Anda di halaman 1dari 9

E2R0011-37-21

REED SWITCH ORD211


General Purpose Ultraminiature (Low-level Load 24 V Max.)

ORD211

GENERAL DESCRIPTION
The ORD211 is a small single-contact reed switch designed for general control of low-level loads less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. Features (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises an operating system and electrical circuits coaxially. Reed switches are suited to applications in radio frequency. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. External Dimensions (Unit:mm)
f0.4 MAX f2.0

MAX 10.0 35.7 0.3

APPLICATIONS OF REED SWITCHES


1. Automotive electronic devices 2. Control equipment 3. Communication equipment 4. Measurement equipment 5. Household appliances

ORD211

ELECTRICAL CHARACTERISTICS
Parameter Pull-in Value Drop-out Value Contact Resistance Breakdown Voltage Insulation Resistance Electrostatic Capacitance Contact Rating Maximum Switching Voltage Maximum Switching Current Maximum Carry Current Symbol PI DO CR Condition Rated Value Min. 10 5 150 109 Typ. Max. 40 100 0.2 1.0 24 0.1 0.3
DC AC

Unit AT AT mW VDC W pF VA V A A

(1) Drop-out vs. Pull-in

(2) Contact resistance

99.9

(Measurement length; 22 mm)

AT 50

99 95

Cumulative frequency percent


10 20 30 Pull-in 40 50 AT

40

90 80 70 60 50 40 30 20 10 5 1 0.1

Drop-out

30

20

10

40

60

80

100

mW

Contact resistance

ORD211 (3) Breakdown voltage (4) Insulation resistance


(DC 100 V)

99.9

DC : V 400
Breakdown voltage

99 95

Cumulative frequency percent 10 20 30 Pull-in 40 50 AT

300

90 80 70 60 50 40 30 20 10 5 1 0.1

200

100

10 10

10 11

10 12

10 13

10 14

Insulation resistance

(5) Electrostatic capacitance


(1 MHz) pF 0.4 Electrostatic capacitance

0.3

0.2

0.1

10

20

30 Pull-in

40

50

AT

ORD211

OPERATING CHARACTERISTICS
Parameter Operate Time Bounce Time Release Time Resonant Frequency Maximum Operating Frequency Rated Value Min. 7000 Typ. 7500 Max. 0.3 0.3 0.05 8000 500 Unit ms ms ms Hz Hz

(1) Operate time


(25 Hz : 100 AT energized) ms 0.5

(2) Bounce time


99.9 99 95

(25 Hz : 100 AT energized)

Cumulative frequency percent

90 80 70 60 50 40 30 20 10 5 1 0.1

0.4
Operate time

0.3

0.2

0.1

0.1

0.2

0.3

0.4

ms

10

20

30 Pull-in

40

50

AT

Bounce time

(3) Release time


(25 Hz : 100 AT energized)

(4) Resonant frequency


99.9

ms 15

99 95

Cumulative frequency percent

Release time

10

90 80 70 60 50 40 30 20 10 5 1 0.1

10

20

30 Drop-out

40

50

AT

7000

7500

8000

Hz

Resonant frequency

ORD211

MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2.27 kg - 10 sec) AT 60

(2) Lead tensile strength


99.9 99 95

Cumulative frequency percent


DO

50

90 80 70 60 50 40 30 20 10 5 1 0.1

Pull-in and Drop-out

40

30 PI 20

10

10 kg

Breaking load
0
mW

Contact resistance

80 CR

60

40 Before test After test

ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics

40

CR

30 DO PI

Rate of change (percent)

20

10

10

20

30

40

20

20

40

60

80

100

120 C

Temperature

ORD211 (2) Temperature cycle


(55C to 125C) AT 60 AT 60

(3) Temperature and humidity cycle


to 65C (10Cto 98% ) 80%

50

50

Pull-in and Drop-out

30 PI 20 DO 10

Pull-in and Drop-out

40

40

30 PI 20 DO 10

0
mW

0
mW

Contact resistance

60

CR

Contact resistance

80

80 CR

60

40 Before test After test

40 Before test After test

(4) High temperature storage test


(125C - 500 H) AT 60

(5) Low temperature storage test


( 40 C - 500 H) AT 60

50
Pull-in and Drop-out

50

Pull-in and Drop-out

40

40

30 PI 20 DO 10

30 PI 20 DO 10

0
mW

0
mW

Contact resistance

80 CR

Contact resistance

80 CR

60

60

40 Before test After test

40 Before test After test

ORD211 (6) Shock test


(open close)

(30 G - 11 ms) AT 60
G 1500

50

Pull-in and Drop-out

40
1000

PI 20 DO 10

Acceleration

30

Misoperation area 500

0
mW

Contact resistance

80 CR
0 10 20 30 Pull-in 40 50 60

60

AT

40 Before test After test

(7) Vibration test


(20 G - 10 to 1000 Hz) AT 60

50

Pull-in and Drop-out

40

30 PI 20 DO 10

0
mW

Contact resistance

80 CR

60

40 Before test After test

ORD211

LIFE EXPECTANCY DATA: ORD211


(%) 99.9 90 70 50 30 10 5

No failure 5 mA 1 mA 100 mA

Load conditions Voltage : 5 VDC Current : 100 mA, 1 mA, 5 mA Load : Resistive load

Cumulative failure rate

0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8

Number of operations

* Arrow indicates number of operations where test was completed

(%) 99.9 90 70 50 30 10 5

No failure 100 mA 10 mA 5 mA

Load conditions Voltage : 12 VDC Current : 5 mA, 10 mA, 100 mA Load : Resistive load

Cumulative failure rate

0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8

Number of operations

* Arrow indicates number of operations where test was completed

(%) 99.9 90

No failure 50 mA 10 mA 1 mA

Cumulative failure rate

70 50 30 10 5

Load conditions Voltage : 24 VDC Current : 1 mA, 10 mA, 50 mA Load : Resistive load

0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8

Number of operations

* Arrow indicates number of operations where test was completed

This datasheet has been downloaded from: www.DatasheetCatalog.com Datasheets for electronic components.