Anda di halaman 1dari 38

FEDERAL

L POWERTM

PR
RODU
UCTCA
ATALO
OG

X LP
XL
PE
XL
LPEInsulaatedPow
werCabless

F
Federal
Pow
wer Sdn Bhd
d (17892 -V)
Lot 8, Jln Rag
gum 15/17, P.O
O.Box 7016
40702 Shah
S
Alam, Sellangor
W
West
Malaysia
Tel (603
3) 5518 3600/6
601/602
Fax (603) 5512 27
730
(603) 5519 80
020
W
Website:
http:///www.federalpo
ower.com.my
E
Email:
commerrcial@federalpo
ower.com.my

Designed by
b : Information Syystems Dept

XLPE
CONSTRUCTION

600/1000V XLPE/PVC Power Cable

Conductor
Insulation
Fillers
Binder tape
Outer sheath

3.6/6-18/30 kV XLPE/PVC Power Cable


Conductor
Conductor shelding
(Semi-conducting layer)
Insulation
Insulation shielding
(Semi-conducting layer)
Metallic shielding
Fillers
Binder tape
Outer sheath
Single core

Three core

600/1000V XLPE/SWA/PVC Power Cable

3.6/6-18/30 kV XLPE/SWA/PVC Power Cable


Conductor
Conductor shielding
(Semi-conducting layer)

Conductor
Insulation

Insulation

Fillers

Insulation shielding
(Semi-conducting layer)

Binder tape
Separation sheath

Metallic shielding

Steel wire armour

Fillers

Outer sheath

Binder tape
Separate sheath
Steel wire armour
Outer sheath

Notes: SWA : Steel wire armoured

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
1

XLPE
CONSTRUCTION

11kV up to 33kV AI-XLPE/SWA/PE Cable

Conductor; Hard drawn aluminium


Conductor shielding
Insulation: XLPE
Insulation shielding
Metallic shielding: Copper tape
Fillers
Binder tape
Bedding: Black polyethylene
Armour : Galvanized steel wire
Outer sheath: Black polyethylene

11kV up to 33kV AI-XLPE/PE Aerial Cable

Conductor
Conductor shielding
Insulation
Insulation shielding
Metallic shielding
Binder tape
Sheath: Black HDPE
Messenger wire
: Galvanized steel wire

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
2

XLPE
CONSTRUCTION
Cross-section of 600/1000 V AI-XLPE/SWA/PE Cable

Conductor: Hard drawn aluminium, sector shape


Insulation: XLPE
Fillers: Polypropylene yarn
Binder tape: Plastic tape
Bedding: Black polyethylene
Armour: Galvanized steel wire
Outer sheath: Black-termite repellent polyethylene

Core identification : Core identification shall be made by coloured insulation compound. Cable
identification : Outer sheath shall be embossed.

Cross-section of 11 kV up to 33 kV AI-XLPE/PE Aerial Cable

Conductor : Hard drawn aluminium


Conductor shielding
Insulation : XLPE
Insulation shielding:
Metallic shielding:
Annealed copper tape
Sheath: Black HDPE
Messenger wire:
Galvanized steel wire

Cross-section of 11 kV up to 33 kV AI-XLPE/SWA/PE Cable


Conductor: Hard drawn aluminium
Conductor shielding
Insulation: XLPE
Insulation shielding
Metallic shielding
Fillers: Polypropylene yarn
Binder tape
Bedding: Black polyethylene
Armour: Galvanized steel wire
Binder tape
Outer Sheath: Black termite repellent polyethylene

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
3

XLPE
11kV up to 161kV XLPE/PE Cable with Copper wire screen

CONDUCTOR
(Copperoraluminium)

CONDUCTORSHIELD

INSULATION(XLPE)

INSULATIONSHIELD
SWELLABLETAPE
METALLICSCREEN
(Copperwires)
BINDINGTAPE

OUTERSHEATH

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
4

XLPE
11kV up to 132kV XLPE/LC/PE or PVC cable with lead sheathed

CONDUCTOR
(Copper or aluminium)

CONDUCTOR SHIELD

INSULATION (XLPE)

INSULATION SHIELD

LEAD SHEATH

OUTER SHEATH

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
5

XLPE
11kV up to 132kV XLPE/AWA/PE or PVC cable with Aluminium wire screen

CONDUCTOR
(Copperoraluminium)

CONDUCTORSHIELD

INSULATION(XLPE)

INSULATIONSHIELD

SWELLABLETAPE

METALLICSCREEN
(Aluminiumwires)
BINDINGTAPE

OUTERSHEATH

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
6

XLPE
Technical Data
CONTINUOUS CURRENT CARRYING CAPACITY
The tabulated current rating have been calculated in accordance with IEC 287. They are for single circuit with the standard conditions
as follow:i) Maximum permissable conductor temperature at continuous operation is 90 deg. C
ii) Ground temperature is 25 deg.C
iii) Ambient temperature is 40 deg.C
iv) Ground thermal resistivity is 1.2 Km/W
v) Cables laying depth is ground:- cables voltage up to 1kV500mm
- cables voltage above 1kv800mm
vi) Spacing between cables:-In flat formation.2 times of the cable overall diameter.
-In trefoil formation.cables touching.
vii) Cables sheath or armour solidly bonded at both ends
viii) Cables shielded from direct sun rays
For conditions of operation different from those on which the continuous current carrying capacity tables are based, ratings can be
determined by application of Rating Factor in table below.

Rating Factor
Rating Factor For Cables In Air
Ambient air temperature

10

15

20

25

30

35

40

45

50

55

60

Rating Factor

1.26

1.22

1.18

1.14

1.10

1.05

1.00

0.95

0.89

0.84

0.78

Rating Factor For Ground Temperature


Ground temperature

10

15

20

25

30

35

40

45

50

55

60

Rating Factor

1.11

1.07

1.04

1.00

0.96

0.92

0.88

0.83

0.78

0.73

0.68

Rating Factor For Thermal Resistivity of Ground


Thermal Resistivity (K.m/W)
Conductor size (mm2)
0.8

0.9

1.0

Single Core Cable


Up to 150
From 185 to 400
From 500 to 1200

1.16
1.17
1.18

1.11
1.12
1.13

1.07
1.07
1.08

Multicore cables
Up to 16
From 25 to 150
From 185 to 400

1.09
1.14
1.16

1.06
1.10
1.11

1.04
1.07
1.07

1.2

1.5

2.0

2.5

3.0

1.0
1.0
1.0

0.91
0.90
0.90

0.81
0.80
0.79

0.73
0.72
0.71

0.67
0.66
0.65

1.0
1.0
1.0

0.95
0.93
0.92

0.86
0.84
0.82

0.79
0.76
0.74

0.74
0.70
0.68

Rating Factor For Depth of Laying


Depth of laying
(m)
0.50
0.60
0.80
1.00
1.25
1.50
1.75
2.00
2.50
3.0 or more

1.9 / 3.3 kV to
19 / 33 kV cables

0.6 / 1 kV cables
up to 50mm2

70mm2 to 300m2

above 300mm2

up to 300mm2

1.00
0.99
0.97
0.95
0.94
0.93
0.92
0.91
0.90
0.89

1.00
0.98
0.96
0.94
0.92
0.91
0.89
0.88
0.87
0.86

1.00
0.97
0.94
0.92
0.90
0.89
0.87
0.86
0.85
0.83

1.00
0.98
0.96
0.95
0.94
0.92
0.91
0.90

above 300mm2
1.00
0.97
0.95
0.94
0.92
0.90
0.89
0.88

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
7

XLPE
Group Derating Factors
Multiple circuits

Derating Factors for groups of cables installed in air


Number vertically

Number of cable horizontally


Spacing

S=d
S = 2d
S = 3d

7-20

8-20

1.00
1.00
1.00

0.85
0.95
1.00

0.80
0.95
1.00

0.70
0.80
0.95

0.70
0.80
-

0.70
0.90
0.95

0.60
0.90
0.95

0.60
0.85
0.90

0.56
0.73
-

0.53
0.72
-

0.51
0.71
-

0.50
0.70
-

9-10

11-12

13-15

16-19

20

N/A

0.48
0.80
0.85

0.41
0.80
0.85

0.37
0.68
-

0.34
0.66
-

0.32
0.65
-

0.31
0.65
-

0.30
0.64
-

0.30
0.63
-

0.30
0.62
-

0.30
0.61
-

0.30
0.60
-

Number vertically

Number of cables horizontally


Spacing

S=d
S = d2
S = 3d

Number of cables horizontally


+

Number vertically

S
S

Derating Factors for groups of cables laid direct in ground


Cable
Voltage
(kV)

0.6/1

1.9/3.3 to 12.7/22

19/33

Number
of
circuit

Trefoil

Laid flat

2
3
4
5
6
2
3
4
5
6
2
3
4
5
6

0.77
0.66
0.59
0.55
0.52
0.78
0.66
0.60
0.55
0.52
0.79
0.67
0.62
0.57
0.54

0.80
0.68
0.63
0.58
0.56
0.80
0.69
0.63
0.58
0.55
0.81
0.70
0.65
0.60
0.57

S
Three single core cables in trefoil and laid flat touching, horizontal
formation
Spacing of circuit (between centres of cables groups)

Touching

0.15m*

0.3m

0.45m

0.6m

0.82
0.72
0.67
0.63
0.60
0.81
0.71
0.65
0.61
0.58
0.81
0.71
0.65
0.60
0.57

0.88
0.79
0.75
0.72
0.70
0.85
0.76
0.72
0.68
0.66
0.85
0.76
0.72
0.68
0.66

0.90
0.83
0.81
0.78
0.77
0.88
0.80
0.76
0.73
0.72
0.88
0.80
0.76
0.73
0.72

0.93
0.87
0.85
0.83
0.82
0.90
0.83
0.80
0.77
0.76
0.90
0.83
0.80
0.76
0.76

* This spacing will not be possible for some of the larger diameter cables.

Multicore cables in horizontal formation

Derating Factors for groups of cables laid direct in ground

Spacing of circuits (between centres of cable groups)

Cable
Voltage
(kV)

Number
Of
circuits

Touching

0.15m*

0.3m

0.45m

0.6m

0.6/1

2
3
4
5
6

0.81
0.70
0.63
0.59
0.55

0.87
0.78
0.74
0.70
0.67

0.91
0.84
0.81
0.78
0.76

0.93
0.87
0.86
0.83
0.82

0.94
0.90
0.89
0.87
0.86

1.9/3.3 to 12.7/22

2
3
4
5
6

0.80
0.69
0.63
0.57
0.55

0.85
0.75
0.70
0.66
0.63

0.89
0.80
0.77
0.73
0.71

0.90
0.84
0.80
0.78
0.76

0.92
0.86
0.84
0.81
0.80

19/33

2
3
4
5
6

0.80
0.70
0.64
0.59
0.56

0.83
0.73
0.68
0.63
0.60

0.87
0.78
0.74
0.70
0.68

0.89
0.82
0.78
0.75
0.74

0.91
0.85
0.82
0.79
0.78

* This spacing will not be possible for some of the larger diameter cables.

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
8

XLPE
Handling and installation of XLPE cable

1.

Minimum bending radius and permissible maximum pulling tension.


For safety installation without damaging electrical and physical properties, the following minimum bending radius and permissible
maximum pulling tension must be observed.
Minimum bending radius

D: Overall dia. Of cable

Number of core

Single core
Multi core
Round conductor

Four segmental stranded conductor

600 V cable

10D

12D

8D

3,300 V cable and higher

10D

12D

8D

8D

Corrugated metal armoured cable

10D

12D

8D

Flat tape armoured cable

10D

12D

8D

Wire armoured cable

10D

12D

10D

Lead sheathed cable

10D

12D

10D

Type of cable

Triplex type cable

Permissble maximum pulling tension


Pulling tool

Material of conductor

Pulling eye

Copper

7 x (Number of core) x (Core-sectional area of conductor)

Aluminium

4 x (Number of core) x (Core-sectional area of conductor)

Cable grip

Copper & aluminium

Permissible maximum pulling tension (kg)

The same as using the pulling eye, but the minimum tension should be less than
two tons

Note : When cable grip is used it should cover more than 500 mm in length of end be bound to the cable sheath.

2. Side wall pressure to cable


Permissible maximum side wall pressure to the cable at
bending point during installation is 500 kg/m.
Note :
Side wall pressure to cable

pulling tension (kg) = T


bending radius (m)

3. Removal of sheath or tape


Special care must be taken not to harm the insulation
when removing the sheath or tapes with knife otherwise
it may results in a dielectric breakdown.
4. Cleaning the surface of insulation
The surface of insulation should be cleaned to avoid a
flash over at the cable termination or joint.
5. Applying of self-adhesive tape
When applying a self-adhesive tape after joint or
terminating of XLPE cable, stretch it properly about 1.2
times as long as the original one. If it is over-stretched
crack may occur on the tape will not be adhered
between each layer.

T : Pulling tension (kg)


R : Bending Radius (m)

6. Water proof treatment for out-door termination


For out-door termination water proof treatment is
necessary to avoid the water penetrating into the cable
end and special care must be taken to apply tapes
and terminals. It is desirable to use a compression to
solder type terminal.

Side wall
pressure

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
9

XLPE
DIMENSIONAL
TABLE XLPE / PE or PVC

For Aluminium and Copper Conductor


600/1000 V XLPE/PE Power Cable, Type XLPE/PE
Conductor

Nominal

Shape

mm

thickness
of
sheath
mm

Thickness
of
sheath
mm

Approximate
overall cable
diameter
mm

Approx.
weight
(Cu)
kg/km

Approx.
weight
(AL)
kg/km

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.1
2.4
2.6

1.5
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.3
2.4
2.6

16
17
19
20
21
23
25
26
28
31
34
37
41
45
50

400
510
630
790
1010
1280
1540
1860
2210
2790
3420
4430
5460
6760
8450

300
350
400
470
570
680
790
910
1050
1280
1530
1550
2300
2780
3400

39.0

2.8

2.7

54

10410

4100

Nominal
cross sectional
area
sqmm
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

Diameter

Compact
round
stranded

1000

Single core

600/1000V Multi-core XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom. Cross

Three core

Thickness

Thickness

Diameter

of

of

area
sqmm

mm

insulation
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8
39.0

sectional

Shape

Compact
round
stranded

1000

sheath
mm

Approx.
overall
cable
diameter
mm

0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6

1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.7
3.0
3.3
3.7
4.0

2.8

4.4

Four core
Approx.

Approx.

Thickness

sheath
mm

Approx.
overall
cable
diameter
mm

weight

weight

of

(copper)
kg/km

(alu)
kg/km

18
22
24
27
31
35
38
43
47
53
59
66
74
84
95

670
990
1320
1810
2450
3220
4000
5000
6070
7780
9620
12670
15720
19720
24920

106

Approx

Approx.

weight

weight

(copper)
kg/km

(alu)
kg/km

360
510
640
840
1100
1390
1690
2070
2500
3150
3830
4930
6070
7560
9480

1.8
1.8
1.8
1.8
2.0
2.1
2.3
2.4
2.6
2.8
3.0
3.2
3.5
3.8
4.2

19
23
26
29
34
38
43
47
52
59
66
74
83
94
106

890
1320
1750
2370
3230
4260
5320
6590
8070
10340
12780
16800
20890
-

480
670
850
1080
1430
1820
2230
2730
3310
4160
5060
6510
8020
9960
12490

11650

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
10

XLPE
DIMENSIONAL
TABLE, XLPE / PE or PVC
`

0.6/1 kV-XLPE/PE.LV-Continuous Current Rating Factor (100%-Load)


in-air at 400C

Conductor

Aluminium

in-ground at 300C
Copper

Size

Aluminium
3

in-duct

Copper
3

conductor

Aluminium

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper

Single

or

Single

or

Single

or

Single

or

Single

or

Single

or

Core

Core

Core

Core

Core

Core

Core

Core

Core

Core

Core

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

mm

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

16

95

85

75

125

105

100

90

90

85

115

110

110

80

80

60

105

100

80

1.5

2.3

25

130

130

100

165

145

130

115

115

110

150

145

140

105

100

80

135

130

105

2.3

3.5

35

160

160

125

200

175

160

140

135

130

180

170

170

125

120

95

160

155

125

3.3

4.9

50

190

190

150

240

210

195

160

160

155

210

205

200

145

140

115

185

185

150

4.7

7.0

70

235

235

190

305

265

245

200

195

190

255

250

245

180

175

140

230

225

185

6.7

9.9

95

290

290

235

370

320

300

235

230

235

305

295

295

220

220

170

285

280

220

9.1

13.4

120

335

335

270

430

370

345

270

260

260

345

335

335

255

250

195

325

320

250

11.4

17.0

150

385

385

305

500

430

395

300

295

290

390

380

375

285

280

220

370

360

285

14.3

21.2

185

445

445

350

570

495

450

340

330

330

440

425

420

325

320

250

420

410

320

17.7

26.2

240

530

530

415

680

585

530

395

385

380

510

490

485

380

370

305

485

475

390

22.9

34.0

300

605

605

475

780

670

605

450

435

425

575

555

545

425

420

345

550

535

435

28.7

42.5

400

710

710

555

910

780

695

515

495

490

660

630

615

490

480

395

630

610

500

38.3

56.7

500

835

835

640

1060

900

795

590

565

555

750

710

690

565

545

455

715

690

560

47.0

70.9

630

980

980

740

1235

1040

900

675

645

630

855

800

770

645

625

515

815

775

630

60.6

89.4

800

1140

1140

845

1425

1190

1010

775

730

710

965

890

845

735

705

580

920

865

695

76.6

113

1000

1320

1320

945

1620

1345

1105

875

815

780

1075

980

915

830

790

640

1020

945

750

95.7

141.9

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
11

XLPE
DIMENSIONAL TABLE, XLPE / PE or PVC

1.9/3.3 kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

thickness

Single core
Thickness

Approx.

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.4
2.6

1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.5

39.0

2.8

2.7

sectional

Shape

Compact
round
stranded

1000

Three core

Approx.

Approx.

Thickness

Approx

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

15
16
17
19
20
22
24
25
27
30
32
35
39
43
49

370
480
590
750
970
1240
1500
1810
2160
2730
3330
4310
5530
6640
8350

270
320
370
430
530
640
740
860
1000
1210
1430
1780
2170
2670
3310

1.9
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.7
2.9
3.0
3.2
3.5
3.8
4.2

28
32
33
36
40
43
47
50
53
59
64
71
79
88
100

1060
1400
1770
2270
2980
3830
4660
5650
6780
8590
10510
13630
16920
21190
-

750
920
1090
1310
1630
2000
2350
2750
3210
3950
4720
5910
7270
9030
11330

54

10340

4030

4.6

111

13890

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

3.8/6.6 kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

Single core

thickness

Thickness

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
3.2

1.5
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.3
2.4
2.6

39.0

3.2

2.7

sectional

Shape

Compact
round
stranded

1000

Approx.

Three core

Approx.

Approx.

Thickness

Approx

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

16
17
19
20
21
23
25
26
28
31
34
37
41
45
50

400
510
630
790
1010
1280
1540
1860
2210
2790
3420
4430
5460
6760
8450

300
350
400
470
570
680
790
910
1050
1280
1530
1550
2300
2780
3400

1.9
2.0
2.0
2.1
2.3
2.4
2.5
2.6
2.8
3.0
3.2
3.4
3.7
3.9
4.3

30
33
35
38
42
46
49
52
56
63
69
76
84
92
103

1160
1510
1890
2400
3120
3980
4820
5820
6960
8820
10860
14110
17450
21380
-

580
1030
1210
1430
1760
2150
2500
2920
3390
4190
5060
6390
7800
9410
11720

54

10410

4100

4.6

113

14170

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
12

XLPE
DIMENSIONAL
TABLE XLPE / PE or PVC

3.6/6 kV XLPE/PE.MV-Continuous Current Rating Factor (100%-Load)


0

Condu-

in-air at 40 C

ctor

Aluminium

in-ground at 30 C
Copper

Size

Aluminium
3

in-duct

Copper
3

conductor

Aluminium
3

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper
3

Single

or

Single

or

Single

or

Single

or

Single

or

Single

or

Isolated

Isolated

Isolated

Isolated

Isolated

Isolated

Core

Core

Core

Core

Core

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

(mm )

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

25

126

136

87

162

175

113

112

109

87

144

140

113

98

96

64

126

82

2.36

3.58

3.58

35

152

164

108

195

211

140

132

129

108

170

166

139

116

114

81

148

146

104

3.31

5.01

50

183

199

132

235

255

170

165

153

129

200

196

167

136

134

97

174

172

125

4.72

7.15

70

228

247

158

291

316

204

189

185

152

241

237

196

165

163

115

210

209

148

6.61

10

95

276

300

197

347

382

254

223

219

186

283

279

240

195

193

141

247

246

181

8.98

13.6

120

329

354

278

422

456

357

261

255

253

335

328

325

228

224

193

293

289

248

11.34

17.2

150

371

401

312

477

517

402

291

284

281

374

366

362

254

250

215

326

323

278

14.2

21.5

185

427

461

356

546

592

457

329

322

317

420

413

407

287

283

244

367

363

313

17.5

26.5

240

508

548

427

646

702

547

380

373

371

484

478

474

332

328

286

422

420

366

22.7

34.3

300

587

635

476

743

810

608

429

422

413

542

538

528

373

370

319

472

473

407

28.4

42.9

325

615

666

517

772

842

653

446

439

437

559

556

552

418

415

338

524

526

428

30.7

46.5

400

686

743

581

858

940

734

488

483

480

610

610

607

458

457

374

572

577

472

37.8

57.2

500

793

846

665

977

1080

829

552

55

545

679

687

680

517

520

446

636

649

556

47.2

71.5

630

899

1010

779

1087

1243

956

621

625

623

749

768

765

581

589

510

701

725

626

59.5

90.1

800

1045

1164

885

1237

1406

1066

689

702

698

813

847

841

643

660

573

759

797

690

75.6

114.5

1000

1160

1307

1026

1344

1548

1211

750

774

782

866

916

923

698

727

639

806

860

754

94.5

143.1

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
13

XLPE
DIMENSIONAL
TABLE, XLPE / PE or PVC

6.35/11 kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

thickness

Single core
Thickness

Approx.

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5

39.0

3.4

2.6

sectional

Shape

Compact
round
stranded

1000

Three core

Approx.

Approx.

Thickness

Approx

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

18
19
21
22
23
25
27
28
30
33
35
38
41
45
50

450
570
690
850
1080
1360
1630
1940
2300
2880
3490
4480
5490
6790
8490

350
410
470
540
640
760
870
1000
1140
1360
1600
1960
2330
2820
3440

2
2.1
2.1
2.3
2.4
2.5
2.7
2.8
2.9
3.1
3.2
3.5
3.7
4.0
4.3

34
37
39
42
46
50
53
56
60
66
71
77
84
93
104

1360
1730
2120
2640
3380
4270
5130
61400
7300
9160
11130
14310
17550
21780
-

1050
1240
1440
1670
2030
2430
2810
3250
3730
4520
5330
6580
7900
9620
11850

55

10440

4130

4.6

114

14320

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

8.7/15kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

thickness

Single core
Thickness

Approx.

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.7

39.0

4.5

2.8

sectional

1000

Shape

Compact
round
stranded

Three core

Approx.

Approx.

Thickness

Approx

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

21
22
23
24
26
28
29
31
32
35
37
40
44
48
53

530
650
780
940
1180
1460
1730
2060
2120
3000
3630
4630
5650
6960
8670

430
490
560
630
740
860
989
1110
1260
1490
1730
2110
2490
2990
3630

2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.0
3.2
3.4
3.6
3.9
4.1
4.5

40
42
45
47
51
55
58
61
65
71
76
82
89
98
109

1630
2020
2430
2970
3740
4650
5530
6570
7750
9650
11650
14880
18170
22460
-

1320
1540
1750
2000
2380
2820
3210
3670
4180
5020
5860
7150
8520
10290
12600

57

10650

4340

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
14

XLPE
DIMENSIONAL
TABLE, XLPE / PE or PVC

12.7/22 kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

thickness

Single core
Thickness

Approx.

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.7
1.7
1.8
1.8
1.9
1.9
2.0
2.0
2.0
2.1
2.2
2.3
2.4
2.6
2.7

39.0

5.5

2.9

sectional

Shape

Compact
round
stranded

1000

Three core

Approx.

Approx.

Thickness

Approx

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

23
24
25
25
28
30
31
33
34
37
40
42
46
50
55

610
730
860
1030
1280
1560
1840
2170
2540
3130
3760
4770
5800
7120
8850

510
580
640
720
830
960
1080
1220
1370
1620
1860
2250
2640
3150
3820

2.4
2.5
2.5
2.6
2.8
2.9
3.0
3.1
3.2
3.4
3.6
3.8
4.1
4.3
4.6

44
47
49
52
55
60
63
66
69
75
80
87
94
103
114

1740
2120
2510
3020
3770
4650
5500
6500
7640
9450
11380
14490
17640
21730
-

1430
1630
1830
2070
2420
2810
3180
3600
4060
4820
5580
6760
7990
9570
11600

60

10840

4530

Approx.

Approx.

weight

weight

(Cu)
kg/km

(AL.)
kg/km

19/33kV XLPE/PE Power Cable, Type XLPE/PE


Conductor

Nominal

Nom.
cross

thickness

Single core
Thickness

Approx.

Diameter

of

of

area
sqmm

mm

insulation
mm

sheath
mm

overall
cable
diameter
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3
26.4
30.2
34.8

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

1.9
2.0
2.0
2.0
2.1
2.1
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.8

39.0

8.0

3.0

sectional

1000

Shape

Compact
round
stranded

Three core

Approx.

Approx.

Thickness

Approx

weight

weight

of

(Cu)
kg/km

(AL.)
kg/km

sheath
mm

overall
cable
diameter
mm

29
30
31
32
34
36
37
39
40
43
46
49
53
57
62

840
970
1110
1290
1540
1840
2130
2470
2860
3470
4110
5150
6200
7560
9330

730
810
890
970
1100
1240
1370
1520
1690
1950
2220
2630
3050
3590
4280

2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.6
3.7
3.8
4.0
4.1
4.3
-

40
42
45
47
51
55
58
61
65
71
76
82
89
-

2420
2830
3250
3800
4580
5500
6390
7430
8610
10490
12480
15660
18900
-

2110
2340
2570
2830
3230
3670
4070
4530
5040
5860
6680
7940
9250
-

67

11350

5040

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
15

XLPE
DIMENSIONAL
TABLE, XLPE / PE or PVC

6.35/11kV to 19/33 kV-XLPE/PE.MV-Continuous Current Rating Factor (100%-Load)


Conductor

in-air at 40 C
Aluminium

in-ground at 30 C
Copper

Size

Aluminium
3

in-duct
Copper

conductor

Aluminium
3

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper
3

Single

or

Single

or

Single

or

Single

or

Single

or

Single

or

Isolated

Isolated

Isolated

Isolated

Isolated

Isolated

Core

Core

Core

Core

Core

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

mm

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

16

130

115

110

100

90

85

115

110

110

90

895

85

105

105

85

80

80

70

2.3

1.5

25

170

140

135

130

118

110

150

145

145

115

110

110

135

135

115

105

105

90

3.5

2.3

35

210

185

175

160

145

135

180

170

170

135

135

135

160

160

135

125

125

105

4.9

3.3

50

245

220

210

190

170

160

210

200

200

160

155

155

190

190

160

150

145

125

7.0

4.7

70

310

275

260

240

210

200

255

250

245

200

190

190

230

230

195

180

175

150

9.9

6.7

95

375

335

310

290

260

240

305

300

295

235

230

225

290

280

240

225

220

185

13.4

9.1

120

430

385

355

335

300

275

345

335

330

270

260

260

325

320

275

255

250

210

17.0

11.4

150

495

440

375

385

340

315

390

380

375

300

290

290

365

360

310

290

285

240

21.2

14.3

185

565

500

460

440

390

355

440

426

420

340

330

325

410

410

345

330

320

270

26.2

17.7

240

670

595

540

520

460

420

510

490

485

395

385

380

480

475

400

380

370

310

34.0

22.9

300

770

680

625

600

530

485

580

555

550

450

435

430

540

535

455

430

420

355

42.5

28.7

325

613

662

413

769

839

523

446

440

408

559

556

516

418

416

298

524

526

377

30.7

46.5

400

895

790

720

700

620

565

660

630

625

515

495

495

615

610

515

495

480

405

56.7

38.3

500

1040

910

810

820

720

645

750

720

705

590

570

560

695

680

580

556

530

465

70.9

47.0

630

1210

1050

940

960

840

755

850

810

795

680

650

640

785

770

655

650

630

530

89.4

60.6

800

1395

1200

1035

1115

975

855

970

905

875

775

735

720

875

845

720

735

710

595

113.0

76.6

1000

1590

1350

1125

1290

1115

960

1080

995

950

875

825

800

960

915

785

830

795

660

141.9

95.7

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
16

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

For Aluminium and Copper Conductor


600/1000 V Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor

Nominal

Thickness

Approx.

Diameter

Thickness

Approx.

Approx.

Approx.

thickness

of

cable diameter

of

of

overall

weight

weight

cross

of

separation

under

armour

outer

cable

(Cu)

(AL.)

sectional

insulation

sheath

wire

wire

sheath

diameter

Nominal

Shape

Diameter

area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

0.7

1.0

19

1.6

1.8

28

1650

1340

25

5.9

0.9

1.1

22

1.6

1.9

31

2140

1660

35

7.0

0.9

1.1

25

1.6

2.0

34

2590

1920

50

Compact

8.0

1.0

1.1

28

2.0

2.1

38

3450

2490

70

round

9.7

1.1

1.2

32

2.0

2.3

42

4370

3020

95

stranded

11.4

1.1

1.3

36

2.5

2.4

48

5800

3960

120

12.8

1.2

1.4

39

2.5

2.6

51

6870

4550

150

14.3

1.4

1.5

44

2.5

2.7

56

8150

5250

185

15.8

1.6

1.5

48

2.5

2.8

61

9560

5990

240

18.3

1.7

1.7

54

2.5

3.1

67

11850

7210

300

20.5

1.8

1.8

59

2.5

3.3

73

14130

8340

400

23.3

2.0

1.9

66

3.15

3.5

82

18700

10980

500

26.4

2.1

2.0

74

3.15

3.8

90

22530

12870

630

30.2

2.4

2.2

84

3.15

4.2

100

27540

15490

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
17

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

0.6/1 Kv-XLPE/SWA/PE or PVC.LV-Continuous Current Rating Factor (100%-Load)


in-air at 400C

Conductor

Aluminium

in-ground at 300C
Copper

Size

Aluminium
3

in-duct

Copper
3

conductor

Aluminium
3

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper
3

Single

or

Single

or

Single

or

Single

or

Single

or

Single

or

Core

Core

Core

Core

Core

Core

Core

Core

Core

Core

Core

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

mm

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

16

95

85

75

125

105

100

90

90

85

115

110

110

80

80

60

105

100

80

1.5

2.3

25

130

130

100

165

145

130

115

115

110

150

145

140

105

100

80

135

130

105

2.3

3.5

35

160

160

125

200

175

160

140

135

130

180

170

170

125

120

95

160

155

125

3.3

4.9

50

190

190

150

240

210

195

160

160

155

210

205

200

145

140

115

185

185

150

4.7

7.0

70

235

235

190

305

265

245

200

195

190

255

250

245

180

175

140

230

225

185

6.7

9.9

95

290

290

235

370

320

300

235

230

235

305

295

295

220

220

170

285

280

220

9.1

13.4

120

335

335

270

430

370

345

270

260

260

345

335

335

255

250

195

325

320

250

11.4

17.0

150

385

385

305

500

430

395

300

295

290

390

380

375

285

280

220

370

360

285

14.3

21.2

185

445

445

350

570

495

450

340

330

330

440

425

420

325

320

250

420

410

320

17.7

26.2

240

530

530

415

680

585

530

395

385

380

510

490

485

380

370

305

485

475

390

22.9

34.0

300

605

605

475

780

670

605

450

435

425

575

555

545

425

420

345

550

535

435

28.7

42.5

400

710

710

555

910

780

695

515

495

490

660

630

615

490

480

395

630

610

500

38.3

56.7

500

835

835

640

1060

900

795

590

565

555

750

710

690

565

545

455

715

690

560

47.0

70.9

630

980

980

740

1235

1040

900

675

645

630

855

800

770

645

625

515

815

775

630

60.6

89.4

800

1140

1140

845

1425

1190

1010

775

730

710

965

890

845

735

705

580

920

865

695

76.6

113

1000

1320

1320

945

1620

1345

1105

875

815

780

1075

980

915

830

790

640

1020

945

750

95.7

141.9

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
18

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

1.9/3.3 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor

Nominal

Thickness

thickness

of

cross

of

sectional

insulation

Nominal

Shape

Diameter

Approx.

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

(Cu)

(AL.)

separation

cable
diameter
under

armour

outer

cable

sheath

wire

wire

sheath

diameter

area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

2.0

1.1

27

2.0

2.1

37

2360

2050

25

5.9

2.0

1.1

30

2.0

2.2

40

2780

2300

35

7.0

2.0

1.2

32

2.0

2.3

43

3290

2610

50

8.0

2.0

1.2

34

2.0

2.3

45

3890

2930

70

9.7

2.0

1.3

38

2.5

2.5

50

5190

3840
4480

95

Compact

11.4

2.0

1.4

42

2.5

2.6

54

6320

120

round

12.8

2.0

1.4

45

2.5

2.8

58

7290

4980

150

stranded

14.3

2.0

1.5

48

2.5

2.9

61

8490

5590

185

15.8

2.0

1.6

52

2.5

3.0

65

9830

6260

240

18.3

2.0

1.7

57

2.5

3.2

71

12000

7370

300

20.5

2.0

1.8

62

3.15

3.4

77

14260

8470

400

23.3

2.0

1.9

69

3.15

3.6

84

18700

11000

500

26.4

2.2

2.0

76

3.15

3.9

93

22520

12920

630

30.2

2.4

2.2

86

3.15

4.2

103

15890

800

34.8

2.6

2.4

97

3.15

4.5

112

18680

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

(Cu)

(AL.)

3.8/6.6 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor

Nominal

Thickness

thickness

of

cross

of

sectional

insulation

Nominal

Shape

Diameter

Approx.

separation

cable
diameter
under

armour

outer

cable

sheath

wire

wire

sheath

diameter

area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

2.5

1.1

29

2.0

2.2

39

2540

2230

25

5.9

2.5

1.2

32

2.0

2.3

42

3030

2550

35

7.0

2.5

1.2

34

2.0

2.3

45

3510

2830

50

8.0

2.5

1.3

37

2.5

2.5

48

4160

3190

70

9.7

2.5

1.4

40

2.5

2.6

53

5500

4140
4700

95

Compact

11.4

2.5

1.4

44

2.5

2.7

57

6550

120

round

12.8

2.5

1.5

47

2.5

2.8

60

7620

5310

150

stranded

14.3

2.5

1.6

51

2.5

2.9

64

8830

5940

185

15.8

2.5

1.6

54

2.5

3.1

67

10160

6590

240

18.3

2.6

1.7

60

2.5

3.3

74

12390

7760

300

20.5

2.8

1.8

66

3.15

3.5

81

15710

9910

400

23.3

3.0

2.0

73

3.15

3.8

89

19540

11820

500

26.4

3.2

2.1

81

3.15

4.1

97

23470

13820

630

30.2

3.2

2.3

90

3.15

4.4

107

16290

800

34.8

3.2

2.5

100

3.15

4.7

118

19290

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
19

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

3.6/6 kV XLPE/SWA/PE or PVC MV-Continuous Current Rating Factor (100%-Load)


0

Conduc-

in-air at 40 C

tor

Aluminium

in-ground at 30 C
Copper

Size

Aluminium
3

in-duct

Copper
3

conductor

Aluminium

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper

Single

or

Single

or

Single

or

Single

or

Single

or

Single

or

Isolated

Isolated

Isolated

Isolated

Isolated

Isolated

Core

Core

Core

Core

Core

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

mm

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

25

126

136

87

162

175

113

112

109

87

144

140

113

98

96

64

126

82

2.36

3.58

3.58

35

152

164

108

195

211

140

132

129

108

170

166

139

116

114

81

148

146

104

3.31

5.01

50

183

199

132

235

255

170

165

153

129

200

196

167

136

134

97

174

172

125

4.72

7.15

70

228

247

158

291

316

204

189

185

152

241

237

196

165

163

115

210

209

148

6.61

10

95

276

300

197

347

382

254

223

219

186

283

279

240

195

193

141

217

246

181

8.98

13.6

120

329

354

278

422

456

357

261

255

253

335

328

325

228

224

193

293

289

248

11.34

17.2

150

371

401

312

477

517

402

291

284

281

374

366

362

254

250

215

326

323

278

14.2

21.5

185

427

461

356

546

592

457

329

322

317

420

413

407

287

283

244

367

363

313

17.5

26.5

240

508

548

427

646

702

547

380

373

371

484

478

474

332

328

286

422

420

366

22.7

34.3

300

587

635

476

743

810

608

429

422

413

542

538

528

373

370

319

472

473

407

28.4

42.9

325

615

666

517

772

842

653

446

439

437

559

556

552

418

415

338

524

526

428

30.7

46.5

400

686

743

581

858

940

734

488

483

480

610

610

607

458

457

374

572

577

472

37.8

57.2

500

793

846

665

977

1080

829

552

550

545

679

687

680

517

520

446

636

649

556

47.2

71.5

630

899

1010

779

1087

1243

956

621

625

623

749

768

765

581

589

510

701

725

626

59.5

90.1

800

1045

1164

885

1237

1406

1066

689

702

698

813

847

841

643

660

573

759

797

690

75.6

114.5

1000

1160

1307

1026

1344

1548

1211

750

774

782

866

916

923

698

727

639

806

860

754

94.5

143.1

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
20

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

6.35/11 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor

Nominal

Thickness

Approx.

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

armour

outer

cable

(Cu)

(AL.)

thickness

of

cross

of

separation

cable
diameter
under

sectional

insulation

sheath

wire

wire

sheath

diameter

Nominal

Shape

Diameter

area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

3.4

1.2

33

2.0

2.3

44

2950

2640

25

5.9

3.4

1.3

36

2.5

2.4

48

3460

2980

35

7.0

3.4

1.3

38

2.5

2.5

50

4350

3670

50

8.0

3.4

1.4

41

2.5

2.6

53

5030

4070

70

9.7

3.4

1.4

44

2.5

2.7

57

6020

4670

95

Compact

11.4

3.4

1.5

48

2.5

2.9

61

7120

5290

120

round

12.8

3.4

1.6

51

2.5

3.0

64

8190

5880

150

stranded

14.3

3.4

1.6

55

2.5

3.1

68

9430

6530

185

15.8

3.4

1.7

58

2.5

3.2

71

10810

7230

240

18.3

3.4

1.8

64

3.15

3.4

79

13860

9230

300

20.5

3.4

1.9

69

3.15

3.6

84

16220

10420

400

23.3

3.4

2.0

75

3.15

3.8

91

19920

12200

500

26.4

3.4

2.2

82

3.15

4.1

98

23700

14050

630

30.2

3.4

2.3

90

3.15

4.4

107

16430

8.5/15 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor

Nominal

Thickness

Approx.

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

(Cu)

(AL.)

thickness

of

cross

of

separation

cable
diameter
under

armour

outer

cable

sectional

insulation

sheath

wire

wire

sheath

diameter

Nominal

Shape

Diameter

area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

4.5

1.3

38

2.5

2.5

50

3850

3540

25

5.9

4.5

1.4

41

2.5

2.6

53

4400

3920

35

7.0

4.5

1.4

43

2.5

2.7

56

4960

4280

50

8.0

4.5

1.5

45

2.5

2.8

58

5660

4700

70

9.7

4.5

1.5

49

2.5

2.9

62

6640

5290
5980

95

Compact

11.4

4.5

1.6

53

2.5

3.0

66

7810

120

round

12.8

4.5

1.7

56

2.5

3.1

70

8910

6590

150

stranded

14.3

4.5

1.7

60

2.5

3.3

73

10140

7240

185

15.8

4.5

1.8

63

3.15

3.4

78

12380

8810

240

18.3

4.5

1.9

69

3.15

3.6

84

14720

10090

300

20.5

4.5

2.0

74

3.15

3.8

89

17080

11290

400

23.3

4.5

2.1

80

3.15

4.0

96

20790

13070

500

26.4

4.5

2.2

87

3.15

4.3

104

15040

630

30.2

4.5

2.4

95

3.15

4.6

113

17600

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
21

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE

12.7/ 22 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor
Nominal

Shape

Diameter

Nominal

Thickness

thickness

of

of
insulation

Approx.

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

separation
sheath

cable
diameter
under
wire

armour
wire

outer
sheath

cable
diameter

(Cu)

(AL.)

cross
sectional
area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16
25
35
50
70
95
120
150
185
240
300
400

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5
23.3

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.4
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.1
2.2

43
45
48
50
54
58
61
64
68
73
78
84

2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15
3.15
3.15

2.7
2.8
2.8
2.9
3.1
3.2
3.3
3.5
3.6
3.8
4.0
4.2

55
58
60
63
67
71
76
79
83
89
94
101

4410
5000
5600
6230
7300
8490
9550
11760
13220
15570
18040
21800

4100
4520
4920
5260
5950
6660
7230
8860
9650
10140
12240
14080

26.4

5.5

2.3

91

3.15

4.4

108

15990

Compact
round
stranded

500

19/33 kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power cable, Type XLPE/SWA/PVC
Conductor
Nominal

Shape

Nominal
Diameter

Thickness

Approx.

thickness

of

of
insulation

separation
sheath

cable
diameter
under
wire

Diameter

Thickness

Approx.

Approx.

Approx.

of

of

overall

weight

weight

armour
wire

outer
sheath

cable
diameter

(Cu)

(AL.)

cross
sectional
area
sqmm

mm

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16
25
35
50
70
95
120
150
185
240
300

4.7
5.9
7.0
8.0
9.7
11.4
12.8
14.3
15.8
18.3
20.5

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

1.6
1.7
1.7
1.8
1.8
1.9
2.0
2.0
2.1
2.2
2.3

54
57
59
61
65
69
72
75
79
84
89

2.5
2.5
2.5
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15

3.1
3.2
3.2
3.4
3.5
3.6
3.7
3.9
4.0
4.2
4.3

67
70
72
76
80
84
88
91
95
101
106

5960
6520
7100
7830
9870
11150
12360
13730
15210
17660
21210

5650
6040
6430
6800
8510
9320
10040
10840
11640
13030
14420

23.3

8.0

2.4

96

3.15

4.6

113

16350

400

Compact
round
stranded

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
22

XLPE
DIMENSIONAL
TABLE, XLPE / SWA/PVC or PE
1

6.35/11 19/33 kV-XLPE/SWA/PE.MV or PVC-Continuous Current Rating Factor (100%-Load)


0

Conduc-

in-air at 40 C

tor

Aluminium

in-ground at 30 C
Copper

Size

Single
Isolated

Aluminium
3

or

Single

Isolated

Core

in-duct

Copper
3

or

Single

Isolated

Core

Aluminium
3

or

Single

Isolated

Core

conductor

or

Single

Isolated

Core

Aluminium

Copper

1 Sec.

1 Sec.

Core

fault

fault

Copper
3

or

Single

Isolated

Core

or
4

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

Flat

Trefoil

Cable

current

current

mm

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(kA)

(kA)

16

130

115

110

100

90

85

115

110

110

90

895

85

105

105

85

80

80

70

2.3

1.5

25

170

140

135

130

118

110

150

145

145

115

110

110

135

135

115

105

105

90

3.5

2.3

35

210

185

175

160

145

135

180

170

170

135

135

135

160

160

135

125

125

105

4.9

3.3

50

245

220

210

190

170

160

210

200

200

160

155

155

190

190

160

150

145

125

7.0

4.7

70

310

275

260

240

210

200

255

250

245

200

190

190

230

230

195

180

175

150

9.9

6.7

95

375

335

310

290

260

240

305

300

295

235

230

225

290

280

240

225

220

185

13.4

9.1

120

430

385

355

335

300

275

345

335

330

270

260

260

325

320

275

255

250

210

17.0

11.4

150

495

440

375

385

340

315

390

380

375

300

290

290

365

360

310

290

285

240

21.2

14.3

185

565

500

460

440

390

355

440

426

420

340

330

325

410

410

345

330

320

270

26.2

17.7

240

670

595

540

520

460

420

510

490

485

395

385

380

480

475

400

380

370

310

34.0

22.9

300

770

680

625

600

530

485

580

555

550

450

435

430

540

535

455

430

420

355

42.5

28.7

325

613

662

413

769

839

523

446

440

408

559

556

516

418

416

298

524

526

377

30.7

46.5

400

895

790

720

700

620

565

660

630

625

515

495

495

615

610

515

495

480

405

56.7

38.3

500

1040

910

810

820

720

645

750

720

705

590

570

560

695

680

580

556

530

465

70.9

47.0

630

1210

1050

940

960

840

755

850

810

795

680

650

640

785

770

655

650

630

530

89.4

60.6

800

1395

1200

1035

1115

975

855

970

905

875

775

735

720

875

845

720

735

710

595

113.0

76.6

1000

1590

1350

1125

1290

1115

960

1080

995

950

875

825

800

960

915

785

830

795

660

141.9

95.7

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
23

XLPE
DIMENSIONAL
TABLE, Copper Conductor, XLPE / CWS/PE or PVC

38/66 kV XLPE INSULATED POWER CABLE


Copper Conductor, XLPE/CWS/PE or PVC
Conductor

Nominal
thickness

Conductor
size
(mm2)

diameter

DC
resistance
( /km)

Electrostatic
capacity
(F/km)

Diameter
(Approx
mm)
20.8

9.5

2.88

58

8110

0.0601

0.262

Compact

23.3

9.5

2.97

61

9165

0.0470

0.283

500

Round

26.4

9.5

3.08

65

10255

0.0366

0.309

630

Stranded

30.2

9.5

3.21

68

12290

0.0283

0.340

34.8

9.5

3.37

73

14110

0.0221

0.376

400

800

of cable
(Approx
mm)

Weight
of
cable
(kg/km)

Shape

300

of
insulation
(mm)

Outside
Thickness
of
jacket
(mm)

Four
1000

Segmental

38.0

9.5

3.48

76

16445

0.0176

0.404

1200

Stranded

41.7

9.5

3.61

80

18495

0.0151

0.434

Thickness
of
jacket
(mm)

diameter

Weight
of
cable
(kg/km)

DC
resistance
( /km)

Electrostatic
capacity
(F/km)

Aluminium conductor,XLPE/PE or PVC


Conductor
Nominal
thickness
Conductor

Diameter

of

size

Shape

(Approx

insulation

(mm2)

mm)

(mm)

300

Outside
of cable
(Approx
mm)

20.8

9.5

2.88

58

7145

0.1000

0.262

Compact

23.3

9.5

2.97

61

7560

0.0778

0.283

500

Round

26.4

9.5

3.08

65

8015

0.0605

0.309

630

Stranded

30.2

9.5

3.21

68

8590

0.0469

0.340

34.8

9.5

3.37

73

9330

0.0367

0.376

400

800
Four
1000

Segmental

38.0

9.5

3.48

76

10070

0.0291

0.404

1200

Stranded

41.7

9.5

3.61

80

10845

0.0247

0.434

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
24

XLPE
DIMENSIONAL
TABLE, XLPE / CWS/ PE or PVC

76/132kV XLPE Insulated Power Cable with Copper Wire screen


Aluminium Conductor, XLPE/CWS/PE or PVC
Conductor

Conductor

Shape

size
(mm2)

Diameter
(Approx

Nominal
thickness
of
insulation
(mm)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm)

Weight
of
cable
(kg/km)

DC
resistance
( /km)

Electrostatic
capacity
(F/km)

mm)

300
400

Compact

20.8

21

3.71

84

9875

0.1000

0.151

23.3

21

3.80

87

10390

0.0778

0.161

500

Round

26.4

21

3.90

89

10965

0.0605

0.173

630

Stranded

30.2

21

4.04

94

11695

0.0469

0.187

34.8

21

4.20

98

12615

0.0367

0.205

800
Four
1000

Segmental

38.0

21

4.31

102

13485

0.0291

0.217

1200

Stranded

41.7

21

4.45

107

14405

0.0247

0.231

Continuous current ratings (load factor = 100%)


In ground
Conductor Size
(mm2)

In air

In duct

Conductor

(A)

1 sec Fault
current
rating (kA)

3 sec
Fault
current
rating
(kA)

437

442

28.3

16.4

555

571

37.8

21.8

580

597

47.2

27.2

Trefoil

Flat

Trefoil

Flat

Trefoil

Flat

(A)

(A)

(A)

(A)

(A)

300

448

487

578

663

400

522

543

683

763

500

613

644

791

868

630

702

754

889

943

592

631

59.5

34.4

800

786

828

954

1037

660

705

75.6

43.6

1000

889

971

1011

1175

785

853

94.5

54.6

1200

919

1029

1144

1220

859

949

113.4

65.5

Aluminium cond.

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
25

XLPE
DIMENSIONAL
TABLE, XLPE / CWS/ PE or PVC

76/132kV XLPE Insulated Power Cable with Copper wire screen


Copper conductor , XLPE/CWS/PE or PVC
Conductor
Conductor
size

Diameter
Shape

(Approx

Nominal
thickness
of
insulation
(mm)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm)

Weight
of
cable
(kg/km)

DC
resistance
( /km)

`Electrostatic
capacity
( F/km)

(mm2)

mm)

300

20.8

21

3.71

84

11790

0.0601

0.151
0.161

400

Compact

23.3

21

3.80

87

13230

0.0470

500

Round

26.4

21

3.90

89

14155

0.0366

0.173

630

Stranded

30.2

21

4.04

94

15710

0.0283

0.187

34.8

21

4.20

98

17715

0.0221

0.205

800
Four
1000

Segmental

38.0

21

4.31

102

19860

0.0176

0.217

1200

Stranded

41.7

21

4.45

107

22060

0.0151

0.231

Continuous current ratings (load factor = 100%)

In ground
Conductor Size
(mm2)

In air

In duct

Conductor

(A)

1 sec
Fault
current
rating (kA)

3 sec
Fault
current
rating
(kA)

537

566

42.9

24.8

854

598

632

57.2

33.0

987

685

686

71.5

41.3

1063

793

833

90.1

52.0

Trefoil

Flat

Trefoil

Flat

Trefoil

Flat

(A)

(A)

(A)

(A)

(A)

300

549

591

678

763

400

618

659

779

500

710

757

894

630

819

854

992

Copper cond.

800

894

941

1047

1246

849

893

114.5

66.1

1000

996

1067

1214

1367

896

947

143.0

82.6

1200

1021

1157

1349

1394

952

996

171.7

99.1

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
26

XLPE
DIMENSIONAL TABLE XLPE/PE or PVC

93/161 kV XLPE insulated Power Cable with Copper wire screen.


Copper Conductor , XLPE/PE or PVC
Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Shape

Diameter
(Approx
mm)

Nominal
thickness
of
insulation
(mm)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm)

Weight
of
cable
(kg/km)

20.8
23.3
26.4
30.2
34.8

25
25
25
25
25

4.20
4.20
4.20
4.20
4.20

94
97
99
103
108

15305
16470
17690
19260
21270

0.0601
0.0470
0.0366
0.0283
0.0221

38.0
41.7

25
25

4.20
4.20

111
115

23420
25615

0.0176
0.0151

Compact
Round
Stranded

Four
Segmental
Stranded

DC resistance
(/km)

Electro-static
capacity
(F/km)
0.135
0.144
0.154
0.166
0.182

0.192
0.204

Continuous current ratings (load factor = 100%)


Conductor Size
(mm)

Copper cond.
300
400
500
630
800
1000
1200

In ground

In air

In duct

Conductor

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

555
633
709
822
910
1015
1091

596
664
762
859
946
1072
1162

678
779
896
997
1044
1209
1340

767
851
992
1068
1251
1372
1399

542
603
690
798
854
901
957

571
637
691
838
798
952
1001

1 sec Fault
current
rating (kA)

3 sec Fault
current
rating (kA)

42.9
57.2
71.5
90.1
114.5
143.0
171.7

24.8
33.0
41.3
52.0
66.1
82.6
99.1

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
27

XLPE
DIMENSIONAL TABLE XLPE/LC/PE or PVC

38/66 kV Lead Sheathed Cable


Copper Conductor, XLPE/LC/PE or PVC
Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Shape

Diameter
(Approx
(mm)

Nominal
thickness
of
insulation
(mm)

Thickness
of
jacket
(mm)

Thickness
of
lead
sheathed
(mm)

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

20.8
23.3
26.4
30.2
34.8

9.5
9.5
9.5
9.5
9.5

3.85
3.94
4.05
4.20
4.37

2.21
2.28
2.38
2.50
2.63

59
62
65
69
75

9.5
9.5

4.49
4.62

2.72
2.83

79
83

Compact
Round
Stranded
Four
Segmental
Stranded

38.0
41.7

DC resistance
(/km)

Electro-static
capacity
(F/km)

8340
9795
11320
13335
15840

0.0601
0.0470
0.0366
0.0283
0.0221

0.262
0.283
0.309
0.340
0.376

18395
21090

0.0176
0.0151

0.404
0.434

Continuous current ratings (load factor = 100%)


Conductor
Size (mm)

Copper cond.
300
400
500
630
800
1000
1200

In ground

In air

In duct

Conductor

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

1 sec Fault
current
rating (kA)

3 sec Fault
current
rating (kA)

457
516
681
752
920
1105
1212

531
603
704
856
987
1175
1294

593
698
787
912
1071
1218
1347

642
741
873
1011
1176
1347
1507

423
502
658
761
898
1093
1186

499
584
693
823
955
1142
1254

42.9
57.2
71.5
90.1
114.5
143.0
171.7

24.8
33.0
41.3
52.0
66.1
82.6
99.1

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
28

XLPE
DIMENSIONAL TABLE XLPE/PE or PVC

38/66 kV XLPE Insulated Lead Sheathed Cable


Aluminium conductor, XLPE/LC/PE or PVC
Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Shape

Compact
Round
Stranded

Four
Segmental
Stranded

Diameter
(Approx
(mm)

Nominal
thickness
of
insulation
(mm)

20.8
23.3
26.4
30.2
34.8

9.5
9.5
9.5
9.5
9.5

38.0
41.7

Thickness
of
jacket
(mm)

Thickness
of
lead
sheathed
(mm)

3.85
3.94
4.05
4.20
4.37

2.21
2.28
2.38
2.49
2.63

4.49
4.62

2.72
2.83

9.5
9.5

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

59
62
65
70
75

6510
7265
8155
9300
10770

79
83

18395
21090

DC
resistance
(/km)

Electro-static
capacity
(F/km)

0.1000
0.0778
0.0605
0.0469
0.0367

0.262
0.283
0.309
0.340
0.376

0.0291
-

0.404
0.434

Continuous current ratings (load factor = 100%)


In ground
Conductor
Size (mm)

Copper cond.
300
400
500
630
800
1000
1200

In air

In duct

Conductor

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

Trefoil
(A)

Flat
(A)

332
406
478
545
664
789
841

394
485
546
602
698
842
995

579
684
792
891
958
1011
1143

663
765
877
951
1043
1182
1217

313
396
457
521
656
778
824

331
410
498
577
666
821
945

1 sec Fault
current
rating (kA)

3 sec Fault
current
rating (kA)

28.3
37.8
47.2
59.5
75.6
94.5
113.4

16.4
21.8
27.2
34.4
43.6
54.6
65.5

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
29

XLPE
DIMENSIONAL TABLE XLPE/PE or PVC

76/132 kV XLPE Insulated Lead Sheathed Cable


Copper conductor, XLPE/LC/PE or PVC
Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Shape

Diameter
(Approx
(mm)

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

Four
Segmental
Stranded

38.0
41.7

Nominal
thickness
of
insulation
(mm)
21
21
21
21
21

Thickness
of
jacket
(mm)
4.74
4.84
4.95
5.09
5.26

Thickness
of
lead
sheathed
(mm)
2.93
3.01
3.10
3.22
3.35

21
21

5.38
5.52

3.45
3.56

Shape

Diameter
(Approx
(mm)

Nominal
thickness
of
insulation
(mm)

Thickness
of
jacket
(mm)

Thickness
of
lead
sheathed
(mm)

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

21
21
21
21
21

4.74
4.84
4.95
5.09
5.26

2.93
3.01
3.10
3.22
3.35

Four
Segmental
Stranded

38.0
41.7

5.38
5.52

3.45
3.56

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

87
89
93
97
102

14840
16470
18290
20625
23610

106
110

26465
29515

DC
resistance
(/km)

Electro-static
capacity
(F/km)

0.0601
0.0470
0.0366
0.0283
0.0221

0.151
0.161
0.173
0.187
0.205

0.0176
0.0151

0.217
0.231

Aluminium conductor, XLPE/LC/PE or PVC


Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

21
21

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

87
89
93
97
102

12925
13920
15105
16605
18510

106
110

20090
21865

DC
resistance
(/km)

Electro-static
capacity
(F/km)

0.1000
0.0778
0.0605
0.0469
0.0367

0.151
0.161
0.173
0.187
0.205

0.0291
0.0247

0.217
0.231

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
30

XLPE
DIMENSIONAL TABLE XLPE/PE or PVC

38/66 kV XLPE Insulated Power Cable Aluminium Wire Screen


Copper conductor, XLPE/ AWA /PE or PVC
Conductor

Nominal
thickness
of
insulation
(mm)

Diameter &
number of
aluminium
wire
(mm x N)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

DC
resistance

Electro-static
capacity
(F/km)

Conductor
size
(mm)

Shape

Diameter
(Approx mm)

300
400
500
630
800

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

9.5
9.5
9.5
9.5
9.5

2.5 x 52
2.5 x 54
2.5 x 58
2.5 x 62
2.5 x 67

2.88
2.97
3.08
3.21
3.37

59
61
64
69
74

5625
6730
7885
9370
11285

0.0601
0.0470
0.0366
0.0283
0.0221

0.262
0.283
0.309
0.340
0.376

38.0
41.7

9.5
9.5

2.5 x 70
2.5 x 74

3.48
3.61

77
81

13370
15495

0.0176
0.0151

0.404
0.434

Diameter &
number of
aluminium
wire
(mm x N)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

DC
resistance

1000
1200

Four
Segmental
Stranded

(/km)

Aluminium conductor, XLPE/ AWA / PE or PVC


Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Shape

Diameter
(Approx
(mm)

Nominal
thickness
of
insulation
(mm)

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

9.5
9.5
9.5
9.5
9.5

2.5 x 52
2.5 x 54
2.5 x 58
2.5 x 62
2.5 x 67

2.88
2.97
3.08
3.21
3.37

59
61
64
69
74

3715
4180
4695
5350
6185

0.1000
0.0778
0.0605
0.0469
0.0367

0.262
0.283
0.309
0.340
0.376

38.0
41.7

9.5
9.5

2.5 x 70
2.5 x 74

3.48
3.61

77
81

6995
7845

0.0291
0.0247

0.404
0.434

Four
Segmental
Stranded

(/km)

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
31

Electro-static
capacity
(F/km)

XLPE
DIMENSIONAL TABLE XLPE/PE or PVC

63/132 kV XLPE Insulated Power Cable with Aluminium Wire Screen


Copper conductor, XLPE/ AWA /PE or PVC
Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Diameter &
number of
aluminium
wire
(mm x N)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

DC
resistance

Shape

Diameter
(Approx
(mm)

Nominal
thickness
of
insulation
(mm)

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

21
21
21
21
21

2.5 x 80
2.5 x 80
2.5 x 80
2.5 x 80
2.5 x 80

3.72
3.80
3.91
4.04
4.21

84
87
90
94
99

8670
9825
11035
12590
14595

0.0601
0.0470
0.0366
0.0283
0.0221

0.151
0.161
0.173
0.187
0.205

38.0
41.7

21
21

2.5 x 80
2.5 x 80

4.32
4.45

102
106

16740
18940

0.0176
0.0151

0.217
0.231

Four
Segmental
Stranded

Electro-static
capacity
(F/km)

(/km)

Aluminium conductor, XLPE/ AWA / PE or PVC


Conductor
Conductor
size
(mm)
300
400
500
630
800

1000
1200

Diameter &
number of
aluminium
wire
(mm x N)

Thickness
of
jacket
(mm)

Outside
diameter
of cable
(Approx
mm

Weight
of
cable
(kg/km)

DC
resistance

Shape

Diameter
(Approx
mm)

Nominal
thickness
of
insulation
(mm)

Compact
Round
Stranded

20.8
23.3
26.4
30.2
34.8

21
21
21
21
21

2.5 x 80
2.5 x 80
2.5 x 80
2.5 x 80
2.5 x 80

3.72
3.80
3.91
4.04
4.21

84
87
90
94
99

6755
7275
7850
8575
9495

0.1000
0.0778
0.0605
0.0469
0.0367

0.262
0.283
0.309
0.340
0.376

38.0
41.7

21
21

2.5 x 80
2.5 x 80

4.32
4.45

102
106

10365
11290

0.0291
0.0247

0.404
0.434

Four
Segmental
Stranded

(/km)

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
32

Electro-static
capacity
(F/km)

XLPE
Some Of The
Various Utility Specified Cables
600/1000 V Four Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC
Conductor
Nom. Cross
sectional

Shape

area sqmm

Diameter
mm

Nominal
thickness
of
insulation
mm

Thickness
of
separation
sheath
mm

Approx.
cable diameter
under
wire
mm

Diameter
of
armour
wire
mm

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx.
weight
(Cu)
kg/km

Approx.
weight
(AL)
kg/km

25

5.9

1.1

1.0

22.1

1.6

1.9

31

3230

2590

35

7.0

1.1

1.1

24.9

1.6

2.0

34

3880

2980

50

8.0

1.2

1.1

27.9

2.0

2.1

38

4350

3070

70

9.7

1.3

1.2

32.7

2.0

2.3

43

5550

3740

95

Compact

11.4

1.3

1.3

37.0

2.5

2.5

49

6450

4010

120

round

12.8

1.4

1.4

41.0

2.5

2.6

53

7750

4660

150

stranded

14.3

1.6

1.5

45.8

2.5

2.8

58

9350

5480

185

15.8

1.8

1.6

50.6

2.5

2.9

63

11100

6340

240

18.3

1.9

1.7

57.4

2.5

3.2

71

13840

7660

300

20.5

2.0

1.8

63.4

3.15

3.4

79

16140

8420

400

23.3

2.3

2.0

72.0

3.15

3.7

88

20780

10480

6.35/11kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC
Conductor

area sqmm

mm

Nominal
thickness
of
insulation
mm

25

5.9

3.6

1.3

40

2.5

2.6

52

3640

3160

35

7.0

3.6

1.4

42

2.5

2.7

55

4140

3470

50

8.0

3.6

1.4

44

2.5

2.8

57

4740

3770

70

9.7

3.6

1.5

48

2.5

2.9

61

5660

4310
4900

Nom. Cross
sectional

Shape

Diameter

Thickness
of
separation
sheath
mm

Approx.
cable diameter
under
wire
mm

Diameter
of
armour
wire
mm

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx.
weight
(Cu)
kg/km

Approx.
weight
(AL)
kg/km

95

Compact

11.4

3.6

1.6

52

2.5

3.00

65

6730

120

round

12.8

3.6

1.6

55

2.5

3.1

68

7700

5380

150

stranded

14.3

3.6

1.7

59

2.5

3.3

72

8860

5970

185

15.8

3.6

1.8

62

3.15

3.4

77

9600

6030

240

18.3

3.6

1.9

68

3.15

3.6

83

11640

7010

300

20.5

3.6

2.0

72

3.15

3.8

88

13800

8000

400

23.3

3.6

2.1

79

3.15

4.0

95

17200

9480

19/33 kV Three Core XLPE/SWA/PVC, Wire Armoured Power Cable, Type XLPE/SWA/PVC
Conductor
Nominal
Thickness
Approx.
Diameter
of
separation
sheath
mm

cable diameter
under
wire
mm

of
armour
wire
mm

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx.
weight
(Cu)
kg/km

Approx.
weight
(AL)

area sqmm

mm

thickness
of
insulation
mm

25

5.9

8.2

1.7

60

3.15

3.4

75

5470

4980

35

7.0

8.2

1.8

63

3.15

3.5

78

6000

5330

50

8.0

8.2

1.8

65

3.15

3.5

80

6660

5700

70

9.7

8.2

1.9

69

3.15

3.7

85

7660

6310

11.4

8.2

2.0

73

3.15

3.8

89

8770

6940

Nom. Cross
sectional

95

Shape

Compact

Diameter

kg/km

120

round

12.8

8.2

2.0

76

3.15

3.9

92

9840

7520

150

stranded

14.3

8.2

2.1

79

3.15

4.0

96

11100

8210

185

15.8

8.2

2.2

83

3.15

4.1

99

12470

8210

240

18.3

8.2

2.3

88

3.15

4.3

105

14680

10050

300

205

8.2

2.4

93

3.15

4.5

110

16990

11190

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
33

XLPE
Some Of The
Various Utility Specified Cables
600/1000 V Four Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Nom.
Cross
sectional
area
sqmm

Shape

Diameter
mm

Nom.
thickness
of
insulation
mm

Thickness
of
separation
sheath
mm

Thickness
of
lead
sheath
mm

Thickness
of
separation
sheath
mm

Approx
cable
diameter
under
armour mm

Diameter
of
armour
wire
mm

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)

Approx.
weight
(AL.)

kg/km

kg/km

25

5.9

1.1

1.0

1.4

1.1

28.1

2.0

2.1

37

3820

3180

35

7.0

1.1

1.1

1.5

1.2

31.2

2.0

2.2

40

4640

3740

50

8.0

1.2

1.1

1.6

1.2

34.5

2.0

2.4

44

5730

4450

70

9.7

1.3

1.2

1.7

1.3

39.8

2.5

2.6

50

7730

5940

95

11.4

1.3

1.3

1.8

1.4

44.5

2.5

2.7

55

9550

7120

12.8

1.4

1.4

2.0

1.5

49.0

2.5

2.9

60

10480

8040

14.3

1.6

1.5

2.1

1.6

54.2

2.5

3.1

66

13680

9840

185

15.8

1.8

1.6

2.2

1.7

59.5

2.5

3.3

71

16200

11460

240

18.3

1.9

1.7

2.5

1.9

67.0

3.15

3.6

81

20900

14760

300

20.5

2.0

1.8

2.6

2.0

73.6

3.15

3.8

88

25020

17330

400

23.3

2.3

2.0

2.9

2.2

83.1

3.15

4.1

98

21360

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)

Approx.
weight
(AL.)

kg/km

kg/km

120
150

Compact
round
stranded

6.35/11 kV Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Nom.
Cross
sectional
area
sqmm

Shape

Diameter
mm

Nom.
thickness
of
insulation
mm

Thickness
of
separation
sheath
mm

Thickness
of
lead
sheath
mm

Thickness
of
separation
sheath
mm

Approx
cable
diameter
under
armour
mm

Diameter
of
armour
wire
mm

25

5.9

3.6

1.3

1.9

1.5

45.9

2.5

2.8

57

7390

6910

35

7.0

3.6

1.4

1.9

1.5

48.6

2.5

2.9

60

8230

7560

50

8.0

3.6

1.4

2.0

1.6

51.1

2.5

3.0

63

9220

8260

70
95
120

Compact
round
stranded

9.7

3.6

1.5

2.1

1.6

55.3

2.5

3.1

67

10780

9430

11.4

3.6

1.6

2.2

1.7

59.50

2.5

3.3

72

12490

10660

12.8

3.6

1.6

2.3

1.8

62.9

3.15

3.5

77

14080

11780

150

14.3

3.6

1.7

2.4

1.9

66.7

3.15

3.6

81

16710

13820

185

15.8

3.6

1.8

2.5

1.9

70.4

3.15

3.7

85

18740

15170

240

18.3

3.6

1.9

2.7

2.0

76.6

3.15

3.9

92

22100

17470

300

20.5

3.6

2.0

2.9

2.2

82.0

3.15

4.1

97

25500

19710

400

23.3

3.6

2.1

3.0

2.3

88.9

3.15

4.1

105

22860

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)

Approx.
weight
(AL.)

kg/km

kg/km

19/33 kV Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Nom.
Cross
sectional
area
sqmm

Shape

Diameter
mm

Nominal
thickness
of
insulation
mm

Thickness
of
separation
sheath
mm

Thickness
of
lead
sheath
mm

Thickness
of
separation
sheath
mm

Approx
cable
diameter
under
armour
mm

Diameter
of
armour
wire
mm

25

5.9

8.3

1.7

2.5

1.9

69.1

3.15

3.7

84

14370

13380

35

7.0

8.3

1.8

2.6

2.0

71.9

3.15

3.8

87

15470

14790

8.0

8.3

1.8

2.7

2.0

74.3

3.15

3.9

89

16660

15690

50
70

Compact
round
stranded

9.7

8.3

1.9

2.8

2.1

78.5

3.15

4.0

94

18600

17250

11.4

8.3

2.0

2.9

2.2

82.8

3.15

4.1

98

20730

18900

120

12.8

8.3

2.0

3.0

2.2

86.2

3.15

4.3

102

22630

20300

150

14.3

8.3

2.1

3.1

2.3

89.9

3.15

4.4

106

24770

21870

185

15.8

8.3

2.2

3.2

2.4

93.7

3.15

4.5

110

27080

23500

95

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
34

XLPE
Some Of The
Various Utility Specified Cables
6.35/11 kV Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Nom.
cross
sectional
area
sqmm

Shape

Diameter
mm

Nom.
thickness
of
insulation
mm

Thickness
of
separation
sheath
mm

Thickness
of
lead
sheath
mm

Thickness
of
separation
sheath
mm

Approx
cable
diameter
under
armour
mm

Diameter
of
armour
wire
mm

Thickness
of
outer
sheath
mm

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)
kg/km

Approx.
weight
(AL.)
kg/km

25

5.9

3.6

0.9

1.3

1.0

23.4

1.6

2.0

31

2620

2460

50

8.0

3.6

1.0

1.3

1.1

25.8

2.0

2.1

35

3400

3090

95

11.4

3.6

1.0

1.4

1.1

29.7

2.0

2.2

39

4480

3880

14.3

3.6

1.1

1.5

1.2

33.0

2.0

2.3

43

5590

4650

18.3

3.6

1.2

1.7

1.3

37.6

2.5

2.5

49

7680

6170

400

23.3

3.6

1.3

1.8

1.4

43.3

2.5

2.7

55

10400

7880

630

30.2

3.6

1.4

2.0

1.6

51.2

2.5

3.0

63

14400

10430

1000

39.0

3.6

1.6

2.3

1.8

61.3

3.15

3.4

75

21300

14990

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)
kg/km

Approx.
weight
(AL.)
kg/km

150
240

Compact
round
stranded

12.7/22 kV Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Approx
Nom.
Thickness Thickness Thickness
Diameter Thickness
cable
Nom.
thickness
of
of
of
of
of
diameter
cross
of
separation
lead
separation
armour
outer
Diameter
under
sectional
Shape
insulation
sheath
sheath
sheath
wire
sheath
mm
armour
area
mm
mm
mm
mm
mm
mm
mm
sqmm
25

5.9

5.7

1.0

1.4

1.1

28.2

2.0

2.2

37

3630

2460

50

8.0

5.7

1.1

1.5

1.2

30.6

2.0

2.2

40

4300

3090

95

11.4

5.7

1.1

1.6

1.2

34.5

2.0

2.4

44

5460

3880

14.3

5.7

1.2

1.7

1.3

37.8

2.5

2.5

49

7000

4650

18.3

5.7

1.3

1.8

1.4

42.4

2.5

2.7

54

8860

6170

400

23.3

5.7

1.4

1.9

1.5

48.1

2.5

2.9

60

11700

7880

630

30.2

5.7

1.5

2.2

1.7

56.0

2.5

3.2

68

15900

10430

1000

39.0

5.7

1.7

2.4

1.8

66.1

3.15

3.6

80

23040

14990

Approx.
overall
cable
diameter
mm

Approx
weight
(Cu)
kg/km

Approx.
weight
(AL.)
kg/km

150
240

Compact
round
stranded

19/33 kV Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Approx
Nom.
Thickness Thickness Thickness
Diameter Thickness
cable
Nom.
thickness
of
of
of
of
of
diameter
cross
of
separation
lead
separation
armour
outer
Diameter
under
sectional
Shape
insulation
sheath
sheath
sheath
wire
sheath
mm
armour
area
mm
mm
mm
mm
mm
mm
mm
sqmm
25

5.9

8.3

1.1

1.6

1.2

34.1

2.0

2.4

44

4830

4670

50

8.0

8.3

1.2

1.6

1.3

36.6

2.5

2.5

47

5900

5600

11.4

8.3

1.2

1.7

1.4

40.4

2.5

2.6

52

7200

6600

14.3

8.3

1.3

1.8

1.4

43.8

2.5

2.7

55

8470

7530

18.3

8.3

1.4

1.9

1.5

48.4

2.5

2.9

60

10450

8940

400

23.3

8.3

1.5

2.1

1.6

54.1

2.5

3.1

66

13480

10960

630

30.2

8.3

1.6

2.3

1.8

62.0

3.15

3.4

76

18640

14670

1000

39.0

8.3

1.8

2.6

2.0

72.1

3.15

3.8

87

25340

19030

95
150
240

Compact
round
stranded

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
35

XLPE
Some Of The
Various Utility Specified Cables
6.35/11 kV Single Core XLPE/LC/DWA/PVC, Double Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/DWA/PVC
Conductor
Nom.
Thickness Thickness Thickness
Approx cable Diameter Thickness
Nom.
thickness
of
of
of
diameter
of
of
cross
sectional
Diameter
of
separation
lead
separation
under
armour
outer
area
Shape
insulation
sheath
sheath
sheath
armour
wire
sheath
sqmm
mm
mm
mm
mm
mm
mm
mm
mm

Approx.

Approx

Approx.

overall

weight

weight

cable
diameter
mm

(Cu)

(AL.)

kg/km

kg/km

25

5.9

3.6

0.9

1.3

1.0

23.4

1.6

2.1

35

2660

2500

50

8.0

3.6

1.0

1.3

1.1

25.8

2.0

2.2

39

3490

3170

95

11.4

3.6

1.0

1.4

1.1

29.7

2.0

2.3

43

4570

3970

150

Compact

14.3

3.6

1.1

1.5

1.2

33.0

2.0

2.5

47

5690

4740

240

round

18.3

3.6

1.2

1.7

1.3

37.6

2.5

2.7

54

7800

6280

400

stranded

23.3

3.6

1.3

1.8

1.4

43.3

2.5

2.9

60

10540

8020

630

30.2

3.6

1.4

2.0

1.6

51.2

2.5

3.2

68

14610

10640

1000

39.0

3.6

1.6

2.3

1.8

61.3

3.15

3.6

82

21630

15320

Approx.

Approx

Approx.

overall

weight

weight

cable
diameter
mm

(Cu)

(AL.)

kg/km

kg/km

12.7/22 kV Single Core XLPE/LC/DWA/PVC, Double Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/DWA/PVC
Conductor
Nom.
Thickness Thickness Thickness
Approx cable Diameter Thickness
Nom.
thickness
of
of
of
diameter
of
of
cross
sectional
Diameter
of
separation
lead
separation
under
armour
outer
area
Shape
insulation
sheath
sheath
sheath
armour
wire
sheath
sqmm
mm
mm
mm
mm
mm
mm
mm
mm
25

5.9

5.7

1.0

1.4

1.1

28.2

2.0

2.3

42

3700

3540

50

8.0

5.7

1.1

1.5

1.2

30.6

2.0

2.4

44

4380

4060

95

11.4

5.7

1.1

1.6

1.2

34.5

2.0

2.5

48

5550

4950

150

Compact

14.3

5.7

1.2

1.7

1.3

37.8

2.5

2.7

54

7160

6210

240

round

18.3

5.7

1.3

1.8

1.4

42.4

2.5

2.9

59

9000

7490

400

stranded

23.3

5.7

1.4

1.9

1.5

48.1

2.5

3.1

65

11880

9350

630

30.2

5.7

1.5

2.2

1.7

56.0

2.5

3.3

74

16110

12140

1000

39.0

5.7

1.7

2.4

1.8

66.1

3.15

3.8

87

23360

17060

Thickness

Approx.

Approx

Approx.

19/33 kV Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC
Conductor
Nom.
Thickness Thickness Thickness
Approx cable Diameter
Nom.
thickness
of
of
of
diameter
of
cross
sectional
Diameter
of
separation
lead
separation
under
armour
area
Shape
insulation
sheath
sheath
sheath
armour
wire
sqmm
mm
mm
mm
mm
mm
mm
mm

of

overall

weight

weight

outer
sheath
mm

cable
diameter
mm

(Cu)

(AL.)

kg/km

kg/km

25

5.9

8.3

1.1

1.6

1.2

34.1

2.0

2.5

48

4890

4750

50

8.0

8.3

1.2

1.6

1.3

36.6

2.5

2.7

53

6030

5710

95

11.4

8.3

1.2

1.7

1.4

40.4

2.5

2.8

57

7350

6750

150

Compact

14.3

8.3

1.3

1.8

1.4

43.8

2.5

2.9

60

8660

7710

240

round

18.3

8.3

1.4

1.9

1.5

48.4

2.5

3.1

65

10630

9110

400

stranded

23.3

8.3

1.5

2.1

1.6

54.1

2.5

3.3

72

13650

11130

630

30.2

8.3

1.6

2.3

1.8

62.0

3.15

3.6

83

18980

15000

1000

39.0

8.3

1.8

2.6

2.0

72.1

3.15

4.0

94

25720

19410

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
36

XLPE
Some Of The
Various Utility Specified Cables
600/1000 V Four Core XLPE/LC/DWA/PVC, Double Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/DWA/PVC
Conductor
Nom.
cross
sectional
area
sqmm

Nom.

Thickness

Thickness

Approx
cable

Diameter

Thickness

Approx.

Approx

Approx.

thickness

of

of

of

diameter

of

of

overall

weight

weight

separation
sheath
mm

lead
sheath
mm

separation
sheath
mm

under
armour
mm

armour
wire
mm

outer
sheath
mm

cable
diameter
mm

(Cu)

(AL.)

mm

of
insulation
mm

kg/km

kg/km

25

5.9

1.1

1.0

1.4

1.1

28.1

2.0

2.3

41

4000

3360

35

7.0

1.1

1.1

1.5

1.2

31.2

2.0

2.4

44

4840

3940

50

8.0

1.2

1.1

1.6

1.2

34.5

2.0

2.5

48

5940

46660

9.7

1.3

1.2

1.7

1.3

39.8

2.5

2.8

56

8010

6220

70

Diameter

Thickness

Shape

Compact

95

round

11.4

1.3

1.3

1.8

1.4

44.5

2.5

2.9

61

9870

7440

120

stranded

12.8

1.4

1.4

2.0

1.5

49.0

2.5

3.1

66

11710

8640

150

14.3

1.6

1.5

2.1

1.6

54.2

2.5

3.3

71

14000

10160

185

15.8

1.8

1.6

2.2

1.7

59.5

2.5

3.4

77

16600

11860

240

18.3

1.9

1.7

2.5

1.9

67.0

3.15

3.8

88

21420

12570

300

20.5

2.0

1.8

2.6

2.0

73.6

3.15

4.0

95

25600

17900

400

23.3

2.3

2.0

2.9

2.2

83.1

3.15

4.4

105

21990

6.35/11 kV Three Core XLPE/LC/DWA/PVC, Double Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/DWA/PVC
Conductor
Nom.
cross
sectional
area
sqmm

Diameter

Nom.

Thickness

Thickness

Thickness

Approx
cable

Diameter

Thickness

Approx.

Approx

Approx.

thickness

of

of

of

diameter

of

of

overall

weight

weight

separation
sheath
mm

lead
sheath
mm

separation
sheath
mm

under
armour
mm

armour
wire
mm

outer
sheath
mm

cable
diameter
mm

(Cu)

(AL.)

mm

of
insulation
mm

kg/km

kg/km

25

5.9

3.6

1.3

1.9

1.5

45.9

2.5

3.0

63

7730

7250

35

7.0

3.6

1.4

1.9

1.5

48.6

2.5

3.1

66

8650

7980

50

8.0

3.6

1.4

2.0

1.6

51.1

2.5

3.2

68

9650

8680

Shape

70

Compact

9.7

3.6

1.5

2.1

1.6

55.3

2.5

3.3

73

11200

9860

95

round

11.4

3.6

1.6

2.2

1.7

59.5

2.5

3.5

77

12960

11130

120

stranded

12.8

3.6

1.6

2.3

1.8

62.9

3.15

3.7

84

15400

13070

150

14.3

3.6

1.7

2.4

1.9

66.7

3.15

3.8

88

17300

14400

185

15.8

3.6

1.8

2.5

1.9

70.4

3.15

3.9

92

19330

15760

240

18.3

3.6

1.9

2.7

2.0

76.6

3.15

4.2

98

22770

18130

300

20.5

3.6

2.0

2.9

2.2

82.0

3.15

4.3

104

20380

400

23.3

3.6

2.1

3.0

2.3

88.9

3.15

4.6

112

23600

19/33 kV Three Core XLPE/LC/DWA/PVC, Double Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/DWA/PVC
Conductor
Nom.
cross
sectional
area
sqmm

Nom.

Thickness

Approx
cable

Diameter

Thickness

Approx.

Approx

Approx.

of

of

of

diameter

of

of

overall

weight

weight

separation
sheath
mm

lead
sheath
mm

separation
sheath
mm

under
armour
mm

armour
wire
mm

outer
sheath
mm

cable
diameter
mm

(Cu)

(AL.)

mm

of
insulation
mm

kg/km

kg/km

5.9

8.3

1.7

2.5

1.9

69.1

3.15

3.9

90

14960

14480

Shape

35

Thickness

thickness
Diameter

25

Thickness

7.0

8.3

1.8

2.6

2.0

71.9

3.15

4.0

93

16130

15450

50

Compact

8.0

8.3

1.8

2.7

2.0

74.3

3.15

4.1

96

17320

16350

70

round

9.7

8.3

1.9

2.8

2.1

78.5

3.15

4.2

100

19270

17920

95

stranded

11.4

8.3

2.0

2.9

2.2

82.8

3.15

4.4

105

21400

19570

120

12.8

8.3

2.0

3.0

2.2

86.2

3.15

4.5

109

23300

20990

150

14.3

8.3

2.1

3.1

2.3

89.9

3.15

4.6

113

25500

22600

FEDERALPOWERSDNBHD|WWW.FEDERALPOWER.COM.MY
37

Anda mungkin juga menyukai