001
1 X 2 X 0,6
420 06 002
2 X 2 X 0,6
420 06 003
3 X 2 X 0,6
420 06 004
4 X 2 X 0,6
420 06 005
5 X 2 X 0,6
420 06 006
6 X 2 X 0,6
420 06 008
8 X 2 X 0,6
420 06 010 10 X 2 X 0,6
420 06 012 12 X 2 X 0,6
420 06 014 14 X 2 X 0,6
420 06 016 16 X 2 X 0,6
420 06 020 20 X 2 X 0,6
420 06 024 24 X 2 X 0,6
420 06 030 30 X 2 X 0,6
420 06 040 40 X 2 X 0,6
420 06 050 50 X 2 X 0,6
420 06 060 60 X 2 X 0,6
420 06 080 80 X 2 X 0,6
420 06 100 100 X 2 X 0,6

6,9
13,0
18,0
24,0
30,0
35,0
46,0
58,0
71,0
82,0
93,0
116,0
139,0
172,0
229,0
286,0
342,0
455,0
568,0

5,0
5,5
6,3
6,8
7,2
7,5
8,0
9,0
9,5
10,0
10,5
11,0
11,5
13,0
15,0
17,0
18,0
20,5
23,0

30
40
50
60
70
80
90
110
130
145
160
190
220
280
350
430
500
640
850

420 08 001
1 X 2 X 0,8
420 08 002
2 X 2 X 0,8
420 08 003
3 X 2 X 0,8
420 08 004
4 X 2 X 0,8
420 08 005
5 X 2 X 0,8
420 08 006
6 X 2 X 0,8
420 08 008
8 X 2 X 0,8
420 08 010 10 X 2 X 0,8
420 08 012 12 X 2 X 0,8
420 08 014 14 X 2 X 0,8
420 08 016 16 X 2 X 0,8
420 08 020 20 X 2 X 0,8
420 08 024 24 X 2 X 0,8
420 08 030 30 X 2 X 0,8
420 08 040 40 X 2 X 0,8
420 08 050 50 X 2 X 0,8
420 08 060 60 X 2 X 0,8
420 08 080 80 X 2 X 0,8
420 08 100 100 X 2 X 0,8

11,0
21,0
31,0
41,0
52,0
62,0
82,0
102,0
123,0
144,0
164,0
204,0
244,0
304,0
405,0
506,0
606,0
807,0
1008,0

6,0
7,0
8,5
9,0
9,5
10,5
11,5
13,0
14,0
14,5
15,5
16,5
19,0
20,0
22,5
25,5
28,0
31,0
32,0

40
60
80
100
120
140
170
220
250
280
320
380
460
560
710
900
1050
1400
1750

kg/km

kg/km

ConCab kabel connects the world

353

CC-fire alarm cable J-YY...Bd-481


Installation cable, red outer sheath

ConCab Kabel Mainhardt 481 Brandmeldekabel J-YY Bd

Technical data
Rated voltage:
250 V
Test voltage:
800 V
Conductor stranding:
solid copper wire x 0,6 mm Q 0,28 mm2
The CC-fire alarm cable J-YY...Bd-481 is used for
fixed installations preferably for signal transmission in
both dry and damp rooms as well as on protected
walls outdoors. The cable is marked at regular intervals with the printed word Brandmeldekabel
(fire alarm cable).

Loop resistance:
m 130 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 100 nF/km

Construction
Bare, solid copper wire, PVC core insulation, core
colours and bundle identification acc. to DIN VDE
0815 (section 4.4.8), 4 cores twisted to star quad, foil
wrapping. PVC outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour red (RAL 3000).

Part-No.

481 06 001
481 06 002
481 06 004
481 06 006

354

No. of cores
+
diameter
mm

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

1 X 2 X 0,6
2 X 2 X 0,6
4 X 2 X 0,6
6 X 2 X 0,6

5,7
11,0
23,0
34,0

4,5
4,8
6,8
7,1

26
35
60
75

kg/km

Coupling at 800 Hz:


K1 approx. 300 pF/100m
K9...K12 approx. 100 pF/100m
Attenuation at 800 Hz:
approx. 1,5 dB/km
Temperature range:
fixed installation:
-30C to +80C
Bending radius:
one-time bending without tensile force:
2,5 X cable diameter
multiple bending under tensile force
or during transport:
7,5 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

CC-fire alarm cable J-Y(St)Y...Lg-480


Installation cable with red outer sheath
RoHS

ConCab Kabel Mainhardt 480 Brandmeldekabel J-Y(St)Y Lg

The CC-fire alarm cable J-Y(St)Y...Lg-480 is used


in fixed installations preferably for signal
transmission in both dry and damp rooms as well as
on protected walls outdoors. The cable is printed at
regular intervals with the word Brandmeldekabel
(fire alarm cable). The static shield enables it to meet
the high requirements on electromagnetic
compatibility (EMC).

Technical data

Construction

Conductor stranding:
solid copper wire x 0,6 mm Q 0,28 mm2
solid copper wire x 0,8 mm Q 0,50 mm2

Bare, solid copper wire, PVC core insulation, core


colours acc. to DIN VDE 0815 (section 4.4.5), core
pairs twisted in layers, copper drain wire, aluminium
foil. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour red (RAL 3000).
Part-No.

No. of cores
+
diameter
mm

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

480 06 001
480 06 002
480 06 004
480 06 006
480 06 010
480 06 020

1 X 2 X 0,6
2 X 2 X 0,6
4 X 2 X 0,6
6 X 2 X 0,6
10 X 2 X 0,6
20 X 2 X 0,6

6,9
13,0
24,0
35,0
58,0
116,0

4,5
5,3
6,6
7,6
9,1
11,0

30
40
60
80
110
190

480 08 001
480 08 002
480 08 003
480 08 004
480 08 005
480 08 006
480 08 008
480 08 010
480 08 012
480 08 016
480 08 020
480 08 024
480 08 030
480 08 040
480 08 050
480 08 060

1 X 2 X 0,8
2 X 2 X 0,8
3 X 2 X 0,8
4 X 2 X 0,8
5 X 2 X 0,8
6 X 2 X 0,8
8 X 2 X 0,8
10 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
24 X 2 X 0,8
30 X 2 X 0,8
40 X 2 X 0,8
50 X 2 X 0,8
60 X 2 X 0,8

11,0
21,0
31,0
41,0
52,0
62,0
82,0
102,0
123,0
164,0
204,0
244,0
304,0
405,0
506,0
606,0

5,5
6,1
8,0
8,7
9,4
10,1
11,0
13,1
13,5
14,8
15,6
18,4
19,4
20,9
23,7
25,8

40
60
80
100
120
140
170
220
250
300
380
460
522
670
840
980

kg/km

Rated voltage:
250 V
Test voltage:
800 V

Loop resistance:
x 0,6 mm m 130 Ohm/km
x 0,8 mm m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 100 nF/km
Coupling at 800 Hz:
K1 approx. 300 pF/100m
K9...K12 approx. 100 pF/100m
Attenuation at 800 Hz:
x 0,6 mm approx. 1,7 dB/km
x 0,8 mm approx. 1,1 dB/km
Temperature range:
fixed installation:
-30C to +80C
Bending radius:
one-time bending without tensile force:
2,5 X cable diameter
multiple bending under tensile force
or during transport:
7,5 X cable diameter
Approvals:
acc. to DIN VDE 0815

355

CC-fire alarm cable E30/FE180


JE-H(St)H...Bd-484
Halogen-free with electrical function E30 acc. to DIN 4102
Insulation integrity FE180 acc. to IEC 60331

ConCab Kabel Mainhardt 484 Brandmeldekabel E30/FE180 JE-H(St)H Bd

Technical data
Rated voltage:
150 V
core/core:
core/shield:

Test voltage:
500 V
2000 V

Conductor stranding:
solid copper wire x 0,8 mm Q 0,5 mm2
Loop resistance:
m 72 Ohm/km

The CC-fire alarm and emergency cable


JE-H(St)H...Bd-484 is used for signal
transmission in fire alarms and ELA
equipment where a particular need for the function
and insulation performance requirements of this cable
is. The halogen-free and flame retardant insulation
and sheath mixture comforms to the IEC/DIN norms.
The cable is preferably used for signal transmission in
dry and damp rooms as well as on protected
walls outdoors.

Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 120 nF/km
Coupling at 800 Hz:
approx. 300 pF/100m

Construction
Bare, solid copper wire, special halogen-free flame
retardant, polymer core insulation, core and bundle
identification acc. to DIN VDE 0815 (section 4.4.6),
cores twisted in pairs, 4 pairs twisted to bundles,
bundles twisted in layers, copper drain wire,
aluminium foil, glass fibre tape. Outer sheath
halogen-free, flame retardant polymer mixture
(acc. to IEC 60332-3). Colour red (RAL 3000) or
orange. Red cable with print
Brandmeldekabel (fire alarm cable).

356

Attenuation at 800 Hz:


m 1,2 dB/km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
6 X cable diameter

Approvals:
acc. to DIN VDE 0815
corresponds to DIN 4102, IEC 60331

ConCab kabel connects the world

Part-No.

No. of cores
+
diameter
mm

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
529,0

8,0
10,5
15,0
17,0
20,0
21,0
27,0
29,0
33,0

76
130
232
320
430
510
745
962
1195

25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
529,0

8,0
10,5
15,0
17,0
20,0
21,0
27,0
29,0
33,0

76
130
232
320
430
510
745
962
1195

kg/km

red
484 08002 33
484 08004 33
484 08008 33
484 08012 33
484 08016 33
484 08020 33
484 08032 33
484 08040 33
484 08052 33

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8
orange

484 08002 38
484 08004 38
484 08008 38
484 08012 38
484 08016 38
484 08020 38
484 08032 38
484 08040 38
484 08052 38

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8

ConCab kabel connects the world

357

CC-fire alarm cable E90/FE180


JE-H(St)H...Bd-485
Halogen-free with electrical function E90 acc. to DIN 4102
Insulation integrity FE180 acc. to IEC 60331

ConCab Kabel Mainhardt 485 Brandmeldekabel E90/FE180 JE-H(St)H Bd

Technical data
Rated voltage:
150 V
core/core:
core/shield:

Test voltage:
500 V
2000 V

Conductor stranding:
solid copper wire x 0,8 mm Q 0,5 mm2
The CC-fire alarm and emergency cable
JE-H(St)H...Bd-485 is used for signal
transmission in fire alarms and ELA equipment where
a particular need for the function and insulation
performance requirements of this cable is.
The halogen-free and flame retardant insulation and
sheath mixture conforms to the IEC-/DIN norms.
The cable is preferably used for signal transmission in
dry and damp rooms as well as on protected
walls outdoors.

Loop resistance:
m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 120 nF/km
Coupling at 800 Hz:
approx. 300 pF/100m

Construction
Bare, solid copper wire, special halogen-free and
flame retardant polymer core insulation, core and
bundle identification acc. to DIN VDE 0815 (section
4.4.6), cores twisted in pairs, 4 pairs twisted to
bundles, bundles twisted in layers, copper drain wire,
aluminium foil, glass fibre tape. Outer sheath
halogen-free, flame retardant polymer
mixture (acc. to IEC 60332-3).
Colour red (RAL 3000) or orange.
Red cable with print Brandmeldekabel
(fire alarm cable).

358

Attenuation at 800 Hz:


m 1,2 dB/km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
6 X cable diameter

Approvals:
acc. to DIN VDE 0815
corresponds to DIN 4102, IEC 60331

ConCab kabel connects the world

Part-No.

No. of cores
+
diameter
mm

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

8,0
10,5
15,0
17,0
20,0
21,0
27,0
29,0
33,0

76
130
232
320
430
510
745
962
1195

8,0
10,5
15,0
17,0
20,0
21,0
27,0
29,0
33,0

76
130
232
320
430
510
745
962
1195

kg/km

red
485 08002 93
485 08004 93
485 08008 93
485 08012 93
485 08016 93
485 08020 93
485 08032 93
485 08040 93
485 08052 93

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8

25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
529,0

orange
485 08002 98
485 08004 98
485 08008 98
485 08012 98
485 08016 98
485 08020 98
485 08032 98
485 08040 98
485 08052 98

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
16 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8

25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
529,0

ConCab kabel connects the world

359

CC-fire alarm cable E90/FE180


JE-H(St)H RH...Bd-483
Halogen-free with electrical function E90 acc. to DIN 4102
Insulation integrity FE180 acc. to IEC 60331, steel wire braiding

ConCab Kabel Mainhardt 483 Brandmeldekabel E90/FE180 JE-H(St)H RH Bd

Technical data
Rated voltage:
150 V
core/core:
core/shield:

Test voltage:
500 V
2000 V

Conductor stranding:
solid copper wire x 0,8 mm Q 0,5 mm2
The CC-fire alarm and emergency cable
JE-H(St)H RH...Bd-483 is used for signal
transmission in fire alarm and ELA equipment with
higher function and insulation performance
requirements. The overall steel wire braid gives the
cable more protection against mechanical strain.
The cable is preferably used for signal transmission in
dry and damp rooms as well as on protected walls
outdoors.

Loop resistance:
m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 120 nF/km
Coupling at 800 Hz:
approx. 300 pF/100m

Construction
Bare, solid copper wire, special halogen-free and
flame retardant polymer core insulation, core and
bundle identification acc. to DIN VDE 0815 (section
4.4.6), cores twisted in pairs, 4 pairs twisted to
bundles, bundles twisted in layers, copper drain wire,
aluminium foil. Inner sheath halogen-free, polymer
mixture, galvanized steel wire braid. Outer sheath
halogen-free, flame retardant
polymer mixture (acc. to IEC 60332-3).
Colour red (RAL 3000) or orange.
Red cable with print Brandmeldekabel
(fire alarm cable).

360

Attenuation at 800 Hz:


m 1,2 dB/km
fixed installation:

Temperature range:
-30C to +80C

fixed installation:

Bending radius:
6 X cable diameter

Approvals:
acc. to DIN VDE 0815
corresponds to DIN 4102, IEC 60331

ConCab kabel connects the world

Part-No.

No. of cores
+
diameter
mm

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

10,4
14,7
21,2
22,8
26,9
34,6
40,6
43,7

152
277
544
600
868
1359
1798
2040

10,4
14,7
21,2
22,8
26,9
34,6
40,6
43,7

152
277
544
600
868
1359
1798
2040

kg/km

red
483 08002 93
483 08004 93
483 08008 93
483 08012 93
483 08020 93
483 08032 93
483 08040 93
483 08052 93

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8

25,0
45,0
85,0
126,0
206,0
327,0
407,0
529,0
orange

483 08002 98
483 08004 98
483 08008 98
483 08012 98
483 08020 98
483 08032 98
483 08040 98
483 08052 98

2 X 2 X 0,8
4 X 2 X 0,8
8 X 2 X 0,8
12 X 2 X 0,8
20 X 2 X 0,8
32 X 2 X 0,8
40 X 2 X 0,8
52 X 2 X 0,8

25,0
45,0
85,0
126,0
206,0
327,0
407,0
529,0

ConCab kabel connects the world

361

CC-telephone cable J-H(St)H...Bd-421


Halogen-free installation cable acc. to DIN VDE 0815

ConCab Kabel Mainhardt 421 6x2x0,8 J-H(St)H Bd

Technical data
Rated voltage:
250 V
Test voltage:
800 V
Conductor stranding:
solid copper wire x 0,6 mm Q 0,28 mm
solid copper wire x 0,8 mm Q 0,5 mm
2
2

Loop resistance:
x 0,6 mm m 130 Ohm/km
x 0,8 mm m 72 Ohm/km

The CC-telephone cable J-H(St)H...Bd-421


is preferably used for the installation of fixed
telephone equipment indoors. The halogen-free and
flame retardant insulation and sheath mixture provide
increased protection for humans and materials in the
event of fire. Synchronized twisted core pair lengths
cause minimum coupling values. The static shield
enables it to be used where a greater need for
electromagnetic compatibility (EMC) is.

Construction
Bare, solid copper wire, halogen-free polymer mixture
core insulation, core and bundle identification
acc. to DIN VDE 0815 (section 4.4.8), 4 cores twisted
to star quad, 4 in a bundle, bundles twisted in layers,
copper drain wire, aluminium foil. Outer sheath
halogen-free, flame retardant polymer mixture
(acc. to IEC 60332-3).
Colour grey (RAL 7032).

362

Insulation resistance:
min. 100 MOhm X km
Capacitance at 800 Hz:
approx. 110 nF/km
Coupling at 800 Hz:
K1 approx. 300 pF/100m
K9...K12 approx. 100 pF/100m
Attenuation at 800 Hz:
x 0,6 mm: approx. 1,7 dB/km
x 0,8 mm: approx. 1,1 dB/km
Temperature range:
fixed installation:
-30C to +70C
Bending radius:
fixed installation: 6 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

Part-No.

No. of cores
+
diameter
mm

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

421 06002 05
2 X 2 X 0,6
421 06004 05
4 X 2 X 0,6
421 06006 05
6 X 2 X 0,6
421 06010 05 10 X 2 X 0,6
421 06020 05 20 X 2 X 0,6
421 06030 05 30 X 2 X 0,6
421 06040 05 40 X 2 X 0,6
421 06050 05 50 X 2 X 0,6
421 06060 05 60 X 2 X 0,6
421 06080 05 80 X 2 X 0,6
421 06100 05 100 X 2 X 0,6

14,0
25,0
37,0
59,0
126,0
172,0
229,0
286,0
342,0
455,0
568,0

7,5
9,0
10,0
12,0
15,0
17,5
20,0
21,5
23,5
26,5
29,5

60
100
110
160
270
370
450
550
660
820
1000

421 08002 05
2 X 2 X 0,8
421 08004 05
4 X 2 X 0,8
421 08006 05
6 X 2 X 0,8
421 08010 05 10 X 2 X 0,8
421 08020 05 20 X 2 X 0,8
421 08030 05 30 X 2 X 0,8
421 08040 05 40 X 2 X 0,8
421 08050 05 50 X 2 X 0,8
421 08060 05 60 X 2 X 0,8
421 08080 05 80 X 2 X 0,8
421 08100 05 100 X 2 X 0,8

25,0
45,0
65,0
106,0
206,0
307,0
407,0
508,0
608,0
809,0
1010,0

8,5
10,5
12,5
15,0
19,0
22,0
25,5
27,5
29,5
33,5
37,5

80
140
170
250
430
600
770
940
1120
1440
1800

kg/km

ConCab kabel connects the world

363

CC-fire alarm cable J-H(St)H...Bd-482


Halogen-free installation cable, red outer sheath, shielded
without defined electrical function time acc. to DIN VDE 0815

ConCab Kabel Mainhardt 482 20x2x0,8 J-H(St)H Bd Brandmeldekabel

Technical data
Rated voltage:
250 V
Test voltage:
800 V
Conductor stranding:
solid copper wire x 0,8 mm Q 0,5 mm2

The CC-fire alarm cable J-H(St)H...Bd-482


is used for fixed installation perferably for
signal transmission in dry and damp rooms as well as
on protected walls outdoors.
The cable is printed at regular intervals with
Brandmeldekabel (fire alarm cable).
The static shield enables it to meet the requirements
of electromagnetic compatibility (EMC). The
halogen-free and flame retardant insulation and sheath
mixture provide a better protection for humans and
materials in the event of fire.

Loop resistance:
x 0,8 mm m 72 Ohm/km
Insulation resistance:
min. 100 MOhm X km
Capacity at 800 Hz:
approx. 110 nF/km
Coupling at 800 Hz:
K1 approx. 300 pF/100m
K9...K12 approx. 100 pF/100m
Attenuation at 800 Hz:
approx. 1,1 dB/km

Construction
Bare, solid copper wire, halogen-free polymer mixture core insulation, core and bundle identification
acc. to DIN VDE 0815 (section 4.4.8),
4 cores twisted to star quad, 4 in a bundle, bundles
twisted in layers, copper drain wire, aluminium foil.
Outer sheath halogen-free, flame retardant polymer
mixture (acc. to IEC 60332-3).
Colour red (RAL 3000).

364

Temperature range:
fixed installation: -30C to +70C
Bending radius:
fixed installation: 6 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0815

Part-No.

No. of cores
+
diameter

482 08002 03
2 X 2 X 0,8
482 08004 03
4 X 2 X 0,8
482 08006 03
6 X 2 X 0,8
482 08010 03 10 X 2 X 0,8
482 08020 03 20 X 2 X 0,8
482 08030 03 30 X 2 X 0,8
482 08040 03 40 X 2 X 0,8
482 08050 03 50 X 2 X 0,8
482 08060 03 60 X 2 X 0,8
482 08080 03 80 X 2 X 0,8
482 08100 03 100 X 2 X 0,8

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

25,0
45,0
65,0
106,0
206,0
307,0
407,0
508,0
608,0
809,0
1010,0

8,5
10,5
12,0
15,0
19,0
22,0
25,5
27,5
29,5
33,5
37,5

80
140
170
250
430
600
770
940
1120
1440
1800

kg/km

ConCab kabel connects the world

365

CC-telephone outdoor cable


A-2Y(L)2Y...St III Bd-440

The CC-telephone outdoor cable


A-2Y(L)2Y...St III Bd-440 is intended to be
used as a location connection cable for local
networks and for private branch equipment
as well as for cabling in the ground, in cable
channels and pipes. It is not permitted for
power application. The CC-telephone
outdoor cable fulfils the stipulations of
Deutsche Telekom AG and DIN VDE 0816.

Construction
Bare solid copper wire, PE core insulation,
core identification acc. to DIN VDE 0816,
4 cores twisted to star quad, 5 quads twisted
in a main bundle, main bundle formed to
cable core centre, paper tape bandage,
laminated sheath of aluminium coated plastic
tape, PE outer sheath. The cable is marked
with metre marks and a sequence of
telephone receivers painted in white abrasion
resistant colour. Colour black.

366

Technical data
Conductor diameter (mm):
Cross-section (mm2):
Rated voltage (V):
Test voltage (V) core/core:
core/shield:
Attenuation at 800 Hz (dB/km):
Operating capacity at 800 Hz (nF/km):
Loop resistance (Ohm/km):
Coupling k1(pF/300m):
Coupling k9-12(pF/300m):
Insulation resistance:
Temperature range:
Bending radius:

ConCab kabel connects the world

0,6
0,8
0,28
0,5
225
225
500
500
2000
2000
1,0
0,8
max. 52
max. 55
max. 130
max. 73,2
98% < 400
98% < 100
min. 5 G Ohm X km
m 70C
10 X cable diameter

Part-No.

No. of
core pairs

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

A-2Y(L)2Y... X 2 X 0,6 St III Bd


440 06 002
440 06 004
440 06 006
440 06 010
440 06 020
440 06 030
440 06 040
440 06 050
440 06 070
440 06 100
440 06 150
440 06 200
440 06 250
440 06 300
440 06 350
440 06 400
440 06 500

2
4
6
10
20
30
40
50
70
100
150
200
250
300
350
400
500

11,0
23,0
34,0
57,0
113,0
170,0
226,0
283,0
396,0
565,0
848,0
1131,0
1414,0
1696,0
1979,0
2262,0
2827,0

10,5
11,0
11,5
13,0
16,0
18,0
19,5
21,0
23,5
27,0
32,5
36,5
39,5
42,5
47,5
50,5
53,5

80
125
130
165
265
355
440
525
705
950
1345
1755
2140
2525
2950
3340
4090

A-2Y(L)2Y... X 2 X 0,8 St III Bd


440 08 002
440 08 004
440 08 006
440 08 010
440 08 014
440 08 020
440 08 030
440 08 040
440 08 050
440 08 060
440 08 070
440 08 080
440 08 100
440 08 150
440 08 200
440 08 250
440 08 300
440 08 350
440 08 400
440 08 500
440 08 600

2
4
6
10
14
20
30
40
50
60
70
80
100
150
200
250
300
350
400
500
600

20,0
40,0
60,0
101,0
141,0
201,0
302,0
402,0
503,0
603,0
702,0
804,0
1005,0
1508,0
2010,0
2514,0
3016,0
3520,0
4025,0
5027,0
6035,0

12,5
13,0
13,5
15,0
16,5
18,0
21,0
23,5
25,0
27,0
28,5
29,5
32,5
40,0
47,5
51,5
54,5
58,5
63,0
69,0
74,0

100
160
175
235
296
390
540
680
835
965
1110
1250
1515
2205
2920
3580
4230
4950
5570
6965
8260

ConCab kabel connects the world

367

CC-telephone outdoor cable


A-2YF(L)2Y...St III Bd-450
with petrolat jelly filling

The CC-telephone outdoor cable


A-2YF(L)2Y...St III Bd-450 can be used as a
location connection cable for local networks
and for private branch equipment as well as
for cabling in the ground, in cable channels
and pipes. It is not permitted for power
application. The CC-telephone outdoor
cable fulfils the requirements of
Deutsche Telekom AG and DIN VDE 0816.

Construction
Bare, solid copper wire,
PE core insulation, core identification
acc. to DIN VDE 0816 (see appendix),
4 cores twisted to start quad, 5 quads twisted
in a main bundle, main bundles formed to
cable core centre. The hollow space of the
cable is filled with petrolat jelly. Paper tape
bandage, laminated sheath of aluminium
coated plastic tape, PE outer sheath. The
cable is marked with metre marks and a
sequence of telephone receivers painted in
white abrasion resistant colour. Colour black.

368

Technical data
Conductor diameter (mm):
Cross-section(mm2):
Rated voltage (V):
Test voltage (V) core/core:
core/shield:
Attenuation at 800 Hz (dB/km):
Operating capacity at 800 Hz (nF/km):
Loop resistance (Ohm/km):
Coupling k1(pF/300m):
Coupling k9-12(pF/300m):
Insulation resistance:
Temperature range:
Bending radius:

ConCab kabel connects the world

0,6
0,8
0,28
0,5
225
225
500
500
2000
2000
1,0
0,8
max. 52
max. 55
max. 130
max. 73,2
98% < 400
98% < 100
min. 5 G Ohm X km
m 70C
10 X cable diameter

Part-No.

No. of
core pairs

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

A-2YF(L)2Y... X 2 X 0,6 St III Bd


450 06 002
450 06 004
450 06 006
450 06 010
450 06 020
450 06 030
450 06 040
450 06 050
450 06 070
450 06 100
450 06 150
450 06 200
450 06 250
450 06 300
450 06 350
450 06 400
450 06 500

2
4
6
10
20
30
40
50
70
100
150
200
250
300
350
400
500

11,0
23,0
34,0
57,0
113,0
170,0
226,0
283,0
396,0
565,0
848,0
1131,0
1414,0
1696,0
1979,0
2262,0
2827,0

7,5
9,2
12,0
14,0
17,5
20,0
22,5
24,5
25,5
31,5
38,0
43,5
48,5
50,0
55,5
61,0
66,5

82
115
140
190
310
430
545
660
895
1225
1780
2315
2895
3480
3980
4485
5470

A-2YF(L)2Y... X 2 X 0,8 St III Bd


450 08 002
450 08 004
450 08 006
450 08 010
450 08 020
450 08 030
450 08 040
450 08 050
450 08 070
450 08 100
450 08 150
450 08 200
450 08 250
450 08 300
450 08 350
450 08 400
450 08 500

2
4
6
10
20
30
40
50
70
100
150
200
250
300
350
400
500

20,0
40,0
60,0
101,0
201,0
302,0
402,0
503,0
704,0
1005,0
1508,0
2010,0
2513,0
3016,0
3520,0
4025,0
5027,0

9,0
10,5
14,0
15,5
19,5
22,5
25,5
27,5
31,5
36,5
45,5
51,5
58,0
62,0
68,5
74,0
82,5

110
190
195
275
475
665
860
1050
1420
1985
2935
3750
4650
5550
6755
7640
9550

ConCab kabel connects the world

369

370

CC-compensating cable-800
Thermo element connection for temperature measurement

ConCab kabel Mainhardt 800 4x1,5 AGL-LiY(St)Y

Technical data
Conductor stranding:
solid/multi strand wires
0,22 mm2:
7 X 0,20 mm
0,5 mm2:
16 X 0,20 mm
or solid wire:
1 X 0,80 mm
0,75 mm2:
24 X 0,20 mm
1,5 mm2:
48 X 0,20 mm
or solid wire:
1 X 1,38 mm
The CC-compensating cable-800 is used to transfer
temperature measurement with thermo elements in
order to connect the route segment between the
temperature indicator and the measuring point without
any measuring mistake. The compensating cable
(AGL) consists of a pair of conductors that produce
the same thermal tension within the temperature range
of 0C to +200C as the thermal pair.

Insulation resistance:
min. 10 MOhm X km
fixed installation:

Y
Yw
2G
Y
Yw
2G

flexible application:

Construction

Temperature range:
-20C to +80C
-10C to +105C
-20C to +200C
-5C to +70C
+5C to +90C
-20C to +180C

Conductor of thermo element conductors or alternative materials, core and sheath insulation, shielding,
etc. see parts table, 4 cores with paired numbering.

Bending radius:
7,5 X cable diameter (single pair)
15 X cable diameter (stranded conductor)
20 X cable diameter (with metal braiding)

Type of elements:
iron/constantan, nickel-chrome/nickel,
platinum-rhodium/platinum

Approvals:
DIN 43710 to 43714 (old), DIN 43722,
DIN IEC 584

Thermo pair
+pole
iron
FE
nickel-chrome
NiCr
platinum-rhodium
PtRh

-pole
constantan
CuNi
nickel
Ni
platinum
Pt

nickel-chrome
NiCR

constantan
CuNi

platinum-rhodium platinum
Pt30Rh
rhodium
Pt6Rh

Colour identification
DIN IEC 584
CC-Nr.
ID letter

+pole and sheath

-pole

DIN 43710 (old)


CC-Nr.
ID letter

+pole -pole and sheath

black

white

red

blue

green

white

red

green

R/S

orange

white

red

white

EX

violet

white

BC

grey

white

ConCab kabel connects the world

371

CC-compensating cable-800
Thermo element connection to temperature measurement

Part-No.

Type

Core
insulation

Shield
and
outer sheath

Dimension Weight
approx.
mm

kg/km

Single pair compensating cable


800 0 15 01 0 .
800 0 15 01 1 .

AGL-2 X (LiY 1,5)


AGL-2 X (Li2G 1,5)

PVC
silicone

(twisted in pairs)
(twisted in pairs)

5,5
5,5

40
40

800 0 02 01 2 .
800 0 05 01 2 .
800 0 07 01 2 .
800 0 15 01 2 .

AGL-LiYY 2 X 0,22
AGL-LiYY 2 X 0,5
AGL-LiYY 2 X 0,75
AGL-LiYY 2 X 1,5

PVC
PVC
PVC
PVC

PVC (round)
PVC (round)
PVC (round)
PVC (round)

3,8
5,5
6,1
7,1

21
44
54
76

800 0 02 01 3 .
800 0 05 01 3 .
800 0 07 01 3 .

AGL-Li2G2G 2 X 0,22
AGL-Li2G2G 2 X 0,5
AGL-Li2G2G 2 X 0,75

silicone
silicone
silicone

silicone (round)
silicone (round)
silicone (round)

4,0
5,6
6,2

23
42
53

800 0 15 01 3 .
800 0 02 01 4 .
800 0 15 01 4 .

AGL-Li2G2G 2 X 1,5
AGL-LiYCY 2 X 0,22
AGL-LiYCY 2 X 1,5

silicone
PVC
PVC

silicone (round)
tinned Cu-shielded, PVC
tinned Cu-shielded, PVC (round)

7,1
5,0
8,0

75
32
92

800 0 02 01 5 .
800 0 15 01 5 .
800 0 02 01 6 .
800 0 15 01 7 .
800 0 15 01 8 .
800 0 15 01 9 .

AGL-Li2GC2G 2 X 0,22
AGL-Li2GC2G 2 X 1,5
AGL-Li2G2G-GL 2 X 0,22
AGL-Li2G-GL 2 X 1,5
AGL-Li2G2G 2 X 1,5
AGL-Li2G2GS 2 X 1,5

silicone
silicone
silicone
silicone
silicone
silicone

5,9
8,3
4,6
3,3 X 6,0
4,3 X 7,0
5,2 X 8,0

800 0 15 01 A .

AGL-Li2G(St)2G 2 X 1,5

silicone

tinned Cu-shielded, silicone


tinned Cu-shielded, silicone (round)
silicone, glass-fibre braiding (round)
glass-fibre braiding(oval)
silicone (oval)
silicone, galvanized steel wire
braiding (oval)
laminated foil, silicone (round)

800 0 15 01 B . AGL-LiY(St)Y 2 X 1,5


800 0 15 01 C . AGL-LiYY 2 X 1,5
800 0 15 01 D . AGL-LiYYSY 2 X 1,5
800 0 15 01 E .

AGL-Li2G-GLS 2 X 1,5

800 0 02 01 F . AGL-Li6Y2G 2 X 0,22


800 0 07 01 G . AGL-Li6Y(St)6Y 2 X 0,75
800 0 15 01 H . AGL-LiGL-GL 2 X 1,5

PVC
PVC
PVC

laminated foil, PVC (round)


PVC (oval)
PVC, galvanized steel wire
braiding, PVC (round)
silicone glass-fibre braiding, galvanized
steel wire braiding (oval)
FEP
silicone
FEP
FEP
glass-fibre glass-fibre braiding

Upon request we can offer above mentioned types also as multicore compensating cable.

372

ConCab kabel connects the world

8,0

50
117
24
58
60
88
85

8,0
4,3 X 7,0
9,8

86
61
148

4,1 X 6,8

75

4,5
4,2
3,5

20
42
70

Part-No.

Type

Thermo
Core
pair
insulation

Shield
and
outer sheath

Outer
diameter
approx.
mm

Weight

8,0
10,0
11,4
12,9
13,4
15,2
16,5
19,2
21,0
24,2

118
178
239
285
312
423
510
575
778
1080

11,0
13,5
14,1
17,5
19,0

200
295
405
505
600

26,2
29,0

1190
1405

kg/km

Non-shielded multi-pair compensating cables


800 0 15 02 2 .
800 0 15 03 2 .
800 0 15 04 2 .
800 0 15 05 2 .
800 0 15 06 2 .
800 0 15 08 2 .
800 0 15 10 2 .
800 0 15 12 2 .
800 0 15 16 2 .
800 0 15 20 2 .

AGL-LiYY 4 X 1,5
AGL-LiYY 6 X 1,5
AGL-LiYY 8 X 1,5
AGL-LiYY 10 X 1,5
AGL-LiYY 12 X 1,5
AGL-LiYY 16 X 1,5
AGL-LiYY 20 X 1,5
AGL-LiYY 24 X 1,5
AGL-LiYY 32 X 1,5
AGL-LiYY 40 X 1,5

2
3
4
5
6
8
10
12
16
20

PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC

Shielded multi-pair compensating cables

800 0 15 02 D .
800 0 15 03 D .
800 0 15 04 D .
800 0 15 06 D .
800 0 15 08 D .
800 0 15 12 D .
800 0 15 16 D .
800 0 15 20 D .

AGL-LiYYSY 4 X 1,5
AGL-LiYYSY 6 X 1,5
AGL-LiYYSY 8 X 1,5
AGL-LiYYSY 12 X 1,5
AGL-LiYYSY 16 X 1,5
AGL-LiYYSY 24 X 1,5
AGL-LiYYSY 32 X 1,5
AGL-LiYYSY 40 X 1,5

2
3
4
6
8
12
16
20

PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC

all types:
PVC galvanized steel
wire braiding
PVC
PVC round

In addition we can supply compensating cables according to your specifications in all well-known foreign norms
providing the order meets the minimum quantity.

Part-No.

800-

Conductor stranding
0
stranded
1
solid
Cross-section
02
0,22 mm2
05
0,5 mm2 (0,8 mm)
07
0,75 mm2
15
1,5 mm2 (1,38 mm)
No. of pairs
Cable type
Core insulation, shield, outer sheath please refer to parts table
Thermo pair/colour identification
Refer to CC-No. in the table on page 371

ConCab kabel connects the world

373

Colour code of Thermocouple Extension


Symbol
of
couple

Material combinations
+

Ext.

T
U
J
L
E

Cu
Cu
Fe
Fe
NiCr
NiCr

Fe
Cu

Cu Ni

Cu Ni

Cu Ni
Ni

Pt13Rh
Pt10Rh

Pt
Pt

Comp.

JX
-25C to
+200C

LX
0C to
+200C

EX
-25C to
+200C

KX
-25C to
+200C

KX
-25C to
+200C

KCA
0C to
+150C

3)

SoNiCr-SoNi
0C to
+200C

3)

DINIEC
(SoPtRhSoPt
0C to
+200C

KCB
0C to
+100C

NX
-25C to
+200C

NC
0C to
+150C

A 0C to
+100C

SCA/RCA

B 0C to
+200C

SCB/RCB

2)

374

Colour code

UX
0C to
+200C

Cu Ni

R
S

DIN 43714

TX
-25C to
+100C

Cu Ni

Ni Si

DIN 43710
DIN 43713

Comp. Ext.

Cu Ni

NiCrSi

Pt30Rh

Colour code

Cu Ni

DIN EN 60584
DIN 43714
draft 7/90

DIN IEC 584


DIN 43722

Pt6Rh

1) DIN IEC 584-Issue 92


2) To DIN 43710/85
3) Sequenzes SoNiCr will be replaced according to
DIN 43713 draft 8/91 DIN IEC 584

BC
0C to
+100C

4) Standard was cancelled. Cables for intrinsecally safe


circuits can wear blue sheats in accordance with
thermocouples stripes

and Compensating cables

ANSI MC 96.1

Ext.

Colour code

BS 4937

Comp. Ext.

Colour code

NF C 42-324

Comp. Ext.

Colour code

Comp.

TX
0C to
+100C

TX
0C to
+100C

TX
-25C to
+250C

TC
-25C to
+100C

JX
0C to
+200C

JX
0C to
+200C

JX
-25C to
+250C

JC
-25C to
+250C

EX
0C to
+200C

EX
0C to
+200C

EX
-25C to
+250C

EC
-25C to
+250C

KX
0C to
+200C

KX
0C to
+200C

KX
-25C to
+250C

KC
-25C to
+200C

WC
-25C to
+200C

SX
0C to
+200C

VX
0C to
+100C

VC
-25C to
+100C

SX
0C to
+200C

SC
-25C to
+200C

BX
0C to
+100C

KX Thermocouple Extension
KPX = positive conductor for THL KX
KNX = negative conductor for THL KX

BC
-25C to
+200C

KCA Compensating cables


KPCA = positive conductor for AGL KC
KPCA = negative conductor for AGL KC
(A=0/+100"C)

375

376

CC-flexible rubber cable


H05RR-F-710 | H05RN-F-720 | H07RN-F/A07RN-F-730
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 730 5G1,5 H07RN-F

H05RR-F:
Light flexible rubber cable to be used with light
working appliances and manual devices for
light mechanical tasks in dry and damp rooms.
H05RN-F:
Intermediate flexible rubber cable to be used
with light working appliances and manual
devices for light mechanical tasks in dry and
damp rooms as well as outdoors and in water
for industrial purposes.
H07RN-F/A07RN-F:
Heavy flexible rubber cable to be used with
heavy working appliances and manual devices.
It is ideal for dry and damp rooms as well as
outdoors and in water for industrial purposes.

Construction
H05RR-F:
Fine strands of bare copper wire, core insulation out of rubber mixture EI 4, core colours
acc. to DIN VDE 0293 part 308, 3 cores or
more with green/yellow protective conductor.
Cores twisted together, outer sheath out of rubber mixture EM3. Colour black.
H05RR-F

Rated voltage:
Test voltage:
Conductor stranding:
Core insulation:
Outer sheath:
Insulation resistance:
Temperature range:
Bending radius
Fixed installation:
Flexible application:
Approvals:

H05RN-F:
Bare, fine strands of copper wire, core insulation out of rubber mixture EI 4, core colours
acc. to DIN VDE 0293 part 308, 3 cores or
more with green/yellow protective conductor,
cores twisted together.
Outer sheath out of rubber
mixture EM 2 (Neoprene), flame retardant
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50262-2-1 and IEC 60332-1). Colour black.
H07RN-F/A07RN-F:
Bare, fine strands of copper wire, core insulation out of rubber mixture EI 4, core colours
acc. to DIN VDE 0293 part 308, 3 cores or
more with green/yellow protective conductor.
Cores twisted together. Outer sheath out of
rubber mixture EM 2 (Neoprene), flame
retardant (acc. to DIN VDE 0482,
part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.
Approvals:
acc. to DIN VDE 0282, part 4, HD 22.4 S3
A07RN-F (CENELEC approved
national type).
H05RN-F

H07RN-F
A07RN-F
300/500 V
300/500 V
450/750 V
2000 V
2000 V
2500 V
Fine copper strands acc. to VDE 0295, class 5
Rubber mixture EI 4
Rubber mixture
Rubber mixture
Rubber mixture
EM 3
EM 2
EM 2
min. 10 MOhm X km
-25C to +60C
-25C to +60C
-25C to +60C
3 X cables x
6 X cables x

3 X cables x
6 X cables x

3 X cables x
6 X cables x

acc. to DIN VDE 0282, part 4, HD 22.4 S3

377

CC-flexible rubber cable


H05RR-F-710 | H05RN-F-720 | H07RN-F/A07RN-F-730
Conforms to the EC low voltage guideline 73/23/EEC

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

H07 RN-F/AO7 RN-F

H05 RR-F
710 0007 002
710 0007 003
710 0007 004
710 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
29,0
36,0

5,7 - 7,4
6,5 - 8,8
6,8 - 8,8
7,6 - 9,9

67
77
98
110

730 0010 002


730 0010 003
730 0010 004
730 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,0
29,0
38,0
48,0

7,7 - 10,0
8,3 - 10,7
9,2 - 11,4
10,2 - 13,1

89
111
146
173

710 0010 002


710 0010 003
710 0010 004
710 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,0
29,0
38,0
48,0

6,1 - 8,0
7,5 - 8,5
7,1 - 9,3
8,0 - 10,3

75
93
115
135

710 0015 002


710 0015 003
710 0015 004
710 0015 005

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

29,0
43,0
58,0
72,0

7,6 - 9,8
8,0 - 10,4
9,0 - 11,6
9,8 - 12,7

114
140
175
215

710 0025 002


710 0025 003
710 0025 004
710 0025 005

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5

48,0
72,0
96,0
120,0

9,0 - 11,6
9,6 - 12,4
10,7 - 13,8
11,9 - 15,3

161
198
250
310

730 0015 001


730 0015 002
730 0015 003
740 0015 003
730 0015 004
740 0015 004
730 0015 005
730 0015 007
730 0015 012
730 0015 019
730 0015 024
730 0015 027
730 0015 037

1 X 1,5
2 X 1,5
3 G 1,5
3 X 1,5*
4 G 1,5
4 X 1,5*
5 G 1,5
7 G 1,5
12 G 1,5
19 G 1,5
24 G 1,5
27 G 1,5
37 G 1,5

14,4
29,0
43,0
43,0
58,0
58,0
72,0
101,0
173,0
274,0
346,0
385,0
530,0

5,7 - 7,1
8,5 - 11,0
9,2 - 11,9
9,2 - 11,9
10,2 - 13,1
10,2 - 13,1
11,2 - 14,4
14,0 - 17,0
17,6 - 22,4
21,5 - 24,0
24,3 - 30,7
25,5 - 31,5
27,8 - 35,2

59
128
157
157
192
192
238
371
516
788
950
1077
1395

730 0025 001


730 0025 002
730 0025 003
740 0025 003
730 0025 004
740 0025 004
730 0025 005
730 0025 007
730 0025 012
730 0025 019
730 0025 024
730 0025 027

1 X 2,5
2 X 2,5
3 G 2,5
3 X 2,5*
4 G 2,5
4 X 2,5*
5 G 2,5
7 G 2,5
12 G 2,5
19 G 2,5
24 G 2,5
27 G 2,5

24,0
48,0
72,0
72,0
96,0
96,0
120,0
168,0
288,0
456,0
576,0
638,0

6,3 - 7,9
10,2 - 13,1
10,9 - 14,0
10,9 - 14,0
12,1 - 15,5
12,1 - 15,5
13,3 - 17,0
16,0 - 19,0
20,6 - 26,2
24,4 - 30,9
28,8 - 36,4
30,0 - 33,5

72
177
217
217
269
269
329
499
719
1068
1350
1521

730 0040 001


730 0040 002
730 0040 003
740 0040 003
730 0040 004
730 0040 005

1X4
2X4
3G4
3 X 4*
4G4
5G4

38,0
77,0
115,0
115,0
154,0
192,0

7,2 - 9,0
11,8 - 15,1
12,7 - 16,2
12,7 - 16,2
14,0 - 17,9
15,6 - 19,9

99
249
298
298
373
466

H05 RN-F
720 0007 002
720 0007 003

2 X 0,75
3 G 0,75

14,4
21,6

5,7 - 7,4
6,2 - 8,1

80
95

720 0010 002


720 0010 003

2 X 1,0
3 G 1,0

19,0
29,0

6,1 - 8,0
6,5 - 8,5

95
115

* A07RN-F

378

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

H07 RN-F/A07 RN-F


730 0060 001
730 0060 002
730 0060 003
740 0060 003
730 0060 004
740 0060 004
730 0060 005

1X6
2X6
3G6
3 X 6*
4G6
4 X 6*
5G6

58,0
115,0
173,0
173,0
230,0
230,0
288,0

7,9 - 9,8
13,1 - 16,8
14,1 - 18,0
14,1 - 18,0
15,7 - 20,0
15,7 - 20,0
17,5 - 22,2

130
327
407
407
514
514
640

730 0100 001


730 0100 002
730 0100 003
740 0100 003
730 0100 004
740 0100 004
730 0100 005

1 X 10
2 X 10
3 G 10
3 X 10*
4 G 10
4 X 10*
5 G 10

96,0
192,0
288,0
288,0
384,0
384,0
480,0

9,5 - 11,9
17,7 - 22,6
19,1 - 24,2
19,1 - 24,2
20,9 - 26,5
20,9 - 26,5
22,9 - 29,1

200
586
716
716
898
898
1107

730 0160 001


730 0160 002
730 0160 003
740 0160 003
730 0160 004
740 0160 004
730 0160 005

1 X 16
2 X 16
3 G 16
3 X 16*
4 G 16
4 X 16*
5 G 16

154,0
308,0
461,0
461,0
614,0
614,0
768,0

10,8 - 13,4
20,2 - 25,7
21,8 - 27,6
21,8 - 27,6
23,8 - 30,1
23,8 - 30,1
26,4 - 33,3

278
810
1008
1008
1253
1253
1564

730 0250 001


730 0250 003
740 0250 003
730 0250 004
740 0250 004
730 0250 005

1 X 25
3 G 25
3 X 25*
4 G 25
4 X 25*
5 G 25

240,0
720,0
720,0
960,0
960,0
1200,0

12,7 - 15,8
26,1 - 33,0
26,1 - 33,0
28,9 - 36,6
28,9 - 36,6
32,0 - 40,4

396
1451
1451
1846
1846
2291

730 0350 001


730 0350 003
740 0350 003
730 0350 004
740 0350 004
730 0350 005
740 0350 005

1 X 35
3 G 35
3 X 35*
4 G 35
4 X 35*
5 G 35
5 X 35*

336,0
1008,0
1008,0
1344,0
1344,0
1680,0
1680,0

14,3 - 17,9
29,3 - 37,1
25,3 - 37,1
32,5 - 41,1
32,5 - 41,1
37,0 - 45,0
37,0 - 45,0

520
1901
1901
2393
2393
2895
2895

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

730 0500 001


730 0500 003
740 0500 003
730 0500 004
740 0500 004
730 0500 005

1 X 50
3 G 50
3 X 50*
4 G 50
4 X 50*
5 G 50

480,0
1440,0
1440,0
1920,0
1920,0
2400,0

16,5 - 20,6
34,1 - 42,9
34,1 - 42,9
37,7 - 47,5
37,7 - 47,5
42,0 - 52,0

719
2580
2580
3284
3284
4025

730 0700 001


730 0700 003
740 0700 003
730 0700 004
730 0700 005

1 X 70
3 G 70
3 X 70*
4 G 70
5 G 70

672,0
2016,0
2016,0
2688,0
3360,0

18,6 - 23,3
38,4 - 48,3
38,4 - 48,3
42,7 - 54,0
47,0 - 58,5

947
3386
3386
4331
5340

730 0950 001


730 0950 003
740 0950 003
730 0950 004

1 X 95
3 G 95
3 X 95*
4 G 95

912,0
2736,0
2736,0
3648,0

20,8 - 26,0
43,3 - 54,0
43,3 - 54,0
48,4 - 61,0

1230
4433
4433
5712

730 1200 001


730 1200 003
730 1200 004

1 X 120
3 G 120
4 G 120

1152,0
3456,0
4608,0

22,8 - 28,6
47,4 - 60,0
53,0 - 66,0

1520
5182
6828

730 1500 001


730 1500 004

1 X 150
4 G 150

1440,0
5760,0

25,2 - 31,4
58,0 - 73,0

1887
8319

730 1850 001


730 1850 004

1 X 185
4 G 185

1776,0
7104,0

27,6 - 34,4 2274


64,0 - 80,0 10062

730 2400 001

1 X 240

2304,0

30,6 - 38,3

2955

730 3000 001

1 X 300

2880,0

33,5- 41,9

3585

* A07RN-F

ConCab kabel connects the world

379

CC-rubber cable NSGAFU-350


Short circuit-proof cable 1,8/3kV acc. to VDE 0250

ConCab kabel Mainhardt 350 NSGAFU

Technical data
Rated voltage:
1,8/3 kV

The CC-rubber cable NSGAFU-350 is


particulary suited as a short circuit-proof cable in rail
and bus vehicles as well as in dry rooms. Cables with
a rated voltage of at least 1.8/3 kV are considered to
be short circuit-proof and short to earth-proof in
switching equipment and distributors up to 1000 V.

Construction
Tinned fine strands of copper wire, rubber based
insulation. Outer sheath on rubber basis, oil resistant
and flame retardant
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.

380

Test voltage:
6000 V
Conductor stranding:
Fine copper strands
acc. to DIN VDE 0295, class 5
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-25C to +80C

fixed installation:
flexible application:

Bending radius:
6 X cable diameter
10 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 602

ConCab kabel connects the world

Part-No.

350 0015
350 0025
350 0040
350 0060
350 0100
350 0160
350 0250
350 0350
350 0500
350 0700
350 0950
350 1200
350 1500
350 1850
350 2400

Crosssection

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0
480,0
672,0
912,0
1155,0
1440,0
1776,0
2305,0

7,0
7,5
9,0
9,5
11,0
13,0
15,0
16,5
18,0
20,5
24,0
26,0
28,0
31,0
34,5

47
59
77
97
153
214
324
421
564
758
995
1253
1540
1862
2428

ConCab kabel connects the world

381

CC-rubber cable NSHXAF-358


Halogen-free short circuit-proof cable 1,8/3kV

ConCab kabel Mainhardt 358 NSHXAF 1,8/3 kV

Technical data
Rated voltage:
1,8/3 kV
The halogen-free CC-rubber cable
NSHXAF-358 is particulary suited as a short
circuit-proof cable in rail and bus vehicles as well as
in dry rooms. Cables with a rated voltage of at least
1,8/3 kV are considered to be short circuit-proof and
short to earth-proof in switching equipment and
distributors up to 1000 V.
.

Construction

Bare or tinned fine strands of copper wire, core


insulation halogen-free polymere mixture. Outer
sheath halogen-free polymere mixture, oil resistant
and flame retardant (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour black.

382

Test voltage:
6000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
fixed installation:
flexible application:

Temperature range:
-25C to +100C
-5C to +100C

fixed installation:
flexible application:

Bending radius:
6 X cable diameter
10 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 606 (design)

ConCab kabel connects the world

Part-No.

Crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

7,0
7,5
9,0
9,5
11,0
13,0
15,0
16,5
18,0
20,5
24,0
26,0
28,0
31,0
34,5
38,0

47
49
77
97
153
214
324
421
564
758
995
1253
1540
1862
2428
3470

7,0
7,5
9,0
9,5
11,0
13,0
15,0
16,5
18,0
20,5
24,0
26,0
28,0
31,0
34,5
38,0

65
75
95
115
185
260
395
475
630
890
1190
1440
1765
2160
2725
3470

Cu-bare
358 0015 0
358 0025 0
358 0040 0
358 0060 0
358 0100 0
358 0160 0
358 0250 0
358 0350 0
358 0500 0
358 0700 0
358 0950 0
358 1200 0
358 1500 0
358 1850 0
358 2400 0
358 3000 0

1,5
2,5
4,0
6
10
16
25
35
50
70
95
120
150
185
240
300

14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0
480,0
672,0
912,0
1155,0
1440,0
1776,0
2305,0
2890,0
Cu-tinned

358 0015 1
358 0025 1
358 0040 1
358 0060 1
358 0100 1
358 0160 1
358 0250 1
358 0350 1
358 0500 1
358 0700 1
358 0950 1
358 1200 1
358 1500 1
358 1850 1
358 2400 1
358 3000 1

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0
480,0
672,0
912,0
1155,0
1440,0
1776,0
2305,0
2890,0

ConCab kabel connects the world

383

CC-welding cable
H01N2-D-355
H01N2-E-355
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 355 H01N2-E

Technical data
Rated voltage:
100/100 V
Test voltage:
1000 V
The CC-welding cable H01N2-D-355 resp.
H01N2-E-355 is used as a machine or manual
welding cable or even as a connection cable between
generator and an electrode. Its flexibility and
resistance to hard mechanical stress makes it suitable
for use in automotive-, tool and ship industry.
The cable can be used in dry or damp rooms as well
as outdoors.

Conductor standing:
H01N2-D:
fine copper strands
acc. to DIN VDE 0295, class 5
H01N2-E:
superfine copper strands
acc. to DIN VDE 0295, class 6

Construction

Temperature range:
-25C to +80C

Fine strands of bare copper wire with H01N2-D, resp.


superfine strands of bare copper wire with H01N2-E.
Outer sheath based on rubber with single or double
layer, flame retardant and self-extinguishing
(acc. to DIN VDE 0482-2-1, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.

384

Insulation resistance:
min. 10 MOhm X km

H01N2-D:
H01N2-E:

Bending radius:
12 X cable diameter
10 X cable diameter

Approvals:
acc. to DIN VDE 0282, part 6

ConCab kabel connects the world

Part-No.

Crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

H01N2-D
355 0100
355 0160
355 0250
355 0350
355 0500
355 0700
355 0950
355 1200
355 1500
355 1850

10
16
25
35
50
70
95
120
150
185

96,0
153,6
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0

7,7 - 9,7
8,8 - 11,0
10,1 - 12,7
11,4 - 14,2
13,2 - 16,5
15,3 - 19,2
17,4 - 21,4
19,2 - 24,0
21,1 - 26,4
23,1 - 28,9

140
216
300
415
571
801
1064
1323
1619
1966

6,2 - 7,8
7,3 - 9,1
8,6 - 10,8
9,8 - 12,3
11,9 - 14,8
13,6 - 17,0
15,6 - 19,5
17,2 - 21,6
18,8 - 23,5
20,4 - 25,5

125
195
295
403
541
786
1044
1289
1578
1867

H01N2-E
355 0100 1
355 0160 1
355 0250 1
355 0350 1
355 0500 1
355 0700 1
355 0950 1
355 1200 1
355 1500 1
355 1850 1

10
16
25
35
50
70
95
120
150
185

96,0
153,6
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0

ConCab kabel connects the world

385

CC-Hydro-N-722
Submersible rubber cable for use in waste water
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 722 3x2,5 Hydro-N

Technical data
Rated voltage:
450/750 V
Test voltage:
2500 V

The CC-Hydro-N-722 is suitable in waste water for


the link-up of electrical appliances such as for
pollution abatement facilities, submerged pumps and
scavenging collecting devices up to a diving depth of
500 m. The cable is also suitable for outdoor use as
well as in dry, damp or wet rooms. The cable may not
however be used in explosive endangered areas. It is
also used as a connection cable for rotary motors up
to 1000 V for protected and fixed installations.

Construction

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 100 MOhm X km
Temperature range:
In air:
fixed installation:
-45C to +70C
flexible application:
-25C to +70C
In water:
max. +40C
higher temperatures reduce the lifespan

Fine strands of bare copper wire, covered with a


plastic foil separation layer, rubber based insulation,
core colours acc. to DIN VDE 0293, part 308, cores
twisted in layers. Outer sheath on special rubber basis.
Colour black.

386

ConCab kabel connects the world

Bending radius:
12 X cable diameter
Approvals:
acc. to DIN VDE 0282

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

722 0010 03
722 0010 04

3 G 1,0
4 G 1,0

29,0
38,4

9,8
11,0

115
135

722 0015 03
723 0015 03
722 0015 04

3 G 1,5
3 X 1,5
4 G 1,5

43,0
witho.gnye
58,0

10,5
10,5
11,2

140
140
185

722 0025 03
723 0025 03
722 0025 04

3 G 2,5
3 X 2,5
4 G 2,5

72,0
witho.gnye
96,0

11,8
11,8
12,9

210
210
260

722 0040 03
723 0040 03
722 0040 04

3G4
3X4
4G4

115,0
witho.gnye
154,0

13,6
13,6
15,0

286
286
340

722 0060 01
722 0060 03
722 0060 04

1X6
3G6
4G6

58,0
173,0
230,0

8,7
15,0
16,5

120
370
450

722 0100 01
722 0100 03
722 0100 04

1 X 10
3 G 10
4 G 10

96,0
288,0
384,0

10,0
22,0
23,2

195
635
710

722 0160 01
722 0160 03
722 0160 04

1 X 16
3 G 16
4 G 16

154,0
461,0
614,0

11,8
25,8
27,8

285
945
1190

722 0250 01
722 0250 03
722 0250 04

1 X 25
3 G 25
4 G 25

240,0
720,0
960,0

13,7
30,9
33,1

401
1290
1680

722 0350 01
722 0350 03
722 0350 04

1 X 35
3 G 35
4 G 35

336,0
1008,0
1344,0

15,3
34,8
37,0

530
1720
2250

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg / km

722 0500 01
722 0500 03
722 0500 04

1 X 50
3 G 50
4 G 50

480,0
1440,0
1920,0

17,8
40,0
42,5

739
2480
3155

722 0700 01
722 0700 03
722 0700 04

1 X 70
3 G 70
4 G 70

672,0
2016,0
2688,0

20,0
45,0
47,8

990
3290
4180

722 0950 01
722 0950 03
722 0950 04

1 X 95
3 G 95
4 G 95

912,0
2736,0
3648,0

22,2
51,5
53,8

1290
4195
4590

ConCab kabel connects the world

387

CC-Hydro-T-724
Submersible rubber cable for use in drinking water
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 724 3x2,5 Hydro-T

Technical data
Rated voltage:
450/750 V

The CC-Hydro-T-724 is suitable for the


link-up of electrical appliances such as for pollution
abatement facilities, submerged pumps and float type
switches up to a diving depth of 500 m. Its suitability
for use in drinking water and meets the KTW
recommendations (polymer drinking water
recommendation of the polymer materials commisson
of the German Federal Health Office). The cable is
also suitable for outdoor use as well as in dry, damp
or wet rooms. The cable may not however be used in
explosive endangered areas. It is also used as a connection cable for rotary motors up to 1000 V for
protected and fixed installations.

Construction
Fine strands of bare copper wire, covered with a plastic foil separation layer, rubber based insulation, core
colours acc. to DIN VDE 0293, part 308, cores
twisted in layers. Outer sheath on special rubber basis.
Colour blue.

388

Test voltage:
2500 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 100 MOhm X km
Temperature range:
In air:
fixed installation:
-45C to +70C
flexible application:
-25C to +70C
In water:
max. +60C
higher temperatures reduce the lifespan
Bending radius:
12 X cable diameter
Approvals:
acc. to DIN VDE 0282, 0298-300

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

724 0015 003


725 0015 003
724 0015 004

3 G 1,5
3 X 1,5
4 G 1,5

43,0
witho.gnye
58,0

10,1
10,1
11,1

125
125
148

724 0025 003


725 0025 003
724 0025 004

3 G 2,5
3 X 2,5
4 G 2,5

72,0
witho.gnye
96,0

11,2
11,2
12,1

162
162
201

724 0040 003


725 0040 003
724 0040 004

3G4
3X4
4G4

115,0
witho.gnye
154,0

12,2
12,2
13,4

216
216
276

724 0060 001


725 0060 003
724 0060 004

1G6
3X6
4G6

58,0
173,0
230,0

8,0
13,7
15,2

103
292
378

724 0100 001


725 0100 003
724 0100 004

1 G 10
3 X 10
4 G 10

96,0
288,0
384,0

9,1
18,3
19,8

152
514
646

724 0160 001


725 0160 003
724 0160 004

1 G 16
3 X 16
4 G 16

154,0
461,0
614,0

10,1
21,1
22,9

212
740
934

724 0250 001


725 0250 003
724 0250 004

1 G 25
3 X 25
4 G 25

240,0
720,0
960,0

12,4
25,1
28,3

316
1094
1418

724 0350 001


725 0350 003
724 0350 004

1 G 35
3 X 35
4 G 35

336,0
1008,0
1344,0

13,9
28,3
31,3

422
1418
1877

724 0500 001


725 0500 003
724 0500 004

1 G 50
3 X 50
4 G 50

480,0
1440,0
1920,0

15,7
32,9
36,2

579
2018
2613

724 0700 001


725 0700 003
724 0700 004

1 G 70
3 X 70
4 G 70

672,0
2016,0
2688,0

18,3
38,4
41,7

808
2808
3638

724 0950 001


725 0950 003
724 0950 004

1 G 95
3 X 95
4 G 95

912,0
2736,0
3648,0

20,3
42,0
47,7

1026
3547
4643

Part-No. 725... without green/yellow earth conductor

ConCab kabel connects the world

389

CC-Hydro-T-flat-726
Submersible flat rubber cable for use in drinking water
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 726 3x4 Hydro-T-flach

Technical data
Rated voltage:
450/750 V
Test voltage:
2500 V
The CC-Hydro-T-flat-726 is suitable for the
link-up of electrical appliances such as for pollution
abatement facilities, submerged pumps and float type
switches up to a diving depth of 500 m. It is suitable
for use in drinking water and meets the KTW
recommendations (polymer drinking water
recommendation of the polymer materials commisson
of the German Federal Health Office). The cable may
not however be used in explosive endangered areas. It
is also used as a connection cable for rotary motors up
to 1000 V for protected and fixed installations.

Construction
Fine strands of bare copper wire, covered with a
plastic foil separation layer, rubber based insulation,
core colours acc. to DIN VDE 0293, part 308. Cores
layed parallel. Outer sheath on special rubber basis.
Colour blue (black on request).

390

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 100 MOhm X km
Temperature range:
In air:
fixed installation:
-45C to +70C
flexible application:
-25C to +70C
In water:
max. +60C
higher temperatures reduce the lifespan
Bending radius:
10 X cable thickness
Approvals:
acc. to DIN VDE 0282, 0298-300

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
Outside Weight
weight dimensions
kg/km

mm

kg /km

726 0015 03 1
727 0015 03 1
726 0015 04 1

3 G 1,5
3 X 1,5
4 G 1,5

43,0
witho.gnye
58,0

6,3 X 12,2
6,3 X 12,2
7,5 X 18,5

117
117
156

726 0025 03 1
727 0025 03 1
726 0025 04 1

3 G 2,5
3 X 2,5
4 G 2,5

72,0
witho.gnye
96,0

7,5 X 14,5
7,5 X 14,5
7,5 X 18,5

161
161
214

726 0040 03 1
727 0040 03 1
726 0040 04 1

3G4
3X4
4G4

115,0
witho.gnye
154,0

8,3 X 16,6
8,3 X 16,6
8,3 X 21,5

223
223
301

727 0060 03 1
726 0060 04 1

3X6
4G6

173,0
230,0

9,5 X 19,0
9,5 X 25,5

300
411

727 0100 03 1
726 0100 04 1

3 X 10
4 G 10

288,0
384,0

10,5 X 21,5
10,5 X 29,0

461
623

727 0160 03 1
726 0160 04 1

3 X 16
4 G 16

461,0
614,0

14,5 X 28,0
14,5 X 36,5

767
1044

727 0250 03 1
726 0250 04 1

3 X 25
4 G 25

720,0
960,0

17,0 X 34,0
17,0 X 44,5

1117
1514

727 0350 03 1
726 0350 04 1

3 X 35
4 G 35

1008,0
1344,0

19,0 X 40,0
20,0 X 53,0

1493
2102

727 0500 03 1
726 0500 04 1

3 X 50
4 G 50

1440,0
1920,0

21,5 X 45,5
22,0 X 60,5

2043
2840

727 0700 03 1
726 0700 04 1

3 X 70
4 G 70

2016,0
2688,0

24,0 X 53,0
25,0 X 69,5

2803
3896

727 0950 03 1
726 0950 04 1

3 X 95
4 G 95

2736,0
3648,0

26,0 X 56,5
27,0 X 74,7

3536
4867

Part-No. 727... without green/yellow earth conductor

ConCab kabel connects the world

391

392

CC-Lift-H-180
Lift cable with hemp support and braided fabric
Conforms to the EC low voltage guidelines 73/23/EEC

ConCab kabel Mainhardt 180 18G1,0 Lift-H

Technical data
Rated voltage:
300/500 V

The CC-Lift-H-180 was specially designed to be used


in lift, elevator constructions and in conveyor
installations. The additional textile braid covering the
cable assembly ensures flexing work during running
does not impinge on the cores so that the cores are
protected from exterior mechanical strains.

Test voltage:
3000 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:
min. 20 MOhm X km

Superfine strands of bare copper wire, PVC core


insulation, core colours black with white numbering
and green/yellow protective conductor on the outer
layer. Cores twisted in very short lay lengths around
the hemp element, textile tape wrapping, textile braid.
Outer sheath based on cold-flexible PVC, weather
resistant, flame retardant and self extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.
Part-No.

Temperature range:
-15C to +70C
Bending radius:
20 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0281

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

Suspension
length
approx.

kg/km

mm

kg/km

180 0007 012


180 0007 018
180 0007 024

12 G 0,75
18 G 0,75
24 G 0,75

86,0
130,0
173,0

18,0
18,4
20,8

370
465
520

120
120
80

180 0010 007


180 0010 012
180 0010 018
180 0010 020
180 0010 024
180 0010 036
180 2810 205

7 G 1,0
12 G 1,0
18 G 1,0
20 G 1,0
24 G 1,0
36 G 1,0
28 G 1,0 +
(2 x 0,5)CY

67,0
115,0
173,0
192,0
230,0
346,0
295,0

14,7
18,8
19,5
20,0
22,3
28,0
25,9

230
400
450
500
590
950
765

90
80
80
70
60
90
90

For installation instructions please see page 551

ConCab kabel connects the world

393

CC-Lift-S-186
Lift cable with steel supporting wire and braid
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 186 24 G 1,0 Lift-S

Technical data
Rated voltage:
300/500 V

The CC-Lift-S-186 is ideal for use in lift


constructions and conveying equipment with extreme
suspension lengths. The extra textil braid, covering
the core assembly, ensures flexing work during
running does not impinge on the cores so that the
cores are protected from mechanical strains.

Test voltage:
3000 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6

Construction

Insulation resistance:
min. 20 MOhm X km

Superfine strands of bare copper wire, PVC core


insulation, core colours black with white numbering
and green/yellow protective conductor in the outer
layer. Cores twisted in very short lay lengths around
the steel support, textile tape wrapping, textile braid.
Outer sheath based on cold-flexible PVC, weather
resistant, flame retardant and self-extinguishing (acc.
to DIN VDE 0482, part 265-2-1 resp.EN 50265-2-1
and IEC 60332-1).
Colour black.
Part-No.

186 0010 024


186 0010 036

Temperature range:
-15C to +70C
Bending radius:
20 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0281

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

Suspension
length
approx.

kg/km

mm

kg/km

24 G 1,0
36 G 1,0

230,0
346,0

23,0
29,0

610
965

150
150

For installation instruction please see page 551.

394

ConCab kabel connects the world

CC-Lift-2S-187
Lift cable with two supporting steel wires
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 187 18G1,5 Lift-2S

Technical data

The CC-Lift-2S-187 is particularly used as lift and


hoist control cable in manual control units and
conveyor systems. The two exterior steel wires
support make it ideal for use on control platforms
where self-supporting cables are needed, e.g., with
high-lift storage shelving. The weather resistant outer
sheath makes it excellent for use under extreme
operation and temperature conditions.

Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6

Construction
Superfine strands of bare copper wire, PVC core
insulation, core colours are black with white
numbering and green/yellow protective conductor in
the outer layer, cores twisted in very short lay lengths,
textile tape wrapping. Outer sheath based on
cold-flexible PVC, weather resistant, flame retardant
and self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
The two supporting steel wires
(tear resistance per rope approx. 2000 N) are
integrated in the outer sheath and are seperable
without damaging the outer sheath. Colour black.
Part-No.

No. of
cores
+
crosssection

Copper- Dimensions Weight


weight
approx.
kg/km

mm

kg/km

187 0010 010


187 0010 012
187 0010 018
187 0010 025
187 0010 030

10 X 1,0
12 G 1,0
18 G 1,0
25 G 1,0
30 G 1,0

96,0
115,0
173,0
240,0
288,0

15,0 x 27,1
15,0 x 27,1
17,2 x 32,1
21,1 x 36,0
22,0 x 39,2

416
450
530
660
765

187 0015 008


187 0015 012
187 0015 016

8 G 1,5
12 G 1,5
16 G 1,5

115,0
173,0
230,0

15,0 x 27.2
16,6 x 31,6
18,7 x 32,2

435
510
594

Insulation resistance:
min. 20 MOhm X km
Temperature range:
-15C to +70C
Bending radius:
20 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0281
Part-No.

187 0015 018


187 0015 020
187 0015 024

No. of
cores
+
crosssection
18 G 1,5
20 G 1,5
24 G 1,5

ConCab kabel connects the world

Copper- Dimensions Weight


weight
approx.
kg/km

mm

kg/km

260,0
288,0
346,0

19,2 x 32,0
20,9 x 36,0
22,5 x 37,0

678
798
900

395

C-flat cable H05VVH6-F-118


H07VVH6-F-118
Cold-flexible flat cable for cranes and conveyors
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 118 8G1,5 H07VVH6-F

Technical data
up to 1,0mm2:
from 1,5mm2:
The harmonized CC-flat cable-118 is suitable indoors
as a control and link-up cable for crane and conveyor
systems as well as for moving machine parts. In
comparison to round cables these closely laid cores
achieve a considerable smaller bending radius.
The CC-flat cable can be installed in dry and damp
rooms. The cold-flexible PVC outer sheath enables it
to be even used at low temperatures. The cable is also
suitable to be installed in lifts and hoists as long as the
suspension length does not exceed 35 m and the
travelling speed does not exceed 1,6 m/s. The outer
sheath is extensively resistant to oil, fat, acid and lye.

Construction
Fine strands of bare copper wire, PVC core insulation,
core colours acc. to DIN VDE 0293, part 308, 6 cores
or more with green/yellow protective conductor in the
middle. Outer sheath out of cold-flexible PVC, flame
retardant (acc. to DIN VDE 0482, part 265-2-1
resp.EN 50265-2-1 and IEC 60332-1).
Colour black.

396

Rated voltage:
300/500 V
450/750 V
Test voltage:
3000 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-30C to + 70C
-5C to + 70C

Bending radius:
Flexible application
up to 8 mm thickness: 5 X cable thickness
up to 12 mm thickness: 8 X cable thickness
above 12 mm thickness: 10 X cable thickness

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0281,
part 403 and part 404

Part-No.

No. of
cores
+
crosssection

Copper
weight
kg/km

Dimensions Weight
approx.
mm

kg/km

118 0007 004


118 0007 008
118 0007 012
118 0007 018
118 0007 024

4 G 0,75
8 G 0,75
12 G 0,75
18 G 0,75
24 G 0,75

29,0
58,0
86,0
130,0
172,8

4,2 x 12,6
4,2 x 23,2
4,2 x 33,8
4,2 x 50,2
4,2 x 65,6

90
175
260
380
490

118 0010 004


118 0010 005
118 0010 008
118 0010 012
118 0010 018
118 0010 024

4 G 1,0
5 G 1,0
8 G 1,0
12 G 1,0
18 G 1,0
24 G 1,0

38,4
48,0
77,0
115,0
173,0
230,4

4,4 x 13,4
4,4 x 15,5
4,4 x 24,8
4,4 x 36,2
4,4 x 53,8
4,4 x 70,4

105
120
205
300
450
590

118 0015 004


118 0015 005
118 0015 007
118 0015 008
118 0015 010
118 0015 012
118 0015 018
118 0015 024

4 G 1,5
5 G 1,5
7 G 1,5
8 G 1,5
10 G 1,5
12 G 1,5
18 G 1,5
24 G 1,5

58,0
72,0
101,0
115,0
144,0
173,0
259,0
346,0

5,1 x 14,8
5,1 x 17,7
5,1 x 25,2
5,1 x 27,2
5,1 x 34,0
5,1 x 40,5
5,1 x 61,4
5,1 x 83,0

167
187
217
267
312
393
665
786

118 0025 004


118 0025 005
118 0025 007
118 0025 008
118 0025 010
118 0025 012
118 0025 024

4 G 2,5
5 G 2,5
7 G 2,5
8 G 2,5
10 G 2,5
12 G 2,5
24 G 2,5

96,0
120,0
168,0
192,0
240,0
288,0
605,0

5,8 x 18,0
5,8 x 21,5
5,8 x 31,7
5,8 x 33,7
5,8 x 42,6
5,8 x 49,5
5,8 x 102,0

202
260
345
389
490
580
1160

118 0040 004


118 0040 005
118 0040 007

4G4
5G4
7G4

154,0
192,0
269,0

7,0 x 21,1
7,0 x 26,0
7,0 x 35,5

311
397
539

118 0060 004


118 0060 005
118 0060 007

4G6
5G6
7G6

230,0
288,0
403,0

8,0 x 22,4
8,0 x 31,4
8,0 x 42,8

432
550
755

118 0100 004


118 0100 005

4 G 10
5 G 10

384,0
480,0

9,6 x 28,7
9,6 x 37,5

712
1120

118 0160 004


118 0160 005

4 G 16
5 G 16

614,0
768,0

11,0 x 34,8
11,0 x 43,5

961
1280

118 0250 004

4 G 25

960,0

13,3 x 42,5

1484

118 0350 004

4 G 35

1344,0

14,5 x 49,6

1988

118 0500 004

4 G 50

1920,0

17,5 x 58,4

2880

118 0700 004

4 G 70

2688,0

20,0 x 63,0

3847

397

CC-flat cable PVC-CY-192


Cold flexible flat cable for cranes and conveyors, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 192 7x3x1,0 CY

The CC-flat cable PVC-CY-192 shielded


is suitable indoors as a control and signal cable for
cranes and conveyors as well as for moving machine
parts. The copper shielded single or respectively bundled cores make this cable ideally suited for use where
considerable demands on electromagnetic
compatibiliy (EMC) are made. The closely packed
shielded cores or bundles enable it to achieve a much
smaller bending radius in comparison to round cables.
The CC-flat cable PVC-CY can be installed in dry
and damp rooms. The outer sheath is extensively
resistant to oil, fat acid and lye.

Technical data
Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 5 or 6

Construction
Fine strands of bare copper wire, PVC core insulation,
cores acc. to DIN VDE 0293 part 308, to 6 cores are
black with consecutive white numbering and
green/yellow protective conductor. Cores resp.
bundles shielded with tinned copper shield bandage
underneath and above the shield. Other sheath out of
cold-flexible PVC, flame retardant (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Colour black.

398

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

ConCab kabel connects the world

Temperature range:
-30C to +70C
-5C to +70C
Bending radius:
20 X cable thickness

Approvals:
acc. to DIN VDE 0250, 0281

Part-No.

No. of cores
+
crosssection

Copper
weight

Dimensions
approx.

Weight

kg/km

mm

kg/km

192 505 01
5 G (0,50)
192 5405 00
5 X (4 X 0,50)*
192 7405 00
7 X (4 X 0,50)*
192 8705 01
8 G (7 X 0,50)
192 14405 00 14 X (4 X 0,50)*

61,4
133,0
222,0
455,0
444,0

3,4 X 21,0
7,2 X 37,4
10,3 X 50,0
11,7 X 68,6
10,3 X 100,0

150
440
750
1180
1490

192 410 00
192 4410 01
192 7310 01
192 14310 01

4 X (1,0)*
4 G (4 X 1,0)
7 G (3 X 1,0)
14 G (3 X 1,0)

57,5
315,0
275,0
551,0

5,0 X 13,9
11,0 X 33,5
10,3 X 50,0
10,3 X 100,0

130
630
760
1510

192 415 00
192 815 01
192 815 00
192 1215 00

4 X (1,5)*
8 G (1,5)
8 X (1,5)*
12 X (1,5)*

114,0
220,0
220,0
335,0

5,8 X 18,8
5,8 X 35,5
5,8 X 35,5
6,0 X 50,0

210
400
400
610

192 425 01

4 G (2,5)

168,0

6,9 X 21,0

270

192 440 01

4 G (4,0)

222,0

7,6 X 24,4

400

192 460 01

4 G (6,0)

325,0

9,1 X 29,4

520

192 4100 01

4 G (10,0)

522,0

10,5 X 35,8

840

192 4160 01

4 G (16,0)

784,0

12,5 X 41,2

1.243

192 4250 01

4 G (25,0) 1.163,0

14,4 X 48,2

1.762

*without gnye protective conductor

ConCab kabel connects the world

399

CC-flat cable neoprene-731


Robust und weather resistant flat cable for cranes and conveyors
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 731 8G1,5 Neoprene

Technical data
Rated voltage:
300/500 V
The CC-flat cable neoprene-731 is suitable as a
control and connection cable for cranes and conveyors
on building sites, container goods railway stations and
dockyards where operating conditions are rough.
The closely packed cores lying side by side achieve a
much tighter bending radius in comparison to round
cables. The robust outer sheath is extensively
resistant to oil, fat, acid and lye.

Test voltage:
3000 V
Conductor stranding:
up to 25 mm2 :
superfine copper strands
acc. to DIN VDE 0295, class 6
from 35 mm2:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 10 MOhm X km

Construction
Fine strands of bare or tinned copper wire, rubber
based core insulation, core colours acc. to DIN VDE
0293, part 308, 6 cores or more black with white
numbering and green/yellow protective conductor in
the middle. Outer sheath special polychloreprene basis
(neoprene), cold-flexible, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour black.

400

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-25C to +80C
Bending radius:
10 X cable thickness

Approvals:
acc. to DIN VDE 0250, part 809

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Dimensions Weight
approx.

kg/km

mm

kg/km

731 0015 004


731 0015 005
731 0015 007
731 0015 008
731 0015 010
731 0015 012
731 0015 024

4 G 1,5
5 G 1,5
7 G 1,5
8 G 1,5
10 G 1,5
12 G 1,5
24 G 1,5

58,0
72,0
101,0
115,0
144,0
173,0
346,0

5,8 X 16,8
5,8 X 21,4
5,8 X 27,8
5,8 X 30,9
6,4 X 39,1
6,4 X 45,7
12,0 X 54,0

175
211
285
324
448
525
1070

731 0025 004


731 0025 005
731 0025 007
731 0025 008
731 0025 010
731 0025 012
731 0025 024

4 G 2,5
5 G 2,5
7 G 2,5
8 G 2,5
10 G 2,5
12 G 2,5
24 G 2,5

96,0
120,0
168,0
192,0
240,0
288,0
578,0

7,0 X 19,6
7,0 X 25,2
7,0 X 32,9
7,0 X 36,6
7,6 X 46,9
7,6 X 54,3
16,2 X 68,5

263
337
461
490
565
776
1827

731 0040 004


731 0040 005
731 0040 007

4G4
5G4
7G4

154,0
192,0
269,0

8,5 X 23,5
8,5 X 29,9
8,5 X 38,7

375
529
642

731 0060 004


731 0060 005
731 0060 007

4G6
5G6
7G6

230,0
288,0
403,0

9,3 X 26,9
9,3 X 33,7
9,3 X 44,5

511
740
879

731 0100 004


731 0100 005
731 0100 007

4 G 10
5 G 10
7 G 10

384,0
480,0
672,0

10,6 X 32,3
10,6 X 40,4
10,6 X 54,0

748
946
1345

731 0160 004


731 0160 005
731 0160 007

4 G 16
5 G 16
7 G 16

614,0
768,0
1075,0

12,4 X 37,0
12,4 X 50,0
12,4 X 65,1

1157
1450
2291

731 0250 004


731 0250 005
731 0250 007

4 G 25
5 G 25
7 G 25

960,0
1200,0
1680,0

14,0 X 44,6
15,2 X 59,6
15,2 X 77,8

1714
2228
3162

731 0350 004

4 G 35

1344,0

16,5 X 52,9

2152

731 0500 004

4 G 50

1920,0

19,1 X 61,0

2996

731 0700 004

4 G 70

2688,0

21,6 X 70,4

4300

731 0950 004

4 G 95

3648,0

24,4 X 78,9

5730

731 1200 004

4 G 120

4608,0

26,0 X 87,6

6300

ConCab kabel connects the world

401

CC-flat cable neoprene-C5G-735


Robust and weather resistant flat cable
for cranes and conveyors, shielded
Conforms to the EC low voltage guideline 73/23/EE

ConCab kabel Mainhardt 735 8G1,5 Neoprene-C5G

The CC-flat cable neoprene-C5G-735 shielded


is a suitable control and connection cable for cranes
and conveyors especially on building sites, container
goods railway stations and dockyards where operating
conditions are rough. The copper shielded single or
respectively bundled cores make this cable ideally
suited for use where considerable demands for
electromagnetic compatibiliy (EMC) are made. The
closely packed cores lying side by side achieve a
much tighter bending radius in comparison to round
cables. The robust outer sheath is extensively resistant
to oil, fat, acid and lye.

Construction
Fine strands of bare or tinned copper wire, rubber
based core insulation, core colours acc. to DIN VDE
0293, part 308, 3 cores or more with green/yellow
protective conductor in the middle, cores shielded
with tinned copper braid, bandage underneath and
above the braiding. Outer sheath of special
polychloreprene (neoprene), cold-flexible, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp. EN
50265-2-1 and IEC 60332-1).
Colour black.

402

Technical data
Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
up to 25 mm2 :
superfine copper strands
acc. to DIN VDE 0295, class 6
from 35 mm2:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-25C to +80C
Bending radius:
10 X cable thickness

Approvals:
acc. to DIN VDE 0250, part 809

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper Dimensions
weight
approx.

Weight

kg/km

mm

kg/km

735 0015 004


735 0015 008
735 0015 012

4 G 1,5
8 G 1,5
12 G 1,5

79,0
228,0
342,0

8,0 X 22,6
8,0 X 41,1
8,0 X 59,8

361
540
800

735 0025 004


735 0025 006
735 0025 012

4 G 2,5
6 G 2,5
12 G 2,5

163,0
245,0
493,0

8,6 X 24,2
8,6 X 33,8
8,6 X 65,1

420
540
1010

735 0040 004

4G4

244,0

9,1 X 26,3

500

735 0060 004

4G6

321,0

9,8 X 29,1

610

735 0100 004

4 G 10

497,0

11,7 X 35,4

960

735 0160 004

4 G 16

805,0

14,0 X 40,8

1324

735 0250 004

4 G 25

1141,0

16,0 X 51,0

1800

735 0350 004

4 G 35

1633,0

18,0 X 60,0

2500

735 0500 004

4 G 50

2261,0

20,5 X 67,0

3300

ConCab kabel connects the world

403

CC-crane cable NSHTU-732


Flexible drum-reeling cable
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 732 18G2,5 NSHTU

Technical data
The CC-crane cable NSHTU-732 is suitable where
heavy mechanical tasks such as frequent winding and
unwinding with torsional strain at the same time are.
This occurs especially in transport and conveyor systems, hoists, mining and railtrack motors. The neoprene outer sheath makes the cable resistant to ozone
and UV radiation as well as to oil, acid, fat and solvents. The cable may be used in dry, damp and wet
rooms as well as outdoors.

Rated voltage:
0,6/1 kV
Test voltage:
2500 V
Conductor stranding:
fine tinned copper strands
acc. to DIN VDE 0295, class 5

Construction
Fine strands of tinned copper wire, rubber based core
insulation, core colours acc. to DIN VDE 0293,
part 308, 6 cores or more black with white numbering
and green/yellow protective conductor in the outer
layer, cores twisted in short lay lengths, outer sheath
based on neoprene (5GM2) with vulcanized textile
braiding as torsion protection. The outer sheath is
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.

404

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-45C to +80C
-25C to +80C

diameter up to 20 mm:
diameter above 20 mm:

Bending radius:
5 X cable diameter
6 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 814

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

732 0015 003


732 0015 004
732 0015 005
732 0015 007
732 0015 012
732 0015 018
732 0015 024
732 0015 030
732 0015 042

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
24 G 1,5
30 G 1,5
42 G 1,5

58,0
81,0
115,0
196,0
271,0
392,0
432,0
633,0

13,6
14,6
15,6
18,4
21,8
25,0
28,8
30,9
35,2

190
218
262
380
715
768
995
1229
1733

732 0025 003


732 0025 004
732 0025 005
732 0025 007
732 0025 012
732 0025 018
732 0025 024
732 0025 030
732 0025 040
732 0025 050

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
18 G 2,5
24 G 2,5
30 G 2,5
40 G 2,5
50 G 2,5

75,0
99,0
124,0
180,0
308,0
451,0
616,0
771,0
1212,0
1300,0

15,2
16,7
18,5
21,0
24,9
29,2
33,5
35,0
40,8
48,5

308
368
427
578
828
1195
1565
1860
3115
4400

732 0040 004


732 0040 005

4G4
5G4

158,0
225,0

19,7
22,0

552
615

732 0060 004


732 0060 005

4G6
5G6

241,0
317,0

21,6
23,8

591
753

732 0100 004


732 0100 005

4 G 10
5 G 10

404,0
510,0

25,8
28,1

974
1189

732 0160 004


732 0160 005

4 G 16
5 G 16

642,0
844,0

25,1
30,8

1388
1667

732 0250 004

4 G 25

1005,0

35,0

2027

732 0350 004

4 G 35

1410,0

38,8

2569

732 0500 004

4 G 50

2010,0

44,8

3590

732 0700 004

4 G 70

2688,0

50,2

4637

732 0950 004

4 G 90

3648,0

58,5

6468

732 1200 004

4 G 120

4857,0

63,5

7870

732 1500 004

4 G 150

6011,0

67,9

9707

For installation instruction please see page 550.

ConCab kabel connects the world

405

CC-crane cable PUR-190


Halogen-free, drum reeling cable with strain relief
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 190 18G1,0 PUR

The CC-crane cable PUR-190 is suitable to be used in


crane facilities in dockyards and on railways as well
as in road and mining industries. The exceptionally
robust and abrasion resistant outer sheath as well as
the optimized twisted lay lengths, enable this cable to
be used in drag chains, control platforms, pumps and
in similar appliances. The cable is resistant to ozone
and UV radiation, oil, fat and gasoline. It can be used
in waste water as well as in salt water.

Construction

Technical data
Rated voltage:
0,6/1 kV
Test voltage:
2500 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6

Superfine strands of bare copper wire, PUR core


insulation, core colours acc. to DIN VDE 0293, part
308, 6 cores or more black with white numbering
and a green/yellow protective conductor in the outer
layer, cores twisted in very short lay lengths around
the strain relief core, fleece wrapping, kevlar braid.
Outer sheath based on PUR, halogen-free, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour orange.

406

ConCab kabel connects the world

Insulation resistance:
min. 20 MOhm X km
Temperature range:
-40C to +80C
short-term: +100C
Bending radius:
10 X cable diameter
Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

Tensile
strength
approx.

kg/km

mm

kg/km

190 0010 008


190 0010 012
190 0010 018

8 G 1,0
12 G 1,0
18 G 1,0

77,0
115,0
173,0

14,0
17,6
22,8

200
300
475

2500
5000
5000

190 0015 003


190 0015 004
190 0015 005
190 0015 007
190 0015 008
190 0015 012

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
8 G 1,5
12 G 1,5

43,0
58,0
72,0
101,0
115,0
173,0

9,6
10,8
12,2
15,3
15,3
21,2

105
165
220
275
290
460

2000
2000
2000
2500
2500
7500

190 0025 005


190 0025 007

5 G 2,5
7 G 2,5

120,0
168,0

15,0
17,6

275
365

2500
3000

190 0040 004


190 0040 007

4G4
7G4

154,0
269,0

16,3
21,2

425
610

5000
5000

190 0060 004


190 0060 007

4G6
7G6

230,0
403,0

19,6
23,7

555
840

5000
5000

190 0100 004

4 G 10

384,0

22,8

680

5000

190 0160 004

4 G 16

614,0

25,0

1140

5000

190 0250 004

4 G 25

1029,0

29,0

1620

5000

190 0350 004

4 G 35

1344,0

36,4

2040

7500

190 0500 004

4 G 50

1920,0

42,0

2820

7500

For installation instruction please see page 550

ConCab kabel connects the world

407

CC-crane cable NSHTUK-Z-742


Flexible drum reeling cable with strain relief
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 742 4G4 NSHTUK-Z

Technical data
The CC-crane cable NSHTUK-Z-742 is suitable
where heavy mechanical tasks such as frequent
winding and unwinding with torsional strain are. This
occurs especially in transport, conveyor and hoist
systems. The neoprene outer sheath makes the cable
resistant to ozone and UV radiation as well as to oil,
acid, fat and solvents. The cable may be used in dry,
damp and wet rooms as well as outdoors.

Rated voltage:
0,6/1 kV
Test voltage:
2500 V
Conductor stranding:
fine tinned copper strands
acc. to DIN VDE 0295, class 5

Construction
Fine strands of tinned copper wire, rubber based core
insulation, core colours acc. to DIN VDE 0293, part
308, 6 cores or more black with white numbering and
a green/yellow protective conductor in the outer layer,
cores twisted in short lay lengths around the strain
relief core, outer sheath based on neoprene (5GM2)
with a vulcanized textile braiding as torsion
protection. The outer sheath is flame retardant and
self-extinguishing (acc. to DIN VDE 0482, part 2652-1 resp.EN 50265-2-1 and IEC 60332-1).
Colour yellow.

408

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-45C to +70C
-25C to +70C

diameter up to 20 mm:
diameter above 20 mm:

Bending radius:
5 X cable diameter
6 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 814

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

742 0015 007


742 0015 012
742 0015 018
742 0015 024
742 0015 026
742 0015 036

7 G 1,5
12 G 1,5
18 G 1,5
24 G 1,5
26 G 1,5
36 G 1,5

115,0
196,0
271,0
392,0
425,0
588,0

20,2
26,0
27,2
31,0
33,0
36,2

580
960
1045
1315
1335
1760

742 0025 007


742 0025 012

7 G 2,5
12 G 2,5

180,0
308,0

23,0
30,8

760
1280

742 0040 004


742 0040 005

4G4
5G4

161,0
225,0

20,0
22,5

660
770

742 0100 004


742 0100 005

4 G 10
5 G 10

404,0
515,0

27,5
30,0

1140
1310

742 0160 004


742 0160 005

4 G 16
5 G 16

642,0
768,0

31,2
34,5

1580
1860

742 0250 004

4 G 25

1005,0

36,0

2185

742 0500 004

4 G 50

2010,0

47,0

3845

742 0700 004

4 G 70

2688,0

52,0

4885

742 0950 004

4 G 95

3648,0

59,4

6450

For installation instruction please see page 550.

ConCab kabel connects the world

409

CC-control cable Neorund-733


Control cable robust and weather resistant with strain relief
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 733 18G1,5 Neorund

Technical data
The CC-control cable Neorund-733 is suitable as a
control and link-up cable in rough and weather-proof
conditions. It is specially designed for use in conveyor
and hoist systems, building machines, dockyards and
in container railway terminals. The integrated strain
relief core permits larger suspension lengths which
can sustain up additional tensile strength. This cable
can be used in water for industrial purposes, in sea
water and outdoors. The sheath is extensively resistant
to oil, fat, acid and lye.

Rated voltage:
300/500 V
Test voltage:
3000 V
Conductor stranding:
superfine copper strands
acc. to DIN VDE 0295, class 6
Insulation resistance:
min. 20 MOhm X km

Construction
Superfine strands of bare copper wire, rubber based
core insulation, core colours acc. to DIN VDE 0293,
part 308, 6 cores or more black with white
numbering, 3 cores or more with a green/yellow
protective conductor in the outer layer, cores twisted
in short lay lengths around the support core. Bandage
over each layer. Outer sheath on rubber basis, flame
retardant and self-extinguishing (acc. to DIN VDE
0482, part 265-2-1, resp. EN 50265-2-1 and IEC
60332-1). Colour black.

410

fixed installation:
flexible application:

Temperature range:
-40C to +80C
-25C to +80C

fixed installation:
flexible application:

Bending radius:
without restraint
5 X cable diameter
10 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

No. of
cores
+
crosssection

Copper Outer
weight diameter
approx.

Weight

Tensile
strength
approx.

kg/km

kg/km

mm

733 0010 002


733 0010 003
733 0010 004
733 0010 005
733 0010 007
733 0010 009
733 0010 012
733 0010 016
733 0010 018
733 0010 020
733 0010 024
733 0010 036
733 0010 048
733 0010 054
733 0010 061

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0
9 G 1,0
12 G 1,0
16 G 1,0
18 G 1,0
20 G 1,0
24 G 1,0
36 G 1,0
48 G 1,0
54 G 1,0
61 G 1,0

19,2
29,0
38,4
48,0
67,0
86,4
115,0
165,0
173,0
206,0
230,4
371,0
461,0
518,0
586,0

8,0
8,7
8,9
10,4
13,0
13,6
17,0
17,8
18,7
20,0
22,5
25,5
29,6
31,6
32,9

91
116
142
171
230
268
390
430
475
510
650
940
1247
1410
1496

300
150
300
1300
2300
2900
6700
570
960
980
2900
960
1440
1620
1830

733 0015 002


733 0015 003
733 0015 004
733 0015 005
733 0015 007
733 0015 008
733 0015 009
733 0015 010
733 0015 012
733 0015 015
733 0015 018
733 0015 019
733 0015 024
733 0015 037
733 0015 042
733 0015 048
733 0015 050
733 0015 061

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
8 G 1,5
9 G 1,5
10 G 1,5
12 G 1,5
15 G 1,5
18 G 1,5
19 G 1,5
24 G 1,5
37 G 1,5
42 G 1,5
48 G 1,5
50 G 1,5
61 G 1,5

29,0
44,0
58,0
72,0
102,0
115,0
130,0
153,0
173,0
229,0
259,0
274,0
346,0
533,0
642,0
691,0
720,0
880,0

8,0
9,5
10,5
11,8
13,8
14,0
15,8
17,0
20,5
22,5
23,6
24,1
26,0
31,0
33,5
35,0
37,0
42,1

96
130
180
237
294
310
335
406
520
590
630
670
818
1220
1389
1630
1740
1953

300
150
570
870
2600
3400
3900
450
7700
680
960
860
3800
960
1800
1600
1600
2000

733 0025 002


733 0025 003
733 0025 004
733 0025 005
733 0025 007
733 0025 009
733 0025 012
733 0025 016

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
9 G 2,5
12 G 2,5
16 G 2,5

48,0
72,0
96,0
120,0
168,0
216,0
288,0
411,0

9,7
10,2
12,3
12,4
15,8
18,9
24,0
24,3

143
173
256
309
380
542
710
815

300
300
570
570
3460
680
6000
570

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

Tensile
strength
approx.

kg/km

mm

kg / km

733 0025 018


733 0025 024
733 0025 036

18 G 2,5
24 G 2,5
36 G 2,5

432,0
576,0
864,0

26,4
28,5
33,2

1025
1402
2334

570
6100
2700

733 0040 004


733 0040 005

4G4
5G4

154,0
192,0

15,2
16,8

410
435

600
600

733 0060 004


733 0060 005

4G6
5G6

230,0
295,0

18,8
19,2

524
570

1000
1000

733 0100 004


733 0100 005

4 G 10
5 G 10

384,0
480,0

21,8
24,6

725
924

1200
1200

733 0160 004


733 0160 005

4 G 16
5 G 16

614,0
768,0

25,4
28,0

1057
1260

1900
2400

ConCab kabel connects the world

411

CC-rubber cable NSSHU-750


Rubber cable for high mechanical stress 0,6/1kV
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 750 12G2,5 NSSHU

Technical data
Rated voltage:
0,6/1 kV
The CC-rubber cable NSSHU-750 is designed for
strong mechanical tasks, e.g., coal mining underground, in open pit mining, on building sites and other
industries, in dry and damp rooms as well as outdoors.
It is also designed for fixed installation,
e.g., on plaster.

Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5

Construction
Fine strands of tinned copper wire, rubber based core
insulation, core colours acc. to DIN VDE 0293 part
308, 6 cores or more black with white numbering,
resp. cores white with black numbering, and
green/yellow protective conductor in the outer layer,
cores twisted in layers. Multi-core cable with inner
sheath based on rubber. Outer sheath based on
rubber (neoprene), flame retardant and
self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and
IEC 60332-1. Colour yellow.

412

Insulation resistance:
min. 20 MOhm X km
fixed installation:
flexible application:

Temperature range:
-40C to +80C
-25C to +80C

Bending radius:
fixed installation: 5 X cable diameter
flexible application: 10 X cable diameter
Approvals:
acc. to DIN VDE 0250, part 812

ConCab kabel connects the world

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg /km

mm

kg/km

750 0015 003


750 0015 004
750 0015 005
750 0015 007
750 0015 010

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
10 G 1,5

43,0
58,0
72,0
101,0
144,0

13,0
13,5
14,5
17,0
19,7

205
240
290
460
555

750 0025 002


750 0025 003
750 0025 004
750 0025 005
750 0025 007
750 0025 012
750 0025 018

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5
18 G 2,5

48,0
72,0
96,0
120,0
168,0
288,0
432,0

13,4
14,3
16,1
17,2
19,2
25,0
29,8

235
260
375
385
490
795
1230

750 0040 003


750 0040 004
750 0040 005

3G4
4G4
5G4

115,2
154,0
192,0

17,0
18,0
19,4

410
457
560

750 0060 003


750 0060 004
750 0060 005

3G6
4G6
5G6

173,0
230,0
288,0

18,1
20,3
23,0

509
560
675

750 0100 004


750 0100 005

4 G 10
5 G 10

384,0
480,0

25,0
26,5

860
1100

750 0160 001


750 0160 004
750 0160 005

1 X 16
4 G 16
5 G 16

154,0
614,0
768,0

11,8
30,3
31,5

260
1395
1500

750 0250 001


750 0250 004
750 0250 005

1 X 25
4 G 25
5 G 25

240,0
960,0
1200,0

14,9
35,1
36,1

390
2050
2930

750 0350 001


750 0350 004

1 X 35
4 G 35

336,0
1344,0

16,0
38,8

515
2580

Part-No.

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/ km

750 0500 001


750 0500 003
750 0500 004

1 X 50
3 G 50/25
4 G 50

480,0
1680,0
1920,0

18,3
44,9
45,1

695
3190
3710

750 0700 001


750 0700 003
750 0700 004

1 X 70
3 G 70/35
4 G 70

672,0
2352,0
2688,0

20,4
48,7
46,9

930
3870
4310

750 0950 001


750 0950 003
750 0950 004

1 X 95
3 G 95/50
4 G 95

912,0
3216,0
3648,0

22,7
50,6
56,8

1215
5710
6150

750 1200 001


750 1200 003
750 1200 004

1 X 120
3 G 120/70
4 G 120

1152,0
4128,0
4608,0

25,0
54,0
59,5

1515
6950
7205

750 1500 001

1 X 150

1440,0

27,5

1790

750 1850 001

1 X 185

1776,0

29,0

2280

750 2400 001

1 X 240

2304,0

34,2

2940

750 3000 001

1 X 300

2880,0

37,8

3450

Additional designs acc. to VDE 0250, part 812 on request

ConCab kabel connects the world

413

414

415

CC-Therm 105C-600
Heat-resistant PVC-control cable
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 600 3G1,5 105C

Technical data
Rated voltage:
300/500 V
Test voltage:
2000 V
The CC-Therm 105C-600 is suitable as a
control cable for environmental conditions involving
high temperatures. It can be used in machine tools,
plant and apparatus construction, heating,
air-conditioning and ventilation technology as well as
in additional sectors of electronic equipment.

Construction
Fine strands of bare copper wire, PVC heat-resistant
core insulation, core colours acc. to DIN VDE 0293,
part 308, cores twisted in layers. Outer sheath based
on heat-resistant PVC, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour black.

416

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
fixed installation:
short-term:

Temperature range:
-10C to + 90C
+105C

fixed installation:

Bending radius:
5 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

600 0005 002 3


600 0005 003 3
600 0005 004 3
600 0005 005 3
600 0005 007 3
600 0005 012 3
600 0005 018 3
600 0005 025 3

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5
7 G 0,5
12 G 0,5
18 G 0,5
25 G 0,5

9,6
14,4
19,2
24,0
33,6
58,0
86,0
101,0

5,1
5,3
5,7
6,8
8,2
10,2
11,7
14,9

40
52
64
69
90
145
172
248

600 0007 002 3


600 0007 003 3
600 0007 004 3
600 0007 005 3
600 0007 007 3
600 0007 012 3
600 0007 018 3
600 0007 025 3

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75
12 G 0,75
18 G 0,75
25 G 0,75

14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0

5,9
6,2
6,8
7,9
9,0
11,5
13,6
16,8

52
63
77
95
114
181
272
383

600 0010 002 3


600 0010 003 3
600 0010 004 3
600 0010 005 3
600 0010 006 3
600 0010 007 3
600 0010 012 3
600 0010 018 3
600 0010 025 3

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
6 G 1,0
7 G 1,0
12 G 1,0
18 G 1,0
25 G 1,0

19,2
29,0
38,0
48,0
58,0
67,0
115,0
173,0
240,0

6,4
6,9
7,9
8,7
9,3
10,0
12,6
14,9
18,2

62
75
89
110
122
131
224
352
487

600 0015 002 3


600 0015 003 3
600 0015 004 3
600 0015 005 3
600 0015 007 3
600 0015 012 3
600 0015 018 3
600 0015 025 3

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

7,5
8,2
9,2
10,2
11,7
14,6
17,5
21,7

79
99
122
145
179
311
459
652

600 0025 002 3


600 0025 003 3
600 0025 004 3
600 0025 005 3
600 0025 007 3

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

48,0
72,0
96,0
120,0
168,0

9,4
10,3
11,0
12,4
14,2

120
151
202
253
314

600 0040 002 3


600 0040 004 3

2X4
4G4

77,0
154,0

10,6
12,7

183
299

ConCab kabel connects the world

417

CC-Therm 150C-385
Halogen-free, heat-resistant EVA single core 450/750V
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 385 150 C

Technical data
Rated voltage:
up to 1,0 mm : 450/750 V
from 1,5 mm : 0,6/1 kV

The CC-Therm 150C-385 is particularly suitable to


be used in environmental conditions with high
operating temperatures as well as great temperature
fluctuations. They are ideal for use in buildings
stipulating a high level of protection for humans and
goods, as they exude very low non-toxic burning
gases which in any case do not have a corrosive
effect. The single core has a very good resistance to
atmospheric corrosion and may therefore be used in
damp surroundings and outdoors.

Construction
Fine strands of tinned copper wire, EVA based core
insulation, halogen-free,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).

418

Test voltage:
up to 1,0 mm : 2500 V
from 1,5 mm : 3500 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
flexible application:
short-term:

Temperature range:
-50C to +150C
+170C

flexible application:

Bending radius:
5 X core diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281, 0282

ConCab kabel connects the world

Part-No.

385 00051 ..
385 00071 ..
385 00101 ..
385 00151 ..
385 00251 ..
385 00401 ..
385 00601 ..
385 01001 ..
385 01601 ..
385 02501 ..
385 03501 ..
385 05001 ..
385 07001 ..
385 09501 ..
385 12001 ..
385 15001 ..
385 18501 ..

Crosssection

0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

4,8
7,2
9,6
14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0

2,2
2,4
2,5
3,0
3,6
4,3
4,9
6,6
7,7
9,6
10,7
12,6
14,9
17,2
19,6
20,9
24,4

9
12
14
21
31
47
73
125
185
280
370
540
730
990
1250
1650
1750

Please complete the Part-No. .. (when) ordering with the following specifications = colour
00 black
01 blue
02 brown
03 red

04 white
05 grey
06 violet
07 pink

08 orange
09 yellow
10 green

11 beige
12 dark blue
99 green/yellow

ConCab kabel connects the world

419

CC-Therm 150C-371
Halogen-free, heat-resistant EVA-control cable 450/750 V
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 371 5G1,5 150C

The CC-Therm 150C-371 is suitable as a control


cable in environmental conditions with unusual high
temperatures. It can be used in machine tools, plant
and apparatus construction, heating, air-conditioning
and ventilation technology as well as in additional
sectors of electronic equipment. The halogen-free
control cable is for use in buildings stipulating a high
level of protection for humans and goods, as they
exude very low non-toxic burning gases which in any
case do not have a corrosive effect. The black
outer sheath is extensively resistant to UV radiation
and ozone. The cable has a very good resistance to
atmospheric corrosion and may therefore be used in
damp surroundings and outdoors.

Construction
Fine strands of tinned copper wire, EVA based core
insulation, core colours acc. to DIN VDE 0293,
part 308, cores twisted in layers, foil wrapping. Outer
sheath based on EVA, halogen-free, flame retardant
and self- extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour black.

420

Technical data
Rated voltage:
450/750 V
Test voltage:
2500 V
Conductor stranding:
fine copper stands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km
flexible application:
short-term:

Temperature range:
-50C to +150C
+170C

flexible application:

Bending radius:
10 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

371 0005 002 00


371 0005 003 00
371 0005 004 00
371 0005 005 00

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

9,6
14,4
19,2
24,0

5,8
6,2
6,9
7,5

45
63
79
90

371 0007 002 00


371 0007 003 00
371 0007 004 00
371 0007 005 00

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
29,0
36,0

6,3
6,8
7,6
8,4

58
70
88
117

371 0010 002 00


371 0010 003 00
371 0010 004 00
371 0010 005 00

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,2
29,0
38,0
48,0

6,6
7,2
7,8
8,8

66
87
104
130

371 0015 002 00


371 0015 003 00
371 0015 004 00
371 0015 005 00
371 0015 007 00

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5

29,0
43,0
58,0
72,0
101,0

8,0
8,4
9,2
10,1
11,8

81
109
147
171
200

371 0025 002 00


371 0025 003 00
371 0025 004 00
371 0025 005 00
371 0025 007 00

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

48,0
72,0
96,0
120,0
168,0

9,0
9,6
10,7
11,9
13,4

130
171
205
261
306

371 0040 003 00


371 0040 004 00
371 0040 005 00
371 0040 007 00

3G4
4G4
5G4
7G4

115,0
154,0
192,0
269,0

11,7
13,2
14,7
16,8

250
293
400
438

371 0060 003 00

3G6

173,0

13,5

280

ConCab kabel connects the world

421

CC-Therm 150C-C-372
Halogen-free, heat-resistant EVA-control cable, shielded
Conforms to the EC low voltage guideline 73/23/EEC.

ConCab kabel Mainhardt 372 3G1,5 150C

The CC-Therm 150C-C-372 shielded is suitable as a


control cable in environmental conditions with
unusual high temperatures. It can be used in machine
tools plant and apparatus construction, heating,
air-conditioning and ventilation technology as well as
in additional sectors of electronic equipment.
The halogen-free control cable is for use in buildings
stipulating a high level of protection for humans and
goods, since the cable exudes very low non-toxic
burning gases which in any case do not have a
corrosive effect. The black outer sheath is extensively
resistant to UV radiation and ozone. The cable has a
very good resistance to atmospheric corrosion and
may therefore be used in damp surroundings and
outdoors. The overall copper shield ensures a reliable
transmission of data or impulses and protects the
cable against electrical interferences and disturbances.

Technical data
Rated voltage:
450/750 V
Test voltage:
2500 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 20 MOhm X km

Construction
Fine strands of tinned copper wire,
EVA based core insulation, core colours acc. to
DIN VDE 0293, part 308, 6 cores or more black with
white numbering and a green/yellow
protective conductor, cores twisted in layers, foil
tinned copper shield. Outer sheath based on EVA,
halogen-free, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1). Colour black.

422

flexible application:
short-term:

Temperature range:
-50C to +150C
+170C

flexible application:

Bending radius:
10 X cable diameter

Approvals:
acc. to DIN VDE 0245, 0250, 0281, 0282

ConCab kabel connects the world

Part-No.

No. of
cores
+
crosssection

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

372 0005 002


372 0005 003
372 0005 004
372 0005 005

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

36,0
43,0
51,0
58,0

6,7
7,1
7,8
8,4

85
96
105
118

372 0007 002


372 0007 003
372 0007 004
372 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

45,0
53,0
64,0
74,0

7,2
7,7
8,5
9,3

90
110
125
142

372 0010 002


372 0010 003
372 0010 004
372 0010 005

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

51,0
63,0
76,0
91,0

7,5
8,1
8,7
9,7

102
128
148
172

372 0015 002


372 0015 003
372 0015 004
372 0015 005
372 0015 007

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5

65,0
88,0
107,0
128,0
162,0

8,9
9,3
10,1
11,0
13,5

132
167
177
208
290

372 0025 002


372 0025 003
372 0025 004
372 0025 005
372 0025 007

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

92,0
123,0
149,0
176,0
253,0

9,9
10,5
11,6
12,8
16,3

175
199
240
287
430

372 0040 003


372 0040 004
372 0040 005

3G4
4G4
5G4

179,0
237,0
280,0

12,5
13,6
14,4

400
450
552

ConCab kabel connects the world

423

CC-Solar 120C-387
Halogen-free, heat-resistant single core 0,6/1 kV
Conforms to the EC low voltage guideline 73/23/EEC

ConCab SOLAR 120C -387 PV1-F VDE Reg. Nr. 8277

Technical data
Rated voltage:
0,6/1 kV
Test voltage:
8000 V
Conductor stranding:
fine copper strands
acc. to DIN EN 60228, class 5
Core insulation:
cross-linked, halogen-free elastomere

The CC-Solar-120 is specially designed for the


connection of solar modules. It is used for fixed
installation and flexible application without tensile
load.To ensure extraordinary security and quality, the
cable is approved by the worldwide recognized
VDE TV organization.

Construction
Fine strands of tinned copper wire, cross-linked
halogen-free core insulation, halogen-free, flame
retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).

424

Outer sheath:
cross-linked, halogen-free elastomere acc. to
DIN VDE 0266
weather and UV-resistant,
flame retardant, mat black (RAL 9005)
Insulation resistance:
at +20C min. 800 MOhm
fixed installation:
flexible application:

Temperature range:
-50C up to +150C
-25C up to +125C

fixed installation:
flexible application:

Bending radius:
5 X cable diameter
10 X cable diamter

ConCab kabel connects the world

Part-No.

Crosssection

Core
identification

mm2

Copper
weight

Outer
diameter
approx.

Weight

kg/km

mm

kg/km

387 0250 010


387 0250 011
387 0250 012
387 0250 312
387 0250 112

2,5
2,5
2,5
2,5
2,5

+
black
red
blue

24,0
24,0
24,0
24,0
24,0

4,5
4,5
4,5
4,5
4,5

40
40
40
40
40

387 0400 010


387 0400 011
387 0400 012
387 0400 312
387 0400 112

4
4
4
4
4

+
black
red
blue

38,4
38,4
38,4
38,4
38,4

5,2
5,2
5,2
5,2
5,2

59
59
59
59
59

387 0600 010


387 0600 011
387 0600 012
387 0600 312
387 0600 112

6
6
6
6
6

+
black
red
blue

57,6
57,6
57,6
57,6
57,6

5,9
5,9
5,9
5,9
5,9

81
81
81
81
81

387 1000 010


387 1000 011
387 1000 012
387 1000 312
387 1000 112

10
10
10
10
10

+
black
red
blue

96,0
96,0
96,0
96,0
96,0

6,9
6,9
6,9
6,9
6,9

127
127
127
127
127

387 1600 010


387 1600 011
387 1600 012
387 1600 312
387 1600 112

16
16
16
16
16

+
black
red
blue

151,1
151,1
151,1
151,1
151,1

8,3
8,3
8,3
8,3
8,3

193
193
193
193
193

387 2500 010


387 2500 011
387 2500 012
387 2500 312
387 2500 112

25
25
25
25
25

+
black
red
blue

234,0
234,0
234,0
234,0
234,0

9,6
9,6
9,6
9,6
9,6

284
284
284
284
284

387 3500 010


387 3500 011
387 3500 012
387 3500 312
387 3500 112

35
35
35
35
35

+
black
red
blue

315,7
315,7
315,7
315,7
315,7

11,0
11,0
11,0
11,0
11,0

378
378
378
378
378

ConCab kabel connects the world

425

CC-silicone single cores


SiF, SiF/GL, SiD, SiD/GL, SiFF
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 335 SiD

Technical data
Rated voltage:
300/500 V
Test voltage:
2000 V
The halogen-free silicone single cores are particular
resistant to high temperature and especially suitable to
be used in environmental conditions where high
operating temperatures as well as great
temperature fluctuations occur.

Conductor stranding:
SiF, SiF/GL:
fine tinned copper strands
acc. to DIN VDE 0295, class 5

Construction

SiD, SiD/GL:
solid tinned copper wire
acc. to DIN VDE 0295, class 1

SiF:
Fine strands of tinned copper wire,
silicone based core insulation.
SiF/GL:
Fine strands of tinned copper wire,
silicone based core insulation.
Impregnated glass fibre braiding
(in accordance to H05SJ-K).
SiD:
Solid tinned copper wire,
silicone based core insulation.
SiD/GL:
Solid tinned copper wire,
silicone based core insulation.
Impregnated glass fibre braiding.
SiFF:
Superfine strands of tinned copper wire.
Silicone based core insulation.

426

SiFF:
superfine tinned copper strands
acc. to DIN VDE 0295, class 6
Insulation resistance:
min. 200 MOhm X km
Temperature range:
-60C to +180C
short-term: +220C
fixed installation:
flexible application:

ConCab kabel connects the world

Bending radius:
6 X core diameter
15 X core diameter

Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

Crosssection

kg/km

kg/km

SiF:
325 0002 ..
325 0005 ..
325 0007 ..
325 0010 ..
325 0015 ..
325 0025 ..
325 0040 ..
325 0060 ..
325 0100 ..
325 0160 ..
325 0250 ..
325 0350 ..
325 0500 ..
325 0700 ..
325 0950 ..
325 1200 ..
325 1500 ..
325 1850 ..

0,25
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0

Copper
weight

Outer
diameter
approx.
mm

Weight

2,0
2,2
2,3
2,6
3,2
3,9
4,5

7,5
10,5
13,0
18,0
29,0
45,0
64,5

2,5
2,7
2,8
3,1
3,7
4,4
4,9

10
15
19
28
40
55
80

1,9
2,2
2,4
2,7
3,1
3,8
4,7
5,6
7,0
8,5

5,4
8,0
11,2
13,5
18,5
30,0
47,5
71,0
120,0
187,5

kg / km

SiD:
2,4
4,8
7,2
9,6
14,4
24,0
38,4
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0

1,9
2,1
2,4
2,5
2,8
3,4
4,2
5,0
6,6
7,4
9,2
10,3
12,2
14,2
16,6
18,0
20,0
22,5

5,4
8,0
11,2
13,5
18,5
30,0
47,5
71,0
120,0
187,5
289,0
398,5
559,0
766,0
1031,5
1285,0
1563,0
1915,0

335 0005 ..
335 0007 ..
335 0010 ..
335 0015 ..
335 0025 ..
335 0040 ..
335 0060 ..

0,50
0,75
1,0
1,5
2,5
4,0
6,0

4,8
7,2
9,6
14,4
24,0
38,4
58,0
SiD/GL:

336 0005 ..
336 0007 ..
336 0010 ..
336 0015 ..
336 0025 ..
336 0040 ..
336 0060 ..

0,50
0,75
1,0
1,5
2,5
4,0
6,0

4,8
7,2
9,6
14,4
24,0
36,0
58,0
SiFF:

SiF/GL:
330 0002 ..
330 0005 ..
330 0007 ..
330 0010 ..
330 0015 ..
330 0025 ..
330 0040 ..
330 0060 ..
330 0100 ..
330 0160 ..
330 0250 ..
330 0350 ..
330 0500 ..

0,25
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0

2,4
4,8
7,2
9,6
14,4
24,0
38,4
58,0
96,0
154,0
240,0
336,0
480,0

2,4
2,8
3,2
3,4
3,9
4,5
5,2
5,9
7,9
9,2
10,9
12,2
14,3

8,0
12,5
16,0
18,5
23,5
36,0
53,0
77,0
129,0
198,5
303,5
414,0
578,5

340 0002 ..
340 0005 ..
340 0007 ..
340 0010 ..
340 0015 ..
340 0025 ..
340 0040 ..
340 0060 ..
340 0100 ..
340 0160 ..

0,25
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0

2,4
4,8
7,2
9,6
14,4
24,0
38,4
58,0
96,0
154,0

Please complete the Part-No. .. when ordering


with following specifications = colour
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

10 green
11 beige
41 redbrown
50 transparent (natural)
99 green/yellow

Additional colours on request

ConCab kabel connects the world

427

CC-silicone single cores-353


Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 335 SiD

Technical data
Rated voltage:
600 V
Test voltage:
2000 V
Conductor stranding:
SiF:
fine tinned copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km

The halogen-free silicone single cores with UL and


CSA are particular resistant to high temperature and
especially suitable to be used in environmental
conditions where high operating temperatures as well
as great temperature fluctuations occur.

Construction
SiF:
Fine strands of tinned copper wire, silicone based
core insulation. Other specifications (stranding,
termperature etc) on request.

428

Temperature range:
-50C to +200C
short-term: +220C
fixed installation:
flexible application:

ConCab kabel connects the world

Bending radius:
6 X core diameter
15 X core diameter

Approvals:
acc. to UL/CSA Style 3530

Part-No.

AWG

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

5,6
7,8
8,6
10,0
11,1
13,6
15,6
17,6

81
140
202
300
406
580
792
1052

kg/km

SiF:
3530101 ..
3530081 ..
3530061 ..
3530041 ..
3530021 ..
3530011 ..
3530201 ..
3530301 ..

10
8
6
4
2
1
2/0
3/0

58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0

Please complete the Part-No. .. when ordering


with following specifications = colour
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

10 green
11 beige
41 redbrown
50 transparent (natural)
99 green/yellow

Additional colours on request

ConCab kabel connects the world

429

CC-silicone single core-386


Halogen-free with synthetic yarn braid, 1,1 kV - 13,8 kV

ConCab kabel Mainhardt 386 Si - 3,3 kV

Technical data
Rated voltage:
1,1 kV
3,3 kV
6,6 kV
13,8 kV

The high temperature resistant, halogen-free


CC-silicone single core-386 is specially designed for
wiring motors, generators, transformers, current
converters as well as in ship-building and railroad
construction.

Construction
Fine strands of tinned copper wire,
as of 6,6 kV with semi-conductor tape over the
strands to smooth conductor, silicone based core
insulation, synthetic yarn braid covered with lacquer
based on a PUR-basis, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 332-1).
Colours:
1,1 kV
yellow
3,3 kV
redbrown
6,6 kV
grey
13,8 kV
black

430

Test voltage:
3,5 kV
10,0 kV
15,0 kV
30,0 kV
Conductor stranding:
fine tinned copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km
Temperature range:
flexible application: -60C to +180C
short-term: +230C

ConCab kabel connects the world

Bending radius:
5 X core diameter
Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

Crosssection

kg/km

kg/km

1,1 kV
386 0015 11
386 0025 11
386 0040 11
386 0060 11
386 0100 11
386 0160 11
386 0250 11
386 0350 11
386 0500 11
386 0700 11
386 0950 11
386 1200 11
386 1500 11
386 1850 11
386 2400 11

1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

Outer
diameter
approx.
mm

Weight

8,0
8,5
9,4
11,3
13,0
14,2
16,5
18,5
20,2
22,2
24,2
26,2
28,6

90
110
170
200
315
415
600
785
1030
1275
1585
2020
2460

11,1
12,1
14,0
15,6
16,8
18,7
20,7
22,5
24,4
26,7
28,7
30,1

165
220
305
346
495
655
865
1120
1370
1650
1980
2620

kg / km

6,6 kV
4,1
4,5
5,0
5,5
6,4
8,5
10,5
11,8
14,1
16,1
18,3
20,2
22,5
24,9
27,3

26
37
60
75
120
200
295
400
515
710
930
1270
1444
1850
2435

3,3 kV
386 0025 33
386 0040 33
386 0060 33
386 0100 33
386 0160 33
386 0250 33
386 0350 33
386 0500 33
386 0700 33
386 0950 33
386 1200 33
386 1500 33
386 1850 33
386 2400 33

Copper
weight

6,3
6,9
7,3
8,3
10,4
12,0
13,2
15,5
17,5
19,9
21,8
23,7
25,7
28,1

57
75
100
150
215
305
360
550
745
990
1280
1500
1845
2455

386 0040 66
386 0060 66
386 0100 66
386 0160 66
386 0250 66
386 0350 66
386 0500 66
386 0700 66
386 0950 66
386 1200 66
386 1500 66
386 1850 66
386 2400 66

4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
13,8 kV

386 0060 138


386 0100 138
386 0160 138
386 0250 138
386 0350 138
386 0500 138
386 0700 138
386 0950 138
386 1200 138
386 1500 138
386 1850 138
386 2400 138

6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

ConCab kabel connects the world

58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

431

CC-silicone single core


Temperature resistant H05SJ-K, H05S-U, H05S-K
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 331 H05S-K

Technical data
Rated voltage:
300/500 V
Test voltage:
2000 V
The halogen-free, harmonized CC-silicone single
cores are due to their resistance to high temperatures
particularly suitable to be used in environmental
conditions where high operating temperatures as well
as great temperature fluctuations occur.

Construction

Conductor stranding:
H05SJ-K, H05S-K:
fine copper strands
acc. to DIN VDE 0295, class 5
H05S-U:
Single copper wire
acc. to DIN VDE 0295, class 1
Insulation resistance:
min. 200 MOhm X km

H05SJ-K:
Fine strands of tinned copper wire,
silicone based core insulation,
impregnated glass-fibre braiding.

432

Temperature range:
-60C to +180C

H05S-K:
Fine strands of tinned copper wire,
silicone based core insulation.

Bending radius:
15 X core diameter

H05S-U:
Solid, tinned copper wire,
silicone based core insulation.

Approvals:
acc. to DIN VDE 0282, part 3 resp.
HD 22.3 S3

ConCab kabel connects the world

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

2,7
3,0
3,1
3,5
4,2
4,8
5,3
7,6
8,6

14
17
19
25
37
53
71
134
201

2,7
2,9
3,0
3,6
4,3

9
12
14
20
31

2,6
2,8
2,9
3,4
4,0

8
11
13
18
29

kg/km

H05SJ-K:
331 0005 ..
331 0007 ..
331 0010 ..
331 0015 ..
331 0025 ..
331 0040 ..
331 0060 ..
331 0100 ..
331 0160 ..

0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0

4,8
7,2
9,6
14,4
24,0
38,4
57,6
96,0
153,6
H05S-K:

332 0005 ..
332 0007 ..
332 0010 ..
332 0015 ..
332 0025 ..

0,50
0,75
1,0
1,5
2,5

4,8
7,2
9,6
14,4
24,0
H05S-U:

333 0005 ..
333 0007 ..
333 0010 ..
333 0015 ..
333 0025 ..

0,50
0,75
1,0
1,5
2,5

4,8
7,2
9,6
14,4
24,0

Please complete the Part-No. .. when ordering


with following specifications = colour
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

10 green
11 beige
41 redbrown
50 transparent (natural)
99 green/yellow

Additional colours on request

ConCab kabel connects the world

433

CC-Silicone-twin cable SiZ-341


CC-Silicone-ignition circuit cable FZL-Si-326
CC-Silicone-ignition circuit cable FZL-Si/GL/Si-327
ConCab kabel Mainhardt 341 SiZ

ConCab kabel Mainhardt 326 FZL-SI

Technical data
SiZ:
FZL:
The halogen-free silicone twin cable SiZ and the
ignition circuit cable FZL-Si, FZL-Si/GLS are due to
their high resistance to high termperature particularly
suitable to be used in environmental conditions where
high operating temperatures as well as great
temperature fluctuations occur. To protect from
mechanical stress, the FZL-Si/GL/Si has a fibre glass
braiding covered with an additional silicone sheath.

Construction

Impulse peak voltage:


FZL:
20 kV
SiZ:
FZL:

FZL-Si/GL/Si:
Fine strands of tinned copper wire, reinforced
silicone based core insulation, glass-fibre braiding,
additional outer sheath based on silicone.

434

Test voltage:
2 kV
20 kV

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km

SiZ:
Fine strands of tinned copper wire, silicone insulations, 2 parallel running separable cores.
FZL-Si:
Fine strands of tinned copper wire, reinforced
silicone based core insulation.

Rated voltage:
300/500 V
10 kV

Temperature range:
-60C up to +180C
short-term:up to +220C
fixed installation:
flexible application:

ConCab kabel connects the world

Bending radius:
6 X cable diameter
15 X cable diameter

Norms:
acc. to DIN VDE 0250, 0282

Part-No.

No. of cores
+
crosssection

Copper
Outside Weight
weight dimensions/

kg/km approx. mm kg/km


SiZ:

341 0005 ..
341 0007 ..
341 0010 ..
341 0015 ..

2 X 0,50
2 X 0,75
2 X 1,0
2 X 1,5

9,6
14,4
19,2
28,8

2,1 X 4,2
2,4 X 4,8
2,5 X 5,0
2,8 X 5,8

16,3
21,5
27,0
37,0

6,1
6,6
7,1
7,6

51
61
72
84

8,0
8,9

65
88

FZL-Si:
326 0005 ..
326 0007 ..
326 0010 ..
326 0015 ..

0,50
0,75
1,0
1,5

4,8
7,2
9,6
14,4
FZL-Si/GL/Si:

327 0010 ..
327 0015 ..

1,0
1,5

9,6
14,4

Please complete the Part-No. .. when ordering


with following specifications = colour
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

10 green
11 beige
41 redbrown
50 transparent (natural)
99 green/yellow

Additional colours on request

ConCab kabel connects the world

435

CC-silicone cable SiHF-610


Temperature resistant silicone cable
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 610 5G2,5 SiHF

Technical data
Rated voltage:
300/500 V
Test voltage:
2000 V
The CC-silicone cable SiHF-610 is suitable for use in
ovens, electric motors and aircraft constructions, iron
and steel works as well as in hot-rolling mills and in
similar areas where high temperatures and extreme
temperature fluctuations occur. The silicone outer
sheath is halogen-free, flame retardant as well as
resistant to UV radiation and to a large number of oil,
acid and lye.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km
Temperature range:
-60C to +180C
short-term: +220C

Construction
Fine tinned strands of copper wire, silicone core
insulation, cores colours acc. to DIN VDE 0293, part
308*, 3 cores or more with green/yellow protective
conductor in the outer layer, cores twisted in layers.
Outer sheath based on silicone. Colour redbrown.

fixed installation:
flexible application:

*6 cores or more black with white numbering

436

ConCab kabel connects the world

Bending radius:

4 X cable diameter
15 X cable diameter

Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

No. of cores
+
crosssection

Copper
weight

610 0005 002


610 0005 003
610 0005 004
610 0005 005

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

9,6
14,4
19,2
24,0

5,6
5,9
6,5
7,3

45
54
65
83

610 0007 002


610 0007 003
610 0007 004
610 0007 005
610 0007 006
610 0007 007

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
6 G 0,75
7 G 0,75

14,4
21,6
29,0
36,0
43,2
50,4

6,4
6,8
7,6
8,5
9,2
9,2

60
71
91
114
134
139

610 0010 002


610 0010 003
610 0010 004
610 0010 005
610 0010 006
610 0010 007

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
6 G 1,0
7 G 1,0

19,2
29,0
38,4
48,0
58,0
67,0

6,6
7,0
7,9
8,8
9,5
9,5

67
81
104
130
153
161

610 0015 002


610 0015 003
610 0015 004
610 0015 005
610 0015 006
610 0015 007
610 0015 008
610 0015 012
610 0015 016
610 0015 018
610 0015 020
610 0015 024

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
6 G 1,5
7 G 1,5
8 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
20 G 1,5
24 G 1,5

29,0
43,2
58,0
72,0
87,0
101,0
115,2
173,0
231,0
259,2
288,0
346,0

7,6
8,0
8,8
9,6
10,4
10,4
11,3
14,0
16,2
17,0
17,5
19,8

92
111
137
167
197
208
242
371
493
549
592
741

kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

610 0025 002


610 0025 003
610 0025 004
610 0025 005
610 0025 006
610 0025 007
610 0025 012

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
6 G 2,5
7 G 2,5
12 G 2,5

48,0
72,0
96,0
120,0
144,0
168,0
288,0

8,8
9,7
10,6
11,6
12,6
12,6
17,1

131
171
212
258
305
324
581

610 0040 002


610 0040 003
610 0040 004
610 0040 005
610 0040 006
610 0040 007

2X4
3G4
4G4
5G4
6G4
7G4

76,8
115,2
154,0
192,0
231,0
269,0

10,8
11,5
12,6
14,0
15,6
15,6

200
248
310
386
473
502

610 0060 002


610 0060 003
610 0060 004
610 0060 005
610 0060 007

2X6
3G6
4G6
5G6
7G6

116,0
173,0
230,4
288,0
403,2

12,4
13,2
14,7
16,6
18,6

275
344
439
556
730

610 0100 003


610 0100 004
610 0100 005

3 G 10
4 G 10
5 G 10

288,0
384,0
480,0

17,3
19,4
21,6

568
731
908

610 0160 004


610 0160 005

4 G 16
5 G 16

614,0
768,0

21,4
24,0

1043
1308

610 0250 004

4 G 25

960,0

26,4

1621

kg/km

ConCab kabel connects the world

kg / km

437

CC-silicone cable SiHF-610


Temperature resistant silicone cable
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 610 5G2,5 E172073 cus AWM STYLE 4389 600V 150C

Technical data
Rated voltage:
DIN VDE/IEC: 300/500 V
UL/CSA:
600 V
Test voltage:
2000 V
The CC-silicone cable SIHF-610 UL/CSA approved,
is suitable for use in ovens, electric motors and
aircraft constructions, iron and steel works as well as
in hot-rolling mills and in similar areas where high
temperatures and extreme temperature fluctuations
occur. The silicone outer sheath is halogen-free, flame
retardant as well as resistant to UV radiation and to a
large number of oil, acid and lye.

Construction
Fine tinned strands of copper wire, silicone core
insulation, core colours acc. to DIN VDE 0293, part
308*, 3 cores or more with green/yellow protective
conductor in the outer layer, cores twisted in layers.
Outer sheath based on silicone.
Colour redbrown.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km
Temperature range:
DIN VDE/IEC : -60C to 180C
short-term: +200C
UL/CSA : -50C to +150C
Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

*6 cores or more black with white numbering

438

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250,0282
cUL-Style: 3529, 4476, 4389

Part-No.

No. of cores
+

Copper
weight

Outer
diameter
approx.

Weight

mm

kg/km

Part-No.

No. of cores

Copper
weight

Outer
diameter
approx.

Weight

mm2/AWG

kg/km

mm

kg / km

610 14 02
610 14 03
610 14 04
610 14 05
610 14 06
610 14 07
610 14 12

2 X 2,5/14
3 G 2,5/14
4 G 2,5/14
5 G 2,5/14
6 G 2,5/14
7 G 2,5/14
12 G 2,5/14

48,0
63,0
96,0
120,0
144,0
168,0
288,0

9,8
10,5
11,5
12,6
13,7
13,7
21,2

143
173
219
270
316
333
557

610 12 02
610 12 03
610 12 04
610 12 05
610 12 07

2 X 4/12
3 G 4/12
4 G 4/12
5 G 4/12
7 G 4/12

76,8
115,2
154,0
192,0
269,0

11,1
11,9
13,1
14,4
17,9

190
224
295
359
480

610 10 02
610 10 03
610 10 04
610 10 05
610 10 07

2 X 6/10
3 G 6/10
4 G 6/10
5 G 6/10
7 G 6/10

116,0
173,0
230,0
288,0
403,0

14,4
15,3
16,5
18,1
21,4

274
339
442
535
686

610 08 03
610 08 04
610 08 05

3 G 10/8
4 G 10/8
5 G 10/8

288,0
384,0
480,0

18,8
19,9
22,3

614
745
907

610 06 04
610 06 05

4 G 16/6
5 G 16/6

614,0
768,0

25,1
26,7

988
1180

610 04 04

4 G 25/4

960,0

32,4

1481

mm2/AWG

kg/km

610 20 02
610 20 03
610 20 04
610 20 05

2 X 0,5/20
3 G 0,5/20
4 G 0,5/20
5 G 0,5/20

9,6
14,4
19,2
24,0

7,8
8,2
8,7
9,4

75
83
51
62

610 18 02
610 18 03
610 18 04
610 18 05
610 18 06
610 18 07

2 X 1,0/18
3 G 1,0/18
4 G 1,0/18
5 G 1,0/18
6 G 1,0/18
7 G 1,0/18

19,2
29,0
38,4
48,0
58,0
67,0

8,3
9,1
9,9
10,5
11,5
11,5

87
113
132
160
184
202

610 16 02
610 16 03
610 16 04
610 16 05
610 16 06
610 16 07
610 16 08
610 16 12
610 16 16
610 16 18
610 16 20
610 16 24

2 X 1,5/16
3 G 1,5/16
4 G 1,5/16
5 G 1,5/16
6 G 1,5/16
7 G 1,5/16
8 G 1,5/16
12 G 1,5/16
16 G 1,5/16
18 G 1,5/16
20 G 1,5/16
24 G 1,5/16

29,0
43,0
58,0
72,0
87,0
101,0
115,0
173,0
231,0
259,0
288,0
346,0

9,2
9,7
10,7
11,4
12,5
12,5
14,0
16,5
20,1
20,7
21,6
23,7

115
133
167
201
243
260
301
429
566
655
722
908

ConCab kabel connects the world

439

CC-silicone cable H05SS-F-611


Temperature resistant silicone cable acc. to HAR
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 611 5G1,5 H05SS-F <HAR>

Technical data
The harmonized CC-silicone cable
H05SS-F-611 is suitable for use in ovens, electric
motors and aircraft construction, iron and steel works
as well as in hot-rolling mills, bakeries, solariums,
saunas and in similar facilities where high
temperatures and extreme differences in temperature
occur with improved characteristics against
mechanical stress. It is furthermore ideal for
permanent mechanically protected cabling for lighting
in industrial applications and is resistant to a
large number of oil, acid and lye.

Rated voltage:
300/500 V
Test voltage:
2000 V
Conductor stranding:
Fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km

Construction
Fine bare or tinned strands of copper wire,
cross-linked silicone mixture (EI 2), core colours
acc. to DIN VDE 0293 part 308. 3 cores or more with
green/yellow protective conductor in the outer layer,
cores twisted in layers. The outer sheath is based on
cross-linked silicone mixture (EM 9), flame retardant
and self-extinguishing (acc. to DIN VDE 0482, part
265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour black. Other sheath colours are
available on request.

440

Temperature range:
-60C to +180C
Short-term: +200C
Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter
Approvals:
acc. to DIN VDE 0282, part 15
HD 22.15 S1

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

611 0007 00200


611 0007 00300
611 0007 00400
611 0007 00500

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
28,8
36,0

5,7 6,2 6,8 7,6 -

7,4
8,1
8,8
9,9

54
68
88
103

611 0010 00200


611 0010 00300
611 0010 00400
611 0010 00500

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,2
29,0
38,4
48,0

6,1 6,5 7,1 8,0 -

8,0
8,5
9,3
10,3

87
113
132
160

611 0015 00200


611 0015 00300
611 0015 00400
611 0015 00500

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5

29,0
43,0
58,0
72,0

7,6 8,0 9,0 9,8 -

9,8
10,4
11,6
12,7

115
133
167
201

611 0025 00200


611 0025 00300
611 0025 00400
611 0025 00500

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5

48,0
72,0
96,0
120,0

9,0 9,6 10,7 11,9 -

11,6
12,4
13,8
15,3

143
173
219
270

611 0040 00300


611 0040 00400

3G4
4G4

115,2
154,0

11,3 - 14,5
12,7 - 16,2

224
295

611 0060 00300


611 0060 00400

3G6
4G6

173,0
230,0

12,8 - 16,3
14,2 - 18,1

339
442

ConCab kabel connects the world

441

CC-silicone cable Si-C-Si-614


Temperature resistant silicone cable, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 614 2x1,5 Si-C-Si

Technical data
Rated voltage:
DIN VDE/IEC: 300/500 V
Test voltage:
2000 V
The CC-silicone cable Si-C-Si-614 shielded, is
suitable for use in ovens, electric motors and aircraft
constructions, iron and steel works as well as in
hot-rolling mills, bakeries, solariums, saunas and in
similar facilities where high temperatures and extreme
differences in temperature occur and where a greater
demand for electromagnetic compatibility (EMC) is.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km

Construction
Fine strands of tinned copper wire, silicone insulation,
core colours acc. to DIN VDE 0293, part 308*, 3 cores
or more with green/yellow protective conductor in the
outer layer, cores twisted in layers, foil wrapping,
tinned copper shield. Outer sheath based on silicone.
Colour redbrown.

Temperature range:
-60C to +180C
Short-term: +200C
Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter

*6 cores or more black with white numbering

442

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250,0282

Part-No.

No. of cores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

614 0005 002


614 0005 003
614 0005 004
614 0005 005

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

26,0
31,0
36,0
56,0

6,4
6,7
7,1
7,9

60
68
76
100

614 0007 002


614 0007 003
614 0007 004
614 0007 005
614 0007 007

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
7 G 0,75

31,0
51,0
63,0
74,0
89,0

7,0
7,5
8,0
8,7
9,3

70
100
114
136
164

614 0010 002


614 0010 003
614 0010 004
614 0010 005
614 0010 007

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0

48,0
58,0
71,0
86,0
108,0

7,4
7,7
8,3
8,9
9,6

88
99
115
136
163

614 0015 002


614 0015 003
614 0015 004
614 0015 005
614 0015 007
614 0015 012
614 0015 016
614 0015 018

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5

61,0
81,0
96,0
114,0
152,0
241,0
302,0
363,0

8,2
8,5
9,1
10,0
10,8
14,2
15,6
17,0

106
125
145
175
220
342
428
515

614 0025 002


614 0025 003
614 0025 004
614 0025 005
614 0025 007

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

89,0
114,0
147,0
176,0
226,0

9,4
9,9
10,7
11,6
13,0

148
172
210
258
330

614 0040 004

4 G 4,0

204,0

13,6

361

614 0060 002


614 0060 003

2 X 6,0
3 G 6,0

165,0
230,0

13,4
14,2

304
388

ConCab kabel connects the world

443

CC-silicone cable Si-C-Si-614


Temperature resistant silicone cable, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 614 2X1,5 E172073 cus AWM STYLE 4476 600V 150C

Technical data
DIN VDE/IEC:
UL/CSA:

The CC-silicone cable Si-C-Si-614 shielded, UL/CSA


approved, is suitable for use in ovens, electric motors
and aircraft constructions, iron and steel works as well
as in hot-rolling mills, bakeries, solariums, saunas and
in similar facilities where high temperatures and
extreme differences in temperature occur and where a
greater demand for electromagnetic compatibility
(EMC) is.

Test voltage:
2000 V
Conductor stranding:
fine strands of tinned copper wires
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km
Temperature range:
-60C up to +180C
short-term: up to+200C

Construction
Fine strands of tinned copper wire, silicone
insulation, core colours acc. to DIN VDE 0293, part
308*, 3 cores or more with green/yellow
protective conductor in the outer layer, cores twisted
in layers, foil wrapping, tinned copper shield.
Outer sheath based on silicone.
Colour redbrown.

Bending radius:
fixed installation: 6 X cable diameter
flexible application: 20 X cable diameter

* 6 cores or more black with white numbering

444

Rated voltage:
300/500 V
600 V

ConCab kabel connects the world

Norms:
acc. to DIN VDE 0250, 0282
UL: Style 4476

Part-No.

No. of cores
+
Cross-section/
AWG

Copper
weight

Outerdiameterapprox.

Weight

kg/km

mm

kg/km

614 20 02
614 20 03
614 20 04
614 20 05

2 X 0,5/20
3 G 0,5/20
4 G 0,5/20
5 G 0,5/20

56
61
67
82

8,9
9,4
9,6
10,2

93
106
127
153

614 18 02
614 18 03
614 18 04
614 18 05
614 18 07

2 X 1,0/18
3 G 1,0/18
4 G 1,0/18
5 G 1,0/18
7 G 1,0/18

67
86
97
108
141

9,6
9,8
10,7
11,5
12,3

132
153
165
201
233

614 16 02
614 16 03
614 16 04
614 16 05
614 16 07
614 16 12

2 X 1,5/16
3 G 1,5/16
4 G 1,5/16
5 G 1,5/16
7 G 1,5/16
12 G 1,5/16

88
104
132
149
193
298

10,7
11,1
11,5
13,0
14,2
18,1

171
192
232
270
339
518

Part-No.

No. of cores
+
Cross-section/
AWG

Copperweight

Outerdiameter
approx.

Weight

kg/km

mm

kg / km

614 14 02
614 14 03
614 14 04
614 14 05
614 14 07

2 X 2,5/14
3 G 2,5/14
4 G 2,5/14
5 G 2,5/14
7 G 2,5/14

122
148
189
215
266

12,1
12,9
13,9
15,2
17,1

224
268
335
387
475

614 12 04

4 G 4/12

295

17,2

513

614 10 04

4 G 6/10

448

18,5

776

614 08 04

4 G 10/8

760

25,3

1279

ConCab kabel connects the world

445

CC-silicone cable SiHF-C-Si-616


Temperature resistant silicone cable, shielded
Conforms to the EC low voltage guideline 73/23/EEC

ConCab kabel Mainhardt 616 2X2,5

Technical data
Rated voltage:
DIN VDE/IEC: 300/500 V

The CC-silicone cable SiHF-C-Si-616 shielded, is suitable for use in ovens, electric motors and aircraft
constructions, iron and steel works as well as in
hot-rolling mills, bakeries, solariums, saunas and in
similar facilities where high temperatures and extreme
differences in temperature occur and where a greater
demand for electromagnetic compatibility (EMC) is.

Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km

Construction
Fine strands of tinned copper wire, silicone
insulation, core colours acc. to
DIN VDE 0293, part 308*, 3 cores or more with
green/yellow protective conductor in the outer layer,
cores twisted in layers, inner sheath, tinned
copper shield. Outer sheath based on silicone.
Colour redbrown.

Temperature range:
-60C to +180C
Short-term: +200C
Bending radius:
fixed installation: 4 X cable diameter
flexible application: 15 X cable diameter

* 6 cores or more black with white numbering

446

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250,0282

Part-No.

No. of
cores
+
Crosssection

Copper
weight

Outerdiameter
approx

Weight

kg/km

mm

kg/km

616 0007 002


616 0007 003
616 0007 004
616 0007 005

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

37,5
46,1
57,3
67,3

8,6
8,9
10,2
10,9

104
118
152
176

616 0010 002


616 0010 003
616 0010 004
616 0010 005
616 0010 007

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
7 G 1,0

43,0
55,7
67,8
80,3
113,9

9,0
9,7
10,9
11,6
12,3

116
142
175
203
250

616 0015 002


616 0015 003
616 0015 004
616 0015 005
616 0015 007
616 0015 008
616 0015 012
616 0015 016
616 0015 018
616 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
8 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
25 G 1,5

58,0
74,0
91,4
121,7
157,2
189,0
285,0
357,0
388,0
477,0

10,8
11,2
12,0
12,9
14,2
15,2
17,9
19,8
20,7
23,8

166
188
222
273
341
374
515
648
705
784

Part-No.

No. of
cores
+
Crosssection

Copper
weight

Outerdiameter
approx

Weight

kg/km

mm

kg/km

616 0025 002


616 0025 003
616 0025 004
616 0025 005
616 0025 007

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

91,5
121,2
150,9
180,5
254,0

12,0
12,8
13,9
15,0
16,6

249
271
328
387
421

616 0040 003


616 0040 004
616 0040 005

3G4
4G4
5G4

172,0
218,0
263,0

14,3
15,9
17,1

358
438
528

616 0060 003


616 0060 004
616 0060 005

3G6
4G6
5G6

241,0
305,0
370,0

16,3
17,7
19,3

484
585
697

ConCab kabel connects the world

447

CC-silicone cable SiHF-GLS-630


Temperature resistant silicone cable with steel wire braid
Conforms to the EC low voltage guideline 73/23/EEC

Technical data
The CC-silicone cable SiHF-GLS-630
contains a galvanized steel wire braid that
affords temperature stability and an improved
protection against mechanical impact. It is suitable
for use in ovens, electric motors and aircraft
constructions, iron and steel works as well as in
hot-rolling mills and other areas where high
temperatures and extreme differences in temperature
occur. The cable is halogen-free, flame retardant and
as well resistant to UV radiation and a large number
of oil, acid and lye.

Rated voltage:
300/500 V
Test voltage:
2000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Insulation resistance:
min. 200 MOhm X km
Temperature range:
-60C to +180C
short-term: +220C

Construction
Fine strands of tinned copper wire, silicone core
insulation, cores coloured acc. to DIN VDE 0293, part
308*, 3 cores or more with green/yellow protective
conductor in the outer layer, cores twisted in layers.
Outer sheath based on silicone. Colour redbrown,
glass-fibre braid and galvanized steel wire braid.

Bending radius:
fixed installation: 4 X cable diameter
flexible application: 20 X cable diameter

*6 cores or more black with white numbering

448

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250, 0282

Part-No.

No. of cores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

kg/km

630 0007 002


630 0007 003
630 0007 004
630 0007 005
630 0007 006
630 0007 007

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75
6 G 0,75
7 G 0,75

14,4
21,6
29,0
36,0
43,2
50,0

7,5
7,8
8,9
9,6
10,3
10,3

91
102
130
160
170
180

630 0010 002


630 0010 003
630 0010 004
630 0010 005
630 0010 006
630 0010 007

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0
6 G 1,0
7 G 1,0

19,2
29,0
38,4
48,0
58,0
67,0

7,9
8,7
9,3
10,0
10,9
10,9

98
122
142
167
188
199

630 0015 002


630 0015 003
630 0015 004
630 0015 005
630 0015 006
630 0015 007
630 0015 012
630 0015 016
630 0015 018
630 0015 024
630 0015 025

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
6 G 1,5
7 G 1,5
12 G 1,5
16 G 1,5
18 G 1,5
24 G 1,5
25 G 1,5

29,0
43,0
58,0
72,0
87,0
101,0
173,0
230,0
259,0
348,0
360,0

8,8
9,4
10,0
11,0
11,7
11,7
15,5
17,6
18,4
21,2
21,4

127
145
173
202
240
244
328
576
636
843
865

630 0025 002


630 0025 003
630 0025 004
630 0025 005
630 0025 007

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

48,0
72,0
96,0
120,0
168,0

10,4
10,9
11,8
12,8
14,3

187
205
278
323
380

630 0040 003


630 0040 004
630 0040 005

3G4
4G4
5G4

115,2
154,0
192,0

12,6
14,3
17,4

311
348
454

630 0060 003


630 0060 004
630 0060 005

3G6
4G6
5G6

173,0
230,0
288,0

15,0
17,1
18,3

432
545
658

630 0100 004

4 G 10

384,0

22,0

925

630 0160 004

4 G 16

614,0

26,1

1235

630 0250 004

4 G 25

960,0

30,3

1701

ConCab kabel connects the world

449

CC-single core FEP/PTFE-348


Excellent temperature stability
acc. to MIL-W 16878 (metric dimensions)
Conforms to the EC low voltage guideline 73/23/EEC

Technical data
Rated voltage:
as listed in table
Test voltage:
as listed in table

The CC-single core FEP/PTFE-348


can be used in many fields where extreme
temperatures occur. It is exceptionally
resistant to oil, fat, acid, alkali and
solvents. Furthermore FEP/PTFE insulated
cores are light and weather resistant.

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
depending on temperature range
bare, tinned, silver-plated or nickel-plated

Construction
FEP:
Fine strands of bare, tinned and silver plated
copper wire, FEP based core insulation,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 332-1).
PTFE:
Fine strands of bare, tinned and silver plated or nickel
plated copper wire, PTFE based core insulation,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).

450

ConCab kabel connects the world

Conductor material:
bare: +130C
tinned: +180C
silver-plated: +200C
nickel-plated: +260C
Insulation resistance:
min. 1 GOhm X km
Temperature range:
FEP: -100C to +200C
Short-term: +230C
PTFE: -200C to +260C
Short-term: +300C
Bending radius:
10 X core diameter
Approvals:
acc. to MIL-W 16878

Part-No.

348 002. ...


348 003. ...
348 005. ...
348 007. ...
348 010. ...
348 015. ...
348 025. ...
348 040. ...
348 060. ...
348 100. ...
348 160. ...
348 250. ...
348 350. ...
348 500. ...
348 700. ...
348 950. ...

Cross-section
mm2

Conductor
stranding
+ x
mm

0,25
0,34
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0

14 X 0,15
7 X 0,25
16 X 0,20
24 X 0,20
32 X 0,20
30 X 0,25
50 X 0,25
56 X 0,30
84 X 0,30
80 X 0,40
126 X 0,40
196 X 0,40
276 X 0,40
392 X 0,40
356 X 0,50
470 X 0,50

Ratedvoltage250V
Testvoltage2500V
ET/KT

PleasecompletethePart-No.348....
whenorderingwiththefollowingspecifications:
Refertopartslist348-
Cross-section
Specification
Conductor
Colour
Example:
3480155 100=FEP1,5mm2,600V,
Cu-silver-plated,Colourblack

0,90 - 1,00
1,02 - 1,12
1,22 - 1,32

Corediametermm(min.-max.)
Ratedvoltage600V
Ratedvoltage1000V
Testvoltage3400V
Testvoltage5000V
E/K
EE/KK
1,05
1,17
1,37
1,65
1,85
2,10
2,65
3,30
3,95
5,50
6,50
8,30
9,50
11,00
13,00
15,85

- 1,25
- 1,37
- 1,58
- 1,85
- 2,05
- 2,30
- 2,85
- 3,50
- 4,25
- 5,80
- 6,80
- 8,60
- 9,90
- 11,40
- 13,40
- 16,35

1,30
1,42
1,63
1,85
2,05
2,30
2,85
3,50
4,15
5,80
6,80
8,60
9,90
11,40
13,40
16,53

- 1,50
- 1,63
- 1,83
- 2,05
- 2,25
- 2,50
- 3,05
- 3,70
- 4,45
- 6,10
- 7,10
- 8,90
- 10,30
- 11,80
- 13,80
- 16,85

Specification:
1 = PTFE Typ ET (250V)
2 = PTFE Typ E (600V)
3 = PTFE Typ EE (1000V)
4 = FEP Typ KT (250V)
5 = FEP Typ K (600V)
6 = FEP Typ KK (1000V)

Conductor:
1 = Cu silver-plated
2 = Cu nickel-plated
3 = Cu tinned
4 = Cu bare
Colour:
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

ConCab kabel connects the world

10 green
11 beige
50 transparent
99 green/yellow

451

CC-singlecoreFEP/PTFE-345
(AWGdimension)
ConformstotheEClowvoltageguideline73/23/EEC

Technicaldata
Ratedvoltage:
as listed in table
Testvoltage:
as listed in table

The CC- single core FEP/PTFE-345


can be used in many areas where extreme
temperatures occur. It is exceptionally stable to oil,
fat, acid, alkali and solvents. Furthermore FEP/PTFE
insulated cores are sun and weather resistant.

Conductorstranding:
fine copper strands acc. to AWG
depending on temperature range bare,
tinned, silver-plated or nickel-plated
Conductormaterial:
bare: +130C
tinned: +180C
silver-plated: +200C
nickel-plated: +260C

Construction
FEP:
Bare, tinned, silver-plated or nickel-plated strands of
copper wire, FEP core insulation,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
PTFE:
Bare, tinned, silver-plated or nickel-plated strands of
copper wire, PTFE core
insulation, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).

452

Insulationresistance:
min. 1 GOhm X km
FEP:
short-term:
PTFE:
short-term:

ConCab kabel connects the world

Temperaturerange:
-100C to +200C
+230C
-200C to +260C
+300C
Bendingradius:
10 X core diameter
Approvals:
acc. to MIL-W 16878

Part-No.

345 387.
345 367.
345 347.
345 327.
345 321.
345 307.
345 301.
345 287.
345 281.
345 267.
345 261.
345 247.
345 241.
345 227.
345 221.
345 207.
345 201.
345 187.
345 181.
345 160.
345 140.
345 120.
345 100.
345 080.
345 060.
345 040.
345 020.
345 010.
345 000.
345 001.
345 002.

AWG

...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

38/7
36/7
34/7
32/7
32/19
30/7
30/19
28/7
28/19
26/7
26/19
24/7
24/19
22/7
22/19
20/7
20/19
18/7
18/19
16
14
12
10
8
6
4
2
1
0
00
0000

Cross-section Conductor
stranding
X x
mm
mm2
0,009
0,014
0,022
0,034
0,035
0,057
0,059
0,089
0,090
0,141
0,155
0,227
0,241
0,355
0,382
0,563
0,616
0,897
0,963
1,229
1,941
3,085
4,743
8,307
13,589
21,594
33,696
42,361
53,914
67,038
106,764

7 X 0,040
7 X 0,051
7 X 0,064
7 X 0,080
19 X 0,051
7 X 0,102
19 X 0,064
7 X 0,127
19 X 0,080
7 X 0,160
19 X 0,102
7 X 0,203
19 X 0,127
7 X 0,254
19 X 0,160
7 X 0,320
19 X 0,203
7 X 0,404
19 X 0,254
19 X 0,287
19 X 0,361
19 X 0,455
37 X 0,404
133 X 0,282
133 X 0,361
133 X 0,455
665 X 0,254
836 X 0,254
1064 X 0,254
1323 X 0,254
2107 X 0,254

PleasecompletethePart-No.345....
whenorderingwiththefollowingspecifications:
Refertopartslist

345-

Cross-section
Specification
Conductor
Colour
Example:
3451813 100 =PTFEAWG18/19,1000V,
Cu-silver-plated,Colourblack

Corediametermm(min.-max.)
Ratedvoltage250V
Ratedvoltage600V Ratedvoltage1000V
Testvoltage2500V
Testvoltage3400V
Testvoltage 5000V
ET/KT
E/K
EE/KK
0,33 - 0,48
0,36 - 0,51
0,38 - 0,53
0,48 - 0,58
0,48 - 0,58
0,56 - 0,66
0,56 - 0,66
0,64 - 0,74
0,64 - 0,74
0,74 - 0,84
0,74 - 0,84
0,86 - 0,97
0,86 - 0,97
1,02 - 1,12
1,02 - 1,12
1,22 - 1,32
1,22 - 1,32

0,56 - 0,71
0,61 - 0,81
0,64 - 0,84
0,64 - 0,84
0,71 - 0,91
0,71 - 0,91
0,79 - 0,99
0,79 - 0,99
0,89 - 1,09
0,89 - 1,09
1,02 - 1,22
1,02 - 1,22
1,17 - 1,37
1,17 - 1,37
1,37 - 1,58
1,37 - 1,58
1,63 - 1,88
1,63 - 1,88
1,85 - 2,21
2,21 - 2,66
2,69 - 3,05
3,23 - 3,58

Specification:
1 = PTFE Typ ET (250V)
2 = PTFE Typ E (600V)
3 = PTFE Typ EE (1000V)
4 = FEP Typ KT (250V)
5 = FEP Typ K (600V)
6 = FEP Typ KK (1000V)
Colours:
00 black
01 blue
02 brown
03 red
04 white

05 grey
06 violet
07 pink
08 orange
09 yellow

ConCab kabel connects the world

0,89 - 1,09
0,89 - 1,09
0,97 - 1,17
0,97 - 1,17
1,04 - 1,25
1,04 - 1,25
1,14 - 1,35
1,14 - 1,35
1,27 - 1,47
1,27 - 1,47
1,42 - 1,63
1,42 - 1,63
1,63 - 1,83
1,63 - 1,83
1,88 - 2,13
1,88 - 2,13
2,11 - 2,14
2,46 - 2,87
2,95 - 3,35
3,85 - 3,89
5,00 - 5,51
7,19 - 7,67
8,79 - 9,30
10,45 - 11,05
11,89 - 12,40
13,16 - 13,67
14,61 - 15,22
18,01 - 18,62

Conductor:
1 = Cu silver-plated
2 = Cu nickel-plated
3 = Cu tinned
4 = Cu bare

10 green
11 beige
50 transparent
99 green/yellow

453

CC-multicorecableFEP-639
Excellenttemperaturestability
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 639 4G1,5 FEP

Technicaldata
Ratedvoltage:
600 V
Testvoltage:
2500 V

The CC-multi core cable FEP-639 is used in many


areas where extreme temperatures occur and is
exceptionally stable to oil, fat, acid, alkali and
solvents. Furthermore FEP flexible cables are sun and
weather resistant.

Conductorstranding:
fine copper strands
acc. to DIN VDE 0295, class 5
depending on temperature range bare,
tinned or silver-plated

Construction
Bare, tinned or silver-plated strands of copper wire,
FEP core insulation, core colours acc. to DIN VDE
0293, part 308, 6 cores and more black with white
numbering and green/yellow protective conductor in
the outer layer. FEP outer sheath, flame retardant and
self-extinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1 and IEC 60332-1).
Colour black.
Other colours available on request.

454

ConCab kabel connects the world

Conductormaterial:
bare: +130C
tinned: +180C
silver-plated: +200C
Insulationresistance:
min. 1 GOhm X km
Temperaturerange:
-100C to +200C
short-term: +230C
Bendingradius:
15 X cable diameter

Part-No.

No.ofcores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

639 002 02 ..
639 002 03 ..
639 002 04 ..
639 002 05 ..

2 X 0,25
3 G 0,25
4 G 0,25
5 G 0,25

5,0
7,5
10,0
12,5

3,2
3,4
3,7
4,1

18
23
27
34

639 005 02 ..
639 005 03 ..
639 005 04 ..
639 005 05 ..

2 X 0,5
3 G 0,5
4 G 0,5
5 G 0,5

9,8
14,7
19,6
24,5

3,8
4,0
4,5
5,1

21
32
44
50

639 007 02 ..
639 007 03 ..
639 007 04 ..
639 007 05 ..

2 X 0,75
3 G 0,75
4 G 0,75
5 G 0,75

14,4
21,6
29,0
36,0

4,5
4,8
5,2
5,8

31
46
58
69

639 010 02 ..
639 010 03 ..
639 010 04 ..
639 010 05 ..

2 X 1,0
3 G 1,0
4 G 1,0
5 G 1,0

19,2
29,0
38,4
48,0

4,9
5,2
5,7
6,1

42
55
70
89

639 015 02 ..
639 015 03 ..
639 015 04 ..
639 015 05 ..
639 015 07 ..
639 015 12 ..

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0

5,4
5,8
6,3
7,1
7,8
10,6

53
70
98
117
184
310

Part-No.

kg/km

No.ofcores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

kg/km

639 025 02 ..
639 025 03 ..
639 025 04 ..
639 025 05 ..
639 025 07 ..

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

48,0
72,0
96,0
120,0
168,0

6,5
7,2
7,8
8,6
9,7

75
120
182
205
260

639 040 02 ..
639 040 03 ..
639 040 04 ..
639 040 05 ..

2X4
3G4
4G4
5G4

77,0
115,2
154,0
192,0

8,0
8,6
9,7
10,7

129
172
215
270

639 060 02 ..
639 060 03 ..
639 060 04 ..

2X6
3G6
4G6

115,2
173,0
230,0

9,5
10,2
11,2

210
285
340

PleasecompletethePart-No.639....
whenorderingwiththefollowingspecifications:
639 010

Conductor:
1 = Cu silver-plated
2 = Cu nickel-plated
3 = Cu tinned
4 = Cu bare

Refer to parts list


Cross-section
Core amount
Type of conductor
Sheath colours

Example:
639 010 0410 = 4 G 1,0 Cu silver-plated, colour black

Sheathcolours:
0 = black
1 = blue
2 = brown
3 = red
4 = white
5 = grey

ConCab kabel connects the world

455

CC-multicorecablePTFE-640
Excellenttemperaturestability
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 640 4G1,5 PTFE

Technicaldata
Ratedvoltage:
600 V
Testvoltage:
2500 V

The CC-multi core cable PTFE-640 is used in many


areas where extreme temperatures occur and is
exceptionally stable to oil, fat, acid, alkali and
solvents. Furthermore PTFE flexible cables are sun
and weather resistant.

Conductorstranding:
fine copper strands
acc. to DIN VDE 0295, class 5
depending on temperature range
bare, tinned, silver-plated, or nickel-plated

Construction
Bare, tinned, silver-plated or nickel-plated strands of
copper wire, PTFE core insulation, core colours acc.
to DIN VDE 0293, part 308, 6 cores or more black
with white numbering and green/yellow protective
conductor in the outer layer.
PTFE outer sheath, flame retardant and self-extinguishing (acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour black.
Other colours available on request.

456

ConCab kabel connects the world

Conductormaterial:
bare: +130C
tinned: +180C
silver-plated: +200C
nickel-plated: +260C
Insulationresistance:
min. 1 GOhm X km
Temperaturerange:
-200C to +260C
short-term:+300C
Bendingradius:
15 X cable diameter

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

640 007 02 ..
640 007 03 ..
640 007 05 ..

2 X 0,75
3 G 0,75
5 G 0,75

14,4
21,6
36,0

4,5
4,8
5,8

31
46
69

640 010 02 ..
640 010 03 ..
640 010 04 ..

2 X 1,0
3 G 1,0
4 G 1,0

19,2
29,0
38,4

4,9
5,2
5,7

42
55
70

640 015 02 ..
640 015 03 ..
640 015 04 ..
640 015 05 ..
640 015 07 ..
640 015 12 ..

2 X 1,5
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5

29,0
43,0
58,0
72,0
101,0
173,0

5,4
5,8
6,3
7,1
7,8
10,6

53
70
98
117
184
310

640 025 02 ..
640 025 03 ..
640 025 04 ..
640 025 05 ..
640 025 07 ..

2 X 2,5
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

48,0
72,0
96,0
120,0
168,0

6,5
7,2
7,8
8,6
9,7

75
120
182
205
260

640 040 02 ..
640 040 03 ..
640 040 04 ..
640 040 05 ..

2X4
3G4
4G4
5G4

77,0
115,2
154,0
192,0

8,0
8,6
9,7
10,7

129
172
215
270

640 060 02 ..
640 060 03 ..
640 060 04 ..

2X6
3G6
4G6

115,2
173,0
230,0

9,5
10,2
11,2

210
285
340

PleasecompletethePart-No.640....
whenorderingwiththefollowingspecifications:
640 010
Refer to parts list
Cross-section
Core amount
Type of conductor
Sheath colours

Conductor:
colours:
1 = Cu silver-plated
2 = Cu nickel-plated
3 = Cu tinned
4 = Cu bare

Sheath
0 = black
1 = blue
2 = brown
3 = red
4 = white
5 = grey

Example:
640 010 03 3 0 = 3 G 1,0 Cu tinned, colour black

ConCab kabel connects the world

457

CC-Nonflamsinglecore-329
Excellenttemperaturestabilityupto450C
ConformstotheEClowvoltageguideline73/23/EEC

The CC-Nonflam single core-329 is excellent for


wiring equipment in areas with extremely high
temperatures. This is necessary in the installation of
radiators, household heating appliances as well as in
heavy industries like foundries, steel melting furnaces,
glass production and in all other kinds of steel works.

Construction
Fine strands of nickel wires, multilayered fibre glass
insulation covered with mineral impregnated braiding.
Colour grey.
Other colours are available on request

Part-No.

Crosssection

Outer
diameter
approx.
mm

Weight
kg/ km

Technicaldata

Purenickelstrands
329 0002 05
329 0005 05
329 0007 05
329 0010 05
329 0015 05
329 0025 05
329 0040 05
329 0060 05
329 0100 05
329 0160 05
329 0250 05
329 0350 05
329 0500 05

458

0,25
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0

2,2
2,5
2,7
3,2
3,4
4,0
4,5
5,3
8,0
9,4
10,6
13,4
14,0

6,5
8,7
11,9
14,5
20,5
32,2
50,1
72,3
130,0
206,0
323,0
423,0
590,0

ConCab kabel connects the world

Ratedvoltage:
300/500 V
Testvoltage:
2000 V
Conductorstranding:
fine strands of pure nickel
Temperaturerange:
-60C to +450C
short-term: +600C

CC-Nonflamsinglecore-328
Excellenttemperaturestabilityupto1400C
ConformstotheEClowvoltageguideline73/23/EEC

The CC-Nonflam single core-328 is excellent


for wiring equipment in areas with extremely
high temperatures up to 1400 C (peak).
This is necessary in the installation of
electric circuits in high-risk environments as
well as in heavy industries like foundries,
steel melting furnaces, glass production and
in all other kinds of steel works.
.

Construction
Fine strands of nickel wires,
multilayered fibre glass insulation covered
with mineral impregnated borosilicoaluminate fibre braiding.
Colour white.
Optional stainless steel outer braiding.

Part-No.

Crosssection

Outer
diameter
approx.
mm

Weight
kg/ km

Technicaldata
Ratedvoltage:
up to 600/1000 V

Purenickelstrands
328 0005 03
328 0007 03
328 0010 03
328 0015 03
328 0025 03
328 0040 03
328 0060 03
328 0100 03
328 0160 03
328 0250 03
328 0350 03
328 0500 03

0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0

2,4
2,7
2,9
3,3
4,0
4,5
5,3
8,0
9,3
10,6
13,4
14,2

12,0
16,0
19,5
26,5
37,5
55,0
82,0
150,0
240,0
372,0
468,0
674,0

Testvoltage:
2500 V
Conductorstranding:
fine-multistranded nickeled copper wires or
fine-multistranded pure nickel wire

ConCab kabel connects the world

Temperaturerange:
-150C to +1100C
short-term: +1400C

459

CC-Nonflammulticorecable-629
Excellenttemperaturestabilityupto450C
ConformstotheEClowvoltageguideline73/23/EEC

The CC-Nonflam multi core cable-629 is excellent for


cabling equipment in areas with extremely high
temperatures. This is necessary in the installation of
radiators, household heating appliances as well as in
heavy industries like foundries, steel melting furnaces,
glass production and in all other kinds of steel works.

Construction
Fine strands of nickel-plated copper wire or pure
nickel wires, multilayered fibre glass insulation
covered with mineral impregnated braiding, cores
twisted in layers. Sheath impregnated mineral
fibre braiding. Colour grey.
Other colours are available on request.

460

ConCab kabel connects the world

Technicaldata
Ratedvoltage:
300/500 V
Testvoltage:
2000 V
Conductorstranding:
fine nickel-plated copper or
fine pure nickel strands
Temperaturerange:
-60C to +450C
short-term: +600C

Part-No.

No. of
cores
+
crosssection

Copper

Outer
diameter
approx.

Weight

kg /km

mm

kg/km

Nickel-plated copper strands

Part-No.

No. of
cores
+
crosssection

Outer
diameter
approx.

Weight

mm

kg/ km

Pure nickel strands

629 0005 002 0


629 0005 003 0
629 0005 004 0
629 0005 005 0
629 0005 006 0
629 0005 007 0

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
6 X 0,5
7 X 0,5

9,6
14,4
19,2
24,0
28,8
34,0

6,2
6,4
7,4
8,1
8,4
8,7

44
50
66
78
92
98

629 0005 002 1


629 0005 003 1
629 0005 004 1
629 0005 005 1
629 0005 006 1
629 0005 007 1

2 X 0,5
3 X 0,5
4 X 0,5
5 X 0,5
6 X 0,5
7 X 0,5

6,2
6,4
7,4
8,1
8,4
8,7

44
50
66
78
92
98

629 0007 002 0


629 0007 003 0
629 0007 004 0
629 0007 005 0
629 0007 006 0
629 0007 007 0

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
6 X 0,75
7 X 0,75

14,4
21,6
29,0
36,0
43,2
50,0

6,7
7,1
8,1
8,8
9,5
9,5

51
62
80
97
112
120

629 0007 002 1


629 0007 003 1
629 0007 004 1
629 0007 005 1
629 0007 006 1
629 0007 007 1

2 X 0,75
3 X 0,75
4 X 0,75
5 X 0,75
6 X 0,75
7 X 0,75

6,7
7,1
8,1
8,8
9,5
9,5

51
62
80
97
112
120

629 0010 002 0


629 0010 003 0
629 0010 004 0
629 0010 005 0
629 0010 006 0
629 0010 007 0

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0

19,2
29,0
38,4
48,0
57,6
67,0

6,9
7,7
8,3
9,1
9,8
9,8

58
72
90
106
123
132

629 0010 002 1


629 0010 003 1
629 0010 004 1
629 0010 005 1
629 0010 006 1
629 0010 007 1

2 X 1,0
3 X 1,0
4 X 1,0
5 X 1,0
6 X 1,0
7 X 1,0

6,9
7,7
8,3
9,1
9,8
9,8

58
72
90
106
123
132

629 0015 002 0


629 0015 003 0
629 0015 004 0
629 0015 005 0
629 0015 006 0
629 0015 007 0

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

29,0
43,0
58,0
72,0
87,0
101,0

7,9
8,3
9,1
9,9
10,7
10,7

79
94
119
141
166
180

629 0015 002 1


629 0015 003 1
629 0015 004 1
629 0015 005 1
629 0015 006 1
629 0015 007 1

2 X 1,5
3 X 1,5
4 X 1,5
5 X 1,5
6 X 1,5
7 X 1,5

7,9
8,3
9,1
9,9
10,7
10,7

79
94
119
141
166
180

629 0025 002 0


629 0025 003 0
629 0025 004 0
629 0025 005 0
629 0025 006 0
629 0025 007 0

2 X 2,5
3 X 2,5
4 X 2,5
5 X 2,5
6 X 2,5
7 X 2,5

48,0
72,0
96,0
120,0
144,0
168,0

9,2
9,7
10,6
11,6
12,6
12,6

112
125
161
195
231
266

629 0025 002 1


629 0025 003 1
629 0025 004 1
629 0025 005 1
629 0025 006 1
629 0025 007 1

2 X 2,5
3 X 2,5
4 X 2,5
5 X 2,5
6 X 2,5
7 X 2,5

9,2
9,7
10,6
11,6
12,6
12,6

112
125
161
195
231
266

ConCab kabel connects the world

461

CC-Nonflam multi core cable-628


Halogen-free excellent temperature stabilityup to1400C
Conforms tothe EC low voltage guideline 73/23/EEC

The CC-Nonflam multi core cable-628 is excellent for


cabling equipment in areas with extremely high
temperatures up to 1400C (peak). This is necessary
in the installation of electric circuits in high-risk
environments as well as in heavy industries like
foundries, steel melting furnaces, glass production and
in all other kinds of steel works.

Construction
Fine strands of nickel wires, multilayered fibre glass
insulation covered with mineral impregnated
borosilico-aluminate fibre braiding, cores twisted in
layers. Sheath out of impregnated mineral fibre
braiding. Colour grey.
Optional stainless steel outer shielding.

462

ConCab kabel connects the world

Technical data
Rated voltage:
up to 600/1000 V
Test voltage:
2500 V
Conductor stranding:
fine strands of pure nickel
Temperature range:
-150C to +1100C
short-term: +1400C

463

CC-powercableNYY-J-802
0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 802 5G1,5 NYY-J

Technicaldata
Ratedvoltage:
0,6/1 kV
The CC-power cable NYY-J-802 is designed to be
laid in power supply networks over, on, inside and
under plaster in dry, damp and wet rooms as well as
in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable is suitable to be laid in water and
underground. It is stable to UV radiation.

Testvoltage:
4000 V
Conductorstranding:
single or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2
Insulationresistance:
min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper wires, PVC
core insulation, core colours acc. to DIN VDE 0293,
part 308, 3 cores or more with green/yellow protective
conductor in the outer layer, cores twisted in layers.
PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1). Colour black.

464

fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
12 X cable diameter

Approvals:
acc. to DIN VDE 0276, part 603

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

kg/km

No.ofcores
+
crosssection

Copper Outer Weight


weight diameter
approx.
kg/km
mm kg / km

aNYY-J

NYY-J
802 0015 003
802 0015 004
802 0015 005
802 0015 007
802 0015 010
802 0015 012
802 0015 014
802 0015 016
802 0015 019
802 0015 021
802 0015 024
802 0015 030
802 0015 040
802 0015 052
802 0015 061

3 G 1,5 RE
4 G 1,5 RE
5 G 1,5 RE
7 G 1,5 RE
10 G 1,5 RE
12 G 1,5 RE
14 G 1,5 RE
16 G 1,5 RE
19 G 1,5 RE
21 G 1,5 RE
24 G 1,5 RE
30 G 1,5 RE
40 G 1,5 RE
52 G 1,5 RE
61 G 1,5 RE

43,0
58,0
72,0
101,0
144,0
173,0
202,0
230,0
274,0
302,0
346,0
432,0
576,0
749,0
878,0

12,0
13,0
14,0
15,0
18,0
19,0
20,0
21,0
22,0
22,0
24,0
26,0
28,0
31,0
33,0

230
260
300
360
520
560
620
690
760
830
950
1100
1350
1450
1680

802 0025 003


802 0025 004
802 0025 005
802 0025 007
802 0025 010
802 0025 012
802 0025 014
802 0025 016
802 0025 019
802 0025 021
802 0025 024
802 0025 030
802 0025 040
802 0025 052

3 G 2,5 RE
4 G 2,5 RE
5 G 2,5 RE
7 G 2,5 RE
10 G 2,5 RE
12 G 2,5 RE
14 G 2,5 RE
16 G 2,5 RE
19 G 2,5 RE
21 G 2,5 RE
24 G 2,5 RE
30 G 2,5 RE
40 G 2,5 RE
52 G 2,5 RE

72,0
96,0
120,0
168,0
240,0
288,0
336,0
384,0
456,0
504,0
576,0
720,0
960,0
1248,0

13,0
14,0
15,0
16,0
20,0
20,0
21,0
22,0
23,0
24,0
26,0
28,0
31,0
35,0

280
320
365
450
630
680
790
870
990
1050
1400
1450
1800
2250

802 0040 003


802 0040 004
802 0040 005
802 0040 007

3 G 4 RE
4 G 4 RE
5 G 4 RE
7 G 4 RE

115,0
154,0
192,0
269,0

16,0
17,0
18,0
19,0

410
480
550
670

802 0060 003


802 0060 004
802 0060 005
802 0060 007

3 G 6 RE
4 G 6 RE
5 G 6 RE
7 G 6 RE

173,0
230,0
288,0
403,0

16,0
18,0
19,0
21,0

460
590
680
850

802 0100 001


802 0100 003
802 0100 004
802 0100 005
802 0100 007

1 G 10 RE
3 G 10 RE
4 G 10 RE
5 G 10 RE
7 G 10 RE

96,0
288,0
384,0
480,0
672,0

9,0
18,0
20,0
21,0
23,0

190
660
790
930
1200

802 0160 001


802 0160 003

1 G 16 RE
3 G 16 RE

154,0
461,0

10,0
20,0

260
900

ConductormarkingsRE,RM,SMrefertotechnicalappendix

802 0160 004 4 G 16 RE


802 0160 005 5 G 16 RE

614,0
768,0

22,0
24,0

1100
1300

802 0250 001


802 0250 003
803 0250 003
802 0250 004
802 0250 005

1 G 25 RM
3 G 25 RM
3 G 25 RM/16 RE
4 G 25 RM
5 G 25 RM

240,0
720,0
874,0
960,0
1200,0

13,0
26,0
26,0
27,0
30,0

380
1350
1450
1650
2050

802 0350 001


802 0350 003
803 0350 003
802 0350 004
802 0350 005

1 G 35 RM
3 G 35 SM
3 G 35 SM/16 RE
4 G 35 RM
5 G 35 RM

336,0
1008,0
1162,0
1344,0
1680,0

14,0
23,0
26,0
30,0
32,0

490
1350
1750
2160
2600

802 0500 001


802 0500 003
803 0500 003
802 0500 004

1 G 50 RM
3 G 50 SM
3 G 50 SM/25 RM
4 G 50 SM

480,0
1440,0
1680,0
1920,0

15,0
26,0
31,0
30,0

650
1800
2350
2450

802 0700 001


802 0700 003
803 0700 003
802 0700 004

1 G 70 RM
3 G 70 SM
3 G 70 SM/35 SM
4 G 70 SM

672,0
2016,0
2352,0
2688,0

16,0
30,0
32,0
33,0

860
2450
2900
3250

802 0950 001


802 0950 003
803 0950 003
802 0950 004

1 G 95 RM
3 G 95 SM
3 G 95 SM/50 SM
4 G 95 SM

912,0
2736,0
3216,0
3648,0

19,0
34,0
37,0
38,0

1150
3350
3900
4400

802 1200 001


802 1200 003
803 1200 003
802 1200 004

1 G 120 RM
3 G 120 SM
3 G 120 SM/70 SM
4 G 120 SM

1152,0
3456,0
4128,0
4608,0

20,0
36,0
40,0
42,0

1400
4100
4900
5450

802 1500 001


802 1500 003
803 1500 003
802 1500 004

1 G 150 RM
3 G 150 SM
3 G 150 SM/70 SM
4 G 150 SM

1440,0
4320,0
4992,0
5760,0

22,0
40,0
44,0
47,0

1700
5000
5800
6550

802 1850 001


802 1850 003
803 1850 003
802 1850 004

1 G 185 RM
3 G 185 SM
3 G 185 SM/95 SM
4 G 185 SM

1776,0
5328,0
6240,0
7104,0

24,0
45,0
49,0
51,0

2100
6250
7300
8200

802 2400 001


802 2400 003
803 2400 003
802 2400 004

1 G 240 RM
3 G 240 SM
3 G 240 SM/120 SM
4 G 240 SM

2306,0
6912,0
8064,0
9216,0

27,0
51,0
55,0
58,0

2650
8050
9400
10650

465

CC-powercableNYY-O-804
0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 804 5x1,5 NYY-O

Technicaldata
Ratedvoltage:
0,6/1 kV
The CC-power cable NYY-O-804 is designed
to be laid in power supply networks over, on, inside
and under plaster in dry, damp and wet rooms as well
as in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable is suitable to be laid in water and
underground. It is stable to UV radiation.

Testvoltage:
4000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2
Insulationresistance:
min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper,
PVC core insulation, core colours
acc. to DIN VDE 0293, part 308, cores twisted in
layers. PVC outer sheath, flame retardant and selfextinguishing (acc. to DIN VDE 0482, part 265-2-1
resp. EN 50265-2-1 and IEC 60332-1).
Colour black.

466

fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
12 X cable diameter

Approvals:
acc. to DIN VDE 0276, part 603

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/km

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg / km

NYY-O

NYY-O
804 0015 002
804 0015 003
804 0015 004
804 0015 005
804 0015 007

2 X 1,5 RE
3 X 1,5 RE
4 X 1,5 RE
5 X 1,5 RE
7 X 1,5 RE

29,0
43,0
60,0
72,0
101,0

12,0
12,0
13,0
14,0
15,0

180
200
240
270
360

804 0350 001 1 X 35 RM


804 0350 004 4 X 35 SM

336,0
1344,0

14,0
30,0

490
2160

804 0500 001 1 X 50 RM


804 0500 004 4 X 50 SM

480,0
1920,0

15,0
30,0

650
2350

804 0025 002


804 0025 003
804 0025 004
804 0025 005

2 X 2,5 RE
3 X 2,5 RE
4 X 2,5 RE
5 X 2,5 RE

48,0
72,0
98,0
120,0

12,0
13,0
14,0
15,0

250
265
295
360

804 0700 001 1 X 70 RM


804 0700 004 4 X 70 SM

672,0
2688,0

16,0
33,0

860
3250

804 0950 001 1 X 95 RM


804 0950 004 4 X 95 SM

912,0
3648,0

19,0
38,0

1150
4400

804 0040 001


804 0040 002
804 0040 003
804 0040 004

1 X 4 RE
2 X 4 RE
3 X 4 RE
4 X 4 RE

38,0
77,0
115,0
154,0

8,0
15,0
15,0
17,0

120
325
360
480

804 1200 001 1 X 120 RM


804 1200 004 4 X 120 SM

1152,0
4608,0

20,0
42,0

1400
5450

804 0060 001


804 0060 002
804 0060 003
804 0060 004

1 X 6 RE
2 X 6 RE
3 X 6 RE
4 X 6 RE

58,0
115,0
174,0
230,0

9,0
15,0
16,0
18,0

155
400
435
590

804 1500 001 1 X 150 RM


804 1500 004 4 X 150 SM

1440,0
5760,0

22,0
47,0

1700
6550

804 1850 001 1 X 185 RM


804 1850 004 4 X 185 SM

1776,0
7110,0

24,0
53,0

2100
9050

804 0100 001


804 0100 002
804 0100 003
804 0100 004

1 X 10 RE
2 X 10 RE
3 X 10 RE
4 X 10 RE

96,0
192,0
288,0
384,0

10,0
17,0
18,0
20,0

190
485
560
790

804 2400 001 1 X 240 RM


804 2400 004 4 X 240 SM

2304,0
9220,0

27,0
60,0

2650
11380

804 3000 001 1 X 300 RM

2880,0

30,0

3300

804 0160 001


804 0160 002
804 0160 003
804 0160 004

1 X 16 RE
2 X 16 RE
3 X 16 RE
4 X 16 RE

154,0
307,0
462,0
614,0

10,0
19,0
20,0
22,0

260
750
820
1100

804 4000 001 1 X 400 RM

3840,0

35,0

4200

804 5000 001 1 X 500 RM

4800,0

38,0

5200

804 0250 001


804 0250 002
804 0250 004

1 X 25 RM
2 X 25 RM
4 X 25 RM

240,0
480,0
960,0

13,0
24,0
27,0

380
1150
1650

ConductormarkingsRE,RM,SMrefertotechnicalappendix

ConCab kabel connects the world

467

CC-powercableNYCY-820
0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 820 3x1,5/1,5 NYCY

The CC-power cable NYCY-820 is designed to be


laid in power supply networks over, on, inside and
under plaster in dry, damp and wet rooms as well as
in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable is suitable to be laid in water. It is stable to
UV radiation. Furthermore, this cable is ideal to be
used where increased mechanical protection is
required resp. protection against touch voltage. The
concentric copper conductor serves as a shield and
can be used as a neutral conductor (N) or protective
conductor (PE/PEN) but not as an outside conductor.

Technicaldata
Ratedvoltage:
0,6/1 kV
Testvoltage:
4000 V
Conductorstranding:
solid copper wire
acc. to DIN VDE 0295, class 1
Insulationresistance:
min. 100 MOhm X km

Construction
Solid bare copper wire, PVC core insulation, core
colours acc. to DIN VDE 0293, part 308, cores
twisted in layers. PVC filling inner sheath, concentric
bare copper shield and copper tape PVC outer sheath,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN50265-2-1 and IEC 60332-1).
Colour black.

468

fixed installation:

Temperaturerange:
-40C to +70C

Bendingradius:
fixed installation: 12 X cable diameter
Approvals:
acc. to DIN VDE 0276, part 603

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

820 0015 002


820 0015 003
820 0015 004
820 0015 007
820 0015 010
820 0015 012
820 0015 014
820 0015 019
820 0015 024
820 0015 030
820 0015 040

2 X 1,5 RE/1,5
3 X 1,5 RE/1,5
4 X 1,5 RE/1,5
7 X 1,5 RE/2,5
10 X 1,5 RE/2,5
12 X 1,5 RE/2,5
14 X 1,5 RE/2,5
19 X 1,5 RE/4
24 X 1,5 RE/6
30 X 1,5 RE/6
40 X 1,5 RE/10

52,0
66,0
81,0
133,0
176,0
205,0
235,0
320,0
415,0
500,0
696,0

13,0
14,0
15,0
17,0
19,0
20,0
21,0
23,0
26,0
27,0
30,0

245
290
330
440
550
620
680
840
1030
1180
1500

820 0025 002


820 0025 003
820 0025 004
820 0025 007
820 0025 010
820 0025 012
820 0025 014
820 0025 019
820 0025 024
820 0025 030
820 0025 040

2 X 2,5 RE/2,5
80,0
3 X 2,5 RE/2,5 105,0
4 X 2,5 RE/2,5 128,0
7 X 2,5 RE/2,5 200,0
10 X 2,5 RE/4
286,0
12 X 2,5 RE/4
334,0
14 X 2,5 RE/6
403,0
19 X 2,5 RE/6
523,0
24 X 2,5 RE/10 696,0
30 X 2,5 RE/10 840,0
40 X 2,5 RE/10 1080,0

14,0
15,0
16,0
18,0
21,0
22,0
23,0
25,0
28,0
30,0
33,0

310
350
410
540
730
800
900
1090
1370
1580
1970

820 0040 003


820 0040 004

3 X 4 RE/4
4 X 4 RE/4

161,0
200,0

16,0
18,0

480
550

820 0060 003


820 0060 004

3 X 6 RE/6
4 X 6 RE/6

240,0
297,0

18,0
19,0

590
690

ConductormarkingsRE,RM,SMrefertotechnicalappendix

ConCab kabel connects the world

469

CC-powercableNYCWY-810
0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 810 2x10/10 NYCWY

The CC-power cable NYCWY-810 is designed to be


laid in power supply networks over, on, inside and
under plaster in dry, damp and wet rooms as well as
in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable is suitable to be laid under water. It is
stable to UV radiation. Furthermore, this cable is ideal
to be used where increased mechanical protection is
required resp. protection against touch voltage. The
concentric ceander-copper conductor serves as a
shield and can be used as a neutral conductor (N) or
protective conductor (PE/PEN) but not as an
outside conductor.

Technicaldata
Ratedvoltage:
0,6/1 kV
Testvoltage:
4000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1
Insulationresistance:
min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper wire, PVC
core insulation, core colours acc. to DIN VDE 0293,
part 308. PVC filling inner sheath, bare concentric
ceander copper wire shield with copper tape PVC
outer sheath, flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN50265-2-1 and IEC 60332-1).
Colour black.

470

fixed installation:

Temperaturerange:
-40C to +70C

Bendingradius:
fixed installation: 12 X cable diameter
Approvals:
acc. to DIN VDE 0276, part 603

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

810 0100 002


810 0100 003
810 0100 004

2 X 10 RE/10
3 X 10 RE/10
4 X 10 RE/10

312,0
408,0
504,0

19,0
20,0
21,0

680
780
910

810 0160 003


810 0160 004

3 X 16 RE/16
4 X 16 RE/16

643,0
796,0

22,0
24,0

1100
1250

810 0250 003


810 0250 004

3 X 25 RM/25
4 X 25 RM/16

1003,0
1142,0

27,0
29,0

1650
1850

810 0350 003 3 X 35 SM/16


810 0350 0031 3 X 35 SM/35
810 0350 004 4 X 35 SM/16

1190,0
1402,0
1526,0

26,0
27,0
29,0

1170
1990
2150

810 0500 003 3 X 50 SM/25


810 0500 0031 3 X 50 SM/50
810 0500 004 4 X 50 SM/25

1723,0
2000,0
2203,0

30,0
31,0
34,0

2300
2500
2950

810 0700 003 3 X 70 SM/35


810 0700 0031 3 X 70 SM/70
810 0700 004 4 X 70 SM/35

2410,0
2796,0
3082,0

34,0
34,0
38,0

3150
3500
3950

810 0950 003 3 X 95 SM/50


810 0950 0031 3 X 95 SM/95
810 0950 004 4 X 95 SM/50

3296,0
3791,0
4208,0

39,0
39,0
43,0

4200
4700
5300

810 1200 004

4 X 120 SM/70 5388,0

47,0

6650

810 1500 004

4 X 150 SM/70 6540,0

51,0

7950

810 1850 004

4 X 185 SM/95 8159,0

57,0

9900

ConductormarkingsRE,RM,SMrefertotechnicalappendix

ConCab kabel connects the world

471

CC-installationcableNYM-J-808
NYM-O-807
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 808 5G2,5 NYM-J

Technicaldata
The CC-installation cable NYM-J-808 and
NYM-O-807 is designed to be laid over,
on, inside and under plaster in dry, damp and wet
rooms as well as in brickwork and in concrete with
the exception of cabling in shaken, vibrated and
compressed concrete. This cable can also be used
outdoors provided it is protected from direct
sunlight.

Ratedvoltage:
300/500 V
Testvoltage:
2000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2

Construction
Bare, solid or multiple strands of copper wire,
PVC based core insulation, core colours acc. to
DIN VDE 0293, part 308. With NYM-J as of
3 cores with green/yellow protective conductor in
the outer layer, cores twisted in layers. PVC outer
sheath, flame retardant and self-extinguishing
(acc.to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Colour grey.

472

Insulationresistance:
min. 20 MOhm X km
fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
6 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 204

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

kg/km

No.ofcores
+
crosssection

NYM-J

kg/km

Outer
diameter
approx.
mm

Weight
kg / km

NYM-O

808 0015 001


1 G 1,5 RE
808 0015 003
3 G 1,5 RE
808 0015 004
4 G 1,5 RE
808 0015 005
5 G 1,5 RE
808 0015 007
7 G 1,5 RE
808 0015 010 10 G 1,5 RM*
808 0015 012 12 G 1,5 RM*

14,4
43,0
58,0
72,0
101,0
144,0
173,0

5,5
8,8
9,6
10,2
11,0
13,3
14,0

47
131
155
182
224
333
423

808 0025 001


808 0025 003
808 0025 004
808 0025 005
808 0025 007

1 G 2,5 RE
3 G 2,5 RE
4 G 2,5 RE
5 G 2,5 RE
7 G 2,5 RE

24,0
72,0
96,0
120,0
168,0

6,0
10,0
11,0
11,7
13,0

61
181
225
259
331

808 0040 001


808 0040 003
808 0040 004
808 0040 005

1 G 4 RE
3 G 4 RE
4 G 4 RE
5 G 4 RE

38,0
115,0
154,0
192,0

6,8
11,7
12,9
14,2

83
258
322
390

808 0060 001


808 0060 003
808 0060 004
808 0060 005

1 G 6 RE
3 G 6 RE
4 G 6 RE
5 G 6 RE

58,0
173,0
230,0
288,0

7,2
13,2
14,5
15,5

107
354
444
518

808 0100 001


808 0100 003
808 0100 004
808 0100 005

1 G 10 RE
3 G 10 RE
4 G 10 RE
5 G 10 RE

96,0
288,0
384,0
480,0

8,5
16,2
17,2
18,9

158
552
656
799

808 0160 001


808 0160 004
808 0160 005

1 G 16 RM
4 G 16 RM
5 G 16 RM

154,0
614,0
768,0

10,0
20,9
23,4

232
1002
1244

808 0250 001


808 0250 004
808 0250 005

1 G 25 RM* 240,0
4 G 25 RM
960,0
5 G 25 RM 1200,0

12,2
26,0
28,8

240
1570
1930

808 0350 004

4 G 35 RM

29,0

2092

1344,0

Copper
weight

807 0015 001


807 0015 002
807 0015 003
807 0015 004
807 0015 007

1 X 1,5 RE
2 X 1,5 RE
3 X 1,5 RE
4 X 1,5 RE
7 X 1,5 RE

14,4
29,0
43,0
58,0
101,0

5,5
8,5
8,8
9,6
11,0

47
119
131
155
224

807 0025 001


807 0025 002
807 0025 003
807 0025 004
807 0025 005
807 0025 007

1 X 2,5 RE
2 X 2,5 RE
3 X 2,5 RE
4 X 2,5 RE
5 X 2,5 RE
7 X 2,5 RE

24,0
48,0
72,0
96,0
120,0
168,0

6,0
9,7
10,0
11,0
11,7
13,0

61
157
181
225
259
331

807 0040 001 1 X 4 RE

38,0

6,8

83

807 0060 001 1 X 6 RE


807 0060 004 4 X 6 RE

58,0
230,0

7,2
14,5

107
444

807 0100 001 1 X 10 RE


807 0100 004 4 X 10 RE

96,0
384,0

8,5
17,2

158
656

807 0160 001 1 X 16 RM


807 0160 004 4 X 16 RM

154,0
614,0

10,0
20,9

232
1002

807 0250 004 4 X 25 RM

960,0

26,0

1570

807 0350 004 4 X 35 RM

1344,0

29,0

2092

*acc.toDINVDE0250,part204
ConductormarkingsRE,RM,SMrefertotechnicalappendix

ConCab kabel connects the world

473

CC-installationcable(N)HMH-J-880
and(N)HMH-O-881
Halogen-free
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 880 5G1,5 (N)HMH-J

The halogen-free CC-installation


cable (N)HMH-J-880 and (N)HMH-O-881 are used
primarily in buildings where a demand for increased
protection for humans and goods is. In the event of
fire it exudes hardly any smoky gases and causes no
corrosion. It is ideal to be laid over, on, inside and
under plaster in dry, damp and wet rooms as well as
in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable can also be used on outside walls
provided it is protected from direct sunlight.

Technicaldata
Ratedvoltage:
300/500 V
Testvoltage:
2000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2
Insulationresistance:
min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper wire,
halogen-free polymer based core insulation acc.
to DIN VDE 0207, core colours acc. to
DIN VDE 0293, part 308. With (N)HMH-J, 3 cores
or more with green/yellow protective conductor in
the outer layer, cores twisted in layers. Outer sheath
flame retardant halogen-free polymer mixture
(acc.to IEC60332-3).
Colour grey.

474

fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
6 X cable diameter

ConCab kabel connects the world

Approvals:
acc. to DIN VDE 0250,
part 215 (design)

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

kg/km

No.ofcores
+
crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

kg / km

(N)HMH-O

(N)HMH-J
880 0015 003
880 0015 004
880 0015 005
880 0015 007

3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5

43,0
58,0
72,0
101,0

8,8
9,6
10,2
11,0

131
155
182
224

880 0025 003


880 0025 004
880 0025 005
880 0025 007

3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5

72,0
96,0
120,0
168,0

10,0
11,0
11,7
13,0

181
225
259
331

880 0040 001


880 0040 003
880 0040 004
880 0040 005

1G4
3G4
4G4
5G4

38,0
115,0
154,0
192,0

6,8
11,7
12,9
14,2

83
258
322
390

880 0060 001


880 0060 003
880 0060 004
880 0060 005

1G6
3G6
4G6
5G6

58,0
173,0
230,0
288,0

7,2
13,2
14,5
15,5

107
354
444
518

880 0100 001


880 0100 003
880 0100 004
880 0100 005

1 G 10
3 G 10
4 G 10
5 G 10

96,0
288,0
384,0
480,0

8,5
16,2
17,2
18,9

158
552
656
799

880 0160 001


880 0160 004
880 0160 005

1 G 16
4 G 16
5 G 16

154,0
614,0
768,0

10,0
20,9
23,4

232
1002
1244

880 0250 004


880 0250 005

4 G 25
5 G 25

960,0
1200,0

26,0
28,8

1570
1930

880 0350 004

4 G 35

1344,0

29,0

2092

881 0015 001


881 0015 002
881 0015 003
881 0015 004
881 0015 007

1 X 1,5
2 X 1,5
3 X 1,5
4 X 1,5
7 X 1,5

14,0
29,0
43,0
58,0
101,0

5,5
8,5
8,8
9,6
11,0

36
84
131
155
224

881 0025 001


881 0025 002
881 0025 003
881 0025 004

1 X 2,5
2 X 2,5
3 X 2,5
4 X 2,5

24,0
48,0
72,0
96,0

6,0
9,7
10,0
11,0

46
112
181
225

881 0040 001


881 0040 002
881 0040 004

1X4
2X4
4X4

38,0
77,0
154,0

6,8
10,0
12,9

83
159
322

881 0060 001


881 0060 002
881 0060 004

1X6
2X6
4X6

58,0
115,0
230,0

7,2
11,5
14,5

107
211
444

881 0100 001


881 0100 002
881 0100 004

1 X 10
2 X 10
4 X 10

96,0
192,0
384,0

8,5
13,7
17,2

158
345
656

881 0160 001


881 0160 004

1 X 16
4 X 16

154,0
614,0

10,0
20,9

232
1002

881 0250 004

4 X 25

960,0

26,0

1570

881 0350 004

4 X 35

1344,0

29,0

2092

ConCab kabel connects the world

475

CC-installationcableNHXMH-J-850
andNHXMH-O-851
Halogen-freewithimprovedbehaviorinfire
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 850 5G1,5 NHXMH-J

The halogen-free CC-installation cable


NHXMH-J-850 and NHXMH-O-851 is
used primarily in buildings where a demand for
increased protection for humans and goods is. In the
event of fire it exudes hardly any smoky gases and
causes no corrosion. It is ideal to be laid over, on,
inside and under plaster in dry, damp and wet rooms
as well as in brickwork and in concrete with the
exception of cabling in shaken, vibrated and
compressed concrete. This cable can also be used
outdoors provided it is protected from
direct sunlight.

Technicaldata
Ratedvoltage:
300/500 V
Testvoltage:
2000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2
Insulationresistance:
min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper wire,
halogen-free cross-linked polymer core insulation,
core colours acc. to DIN VDE 0293, part 308.
NHXMH-J 3 cores or more with green/yellow
protective conductor in the outer layer, cores twisted
in layers. Outer sheath flame retardant halogen-free
polymer mixture (acc. to IEC 60332-3).
Colour grey.

476

fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
6 X cable diameter

Approvals:
acc. to DIN VDE 0250, part 214

ConCab kabel connects the world

Part-No.

No.ofcores Copper
+
weight
crosssection
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

kg/km

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg / km

NHXMH-O

NHXMH-J
850 0015 003
3 G 1,5 RE
850 0015 004
4 G 1,5 RE
850 0015 005
5 G 1,5 RE
850 0015 007
7 G 1,5 RE
850 0015 010 10 G 1,5 RE*
850 0015 012 12 G 1,5 RE*
850 0015 024 24 G 1,5 RE*

43,0
58,0
72,0
101,0
144,0
173,0
346,0

9,1
9,8
10,6
11,0
15,0
15,0
20,0

150
180
200
250
350
400
700

850 0025 003


850 0025 004
850 0025 005
850 0025 007

3 G 2,5 RE
4 G 2,5 RE
5 G 2,5 RE
7 G 2,5 RE

72,0
96,0
120,0
168,0

10,2
10,6
11,5
13,0

180
220
250
350

850 0040 003


850 0040 004
850 0040 005

3 G 4 RE
4 G 4 RE
5 G 4 RE

115,0
154,0
192,0

11,5
13,0
14,3

250
320
380

850 0060 003


850 0060 004
850 0060 005

3 G 6 RE
4 G 6 RE
5 G 6 RE

173,0
230,0
288,0

13,0
14,3
15,5

350
450
550

850 0100 003


850 0100 004
850 0100 005

3 G 10 RE
4 G 10 RE
5 G 10 RE

288,0
384,0
480,0

15,5
16,8
18,3

550
650
800

850 0160 003


850 0160 004
850 0160 005

3 G 16 RM
4 G 16 RM
5 G 16 RM

461,0
615,0
768,0

18,8
20,8
23,0

838
945
1150

850 0250 003


850 0250 004
850 0250 005

3 G 25 RM
4 G 25 RM
5 G 25 RM

720,0
960,0
1200,0

23,3
25,8
28,0

1165
1430
1815

850 0350 003


850 0350 004
850 0350 005

3 G 35 RM
4 G 35 RM
5 G 35 RM

1008,0
1344,0
1680,0

26,0
28,8
30,5

1505
1940
2500

851 0015 001


851 0015 002
851 0015 003
851 0015 004
851 0015 005
851 0015 007

1 X 1,5 RE
2 X 1,5 RE
3 X 1,5 RE
4 X 1,5 RE
5 X 1,5 RE
7 X 1,5 RE

15,0
29,0
43,0
58,0
72,0
101,0

7,0
9,4
10,0
11,0
12,0
12,0

49
120
150
180
200
250

851 0025 001


851 0025 002
851 0025 003
851 0025 004
851 0025 005
851 0025 007

1 X 2,5 RE
2 X 2,5 RE
3 X 2,5 RE
4 X 2,5 RE
5 X 2,5 RE
7 X 2,5 RE

24,0
48,0
72,0
96,0
120,0
168,0

7,6
10,5
10,2
10,6
11,5
13,0

60
150
180
220
250
350

851 0040 001


851 0040 002
851 0040 003
851 0040 004
851 0040 005

1 X 4 RE
2 X 4 RE
3 X 4 RE
4 X 4 RE
5 X 4 RE

39,0
77,0
115,0
154,0
192,0

8,6
11,3
11,5
13,0
14,3

80
200
250
320
380

851 0060 001


851 0060 003
851 0060 004
851 0060 005

1 X 6 RE
3 X 6 RE
4 X 6 RE
5 X 6 RE

58,0
173,0
230,0
288,0

9,9
13,0
14,3
15,5

111
350
450
550

851 0100 001


851 0100 003
851 0100 004
851 0100 005

1 X 10 RE
3 X 10 RE
4 X 10 RE
5 X 10 RE

96,0
288,0
384,0
480,0

11,2
15,5
16,8
18,3

160
550
650
800

851 0160 001


851 0160 003
851 0160 004
851 0160 005

1 X 16 RM
3 X 16 RM
4 X 16 RM
5 X 16 RM

154,0
461,0
615,0
768,0

11,9
18,8
20,8
23,0

232
838
945
1150

ConductormarkingsRE,RM,SMrefertotechnicalappendix
*acc.toVDE0250,part214

ConCab kabel connects the world

477

CC-powercableN2XH-J-856
andN2XH-O-857
Halogen-free,0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 856 5G1,5 N2XH-J

The halogen-free CC-power cable


N2XH-J-856 and N2XH-O-857 is used
primarily in power stations and substations as well as
in buildings where a demand for increased protection
for humans and goods is. In the event of fire it hardly
exudes any smoky gases and causes no corrosion. It is
ideal to be laid over, on, inside and under plaster in
dry, damp and wet rooms as well as in brickwork and
in concrete with the exception of cabling in shaken,
vibrated and compressed concrete. This cable can also
be used outdoors but not in water or buried in ground.

Technicaldata
Ratedvoltage:
0,6/1 kV
Testvoltage:
4000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2

Construction
Bare, solid or multiple strands of copper wire,
halogen-free cross-linked PE core insulation, core
colours acc. to DIN VDE 0293, part 308.
N2XH-J 3 cores or more with green/yellow
protective conductor in the outer layer, cores
twisted in layers. Outer sheath flame
retardant, halogen-free polymer mixture
(acc. to IEC 60332-3).
Colour black.

478

Insulationresistance:
min. 100 MOhm X km
fixed installation:

Temperaturerange:
-40C to +70C

Bendingradius:
fixed installation: 12 X cable diameter
Approvals:
acc. to DIN VDE 0276, part 604

ConCab kabel connects the world

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg/ km

N2XH-J

Part-No.

No.ofcores
+
crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight
kg / km

N2XH-O

856 0015 003 3 G 1,5 RE


856 0015 004 4 G 1,5 RE
856 0015 005 5 G 1,5 RE
856 0015 007 7 G 1,5 RE
856 0015 010 10 G 1,5 RE *
856 0015 012 12 G 1,5 RE *
856 0015 030 30 G 1,5 RE *

43,0
58,0
72,0
101,0
144,0
173,0
432,0

12,4
13,0
14,3
14,6
17,0
18,0
24,0

210
235
273
330
420
460
900

856 0025 003 3 G 2,5 RE


856 0025 004 4 G 2,5 RE
856 0025 005 5 G 2,5 RE
856 0025 007 7 G 2,5 RE
856 0025 010 10 G 2,5 RE *
856 0025 012 12 G 2,5 RE *

72,0
96,0
120,0
168,0
240,0
288,0

13,6
14,1
16,4
16,5
18,0
19,0

260
293
342
435
540
600

856 0040 003


856 0040 004
856 0040 005

3 G 4 RE
4 G 4 RE
5 G 4 RE

115,0
154,0
192,0

14,5
15,1
16,5

335
375
440

856 0060 003


856 0060 004
856 0060 005

3 G 6 RE
4 G 6 RE
5 G 6 RE

173,0
230,0
288,0

15,2
16,2
17,4

856 0100 003


856 0100 004
856 0100 005

3 G 10 RE
4 G 10 RE
5 G 10 RE

288,0
384,0
480,0

856 0160 003


856 0160 004
856 0160 005

3 G 16 RE
4 G 16 RE
5 G 16 RE

856 0250 003


856 0250 004
856 0250 005

857 0015 002 2 X 1,5 RE

29,0

12,0

182

857 0025 002 2 X 2,5 RE

48,0

12,1

218

857 0040 001 1 X 4 RE


857 0040 002 2 X 4 RE

38,0
77,0

8,1
13,2

107
272

857 0060 001 1 X 6 RE


857 0060 002 2 X 6 RE

58,0
115,0

9,0
13,8

129
338

857 0100 001 1 X 10 RE


857 0100 002 2 X 10 RE

96,0
192,0

10,0
16,2

177
452

857 0160 001 1 X 16 RE


857 0160 002 2 X 16 RE

154,0
307,0

10,5
17,5

215
591

857 0250 001 1 X 25 RM


857 0250 002 2 X 25 RM

240,0
480,0

11,8
23,1

322
982

405
475
572

857 0350 001 1 X 35 RM

336,0

13,1

430

857 0500 001 1 X 50 RM

480,0

15,5

588

17,2
17,8
19,5

570
671
805

857 0700 001 1 X 70 RM

672,0

17,2

792

857 0950 001 1 X 95 RM

912,0

19,5

1070

461,0
614,0
768,0

19,5
19,8
22,8

785
932
1180

857 1200 001 1 X 120 RM

1152,0

21,5

1368

857 1500 001 1 X 150 RM

1440,0

23,6

1594

3 G 25 RM
4 G 25 RM
5 G 25 RM

720,0
960,0
1200,0

16,0
23,4
28,0

1204
1440
1710

857 1850 001 1 X 185 RM

1776,0

25,4

2055

857 2400 001 1 X 240 RM

2304,0

28,3

2560

856 0350 003


856 0350 004

3 G 35 RM
4 G 35 RM

1008,0
1344,0

26,0
28,1

1580
1890

857 3000 001 1 X 300 RM

2880,0

31,4

3132

856 0500 003


856 0500 004

3 G 50 RM
4 G 50 RM

1440,0
1820,0

27,8
29,2

1780
2301

856 0700 004

4 G 70 RM

2688,0

32,0

3202

856 0950 004

4 G 95 RM

3648,0

38,0

4230

856 1200 004

4 G 120 RM

4608,0

41,8

5302

ConductormarkingsRE,RM,SMrefertotechnicalappendix
*onrequest,acc.toDINVDE0276,part604

ConCab kabel connects the world

479

CC-powercableN2XCH-858
Halogen-free,0,6/1kV
ConformstotheEClowvoltageguideline73/23/EEC

ConCab kabel Mainhardt 858 3x1,5/1,5 N2XCH

The halogen-free CC power cable N2XCH-858 is


used primarily in power stations and substations as
well as in buildings where a demand for increased
protection for humans and goods is. In the event of
fire it hardly exudes any smoky gases and causes no
corrosion. It is ideal to be laid over, on, inside and
under plaster in dry, damp and wet rooms as well as
in brickwork and in concrete with the exception of
cabling in shaken, vibrated and compressed concrete.
This cable can also be used outdoors provided it is
protected from direct sunlight but not in water or
buried in ground. The concentric copper conductor
serves as a shield and can be used as a neutral
conductor (N) or protective conductor (PE/PEN)
but not as an outside conductor.

Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2

Construction

Insulationresistance:
min. 100 MOhm X km

Bare, solid or multiple strands of copper wire,


halogen-free cross-linked PE core insulation, core
colours acc. to DIN VDE 0293, part 308, cores
twisted in layers. Halogen-free inner sheat,
concentric bare copper wire shield with copper
tape. Outer sheath out of flame retardant,
halogenfree polymer mixture
(acc. to IEC 60332-3). Colour black.

480

Technicaldata
Ratedvoltage:
0,6/1 kV
Testvoltage:
4000 V

fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
12 X cable diameter

Approvals:
acc. to DIN VDE 0276, part 604

ConCab kabel connects the world

Part-No.

No.ofcores
+
cross-section

Copper Outer Weight


weight diameter
approx.
kg/km
mm
kg/km

858 0015 002 2 X 1,5 RE/1,5


858 0015 003 3 X 1,5 RE/1,5
858 0015 004 4 X 1,5 RE/1,5
858 0015 007 7 X 1,5 RE/2,5*
858 0015 012 12 X 1,5 RE/2,5*
858 0015 024 24 X 1,5 RE/6*
858 0015 030 30 X 1,5 RE/6*

52,0
66,0
81,0
133,0
205,0
413,0
499,0

14,0
14,5
15,5
18,0
20,5
24,0
28,0

170
250
300
350
550
780
1000

858 0025 002 2 X 2,5 RE/2,5


858 0025 003 3 X 2,5 RE/2,5
858 0025 004 4 X 2,5 RE/2,5
858 0025 007 7 X 2,5 RE/2,5*
858 0025 012 12 X 2,5 RE/4*
858 0025 030 30 X 2,5 RE/10*

80,0
104,0
128,0
200,0
334,0
840,0

15,0
15,5
16,5
19,0
22,5
31,0

280
320
380
440
750
1500

858 0040 003


858 0040 004
858 0040 007

3 X 4 RE/4
4 X 4 RE/4
7 X 4 RE/4*

161,0
200,0
315,0

16,5
17,5
20,0

400
480
610

858 0060 003


858 0060 004
858 0060 007

3 X 6 RE/6
4 X 6 RE/6
7 X 6 RE/6*

240,0
297,0
470,0

18,0
19,0
21,5

500
600
850

858 0100 003


858 0100 004

3 X 10 RE/10
4 X 10 RE/10

408,0
504,0

20,0
21,5

750
850

858 0160 003


858 0160 004

3 X 16 RE/16
4 X 16 RE/16

643,0
796,0

22,5
24,5

1000
1200

858 0250 003


858 0250 004

3 X 25 RM/16
4 X 25 RM/16

1003,0
1142,0

27,0
29,0

1600
1800

858 0350 003


858 0350 004

3 X 35 RM/16
4 X 35 RM/16

1402,0
1526,0

27,5
29,5

1900
2100

858 0500 004

4 X 50 SM/25

2203,0

32,5

2800

858 0700 004

4 X 70 SM/35

3082,0

38,0

3800

858 0950 004

4 X 95 SM/50

4208,0

43,5

5100

858 1200 004

4 X 120 SM/70

5388,0

47,5

6300

858 1500 004

4 X 150 SM/70

6540,0

53,0

7500

858 1850 004

4 X 185 SM/95

8159,0

55,0

8900

858 2400 004

4 X 240 SM/120 10546,0

61,0

11200

ConductormarkingsRE,RM,SMrefertotechnicalappendix
*acc.toDINVDE0250,part214

481

CC-powercableNHXH-J/OE30/FE180-860

Halogen-freewithelectricalfunctionE30acc.toDIN4102,0,6/1KV
InsulationintegrityFE180acc.toIEC60331
ConformstotheEUlow-voltageguideline73/23/EEC

ConCab kabel Mainhardt 860 3G1,5 NHXH-J E30/FE 180

The halogen-free CC-power cable


NHXH-J/O E30/FE180-860 is used
primarily in power stations and substations as well as
in buildings where a demand for increased protection
for humans and goods is. The functional and
insulation performance requirements of the cable have
to comply with a higher level of safety.
It is ideal to be laid over, on, inside and under plaster
in dry, damp and wet rooms as well as in brickwork
and in concrete with the exception of cabling in
shaken, vibrated and compressed concrete. This cable
can also be used outdoors provided it is
protected from direct sunlight but not in water or
buried in ground.

Construction
Bare, solid or multiple strands of copper wire,
halogen-free cross-linked polymer core insulation,
core colours acc. to DIN VDE 0293, part 308.
NHXH-J 3 cores or more with green/yellow
protective conductor in the outer layer, cores twisted
in layers. Outer sheath flame retardant, halogen-free
polymer mixture (acc. to IEC 60332-3).
Colour orange

482

Technicaldata
Ratedvoltage:
0,6/1 kV
Testvoltage:
4000 V
Conductorstranding:
solid or multiple copper strands
acc. to DIN VDE 0295, class 1 or 2
Insulationresistance:
min. 100 MOhm X km
fixed installation:

Temperaturerange:
-40C to +70C

fixed installation:

Bendingradius:
12 X cable diameter

Approvals:
acc. to DIN VDE 0482, part
266-2DIN VDE 0472, part 814
DIN VDE 4102, part 12

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg / km
mm

Weight

Part-No.

kg/km

860 0015 002


860 0015 003
860 0015 004
860 0015 005
860 0015 007
860 0015 012
860 0015 019
860 0015 024
860 0015 030

2 X 1,5 RE
3 G 1,5 RE
4 G 1,5 RE
5 G 1,5 RE
7 G 1,5 RE
12 G 1,5 RE
19 G 1,5 RE
24 G 1,5 RE
30 G 1,5 RE

29,0
43,0
58,0
72,0
101,0
173,0
274,0
346,0
432,0

12,0
13,0
13,5
14,0
14,3
15,0
23,0
26,0
28,0

180
200
240
280
330
410
900
1100
1300

860 0025 002


860 0025 003
860 0025 004
860 0025 005
860 0025 007
860 0025 012
860 0025 019
860 0025 024
860 0025 030

2 X 2,5 RE
3 G 2,5 RE
4 G 2,5 RE
5 G 2,5 RE
7 G 2,5 RE
12 G 2,5 RE
19 G 2,5 RE
24 G 2,5 RE
30 G 2,5 RE

48,0
72,0
96,0
120,0
168,0
288,0
456,0
576,0
720,0

13,0
14,0
14,0
16,0
17,0
21,0
25,0
29,0
31,0

210
250
300
350
540
600
860
1400
1600

860 0040 001


860 0040 002
860 0040 003
860 0040 004
860 0040 005

1 X 4 RE
2 X 4 RE
3 G 4 RE
4 G 4 RE
5 G 4 RE

38,0
77,0
115,0
154,0
192,0

7,5
14,0
15,0
15,0
17,0

110
260
320
400
450

860 0060 001


860 0060 002
860 0060 003
860 0060 004
860 0060 005

1 X 6 RE
2 X 6 RE
3 G 6 RE
4 G 6 RE
5 G 6 RE

58,0
115,0
173,0
230,0
288,0

9,0
15,0
16,0
17,0
18,0

150
320
400
500
560

860 0100 001


860 0100 002
860 0100 003
860 0100 004
860 0100 005

1 X 10 RE
2 X 10 RE
3 G 10 RE
4 G 10 RE
5 G 10 RE

96,0
192,0
288,0
384,0
480,0

10,0
16,0
18,0
19,0
20,0

180
440
550
680
840

860 0160 001


860 0160 002
860 0160 003
860 0160 004
860 0160 005

1 X 16 RE
2 X 16 RE
3 G 16 RE
4 G 16 RM
5 G 16 RM

154,0
307,0
461,0
614,0
768,0

11,0
17,5
20,0
22,0
24,0

250
570
800
1000
1200

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg /km
mm

Weight
kg/ km

860 0250 001


860 0250 002
860 0250 003
860 0250 0031
860 0250 004
860 0250 005

1 X 25 RM
2 X 25 RM
3 G 25 RM
3 X 25 RM/16
4 G 25 RM
5 G 25 RM

240,0
480,0
720,0
874,0
960,0
1200,0

13,0
22,0
23,0
26,0
26,0
29,0

380
900
1200
1350
1500
1800

860 0350 001


860 0350 003
860 0350 0031
860 0350 004
860 0350 005

1 X 35 RM
3 G 35 RM
3 X 35 RM/16
4 G 35 RM
5 G 35 RM

336,0
1080,0
1162,0
1344,0
1680,0

14,0
26,0
30,0
28,5
36,0

480
1500
1700
1900
2700

860 0500 001


860 0500 003
860 0500 0031
860 0500 004
860 0500 005

1 X 50 RM
3 G 50 RM
3 X 50 RM/25
4 G 50 RM
5 G 50 RM

480,0
1440,0
1680,0
1920,0
2400,0

16,0
29,0
34,0
32,0
40,0

650
2000
2250
2500
3653

860 0700 001


860 0700 003
860 0700 0031
860 0700 004

1 X 70 RM
3 G 70 RM
3 X 70 RM/35
4 G 70 RM

672,0
2016,0
2352,0
2688,0

14,0
35,0
38,0
37,0

850
2800
3200
3400

860 0950 001


860 0950 003
860 0950 004

1 X 95 RM
3 X 95 RM/50
4 G 95 RM

912,0
3216,0
3648,0

20,0
42,0
42,0

1200
4200
4700

860 1200 001 1 X 120 RM


1152,0
860 1200 0031 3 X 120 RM/70 4128,0
860 1200 004 4 G 120 RM
4608,0

22,0
48,0
48,0

1400
5300
6007

860 1500 001 1 X 150 RM


1440,0
860 1500 0031 3 X 150 RM/70 4992,0
860 1500 004 4 G 150 RM
5760,0

24,0
53,0
53,0

1700
6300
7362

860 1850 001 1 X 185 RM


1776,0
860 1850 0031 3 G 185 RM/95 6240,0

26,5
58,0

2200
7900

860 2400 001

28,0

2500

1 X 240 RM

2304,0

For description of conductor RE, RM, SM see appendix.

ConCab kabel connects the world

483

CC-power cable NHXCH E30/FE180-861


Halogen-free with electrical function E30 acc. to DIN 4102, 0,6/1 kV
Insulation integrity FE180 acc. to IEC 60331, shielded
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 861 3x1,5/1,5 NHXCH E30/FE180

The halogen-free CC-power cable


NHXCH E30/FE180-861 is used primarily in power
stations and substations as well as in buildings where
a demand for increased protection for humans and
goods is. The functional and insulation performance
requirements of the cable have to comply with a
higher level of safety. It is ideal to be laid over, on,
inside and under plaster in dry, damp and wet rooms
as well as in brickwork or concrete with the exception
of cabling in shaken, vibrated and compressed concrete. This cable can also be applied outdoors
provided it is protected from direct sunlight. It may
not be laid in water or buried in ground. The
concentric copper conductor serves as a shield and
can be used as a neutral conductor (N) or protective
conductor (PE/PEN) but not as an outside conductor.

solid or multiple copper strands


acc. to DIN VDE 0295, class 1 or 2

Construction

Insulation resistance:

Bare, solid or multiple strands of copper wire,


halogen-free cross-linked polymer core insulation,
core colours acc. to DIN VDE 0293, part 308, 3
cores or more with green/yellow protective conductor in the outer layer, cores twisted in layers,
halogen-free filling inner sheath, concentric bare
copper wire shield with copper tape. Outer sheath
flame retardant, halogen-free polymer mixture
(acc. to IEC 60332-3).
Colour orange.

484

Technical data
Rated voltage:
0,6/1 kV

Test voltage:
4000 V

Conductor stranding:

min. 100 MOhm X km

fixed installation:
fixed installation:

Temperature range:
-40C to +70C

Bending radius:

6 X cable diameter

Approvals:

DIN 4102
VDE 0472, part 814 and IEC 60331

ConCab kabel connects the world

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg / km

861 0015 002 2 X 1,5 RE/1,5


861 0015 003 3 X 1,5 RE/1,5
861 0015 004 4 X 1,5 RE/1,5
861 0015 007 7 X 1,5 RE/2,5
861 0015 030 30 X 1,5 RE/6

52,0
66,0
81,0
133,0
499,0

15,0
15,0
17,0
18,0
31,0

250
250
300
480
1400

861 0700 003 3 X 70 RM/35


861 0700 004 4 X 70 RM/35

2410,0
3082,0

37,0
42,0

3200
4200

861 0950 003 3 X 95 RM/50


861 0950 004 4 X 95 RM/50

3296,0
4208,0

41,0
47,0

4200
5700

861 0025 002


861 0025 003
861 0025 004

2 X 2,5 RE/2,5
3 X 2,5 RE/2,5
4 X 2,5 RE/2,5

80,0
104,0
128,0

16,0
16,0
18,0

280
320
400

861 1200 003 3 X 120 RM/70


861 1200 004 4 X 120 RM/70

4236,0
5388,0

47,0
53,0

5350
7200

861 0040 002


861 0040 003
861 0040 004

2 X 4 RE/4
3 X 4 RE/4
4 X 4 RE/4

123,0
161,0
200,0

17,0
17,0
19,0

350
400
470

861 1500 003 3 X 150 RM/70


861 1500 004 4 X 150 RM/70

5100,0
6540,0

52,0
58,0

6400
8700

861 1850 003 3 X 185 RM/95


861 1850 004 4 X 185 RM/95

6383,0
8159,0

56,0
65,0

7900
10500

861 0060 002


861 0060 003
861 0060 004

2 X 6 RE/6
3 X 6 RE/6
4 X 6 RE/6

182,0
240,0
297,0

18,0
18,0
21,0

450
500
600

861 2400 003 3 X 240 RM/120 8242,0


861 2400 004 4 X 240 RM/120 10546,0

64,0
65,0

9800
10500

861 0100 002


861 0100 003
861 0100 004

2 X 10 RE/10
3 X 10 RE/10
4 X 10 RE/10

312,0
408,0
504,0

20,0
20,0
23,0

650
750
850

861 0160 003


861 0160 004

3 X 16 RE/16
4 X 16 RE/16

643,0
796,0

23,0
26,0

1100
1250

861 0250 003


861 0250 004

3 X 25 RM/16
4 X 25 RM/16

1003,0
1142,0

27,0
30,0

1500
1800

861 0350 003


861 0350 004

3 X 35 RM/16
4 X 35 RM/16

1402,0
1526,0

30,0
33,0

1900
2300

861 0500 003


861 0500 004

3 X 50 RM/25
4 X 50 RM/25

1723,0
2203,0

32,5
37,0

2300
3000

For description of conductor RE, RM, SM see appendix.

ConCab kabel connects the world

485

CC-power cable NHXH-J/O E90/FE180-862


Halogen-free with electrical function E90 acc. to DIN 4102, 0,6/1 kV
Insulation integrity FE180 acc. to IEC 60331
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 862 3G2,5 NHXH-J E90/FE180

The halogen-free CC-power cable


NHXH-J/O E90/FE180-862 is used primarily in power
stations and substations as well as in buildings where
a demand for increased protection for humans and
goods is. The functional and insulation requirements of
the cable have to comply with a higher level of safety.
It is ideal to be laid over, on, inside and under plaster in
dry, damp and wet rooms as well as in brickwork or
concrete with the exception of cabling in shaken,
vibrated and compressed concrete. This cable can also be
applied outdoors provided it is protected from direct
sunlight. It may not be laid in water or buried in ground.
The concentric copper conductor serves as a shield and
can be used as a neutral conductor (N) or protective
conductor (PE/PEN) but not as an outside conductor.

Technical data
Rated voltage:
0,6/1 kV

Test voltage:
4000 V

Conductor stranding:

single or multiple copper strands


acc. to DIN VDE 0295, class 1 or 2

Insulation resistance:

min. 100 MOhm X km

Construction
Bare, solid or multiple strands of copper wire,
halogen-free cross-linked polymer core insulation with
additional fire protection, core colours acc. to DIN
VDE 0293, part 308 with NHXH-J, 3 cores or more
with green/yellow protective conductor in the outer
layer, cores twisted in layers, halogen-free filling inner
sheath with flame protection wrapping. Outer sheath
flame retardant halogen-free polymer mixture acc. to
IEC (60332-3). Colour orange.

486

Temperature range:

fixed installation:

-40C to + 70C

fixed installation:

6 X cable diameter

Bending radius:

Approvals:

acc. to DIN VDE 0266, DIN 4102


VDE 0472, part 814 and IEC 60331

ConCab kabel connects the world

Part-No.

862 0015 002


862 0015 003
862 0015 004
862 0015 005
862 0015 007
862 0015 010
862 0015 012
862 0015 024

No. of cores
+
crosssection
2 X 1,5 RE
3 G 1,5 RE
4 G 1,5 RE
5 G 1,5 RE
7 G 1,5 RE
10 G 1,5 RE
12 G 1,5 RE
24 G 1,5 RE

Copper Outer
weight diameter
approx.
kg/km
mm

Weight

Part-No.

kg/km

29,0
43,0
58,0
72,0
101,0
144,0
173,0
346,0

15,0
16,0
17,0
18,0
18,0
21,0
26,0
32,0

280
300
350
400
480
500
700
1400

862 0025 002 2 X 2,5 RE


862 0025 003 3 G 2,5 RE
862 0025 004 4 G 2,5 RE
862 0025 005 5 G 2,5 RE
862 0025 007 7 G 2,5 RE
862 0025 010 10 G 2,5 RE
862 0025 012 12 G 2,5 RE

48,0
72,0
96,0
120,0
168,0
240,0
288,0

16,0
17,0
18,0
19,0
20,0
23,0
28,0

320
380
420
480
600
780
900

862 0040 002


862 0040 003
862 0040 004
862 0040 005
862 0040 007

2 X 4 RE
3 G 4 RE
4 G 4 RE
5 G 4 RE
7 G 4 RE

77,0
115,0
154,0
192,0
269,0

17,0
18,0
19,0
21,0
22,0

380
450
550
600
800

862 0060 002


862 0060 003
862 0060 004
862 0060 005

2 X 6 RE
3 G 6 RE
4 G 6 RE
5 G 6 RE

115,0
173,0
230,0
288,0

18,0
19,0
20,0
22,0

450
550
650
750

862 0100 002


862 0100 003
862 0100 004
862 0100 005

2 X 10 RE
3 G 10 RE
4 G 10 RE
5 G 10 RE

192,0
288,0
384,0
480,0

20,0
21,0
23,0
25,0

600
750
900
1100

862 0160 001


862 0160 002
862 0160 003
862 0160 004
862 0160 005

1 X 16 RM
2 X 16 RM
3 G 16 RM
4 G 16 RM
5 G 16 RE

154,0
307,0
461,0
614,0
768,0

12,0
22,0
23,0
26,0
28,0

290
800
1000
1200
1400

862 0250 001


862 0250 002
862 0250 003
862 0250 004
862 0250 005

1 X 25 RM
2 X 25 RM
3 G 25 RM
4 G 25 RM
5 G 25 RE

240,0
480,0
720,0
960,0
1200,0

13,0
26,0
25,0
28,0
30,0

390
1200
1450
1600
1800

862 0350 001


862 0350 002
862 0350 003
862 0350 0031
862 0350 004
862 0350 005

1 X 35 RM
2 X 35 RM
3 G 35 RM
3 X 35 RM/16
4 G 35 RM
5 G 35 RE

336,0
672,0
1008,0
1162,0
1344,0
1680,0

15,0
27,0
28,0
31,0
31,0
33,0

520
1450
1500
1900
2000
2350

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg / km

862 0500 001


862 0500 002
862 0500 003
862 0500 0031
862 0500 004
862 0500 005

1 X 50 RM
2 X 50 RM
3 G 50 RM
3 X 50 RM/25
4 G 50 RM
5 G 50 RM

480,0
960,0
1440,0
1680,0
1920,0
2500,0

16,0
30,0
33,0
36,0
34,0
38,0

670
1950
2450
2700
2900
3100

862 0700 001


862 0700 002
862 0700 003
862 0700 0031
862 0700 004
862 0700 005

1 X 70 RM
2 X 70 RM
3 G 70 RM
3 X 70 RM/35
4 G 70 RM
5 G 70 RM

672,0
1344,0
2016,0
2352,0
2688,0
3360,0

18,0
34,0
37,0
40,0
39,0
45,0

910
2650
3300
3500
3600
5100

862 0950 001


862 0950 002
862 0950 003
862 0950 0031
862 0950 004

1 X 95 RM
2 X 95 RM
3 G 95 RM
3 X 95 RM/50
4 G 95 RM

912,0
1824,0
2736,0
3216,0
3648,0

21,0
39,0
42,0
46,0
44,0

1200
3450
4400
4700
4800

862 1200 001


862 1200 002
862 1200 003
862 1200 0031
862 1200 004

1 X 120 RM
2 X 120 RM
3 G 120 RM
3 X 120 RM/70
4 G 120 RM

1152,0
2304,0
3456,0
4128,0
4608,0

22,0
41,0
44,0
49,0
48,0

1500
4050
5150
5800
6000

862 1500 001


862 1500 003
862 1500 0031
862 1500 004

1 X 150 RM
3 G 150 RM
3 X 150 RM/70
4 G 150 RM

1440,0
4320,0
4992,0
5760,0

24,0
49,0
52,0
54,0

1800
6350
7200
8100

862 1850 001


862 1850 003
862 1850 0031
862 1850 004

1 X 185 RM
3 G 185 RM
3 X 185 RM/95
4 G 185 RM

1776,0
5328,0
6240,0
7104,0

27,0
54,0
56,0
60,0

2200
7800
8800
9900

862 2400 003 3 G 240 RM


6912,0
862 2400 0031 3 X 240 RM/120 8064,0
862 2400 004 4 G 240 RM
9216,0

61,0
63,0
67,0

10100
11100
12900

862 3000 001

1 X 300 RM

2880,0

33,0

3400

862 4000 001

1 X 400 RM

3840,0

36,0

4300

For description of conductor RE, RM, SM see appendix.

487

CC-power cable NHXCH E90/FE180-863


Halogen-free with electrical function E90 acc. to DIN 4102 0,6/1 kV
Insulation integrity FE180 acc. to IEC 60331, shielded
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 863 3x1,5/1,5 NHXCH E90/FE180

The halogen-free CC-power cable


NHXCH E90/FE180-863 is used primarily in power
stations and substations as well as in buildings where
there is a demand for increased protection for humans
and goods as the functional and insulation performance requirements of the cable have to comply with a
higher level of safety. It is ideal to be laid over, on,
inside and under plaster in dry, damp and wet rooms
as well as in brickwork or concrete with the exception
of cabling in shaken, vibrated and compressed concrete. This cable can also be applied outdoors
provided it is protected from direct sunlight. It may
not be laid in water or buried in ground. The
concentric copper conductor serves as a shield and
can be used as a neutral conductor (N) or protective
conductor (PE/PEN) but not as an outside conductor.

solid or multiple copper strands


acc. to DIN VDE 0295, class 1 or 2

Construction

Insulation resistance:

Bare, solid or multiple strands of copper wire,


halogen-free core cross-linked
polymer mixture core insulation with
additional fire protection, core colours
acc. to DIN VDE 0293, part 308, cores twisted in
layers, halogen-free filling inner sheath, concentric
shield out of bare copper wires with copper tape.
Outer sheath out of flame retardant, halogen-free
polymer mixture (acc. to IEC 60332-3).
Colour orange.

488

Technical data
Rated voltage:
0,6/1kV

Test voltage:
4000 V

Conductor stranding:

min. 100 MOhm X km

fixed installation:
fixed installation:

ConCab kabel connects the world

Temperature range:

-40C to +70C

Bending radius:

12 X cable diameter

Approvals:

acc. to DIN VDE 0266

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg/km
mm

Weight
kg/km

863 0015 003 3 X 1,5 RE/1,5


863 0015 004 4 X 1,5 RE/1,5
863 0015 007 7 X 1,5 RE/2,5
863 0015 012 12 X 1,5 RE/2,5
863 0015 024 24 X 1,5 RE/6
863 0015 030 30 X 1,5 RE/6

66,0
81,0
133,0
205,0
413,0
499,0

17,0
18,0
22,0
27,0
34,0
36,0

320
450
600
750
1300
1500

863 0025 003 3 X 2,5 RE/1,5


863 0025 004 4 X 2,5 RE/2,5
863 0025 007 7 X 2,5 RE/2,5
863 0025 012 12 X 2,5 RE/4
863 0025 024 24 X 2,5 RE/10
863 0025 030 30 X 2,5 RE/10

104,0
128,0
200,0
334,0
696,0
840,0

18,0
19,0
22,0
28,0
37,0
39,0

380
500
650
950
1700
1900

863 0040 003


863 0040 004
863 0040 005

3 X 4 RE/4
4 X 4 RE/4
5 X 4 RE/4

161,0
200,0
238,0

19,0
21,0
21,0

480
600
600

863 0060 003


863 0060 004

3 X 6 RE/6
4 X 6 RE/6

240,0
297,0

20,0
22,0

600
750

863 0100 003


863 0100 004

3 X 10 RE/10
4 X 10 RE/10

408,0
504,0

23,0
25,0

850
1100

863 0160 003


863 0160 004

3 X 16 RM/16
4 X 16 RM/10

643,0
796,0

26,0
29,0

1200
1500

863 0250 003


863 0250 004

3 X 25 RM/16 1003,0
4 X 25 RM/16 1142,0

30,0
32,0

1700
2000

863 0350 003


863 0350 004

3 X 35 RM/16 1402,0
4 X 35 RM/16 1526,0

32,0
35,0

2200
2500

863 0500 003


863 0500 004

3 X 50 RM/25 1723,0
4 X 50 RM/25 2203,0

36,0
40,0

2400
3300

863 0700 003


863 0700 004

3 X 70 RM/35 2410,0
4 X 70 RM/35 3082,0

41,0
44,0

2800
4400

Part-No.

No. of cores
+
crosssection

Copper Outer
weight diameter
approx.
kg /km
mm

Weight
kg/ km

863 0950 003 3 X 95 RM/50


863 0950 004 4 X 95 RM/50

3296,0
4208,0

47,0
52,0

4500
6100

863 1200 003 3 X 120 RM/70


863 1200 004 4 X 120 RM/70

4236,0
5388,0

51,0
57,0

5600
7500

863 1500 003 3 X 150 RM/70


863 1500 004 4 X 150 RM/70

5100,0
6540,0

54,0
62,0

6400
9000

863 1850 003 3 X 185 RM/95


863 1850 004 4 X 185 RM/95

6383,0
8159,0

62,0
68,0

8800
11000

863 2400 003 3 X 240 RM/120 8242,0


863 2400 004 4 X 240 RM/120 10546,0

70,0
76,0

11300
14500

For description of conductor RE, RM, SM see appendix.

ConCab kabel connects the world

489

491

CC-single core PVC


LiYv-365 | H05V-K/X05V-K-370
H07V-K/X07V-K-380 | H05/ H07V-U- 360
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 380 H07V-K

LiYv:

Hook-up wire used for wiring electronic


components, transmitting apparatus and
telecommunication systems.

H05V-K resp. X05V-K, H05V-U:

PVC hook-up wire for internal wiring of


electrical appliances. The cable is ideal for
protected wiring in switchgear cabinets. It
can be laid in conduits on- and under plaster,
but only for signal and control systems.

H07V-K resp. X07V-K, H07V-U:

PVC hook-up wire for internal wiring of


electrical appliances is ideal for
protected wiring in switchgear cabinets.
It can be laid in and underneath plaster only
in closed installation channels and tubes.
The cable is not suitable for direct laying on
trays and racks.

Technical data
LiYv:

Tinned, fine copper strands


acc. to DIN VDE 0295, class 5. PVC core
insulation YI3 flame retardant (acc. to
DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
LiYv
Rated voltage (V):
Test voltage (V):

300 V (0,14mm2)
500 V (L = 0,14mm2)
1200 V (0,14mm2)
2500 V ( 0,14mm2)

Insulation resistance:
Temperature range
Fixed installation:
Flexible application:
Approvals:
acc. to DIN VDE
0281, part 3

492

H05V-K/X05V-K:

Bare, fine copper strands acc. to


DIN VDE 0295, class 5. PVC core insulation
TI1 flame retardant (acc. to DIN VDE 0482,
part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
H05V-K:
single colour and green/yellow
X05V-K:
single and multicoloured

H07V-K/X07V-K:

Bare, fine copper strands


acc. to DIN VDE 0295, class 5. PVC core
insulation TI1 flame retardant (acc. to
DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
H07V-K:
single colour and green/yellow
X07V-K:
single and multicoloured

H05V-U/ H07V-U:

Bare, solid copper wire


acc. to DIN VDE 0295, class 1. PVC core
insulation TI1 flame retardant (acc. to
DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
H05/H07V-U: single colour and green/yellow
X05/X07V-U:
single and multicoloured
H05V-K/X05V-K
H05V-U

H07V-K/X07V-K
H07V-U

300/500 V

450/750 V

2000 V

2500 V

min. 20 MOhm X km
-30C to +70C
-5C to +70C
acc. to DINVDE 0281, part 3 and
acc. to HD 21.3.S3

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

0,14
0,25
0,50
0,75

0,50
0,75
1,0

Outer
diameter
approx.
mm

Weight

2,8 - 3,4
3,4 - 4,1
3,9 - 4,8
4,4 - 5,3
5,7 - 6,8
6,7 - 8,1
8,4 - 10,2
9,7 - 11,7
11,5 - 13,9
13,2 - 16,0
15,1 - 18,2
16,7 - 20,2
18,6 - 22,5
20,6 - 24,9
23,5 - 28,4

20
32
46
65
113
170
260
360
515
710
940
1180
1480
1805
2350

kg / km

H07V-K/X07V-K

1,4
2,4
4,8
7,2

1,0 1,2 1,7 1,9 -

1,2
1,4
2,0
2,2

3
5
8
12

2,1 - 2,6
2,2 - 2,8
2,4 - 2,9

8
12
14

H05V-K/X05V-K
370 05 ..
370 07 ..
370 10 ..

Copper
weight
kg/km

kg/km

LiYv
365 01 ..
365 02 ..
365 05 ..
365 07 ..

Crosssection

4,8
7,2
9,6

380 0015 ..
380 0025 ..
380 0040 ..
380 0060 ..
380 0100 ..
380 0160 ..
380 0250 ..
380 0350 ..
380 0500 ..
380 0700 ..
380 0950 ..
380 1200 ..
380 1500 ..
380 1850 ..
380 2400 ..

1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

14,4
24,0
38,4
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

H05V-U/X05V-U - H07V-U/X07V-U
360 05 ..
360 07 ..
360 10 ..
360 0015 ..
360 0025 ..
360 0040 ..
360 0060 ..
360 0100 ..

0,5
0,75
1,0
1,5
2,5
4,0
6,0
10,0

4,8
7,2
9,6
14,4
24,0
38,4
58,0
96,0

2,1 - 2,6
2,2 - 2,8
2,4 - 2,9
2,8 - 3,4
3,4 - 4,1
3,9 - 4,8
4,4 - 5,3
5,7 - 6,8

8
12
14
20
32
46
65
113

Please complete the Part-No. .. when ordering with the following ref. number = Colour
00 black
01 blue
02 brown
03 red
04 white
05 grey
06 violet
07 pink
08 orange
09 yellow
10 green
Note:

11 beige
12 dark blue
13 blackgreen
14 blackred
15 blackwhite
16 blueblack
17 bluegreen
18 bluered
19 bluewhite
20 brownblack
21 browngreen

22 brownwhite
23 yellowblack
24 yellowred
25 yellowwhite
26 greenblack
27 greenwhite
28 violetblack
29 violetyellow
30 violetwhite
31 orangeblack
32 orangewhite

33 redblack
34 redyellow
35 redwhite
36 whiteblack
37 whiteblue
38 whitebrown
39 whitered
40 greyblack
50 transparent
99 green/yellow

Multicoloured cores with the exception of green/yellow are not harmonized types.
Solid and multiwire single cores of type H05V-U and H07V-U/R on request.

493

CC-single core PVC


H05V2-K-384
H07V2-K-384
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 384 H07V2-K

Technical data

H05V2-K:
PVC hook-up wire for internal wiring of
electrical appliances for temperatures of up
to 90C on the conductor. The wire is ideal
for protective wiring in appliances where
higher temperatures can occur. It is not
suitable for direct contact with appliances
producing temperatures higher than 85C.

H05V2-K (300/500 V):


bare, fine copper strands acc. to DIN VDE
0295, class 5. PVC core insulation TI3 flame
retardant (acc. to DIN VDE 0482, part 265-21 resp. EN 50265-2-1 and IEC 60332-1).
Single colour and green/yellow.

H07V2-K:
PVC hook-up wire for inside wiring of
electrical appliances as well as for the
protective wiring to and in appliances that
permit temperatures of up to 90C.
The wire is not suitable for direct laying
on trays and racks.
Part-No.

Crosssection

Copper
weight
kg/km

H07V2-K (450/750 V):


bare, fine copper strands acc. to DIN VDE
0295, class 5. PVC core insulation TI3 flame
retardant (acc. to DIN VDE 0482, part 265-21 resp. EN 50265-2-1 and IEC 60332-1).
Single colour and green/yellow.

Outer
diameter
approx.
mm

Weight

2,1 - 2,5
2,2 - 2,7
2,4 - 2,8

8
12
18

2,8 - 3,4
3,4 - 4,1
3,9 - 4,8
4,4 - 5,3
5,7 - 6,8
6,7 - 8,1
8,4 - 10,2
9,7 - 11,7

22
37
50
71
130
187
294
380

Temperature range:
fixed installation: -10C to + 90C

kg/km

H05V2-K
384 0005 ..
384 0007 ..
384 0010 ..

0,50
0,75
1,0

5,5
8,0
10,8
H07V2-K

384 0015 ..
384 0025 ..
384 0040 ..
384 0060 ..
384 0100 ..
384 0160 ..
384 0250 ..
384 0350 ..

1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0

15,0
25,0
40,0
60,0
100,0
160,0
240,0
336,0

Please complete the Part-No... when ordering with the following ref. number = Colour
00 black
01 blue
02 brown
03 red

494

04 white
05 grey
06 violet
07 pink

08 orange
09 yellow
10 green

11 beige
12 darkblue
99 green/yellow

C-single core LiFY-363


High flexible, fine stranded single core 1 kV
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 363 LiFY 1 kV

The high flexible CC-single core LiFY-363


is mainly used for connecting
appliances often moved from place to place,
e.g., measuring appliance wire in a
laboratory or for rapid temporary
installation of testing appliances.

Construction
Bare, fine strands of copper wire,
PVC core insulation,
flame retardant and self-extinguishing
(acc. to DIN VDE 0482, part 265-2-1 resp.
EN 50265-2-1 and IEC 60332-1).
Single colour and green/yellow.
Part-No.

Crosssection

Copper
weight
kg/km

363 00010 0..


363 00014 0..
363 00025 0..
363 00050 0..
363 00075 0..
363 00100 0..
363 00150 0..
363 00250 0..
363 00400 0..
363 00600 0..
363 01000 0..
363 01600 0..
363 02500 0..
363 03500 0..
363 05000 0..
363 07000 0..

0,10
0,14
0,25
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0

Outer
diameter
approx.
mm

1,2
1,4
2,5
5,5
8,0
10,8
15,0
25,0
40,0
60,0
100,0
160,0
240,0
336,0
480,0
672,0

1,0
1,1
1,4
2,0
2,2
2,5
3,5
3,8
5,0
6,5
7,5
9,0
10,5
11,7
14,7
17,0

Weight
kg/km
2
3
4
8
12
18
22
37
50
71
130
187
294
380
521
740

Technical data
Rated voltage:
1000 V

Test voltage:
3000 V

Conductor stranding:

bare, fine copper strands


acc. to DIN VDE 0295,
class 6 (0,07 mm wire)

Insulation resistance:

min. 20 MOhm X km

Temperature range:
-15C to +80C

Bending radius:

7 X cable diameter

Approvals:

acc. to DIN VDE 0281

Please complete the Part-No... when ordering with the following ref. number = colour
00 black
01 blue
02 brown
03 red

04 white
05 grey
06 violet
07 pink

08 orange
09 yellow
10 green

11 beige
12 darkblue
99 green/yellow

ConCab kabel connects the world

495

CC-single core PVCUL/CSA


UL style 1007/1569, CSA TR 64
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt cus AWM STYLE 1007/1569 AWG14 VW1-CSA TR 64 FT1 300V 105C

ConCab kabel Mainhardt cus AWM STYLE 1007/1569 AWG14 VW1-CSA TR 64 FT1 300V 105C

Technical data
Rated voltage:
300 V

Test voltage:
3000 V

Spark test (Test voltage):


AWG 28 - 20: 4 kV
AWG 18 - 10: 5 kV

The CC-single cores acc. to UL/CSA are suitable for


internal wiring of electrical appliances, switchgear
cabinets and telecommunication
systems. They can also be used to connect machines
and motors provided they are laid in protective pipes
or flexible conduits.

Core insulation:

PVC mixture acc. to UL: VW-1


CSA: FT 1

Insulation resistance:

min. 20 MOhm X km

Construction
Bare or tinned fine strands of copper wire, PVC core
insulation (acc. to UL style 1007/1569
and CSA TR64).
For colours refer to adjacent table.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)

496

Approvals:

AWG 32 - 16: UL style 1007 (300 V/80C)


AWG 28 - 10: UL style 1569 (300 V/105C)
CSA TR 64 (300V/90C)
Temperature range:
UL-Style 1007 : -40C to + 80C
UL-Style 1569 : -40C to + 105C
CSA TR 64: -40C to + 90C

ConCab kabel connects the world

Part-No.

AWG

1007 28 . ..
1007 26 . ..
1007 24 . ..
1007 22 . ..
1007 20 . ..
1007 18 . ..
1007 16 . ..
1007 14 . ..
1007 12 . ..
1007 10 . ..

Specification:

28
26
24
22
20
18
16
14
12
10

Crosssection

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

mm2
0,08
0,13
0,22
0,34
0,56
0,80
1,30
2,10
3,30
5,26

0,8
1,3
2,1
3,3
5,4
7,7
12,0
20,0
33,0
51,6

1,2
1,3
1,4
1,6
1,9
2,2
2,5
2,9
3,9
4,1

2,8
3,2
4,3
6,0
8,5
12,5
18,5
29,0
40,0
61,0

kg/km

Please complete the Part No. 1007


when ordering with the following ref. number:

1007 Cross-section
Specification
Colour
0 = Cu bare
1 = Cu tinned
00 black
01 blue
02 brown
03 red
04 white
05 grey
06 violet
07 pink
08 orange
09 yellow
10 green

11 beige
12 darkblue
13 blackgreen
14 blackred
15 blackwhite
16 blueblack
17 bluegreen
18 bluered
19 bluewhite
20 brownblack
21 browngreen

22 brownwhite
23 yellowblack
24 yellowred
25 yellowwhite
26 greenblack
27 greenwhite
28 violetblack
29 violetyellow
30 violetwhite
31 orangeblack
32 orangewhite

33 redblack
34 redyellow
35 redwhite
36 whiteblack
37 whiteblue
38 whitebrown
39 whitered
40 greyblack
50 transparent
99 green/yellow

Example:
1007 28 1 00 = AWG 28, CU tinned, colour black

ConCab kabel connects the world

497

CC-Multinorm MTW/AWM-CSA-HAR
Single core H05V2-K, UL-Style 1007/1569 and CSA TR 64
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt H05V-K 1QMM <HAR> cus AWM STYLE 1007/1569 AWG18 VW1-CSA TR 64 FT1 300 V 105 C

ConCab kabel Mainhardt H05V-K 1QMM <HAR> cus AWM STYLE 1007/1569 AWG18 VW1-CSA TR 64 FT1 300 V 105 C

Technical data
DIN VDE/IEC:
UL/CSA:

Rated voltage:
300/500 V
300 V
Test voltage:
2500 V

Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
The CC-single cores acc. to UL/CSA and HAR, are
suitable for internal wiring of electrical appliances,
switchgear cabinets and telecommunication
systems. They can also be used to connect machines
and motors provided they are laid in protective pipes
or flexible conduits.

Construction
Bare or tinned fine strands of copper wire, PVC core
insulation (acc. to UL style 1007/1569
and CSA TR64).
For colours refer to adjacent table.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Kanada)

498

Core insulation:
PVC-mixture acc. to UL:
VW-1
CSA:
FT1
Insulation resistance:
min. 20 MOhm X km
HAR/IEC:
UL-Style 1007:
UL-Style 1569:
CSA TR 64:

Temperature range:
-40C up to +90C
-40C up to +80C
-40C up to +105C
-40C up to +90C

Norms:
acc. to DIN VDE 0281/ HD 21
UL-Style AWM:
1007/ 1569
CSA:
TR 64 FT1

ConCab kabel connects the world

Part-No.

Crosssection

AWG

mm2
1007 0005 . ..
1007 0007 . ..
1007 0010 . ..

Specification:

0,50
0,75
1,00

22
20
18

Copperweight

Outerdiameter
approx.

Weight

kg/km

mm

kg/km

4,8
7,2
9,6

2,2
2,4
2,5

8,6
11,2
18,6

Please complete the Part No. 1007


when ordering with the following ref. number

1007 Cross-section
Conductor
Colour

Conductor:
0 = Cu bare
1 = Cu tinned
00 black
01 blue
02 brown
03 red
04 white
05 grey
06 violet
07 pink
08 orange
09 yellow
10 green

11 beige
12 darkblue
13 blackgreen
14 blackred
15 blackwhite
16 blueblack
17 bluegreen
18 bluered
19 bluewhite
20 brownblack
21 browngreen

22 brownwhite
23 yellowblack
24 yellowred
25 yellowwhite
26 greenblack
27 greenwhite
28 violetblack
29 violetyellow
30 violetwhite
31 orangeblack
32 orangewhite

33 redblack
34 redyellow
35 redwhite
36 whiteblack
37 whiteblue
38 whitebrown
39 whitered
40 greyblack
50 transparent
99 green/yellow

Example:
1007 28 1 00 = 0,50mm2/AWG 28, CU tinned, colour black

ConCab kabel connects the world

499

CC-single core PVC MTW or AWM


UL style 1015/1028/1283/1284, CSA-TEW (600V/105C)
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt cus MTW/AWM STYLE 1015 AWG8 VW1-CSA TEW FT1 600 V 105 C

ConCab kabel Mainhardt cus MTW/AWM STYLE 1015 AWG8 VW1-CSA TEW FT1 600 V 105 C

Technical data
Rated voltage:
600 V

Test voltage:
3000 V

Spark test (Test voltage):


AWG 24:
AWG 22 - 20:
AWG 18 - 10:
M AWG 8:

4 kV
5 kV
6 kV
7,5 kV

Core insulation:
PVC mixture acc. to UL:
CSA:
The CC-single core MTW or AWM is suitable for
appliance wiring and machine tool wiring as well as
in control systems. They can also be used in pipes
and flexible conduits.

Construction
Bare or tinned fine strands of
copper wire, PVC core insulation acc. to UL- MTW
or AWM style 1015, 1028, 1283, 1284 and CSATEW. For colours refer to adjacent table.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
MTW = Machine Tool Wire

500

VW-1
FT 1

Insulation resistance:
min. 20 MOhm X km

Approvals:
AWG 2 8 - 9: UL MTW or AWM style 1015
AWG 8: UL MTW or AWM style 1028
AWG 6 - 2: UL MTW or AWM style 1283
AWG 1-4/0: UL MTW or AWM style 1284
CSA-TEW
UL-AWM:
UL-MTW:
CSA TEW:

ConCab kabel connects the world

Temperature range:
-40C to +105C
-40C to +90C
-40C to + 105C

Part-No.

AWG

Crosssection

Copper
weight

mm2

kg/km

Outerdiameter
approx.
mm

Weight
kg/km

UL Style MTW or AWM 1015, 1028, 1283, 1284,


CSA TEW 600V/105C tinned
1015 24 ...
1015 22 ...
1015 20 ...
1015 18 ...
1015 16 ...
1015 14 ...
1015 12 ...
1015 10 ...
1028 08 ...
1283 06 ...
1283 04 ...
1283 03 ...
1283 02 ...
1284 01 ...
1284 1 ...
1284 2 ...
1284 3 ...
1284 4 ...

24
22
20
18
16
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0

0,22
0,34
0,56
0,80
1,38
2,10
3,30
5,26
8,39
13,3
21,2
26,7
33,6
42,4
53,7
67,6
85,0
107,2

2,1
3,3
5,5
8,5
13,9
20,7
33,5
52,4
88,5
135,0
208,0
255,0
331,0
399,0
520,0
702,0
838,0
1056,0

2,2
2,4
2,7
2,9
3,1
3,5
4,0
4,6
6,7
8,5
9,7
10,2
11,1
12,6
14,6
15,7
17,6
19,2

7
9
12
16
24
33
42
65
110
175
260
340
380
500
608
770
1179
1521

19,6
20,9
22,2
25,8

1280
1518
1756
2475

600V/105C bare
1284 250 ...
1284 300 ...
1284 350 ...
1284 500 ...

MCM 250
MCM 300
MCM 350
MCM 500

Specification:

127,0
152,0
178,0
254,0

1178,0
1410,0
1645,0
2345,0

Please complete the Part No.


when ordering with the following ref. number:

0 = Cu bare
1 = Cu tinned
See list overview
Specification
Colour
00 black
01 blue
02 brown
03 red
04 white
05 grey
06 violet
07 pink
08 orange
09 yellow
10 green

11 beige
12 darkblue
13 blackgreen
14 blackred
15 blackwhite
16 blueblack
17 bluegreen
18 bluered
19 bluewhite
20 brownblack
21 browngreen

22 brownwhite
23 yellowblack
24 yellowred
25 yellowwhite
26 greenblack
27 greenwhite
28 violetblack
29 violetyellow
30 violetwhite
31 orangeblack
32 orangewhite

33 redblack
34 redyellow
35 redwhite
36 whiteblack
37 whiteblue
38 whitebrown
39 whitered
40 greyblack
50 transparent
99 green/yellow

501

CC-Multinorm MTW/ AWM-CSA-HAR


Single core H07V-K, UL Style 1015/1028/1283/1284 and CSA TEW
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt H07V-K 1,5QMM <HAR> cus AWM/ MTW STYLE 1015 AWG16 VW1-CSA TEW FT1 600 V 105 C

ConCab kabel Mainhardt H07V-K 1,5QMM <HAR> cus AWM/ MTW STYLE 1015 AWG16 VW1-CSA TEW FT1 600 V 105 C

Technical data
Rated voltage:
DIN VDE/IEC:
450/750 V
UL/CSA:
600 V
Test voltage:
3000 V
Conductor stranding:
fine copper strands
acc. to DIN VDE 0295, class 5
Spark test (Test voltage):
AWG 24:
4 kV
AWG 22 - 20:
5 kV
AWG 18 - 10:
6 kV
M AWG 8: 7,5 kV
Core insulation:
PVC-mixture acc. to UL:VW-1
CSA:FT1
The CC-single core MTW or AWM and HAR is
suitable for appliance wiring and machine tool wiring
as well as in control systems. They can also be used
in pipes and flexible conduits.

Construction
Bare or tinned fine strands of
copper wire, PVC core insulation acc. to UL- MTW
or AWM style 1015, 1028, 1283, 1284 and
CSA-TEW. For colours refer to adjacent table.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Kanada)
MTW = Machine Tool Wire
AWM = Applience Wiring Material

502

Insulation resistance:
min. 20 MOhm X km

HAR/IEC:
UL-AWM:
UL-MTW:
CSA TEW:
AWG 28 - 9:
AWG 8:
AWG 6 - 2:
AWG 1 - 4/0:
CSA:

ConCab kabel connects the world

Temperature range:
-40C up to +90C
-40C up to +105C
-40C up to +90C
-40C up to +105C

Norms:
UL-MTW/ AWM Style 1015
UL-MTW/ AWM Style 1028
UL-MTW/ AWM Style 1283
UL-MTW/ AWM Style 1284
TEW resp. AWM

Part-No.

Crosssection

AWG

mm2

Copperweight

Outerdiameter
approx.

Weight

kg/km

mm

kg/km

UL Style MTW/ AWM 1015, 1028, 1283, 1284


CSA TEW 600 V/105C tinned
1015 0005 . ..
1015 0007 . ..
1015 0010 . ..
1015 0015 . ..
1015 0025 . ..
1015 0040 . ..
1015 0060 . ..
1015 0100 . ..
1015 0160 . ..
1015 0250 . ..
1015 0350 . ..
1015 0500 . ..
1015 0700 . ..
1015 0950 . ..
1015 1200 . ..
1015 1500 . ..

0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0

22
20
18
16
14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
300 kcmil

4,8
7,2
9,6
14,4
24,0
38,4
58,0
96,0
154,0
240,0
336,0
520,0
672,0
912,0
1152,0
1440,0

2,5
2,7
2,9
3,1
3,7
4,4
4,9
6,8
8,9
10,1
11,4
14,0
15,8
18,1
19,4
22,2

9
12
16
24
33
42
65
110
175
260
380
580
770
1105
1351
1632

Cross-sections 0,5, 0,75 and 1,0 mm2 are not included in the
harmonisation standard and as such, without HAR.
The mectric size is the leading size.
Specification:

Please complete the Part No.


when ordering with the following ref. number:

0 = Cu bare
1 = Cu tinned

1015 See list overview


Specification
Colour

00 black
01 blue
02 brown
03 red
04 white
05 grey
06 violet
07 pink
08 orange
09 yellow
10 green

11 beige
12 darkblue
13 blackgreen
14 blackred
15 blackwhite
16 blueblack
17 bluegreen
18 bluered
19 bluewhite
20 brownblack
21 browngreen

22 brownwhite
23 yellowblack
24 yellowred
25 yellowwhite
26 greenblack
27 greenwhite
28 violetblack
29 violetyellow
30 violetwhite
31 orangeblack
32 orangewhite

ConCab kabel connects the world

33 redblack
34 redyellow
35 redwhite
36 whiteblack
37 whiteblue
38 whitebrown
39 whitered
40 greyblack
50 transparent
99 green/yellow

503

CC-single core PUR-390


Halogen-free, cold resistant single core, 1 kV
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 390 PUR 1 kV

Technical data
Rated voltage:
1000 V

Test voltage:
3000 V

Conductor stranding:

The CC-single core PUR-390 is suitable for


installation purposes requiring zero halogen and
resistant to mechanical stress. The
insulation is extensively resistant to
to oil, fat, acid and lye.

fine copper strands


acc. to DIN VDE 0295, class 5

Construction
Bare fine strands of copper wire, PUR core insulation,
cold-resistant und flame retardant (acc. to DIN VDE
0482, part 265-2-1 resp. EN 50265-2-1
and IEC 60332-1).
Single colour and green/yellow.

504

ConCab kabel connects the world

Insulation resistance:

min. 10 MOhm X km

Temperature range:
-40C to +80C

Bending radius:

10 X core diameter

Approvals:

acc. to DIN VDE 0281

Part-No.

390 0005 ...


390 0007 ...
390 0010 ...
390 0015 ...
390 0025 ...
390 0040 ...
390 0060 ...
390 0100 ...
390 0160 ...
390 0250 ...
390 0350 ...
390 0500 ...
390 0700 ...
390 0950 ...
390 1200 ...
390 1500 ...

Specification:

Crosssection

0,50
0,75
1,0
1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0

Copper
weight

Weight

kg/km

Outer
diameter
approx.
mm

4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0

2,2
2,4
2,6
3,1
3,7
4,4
5,2
6,8
7,8
10,2
11,6
13,2
15,5
17,8
19,4
22,3

8
11
13
19
32
45
65
115
178
250
335
500
690
915
1060
1370

kg/km

Please complete the Part No. 390.


when ordering with the following ref. number:

390 Cross-section
Specification
Colour
0 = Cu bare
1 = Cu tinned
00 black
01 blue
02 brown
03 red

04 white
05 grey
06 violet
07 pink

08 orange
09 yellow
10 green

11 beige
12 darkblue
99 green/yellow

Example:
390 0005 1 00 = 0,50mm, Cu tinned, colour black

ConCab kabel connects the world

505

CC-halogen-free single core


H05Z-K-871
H07Z-K-871
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 871 H07Z-K

Technical data
Rated voltage:

H05Z-K:
300/500 V
H07Z-K:
450/750 V
protected, fixed installation
0,6/1 kV (H07Z-K)

Test voltage:

H05Z-K: 2000 V
H07Z-K: 2500 V

fine copper strands


acc. to DIN VDE 0295, class 5

Construction

8 X core diameter

Bare or tinned, fine strands of copper wire, crosslinked polyolefine core insulation.
Single colour and green/yellow.

506

Conductor stranding:

The CC-halogen-free single core


H05Z-K-871 and H07Z-K-871 exude little smoke and
corrosive gases in the event of fire. They are ideal for
installation purposes in dry rooms for wiring lights
and appliances in buildings that demand a high
standard of protection for humans and goods.

Temperature range:
-40C to +90C

Bending radius:

Approvals:

acc. to DIN VDE 0282, part 9


HD 22.9 S2

ConCab kabel connects the world

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

2,1 - 2,6
2,2 - 2,8
2,4 - 2,9

9
13
15

2,8 - 3,9
3,4 - 4,3
3,9 - 4,9
4,4 - 5,5
5,7 - 7,1
6,7 - 8,4
8,4 - 10,6
9,7 - 12,1
11,5 - 14,4
13,2 - 16,6
15,1 - 18,8
16,7 - 20,9
18,6 - 23,3
20,6 - 25,8
23,5 - 29,4

21
34
47
72
120
190
290
400
550
770
1010
1210
1500
1850
2450

kg/km

H05Z-K
871 0005 ...
871 0007 ...
871 0010 ...

0,50
0,75
1,0

4,8
7,2
9,6
H07Z-K

871 0015 ...


871 0025 ...
871 0040 ...
871 0060 ...
871 0100 ...
871 0160 ...
871 0250 ...
871 0350 ...
871 0500 ...
871 0700 ...
871 0950 ...
871 1200 ...
871 1500 ...
871 1850 ...
871 2400 ...

Specification:

1,5
2,5
4,0
6,0
10,0
16,0
25,0
35,0
50,0
70,0
95,0
120,0
150,0
185,0
240,0

14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

Please complete the Part No. 871...


when ordering with the following ref. number:

871 Cross-section
Specification
Colour
0 = Cu bare
1 = Cu tinned
00 black
01 blue
02 brown
03 red

04 white
05 grey
06 violet
07 pink

08 orange
09 yellow
10 green

11 beige
12 darkblue
99 green/yellow

Example:
871 0005 1 00 = 0,50mm, Cu tinned, colour black

ConCab kabel connects the world

507

CC-earthing cable ESY-356 and ESUY-357


X00V3-D-354
Safety earthing cable
Conforms to the EU low-voltage guideline 73/23/EEC

ConCab kabel Mainhardt 357 ESUY

Technical data
Power rating:

refer to DIN VDE 0103, 0105

Test voltage:

ESY/ESUY: 2000 V
X00V3-D: 1000V

Conductor stranding:
ESY:

The CC-earthing cable ESY-356, ESUY-357 and


X00V3-D is applied as safety earthing rope
during repair work for earthing current carrying parts
in power installations of power supply stations and
railway systems. Its high flexibility makes it ideal for
equipotential bonding in all kinds of machines and
even EDV installations.

bare, superfine copper strands


wire diameter with 0,20 mm

Construction

X00V3-D:
bare, superfine copper strands
wire diameter with 0,20 mm

ESY:
Bare, superfine strands of copper wire,
PVC core insulation. Colour transparent.

Insulation resistance:

ESUY:
Bare, superfine strands of copper wire,
braiding of bare, superfine strands of copper wire.
PVC core insulation. Colour transparent

ESY/ESUY: -5C to +70C


X00V3-D: -25C to +55C

X00V3-D:
Bare, fine strands of copper wire, cold-resistant
PVC-based core insulation. Colour transparent.

508

ESUY:

bare, superfine copper strands


wire diameter at 16 mm2 0,07 mm
wire diameter from 25 mm2 0,10 mm

ConCab kabel connects the world

min. 20 MOhm X km

Temperature range:

Bending radius:

12 X cable diameter

Approvals:

acc. to DIN VDE 0683

Part-No.

Crosssection

Copper
weight
kg/km

Outer
diameter
approx.
mm

Weight

Part-No.

Crosssection

kg/km

kg/km

ESY
356 0160
356 0250
356 0350
356 0500
356 0700
356 0950
356 1200
356 1500

16
25
35
50
70
95
120
150

155
240
336
480
672
912
1152
1440

16
25
35
50
70
95
120
150
185
240

194
280
415
585
820
1090
1360
1650
2150
2750

Outer
diameter
approx.
mm

Weight

9,2
10,6
12.7
14,5
17,3
19,9
21,5
24,1
27,5
31,0

235
345
485
670
905
1220
1506
1940
2390
3092

8,1
9,5
11,0
13,2
15,8
18,3

223
330
455
648
913
1234

kg / km

ESUY tinned
8,6
10,1
12,6
14,1
17,3
19,6
22,9
25,5

190
275
395
580
815
1085
1325
1685

9,2
10,6
12.7
14,5
17,3
19,9
21,5
24,1
27,5
31,0

235
345
485
670
905
1220
1506
1940
2390
3092

8,6
10,1
12,6
14,1
17,3
19,6
22,9
25,5

190
275
395
580
815
1085
1325
1685

ESUY
357 0160
357 0250
357 0350
357 0500
357 0700
357 0950
357 1200
357 1500
357 1850
357 2400

Copper
weight

357 0161
357 0251
357 0351
357 0501
357 0701
357 0951
357 1201
357 1501
357 1851
357 2401

16
25
35
50
70
95
120
150
185
240

194
280
415
585
820
1090
1360
1650
2150
2750
X00V3-D*

354 0160
354 0250
354 0350
354 5000
354 0700
354 0950

16
25
35
50
70
95

154
240
336
480
672
912

*X00V3-D in accordance to <HAR>

ESY tinned
356 0161
356 0251
356 0351
356 0501
356 0701
356 0951
356 1201
356 1501

16
25
35
50
70
95
120
150

155
240
336
480
672
912
1152
1440

ConCab kabel connects the world

509

510

Content
Core identification :
Insulation classes acc. to VDE 0530:
Conductor resistance:
Power rating :
Comparison of former VDE-cables to harmonized cables:
Core designation for harmonized cables:
Abbreviation of power cables:
Abbrevation of telecommunication cables:
Abbrevation for fibre optic cables:
International HAR identification:
Important VDE approvals:
International Institutes (abbreviations):
Conductor stranding acc. to VDE 0295:
Conductor dimensions acc. to AWG:
UL Styles for single core:
UL Styles for cables:
Flame tests acc. to UL/CSA:
Anglo-American measuring units:
Rated-, operating- and test voltage:
Electrotechnical formulas:
Permitted bending radius acc. to VDE regulations:
Drum sizes:
KTG cable drums and capacity:
Capacity of KTG cable drums in metres:
Chemical and physical characteristics of insulation and sheath materials:
Mounting instructions for high flexible cables:
Installation guide for crane cables:
Installation instructions for lift control cables:
Calculation of metal surcharge price:
Index:
European Directives WEEE, RoHS, ElektroG & Reach:
Spiral cable request sheet
Special cable request sheet
ConCab kabel gmbh General Conditions of Sale:

ConCab kabel connects the world

Page
512
516
517
518
519
520
521
522
523
524
525
526
527
528
529
532
538
539
540
541
542
543
544
545
546
548
550
551
552
553
556
557
558
559
511

According to DIN 47 100


23 whitered
24 brownred
25 whiteblack
26 brownblack
27 greygreen
28 yellowgrey
29 pinkgreen
30 yellowpink
31 greenblue
32 yellowblue
33 greenred

34 yellowred
35 greenblack
36 yellowblack
37 greyblue
38 pinkblue
39 greyred
40 pinkred
41 greyblack
42 pinkblack
43 blueblack
44 redblack

For more than 44 cores, there


is no DIN colour code
available - colours repeat starting
at 45. The first colour describes
the base colour of the core
insulation; the second colour
describes the colour imprinted
on the insulation in ring form.

12 redblue
13 whitegreen
14 browngreen
15 whiteyellow
16 yellowbrown
17 whitegrey
18 greybrown
19 whitepink
20 pinkbrown
21 whiteblue
22 brownblue

lg

1 white
2 brown
3 green
4 yellow
5 grey
6 pink
7 blue
8 red
9 black
10 violet
11 greypink

bh

Core Identification

15 whiteyellow
16 yellowbrown
17 whitegrey
18 greybrown
19 whitepink
20 pinkbrown
21 whiteblue
22 brownblue
23 whitered
24 brownred
25 whiteblack
26 brownblack
27 greygreen
28 yellowgrey

nC
a

1 white
2 brown
3 green
4 yellow
5 grey
6 pink
7 blue
8 red
9 black
10 violet
11 greypink
12 redblue
13 whitegreen
14 browngreen

ka
be

According to* DIN 47 100 without colour repetition


29 pinkgreen
30 yellowpink
31 greenblue
32 yellowblue
33 greenred
34 yellowred
35 greenblack
36 yellowblack
37 greyblue
38 pinkblue
39 greyred
40 pinkred
41 greyblack
42 pinkblack

43 blueblack
44 redblack
45 whitebrownblack*
46 yellowgreenblack*
47 greypinkblack*
48 redblueblack*
49 whitegreenblack*
50 browngreenblack*
51 whiteyellowblack*
52 yellowbrownblack*
53 whitegreyblack*
54 greybrownblack*
55 whitepinkblack*
56 pinkbrownblack*

Co

* divergence to DIN: from 45th core without colour repetition.

512

ConCab kabel connects the world

57 whiteblueblack*
58 brownblueblack*
59 whiteredblack*
60 brownredblack*
61 blackwhite*

cable with green/yellow conductor


-gnye / bu / bn
bu / bn / bk
gnye / bn / bk / gy
gnye / bu / bn / bk
gnye / bu / bn / bk / gy
gnye / cores black with
consecutive white numbering,
starting at the inner layer with 1,
gnye in the outer layer

cable without green/yellow conductor


bu / bn
bn / bk / gy

bu / bn / bk / gy / bk
cores black with consecutive
white numbering, starting at
at the inner layer with 1

bu / bn / bk / gy

bu / bn / bk / gy / bk
cores black with consecutive
white numbering, starting at
at the inner layer with 1

Co
n

Ca
b

a* only for special application

bu / bn / bk / gy

gm

flexible application
No. of cores
2
3
3a*
4
4a*
5
6 and more

cable without green/yellow conductor


(abbreviation O)
bu / bn
bn / bk / gy

be
l

2
3
3a*
4
4a*
5
6 and more

cable with green/yellow conductor


(abbreviation J)
-gnye / bu / bn
bu / bn / bk
gnye / bn / bk / gy
gnye / bu / bn / bk
gnye / bu / bn / bk / gy
gnye / cores black with
consecutive white numbering,
starting at the inner layer with 1,
green/yellow in the outer layer

ka

fixed installation
No. of cores

bh

According to VDE 0293-308 HD 308.S2 2003-01

513

Core identification

68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101

orange-white-black
transparent-white-black
beige-white-black
brown-white-blue
grey-white-blue
red-white-blue
violet-white-blue
pink-white-blue
orange-white-blue
transparent-white-blue
beige-white-blue
grey-white-brown
red-white-brown
violet-white-brown
pink-white-brown
orange-white-brown
transparent-white-brown
beige-white-brown
red-white-grey
violet-white-grey
pink-white-grey
orange-white-grey
transparent-white-grey
beige-white-grey
blue-white-red
brown-white-red
violet-white-red
pink-white-red
orange-white-red
brown-white-violet
orange-white-violet
brown-black-blue
grey-black-blue
red-black-blue

lg

pink-blue
orange-blue
transparent-blue
beige-blue
grey-brown
red-brown
violet-brown
pink-brown
orange-brown
transparent-brown
beige-brown
red-grey
violet-grey
pink-grey
orange-grey
transparent-grey
beige-grey
orange-red
transparent-red
beige-red
pink-violet
orange-violet
transparent-violet
beige-violet
transparent-pink
beige-pink
transparent-orange
beige-orange
blue-white-black
brown-white-black
grey-white black
red-white-black
violet-white-black
pink-white-black

ka
be

34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67

greenyellow
white
black
blue
brown
grey
red
violet
pink
orange
transparent
beige
black-white
blue-white
brown-white
grey-white
red-white
violet-white
pink-white
orange-white
transparent-white
beige-white
blue-black
brown-black
grey-black
red-black
violet-black
pink-black
orange-black
transparent-black
beige-black
brown-blue
grey-blue
red-blue

Co

nC
a

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

Counting from inside to outside. The protective conductor (green yellow) is the last core.
For cables up to 5 cores inclusive, cores are identified by VDE 0293 colour code for
connecting mobile electrical equipment.

514

bh

According to CC-colour code

ConCab kabel connects the world

bh

According to VDE 0815 and 0816 for telephone indoor and outdoor cables
J-YY / A-2YF(L)2Y / A-2Y(L)2Y

J-Y(St)Y
with 2-pair installation cable:
1. pair: a-core red, b-core black
2. pair: a-core white, b-core yellow

identification with black rings


a-core
b-core

standard 2

witho.ring

with 4- and more paired installation cables:


a-core with 1.pair every layer red, with all other pairs
white

a-core
b-core

Basic colours of the core insulation of the 5 star quad of a bundle

b-core blue, yellow, brown, black in continious


sequence. Counting from outside to inside.

quad 4 yellow
quad 5 white

el

quad 1 red
quad 2 green
quad 3 grey

gm

standard 1

The numerical bundles are marked with red spirals.

ka
b

According to VDE 0815 for electronic cables JE-LiYCY and JE-Y(St)Y


The bundles are identified by the colours of the ring
on the core insulation sheath and the sequence of the colour
rings in groups. The ring groups have an interspace
of 60 mm.

Identification
The core pairs are identified by the basic colours of the
insulation sheath which repeat themselves in the same
sequence in every bundle.

Ring colour
pink
pink
pink
pink

Co
n

Bundle
1
2
3
4

Paar
a-core
b-core

1
blue
red

2
3
4
grey green white
yellow brown black

Cables with more than 12 bundles, the 13th and


subsequent bundles have coloured spirals.

Ca
b

Basic colours
of pairs

Ring group

Counting of the bundles begins from the most inner


layer.

Bundle spiral

Bundle
13
14
15
16

Ring colour
pink
pink
pink
pink

17
18
19
20

orange
orange
orange
orange

5
6
7
8

orange
orange
orange
orange

9
10
11
12

violet
violet
violet
violet

Ring group

Bundle spiral
blue
blue
blue
blue
red
red
red
red

515

105C

130C

155C

180C

>180C

Co
nC

516

PVC, rubber, PUR,


neoprene,
halogen-free copolymers

PVC

CC-flat, round and CC-control cables


CC-rubber cables
CC-PUR cables
CC-halogen-free cables
CC-single cores
CC-Therm 105C
CC-UL/CSA single cores

EVA, ETFE

CC-special single cores and cables

polymer mixture on
EVA-basis

CC-Therm 150C
CC-Therm 150C
CC-Therm 150 C single cores

silicone

CC-silicone cables
CC-silicone single cores

FEP, PTFE

CC-FEP/PTFE single cores


CC-FEP/PTFE multicore cables
CC-Nonflam single cores 450C
CC-Nonflam multicore cables 450C

ab

A (E)

CC-cable types

gm

90C

Insulation material

el

max. permitted
const. temperature

ka
b

Insulation class

bh

Insulation classes according to VDE 0530

impregnated glass fibre


and mineral fibre

ConCab kabel connects the world

bh

Conductor resistance

36,7
24,8
18,2
12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607

p 250
p 142
p 82
p 59
40,1
26,7
20,0
13,7
8,21
5,09
3,39
1,95
1,24
0,795
0,565
0,393
0,277
0,210
0,164
0,132
0,108
0,0817
0,0654

36,0
24,5
18,1
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601

Co
n

Ca
b

ka
b

0,05
0,14
0,25
0,34
0,5
0,75
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

conductor resistance at 20 C
for 1 km in q (average max. value)
tinned wires
bare wires
class 1 + 2
class 5 + 6
class 1 + 2
class 5 + 6

p 243
p 138
p 79
p 57
39,0
26,0
19,5
13,3
7,98
4,95
3,30
1,91
1,21
0,780
0,554
0,386
0,272
0,206
0,161
0,129
0,106
0,0801
0,0641

el

Nominalcrosssection
mm2

gm

Conductor resistance for fine conductors (extract from VDE 0295 and in accordance with
international regulation IEC 60228).
Decisive for the construction of the conductor is the max. x of the individual wires and
the max. conductor resistance.

ConCab kabel connects the world

517

Power rating

Admissible loadability of flexible cables with a rated voltage of up


to 1000 V at an ambient temperature of 30 C (extract from VDE
0298 part 4, VDE 0100 part 523 as well as
VDE 0891).
NominalGroup 1
Group 2
Group 3
crossLoadLoadLoadsection
ability
fuse ability
fuse
ability
fuse
max. A A
max. A
A
max. A.
A
mm2

Group 2
Multicore cables e.g.,
control cables

0,8
1,5
3,0
4,5
7,0
9,0
11
15
20
25
33
45
61
83
103
132
165
197
235
-----

------6
10
16
20
25
35
50
63
80
100
125
160
200
-----

ab

ka
b

Group 3
Single core cables, laid open in air
e.g,: wiring in switch cabinets

0,05
0,14
0,25
0,34
0,50
0,75
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Co
nC

Conversion factors for changing


ambient temperatures acc. to
VDE 0298, part 4

518

1
2
4
6
9
12
15
18
26
34
44
61
82
108
135
168
207
250
292
335
382
453
523

-----6
10
10
20
25
35
50
63
80
100
125
160
200
250
250
315
400
400

el

Group 1
single core cables in duct,
e.g., H05V...

gm

bh

Current carrying capacity

1,5
3
5
8
12
15
19
24
32
42
54
73
98
129
158
198
245
292
344
391
448
528
608

Insulation material

PVC / PUR / TPE

permissible operating temp.

70C / 80C

Ambient temperature C

Power rating factor

10
15
20
25
30
35
40
45
50
55
60

1,22
1,17
1,12
1,06
1,0
0,94
0,87
0,79
0,71
0,61
0,50

-----10
10
20
25
35
50
63
80
100
125
160
200
250
315
315
400
400
500

Comparison of former VDE-cables (VDE 0250)


to harmonized cables (VDE 0281 and VDE 0282)
PVC cables
old abbreviation new abbreviation acc. to
acc. to VDE 0250 acc. to VDE 0281 VDE 0281

hook-up wire 300/500V


solid wire
fine wires

NYFA
NYFAF

H05V- U
H05V-K

part 3
part 3

hook-up wire 450/750V


solid wire
fine wires

NYA
NYAF

H07V-U
H07V-K

part 3
part 3

Light twin cables

NLYZ

H03VH-Y

part 5

Twin cables

NYZ

H03VH-H

part 5

Flexible cables 300/300V


round
flat

NYLHY round
NYLHY flat

H03VV-F
H03VVH2-F

part 5
part 5

Flexible cables 300/500V


round
flat

NYMHY round
NYMHY flat

H05VV-F
H05VVH2-F

part 5
part 5

hook-up wire 90C


solid wire
fine wires

NYFAw
NYFAFw

H05V2-U
H05V2-K

part 7
part 7

Ridge cables for lights

NYIFY

H03VH7H-F

part 11

Flat cables

NYFLY
NYFLY

H05VVH6-F
H07VVH6-F

part 403
part 404

ka

be
l

gm

bh

Identification
acc. to HAR

Ca
b

Rubber cables

old abbreviation new abbreviation acc. to


acc. to VDE 0250 acc. to VDE 0282 VDE 0282

Silicone cables
Flexible cord
Flexible rubber 300/500V
Flexible rubber 300/500V
Flexible rubber 450/750V
Welding cables

N2GAFU
NSA
NLH
NMHU
NSHU, NMHU
NSLFFU

H05SJ-K
H03RT-F
H05RR-F
H05RN-F
H07RN-F
H01N2-D
H01N2-E

part 3
part 4
part 4
part 4
part 4
part 6

N4GA
N4GAF
NGMH11Y

H07G-U
H07G-K
H05BQ-F
H07BQ-F
H05RND3-F
H07RND3-F
H05RC4ND3-F
H07RC4ND3-F

part 7
part 7
part 10

Co
n

Identification
acc. to HAR

Core conductor (110C)


solid wire
fine wires
EPR insulated high-voltage
cable with PUR sheath
Lift control cables

NFLG
NFLGC

part 807
part 807

519

Code designation for


harmonized cables
ABBREVIATION FOR DESIGN
Example: Oil resisting shielded PVC-control cable 27 G 0,75mm2 acc. to VDE 0281, part 3

H 05 V V C4 V5 C4

INNER SHEATH
(coding for sheath material)

ka
b

CONSTRUCTION ITEMS
C4
Shield/braid
Q4
(PA) Additional polyamide core sheath
T
Additional textile braiding over twisted cores

el

INSULATION MATERIAL
B
(EPR) Ethylene propylene rubber
G
(EVA) Ethylene vinyl acetate copolymer
N2
(CR) Chloroprene rubber
R
(NR,SR) Natural synthetic rubber mixture
S
(SiR) Silicone rubber
V
(PVC) Polyvinyl chloride
V2
(PVC) Heat-resistant polyvinyl chloride
V3
(PVC) Cold-resistant polyvinyl chloride
V4
(PVC) Cross-linked polyvinyl chloride
Z
(TPE-0) Cross-linked polyolefine

gm

RATED VOLTAGE U
01
100V
03
300/300V
05
300/500V
07
450/750V

ab

SHEATH MATERIAL
B
(EPR) Ethylene propylene rubber
G
(EVA) Ethylene vinyl acetate copolymer
J
Glass-fibre braiding
N
(CR) Chloroprene rubber
N4
(CR) Heat-resistant chloroprene rubber
Q
(PUR) Polyurethane
R
(NR or SR) Natural or synthetic rubber mixture
T
Textile braiding
V
(PVC) Polyvinyl chloride
V2
(PVC) Heat-resistant polyvinyl chloride,
V4
(PVC) Cross-linked polyvinyl chloride,
V5
(PVC) Oil resisting polyvinyl chloride

Co
nC

SPECIAL CONSTRUCTION FEATURES


D3
Strain relief element (supporting element)
D5
Centre core (non supporting element)
FM
Telecommunication cores integrated in power cables
H
Flat, separable twin cables
H2
Flat non-seperable flexible two-core sheathed cable
H6
Flat non-seperable multi-core sheathed cable
H7
Double layer insulation sheath
H8
Spiral cables
TYPES OF CONDUCTOR
D
Fine stranded for welding cables
E
Superfine stranded for welding cables
F
Fine stranded, class 5
H
Superfine stranded, class 6
K
Fine stranded (fixed installation)
R
Multiple stranded, round class 2
U
Solid wire, round class 1
Y
Tinsel wire
NO. OF CORES

PROTECTIVE CONDUCTOR
G
With protective conductor
X
Without protective conductor
CONDUCTOR NOMINAL CROSS-SECTION in mm2

520

27 G 0,75

bh

IDENTIFICATION FEATURE
A
Recognised national types
H
Harmonized standard types

Power cables with synthetic materials and sheaths

gm

be
l

F
F
FE
R
GB
HX
Y
2Y

Aluminium conductor
Insulation out of polyvinyl chloride (PVC)
Insulation out of thermo plastic polyethylene (PE)
Insulation out of cross-linked polyvinyl chloride (XLPVC)
Insulation out of cross-linked polyethylene (XLPE)
Field limiting conductive layers over the conductor and insulation
Insulation out of cross-linked halogen-free polymer mixture
Concentric conductor out of copper
Concentric conductor out of copper in waveconal formation
Concentric conductor with multicore cables over each individual core
Copper shield
With multiwired cables there are field limiting, conductive layers
over the conductor and the insulation as well as a copper shield over
each individual core (abbreviation H omitted here)
Overhead conductor (DIN VDE 0274)
Armouring out of galvanized flat steel wires
Insulation retained for a limited time
Armouring out of galvanized round steel wires
Counter-twist out of galvanized steel band
Sheath out of cross-linked halogen-free polymer mixture
Inner and/or outer sheath out of polyvinyl chloride (PVC)
Outer sheath out of polyethylene (PE)

ka

A
Y
2Y
X
2X
H
HX
C
CW
CE
S
SE

bh

Abbreviation for power cables

Abbreviation of conductor shapes

Conductor with circular cross-section


Conductor with sector-pattern cross-section
Solid conductor
Multiple stranded conductor
Solid conductor, circular cross-section
Multiple stranded conductor, circular cross-section
Solid conductor, sector-pattern cross-section
Multiple stranded conductor, sector-pattern cross-section
Multiple stranded conductor, oval cross-section
Hollow conductor
Compact conductor

Ca
b

Co
n

R
S
E
M
RE
RM
SE
SM
OM
H
/V

ConCab kabel connects the world

521

Abbreviation for telecommunication cables

bh

gm

el

ka
b

Co
nC

S
FE
M
Mz
C
(C)
(K)
L
LD
(L)2Y
F(L)2Y
W
B
C
Q
(St)
(Z)
E
T
(Zg)
P
Y
Yv
2Y
2Yv
02Y
4Y
5Y
6Y
7Y
H
Bd
DM
Lg
F
St
St I
St III
PiMF
S
TF

Outdoor cable
Outdoor cable with lightning protection requirements
Outdoor cable with induction protection requirements
Mining cable
Mining cable with induction protection requirements
Installation cable
Installation cable for industrial electronics
Flexible cables for telecommunication systems
Cables with stranded wire conductor for heavy mechanical stress in
telecommunication systems.
Switchboard cable for telephone systems
Cable with insulation performance requirements against flames
Lead sheath
Hardened lead sheath
Shield out of copper wire braiding
Shield out of copper wire braiding over pair
Shield out of copper band
Smooth aluminium sheath
Aluminium corrogated sheath
Layered sheath
Centre core with petroleum jelly filling and layered sheath
Steel corrogated sheath
Armouring
Protective covering out of jute and viscous mass
Armouring out of steel wire braid
Shield out of metal band or plastic laminated metal band
Steel wire braiding over PVC inner sheath
Earth layer with embedded plastic band
Strain relief element
Strain relief out of bundled glass-fibre threads embedded in sheath
Insulation out of paper
Insulation, inside or outside sheath out of polyvinyl chloride (PVC)
Reinforced outer sheath out of PVC
Insulation, inside or outside sheath out of polyethylene (PE)
Reinforced outer sheath out of PE
Insulation out of cellular-PE
Insulation, inside or outside sheath out of polyamide (PA)
Insulation, inside or outside sheath out of polytetrafluorethylene (PTFE)
Insulation, inside or outside sheath out of perfluorethylene propylene (FEP)
Insulation, inside or outside sheath out of ethylene tetrafluorethylene (ETFE)
Insulation, inside or outside sheath out of halogen-free material
Bundle layers
Dieselhorst-Martin-quad
Layered twisting
Star quad in railway telecommunication cable
Star quad mit phantom circuit
Star quad semidirect line (telecommunication cable)
Star quad in local cable
Shielded pair (pair in metal foil)
Railway signal cable
Star quad for carrier frequency technology

ab

A
AB
AJ
G
GJ
J
JE
L

522

bh

Abbreviation for fibre optic cables

Cable construction

F
V
H
W
B
D

gm

be
l

Fibre without buffer


Tight buffer fibre
Single fibre loose buffer, unfilled
Single fibre loose buffer, filled
Multiple fibre loose buffer, unfilled
Multiple fibre loose buffer, filled

Ca
b

Cores

Outdoor cable
Seperable outdoor cable
Seperable indoor cable
Indoor cable
Metal element in cable centre
Filling up the twisted hollow space of the cable centre with petroleum jelly
Filling up the twisted hollow space of the cable centre with swelling medium
PVC sheath
PUR sheath
Halogen-free sheath
PE sheath
Layered sheath
PE sheath with plastic blocking layer
PE sheath with non-metal strain relief elements
Layered sheath with non-metal strain relief elements
PE sheath with plastic blocking layer and non-metal strain relief elements
Armouring
Armouring with PVC protective sheath
Armouring with PE protective sheath

ka

A
AT
IT
I
S
F
Q
Y
11Y
H
2Y
(L)2Y
(D)2Y
(ZN)2Y
(L)(ZN)2Y
(D)(ZN)2Y
B
BY
B2Y

Fibre design

Co
n

E
G
S
Q
K
P

Single-mode fibre
Gradient fibre (quartz core /quartz cladding)
Step index fibre (quartz / quartz cladding)
Quasi-step index fibre (quartz core / quartz cladding)
Step index fibre (quartz core / plastic cladding)
Step index quartz polymer fibre (plastic core/ plastic cladding)

ConCab kabel connects the world

523

Country

Identification

National testing centre

Abbreviation

CEBEC <HAR>

Comit Electrotechnique Belge

CEBEC

Denmark

<DEMKO> <HAR>

DEMKO

Germany

<VDE> <HAR>

Danmarks Elektriske Materialkontroll


Verband Deutscher Elektrotechniker e.V.
VDE Prf- und Zertifizierungsinstitut

Finland

SETI <HAR>

Elektiska Inspektorater

SETI

France

USE <HAR>

Greece

ELOT <HAR>

Great Britain

BASEC <HAR>

Italy
Ireland

ka
b

VDE

Union Technique de lElektricit

UTE

Hellenic Organization for Standardization

ELOT

British Approvals Service for Cables

BASEC

IEMMEQU <HAR>

Instituto Italiano de Marchio Qualit

IMQ

<NSAI> <HAR>

NSAI

KEMA-KEUR <HAR>

National Standards Authority of Ireland


N.V. tot Keuring van Elektrotechnische
Materalien

KEMA

NEMKO <HAR>

Norges Elektriske Materielkontroll

NEMKO

ab

Co
nC

Norway

el

Belgium

Netherland

524

Tracer thread
bk rd ye
cm

gm

In respect of the CENELEC agreement, an identification for harmonized cables and cables was
made for the individual member states. This is based on the specification of the producer country together with the <HAR> Logo. Furthermore harmonized cables must have an identification
colour tracer thread in the colours black, red and yellow whereby the length of the individual
colours is defined precisely.

bh

International HAR identification

Austria

<VE> <HAR>

sterreichischer Verband for Elektrotechnik

VE

Portugal

<IPQ> <HAR>

Instituto Portugus da Qualidade

IPQ

Sweden

SEMKO <HAR>

Svenska Elektriska Materielkontrollanstalten

SEMKO

Switzerland

SEV <HAR>

SEV

Spain

AENOR <HAR>

Schweizerischer Elektrotechnischer Verein


Asociacin Espaola de Normalizacin
y Certificacin

ConCab kabel connects the world

AENOR

bh

Important VDE approvals

Topic

DIN VDE 0100 ff

Erection of power installations with nominal voltages up to 1000V

DIN VDE 0207 ff

Insulating and sheathing compounds for cables and flexible cords

DIN VDE 0245 ff

Cables, wires and flexible cords for power installation

DIN VDE 0250 ff

Cables, wires and flexible cords for power installation

DIN VDE 0276 ff

Power cables

DIN VDE 0281 ff

PVC-cables, wires and flexible cords for power installations

DIN VDE 0282 ff

Rubber insulated cables

DIN VDE 0293 ff

Identification of cores in cables and flexible cords used in power installations with

be
l

gm

Standard

nominal voltages up to 1000V

Conductors for cables , wires and flexible cords for power installation

DIN VDE 0298 ff

Application of cables and flexible cords in power installations

DIN VDE 0472 ff

Testing of cables, wires and flexible cords

DIN VDE 0482

General testing procedure of behaviour of cables and flexible cords in the event of fire

DIN VDE 0800 ff

Telecommunication technology general terms

DIN VDE 0812

Equipment wires and stranded equipment wires for telecommunications systems and data

ka

DIN VDE 0295

Ca
b

processing systems

Switchboard cables for telecommunication and data processing systems

DIN VDE 0814

Cords for telecommunication and data processing

DIN VDE 0815

Wiring cables for telecommunication and data processing

DIN VDE 0816 ff

External cables for telecommunication and data processing

DIN VDE 0888 ff

Fibre optic cables

Co
n

DIN VDE 0813

ConCab kabel connects the world

525

International Institutes (abbreviations)

CEI
CEMP
CENELEC
CNET
CNOMO

CSA
CSTB
DEMKO
DIN
DKE

Co
nC

EN
ETSI
FAR
FTZ

GOST
HD
HN
IEC

526

ISO
KEMA
LCIE
MIL
NEC
NEMA

bh

ISDN

CEE

IEEE

nstitution of lectrical ngineers


(Great Britain)
nstitute of lectrical and lectronics ngineers
US Association of Electro and Electronic Engineers
ntegrated ervices igital etwork
(International)
nternational rganization for tandardization
(International)
euring van lektrotechnische ateralien
(Netherland)
aboratoire entral des ndustries lectriques
(France)
ilitary Specification (USA)
ational lectrical ode (USA)
ational lectrical anufacturers ssociation
(USA)
orges lektriske ateriellkontroll
(Norway)
derlands ormalisatie-Instituut
(Netherland)
ormes ranaises (France)
ormes ranaises lass C (France)
sterreichischer erband fr lektrotechnik
(Austria)
ociety of utomotive ngineers (USA)
venska lektiska ommissionen
(Sweden)
venska lektriska aterielkontrollanstalten
(Sweden)
chweizerischer lektrotechnischer erein
(Switzerland)
chweizerischer ormen erband
(Switzerland)
nderwriters aboratories Inc (USA).
nificazione ationale taliana (Italy)
nion echnique de l lectricit (France)
erein eutscher lektrotechniker e.V.
(Germany)
ereinigung eutscher lektrizittswerke e.V.
(Germany)
entral erband der Deutschen lektroandwerke e.V. (Germany)
entral erband der lektrotechnik- und
Elektronik- ndustrie e.V. (Germany)

lg

BS
BSI
BV
CATV

IEE

NEMKO
NEN

ka
be

ANSI
AS
ASTM

ssociation ranaise de
malisation
(France)
merican ational tandards nstitute (USA)
ustralian tandard (Australia)
merican tandard of esting aterials
(USA)
ritish tandard (UK)
ritish tandard nstitution (UK)
ureau eritas (France)
ommunity ntenna elevision
(International)
International ommission on Rules for
the Approval of lectrical quipment
(International Commission)
ommission lectrotechnique nternationale
(International)
entre d tude des atires lastiques
(France)
omit uropen de ormalisation
Electrotechniques (Europe)
entre ational d tude de lcommunisation
(France)
omit de rmalisationdes
yens
de Production
Commission for standards of tools and machine
tools in the French automobile industry (France)
anadian tandards ssociation (Canada)
entre cientifique et echnique
du timent (France)
anmarks lektriske aterielkontrol
(Denmark)
eutsches nstitut fr ormung (Germany)
eutsche lektrotechnische ommission
im DIN undVDE (Germany)
uropische ormen (European Standards)
uropean elecommunications tandards
nstitute (Europe)
ederal ir egulation(USA)
ernmelde echnisches entralamt
(Germany)
USSR-Standards (USSR)
armonisierungs- okumente (International)
armonisation des ormes (France)
nternational lectrotechnical ommission
(International)

ab

AFNOR

NF
NFC
VE

SAE
SEK

SEMKO
SEV

SNV
UL
UNI
UTE
VDE
VDEW
ZVEH
ZVEI

ConCab kabel connects the world

Multiple
strands
VDE 0295
class 2

Multiple
strands

Fine
strands
VDE 0295
class 5

Superfine
strands
VDE 0295
class 6

mm2

column 1

column 2

column 3

column 4

0,14
0,25
0,34
0,38
0,50
0,75
1,0
1,5
2,5
4,0
6,0
10
16
25
35
50
70
95
120
150
185
240
300
400
500

7 u 0,30
7 u 0,37
7 u 0,43
7 u 0,52
7 u 0,67
7 u 0,85
7 u 1,05
7 u 1,35
7 u 1,70
7 u 2,13
7 u 2,52
19 u 1,83
19 u 2,17
19 u 2,52
37 u 2,03
37 u 2,27
37 u 2,52
61 u 2,24
61 u 2,50
61 u 2,89
61 u 3,23

7 u 0,25
7 u 0,27
7 u 0,30
7 u 0,37
7 u 0,43
7 u 0,52
19 u 0,41
19 u 0,52
19 u 0,64
49 u 0,51
49 u 0,65
84 u 0,62
133 u 0,58
133 u 0,69
189 u 0,69
259 u 0,69
336 u 0,67
392 u 0,69
494 u 0,69
627 u 0,70
790 u 0,70

14 u 0,15
19 u 0,15
12 u 0,20
16 u 0,20
24 u 0,20
32 u 0,20
30 u 0,25
50 u 0,25
56 u 0,30
84 u 0,30
80 u 0,40
128 u 0,40
200 u 0,40
280 u 0,40
400 u 0,40
356 u 0,50
485 u 0,50
614 u 0,50
765 u 0,50
944 u 0,50
1225 u 0,50
1530 u 0,50
2035 u 0,50
1768 u 0,60

18 u 0,1
32 u 0,1
42 u 0,1
21 u 0,15
28 u 0,15
42 u 0,15
56 u 0,15
84 u 0,15
140 u 0,15
224 u 0,15
192 u 0,20
320 u 0,20
512 u 0,20
800 u 0,20
1120 u 0,20
705 u 0,30
990 u 0,30
1340 u 0,30
1690 u 0,30
2123 u 0,30
1470 u 0,40
1905 u 0,40
2385 u 0,40

Crosssection

bh

Conductor stranding acc. to VDE 0295


resp. IEC 60228 (from 0,5mm2)

column 5

18 u 0,1
32 u 0,1
42 u 0,1
48 u 0,1
64 u 0,1
96 u 0,1
128 u 0,1
192 u 0,1
320 u 0,1
512 u 0,1
768 u 0,1
1280 u 0,1
2048 u 0,1
3200 u 0,1

column 6

column 7

36 u 0,07
65 u 0,07
88 u 0,07
100 u 0,07
131 u 0,07
195 u 0,07
260 u 0,07
392 u 0,07
651 u 0,07
1040 u 0,07
1560 u 0,07
2600 u 0,07

72 u 0,05
128 u 0,05
174 u 0,05
194 u 0,05
256 u 0,05
384 u 0,05
512 u 0,05
768 u 0,05
1280 u 0,05

The number of wires indicated in


the column is non binding.
The VDE 0295 only stipulates the max. diameter of the individual wires and the
max. resistance allocated to the cross-section.

ConCab kabel connects the world

527

Conductor dimensions acc. to AWG


(American Wire Gage)
In areas with American influence and in computer technology, the copper wire dimensions are generally
expressed in AWG numbers. The table below shows a comparision between AWG-numbers and metric dimensions.

AWG-solid wires

Co
nC
528

AWG
No.

cross-section
approx. mm2

11,684
10,404
9,266
8,252
7,348
6,543
5,827
5,189
4,620
4,115
3,665
3,268
2,906
2,588
2,304
2,052
1,829
1,628
1,450
1,290
1,151
1,024
0,912
0,813
0,724
0,643
0,574
0,511
0,455
0,404
0,361
0,320
0,287
0,254
0,226
0,203
0,180
0,160
0,142
0,127
0,114
0,102
0,089
0,079

107,2
85,0
67,4
53,5
42,4
33,6
26,7
21,1
16,8
13,3
10,5
8,4
6,6
5,3
4,2
3,3
2,6
2,1
1,65
1,31
1,04
0,82
0,65
0,519
0,412
0,325
0,259
0,205
0,163
0,128
0,102
0,080
0,065
0,051
0,040
0,032
0,025
0,020
0,016
0,013
0,010
0,008
0,006
0,005

gm

4/0
3/0
2/0
1/0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

conductor-x
mm

el

cross-section
approx. mm2
254
203
178
152
127
107,2
85,0
67,6
53,4
42,4
33,6
26,7
21,2
16,8
13,3
10,6
8,35
6,62
5,27
4,15
3,31
2,63
2,08
1,65
1,31
1,04
0,823
0,653
0,519
0,412
0,325
0,259
0,205
0,163
0,128
0,102
0,0804
0,0646
0,0503
0,0400
0,0320
0,0252
0,0200
0,0151
0,0123
0,0100
0,00795

ka
b

conductor-x
mm
20,7
18,9
17,3
16,0
14,6
11,68
10,40
9,27
8,25
7,35
6,54
5,83
5,19
4,62
4,11
3,67
3,26
2,91
2,59
2,30
2,05
1,83
1,63
1,45
1,29
1,15
1,024
0,912
0,812
0,723
0,644
0,573
0,511
0,455
0,405
0,361
0,321
0,288
0,255
0,227
0,202
0,180
0,160
0,143
0,127
0,113
0,101

ab

AWG
No.
500 MCM
400 MCM
350 MCM
300 MCM
250 MCM
4/0
3/0
2/0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

bh

AWG-stranded wires

UL styles for single core

Temperature

Voltage

Style 1002

60

600

30 (0,76) PVC

26...16

Style 1116

80

600

Style 1003

60

300

30 (0,76) PE, FRPE, PVC

26...16

Style 1118

90

300

Style 1007

80

300

15 (0,38) PVC

32...16

Style 1119

90

600

Style 1012

80

600

30 (0,76) PVC

28...9

Style 1120

Style 1013

90

600

30 (0,76) PVC

28...9

Style 1122

Style 1015

105

600

30 (0,76) PVC

28...9

Style 1123

Style 1017

80

600

45 (1,14) PVC

22...8

Style 1124

Style 1019

80

600

60 (1,52) PVC

8...2

Style 1160

Style 1020

80

600

80 (2,05) PVC

Style 1024

90

600

45 (1,14) PVC

Style 1026

90

600

60 (1,52) PVC

Style 1027

90

600

80 (2,05) PVC

Style 1028

105

600

Style 1030

80

Style 1032
Style 1039

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

AWG

bh

AWG

30 (0,76) PVC

30...12

15 (0,38) PVC

26...16

30 (0,76) PVC

26...16

gm

Wall thickness
insulation
mil (mm)

105

600

30-80 (0,76-2,05) PVC

80

300

9 (0,23) SR-PVC

80

300

30 (0,76) PVC

22...20

80

300

30 (0,76) PVC

22...20

60

300

15 (0,38) PVC

26...16
26...9

be
l

Style

30...4/0
30

Style 1161

60

600

30 (0,76) PVC

22...8

Style 1185

80

300

15-80 (0,38-2,05) PVC

30...4/0

8...2

Style 1195

80

300

15 (0,38) SR-PVC

30...14

1...4/0

Style 1208

80

300

13 (0,33) SR-PVC

30...16

45 (1,14) PVC

22...8

Style 1226

80

not specified

8-13 (0,21-0,33) FEP

32...14

1000 AC

30 (0,76) PVC

26...10

Style 1227

105

not specified

8-13 (0,21-0,33) FEP

32...14

90

1000 AC

30 (0,76) PVC

26...10

Style 1233

80

600

60 (1,52) PVC

18...8

80

300

15 (0,38) PVC

26...16

Style 1235

105

600

60 (1,52) PVC

18...8

80

600

60 (1,52) PVC

18...10

Style 1237

80

600

45 (1,14) PVC

26...19

80

300

9 (0,23) SR-PVC

30...16

Style 1239

105

600

45 (1,14) PVC

26...19

80

300

12 (0,31) PVC

30...16

Style 1283

105

600

60 (1,52) PVC

8...2

80

300

15 (0,38) PVC

28

Style 1284

105

600

80-110 (2,0-2,79) PVC 8...1000MCM

60

300

15 (0,38) PE, FRPE, PVC

30...16

Style 1330

200

600

20-45 (0,51-1,14) FEP

30...4/0

Style 1108

80

300

15 (0,38) PVC, FEP, PTFE

30...16

Style 1331

150

600

20-45 (0,51-1,14) FEP

30...4/0

Style 1109

90

300

15 (0,38) PVC, XPVC

26...16

Style 1332

200

300

13 (0,33) FEP

30...10

Style 1110

105

300

15 (0,38) PVC, XPVC

26...16

Style 1113

60

600

30 (0,76) PE, FRPE, PVC

30...16

Style 1115

80

300/600

15 (0,38) PVC

30...16

Style 1061
Style 1095
Style 1099

Co
n

Style 1107

Ca
b

Style 1054

ka

1...4/0

Abbreviation:
FR
=
SR-PVC =
X
=

flame retardant
semi rigid (hardened PVC)
cross-linked by radiation

529

UL styles for single cores


Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

AWG

Style 1333

150

300

13 (0,33) FEP

30...10

Style 1347

80

300

15 (0,38) PVC

Style 1348

60

300

Style 1349

80

Style 1350

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

AWG

Style 1499

90

600

30 (0,76) PVC

26...9

26...16

Style 1500

105

600

30 (0,76) PVC

26...9

15 (0,38) PE, FRPE

26...16

Style 1508

105

30

5,5 (0,14) ETFE

300

15 (0,38) PVC

26...16

Style 1513

80

600

28 (0,71) PE

26...16

Style 1516

Style 1354

60/80

30

>5 (0,13) PE, PP etc.

min. 40

Style 1517

Style 1365

60

300

23 (0,58) PE, FRPE

30...16

Style 1523

Style 1371

105

not specified

36...6

Style 1538

Style 1375

60/80

30

7-150 (0,18-3,8) PE, PPetc. min. 32

Style 1379

60/80

150

Tube 15 (0,38) FRPE

Style 1380

60/80

300

Tube 20 (0,50) FRPE

20...29

Style 1381

60/80

600

Tube 25 (0,63) PE

Style 1382

80

300

Style 1435

80

Style 1436
Style 1437

Style 1439
Style 1477
Style 1478

gm
not specified

5 (0,13) ETFE

36...20

105

not specified

4 (0,10) ETFE

36...20

105

not specified

6 (0,16) ETFE

32...20

105

not specified

5 (0,13) ETFE

32...20

105

125

5,5-20 (0,14-0,51) FEP

el

105

36...6

80

300

30 (0,76) PE, FRPE

min. 30

Style 1546

60

300

18 (0,45) PE, FRPE

30...20

Style 1558

125

not specified

4 (0,10) ETFE

32...20

20...29

Style 1568

80

150

9 (0,23) PVC

30...16

Tube 40 (1,01) PE

20...29

Style 1569

80, 90, 105

300

15 (0,38) PVC

30...10

300

15 (0,38) PE, FRPE

30...16

Style 1577

200

not specified

12 (0,30) FEP

32...16

80

300

30 (0,76) PE, FRPE

27...16

Style 1581

80

300

15 (0,38) PVC

15...10

80

300

60 (1,53) PE

22

Style 1582

80

300

30 (0,76) PVC

30...9

ka
b

20...29

80

300

42 (1,06 ) PE

22

Style 1586

105

not specified

5,5-20 (0,14-0,50) ETFE

36...6

80

300

30 (0,76) PE

26...16

Style 1589

60...80

30

2-100 (0,05-2,53) PP, PE

min. 36

80

300

AWM

min. 30

Style 1591

150

300

16 (0,40) FEP

26...16

60

30

AWM

min. 30

Style 1592

200

300

16 (0,40) FEP

26...16

60

600

45-60 (1,14-1,52) PVC

18...2

Style 1598

60...80

30

5-100 (0,13-2,53) PE

min. 36

max. 4/0

Style 1605

60

30

4-30 (0,10-0,76) PVC

min. 46

5,5-20 (0,14-0,50) ETFE

Co
n

Style 1479

32...20

Style 1545

Ca
b

Style 1438

5,5-20 (0,14-0,51) FEP

bh

Style 1480

60

600

AWM PVC

Style 1483

105

600

30 (0,76) PVC

28...9

Style 1609

105

125

Style 1495

80

300

15 (0,38) PVC

26...16

Style 1610

105

not specified

10 (0,26) ETFE

32...10

Style 1497

80

300

15 (0,38) PVC

26...16

Style 1618

80

300

15 (0,38) PVC

Style 1498

80

600

30 (0,76) PVC

26...9

Style 1647

80, 90, 105

600

30 (0,76) PVC

30...0

530

36...6

UL styles for single cores


Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

AWG

Style 1683

80

30

35 min. (88) PVC

26...4/0

Style 1692

80, 90, 105

30

4-30 (0,10-0,76) PVC

Style 1707

200

30

Style 1708

200

Style 1709

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

AWG

Style 1901

200

600

14-30 (0,35-0,76) FEP

30...4/0

min.42

Style 1905

105

30

4 (0,10) ETFE

32...20

5 (0,127) PFA

32...20

Style 1908

80

300

15-50 (0,38-1,27) PVC

26...4/0

not specified

5 (0,127) PFA

32...20

Style 1909

200

300

13 (0,33) PFA

32...10

Style 1926

Style 1710

200

600

20-45 (0,50-1,14) PFA

32...4/0

Style 1929

Style 1716

150

150

10-20 (0,25-0,50) FEP

32...6

Style 1930

Style 1723

200

not specified

32...16

Style 1933

Style 1726

250

300

13-45 (0,33-1,14) PFA

Style 1727

250

600

20-45 (0,50-1,14) PFA

Style1729

80

300

9 (0,23) PVC

Style 1766

80

30

3-30 (0,08-0,76) FEP

Style 1792

80

30

2-100(0,05-2,53)PE,PVC

Style 1831

105

150

5 (0,13) ETFE

Style 1837

60

30

Style 1847

105

30

Style 1849
Style 1857
Style1858

gm

30-50 (0,76-1,27) PVC

26...4/0

60-80

300

7 min. (0,17)PE, FRPE

30...16

200

300

13 (0,33) PFA

32...10

200

600

20-45 (0,50-1,14) PFA

30...4/0

250

not specified

6 (0,15) PFA

36...20
30...16

be
l

600

Style 1943

105

30

4 (0,1) FEP

32...4/0

Style 1948

60

60

4-30 (0,10-0,76) PVC

min. 46

32...16

Style 1967

60/80

30

15-48 (0,39-1,22) PVC

20...4/0

min. 42

Style 1968

60/80

not specified

15-48 (0,39-1,22) PVC

20...4/0
32...20

ka

32...4/0

Style 1970

60/80

300

20 (0,5) cell-FEP

24...18

Style 1982

60

30

7 (0,17) PETP

min. 36

5-125 (0,13-3,17) FEP

min. 40

Style 1986

80

30

>2 (0,05) FEP

min. 50

>3 (0,08) FEP

min. 40

Style 1988

105

150

9 (0,23) ETFE

32...10

150-200

300

15 (0,38) FEP

min. 24

Style 1989

105

300

12 (0,31) ETFE

32...10

150-200

600

20 (0,5) FEP

min. 24

Style 1990

105

600

20-45 (0,50-1,14) ETFE

30...4/0

150

150

10 (0,25) PFA

32...16

Style 1999

150

300

>18 (0,45) cell-FEP

min. 36

150

300

13 (0,33) PFA

32...10

Style 10009

150

300

>18 (0,45) cell-FEP

min. 36

150

600

20-45 (0,50-1,14) PFA

32...4/0

Style 10012

20-110 (0,5-2,79) PVC

30...3/0

Co
n

Style 1859

80

min. 40

Ca
b

Style 1848

10 (0,25) FEP

bh

80/90/105

600 or 1000

Style 1860

200

150

10 (0,25) PFA

32...16

Style 10030

250

300

10 (0,25) PFA

30...10

Style 1882

250

150

10 (0,25) PFA

32...16

Style 10031

250

150

6 (0,15) PFA

30...10

Style1886

150

300

10 (0,25) FEP

30...10

Style 10042

80

300

8-22 (0,2-0,56) TPE

Style 1887

150

600

14-30 (0,35-0,76) FEP

30...4/0

Style 10263

80

600 or 1000

12-33 (0,3-0,84) TPE

Style 1900

200

300

10 (0,25) FEP

30...10

Style 10269

80/90/105

1000

32...2
32...1/0

2
30-125 (0,76-3,18) PVC 30...2.10 CM

531

UL styles for cables

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

Braid
alternative

AWG

Style 2089

60

300

30 (0,76) PVC

15 (0,38) PVC

braiding, spiral, metal foil

20...18

Style 2090

60

300

30 (0,76) PVC

15(0,38) PVC

braiding, spiral, metal foil

20...18

Style 2091

60

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral, metal foil

20...18

Style 2092

60

300

15 (0,38) PE, FRPE

15 (0,38) PVC

Style 2093

60

300

15 (0,38) PE, FRPE

15 (0,38) PVC

Style 2094

60

300

15 (0,38) PE,FRPE

Style 2095

80

300

Style 2096

80

Style 2097

gm

bh

30...16

on request

30...16

15-60 (0,38-1,52) PVC

on request

30...16

AWM

15-60 (0,38-1,52) PVC

on request

min. 32

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral, metal foil

80

300

15 (0,38) PVC

Style 2098

90

300

15 (0,38) PVC

Style 2099

90

Style 2100

90

Style 2101

105

Style 2102

105

Style 2103

105

Style 2106

el

on request

30...16

braiding, spiral, metal foil

30...16

15 (0,38) PVC

braiding, spiral

26...16

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral

26...16

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral

26...16

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral

30...16

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral

30...16

300

15 (0,38)PVC

15...60 (0,38...1,52) PVC

on request

30...16

60

600

30 (0,76) PE, FRPE

30 (0,76) PVC

braiding, spiral, metal foil

26...12

Style 2107

60

600

30 (0,76) PE, FRPE

30 (0,76) PVC

braiding, spiral

26...12

Style 2108

60

600

30 (0,76) PE, FRPE

30 (0,76) PVC

braiding, spiral

26...16

Style 2112

80

300

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

25...16

Style 2113

80

300

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

26...16

Style 2114

80

300

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

26...16

Style 2115

80

600

30 (0,76) PVC

30 (0,76) PVC

braiding, spiral, metal foil

26...16

Style 2116

80

600

30 (0,76) PVC

30 (0,76) PVC

braiding, spiral

26...16

Style 2117

80

600

30 (0,76) PVC

30 (0,76) PVC

on request

26...16

Style 2121

90

300/600

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

26...16

Style 2122

80

300/600

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

26...16

nC
ab

ka
b

15 (0,38) PVC

300

Co
532

Wall thickness
sheath
mil (mm)

UL styles for cables

Temperature

Wall thickness
insulation
mil (mm)

Wall thickness
sheath
mil (mm)

Sheath
alternative

AWG

90

300/600

15 (0,38) PVC

30 (0,76) PVC

braiding, spiral

Style 2124

90

600

30 (0,76) PVC

30 (0,76) PVC

braiding, spiral, metal foil

28...9

Style 2125

90

600

30 (0,76) PVC

30 (0,76) PVC

braiding, spiral, metal foil

28...9

Style 2126

90

600

30 (0,76) PVC

30 (0,76) PVC

braiding, spiral, metal foil

28...9

Style 2127

105

600

30 (0,76) PVC

30 (0,76) PVC

on request

28...9

Style 2128

105

600

30 (0,76) PVC

30 (0,76) PVC

on request

28...9

Style 2129

105

600

30 (0,76) PVC

30 (0,76) PVC

on request

28...9

Style 2262

60

600

30 (0,76) PE

15 (0,38) PVC

braiding, spiral

26...16

Style 2263

60

600

30 (0,76) PE

15 (0,38) PVC

braiding, spiral

26...16

Style 2264

60

600

30 (0,76) PE

15 (0,38) PVC

braiding, spiral

26...16

Style 2265

80

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral, metal foil

26...16

Style 2266

80

300

15 (0,38) PVC

15 (0,38) PVC

braiding, spiral

26...16

Style 2267

80

300

15 (0,38) IPVC

15 (0,38) PVC

braiding, spiral

26...16

Style 2268

80

300

30 (0,76) PVC

15 (0,38) PVC

braiding, spiral

26...16

Style 2269

80

300

30 (0,76) PVC

15 (0,38) PVC

braiding, spiral

26...16

Style 2270

80

300

30 (0,76) PVC

15 (0,38) PVC

braiding, spiral

26...16

Style 2271

60

300

as for SVT

as for SVT

26...16

Style 2272

60

300

as for SVT

as for SVT

26...16

Style 2273

60

300

as for SVT

as for SVT

26...16

Style 2274

60

300

as for SVT

as for SVT

26...16

Style 2275

60

300

as for SVT

as for SVT

26...16

Style 2276

60

300

as for SVT

as for SVT

26...16

Style 2277

60

300

as for SVT

as for SVT

26...16

Style 2278

60

300

as for SVT

as for SVT

26...16

Style 2279

60

300

as for SVT

as for SVT

26...16

Style 2280

60

300

as for SVT

as for SVT

26...16

lg

be

ka

nC
a

Co

Style 2123

Voltage

bh

Style

ConCab kabel connects the world

26...16

533

UL styles for cables

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

Braid
alternative

AWG

Style 2281

60

300

as for SVT

as for SVT

Style 2282

60

300

as for SVT

as for SVT

Style 2283

60

300

as for SVT

as for SVT

Style 2284

60

300

as for SVT

as for SVT

26...16

Style 2285

60

300

as for SVT

as for SVT

26...16

Style 2286

60

300

as for SVT

as for SVT

26...16

Style 2287

60

300

as for SVT

as for SVT

26...16

Style 2288

60

300

as for SVT

as for SVT

26...16

Style 2319

90

600

30 (0,76) PVC

Style 2321

80

600

30 (0,76) PVC

Style 2325

90

600

Style 2343

80

Style 2344

el

gm

bh

30 (0,76) PVC

conductive plastic with


copper drain wire

26...16
26...16

26...16
22

braiding, metal foil

not specified

AWM

60 (1,52) PVC

on request

min. 30

not specified

AWM

80 (2,05) PVC

on request

min. 30

Style 2345

80

not specified

AWM

110 (2,80) PVC

on request

min. 30

Style 2346

80

not specified

AWM

140 (3,55) PVC

on request

min. 30

Style 2347

60

600

30 (0,76) PE

15 (0,38) PVC

on request

26...16

Style 2350

80

600

30 (0,76) PE

15 (0,38) PVC

braiding, spiral

26...16

Style 2351

80

600

30 (0,76) PE

30 (0,76) PVC

braiding, spiral

26...16

Style 2352

80

600

30 (0,76) PE

15 (0,38) PVC

braiding, spiral

26...16

Style 2353

80

600

30 (0,76) PE

15 (0,38) PVC

braiding, metal foil

26...16

Style 2354

80

600

30 (0,76) PE, FRPE

30 (0,76) PVC

braiding, metal foil

26...12

Style 2355

80

600

30 (0,76) PE

30 (0,76) PVC

braiding, spiral

26...16

Style 2384

60

30

AWM

35 (0,89) PVC

on request

min. 40

Style 2385

60

30

AWM

60 (1,52) PVC

on request

min. 40

Style 2386

60

30

AWM

80 (2,05) PVC

on request

min. 40

Style 2387

60

30

AWM

110 (2,80) PVC

on request

min. 40

nC
ab

30 (0,76) PVC

80

ka
b

30 (0,76) PVC

26...16

30 (0,76) PVC

Co
534

Wall thickness
sheath
mil (mm)

26...16

UL styles for cables

Style

Temperature

Voltage

Wall thickness
insulation
mil (mm)

Wall thickness
sheath
mil (mm)

Braid
alternative

AWG

Style 2388

60

30

AWM

140 (3,55) PVC

on request

Style 2397

80

300

15 (0,38) PVC

braiding, spiral

Style 2446

80-105

600

30 (0,76) PVC

30 (0,76) PVC 105C

Style 2448

60

30

AWM

30-140 (0,76-3,55) PVC

on request

min. 40

Style 2461

80

300

PVC 80 300V

30-80 (0,76-1,92) PVC

on request

26...16

Style 2462

60

300

SVT/SJT

SVT/SJT

on request

24...10

Style 2463

80

600

AWM

30-80 (0,76-1,92) PVC

on request

min. 40

Style 2464

80

300

AWM

30-140 (0,76-3,55) PVC

on request

AWM

Style 2468

80

300

15 (0,38) PVC

Optional

on request

32...16

Style 2477

60

not specified

AWM

45 (1,14) PVC

on request

36...16

Style 2490

60

not specified

AWM

60-140 (1,44-3,55) PVC

on request

min. 36

Style 2493

60

not specified

AWM

45-80 (1,14-1,92) PVC

on request

30...16

Style 2498

80

Style 2501

105

Style 2502

80

Style 2516
Style 2517

ka

be

lg

bh

min. 40
26...16
18

30 (0,50) PE

30 (0,76) PVC

on request

28...16

600

AWM

60-140 (1,44-3,55) PVC

on request

min. 40

30

AWM

30-140 (0,76-3,55) PVC

on request

min. 40

105

600

AWM

45-80 (1,14-1,92) PVC

on request

min. 40

105

300

AWM

30-80 (0,76-1,92) PVC

on request

min. 32

nC
a

300

80

30

AWM

30 (0,76) PVC

on request

min. 40

Style 2535

80

30

AWM

30 (0,76) PVC

on request

min. 40

Style 2549

90

300

AWM

30-80 (0,76-1,92) PVC

on request

40...16

Style 2550

80

600

AWM

60-140 (1,44-3,55) PVC

on request

min. 40

Style 2551

105

30

AWM

30-140 (0,76-3,55) PVC

min. 40

Style 2560

60

30

AWM

30-140 (0,76-3,55) PVC

on request

min. 40

Style 2570

80

600

AWM

30-80 (0,76-1,92) PVC

on request

min. 40

Style 2571

80

not specified

AWM

30-80 (0,76-1,92) PVC

on request

min. 40

Style 2574

105

30

AWM

30-140 (0,76-3,55) PVC

on request

min. 40

Co

Style 2532

535

UL styles for cables

Temperature

Voltage

Wall thickness
insulation
mil (mm)

Braid
alternative

Style 2576

80

150

AWM

AWM

on request

Style 2582

60

150

12 (0,30) PE, FRPE

AWM

on request

Style 2584

80

125

AWM

AWM

on request

Style 2586

105

600

AWM

AWM

Style 2587

90

600

AWM

AWM

Style 2589

105

30

AWM

AWM

Style 2598

60

300

AWM

Style 2610

80

300

15 (0,38) PVC

Style 2614

105

30

AWM

Style 2626

80

30

Style 2630

90

125

Style 2631

90

not specified

Style 2637

90

Style 2653

90

Style 2654

90

Style 2655

AWG

36...9

30...16
40...9

on request

min. 40

on request

AWM

on request

AWM

lg
AWM

30 (0,76) PVC

be

AWM

30...9

as Style 1007

on request

min. 40

AWM

on request

not specified

AWM

AWM

on request

30...9

AWM

AWM

on request

min. 40

AWM

AWM

on request

min. 40

600

AWM

AWM

on request

36...6

300

AWM

AWM

on request

36...6

80

300

AWM

AWM

on request

36...6

Style 2656

80

600

AWM

AWM

on request

36...6

Style 2660

60

not specified

AWM

AWM

on request

AWM

Style 2661

105

300

AWM

AWM

on request

36...6

Style 2662

105

600

AWM

AWM

on request

33...10

Style 2668

60

30

AWM

AWM

on request

min. 40

Style 2778

60

150

AWM

AWM

braiding, metal foil

30...16

Style 2789

60

30

AWM

AWM

on request

AWM

Style 2833

60

30

AWM

15 (0,38)PVC

on request

Style 2854

80

30

AWM

5 (0,13) PVC

on request

min. 40

Style 2919

80

30

AWM

AWM

on request

min. 40

Ca
b

ka

AWM

30

Co
n
536

Wall thickness
sheath
mil (mm)

bh

Style

UL styles for cables

Temperature
C

Voltage
V

Wall thickness
insulation
mil (mm)

Wall thickness
sheath
mil (mm)

Braid
alternative

AWG

bh

Style

60

30

AWM

AWM

on request

min. 40

Style 2921

60

30

AWM

AWM

on request

min. 40

Style 2930

105

not specified

AWM

AWM

on request

min. 40

Style 2931

105

125

AWM

AWM

on request

min. 40

Style 2934

80

150

AWM

AWM

on request

AWM

Style 2935

80

300

AWM

AWM

on request

AWM

Style 2936

80

150

AWM

AWM

on request

AWM

Style 2937

80

300

AWM

AWM

on request

AWM

Style 2938

90

30

AWM

Style 2941

105

30

> 4 (0,10) PVC

Style 2961

80

Style 3512

200

Style 20063

80

Style 20083

80

Style 20099

60

Style 20233

80

Style 20234

80

Style 20235

el

gm

Style 2920

on request

AWM

9 (0,23) PVC

on request

40...16
AWM

on request

min. 20

ka
b

AWM

on request

300

AWM

30-140 (0,76-3,55) PUR

on request

min. 36

600/1000

AWM

45-140 (1,14-3,55) PUR

on request

min. 36

80

not specified

AWM

45-140 (1,14-3,55) PUR

on request

min. 36

Style 20254

60

30

AWM

AWM

on request

min. 40

Style 20405

60

150

7 (0,18) Hytrel

on request

33...18

Style 20433

60

not specified

AWM

AWM

on request

36...10

Style 20601

80

300

AWM

AWM

on request

AWM

Style 20886

80, 90, 100

1000

AWM

30-140

on request

min. 40

150

AWM

600

AWM

300

20 (0,50) PE

30 (0,76) PVC

on request

28...16

300

AWM

AWM

on request

diff.

30 (0,76) PVC

on request

33...18

Co
n

Ca
b

150

7 (0,18) Hytrel

AWM

30-95 (0,76-2,41) silicone

30 (0,76) PU

ConCab kabel connects the world

537

Flame tests acc. to UL/CSA

bh

Contrary to the valid and practised standards (Germany VDE) and international standards (IEC) in
the European hemisphere for the behaviour of cables in fire, the tests carried out in the USA and
Canada deviate from the ones in Europe.

gm

Here is a brief summary of the most important regulations for cables.

Standard

Test requirements

el

Test identification

UL style 1581, section 1090

UL style 1581, section 1061

VW 1

UL style 1581, section 1080

FT 1

CSA No. 3 / UL style 1581,


section 1060

vertical flame test for


indoor and outdoor cables

FT 2

CSA No. 3 / UL style 1581,


section 1100

horizontal flame test for


indoor and outdoor cables

FT 4

CSA No. 3 / UL style 1581,


section 1164

vertical flame test for


cables on cable trays

horizontal flame test for


indoor cables
vertical flame test for
outdoor cables
vertical flame test for
cables acc. to NEC (National
Electrical Code)

Co

nC
ab

ka
b

538

ConCab kabel connects the world

VOLUME
1 cubic inch
1 cubic foot
1 cubic yard
1 pint
1 quart
1 Brit. gallon
1 US gallon
1 US barell

= 16,39 cm3
= 0,0283 m3
= 0,765 m3
= 0,473 l
= 0,946 l
= 4,55 l
= 3,79 l
= 158,8 l

= 0,5067 mm2
= 645,16 mm2
= 0,0929 m2
= 0,836 m2
= 4047 m2
= 2,59 km2

PRESSURE
1 lbf/in2 (psi)
1 lbf/ft2
1 lbf/yard2

= 4,454 N
= 9967 N
= 0,1382 N

= 68,97 mbar
= 0,479 mbar
= 0,0532 mbar

lg

AREA
1 mcm
1 square inch (sq.in.)
1 square foot (sq.ft.)
1 spuare yard (sq.yd.)
1 acre
1 square mile

FORCE
1 pound-force (lbf)
1 Brit. ton-force
1 poundal (pdl)

ELECTRICAL UNITS
1 ohm/1000 yd
1 ohm/1000 ft
1 megohmmile
1 mF/mile
1 decibel/mile

= 1,0936 W/km
= 3,28 W/km
= 1,61 MW/km
= 0,62 mF/km
= 71,5 mN/km

DENSITY
1 lb/ft3

= 16,02 kg/m3

be

= 0,0254 mm
= 25,4 mm
= 0,305 m
= 0,914 m
= 1,609 m
= 1,852 m
= 20,1 m

ka

LENGTHS
1 mil
1 inch (in;)
1 foot (ft;)
1 yard (yd)
1 statute mile
1 nautical mile
1 chain (ch)

bh

Anglo-American measure units


conversion to SI units

= (1,8 u T + 32) C
T = temperature in C

TEMPERATURE
1 Fahrenheit (F)

nC
a

MASS
1 grain
1 dram
1 ounce (oz) =16 drams
1 pound (lb) =16 oz
1 stone
=14 lbs
1 US ton (short ton)
1 Brit. ton (long ton)

Co

= 64,8 mg
= 1,77 g
= 28,35 g
= 453,59 g
= 6,35 kg
= 907 kg
= 1016 kg

ConCab kabel connects the world

539

Rated-, operating- and test voltage

bh

Rated voltage:

Operating voltage:

ka
be

lg

The rated voltage of a cable is the voltage for which the cable is designed and which determines the
electrical characteristics of the respective cable.
The rated voltage is expressed through the ratio of two alternating current values for U0/U in Volts:
U0 = Effective value between an outside conductor and the earthing (either metal sheath of the
cable or a surrounding substance).
U = Effective value between two outer conductors of a multicore cable or of a system with single
core cables.
In an altenating current system, the rated voltage of the cable must be at least the same as the rated
voltage of the system in which it is applied.
This requirement is valid both for the U0 value as well as for the U value.
The rated voltage of a direct current system may not exceed the 1.5 value of the rated voltage (U) of
the cable.

Test voltage:

The operating voltage of a system may continually exceed its rated voltage by 10 %. A cable may be
operated with a voltage which is 10% over the rated voltage provided it correlates to the rated voltage
of the system.

Co

nC
a

The test alternating voltage (50 Hz) is dependant on the rated voltage of the cable and consequently
on the predetermined value of the core insulation wall thickness.
The predetermined voltage is applied over a specified time to core / core and likewise core / sheath.

540

ConCab kabel connects the world

Electrotechnical formulas
Resistance change with increased temperature
RW = RK ( 1 + a u iJ)
RW = RK + iR

A = strand cross-section in mm

D = E1,34 u n u d

D = strand diameter in mm
n = number of single wires
d = single wire-x in mm

iR = a u RK u iJ

RW= resistance in W
iR = resistance change in W

iJ = RW u RK/R

iJ = temperature change to 20C in C


a = correction value in 1/C

Example

RW = 100 W (1 + 0,0039 u 50)

Conductor resistance
ruL

G = electrical conductive value in S

L
R=
kuA

Ohms law

L = length of conductor in m

1
r = specific resistance in W u mm2 /m

R=

ka

G=

A = conductor cross-section in mm

be

R = electrical resistance in W

= 50C
= 100 W
= 0,0039C
= RK (1 + a u J)

lg

iJ
RK
a
RW

R=

U
I

k = conductibility in m/W u mm2

r= 1
k

U = 300 V; I = 10 A

L =1000 m; K = 58 m/W u mm

R = 300 V = 30 W
10 A

A = 0,75 mm

R = electrical resistance in W
U = electrical voltage in V
I = electrical current in A

Example

Example

RK = resistance at +20C in W

2
A= d ufun
4

bh

Calculation of cross-section of strands and wires

R =kuA

1000
= 23 W
58 u 0,75

nC
a
R=

Material
at 20C

r
W u mm2/m

k
m/W u mm2

Power

a
1/C

copper

0,0173

58,0

0,0040

silver

0,0161

62,0

0,0038

aluminum

0,0287

35,0

0,0038

iron

0,13

7,7

0,0046

constantan

0,50

2,0

0,000005

Co

Power of ten
10 12
10 9
10 6
10 3
10 2
10 1
10 0
10 s1
10 s2
10 s3
10 s6
10 s9
10s12
10s15

Description

Abbreviation

tera
giga
mega
kilo
hecto
deca

T
G
M
K
h
da

deci
centi
milli
micro
nano
pico
femto

d
c
m
m
n
p
f

Value
1000 000 000 000
1000 000 000
1000 000
1000
100
10
1
0,1
0,01
0,001
0,000 001
0,000 000 001
0,000 000 000 001
0,000 000 000 000 001

541

Bending radius of cables for fixed installation


acc. to VDE 0298, part 3
cable- x d resp. thickness of flat cables d

> 25mm
4ud
2ud

> 10mm
4ud
1ud

fixed installation
to form out

> 25mm
4ud
3ud

gm

Type of application

el

Bending radius of cables for flexible application


acc. to VDE 0298, part 3

cable-x d resp. thickness of flat cables d

Type of application

> 12mm

> 20mm

> 20mm

3u
4u
4u
5u
4u
4u
7,5 u

4u
5u
5u
5u
5u
5u
7,5 u

4u
5u
5u
6u
5u
5u
7,5 u

ka
b

> 8mm

3u
3u
3u
5u
3u
4u
7,5 u

d
d
d
d
d
d
d

d
d
d
d
d
d
d

d
d
d
d
d
d
d

d
d
d
d
d
d
d

nC
ab

fixed installation
flexible application
installation in pipes etc.
forced guidance
trolley vehicle operation
drag chains application
guide pulley

Bending radius of installation cables acc. to DIN 815


acc. to VDE 0891, part 5

Cable- x d

shipping

7,5 u cable -x

multiple bending
with tensile load

7,5 u cable -x

Co

Application

bending once
without tensile load

542

bh

Smallest permitted bending radius acc. to VDE regulations


for cables up to 0,6/1kV rated voltage

2,5 u cable -x (exception: J-Y(St)Y...Lg, 5 u cable - x)

ConCab kabel connects the world

bh

Drum and spool sizes

D
d
L1
L2
f

=
=
=
=
=

flange diameter
core diameter
outer flange width
winding width
axis diameter

lg

D d

L2

ka

be

L1

Non-returnable plywood spools


d
mm

L1
mm

400
500
600

150
150
150 - 300

320
420
320 - 420

L2
mm
300
400
300 - 400

f
mm

Load capacity
max. kg

50
50
80

150
200
210

Weight
approx. kg
4
5
6-8

Co

nC
a

01
02
03

D
mm

Spool size

ConCab kabel connects the world

543

D
mm

d
mm

L1
mm

L2
mm

f
mm

KTG wooden drums


150
315
355
400
450
500
630
710
800
1000
1250
1400
1600
1800

470
415
520
520
690
710
890
890
1100
1100
1350
1450
1450
1635

410
315
400
400
560
560
670
670
850
840
1045
1140
1130
1280

56
56
80
80
80
80
80
80
80
100
100
125
125
140

Weight
approx. kg

100
250
250
400
750
900
1700
2000
3000
4000
5000
6000
7500
10000

8
17
25
31
47
71
144
175
280
380
550
710
900
1175

100
250
350
400
500

4
15
16
23
32

el

500
630
710
800
900
1000
1250
1400
1600
1800
2000
2240
2500
2800

ka
b

05/051
06/061
07/071
08/081
09/091
10/101
12/121
14/141
16/161
18/181
20/201
22/221
25/251
28/281

Load capacity
max. kg

gm

Drum size /
Ref. number

bh

KTG cable drums

KTG plastic drums

500
710
800
900
1000

150
355
400
450
500

Ca
b

05/050/7
07/070
08/080
09/090
10/100

456
510
510
680
704

404
400
400
560
560

56
80
80
80
80

Co
n

KTG = Kabeltrommel GmbH & Co, Cologne

544

ConCab kabel connects the world

Capacity of KTG cable drums


in metres
07
071

08
081

1140
820
635
480
410
340
280
235
185
175
145
135
105
100
100
75

1110
845
640
470
385
315
255
235
190
180
140
135
100
95
95
90

2025
1480
1065
890
675
565
470
385
365
295
240
230
220
170
165
160
120
115

2755
2340
1465
1150
980
760
645
540
455
430
360
295
280
230
220
210
165
160
160
150
115

09
091

2730
2200
1770
1405
1205
1030
880
750
630
605
505
485
400
385
315
305
295
285
230
220
215
210
160

10
101

2865
2350
1910
1540
1340
1160
1000
860
735
705
600
575
485
470
390
375
365
300
290
280
225
220
210

12
121

14
141

16
161

18
181

20
201

22
221

25
251

28
281

bh

06
061

2725
2255
1990
1755
1545
1355
1185
1140
990
855
825
710
690
670
565
550
460
450
430
345
330
260
250
190
180
175
130
125

gm

Cable - x
mm
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
32
34
36
38
40
42
44
46
48
50
55
60
65
70
75
80
85
90

05
051

b

Drum size.
Ref. no.

2965
2480
2205
1960
1735
1535
1350
1305
1145
1000
965
840
815
700
680
665
565
535
440
420
340
325
260
250
240
185
180
125

2720
2435
2170
1930
1870
1655
1610
1420
1245
1210
1180
1030
865
830
690
665
550
530
430
415
330
320
235
220
155

2830
2525
2250
2170
1925
1865
1650
1450
1410
1370
1195
1010
960
805
770
640
615
500
485
385
375
275
255
180
170
160
105

2955
2610
2520
2220
2150
1880
1825
1585
1500
1255
1040
995
810
780
750
600
580
560
415
295
275
185
175
165
155
145

2860
2775
2450
2385
2035
1725
1645
1385
1330
1110
1065
875
840
780
625
465
335
315
295
280
190
180

2975
2895
2490
2135
2035
1735
1465
1405
1175
1130
930
900
690
640
480
450
325
305
290
200

2820
2430
2330
1995
1690
1630
1365
1320
1040
805
750
565
530
500
365
350

The above mentioned values are non-binding theoretical values


=drum core- x M 30 u cable -x
=drum core-x M 20 u cable -x
=drum core- x M 10 u cable - x

545

VDE-

Chemical

abbrevation

designation

Density

[g/cm3]

Short-term

Flame

service

operating

operation

temperature

resistance

temperature

(240h)

(20h)

[C]

[C]

[C]

-30...+70

80

100

conditional

-40...+70

80

100

conditional

110

120

conditional

behaviour

Polyvinyl chloride

1,25...1,50

PVC k

Yk

Polyvinyl chloride cold resistant

1,20...1,40

PVC w

Yw

Polyvinyl chloride heat resistant

1,30...1,50

-20...+105

PVC fr

Polyvinyl chloride flame retardant

1,30...1,60

-30...+70

80

100

yes

LDPE

2Y

Polyethylene low density

0,91...0,93

-50...+70

80

100

no

HDPE

2Y

Polyethylene high density

0,94...0,97

-50...+90

110

120

no

PES

02Y

expanded Polyethylene

0,65

-40...+70

no

PA

4Y

Polyamide

1,02...1,15

-60...+105

120

150

no

PP

9Y

Polypropylene

0,95...0,98

-10...+100

110

130

no

PUR

11Y

Polyurethane

1,15...1,20

-50...+80

120

140

no

TPE-E

12Y

Polyester

1,15...1,40

-40...+120

120

150

no

PET

12Y

Polyester (foil)

1,15...1,40

-40...+120

180

200

no

halogen-free Polymer blend

1,40...1,58

-30...+70

80

100

yes

XLPE

2X

cross-linked Polyethylene

0,90...0,93

-35...+90

130

160

no

SBR

Styrol-Butadien-caoutchouc

1,50...1,70

-65...+60

80

120

no

SiR

2G

Silicone-caoutchouc

1,20...1,30

-60...+180

220

260

conditional to yes
no

nC
ab

ka
b

el

PVC

EPR

3G

Ethylene-Propylene-caoutchouc

1,30...1,60

-30...+90

130

160

EVA

4G

Ethylene-Vinylacetate-Copolymer

1,30...1,50

-50...+150

170

200

no

CR (PCP)

5G

Polychloroprene-caoutchouc

1,40...1,70

-40...+100

120

140

yes

CSM (CSP)

6G

chlorsulfonated Polyethylene

1,30...1,60

-30...+80

120

140

yes

CM

9G

chlorofied Polyethylene

1,40...1,70

-30...+90

130

160

yes

PTFE

5Y

Polytetrafluoroethylene

2,00...2,30

-190...+260

300

320

yes

FEP

6Y

Perfluoraethylenpropylene

2,00...2,30

-100...+200

230

240

yes

ETFE

7Y

Ethylenetetrafluoroethylene

1,60...1,80

-100...+150

200

250

yes

ECTFE

Ethylenchlortrifluoroethylene

1,60...1,80

-80...+150

200

230

yes

PVDF

10Y

Polyvinylidenfluoride

1,70...1,90

-40...+135

160

160

yes

PFA

51Y

Perfluoralkoxy

2,00...2,30

-190...+260

280

280

yes

Co
546

Continious

gm

Abbreviation

bh

Chemical and physical characteristics of


(guide value)

ConCab kabel connects the world

Oxygen

Weather

Oil and

c-radiation

Specific

Relative

gases in

index

resistance

fuel

resistance

insulation

permittivity

resistance

resistance

LOI
[mrad]

(20C)
[W . cm]

Tensile

Elongation

strength

at break

[N/mm2]

[%]

(50Hz, 20C)

23...28

moderate (in bk good) moderate

10

1011...1014

3,6...6,0

70...95 A

10...25

150...350

yes

23...28

moderate (in bk good) moderate

10

1013

4,5...6,5

80...95 A

10...25

150...350

yes

23...28

moderate (in bk good) moderate

10

1013

4,5...6,5

70...85 A

10...25

150...350

yes

30...40

moderate (in bk good) moderate

10

1013

80...90 A

10...25

150...350

no

22

moderate (in bk good) poor

100

1017

2,3

40...50 D

8...23

300...600

no

22

moderate (in bk good) moderate

100

1017

2,3

55...66 D

18...35

400...1000

no

18...30

moderate

100

1017

1,5

8...12

350...450

no

22

good

moderate

10

1014

70...80

56...85

70...300

no

22

moderate (in bk good) moderate

10

1017

2,3

55...60 D

21...37

300...600

no

20...25

good

good

500

1012

4...7

80...100 A

30...40

400...700

no

20...25

moderate to good

good

50

1013

4...6

90...95 A

20...40

150...350

no

20...25

100

1013

no

33...40

moderate (in bk good) moderate

100

1012...1014

3,4...5,0

65...95 A

8...13

150...250

no

22

good

moderate

100

1015

4...6

40...45 D

10...25

300...600

no

22

moderate

poor

100

1012

3...5

60...70 A

5...10

250...500

no

25...35

good

moderate

50

1015

3...4

40...80 A

5...20

200...400

no

22

excellent

moderate

200

1013

3,0...3,8

65...85 A

5...20

200...400

no

22

good

moderate

100

1012

5,0...6,5

70...80 A

5...20

200...400

yes

30...35

excellent

good

50

1012

6,0...8,5

55...70 A

15...25

300...600

ka

be

yes

[%O2]

hardness

lg

case of fire

Shore-

Corrosive

bh

insulation and sheath materials

nC
a

good

150...200

50...150

yes

30...35

excellent

good

50

1012

6...9

60...70 A

15...25

300...600

yes

28...35

excellent

good

50

1012

6...8

60...80

10...20

300...600

yes

>95

excellent

excellent

0,1

1017

2,1

55...65 D

80

yes

>95

excellent

excellent

0,1

1016

2,1

55...60 D

15...25

250

50

30...35

excellent

excellent

100

1016

2,3...2,6

70...75 D

40...50

150

60...65

excellent

excellent

100

1015

2,5

75...80 D

40...50

150

yes

40...45

excellent

excellent

10

1014

7,0...10,6

75...80 D

50...80

150

yes

>95

excellent

excellent

1017

2,1

55...60 D

25...30

250

Co

yes

yes

0,1

ConCab kabel connects the world

547

Mounting instructions for high flexible cables

ka
b

el

3. CC-Schleppflex/CC-Servoflex on drums
should be unreeled from the drum in order
to avoid kinks. Therefore, it should be
avoided to take the cable in loops over the
flange of the drum. We recommend to
install the cable torsion free on the cable
chain immediately after cutting the cable
in the required length. If it is necessary to
stock a precut length, the cable should be
stocked stretched. An axial twisting of the
cable has to be avoided at any time.

gm

2. It must be ensured that the minimum bending radius is never less than the permitted bending radius.

bh

1. CC-Schleppflex/CC-Servoflex on coils
should be only recut from the out-to the
inside layer and should be installed in the
cable chain without any torsion on the
cable. This means that the cable should
not be twisted in any way (please see
picture).

Co

nC
ab

4. Chain cables have to be installed loosely


in the cable chain, that is, without any
restraint in the cable chain. Do not attach
several cables together in the cable chain.
Various cables in the cable chain should
be separated by separators. The size of the
cable chain should be such that they allow
sufficient space for cable movements
(please see picture).

548

ConCab kabel connects the world

m
lg

be

6. The connection, i.e. the fixation point of


the cable on each side of the cable chain
should be at least 30 x cable diameter
from the end of the bending point of the
chain. Stress on the fixation point has to
be avoided. The strain relief should be
applied over a large area of the outer
sheath. Crushing the conductors of the
cable will shorten the service life of the
cable. In any case, the cable can never be
moved all the way to the connection
point.

bh

5. For all Schleppflex cable, it is recommended, to check the position of the cable
after a short operation time period.

ka

7. In case of a shielded cable, we recommend to fasten the shield with the use of
a cable tie, in order to avoid dislocation or
migration of the shield.

8. If one of the cables in the cable chain


is defective, all cables should be replaced,
as otherwise quality deviations due to
mechanical stress (straining) could occur.

Co

nC
a

9. If it is technically possible, it is recommended to replace a high core cable with


several few core cables. To increase the
service life, it is best to coordinate the
choice of a cable chain together with the
cable.

ConCab kabel connects the world

549

Installation guide for crane cables


CC-crane cable NSHTU-K, NSHTUK-Z, CC crane cable PUR

During unreeling, the cable may only be drawn


off from a stand supported revolving drum
tangentially from above. The cable must be
drawn off tight and not be twisted or drawn
over edges.

3.

Before installing the cable it must be stretched


out. If that is not possible the distance between the
the supply drum and the appliance drum must be
kept at a maximum. It may not be wound onto the
appliance drum in an S-form or other
deformations.

Cables with an outer diameter up to 21,5 mm


must have an inner bending radius not less then
10 times the diameter of the cable. Greater outer
diameters may not fall short of 12,5 times the
diameter of the cable. Cables with an outer diameter
up to 21,5 mm may have five times of the inner
bending radius when used for power supply chains.
Greater outer diameters may not be less 6,25 times the
diameter of the cable.
With NSHTUK-Z the inner bending diameter
must be generally at least 15 times that of the
cable diameter. With the CC-crane cable PUR the
inner bending radius must not be less than 20 times
the cable diameter.

bh

2.

6.

gm

If possible the drum should be transported right


to the place where it will be used. If the drum
cannot be brought to the installation point, then
the cable should be unreeled over rollers
using a traction rope with cable stocking.

7.

S-twirls should be avoided in the cable.


If this is practically not possible, then the distance
between the centres of both cable winding roller
axes for cables with a diameter of up to 21,5 mm,
should be at least 20 times that. However if the cable
has an even greater diameter, then the distance
between centres axes must be at least 25 times the
cable diameter.

incorrect

incorrect

8.

The permitted speed may be up to v = 2 m/sec with


an acceleration of up to a = 0,4 m/sec2. The static
continual tensile stress may not exceed 15 N/mm2 of
the entire copper cross-section. The dynamic peak
tensile strain may not exceed 25 N/mm2 .

nC
ab

correct

ka
b

el

1.

The cable must be wound onto the appliance cable


drum without any twist and firmly connected to the
feed-in of the appliance without any kinking. If there
is an overrun when operating the feeder point, then a
compensation disc with the corresponding diameter and
with 1-2 cable windings be used. If the feed-in point is
underground in surface, then a guidance funnel
should be inserted over the compensating disc.

5.

Large band clamp fittings (length x 4 x D) should be


used to fix the cable to the end of the the guidance duct
to avoid crushing of the cable. The unreeled
stretch of length of the cable must be at least
40 x D before the fastening point. When the cable is
unreeled from the appliance drum, make sure that at
least a length of 2 windings always remain on the drum.

Co

4.

550

ConCab kabel connects the world

Installation instructions for lift control cables


CC-Lift-H, CC-Lift-S, CC-Lift-2S

1.

These cables can be installed with a temperature range from


-15C to +70C. If the conductor temperature rises due to the
current load, the regulations of VDE 0100 must be followed.

2.

The inside bending diameter may not be less then 40 times


of the cable diameter.

The max. suspension length is dependent of the respective


supporting core in the cable (see catalogue
specifications).

m
fastening
point

movement direction

be

CC-Lift

diag.1

Suspending the cables

ka

winding directioon

fastening
point

cabin

Fastening the cables


1.

Only large band clamp fittings may be used to fasten the cable
whereby the supporting transmission line must be fixed
seperately.

2.

To ensure a twist-free feed-in, the cable must be allowed


to suspend freely in the shaft for a short time period.

2.

3.

The free space between the lift cabin and the shaft floor
must be sufficiently large enough to accomodate the
height of the cable loop (see diag. 3).

The fastening point on the side of the shaft wall must be at


least 2 m above the middle of the travelling distance (see
diag.3)

3.

If there is an unsteady movement, i.e., the cable


swings away from the operating drop line, then the cable
should be freely suspended again or be twisted slightly at one
of the fastening point to ensure a non kinking run.

4.

If the lift installation requires the cabling of several control


cables, then it is to be recommended from an operational point
of view to hang the individual cables in such a manner that
there is a height difference between the various loops of
approx. 10 to 20 cm (staggered suspension).

The cables must be tangentially unreeled off the drum


when feeding them into the shaft. An axial or overhead
unreeling can cause the bundled strands to twist and
even break the cores (see diag.3).

Co

nC
a

1.

2m

The delivered drum should be, if possible, driven directly to the


place where the cable will be used. The drum may only be rolled
on the ground in the direction indicated (s. diag.1).

lg

4.

supporting rope

bh

General information

correct:
tangential

incorrect:
axial
diag. 2

ConCab kabel connects the world

551

gm

bh

Calculation of metal surcharge price

On account of the unstable prices for metal (stock exchange notation, e.g. DEL*- notation of copper) the selling price for
cables is generally at the basic price, i.e., a selling price is drawn up on a fixed metal price. Usually the price is quoted for
cables made with copper on the following basis:
150. - EUR/100 kg (flexible cables)
100. - EUR/100 kg (telephone and communication cables)
0. - EUR/100 kg (power cable) = hollow price

el

Basic copper:

ka
b

The additional copper price is calculated as in the following equation:


(DEL + 1% purchase price) - copper price in EUR/100 kg
Copper surcharge in EUR/km = copper weight in kg/km u
100
*DEL (German electrolytic copper for conductive purposes) = national stock exchange notation for 99,5% pure copper in EUR/100 kg (current
rate is published in the economic part of daily newspapers or directly on the stock exchange).

Ca
b

Example:
CC-control cable PVC-JZ 25 G 1,5mm2 (part no. 110 0015 025)

copper weight = 360 kg/km


DEL = 173 EUR/100kg of day, month, year
copper basis = 150 EUR/100 kg

That gives a copper surcharge in EUR /km = 360u

(173 + 1,73) - 150 = 89,03 EUR/km


100

Co
n

In the same way calculations for aluminium, silver, gold and lead are based on the current rate.

552

ConCab kabel connects the world

Index
Part
regular
no.

Cable type

01
0102
0103
0104
0105
0106
02
08
09
1007
1007
101
1015
1015
102
1028
1028
107
110
111
1110
1111
112
1130
115
116
117
118
120
121
127
128
1283
1283
1284
1284
130
131
132
132
136
140
141
141
142
142
142
142
143
144
147
148
152
1587

POF cable
fibre optic universal cable
fibre optic outdoor cable
fibre optic breakout cable
fibre optic minibreakout cable
fibre optic indoor cable
POF cable, duplex
PVC control cable orange-JB
PVC control cable yellow-JB
PVC single core UL-Style 1007/1569
PVC multinorm single core UL Style 1007/1569
PVC control cable-JZ (blue cores)
PVC single core UL-Style 1015
PVC multinorm single core UL Style 1015
PVC control cable-JZ (red cores)
PVC single core UL-Style 1028
PVC multinorm single core UL Style 1028
PVC control cable blue-JZ
PVC control cable-JZ
PVC control cable-JB
control cable H-JZ halogen-free
control cable H-JB halogen-free
PVC control cable-OZ
control cable H-CH-JZ halogen-free, shielded
H05VV5-F
H05VVC4V5-K
PVC control cable blue-OZ
H05VVH6-F, H07VVH6-F
PVC control cable-JZ-SY
PVC control cable-JB-SY
PVC control cable blue-OZ-CY
LiYCY-(TP) blue
PVC single core UL-Style 1283
PVC multinorm single core UL-Style 1283
PVC single core UL-Style 1284
PVC multinorm single core UL-Style 1284
PVC control cable-JZ-CY
PVC control cable-JB-CY
Feedback-Sensor cable PUR-C
Feedback-Sensor cable PUR-C UL/CSA DESINA
PVC control cable black-JZ-CY 0,6/1kV
H05BQ-F, H07BQ-F
PUR control cable-JZ
PUR control cable-JZ UL/CSA 600V
PUR control cable-JZ-C11Y
PUR control cable-JZ-C11Y UL/CSA 600V
Feedback-Sensor cable PUR-C
Feedback-Sensor cable PUR-C UL/CSA DESINA
PUR control cable-JZ flame retardant
PUR control cable-OZ-C11Y
PUR control cable yellow-JB
PUR control cable-OZ
PUR control cable-JZ-C11Y flame retardant
Servo 2Y-(St)-CY 0,6/1kV halogen-free

Page
340
344
346
342
343
341
340
190
191
496
498
186
500
502
186
500
502
188
180
183
247
252
180
252
210
212
188
396
204
206
200
280
500
502
500
502
196
198
98
100
202
245
228
230
232
234
98
100
236
232
244
228
238
110

Part
regular
no.

Cable type

Page

162
167
168
170
170
171
180
181
181
182
182
183
183
186
187
190
192
210
216
217
220
220
222
223
224
225
226
227
228
230
232
240
241
242
243
244
245
246
247
248
251
251
252
252
253
253
260
261
270
271
281
282
283

PVC control cable-CEI-162 FR


PVC Multinorm HAR, UL/CSA 600V
PVC Multinorm-CY HAR, UL/CSA 600V
LAN-cable for ETHERNET-Networks
Control-Tray-TM
Control-Tray-TM-CY
Lift-H
Feedback-Sensor cable PUR-C
Feedback-Sensor cable PUR-C UL/CSA DESINA
Feedback-Sensor cable PUR-C
Feedback-Sensor cable PUR-C UL/CSA DESINA
Feedback-Sensor cable PUR-C
Feedback-Sensor cable PUR-C UL/CSA DESINA
Lift-S
Lift-2S
PUR crane cable 0,6/1kV
PVC-CY flat control cable, shielded
LiYY
Li2YH
LiHH
LiYCY
LiYCY UL/CSA 300V
LiY-LiYDY-Y
LiYCY-OZ
LiYCY-CY
LiYCY-JB
LiYCY-JZ
LiHCH
LiHCH-(TP)
LiYY-(TP)
Feedback-Sensor cable PUR-C UL/CSA low capacitance
LiYCY-(TP)
LiYCY-CY-(TP)
Feedback-Sensor cable PUR-C UL/CSA low capacitance
LiFYDY
LiFYCY-(TP)
Li2YCY-(TP)
Li2YCYv-(TP) black
Li2YCH
Li2YCH-(TP)
Feedback-Sensor cable PVC-C
Feedback-Sensor cable PVC-C UL/CSA DESINA
Feedback-Sensor cable PVC-C
Feedback-Sensor cable PVC-C UL/CSA DESINA
Feedback-Sensor cable PVC-C
Feedback-Sensor cable PVC-C UL/CSA DESINA
JE-LiYCY ... Bd
JE-LiYCY ... Bd blue
PiMF Li2YCY
PVC LVCC UL 30V/300V
Feedback-Sensor cable PUR-C UL/CSA low capacitance
Feedback-Sensor cable PUR-C UL/CSA low capacitance
Feedback-Sensor cable PUR-C UL/CSA low capacitance

224
214
217
334
220
222
393
98
100
98
100
98
100
394
395
406
398
256
296
288
262
268
284
274
281
276
270
291
294
260
102
278
282
102
285
286
306
307
299
302
94
96
94
96
94
96
315
316
310
308
102
102
102

553

Index
Part
regular
no.

Cable type

300
305
305
325
326
327
328
329
33G
330
331
332
333
335
336
340
341
345
348
350
353
354
355
356
357
358
360
363
365
370
371
372
380
384
385
386
387
390
410
420
421
421
425
430
431
432
435
436
437
440
450
471
471
471

monitor and video coaxial cable


coaxial cable
LAN-cable for ETHERNET-Networks
SiF
FZL-Si
FZL-Si/GL/Si
Nonflam single core 1400C
Nonflam single core 450C
LAN-Cable for Token-Ring-Networks
SiF/GL
H05SJ-K
H05S-U
H05S-K
SiD
SiD/GL
SiFF
SiZ
FEP/PTFE single core MIL-W 16878 AWG
FEP/PTFE single core MIL-W 16878 metric
NSGAFU 1,8/3kV
SiF UL/CSA
earthing rope X00V3-D
H01N2-D, H01N2-E
earthing rope ESY
earthing rope ESUY
NSHXAF 1,8/3kV
H07V-U
LiFY 1kV
LiYv
H05V-K, X05V-K
EVA multi core cable 150C
EVA multi core cable 150C, shielded
H07V-K, X07V-K
H05V2-K, H07V2-K
Therm 150C
Silikon single core 1,1kV - 13,8kV
Solar 120C
PUR single core 1kV
J-YY ... Bd
J-Y/St)Y ... Lg
J-2Y(St)Y ... Bd
J-H(St)H ... Bd
BUS-EIB PVC
JE-Y(St)Y ... Bd
PiMF RE-2Y(St)Y-(TP)
RD-Y(St)Y-(TP)
RD-Y(St)Yv-(TP)
RE-2Y(St)Y-(TP) blue
RE-2Y(St)Y-(TP) black
A-2Y(L)2Y ... Bd
A-2YF(L)2Y ... Bd
LAN-cable F/UTP
LAN-cable SF/UTP
LAN-cable S/FTP PiMF

554

Page
336
336
334
426
434
434
459
458
335
426
432
432
432
426
426
426
434
452
450
380
428
508
384
508
508
382
492
495
492
492
420
422
492
494
418
430
424
504
350
352
317
362
170
314
322
324
326
318
320
366
368
328
330
332

Part
regular
no.

Cable type

471
471
471
480
480
481
482
483
484
485
500
501
502
503
504
510
512
513
566
567
568
569
569
570
570
570
570
571
572
572
573
573
573
573
573
574
574
575
575
576
576
577
579
580
580
581
581
582
582
583
583
584
585
586

Ether-BUS
174
Schleppflex-Ether-BUS
175
LAN-cable for Token-Ring-Networks
335
EIB-BUS halogen-free
170
fire alarm cable J-Y(St)Y ... Lg red
355
fire alarm cable J-YY ... Bd red
354
fire alarm cable J-H(St)H ... Bd red
364
fire alarm cable JE-H(St)H RH ... Bd E90/FE180 red
360
fire alarm cable JE-H(St)H ... Bd E30/FE180 red
356
fire alarm cable JE-H(St)H ... Bd E90/FE180 red
358
control cable robust-JZ 300/500V
20
control cable robust-JB/JZ 450/750V
22
control cable robust-C-JZ shielded
24
Schleppflex robust-JZ
26
Schleppflex robust-C-JZ
28
Schleppflex PVC/PUR-C-(TP) UL/CSA 300V
88
Schleppflex TPE/PUR-C-(TP)
90
Schleppflex PP/PUR-C-(TP) UL/CSA 300V low capacitance 92
Sensor-Actuator cable PVC
154
Schleppflex Sensor-Actuator cable PUR UL/CSA
155
TPE/PUR-C control cable black UL/CSA 600V
86
Schleppflex TPE/PUR-C
74, 78
Schleppflex TPE/PUR-C UL/CSA 600 V
80
Schleppflex PVC/PVC
30, 34
Schleppflex PVC/PVC UL/CSA 300V
32
Schleppflex PVC/PVC black UL/CSA 600V
40
Schleppflex PVC/PVC single core black ULCSA 600V 38
TPE/PUR control cable black UL/CSA 600V
84
Schleppflex TPE/PUR
64, 68
Schleppflex TPE/PUR UL/CSA 600 V
70
Schleppflex PVC/PVC-C
42, 46
Schleppflex PVC/PVC-C UL/CSA 300V
44
Schleppflex PVC/PVC-C black UL/CSA 600V
50
Schleppflex PVC/PVC-C single core UL/CSA 600V
48
Servo PVC 0,6/1kV
128
Schleppflex PP/PUR UL/CSA 300V low capacitance
66
Schleppflex PP/PUR UL/CSA 600V low capacitance
72
Schleppflex PVC/PUR
52, 54
Schleppflex PVC/PUR UL/CSA 600V
56
Schleppflex PVC/PUR-C
58, 60
Schleppflex PVC/PUR-C UL/CSA 600V
62
Servo PVC-C 0,6/1kV UL/CSA
130
Servoflex PUR 0,6/1kV
140
Servoflex PUR 0,6/1kV
112
Servoflex PUR UL/CSA DESINA 0,6/1kV black
114
Servoflex PUR-C 0,6/1kV
116
Servoflex PUR-C UL/CSA DESINA 0,6/1kV orange
118
Servoflex PUR-C DESINA 0,6/1kV
142
Servoflex PUR-C UL/CSA DESINA 0,6/1kV
144
Servoflex PUR-C UL/CSA single core low capacitance 120
Servoflex PUR-C UL/CSA low capacitance
122
Servoflex PUR-C UL/CSA low capacitance
146
Servo PVC-C UL/CSA DESINA 0,6/1kV
108
Servo PVC UL/CSA DESINA 0,6/1kV
106

ConCab kabel connects the world

Page

Index
Part
regular
no.

Cable type

Page

586
587
588
588
592
592
592
600
610
610
611
614
614
616
629
628
630
639
640
710
720
722
724
726
730
731
732
733
735
736
740
742
750
800
802
804
807
808
810
820
850
851
856
857
858
860
861
862
863
871
880
881

control cable black 0,6/1kV


Servo 2Y-(St)-CY 0,6/1kV
Servoflex single core UL/CSA low capacitance 0,6/1kV
Servoflex motor-cable UL/CSA low capacitance 0,6/1kV
Servoflex-Linear PUR-C UL/CSA DESINA
Schleppflex PP/PUR-C UL/CSA 300V low capacitance
Schleppflex PP/PUR-C UL/CSA 600V low capacitance
PVC control cable 105C
SiHF
SiHF UL/CSA 600V
H05SS-F
Si-C-Si
Si-C-Si UL/CSA
Silicone cable-C-Si UL/CSA
Nonflam multi core cable 450C
Nonflam multi core cable 1400C
SiHF-GLS
FEP multi core cable
PTFE multi core cable
H05RR-F
H05RN-F
Hydro-N submersible rubber cable
Hydro-T submersible rubber cable
Hydro-T-flat submersible rubber cable
H07RN-F
Neoprene flat cable
NSHTU 0,6/1kV
Neorund rubber control cable
Neoprene flat cable, shielded
LAN-cable for Token-Ring-Networks
A07RN-F
NSHTUK-Z 0,6/1kV
NSSHU 0,6/1kV
compensating cable
NYY-J 0,6/1kV
NYY-O 0,6/1kV
NYM-O
NYM-J
NYCWY 0,6/1kV
NYCY 0,6/1kV
NHXMH-J
NHXMH-O
N2XH-J 0,6/1kV
N2XH-O 0,6/1kV
N2XCH 0,6/1kV
NHXH-J/O E30/FE180 0,6/1kV
NHXCH E30/FE180 0,6/1kV
NHXH-J/O E90/FE180 0,6/1kV
NHXCH E90/FE180 0,6/1kV
H05Z-K, H07Z-K
(N)HMH-J
(N)HMH-O

192
110
124
126
148
76
82
416
436
438
440
442
444
446
460
462
448
454
456
377
377
386
388
390
377
400
404
410
402
335
377
408
412
371
464
466
472
472
470
468
476
476
478
478
480
482
484
486
488
506
474
474

Part
regular
no.

Cable type

90
91
910
911
913
92
93
93
93
930
931
935
94
94
94
95
997

Robotflex PUR UL/CSA


Robotflex PUR-C UL/CSA
BUS PVC-C for DeviceNet
BUS-Schleppflex PUR-C for DeviceNet
BUS-FF-PVC-C
Robotflex PUR-C UL/CSA
Robotflex PUR-C UL/CSA
BUS PVC-C UL/CSA DESINA
BUS CAN-PVC-C UL/CSA DESINA
BUS AS-Interface Fieldbus cable
BUS-Schleppflex Hybrid-PUR DESINA
LONBUS shielded
BUS-Schleppflex PUR-C UL/CSA DESINA
BUS-Schleppflex CAN-PUR-C UL DESINA
BUS-SAFETY PUR-C UL/CSA
BUS PA-C PVC for PROFIBUS PA
Spiral cable PUR

ConCab kabel connects the world

Page
150
152
172
173
164
152
152
158
166
168
171
163
160
167
162
176
240

555

European Directives WEEE, RoHS, ElektroG & Reach


WEEE
Waste Electrical and Electronic Equipment
Directive is the European Union (EU) directive
2002/96/EC and became European Law in
February 2003.

that fall under the categories of ElektroG, we mark


all our products in our catalogue which either
comply with the limited values governed by the
ElektroG (WEEE/RoHS) 5 and/or do not violate
provisions of the ElektroG (WEEE/RoHS).

The WEEE directive aims to reduce the amount of


waste of electrical and electronic equipment in
such a way, as to prevent their entry into the waste
stream.

REACH
As of 1st of June 2007, a new regulation, EC No.
1907/2006, of the European Parliament came into
force, creating a harmonized System for the
Registrations, Evaluation, Authorization and
Restriction of Chemicals.

In order to attain a consistent level of health and


environmental protection throughout the member
states of the EU, all members are obliged to set out
regulations for the re-use or recycling of these
devices.
RoHS
Restriction of use of certain Hazardous Substances
in electric and electronic equipment
The directive 2002/95/EC of the European
Parliament and the Council restricts the use of
following hazardous substances in electric and
electronic equipment from 1st of July 2006:
Lead, Mercury, Cadmium, Chromium VI
Polybrominated biphenyl (PBB)
Polybrominated diphenylether (PBDE)
Decabromodiphenylether (Deca-BDE)
ConCab kabel already fulfilled the requirement of
these limit values before the given date of 1st of
July 2006 and ongoing sample tests of our
products verify the further compliance. Due to the
wide range of our supplying products, however, it
is not feasible to provide unexceptional evidence
and as such, this is not meant as an unconditioned
confirmation which implies liability or warranty.
ElektroG
Electrical and Electronic Equipment Act
Germany has set national rules in March 2005,
under the ElektroG Act, integrating both European
directives 2002/96/EC (Weee) and 2002/95/EC
(RoHS).
As such, this Act aims to avoid waste of electrical
and electronic equipment and implies rules for the
re-use and/or recycle of these electronic devices.
Products supplied by ConCab kabel, are not governed by the ElektroG as they do not have an
independent function. However, in order to assist
our customers that may use our products in devices

556

Its aim is to achieve a high level of protection for


the environment, health and safety. REACH is
regulating resp. restricting certain chemical
substances or mixtures of chemicals which are
produced, imported or traded in the European
Union.
ConCab kabel is neither a manufacturer nor an
importer of these substances or mixtures.
Our products do not need to be registered under
REACH. ConCab kabel is seen as a Down Stream
User as we are a producer of cables - not
chemicals. Nevertheless, if possible, we always
intend to use substances which are safe to use and
minimize the environmental impact. We closely
observe the list of Substances of Very High
Concern (SVHC) and continuously evaluate and
develop our products for a friendlier environment.
Cable Recycling
our responsibility to the environment:
The environment is our highest fundamental
source. As such, we take our environmental
responsibilities very serious.
We offer a wide range of halogen-free products
which reduce the risk to humans, environment and
plants in the event of fire and give benefits for
recycling. Our R&D department continuously
works on the improvement of consisting products
and on the development of new, environmentally
friendly, products. Furthermore, we try to reduce
the amount of packaging and aim to use
environmentally friendly packaging which is free
of asbestos and free of CFC.
Up to the end, where we offer all or customers to
return old cables to us. We ensure that all old
cables are disposed in an environmentally
safe-way.

Inquiry
Address

Order
Delivery Address

Customer No.:

Company name:

Company name:

Street:

Street:

Zip:

Zip:

City:

City:

Country:

Country:

Contact person:

Contact person:

Phone

Fax:

Email:

Date:

Ref.-No:

Delivery date:

CC-part no.

Your part no.

Description / No. of cores & cross-section

Length / Packing

Add. information:

Please use our faxhotline: +49 (0)7903 - 91 55 89 oder email: order@concab.de


your order is subject to our conditions of sales
ConCab kabel gmbh | Am Moosbach 7-9 | 74535 Mainhardt
Phone: +49 (0)7903 - 91 55 0 | Fax: +49 (0)7903 - 91 55 88
Internet: http://www.concab.de | Email: info@concab.de

557

Spiral cable request sheet


To:
ConCab kabel gmbh

From:
Company:
Contact person:
Address:

Am Moosbach 7-9
74535 Mainhardt
Tel: +49 (0)7903 / 91 55 0
Fax: +49 (0)7903 / 91 55 89
Email: technik@concab.de

Phone:
Fax:
Email:

L
L0
D
D0
L1
L2
L3
L4
L5
L6

Form of the ends:

tangential

Effective length:
Spiral length closed:
Cable diameter:
Spiral diameter:
Length end 1:
Length end 2:
Dismantle end 1:
Dismantle end 2:
Adaption end 1:
Adaption end 2:

axial

(as shown on picture above)

Outer sheath material:

PVC

Sheath color:
Insulation material (core):

PUR

Rubber

No. of cores:

PA

others
Cross-section:
Shield:

yes

no

Application conditions:

Temperature / surrounding:
Remarks:

No. of pieces:

Please use our fax hotline: +49 (0)7903-9155-89 or Email: technik@concab.de


558

Special cable request sheet


From:

To:
ConCab kabel gmbh

Company:
Contact person:
Address:

Am Moosbach 7-9
74535 Mainhardt
Tel: +49 (0)7903 / 91 55 0
Fax: +49 (0)7903 / 91 55 89
Email: technik@concab.de

Phone:
Fax:
Email:

Cable construction:

Electrical characteristics:

Conductor stranding
Conductor:
silvered

CU

acc. to DINVDE 0295

Rated voltage:

class 5

class 6

Conductor resistance:

Ohm/km

CU bare

tinned

Insulation resistance:

Ohm/km

PVC

nF/km

Capacitive coupling:

polyester

silicone

teflon

Capacity at:

element

Core insulation

Volt

rubber

at

Hz:

pF/100m

Hz:

mH/100m

Inductivity:
PE polyethylene

at

Core identification

black with consec. white numbering

colored acc. to VDE 0293

colored acc. to DIN47100

Mechanical/ thermal characteristics:

with

gnye protective conductor

Application condition:

without

other:

Shield

yes

no

copper

steel wire braid

aluminium foil

braided shield

spiral shield

cores seperately

paired

cores, shielded
PVC

with

PUR

Application:
air

without touch protection


teflon

inside
water

fixed installation

earth
flexible application

drag chain application

other:

outside

robotic application

applied in:

with

without overall shield

with

without drain wire

Is the cable in contact with any chemicals, liquids,


acids and oils?

Strain relief core

with

without

Outer sheath:

PVC

polyester

teflon

silicone

no

yes, in

Temperature range:

Bending radius:
Other characteristics:

rubber

PE polyethylene:

C up to +

mm

other:

Outer sheath color:

grey RAL 7001

grey RAL 7032

black RAL 9005

other:

Outer diameter:

mm

Quantity:

meters

Please use our fax hotline: +49 (0)7903-9155-89 or Email: technik@concab.de


559

Notes

560

ConCab kabel gmbh General Conditions of Sale


I. General terms
1. The following conditions shall apply to all our quotations and contracts, to current and
future transactions. They shall be recognized by the buyer at latest with the receipt of the
goods or services and need not be agreed upon expressively.
2. Any diverging agreements, such as amendments, collateral agreements and supplements
as well as diverging general terms and conditions or purchasing conditions of our
customers are herewith expressively and definitely opposed.
3. Deviations from our terms and conditions shall not become effective unless we have
confirmed them in writing and are only effective for the particular project.
II. Contract and Prices
1. Our offers and price lists are not binding; they are without obligation and subject to our
written order confirmation.
2. Our sales agents and distributors are not authorized to give guarantees or make arrangements which differ from our general contract terms and conditions. Any deviations from
our general conditions of sales have to be confirmed by us in writing on the order
confirmation to be valid.
3. Our prices are on principle to be understood in EUR, plus VAT as stipulated by law at the
time of shipment, as well as freight and packing costs for the individual order concerned.
They only include the mentioned services, any special services shall be
invoiced additionally. Shipments outside Germany are not subject to VAT.
4. For a net order value of up to EUR 160,-- an additonal min. quantity surcharge of
EUR 15,-- is being invoiced.
5. Prices stipulated by us correspond to the present cost situation. They include a copper
basis of EUR 150,-- per 100kg copper, excluded are the underground cables with hollow
prices (copper basis 0) as well as telephone cables with a copper basis of EUR 100,-per 100 kg copper. Decisive for the determination of the sales price is the value of the
corresponding DEL notice at the date of our order confirmation. If the notation of the day
differs from the copper basis, the list price for 1000 m cable shall increase by the amount
resulting from the multiplication of the copper weight with the difference from the metal
notation. The metal calculation for cables with other conductor materials/metals
(e.g. nickel, silver, aluminum) shall be analog to the copper price determination in our
order confirmations. They are valid on conditions of an unhindered execution of the order
and unchanged cost of wages and materials. If the costs of material, wage or transport
cost, taxes or duties increase unforeseen, we shall be entitled to recalculate the prices at
the date of shipment if the shipment is made later than 4 months after conclusion of the
contract. If the customer makes modifications after our order confirmation, we shall be
entitled to adjust prices in accordance to cost surplus caused by the modification.
III. Costs for shipping and packing
1.Items sold on meter basis up to 40kg resp. up to 250m will be delivered as a ring. Items
longer resp. heavier will be delivered on drums. If no packing lengths are specified on the
order, we reserve the right to determine the lengths according to our standard lengths.
A cut length surcharge per special length will be charged for special cutting length
requests. Accessories will solely be delivered in packaging units as specified in our catalogue or our order confirmation.
2. Goods with a value of EUR 400,-- or more per shipment will be shipped within Germany
to the station of destination carriage paid. However, no freight charges will be
reimbursed nor will any collecting compensation be paid in case of collection by the
customer. An express shipment of any other special shipping mode required by the
customer shall in any case be at his expense.
3. The packing is always invoiced additionally. For large stable containers of wood, metal
and other materials we reimburse 3/4 of the packing cost if they are returned undamaged
and carriage paid.
4. If cables are supplied on drums from Kabeltrommel GmbH, Cologne (KTG), the drum
rent as well as the deposit value will be invoiced according to the KTG contract
conditions. As soon as the KTG drums are free, KTG has to be informed accordingly.
The corresponding KTG conditions shall be accepted by the customer to whom they will
be sent upon request. If the cable is supplied on ConCab drums resp. non-returnable drum,
no drum rent will normally be charged. It is only the supplier`s choice to decide whether
returnable or non-returnable drums are used for shipment. In case of returnable pakkings/drums, the customer shall be responsible for the correct handling and return, which
shall be at his own risk and expense.
IV. Execution and quantity
1. Material, colour, weight, dimensions, technical design or similar characteristics may be
subject to alterations provided that the subject delivered remains as a whole acceptable
to the customer.
2. All quantities, dimensions and technical information shall in other respects be subject
to the commericial tolerances, quantity increases or reductions up to 10% are admissible.
V. Delivery times, self-supply reservation and shipment
1. Our delivery times are to be understood as being approximate.
2. Our delivery times are to be understood ex works or ex stock. They are in any case
subject to the fulfillment of the contractual obligations by the customer. Any subsequent
amendment or supplement requested by the customer shall postpone the delivery time
accordingly.
3. Our delivery commitment shall be subject to self-supply. Even though delivery times are
contractually agreed upon, we shall not be responsible for any delays in shipment or
servicing caused by force majeure and/or events complicating the delivery or making
it impossible, such as unforeseeable difficulties occurred in procuring material, shortage
of raw material, official actions, strike, lockout, etc., even if they occur to our suppliers
or their sub suppliers. They entitle us to postpone the shipment by the duration of the
impediments plus a reasonable start-up time or to withdraw from the contract in case
of impediments which turn out to be of longer duration.
4. A declaration supplied by our supplier or a sub supplier shall be a sufficient proof that
we are prevented from supplying or servicing.
5. Partial shipments shall be possible. Each partial shipment is considered an independent
transaction and does not affect the unfulfilled part of the contract. We are at any time
entitled to partial shipments or services.
VI. Place of performance, shipment and passing of the risk
1. Place of performance is for both parties the seat of our company.
2. Loading and shipment shall be made to the best of our discretion and always at the
customer`s risk. The risk passes on as soon as we have shown the readiness for dispatch,
at the latest with the beginning of the loading onto the means of transport. The same shall
apply if shipment is made free of charge.
3. In case of transport damages, it is up to the customer to immediately arrange with the
authority in charge for an ascertainment of the facts as otherwise possible claims against
the transporting or insurance company gets lost.
VII. Failure to take on delivery
1. In case of the customer`s default in taking delivery, we are, after unsuccessful expiration
of an adequate period, entitled to either refrain from the contract or to claim
indemnification because of non-fulfillment to an amount of 20% of the order value
(unless the customer evidences that the damage involved is considerably lower or that
there is no damage at all). The assertion of an effectively higher claim remains reserved.
VIII. Terms of payment
1. Our invoices are payable either within 10 days with 2% discount or within 30 days from
date of invoice net. Discount shall only be granted if all previous payment obligations
have been met. In special cases we reserve the right to ask for advance or immediate
payment.
2. We are entitled to charge from the due date on default interests at a rate of 4% above the
discount rate as stipulated by the Deutsche Bundesbank. The assertion of additional
compensations for additional damages caused by the default shall not be affected.
3. If an order is executed in several shipments, we shall be entitled to invoice the
individual shipments separately. In case of delay in payment, we shall have the right
to discontinue the supply until payment is made.
4. We accept eligible bills only upon expressive agreement and for the sake of payment. Any
costs and expenses involved shall be paid for by the customer. Bills and cheques are only
credited after clean receipt of the net value and only to the amount of the same.

Updates under: www.concab.agb.de

5. All our claims shall regardless of any terms of payment, deferment or the life of any bills
or papers received, become due immediately if any circumstances (e.g. protest of bills,
payments in arrears) which may in our opinion affect the credit-worthiness of the
customer comes to our knowledge. We can in this case demand an immediate advance
payment and adequate securities for any outstanding supplies and services or withdraw
from the contract.
6. If a customer discontinues his payment, becomes bankrupt or aims at the institution
of composition proceedings, any discounts, allowances or other price reductions granted
on outstanding claims shall be regarded as not being granted.
7. As far as the order belongs to the operation of a commercial business of the customer, the
same shall not be authorized to enforce a lien.
8. The setting off of disputed claims that have not been recognized by declaratory
judgment is excluded.
IX. Reservation of the right ownership
1. All goods supplied to the customer shall remain our property until full payment of all our
claims, even if the purchase price of specifically denominated claims has been settled.
2. We are the owner of the reserved goods, the customer is the custodian. The customer
is as custodian above all obliged to secure and care for the goods properly, making sure
that no property or person can be exposed to danger. Any possible risks have to be
covered adequately by insurances.
3. The handling and use of the reserved goods is done for us as manufacturers in the
meaning of 950 BGB (German Civil Code), however, without engaging us. The used
goods are considered to be reserved goods.
4. If the reserved goods are handled, mixed or connected with reserved goods of other
suppliers, the customer assigns his ownership or co-ownership to CC.
5. The customer shall until revoked be allowed to resell the goods supplied by us and the
articles resulting from their processing in proper business dealings.
6. The customer assigns us as security all claims resulting from the resale to the amount of
our full purchase price claim until the full redemption of all our claims. As far as the
goods have been handled, mixed or mingled, the assignment shall be made in proportion
of the reservation of ownership to the value of all goods. If the customer has sold the
claim within a real factoring, he shall assign us the claim taking its place against the
factor. The reservation of ownership shall also remain in force if some of our claims are
included in a current invoice; the balance is struck and accepted. The reservation of
ownership is due to us not only for the accepted and abstract final balance, but also for
the causal balance. The customer shall assign us the claims on the balance in the
meaning of 355 HGB (Commericial Code) in the amount of the claims being due to us.
If the value of the securities given to us exceeds out total claims by more than 10%, we
shall release securities of our choice upon customer`s request.
7. The customer shall be entitled to collect assigned claims as long as he meets his
financial obligations with us in accordance with the contract and his property is not
subject to forfeiture. He shall in any case no longer be entitled to collection if we
withdraw the authorization or disclose the assignment. The customer shall not be entitled
to dispose otherwise of the reserved goods (e.g. pledging, assignment as security for
a debt). The customer shall upon our request be obliged to inform us about all assigned
claims, above all to supply us a list showing the debtors with name, address, amount
of the claims, date and number of the invoices as well as any existing global assignments.
8. The customer`s right to own reserved goods expires if he gets into arrears concerning his
obligations toward us or if circumstances occur which justify according to article VIII,
item 5, an immediate maturity acceleration of our claims. The customer shall upon
request return the reserved goods at his expense. As indirect owners of the reserved goods
we have also the right to enter the customer`s premises and to take the reserved goods as
security, which cannot automatically be considered a withdrawal from the contract. We
are entitled to claim and utilize assets of the customer which are subject to our direct
influence as security.
X. Warranty
1. We only supply goods that meet the current state of technical development. As far as
standards (DIN) or other regulation (VDE) are available, we supply goods that have been
manufactured according to these regulations.
2. The goods supplied by us have to be checked for defects immediately upon receipt at the
place of destination, also if samples had been sent. The shipment and/or service is
considered accepted if we are not given written notice of obvious defects or defects
detected during the inspection within a preclusive period of eight days after arrival of the
goods at the place of destination, but in any case before connection, installation or
processing. The notice shall in any case show the delivery note and invoice number.
3. Our warranty is limited to rectifications of defects respectively replacements of our
choice. The customer has to give us time and occasion in an adequate way.
If rectifications of defects or replacements turn out to be obviously unsuccessful or if we
reject the remedy of a defect because of disproportionately high expenses, the customer
shall have the right of claiming either a compensation or withdrawing from the contract.
4. Warranty claims are subject to a limitation period of six months after passing of the risk,
in case of acceptance after the acceptance. A rectification of defects or replacement does
neither suspend nor interrupt the limitation period of warranty claims.
5. We shall not be responsible for damages being due to improper handling and storing, faulty installation or natural wear. Repair works or other interventions carried out by the
customer or third parties without our consent shall exclude any warranty.
6. Replaced parts shall be our property.
XI. Liability
1. Claims for indemnification are, with exception of the restrictions mentioned under the
following item, excluded regardless of their legal grounds, provided they are not subject
to a grossly negligent or willful violation of our contractual obligations.
2. In case of our delay or failure to supply, for which we are responsible, our obligation for
indemnification shall be limited to 10% of the value of the part of supply in question. This
does not affect our liability concerning characteristics guaranteed by us.
3. We are not liable for indirect or consequential damages.
4. All claims for indemnification, for whatever legal ground, are subject to a limitation
period of six months after passing of the risk, in case of acceptance after the acceptance.
5. Any written or verbal suggestions concerning use or models are made to the best of our
knowledge. They are not binding and no responsibility is taken. They do by no means
release the customer from own tests or inspections.
XII. Binding force of a contract, place of jurisdiction
1. The ineffectiveness of individual contractual regulations does not affect the validity of the
remaining regulations. The customer and the supplier agree to secure as far as
possible the economic success aimed at an ineffective clause in another legally
admissible way.
2. Jurisdiction for all rights and obligation, also from bills and cheques, is at our choice
Schwbisch Hall or Heilbronn, as far as customers are merchants who have been entered
as merchants in the commericial register, legal persons under public law or persons who
have no general jurisdiction in Germany. This does also apply to those being liable for the
customer`s obligations. We are in any case entitled to take also legal actions at the
customer`s seat.
XIII. Redelivery of goods abroad
1. In case our domestic customer redelivers abroad, the customer shall be responsible to
observe the necessary restrictions of possible external trade law of the Federal Republic
of Germany, the Dual-Use Decree of the EC, the external trade law of the US or any other
external trade law of the country to be exported to.
XIIII. Others
1. Return of goods is only accepted after previous written agreement.
Handling - and freight charges to the debit of the customer.
2. For construction - and program alterations all rights reserved by ConCab.
3. In case of resell by a German customer into a foreign country, the German customer needs
to investigate whether the exported goods confirm to the restrictions under the Foreign
Trade and Industry Law of the German Federal Republic. The exporter himself is
responsible for observing the appropriate regulations.
With the date of publishing these conditions of sale, all previous conditions will no longer
be valid. All offers are also based on these conditions of sale.

5/11

561

Am Moosbach 7-9
uerer Eichwald
D-74535 Mainhardt
Phone: +49 (0) 79 03 - 91 55 - 0
Fax:
+49 (0) 79 03 - 91 55 - 88
Email: info@concab.de
Internet: www.concab.de

ConCab customers
not only in Europe.

Even the longest


trip is worth it.

Anda mungkin juga menyukai