ABB Control Oy
Protection
SPEM offers protection in the following ways: Thermal Overload Protection with complete Thermal Capacity Memory (TCM) Start-up Current Protection Under Current Protection Unbalance Protection - phase unbalance - phase failure - incorrect phase sequence Earth Fault Protection Self Supervision Fail Safe Operation
Applications
The SPEM relay is the ideal answer to problems requiring more versatile or accurate protection for a motor than can be offered by a standard thermal overload relay. SPEM relays can be used for protecting low voltage squirrel cage (AC) motors 1). Use of SPEM motor protection relay: - helps in extending life time of motor - helps in optimizing motor size - helps in planning maintenance work - protects the drive from mechanical damage
S00790A
EMC-tested
Tested according to EMC-directive No: 89/336/EEC.
1)
S00789A
In the following cases please contact the manufacturer: - Frequency Converters - Star-Delta Starters - Soft Starters - Power Factor Correction Banks (PFC)
ABB Control Oy
S00792A
Thermal capacity
The microprosessor is continuously calculating the thermal capacity available in the motor: 1) starting 2) overloading 3) stand still (even after tripping) Tripping takes place, when the thermal capacity of motor is exceeded i.e. motor current is higher than 1.05 x full load current I. Refer to the thermal tripping characteristics below.
100%
Tripping
1)
S00793A
3) 2)
time 3h 2h 1h 30min 20min 10min 5min 3min 2min 1min 40s 30s 20s 10s 5s 3s 2s 1s 1.05s 1 2 3 4 5 6
I/I~ 0
I/I~ 0
Without prior load (Cold curve) Cooling time-constant = 4 x the heating time-constant.
ABB Control Oy
100%
40%
S00794A
t
Restart inhibit
After tripping, if there is less than 60 % of motor capacity available, SPEM does not allow a new start until the motor cools down (restart inhibit). In this case, a new start is possible approximately after 30 s.
Provides protection against a sudden loss of loads e.g. Dry running pumps Broken conveyer belts
This feature can be selected by means of switch S2 (I OFF/ON) on the front panel of the SPEM relay (see page 6).
%
100 90 80 70 60
Typical off load current for large and medium sized motors.
S00786A
50 40 30 20 10 0
55
Tripping is activated if the current stays between 12...55 % of full load current (I) longer than 10 s.
12
Unbalance Protection
Provides protection against: 1. Phase unbalance 2. Phase failure 3. Incorrect phase sequence
S00797A
ABB Control Oy
In case of complete phase failure or incorrect phase sequence, the tripping time is 6 s. Otherwise according to the curve shown.
20 10
The time-lag of the unbalance/ singlephasing unit.
0 0
10
20
30
40
50 (%)
Unbalance percentage
Provides an indication of a defect in motor winding. Motor can remain in operation if necessary from process point of view. The maintenance of the motor can be postponed to an appropriate time.
By means of switch S3 (I0 / TRIP) on the front panel of SPEM, it is possible to select either tripping and signalling or only signalling in case of earth fault failure. If only signalling is selected, there will be no tripping of the SPEM relay but the signalling contact (9-10) of the relay operates. In case a tripping function is selected and the SPEM relay has tripped, it will be automatically reset after 200 ms when automatic reset is selected from switch S1 (Reset A/M). Time lag 1 second for eliminating short time failures. The tripping level for the earth fault current can be set with the potentiometer I0 /In on the front panel of the SPEM relay.
S00788A
Self Supervision
The functions of the electronic circuits are continuously supervised by means of a hardware watchdog. In case of an internal fault, contact 9-10 closes giving an alarm and contact 11 - 12 remains in its position keeping the motor circuit closed, and enabling continuation of the process.
ABB Control Oy
S00796A
t (s) 30
Presetting
t6 time
Adjustability from 2 s to 30 s. Information from motor manufactures.
Switches S1...S8
S1
Automatic or manual resetting
SPEM
MADE IN FINLAND
12 OK 11
~ 0
>
I I< I0
MOTOR PROTECTION RELAY t 6 x (s) 10 20 Reset A/M I< OFF / ON Io / Trip 2 30 2 I 0 / I 0n 4 0.4 0.5 I~ = 0 8 0.3 +60 16 [% In] 0.2 0.6 32
The SPEM is always automatically reset, when tripping takes place caused by thermal overload or start-up current protection. Otherwise either manual or automatic resetting. Manual resetting by operating S1 from manual position to automatic position and back to manual position. S2
Undercurrent protection OFF/ON
Earth fault
(SPEM40_ and SPEM50_ types). Adjustability from 20 % to 60 % of rated zero sequence (SPEM40_) or residual (SPEM50_) current. See table on the page 8.
Operation of dipswitches to ON-position by moving to the right. Selectable from 60 % up to 122 % with accuracy of 1 %. Steps are: 60 % (fixed) 32 % 16 % 8% 4% 2%
Setting of full load current preset in percentage (I %) and adjustement of current transfomers.
The functions (except earth fault protection) are based on full load current, which is the maximum allowed continuous on load current of the motor. The presets, in percent, can be calculated from the following formula: I ICT Example: ABB motor M2BA 315 SMC 4B3 Pn = 160 kW, In = 282 A, 400 V used with 5 % overload allowed by the manufacturer Full load current: I = 282 A x 1.05 = 296 A SPEM type selected from the table on page 9 SPEM40B310 (with earth fault protection) setting value: 296 A I = x 100% = 95 % 310 A Select switches S8 and S4. Fixed 60% no need to select. (60 + 32 + 2) % = 94 % < 95 % The t6 time for the motor: M2BA 315 SMC 4B3 is 15 s (information from motor manufacturer)
I % = I % I ICT
x 100%
= full load current preset in percentage = maximum allowed continous on load current = full load current = rated primary current of current transformer
ABB Control Oy
SPEM
MADE IN FINLAND
12 OK 11
~ 0>
I I< I0
MOTOR PROTECTION RELAY t 6 x (s) 10 20 Reset A/M I< OFF / ON Io / Trip 2 30 2 I 0 / I 0n 4 0.4 0.5 I~ = 0 8 0.3 +60 16 [% In] 0.2 0.6 32
Earth fault Steady red light on the lower LED Automatic or manual reset The earth fault indication cancels when the motor is restarted or if the fault disappears
I %
t6 / s OFF/ON I %
Steady light
Middle LED
UNBALANCE - phase interrupt - single phase - incorrect phase sequence EARTH FAULT
I %
I0 / I n % Alarm Trip -
Lower potentiom. S3 S3 -
Steady light
"OK" OFF
Upper LED
ABB Control Oy
Thermal overload unit Setting of full load current I Resolution of full load setting Setting of maximum stall time at 6 times In, t6x Cooling time constant at zero current (standstill) Undercurrent unit Operating value Operating time Resetting time Phase unbalance unit Basic sensitivity, fully stabilized to phase current levels between In and 4 x In , typical value Operating time at pickup level Operating time at full unbalance Resetting time Earth fault unit1) Zero-sequence / residual2) current setting I0 Operating time Resetting time Auxiliary power supply Uaux Supply voltage on standard relay (operation range 0.85 x Umin . . . 1.10 x Umax) Power consumption Output contact ratings Rated voltage, make and break Make and carry for 1 s Continuous load Breaking capacity Environmental conditions Specified ambient service temperature Transport and storage temperature range
1 2
12 . . . 55 % of I 10 s 1s
30 % 30 s 6s 1s
SPEM_B_ SPEM_C_
230 V AC 30 A 5A 5 A AC
) In types SPEM 40_ and SPEM 50_. ) Rated residual current in types SPEM 50_ is 1 A (with continuous withstand capability 2 A and thermal withstand for 1 second 40 A)
In -range 4,5 ... 63 A 63 ... 111 A 111 ... 186 A 186 ... 310 A 240 ... 400 A 300 ... 500 A
ABB Control Oy
SPEM30B060 SPEM30B105 SPEM30B185 SPEM30B310 SPEM30B400 SPEM30B500 SPEM40B060 SPEM40B105 SPEM40B185 SPEM40B310 SPEM40B400 SPEM40B500 SPEM50B060 SPEM50B105 SPEM50B185 SPEM50B310 SPEM50B400 SPEM50B500
60 105 185 310 400 500 60 105 185 310 400 500 60 105 185 310 400 500
4.5...63 63...111 111...186 186...310 240...400 300...500 4.5...63 63...111 111...186 186...310 240...400 300...500 4.5...63 63...111 111...186 186...310 240...400 300...500
106 106 102 100 100 100 106 106 102 100 100 100 106 106 102 100 100 100
1 1 1 1 1 1
1SCA022388R3210 1SCA022388R5090 1SCA022388R5170 1SCA022388R5250 1SCA022388R5330 1SCA022388R5410 1SCA022388R6140 1SCA022388R6220 1SCA022388R6310 1SCA022388R6490 1SCA022388R6570 1SCA022388R6650 1SCA022388R6730 1SCA022388R6810 1SCA022388R6900 1SCA022388R7030 1SCA022388R7110 1SCA022388R7200
S00789A
SPEM30C060 SPEM30C105 SPEM30C185 SPEM30C310 SPEM30C400 SPEM30C500 SPEM40C060 SPEM40C105 SPEM40C185 SPEM40C310 SPEM40C400 SPEM40C500 SPEM50C060 SPEM50C105 SPEM50C185 SPEM50C310 SPEM50C400 SPEM50C500
60 105 185 310 400 500 60 105 185 310 400 500 60 105 185 310 400 500
4.5...63 63...111 111...186 186...310 240...400 300...500 4.5...63 63...111 111...186 186...310 240...400 300...500 4.5...63 63...111 111...186 186...310 240...400 300...500
106 106 102 100 100 100 106 106 102 100 100 100 106 106 102 100 100 100
1 1 1 1 1 1
1SCA022388R5500 1SCA022388R5680 1SCA022388R5760 1SCA022388R5840 1SCA022388R5920 1SCA022388R6060 1SCA022388R7380 1SCA022388R7460 1SCA022388R7540 1SCA022388R7620 1SCA022388R7710 1SCA022388R7890 1SCA022388R7970 1SCA022388R8010 1SCA022388R8190 1SCA022388R8270 1SCA022388R8350 1SCA022388R8430
ABB Control Oy
S00790A
4.5 ... 7.5 7.2 ... 12.0 12.0 ... 20.0 18.0 ... 36.0 36.0 ... 63.6
8 5 3 2 1
1pc
S00787A
2pc
3pc
10
ABB Control Oy
L1 L2 L3
F1 F2 F3
L1
F4
3 4
5 6
K1
2
A B C D E F
S1 S2
9 10 11 12
T3 T2
S00785A
TRIP
S1 S2
SIGNAL
SPEM
T1
S1 S2
S1 O S2 I H1 1 H2
13
21 22 13
U aux
M1
V1 U1
K1
14 1 14 A1
U2
M 3~
V2
W1
W2
K1
2
A2
L1 L2 L3
F1 F2 F3
L1
F4
3 4
5 6 S1
K1
2
T3
S2
A B C D E F
9 10 11 12
TRIP
T2
S00784A
S1 S2
SIGNAL
SPEM
T1
S1 S2
V1 U1
S1 O S2 I
H1
1 2
21 22
U aux
13
13
M1
K1
14
1
U2
M 3~
V2
W1
H2
14 A1
W2
K1
2
A2
ABB Control Oy
11
SPEM _60...400
77,5
SPEM_500
77,5
EN 50022
115
115 EN 50022
42
192
203
22 111 44
S00780A
228
58 76 192 O6
58 21
82 245 82
82 O7
MOTOR PROTECTION RELAY t 6 x (s) 20 Reset A/M I< OFF / ON Io / Trip 30 2 I 0 / I 0n 4 0.4 0.5 I~ = 0 8 0.3 +60 16 [% In]
SPEM
32
66 55
43
0.6
60 55
MOTOR PROTECTION RELAY t 6 x (s) 20 Reset A/M I< OFF / ON Io / Trip 30 2 I 0 / I 0n 4 0.4 0.5 I~ = 0 8 0.3 +60 16 [% In]
SPEM
32
MADE IN FINLAND
OK
I I<
12
11
I0
~ 0
MADE IN FINLAND
>
OK
I I<
12
11
I0
~ 0
0.2
10
55
60
80
100
0.2
10
>
0.6
CERTIFIED E
IRONMEN NV
L SYSTEM TA
ISO 14001
ISO 9001
SFS
ABB Control Oy
P.O. Box 622 FIN - 65101 VAASA Finland Tel +358 10 22 4000 Fax +358 10 22 45708
The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations.
12
ABB Control Oy