1. Type of System Distribution 2. Location 3. System Size: Considering all inputs as Closed Loops 4. System Size: Considering all inputs as Open Loops 5. Maximum Communication Bus Length Standard (in m) 6. Maximum Communication Bus Length with expander (in m) 7. Maximum number of Nodes on the Communication bus 8. Maximum number of Interface on the Communication bus 9. Maximum number of Stations on the Communication bus 10. AC Voltage for the System (UPS Out) 11. Maximum static transfer time 12. DC Voltage for control system output devices 13. Type of Earthing System 14. Number of Earth Pits and type
COMMUNICATION SUBSYSTEM

: : : : : : : : : : : : : :

15. Communication topology 16. Type of Communication 17. Type of communication bus 18. Type of Bus redundancy 19. Type of protocol 20. Communication speed 21. Max nodes on the Bus 22. No. of nodes utilized
CONTROLLER & DATA ACQUISITION SUBSYSTEM : : : :

: : :

23. Subsystem: Type 24. Type of Controller 25. Number of controllers per Rack (Nest) 26. Number of Racks (Nests) per cabinet 27. Number of Controller cabinets 28. Cabinet-wise MTBF in hours
: : :

: :

/opt/scribd/conversion/tmp/scratch6249/83418108.doc

Page 1 of 4

ENCLOSURE-II 29. Cabinet-wise MTTR in hours 30. Controller Display 31. Controller Mounting 32. Scan time 33. Control cycle time 34. Number of loops per controller Available with 60% loading 35. Control Modes 36. Proportional Band tuning constant 37. Integral Rate tuning constant 38. Derivative Time tuning constant 39. Dead Time tuning constant 40. Lead Lag Time tuning constant 41. Output status during switch over 42. Output status on controller failure 43. Backup control processor type 44. Switch Over time 45. Processor cycle time 46. No. of control Blocks 47. Execution rate in cc / control block 48. Updation rate of back-up processor Per Scan 49. Type of Input module
Type of module 4-20 mA DC(2 wire) HART 4-20 mA DC(2 wire) 4-20 mA DC( Non 2 wire) 0-20 mA DC( 2 wire) 1-5V DC 0.25-1.25 V DC RTD Other Type of isolation : : No. of inputs per module : : : : : : : : : : : : : : : : :

: :

50. Type of Analog Outputs :


Type of module 4-20 mA DC(2 wire) HART 4-20 mA DC(2 wire) Type of isolation No. of outputs per module

/opt/scribd/conversion/tmp/scratch6249/83418108.doc

Page 2 of 4

ENCLOSURE-II

Other

51. Type of discrete inputs :


Type of module Potential Free Contacts 52. Type of discrete outputs: Type of module Potential Free Contacts Type of isolation No. of outputs per module Type of isolation No. of inputs per module

53. Power Supply for Transmitters 54. Maximum number of alarm settings 55. A/D Converter resolution in steps 56. D/A Converter resolution in steps 57. Load Driving capability in 58. Load Driving capability of transmitter at 24V DC 59. Maximum allowable source resistance for RTD Input Module 60. Memory type for Configuration 61. Number of Operator Stations / Group 62. Interchangeability between operator stations 63. Type of high voltage isolation 64. Type of Database 65. Data base update rate in sec 66. Users memory requirement in KB 67. Display update rate in Sec 68. Type of storage disk 69. Number of disks and capacity 70. CPU Loading in % 71. Memory Utilization in % 72. Response time for Alarm event reporting in m-sec 73. Response time for Plant overview update in sec. 74. Response time for command form operator station to field 75. Number of Engineering Stations
RTD/I Converter

: : : : : : : : : : : : : : : : : : : : : : :

76. Type of input

/opt/scribd/conversion/tmp/scratch6249/83418108.doc

Page 3 of 4

ENCLOSURE-II 77. Maximum source resistance 78. Output 79. Maximum load resistance
Signal Isolator : :

80. Input 81. Output 82. Output load driving capacity


Relays

: : : : : : : : : Dimensions in mm Width Height Depth

83. Type 84. Contact Type 85. Terminals 86. Number of contacts NO & NC 87. Relay Energised Indication 88. Panel Size and Quantity:

Description Control Cabinet Data Acquisition Cabinet AC Power Distribution Cabinet Marshalling Cabinet Trip Amplifier/ Auxiliary cabinet Electrical / Instrument Interface Operator station Engineer station Other________

Qty

Weight

/opt/scribd/conversion/tmp/scratch6249/83418108.doc

Page 4 of 4