ORD211
GENERAL DESCRIPTION
The ORD211 is a small single-contact reed switch designed for general control of low-level loads less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. Features (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises an operating system and electrical circuits coaxially. Reed switches are suited to applications in radio frequency. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. External Dimensions (Unit:mm)
f0.4 MAX f2.0
ORD211
ELECTRICAL CHARACTERISTICS
Parameter Pull-in Value Drop-out Value Contact Resistance Breakdown Voltage Insulation Resistance Electrostatic Capacitance Contact Rating Maximum Switching Voltage Maximum Switching Current Maximum Carry Current Symbol PI DO CR Condition Rated Value Min. 10 5 150 109 Typ. Max. 40 100 0.2 1.0 24 0.1 0.3
DC AC
Unit AT AT mW VDC W pF VA V A A
99.9
AT 50
99 95
40
90 80 70 60 50 40 30 20 10 5 1 0.1
Drop-out
30
20
10
40
60
80
100
mW
Contact resistance
99.9
DC : V 400
Breakdown voltage
99 95
300
90 80 70 60 50 40 30 20 10 5 1 0.1
200
100
10 10
10 11
10 12
10 13
10 14
Insulation resistance
0.3
0.2
0.1
10
20
30 Pull-in
40
50
AT
ORD211
OPERATING CHARACTERISTICS
Parameter Operate Time Bounce Time Release Time Resonant Frequency Maximum Operating Frequency Rated Value Min. 7000 Typ. 7500 Max. 0.3 0.3 0.05 8000 500 Unit ms ms ms Hz Hz
90 80 70 60 50 40 30 20 10 5 1 0.1
0.4
Operate time
0.3
0.2
0.1
0.1
0.2
0.3
0.4
ms
10
20
30 Pull-in
40
50
AT
Bounce time
ms 15
99 95
Release time
10
90 80 70 60 50 40 30 20 10 5 1 0.1
10
20
30 Drop-out
40
50
AT
7000
7500
8000
Hz
Resonant frequency
ORD211
MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2.27 kg - 10 sec) AT 60
50
90 80 70 60 50 40 30 20 10 5 1 0.1
40
30 PI 20
10
10 kg
Breaking load
0
mW
Contact resistance
80 CR
60
ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
40
CR
30 DO PI
20
10
10
20
30
40
20
20
40
60
80
100
120 C
Temperature
50
50
30 PI 20 DO 10
40
40
30 PI 20 DO 10
0
mW
0
mW
Contact resistance
60
CR
Contact resistance
80
80 CR
60
50
Pull-in and Drop-out
50
40
40
30 PI 20 DO 10
30 PI 20 DO 10
0
mW
0
mW
Contact resistance
80 CR
Contact resistance
80 CR
60
60
(30 G - 11 ms) AT 60
G 1500
50
40
1000
PI 20 DO 10
Acceleration
30
0
mW
Contact resistance
80 CR
0 10 20 30 Pull-in 40 50 60
60
AT
50
40
30 PI 20 DO 10
0
mW
Contact resistance
80 CR
60
ORD211
No failure 5 mA 1 mA 100 mA
Load conditions Voltage : 5 VDC Current : 100 mA, 1 mA, 5 mA Load : Resistive load
0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations
(%) 99.9 90 70 50 30 10 5
No failure 100 mA 10 mA 5 mA
Load conditions Voltage : 12 VDC Current : 5 mA, 10 mA, 100 mA Load : Resistive load
0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations
(%) 99.9 90
No failure 50 mA 10 mA 1 mA
70 50 30 10 5
Load conditions Voltage : 24 VDC Current : 1 mA, 10 mA, 50 mA Load : Resistive load
0.1 0 2 3 5 7 10 5 2 3 5 7 10 6 2 3 5 7 10 7 2 3 5 7 10 8
Number of operations