AEGIS

- Vacuum Circuit Breaker Ring Main Unit

ENGINEERING BRILLIANT SOLUTIONS

Aegis Vacuum Circuit Breaker Ring Main Unit


Designed for secondary distribution networks up to 24kV, and rated currents up to 630A, the Aegis range of vacuum circuit breaker ring main units (RMU) provides a comprehensive series of solutions which lend itself to numerous applications for utilities, compact secondary substations, mining and commercial buildings. It is available for both indoor and outdoor environments protected against the harshest of conditions without the need for additional housings.

Used at the secondary distribution level primarily for distribution of power and for the protection of local transformers. It is suitable for heavy duty operation with a long service life and virtually zero maintenance. It can be used either as a freestanding unit or installed in compact mini-substations and kiosks.

Key features
12kV, 17.5kV and 24kV versions Compact one tank solution Intuitive mimic diagram Vacuum interrupters for circuit breakers Pre-wired for motor actuation and remote indication Integral cable testing from front of the unit Common stainless steel switching chamber Hermetically sealed switching chamber DIN 400 C-bushings as standard on all circuits Indoor and outdoor application Superior electrical performance - in excess of IEC requirements Transformer over current protection for phase to phase faults

Benefits
Front accessed cable box suitable for disconnectable cable terminations Fully interlocked for safe operation Maintenance free Easy to install Simple operation Suitable for mini substation Configured for future automation applications Climate-independent Proven technology No Kiosk required Cost effective

1 Lifting lugs 2 Sealed tank 3 Switch blades 4 Vacuum interrupters 5 Internal arc vent 6 Primary earth point 7 Fully interlocked test access cover

8 Cable test terminals 9 Pressure gauge 10 Facia and mimic 11 Circuit breaker or ring switch operation 12 Cable termination 13 Cable box

Design
The Aegis ring main unit is available with up to 4 functions in one common tank. It can be configured with vacuum circuit breaker units or a combination of vacuum circuit breakers and fault-make load break switches.

Options
Circuit Breaker Protection
Circuit breaker protection can be achieved via ring core current transformers in combination with Time Limit Fuse or a range of protection relays.

Stainless Steel Gas Enclosure


Highest quality stainless steel switching enclosure.

Cable Boxes
Internal arc tested cable boxes are available for IEC 62271 specifications. Interlocked cable boxes are also provided as options.

Housing
Fully treated, to resist weather and pollution attacks. Outdoor units are provided with a hinged, weatherproof and lockable cover.

Automation
Pre-wired for automation. Rotary actuators can be easily and rapidly fitted on site whilst the unit is in service no access is required to the internal workings of the Aegis.

Circuit Breaker
Comprises 3 vacuum interrupters for fault-make, fault-break rating.

Remote Trip Coil Push to trip Earth Fault Indicator

Switches
Switching available via single break 3 position switches providing ON, OFF and EARTH positions.

Operation
Operated via manually independent mechanisms mounted external to the gas enclosure, status is clearly identified through mimic diagram on front panel.

Safety
Hermetically sealed, touch safe units ensures maximum operator safety. Mimic diagram representation minimising language issues. Voltage Presence Indicator System (VPIS) clearly identifies when circuit is isolated from supply.

Test Facilities
Fully interlocked test facilities are provided in accordance with IEC62271 requirements, standard on ring switch, optional on circuit breaker.

Interlocks
Positive, intuitive, clear and simple safety interlocks are incorporated on all switch positions to prevent mal-operation.

Quality
ISO 9000 quality systems approved. Proven technology. FMEA (failure mode evaluation analysis) designed.

Padlocks
All switch and selector positions can be padlocked to prevent unauthorised access

Typical Configurations and Dimensions


3-way 4-way

Typical Schematic Line Diagram


3-way 4-way

Technical Data
(ratings in brackets are optional)

12kV

17.5kV

24kV

Rated Voltage Frequency Impulse Withstand Voltage Normal Current Ring Switches Circuit breaker Short Circuit Peak making Current Ring Switches Circuit Breaker Short Circuit breaking Current Circuit Breaker Short Time Current Ring Switches Circuit Breaker Earth Switch Peak Making Current Ring Switches Circuit Breaker Internal Arc Rating Freestanding Substation Optional Cable Boxes internal Arc Rating Gas Pressure Min Operating Pressure IP Rating Testing Standards IEC 60265-1 IEC 62271-100 IEC 62271-102 IEC 62271-200

12kV 50Hz 75 kVp 630A 250A(630A) 50kA 50kA 20kA 20kA for 3 sec 20kA for 3 sec 50kAp 7.9kAp(50kAp) 20kA 1sec 20kA 1sec 20kA 1 sec 0 Bar IP4X(IP54W option)

17.5kV 50/60Hz 95kVp 400A 200A 54.6kA 54.6kA 21kA 21kA for 1 sec 21kA for 1sec 54.6kAp 54.6kAp 21kA 1sec 21kA 1sec 21kA 1sec

24kV 50Hz 125kVp 400A 250A(400A) 40kA 40kA 16kA 16kA for 3 sec 16kA for 3 sec 40kAp 7.9kAp(40kAp) 16kA 1sec 16kA 1sec 16kA 1sec

0 Bar 0.4 Bar IP4X(IP54W option) IP4X(IP54W option)

Lucy Switchgear Howland Road, Thame, Oxfordshire, OX9 3UJ, UK tel: +44 (0)1844 267267 fax: +44 (0)1844 267223 email: sales@lucyswitchgear.com

Lucy Middle East PO Box 17335, Jebel Ali, Dubai, United Arab Emirates tel: +9714 812 9999 fax: +9714 812 9900 email: sales@lucyme.ae

The Saudi Lucy Company Ltd PO Box 834, Al-Khobar, 31952, Saudi Arabia tel: +966 3 8823057 fax:+ 966 3 8822553 email: info@saudilucy.com

Lucy South Africa Suite 22, Fourways Business Centre, Design Quarter, Nicole Grove Office Park, Leslie Road, Fourways 2005, South Africa tel: +27 (0)11 5133415 tel: +27 (0)11 5133000 fax: +27 (0)86 6783418 email: salesza@lucyswitchgear.com

Lucy Asia Pacific Sdn Bhd Suite 32-01-92, 32nd Floor, Wisma Keck Seng, 203 Jalan Bukit Bintang, 55100 Kuala Lumpur, Malaysia tel: +603 2116 5640 fax: +603 2116 5647 email: abdul.latif@lucyswitchgear.com

www.lucyswitchgear.com

LS00001 AEGIS 04 2010 (1000) 7642

Anda mungkin juga menyukai