Anda di halaman 1dari 18

www.daeyang.co.

kr

Anemometer & Anemoscope Rudder Angle Indicator Bridge Overhead Instrument System Temperature Sensor

DAEyAng ElEcTRIc
HEAD OFFICE 503, Sinpyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210

Pressure Sensor

DAEYANG INSTRUMENT

DAEYANG INSTRUMENT CO.,LTD. 502, Sinpyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210

SEOUL OFFICE 4F Subon Bldg, 112-19, Samseong-dong gangnam-gu, Seoul, Korea. Tel. 82-2-715-3492~3 Fax. 82-2-715~3495

DAEYANG ELECTRIC SUPPLY CO.,LTD. 317-2, gupyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-414-9937~9 Fax 82-51-414-9940

Printed in Korea September 2009

Published by Daeyang Electric

Designed by Daeyang Design-Team

DAEYANG INSTRUMENT

DAEYANG INSTRUMENT
Printed in Korea September 2009 Published by Daeyang Electric Designed by Daeyang Design Team

Head office
503, Sinpyeong-dong Saha-gu, Busan, Korea. Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210

Seoul office
4F Subon Bldg, 112-19, Samseong-dong Gangnam-gu, seoul, korea. Tel. 82-2-715-3492~3 Fax. 82-2-715~3495

History

Organization

DAEYANG INSTRUMENT

2010

History of Daeyang

Since

1977
1995-08 Nominated as one of the most prominent medium-sized enterprises with advanced technologies by ministry of commerce and industry 1996-12 Certified by LRQA for ISO 9001DAEYANG Electric Co., Ltd. 2000-07 Selected by Small & Medium Business Administration for Venture Company 2001-11 Awarded the Bronze Tower Order for contribution to industry by Ministry of Commerce, Industry and Energy Awarded the Export Tower by Ministry Awarded the Leading Company by Ministry of commerce, Industry and Energy 2002-11 Certified by LRQA for ISO 9001-2000 DAEYANG Electric Co., Ltd. & DAEYANG Instrument co., Ltd. 2003-02 Selected as a National Manufacture Research center by Korean Ministry of Commerce, Industry and Energy. 2003-09 Completed the development of Goniometer

2004-06 Certified by BASEEFA 2001 ATEX for explosion proof lighting equipment. 2004-09 Completed the development WICS (Wireless Interior Communication System) 2004-12 Completed the development of Ni-Rh electronic reflector 2005-05 Expanded & moved Noksan factory for Fan & Ventilation Division 2006-06 Certified as INNO-BIZ company by Small and Medium Business Administration (SMBA) 2006-11 Co-developed with KORDI an Unmanned Underwater Vehicle(UUV) for deep sea exploration at 6,000m depth in the ocean successfully 2007-1 Established design research center for interior lighting equipments of cruise in Seoul 2007-2 Completed the development of LED flat lighting equipments. 2007-5 Certified by IEC Ex for explosion proof lighting equipments. 2007-7 Certified by LCIE with ATEX Ex for explosion proof lighting equipments. 2008-7 Completed the development of new explosion proof lighting equipments for land use 2008-11 Certified by LRQA for ISO 14001DAEYANG Electric Co., Ltd. 2009-06 Developed LED lighting for indoor use

Organization
Communication System team Offshore System team Sensor System team Lighting System team Design Team LED System team Environment System team Plant System team

R&D CENTER

1977-05 DAEYANG Electric Co., Ltd. founded. 1977-12 Designated as manufacturer of marine electric equipments by Ministry of Commerce and Industry. 1984-04 Moved main office & factory to current location. (Shinpyong, Busan) 1985-09 Selected as an Excellent Exporting Company by the Korea Development Bank. 1988-03 Established an affiliated company, DAEYANG Instrument Co.,Ltd. 1988-12 DAEYANG R&D center founded. 1989-01 Established an affiliated company, DAEYANG Electric Supply Co., Ltd. 1990-11 Selected as a defense industry company by the Ministry of National Defense 1992-03 Signed a technical license agreement with WITT & SOHN, Germany 1992-04 Certified by BASEEFA for explosion proof lighting equipment

General Affairs Team Accounting Team Procurement Team

Administration Division

Planning Team MIS Team

Sales Division
Marine Sales Team 1 Marine Sales Team 2 Railroad Sales Team Military Sales Team Overseas Sales Team Seoul Sales Team Operating Control Team

Instrument Division

Instrument Design Team Instrument Production Team Assurance Team Instrument Quality

Lighting Division Elecrtical Electronic Division

Fan Division

Lighting Design Team Lighting Production Team Lighting Quality Assurance Team

Fan Design Team Fan Production Team Fan Quality Assurance Team Fan Administration Team

Electrical Design Team Electronic Design Team Electrical/Electronic Production Team Electrical/Electroni Quality Assurance Team

ww w.d aey an g. co. kr

www. da eya ng .c o. kr

Major Project

Anemometer & Anemoscope

DAEYANG INSTRUMENT

2010

TRANSMITTER

AT-US
Dimension

Weight

1.9Kg

Major Product Major Product

Indoor Light Outdoor Light Navigation Light & Signal Light Hazardous Area Light Receptacle & Switch Reefer Container Receptacle LED

385 325

Lighting

13

4 - 14 (M12 BOLT) "BOW"

AT-3N
Dimension

Weight

4.6Kg
212

290

communication-Navigation
Communication System (ICS) Refrigerated Container Monitoring System (RCMS) Power Cable Transmission System Integrated Navigation System (INS) Electro-Magnetic Speed Logs (EM-LOG)

420

121

Sensor
Temperature Sensor Pressure Sensor

120 95
BOW (CABLE GLAND OPPOSITE DIRECTION)

SPEED & DIREcTION INDIcATOR

Nautical Instrument
Anemometer & Anemoscope Rudder Angle Indicator Engine Monitoring System WIS(Weather Information System)

Degaussing/Deferming System

AI-144
Dimension

Weight

1.0Kg
73 60

Panel & Switchboard


Low & High Voltage Switchboard Starter Panel Power Distribution Panel Main Engine Control Console Emergency Switchboard Main Switchboard High Speed Rail Switchboard Battery Charging and Discharging

Fan
Axial-flow Fan Multi-blade Fan Ro/Ro Hold Ventilation System Refrigerated Hold Ventilation System
144

158 144

Max 8mm

AI-192
Dimension

Weight

1.2Kg
w ww.d aey an g. co .k r
121 109 MAX

ww w.d aey ang .c o. kr

211 192
WIND
0
DIRECTION

330

30

MAX.SPEED

300

60

192

270

m/s kts

90

240

120

210
DIM

150 180
FUCT

178

Anemometer & Anemoscope

Anemometer & Anemoscope

DAEYANG INSTRUMENT

2010

SPEcIFIcATION
INTERFAcE MEASURING RANGE Transmitter Wind speed Wind direction AccURAcY Wind speed Wind direction Power Supply Output Signal OPTION True Wind Speed / Direction Wind Speed & Direction Sensor(Standard)RS422(NMEA 0183 Ver. 2.0/3.0) 1~60m/s or 2~112kts(Digital) 0~360deg(Digital), 36LED(360), 10 steps 10m/s or less within 0.5m/s DC 24V NMEA 0183 Ver.2.0/3.0(RS 422) Wind Direction : within 1%(Full Scale)

SPEED & DIREcTION INDIcATOR

AI-F3
Dimension
360 150 170 326 170 6-6 MOUNTING HOLES

240

FITTING DIMENSION

TRANSMITTER

MODEL AI-F1 AI-F2 AI-F3 AI-S1 AI-S2 AI-S3

Included Dimmer & Power Switch

DESCRIPTION

W(kg) 7.5 7.5 7.5 9.0 9.0 9.0

Separated Dimmer or Power Switch Separated Dimmer & Power Switch Included Dimmer & Power Switch

AT-350
Dimension

Weight Using cable


ABOUT 700 ABOUT 520

7.8Kg L-MPYCY-12(8C)

Separated Dimmer or Power Switch Separated Dimmer & Power Switch

Included each one(1) indicator of FL-100S, FL-100D Combined flush mounting type. F Flush Mounting Type S Surface(Wall) Mounting Type
125 BOW 5-12 MOUNTING HOLES

ABOUT 770 ABOUT 500

FL-130S, FL-130D
Caution!
* On board installation : Align BOW mark to the head of the ship. * Shore installation : Align N mark to the north. The transmitter should be installed well ventilated location and separated from any structure by more than 2.5 meters.
MODEL FL-130D FL-130S 150 A 130 B 118 C DESCRIPTION 22 22 D 130 130 E 132 132 F 124 124 G W(kg) 1.2 1.8 AL PC 0.8 1.2

150

130

149

Indicator MODEL ( S SPEED, D DIRECTION) Separated flush mounting type Use with transformer box. Material Cover : Phenol Body : AL

Dimension
A D C

206 220

www. da eya ng .c o. kr

www. dae yan g. co .k r

B
A E F G

4 - 5.5 MOUNTING HOLES

FITTING DIMENSION

Anemometer & Anemoscope

Anemometer & Anemoscope

DAEYANG INSTRUMENT

2010

SPEED & DIREcTION INDIcATOR

AccESSORIES

FL-150S, FL-150D
MODEL FL-150D FL-200S FL-200D FL-150S A 162 212 B 183 232

DESCRIPTION D 200 250

F 136 180

G 160 160

W(kg) 3.0 3.7 5.0 5.7

AL PC 1.6 2.3 2.3 3.0

Transformer Box
A B E F

Switch

150 200

160 210

40

40 ON

DIMMER MOUNTING HOLE


10

NP C D

Indicator MODEL S SPEED, D DIRECTION Separated flush mounting type Use with transformer box. Material : Cover & Body PC or AL
Dimension
6-5.5
MOUNTING HOLES

OFF

POWER SWITCH MOUNTING HOLE


12

SHIP YARD CONSOLE 50x30 COAMING HOLES

60

60

C D E F B A

MODEL
B

A 350 170

B 250 110

C 250 200

D 300 230

E 120 150

F 3.2 3.2

W(kg) 9.0 6.0

REMARK (1) (2)

AT-TB1 AC-TB

6-M5x0.8 TAP

FITTING DIMENSION

(1) For separated indicator type(FL-130S/D, FL-150S/D, FL-200S/D) (2) For Converter Unit

OPTION : cONvERTER UNIT


For Anemometer & Anemoscope Output Signal Digital Analogue Power Source Dimension
ww w.d aey ang .c o. kr

SPEcIFIcATION
Wind Direction Wind Speed Accuracy Torque synchro-motor type Pulse Generator type Starting wind speed More than 2m/s Wind Speed Wind Direction Power Source AC 110V or 220V
w ww.d aey an g. co .k r

Wind Speed & Direction RS422 (NMEA0183 Ver 2.0/3.0) (Standard) 4~20mA at 0~60m/s, 0~360 (Option) AC 110V or 220V BOX : 260(W) X 350(L) X 185(H) Fitting : 290(W) X 250(L)

10m/s or less within 1m/s 10m/s or over, within 1%(Full Scale) within 5(Full Scale)

For Rudder Angle Indicator Output Signal RS422 ( NMEA0183 Ver 2.0/3.0 ) Option : 4~20mA

10

11

Rudder Angle Indicator

Rudder Angle Indicator

DAEYANG INSTRUMENT

2010

BLOcK DIAGRAM

TRANSMITTER

TX-472/453
MODEL TX-453 TX-472 180 A 29 B DIMENSION 16 C 220 D 115 E
CABLE GLAND RATIO (TX-RX)

W(kg) 7.7

TRANSMITTER 5C

JUNCTION BOX

220

25

16

256

135

Option

Option

1:4 Max

1:10 Max 10.6

POWER SOURCE
AC110V or 220V

Dimension
5

L (LEVER LENGTH)

10

10

5 10
A

OPTION (Signal Converter) 5C

INDIcATOR

5C INDICATOR

5C INDICATOR

5C 3C-300 INDICATOR 3C DIMMER SWITCH 3C

FE-130
MODEL FE-130 A 130 B 150 DIMENSION C D 149 130 E 132 F 124 W(kg) 1.7 1.8 AL 1.2 1.3 PC

INDICATOR

FL-130

Dimension
A D C

B
E A F G G FITTING DIMENSION

4 -5.5 MOUNTING HOLES

SPEcIFIcATION OF INDIcATOR
MODEL FE-OOO FL-OOO SE-OOO SD-OOO SL-OOO 3C-300
ww w.d aey ang .c o. kr

FL-150
DESCRIPTION SIZE
130, 150, 200 130, 150, 200 150, 200 150, 200 150, 200 300
C B D E F

MODEL FL-150 FE-200 FL-200


Dimension

Flush mounting type, without illumination device Flush mounting type, with illumination device and separated dimmer switch Surface(Wall) mounting type, without illumination device Surface(Wall) mounting type, with illumination device and combined dimmer switch Surface(Wall) mounting type, with illumination device and separated dimmer switch Ceiling mounting type, with illumination device and separated dimmer switch

FE-150

A 150 200

B 200 250

DIMENSION C D 155 158 160 210

17

5C(S)

E 162 212

F 183 232

W(kg) 3.0 5.0 5.7 3.7 AL

2.3 2.8 3.0


w ww.d aey an g. co .k r

PC

2.3

6-5.5 MOUNTING HOLES

60
A

60

6-M5x0.8 TAP FITTING DIMENSION

12

OOO Noted SIZE of indicator When ordering, please use the model number.

13

Rudder Angle Indicator

Rudder Angle Indicator

DAEYANG INSTRUMENT

2010

SD-200
MODEL SE-150 SD-150 SL-150 SE-200 SD-200 SL-200
Dimension
4-12 MOUNTING HOLE D 16

A 150

DIMENSION B C

CABLE GLAND

D 145

E 25b

W(kg) AL 4.2 5.4 4.2 5.9 6.5 5.9

180

200

20c 200 250 250 145 25b

PC 2.5 2.5 2.5 3.5 4.0 3.5

AccESSORIES

10

M10 SCREW

M10 SCREW

10

20 40 17.3 40 "L"

20

20c

B
70

9.8 M8x1.25 SCREW


PIN HOLE

M24x3 SCREW

15

32x37 HEX 40 114 3

3c-300
MODEL 3C 300
Dimension
C B

10.5

33.6

330

340

DIMENSION 439 C 45
60

HEX. NUT

175

416

W(kg) 9

2 SPLIT PIN HOLE

8 WASHER

F
A B 6-12 MOUNTING HOLE 4-14 MOUNTING HOLE E F 40
10

30 20 100 10 20 30 40 4030 A

20

40

RI-144
MODEL RI-192
www. da eya ng .c o. kr

RI-144

192

144

100

50

DIMENSION 137 C 60 D

184

110
D Max 8mm

185

138

185

138

W(kg) 1.6 1.1

D C

16

14
MOUNTING HOLE SHIP YARD CONSOLE

www. da eya ng .c o. kr

Dimension
A B
RUDDER ANGLE

31

F+1

PORT 40
DEGREE

STBD 40 30 20

30 20 10 0 10

E+1

CUTTING HOLE

MODEL
FITTING & CUTTING HOLE DIMENSION

14

JB-2303

JB-2302

280

200

220

120

DIMENSION 350 C 370 D

400

430

200

150

3.2

3.2

W(kg) 13.0 9

15

OIP (Bridge Overhead Instrument System)

OIP (Bridge Overhead Instrument System)

DAEYANG INSTRUMENT

2010

NEW and creative Design

Summary
Daeyang O.I.P (Overhead Instrument Panel) consists of various instruments, Central Dimmer and instrument Controller. The instrument panel provides information of vessel navigation. The instruments are as follows.
Clinometer Depth Indicator Rate Of Turn Indicator Gyro(Heading) Indicator Rudder Angle Indicator Ship Speed Indicator Pitch Indicator R.P.M Indicator Wind Indicator Clock CENTRAL DIMMER can give optimum brightness control, individually or whole control by the operators. INSTRUMENT CONTROLLER can change an indicator unit (m/s, Knots, meter, feet, etc.) at the remote. We do all this control to the serial(RS-422) communication. There are 144 Type(DIC-MIP-144, 1840mm x 200mm x 200mm) and 192 Type(DIC-MIP-192, 2550mm x 250mm x 250mm) of the overhead instrument panel. 18~36 VDC power requirement enables the various indicators to be powered by external batteries or DC power supply.

Dimension

DIC-OIP-192

OvERHEAD INSTRUMENT PANEL


Central Dimmer Instrument Controller
CLINOMETER DEPTH R.O.T GYRO RUDDER SPEED PITCH R.P.M WIND CLOCK

RS-422

RS-422

16

www. da eya ng .c o. kr

www. dae yan g. co .k r

CENTRAL DIMMER

INSTRUMENT CONTROLLER

17

Temperature Transmitter

Temperature Transmitter

DAEYANG INSTRUMENT

2010

PTR-LN7
Outline of Platinum Resistance Bulb
The temperature resistance characteristic of platinum wire is internationally utilized For measuring temperatures in the range of -200C to 600C. Platinum thermal resistance bulbs are known to be most suitable when used as temperature sensors which require extreme accuracy and stability.

Application For cooling fresh water, lubricating oil, fuel oil, cooling sea water temperature and low temperature flow object. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. 4. Easy maintenance 5. Replaceable internal element at fitting status

High Temperature Platinum Thermal Resistance Bulb


The platinum thermal resistance bulb is used to measure and monitor the exhaust and steam temperature of the main engine and the boiler. This resistance element provided as a unit by depositing platinum wires and internal conductors to an aluminum oxide bobbin, matches a thermocouple in mechanical strength. The platinum thermal resistance bulb allows accuracy and stability even under such a strict environment as a continuous high working temperature of 700C.
Dimension
CABLE GLAND JIS F 8801 "G"

Unit : mm

27

47

60 25 e

51

80, 100, 120, 150


7 D

D 12 13.8

S Standard : PF 3/4 Option : PF 1/2, M33, NPT 3/4 etc

e 15

Low Temperature Platinum Thermal Resistance Bulb


The platinum thermal resistance bulb is used to measure and monitor the temperatures of lubricating oil, cooling water and bearing of various engines as well as the air temperature. Since the delay characteristic(response speed) is most important factor for low temperature use this thermal resistance bulb is so designed that its resistor element keeps excellent heat which may otherwise develop in it. The adoption of double protection tube does not affect the characteristic, maintaining the same characteristics as those of protection tube types.

200, 250, 300, above 300

15
7

Operating Range : 0 ~ 200C

PTR-LD

Application For fuel oil, feed water, cooling water temperature and medium temperature flow object. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. 4. Easy maintenance 5. Replaceable internal element at fitting status

Standard Type of Platinum Resistance Bulb


MODEL PTR-LN7 PTR-L, LD PTR-S, SD PTR-MN PTR-FN PTR-M(F)
Note We can make and supply dual element type RB sensor according to your order.

Operating Range() 0 ~ 200 0 ~ 350 0 ~ 600

Material of Protection Tube

Remark

Operating Class Temerature() -200 ~ 600 B A

Tolerance() ( 0.15 + 0.002 | t | ) ( 0.30 + 0.005 | t | )

Dimension
CABLE GLAND JIS F 8801 "G" 27 47 (60) L

PTR-M, MB 0 ~ 200

SUS 304 (SUS316 For Cooling Sea Water)

1. Norminal Resistance Pt 100(at 0) 2. Wire connecting terminal

51

25 e 5 15 Do 12 "D"

80, 100, 120, 150 above 300 200, 250

Do/D or D 17 23/17 22

S Standard : PF 3/4 Option : PF 1/2, M33, NPT 3/4 etc

Unit : mm

20

Note According to DIN RULE R100/R0 = 1.3851 R0 : Resistance Value at 0 C R100 : Resistance Value at 100 C t : measuring temperature

PTR-SD

0 7

Operating Range : 0 ~ 350C PTR-L : without protecting well

Temperature Characteristic Curve of Platinum Resistance Bulb


Electric Resistance ratio (Rt/Ro) 3.2 2.8 2.4 2.0 1.6 1.2 0.8 0.4 0 -250 -200 -100 0 100 200 300

Note Ro : Resistance at 0 C Rt : Resistance at t C

Application Use for exhaust gas system and high temperature steam system. Vibration-resistant and shockresistant at high temperature place. Features 1. Excellent measurement accuracy 2. Rapid response speed 3. High durability against vibrations and shocks at high temperature place 4. Maintenance and checks are easy
Unit : mm

" Do"

51

15

18

D1 D

www. da eya ng .c o. kr

www. da eya ng .c o. kr

Dimension
CABLE GLAND JIS F 8801 "G" 27 47 (70) "L"

80, 100, 120, 150 180, 200, 250, 300 350, 400, 450, 600

D1 12

Do/D 23/17 23/20 22

S 23/17 Standard : PF 3/4 Option : PF 1/2, M33, NPT 3/4 etc

f 25

25 " e " 5

15

25

35

0 7

400

500 600 Temperature(tc)

Operating Range : 0 ~ 600C PTR-S : without protecting well

19

Temperature Transmitter

Temperature Transmitter

DAEYANG INSTRUMENT

2010

PTR-A11

Application For indoor, freezing chamber and ambient temperature. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. Operating Range : -50 ~ 100C

PTR-FN

Application Use for H.F.O Tank Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy 5. The element is replaceable Operating Range (C) : 0~200 CLASS : B

Dimension
CABLE GLAND

222 80 L 100

Dimension
CABLE GLAND JIS F 8801 "G"
19

Flange Selection Flange (JIS TYPE)


27 47 60 t L

Class 5K25A
P.C.D D

PCD 75

D 95

DIA of Holes

80

51

25 15

10K25A 90 5K40A 10K40A 105 95

125 120 140

4 - 12 10 4 - 19 14 4 - 15 12 4 - 19 16

PTR-MN

Application For stern tube bearing oil temperature. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. 4. Replaceable internal element at fitting status 5. Minimum bending radius is 80mm. Remark Standard length of protecting tube -3, 5, 7, 9, 11m Mounting parts are specially designed and should be specified by the user.
110 L

PTR-M(F)

17
7 0

2- 7

Application Use for H.F.O Tank Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : 0~200 CLASS : B

Dimension
CABLE GLAND JIS G 80

7 0

12

44

20

44

Operating Range : 0 ~ 200C

Dimension
2-7 CABLE GLAND JIS F 8801 "G" 27 47 80 t L

Flange Selection Flange (JIS TYPE)

Class 5K25A

PCD 75

D 95

PTR-M(PcO) & PTR-M(TP)


www. da eya ng .c o. kr

DIA of Holes

Application For intermediate shaft bearing oil, thrust pad, piston cooling oil and main bearing temperature. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. 4. Excellent flexibility. Remark Standard length of cable : 5, 8m Mounting parts are specially designed and should be specified by the user. Operating Range : 0 ~ 200C

D P.C.D

51

10K25A 90 5K40A 10K40A 105 95

125 120 140

4 - 12 10 4 - 19 14 4 - 15 12 4 - 19 16
www. da eya ng .c o. kr

0 7

20

21

Temperature Transmitter

Temperature Transmitter

DAEYANG INSTRUMENT

2010

PTR-LD(LNG)

Application Use for LNG Cargo Tank Spray , Liquid , Vapor Line Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : -200~100 CLASS : A

PTR-M(LNG)

Application Use for LNG Cargo Tank Bulk Head Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : -200~100 CLASS : A

Dimension
CABLE GLAND JIS F 8801 "G" 38 50 40 "L"

Dimension

135

140 120

60 45 25 32

"e" 20

NP L TO BE SPECIFIED IN MEASURING LIST

15 D

2-9

R3/4

Outline of Thermocouple
The thermocouple is a detector to measure temperature of water, oil, air, exhaust gas and so on by utilizing the characteristic of thermo electromotive force(potential) according to temperature difference generated between two being joined different metal wire. These thermocouples are so designed that they will sufficiently function in marine engines Under several environmental conditions.

PTR-M-1(LNG), PTR-M-2(LNG)
Application Use for LNG Cargo Tank Barrier Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : -200~100 CLASS : A

McA-D & 2D

4.8

8 0

Application For exhaust gas of engine & boiler, steam and high temperature flow object. Vibration-resistant and shock-resistant position at high temperature. Features 1. High accuracy 2. Rapid response time 3. High durability against vibration. 4. Easy maintenance. 5. Replaceable internal element at fitting status

Dimension
80 E (CABLE LENGTH) 14 "e" L

135 145

DO/D 6.4

S NPT1/4

e 14

Standard Model of Thermocouple


MODEL MCA-D Operating Material of Range() Protecting well 0 ~ 600 SUS 304 Remark With Amplifier & Compensation or Extension Cable L 80, 100, 120, 150 D1 12 15 15 Do/D 23/17 23/20 22 S Standard : PF 3/4 Option : PF 1/2, M33, M20 etc e

180, 200, 250, 300 Above 300

6.4

25

6C FOR M4 TERMINAL TO BE SEPARATED

"S" THREAD

PROTECTING TUBE

MCA-D must be used with amplifier and compensation or extension cable.

51

22

333~1200

-40~333

2.5

15

"Do"

D1

0.075 | t |

www. da eya ng .c o. kr

www. da eya ng .c o. kr

Operating Range : 0 ~ 600C MCA-S : without protecting well Dimension

Tolerance of Thermocouple(Type K)
Operating Temperture() 375~1000 -40~375 Class 1 Tolerance() 1.5 0.004 | t |

CABLE GLAND 27 47 (70) "L"

25 5

t : measuring temperature

23

Temperature Transmitter

Temperature Switch(Handling item)

DAEYANG INSTRUMENT

2010

McA-S

Application Use for Cylinder Liner Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : 0~600 CLASS : 2

RT TYPE
DANFOSS A17-712.11 DANFOSS A17-711.11

Model RT 101 RT 107 RT 101 RT 106 RT 13

2, 3, 5, 8, 10 2, 3, 5, 8, 10 5. 8. 10 2, 3 5 2, 3

Capillary tube (m)

L(mm) 80 110 76 86 Capillary tube(m) 2 2

RT13, RT10, RT107, RT101

RT106

Dimension
CABLE GLAND 35 50 20 40 175 50 "S" M16x1.5 54 4

Model RT 101
RT 101 & RT 107 : screw = PF3/4 Maker : Danfoss A/S

Code No. 017 - 5003 17 - 5097

Setting range(C) Max permissible temp(C) 25 - 90 -30 - 0 150 300

RT 13

RT 107 RT 106

017 - 5135

10

017 - 5048

017 - 5050

70 -150 20 - 90
104 83 Pg13.5

215 120

5 2

31

7 2

PROTECTING TUBE

Dimension Application Use for Cylinder Liner Features 1. Excellent measurement accuracy 2. Rapid response speed. 3. High durability against vibrations. 4. Maintenance and checks are easy Operating Range (C) : 0~600 CLASS : 2
25

McA-MB

28

68

61

9.5 8.5 110 24 8.5 5

122

KPS TYPE
Dimension
COMPENSATING WIRE FLEXIBLE TUBE 116 90 68 3.2 41 81 11 79 103 120

40

61

54

100

CAPILLARY TUBE

Dimension
13 2 - 7

M18 x 1.5

CAPILLARY TUBE

Pg13.5

14 e

SPRING

S M16x1.5

PROTECTING TUBE

29 44 81

84 22 74

JK-2c-60T
Specification 1. Ambient temperature : 0~70C 2. Input signal : Electromotive force of K type 3. Output signal : DC 4~20mA 4. Max. load impedance : 250 5. Accuracy : 1.0% 6. Power source : DC 24V ( +10%, -15% ) 7. Color of case : RAL 6018 8. Measuring range : 0~600C

Model KPS 76 KPS 77 KPS 79 KPS 80 KPS 81 KPS 83

Code No. 060L3102 060L3113

Setting range(C) -10 ~ 30 20 ~ 60 50 ~ 60 70 ~ 120 60 ~ 150 100 ~ 200

Differential range (C) 3 ~ 10 3 ~ 14 4 ~ 16 4.5 ~ 18 5 ~ 25 6.5 ~ 30

Max permissible temp (C) 80 130 200 200 250 300

Cap tube (m) 2 2 2 2 2 5 5 5 5 2

L(mm) 75, 110 75, 110 75, 110 75, 110 75, 110 110 110 110 110 75
www. dae yan g. co .k r

/ 0-600 C

MEASURING EQUIPMENT ADJUST SPAN

THERMOCOUPLE AMPLIFIER

DAEYANG INSTRUMENT CO., LTD.

SERIAL NO.

IN

THERMO COUPLE

INPUT / RANGE

OUTPUT

24

www. da eya ng .c o. kr

POWER

24V DC

4
-

3
OUT +

060L3120 060L3123 060L3105

LOAD

TYPE JK-2C-60T

4 - 20 mA DC

K TYPE

ZERO JK-2C-60T

Thermocouple amplifier

060L3135 060L3109

060L3107

060L3131

060L3129

79

+
3 1

25

Temperature Switch(Handling item)

DAEYANG INSTRUMENT

2010

471 TYPE
Dimension
6.5 G1/2 SW17 SW17 40
THERMOSTAT

KPS TYPE
Dimension
116 90 68 7 6

SW27

3
G1/2 G MAX. 6 19 64 12

103 79

120

PG13.5 86 100

41

Model 471.2323 471.2331 471.2353

Range in(C) 20...110 20...150 40...300

Sensor max(C) 115 165 330

Switch type no. 23 26 23 26

Switching diff.k(C) 2.0 3.5 2.0 5.0

Sensor Range(C) G=65 G=110 G=130 G=150

Cable Range(L) L=1000 L=3000 L=5000 L=8000 (option)

KPS 31, 33 58

KPS 35, 37, 39 30

KPS 43, 45, 47 40

81

60 G 3/8A

29 35 44 68

G1/4

Max. housing temperature : -30... +70C Pressure proofness of protection tube : max. 25bar
Maker : Trafag AG

23 26

7.0 7.0

Model KPS 31 KPS 33 KPS 37 KPS 35

Code No. 060-3109 060-3103 060-3106 060-3100

Setting range Pe (bar) 0 -> 2.5 0 -> 3.5 6 -> 18 0 -> 8

Adjustable fixed differential (bar) 0.1 0.2

Permissible operating pressure Pe (bar) 10 6

Max. test pressure (bar) 10 6

Pressure connection G 3/8A G 3/8A G 1/4

PRESSURE SWITcH (HANDLING ITEM)

KPS 39 Model

060-3107

10 -> 35 Setting range Pe (bar) 4 -> 40 1 -> 10

0.85 ~ 2.5 2.0 ~ 6 Adjustable diff(bar) 2.2 -> 1.1 0.7 -> 2.8 Permissible over pressure (bar) 120 120

0.4 ~ 1.5

45

22

12

53

27

12

G 3/8A G 1/4

Code No. 060-3121 060-3120

RT TYPE
Dimension
23 110 83 PG13.5 x 2
(Cable outdia : 6-14mm)

74

KPS 47

KPS 45

KPS 43

Max. test pressure (bar) 180 180

Min. bursting pressure (bar) 240 240

Pressure connection G 1/4 G 1/4

060-3122

6 -> 60

3.5 -> 1.7

120

180

240

G 1/4

MBc5100
Dimension
24 5

127 100

93

62

25.5

8.5

95

Model RT 112 RT 110

Code No. 017-5191 017-5291

Regulation range (bar) 0.1 - 1.1 1 - 10 -1 - 0 0.2 - 3

Adjustable mechanical (bar) 0.07 - 0.16 0.09 - 0.4 0.3 - 1.3 1.2 - 4 1-4 0.08 - 0.25

Max. operating pressure(bar) 7

Max. test pressure(bar) 8 Model Regulation range(bar) -0.2 - 4 1 - 10 5 - 20 5 - 40 1-6

15 30

9.8 G1/4 73 84

15 20 30 In
1 3 2

CABLE GLAND

+ 5.5 15

Out NO Out NC

26

www. da eya ng .c o. kr

www. dae yan g. co .k r

RT 121 RT 200 RT 117 RT 113 RT 5 RT 116

017-5215 017-5237

017-5203

Adjustable diff(bar) 0.15 - 0.45 0.30 - 2.00 0.40 - 2.50 1.00 - 7.00

Max. operating Press(bar) 15 150

Min. bursting pressure(bar) 30 300

017-5295 017-5296

017-5255

0.2 - 6 10 - 30 0 - 0.3 4 - 17

0.25 - 1.2

22 42 0.4

25 47 28

MBC5100.2431 MBC5100.3231 MBC5100.3641

MBC5100.2211

MBC5100.1211

0.01 - 0.05

0.5

27

Diff pressure switch(Handling item)

Diff pressure switch(Handling item)

DAEYANG INSTRUMENT

2010

DIFF PRESSURE SWITcH (HANDLING ITEM)

cAS TYPE
Dimension
116 90 68 2-7 3

920 TYPE
Dimension
106 91 36 TERMINAL : 1 - 2 BREAK ON RISE IN PRESSURE TERMINALS : 1 - 3 MAKE ON RISE IN PRESSSURE 2 1 3 ** INPUT VOLTAGE : MAX. 250V/AC, DC

P 90 69

55

120 103 79

1/4 BSP 41 81 44 68 35 6

Model Model
920.2374 920.2376 920.2377 920.2378

Code No. 060-3130


1)

Pressure Connection 1/4 BSP

Ambient Temp. -25 - +70

Temperature of mediumC
1)

Diff Range bar 0.2 - 2.5

Diff (Fixed)bar 0.1

Range
-0.6...3.4 0...4 0...6 0...10 1...16

Differential
0.16 0.16 0.16 0.4 0.4

Press. Actuator
9.31 9.33 9.33 9.35 9.35

size
X Y

CAS 155

-25 - +100

Max. Operation Pressure LP side bar 8

Max. test Pressure bar 22

Weight(kg) 1.5

93 93 93 93 93

45 45 45 45 45

Maker : Danfoss A/S

For water and seawater, Max. 80C

1950
Dimension
17/64(6.75) 3-1/2 (88.9) RANGE ADJUSTMENT SCREW

RT TYPE

920.2379 Dimension

110 83

74

4-7/8 (123.8)

LP

PG13.5 x 2
(Cable outdia : 6-14mm)

127 100

NPT1/2 ELEC. CONDUIT CONNECTION


93 24

5-7/16 (138.1)

62

5
62 HP

NPT1/8 (HIGH) PRESSURE PORT

8.5

1-11/16 (42.9)

VENT DRAIN PLUG NPT1/8 PRESSURE PORT

1-7/16 (36.5)

3/8 (9.53)

Model RT266AL
www. da eya ng .c o. kr

Code No. 1700081

Operation range (bar) -1 -6 -1 -9 -1 -10 -1 -18 -1 -36 -1 -31

Regulation range P (bar) 0.1 - 0.1 0.1 - 1.5 0 - 0.3 0.5 - 4 1.5 -11 1 -6 0.5 - 6 0 - 0.9

Mechanical differential(bar) 0.05 0.1 0.035 0.3 0.5

Max. Operation Pressure(bar) 7 11 22 42

Max. test Pressure (bar) 8 13 25 47

Weight(kg)

Model 1950-02-2S 1950-00-2F 1950-0-2F

Regulation range inch WTR(mbar) 0.03 - 0.1 (0.075 - 0.25) 0.07 - 0.15 (0.17 - 0.37) 0.15 - 0.5 (0.37 - 1.25) 0.4 - 1.6 (1.0 - 3.99)

Min. Set Point 0.025 (0.06) 0.04 (0.1)

Approximate Dead Band at 0.05 (0.12)

Max. Set Point

Pressure connection

Weight(kg)

RT263AL RT262AL RT262A RT262A

1700045 1700043 1700025 1700027 1700048 1700021 1700023 1700024

0.1 (0.25) 0.15 (0.37) 0.3 (0.75) 0.4 (1.0)

0.05 (0.12) 0.15 (0.37)

www. da eya ng .c o. kr

RT260AL RT260A RT260A

1.1

1950-1-2F 1950-5-2F 1950-10-2F 1950-50-2F

1.4 - 5.5 (3.49 - 13.7)

0.2 (0.49) 0.4 (1.0)

1/8 Female NPT

1.5

RT260A

28

RT265A

1700027

-1 -36

3.0 - 11 (7.47 - 27.4) 4.0 - 20 (9.96 - 49.8)

Maker : Danfoss A/S

0.4 (1.0)

0.5 (1.25)

0.6 (1.49)

29

Pressure Transmitter (Handling item)

Pressure Transmitter (Handling item)

DAEYANG INSTRUMENT

2010

PRESSURE TRANSMITTER (HANDING ITEM)

SMP-MB
Dimension
93 54 3-5.5 HOLE 55 6

EMP-2 TYPE
Dimension
116 100 90 68 6 7

Meiyo 63 78 80 93

117 103 79

120

PF3/8 CABLE GLAND "G" SEE THE SPECIFICATION TABLE 29 35 44 37

41

81

68

Electric connection

Electric connection

PRESSURE TRANSMITTER
Vp-N 4-20mA

+ DC 4-20mA LOAD MAX. 550 AT POWER SUPPLY DC24V

18

+ POWER - SUPPLY

+ -

P N T

RL

+ 24 V d.c. Vmax. 36V d.c. Imax. ~ 50mA Pmax. ~ 2W

RL

40-200mV

Technlcal data and ordering


Techanical data and Ordering

Pressure in Mpa(kg/cm2)
Pressure Range
0~0.1 (0~1)

Technlcal data and ordering


Pressure in bar
Operating pressure Pe bar -1 - 5 0-1 -1 - 1.5 0.2 - 1 Test pressure Pe bar 35 5 Min burst pressure Pe bar 200 100 Code no. EMP 2 084G2100 G 1/2 A G 3/8 A

Power supply

DC 24V(-25% ~ +30%) 500mv p-p less DC 4~20mA 550 at 24V DC 500g for 1ms to IEC 60068-2-27 IP 54 JIS F 8801 15c Makers standard Connection port : SUS, case : ALDC 0.53Kg -20 ~ 70, compensation temperature 5 ~ 55 3~30Hz amplitude 1.13mm and 30~300Hz acceleration 4G according to IEC 60068-2-6. The requirements of the ship classification societies are up to 100Hz, acceleration 4G Extended specifications by prior arrangement. Complies with the standard for industrial apparatus EN 61000-6-2. The standard contains tests for the following : HF fields, main Transmitted HF, voltage transients, electrostatic immunity, supply Voltage variations, low-frequency radiation and transient protection In accordance with Germanish Lloyd. Complies with standard EN 61000-6-3

Pressure in kg/cm2
Operating pressure Pe kg/cm2 -1 - 5 0-1 -1 - 1.5 0.2 - 1 Test pressure Pe kg/cm2 35 5 Min burst pressure Pe kg/cm2 200 100 Code no. EMP 2 084G2130 G 1/2 A G 3/8 A

Power supply ripple Output signal Load resistance Accuracy Enclosure Cable gland Color of case 084G2157 084G2235 Material Weight Operating temperature

30

-1 - 9

0 - 400

0 - 250

0 - 160

0 - 100

0 - 60

0 - 40

0 - 25

0 - 16

0 - 10

0 - 10

0-6

0-6

0-4

0 - 2.5

0 - 1.6

20

600

375

260

200

120

80

50

32

60

20

60

18

3.2

3.2

3.2

400

1600

1000

640

400

400

400

400

400

400

400

400

400

200

200

100

100

100

084G2120

084G2118

084G2117

084G2116

084G2115

084G2114

084G2113

084G2112

084G2111

084G2110

084G2109

084G2108

084G2107

084G2106

084G2105

084G2104

084G2103

084G2102

084G2101

084G2207 084G2209 084G2211 084G2213

084G2206

-1 - 20

0 - 400

0 - 250

0 - 160

0 - 100

0 - 50

0 - 40

0 - 25

0 - 15

0 - 10

0 - 10

0-6

0-6

0-4

0 - 2.5

0 - 1.6

50

600

375

260

200

120

80

50

32

60

20

60

18

3.2

3.2

3.2

400

1600

1000

640

400

400

400

400

400

400

400

400

400

200

200

100

100

100

084G2154

084G2148

084G2147

084G2146

084G2145

084G2144

084G2143

084G2142

084G2141

084G2140

084G2139

084G2138

084G2137

084G2136

084G2135

084G2134

084G2133

084G2132

084G2131

084G2158 084G2179

-0.1~ 0.4 (-75cm Hg~4)

-0.1~ 0

0~35

0~25

0~15

0~10

0~7

0~5

0~3.5

0~2.5

0~2

0~1.5

0~1

0~0.6

0~0.4

0~0.3

0~0.2

(-75cm Hg~0)

(0~350)

(0~250)

(0~150)

(0~100)

(0~70)

(0~50)

(0~35)

(0~25)

(0~20)

(0~15)

(0~10)

(0~6)

(0~4)

(0~3)

(0~2)

084G2159 084G2169

084G2149

Vibration resistance

118

www. da eya ng .c o. kr

www. da eya ng .c o. kr

Noise immunity

Noise emission

31

Pressure Transmitter (Handling item)

Pressure Transmitter (Handling item)

DAEYANG INSTRUMENT

2010

MBS5100
Dimension

92.5

25.5

CABLE GLAND

5.5 9.8 15 20 30

15 30

G1/4 73 84

15

Electric connection

MAKER : YAMATAKE
TYPE MODEL JTA922A JTA940A JTG940A Measuring Span 4 ~ 104kPa A (30 ~ 780mmHg A) 35 ~ 3500kPa A (0.35 ~ 35kgf/cm2 A) 35 ~ 3500kPa A (0.35 ~ 35kgf/cm2) 0.7 ~ 14MPa (7 ~ 140kgf/cm2 A) 0.7 ~ 42MPa (7 ~ 420kgf/cm2) 0.75 ~ 100kPa (75 ~ 10160mmH2O) Setting Range 0 ~ 104kPa A (30 ~ 780mmHg A) 0 ~ 3500kPa A (0 ~ 35kgf/cm2 A) -100 ~ 3500kPa (-1 ~ 35kgf/cm2) -0.1 ~ 14MPa (-1 ~ 140kgf/cm2) -100 ~ 42MkPa (-1 ~ 420kgf/cm2) -100 ~ 100kPa (-10160 ~ 10160mmH2O) -100 ~ 700kPa (-1 ~ 7kgf/cm2) Working Pressure Range 0.01 ~ 104kPa A (0.1 ~ 780mmHg A) 0.01 ~ 3500kPa A (0.1mmHg A ~ 35kgf/cm2 A) 2.0 ~ 3500kPa (15mmHg A ~ 35kgf/cm2) 2.0kPa ~ 14MPa (15mmHg A ~ 140kgf/cm2) 2.0kPa ~ 42MPa (15mmHg A ~ 420kgf/cm2) 2.0kPa A ~ 14MPa (15mmHg A ~ 140kgf/cm2) 2.0kPa A ~ 14MPa (15mmHg A ~ 140kgf/cm2)

1 2

40-200mV + RL -

+ - UB

Absolute Pressure

Model MBS5100.1611 MBS5100.1811 MBS5100.2011 MBS5100.2211 MBS5100.2411 MBS5100.2611

Regulation range(bar) 0-4 0 - 10 0 - 16 0 - 25 0 - 40 0-6

Max. operating Press(bar) 8 20 50 80

Min. burst pressure(bar) 50

Gauge Pressure

JTG960A JTG980A JTD920A

100 800

Differential Pressure

JTD930A JTD960A

35 ~ 700kPa (0.35 ~ 7kgf/cm2)

0.25 ~ 14MPa (2.5 ~ 140kgf/cm2)

-100 ~ 14MkPa (-1 ~ 140kgf/cm2)

SMART TYPE TRANSMITTER


MAKER : HONEYWELL
TYPE Absolute Pressure MODEL STA922 STA940 STG944 www. da eya ng .c o. kr Gauge Pressure STG974 STG98L STD924 Differential Pressure STD930 STD974 RANGE 0 ~ 1,040mbar A

You can easily select the analogue or digital transmission format through the smart field communicator A : Absolute

ELEcTRIc TYPE PRESSURE & TEMPERATURE INDIcATOR


MODEL
B A C E 17

SYM A B
F

KAE11 90 110 70 20 20 102 M5

KAN11 85.5 104.5 66.5 19 15 102 M5

DVF11 90 110 70 20 15 102 M5

DVF11E 90 110 85 24 15 102 M5

MKH110TP 90 110 85 24 15 104 M5

MKH110FPEL 90 110 80 23 www. dae yan g. co .k r 30 104 M5

0 ~ 35bar 0 ~ 210bar 0 ~ 415bar 0 ~ 1,000mbar 0 ~ 7bar 0 ~ 210bar

A B

0 ~ 35bar A

C D E F G

32

You can easily select the analogue or digital transmission format through the smart field communicator maker: Honeywell

KAE-11 : For Pressure & Temperature, Input Signal : 4~20mA KAN-11 : For Temperature, Input Signal : Resistance 3 wire, Power source : DC24V DVF-11 : For Pressure & Temperature, Input Signal : 4~20mA DVF-11E : For Pressure & Temperature, Input Signal : 4~20mA, with Illumination(AC110V) MKH-110TP : For pressure, Input Signal : 4~20mA MKH-110FPEL : For Pressure & Temperature, Input Signal : 4~ 20mA, with Illumination(AC110V)

33

Pressure Transmitter (Handling item)

certification

DAEYANG INSTRUMENT

2010

AccESSORIES

cERTIFIcATION

7 1

4 2

1. Chamber 2. Pipe Syphon 3. 3Way test valve 4. Gauge valve 5. Damper 6. Gauge Connector ( 8, 10, 10.5, 15 etc. ) 7. 2-Way manifold valve ( For smart pressure transmitter ) 8. 3-Way manifold valve ( For smart pressure transmitter ) Material of accessories : Brass, SUS, Steel except for 2 & 3-Way manifold valve 2 & 3-Way manifold valve : SUS 316

34

www. da eya ng .c o. kr

www. dae yan g. co .k r

35

Anda mungkin juga menyukai