The ERV-24 brings you the cutting


edge in technology into an
extremely simple 24Vac thermostat.
FanCycler

methods are
incorporated into the attractive,
surface mounted thermostat which
has a large, easy-to-read, display.
24VAC Surface Mount Thermostat
With FanCycler

Applications
Main Supply 24Vac
Fresh Air Damper output - 24Vac Power
Open / Spring close
Remote sensor connection or Average option
Offset for temperature reading adjustment
Lock buttons (Tamper proof)
Data Storage Diagnostics
FanCycler

build in
DIP Switch/Jumper selection
Programmable or non Programmable
Auto Change-Over or Manual Heat-Cool
Compressor 3 minute delay
Fan Mode (Electric or Oil/Gas)
f08l0f08
600f8l
Web: www.scillc.com | e-mail: info@scillc.com Pg.1
Protected by U.S. patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135
Speeds Heat Stages Cool Stages Model
1 1 1 ERV-24-HC11
N000l8
ERV-24-HC11 FanCycler.PPT
Rev. 2 Date: 15.12.2004
Fan Coil Thermostat
ll00lfl08l 0l8f8M
Remote
Sensor
(Optional)
24Vac
Fresh Air Damper Power open/Spring close
Fan
Heat
Compressor
80M0l0 $080f8 0000ll08 0ll08
RS01
Temperature
sensor
Thermostat
T T
RS02
Average
Temperature
sensor
Thermostat
T T
Option 1 Option 2
RS02
Average
Temperature
sensor
Web: www.scillc.com | e-mail: info@scillc.com Pg.
Protected by patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135
Thermostat
C FD RC RH T T W1 G Y1
f800l0f

- 00ll0f80l0 f08l0f08
Combo system pump cycling (multi-family application)
Fan Cycling availability at night in heating mode
Fan over-run after cooling operation
Ventilation damper cycling
Fan cycling
08l8 $l0f80 0l808ll08
Average length of heating cycle
Average length of cooling cycle
Average number of heating cycles per day (while in heating mode)
Average number of cooling cycles per day (while in cooling mode)
Average heating set point (while heating is active)
Average cooling set point (while cooling is active)
ERV-24-HC11 FanCycler.PPT
Rev. 2 Date: 15.12.2004

0lM08l08

$00lll08ll08
000880fl08
Temperature Input Thermistor 50K@77F
Flammability UL94V-0
Plastic PC/ABS
Accuracy 1.5F
Color White
Scale F
Weight 0.3 Lbs. / 0.125 Kg
Temperature Range 50F - 90F
Temperature Average Sensor into decorative box RS02
WP4
RS01
TS01
Part Number
Decorative Back Plate for ERV
Temperature Sensor into decorative box
Temperature Sensor 30 Inch Cable
Description
Protected by patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135
Web: www.scillc.com | e-mail: info@scillc.com Pg.
TS01
RS01
RS02
92mm
80mm
Front view Side view
22mm
80mm
WP4
ERV-24-HC11 FanCycler.PPT
Rev. 2 Date: 15.12.2004
Protected by patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135
Web: www.scillc.com | e-mail: info@scillc.com Pg.4
000l
The ERV-24-HC11 thermostat with FanCycler

has enhanced features to compliment


controlled mechanical ventilation systems. These features were configured by your
installing technician. A brief summary description follows:
FAN CYCLING CONFIGURATION The purpose of fan cycling is to assure that the
central air handler fan will run enough to distribute ventilation air and evenly mix air
throughout the house when there is no demand for heating or cooling. Rather than
operate the fan continuously or by a simple timer that cant consider prior operation, the
FanCycler

method saves energy and wear and tear on equipment by only operating the
fan if it hasnt already operated enough.
VENTILATION DAMPER CYCLING The purpose of cycling the ventilation damper is to
limit the possibility of over-ventilating during peak-load conditions which could cause
unnecessary space conditioning energy consumption. If the fan stays on longer than
needed for the introduction of ventilation air, the damper will automatically close.
600f8l l800l
ERV-24-HC11 FanCycler.PPT
Rev. 2 Date: 15.12.2004